Loading...
20-103097-SE04661A-FCDs-07-13-2020v1VICINITY MAP N NOT TO SCALE LOCAL MAP SITE N NOT TO SCALE APPLICANT: T-MOBILE USA INC. 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 Know what's below. CALL before you dig. CALL AT LEAST TWO WORKING DAYS BEFORE YOU DIG USA Nor t h DIG ALERT HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION, HANDICAP ACCESS REQUIREMENT(S) DO NOT APPLY SITE PARCEL NUMBER: 0104550010 JURISDICTION: CITY OF FEDERAL WAY SITE ADDRESS: LATITUDE AND LONGITUDE: ALDERBROOK DIV NO 06 PROPERTY OWNER: ZONING: LEGAL DESCRIPTION:COUNTY: KING COUNTY R.O.W / RS5.0 N 47° 18' 20.4", W 122° 21' 38.7" (BASED ON 1A SURVEY DATED: 04/21/2015) TAME & EVELYN CONTORAVDIS 33003 20TH PL SW FEDERAL WAY, WA 98023 EXISTING USE: NEW USE: UNMANNED TELECOMMUNICATIONS FACILITY TOTAL LEASE AREA: ± 150 sq. ft. 33003 20TH PL SW FEDERAL WAY, WA 98023 T-1 TITLE SHEET DRIVING DIRECTIONS 1. HEAD SOUTH ON NORTH CREEK PKWY TOWARD NORTH CREEK TRAIL 2. TURN RIGHT ONTO NE 195TH ST 3. TURN LEFT ONTO THE I-405 SOUTH RAMP TO RENTON 4. MERGE ONTO I-405 S 5. TAKE THE EXIT ONTO I-5 SOUTH TOWARD PORTLAN 6. TAKE EXIT 143 FOR S 320TH ST TOWARD FEDERAL WAY 7. TURN RIGHT ONTO S 320TH ST. 8. TURN LEFT ONTO 21ST AVE. SW 9. TURN LEFT ONTO SW 330TH ST. 10. TAKE THE 1ST RIGHT ONTO 20TH PL SW DESTINATION WILL BE ON THE RIGHT CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING LOCATIONS, CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME DO NOT SCALE DRAWINGS APPROVALS APPROVAL SIGNATURE DATE PROJECT MANAGER T-MOBILE RF ENGINEER SITE ACQUISITION CONSTRUCTION MANAGER SITE OWNER STARTING FROM 19807 NORTH CREEK PARKWAY NORTH, BOTHELL, WA 98011: SITE UNMANNED TELECOMMUNICATIONS FACILITY ALDERBROOK /PSE /CONTORA 33003 20TH PL SW FEDERAL WAY, WA 98023 SE04661A REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF CODE COMPLIANCE T-MOBILE DEVELOPMENT MANAGER T-MOBILE CONSTRUCTION MANAGER T-MOBILE OPS MANAGER T-MOBILE REGULATORY REVIEW T-MOBILE PROJECT MANAGER WASHINGTON STATE CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. THE WASHINGTON STATE BUILDING CODE IS COMPRISED OF THE MODEL CODE EDITIONS BELOW WITH WASHINGTON STATE AMENDMENTS: - 2015 INTERNATIONAL BUILDING CODE - 2015 INTERNATIONAL RESIDENTIAL CODE - 2015 INTERNATIONAL MECHANICAL CODE - 2015 INTERNATIONAL FIRE CODE - 2015 UNIFORM PLUMBING CODE - 2015 IECC/WASHINGTON STATE ENERGY CODE - LOCAL CODES AND AMENDMENTS FCC NOTE: THIS WIRELESS COMMUNICATION FACILITY COMPLIES WITH FEDERAL STANDARDS FOR RADIO FREQUENCY IN ACCORDANCE WITH THE TELECOMMUNICATION ACT OF 1996 AND SUBSEQUENT AMENDMENTS AND ANY OTHER REQUIREMENTS IMPOSED BY STATE OR FEDERAL REGULATORY AGENCIES. T-MOBILE PERMITTING SITE INFORMATION PROJECT DESCRIPTION BASED ON RFDS VERSION 7 DATED: 06/26/2020 x REMOVE (2) EXISTING ULTRASITE CABINET IN SHELTER x REMOVE (1) EXISTING POWER RACK x REMOVE (1) EXISTING SAR-A ROUTER FROM RACK x REMOVE (1) EXISTING FSMF FROM CABINET x REMOVE (3) EXISTING FRIA FROM CABINET x REMOVE (2) EXISTING FRIE FROM CABINET x REMOVE (2) EXISTING FXFC FROM CABINET x REMOVE (3) EXISTING FRLB FROM UNISTRUT x REMOVE (6) EXISTING DIPLEXERS FROM WALL x REMOVE (3) EXISTING TRIPLEXERS FROM WALL x REMOVE (3) EXISTING ANTENNAS (SBNHH-1D65C-SR) x REMOVE (9) EXISTING TMAS ON TOWER x REMOVE ALL EXISTING COAX CABLES x INSTALL (4) NEW (FFVV-65C-R3-V1) ANTENNAS x INSTALL (3) NEW (AEHC) ANTENNAS x INSTALL (4) NEW AHLOA ON TOWER x INSTALL (4) NEW AHFIG ON TOWER x INSTALL (1) NEW WALL MOUNT x INSTALL (9) NEW CROSSOVER PLATES x INSTALL (10) NEW MOUNTING PIPES x INSTALL (3) NEW HCS 2.0 PENDANTS ON TOWER x INSTALL (3) NEW HCS 2.0 TRUNKS 150' x INSTALL (3) NEW HCS 2.0 JUNCTION BOXES ON WALL x INSTALL (2) NEW CABINETS (1 HPL3, 1 LB3) x INSTALL (1) NEW CSR IXRe ROUTER IN HPL3 x INSTALL (2) NEW VOLTAGE BOOSTER IN HPL3 x INSTALL (2) NEW AMIA IN HPL3 x INSTALL (2) NEW ASIB IN AMIA x INSTALL (2) NEW ASIK IN AMIA x INSTALL (3) NEW ABIA IN AMIA x INSTALL (5) NEW ABIL IN AMIA x INSTALL (3) NEW ABIC IN AMIA x INSTALL (1) NEW CAC PANEL WITH GEN PLUG AND CUBE ON WALL x REMOVE (2) EXISTING FSME FROM CABINET SHEET DESCRIPTION SHEET INDEX T-1 TITLE SHEET A-1 A-2 A-3 SITE PLAN ENLARGED SITE PLAN T-2 NOTES & LEGEND A-4 ELEVATIONS A-5 ELEVATIONS ANTENNA MOUNTING SPECIFICATIONS G-1 GROUNDING PLANS G-2 GROUNDING DETAILS RF-1 RF DETAILS ANTENNA PLAN A-3.1 EQUIPMENT PLAN A-8 RF-2 RF DIAGRAM R DETAILSA-7 DETAILSA-6 TOWER OWNER: PUGET SOUND ENERGY PO BOX 97034 BELLEVUE, WA 98004 A-9 HELIAX FIBER FEED PENDANT CONNECT E-1 ELECTRICAL NOTES E-2 ELECTRICAL PLAN, PANEL SCHEDULE, & DIAGRAMS E-3 ELECTRICAL DIAGRAMS ARCHITECTURE: SITE ACQUISITION:CONSTRUCTION MANAGER: ENGINEER: CONTACT INFORMATION ZONING & PERMITTING: TECHNOLOGY ASSOCIATES EC, INC OFFICE: (425) 269-5561 CONTACT: RENATA FAYTEN EMAIL: renatasoffice@gmail.com 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 TECHNOLOGY ASSOCIATES EC, INC OFFICE: (425) 269-5561 CONTACT: RENATA FAYTEN EMAIL: renatasoffice@gmail.com 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 RF ENGINEER: T-MOBILE USA INC. 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 EMAIL: OlsenJohn.Ong1@T-Mobile.com CONTACT: OLSEN JOHN ONG TECHNOLOGY ASSOCIATES EC, INC MOBILE: (206) 446-5677 EMAIL: alec.langton@taec.net CONTACT: ALEC LANGTON 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 TECHNOLOGY ASSOCIATES EC, INC OFFICE: (801) 463-1020 x 2107 EMAIL: joel.hartman@taec.net CONTACT: JOEL R. HARTMAN, PE 7896 SOUTH HIGHLAND DRIVE, STE. 200 COTTONWOOD HEIGHTS, UT 84121 PUGET SOUND ENERGY PO BOX 97034 BELLEVUE, WA 98004 CONTACT: TIMOTHY GASSER PHONE: 206-947-0335 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF EXPANSIONEXP. GROUND FAULT CIRCUIT INTERRUPTER GLOBAL POSITIONING SYSTEM G.F.I. GLB.(GLU-LAM) GPS GLUE LAMINATED BEAM F.S. FTG. G. GA. GI. FT.(') GALVANIZE(D) GAUGE FOOTING FOOT(FEET) FINISH SURFACE GROWTH (CABINET) FINISH(ED) FDN. F.O.W. F.O.C. F.O.M. F.O.S. FLR. FACE OF WALL FACE OF STUD FOUNDATION FLOOR FACE OF MASONRY FACE OF CONCRETE FAB. EXT. FIN. F.G. F.F. EXST.(E) FINISH FLOOR FINISH GRADE EXTERIOR FABRICATION(OR) EXISTING THK. TEMP. THICK(NESS) TEMPORARY ANTENNA CABLE COVER ASSEMBLY BARE TINNED COPPER WIRE ELECTRICAL METALLIC TUBING CLG. CEILING DIAGONALDIAG. ELECTRICALELEC. E.N. EMT. EQ. ENG. ELEV. EQUAL ENGINEER EDGE NAIL ELEVATOR DWG. DWL. DIM. EL. EA. EACH ELEVATION DOWEL(S) DRAWING(S) DIMENSION CONTINUOUSCONT. DBL. d D.F. DIA. DEPT. DEPARTMENT DOUGLAS FIR DIAMETER PENNY (NAILS) DOUBLE CLR. COL. CONC. CONN. CONST. CLEAR CONSTRUCTION COLUMN CONCRETE CONNECTION(OR) ARCHITECT(URAL) B/U CAB. C.I.P. CANT. B.O.F. BTCW. CABINET BOTTOM OF FOOTING CAST IN PLACE CANTILEVER(ED) BACK-UP CABINET BLK. B.N. BM. BLDG. BLKG. AWG. BEAM BLOCK BUILDING BLOCKING BOUNDARY NAILING AMERICAN WIRE GAUGE A.F.F. ABOVE FINISHED FLOOR ALT. ANT. APPRX. ARCH. ALUM. A.F.G. ALTERNATE ALUMINUM ANTENNA ABOVE FINISHED GRADE APPROXIMATE(LY) ABV. A.B. ADD'L ACCA ANCHOR BOLT ABOVE ADDITIONAL OPENINGOPNG. REFERENCEREF. SIMILARSIM. SQ. S.S. STL. STD. SPEC. STRUC. SQUARE STEEL SPECIFICATION(S) STANDARD STRUCTURAL STAINLESS STEEL RGS. SHT. SCH. REQ'D. REINF. SHEET REQUIRED SCHEDULE RIGID GALVANIZED STEEL REINFORCEMENT(ING) POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PERSONAL COMMUNICATION SERVICES POWER PROTECTION CABINET P.S.F. P.S.I. P.T. PWR. QTY. RAD.(R) QUANTITY RADIUS PRESSURE TREATED POWER (CABINET) PLY. P/C PCS PPC PRC PLYWOOD PRECAST CONCRETE PRIMARY RADIO CABINET LONG(ITUDINAL) (N) MTL. O.C. N.T.S. MISC. NO.(#)NEW METAL NUMBER ON CENTER MISCELLANEOUS NOT TO SCALE M.B. MAX. MIN. MFR. MAS. MECH. MAXIMUM MINIMUM MECHANICAL MACHINE BOLT MANUFACTURER MASONRY ISOLATED COPPER GROUND BUSICGB. INT. L.F. L. L.B. IN.(") LB.(#) INTERIOR INCH(ES) POUND(S) LAG BOLTS LINEAR FEET (FOOT) HDR. HT. HGR. GRND. GROUND HEADER HEIGHT HANGER 1ABBREVIATIONS 2LEGEND ABBREVIATION DEFINITION ABBREVIATION DEFINITION ABBREVIATION DEFINITION 4GENERAL NOTES UNLESS NOTED OTHERWISE WEIGHTWT. CL PL PLATE CENTERLINE W V.I.F. WD. W.P. W/ U.N.O. WITH WOOD WEATHERPROOF WIDE(WIDTH) VERIFY IN FIELD UNDERWRITERS LABORATORY TYP. T.O.S. T.O.W. U.L. U.G. T.O.P. TYPICAL UNDER GROUND TOP OF STEEL TOP OF WALL TOP OF PLATE (PARAPET) T.N. T.O.C. T.O.F. T.O.A. TOE NAIL TOP OF CURB TOP OF ANTENNA TOP OF FOUNDATION TMA TOWER MOUNTED AMPLIFIER RRU. RADIO REMOTE UNIT T-2 NOTES & LEGEND GENERAL FIRE NOTES: 1. THIS FACILITY IS EXEMPT FROM HANDICAP REQUIREMENTS PER 2015 INTERNATIONAL BUILDING CODE SECTION 1103.2.9. THIS FACILITY IS NON-OCCUPIABLE SPACE AND ENTERED ONLY BY SERVICE PERSONNEL. THIS SPACE IS NOT FOR HUMAN OCCUPANCY. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO SUBMITTING BIDS, AND PROCEEDING WITH ANY WORK. 3. THE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY ERRORS, OMISSIONS, OR DISCREPANCIES AS THEY MAY BE DISCOVERED IN THE PLANS, SPECIFICATIONS, & NOTES PRIOR TO STARTING CONSTRUCTION. INCLUDING BUT NOT LIMITED BY DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERRORS, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE METHOD OF CORRECTION SHALL BE APPROVED BY THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT. 4. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR HAS THE RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE PLANS, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR OR SUBCONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGE TO THE UTILITIES CAUSED DURING THE EXECUTION OF THE WORK. CONTACT USA DIG ALERT @ 800-227-2600 5. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO PROPOSED OR EXISTING SURFACES, STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE PROPERTY OWNER. THE CONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGED AREAS. 6. A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL CONSTRUCTION SETS REFLECT THE SAME INFORMATION AS THE APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF DOCUMENTING ALL AS-BUILT CHANGES, REVISIONS, ADDENDA, OR CHANGE ORDERS. THE CONTRACTOR SHALL FORWARD THE AS-BUILT/HIRED DRAWINGS TO THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT AT THE CONCLUSION OF THE PROJECT. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE WORK IS IN PROGRESS UNTIL THE JOB IS COMPLETE. 8. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE TEMPORARY POWER, WATER, AND TOILET FACILITIES AS REQUIRED BY THE PROPERTY OWNER OR GOVERNING AGENCY. 9. ALL CONSTRUCTION THROUGH THE PROJECT SHALL CONFORM TO THE LATEST I.B.C. AND ALL OTHER GOVERNING CODES, INCLUDING THE THE MOST RESTRICTIVE CODE SHALL GOVERN. 10. THE CONTRACTOR AND SUBCONTRACTOR SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS INCLUDING ALL OSHA REQUIREMENTS. 11. WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING OR BRACING SHALL BE PROVIDED WHERE THE STRUCTURE OR SOIL HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT. 12. THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK, USING HIS PROFESSIONAL KNOWLEDGE AND SKILLS. HE IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCING AND COORDINATING ALL PORTIONS OF THE WORK UNDER THE PROJECT. 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTIONS WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR AUTHORIZED AGENT. CONTRACTOR SHALL OBTAIN THE PERMIT AND MAKE FINAL PAYMENT OF SAID DOCUMENT. 14. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE. DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCES. 15. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR SUPPORTS FOR INSTALLATION OF ITEMS INDICATED ON THE DRAWINGS. 16. THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL OR U.L APPROVED MATERIALS TO FILL/SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. GENERAL NOTES 17. PROPOSED CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN FORM, TEXTURE, MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS. 18. THE CONTRACTOR IS TO PROVIDE PORTABLE FIRE EXTINGUISHERS HAVING A MINIMUM 2A:10-B:C RATING WITHIN 75FT. OF TRAVEL TO ALL PORTIONS OF THE CONSTRUCTION AREA. (2015 INTERNATIONAL BUILDING CODE 906.1.1 AND SECTION 906.3.1) 19. MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AVAILABLE AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR APPROVING THE RESULTS. 20. ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE. 21. ALL DEBRIS AND REFUSE IS TO BE REMOVED FROM THE PROJECT. PREMISES SHALL BE LEFT IN A CLEAN BROOM FINISHED CONDITION AT ALL TIMES. 22. BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE NOTIFIED PRIOR TO ANY GRADING AND CONSTRUCTION EFFORT AS MANDATED BY THE GOVERNING AGENCY. 23. ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY STANDARDS. IF A CONTRACTOR HAS A QUESTION REGARDING THEIR EXACT MEANING THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT SHALL BE NOTIFIED FOR CLARIFICATIONS. 24. SITE CONTRACTOR TO CALL DIG ALERT (1-800-227-2600) TO LOCATE ANY AND ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. 25. ALL FACILITIES TO BE INSTALLED ARE UNMANNED. NO (E) PARKING SPACES WILL BE USED OR REMOVED BY THIS PROJECT. 26. PRIOR TO THE ISSUANCE OF ANY CONSTRUCTION PERMITS, THE APPLICANT SHALL INCORPORATE ANY CONSTRUCTION BEST MANAGEMENT PRACTICES NECESSARY TO COMPLY WITH THE CITY'S MUNICIPAL CODES INTO THE CONSTRUCTION PLANS OR SPECIFICATIONS. 27. PRIOR TO THE ISSUANCE OF ANY CONSTRUCTION PERMITS, THE APPLICANT SHALL SUBMIT A WATER POLLUTION CONTROL PLAN WPCP). THE WPCP SHALL BE PREPARED IN ACCORDANCE WITH THE GUIDELINES IN APPENDIX E OF THE CITY'S STORM WATER STANDARDS. 28. THIS PROJECT PROPOSES NO DEVELOPMENT IMPROVEMENTS OUTSIDE THE EXISTING BUILDING FOOTPRINT FOR THIS DISCRETIONARY REVIEW AND THEREFORE DOES NOT REQUIRE ANY PERMANENT STORM WATER BEST MANAGEMENT PRACTICES. 29. THIS PROJECT PROPOSES NO WORK WITHIN THE PUBLIC RIGHT-OF-WAY. 1. BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL BE IN ACCORDANCE WITH 2015 INTERNATIONAL BUILDING CODE AND ALL GOVERNING CODES. 2. ADDRESS SHALL BE PROVIDED FOR ALL PROPOSED AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.(2015 INTERNATIONAL BUILDING CODE 501.2) 3. DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.(2015 INTERNATIONAL BUILDING CODE 806.1) 4. PORTABLE FIRE EXTINGUISHERS: AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR.(2015 INTERNATIONAL BUILDING CODE 906.1.1 AND SECTION 906.3.1) STORM WATER QUALITY NOTES CONSTRUCTION BMPS: THIS PROJECT SHALL COMPLY WITH ALL REQUIREMENTS OF THE STATE PERMIT. NOTES 1-6 BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION BMP'S. 1. SUFFICIENT BMPS MUST BE INSTALLED TO PREVENT SILT, MUD OR OTHER CONSTRUCTION DEBRIS FROM BEING TRACKED INTO THE ADJACENT STREET(S) OR STORM WATER CONVEYANCE SYSTEMS DUE TO CONSTRUCTION VEHICLES OR ANY OTHER CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING ANY SUCH DEBRIS THAT MAY BE IN THE STREET AT THE END OF EACH WORK DAY OR AFTER A STORM EVENT THAT CAUSES A BREECH IN THE INSTALLED CONSTRUCTION BMPS. 2. ALL STOCK PILES OF UN-COMPACTED SOIL AND/OR BUILDING MATERIALS THAT ARE INTENDED TO BE LEFT UNPROTECTED FOR A PERIOD GREATER THAN SEVEN CALENDAR DAYS ARE TO BE PROVIDED WITH EROSION AND SEDIMENT CONTROLS, SUCH SOIL MUST BE PROTECTED EACH DAY WHEN THE PROBABILITY OF RAIN IS 40% OR GREATER. 3. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECTS WHICH PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPROVEMENTS THAT ARE TO BE POURED IN PLACE ON THE SITE. 4. ALL EROSION/SEDIMENT CONTROL DEVICES SHALL BE MAINTAINED IN WORKING ORDER AT ALL TIMES. 5. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTIVITY MUST BE PROTECTED AGAINST EROSION AND SEDIMENT TRANSPORT AT ALL TIMES. 6. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRONMENT. 3 NOT USED GROUND ACCESS WELL CADWELD MECHANICAL GRND. CONN. GROUND ROD GROUND BUS BAR NEW ANTENNA EXISTING ANTENNA PLYWOOD GRAVEL EARTH (E) MASONRY CONCRETE GROUT OR PLASTER (E) BRICK SET POINT FND. MONUMENT SPOT ELEVATION LIGHT POLE TELEPHONE BOX ELECTRIC BOX SECTION REFERENCE ELEVATION REFERENCE GRID REFERENCE DETAIL REFERENCE X REVISION MATCH LINE PROPERTY/LEASE LINE CENTERLINE WOOD BLOCKING STEEL WOOD CONT. SAND OVERHEAD SERVICE CONDUCTORS CHAIN LINK FENCING T/E X TELEPHONE CONDUITT ELECTRICAL CONDUIT COAXIAL CABLE (POWER) E A WORK POINT GROUND CONDUCTOR X X-X X X-X X X-X WOOD FENCE OVERHEAD POWER LINE BURIED POWER LINE BURIED WATER LINE BURIED SANITARY SEWER BURIED STORM DRAIN BURIED TELEPHONE LINE OVERHEAD TELEPHONE LINE FIBER POWER AND FIBER P/F F REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-1 SITE PLAN SITE PLAN 1 N EXISTING T-MOBILE EQUIPMENT & ANTENNA AREA, FOR ENLARGED SITE PLAN SEE: 1 A-2 EXISTING RESIDENTIAL BACK YARD 1 A-5 1 A-4 SW 330TH ST.CL DISCLAIMER THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. TAEC DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES, EASEMENTS, ROADS AND SETBACKS. LANDLORD SIGNATURE PROPERTY LINE: ± 75'- 6 "PROPERTY LINE: ± 53'-8"PROPERTY LINE: ± 46'-6"PROPERTY LINE: ± 121'-6"21ST AVE. SWCL2OTH PL. SWCLEXISTING RESIDENTIAL BUILDING EXISTING RESIDENTIAL BUILDING EXISTING CONC. SLAB EXISTING R.O.W. LANDSCAPE AREA EXISTING SIDEWALK (TYP.) EXISTING CONC. CURB & GUTTER EXISTING FENCE, TYP. SITE PARCEL NUMBER: N/A JURISDICTION: CITY OF FEDERAL WAY ZONING: R.O.W. SITE PARCEL NUMBER: 0104550010 JURISDICTION: CITY OF FEDERAL WAY ZONING: RS5.0 EXISTING DRIVEWAY REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF ENLARGED SITE PLAN N 1 A-2 ENLARGED SITE PLAN EXISTING T-MOBILE ANTENNA AREA, FOR ANTENNA PLAN SEE: 1 A-3 EXISTING T-MOBILE EQUIPMENT AREA, FOR EQUIPMENT PLAN SEE: 1 A-3.1( ) " " SECTOR @EA0°( ) " " SEC T O R @ E C 260° DISCLAIMER THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. TAEC DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES, EASEMENTS, ROADS AND SETBACKS. LANDLORD SIGNATURE EXISTING R.O.W. LANDSCAPE AREA EXISTING SIDEWALK (TYP.) EXISTING CONC. CURB & GUTTER EXISTING FENCE, TYP. EXISTING RESIDENTIAL BACK YARD EXISTING T-MOBILE COAX CABLE TRENCH (V.I.F.) REMOVE ALL EXISTING COAX CABLES ( ) " " S E C T O R @ E B 110°PROPERTY LINE: ± 46'-6" REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-3 ANTENNA PLANS N ANTENNA PLAN (EXISTING)21 N ANTENNA PLAN (FINAL) EXISTING 93.9 FT. HIGH TOWER EXISTING T-MOBILE (SBNHH-1D65C-SR) ANTENNA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED EXISTING T-MOBILE (ETM19V2S12UB) TMA (2 PER SECTOR, 3 SECTORS, 6 TOTAL) TO BE REMOVED LANDLORD SIGNATURE ( ) " " SECTOR @EA0°( ) " " SEC T O R @ E C 260° ( ) " " S E C T O R @ E B 110°( ) " " SECTOR @ND180°( ) " " SECTOR @NA0°( ) " " SEC T O R @ N C 260° ( ) " " S E C T O R @ N B 110° EXISTING 93.9 FT. HIGH TOWER COMMSCOPE TMATLABC21-21A 9.8" x 11.5" x 6.0"28.7TMA (6) (3) NEW T-MOBILE (SBWM-HD) WALL MOUNT (1 PER SECTOR D, 1 TOTAL) 7 A-6 EXISTING T-MOBILE (TMATLABC21-21A) TMA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED NEW T-MOBILE AHFIG (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 4 A-6 NEW T-MOBILE AHLOA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 3 A-6 NEW T-MOBILE (FFVV-65C-R3-V1) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 1 A-6 NEW T-MOBILE CROSSOVER PLATE (3 PER SECTOR, 3 SECTORS, 9 TOTAL) 11 A-6 NEW ANTENNA PIPES (10 TOTAL) NEW T-MOBILE (AEHC) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 2 A-6 (3) REMOVE EXISTING 1. ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS, MOUNTING HARDWARE, AND RF DESIGN. 2. REFER TO FINAL CONFIGURATION ANTENNA SCHEDULE ON SHEET RF-1. 3. EXISTING ANTENNAS BY OTHER CARRIERS ARE NOT SHOWN FOR CLARITY. 4. ALL NEW T-MOBILE ANTENNA EQUIPMENT TO BE PAINTED TO MATCH POLE. NOTE: TOWER: FINAL EQUIPMENT INVENTORY MODELSCOPE OF WORK QUANTITY MANUFACTURER DIMENSIONS (LxWxD) WEIGHT (LBS)TECHNOLOGY REMOVE EXISTING ADD NEW (4) (3)ADD NEW ADD NEW ADD NEW ADD NEW (9) ADD NEW COMMSCOPE SBNHH-1D65C HEX 96.6" x 11.9" x 7.1" 49.6ANTENNA COMMSCOPE FFVV-65C-R3-V1 95.9" x 25.2" x 9.3" 124.6ANTENNA AEHC 38.2" x 21.5" x 5.9"ANTENNA NOKIA 108.0 AHLOA 22.05" x 12.13" x 7.44" 83.78NOKIARRU NOKIARRU AHFIG 27.6" x 5.6" x 13.4" 79.4 PENDANT BREAKOUT 6.7" x 16.9" x 4.7"0.970 LB/FTCOMMSCOPEPENDANT SCX43-K 8.5" LONG 9.77VALMONT SITEPRO1CROSSOVER PLATE KIT REMOVE EXISTING (4) (4) (3) COMMSCOPE ETM19V2S12UB 10.0" x 8.6" x 2.3"11.2TMA NEW T-MOBILE HCS 2.0 PENDANT (1 PER SECTOR, 3 SECTORS, 3 TOTAL) 1 A-9 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-3.1 EQUIPMENT PLANS EXISTING T-MOBILE RACK TO BE REMOVED, 1 EXISTING SAR-A ROUTER TO BE REMOVED EXISTING NOKIA ULTRASITE CABINET TO BE REMOVED N EQUIPMENT PLAN (EXISTING)21 N EQUIPMENT PLAN (FINAL) EXISTING NOKIA ULTRASITE CABINET TO BE REMOVED EXISTING COAX CABLE STUB UPS EXISTING T-MOBILE DIPLEXERS (9 TOTAL) MOUNTED TO EXISTING UNISTRUT TO BE REMOVED EXISTING T-MOBILE FRLB (3 TOTAL) MOUNTED TO EXISTING UNISTRUT FRAME TO BE REMOVED EXISTING T-MOBILE TELCO BOARD EXISTING T-MOBILE UTILITY PANEL EXISTING T-MOBILE ELEC. PANEL EXISTING T-MOBILE EQUIPMENT SHELTER EXISTING T-MOBILE TELCO BOARD EXISTING T-MOBILE UTILITY PANEL EXISTING T-MOBILE ELEC. PANEL EXISTING T-MOBILE EQUIPMENT SHELTER 15'-0"10'-0" NEW T-MOBILE HCS 2.0 JUNCTION BOXES ON EXISTING UNISTRUTS ON WALL (3 TOTAL) 1 A-9 15'-0"10'-0" EXISTING T-MOBILE DOOR & FRAME TO BE REMOVE & REPLACED EXISTING COAX CABLE STUB UPS NEW T-MOBILE HPL3 600A SSC CABINET WITH 1 CSR IXRe ROUTER, 2 VOLTAGE BOOSTER, 2 AMIA, 2 ASIB, 2 ASIK, 3 ABIA, 5 ABIL, AND 3 ABIC INSIDE CABINET 5 A-6 NEW T-MOBILE LB3 BATTERY CABINET 6 A-6 1'-6" MIN. 1 A-7 2 A-7 3 A-7 4 A-7 5 A-7 6 A-7 7 A-7 LANDLORD SIGNATURE GROUND: FINAL EQUIPMENT INVENTORY EQUIPMENT MODELSCOPE OF WORK QUANTITY MANUFACTURER DIMENSIONS (LxWxD) WEIGHT (LBS)TECHNOLOGY CABINET TYPE (LOCATION OF EQUIPMENT) CABINET QUANTITY REMOVE EXISTING (2)-- REMOVE EXISTING (2)ULTRASITE CABINET (3) (1) (1)-- --ROUTER NOKIA 7705 SAR-A RACK RACK PURCELL --INDOOR RACK 1 1 REMOVE EXISTING REMOVE EXISTING (1)--BASEBAND NOKIA FSMF ULTRASITE CABINET 1 REMOVE EXISTING REMOVE EXISTING ON H-FRAME - CABINET NOKIA 6'-7/16" x 2.5' x 2.5'TBDULTRASITE 5.2" x 11.76" x 16.6" 41.9BASEBAND NOKIA FSME 15.75" x 15.75" x 5.9" 59.52RRUNOKIAFRLB (3)REMOVE EXISTING (6)REMOVE EXISTING WALL - WALL - 8.9" x 4.9" x 4.5" 10.1 DIPLEXER COMMSCOPE CDX723AT-DS ECC1920-VPUB 7.6" x 7.3" x 2.6"7.9COMMSCOPEDIPLEXER (3)REMOVE EXISTING (2)REMOVE EXISTING REMOVE EXISTING (2) ULTRASITE CABINET 1 ULTRASITE CABINET 1 ULTRASITE CABINET 1 RRU NOKIA FRIA 5.2" x 11.76" x 15.6" 55.1 RRU NOKIA 5.2" x 17.6" x 15.6" 55.1FRIE 5.2"x17.6"x16.6" 55.1RRUNOKIA FXFC GROUND: FINAL EQUIPMENT INVENTORY EQUIPMENT MODELSCOPE OF WORK QUANTITY MANUFACTURER DIMENSIONS (LxWxD) WEIGHT (LBS)TECHNOLOGY CABINET TYPE (LOCATION OF EQUIPMENT) CABINET QUANTITY (1)ADD NEW (1)ADD NEW (2)ADD NEW (2)ADD NEW (2)ADD NEW EXISTING TO REMAIN (1)1 ADD NEW (1) HPL3 600A SSC5.2" x 11.76" x 16.6" 41.9BASEBAND NOKIA FSMF CABINET PURCELL 30.0" x 48.0" x 72.0" 430HPL3 600A LARGE SSC CABINET PURCELL 60.4" x 30" x 33.8" 350HPL3 LB3 BATTERY ROUTER NOKIA 8.57250 IXR-e VOLTAGE BOOSTER RAYCAP 2.1POWERPLUS 103-1-1U BASEBAND NOKIA 11.2AMIA BASEBAND NOKIA 1.8" x 8.6" x 14.8" 6.61ASIB BASEBAND NOKIA --ASIK BASEBAND NOKIA --ABIL BASEBAND NOKIA 14.2" x 8.6" x 1.1" 4.41ABIA BASEBAND NOKIA 0.98" x 8.62" x 14.33" 5.84ABIC JUNCTION BOX COMMSCOPE 15.21FE-16148-OVP-B12 (5)ADD NEW (3)ADD NEW (3)ADD NEW ADD NEW ADD NEW 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC 1HPL3 600A SSC -WALL (2) (3) NEW T-MOBILE CAC PANEL ON EXISTING WALL 8 A-7 NEW T-MOBILE CUBE ON EXISTING WALL 9 A-7 10 A-7 26" x 22" x 20"TELCO CABINET CHARLES RL1000 90ADD NEW -WALL(1) 20" x 10" x 39"75PPC/DISCONNECT EMERSON CAC MODELADD NEW -WALL(1) REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-4 ELEVATIONS 21SOUTH ELEVATION (EXISTING) SOUTH ELEVATION (FINAL) DISCLAIMER: 1. EXISTING TOWER HEIGHT AND ANTENNA DEPICTED ON THE ELEVATION IS BASED ON 1-A DATED: 04/21/2015 PROVIDED BY AMBIT CONSULTING. 2. CAPACITY OF THE TOWER TO SUPPORT PROPOSED LOADS IS TO BE DETERMINED BY OTHERS. 3. ALL NEW T-MOBILE ANTENNA EQUIPMENT TO BE PAINTED TO MATCH EXISTING POLE. LANDLORD SIGNATURE RAD CENTER OF EXISTING T-MOBILE ANTENNA ELEV. ±89.8' TOP OF EXISTING T-MOBILE ANTENNA & EXISTING UTILITY POLE ELEV. ±93.9' FINISH GRADE ELEV. 0'-0" REF TOP OF EXISTING OVER HEAD UTILITY LINES ELEV. ±80.0' EXISTING T-MOBILE EQUIPMENT AREA, FOR EQUIPMENT PLAN SEE: 1 A-3.1 EXISTING 93.9 FT. HIGH TOWER EXISTING T-MOBILE (SBNHH-1D65C-SR) ANTENNA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED EXISTING T-MOBILE (ETM19V2S12UB) TMA (2 PER SECTOR, 3 SECTORS, 6 TOTAL) TO BE REMOVED EXISTING OVERHEAD UTILITY LINES, TYP. RAD CENTER OF NEW T-MOBILE ANTENNA ELEV. ±89.8' TOP OF NEW T-MOBILE ANTENNA & EXISTING UTILITY POLE ELEV. ±93.9' FINISH GRADE ELEV. 0'-0" REF TOP OF EXISTING OVER HEAD UTILITY LINES ELEV. ±80.0' NEW T-MOBILE EQUIPMENT AREA, FOR EQUIPMENT PLAN SEE: 2 A-3.1 EXISTING 93.9 FT. HIGH TOWER EXISTING OVERHEAD UTILITY LINES, TYP. EXISTING T-MOBILE (TMATLABC21-21A) TMA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED RAD CENTER OF NEW T-MOBILE ANTENNA ELEV. ±92.3' NEW T-MOBILE (SBWM-HD) WALL MOUNT (1 PER SECTOR D, 1 TOTAL) 7 A-6 NEW T-MOBILE AHFIG (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 4 A-6 NEW T-MOBILE AHLOA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 3 A-6 NEW T-MOBILE (FFVV-65C-R3-V1) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 1 A-6 NEW T-MOBILE CROSSOVER PLATE (3 PER SECTOR, 3 SECTORS, 9 TOTAL) 11 A-6 NEW T-MOBILE (AEHC) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 2 A-6 NEW T-MOBILE HCS 2.0 PENDANT (1 PER SECTOR, 3 SECTORS, 3 TOTAL) 1 A-9 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-5 ELEVATIONS 21WEST ELEVATION (EXISTING) WEST ELEVATION (FINAL) LANDLORD SIGNATURE RAD CENTER OF EXISTING T-MOBILE ANTENNA ELEV. ±89.8' TOP OF EXISTING T-MOBILE ANTENNA & EXISTING UTILITY POLE ELEV. ±93.9' FINISH GRADE ELEV. 0'-0" REF TOP OF EXISTING OVER HEAD UTILITY LINES ELEV. ±80.0' EXISTING T-MOBILE EQUIPMENT AREA, FOR EQUIPMENT PLAN SEE: 1 A-3.1 EXISTING 93.9 FT. HIGH TOWER EXISTING T-MOBILE (SBNHH-1D65C-SR) ANTENNA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED EXISTING T-MOBILE (ETM19V2S12UB) TMA (2 PER SECTOR, 3 SECTORS, 6 TOTAL) TO BE REMOVED EXISTING OVERHEAD UTILITY LINES, TYP. NEW T-MOBILE EQUIPMENT AREA, FOR EQUIPMENT PLAN SEE: 2 A-3.1 FINISH GRADE ELEV. 0'-0" REF TOP OF EXISTING OVER HEAD UTILITY LINES ELEV. ±80.0' EXISTING 93.9 FT. HIGH TOWER EXISTING OVERHEAD UTILITY LINES, TYP. EXISTING T-MOBILE (TMATLABC21-21A) TMA (1 PER SECTOR, 3 SECTORS, 3 TOTAL) TO BE REMOVED DISCLAIMER: 1. EXISTING TOWER HEIGHT AND ANTENNA DEPICTED ON THE ELEVATION IS BASED ON 1-A DATED: 04/21/2015 PROVIDED BY AMBIT CONSULTING. 2. CAPACITY OF THE TOWER TO SUPPORT PROPOSED LOADS IS TO BE DETERMINED BY OTHERS. 3. ALL NEW T-MOBILE ANTENNA EQUIPMENT TO BE PAINTED TO MATCH EXISTING POLE. RAD CENTER OF NEW T-MOBILE ANTENNA ELEV. ±89.8' TOP OF NEW T-MOBILE ANTENNA & EXISTING UTILITY POLE ELEV. ±93.9' RAD CENTER OF NEW T-MOBILE ANTENNA ELEV. ±92.3' NEW T-MOBILE (SBWM-HD) WALL MOUNT (1 PER SECTOR D, 1 TOTAL) 7 A-6 NEW T-MOBILE AHFIG (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 4 A-6 NEW T-MOBILE AHLOA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 3 A-6 NEW T-MOBILE (FFVV-65C-R3-V1) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 1 A-6 NEW T-MOBILE CROSSOVER PLATE (3 PER SECTOR, 3 SECTORS, 9 TOTAL) 11 A-6 NEW T-MOBILE (AEHC) ANTENNA (1 PER SECTOR, 4 SECTORS, 4 TOTAL) 2 A-6 NEW T-MOBILE HCS 2.0 PENDANT (1 PER SECTOR, 3 SECTORS, 3 TOTAL) 1 A-9 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF DETAILS A-6312 11 7 6 5 2 4 1AHFIG NOKIA: AIRSCALE 4T4R DUAL MID-BAND RADIO FEATURES: 4T4R DUAL MID-BAND RADIO LTE + 5G DIMENSIONS: 27.6" x 13.4" x 5.6" (HxWxD) WEIGHT: 79.4 LBS PERSPECTIVE VIEW:FRONT VIEWSIDE VIEWPLAN VIEW 27.6"5.6" 13.4" NOKIA: (AIRSCALE DUAL RRH 4T4R B12/71 240W AHLOA RF MODULE TYPE: RRH, 1 UNIT PER SECTOR DIMENSIONS, HxWxD: 22.05" x 12.13" x 7.44" (WITHOUT BRACKETS) WEIGHT: 83.78 lbs (MOUNTED WEIGHT) AHLOA PERSPECTIVE VIEW:FRONT VIEWSIDE VIEWPLAN VIEW 22.05"7.44" 12.13" NOKIA: MASSIVE MIMO ADAPTIVE ANTENNA (AEHC) OUTPUT POWER: 5 W / TRX (320 W total, 2 W/MHz up to 160 MHz) FREQUENCY RANGE: 2496 MHz - 2690 MHz 3GPP B41 DIMENSIONS: 38.2"x 5.9"x21.5" (WITH FRONT COVERS) WEIGHT: 108.0 LBS ANTENNA SPECIFICATIONS 3 STANDOFF AND PIPE DETAIL 4 5 6 2-3/8" O.D. PIPE (ORDERED SEPARATELY) 3 4 2 6 3-1/2" ANTENNA PIPE (ORDERED SEPARATELY) 6 8 G12NUT 1/2'' HDG HEAVY 2H HEX NUT 0.07 0.57 5 2 X-UB1358 1/2" X 3-5/8" X 5-1/2" X 3" U-BOLT (HDG.) 0.66 1.31 4 8 G12LW 1/2" HDG LOCKWASHER 0.01 0.11 3 8 G12FW 1/2" HDG USS FLATWASHER 0.03 0.27 2 2 X-UB1212 1/2" X 2-1/2" X 4-1/2" X 2" U-BOLT (HDG.)0.63 1.25 1 1 SCX4 CROSSOVER PLATE 8 1/2 in 6.02 6.02 ITEM QTY PART NO. PART DESCRIPTION LENGTH UNIT WT. NET WT. PARTS LIST 9.77TOTAL WT. # 1 COMMSCOPE: FFVV-65C-R3-V1 RADOME MATERIAL: FIBERGLASS, UV RESISTANT RADOME COLOR: LIGHT GRAY DIMENSIONS, HxWxD: 95.9" x 25.2" x 9.3" NET WEIGHT: 124.6 lb (56.5 kg) RF CONNECTOR QUANTITY: (8) 4.3 - 10 FEMALE (4) HIGH BAND, (4) LOW BAND RET INTERFACE 8-PIN DIN FEMALE | 8-PIN DIN MALE ANTENNA SPECIFICATIONS 95.9"9.3" 25.2" WALL MOUNT 4 5 6 VALMONT SITE PRO 1: SBWM-HD NOTE: 3-1/2" TO 4-1/2" O.D. ANTENNA PIPE ORDER SEPARATELY 11 4 X-UB1458 1/2" X 4-5/8" X 7" X 3" GALV U-BOLT 0.97 3.89 11 4 X-UB1358 1/2" X 3-5/8" X 5-1/2" X 3" GALV U-BOLT 0.77 3.09 10 8 G12NUT 1/2'' HDG HEAVY 2H HEX NUT 0.07 0.57 9 G12LW 1/2" HDG LOCKWASHER 0.01 0.11 8 G12FW 1/2" HDG USS FLATWASHER 0.03 0.27 7 G58NUT 5/8'' HDG HEAVY 2H HEX NUT 0.13 1.04 6 G58LW 5/8" HDG LOCKWASHER 0.03 0.21 5 G58FW 5/8" HDG USS FLATWASHER 0.07 0.56 4 G5802 5/8" x 2" HDG HEX BOLT GR5 0.27 2.16 3 4 X-SLD-A SLIDER BRACKET ANGLE 10 in 3.28 13.12 2 X-SLD3 SLIDER BRACKET WALL ANGLE 14 1/2 in 6.10 12.20 1 2 X-SLD-BP SLIDER BRACKET BENT PLATE 8.13 16.26 ITEM QTY PART NO. PART DESCRIPTION LENGTH UNIT WT. NET WT. PARTS LIST 53.48TOTAL WT. # SIDE VIEWFRONT VIEW PLAN VIEWISOMETRIC VIEW 14-1/2" REF. 11-5/8" REF. DETAIL A A - 7 1 2 3118910 10-1/2"30" TYP.12" REF. 3-1/2" TO 4-1/2" O.D. ANTENNA PIPE ORDER SEPARATELY 13/16" Ø X 1" THRU SLOT REF. 2 8 8 8 8 8 8 EQUIPMENT SHELTER CONCRETE SLAB 1/2"Ø HILTI KB-TZ W/ 2" EMBED. 2" SQUARE GALVANIZED STEEL SHIM PLATE WHERE REQUIRED TO LEVEL CABINET ANCHOR DETAIL CABINET, PER PLAN NOTE: ANCHORAGE OCCURS AT EACH CORNER OF THE CABINET 1. 2. 3. 4. 5. 6. 1. KNOCKOUT FOR ETHERNET FOR ALARMS 2. KNOCKOUTS FOR BATTERY WIRES 3. 4X BATTERY SHELVES, UP TO 200AH 4. BATTERY BRACKETS 5. BATTERY VIBRATION MOUNTS 6. SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) FRONT VIEWPLAN VIEW PURCELL HPL3 LARGE BATTERY CABINET OUTDOOR CABINET DIMENSIONS, HxWxD: (60.4"x30"x33.8") WEIGHT: 350lbs (CABINET ONLY) OPERATING TEMP: -40°C TO +50°C COOLING: DIRECT AIR COOLING (2) FANS ***REFERENCE MANUFACTURER'S SPECIFICATIONS FOR DETAILED EQUIPMENT INFORMATION CABINET SPECIFICATIONS SIDE VIEW60.4"33.8"30"60.4"31.6"30"33.8"31.6" ISOMETRIC VIEW OPEN FRONT VIEW FRONT VIEWPLAN VIEW PURCELL: HPL3 600A LARGE SSC OUTDOOR CABINET DIMENSIONS, HxWxD: (72"x30"x48") WEIGHT: 430lbs (CABINET ONLY) OPERATING TEMP: -40°C TO +50°C COOLING: DIRECT AIR COOLING ***REFERENCE MANUFACTURER'S SPECIFICATIONS FOR DETAILED EQUIPMENT INFORMATION CABINET SPECIFICATIONS SIDE VIEW72"48"30"72"32"30"48"ISOMETRIC VIEW 2. 3. 4. 5.6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 1. FIBER ROUTE OPTION: 4 KNOCKOUTS FOR COVP W/ WATER-TIGHT LB OR GROMMET. 2. 6 KNOCKOUTS FROM INTERNAL AIRSCALE EQUIPMENT. 3. KNOCKOUT FOR ETHERNET FOR ALARM 4. KNOCKOUTS FOR BATTERY WIRES 5. FIBER KNOCKOUT 6. ALL DC POWER CABLES ROUTED ON LEFT SIDE 7. FIBER CABLES YELLOW 8. 19" RACK ADAPTER 9. ALL FIBER CABLES ROUTED ON RIGHT SIDE 10. AIRSCALE BASEBAND 11. FIBER MUX/DEMUX 12. RECTIFIERS (10 POSITIONS) 13. ALPHA POWER (48 BREAKER SLOTS) 14. CSR ROUTER 15. AIRSCALE BASEBAND 16. LEGACY BASEBAND 17. SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) 1. INTERNAL ROUTING & FRONT VIEW REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF DETAILS A-739 8 7 6 5 2 4 1 NOKIA: AIRSCALE SUBRACK INDOOR (AMIA) DIMENSIONS: 5.1" x 15.7" x 17.6" WEIGHT: 11.2 lbs. (AMIA ENCLOSURE) INGRESS PROTECTION: IP20 OPERATING TEMPERATURE: -5°C UP TO +55°C OR 60°C (INDOOR) INSTALLATION TEMPERATURE: MAIN PROPERTIES: IT SUPPORTS UP TO 2 AIRSCALE COMMON PLUG-IN UNITS. IT SUPPORTS UP TO 6 AIRSCALE CAPACITY PLUG-IN UNITS. I CAN BE INSTALLED INSIDE A 19" WIDE RACK OR CABINET. IT INCLUDES A SUBRACK FRAME, A BACKPLANE FOR HIGH BANDWIDTH INTERCONNECT BETWEEN AIRSCALE COMMON AND AIRSCALE CAPACITY PLUG-IN UNITS, HAS FANS WITH CHANGEABLE AIRFLOW DIRECTION, AND HAS BLIND-UNITS TO PREVENT COOLING AIRFLOW LEAKAGE. AMIA FRONT AND REAR VIEWS NOKIA: AIRSCALE BASEBAND 5G ONLY CARDS (ABIL) FEATURES: INITIAL AIRSCALE BASEBAND 5G ONLY CARDS ABIL PERSPECTIVE VIEW NOKIA: AIRSCALE BASEBAND 5G ONLY CARDS (ASIK) FEATURES: INITIAL AIRSCALE BASEBAND 5G ONLY CARDS ASIK PERSPECTIVE VIEW NOKIA: AIRSCALE CAPACITY UNIT (ABIA) DIMENSIONS: 14.2"X8.6"X1.1" WEIGHT: 4.41 lbs. PRODUCT CODE: 473096A FUNCTIONS: INDOOR CAPACITY EXTENSION PLUG IN UNIT. HAS 6 OPTICAL RF INTERFACES UP TO 6 Gbps OBSAI OR 9.8 Gbps CPRI. IQ-COMPRESSION IS SUPPORTED WITH 3 CPRI LINKS ABIA PERSPECTIVE VIEW NOKIA: AIRSCALE CAPACITY BASEBAND MODULE (ASIB) DIMENSIONS: 1.8"x8.6"x14.8" WEIGHT: 6.61 lbs. PRODUCT CODE: LTE3178 FUNCTIONS: INDOOR COMMON PLUG IN UNIT. INCLUDES TRANSPORT AND CENTRALIZED CONTROL FUNCTIONS FOR SUPPORTED RADIO ACCESS TECHNOLOGIES. ASIB PERSPECTIVE VIEW NOKIA: AIRSCALE CAPACITY BASEBAND MODULE (ABIC) DIMENSIONS: 0.98"x8.62"x14.33" WEIGHT: 5.84 lbs. PRODUCT CODE:474723A FUNCTIONS: ENHANCED INDOOR CAPACITY EXTENSION PLUG IN UNIT. ABIC PERSPECTIVE VIEW 10 NOKIA: 7250 IXR-e INTERCONNECT ROUTER 7250 IXR-e 24SFP+8SFP28 2QSFP28 FRONT VIEW 7250 IXR-e 14SFP+4T FRONT VIEW PARAMETER DESCRIPTION DIMENSIONS (HXWXD): 1.75"X17.25"X10.0" CHASIS WEIGHT (UNPOPULATED): 7250 IXR-E 24SFP+ 8SFP28 2QSFP28: 8.5 LBS 7250 IXR-E 14SFP+ 4T: 8.0 LBS PSU SLOT: 2 MOUNTING: MOUNT IN A RECOMMENDED 19-INCH EQUIPMENT RACK. THE CHASSIS HAS FACTORY-INSTALLED MOUNTING FLANGES FOR FLUSH-MOUNTING, FACING FORWARDS, IN A 19-INCH RACK. VOLTAGE BOOSTER RAYCAP: POWERPLUS 100-3-1U DIMENSIONS: 17.6" x 13.5" x 1.7" WEIGHT: 2.1 LBS CAC MODEL EMERSON: CAC MODEL MANUFACTURER: EMERSON MODEL: CAC MODEL DIMENSIONS: 39"H x 20"W x 10"D WEIGHT: 70 LBS (AC CABINET) 20 LBS (TELCO CABINET) MOUNTING: WALL OR PAD MOUNT ENCLOSURE TYPE: (AC CABINET): ONE AC POWER TVSS CABINET (NEMA 3R TYPE ENCLOSURE, (TELCO CABINET): SINGLE CABINET (NEMA 3R TYPE ENCLOSURE) WEATHER PROTECTION: RAIN/DRIP HOOD, RAIN TESTED PER UL 891 (AC CABINET) UL 50 (TELCO CABINET) OPERATING VOLTAGE: 120/240 VAC, SINGLE PHASE, 3 WIRE AND GROUND SERVICE: 100 AMP OR 200 AMP UTILITY/STANDBY DISCONNECT: SLIDE BAR MECHANICAL INTERLOCK AIC RATING: 10kAIC, 22kAIC, 65kAIC LOAD CENTER: 200 AMP, 24 POSITION 1-30 AMP DOUBLE POLE (AC TVSS) 1-15 AMP SINGLE POLE (GFI RECEPTACLES) BONDING JUMPER: OPTIONAL N-G JUMPER STANDBY POWER RECEPTACLES: APPLETON AR20044RS STANDARD (100A OR 200A), 10kAIC TVSS WITH INDICATOR LIGHTS: METAL OXIDE VARISTORS (MOV) (160kA/PHASE) REMOTE ALARM CONTACTS GROUNDING: TELCO GROUND BAR (TELCO CABINET) SECURITY (PADLOCKABLE): 3-POINT DOOR CLOSURE WITH 1/4 TURN HANDLE, SS HINGE (AC CABINET) 1/4 TURN HANDLE, SS HINGE (TELCO CABINET) SAFETY COMPLIANCE: UL 891, DEAD FRONT SWITCHBOARDS (AC CABINET) UL 50, CABINETS AND CUTOUT BOXES FRONT ELEVATION PLAN VIEW 20"10"39"BACKHAUL CABINET CHARLES UNIVERSAL BROADBAND ENCLOSURES (CUBE) RL1000 SERIES BACKHAUL CABINETS MANUFACTURER: CHARLES MODEL: CUBE RL1003 DIMENSIONS: 22"H x 22"W x 20"D WEIGHT: 90 LBS (EMPTY) RU: 14 MOUNTING RAILS: 19" FIXED RAIL LOAD CENTER: NONE 32.3"20.1"26.3"19.5"23.0"32.3"5X Ø1.75/Ø2.50 41.8"19.6"22.8' 27.6" LEFT ELEVATION FRONT ELEVATION RIGHT ELEVATION WITH DOOR OPEN BOTTOM VIEW PLAN VIEW WITH DOOR OPEN REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-8 ANTENNA MOUNTING SPECIFICATIONS 1ANTENNA MOUNTING SPECIFICATIONS LANDLORD SIGNATURE REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF A-91 HELIAX FIBER FEED PENDANT CONNECT HELIAX FIBER FEED PENDANT CONNECT REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF ELECTRICAL NOTES E-1ELECTRICAL GENERAL NOTES 4 3 1 GENERAL ABBREVIATIONS GENERAL LEGEND LIGHTING FIXTURE, 1/175W. METAL HALIDE, HUBBELL CAT #MIC-0175H-336 5/8" X 10'-0" ,CU. GND ROD 30" MIN. BELOW GRADE.OVERHEAD TELEPHONE LINE OVERHEAD TELEPHONE/OVERHEAD POWER CADWELD CONNECTION CHEMICAL GROUND ROD (XIT GROUND ROD) 5/8" X 10'-0" ,CU. GND ROD IN TEST WELL 30" MIN. BELOW GRADE.OVERHEAD POWER LINE POWER RUN TELCO RUN POWER/TELCO RUN LIGHTING FIXTURE, HIGH PRESSURE SODIUM, 1/70W, WALL MOUNTING TYPE, HUBBELL LIGHTING CATALOG #NRG-307 OR 1/50W, HUBBELL LIGHTING CATALOG #NRG-121 LIGHTING FIXTURE, INCANDESCENT, 1/100W, WALL MOUNTING TYPE, HUBBELL LIGHTING CATALOG #BRH-100-06-1 LIGHTING FIXTURE, HALOGEN, QUARTZ, 1/300W, HUBBELL LIGHTING CATALOG #QL-505 EMERGENCY LIGHTING, 2/50W, HUBBELL LIGHTING CATALOG #HE6-50-2-R91 EXIT SIGN, THERMOPLASTIC LED, SINGLE FACE, UNIVERSAL MOUNTING, W/BATTERY PACK, HUBBELL LIGHTING CATALOG #PRB COMBINATION, EXIT SIGN & EMERGENCY LIGHTING, HUBBELL LIGHTING CATALOG #PRC MANUAL TRANSFER SWITCH, 2P-240V-200A, NO FUSE, NEMA 3R ENCLOSURE LIGHTING FIXTURE, FLUORESCENT, 10.94" x 4'-0", 2/40W, SURFACE MOUNTING TYPE, HUBBELL LIGHTING CATALOG #WSW232T LIGHTING FIXTURE, FLUORESCENT, 10.94" x 8'-0", 2/95W, SURFACE MOUNTING TYPE, HUBBELL LIGHTING CATALOG #TWSM232T FUSE, SIZE AND TYPE AS INDICATED. SAFETY SWITCH, 2P-240V-60A W/60A FUSES, NEMA 3R ENCLOSURE, SQ D CATALOG NO. H222NRB SAFETY SECONDARY SURFACE SWITCH SOFT DRAWN BARE COPPER SOLID NEUTRAL TYPICAL WITH VOLT VOLT ALTERNATING CURRENT WATT OR WIRE UNDERWRITER'S LABORATORY INC. UNDERGROUND TELEPHONE TRANSFER WITHOUT CROSS-LINK POLYETHYLENE TRANSFORMER MANUFACTURER MOUNTED MOUNTING NEUTRAL MINIMUM MAIN LUGS ONLY W V OVERHEAD PHASE PANELBOARD POLE PERSONAL COMMUNICATION SYSTEM NATIONAL ELECTRICAL MANUFACTURERS ASSOC. NEW MFR MLO MTG N MTD MIN NEMA OH PCS PH P (N) PNLBD RECEPTACLE POWER PRIMARY RIGID GALVANIZED STEEL POWER PROTECTION CABINET PRIMARY RADIO CABINET PPC PRC RCPT PWR PRI RGS W/O XFER XLPE XFMR TEL VAC W/ TYP U.L. U/G SDBC SURF SEC SW S.N. SAF ELEC ENCL FAC F/A EXIST EMT FT G GEN FU GPS GR GND GFCI FLUOR A AIC ACCA AT BD BR AWG C CAB BTS BTCW BRKR APPROX AMPERE BRANCH BARE TINNED COPPER WIRE APPROXIMATELY AMERICAN WIRE GAGE AMPERE TRIP AMPERE INTERRUPTING CAPACITY BREAKER ANTENNA CABLE COVER ASSEMBLY CONDUIT CABINET BASE TRANSMISSION SYSTEM BOARD HDBC HPS LPS MAX LG MECH CB CKT DEM (E) CONT CIRCUIT DEMAND EXISTING CIRCUIT BREAKER CONTINUOUS HARD DRAWN COPPER WIRE LOW PRESSURE SODIUM MECHANICAL MAXIMUM HIGH PRESSURE SODIUM LENGTH FLUORESCENT FUSE GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND FOOT/FEET GLOBAL POSITIONING SYSTEM GROWTH GROUNDING ELECTRICAL METALLIC TUBING ELECTRICAL ENCLOSURE FIRE ALARM FACTOR EXISTING UNLESS NOTED OTHERWISEU.N.O. EGR EMERGENCY GEN. RECEPTACLE MANUAL TRANSFER SWITCHMTS GROUNDING CONDUCTOR GROUNDING CONDUCTOR CONDUIT UNDERGROUND BATT BATTERY CIRCUIT BREAKER MECHANICAL CONNECTION HALO GROUND CONNECTION STEPDOWN TRANSFORMER UTILITY METER BASE TRANSFORMER RECEPTACLE, 2P-3W-125V-15A, DUPLEX, GROUND TYPE, HUBBEL CATALOG #5362 TOGGLE SWITCH, 1P-120V-15A, "WP" TOGGLE SWITCH, 1P-125V-15A, HUBBELL CATALOG #HBL 1201CN POLE (N) POLE MOUNTED XFMER (E) POLE MOUNTED XFMR (E) PAD MOUNTED XFMER (N) PAD MOUNTED XFMER IONIZATION SMOKE DETECTOR W/ALARM HORN & AUXILIARY CONTACT, 120 VAC, GENTEX PART NO. 7100F 1. GENERAL REQUIREMENTS A. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE NATIONAL ELECTRIC CODE AND ALL STATE AND LOCAL CODES. NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMIT WORK NOT CONFORMING TO THE MOST STRINGENT OF THESE CODES. SHOULD CHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO MAKE THE WORK COMPLY WITH THESE REQUIREMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING AND CEASE WORK ON PARTS OF THE CONTRACT WHICH ARE AFFECTED. B. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND CONSTRUCTION TO VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF ANY DISCREPANCIES THE CONTRACTOR ASSUMES ALL LIABILITY FOR FAILURE TO COMPLY WITH THIS PROVISION. C. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, SCHEDULES, AND SPECIFICATIONS AND IS SUBJECT TO THE TERMS AND CONDITIONS OF THE CONTRACT. THE WORK SHALL CONSIST OF FURNISHING ALL LABOR, EQUIPMENT, MATERIALS AND SUPPLIES NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM. THE WORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL WORK NOT MENTIONED OR SHOWN WHICH ARE NECESSARY FOR SUCCESSFUL OPERATION OF ALL SYSTEMS. D. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND OPERATIONAL SYSTEM, WHICH INCLUDES THE COST FOR MATERIAL AND LABOR. E. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS THE OPERATION. DEFECTIVE OR DAMAGED MATERIALS SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL ACCEPTANCE IN A MANNER ACCEPTABLE TO OWNER AND ARCHITECT/ENGINEER. F. COMPLETE THE ENTIRE INSTALLATION AS SOON AS THE PROGRESS OF THE WORK WILL PERMIT. ARRANGE ANY OUTAGE OF SERVICE WITH THE OWNER AND BUILDING MANAGER IN ADVANCE. MINIMIZE DOWNTIME ON THE BUILDING ELECTRICAL SYSTEM. G. THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT SHALL BE DELIVERED IN PROPER WORKING ORDER. REPLACE, WITHOUT ADDITIONAL COST TO THE OWNER, ANY DEFECTIVE MATERIAL AND EQUIPMENT WITHIN ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. H. ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER FOR CLARIFICATION OR CORRECTION BEFORE CONSTRUCTION. I. "PROVIDE": INDICATES THAT ALL ITEMS ARE TO BE FURNISHED, INSTALLED AND CONNECTED IN PLACE. J. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS AND PAY ALL REQUIRED FEES. 2. EQUIPMENT LOCATION A. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATIONS OR ARRANGEMENTS OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE CONDITIONS ENCOUNTERED. B. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARE NECESSARY, DUE TO FIELD CONDITIONS IN THE BUILDING CONSTRUCTION OR REARRANGEMENT OF FURNISHINGS OR EQUIPMENT, SUCH CHANGES SHALL BE MADE WITHOUT COST, PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC., AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED AND NO EXTRA MATERIALS ARE REQUIRED. C. LIGHTING FIXTURES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS ONLY. COORDINATE THE FIXTURE LOCATION WITH MECHANICAL EQUIPMENT TO AVOID INTERFERENCE. COORDINATE THE WORK OF THIS SECTION WITH THAT OF ALL OTHER TRADES. WHERE CONFLICTS OCCUR, CONSULT WITH THE RESPECTIVE CONTRACTOR AND COME TO AGREEMENT AS TO CHANGES NECESSARY. OBTAIN WRITTEN ACCEPTANCE FROM ARCHITECT/ENGINEER FOR THE NEW CHANGES BEFORE PROCEEDING. 3. SHOP DRAWINGS A. N/A UNLESS NOTED OTHERWISE. 4. SUBSTITUTIONS A. NO SUBSTITUTIONS ARE ALLOWED. 5. TESTS A. BEFORE FINAL ACCEPTANCE OF WORK, THE CONTRACTOR SHALL INSURE THAT ALL EQUIPMENT, SYSTEMS, FIXTURES, ETC., ARE WORKING SATISFACTORILY AND TO THE INTENT OF THE DRAWINGS. 6. PERMITS A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING OUT AND PAYING FOR ALL THE REQUIRED PERMITS, INSPECTION AND EXAMINATION WITHOUT ADDITIONAL EXPENSE TO THE OWNER. 7. GROUNDING A. THE CONTRACTOR SHALL PROVIDE A COMPLETE, AND APPROVED GROUNDING SYSTEM INCLUDING ELECTRODES. ELECTRODE CONDUCTOR, BONDING CONDUCTORS, AND EQUIPMENT CONDUCTORS AS REQUIRED BY ARTICLE 250 OF NATIONAL ELECTRICAL CODE. B. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE METALLICALLY JOINED TOGETHER TO PROVIDE AN EFFECTIVE ELECTRICAL CONTINUITY. C. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A NONMETALLIC CONDUIT SHALL INCLUDE A CODE SIZED GROUNDING CONDUCTOR HAVING GREEN INSULATION. THE GROUND CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO MAINTAIN ELECTRICAL CONTINUITY. D. REFER TO GROUND BUS DETAILS. PROVIDE NEW SYSTEM, COMPLETE WITH CONDUCTORS, GROUND ROD(S) AND DESCRIBED TERMINATIONS. E. ALL GROUNDING CONDUCTORS SHALL BE SOLID LINED COPPER AND ANNEALED #2 UNLESS NOTED OTHERWISE. F. ALL NON-DIRECT BURIED TELEPHONE EQUIPMENT CONDUCTORS SHALL BE #2 STRANDED, GROUND THHN (GREEN) INSULATION. G. ALL GROUND CONNECTIONS SHALL BE MADE WITH "HYGROUND" COMPRESSION SYSTEM BURNDY CONNECTORS EXCEPT WHERE NOTED OTHERWISE. H. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED. I. GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS. IF THE RESISTANCE VALUE IS EXCEEDED, NOTIFY THE OWNER FOR FUTURE INSTRUCTION ON METHODS FOR REDUCING THE RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO SMART SMR ONE COMPLETE SET OF PRINTS SHOWING "INSTALLED WORK". 8. UTILITY SERVICE A. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL CONFORM TO THE REQUIREMENTS OF THE SERVING UTILITY COMPANIES. CONTRACTOR SHALL VERIFY SERVICE LOCATIONS AND REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BY THE SERVING UTILITIES. B. CONFORM TO ALL REQUIREMENTS OF THE SERVING UTILITY COMPANIES. 9. PRODUCTS A. ALL MATERIALS SHALL BE NEW, CONFORMING WITH THE NEC, ANSI, NEMA, AND THEY SHALL BE U.L. LISTED AND LABELED. B. CONDUIT: 1. RIGID CONDUIT SHALL BE U.L. LABEL GALVANIZED ZINC COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN INSTALLED IN OR UNDER CONCRETE SLABS, IN CONTACT WITH THE EARTH, UNDER PUBLIC ROADWAYS, IN MASONRY WALLS OR EXPOSED ON BUILDING EXTERIOR, RIGID CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAPPED WRAPPED WITH HUNTS WRAP ROCESS NO. 3. 2. ELECTRICAL METALLIC TUBING SHALL HAVE U.L. LABEL, FITTINGS SHALL BE COMPRESSION TYPE. EMT SHALL BE USED ONLY FOR INTERIOR RUNS. 3. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE PERMITTED BY CODE. FITTINGS SHALL BE "JAKE" OR "SQUEEZE" TYPE. SEAL TIGHT FLEXIBLE CONDUIT. ALL CONDUIT IN EXCESS OF SIX FEET IN LENGTH SHALL HAVE FULL SIZE GROUND WIRE. 4. CONDUIT RUNS MAY BE SURFACE MOUNTED IN CEILING OR WALLS UNLESS INDICATED OTHERWISE. CONDUIT INDICATED SHALL RUN PARALLEL OR AT RIGHT ANGLES TO CEILING, FLOOR OR BEAMS. VERIFY EXACT ROUTING OF ALL EXPOSED CONDUIT WITH ARCHITECT PRIOR TO INSTALLING. 5. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE) AT A MINIMUM DEPTH OF 24" BELOW GRADE. 6. ALL CONDUIT ONLY (C.O.) SHALL HAVE PULL ROPE. 7. CONDUITS RUN ON ROOFS SHALL BE INSTALLED ON 4 X 4 SLEEPERS, 6'-0" ON CENTER, SET IN NON-HARDENING MASTIC. C. ALL WIRE AND CABLE SHALL BE COPPER, 600 VOLT, #12 AWG MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED. TYPE THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN CONDUIT EXPOSED TO WEATHER, IN WHICH CASE TYPE THWN INSULATION SHALL BE USED. D. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES SIZED PER CODE TO ACCOMMODATE ALL DEVICES AND WIRING. E. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE WITH WHITE FINISH (UNLESS NOTED BY ARCHITECT/ENGINEER), 20 AMP, 125 VOLT, THREE WIRE GROUNDING TYPE, NEMA 5-20R. MOUNT RECEPTACLE AT +12" ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED ON DRAWINGS OR IN DETAILS. WEATHERPROOF RECEPTACLES SHALL BE GROUND FAULT INTERRUPTER TYPE WITH SIERRA #WPD-8 LIFT COVERPLATES. F. TOGGLE SWITCHES SHALL BE 20 AMP, 120 VOLT AC, SPECIFICATION GRADE WHITE (UNLESS NOTED OTHERWISE) FINISH. MOUNT SWITCHES AT +48" ABOVE FINISHED FLOOR. G. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE WITH ANTI-BURN SOLDERLESS COMPRESSION APPROVED FOR COPPER CONDUCTORS, COPPER BUS BARS, FULL SIZED NEUTRAL BUS, GROUND BUS AND EQUIPPED WITH QUICK- MAKE QUICK-BREAK BOLT-IN TYPE THERMAL MAGNETIC CIRCUIT BREAKERS. MOUNT TOP OF THE PANELBOARDS AT 6'-3" ABOVE FINISHED FLOOR. PROVIDE TYPEWRITTEN CIRCUIT DIRECTORY. H. ALL CIRCUIT BREAKERS, MAGNETIC STARTERS AND OTHER ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED. I. GROUND RODS SHALL BE COPPER CLAD STEEL, 5/8" ROUND AND 10' LONG. COPPERWELD OR APPROVED EQUAL. 10. INSTALLATION A. PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL EQUIPMENT, FIXTURES, BOXES, PANEL, ETC., SUPPORT LUMINARIES FROM UNDERSIDE OF STRUCTURAL CEILING, EQUIPMENT SHALL BE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCE WITH STATE AND LOCAL CODE REQUIREMENTS. PROVIDE PRIOR ALIGNMENT AND LEVELING OF ALL DEVICES AND FIXTURES. B. CUTTING, PATCHING, CHASES, OPENINGS: PROVIDE LAYOUT IN ADVANCE TO ELIMINATE UNNECESSARY CUTTING OR DRILLING OF WALLS, FLOORS CEILINGS, AND ROOFS. ANY DAMAGE TO BUILDING STRUCTURE OR EQUIPMENT SHALL BE REPAIRED BY THE CONTRACTOR. OBTAIN PERMISSION FROM THE ARCHITECT/ENGINEER BEFORE CORING. C. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC., IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND/OR REINFORCING STEEL WILL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY CIRCUMSTANCES. D. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT DEFINITELY KNOWN AND THEREFORE, MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIA X-RAY OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR STEEL TENDONS. E. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH THE REQUIREMENTS OF THE U.B.C. 11. PROJECT CLOSEOUT A. UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL POTENTIAL GROUNDING TESTS FOR APPROVAL. SUBMIT TEST REPORTS TO PROJECT MANAGER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK IN A COMPLETE AND UNDAMAGED CONDITION. B. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE ELECTRICAL "AS INSTALLED" DRAWINGS AT THE COMPLETION OF THE JOB, SHOWING ACTUAL DIMENSIONS, ROUTINGS AND CIRCUITS. C. ALL BROCHURES, OPERATING MANUALS, CATALOG, SHOP DRAWINGS, ETC., SHALL BE TURNED OVER TO OWNER AT JOB COMPLETION. 2ELECTRICAL NOTES 1. EQUIPMENT POWER SHALL BE 200A, 1Ø, 3W, 120/208V OR 120/240V. 2. UTILITY RECEPTACLE IS A GFCI DUPLEX OUTLET INSTALLED IN THE DEADFRONT OF PPC. 3. PROVIDED A MIN. 36" WORK CLEARANCE IN FRONT OF PANELS / SERVICE EQUIPMENT. 4. ALL BREAKERS IN THE ELEC. PANEL ARE RATED 10,000 RMS SYMMETRICAL AMPS, 240V MAX. 75°C. 5. ALL WIRING SHALL BE COPPER 75°C U.N.O. 6. CONDUIT REQUIREMENTS (TYP., U.N.O.) UNDERGROUND: PVC (SCHED 40 OR 80) INDOOR: EMT (RGS IN TRAFFIC AREAS) OUTDOOR: RGS (ABOVE GRADE) 7. APPLETON EMERGENCY GENERATOR PLUG AT 36" A.F.F. CONTRACTOR TO VERIFY EXACT LOCATION WITH LANDLORD AND UTILITY COORDINATOR. 8. PLACE "TRUE TAPE" AND PULL ROPE IN THE CONDUITS AS REQUIRED. LANDLORD SIGNATURE REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF E-2 ELECTRICAL PLAN, PANEL SCHEDULE, & DIAGRAMS 2 PANEL SCHEDULE 5 2 E-2 AC POWER WIRING DIAGRAM NOTES : 1. ALL EQUIPMENT (FUSES, CIRCUIT BREAKERS, BUSSING, ETC.) SHALL HAVE A SHORT CIRCUIT RATING EQUAL TO, OR GREATER THAN, THE AVAILABLE SHORT CIRCUIT CURRENT AT THE LOCATION. 2. ALL ELECTRICAL EQUIPMENT SHALL BE U.L. LISTED. 3. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER SHALL BE LISTED FOR EXTERIOR USE. 4. SQUARE "0" NOOD PANELBOARD 5. CU-2 SHALL OPERATE ONLY IF CU-1 IS DISCONNECTED FROM POWER BY AUTOMATIC CONTROLS. 6. MULTIPLE CIRCUITS NEED COMMON "OFF" HANDLE CUPS. EQUIPMENT ELECTRICAL PLAN 1 LANDLORD SIGNATURE VOLTS : 120 / 240V PHASE : 1 Ø WIRE : 3 PANEL SCHEDULE 3ONE LINE DIAGRAM ALARM WIRING DIAGRAM 4 AL1 DOOR ALM RTN AL2 DAC ALM RTN AL3 HTR ALM RTN AL4 DC ALM RTN AL5 DC MAL RTN AL6 AC PWR HULOW RTN AL7 BAT CAB DOOR RTN AL8 BAT CAB DAC RTN AL9 BAT CAB CBALM RTN AL10 RTN AL11 RTN AL12 RTN DC ALM DC MIN DC MAJ AC MAINS HI /LOW ALARM AL3 ALARM CABLE PIN AL3 RTN AL4 AL4 RTN AL5 AL5 RTN BLUE BLU/WHT ORANGE ORG/WHT GREEN GRN/WHT K10-NC K10-C K11-NC K11-C K9-NC K9-C 73 74 76 77 70 71 GRN/WHT GRN ORG/WHT ORG BLU/WHT BLU BLK RED BLK RED BLK RED 70 71 73 74 76 77 GRN BLU ORG DC ALARM WIRING CODEX ALARM MODULE INSIDE FRONT DISTRIBUTION COVER HEATER DOOR OPEN DETECT SWITCH BLK RED C NC NC 1 2 C NC NC DOOR ALARM SWITCH BLK RED HEAT J8 J9 J7 J6 J3 J2J4 COOLSW1 J8 J9 J7 J6 J3 J2J4 J1 DOOR ALARM DAC ALARM 1 HEATER ALARM 1 DC POWER ALARM 1 ALARM CABLE 1 SW1 K 11K 10K 9 BLACK RED L2L1 FIELD WIRING 24OVAC SINGLE PHASE 60Hz 200A MAX TO CAB MGB DCPP REAR VIEW AC POWER CONNECTIONS SHELF 2 SHELF 1 BLK RED L1 L2 MDL 1&2 TO HEATER RELAY BLK RED L1 L2 MDL 1&2 BLK RED 3 GREEN WIRES 240VAC DINRAIL ASSEMBLY 3 BLK10A 10A 10A ON ON ON ON BLK RED L1 L2 BLK RED L1 L2MDL 3&4 MDL 5 MOL 5 MDL 3&4 G BLK RED L1 L2 BLK RED L1 L2 2GRN GRNG G GGRN GRN UPPER LEVEL TERMINALS LOWER LEVEL TERMINALS EXPANSION CABINET BATTERY HEATER OPT CABINET HEATER ON ON 2 2 2 2 2 REDBLKBLKREDREDDC PP ALM RLY GRN/ WHT BLU/ WHT ORG/ WHT (BROWN PAIR NOT USED) HEATER ALARM DAC ALARM J1 N EXISTING T-MOBILE TELCO BOARD EXISTING T-MOBILE UTILITY PANEL EXISTING T-MOBILE ELEC. PANEL EXISTING T-MOBILE EQUIPMENT SHELTERNEW T-MOBILE HCS 2.0 JUNCTION BOXES ON EXISTING UNISTRUTS ON WALL (3 TOTAL) 1 A-9 15'-0"10'-0" EXISTING COAX CABLE STUB UPS NEW T-MOBILE HPL3 600A SSC CABINET WITH 1 CSR IXRe ROUTER, 2 VOLTAGE BOOSTER, 2 AMIA, 2 ASIB, 2 ASIK, 3 ABIA, 5 ABIL, AND 3 ABIC INSIDE CABINET 5 A-6 NEW T-MOBILE LB3 BATTERY CABINET 6 A-6 1'-6" MIN. 1 A-7 2 A-7 3 A-7 4 A-7 5 A-7 6 A-7 7 A-7 NEW T-MOBILE CAC PANEL ON EXISTING WALL 8 A-7 NEW T-MOBILE CUBE ON EXISTING WALL 9 A-7 10 A-7 NEW 3"Ø RIGID CONDUIT AT ±10' (2 TOTAL) AND NEW 3"Ø RIGID CONDUIT AT ±5' (1 TOTAL) REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF ELECTRICAL DIAGRAMS 39DC HEATING AND COOLING WIRING DIAGRAM 2 1 E-3 "TIER" 1 "TIER" 2 DAC DOOR PWR 25A FUTURE USE 10A FUTURE USE 10A FUTURE USE 10A FRONT 1 BLK RED 1 REAR 1212 JUMPER OBSERVE CORRECT ALARM PIN ORIENTATION "TIER" 3 "TIER" 4 FUTURE USE FUTURE USE FUTURE USE MID TRIP ALM 25ADC POWER WIRING DIAGRAM DC CABINET DOOR LIGHT POWER WIRING DIAGRAM DC POWER WIRING DIAGRAM LIGHT ASSEMBLY RED BLK RED BLK BLK BLK RED BLK 2 C C NC NC NC NC 1 TO DOOR UPPER FAN V+ V- V+ V- V + RED RED RED V -48 BLACK BLACK BLK BLK RED TO LED LIGHTUPPER FAMLOWER FAMCAB LIGHTCOOL CONTROLLERHEAT CONTROLLER15A15A5A5A5ARED BLACK BLACK BLACK RED RED J7 J8 COOL COOL J8 J7 J8 J3 J2 SW1 J1 SW1 J1 HEAT DAC (COOLING) CONTROLLER FUNCTION PIWR IN DELTA T JUMPER OUTSIDE TEMPERATURE DACFAN (LOWER) DACFAN (UPPER) ALARM COOLING INHBIT HEAT REQUEST HEATER CONTROLLER COHN FUNCTION JI PIWR IN J8 J9 J7 UNUSED J6 HEATER FAN J3 J2 J4 ALARM COOLING INHBIT HEAT REQUEST DOOR SW INPUT HEATER REALY CONTROL MID TRIP ALM 10AMID TRIP ALM 10AMID TRIP ALM 10ATHERMAL SYSTEM DAC AND HEATER MID TRIP ALM 25AMID TRIP ALM 10AMID TRIP ALM 10AMID TRIP ALM 10AFUTURE USE FUTURE USE FUTURE USE THERMAL SYSTEM DAC AND HEATER MID TRIPALM 10A MID TRIPALM 10A CB AMARM PIN AND SWITCH ORIENTATION "OFF" JUMPER CB AMARM PIN AND SWITCH ORIENTATION "OFF" JUMPER CB AMARM PIN AND SWITCH ORIENTATION "OFF" JUMPER CB AMARM PIN AND SWITCH ORIENTATION "OFF" NOTE: DIAGRAMS PROVIDED ARE PER MANUFACTURER INSTALLATION GUIDE DC DISTRIBUTION TERMINALS "TIER" 1 OF 4 (SIDE VIEW) DC DISTRIBUTION-DOOR OPEN FROM VIEW DC-48V HOT BUS (CB FROTECTED) DC RETURN BUS OV (+) TO CABINET DC FUSE BLOCK FROM DIN DISTRIBUTION TO HEAT CONTROLLER LIGHT SWITCH DOOR OPEN DETECT FROM DC PLANT 25A DC DISTRIBUTION (BLACK WIRE JUMPERS TO FUSE POSOTIONS REMOVED FOR CLARITY) TO DOOR LOWER FAN COHN JI J8 J9 J7 J6 J3 J2 J4 FROM DC DIN DISTRIBUTION FROM DOOR FROM DC DIN DISTRIBUTION FROM DOOR DOOR OPEN DETECT TO HEATER ELEMENT ACPWR FROM CIRCUIT BREAKER HEATER ALARM DAC ALARM TO CABINET ALARM BLOCK J9 J9 J4 J8 J7 J8 J3 J2J9 J4 LANDLORD SIGNATURE REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF G-1 GROUNDING PLANS NOTES & LEGEND NOTE: 1. CONTRACTOR TO REPLACE ALL MISSING GROUND BARS AND GROUNDING CONNECTIONS AS REQUIRED. EXOTHERMIC CONNECTION MECHANICAL CONNECTION EQUIPMENT GROUND BAR ANTENNA GROUND BAR (AS REQUIRED) #2 AWG GROUND LEAD (AS REQUIRED) LEGEND ELECTRICAL GROUNDING SPECIFICATIONS 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING JURISDICTION. 2. ALL GROUNDING DEVICES SHALL BE U.L. LISTED FOR THEIR INTENDED USE. 3. GROUND WIRES SHALL BE TINNED #2 AWG BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4. CONNECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED), UNLESS OTHERWISE NOTED. AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND T-MOBILE WIRELESS BROADBAND STANDARDS. 5. GROUNDING CONDUCTORS SHALL BE ROUTED ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. WHEN REQUIRED, GROUND LEADS SHALL BE BENT TO A MINIMUM OF 8" RADIUS. 6. WHERE GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO THE GROUND RING. INSTALL WIRE IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5" BELOW GRADE AND SEAL THE TOP WITH SILICONE SEALANT. 7. ALL GROUND BARS SHALL BE TINNED, 1/4" COPPER, SECTOR BARS 2", COLLECTOR AND MGB BARS 4", OF SUFFICIENT LENGTH TO ACCOMMODATE ALL REQUIRED CONNECTIONS WITHOUT DOUBLING LUGS, AND EACH INSTALLED WITH ISOLATORS. WHEN CONNECTING GROUND BARS (WITHIN 10 FEET OF GRADE) DIRECTLY TO THE GROUND RING, 2 EA. #2 SOLID DOWNLEADS SHALL BE CAD-WELDED TO THE GROUND BAR, 1 AT EACH OPPOSITE BOTTOM CORNER, AND EACH SHALL RUN IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM GROUND BAR DOWN TO THE GROUND RING. WHEN CONNECTING SECTOR GROUND BARS, DAISY-CHAIN THE GROUND BARS AND RUN 1 EA. #2 AWG STRANDED COPPER WIRE WITH THWN INSULATION FROM THE MIDDLE GROUND BAR TO THE GROUND RING AND CAD-WELD TO THE RING. 8. WHEN ATTACHING STRANDED GROUND LEADS TO THE GROUND BARS, 2 HOLE COMPRESSION LUGS SHALL BE USED, PROTECT WITH WEATHERPROOF HEAT SHRINK, AND WITH A THIN COAT OF "KOP'R SHIELD" OR EQUIVALENT PROPERLY APPLIED AND ATTACHED ONLY WITH STAINLESS STEEL HARDWARE. 9. WHEN GROUNDING EQUIPMENT ENCLOSURES, PANELS, FRAMES, AND OTHER METAL APPARATUS, A #6 AWG STRANDED COPPER WIRE WITH THWN INSULATION SHALL BE ATTACHED UTILIZING A 2 HOLE COMPRESSION TYPE LUG, PROTECTED WITH WEATHERPROOF HEAT A CLEAN AND CORROSION FREE METALLIC SURFACE UTILIZING STAINLESS STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE 10 BELOW. 10. PREPARE ALL BONDING SURFACES FOR GROUND CONNECTIONS BY REMOVING ANY AND ALL PAINT AND CORROSION TO SHINY METAL. FOLLOWING CAD-WELDED CONNECTIONS TO NON-COPPER SURFACES, APPLY ONE COAT OF ANY ANTI-OXIDIZING PAINT, "COLD GALV" OR EQUIVALENT. 11. GROUND RODS SHALL BE COPPER-CLAD STEEL 5/8"x10', SPACED NO LESS THAN 10' ON CENTER. 12. ALL GROUND SYSTEM CONDUCTORS AND CONDUITS SHALL BE SECURED UTILIZING ONLY NONMETALLIC, NON-CONDUCTIVE, UV RATED CLAMPS, BRACKET, AND OR SUPPORTS. 13. WHEN REQUIRED, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT TESTING FIRM TO VERIFY, UTILIZING A MEGGER TEST, THAT THE RESISTANCE TO EARTH OF THE NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 5 (OHMS). A COPY OF THE COMPLETE TESTING REPORT SHALL BE PROVIDED TO THE T-MOBILE REPRESENTATIVE. 14. ALL MATERIALS AND HARDWARE SHALL BR INSTALLED IN A WORKMAN-LIKE MANNER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND DEFINED IN NFPA-70 AND APPROVED BY A,H,J, N 1 3 EQUIPMENT GROUNDING 2 N ANTENNA GROUNDING LANDLORD SIGNATURE 3 G-2 NEW MECHANICAL LUG CONNECTION (TYP.) 2 G-2 (E) GROUND BAR (FIELD VERIFY LOCATION) (TYP) 4 G-2 NEW MECHANICAL LUG CONNECTION (TYP.) 2 G-2 (E) GROUND BAR (FIELD VERIFY LOCATION) (TYP) NEW #6 AWG FROM JUNCTION BOXES TO (E) GROUND BAR (TYP.) 4 G-2 3 G-2 NEW #6 AWG FROM CABINET TO (E) GROUND BAR (TYP.) 4 G-2 3 G-2 NEW #6 AWG FROM ANTENNA TO (E) GROUND BAR (TYP.) 3 G-2 NEW #6 AWG FROM PENDANT TO (E) GROUND BAR (TYP.) 3 G-2 NEW #6 AWG FROM AHLOA TO (E) GROUND BAR (TYP.) 3 G-2 NEW #6 AWG FROM AHFIG TO (E) GROUND BAR (TYP.) NEW #6 AWG FROM CUBE TO (E) GROUND BAR (TYP.) 4 G-2 NEW #6 AWG FROM CAC PANEL TO (E) GROUND BAR (TYP.) 4 G-2 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF GROUNDING DETAILS TYPE VV TYPE GT TYPE TA TYPE GY TYPE GR TYPE VN TYPE NC TYPE VS TYPE VB TYPE SS TYPE PT NOTE: ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 EXOTHERMIC WELDING NOT USED TWO-HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4" STAINLESS STEEL HEX UNIT BOLTS AND HARDWARE. EXISTING 4"x12"x1/4" THK., TINNED GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWER SECTOR GROUND BAR EXOTHERMIC WELD EXISTING #2 AWG SOLID TINNED BARE Cu WIRE TO EXISTING TOWER GROUND BAR OR MAIN GROUND BAR NOTES: 1. PROVIDE NO-OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR 2. CONTRACTOR WILL VERIFY BUSS BAR GROUNDING TO THE TOWER OR RING. 3. GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. 12" TO 24" CABLE GROUNDING 2 1/2"ØMAX.ANTENNA CABLE CABLE GROUND KIT ANTENNA AND/OR GPS CABLE CONNECTION NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT TYPE SHALL BE APPROVED BY TMO PRIOR TO INSTALLATION 3. WEATHERPROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT, COLD SHRINK SHALL NOT BE USED. #6 AWG STRANDED Cu WIRE WITH GREEN, 600V,THWN INSULATION OR BLACK (GROUNDED TO GROUND BAR) CABLE CONNECTOR WEATHERPROOFING KIT (SEE NOTE 3) 3" MIN. NOTES: 1. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER, GROUND BAR, GROUND LUG, FLAT WASHER, LOCK WASHER AND NUT. 2. COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT SHALL BE PLACE WHERE ALL DISSIMILAR METALS CONNECT. 3. ALL LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4. ALL LUGS MUST HAVE INSPECTION WINDOWS.BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) BARE WIRE TO BE NO-OX AT BOTH ENDS GROUNDING CONDUCTOR HEAT SHRINK (CLEAR HEAT SHRINK INDOOR & BLACK HEAT SHRINK OUTDOOR) NUT (TYP.) BOLT (TYP.) GROUND BAR WIRE SIZE #6 AWG GREEN INSULATED #2 AWG SOLID TINNED #2 AWG STRANDED #2/0 AWG STRANDED #4/0 AWG STRANDED YA6C-2TC38 YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N 1/2" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT BURNDY LUG BOLT SIZE MECHANICAL LUG FLAT WASHER (TYP.) FLAT WASHER (TYP.) LOCK WASHER (TYP.) BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) MAIN GROUND BAR EXISTING MAIN GROUND BAR EXISTING #6 AWG STRANDED Cu WIRES TO EXISTING EQUIPMENT TWO-HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4"STAINLESS STEEL HEX UNIT BOLTS AND HARDWARE. NOTES: 1. PROVIDE NO-OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR 2. CONTRACTOR WILL VERIFY BUSS BAR GROUNDING TO THE TOWER OR RING. 3. GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. EXOTHERMIC WELD EXISTING (2) #2 AWG SOLID TINNED BARE Cu WIRE TO EXISTING GROUND RING NOT USED NOT USED 1 2 3 4 5 6 8 10 11 12 NOT USED 9 NOT USED NOT USED NEW CABINETS AND JUNCTION BOXES GROUNDING KIT: #6 AWG STRANDED Cu WIRE WITH GREEN, 600V, THWN INSULATION OR BLACK ANTENNA, AHLOA, AHFIG, AND PENDANTS GROUNDING KIT: #6 AWG STRANDED Cu WIRE WITH GREEN, 600V,THWN INSULATION OR BLACK G-2 REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF RF-1 RF DETAILS RF DETAILS 1RF DETAILS 1 LANDLORD SIGNATURELANDLORD SIGNATURE ANTENNA AND COAX GENERAL NOTES: 1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY T-MOBILE AND INSTALLED BY CONTRACTOR. 2. COAX COLOR CODING: ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER FROM TRUE NORTH AND COLOR CODED AS FOLLOWS. 3. THE ABOVE COAX COLOR CODING APPLIES TO SECTORIZED SITES. FOR OMNI SITES, USE THE AT0, BT0, & GT0 COLOR CODES ONLY. 4. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHER PROOF COLORED VINYL TAPE AT THE FOLLOWING LOCATIONS: x #1 - AT ANTENNA CONNECTION x #2 - AT ENTRY TO EQUIPMENT CABINET 5. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK & 12" FROM EDGE OF EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE), UP TO TOWER LEG (IF APPLICABLE), & DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE ACCORDING TO ELECTRICAL DRAWINGS. VERIFY NUMBER OF ANTENNAS, CABLE, & CABLE DIAMETER WITH PROJECT MANAGER. 6. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHER PROOFED. 7. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY. 8. TAGGING: x ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. x COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING.) 9. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0" ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. 10. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY FROM CONNECTION (STEP 9). 11. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES AND TMA'S. HEAT SHRINK SHALL BE "CANUSA" WITH ADHESIVE. CONNECTORS (TYP.) 1"1"2"2"4"4" ELECTRICAL TAPE (1 LAYER) BUTYL TAPE (ALSO KNOWN AS MASTIC, TAFFY TAPE) ELECTRICAL TAPE: 3 LAYERS WITH 2" TAPE AND 3 LAYERS IN 3/4" TAPE (ALL WITH MINIMUM 50% OVERLAP). ALL TAPE ENDS SHALL BE CUT (DO NOT STRETCH). COAT WITH 3M SCOTCHKOTE SPRAY SEALER STEP 1 STEP 2 STEP 3 STEP 4 COAXIAL CABLE WEATHERPROOFING NOTE: 1. ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS, MOUNTING HARDWARE, AND RF DESIGN. BASED ON RFDS VERSION 7 DATED: 06/26/2020 TRANSMISSION CABLE ANTENNA SCHEDULE-FINAL CONFIGURATION SIZEQTY.LENGTH SECTOR (COLOR)ANTENNA MODEL ANTENNA AZIMUTHPORTPOSITION ALPHA (RED) BETA (GREEN) GAMMA (BLUE) EXISTING/ NEW MANUFACTURER DIMENSIONS (LxWxD) WEIGHT (LBS) RAD CENTER TYPE A1 B1 OCTO C1 NEW 89.8'0° NEW 110° NEW 260° OCTO OCTO COMMSCOPE FFVV-65C-R3-V1 95.9" x 25.2" x 9.3" 124.6 (2)15'.5"Ø HCS 2.0 JUMPER 150'1.5"Ø(1) 15'.5"Ø HCS 2.0 JUMPER(1)92.3'A2 B2 C2 NEW NEW NEW MIMO MIMO MIMO (2) 15'.5"Ø HCS 2.0 JUMPER 15'.5"Ø HCS 2.0 JUMPER(1) (2)15'.5"Ø HCS 2.0 JUMPER 15'.5"Ø HCS 2.0 JUMPER(1) AEHCNOKIA 38.2" x 5.9" x 21.5" 108.0 COMMSCOPE FFVV-65C-R3-V1 95.9" x 25.2" x 9.3" 124.6 AEHCNOKIA 38.2" x 5.9" x 21.5" 108.0 COMMSCOPE FFVV-65C-R3-V1 95.9" x 25.2" x 9.3" 124.6 AEHCNOKIA 38.2" x 5.9" x 21.5" 108.0 0° 89.8' 92.3' 89.8' 92.3' 110° 260° DELTA (YELLOW)D1C1 NEW 180°OCTO (2)15'.5"Ø HCS 2.0 JUMPERCOMMSCOPE FFVV-65C-R3-V1 95.9" x 25.2" x 9.3" 124.689.8' HCS 2.0 TRUNK 150'1.5"Ø(1)HCS 2.0 TRUNK 150'1.5"Ø(1)HCS 2.0 TRUNK REV DESCRIPTIONDATE BYREV DESCRIPTIONDATE BY IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. JURISDICTION APPROVAL STAMP DEPARTMENT FOR LAND USE DEPARTMENT FOR BUILDING & CONSTRUCTION 19807 NORTH CREEK PARKWAY NORTH BOTHELL, WA 98011 R ARCHITECTURE & ENGINEERING 2667 CAMINO DEL RIO SOUTH, STE. 205 SAN DIEGO, CA 92108NOT FOR CONSTRUCTIONPNW MARKET OFFICE 9725 3RD AVENUE NE, STE. 410 SEATTLE, WA 98115 ALDERBROOK /PSE /CONTORA A 06/09/2020 ANCHOR + L600 90%CD MGM 0 07/10/2020 ANCHOR + L600 100%CD VF RF-2 RF DIAGRAM RF DIAGRAM 11 LANDLORD SIGNATURELANDLORD SIGNATURE NOTE: BASED ON RFDS VERSION 7 DATED: 06/26/2020 NOTE: JDSU AND EXFO GEAR CAN BE USED TO READ WAVELENGTH ON THE SFPs. NOKIA ITEM CODE/SECTOR PRODUCT NAME 474335A FOCZ QSFP+ 4x10 km SM 474385A FOUF SFP+ 10GBASE-LR 1271 nm CWDM 10 km SM 474386A FOUG SFP+ 10GBASE-LR 1291 nm CWDM 10 km SM 474387A FOUH SFP+ 10GBASE-LR 1311 nm CWDM 10 km SM 474388A FOUI SFP+ 10GBASE-LR 1331 nm CWDM 10 km SM 474829A AOSB QSFP28 SM 10 km LC FTLX1370W4BTL SM SFP 1310 nm CPRI 9.8G 1.4km (CPRI) 473471A FOTA Optical SFP+ 10GBase-SR 850nm MM FTLX8573D3BTL 10Gb/s 850nm Multimode SFP+ Datacom Transceiver x 2 x 2 x 2 x 1 x 1 x 2 x 4 x 3 x 3 AHFIB/AHFIG AAHF SFC4_1 SFC4_2 LTE FDD-eNB1 LTE TDD-eNB2 NR TDD-gNB IXR-e OPT2 OPT1 OPT1 OPT2 OPT3 FOCZ IN OUT AOSB ABILABICABIA FOUF FOUI FOUF FOUG FOTA FTLX8573D3BTL FTLX8573D3BTL FTLX8573D3BTL NR - LEFT SIDE ANTENNA LTE - RIGHT SIDE ANTENNA FOTA ASIA FOTA ASIKASIB FTLX1370W4BTL FOUG FOUH x PORT CONNECTION ON THE ABIA MAY VARY AND ARE DESIGNATED AS RFx ('x' CAN BE 1-6) x AHFIB/AHFIG IS ON SAME ABIA