Loading...
20-103656-Structural Calculations-09-56-2020-V1Morrison Hershfield Ms. Jessica Pierce Morrison Hershfield Ryka Consulting 1455 Lincoln Parkway, Suite 500 5628 Airport Way South, Suite 112 Atlanta, GA 30346 Seattle, WA 98108 (770) 379-8500 (206) 523-1941 Date: September 22, 2020 Subject: Rigorous Structural Analysis Report Carrier: T-Mobile Carrier Site Number: SE04653A Carrier Site Name: LAKOTA PARK Site Address: 31334 SW Dash Point Road, Federal Way, King County, WA 98023 Site Coordinates: Latitude: 47° 19' 13.6" N, Longitude: 122° 21' 37.2" W Tower Description: 91.5 ft – Monopole Tower [Ehresmann] Morrison Hershfield Project Number: TMB-185R2 / 2021192 Dear Ms. Pierce, Morrison Hershfield is pleased to submit this “Rigorous Structural Analysis Report” to determine the integrity of the above mentioned tower structure for the existing and proposed antenna and equipment noted. This rigorous analysis has been performed in accordance with the 2015 International Building Code based upon an ultimate 3-second gust wind speed of 110 mph converted to a nominal 3-second gust wind speed of 85 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C with a maximum topographic factor, Kzt, of 1.0 and Risk Category II were used in this analysis. Our analysis demonstrates that the existing tower and foundation ARE in conformance with the requirements of the above noted standards under the effects of loading described. Summary of Results Tower Structure 39.4% Sufficient Base Foundation 34.4% Sufficient We at Morrison Hershfield appreciate the opportunity of providing our continuing professional services to you and Ryka Consulting. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: Morrison Hershfield Shawn W. Stevenson, S.E. (WA License No. 42002) Senior Engineer 91.5 ft – Monopole Tower – Rigorous Structural Analysis Report September 22, 2020 Project Number: TMB-185R2 / 2021192 Page 2 1.0 INTRODUCTION This tower is a 91.5 ft monopole tower designed by Ehresmann Engineering, Inc., in March of 2016. The tower was originally designed for a basic wind speed of 100 mph and 0.5 inch radial ice thickness per TIA-222-G Standard. 2.0 ANALYSIS CRITERIA The following design parameters have been used in our analysis: Design Standard: 2015 International Building Code ANSI/TIA-222-G, Structural Standard for Antenna Supporting Structures and Antennas ASCE 7-10, Minimum Design Loads for Buildings and Other Structures AISC 325-15, Manual of Steel Construction ACI 318‐14, Building Code Requirements for Structural Concrete ANSI/AWS D1.1-11, Structural Welding Code - Steel Design Wind Speed: 110 mph (Ultimate 3-sec gust) with no radial ice 85 mph (Nominal 3-sec gust) with no radial ice Risk Category: II Exposure Category: C Topographic Factor, Kzt: 1.0 Design Ice Thickness: 0.25 in Wind Speed with Ice: 30 mph (Nominal 3-sec gust) Seismic SS: 1.311 Seismic S1: 0.504 Service Wind Speed: 60 mph (Nominal 3-sec gust) The structural analysis was based on the following documentation: Table 1 – Documentation Document Description Source Geotechnical Report ADaPT Engineering, Inc., Job No. WA00-4637, dated 07/26/2000 Client Tower & Foundation Design Ehresmann Engineering, Inc., Job No. 96430, dated 03/18/2016 Client Final Construction Drawings Morrison Hershfield, Site ID: SE04653A, dated 09/21/2020 MH RF Data Sheet T-Mobile, Site ID: SE04653A, dated 08/31/2020 Client 91.5 ft – Monopole Tower – Rigorous Structural Analysis Report September 22, 2020 Project Number: TMB-185R2 / 2021192 Page 3 3.0 ANALYSIS LOADING The existing and proposed antennas, transmission lines and other equipment considered in this analysis were provided by the client and are noted in Table 2. Table 2 – Antenna Loads Notes: 1) Proposed equipment is in addition to the remaining existing equipment at the given elevation. 2) Existing equipment that is to remain on the tower. 3) Existing equipment that is to be removed from the tower and has not been considered in this analysis. MCL (ft) ACL (ft) QTY. Antenna/Appurtenance Description Carrier QTY. TX-Lines Notes PROPOSED 87.5 87.5 3 Andrew HBXX-6517DS-A2M Panel T-Mobile 6 2 7/8” HCS 2.0 Pendant 1 3 CommScope FFVV-65C-R3-V1 Panel 3 Nokia AEHC Panel 3 Nokia AHFIG RRH 3 Nokia AHLOA RRH 3 CommScope TMAT1921B68-21-43 TMA EXISTING 87.5 87.5 3 12 ft T-Arm Mount T-Mobile - - 2 3 Andrew SBNHH-1D65C-SR Panel 1 HCS 1.0 3 3 Nokia FRIJ RRH 3 Nokia FRLB RRH 2 Nokia FXFB RRH 12 CommScope ECC1920-VPUB Diplexer 1 Nokia NSN COVP 81.0 81.0 3 24” Stadium Light - 1 3/4" DC 2 78.0 78.0 3 24” Stadium Light 75.0 75.0 3 24” Stadium Light 91.5 ft – Monopole Tower – Rigorous Structural Analysis Report September 22, 2020 Project Number: TMB-185R2 / 2021192 Page 4 4.0 ANALYSIS LOADING The existing and proposed antennas, transmission cables, antenna mounts and other equipment considered in this analysis were provided by the client and are noted in the attachments. 5.0 ANALYSIS PROCEDURE tnxTower (Version 8.0.7.5), a commercially available analysis software package, was used to create a three- dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is attached at the end of this report. 6.0 ASSUMPTIONS The analysis provided by Morrison Hershfield is based on the theoretical capacity of the structure and is not a condition assessment of the tower. Morrison Hershfield has not performed an engineering inspection of the tower and the analysis was completed based on information supplied by the client. Morrison Hershfield has not made any independent determination of the accuracy of the information provided. 1) Tower and structures were built in accordance with the manufacturer’s specifications and the applicable ANSI/TIA/EIA standard. 2) The tower and structures have been maintained in accordance with the manufacturer’s specification. 3) The tower is assumed to be in good condition and capable of supporting its full design capacity. 4) The foundation was properly designed and constructed for the original design loads. 5) The configuration of antennas, transmission cables, antenna mounts and other appurtenances are as specified in the attached Site Inventory Analysis Sheet and the referenced documents. 6) All existing/proposed antennas and antenna mounts are assumed to be adequate for the existing/proposed loads. Analysis of these antennas and antenna mounts is considered to be outside of the scope of this analysis. Morrison Hershfield has not performed an analysis of the existing/proposed antennas or antenna mounts. 7) The existing and proposed loading are taken from the RF Data Sheet by T-Mobile, Site ID: SE04653A, dated 08/31/2020 and from the Final Construction Drawings by Morrison Hershfield, Site ID: SE04653A, dated 09/21/2020, and are considered to be correct. 8) Two foundation options were provided in the original foundation drawings, and we have evaluated both options (#1 Pad & Pier and #2 Drilled Pier) in this analysis. If any assumptions are not valid or have been made in error, this analysis is invalid. Morrison Hershfield should be notified to determine the effect on the structural integrity of the tower. 91.5 ft – Monopole Tower – Rigorous Structural Analysis Report September 22, 2020 Project Number: TMB-185R2 / 2021192 Page 5 7.0 SUMMARY OF RESULTS The following tables summarize the location and utilized percentage of available capacity for each component of the tower. With consideration to the appropriate safety factors, 100% represents the full capacity of the component. Percentages below 100% indicate available capacity and conformance of the component. Percentages between 100% and 105% indicate an acceptable capacity. Percentages above 105% indicate an overstressed situation requiring structural modification to ensure conformance with the applicable codes and standards. ` A full seismic analysis has been performed in accordance with ASCE 7-10. However, the results due to seismic analysis are not controlling; the analysis results due to wind loading are controlling for the overall capacity. Based on our analysis results, the tower and foundation ARE within capacity to support the loads under the current loading scenario. Table 2 – Tower Section Capacity Section No. Elevation ft Component Type Size % Capacity Pass Fail L1 91.5 - 45 Pole TP30.83x22x0.1875 30.6 Pass L2 45 - 0 Pole TP39.0002x29.5055x0.25 39.4 Pass Summary Bolt Checks 39.4 Pass RATING = 39.4 Pass Table 3 – Capacity of Additional Components Notes Component Elevation (ft) % Capacity Pass / Fail 1 Anchor Rods 0 30.2 Pass 1 Base Plate 39.2 Pass 1, 2 Foundation Option #1 – Pad & Pier Soil 0 34.4 Pass 1, 2 Foundation Option #1 – Pad & Pier Structural 28.3 Pass 1, 2 Foundation Option #2 – Drilled Pier Soil 0 15.8 Pass 1, 2 Foundation Option #2 – Drilled Pier Structural 28.3 Pass Structure Rating (max from all components) = 39.4% Notes: 1) See additional documentation in “Additional Calculations” for calculations supporting the % capacity consumed. 2) It is unknown whether the foundation installed is a pad & pier or driller pier; both designs were analyzed & determined to be sufficient. 3) This analysis has been performed according to the controlling load case of existing, reserved and proposed loading. 8.0 RECOMMENDATIONS 1) All assumptions made in this analysis should be carefully reviewed. Morrison Hershfield should be contacted for any discrepancies so that a full assessment may be made to validate the results of this analysis. ATTACHMENTS: Tower Profile, Program Output, Coax Sketch, Additional Calculations and RF Data Sheet Morrison Hershfield TOWER PROFILE Consulting Engineers Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Job: TMB-185R2 / 2021192 Project: SE04653A / LAKOTA PARK Client: Ryka Consulting Drawn by: CKK App'd: Code: TIA-222-G Date: 09/22/20 Scale: NTS Path: C:\Users\ckatari\Desktop\TMB-185 - SE04653A - Lakota Park\TMB-185R2 SA\Analysis\TMB-185R2.eri Dwg No. E-1 91.5 ft 45.0 ft 0.0 ft REACTIONS - 85 mph WIND TORQUE 1 kip-ft 9 K SHEAR 608 kip-ft MOMENT 14 K AXIAL 30 mph WIND - 0.2500 in ICE TORQUE 0 kip-ft 1 K SHEAR 70 kip-ft MOMENT 18 K AXIAL ARE FACTORED ALL REACTIONS Section12 Length (ft)46.5050.00 Number of Sides1818 Thickness (in)0.18750.2500 Socket Length (ft)5.00 Top Dia (in)22.000029.5055 Bot Dia (in)30.830039.0002 GradeA572-65 Weight (K)2.54.67.1 Lighting Rod 5/8" x 4' on 4' Pole (Per Photos) 95.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 (2) 6' x 2" Mount Pipe (E-Per Photos) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 Standoff Mount (E) 81 Standoff Mount (E) 81 Standoff Mount (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 Standoff Mount (E) 78 Standoff Mount (E) 78 Standoff Mount (E) 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 Standoff Mount (E) 75 Standoff Mount (E) 75 Standoff Mount (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75DESIGNED APPURTENANCE LOADING TYPE TYPEELEVATION ELEVATION Lighting Rod 5/8" x 4' on 4' Pole (Per Photos) 95.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 (2) 6' x 2" Mount Pipe (E-Per Photos) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 Standoff Mount (E) 81 Standoff Mount (E) 81 Standoff Mount (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 Standoff Mount (E) 78 Standoff Mount (E) 78 Standoff Mount (E) 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 Standoff Mount (E) 75 Standoff Mount (E) 75 Standoff Mount (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in King County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 0.25 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING: 39.4% Morrison Hershfield PROGRAM OUTPUT ttnnxxTToowweerr Job TMB-185R2 / 2021192 Page 1 of 5 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Project SE04653A / LAKOTA PARK Date 19:04:33 09/22/20 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Client Ryka Consulting Designed by CKK Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in King County, Washington. Basic wind speed of 85 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 0.2500 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression √ Use Code Stress Ratios Use Clear Spans For KL/r All Leg Panels Have Same Allowable √ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque Always Use Max Kz √ Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-G Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles Secondary Horizontal Braces Leg Sort Capacity Reports By Component √ Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 91.50-45.00 46.50 5.00 18 22.0000 30.8300 0.1875 0.7500 A572-65 (65 ksi) L2 45.00-0.00 50.00 18 29.5055 39.0002 0.2500 1.0000 A572-65 (65 ksi) ttnnxxTToowweerr Job TMB-185R2 / 2021192 Page 2 of 5 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Project SE04653A / LAKOTA PARK Date 19:04:33 09/22/20 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Client Ryka Consulting Designed by CKK Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Exclude From Torque Calculation Component Type Placement ft Total Number Number Per Row Start/End Position Width or Diameter in Perimeter in Weight plf *** Safety Line 3/8 (Tower) B No Surface Ar (CaAa) 91.50 - 11.00 1 1 0.000 0.000 0.3750 0.22 Step Pegs (Tower) B No Surface Ar (CaAa) 91.50 - 11.00 1 1 -0.050 0.050 0.7050 1.80 *** Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number CAAA ft2/ft Weight plf *** 7/8'' (P) A No No Inside Pole 87.50 - 8.00 6 No Ice 1/2'' Ice 0.00 0.00 0.33 0.33 HCS 2.0 Pendant (P) A No No Inside Pole 87.50 - 8.00 2 No Ice 1/2'' Ice 0.00 0.00 1.71 1.71 *** 3/4'' DC (E) C No No Inside Pole 81.00 - 8.00 1 No Ice 1/2'' Ice 0.00 0.00 0.88 0.88 *** Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K *** Lighting Rod 5/8'' x 4' on 4' Pole (Per Photos) B None 0.0000 95.50 No Ice 1/2'' Ice 1.46 2.13 1.46 2.13 0.07 0.09 ***T-Mobile*** 9' x 2'' Pipe Mount (E-Per Photos) C From Leg 4.00 -6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.14 3.07 2.14 3.07 0.07 0.08 9' x 2'' Pipe Mount (E-Per Photos) B From Leg 4.00 -6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.14 3.07 2.14 3.07 0.07 0.08 9' x 2'' Pipe Mount (E-Per Photos) C From Leg 4.00 -6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.14 3.07 2.14 3.07 0.07 0.08 (2) 6' x 2'' Mount Pipe (E-Per Photos) A From Leg 2.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 1.43 1.92 1.43 1.92 0.02 0.03 12' T-Arm (E) A From Leg 2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.28 9.52 3.02 4.20 0.26 0.33 ttnnxxTToowweerr Job TMB-185R2 / 2021192 Page 3 of 5 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Project SE04653A / LAKOTA PARK Date 19:04:33 09/22/20 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Client Ryka Consulting Designed by CKK Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 12' T-Arm (E) B From Leg 2.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.28 9.52 3.02 4.20 0.26 0.33 12' T-Arm (E) C From Leg 2.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.28 9.52 3.02 4.20 0.26 0.33 *** HBXX-6517DS-A2M w/ Mount Pipe (p) A From Leg 4.00 2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.97 8.73 5.99 6.72 0.08 0.14 HBXX-6517DS-A2M w/ Mount Pipe (p) B From Leg 4.00 2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.97 8.73 5.99 6.72 0.08 0.14 HBXX-6517DS-A2M w/ Mount Pipe (p) C From Leg 4.00 2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 7.97 8.73 5.99 6.72 0.08 0.14 FFVV-65C-R3-V1 w/ Mount Pipe (P) A From Leg 4.00 6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 12.97 13.62 6.20 6.77 0.18 0.32 FFVV-65C-R3-V1 w/ Mount Pipe (P) B From Leg 4.00 6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 12.97 13.62 6.20 6.77 0.18 0.32 FFVV-65C-R3-V1 w/ Mount Pipe (P) C From Leg 4.00 6.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 12.97 13.62 6.20 6.77 0.18 0.32 AEHC w/ Mount Pipe (P) A From Leg 4.00 -2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 6.96 7.34 3.45 3.93 0.11 0.17 AEHC w/ Mount Pipe (P) B From Leg 4.00 -2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 6.96 7.34 3.45 3.93 0.11 0.17 AEHC w/ Mount Pipe (P) C From Leg 4.00 -2.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 6.96 7.34 3.45 3.93 0.11 0.17 AHFIG (P) A From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 3.08 3.31 1.40 1.59 0.08 0.10 AHFIG (P) B From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 3.08 3.31 1.40 1.59 0.08 0.10 AHFIG (P) C From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 3.08 3.31 1.40 1.59 0.08 0.10 AHLOA (P) A From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.23 2.42 1.39 1.55 0.08 0.10 AHLOA (P) B From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.23 2.42 1.39 1.55 0.08 0.10 AHLOA (P) C From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 2.23 2.42 1.39 1.55 0.08 0.10 TMAT1921B68-21-43 (P) A From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 0.66 0.76 0.32 0.40 0.02 0.02 TMAT1921B68-21-43 B From Leg 4.00 0.0000 87.50 No Ice 0.66 0.32 0.02 ttnnxxTToowweerr Job TMB-185R2 / 2021192 Page 4 of 5 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Project SE04653A / LAKOTA PARK Date 19:04:33 09/22/20 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Client Ryka Consulting Designed by CKK Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K (P) 0.00 0.00 1/2'' Ice 0.76 0.40 0.02 TMAT1921B68-21-43 (P) C From Leg 4.00 0.00 0.00 0.0000 87.50 No Ice 1/2'' Ice 0.66 0.76 0.32 0.40 0.02 0.02 *** Standoff Mount (E) A From Leg 1.50 0.00 0.00 0.0000 81.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) B From Leg 1.50 0.00 0.00 0.0000 81.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) C From Leg 1.50 0.00 0.00 0.0000 81.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 *** Standoff Mount (E) A From Leg 1.50 0.00 0.00 0.0000 78.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) B From Leg 1.50 0.00 0.00 0.0000 78.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) C From Leg 1.50 0.00 0.00 0.0000 78.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 *** Standoff Mount (E) A From Leg 1.50 0.00 0.00 0.0000 75.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) B From Leg 1.50 0.00 0.00 0.0000 75.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 Standoff Mount (E) C From Leg 1.50 0.00 0.00 0.0000 75.00 No Ice 1/2'' Ice 1.51 1.82 0.67 0.93 0.10 0.14 *** Dishes Description Face or Leg Dish Type Offset Type Offsets: Horz Lateral Vert ft Azimuth Adjustment ° 3 dB Beam Width ° Elevation ft Outside Diameter ft Aperture Area ft2 Weight K *** 24'' Stadium Light (E) A Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 81.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) B Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 81.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) C Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.0000 81.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 ttnnxxTToowweerr Job TMB-185R2 / 2021192 Page 5 of 5 Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Project SE04653A / LAKOTA PARK Date 19:04:33 09/22/20 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Client Ryka Consulting Designed by CKK Description Face or Leg Dish Type Offset Type Offsets: Horz Lateral Vert ft Azimuth Adjustment ° 3 dB Beam Width ° Elevation ft Outside Diameter ft Aperture Area ft2 Weight K 0.00 *** 24'' Stadium Light (E) A Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 78.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) B Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 78.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) C Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 78.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 *** 24'' Stadium Light (E) A Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 75.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) B Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 75.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 24'' Stadium Light (E) C Paraboloid w/Shroud (HP) From Leg 3.00 0.00 0.00 0.0000 75.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.03 0.04 *** Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 91.5 - 45 Pole TP30.83x22x0.1875 1 -7.47 1120.94 30.6 Pass L2 45 - 0 Pole TP39.0002x29.5055x0.25 2 -13.90 1969.73 39.4 Pass Summary Pole (L2) 39.4 Pass RATING = 39.4 Pass Morrison Hershfield COAX SKETCH Consulting Engineers Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Job: TMB-185R2 / 2021192 Project: SE04653A / LAKOTA PARK Client: Ryka Consulting Drawn by: CKK App'd: Code: TIA-222-G Date: 09/22/20 Scale: NTS Path: C:\Users\ckatari\Desktop\TMB-185 - SE04653A - Lakota Park\TMB-185R2 SA\Analysis\TMB-185R2.eri Dwg No. E-7 Feed Line Plan 45' Section @ 45' (6) 7/8" (P) (2) HCS 2.0 Pendant (P) 3/4" DC (E) Morrison Hershfield ADDITIONAL CALCULATIONS Monopole Base Plate Connection TMB-185R2 / 2021192 #VALUE! Anchor Rod Data Anchor Rod Summary (units of kips, kip-in) (16) 1-1/2" ø bolts (F1554-105 N; Fy=105 ksi, Fu=125 ksi) on 45" BC Pu_c = 41.38 φPn_t = 141 Stress Rating Vu = 0.58 φVn = n/a 30.2% Base Plate Data Mu = n/a φMn = n/a Pass 51" OD x 1.5" Plate (A572-50; Fy=50 ksi, Fu=65 ksi) Base Plate Summary Stiffener Data Max Stress (ksi):17.64 (Flexural) N/A Allowable Stress (ksi):45 Stress Rating:39.2%Pass Pole Data 39.0002" x 0.25" 18-sided pole (A572-65; Fy=65 ksi, Fu=80 ksi) Analysis ResultsConnection Properties Iar (in) 0 Eta Factor, η 0.5 Moment (kip-ft) 607.91 Axial Force (kips) 13.90 Shear Force (kips) 9.31 Moment (kip-ft) Axial Force (kips) Shear Force (kips) 0.00 Project No. Applied Loads Site Name LAKOTA PARK Site ID # SE04653A Analysis Considerations Site Info TIA-222 Revision G Grout Considered:No 13.90 9.31 Adjusted Pole Reactions Analysis Date: 9/22/2020 TMB-185R2 / 2021192 Tower Type: 13.91 kips Capacity Demand Rating Check 9.3 kips 328.69 0.00 0.0% Pass 151.41 9.30 6.1% Pass 4.50 1.55 34.4% Pass 607.91 ft-kips 2288.53 675.34 29.5% Pass 91.5 ft 2308.44 654.41 28.3% Pass ft 691.79 0.00 0.0% Pass 3 in 15121.68 35.29 0.2% Pass in 1405.18 209.31 14.9% Pass 399.59 48.09 12.0% Pass 0.190 0.022 11.7% Pass Circular 1768.28 0.00 0.0% Pass 5.5 ft 0.190 0.000 0.0% Pass 0.5 ft 1768.28 0.00 0.0% Pass 8 23 4 Soil Rating:34.4% 14 Structural Rating:28.3% Tie 3 in 6.5 ft 18 ft 2 ft 8 21 3 in 60 ksi 4 ksi 150 pcf 120 pcf 6.000 ksf <--Toggle between Gross and Net 0.000 ksf 35 degrees 17 0.38 2.75 ft No N/A ft D Top & Bot. Pad Rein. Different?: Foundation Bearing on Rock? SPT Blow Count, Nblows: Base Friction, µ: Pier Diameter, dpier: Ext. Above Grade, E: Pier Rebar Size, Sc: Total Soil Unit Weight, γ: Pier Rebar Quantity, mc: Concrete Compressive Strength, F'c: Pier Tie/Spiral Quantity, mt: Pier Reinforcement Type: Pier Clear Cover, ccpier: Pad Properties Pier Tie/Spiral Size, St: Neglected Depth, N: Uplift Shear, Vu_uplift: Pier Shape: Tower Height, H: Base Face Width, BW: Cohesion, Cu: Ultimate Gross Bearing, Qult: Pier Flexure (Comp.) (kip*ft) Lateral (Sliding) (kips) Bearing Pressure (ksf) Uplift (kips) Foundation Analysis Checks Pier and Pad Foundation Project # : Site Name: Compression, Pcomp: TIA-222 Revision: Site ID: Superstructure Analysis Reactions G Monopole LAKOTA PARK SE04653A Block Foundation?: Pad Shear - 2-way (Comp) (ksi) Pier Flexure (Tension) (kip*ft) Overturning (kip*ft) Pad Flexure (kip*ft) Pad Shear - 1-way (kips) Pier Compression (kip) Flexural 2-way (Tension) (kip*ft) Pad Shear - 2-way (Uplift) (ksi) Pier Properties BP Dist. Above Fdn, bpdist: Bolt Circle / Bearing Plate Width, BC: Flexural 2-way (Comp) (kip*ft) Uplift, Puplift: Base Shear, Vu_comp: Seismic Design Category: Groundwater Depth, gw: Rebar Grade, Fy: Dry Concrete Density, δc: Depth, D: Pad Width, W: Pad Thickness, T: Pad Rebar Size (Bottom), Sp: Pad Rebar Quantity (Bottom), mp: Pad Clear Cover, ccpad: Material Properties Soil Properties Friction Angle, : Moment, Mu: TIA-222 Revison:Check Pier Capacity only at location of Max Moment?NoTower Type:Soil Lateral CheckCompression UpliftComp. Uplift5.88 -607.918.44 -13.91661.71 -9.315.8% -Soil Vertical CheckCompression Uplift221.28 -4 ksi437.45 -60 ksi87.67 -60 ksi658.73 -101.58 -15.4% -20 ftReinforced Concrete FlexureCompression Uplift0.5 ft5.68 -661.61 -2336.03 -5.5 ft28.3% -2723Reinforced Concrete ShearCompression Uplift815.47 -3 in104.20 -4428.75 -12 in24.3% -inN/A# of Layers 3121FALSE1 0 2.75 2.75 120 150 0 0 0.000 0.0000.00 0.00FALSE2 2.75 10 7.25 120 150 0 35 0.000 0.0000.70 0.70FALSE3 10 20 10 120 150 0 42 0.000 0.0001.20 1.2024.5528.3%Structural Foundation RatingTotal Capacity (kips)Tie Yield Strength, Fyt:Tie SpacingCritical Depth (ft from TOC)Critical Depth (ft from TOC)15.8%Soil Interaction RatingDepthExt. Above GradeCritical Moment (kip-ft)Critical Moment CapacityRatingCohesionlessCohesionlessUltimate Skin Friction Uplift Override (ksf)Critical Shear CapacityRatingCohesionlessAnalysis ResultsDrilled Pier FoundationMonopoleApplied LoadsMaterial PropertiesPier Design DataGTMB-185R2 / 2021192LAKOTA PARKSE04653AMoment (kip-ft)Axial Force (kips)Shear Force (kips)Concrete Strength, f'c:Dv=0 (ft from TOC)Soil Safety FactorMax Moment (kip-ft)RatingSkin Friction (kips)Weight of Concrete (kips)RatingCalculated Ultimate Skin Friction Uplift (ksf)Calculated Ultimate Skin Friction Comp (ksf)LayerTop (ft)Bottom (ft)Thickness (ft)Ultimate Skin Friction Comp Override (ksf)Groundwater DepthSoil ProfileSoil TypeSPT Blow CountUlt. Gross Bearing Capacity (ksf)γsoil (pcf)γconcrete (pcf)Cohesion (ksf)Angle of Friction (degrees)From 0.5' above grade to 20' below gradeRebar SizeClear Cover to TiesTie SizeRebar QuantityRebar Cage DiameterRebar Strength, Fy:End Bearing (kips)Axial (kips)Pier Section 1Pier DiameterRebar QuantityRebar SizeCritical Shear (kip)Rebar & Pier OptionsEmbedded Pole InputsBelled Pier Inputs Decimal Degrees Deg Min Sec ###Lat: 47.320444 + 47 19 13.60 ###Long: -122.360333 - 122 21 37.20 ###Seismic Design Code: ASCE 7-10 ###Site Soil: D Stiff Soil (Default) Risk Category: II ###USGS Seismic Reference SS:1.3110 g ###S1:0.5040 g TL:6 s ###1 Importance Factor, Ie:1 Acceleration-based site coefficient, Fa:1.0000 Velocity-based site coefficient, Fv:1.5000 Design spectral response acceleration short period, SDS:0.8740 g Design spectral response acceleration 1 s period, SD1:0.5040 g Seismic Design Category Based on SDS:D Seismic Design Category Based on SD1:D Seismic Design Category Based on S1:N/A Controlling Seismic Design Category: D Location Code and Site Parameters Seismic Design Category Determination CCISeismic 3.3.2 Page 1 Analysis Date: 9/22/2020 Tower Type:Tapered Monopole Height, h:91.5 ft ###Effective Seismic Weight, W:11.59 kips Response Modification Factor, R: 1.5 ###1.792369008 Discrete Appurtenance Weight in Top 1/3 of Structure, Wu:3.87368 kips WL:7.716524305 kips E:29000.0 ksi g: 386.088 in/s2 Average Moment of Inertia, Iavg:2757.930262 in4 Fa:0.557920827 hz Approximate Fundamental Period Monopole, Ta:1.7924 s Seismic Response Coefficient, Cs 0.5827 12.8-2 Seismic Response Coefficient Max 1, Csmax 0.1875 12.8-3 Seismic Response Coefficient Max 2, Csmax N/A 12.8-4 Seismic Response Coefficient Min 1, Csmin 0.0385 15.4-1 Seismic Response Coefficient Min 2, Csmin N/A 15.4-2 Controlling Seismic Response Coefficient, Csc 0.1875 Seismic Base Shear, V 2.173 kips 12.8-1 Period Related Exponent, k: 1.646 12.8-12 Sum of wihi k 9809.20 12.8-12 Tower Details Seismic Base Shear Vertical Distribution Factors Page 2 Analysis Date: 9/22/2020 Section Number Length Top Height Mid Height, hx Section Weight, wx wxhx k Cvx Fxh Fxv 1 - 1 6.50 91.50 88.25 0.2952 471.16 0.0480 0.1044 0.0516 1 - 2 10.00 85.00 80.00 0.4859 659.79 0.0673 0.1461 0.0849 1 - 3 10.00 75.00 70.00 0.5244 571.50 0.0583 0.1266 0.0917 1 - 4 10.00 65.00 60.00 0.5628 475.93 0.0485 0.1054 0.0984 1 - 5 10.00 55.00 50.00 0.6013 376.62 0.0384 0.0834 0.1051 2 - 1 10.00 50.00 45.00 0.8155 429.47 0.0438 0.0951 0.1426 2 - 2 10.00 40.00 35.00 0.8668 301.82 0.0308 0.0669 0.1515 2 - 3 10.00 30.00 25.00 0.9181 183.72 0.0187 0.0407 0.1605 2 - 4 10.00 20.00 15.00 0.9694 83.67 0.0085 0.0185 0.1694 2 - 5 10.00 10.00 5.00 1.0206 14.44 0.0015 0.0032 0.1784 Sum 7.0601 3568.11 Tower Section Loads Page 3 Analysis Date: 9/22/2020 Name hx wx wxhx k Cvx Fxh Fxv tower mounts Lighting Rod 5/8" x 4' on 4' Pole 95.50 0.0700 127.22 0.0130 0.0282 0.0122 tower mounts 9' x 2" Pipe Mount 87.50 0.0700 110.15 0.0112 0.0244 0.0122 tower mounts 9' x 2" Pipe Mount 87.50 0.0700 110.15 0.0112 0.0244 0.0122 tower mounts 9' x 2" Pipe Mount 87.50 0.0700 110.15 0.0112 0.0244 0.0122 (2) tower mounts 6' x 2" Mount Pipe 87.50 0.0400 62.95 0.0064 0.0139 0.0070 12' T-Arm 87.50 0.2581 406.15 0.0414 0.0900 0.0451 12' T-Arm 87.50 0.2581 406.15 0.0414 0.0900 0.0451 12' T-Arm 87.50 0.2581 406.15 0.0414 0.0900 0.0451 andrew HBXX-6517DS-A2M w/ Mount Pipe 87.50 0.0758 119.30 0.0122 0.0264 0.0133 andrew HBXX-6517DS-A2M w/ Mount Pipe 87.50 0.0758 119.30 0.0122 0.0264 0.0133 andrew HBXX-6517DS-A2M w/ Mount Pipe 87.50 0.0758 119.30 0.0122 0.0264 0.0133 commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.50 0.1827 287.42 0.0293 0.0637 0.0319 commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.50 0.1827 287.42 0.0293 0.0637 0.0319 commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.50 0.1827 287.42 0.0293 0.0637 0.0319 nokia AEHC w/ Mount Pipe 87.50 0.1100 173.10 0.0176 0.0383 0.0192 nokia AEHC w/ Mount Pipe 87.50 0.1100 173.10 0.0176 0.0383 0.0192 nokia AEHC w/ Mount Pipe 87.50 0.1100 173.10 0.0176 0.0383 0.0192 nokia AHFIG 87.50 0.0800 125.89 0.0128 0.0279 0.0140 nokia AHFIG 87.50 0.0800 125.89 0.0128 0.0279 0.0140 nokia AHFIG 87.50 0.0800 125.89 0.0128 0.0279 0.0140 nokia AHLOA 87.50 0.0800 125.89 0.0128 0.0279 0.0140 nokia AHLOA 87.50 0.0800 125.89 0.0128 0.0279 0.0140 nokia AHLOA 87.50 0.0800 125.89 0.0128 0.0279 0.0140 commscope TMAT1921B68-21-43 87.50 0.0200 31.47 0.0032 0.0070 0.0035 commscope TMAT1921B68-21-43 87.50 0.0200 31.47 0.0032 0.0070 0.0035 commscope TMAT1921B68-21-43 87.50 0.0200 31.47 0.0032 0.0070 0.0035 Standoff Mount 81.00 0.0960 133.04 0.0136 0.0295 0.0168 Standoff Mount 81.00 0.0960 133.04 0.0136 0.0295 0.0168 Standoff Mount 81.00 0.0960 133.04 0.0136 0.0295 0.0168 Standoff Mount 78.00 0.0960 125.03 0.0127 0.0277 0.0168 Standoff Mount 78.00 0.0960 125.03 0.0127 0.0277 0.0168 Standoff Mount 78.00 0.0960 125.03 0.0127 0.0277 0.0168 Standoff Mount 75.00 0.0960 117.21 0.0119 0.0260 0.0168 Standoff Mount 75.00 0.0960 117.21 0.0119 0.0260 0.0168 Standoff Mount 75.00 0.0960 117.21 0.0119 0.0260 0.0168 24" Stadium Light 81.00 0.0300 41.58 0.0042 0.0092 0.0052 24" Stadium Light 81.00 0.0300 41.58 0.0042 0.0092 0.0052 24" Stadium Light 81.00 0.0300 41.58 0.0042 0.0092 0.0052 24" Stadium Light 78.00 0.0300 39.07 0.0040 0.0087 0.0052 24" Stadium Light 78.00 0.0300 39.07 0.0040 0.0087 0.0052 24" Stadium Light 78.00 0.0300 39.07 0.0040 0.0087 0.0052 24" Stadium Light 75.00 0.0300 36.63 0.0037 0.0081 0.0052 24" Stadium Light 75.00 0.0300 36.63 0.0037 0.0081 0.0052 24" Stadium Light 75.00 0.0300 36.63 0.0037 0.0081 0.0052 Sum 3.8737 5805.99 Discrete Loads Page 4 Analysis Date: 9/22/2020 Name Start Height End Height hx wx wxhx k Cvx Fxh Fxv miscl Safety Line 3/8 From 11 to 91.5 81.50 91.50 86.50 0.0022 3.40 0.0003 0.0008 0.0004 miscl Safety Line 3/8 From 11 to 91.5 71.50 81.50 76.50 0.0022 2.78 0.0003 0.0006 0.0004 miscl Safety Line 3/8 From 11 to 91.5 61.50 71.50 66.50 0.0022 2.20 0.0002 0.0005 0.0004 miscl Safety Line 3/8 From 11 to 91.5 51.50 61.50 56.50 0.0022 1.69 0.0002 0.0004 0.0004 miscl Safety Line 3/8 From 11 to 91.5 41.50 51.50 46.50 0.0022 1.22 0.0001 0.0003 0.0004 miscl Safety Line 3/8 From 11 to 91.5 31.50 41.50 36.50 0.0022 0.82 0.0001 0.0002 0.0004 miscl Safety Line 3/8 From 11 to 91.5 21.50 31.50 26.50 0.0022 0.48 0.0000 0.0001 0.0004 miscl Safety Line 3/8 From 11 to 91.5 11.50 21.50 16.50 0.0022 0.22 0.0000 0.0000 0.0004 miscl Safety Line 3/8 From 11 to 91.5 11.00 11.50 11.25 0.0001 0.01 0.0000 0.0000 0.0000 Step Pegs From 11 to 91.5 81.50 91.50 86.50 0.0180 27.86 0.0028 0.0062 0.0032 Step Pegs From 11 to 91.5 71.50 81.50 76.50 0.0180 22.76 0.0023 0.0050 0.0032 Step Pegs From 11 to 91.5 61.50 71.50 66.50 0.0180 18.07 0.0018 0.0040 0.0032 Step Pegs From 11 to 91.5 51.50 61.50 56.50 0.0180 13.82 0.0014 0.0031 0.0032 Step Pegs From 11 to 91.5 41.50 51.50 46.50 0.0180 10.03 0.0010 0.0022 0.0032 Step Pegs From 11 to 91.5 31.50 41.50 36.50 0.0180 6.73 0.0007 0.0015 0.0032 Step Pegs From 11 to 91.5 21.50 31.50 26.50 0.0180 3.97 0.0004 0.0009 0.0032 Step Pegs From 11 to 91.5 11.50 21.50 16.50 0.0180 1.82 0.0002 0.0004 0.0032 Step Pegs From 11 to 91.5 11.00 11.50 11.25 0.0009 0.05 0.0000 0.0000 0.0002 (6) 7/8" From 8 to 87.5 81.50 87.50 84.50 0.0119 17.65 0.0018 0.0039 0.0021 (6) 7/8" From 8 to 87.5 71.50 81.50 76.50 0.0198 24.98 0.0025 0.0055 0.0035 (6) 7/8" From 8 to 87.5 61.50 71.50 66.50 0.0198 19.83 0.0020 0.0044 0.0035 (6) 7/8" From 8 to 87.5 51.50 61.50 56.50 0.0198 15.17 0.0015 0.0034 0.0035 (6) 7/8" From 8 to 87.5 41.50 51.50 46.50 0.0198 11.01 0.0011 0.0024 0.0035 (6) 7/8" From 8 to 87.5 31.50 41.50 36.50 0.0198 7.39 0.0008 0.0016 0.0035 (6) 7/8" From 8 to 87.5 21.50 31.50 26.50 0.0198 4.36 0.0004 0.0010 0.0035 (6) 7/8" From 8 to 87.5 11.50 21.50 16.50 0.0198 2.00 0.0002 0.0004 0.0035 (6) 7/8" From 8 to 87.5 8.00 11.50 9.75 0.0069 0.29 0.0000 0.0001 0.0012 (2) HCS 2.0 Pendant From 8 to 87.5 81.50 87.50 84.50 0.0205 30.49 0.0031 0.0068 0.0036 (2) HCS 2.0 Pendant From 8 to 87.5 71.50 81.50 76.50 0.0342 43.14 0.0044 0.0096 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 61.50 71.50 66.50 0.0342 34.26 0.0035 0.0076 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 51.50 61.50 56.50 0.0342 26.20 0.0027 0.0058 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 41.50 51.50 46.50 0.0342 19.01 0.0019 0.0042 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 31.50 41.50 36.50 0.0342 12.76 0.0013 0.0028 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 21.50 31.50 26.50 0.0342 7.53 0.0008 0.0017 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 11.50 21.50 16.50 0.0342 3.45 0.0004 0.0008 0.0060 (2) HCS 2.0 Pendant From 8 to 87.5 8.00 11.50 9.75 0.0120 0.51 0.0001 0.0001 0.0021 3/4" DC From 8 to 81 71.50 81.00 76.25 0.0084 10.49 0.0011 0.0023 0.0015 3/4" DC From 8 to 81 61.50 71.50 66.50 0.0088 8.81 0.0009 0.0020 0.0015 3/4" DC From 8 to 81 51.50 61.50 56.50 0.0088 6.74 0.0007 0.0015 0.0015 3/4" DC From 8 to 81 41.50 51.50 46.50 0.0088 4.89 0.0005 0.0011 0.0015 3/4" DC From 8 to 81 31.50 41.50 36.50 0.0088 3.28 0.0003 0.0007 0.0015 3/4" DC From 8 to 81 21.50 31.50 26.50 0.0088 1.94 0.0002 0.0004 0.0015 3/4" DC From 8 to 81 11.50 21.50 16.50 0.0088 0.89 0.0001 0.0002 0.0015 3/4" DC From 8 to 81 8.00 11.50 9.75 0.0031 0.13 0.0000 0.0000 0.0005 Sum 0.6565 435.11 Linear Loads Page 5 Analysis Date: 9/22/2020 Consulting Engineers Morrison Hershfield 1455 Lincoln Parkway, Suite 500 Atlanta, GA 30346 Phone: (770) 379-8500 FAX: (770) 379-8501 Job: TMB-185R2 / 2021192 (Seismic) Project: SE04653A / LAKOTA PARK Client: Ryka Consulting Drawn by: CKK App'd: Code: TIA-222-G Date: 09/22/20 Scale: NTS Path: C:\Users\ckatari\Desktop\TMB-185 - SE04653A - Lakota Park\TMB-185R2 SA\Analysis\TMB-185R2 CCISeismic 3.3.2 Wind And Seismic Analysis.eri Dwg No. E-1 91.5 ft 45.0 ft 0.0 ft REACTIONS - 85 mph WIND TORQUE 1 kip-ft 9 K SHEAR 608 kip-ft MOMENT 14 K AXIAL 30 mph WIND - 0.2500 in ICE TORQUE 0 kip-ft 1 K SHEAR 70 kip-ft MOMENT 18 K AXIAL SEISMIC TORQUE 0 kip-ft 2 K SHEAR 169 kip-ft MOMENT 16 K AXIAL ARE FACTORED ALL REACTIONS Section12 Length (ft)46.5050.00 Number of Sides1818 Thickness (in)0.18750.2500 Socket Length (ft)5.00 Top Dia (in)22.000029.5055 Bot Dia (in)30.830039.0002 GradeA572-65 Weight (K)2.54.67.1 Lighting Rod 5/8" x 4' on 4' Pole (Per Photos) 95.5 CCISeismic tower mounts Lighting Rod 5/8" x 4' on 4' Pole 95.5 CCISeismic Tower Section 1 - 1 88.25 9' x 2" Pipe Mount (E-Per Photos) 87.5 (2) 6' x 2" Mount Pipe (E-Per Photos) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic (2) tower mounts 6' x 2" Mount Pipe 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (81.5ft to91.5ft) 86.5 CCISeismic Step Pegs From 11 to 91.5 (81.5ft to91.5ft) 86.5 CCISeismic (6) 7/8" From 8 to 87.5 (81.5ft to87.5ft) 84.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (81.5ft to87.5ft) 84.5 24" Stadium Light (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 Standoff Mount (E) 81 CCISeismic Standoff Mount 81 CCISeismic Standoff Mount 81 CCISeismic Standoff Mount 81 CCISeismic 24" Stadium Light 81 CCISeismic 24" Stadium Light 81 CCISeismic 24" Stadium Light 81 Standoff Mount (E) 81 Standoff Mount (E) 81 CCISeismic Tower Section 1 - 2 80 Standoff Mount (E) 78 Standoff Mount (E) 78 CCISeismic Standoff Mount 78 CCISeismic Standoff Mount 78 CCISeismic Standoff Mount 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 CCISeismic 24" Stadium Light 78 CCISeismic 24" Stadium Light 78 CCISeismic 24" Stadium Light 78 24" Stadium Light (E) 78 Standoff Mount (E) 78 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (71.5ft to81.5ft) 76.5 CCISeismic Step Pegs From 11 to 91.5 (71.5ft to81.5ft) 76.5 CCISeismic (6) 7/8" From 8 to 87.5 (71.5ft to81.5ft) 76.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (71.5ft to81.5ft) 76.5 CCISeismic 3/4" DC From 8 to 81 (71.5ft to81ft) 76.25 CCISeismic Standoff Mount 75 CCISeismic Standoff Mount 75 Standoff Mount (E) 75 CCISeismic 24" Stadium Light 75 CCISeismic 24" Stadium Light 75 CCISeismic 24" Stadium Light 75 Standoff Mount (E) 75 Standoff Mount (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 CCISeismic Standoff Mount 75 CCISeismic Tower Section 1 - 3 70 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (61.5ft to71.5ft) 66.5 CCISeismic Step Pegs From 11 to 91.5 (61.5ft to71.5ft) 66.5 CCISeismic (6) 7/8" From 8 to 87.5 (61.5ft to71.5ft) 66.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (61.5ft to71.5ft) 66.5 CCISeismic 3/4" DC From 8 to 81 (61.5ft to71.5ft) 66.5 CCISeismic Tower Section 1 - 4 60 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (51.5ft to61.5ft) 56.5 CCISeismic Step Pegs From 11 to 91.5 (51.5ft to61.5ft) 56.5 CCISeismic (6) 7/8" From 8 to 87.5 (51.5ft to61.5ft) 56.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (51.5ft to61.5ft) 56.5 CCISeismic 3/4" DC From 8 to 81 (51.5ft to61.5ft) 56.5 CCISeismic Tower Section 1 - 5 50 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (41.5ft to51.5ft) 46.5 CCISeismic Step Pegs From 11 to 91.5 (41.5ft to51.5ft) 46.5 CCISeismic (6) 7/8" From 8 to 87.5 (41.5ft to51.5ft) 46.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (41.5ft to51.5ft) 46.5 CCISeismic 3/4" DC From 8 to 81 (41.5ft to51.5ft) 46.5 CCISeismic Tower Section 2 - 1 45 CCISeismic Step Pegs From 11 to 91.5 (31.5ft to41.5ft) 36.5 CCISeismic (6) 7/8" From 8 to 87.5 (31.5ft to41.5ft) 36.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (31.5ft to41.5ft) 36.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (31.5ft to41.5ft) 36.5 CCISeismic 3/4" DC From 8 to 81 (31.5ft to41.5ft) 36.5 CCISeismic Tower Section 2 - 2 35 CCISeismic Step Pegs From 11 to 91.5 (21.5ft to31.5ft) 26.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (21.5ft to31.5ft) 26.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (21.5ft to31.5ft) 26.5 CCISeismic (6) 7/8" From 8 to 87.5 (21.5ft to31.5ft) 26.5 CCISeismic 3/4" DC From 8 to 81 (21.5ft to31.5ft) 26.5 CCISeismic Tower Section 2 - 3 25 CCISeismic (6) 7/8" From 8 to 87.5 (11.5ft to21.5ft) 16.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (11.5ft to21.5ft) 16.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (11.5ft to21.5ft) 16.5 CCISeismic Step Pegs From 11 to 91.5 (11.5ft to21.5ft) 16.5 CCISeismic 3/4" DC From 8 to 81 (11.5ft to21.5ft) 16.5 CCISeismic Tower Section 2 - 4 15 CCISeismic Step Pegs From 11 to 91.5 (11ft to11.5ft) 11.25 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (11ft to11.5ft) 11.25 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (8ft to11.5ft) 9.75 CCISeismic (6) 7/8" From 8 to 87.5 (8ft to11.5ft) 9.75 CCISeismic 3/4" DC From 8 to 81 (8ft to11.5ft) 9.75 CCISeismic Tower Section 2 - 5 5DESIGNED APPURTENANCE LOADING TYPE TYPEELEVATION ELEVATION Lighting Rod 5/8" x 4' on 4' Pole (Per Photos) 95.5 CCISeismic tower mounts Lighting Rod 5/8" x 4' on 4' Pole 95.5 CCISeismic Tower Section 1 - 1 88.25 9' x 2" Pipe Mount (E-Per Photos) 87.5 (2) 6' x 2" Mount Pipe (E-Per Photos) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 12' T-Arm (E) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 HBXX-6517DS-A2M w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 FFVV-65C-R3-V1 w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AEHC w/ Mount Pipe (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHFIG (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 AHLOA (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 TMAT1921B68-21-43 (P) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 9' x 2" Pipe Mount (E-Per Photos) 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic tower mounts 9' x 2" Pipe Mount 87.5 CCISeismic (2) tower mounts 6' x 2" Mount Pipe 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic 12' T-Arm 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic andrew HBXX-6517DS-A2M w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic commscope FFVV-65C-R3-V1 w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AEHC w/ Mount Pipe 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHFIG 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic nokia AHLOA 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic commscope TMAT1921B68-21-43 87.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (81.5ft to91.5ft) 86.5 CCISeismic Step Pegs From 11 to 91.5 (81.5ft to91.5ft) 86.5 CCISeismic (6) 7/8" From 8 to 87.5 (81.5ft to87.5ft) 84.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (81.5ft to87.5ft) 84.5 24" Stadium Light (E) 81 24" Stadium Light (E) 81 24" Stadium Light (E) 81 Standoff Mount (E) 81 CCISeismic Standoff Mount 81 CCISeismic Standoff Mount 81 CCISeismic Standoff Mount 81 CCISeismic 24" Stadium Light 81 CCISeismic 24" Stadium Light 81 CCISeismic 24" Stadium Light 81 Standoff Mount (E) 81 Standoff Mount (E) 81 CCISeismic Tower Section 1 - 2 80 Standoff Mount (E) 78 Standoff Mount (E) 78 CCISeismic Standoff Mount 78 CCISeismic Standoff Mount 78 CCISeismic Standoff Mount 78 24" Stadium Light (E) 78 24" Stadium Light (E) 78 CCISeismic 24" Stadium Light 78 CCISeismic 24" Stadium Light 78 CCISeismic 24" Stadium Light 78 24" Stadium Light (E) 78 Standoff Mount (E) 78 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (71.5ft to81.5ft) 76.5 CCISeismic Step Pegs From 11 to 91.5 (71.5ft to81.5ft) 76.5 CCISeismic (6) 7/8" From 8 to 87.5 (71.5ft to81.5ft) 76.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (71.5ft to81.5ft) 76.5 CCISeismic 3/4" DC From 8 to 81 (71.5ft to81ft) 76.25 CCISeismic Standoff Mount 75 CCISeismic Standoff Mount 75 Standoff Mount (E) 75 CCISeismic 24" Stadium Light 75 CCISeismic 24" Stadium Light 75 CCISeismic 24" Stadium Light 75 Standoff Mount (E) 75 Standoff Mount (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 24" Stadium Light (E) 75 CCISeismic Standoff Mount 75 CCISeismic Tower Section 1 - 3 70 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (61.5ft to71.5ft) 66.5 CCISeismic Step Pegs From 11 to 91.5 (61.5ft to71.5ft) 66.5 CCISeismic (6) 7/8" From 8 to 87.5 (61.5ft to71.5ft) 66.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (61.5ft to71.5ft) 66.5 CCISeismic 3/4" DC From 8 to 81 (61.5ft to71.5ft) 66.5 CCISeismic Tower Section 1 - 4 60 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (51.5ft to61.5ft) 56.5 CCISeismic Step Pegs From 11 to 91.5 (51.5ft to61.5ft) 56.5 CCISeismic (6) 7/8" From 8 to 87.5 (51.5ft to61.5ft) 56.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (51.5ft to61.5ft) 56.5 CCISeismic 3/4" DC From 8 to 81 (51.5ft to61.5ft) 56.5 CCISeismic Tower Section 1 - 5 50 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (41.5ft to51.5ft) 46.5 CCISeismic Step Pegs From 11 to 91.5 (41.5ft to51.5ft) 46.5 CCISeismic (6) 7/8" From 8 to 87.5 (41.5ft to51.5ft) 46.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (41.5ft to51.5ft) 46.5 CCISeismic 3/4" DC From 8 to 81 (41.5ft to51.5ft) 46.5 CCISeismic Tower Section 2 - 1 45 CCISeismic Step Pegs From 11 to 91.5 (31.5ft to41.5ft) 36.5 CCISeismic (6) 7/8" From 8 to 87.5 (31.5ft to41.5ft) 36.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (31.5ft to41.5ft) 36.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (31.5ft to41.5ft) 36.5 CCISeismic 3/4" DC From 8 to 81 (31.5ft to41.5ft) 36.5 CCISeismic Tower Section 2 - 2 35 CCISeismic Step Pegs From 11 to 91.5 (21.5ft to31.5ft) 26.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (21.5ft to31.5ft) 26.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (21.5ft to31.5ft) 26.5 CCISeismic (6) 7/8" From 8 to 87.5 (21.5ft to31.5ft) 26.5 CCISeismic 3/4" DC From 8 to 81 (21.5ft to31.5ft) 26.5 CCISeismic Tower Section 2 - 3 25 CCISeismic (6) 7/8" From 8 to 87.5 (11.5ft to21.5ft) 16.5 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (11.5ft to21.5ft) 16.5 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (11.5ft to21.5ft) 16.5 CCISeismic Step Pegs From 11 to 91.5 (11.5ft to21.5ft) 16.5 CCISeismic 3/4" DC From 8 to 81 (11.5ft to21.5ft) 16.5 CCISeismic Tower Section 2 - 4 15 CCISeismic Step Pegs From 11 to 91.5 (11ft to11.5ft) 11.25 CCISeismic miscl Safety Line 3/8 From 11 to 91.5 (11ft to11.5ft) 11.25 CCISeismic (2) HCS 2.0 Pendant From 8 to 87.5 (8ft to11.5ft) 9.75 CCISeismic (6) 7/8" From 8 to 87.5 (8ft to11.5ft) 9.75 CCISeismic 3/4" DC From 8 to 81 (8ft to11.5ft) 9.75 CCISeismic Tower Section 2 - 5 5 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in King County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 0.25 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. CCISeismic Note: Seismic loads generated by CCISeismic 3.3.2 9. CCISeismic Note: Seismic calculations are in accordance with ASCE 7-10 10. TOWER RATING: 39.4% SEISMIC LOADING DOES NOT CONTROL THE ANALYSIS ASCE 7 Hazards Report Address: No Address at This Location Standard:ASCE/SEI 7-10 Risk Category:II Soil Class:D - Stiff Soil Elevation:268.12 ft (NAVD 88) Latitude: Longitude: 47.320456 -122.360356 Wind Results: Data Source: Date Accessed: Wind Speed: 110 Vmph 10-year MRI 72 Vmph 25-year MRI 79 Vmph 50-year MRI 85 Vmph 100-year MRI 91 Vmph ASCE/SEI 7-10, Fig. 26.5-1A and Figs. CC-1–CC-4, incorporating errata of March 12, 2014 Tue Sep 22 2020 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-10 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-10 Section 26.2. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. Page 1 of 3https://asce7hazardtool.online/Tue Sep 22 2020 SS : 1.311 S1 : 0.504 F a : 1 F v : 1.5 SMS : 1.311 SM1 : 0.756 SDS : 0.874 SD1 : 0.504 T L : 6 PGA : 0.517 PGA M : 0.517 F PGA : 1 Ie : 1 Design Response Spectrum S (g) vs T(s)a MCE Response SpectrumR S (g) vs T(s)a Seismic Site Soil Class: Results: Seismic Design Category D - Stiff Soil D Data Accessed: Date Source: Tue Sep 22 2020 USGS Seismic Design Maps based on ASCE/SEI 7-10, incorporating Supplement 1 and errata of March 31, 2013, and ASCE/SEI 7-10 Table 1.5-2. Additional data for site-specific ground motion procedures in accordance with ASCE/SEI 7-10 Ch. 21 are available from USGS. Page 2 of 3https://asce7hazardtool.online/Tue Sep 22 2020 Ice Results: Data Source: Date Accessed: Ice Thickness: 0.25 in. Concurrent Temperature: 25 F Gust Speed: 30 mph Standard ASCE/SEI 7-10, Figs. 10-2 through 10-8 Tue Sep 22 2020 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 50-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 3 of 3https://asce7hazardtool.online/Tue Sep 22 2020 Morrison Hershfield RF DATA SHEET 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…1/13 Section 1 - Site Information Section 2 - Existing Template Images RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Site ID: SE04653A Status: Draft Version: 5 Project Type: Anchor Approved: Not Approved Approved By: Not Approved Last Modified: 8/31/2020 1:12:22 PM Last Modified By: Amith.Hegde3@T-Mobile.com Site Name: Lakota Park Site Class: Light Pole Site Type: Structure Non Building Plan Year: 2020 Market: SEATTLE WA Vendor: Nokia Landlord: City of Federal Way Latitude: 47.32045600 Longitude: -122.36035600 Address: 2100 SW 312th Street City, State: Federal Way, WA Region: WEST RAN Template: 56791EZ_U21 AL Template: 56791EZ_U21 Sector Count: 3 Antenna Count: 9 Coax Line Count: 0 TMA Count: 3 RRU Count: 6 N_701A_RUSh_1Hex_FRIJ.jpg DR A F T 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…2/13 Notes: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…3/13 Section 3 - Proposed Template Images 56791EZ_U21.jpg Notes: DR A F T 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…4/13 Section 4 - Siteplan Images ----- This section is intentionally blank. ----- DR A F T 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…5/13 Section 5 - RAN Equipment RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Existing RAN Equipment Template: 701A_Rxx_FRIJ Enclosure 1 2 3 Enclosure Type FCOA Cabinet (Nokia)Tower Top Mount (Nokia)2G Purcell support Baseband ESMB FSMF FSMF G1900 L2100 L700 U2100 Baseband Submodule FBBC FBBC L2100 L700 Hybrid Cable System NSN High Cap HCS 125ft Junction Box Large COVP (Nokia)Large COVP (Nokia) Radio FXFC (x 2 )FRLB (x 3 )FRIJ (x 3 ) G1900 L700 U2100 L2100 DR A F T 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…6/13 Proposed RAN Equipment Template: 56791EZ_U21 Enclosure 1 2 3 4 5 Enclosure Type Purcell HPL3 600A DC plant Tower Top Mount (Nokia)Ancillary Equipment (Nokia) Ground Mount (Nokia)Purcell LB3 Battery Cabinet (4 strings) Baseband ASIK ASIB ASIB ASIK ESMB FSMF N2500 L2500 L700 L600 L1900 L2100 LAWS3 (DARK) N600 G1900 U2100 Baseband Submodule ABIL (x 3 )ABIC (x 3 ) ABIA ABIL ABIA (x 2 ) N2500 L2500 L700 L600 N600 L1900 L2100 LAWS3 (DARK) Baseband Subrack AMIA (x 2 ) Hybrid Cable System Voltage Booster PowerPlus w/ 2 Amplifier Raycap 15' HCS 2.0 Jumper Cable - 10AWG 2PR Airscale (x 3 ) 15' HCS 2.0 Jumper Cable - 2x6AWG 2PR AHFIG (x 3 ) 15' HCS 2.0 Jumper Cable - 2x6AWG 4PR AEHC (x 3 ) 150' HCS 2.0 Trunk - 12#6AWG 24 SM FIBER PR (x 2 ) Junction Box Nokia HCS 2.0 Tower Junction Box (x 2 ) Power subsystem Rectifier Shelf *Select size* Breakers *Select size* Batteries *Select size* Radio AHLOA (x 3 ) AHFIG (x 3 ) FXFB FRIE L700 L600 N600 L1900 L2100 LAWS3 (DARK) G1900 U2100 Transport System CSR IXRe RAN Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…7/13 Section 6 - A&L Equipment RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Existing Template: 701A_RUSh_1Hex_FRIJ Proposed Template: 56791EZ_U21 Sector 1 (Existing) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 Antenna Model Andrew - SBNHH-1D65C-SR (Hex) Azimuth 0 M. Tilt 0 Height 90 Ports P1 P2 P3 Active Tech.U2100 L2100 G1900 U2100 L2100 G1900 L700 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt 4 4 4 Cables 7/8" LMU Coax - 145 ft. (x2) Fiber Jumper - 15 ft. (x2) Fiber Jumper - 15 ft.Fiber Jumper - 15 ft. TMAs Diplexers / Combiners CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) Radio TRX (Nokia) (At Cabinet) (x2) Sector Equipment Unconnected Equipment: Scope of Work: DR A F T 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…8/13 RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Sector 1 (Proposed) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 2 3 Antenna Model Commscope - FFVV-65C-R3-V1 (Octo)Andrew - HBXX-6517DS-A2M (Quad)AEHC (Active Antenna - Massive MIMO) Azimuth 0 0 0 M. Tilt Height 90 90 90 Ports P1 P2 P3 P4 P5 P6 P7 Active Tech.L700 L600 N600 L700 L600 N600 G1900 U2100 L1900 L2100 L1900 L2100 L2500 N2500 Dark Tech.LAWS3 LAWS3 Restricted Tech. Decomm. Tech. E. Tilt Cables TMAs CommS cope Twin Style 3CX - TMAT19 21B68- 21-43 (E14R0 0P09) (AtAnte nna) Diplexers / Combiners CommS cope AWS/P CS - ECC192 0-VPUB (AtCabi net) (x2) Radio Sector Equipment Unconnected Equipment: Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…9/13 RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Sector 2 (Existing) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 Antenna Model Andrew - SBNHH-1D65C-SR (Hex) Azimuth 120 M. Tilt 0 Height 90 Ports P1 P2 P3 Active Tech.U2100 L2100 G1900 U2100 L2100 G1900 L700 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt 4 4 4 Cables 7/8" LMU Coax - 145 ft. (x2) Fiber Jumper - 15 ft. Fiber Jumper - 15 ft. TMAs Diplexers / Combiners CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) Radio TRX (Nokia) (At Cabinet) (x2) Sector Equipment Unconnected Equipment: Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a6…10/13 RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Sector 2 (Proposed) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 2 3 Antenna Model Commscope - FFVV-65C-R3-V1 (Octo)Andrew - HBXX-6517DS-A2M (Quad)AEHC (Active Antenna - Massive MIMO) Azimuth 120 120 120 M. Tilt Height 90 90 90 Ports P1 P2 P3 P4 P5 P6 P7 Active Tech.L700 L600 N600 L700 L600 N600 G1900 U2100 L1900 L2100 L1900 L2100 L2500 N2500 Dark Tech.LAWS3 LAWS3 Restricted Tech. Decomm. Tech. E. Tilt Cables TMAs CommS cope Twin Style 3CX - TMAT19 21B68- 21-43 (E14R0 0P09) (AtAnte nna) Diplexers / Combiners CommS cope AWS/P CS - ECC192 0-VPUB (AtCabi net) (x2) Radio Sector Equipment Unconnected Equipment: Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a66…11/13 RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Sector 3 (Existing) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 Antenna Model Andrew - SBNHH-1D65C-SR (Hex) Azimuth 240 M. Tilt 0 Height 90 Ports P1 P2 P3 Active Tech.U2100 L2100 G1900 U2100 L2100 G1900 L700 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt 4 4 4 Cables 7/8" LMU Coax - 145 ft. (x2) Fiber Jumper - 15 ft. Fiber Jumper - 15 ft. TMAs Diplexers / Combiners CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) CommScope AWS/PCS - ECC1920-VPUB (AtAntenna) (x2) Radio TRX (Nokia) (At Cabinet) (x2) Sector Equipment Unconnected Equipment: Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a6…12/13 RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Sector 3 (Proposed) view from front (Note: the images show view from behind) Coverage Type A - Outdoor Macro Antenna 1 2 3 Antenna Model Commscope - FFVV-65C-R3-V1 (Octo)Andrew - HBXX-6517DS-A2M (Quad)AEHC (Active Antenna - Massive MIMO) Azimuth 240 240 240 M. Tilt Height 90 90 90 Ports P1 P2 P3 P4 P5 P6 P7 Active Tech.L700 L600 N600 L700 L600 N600 G1900 U2100 L1900 L2100 L1900 L2100 L2500 N2500 Dark Tech.LAWS3 LAWS3 Restricted Tech. Decomm. Tech. E. Tilt Cables TMAs CommS cope Twin Style 3CX - TMAT19 21B68- 21-43 (E14R0 0P09) (AtAnte nna) Diplexers / Combiners CommS cope AWS/P CS - ECC192 0-VPUB (AtCabi net) (x2) Radio Sector Equipment Unconnected Equipment: Scope of Work: 8/31/2020 SE04653A_Anchor_5_draft_2020-08-31 https://rfds-prod-web-core-secure.apps.px-prd02.cf.t-mobile.com/DataSheet/Printout/c34716bc-057c-4f30-83e2-0ba8be7fa3dd?layoutId=19a6…13/13 Section 7 - Power Systems Equipment RAN Template: 56791EZ_U21 A&L Template: 56791EZ_U21 SE04653A_Anchor_5_draft Print Name: Standard PORs: L600_CMP5 Anchor Existing Power Systems Equipment ----- This section is intentionally blank. ----- Proposed Power Systems Equipment DR A F T