Loading...
20-103656-Plan Set-09-23-2020-V1PROJECT INFORMATION SITE NAME: LAKOTA PARK SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 COUNTY: KING COUNTY LATITUDE: 47' 19' 13.6" N (47.320444') LONGITUDE: 122' 21' 37.2" W (-122.360333') GROUND ELEVATION: t260.0' AMSL STRUCTURE HEIGHT: 91'-6" (TOP OF POLE) JURISDICTION: FEDERAL WAY PARCEL: 1221039016 PARCEL SIZE: ±28.5 ACRES ZONING: SE OCCUPANCY: U CONSTRUCTION INFORMATION: AREA OF CONSTRUCTION: EXISTING/NO CHANGE CONSTRUCTION TYPE: V-B PROPOSED USE: UNMANNED TELECOMMUNICATIONS FACILITY HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED TOWER OWNER: CITY OF FEDERAL WAY 33325 8TH AVE SOUTH FEDERAL WAY, WA 98003 PROPERTY OWNER: CITY OF FEDERAL WAY 33325 8TH AVE SOUTH FEDERAL WAY, WA 98003 APPLICANT: T-MOBILE 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 PROJECT TEAM SITE ACQUISITION: PROJECT CONSULTANT RYKA CONSULTING MORRISON HERSHFIELD CORP. 5628 AIRPORT WAY S, SUITE 112 600 STEWART ST, SUITE 200 SEATTLE, WA 98108 SEATTLE, WA 98101 CONTACT: JESSICA PIERCE CONTACT: ROY LORETE PHONE: (206) 523-1941 PHONE: (206) 708-9031 r1 orete®mo rri so n h ers hf i eld. com PERMITTING: ENGINEER: RYKA CONSULTING G. LANCE COOKE 5628 AIRPORT WAY S, SUITE 112 MORRISON HERSHFIELD CORP. SEATTLE, WA 98108 PHONE (503) 595-9128 CONTACT: CHRISTINE CONTRERAS Icooke®morrisonhershfield.com PHONE: (206) 523-1941 ccontreras@rykaconsulting.com T—MOBILE CONSTRUCTION MANAGER ARCHITECT: T-MOBILE ROBERT LARA CONTACT: WALTER DARBY MORRISON HERSHFIELD CORP. PHONE:(425) 279-3533 PHONE (954) 577-4655 SITE NAME: LAKOTA PARK SITE ADDRESS T-MOBILE SITE NUMBER PROJECT VICINITY MAP L A K 0 1 A 0 ADELAIDE BUENNA ¢a � y � a l T MIRROR LAKE H JSW3121 I r. S;T rLi v� Lakota Middle School SW 32Drk St `: SW anh S! T -'k r i NOT TO SCALE NORTH SCOPE OF WORK T-MOBILE PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY WITH THE FOLLOWING: TOWER SCOPE: • REPLACE (3) HEX W/ (3) OCTO • INSTALL (3) QUAD • INSTALL (3) AEHC ACTIVE ANTENNA/RADIO • REMOVE (3) FRIJ, (3) FRLB, (1) FXFB • RELOCATE (1) FXFB TO GRADE LEVEL POWER UPGRADE NOTE: • INSTALL (3) AHFIG, (3) AHLOA EXISTING 100A AC SERVICE • REMOVE (1) COVP TO BE UPGRADED TO 200A • REMOVE (6) DIPLEXER PER SEPARATE ELECTRICAL • RELOCATE (6) DIPLEXER TO GRADE LEVEL SERVICE UPGRADE SCOPE • INSTALL (3) STYLE 3CX TMA OF WORK/DESIGN, UNDER • REMOVE (1) HCS 1.0 SEPARATE ELECTRICAL • INSTALL (2) HCS 2.0 CABLES W/ PENDANTS PERMIT AS REQUIRED, TO • INSTALL (6) 7/8" COAX BE INCLUDED IN NTP GROUND SCOPE: • UPGRADE POWER TO 200A • REPLACE EXISTING PPC W/ NEW EMERSON PPC • REMOVE (1) PURCELL RAC72, (1) ULTRASITE, AND (1) FCOA CABINET • INSTALL (1) PURCELL HPL3 600A DC POWER CABINET, (1) LB3 BATTERY CABINET • REMOVE (1) 1.0 HIGH -CAP COVP • INSTALL (2) 2.0 JUNCTION BOXES • INSTALL (1) VOLTAGE BOOSTER FOR LTE • REPLACE EXISTING TELCO BOX W/ AAV CUBE AND RELOCATE LEC ROUTER TO CUBE; COORDINATE W/ CM • UPGRADE 7210 SAS-MXP TO IXRE • RELOCATE ESMB AND FSMF FROM OLD PURCELL TO NEW HPL3; CHECK VERSION COMPATIBILITY FOR RE -USE • INSTALL (1) FIRE • REMOVE/INSTALL BASE BAND MODULES PER RFDS DESIGN BASED ON: RFDS ANCHOR VERSION 5, DATED 08/31/2020 1:12:22 PM 31334 SW DASH POINT RD FEDERAL WAY. WA 98023 SE04653A ANCHOR/ L600 DIRECTIONS DIRECTIONS TO SITE (FROM T-MOBILE OFFICE, BOTHELL, WA): • HEAD SOUTH ON 120TH AVE NE • TURN RIGHT ONTO NE 195TH ST • USE THE LEFT 2 LANES TO TURN LEFT ONTO THE INTERSTATE 405 S RAMP TO RENTON • MERGE WITH 1-405 S • KEEP LEFT TO STAY ON 1-405 S • KEEP RIGHT TO STAY ON 1-405 S • TAKE THE EXIT ONTO 1-5 S TOWARD PORTLAND • TAKE EXIT 147 FOR S 272ND ST • TAKE EXIT 147 FOR S 272ND ST • USE THE LEFT 2 LANES TO TURN LEFT ONTO HWY 99 S/WA-509/PACIFIC HWY S • TURN RIGHT ONTO S DASH POINT RD • TURN LEFT AT 21ST AVE SW APPROVALS APPROVAL SIGNATURE DATE PROJECT MANAGER T-MOBILE RF ENGINEER SITE ACQUISITION CONSTRUCTION MANAGER SITE OWNER T-MOBILE DEVELOPMENT MANAGER T-MOBILE CONSTRUCTION MANAGER T-MOBILE OPS MANAGER T-MOBILE REGULATORY REVIEW T-MOBILE PROJECT MANAGER INDEX OF DRAWINGS SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES A-1 SITE PLAN A-1.1 ENLARGED PLAN A-1.2 EQUIPMENT PLAN A-2 TOWER PROFILE A-3 CONSTRUCTION DETAILS A-4 CONSTRUCTION DETAILS A-5 CONSTRUCTION DETAILS A-6 CONSTRUCTION DETAILS A-7 CONSTRUCTION DETAILS A-8 CONSTRUCTION DETAILS RF-1 ANTENNA CONFIGURATION RF-2 PLUMBING DIAGRAM RF-3 TYPICAL SECTOR SFP E-1 EQUIPMENT ELECTRICAL/GROUNDING PLAN E-2 WIRING DIAGRAMS E-3 WIRING DIAGRAMS ANTENNA GROUNDING SCHEMATIC GROUNDING DETAILS E-4 E-5 CODE COMPLIANCE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: WASHINGTON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 INTERNATIONAL FIRE CODE (IFC) 2017 NATIONAL ELECTRIC CODE (NFPA 70) CONTRACTOR TO CALL TO VERIFY UTILITIES AT Q Q LEAST TWO WORKING DAYS PRIOR TO DIGGING Know what's below. Call before you dig. DO NOT SCALE DRAWINGS CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. T0-Mobl. 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#CONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhemhfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: TITLE SHEET SHEET NUMBER: T-1 ARCHITECTURAL GENERAL NOTES ELECTRICAL GENERAL NOTES COMPOUND NOTES 1. WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL NECESSARY LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. 2. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS AND CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS CONTRACT. ALL MANUFACTURERS RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS HEREIN, WHERE MOST STRINGENT SHALL BE COMPLIED WITH. 3. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND ALL MECHANICAL, ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY CONFLICTS. THE CONSULTANT HAS THE RIGHT TO MAKE MINOR MODIFICATIONS IN THE DESIGN OF THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL COMPENSATION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS FROM THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING, SITE, AND ANY OTHER SURROUNDING AREAS TO A BETTER THAN NEW CONDITION. 5. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 6. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN THE SPECIFICATIONS, UNLESS NOTED OTHERWISE. 7. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 8. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY. 9. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY OWNER'S REQUIRED DATE, THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY CONNECTION IS COMPLETED. COSTS ASSOCIATED WITH THE TEMPORARY GENERATOR TO BE APPROVED BY THE OWNER. 10. PLANS PART OF THIS SET ARE COMPLEMENTARY. INFORMATION IS NOT LIMITED TO ONE PLAN. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO MORRISON HERSHFIELD. THESE PLANS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO BUILD ACCORDING TO APPLICABLE BUILDING CODES. 11. IF CONTRACTOR OR SUB -CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN IT IS THE CONTRACTOR'S AND THE SUB -CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH (4) COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 12. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR, SUB -CONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB WHEN ADDITIONAL ITEMS ARE REQUIRED TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A COMPLETE, ADEQUATE AND SAFE WORKING CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE DRAWINGS. FOR EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE SIZE (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED QUANTITY (I.E. STRUCTURAL ELEMENTS), REDUCED SPACING, AND/OR INCREASED LENGTH (I.E. BOLT LENGTHS, BAR LENGTHS) THEN IT SHALL BE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE BID/PROPOSAL. THESE DOCUMENTS ARE MEANT AS A GUIDE AND ALL ITEMS REASONABLY INFERRED SHALL BE DEEMED TO BE INCLUDED. 13. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR. A. GENERAL 1. EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF PROPOSED WORK TOGETHER WITH THE WORK OF ALL OTHER TRADES AND INCLUDE IN THE BID PRICE ALL COSTS FOR WORK SUCH AS EQUIPMENT AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS SHOWN AND SYSTEMS OF OTHER TRADES. 2. OBTAIN ALL PERMITS, PAY ASSOCIATED FEES AND SCHEDULE INSPECTION. 3. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, INSURANCE, AND SERVICES TO COMPLETE THIS PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND PRESENT IT AS FULLY OPERATIONAL TO THE SATISFACTION OF T-MOBILE & LAND/TOWER OWNER 4. PRIOR TO BEGINNING WORK COORDINATE ALL POWER AND TELCO WORK WITH THE LOCAL UTILITY COMPANY AS IT MAY APPLY TO THIS SITE. ALL WORK TO COMPLY WITH THE RULES AND REGULATIONS OF THE UTILITIES INVOLVED GENERAL CONTRACTOR IS RESPONSIBLE FOR VED. REQUESTING CONNECTION OF COMMERCIAL POWER FROM THE POWER COMPANY. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WORK WITH THE GENERAL CONTRACTOR. 5. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST CLASS WORKMANSHIP PER NECA STANDARD 1-2000 BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE PROGRESS OF THE PROJECT. B. BASIC MATERIALS AND METHODS 1. ALL ELECTRICAL WORK SHALL CONFORM TO THE EDITION OF THE NEC ACCEPTED BY THE LOCAL JURISDICTION AND TO THE APPLICABLE LOCAL CODES AND REGULATIONS. 2. ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS SHOWN, PROVIDING PROPER CLEARANCES AND ACCESS. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH LOCATION WITHOUT SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF FIELD CONDITIONS OR OTHER CAUSES, PREPARE AND SUBMIT DETAILED DRAWINGS FOR ACCEPTANCE. 3. THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS, BENDS, FITTINGS AND ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT THE WORK TO THE CONDITIONS. 4. SEAL AROUND CONDUITS AND AROUND CONDUCTORS WITHIN CONDUITS ENTERING THE MODULAR CABINETS WHERE PENETRATION OCCURS WITH A SILICONE SEALANT TO PREVENT MOISTURE PENETRATION INTO BUILDING. C. CONDUCTORS AND CONNECTORS 1. UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER, MINIMUM SIZE #12 AWG, WITH THERMOPLASTIC INSULATION CONFORMING TO NEMA WC5 OR CROSS -LINKED POLYETHYLENE INSULATION CONFORMING TO NEMA WC7. (TYPES THHN). INSULATION SHALL BE RATED FOR 90 DEG. CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC. 2. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. SPLICES ARE NOT ACCEPTABLE. IF SPLICES ARE UNAVOIDABLE PRIOR APPROVAL FROM THE ENGINEER MUST BE OBTAINED. D. GROUNDING 1. ALL LIGHTNING PROTECTION GROUNDING OF THE ELECTRICAL EQUIPMENT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE CURRENT NFPA STANDARDS. 2. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH ANTI -OXIDANT AGENT, SUCH AS NO-OX, NOALOX, PENETROX OR KOPRSHIELD. 3. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING SHALL BE #2 AWG SOLID BARE TINNED COPPER. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE LESS THAN 8" AND THE ANGLE OF ANY BEND SHALL NOT EXCEED 90'. GROUNDING CONDUCTORS SHALL BE ROUTED DOWNWARD TOWARD THE BURIED GROUND RING. 4. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY THERMO-WELDING WITH ERICO T-319 GALVANIZING BAR. 5. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC WELDS TO EXTERIOR GROUND RING SHALL BE THE PARALLEL TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE TEE EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING. USE SPRAY GALVANIZER SUCH AS HOLUB LECTROSOL #15-501. 1. CONTRACTOR AND SUBCONTRACTORS SHALL VERIFY ALL UTILITY SERVICE CONNECTION LOCATIONS PRIOR TO SUBMITTING BID AND PROCEEDING WITH WORK. IT IS RECOMMENDED THAT THE CONTRACTOR VISIT THE SITE AND VERIFY ALL DIMENSIONS AND NOTES BEFORE SUBMITTING BID AND PROCEEDING WITH WORK. 2. SOIL AT THIS SITE IS UNDISTURBED ROCK AND SAND ADEQUATE OF SUPPORTING THE DESIGN LOAD OF 2000 P.S.F. IF OTHER CONDITIONS ARE ENCOUNTERED, NOTIFY MORRISON HERSHFIELD BEFORE PROCEEDING WITH WORK. THIS VALUE IS CONSIDERED SAFE WITH RESPECT TO ACTUAL FAILURE OF THE SUPPORTING GROUND, BUT DOES NOT NECESSARILY ENSURE THE PREVENTION OF EXCESSIVE FOUNDATION MOVEMENTS. 3. IN ORDER TO AVOID ANY CONFLICTS, CONTRACTOR SHALL COORDINATE ALL HIS PRACTICAL TRADES. 4. THE POWER CABINET MUST BE CLEAR OF FLAMMABLE MATERIAL WITHIN 12 INCHES OF THE CABINET, INCLUDING ABOVE THE CABINET. 5. THE POWER CABINET MUST BE MOUNTED ON THE FOUNDATION TO ALLOW WATER TO DRAIN FROM THE DRAIN OUTLET AND AWAY FROM THE CABINET. 6. TO ENSURE SERVICEABLE ABILITY, THE DOORS OF CABINETS WILL REQUIRE AN OPENING RADIUS OF 36 INCHES OF CLEARANCE FROM THE CLOSED POSITION TO THE OPEN POSITION. SITE GENERAL NOTES 1. RESTORE EXISTING ASPHALT AND/OR CONCRETE COMPOUND TO IT'S ORIGINAL CONDITION. 2. CONTRACTOR SHALL DETECT AND MARK ANY UNDERGROUND LINES, PIPING, PRIOR TO START OF EXCAVATION. PROJECT INFORMATION 1. THIS IS AN UNMANNED AND RESTRICTED ACCESS EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 2. THIS FACILITY WILL CONSUME NO UNRECOVERABLE ENERGY. 3. NO POTABLE WATER SUPPLY IS TO BE PROVIDED AT THIS LOCATION. 4. NO WASTE WATER WILL BE GENERATED AT THIS LOCATION. 5. NO SOLID WASTE WILL BE GENERATED AT THIS LOCATION. 6. T-MOBILE MAINTENANCE CREW (TYPICALLY ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER VISIT. IMPORTANT NOTICE THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY OTHERS. MORRISON HERSHFIELD CORPORATION CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB -CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. T 1VMo_a1 k 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#CONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: GENERAL NOTES SHEET NUMBER: T-2 NOTE: THIS IS NOT A SURVEY. ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND JURISDICTIONAL CIS INFORMATION AND ARE APPROXIMATE. LEGAL DESCRIPTION: NE 1/4 OF SE 1/4 LESS POR NWLY OF ROBT MALTBY RD & SWLY OF CO RD # 980 & NLY OF DUMAS BAY RD LESS CO RDS & LESS NW LY 22 FT FOR RD PER REC #20160620000489 . --- T TAX PARCEL: 1789800015 TAX PARCEL: 1789,800010 TAX PARCEL: 1789800005 ,j 7 EXISTING LANDSCAPE AREA EXISTING BLDG (TYR) TAX PARCEL: 1221039147 {' \. ./,,EXISTING AREA LANDSCAPE TAX PARCEL: 1221039052 EXISTING 1111 1AN LOT EXISTING DAL FIELD TAX PARCEL TAX PARCEL: 1221039016 1221039059 A 2 A EXISTING T—MOBILE LAKCITA PARI FENCED EQUIPMENT AREA EXISTING 91-6" STEEL LIGHT POLE TOPT—MOBILE INSTALLATION AT OF POLE TAX PARCEL: 1221039057 TAX PARCEL: 1221039054 TAX PARCEL: 55 12210390 J� 24:06" SCALE: 1: = 80'-0" 11 X17* SCALE: I - 160'-0" 8 4 0. 04 -Axr EXISTING TREE (TYP) L;UVEH EXISTING LANDSCAPE AREA PROPER LINE (TY )_ _ _ _ _ — -- — -- — -- — -- S W 6') EXISTING SPORT FIELD L--- — — — — A 3 1 2 T H S T/—EXISTING ADJACENT PROPERTY LINE (7YP) TAX PARCEL: 0721049209 I , I 'I TAX PARCEL: 0721049143 T Mo 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 RYKA#CONSULTM PLANS PREPARED BY: I PAN MORRISON HERSHFIELE) 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrisonhemhfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA I I SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL N PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: SITE PLAN SHEET NUMBER: Know what's below. Call before you dig. A-1 SITE PLAN 11 - ' " `"°. ems• O 0 0 EXISTING PARKING X ° ° 9a• a o LOT EXISTING TRAFFIC ° ° M"4"s pooh• SIGNAL POLE X X X X " - ^•es•v a= o X X x X X x X x ❑ ❑ x X EXISTING 8" WOOD El X EXISTING TREE (TYP) POST (TYP) 103 x X X X X x Imo__ X FIELD VERIFY EXISTING CONDUIT ROUTE X l5 x EXISTING T-MOBILE FEEDLINES [(1) HCS 1.0 CABLE] / / 'A f -� �� EXISTING T-MOBILE ROUTED WITHIN UNDERGROUND CONDUITS / // nt� r� X X X 17'-0"x20'-0" x REMOVE FEEDLINE / // X ��� X X FENCED COMPOUND e 'A x X X x PROPOSED T-MOBILE FEEDLINES / / X X x X EXISTING TREE (TYP) ROUTED HWITHNOEXISTING CONDUI7/8 T 'A X EXISTING SHRUB (TYP) / EXISTING LANDSCAPE AREA EXISTING 91'-6" STEEL LIGHT POLE 24"06" SCALE: 3/16" = 1'-0" 11"07' SCALE: 3/32" - 1'-0" 4' 2' 0" 4 EXISTING CABLE ENTRY ENCLOSURE AT GRADE MOBILE ANTENNAS AND ANCILLARY UIPMENT ON EXISTING T-ARM MOUNT NOTES: _ 1. CONTRACTOR IS RESPONSIBLE FOR COMPLYING ®_ WITH ALL FEDERAL, STATE AND LOCAL CODES 0 0 ee - 2. CONTRACTOR IS RESPONSIBLE FOR PULLING ALL \ , REQUIRED PERMITS AND ARRANGING FOR ALL • "ems INSPECTIONS AND OBTAINING ALL APPROVALS 3. CONTRACTOR SHALL LOCATE AND MARK ANY UNDERGROUND UTILITIES PRIOR TO EXCAVATION 19807 NORTH CREEK PKWYN BOTHELL, WA 98011 1 N RYKA#OONSUL"TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: ENLARGED PLAN NOTES: PLAN INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT SHEET NUMBER: NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED _ ■ COMPOUND PLAN INFROMATION. ENLARGED PLAN 1 EXISTING T-MOBILE I OOA METER EXISTING FENCE OPENING EXISTING T-MOBILE 100A DISCONNECT EXISTING T-MOBILE UTILITY H-FRAME EXISTING GEN PLUG TO BE REPLACED EXISTING T-MOBILE CONDUIT STUB -UP (BELOW) (TYR OF 6) EXISTING T-MOBILE ICE BRIDGE TO BE MODIFIED EQUIPMENT SCOPE: • REPLACE EXISTING PPC W/ NEW EMERSON PPC • REMOVE (1) PURCELL RAC72, (1) ULTRASITE, AND (1) FCOA CABINET • ADD (1) PURCELL HPL3 600A DC POWER CABINET AND (1) LB3 BATTERY CABINET • REMOVE (1) 1.0 HIGH -CAP COVP • ADD (2) 2.0 JUNCTION BOXES • ADD (1) VOLTAGE BOOSTER FOR LTE • REPLACE EXISTING TELCO BOX W/ AAV CUBE AND RELOCATE LEC ROUTER TO CUBE; COORDINATE W/ CM/PIONEER PRIOR TO COMPLETING ANY WORK • UPGRADE 7210 SAS-Mxp TO IXRe • RELOCATE ESMB AND FSMF FROM OLD PURCELL TO NEW HPL3; CHECK VERSION COMPATIBILITY FOR RE -USE • RELOCATE (1) FXFB FROM TOWER TO H-FRAME AND ADD WEATHERPROOF SLEEVE • ADD (1) FRIE TO H-FRAME AND ADD WEATHERPROOF SLEEVE • ADD (6) RELOCATED DIPLEXERS FROM TOWER TOP TO H-FRAME • REMOVE/INSTALL BASE BAND MODULES PER RFDS • ANY UNUSED SYSTEM MODULES SHALL BE REMOVED POWER UPGRADE NOTE: EXISTING 100A AC SERVICE IS TO BE UPGRADED TO 200A PER SEPARATE ELECTRICAL SERVICE UPGRADE SCOPE OF WORK/DESIGN, UNDER SEPARATE ELECTRICAL PERMIT AS REQUIRED, TO BE INCLUDED IN NTP EXISTING T-MOBILE COVE TO BE REMOVED EXISTING T-MOBILE CABLE SUPPORT FRAME TO BE REMOVED, SEE NOTE EXISTING T-MOBILE ANTEN EXISTING TELCO BOX �GPS�TONBE REMOVED TO BE REPLACED EXISTING T-MOBILE FCOA CABINET PROPOSED T-MOBILE FRIE IN WEATHERPROOF SLEEVE ePROPOSED T-MOBILE HCS 2.0 A-4 JUNCTION BOX (TYP OF 2) 93 A-4 PROPOSED AAV CUBE NOTES: _ 1. CONTRACTOR IS RESPONSIBLE FOR COMPLYING ®_ WITH ALL FEDERAL, STATE AND LOCAL CODES ® 0 0 ee - 2. CONTRACTOR IS RESPONSIBLE FOR PULLING ALL \ , REQUIRED PERMITS AND ARRANGING FOR ALL ' •ems INSPECTIONS AND OBTAINING ALL APPROVALS 3. CONTRACTOR SHALL LOCATE AND MARK ANY UNDERGROUND UTILITIES PRIOR TO EXCAVATION 19807 NORTH CREEK PKWYN BOTHELL, WA 98011 1 1 RYKA*ODNSUL.TMWG CABLE SUPPORT FRAME NOTES: 1. ATTACH UNISTRUT TO ICE BRIDGE POSTS W/ 1/2" U-BOLTS 2. RE -USE/ FIELD CUT EXISTING UNISTRUT AS NEEDED 3. FIELD VERIFY ALL DIMENSIONS RELOCATED T-MOBILE FXFB IN WEATHERPROOF SLEEVE EXISTING T-MOBILE 100A METER PER EXISTING PPC/PANEL UPGRADED AS UPGRADED SCOPE LOFTWORK YTO BE REPLACED 7'-4"t 2'-0"t EXISTING FENCE OPENING CONC PAD — EXISTING DOUBLE SWING GATE EXISTING T-MOBILE 3' -0" 100A DISCONNECT CLEAR UPGRADED AS REQUIRED PER — ELECTRICAL UPGRADE SCOPE OF WORK — 2" MIN II -- 2 PROPOSED 200A EMERSON PPC; I1 A_4 SEE POWER UPGRADE NOTE '---- _ BATTERY PROPOSED CAMLOC 600A DC Lp — — 2' 11" a i 41 CABINET CABINET o EXISTING T-MOBILE CONDUIT I— 1 1 z \ STUB -UP (BELOW) A_6 6) — U RELOCATED DIPLEXER ON EXISTING FRAME BELOW ICE BRIDGE .o.. (TYP OF 6) _ EXISTING T-MOBILE CONDUIT STUB -UP (BELOW) •a, .'•. • '..,' 0.. " (TYR OF 6) •q ^•. • ; .'.`�. , .. e' . EXISTING MODIFIED J T-MOBILE ICE BRIDGE (SHORTENED) 12'-O" t CONC PAD EXISTING T-MOBILE ULTRASITE CABINET TO BE REMOVED EXISTING WOOD FENCE EXISTING WOOD FENCE EXISTING T-MOBILE PURCELL RAC72 CABINET TO BE REMOVED •RELOCATE LEC ROUTER TO NEW AAV CUBE; COORDINATE W/ CM •UPGRADE 7210 SAS-Mxp TO IXRe -RELOCATE ESMB AND FSMF TO NEW HPL3; CHECK VERSION COMPATIBILITY FOR RE -USE 24"x36" SCALE: 3/8" = 1'-0" 11"07" SCALE: 3/16" = 1'-0" 2' 1' 0 2' EXISTING EQUIPMENT PLAN 1 2 ?;�x;; SCALE: 3/i6" _ °o" 2®• EXISTING T-MOBILE GPS ANTENNA INSTALL IN HPL3: •RELOCATED LEC ROUTER • IXRe -RELOCATED ESMB AND FSMF PROPOSED T-MOBILE CABLE SUPPORT FRAME BELOW ICE BRIDGE, SEE NOTE 6 PROPOSED ICE BRIDGE A-4 EXISTING DOUBLE SWING GATE PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 9OX REVIEW BA 0 09/21/20 1OOX FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: EQUIPMENT PLAN NOTES: PLAN INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT SHEET NUMBER: NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED �_ ■ COMPOUND PLAN INFROMATION. PROPOSED EQUIPMENT PLAN 11 PROPOSED T-MOBILE AHFIG MOUNTED BEHIND ANTENNA A-3 (TYP OF 3, 1 PER SECTOR) EXISTING T-MOBILE DIPLEXER (TYP OF 12, 4 PER SECTOR) LIGHTNING ROD a PROPOSED T-MOBILE STYLE 3CX TMA LIGHTNING ROD PROPOSED T-MOBILE AEHC 4 (6) TO BE REMOVED A-3 (TYP OF 3, 1 PER SECTOR) (6) TO BE RELOCATED TO GRADE LEVEL EXISTING T-MOBILE FRIJ ACTIVE ANTENNA/RADIO A-3 (TYP OF 3, 1 PER SECTOR) (TYP OF 3, 1 PER SECTOR) TOP OF EXISTING TO BE REMOVED TOP OF PROPOSED ,JkT-MOBILE ANTENNAS T-MOBILE ANTENNAS EXISTING T-ARM MOUNT (TYP) t91'-6" AGL t91'-6" AGL TOP OF EXISTING POLE TOP OF EXISTING POLE t91'-6" AGL n t91'-6" AGL II BAD CENTER OF EXISTING I I RAIDCENTER OF PROPOSED r6T-MOBILE ANTENNAS T-MOBILE ANTENNAS I. t87'-6" AGL I I t87'-6" AGL I I � EXISTING T-ARM MOUNT (TYP) PROPOSED T-MOBILE AHLOA-ZW EXISTING T-MOBILE PANEL ANTENNA TO REMAIN MOUNTED BEHIND ANTENNA [ANDREW SBNHH-1D65C-SR (HEX)] A-3 (TYP OF 3, 1 PER SECTOR) e (TYP OF 3, 1 PER SECTOR) EXISTING T-MOBILE FRLB TO BE REMOVED (TYP OF 3, 1 PER SECTOR) 3 PROPOSED T-MOBILE PANEL ANTENNA TO BE REMOVED A_3 [COMMSCOPE FFW-65C-R3-V1 (OCTO)] (TYP OF 3, 1 PER SECTOR) 2 PROPOSED T-MOBILE PANEL ANTENNA A_3 [ANDREW HBXX-6517DS-A2M (QUAD)] (TYP OF 3, 1 PER SECTOR) EXISTING STADIUM LIGHT (TYP) EXISTING STADIUM LIGHT (TYP) EXISTING 9I �SX ETLNGIGHT POLE STEEL LIGHTT PO POLE EXISTING T-MOBILE FEEDLINES PROPOSED T-MOBILE FEEDLINES [(1) HCS 1.0 CABLE] [(2) HCS 2.0, (6) 7/8" COAX] ROUTED WITHIN POLE ROUTED WITHIN POLE REMOVE FEEDLINE EXISTING CABLE EXISTING CABLE I / ENTRY ENCLOSURE ENTRY ENCLOSURE h GRADE -L � I GRADE ASSUMED 0'-0" ASSUMED 0'-0" NOTES, 1. INFORMATION CONTAINED HEREIN IS TAKEN FROM THE DOCUMENTS PROVIDED BY CLIENT. NEITHER WARRANTY NOR GUARANTEE IS GIVEN BY THE ARCHITECT NOR MORRISON HERSHFIELD CORPORATION TO THE ACCURACY NOR THE COMPLETENESS OF THE COPIED ELEVATION INFORMATION. 2. NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT SIGNED AND SEALED BY A LICENSED PROFESSIONAL ENGINEER UNDER SEPARATE COVER. IF REQUIRED, THE CONTRACTOR SHALL MODIFY TOWER AND/OR ANTENNA MOUNTS AS INDICATED IN THE ABOVE MENTIONED STRUCTURAL REPORT OR ASSOCIATED MODIFICATION DESIGN DRAWINGS. T mo---'a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSaTMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 www. morrison h ershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: TOWER PROFILE SHEET NUMBER: 2 24"06" SCALE: 3/16" = 1'-0" 11"07" SCALE: 3/32" - 1'-0" 4' 2' 0" 4 EXISTING TOWER PROFILE 1 2 1 11�07" SCALE; 3/32" = 4'© PROPOSED TOWER PROFILE 1 1 ANILNNA IILI UKAUKLI (_A BY ANTE PIPE MOUNTING BRACKETS BY ANTENNA MFRM PANEL ANTENNA MOUNTING PIPE NOTE: MOUNT UNIT PER MANUFACTURER'S RECOMMENDATIONS MOUNTING HARDWARE PROVIDED BY EQUIPMENT MFR 12.1 a TOP MANUFACTURER: NOKIA MANUFACTURER: NOKIA MODEL: AHLOA RADIO MODEL: AHFIG RADIO e WEIGHT: 83.8 LBS WEIGHT: 79.4 LBS ®-- DIMENSIONS (HxWxD): 22.1"02.1"x7.4" DIMENSIONS (HxWxD): 27.6" x 13.4" x 5.6" FREQUENCY: REFER TO RF DATA SHEET FREQUENCY: REFER TO RF \/'�/_ I DATA SHEET v ` NOTE: MOUNT PER MANUFACTURER'S SPECIFICATIONS NOTE: 19807 NORTH CREEK PKWYN MOUNT PER MANUFACTURER'S SPECIFICATIONS BOTHELL, WA 98011 1 1 e� 13.4" RYKA#OONSUL.TMWG j TOP 7.4" PIPE 0 N N N FRONT SIDE FRONT ISOMETRIC SIDE 121"x17" SCALE: NTS TYP ANTENNA MOUNTING 8 " SCALE: NTS 11 .17" SCALE: NTS TYP RADIO MOUNTING 7 11SCALE: NTS X17" SCALE: NTS AHLOA 6 11 x17:: Ste: NTS AHFIG 5 11"x17" SCALE: NTS MANUFACTURER: NOKIA 11 MANUFACTURER: COMMSCOPE MANUFACTURER: ANDREW MODEL NOKIA AIRSCALE MAA 64T64R 192AE B41 320W AEHC N MODEL: FFW-65C—R3—V1 MODEL: HBXX-6517DS—A2M MANUFACTURER: COMMSCOPE WEIGHT: 108 LBS (W/O MOUNTING BRACKETS) N WEIGHT: 124.561 LBS (WITHOUT MOUNTING KIT) WEIGHT: 40.8 LBS MODEL: TMAT1921 B68-21-43/ E14ROOP09 DIMENSIONS: 38.2" x 21.5" x 5.9" of DIMENSIONS (LxWxD): 95.945" x 25.197" x 9.252" DIMENSIONS (LxWxD): 75.0" x 12.0" x 6.5" SIZE: 8.7"x4.2"x9.1" FREQUENCY: REFER TO RF DATA SHEET FREQUENCY: REFER TO RF DATA SHEEP FREQUENCY: REFER TO RF DATA SHEEP WEIGHT: 15.7 LBS (WTHOUT MOUNTING KIT) 25.197" 16 TOP 25.1 s7" 9.252" TOP ^I � 12.0" 6.5' v O 21.5" I I I I 8.7" 17---1 17-1 TOP VIEW FRONT SIDE FRONT SIDE EL a m Ol FRONT VIEW SIDE VIEW FRONT SIDE 24"x36" SCALE: NTS AEHC ACTIVE ANTENNA/RADIO 4 11 xl,. Ste; ws ANTENNA SPECIFICATIONS 3 11 X17" SCALE: NTS ANTENNA SPECIFICATIONS 11"x17 SCALE: NTS TMA SPECIFICATIONS 1 11"x17" SCALE: NTS PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: A-3 NOTE: EQUIPMENT CABINET(S) TO BE MECHANICALLY ATTACHED PER MANUFACTURER'S RECOMMENDATIONS GALV. BOX FRAME 5/8"0 HILTI KB—TZ EXPANSION HOT DIPPED GALVANIZED STEEL GRATING;PART OF CABINET BOLTS (4-1/8" EMBED) INTO CONC USE APPROVED PRE —MANUFACTURED KIT OR PUNTH BY VALMONT OR APPROVED EQUAL /(4) CONC SLAB 10"x10"x5/8" 3-1/2" SCH 40 GALVANIZED GALVANIZED PIPE 3-1/2"0 SCH 40 HOT DIPPED BASE PLATE GALVANIZED PIPE FOR ICE BRIDGE z SUPPORT WITH END CAP o � 1/4" (4) 5/8" HILTI HVA �j ADHESIVE BOLTS, MIN 12" H x 3/8" THK NTO/CONCRETE MENT WELDED GUSSE (TYP OF 2 PER LEG) 1/4" 2" 10"x10"x5/8" GALVANIZED 12" H x 3/8" THK BASE PLATE ON BED OF WELDED GUSSET PLATE LEVELING GROUT (TYP OF 2 PER LEG) 10"x10"4/8" ,/ GALVANIZED BASE PLATE T.O. CONC a e " 24"x36" SCALE` NTS 11"x17" SCALE: NTS CABINET ATTACHMENT 17 POWER CORD xx CABLE LENGTH PENDANT RRU ENL7 END � HQLC CONNECTOIR 'LC FLEX CONNECTORS %V1 BOOT MANUFACTURER: NWS MODEL: — WEIGHT: 1.61 LB/FT DIMENSIONS: 10.2"x 16.0"x3.2" 0.2" I MOUNTING KIT BY MFR inn PIPE ,O 1111"x17" SCALE: NTS ICE BRIDGE 161 11"x17" SCALE: NTS I I I I SCALE: NTS HCS 2.0 JUMPER CABLE 5 ?;"5;7" SCALE: E N� HCS 2.0 PENDANT 4 a N 0 0 N 22.9" PLAN VIEW 3.0" FRONT VIEW HEAT EXCHANGER ANGER HEAT XCHANGER MANUFACTURER: CHARES MODEL: CUBE RL1003AB—A WEIGHT: 260 LBS DIMENSIONS: 22.9"x 2 6.3"x 2 0. O" INSTALL PER MFR SPECIFICATIONS 20.0" RIGHT VIEW MANUFACTURER: RAYCAP MODEL' — WEIGHT: 21.9 LBS DIMENSIONS: 14.0"x 16.0"x8.0" NOTE: MOUNTING KIT BY MFR 14.0" 8.0" o FRONT VIEW RIGHT VIEW TMCIIIIII, s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#CONSUL"TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonhemhfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: A-4 24"x36" SCALE: NTS 11"07" SCALE: NTS AAV CUBE 13 111 x17" SSE: NNTS NOT USED 12 124:x3:: SCALE: NTS 11 x17" SCALE: NTS HCS 2.0 JUNCTION BOX 11 MANUFACTURER: PURCELL SYSTEMS INC MODEL: HPL3600A DC CABINET WEIGHT: 430 LBS (WITHOUT EQUIPMENT) DIMENSIONS : 30.0"x4 8.0"x 72.0" NOTE: • ADDITIONAL KNOCKOUTS MAY BE REQUIRED AND CAN BE DRILLED ON SITE AS NECESSARY. FOR CABINETS STARTING AT 501 THERE WILL BE A TOTAL OF (8) KNOCKOUTS (2) HORIZONTAL ROWS OF (4) RACK ASSIGNMENT RACK RU SLOT DESCRIPTION a 0 15 3RD AIRSCALE 14 13 12 FIBER MUX 11 10 2ND AIRSCALE 9 8 7 FIBER MUX 6 5 1ST AIRSCALE 4 3 2 FIBER MUX 1 RECTIFIER SHELF 0 m 16 AAV 15 CSR 14 13 4TH AIRSCALE 12 11 10 FIBER MUX 9 3RD LEGACY BBU 8 7 6 2ND LEGACY BBU 5 4 3 1ST LEGACY BBU 2 1 N N r ISO VIEW FRONT VIEW 4X .875 0 HOLES FOR HPL3 AND EXPANSION CABINET 2—STRING BATTERY RACK MOUNTING POINTS 4X .875 0 HOLES FOR HPL3 4—STRING BATTERY RACK MOUNTING POINT SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS; DO NOT DRILL KNOCKOUTS THROUGH SKU# 34038 PURCELL 2" PLINTH (OPTIONAL) FIBER ROUTE OPTION 1:— IT IS STRONGLY RECOMMENDED TO USE THESE (4) KNOCKOUTS TO & FROM COVP WITH WATER —TIGHT LB OR GROMMET lu 30" °� 6 ° ° N O O SKU# 34038 PURCELL 2" PLINTH PLAN VIEW an" PLAN VIEW $„ 32„ 8„ ❑ I OO 000 OO 000 O 01 oo 000 SS 0 0 0 RIGHT VIEW -(6) KNOCKOUTS LOCATED INCONVENIENTLY FROM INTERNAL AIRSCALE EQUIPMENT & ARE NOT FEASIBLE. SEE FIBER ROUTE OPTION 1. -KNOCKOUT FOR ETHERNET FOR ALARMS -KNOCKOUTS FOR BATTERY WIRES 4X .75 0 HOLES FOR HPL3 AND EXPANSION CABINET CORNER MOUNTING POINTS ALL DC POWER CABLES (BLUE) TO BE ROUTED AT THE LEFT SIDE OF THE CABINET SKU# 34038 PURCELL 2" PLINTH SIDE VIEW tea" (4x) o/ BATTERY M (4x) 5/ CABINET AN( d I n MOUNTING FOOTPRINT AIRS, BASEE FIBER ROUTE OPTION 2: REAR KNOCKOUTS CAN BE UTILIZED FOR BOTTOM FIBER ROUTING FROM COVP TO AIRSCALE IF OPTION 1 IS UNAVAILABLE. ALPHA (48 BREAKER (3) 2- KNOCKOUTS INTENDED FOR POWER, TELCO, & BOTTOM FIBERS TO COVP; ALL INCOMING CABLING TO BE IN RIGID OR FLEXIBLE CONDUIT WITH AN LB .1 ANY OF THE BOTTOM KNOCKOUTS CAN BE USED FOR THE AC POWER FEED BACK VIEW CSR F INTERNAL ROUTING FRONT VIEW (OPEN) FIBER KNOCKOUT FIBER CABLES (YELLOW) 19" RACK ADAPTER ALL FIBER CABLES (YELLOW) TO BE ROUTED AT THE RIGHT SIDE OF THE CABINET FIBER MUX/ DEMUX RECTIFIERS (10 POSITIONS) AIRSCALE BASEBAND LEGACY BASEBAND T Mok.P__% 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL•TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: A-5 24"x36" SCALE: NTS 11"x17" SCALE: NTS PURCELL HPL3 600A DC POWER CABINET SPECIFICATIONS 1 1 JAUFA TURER: PUR ELL V TEM IN EL: HPL3 LARGE BATTERY CABINET GHT:350LBS (WITHOUT EQUIPMENT) N S I O N S: 30.0"x31.6"x60.4" NOTE: • WIRES RUN THROUGH PROVIDED KNOCKOUT. FOLLOW PROPER INSTALLATION OF GASKET BEFORE MATING THE 2 CABINETS 4X .875 0 HOLES FOR HPL3 AND EXPANSION CABINET 2—STRING BATTERY RACK MOUNTING POINTS 4X .875 0 HOLES FOR HPL3 4—STRING BATTERY RACK MOUNTING POINT SKU# 34038 PURCELL 2" PLINTH PLAN VIEW 4X .75 0 HOLES FOR HPL3 AND EXPANSION CABINET CORNER MOUNTING POINTS SKU# 34038 PURCELL 2" PLINTH SIDE VIEW 0 m N KNOCKOUT F ETHERNET F ALAS KNOCKOUTS FOR BATTERY WIRES SHIPPING HOOKS TO BE REMOVED AFTER CABINET INSTALL ORRECT KNOCKOUT TOOL EQUIRED FOR PUNCHING NOCKOUTS. DO NOT DRILL NOCKOUTS THROUGH .,4038 PURCELL 2" PLINTH (OPTIONAL) BATTERY BRACKETS BATTERY VIBRATION MOUNTS 30" 11 T .MOB, s FOR CABINET 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#CONSUL.TMWG BATTERY ELVES, UP TO DAH PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonhemhfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: A-6 24"x36" SCALE: NTS 11"x17" SCALE: NTS PURCELL HPL3 LARGE BATTERY CABINET SPECIFICATIONS 1 1 MANUFACTURER: NOKIA MODEL: ASIB MODULE DIMENSIONS: 8.6"04.2%1.7" WEIGHT: 6.4 LBS ••••• ii�ii�:LJ LJ LJ°�. �°5 ..................... �� l ::®:: �T ee iii PROPOSED ASS LOCATED WITHIN AMIA RACK MANUFACTURER: NOKIA MODEL: ABIA MODULE DIMENSIONS: 8.6"x14.2"x1.1 " WEIGHT: 4.6 LBS re C�....... �....•�....... ...... — ....� NMEN • ..• • :::::..•:•�::•. .. —.. C•1 -- LJ L-J�-r L31 Llo�,f@ :7 7 ` PROPOSED ABIA LOCATED WITHIN AMIA RACK MANUFACTURER: NOKIA MODEL: ABIL MODULE DIMENSIONS: 8.6"04.2"0.1 " WEIGHT: 4.4 LBS SFP28 S-RF1 S-RF2 @ ... O. o' 0000000000000000 00 0 0000000800000000 0 0 00 0 S-RF1 S-RF2 QSFP28 �ravila••• PROPOSED ABIL LOCATED J WITHIN AMIA RACK I ?"x7" (� 24"x36" SCALE: NITS F 24"x36 SCALE: NITS 1 1SCALE: NTS AS I B 6 11 "x17" SCALE: NTS ABIA cJ 11 "x17" SCALE: NITS ABIL 141 MANUFACTURER: NOKIA MODEL: ABIC MODULE DIMENSIONS: 8.6"x14.2"x1.7" WEIGHT: 5.8 LBS RF2 RF4 RF6 RF8 000000o 0 0000 RF1 RF3 RF5 j j ®� ©� moo, _I r MANUFACTURER: NOKIA MODEL: ASIK MODULE DIMENSIONS: 8.6"x14.2"x1., WEIGHT: 6.6 LBS ••..I.I.UI.UI.Ui<,. 1111�q.10 I.i �Illi. .i lli. .i .I.i�.�.�.. �—•oo�.i�aii�iiiii �Y ..i i9 ------------- _ • ii.(ii i(ii i.i••.i i•'e�e PROPOSED ASK LOCATED — WITHIN AMIA RACK T .Moll -al s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEAT TLE, WA98101 Tel: 206.268.7370 W W W.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. PROPOSED ABIL LOCATED J WITHIN AMIA RACK I ?"x7" (� 24"x36" SCALE: NITS F 24"x36 SCALE: NITS 1 1SCALE: NTS AS I B 6 11 "x17" SCALE: NTS ABIA cJ 11 "x17" SCALE: NITS ABIL 141 MANUFACTURER: NOKIA MODEL: ABIC MODULE DIMENSIONS: 8.6"x14.2"x1.7" WEIGHT: 5.8 LBS RF2 RF4 RF6 RF8 000000o 0 0000 RF1 RF3 RF5 j j ®� ©� moo, _I r MANUFACTURER: NOKIA MODEL: ASIK MODULE DIMENSIONS: 8.6"x14.2"x1., WEIGHT: 6.6 LBS ••..I.I.UI.UI.Ui<,. 1111�q.10 I.i �Illi. .i lli. .i .I.i�.�.�.. �—•oo�.i�aii�iiiii �Y ..i i9 ------------- _ • ii.(ii i(ii i.i••.i i•'e�e PROPOSED ASK LOCATED — WITHIN AMIA RACK T .Moll -al s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEAT TLE, WA98101 Tel: 206.268.7370 W W W.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: A-7 24"x36" SCALE: NTS 11"x17" SCALE: NTS ABI 3 24"x36" SCALE: NTS l� 11"x17" SCALE: NTS NOT USED 1 2 1 11"x17= SCALE: Nn ASK 1 1 MANUFACTURER: NOKIA MODEL: AMIA DIMENSIONS: 5.1 "X15.7"X17.6" WEIGHT: 11.2 LBS MANUFACTURER: NOKIA MODEL: FSMF MODULE 176" DIMENSIONS: 5.2"x17.6"06.5" WEIGHT: 25.3 LBS NOTE: FSMF SHALL BE PLACED WITHIN RADIO CABINET PER T-MOBILE REQUIREMENTS N SIDE TOP \.Ie IimI III III III I1�1 iul III III I1�1 II�III�I i�■rlllllllll�a `fie I �I Il�lll�lll�lll�lll��ea Igmi I6II�III�III�III�I�� OPTIONAL POWER DISTRIBUTION OPTIONAL CAPACITY OPTIONAL TRANSPORT SUB -MODULE EXTENSION SUB -MODULE SUB -MODULE MANUFACTURER: NOKIA MODEL: IXR-E MODULE DIMENSIONS: 17.25"00.0"x 1.75" WEIGHT: TBD MMww1•�rw w�wrw w��rw ® www 1111.110-m! 7�J�] Cn] � `''�77T Kill I ?"x7" 24"x36" SCALE: NITS F 24x36 SCALE: NITS 1 1SCALE: NITS A M I A 6 11 "x17" SCALE: NITS FSMF cJ 11 "x 17" SCALE: NITS IXR- E 141 T Mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: CONSTRUCTION DETAILS SHEET NUMBER: 8 24"x36" SCALE: NTS NOT USED 3 24 x36" SCALE: NTS 11"x17" SCALE: NTS 11"x17" SCALE: NTS NOT USED 1 2 1 11"x17= SCALE: Nn NOT USED 1 1 EXISTING ANTENNA AND COAX SCHEDULE REDS ANCHOR VERSION 5, DATED 08/31/2020 1:12:22 PM SECTOR ALPHA AZIMUTH RAD CENTER NUMBER OF VENDOR MODEL ELEC MECH NUMBER OF FEEDER FEEDER ADDITIONAL EQUIPMENT ANTENNAS TILT DOWNTILT FEEDERS TYPE LENGTH Al 0' 87'-6" 1 COMMSCOPE SBNHH-1D65C-SR (HEX) 4 0' 1 NOS 1.0 125't (1) FRLB (4) DIPLEXERS (1) COVP (2) FXFB (1) FRIJ A2 - - - - - - - A3 _ _ _ _ _ _ _ SECTOR BETA AZIMUTH RAO CENTER NUMBER OF ANTENNAS VENDOR MODEL ELEC TILT MECH DOWNTILT NUMBER OF FEEDERS FEEDER FEEDER TYPE LENGTH ADDITIONAL EQUIPMENT B7 120' 87'-6" 1 COMMSCOPE SBNHH-1D65C-SR (HEX) 4 0' - - - (1) FRLB (4) DIPLEXERS (1) FRIJ 82 - - - - - - - B3 - - - - - - - B4 SECTOR GAMMA AZIMUTH RAD CENTER NUMBER OF VENDOR MODEL ELEC MECH NUMBER OF FEEDER FEEDER ADDITIONAL EQUIPMENT ANTENNAS TILT DOWNTILT FEEDERS TYPE LENGTH C1 240' 87'-6" 1 COMMSCOPE SBNHH-1D65C-SR (HEX) 4 0' - - - (4) DIPLEXERS (1) FRLB (1) FRIJ C2 - - - - - - - - C3 - - - - - - C4 EXISTING 91'-6" STEEL LIGHT POLE EXISTING T-MOBILE FRLB RADIO (TYP OF 3, 1 PER SECTOR) TO BE REMOVED A4 EXISTING T-MOBILE PANEL ANTENNA [ANDREW SBNHH-1D65C-SR (HEX)] TO BE REMOVED EXISTING T-MOBILE DIPLEXER (TYR OF 12, 4 PER SECTOR) (6) TO BE REMOVED AND (6) TO BE RELOCATED TO GRADE LEVEL GPI rLkG EXISTING T-MOBILE FRIJ RADIO (TYP OF 3, 1 PER SECTOR) TO BE REMOVED PROPOSED ANTENNA AND COAX SCHEDULE REDS ANCHOR VERSION 5, DATED 08/31/2020 1:12:22 PM SECTOR ALPHA AZIMUTH RAD CENTER NUMBER OF ANTENNAS VENDOR MODEL ELEC TILT MECH DOWNTILT NUMBER OF FEEDERS FEEDER TYPE FEEDER LENGTH ADDITIONAL EQUIPMENT Al 0' 87'-6" 1 COMMSCOPE FFW-65C-R3-V1 (OCTO) - - *2 2 HCS 2.0 7/8" COAX 150'f 145't (1) AHLOA (1) AHFIG (1) STYLE 3CX TMA A2 0' 87'-6" 1 ANDREW HBXX-6517DS-A2M (QUAD) - - A3 0' 87'-6" 1 NOKIA AEHC ACTIVE ANTENNA/RADIO - - A4 SECTOR BETA AZIMUTH RAD CENTER NUMBER OF ANTENNAS VENDOR MODEL TILT MECH DOWNTILT NUMBER OF FEEDERS FEEDER TYPE FER FEEDER LENGTH ADDITIONAL EQUIPMENT B1 120' 87'-6" 1 COMMSCOPE FFW-65C-R3-V1 (OCTO) - - 2 7/8" COAX 145'f (1) AHLOA (1) AHFIG (1) STYLE 3CX TMA B2 120' 87'-6" 1 ANDREW HBXX-6517DS-A2M (QUAD) - - B3 120' 87'-6" 1 NOKIA AEHC ACTIVE ANTENNA/RADIO - - B4 _ SECTOR GAMMA AZIMUTH RAD CENTER NUMBER OF ANTENNAS VENDOR MODEL ELEC TILT MECH DOWNTILT NUMBER OF FEEDERS FEEDER TYPE FEEDER LENGTHADDITIONAL EQUIPMENT C1 240' 87'-6" 1 COMMSCOPE FFW-65C-R3-V1 (OCTO) - - 2 7/8" COAX 145'f (1) AHLOA (1) AHFIG (1) STYLE 3CX TMA C2 240' 87'-6" 1 ANDREW HBXX-6517DS-A2M (QUAD) - - C3 240' 87'-6" 1 NOKIA AEHC ACTIVE ANTENNA/RADIO - - C4 _ _ _ _ _ _ _ NOTES: -PROVIDE VOLTAGE BOOSTER FOR LTE 1. ALL PROPOSED EQUIPMENT IS LOW VOLTAGE, DC POWER 2. COORDINATE WITH CONSTRUCTION MANAGER FOR CURRENT REDS PRIOR TO CONSTRUCTION 3. CABLE LENGTH IS APPROXIMATE. CONTRACTOR TO FIELD VERIFY CABLE LENGTHS PRIOR TO ORDERING, FABRICATION, OR INSTALLATION OF CABLES. 4. NO WORK SHALL COMMENCE WITHOUT THE APPROVED TOWER/ANTENNA MOUNT STRUCTURAL ANALYSIS REPORT (SIGNED AND SEALED) PROVIDED UNDER SEPARATE COVER. CONTRACTOR PRIOR TO INSTALLATION OF ANTENNAS, EQUIPMENT AND COAX CABLES SHALL REVIEW THE APPROVED TOWER STRUCTURAL ANALYSIS PROVIDED BY T-MOBILE AND MODIFY, IF REQUIRED, ALL APPLICABLE MEMBERS AS INDICATED IN THE CERTIFIED STRUCTURAL. 1 I N N PROPOSED T-MOBILE PANEL ANTENNA 2 EXISTING T-MOBILE FXFB RADIO [ANDREW HBXX-6517DS-A2M (QUAD)] A-3 EXISTING COVP TO BE RELOCATED TO GRADE LEVEL TO BE REMOVED e PROPOSED T-MOBILE AEHC o EXISTING T-MOBACTIVE ANTENNA/RADIO ILE FXFB RADIO PROPOSED T-MOBILE PANEL ANTENNA 3 aA_3 < o a N TO BE REMOVED EXISTING T-MOBILE PANEL ANTENNA a II [COMMSCOPE FEW-65C-R3-V7 (OCTO)] A-3 a 4 [ANDREW SBNHH-1D65C-SR (HEX)] TO BE REMOVED EXISTING 91'-6" Al STEEL LIGHT POLE A3 Al A2 A2 PROPOSED T-MOBILE AHLOA g (' MOUNTED BEHIND ANTENNA A3 PROPOSED T-MOBILE STYLE 3CX TMA A4 (TYP OF 3, 1 PER SECTOR) A-3 (TYP OF 3, 1 PER SECTOR) I IF FA IF 11 A-3 II I I I I B4 C1 B4 Ll.-1 EXISTING VACANT PIPE (TYR) PROPOSED T-MOBILE PANEL ANTENNA EXI[COMMSCOPE FFW-65C-R3-Vl (OCTO)] EXISTING T-ARM MOUNT (TYP) TOSREMAIN TING ARM MOUNT (TYP) e B3 A-3 CC22/ 83 2 PROPOSED T-MOBILE PANEL ANTENNA)/ A-3 [ANDREW HBXX-6517DS-A2M (QUAD)] PROPOSED T-MOBILE ACTIVE ANTENNA/RADIO AEHC A43 C3 V % B2 2�. C3 � 82 q2��q 72p• eA-34 PROPOSED T-MOBILE AEHC ACTIVE ANTENNA/RADIO PROPOSED T-MOBILE PANEL ANTENNA C4 C4 2 81 [ANDREW HBXX-6517DS-A2M (QUAD)] A-3 /B1 PROPOSED T-MOBILE AHFIG 5 MOUNTED BEHIND ANTENNA EXISTING VACANT PIPE (TYP) (TYP OF 3, 1 PER SECTOR) A-3 EXISTING T-MOBILE PANEL ANTENNA [ANDREW SBNHH-lD65C-SR (HEX)] PROPOSED T-MOBILE PANEL ANTENNA 3 TO BE REMOVED [COMMSCOPE FFW-65C-R3-V1 (OCTO)] A-3 T .Mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirslhfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T-MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: ANTENNA CONFIGURATION SHEET NUMBER: RF-1 24"x36" SCALE: 3/4" = 1'-0" 11"07" SCALE: 3/8" = 1'-0" 1' 6" 0" 1 EXISTING ANTENNA LAYOUT 1 2 1 11�07" SALE: 1/4" = 2' 1, 0. 2' PROPOSED ANTENNA LAYOUT 11 Configuration 56791EZ_1-1121 ' For 5G and LTE Airscale BB dimensioning refer to Fiber Port matrices. (Alpha, Beta & Gamma) AEHC LTE+5G �1 119t119 L21+AM3 AHFIG AWS+PCS L700 ■ r4boo U21 AHLOA 700*600 HCS1.0 Top Ground 1.0 HCS1.0 T~rTop 50 Airscale FDD - Lowband B12 (1-700) - 5 MHz B71 (1-600) -10 MHz B71 (N600) - 10 MHz FDD - Midband 64 (L2100) -- 20 MHz 62 (L1900) - 20 MHz B25 (1-1900) - 20 MHz 666 (AW53) - 5MHz TDD -Band 41 L2.5(2.5GHz)- 60 MHz N41(2.SGHz)- 100MHz +2nd carrier (c=80MHz) FXFB FRIE E S h18 I UMTS r�5M } AWS LTE FDD/MD Airscale1 T .M0_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: I rM MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhemhfield.00m MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: PLUMBING DIAGRAM SHEET NUMBER: RF-2 24"x36" SCALE: NTS 11"07" SCALE: NTS PLUMBING DIAGRAM 1 1 NOKIA ITEM CODE/SECTOR PRODUCT NAME 474335A FOCZ QSFP+ 400 km SM 474385A FOUF SFP+ 1OGBASE—LR 1271 nm CWDM 10 km SM 474386A FOUG SFP+ 1OGBASE—LR 1291 nm CWDM 10 km SM 474387A FOUH SFP+ 1OGBASE—LR 1311 nm CWDM 10 km SM 474388A FOUI SFP+ 1OGBASE—LR 1331 nm CWDM 10 km SM 474829A AOSB QSFP28 SM 10 km LC FTLX1370W4BTL SM SFP 1310 nm CPRI 9.8G 1.4km (CPRI) 473471A MAFOTA Optical SFP+ 1OGBase—SR 850nm MM FTLXB573D3BTL 1OGb/s 850nm Multimode SFP+ Datacom Transceiver NOTE: JDSU AND EXFO GEAR CAN BE USED TO READ WAVELENGTH ON THE SFPs. -PORT CONNECTION ON THE ARIA MAY VARY AND ARE DESIGNATED AS RFx ('x' CAN BE 1-6) "AHFIB/AHFIG IS ON SAME ABIA IXR—e ...._. NR LTF ARIL ASIK T mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .rrorrisonhershfield.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: TYPICAL SECTOR SFP SHEET NUMBER: RF-3 24"x36" SCALE: NTS 11"07" SCALE: NTS TYPICAL SECTOR SFP 1 1 GROUNDING KEYNOTES OEXISTING EQUIPMENT GROUND RING. VERIFY IN FIELD. 2 BOND EQUIPMENT CABINET ENCLOSURE USING A MANUF. APPROVED CONNECTION WITH (2) #2 AWG SOLID BARE TINNED COPPER CONDUCTORS AND EXOTHERMICALLY WELD TO GROUND RING. O#2 AWG SOLID BARE TINNED COPPER CONDUCTORS BONDING RADIO/JUNCTION BOX TO GROUND RING. EXISTING T—MOBILE 100A METER UPGRADED AS REQUIRED PER ELECTRICAL UPGRADE SCOPE OF WORK PROPOSED 200A EMERSON PPC; SEE POWER UPGRADE NOTE POWER UPGRADE NOTE: EXISTING 100A AC SERVICE IS TO BE UPGRADED TO 200A PER SEPARATE ELECTRICAL SERVICE UPGRADE SCOPE OF WORK/DESIGN, UNDER SEPARATE ELECTRICAL PERMIT AS REQUIRED, TO BE INCLUDED IN NTP PROPOSED (2) PROPOSED (1) 3" RIGID CONDUIT 3" RIGID CONDUIT TO EACH JUNCTION BOX (TYP) 3 TYP JCUIE ---- -- -----� r I� P � I i 1 so__n I EXISTING T—MOBILE 100A DISCONNECT UPGRADED AS REQUIRED PER ELECTRICAL UPGRADE SCOPE OF WORK PROPOSED CAMLOC _ HPL3 HPI0 I / 600A DC BATTERY CABINET. CABINET � I � � I I T-MoUk. 19807 NORTH CREEK PKWY N N BOTHELL, WA 98011 1 1 RYKA#CON,SULTMWG LEGEND Tr GROUND BAR EXOTHERMIC CONNECTION ❑ MECHANICAL CONNECTION 1 GROUND PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: EQUIPMENT ELECTRICAL/ GROUNDING PLAN SHEET NUMBER: E-1 24"x36" SCALE: NTS 11"07" SCALE: NTS NOT USED 12 111 x17" SSE: NTS EQUIPMENT ELECTRICAL/GROUNDING PLAN 1 1 RED DOOR ALARM SWITCH DOOR ALARM BLK • DAC ALARM 1 SYirJi ® HEATER ALARM J8 J9 V7 d JB J3 DAC ALARM c n DC POWER ALARM 11 Q 1 HEA1}}T�}} FM1JJ8 J3 J274 ®® ® • HEATER HEATER DOOR OPEN DETECT SWITCH CODEX ALARM MODULE INSIDE FRONT DISTRIBUTION COVER DC ALARM WIRING GRN ALARM CABLE 1 WHT LU WHT ORG GR BL OR T (BROWN PAIR O00 O 00� NOT USED) 70 71 73 74 76 77 9 K 9 K 10 K 11 DC ALM ALARM AL3 DC MIN AL3 RTN AL4 DC MAJ AL4 RTN AC MAINS HI AILS LOW AL5 RTN 1 DOOR ALM L1 BLK L2 RED VDAC ALM D 3&4 L1 BLK SHELF 1 RED L2 L2 RED GRN V LE]GRN HTR ALM a BLK MDL 5 L2 RED V L1 BLK SHELF 2 BLK L1 DC ALM M L 3&4 L2 RED RED Lz V c I GRN GRN DC MAL V DCPP REAR VIEW AC PWR HULOW AC POWER CONNECTIONS V BAT CAB DOOR V BAT CAB DAC v BAT CAB CBALM V 10 V 11 V ' rr UPPER LEVE TERMINALS I 12 LOWER LEVEL V TERMINALS I CABINET BATTERY EXPANSION TO HEATER RELAY HEATER HEATER OPT CABINET IFF�I FR IFNI IFNI IFNI IFNI 0000 0000 0000 00©• BLACK RED O ,0 OL20 FIELD WIRING 240VAC SINGLE PHASE 60Hz 200A MAX ON ON ON ON ON ON 0 0 0 0 0 0 1 1 A 1 A BLK BLK BLY 3 240VAC DINRAIL ASSEMBLY GREEN WIRES TOCAB MGB 121"x17 SCALE: NTS ALARM WIRING DIAGRAM 1 4 1 11 x17= Ste: � AC POWER WIRING DIAGRAM 1 3 I EMERSON 120/208V, SINGLE PHASE 200 AMP MAIN BREAKER W/ TVSS 65,000 AIC RATING CIRCUIT DESCRIPTION im A B KVA CIRCUIT DESCRIPTION 200 20 HPL3 SITE SUPPORT CABINET 12 1 2 ^ 0.19 RECEPTACLE & LIGHT 4 i ��- 5 6 8 0 �� 11 2 i� n 14 �— _ 15 e 1] 18 ^ LOAD CALCS (8) 3KW RECTIFIERS= 24KVA RECEPTACLE & UGHT= 0.19KVA TOTAL 24.19 KVA 116 AMPS (3) #3/0 THWN IN 2" U.G. CONDUIT 2-1/2" U.G. PVC CONDUIT FROM UTILITY EMERSON 'CAC' MODEL: GENERATOR RECEPTACLE 200A, 120/208V, 10, 3W WITHIN POWER CABINET u _ _ _ _WALKING BEAM INTERLOCK y200/2 y20/1 TRANSITION TO ABOVE GRADE I GROUND PER NEC SPACES (2) #/0 CU SUPER FLRX 200/2 & (1) #4 GRN GIRD IN HPL3 SITE 2" RIGID CONDUIT SUPPORT CABINET I I I I 20/1 L GFCI RECEPTACLE/LIGHT NOTE: DIAGRAMS PROVIDED ARE PER MANUFACTURER INSTALLATION GUIDE DC DISTRIBUTION —DOOR OPEN FROM VIEW "TIER"1 "TIER"2 'TIER"3 'TIER"4 THERMAL SYSTEM IP °�` THERMAL SYSTEM IP °A DAC AND HEATER IP ° ° dl DAC AND HEATER IP FUTURE USE o vD O O ° FUTURE USE o FUTURE USE IP O O O ° FUTURE USE IP O O O ° FUTURE USE O O o FUTURE USE OauO o OO o (Do (0 0 00 ° OO o (Do OO o OO ° OO o (0. (0 o OO ° Oa o (Do OO o (Do O O OO ° O O O° O O OO ° O ®O O° 0 ®O 0° O ®O O° O ®O O° JUMPER I I ,JUMPER JUMPER I I i I i , ° CB ^AMAR 1 ° E CBAMARM HPIN AND SWITCH N AND SWITCH ORIENTATION ORIENTATION 'OFF' ° ° CB AMARM PIN AND SWITCH ORIENTATION OBSERVE CORRECT ALARM PIN ORIENTATION CB AMARM "OFF' DC DISTRIBUTION TERMINALS "TIER"1 OF 4(SIDE VIEW) BLK i RED TO CABINET DC FUSE BLOCK 1 DAC DOOR PWR 25A Ill FUTURE USE 1DA 11111= 0 0 0 0 1 Op p p 0 FUTURE USE 1DA O= p000 0QO FUTURE USE 1DA OF_--] 00 00 O QO �0 00 FRONT oOOO Op OO 00 00 00 00 �0 0� 1200 12 '40 DC-48V HOT BUS DC RETURN (CB FROTECTED) BUS OV(+) REAR T mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.com MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: DIAGRAMS SHEET NUMBER: E-2 NNW SCALE: NITS 11"0 7" SCALE: NTS NOT USED 12 121 "x36" SCALE: NTS DC POWER WIRING DIAGRAM 11 FROM DC DIN DISTRIBUTION U�U J1 Oo TO CABINET COOL ALARM BLOCK U"U � J8 J9 RE J8 J3 J2 J4 O ®4 �'j �jQ�O HEATER J9 ALARM FROM J7 DAC DOOR JB ALARM FROM DC DIN DISTRIBUTION O J, SW, HEAT JB J9 J7 J3 J2 J4 DOOR OPEN FROM DETECT DOOR TO HEATER ELEMENT AC PWR FROM CIRCUIT BREAKER NNW SCALE: NTS 11"07" SCALE: NTS RED o o BLACK O O BLACK RED BLACK RED DAC (COOLING) CONTROLLER COHN FUNCTION JI PIWR IN J8 DELTA T JUMPER J9 OUTSIDE TEMPETATURE J7 DACFAN (LOWER) J6 DACFAN (UPPER) J3 ALARM J2 COOLING INHBIT J4 HEAT REQUEST HEATER CONTROLLER COHN FUNCTION JI PIWR IN J8 HEAT REQUEST J9 COOLING INHBIT J7 UNUSED J6 HEATER FAN J3 ALARM J2 DOOR SW INPUT J4 HEATER REALY CONTROL FROM DIN DISTRIBUTION DOOR OPEN DETECT I111"x17" SCALE: NTS DC CABINET DOOR LIGHT POWER WIRING DIAGRAM 13 TO DOOR V+ UPPER FAN V_ TO DOOR V+ LOWER FAN V_ SCALE: NTS DC HEATING AND COOLING WIRING DIAGRAM 12 1 1107" SCALE: NTS _ED LIGHT T mo_a s 198117 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W W W.morrisonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A FROM DC PLANT 25A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 DC DISTRIBUTION (BLACK WIRE JUMPERS TO SHEET NAME: FUSE POSOTIONS REMOVED FOR CLARITY) DIAGRAMS SHEET NUMBER: E-3 DC FUSE BLOCK WIRING DIAGRAM 11 [e omaINI\[H3aa\Nll3. TYP Oi NOT USED. ONOT USED. OEXISTING AGE AT ANTENNA LEVEL. VERIFY ANTENNA CABLE GROUNDING KITS ARE BONDED TO GROUND BAR. O4 NOT USED. OPROPOSED T—MOBILE ANTENNA AND RADIOS PER PLAN. OEXISTING GROUNDING CONDUCTOR BONDED TO ANTENNA PIPE MOUNT. OBOND PROPOSED RADIO UNIT TO AGE WITH #2 AWG STRANDED GREEN JACKET COPPER CONDUCTOR I GROUNDING NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE CADWELD AND CLEANED THOROUGHLY THEN COVERED WITH TWO (2) COATS OF SERWIN WILLIAMS GALVANTE PAINT B350W3 OR EQUAL. SEE 4. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND. 5. ALL ELECTRICAL CADWELD AND MECHANICAL CONNECTIONS SHALL HAVE NON —OXIDATION COMPOUND APPLIED TO CONNECTION. 6. ALL MATERIALS AND CADWELD MOLDS, SHOTS, ETC. SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR UNLESS OTHERWISE NOTED. 7. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 8. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. 9. USE PANI SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN NSTD 119, 33 & 36. LEGEND rr GROUND BAR O EXOTHERMIC CONNECTION E7 MECHANICAL CONNECTION 1 GROUND NOTES: 1. BOND EQUIPMENT TO GROUND BAR(S) PER MANUFACTURER SPECS 2. CONTRACTOR TO REPLACE ALL MISSING GROUND BAR AND GROUNDING CONNECTIONS AS REQUIRED T .Mo_a s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 v .morrlsonhershfield.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: ANTENNA GROUNDING SCHEMATIC SHEET NUMBER: E-4 24"x36" SCALE: NTS 11"07" SCALE: NTS ANTENNA GROUNDING SCHEMATIC 1 1 NOTES: 1. COAT ALL MECHANICAL CONNECTIONS WITH "NO—OX" OR APPROVED EQUAL 2. ALL EXISTING & NEW TOWER GROUNDING BARS SHALL BE ATTACHED DIRECTLY TO THE TOWER WITHOUT ISOLATORS; NO WELDING OR DRILLING PERMITTED 3. EXISTING HOME RUN GROUND(S) TO BE REMOVED NEW COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION DOUBLE LUGS, ATTACH TO GROUND BAR & INSTALL BY ANTENNA CONTRACTOR (CADWELD TYPE—GL) NEW 1/4" THK COPPER GROUND BAR, INSTALLED BY GENERAL CONTRACTOR r ___1 O 0 0 0 0 0 0 0 0 0 0 0 0 O O O O 000 O O O 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 O O O O O O O O 20" MGB OR 10" ANTENNA AGB FIELD VERIFY #2 AWG SOLID BARE TINNED COPPER GROUND WIRE (TYPE GL) STRANDED CU WIRE WITH GREEN, 600V, THHN/THWN INSULATION. SIZE AS SPECIFIED COPPER GROUND BAR ON WALL. OR ONEANTENNA TOWER I I� PANI SCHEME SPECIFICATIONS: PRODUCER (P) CONNECTS TO WIRELESS EQUIPMENT CABINETS, CABLE ENTRANCE GROUND BAR (CEGB), MAIN DISTRIBUTION FRAME GROUND BAR (MDFB), AND STANDBY ENGINE G ENERATOR SET FRAME AND OTHER NOISE PRODUCING EQUIPMENT. ABSORBER (Al CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL OFFICE GROUND GRID, BUILDING STRUCTURAL GROUND, METALLIC WATER PIPE SYSTEM, ANTENNA SUPPORTING STRUCTURE GROUND SYSTEM, AND ELECTRICAL SERVICE ENTRANCE GROUND. NON —ISOLATED (N) CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE (IGZ) SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH CBN AND IBN EQUIPMENT ISOLATED (1) CONNECTS TO THE SINGLE POINT CONNECTION BAR (SPCB) FOR IBN EQUIPMENT ••UVUV UV• • i 0 l 0 0 0• TWO HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16X1/4" STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE `TWO HOLE LUG, TO BE USED WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 60OV, TO ANTENNA STRUCTURE, BUILDING RING GROUND OR MGB NOTE: *GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION N (TYPICALLY) \� 12" TO 24" a o 120" MAX. ANTENNA CABLE"GROUND CABLE CONNECTOR WEATHERPROOFING KIT (SEE NOTE 3)STRANDED COPPER WIRE (GROUNDED TO CABLE GROUND KIT BAR). SEE NOTE 1 & 2 NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. 1 1 1111"x7" SCALE: NITS GROUND BAR 6 11"x17" SCALE: NTS x36" SCALE: NITS 1 GRND CABLE CONNECTION cJ "x17" SCALE: NITS COAX CABLE GROUNDING 141 TO ANTENNAS COAX JUMPER (TYP) CONNECTOR WEATHERPROOFING KIT (TYP) SEE NOTE 2 ANTENNA CABLE TO BTS EQUIPMENT (TYP) VEATHERPROOFING :IT (TYP) ROUND KIT (TYP) 16 AWG TOPPER ANTENNA GROUND AIR, ATTACHED DIRECTLY TO OWER WITHOUT ISOLATOR. 10 WELDING OR DRILLING 'ERMITTED. TO GROUND RING NOTES: DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. WEATHER PROOFING SHALL BE TWO—PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. T Molk s 19807 NORTH CREEK PKWY N BOTHELL, WA 98011 1 1 RYKA#OONSUL.TMWG PLANS PREPARED BY: mri MORRISON HERSHFIELD 600 STEWART STREET, SUITE 200 SEATTLE, WA 98101 Tel: 206.268.7370 W Ww.morrlsonheirshfielcl.mm MH PROJECT NUMBER: 202119200 REV. DATE ISSUED FOR BY A 09/10/20 90% REVIEW BA 0 09/21/20 100% FINAL BA SET NOT TO BE USED FOR CONSTRUCTION UNLESS SIGNED BY DESIGN PROFESSIONAL AND STAMPED APPROVED BY MUNICIPALITY SITE NAME: LAKOTA PARK T—MOBILE SITE I.D. SE04653A SITE ADDRESS: 31334 SW DASH POINT RD FEDERAL WAY, WA 98023 SHEET NAME: GROUNDING DETAILS SHEET NUMBER: E-5 24"x36" SCALE: NTS 11"07" SCALE: NITS GRND CABLE CONNECTION 13 1 SCALE, NTS 11 x37" SCALE: NITS NOT USED 1 2 1 11"x17- SCALE: Nn CADWELD 1 1