Loading...
20-104673-Planset-01-20-2021-V1TITLE SHEET T-1 REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2013 CBC BUILDING CODE. ACCESSIBILITY REQUIREMENTS: VICINITY MAP PROJECT SUMMARY CODE BLOCK SIGNATURE BLOCK APPROVAL SIGNATURE DATE SITE ACQUISITION MANAGER CONSTRUCTION MANAGER A&E MANAGER PLANNING CONSULTANT RF MANAGER PROPERTY OWNER AT&T REPRESENTATIVE AAV MANAGER MAP RF ENGINEER ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. NOT TO SCALE N NOT TO SCALE N Know what's below. CALL before you dig. CALL AT LEAST TWO WORKING DAYS BEFORE YOU DIG USA Nor t h DIG ALERT PROJECT TEAM CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING LOCATIONS, CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME DO NOT SCALE DRAWINGS SITE SITE SITE ACQ.PROJECT MANAGER: MASTEC NETWORK SOLUTIONS 22263 68th AVE S. KENT, WA 98032 VIET TRAN (206)310-1149 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL RESIDENTAL CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 NATIONAL ELECTRIC CODE CONSTRUCTION MANAGER: MASTEC NETWORK SOLUTIONS 22263 68th AVE S. KENT, WA 98032 MIKE SUTHERBY (253)579-3503 LEGAL DESCRIPTION PROJECT INFORMATION: ADRESS: SITE TYPE: FA#: PACE#: PTN#: PROJECT: 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 ROOFTOP 10102237 MRWOR046735 3801AT6ZH 5G NR SITE NUMBER: SITE NAME: SS81 WEYERHAEUSER T-1 TITLE SHEET NOTES & LEGEND OVERALL SITE PLAN EQUIPMENT LAYOUT T-2 A-1 A-2 A-3 A-6 A-7 G-1 G-2 GROUNDING PLANS GROUNDING DETAILS ENLARGED EQUIPMENT LAYOUT PROPOSED ANTENNA CONFIGURATION DETAILS SHEET DESCRIPTION DRIVING DIRECTIONS SHEET INDEX CONSULTING ENGINEER: SALAGA DESIGN 16212 BOTHELL-EVERETT HWY SUITE F304, MILL CREEK, WA 98012 VLAD DIACONU (216)375-2310 STRUCTURAL ENGINEER: MK ENGINEERING 12212 155 TH AVE SE RENTON, WA 98059 MIRO DOYTCHEV (425) 919-8452 SCOPE OF WORK RF-1 RF DETAILS PROPERTY OWNER:EAST CAMPUS 3 A/B LLC 82 DEVONSHIRE STREET, F3A BOSTON, MA 02109 LATITUDE:47,2969400° N LONGITUDE:-122,2897200° W JURISDICTION:CITY OF FEDERAL WAY ZONING DISTRICT:CPI - CORPORATE PARK EXISTING USE:UNMANNED TELECOMMUNICATIONS FACILITY PROPOSED USE:UNMANNED TELECOMMUNICATIONS FACILITY OCCUPANCY:B, S-2 A.P.N. 2154660020 DEPART FROM SEATTLE-TACOMA INTERNATIONAL AIRPORT: HEAD SOUTHEAST ON AIRPORT EXPRESSWAY TOWARD DEPARTURES DR, KEEP LEFT TO CONTINUE TOWARD ARRIVALS DR, CONTINUE ONTO ARRIVALS DR, SLIGHT RIGHT TO STAY ON ARRIVALS DR, TURN RIGHT ONTO INTERNATIONAL BLVD/PACIFIC HWY S, TURN LEFT ONTO S 200TH ST, USE THE MIDDLE LANE TO TAKE THE RAMP ONTO I-5 S, MERGE ONTO I-5 S, TAKE EXIT 142A TO MERGE ONTO WA-18 E TOWARD AUBURN, TAKE THE WEYERHAEUSER WAY S EXIT, TURN LEFT ONTO WEYERHAEUSER WAY S, TURN RIGHT AT THE 2ND CROSS STREET AT S 342 ST, TURN LEFT, DESTINATION WILL BE ON THE RIGHT 203 FT. A-5 EXISTING ANTENNA CONFIGURATION A-4 BUILDING ELEVATION EAST CAMPUS CORP PRK PRCL 3-BSP TGW UND INT IN TRACTS B,C & D PER FEDERAL WAY BLA #19-101124-00-SU REC # 20190624900005 ·REMOVING (3) KATHREIN 742-264 GSM ANTENNAS POSITION (4) ALPHA, BETA, GAMMA ·REMOVING EXISTING GSM COAX JUMPERS FORM POSITION (4) ALL SECTORS ·INSTALLING (3) COMMSCOPE NNHH-65B-R4 ANTENNAS POSITION (4) ALPHA, BETA, GAMMA ·INSTALLING (3) AIRSCALE RRH 4T4R B5 160W AHCA RRH'S MOUNTED BEHIND ANTENNAS IN SITE EXISTING PENTHOUSE STRUCTURE ·INSTALLING NEW COAX JUMPERS FROM PROPOSED RRH'S TO PROPOSED ANETNNAS AT EACH SECTOR ·INSTALLING NEW RET CABLES FOR PROPOSED ANTENNAS AT EACH SECTORS ·INSTALLING NEW DUAL FIBER JUMPERS FROM PROPOSED RRH'S TO EXISTING FC12'S ·INSTALLING NEW DC POWER JUMPERS FROM PROPOSED RRH'S TO EXISTING DC2'S ·INSTALLING (1) ASIK CARD IN C2 OF EXISTING FSM4 ·INSTALLING (1) ABIL CARD IN C2 OF EXISTING FSM4 ·INSTALLING (1) HEX DOOR ON EXISTING FLX16 CABINET FOR PROPOSED ASIK/ABIL CARDS INSTALLING (3) 25 AMP BREAKERS FOR PROPOSED RRH'S ·INSTALLING (2) RECTIFIERS IN EXISTING PP ·INSTALLING (1) DC CONVERTER MODULES IN EXISTING CONVERTER SHELF A-8 COMPLIANCE NOTES & LEGEND T-2 REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG GROUND ACCESS WELL CADWELD MECHANICAL GRND. CONN. GROUND ROD GROUND BUS BAR NEW ANTENNA EXISTING ANTENNA PLYWOOD GRAVEL EARTH (E) MASONRY CONCRETE GROUT OR PLASTER (E) BRICK EXPANSIONEXP. GROUND FAULT CIRCUIT INTERRUPTER GLOBAL POSITIONING SYSTEM G.F.I. GLB.(GLU-LAM) GPS GLUE LAMINATED BEAM F.S. FTG. G. GA. GI. FT.(') GALVANIZE(D) GAUGE FOOTING FOOT(FEET) FINISH SURFACE GROWTH (CABINET) FINISH(ED) FDN. F.O.W. F.O.C. F.O.M. F.O.S. FLR. FACE OF WALL FACE OF STUD FOUNDATION FLOOR FACE OF MASONRY FACE OF CONCRETE FAB. EXT. FIN. F.G. F.F. EXST.(E) FINISH FLOOR FINISH GRADE EXTERIOR FABRICATION(OR) EXISTING THK. TEMP. THICK(NESS) TEMPORARY ANTENNA CABLE COVER ASSEMBLY BARE TINNED COPPER WIRE ELECTRICAL METALLIC TUBING CLG.CEILING DIAGONALDIAG. ELECTRICALELEC. E.N. EMT. EQ. ENG. ELEV. EQUAL ENGINEER EDGE NAIL ELEVATOR DWG. DWL. DIM. EL. EA.EACH ELEVATION DOWEL(S) DRAWING(S) DIMENSION CONTINUOUSCONT. DBL. d D.F. DIA. DEPT.DEPARTMENT DOUGLAS FIR DIAMETER PENNY (NAILS) DOUBLE CLR. COL. CONC. CONN. CONST. CLEAR CONSTRUCTION COLUMN CONCRETE CONNECTION(OR) ARCHITECT(URAL) B/U CAB. C.I.P. CANT. B.O.F. BTCW. CABINET BOTTOM OF FOOTING CAST IN PLACE CANTILEVER(ED) BACK-UP CABINET BLK. B.N. BM. BLDG. BLKG. AWG. BEAM BLOCK BUILDING BLOCKING BOUNDARY NAILING AMERICAN WIRE GAUGE A.F.F.ABOVE FINISHED FLOOR ALT. ANT. APPRX. ARCH. ALUM. A.F.G. ALTERNATE ALUMINUM ANTENNA ABOVE FINISHED GRADE APPROXIMATE(LY) ABV. A.B. ADD'L ACCA ANCHOR BOLT ABOVE ADDITIONAL OPENINGOPNG. REFERENCEREF. SIMILARSIM. SQ. S.S. STL. STD. SPEC. STRUC. SQUARE STEEL SPECIFICATION(S) STANDARD STRUCTURAL STAINLESS STEEL RGS. SHT. SCH. REQ'D. REINF. SHEET REQUIRED SCHEDULE RIGID GALVANIZED STEEL REINFORCEMENT(ING) POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PERSONAL COMMUNICATION SERVICES POWER PROTECTION CABINET P.S.F. P.S.I. P.T. PWR. QTY. RAD.(R) QUANTITY RADIUS PRESSURE TREATED POWER (CABINET) PLY. P/C PCS PPC PRC PLYWOOD PRECAST CONCRETE PRIMARY RADIO CABINET LONG(ITUDINAL) (N) MTL. O.C. N.T.S. MISC. NO.(#) NEW METAL NUMBER ON CENTER MISCELLANEOUS NOT TO SCALE M.B. MAX. MIN. MFR. MAS. MECH. MAXIMUM MINIMUM MECHANICAL MACHINE BOLT MANUFACTURER MASONRY ISOLATED COPPER GROUND BUSICGB. INT. L.F. L. L.B. IN.(") LB.(#) INTERIOR INCH(ES) POUND(S) LAG BOLTS LINEAR FEET (FOOT) HDR. HT. HGR. GRND.GROUND HEADER HEIGHT HANGER SET POINT FND. MONUMENT SPOT ELEVATION LIGHT POLE TELEPHONE BOX ELECTRIC BOX SECTION REFERENCE ELEVATION REFERENCE GRID REFERENCE DETAIL REFERENCE X REVISION MATCH LINE PROPERTY/LEASE LINE CENTERLINE WOOD BLOCKING STEEL WOOD CONT. SAND OVERHEAD SERVICE CONDUCTORS CHAIN LINK FENCING T/E X TELEPHONE CONDUITT ELECTRICAL CONDUIT COAXIAL CABLE (POWER) E A WORK POINT GROUND CONDUCTOR 1ABBREVIATIONS 2LEGEND ABBREVIATION DEFINITION ABBREVIATION DEFINITION ABBREVIATION DEFINITION 3GENERAL NOTES UNLESS NOTED OTHERWISE WEIGHTWT. CL PL PLATE CENTERLINE W V.I.F. WD. W.P. W/ U.N.O. WITH WOOD WEATHERPROOF WIDE(WIDTH) VERIFY IN FIELD UNDERWRITERS LABORATORY TYP. T.O.S. T.O.W. U.L. U.G. T.O.P. TYPICAL UNDER GROUND TOP OF STEEL TOP OF WALL TOP OF PLATE (PARAPET) T.N. T.O.C. T.O.F. T.O.A. TOE NAIL TOP OF CURB TOP OF ANTENNA TOP OF FOUNDATION TMA TOWER MOUNTED AMPLIFIER RRU.RADIO REMOTE UNIT WOOD FENCE OVERHEAD POWER LINE BURIED POWER LINE BURIED WATER LINE BURIED SANITARY SEWER BURIED STORM DRAIN BURIED TELEPHONE LINE OVERHEAD TELEPHONE LINE FIBER POWER AND FIBER P/F F LANDLORD SIGNATURE GENERAL FIRE NOTES: 1.THIS FACILITY IS EXEMPT FROM HANDICAP REQUIREMENTS PER 2015 INTERNATIONAL BUILDING CODE SECTION 1103.2.9. THIS FACILITY IS NON-OCCUPIABLE SPACE AND ENTERED ONLY BY SERVICE PERSONNEL. THIS SPACE IS NOT FOR HUMAN OCCUPANCY. 2.THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO SUBMITTING BIDS, AND PROCEEDING WITH ANY WORK. 3.THE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY ERRORS, OMISSIONS, OR DISCREPANCIES AS THEY MAY BE DISCOVERED IN THE PLANS, SPECIFICATIONS, & NOTES PRIOR TO STARTING CONSTRUCTION. INCLUDING BUT NOT LIMITED BY DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERRORS, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE METHOD OF CORRECTION SHALL BE APPROVED BY THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT. 4.PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR HAS THE RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES, WHETHER OR NOT SHOWN ON THE PLANS, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR OR SUBCONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGE TO THE UTILITIES CAUSED DURING THE EXECUTION OF THE WORK. CONTACT USA DIG ALERT @ 800-227-2600 5.PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO PROPOSED OR EXISTING SURFACES, STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE PROPERTY OWNER. THE CONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING ANY DAMAGED AREAS. 6.A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL CONSTRUCTION SETS REFLECT THE SAME INFORMATION AS THE APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF DOCUMENTING ALL AS-BUILT CHANGES, REVISIONS, ADDENDA, OR CHANGE ORDERS. THE CONTRACTOR SHALL FORWARD THE AS-BUILT/HIRED DRAWINGS TO THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT AT THE CONCLUSION OF THE PROJECT. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE WORK IS IN PROGRESS UNTIL THE JOB IS COMPLETE. 8.THE CONTRACTOR IS RESPONSIBLE TO PROVIDE TEMPORARY POWER, WATER, AND TOILET FACILITIES AS REQUIRED BY THE PROPERTY OWNER OR GOVERNING AGENCY. 9.ALL CONSTRUCTION THROUGH THE PROJECT SHALL CONFORM TO THE LATEST I.B.C. AND ALL OTHER GOVERNING CODES, INCLUDING THE THE MOST RESTRICTIVE CODE SHALL GOVERN. 10.THE CONTRACTOR AND SUBCONTRACTOR SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS INCLUDING ALL OSHA REQUIREMENTS. 11.WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING OR BRACING SHALL BE PROVIDED WHERE THE STRUCTURE OR SOIL HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT. 12.THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK, USING HIS PROFESSIONAL KNOWLEDGE AND SKILLS. HE IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCING AND COORDINATING ALL PORTIONS OF THE WORK UNDER THE PROJECT. 13.THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL PERMITS, LICENSES AND INSPECTIONS WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR AUTHORIZED AGENT. CONTRACTOR SHALL OBTAIN THE PERMIT AND MAKE FINAL PAYMENT OF SAID DOCUMENT. 14.ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE. DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCES. 15.THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR SUPPORTS FOR INSTALLATION OF ITEMS INDICATED ON THE DRAWINGS. 16.THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL OR U.L APPROVED MATERIALS TO FILL/SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. GENERAL NOTES 17.PROPOSED CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN FORM, TEXTURE, MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS. 18.THE CONTRACTOR IS TO PROVIDE PORTABLE FIRE EXTINGUISHERS HAVING A MINIMUM 2A:10-B:C RATING WITHIN 75FT. OF TRAVEL TO ALL PORTIONS OF THE CONSTRUCTION AREA. (2015 INTERNATIONAL BUILDING CODE 906.1.1 AND SECTION 906.3.1) 19.MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AVAILABLE AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR APPROVING THE RESULTS. 20.ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE. 21.ALL DEBRIS AND REFUSE IS TO BE REMOVED FROM THE PROJECT. PREMISES SHALL BE LEFT IN A CLEAN BROOM FINISHED CONDITION AT ALL TIMES. 22.BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE NOTIFIED PRIOR TO ANY GRADING AND CONSTRUCTION EFFORT AS MANDATED BY THE GOVERNING AGENCY. 23. ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY STANDARDS. IF A CONTRACTOR HAS A QUESTION REGARDING THEIR EXACT MEANING THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT SHALL BE NOTIFIED FOR CLARIFICATIONS. 24. SITE CONTRACTOR TO CALL DIG ALERT (1-800-227-2600) TO LOCATE ANY AND ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. 25. ALL FACILITIES TO BE INSTALLED ARE UNMANNED. NO (E) PARKING SPACES WILL BE USED OR REMOVED BY THIS PROJECT. 26. PRIOR TO THE ISSUANCE OF ANY CONSTRUCTION PERMITS, THE APPLICANT SHALL INCORPORATE ANY CONSTRUCTION BEST MANAGEMENT PRACTICES NECESSARY TO COMPLY WITH THE CITY'S MUNICIPAL CODES INTO THE CONSTRUCTION PLANS OR SPECIFICATIONS. 27. PRIOR TO THE ISSUANCE OF ANY CONSTRUCTION PERMITS, THE APPLICANT SHALL SUBMIT A WATER POLLUTION CONTROL PLAN WPCP). THE WPCP SHALL BE PREPARED IN ACCORDANCE WITH THE GUIDELINES IN APPENDIX E OF THE CITY'S STORM WATER STANDARDS. 28. THIS PROJECT PROPOSES NO DEVELOPMENT IMPROVEMENTS OUTSIDE THE EXISTING BUILDING FOOTPRINT FOR THIS DISCRETIONARY REVIEW AND THEREFORE DOES NOT REQUIRE ANY PERMANENT STORM WATER BEST MANAGEMENT PRACTICES. 29. THIS IS ROOFTOP INSTALLATION ON AN EXISTING FACILITY AND NO GROUND DISTURBANCE OR TRENCHING IS PROPOSED BY THIS PROJECT. 30. THIS PROJECT PROPOSES NO WORK WITHIN THE PUBLIC RIGHT-OF-WAY. 1.BUILDINGS UNDERGOING CONSTRUCTION, ALTERATION, OR DEMOLITION SHALL BE IN ACCORDANCE WITH 2015 INTERNATIONAL BUILDING CODE AND ALL GOVERNING CODES. 2.ADDRESS SHALL BE PROVIDED FOR ALL PROPOSED AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.(2015 INTERNATIONAL BUILDING CODE 501.2) 3.DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.(2015 INTERNATIONAL BUILDING CODE 806.1) 4.PORTABLE FIRE EXTINGUISHERS: AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MAXIMUM TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR.(2015 INTERNATIONAL BUILDING CODE 906.1.1 AND SECTION 906.3.1) STORM WATER QUALITY NOTES CONSTRUCTION BMPS: THIS PROJECT SHALL COMPLY WITH ALL REQUIREMENTS OF THE STATE PERMIT. NOTES 1-6 BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION BMP'S. 1. SUFFICIENT BMPS MUST BE INSTALLED TO PREVENT SILT, MUD OR OTHER CONSTRUCTION DEBRIS FROM BEING TRACKED INTO THE ADJACENT STREET(S) OR STORM WATER CONVEYANCE SYSTEMS DUE TO CONSTRUCTION VEHICLES OR ANY OTHER CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING ANY SUCH DEBRIS THAT MAY BE IN THE STREET AT THE END OF EACH WORK DAY OR AFTER A STORM EVENT THAT CAUSES A BREECH IN THE INSTALLED CONSTRUCTION BMPS. 2.ALL STOCK PILES OF UN-COMPACTED SOIL AND/OR BUILDING MATERIALS THAT ARE INTENDED TO BE LEFT UNPROTECTED FOR A PERIOD GREATER THAN SEVEN CALENDAR DAYS ARE TO BE PROVIDED WITH EROSION AND SEDIMENT CONTROLS, SUCH SOIL MUST BE PROTECTED EACH DAY WHEN THE PROBABILITY OF RAIN IS 40% OR GREATER. 3. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECTS WHICH PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPROVEMENTS THAT ARE TO BE POURED IN PLACE ON THE SITE. 4. ALL EROSION/SEDIMENT CONTROL DEVICES SHALL BE MAINTAINED IN WORKING ORDER AT ALL TIMES. 5. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTIVITY MUST BE PROTECTED AGAINST EROSION AND SEDIMENT TRANSPORT AT ALL TIMES. 6. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRONMENT. SITEPLANA-1REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CGOVERALL SITE PLAN11.INFORMATION OBTAINED FROM DRAWINGS PREPARED BYCLS GROUP DATED 05/01/20182.CONTRACTOR TO SITE VERIFY ALL DIMENSIONS ANDCONDITIONS PRIOR TO CONSTRUCTION. REPORT ANYDISCREPANCIES TO THE ENGINEER.NOTES:1/32" = 1'-0" (11x17)SCALE:(OR)1/16" = 1'-0" (24x36)16'8'4'0NPROPERTY LINE 639.65' S88°56'13"EPROPERTY LINE 605.26 N01°15'21"E PROPERTY LINE 199.81' N 01°14'32" EPROPERTY LINE77.61' N01°13'56" ES 88°46'04"E 30.00'N 01°13'56" E 300.00'PROPERTY LINEPROPERTY LINE503.59' N 05°36'38" WS 29°31'23"E 27.41'PROPERTY L INE215.41' S 74°36 '50 " WPROPERTY L INE N 5 2 ° 4 8 ' 4 5 " E 4 0 0 . 0 0 'PROPERTY L INE N 5 0 0 . 4 0 ' N 5 0 ° 3 1 ' 1 9 " E223.61' N 79°22'39" EPROPERTY LINE8 5 . 5 8 'N5 2 ° 4 8 ' 4 5 "EEXISTINGBUILDINGS SR 1 8 WEYERHAEUSER WAY S. E X IS T ING P ARK ING EXISTING P ARK ING EX I S T I N G P A R K I N G EXIS TI N G P A R KI N G EXISTING PARKINGEXISTING PARKINGEXISTING PARK ING 86.43' S01°13'56" WEXISTING P ARK ING E X IS T ING P ARK ING E X IS T ING P ARK ING E X IS T ING P ARK ING E X I S T ING PAR K ING EXISTING PARKINGEXISTING PARKINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTINGBUILDINGEXISTING PARKINGE X I S T ING PAR K ING E X I S T ING P AR K ING E X IS T ING P ARK ING EXISTING AT&T ANTENNALOCATIONEXISTING AT&T EQUIPMENTLOCATIONEXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING EXISTING PARKING EQUIPMENTLAYOUTA-2REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CGN1EQUIPMENT LAYOUT3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'0EXISTING ROOFHATCHEXISTING AT&TEQUIPMENT/ANTENNALOCATIONEXISTING EDGEOF BUILDING ENLARGEDEQUIPMENTLAYOUTA-3REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CGN1ENLARGED EQUIPMENT LAYOUT3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'0EXISTING AT&TFIBER BOXEXISTING AT&TPURCELLCABINETEXISTINGAT&T TE43CABINETEXISTINGAT&T BBUCABINETEXISTINGAT&T POWERCABINETEXISTINGAT&T GSMCABINETEXISTINGAT&T TE40CABINETEXISTINGAT&T UMTSCABINETEXISTING AT&T MECHANICALSCREEN WALLEXISTING AT&T DC-2EXISTING AT&T FIBER SLACKBOXEXISTING AT&T RRH (TYP.)EXISTING AT&T ANTENNAS(TYP.)EXISTING AT&T ICE BRIDGEEXISTING AT&T RRH (TYP.)PROPOSED DC CONVERTERIN EXISTING SHELFPROPOSED (3) 25 AMPBREAKERS FOR RRH SERVICEPROPOSED (2) RECTIFIERS INEXISTING POWER PLANTPROPOSED ASIK AND ABILCARDS IN EXISTING CABINETEXISTING 24V PDU 4MARATHON BATTERIESEXISTING 10 MARATHONBATTERIES BUILDINGELEVATIONA-4REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CGN2EXISTING EQUIPMENT LAYOUT3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'01PROPOSED EQUIPMENT LAYOUT3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'0EXISTING AT&T ALPHASECTOREXISTING KATHREIN-742-264 UMTS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING KATHREIN-742-264 GSM ANTENNA(1 PER SECTOR, 3 TOTAL), TO BE REMOVEDEXISTING SBNHH-1D65B LTE WCS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING NNH4-65B-R6 LTE ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING AT&T BETA SECTOREXISTING 45'-0'' BUILDINGEXISTING AT&T ALPHASECTOREXISTING KATHREIN-742-264 UMTS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING SBNHH-1D65B LTE WCS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING NNH4-65B-R6 LTE ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING AT&T BETA SECTOREXISTING 45'-0'' BUILDINGPROPOSED AT&T 5G ANTENNA(1 PER SECTOR, 3 TOTAL) EXISTINGANTENNACONFIGURATIONA-5REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CG1EXISTING ANTENNA CONFIGURATION3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'0EXISTING COAX CONFIGURATION AND SCHEDULE v1.0, 06/26/2020ALPHAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS55°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOUMTS 1900/85055°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS55°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NOGSM 1900/85055°55'0"KATHREIN742-264(2) CS72993.08-47/8''50'-0"NOBETAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS230°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOUMTS 1900/850230°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS230°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NOGSM 1900/850230°55'0"KATHREIN742-264(2) CS72993.08-47/8''50'-0"NOGAMMAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS330°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOUMTS 1900/850330°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS330°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NOGSM 1900/850330°55'0"KATHREIN742-264(2) CS72993.08-47/8''50'-0"NO(E) "B" SECTOR @ 230°EXISTING GSM UMTS TMAS(4 PER SECTOR, 12 TOTAL)EXISTING NNH4-65B-R6 LTE ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING KATHREIN-742-264 UMTS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING KATHREIN-742-264 GSM ANTENNA(1 PER SECTOR, 3 TOTAL), TO BE REMOVEDEXISTING SBNHH-1D65B LTE WCS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING (3) LTE AIRSCALE DUALRRH 4T4R B12/14 320W AHLBA(1 PER SECTOR, 3 TOTAL)EXISTING (3) LTE AIRSCALE DUALRRH 4T4R B25/66 320W AHFIB(1 PER SECTOR, 3 TOTAL)EXISTING RRH4x25-WCS-4R(1 PER SECTOR, 3 TOTAL)EXISTING AT&T DC-2 UNIT(2 PER SECTOR, 6 TOTAL)(E ) "A " SECTOR @ 5 5 °(E) "G" SECTOR @ 330° PROPOSEDANTENNACONFIGURATIONA-6REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CG1PROPOSED ANTENNA CONFIGURATION3/32" = 1'-0" (11x17)SCALE:(OR)3/16" = 1'-0" (24x36)5'3'1.5'0(E) "B" SECTOR @ 230°EXISTING GSM UMTS TMAS(4 PER SECTOR, 12 TOTAL)EXISTING NNH4-65B-R6 LTE ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING KATHREIN-742-264 UMTS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING SBNHH-1D65B LTE WCS ANTENNA(1 PER SECTOR, 3 TOTAL)EXISTING (3) LTE AIRSCALE DUALRRH 4T4R B12/14 320W AHLBA(1 PER SECTOR, 3 TOTAL)EXISTING (3) LTE AIRSCALE DUALRRH 4T4R B25/66 320W AHFIB(1 PER SECTOR, 3 TOTAL)EXISTING RRH4x25-WCS-4R(1 PER SECTOR, 3 TOTAL)EXISTING AT&T DC-2 UNIT(2 PER SECTOR, 6 TOTAL)(E ) "A " SECTOR @ 5 5 °(E) "G" SECTOR @ 330°PROPOSED COAX CONFIGURATION AND SCHEDULE v1.0, 06/26/2020ALPHAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS55°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOUMTS 1900/85055°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS55°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NO5G 85055°55'0"COMMSCOPENNHH-65B-R4-(1) 4T4R B5 AHCA-FIBER50'-0"NOBETAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS230°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOGSM 1900/850230°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS230°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NO5G 850230°55'0"COMMSCOPENNHH-65B-R4-(1) 4T4R B5 AHCA-FIBER50'-0"NOGAMMAAZIMUTHRAD CENTERVENDORMODELTMARRHNUMBEROF COAXCOAX ØCOAXLENGTHDIPLEXEDLTE 1900/700/AWS330°55'0"COMMSCOPENNH4-65B-R6-RRH 4T4R B12/14 320W AHLBARRH 4T4R B25/66 320W AHFIB-FIBER50'-0"NOUMTS 1900/850330°55'0"KATHREIN742-264(2) LGP 21401-27/8''50'-0"NOLTE WCS330°55'0"COMMSCOPESBNHH-1D65B-(1) RRH4x25-WCS-4R-FIBER50'-0"NO5G 850330°55'0"COMMSCOPENNHH-65B-R4-(1) 4T4R B5 AHCA-FIBER50'-0"NOPROPOSED 5G AIRSCALE 4T4R B5 AHCA(1 PER SECTOR, 3 TOTAL)PROPOSED 5G AIRSCALE 4T4R B5 AHCA(1 PER SECTOR, 3 TOTAL)PROPOSED 5G AIRSCALE 4T4R B5 AHCA(1 PER SECTOR, 3 TOTAL)PROPOSED AT&T 5G ANTENNA(1 PER SECTOR, 3 TOTAL)PROPOSED AT&T 5G ANTENNA(1 PER SECTOR, 3 TOTAL) DETAILSA-7REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CG AHCA RRH DETAIL3N.T.S.SCALE9N.T.S.SCALE8N.T.S.SCALE6N.T.S.SCALE5N.T.S.SCALE2N.T.S.SCALEN.T.S.SCALE14N.T.S.SCALE7N.T.S.SCALE10N.T.S.SCALE11N.T.S.SCALE12N.T.S.SCALENOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOKIA AIRSCALE RRH 4T4R B5 160W AHCADIMENSIONS, HxWxD: 13.3" x 11.6" x 6.5"WEIGHT: 36.8 lb11.6''13.3''6.5''NOT USEDNOT USEDANTENNA DETAILCOMMSCOPE NNH4-65B-R472.0"7.8"19.6"DIMENSIONS, HxWxD:72.0" x 19.6" x 7.8"WEIGHT:78.5 lbRF CONNECTOR:(8) 4.3-10 FEMALERECTIFIER DETAILCORDEX 3.1KW 24Vdc MODULAR RECTIFIERDIMENSIONS, HxWxD:6.3" x 3.4" x 11.8"(WITHOUT BRACKETS)WEIGHT:101 lbs(MOUNTED WEIGHT)INPUT VOLTAGE:208-277 VacOUTPUT VOLTAGE:21-29VdcOUTPUT CURRENT:115A @ 27VdcOUTPUT POWER:3100W COMPLIANCEA-8REVDESCRIPTIONDATEABY90% CD10/06/2020UNLESS THEY ARE ACTING UNDER THE DIRECTIONIT IS A VIOLATION OF LAW FOR ANY PERSON,OF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.16212 Bothell-Everett HwySuite F304,Mill Creek, WA 98012AT&T MOBILITYRTC BUILDING 318221 NE 72nd WAYREDMOND, WA 9805222263 68th AVE SKENT, WA 98032SS81WEYERHAEUSER33940 WEYERHAEUSER WAY SFEDERAL WAY,WA 98001CGNetwork Solutions11/10/20201100% CONSTRUCTION DRAWING11/10/2020CGN.T.S.SCALE1ROOF PLAN2N.T.S.SCALENOTICE 2 SIGNNOTICEPROPOSED CAUTION 2 SIGNS ONPROPOSED AT&T BARRIERSALPHA SECTOR·35 BY 25 FOOT BARRIER AND 12 FOOT BARRIER IN FRONT OF THE ANTENNAS.·YELLOW CAUTION 2 SIGNS ON THE FRONT AND BACK OF THE ANTENNA ARRAY . YELLOWCAUTION 2 SIGNS POSTED EVERY 8 FEET ON THE BARRIER NEAR THE ANTENNAS.BETA SECTOR·YELLOW CAUTION 2 SIGNS ON THE FRONT AND BACK OF THE ANTENNA ARRAY . YELLOWCAUTION 2 SIGNS POSTED EVERY 8 FEET ON THE BARRIER NEAR THE ANTENNAS.GAMMA SECTOR·SHARED (WITH SECTOR A) 35 BARRIER NEAR THE ANTENNAS·YELLOW CAUTION 2 SIGNS ON THE FRONT AND BACK OF THE ANTENNA ARRAY . YELLOWCAUTION 2 SIGNS POSTED EVERY 8 FEET ON THE BARRIER NEAR THE ANTENNAS.3N.T.S.SCALESTANCHION DETAIL1.INSTALL SIGNS AND BARRIERS PER PLAN.2.NOTICE 2 SIGNS ON STANCHIONS SHALL BE 8"x12", ALUMINIUM.3.SIGNS ON SCREEN/PARAPET 5"x7" (CAUTION 2C) PREFERREDBUT 8x12 (CAUTION 2) IS ALLOWED4.BARRIER STANCHIONS SHALL BE OUTDOOR RATEDPOLYETHYLENE, MIN 24" HIGH, WITH NON PENETRATING BASE.3/8" OUTDOOR RATED PLASTIC CHAIN SHALL BE INSTALLEDBETWEEN STANCHINOS.NOTES:NOTES:8'-0''MAX35'25'35'PROPOSED CAUTION 2 SIGNS ONPROPOSED AT&T BARRIERSPROPOSED CAUTION 2 SIGNS ONPROPOSED AT&T BARRIERSPROPOSED CAUTION 2 SIGNS ONPROPOSED AT&T BARRIERSPROPOSED CAUTION 2 SIGNS ON FRONTAND BACK OF ANTENNA ARRAYSPROPOSED CAUTION 2 SIGNS ON FRONTAND BACK OF ANTENNA ARRAYSPROPOSED CAUTION 2 SIGNS ON FRONTAND BACK OF ANTENNA ARRAYS12' GROUNDING PLANS REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG G-1 REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG 3ANTENNA GROUNDINGNOTES & LEGENDS NOTE: 1. CONTRACTOR TO REPLACE ALL MISSING GROUND BARS AND GROUNDING CONNECTIONS AS REQUIRED. EXOTHERMIC CONNECTION LEGEND ELECTRICAL GROUNDING SPECIFICATIONS 1.GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING JURISDICTION. 2.ALL GROUNDING DEVICES SHALL BE U.L. LISTED FOR THEIR INTENDED USE. 3.GROUND WIRES SHALL BE TINNED #2 AWG BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4.CONNECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED), UNLESS OTHERWISE NOTED. AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND T-MOBILE WIRELESS BROADBAND STANDARDS. 5.GROUNDING CONDUCTORS SHALL BE ROUTED ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. WHEN REQUIRED, GROUND LEADS SHALL BE BENT TO A MINIMUM OF 8" RADIUS. 6.WHERE GROUND WIRES ARE ROUTED FROM ANY CONNECTION ABOVE GRADE TO THE GROUND RING. INSTALL WIRE IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5" BELOW GRADE AND SEAL THE TOP WITH SILICONE SEALANT. 7.ALL GROUND BARS SHALL BE TINNED, 1/4" COPPER, SECTOR BARS 2", COLLECTOR AND MGB BARS 4", OF SUFFICIENT LENGTH TO ACCOMMODATE ALL REQUIRED CONNECTIONS WITHOUT DOUBLING LUGS, AND EACH INSTALLED WITH ISOLATORS. WHEN CONNECTING GROUND BARS (WITHIN 10 FEET OF GRADE) DIRECTLY TO THE GROUND RING, 2 EA. #2 SOLID DOWNLEADS SHALL BE CAD-WELDED TO THE GROUND BAR, 1 AT EACH OPPOSITE BOTTOM CORNER, AND EACH SHALL RUN IN 3/4" HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT FROM GROUND BAR DOWN TO THE GROUND RING. WHEN CONNECTING SECTOR GROUND BARS, DAISY-CHAIN THE GROUND BARS AND RUN 1 EA. #2 AWG STRANDED COPPER WIRE WITH THWN INSULATION FROM THE MIDDLE GROUND BAR TO THE GROUND RING AND CAD-WELD TO THE RING. 8.WHEN ATTACHING STRANDED GROUND LEADS TO THE GROUND BARS, 2 HOLE COMPRESSION LUGS SHALL BE USED, PROTECT WITH WEATHERPROOF HEAT SHRINK, AND WITH A THIN COAT OF "KOP'R SHIELD" OR EQUIVALENT PROPERLY APPLIED AND ATTACHED ONLY WITH STAINLESS STEEL HARDWARE. 9.WHEN GROUNDING EQUIPMENT ENCLOSURES, PANELS, FRAMES, AND OTHER METAL APPARATUS, A #6 AWG STRANDED COPPER WIRE WITH THWN INSULATION SHALL BE ATTACHED UTILIZING A 2 HOLE COMPRESSION TYPE LUG, PROTECTED WITH WEATHERPROOF HEAT A CLEAN AND CORROSION FREE METALLIC SURFACE UTILIZING STAINLESS STEEL SELF-TAPPING SCREWS AS NOTED IN NOTE 10 BELOW. 10.PREPARE ALL BONDING SURFACES FOR GROUND CONNECTIONS BY REMOVING ANY AND ALL PAINT AND CORROSION TO SHINY METAL. FOLLOWING CAD-WELDED CONNECTIONS TO NON-COPPER SURFACES, APPLY ONE COAT OF ANY ANTI-OXIDIZING PAINT, "COLD GALV" OR EQUIVALENT. 11.GROUND RODS SHALL BE COPPER-CLAD STEEL 5/8"x10', SPACED NO LESS THAN 10' ON CENTER. 12.ALL GROUND SYSTEM CONDUCTORS AND CONDUITS SHALL BE SECURED UTILIZING ONLY NONMETALLIC, NON-CONDUCTIVE, UV RATED CLAMPS, BRACKET, AND OR SUPPORTS. 13.WHEN REQUIRED, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF AN INDEPENDENT TESTING FIRM TO VERIFY, UTILIZING A MEGGER TEST, THAT THE RESISTANCE TO EARTH OF THE NEW GROUND SYSTEM IS EQUAL TO OR LESS THAN 5 (OHMS). A COPY OF THE COMPLETE TESTING REPORT SHALL BE PROVIDED TO THE T-MOBILE REPRESENTATIVE. 14.ALL MATERIALS AND HARDWARE SHALL BR INSTALLED IN A WORKMAN-LIKE MANNER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, AND DEFINED IN NFPA-70 AND APPROVED BY A,H,J, MECHANICAL CONNECTION EQUIPMENT GROUND BAR ANTENNA GROUND BAR (AS REQUIRED) #2 AWG GROUND LEAD (AS REQUIRED) 1 NEW #6 AWG FROM PROPOSED EQUIPMENT TO EXISTING GROUND BAR NEW #6 AWG FROM PROPOSED EQUIPMENT TO EXISTING GROUND BAR GROUNDING DETAILS REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG G-2 REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG TYPE VV TYPE GT TYPE TA TYPE GY TYPE GR TYPE VN TYPE NC TYPE VS TYPE VB TYPE SS TYPE PT NOTE: ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 EXOTHERMIC WELDING N.T.S. SCALE NOT USED TWO-HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4" STAINLESS STEEL HEX UNIT BOLTS AND HARDWARE. NEW 4"x12"x1/4" THK., TINNED GROUND BAR ON WALL SECTOR GROUND BAR EXOTHERMIC WELD NEW #2 AWG SOLID TINNED BARE Cu WIRE TO MAIN GROUND BAR NOTES: 1.PROVIDE NO-OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR 2.CONTRACTOR WILL VERIFY BUSS BAR GROUNDING TO BUILDING STEEL. 3.GROUND BARS AT BOTTOM SHALL USE EXOTHERMIC CONNECTION. 12" TO 24" CABLE GROUNDING 2 1/2"ØMAX.ANTENNA CABLE CABLE GROUND KIT ANTENNA AND/OR GPS CABLE CONNECTION NOTES: 1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2.GROUNDING KIT TYPE SHALL BE APPROVED BY TMO PRIOR TO INSTALLATION 3.WEATHERPROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT, COLD SHRINK SHALL NOT BE USED. #6 AWG STRANDED Cu WIRE WITH GREEN, 600V,THWN INSULATION OR BLACK (GROUNDED TO GROUND BAR) CABLE CONNECTOR WEATHERPROOFING KIT (SEE NOTE 3) 3" MIN. NOTES: 1.ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER, GROUND BAR, GROUND LUG, FLAT WASHER, LOCK WASHER AND NUT. 2.COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT SHALL BE PLACE WHERE ALL DISSIMILAR METALS CONNECT. 3.ALL LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4.ALL LUGS MUST HAVE INSPECTION WINDOWS.BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) BARE WIRE TO BE NO-OX AT BOTH ENDS GROUNDING CONDUCTOR HEAT SHRINK (CLEAR HEAT SHRINK INDOOR & BLACK HEAT SHRINK OUTDOOR) NUT (TYP.) BOLT (TYP.) GROUND BAR WIRE SIZE #6 AWG GREEN INSULATED #2 AWG SOLID TINNED #2 AWG STRANDED #2/0 AWG STRANDED #4/0 AWG STRANDED YA6C-2TC38 YA3C-2TC38 YA2C-2TC38 YA26-2TC38 YA28-2N 1/2" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT 3/8" - 16 NC S 2 BOLT BURNDY LUG BOLT SIZE MECHANICAL LUG FLAT WASHER (TYP.) FLAT WASHER (TYP.) LOCK WASHER (TYP.) BURNDY GROUND LUG (SEE TABLE FOR SIZE AND MODEL) MAIN GROUND BAR NEW MAIN GROUND BAR NEW #6 AWG STRANDED Cu WIRES TO EXISTING EQUIPMENT TWO-HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4"STAINLESS STEEL HEX UNIT BOLTS AND HARDWARE. NOTES: 1.PROVIDE NO-OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR 2.CONTRACTOR WILL VERIFY BUSS BAR GROUNDING TO BUILDING STEEL. 3.GROUND BARS AT BOTTOM SHALL USE EXOTHERMIC CONNECTION. EXOTHERMIC WELD NEW (2) #2 AWG SOLID TINNED BARE Cu WIRE TO EXISTING GROUND RING NOT USED NOT USED N.T.S. SCALE 1 2N.T.S. SCALE 3N.T.S. SCALE 4N.T.S. SCALE 5N.T.S. SCALE 6N.T.S. SCALE 8N.T.S. SCALE 10N.T.S. SCALE 11N.T.S. SCALE 12N.T.S. SCALE NOT USED 9N.T.S. SCALE NOT USED NOT USED NEW RACK, PPC CABINET, TELCO CABINET, SERVICE LIGHT, AND COVP GROUNDING KIT: #6 AWG STRANDED Cu WIRE WITH GREEN, 600V, THWN INSULATION OR BLACK ANTENNA, FRBG, FHFB, FRIJ, ANTENNA MOUNT, GPS, AND COVP GROUNDING KIT: #6 AWG STRANDED Cu WIRE WITH GREEN, 600V,THWN INSULATION OR BLACK RF DETAILS REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG RF-1 REV DESCRIPTIONDATE A BY 90% CD10/06/2020 UNLESS THEY ARE ACTING UNDER THE DIRECTION IT IS A VIOLATION OF LAW FOR ANY PERSON, OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 16212 Bothell-Everett Hwy Suite F304, Mill Creek, WA 98012 AT&T MOBILITY RTC BUILDING 3 18221 NE 72nd WAY REDMOND, WA 98052 22263 68th AVE S KENT, WA 98032 SS81 WEYERHAEUSER 33940 WEYERHAEUSER WAY S FEDERAL WAY, WA 98001 CG Network Solutions 11/10/2020 1 100% CONSTRUCTION DRAWING11/10/2020 CG