Loading...
22-103422-00City of Federal Way Community Development Dept, 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) B35-2609 Building - Single Family Permit #:22-103422-00-SF Inspection Request Line: (253) 835-3050 Project Name: THE WOODLANDS AT REDONDO CREEK LOT 7 Project Address: 1907 S 301ST CT Parcel Number: 952651 0070 Project Description: BLUEBEAM - Construction of a 1860 square foot, 2-story. single family residence with a 75 square foot covered entry, and a 37.1 square foot attached garage. Owner Applicant Contractor Lender SSHI LLC DBA D R HORTON JESS BOSANCUD R HORTON D R HORTON OWNER IS LENDER 11241 SLATER AVE NE SUITE 12C 11241 SLATER AVE NE SUITE 120 11241 SLATER AVE NE SUITE 120 KIRKLAND WA 98033 KIRKLAND WA 98033 KIRKLAND WA 98033 Census Category: 101 - New Single Family House Includes: Occupant Class: #1 R-3 #2 #3 #4 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 1,860.00 Additional Permit Information New / Additional Sq. Feet - 1 st Floor ..................... 973 New / Additional Sq. Feet - 2nd Floor.................... 887 New / Additional Sq. Feet - 3rd Floor ..................... 0 Occupancy # 1 - Area (Sq. Feet) ................................ 1860 New /Additional Sq. Feet -Basement .................... 0 Basic Plan?........................................................... No Occupancy #1 - Construction Type ......................... Type V - B New / Additional Sq. Feet - Deck ........................... 0 New / Additional Sq. Feet - Garage ........................ 371 Mechanical to be Included?..................................... Yes Plumbing Work Valuation? ..................................... 25000 Mechanical Work Valuation?................................... 20000 Number of Stories ........ .................... __........ »..».... 2 New / Additional Sq. Feet - Other ........................... 75 Plumbing to be Included?............ Yes New / Additional Sq. Feet - Total .......................... 2306 Will Certificate of Occupancy be Issued? ............... Yes Occupancy #1 - Use ................................................ Residence (1 or 2 family) Comprehensive Plan Designation ........................... SF - High -Density Zoning Designation ................................................. RS 5.0 Residential Total Valuation: 249,604.64 Mechanical Fixtures, Ducting 1 Fans 5 Furnaces 1 Gas Piping 1 Gas Pipe Outlets 2 Plumbing Fixtures Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1 Lavatories 4 Showers 2 Sinks 1 Water Closets ; Water Heaters 1 Hose Bibbs 2 CONDITIONS: 1. No part of the main structure may extend into the front yard setback. Eaves/awnings may extend up to 18 inches into the required front yard - compliance with FWMC 19.125.160 required. PERMIT EXPIRES Sunday, 4 June, 2023 Permit Issued on Tuesday, December 6, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Wash tan and the City of Federal Way. Owner or agent: r� Date: City of Federal Way Certificate of occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: THE WOODLANDS AT REDONDO CREEK LOT Address: 1907 S 301ST CT Includes: #1 42 #3 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 1,860.00 Owner Name: SSHI LLC DBA D R HORTON Owner Address: 11241 SLATER AVE NE SUITE 120 KIRKLAND WA 98033 Permit # 22-103422-00-SF #4 Date The priority focus in the it view and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. CITY OF 4:&� Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 22 103422 00 Address: 1907 S 301ST CT Project: D R HORTON FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Q SWM Precon Site Mtg (4400) 0 Site Assessment (Erosion) (4365) Q Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By ^� Date l I7i s❑ Foundation Wall (4115) 6❑ Drainage/Downspout (4040) © Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover By Date j �,� By // �U Date Il f By �7 � Date 1-1—flY/ 0 Slab/Concrete Floor (4255) Q Underfloor Framing (4285) 0 Floor Sheathing (4105) By Approved to place concrete Date By Approved to sheath floor V Date 2 �/ By Approved to install ilooriilg Date 9U Shear Walls (4245) l Roof Sheathing (4220) 12 Rough Plumbing (4230) Approved to install siding Approved to install roofing Approved By Date r '-I, By G Date By Date 73 Mechanical Rough -in (4165) 14 Gas Piping (4125) 0 Fire/Draft Stops (4095) Approved Approved to release test Approved By Q Date Z By Date '�j % By d Date IZ15 16 Interim Erosion Control (4370) Approved By Date Prior to scheduling a Framing inspection; 17 Electrical, Plumbing & Mechanical Rough -in Fire/Draft Stop inspections must be signed- off and approved. 1BC 109.3.4 By Framing (4120) Approved to insulateand LJ Date 0 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 0 Final Erosion Control (4375) Approved to install wallboard Approved to install mud & tape Approved By v Date O 2� By [] Date _3 t' Z By Date El Final - Mechanical (4065) 2'- Final - Plumbing (4075) 2s Final - Building (4050) Approved Approved Approved By Date 'S ?j3 By d Date vl L3 By Date �p ffc, G OK I� Rough Electrical El Final Electrical El Right of Way Approved Approved Approved By Date By Date By Date 'k Az� 4111 ADDRESS CITY OF Building Division 33325 Eighth Avenue South Federal Way Federal Way, 98003-6325 Phone 253-835-2607 Faxx 253-835835-2609 CORRECTION NOTICE \,tG�+ S , 76 (sf Cr PERMIT#: z- 0-/ ZZ -GQ IF YOU HAVE QUESTIONS CALL lie- (253) 835- IZ6 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. -tALh� ao DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of 1�Federal Way CITY OF Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: �� 07- S• EjOI 7�_ CT PERMIT#: ON,- )O ? Z .--0CP IF YOU HAVE QUESTIONS CALL (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of 1�Federal Way CITY OF Building Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: «U� 5� � 0 ( S� cr PERMIT#: 1in qZZ -Cr) IF YOU HAVE QUESTIONS CALL�&Y-elutA(253) 835- ?"c 2T WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 8 5-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. Z &,-­7 �C DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of