Loading...
23-102216City of Federal Way Community Development DepL 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: PET SUPPLIES PLUS Project Address: 1701 S COMMONS Project Description: BLUEBEAM - Installation of display racks. Building - Commercial Permit #:23-102216-00-CO Inspection Request Line: (253) 835-3050 Parcel Number: 762240 0015 Owner Applicant Contractor Lender MERLONE GEIER PARTNERS JOHN RICHARDSARCON ARCON CONSTRUCTION 457 SW 148TH ST SUITE 202 CONSTRUCTION 2100 124TH AVE NE BURIEN WA 98166 2100 124TH AVE NE BELLEVUE WA 98005 BELLEVUE WA 98005 Census Category: 437 - Commercial alt / add / conversion Includes: # 1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? ..................................... No Plumbing Work Valuation? ........... --- .... .............. - 0 Mechanical Work Valuation? .................................. 0 Number of Stories................... 2 Is this an Online or O.T.C. application? .................. No Permit for Building Shell Only?............................:. No Plumbing to be Included? ........................................ No Comprehensive Plan Designation ... ........................ City Center Core Zoning Designation ................................................. CC-C No Fixtures Associated With This Permit 11 PERMIT EXPIRES Wednesday, 25 October, 2023 Permit Issued on Friday, April 28, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: V.Date: fJAAl r THIS CARD IS TO REMAIN ON -SITE C1TV GF '"�"`- ''" Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 23 102216 00 Address: 1701 S COMMONS Project: MERLONE GEIER PARTNERS FEDERAL WAY WA 98003-8548 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑ Footings/Setback (4110) 2❑ Re -steel (4215) Q Slab/Concrete Floor (4255) Approved to place concrete Approved to place concrete or grout Approved to place concrete By Date By Date By Date ] By Underfloor Framing (4285) Approved to sheath floor Date By Floor Sheathing (4105) Approved to install flooring Date ® By Fire/Draft Stops (4095) Approved Date Prior to scheduling a Framing inspection; 7❑ Framing (4120) ® Insulation (4150) Electrical, Plumbing & Mechanical Rough -in Approved to insulate Approved to install wallboard and Fire/Draft Stop inspections must be signed - off and approved. IBC 109.3.4 By Date By Date Q Gypsum Wallboard Nailing (4130) Suspended Ceiling Grid (4265) ❑ Final - S K F & R (4060) Approved to install mud & tape Approved to drop tile Approved By Date By Date By Date T2 Final - Planning 73 Final - Building (4050) Approved Approved By Date By A Date ❑ Rough Electrical ❑ Final Electrical ❑ Right of Way Approved Approved Approved By Date By Date By Date GEOT E S T i EicI i , n [3elh,g1-, yinGal<1-,�i EXPANSION. ANCHOR INSPECTION REPORT PROJECT: Pet Supplies Plus JOB #: 23-0087 ADDRESS: 1701 South Commons, Federal Way, WA REPORT#: EA001 PERMIT M 22-102239-00 DATE: 2116/2023 CLIENT: Arcon Tenant Improvements Contractors PAGE #: 1 of 4 CONTRACTOR: Arcon Tenant Improvements Contractors INSPECTOR: Tim Martin Item(s'1 inspected Location Anchor Bolts for Racking Anchor Plates Al Light Duty Storage Shelving Fixtures Reference Drawing(s): A2.0, 23-0102-A Items) Inspected Comments Base Material Condition Fully cured Concrete, 49° Indoors Drill Bit Type Masonry Bit with a Roto-Hammer Hole Diameter/Depth 3/8" X 3-1/4" Hole Cleanliness (If Applicable) Clean Anchor Type/Name/Dimensions See Image #3 Anchor Spacing/Edge Distance [j Per Plan, NA Anchor Embedment 3" Anchor Torque/Displacement 30 ft. lbs. AnchorlCC-ES Report 3889 Other The above items were conforming ie Nonconforming Items (see below) L] Comments: GeoTest was on site as requested to inspect the installation of the above anchor bolts. The anchor bolts were found to conform with the above drawings and with the Seismic Analysis for Light Duty Fixtures. The manufacturer's instructions were followed in the anchor bolt installation. COPIES: glenn@aroon.constructlon, Jwllson@arcon-tl.com Reviewed by This report shell not be reproduced except In full, without the written approval of GeoTest Services, Inc. GEOTEST EXPANSION ANCHOR INSPECTION DEPORT 858 25152 76 BeUingh nm i Awngron I Oak harbor woa.+igeote5r-rnc corn PROJECT: Pet supplies Plus JOB M 23-0087 CLI ENT: Arcon Tenant Improvements Contractors DEPORT M EA001 CONTRACTOR: Arcon Tenant Improvements Contractors PAGE M 2 of 4 Image #1: One of the anchor plates prior to installing the anchor bolts. Image #2: Interior racking. GEOTEST Oak 11C 1:0,!, EXPANSION ANCHOR INSPECTION REPORT PROJECT: Pet Supplies Plus CLIENT: Arcon Tenant Improvements Contraptors CONTRACTOR: Arcon Tenant Improvements Contractors Image #3: Bolts used to anchor the racking. REPORT #: EA001 PAGE #: 3 of 4 Feb 16,2023 11:44,22 AM J. a dex . n o, m,, �g, , 1 �4O 2. GEOT!E T . • 1 EXPANSION ANCHOR INSPECTION REPORT PROJECT: Pet Supplies Plus CLIENT: Arcon Tenant Improvements Contractors CONTRACTOR: Arcon Tenant Improvements Contractors Image #4: Installing the anchor bolts. f;Ili,.gh;m', JOB M 23-0087 REPORT M EA001 PAGE M 4 of 4 GEOTEST 1 8 ' ' S _51 ST7c L ^Ilmr h:; n-, ;i rndt.�.i Oak•-,,,T L_.r qeo, (—_q - .ncco-n EXPANSION ANCHOR INSPECTION REPORT PROJECT: Pet Supplies Plus JOB M 23-0087 ADDRESS: 1701 South Commons, Federal Way, WA REPORT #: EA002 PERMIT M 22-102239-00 DATE: 2/17/2023 CLIENT: Arcon Tenant Improvements Contractors PAGE #: 1 of 3 CONTRACTOR: Arcon Tenant Improvements Contractors INSPECTOR: Guy Hailey Itern(s) Inspected Location Dowell 3'Screw-Bolt+ Installation for Seizmic Inc Racking System Seizmic Inc. Racking Systems at GL C.5-E.5 and U-15 Reference Drawing(s): A2.0, 23-0102A Item(s) Inspected Comments Base Material Condition Fully Cured Concrete at 51 F. Drill Bit Type ANSI Carbide, Rotohammer Hole Diameter/Depth lr 3/8" X 3 14' Hole Cleanliness (If Applicable) g Brush and Vacuum Anchor Type/Name/Dimensions be Dewalt 3" X 3/8" Screw -Bolt+ Anchor Spacing/Edge Distance Rr Per Plan Anchor Embedment lr 3" Anchor Torque/Displacement F�f 30 ft. lbs. 3889 Anchor ICC-ES Report Other The above items were conforming Rr Nonconforming Items (see below) ji Comments: GeoTest was on site per request to provide a special inspection for the installation of the above -mentioned seismic racking system anchor bolts. The anchor bolts were installed in accordance with the contract documents and the approved engineering drawings and with the manufacturer's printed/published installation instructions. COPIES: glenn@arson construction, jwllson@arson-tl.com ' Reviewed by This report shall not be reproduced except in full, without the written approval of GeoTesl Services, Inc. GEGTEST EXPANSION ANCHOR INSPECTION REPORT 1 998 'SI 5-1W B Irii•-�jhnrn', An,ng-mnOak iarbDr PROJECT: Pet Supplies Plus JOB M 23-0087 CLIENT: Arcon Tenant Improvements Contractors REPORTM EA002 CONTRACTOR: Arcon Tenant Improvements Contractors PAGE M 2 of 3 Image 1. The contractor installed one of the bolts to the racking system footing brackets. GEGTg;ST EXPANSION ANCHOR INSPECTION REPORT eas zsi 5276 D"hngh "1 i i A1lingron ; Oak : 4nrbar PROJECT: Pet Supplies Plus JOB M 23-0087 CLIENT: Arcon Tenant Improvements Contractors REPORT M EA002 CONTRACTOR: Arcon Tenant Improvements Contractors PAGE M 3 of 3 Image 2. Typical footing bracket post -installed, The bolts were verified for the proper torque requirement (30 ft.lbs.) using a calibrated torque wrench during the inspection. City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Building - Single Family Permit #:22-105699-00-SF Inspection Request Line: (253) 835-3050 Project Name: TAYLOR Project Address: 1247 SW 296TH ST Parcel Number: 515320 0030 Project Description: BLUEBEAM - Building a 350 sgft ground level deck with an attached 224 sgft pergola above. Attached to the back of the residence. Owner- Applicant Contractor Lender BRUCE TAYLOR TARA KADDOURA MASTERDECKS LLC 1247 SW 296TH ST 16910 59TH AVE NE SUITE 215 16910 59TH AVE NE SUITE 215-216 FEDERAL WAY WA 98023 ARLINGTON WA 98223 ARLINGTON WA 98223 Census Category: 434 - Residential alt/add - no change in number of units Includes: # 1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) Additional permit Information Occupancy # 1 - Construction Type ......................... Type V - B New / Additional Sq. Feet - Deck ........................... 350 New / Additional Sq. Feet - Garage ........................ 00 Mechanical to be Included?..................................... No Plumbing Work Valuation? ..................................... 0 Mechanical Work Valuation?.................................. 0 Number of Stories ................................................... I New / Additional Sq. Feet - Other........................... 00 Is this an Online or O.T.C. application? ...............:.. No Plumbing to be Included?........................................ No New / Additional Sq. Feet - Total ........................... 350 Occupancy #1 - Use................................................ Residence (1 or 2 family) Comprehensive Plan Designation ........................... SF - High -Density Zoning Designation ................................................. RS 15.0 Residential Total Valuation: 30,975.00 WM TM ftrOlt 11 PERMIT EXPIRES Saturday, 22 July, 2023 Permit Issued on Monday, January 23, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of ederal Way. Owner or agent: _ Date: i...-.. . iTHIS CARD IS TO REMAIN ON -SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 22 105699 00 Address: 1247 SW 296TH ST Project: NANCY LISELLE BAYLOR-TAYLOR FEDERAL WAY WA 98023-3410 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. EJ SWM Precon Site Mtg (4400) 0 Site Assessment (Erosion) (4365) ❑ Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date By Date By Date Q Foundation Wall (4115) ❑ Drainage/Downspout (4040) ❑ Slab/Concrete Floor (4255) Approved to place concrete Approved to back fiII Approved to place concrete By Date By Date By Date 7❑ Underfloor Framing (4285) ❑ Floor Sheathing (4105) ❑ Shear Walls (4245) Approved to sheath floor Approved to install flooring Approved to install siding 13v �Zr3 Date 2� By Date By Date 10 Roof Sheathing (4220) ❑ Fire/Draft Stops (4095) 12 Interim Erosion Control (4370) Approved to install roofing Approved Approved By Date By Date By Date ❑ Gypsum Wallboard Nailing (4130) ❑ Final Erosion Control (4375) E ] Final - Building (4050) Approved to install mud & tape Approved Approved By Date By Date By U Date Rough Electrical Final Electrical ❑ Right of Way Approved Approved 1By Approved By Date By Date Date CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, 98003-6325 y Phone 253-835-2607 Faxx 253-835835-2609 CORRECTION NOTICE ADDRESS: 1-2"'(;w A6� g5f. . PERMIT#: ,�%n Im Jr� IF YOU HAVE QUESTIONS CALL 'C) (e YLW (253) 835 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253 35-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of CITY OF Building Division 33325 Eighth Avenue South Federal Wa Federal Way, WA 98003-6325 4:�k�y Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: SW 290 It PERMIT#: 27 I6GW761-_00 IF YOU HAVE QUESTIONS CALL 'C/Y a ma (253) 835- 2K !,-q" WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 8 5-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. 15� 0 DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of