21-102872-AD-Plan Set-08-09-2021-V1TITLE SHEET
T-1.0
APPROVED BY SIGNATURE
CONSTRUCTION MANAGER
PROJECT MANAGER
DATE
SITE ACQUISITION
CONSTRUCTION MANAGER
DOCUMENT REVIEW SIGN OFF
PROJECT CONTACT LIST
PROJECT INFORMATION
ZONING CLASSIFICATION:
CODE INFORMATION:
RS7.2 (SINGLE FAMILY RESIDENTIAL)
BUILDING CODE:IBC 2018
CONSTRUCTION TYPE:IIB
OCCUPANCY:U
JURISDICTION:CITY OF FEDERAL WAY
PROPOSED BUILDING USE:UNMANNED TELECOM
LATITUDE:
SITE LOCATION (NAD83):
47° 21' 03.98" N
LONGITUDE:122° 18' 08.89" W
TOP OF STRUCTURE:568.30'± AMSL
BASE OF STRUCTURE:464.5'± AMSL
SEE LEASE AGREEMENT
PROJECT LEASE AREA:
7204800041
PARCEL NUMBER:
1.86 ACRES
AREA OF PARCEL:
45 SF
NEW IMPERVIOUS AREA:
1.PARKING REQUIREMENTS ARE UNCHANGED.
2.TRAFFIC IS UNAFFECTED.
3.SIGNAGE IS UNAFFECTED.
GENERAL INFORMATION:
ZONING
103.8' AGL
0.0' AGL
HIGHLINE WATER DISTRICT
23828 39TH AVENUE S
KENT, WA 98032
PROPERTY OWNER:
(47.351106° N)
(122.302468° W)
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH
REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
FROM T-MOBILE BOTHELL OFFICE:
·DEPART AND HEAD SOUTH ON N CREEK PKWY
·TURN RIGHT ONTO NE 195TH ST
·TAKE THE RAMP ON THE LEFT FOR I-405 S
·KEEP LEFT TO STAY ON I-405 S
·TAKE THE RAMP FOR I-5 SOUTH AND HEAD TOWARD PORTLAND
·AT EXIT 147, HEAD ON THE RAMP RIGHT AND FOLLOW SIGNS
FOR S 272ND ST
·TURN LEFT ONTO S 272ND ST
·BEAR RIGHT ONTO MILITARY RD S
·TURN RIGHT ONTO S 280TH PL, THEN IMMEDIATELY TURN RIGHT
ONTO 26TH AVE S
·TURN RIGHT ONTO 25TH PL S
·ARRIVE AT 25TH PL S
DRIVING DIRECTIONS
VICINITY MAP
NOT TO SCALE
GENERAL LOCATION MAP
NOT TO SCALE
PROJECT
PROJECT
APPROVED BY
DEVELOPMENT MANAGER
RF ENGINEER
DATE SIGNATURE
REGULATORY
OPERATIONS MANAGER
APPLICANT:
T-MOBILE USA, INC.
19807 NORTH CREEK PKWY N
BOTHELL, WA 98011
PHONE: (425) 641-1140
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
SE04227A
HERITAGE WOODS PARK-HGHLN WTR DT - SE52XC241 - SPRINT RETAIN
SITE NUMBER:
SITE NAME:
SITE LOCATION:
STRUCTURE TYPE: WATER TANK
47° 21' 03.98" N
122° 18' 08.89" W
(47.351106° N)
(122.302468° W)
LAT:
LONG:
THE INFORMATION CONTAINED IN THIS SET OF
CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.
ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
RELATES TO T-MOBILE USA, INC. SERVICES IS STRICTLY
PROHIBITED.
PROPRIETARY INFORMATION
REDONDO HEIGHTS UNREC SWLY 280 FT AND VAL OF
UNDEEDED STS & ALLEYS INCL IN ADJ LOT VAL
LEGAL DESCRIPTION
UTILITY COMPANIES
TBD
FIBER:
PUGET SOUND ENERGY
PHONE: (888) 225-5773
POWER:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL
DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND
OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE
SUPERSEDED BY THE LATEST REVISION.
LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF TOWER
MOUNTS FOR EXISTING OR PROPOSED LOADING. CONTRACTOR
AND MOUNT MANUFACTURER TAKE FULL RESPONSIBILITY FOR
MOUNTING PRODUCTS USED & THEIR ADEQUACY. MOUNTS SHOWN
IN DRAWINGS ARE FOR ILLUSTRATIVE PURPOSES ONLY.
DISCLAIMERS
PROJECT DESCRIPTION
T-MOBILE PROPOSES TO REPLACE (6) PANEL ANTENNAS, (3)
RRUS AND ADD (3) RRUS ON (2) PROPOSED CUSTOM TRIPOD
STAND ON AN EXISTING WATER TANK. REPLACE (2) CABINETS
ON SLAB AT GRADE. ALSO, INSTALLATION OF 40kW DIESEL
GENERATOR W/ TANK VENT ON CONCRETE PAD.
PROJECT CONSULTANT:
LDC, INC.
CONTACT: RICHARD B. HALL, AIA
PHONE: (425) 806-1869
EMAIL: rhall@ldccorp.com
PROJECT ARCHITECT:
PROJECT MANAGER:
T-MOBILE USA, INC.
CONTACT: DANIELLE SIERRA
EMAIL: Danielle.Costa@t-mobile.com
CONSTRUCTION MANAGER:
LDC, INC.
CONTACT: WALT DARBY
PHONE: (425) 279-3533
EMAIL: wdarby@ldccorp.com
LDC, INC.
20210 142ND AVE NE
WOODINVILLE, WA 98072
DRAWING INDEX
DWG. NO.DESCRIPTION
T-1.0 TITLE SHEET
G-1.0 GENERAL NOTES
A-1.0 SITE PLAN
A-2.0 ENLARGED SITE PLAN
A-2.1 EQUIPMENT PLAN
A-2.2 ANTENNA CONFIGURATION PLAN
A-3.0 ELEVATIONS
A-4.0 SITE PLAN LAYOUT
A-4.1 CABINET DETAILS
A-4.2 CABINET DETAILS
A-5.0 EQUIPMENT DETAILS
A-5.1 EQUIPMENT DETAILS
A-5.2 EQUIPMENT DETAILS
A-5.3 EQUIPMENT DETAILS
A-5.4 EQUIPMENT DETAILS
A-6.0 SIGNAGE DETAILS
S-1.0 STRUCTURAL NOTES & SPECIAL INSPECTIONS
S-2.0 STRUCTURAL DETAILS
S1.1 STRUCTURAL NOTES
S2.1 SITE PLAN
S3.1 ENLARGED SITE PLAN, SLAB PLAN & DETAILS
M-1.0 DIESEL GENERATOR SPECIFICATIONS
M-2.0 DIESEL GENERATOR SPECIFICATIONS
M-3.0 DIESEL GENERATOR SPECIFICATIONS
RF-1.0 RF PLUMBING DIAGRAM
RF-1.1 SFP DETAIL
E-1.0 ELECTRICAL SITE PLAN
E-2.0 SCHEMATIC GROUNDING PLAN
E-2.1 ELECTRICAL DIAGRAMS
E-2.2 ELECTRICAL DIAGRAMS
E-3.0 GROUNDING DETAILS
LDC, INC.
CONTACT: RICQUEL CARDOZA
PHONE: (206) 713-1626
EMAIL: ricquelc@ldccorp.com
SITE ACQUISITION:
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PROPOSED T-MOBILE BATTERY BACK-UP EQUIPMENT RACKS &
CABINETS TO BE REPLACED AND/OR UPGRADED WITH PROPOSED
ELECTROLYTE VOLUME COMPRISING OF LESS THAN 50 GALLONS.
FIRE REVIEW BATTERY ELECTROLYTE NOTE:
GENERAL NOTES
G-1.0
1.THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SEWER SERVICE.
2.THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION (NO HANDICAP
ACCESS IS REQUIRED)
3.OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER
MONTH, BY T-MOBILE TECHNICIANS.
4.NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL.
5.OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED.
6.ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE LATEST
VERSION.
7.THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE SCOPE OF
THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM WILL BE PAID FOR
EXPENSES RESULTING FROM FAILURE TO DO SO.
8.IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE
CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONSTRUCTION
MANAGER.
9.CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS,
ELECTRICAL LINES, AND ANTENNA CABLES.
10.ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS, ETC. IS INDICATED AT PROPOSED LOCATIONS ONLY.
CONFIRM THE EXACT ROUTING WITH THE ON-SITE CONSTRUCTION MANAGER PRIOR TO THE START OF
WORK.
11.ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE
PRE-CONSTRUCTION CONDITION OR BETTER.
12.INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE A MINIMUM OF 72
HOURS NOTICE TO CONSULTANT.
13.REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION OF THE
CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY THE
CONSTRUCTION MANAGER.
14.OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION OF
WORK AND ACCEPTANCE. PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER VERIFYING THAT
THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND AUTHORITIES HAVING JURISDICTION.
15.PROVIDE T-MOBILE WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER DATE OF
ACCEPTANCE. FOR THE COMPLETE INSTALLATION REPAIR OR REPLACE ANY DEFECTS ARISING DURING
THIS PERIOD AT NO EXTRA COST TO T-MOBILE.
16.NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED WITHOUT WRITTEN APPROVAL
FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT IN CONTRACTOR CORRECTING
THE INSTALLATION AT THEIR EXPENSE.
17.THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, REGULATIONS AND SAFETY
REGULATIONS, ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY
COMPANIES' REGULATIONS AND DIRECTIVES.
18.THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK. EXACT
DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR IS TO VERIFY THE
DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE. ANY
MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DO NOT EXCUSE THE
CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE
INTENT OF THESE DOCUMENTS.
19.VERIFICATION THAT EXISTING 103.8' WATER TANK CAN SUPPORT THE PROPOSED ANTENNA, COAX AND
ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS.
20.ANTENNA AZIMUTHS SHOWN ON THESE DRAWINGS ARE BASED ON TRUE NORTH. ALL AZIMUTHS MUST BE
VERIFIED WITH THE CORRECT SMR PRIOR TO CONSTRUCTION.
GENERAL NOTES:ABBREVIATIONS:
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
ALUM ALUMINUM
AB ANCHOR BOLT
∠ANGLE
ARCH ARCHITECTURAL
BTS BASE TRANSMISSION SYSTEM
BLDG BUILDING
BM BEAM
BOT BOTTOM
B.O.BOTTOM OF
BOC BOTTOM OF CONCRETE
BOS BOTTOM OF STEEL
CJ CONTROL JOINT
℄CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CTR CENTER
DIA / Ø DIAMETER
DTL DETAIL
(E)EXISTING
EA EACH
EJ EXPANSION JOINT
ELEC ELECTRIC/ELECTRICAL
EL ELEVATION
EQ EQUAL
EW EACH WAY
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FHFB FLEXI RRH 4-PIPE 1900
FIN FINISH
FIN FLR FINISH FLOOR
FLR FLOOR
FSMF FLEXI MULTIRADIO SYSTEM MODULE
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GYP GYPSUM
GB GYPSUM BOARD
HM HOLLOW METAL
HOR HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING VENTILATION AIR CONDITIONING
INSUL INSULATION
INT INTERIOR
JT JOINT
LAM LAMINATED
LF LINEAL FOOT
MANUF MANUFACTURER
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MM MILLIMETER
MIN MINIMUM
MISC MISCELLANEOUS
MPH MILES PER HOUR
MTL METAL
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
PCS PERSONAL COMMUNICATION SYSTEM
⅊PLATE
PR PAIR
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PT PRESSURE TREATED
RAD RADIUS
RD ROOF DRAIN
REINF REINFORCED/REINFORCING
REQ'D REQUIRED
RM ROOM
R/W RIGHT OF WAY
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SIM SIMILAR
SQ FT SQUARE FOOT
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRUC STRUCTURAL
TEMP TEMPORARY
THK THICK
TMA TOWER MOUNTED ANTENNA
T.O.TOP OF
TOS TOP OF STEEL
TOC TOP OF CONCRETE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/WITH
WWM WELDED WIRE MESH
LEGEND AND SYMBOLS:
CHAIN LINK FENCE
CEDAR FENCE
POWER
UNDERGROUND POWER
TELCO
UNDERGROUND TELCO
OVERHEAD POWER
BOUNDARY
CENTERLINE
REVISION BUG
ELEVATION
DETAIL NUMBER
SHEET NUMBER
SECTION CUT
PROPOSED ELEVATION
0'-0" AGL
X
X-X
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROM
PREVIOUS PLAN SETS OR FROM ASSESSORS MAPS. LDC HAS NOT
COMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIM AS
TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET.
1SITE PLAN
22"x34" SCALE: 1" = 30'11"x17" SCALE: 1" = 60'
EXISTING SITE ACCESS
SITE PLAN
A-1.0
PROPOSED T-MOBILE ANTENNA
MOUNTED TO PROPOSED CUSTOM
TRIPOD STAND ON AN EXISTING
103.8' WATER TANK
PROPOSED T-MOBILE EQUIPMENT
ON SLAB AT GRADE
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
1
A-2.0
ZONING:
RS7.2 (SINGLE FAMILY RESIDENTIAL)
ADJACENT ZONING:
RS7.2 (SINGLE FAMILY RESIDENTIAL)
EXISTING FENCED
COMPOUND
183'-0
"
ANTE
N
N
A
S
E
T
B
A
C
K
80'-0"
ANTE
N
N
A
S
E
T
B
A
C
K
11
4
'
-0
"ANTENNA SETBACK
163
'
-
0
"ANTENNA SETBACK
EXISTING SITE
ACCESS GATES
PROPOSED T-MOBILE 40kW DIESEL
GENERATOR W/ TANK VENT ON
CONCRETE PAD (1 TOTAL)
ENLARGED SITE PLAN
A-2.01PROPOSED ENLARGED SITE PLAN
22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0"
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
ALL
A-2.1
ALL
A-2.2
PROPOSED T-MOBILE ANTENNA
MOUNTED ON PROPOSED
CUSTOM TRIPOD STAND AN
EXISTING 103.8' WATER TANK
PROPOSED T-MOBILE EQUIPMENT
ON SLAB AT GRADE
EXISTING 103.8' WATER TANK
PROPOSED T-MOBILE HYBRID
CABLE ROUTE TO FOLLOW
EXISTING CABLE CONDUIT
ROUTING FROM TOWER BASE TO
TOP OF TOWER
PROPOSED T-MOBILE 40kW DIESEL
GENERATOR W/ TANK VENT ON
CONCRETE PAD (1 TOTAL)
ALL
A-3.0
EXISTING CABLE JUNCTION
BOXES (TO REMAIN)
1EXISTING EQUIPMENT PLAN
EQUIPMENT PLAN
A-2.12PROPOSED EQUIPMENT PLAN
22"x34" SCALE: 3/4" = 1'-0"11"x17" SCALE: 3/8" = 1'-0"
NOTE:
·UPGRADE/REPLACE STANDARD PIPE(S) AS NEEDED
·GC TO VERIFY EXISTING ALL THREADS AND
COLLARS TO BE CHECKED DURING CONSTRUCTION
FOR WEAR AND TEAR AND IF FOUND TO HAVE ANY
ISSUES, PLEASE REPORT AND PROVIDE PICTURES
TO THE TMO CM.
·RF MODULES ADDED WITHIN CABINET: (2) ASIB, (2)
ASIK, (1) FSMF, (3) ABIA, (6) ABIL, (3) ABIC AND (2)
AMIA
·REMAINING EXISTING SPRINT EQUIPMENT TO
REMAIN OPERATIONAL FOR PROPOSED T-MOBILE
USE
12” THICK DOWNTURNED SLAB W/ 18” DEEP X 18” WIDE DEEP
EDGE CONDITION SHALL BE CONSTRUCTED W/ 4500 PSI
MAXIMUM W/C RATIO OF 0.45 AND 5%-6% AIR ENTRAINMENT
PER ACI W/ #4 AT 12” O.C. MINIMUM BOTH DIRECTIONS
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
CONSTRUCTION PLAN KEYED NOTES
EXISTING EQUIPMENT CONCRETE PAD (TO REMAIN).
EXISTING SPRINT EQUIPMENT CABINET (2 TOTAL TO BE REMOVED).
EXISTING 200A METER BASE ON POST (TO REMAIN).
EXISTING SPRINT HYRBID CABLE ROUTE (TO BE REMOVED).
EXISTING SPRINT UTILITY H-FRAME WITH POWER AND
TELCO CABINET (TO REMAIN).
EXISTING JUNCTION BOX (2 TOTAL, TO REMAIN).
EXISTING SPRINT GPS ANTENNA (TO BE REMOVED).
PROPOSED T-MOBILE MODULES MOUNTED WITHIN PROPOSED
CABINET (SEE NOTE FOR MODULES & QUANTITIES).
PROPOSED T-MOBILE HCS 2.0 (TYP 2 JUNCTION
BOXES @ EQUIPMENT W/ 9 HYBRID FIBER JUMPERS).
PROPOSED T-MOBILE GPS ANTENNA MOUNTED TO EXISTING
H-FRAME POST (1 TOTAL).
PROPOSED T-MOBILE 40kW DIESEL GENERATOR
W/ TANK VENT ON CONCRETE PAD (1 TOTAL).
PROPOSED T-MOBILE ATS CABINET MOUNTED TO EXISTING
H-FRAME.
PROPOSED T-MOBILE (2) 4"Ø SCHD 40 PVC CONDUITS FOR POWER &
ALARM CONTROL FROM GENERATOR TO ATS.
PROPOSED T-MOBILE PURCELL HPL3 600A DC SITE SUPPORT
CABINET (1 TOTAL).
PROPOSED T-MOBILE PURCELL LB3 BATTERY
CABINET (1 TOTAL).
8
9
10
11
12
13
14
22
25
27
28
29
30
31
32
1.VERIFY ANTENNA MODELS, HEIGHTS & AZIMUTHS.
2.ANALYSIS OF WATER TANK SHALL BE PERFORMED BY OTHERS AND
STAMPED BY A LICENSED STRUCTURAL ENGINEER.
3.PROPOSED ANTENNAS, EQUIPMENT AND MOUNTING HARDWARE
NEAR ANTENNA LEVEL SHALL BE PAINTED TO MATCH EXISTING.
4.KEEP ALL EQUIPMENT CLEAR OF CLIMBING LINE. IF SAFETY CLIMB
LINE IS OBSTRUCTED, SITE MAY REQUIRE MAN LIFT OR CRANE.
SITE NOTES
FUTURE T-MOBILE EXPANSION CABINET.33
ALL
A-5.0
3,5,6
A-5.3
ALL
A-4.0
ALL
A-4.0
ALL
A-5.1
1
A-4.1
1
A-4.2
1
M-1.0
1
M-3.0
2
A-5.4
TO 1
S-1.0
5
S-2.0
1
A-5.2
10
14
813
10'-0"5'-0"5'-0"
10'-0"9'-0"28
31
32
22
10
11
1210'-0"10'-0"
29
30
13
11
25
9
25 (2 STACKED)
9
27
PROPOSED 2" RIGID CONDUIT
(4) TOTAL, FROM HPL3 CABINET,
TO (E) PANEL, (E) TELCO
CABINET AND JUNCTION BOXES
22"x34" SCALE: 3/4" = 1'-0"11"x17" SCALE: 3/8" = 1'-0"
33
ANTENNA CONFIGURATION PLAN
A-2.2
S
E
C
T
O
R
3
:
3
1
0
°
1EXISTING ANTENNA CONFIGURATION PLAN 2PROPOSED ANTENNA CONFIGURATION PLAN
NOTE:
·UPGRADE/REPLACE STANDARD PIPE(S) AS NEEDED
·GC TO VERIFY EXISTING ALL THREADS AND
COLLARS TO BE CHECKED DURING CONSTRUCTION
FOR WEAR AND TEAR AND IF FOUND TO HAVE ANY
ISSUES, PLEASE REPORT AND PROVIDE PICTURES
TO THE TMO CM.
22"x34" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
PROPOSED T-MOBILE ANTENNA CONFIGURATION
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER
ANTENNA
SIZE
MECH.
TILT QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
1
1 140°FFVV-65C-R3-V1 106.0'95.9"0°
1 AHLOA 1
HYBRID
JUMPER 200'1 AHFIG
1 140°AEHC 106.0'38.2"0°
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER
ANTENNA
SIZE
MECH.
TILT QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
2
1 220°FFVV-65C-R3-V1 106.0'95.9"0°
1 AHLOA
1 AHFIG
1 220°AEHC 106.0'38.2"0°
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER
ANTENNA
SIZE
MECH.
TILT QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
3
1 310°FFVV-65C-R3-V1 106.0'95.9"0°
1 AHLOA
1 AHFIG
1 310°AEHC 106.0'38.2"0°
TASK SUBMITTED ON:02/19/21 9 TOTAL HYBRID
JUMPERS
EXISTING SPRINT ANTENNA CONFIGURATION
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
1 1 340°APXVBBLL15X_43-C-120 105.0'1 RADIO 1 HYBRID 175'
TASK SUBMITTED ON:02/19/2021 8 175'
22"x34" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
1 100°105.0'
SECTOR ANTENNA
QUANTITY AZIMUTH ANTENNA MODEL RAD
CENTER QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
1 220°105.0'1 RADIO 1 175'
MICROWAVE AZIMUTH MICROWAVE MODEL RAD
CENTER QUANTITY EQUIPMENT
TYPE
CABLE
QUANTITY TYPE LENGTH
MW 1 -UNKNOWN -1 175'
MW 2 -UNKNOWN -1 175'
MW 3 -UNKNOWN -1 175'
MW 4 -UNKNOWN -1 175'
MW 5 -UNKNOWN -1 175'
HYBRID
COAX
COAX
COAX
COAX
COAX
COAX/HYBRID
EXISTING 103.8' WATER
TANK (TO REMAIN).SECTOR 1
: 340°
1 340°TTTT65AP-1XR 105.0'
2 1 100°105.0'1 RADIO 1 HYBRID 175'
3
1 220°105.0'SECTOR 3 : 220°SECTOR
2
:
1
0
0
°
EXISTING SPRINT ANTENNA
MOUNTING PLATFORM (1
TOTAL REMAIN).
EXISTING SPRINT PANEL ANTENNA
(6 TOTAL TO BE REMOVED).
EXISTING TRIPOD MOUNT (4 TOTAL,
TO REMAIN)
EXISTING SPRINT RADIO UNIT (3
TOTAL @ ANTENNA TO BE
REMOVED).
EXISTING MICROWAVE (5
TOTAL TO REMAIN).
EXISTING SPRINT HYRBID
CABLE ROUTE (TO BE
REMOVED).
EXISTING 103.8' WATER
TANK (TO REMAIN).
EXISTING SPRINT ANTENNA
MOUNTING PLATFORM (1
TOTAL REMAIN).
EXISTING MICROWAVE (5
TOTAL TO REMAIN).
PROPOSED T-MOBILE DUAL
ANTENNA MOUNT (TYP 1 PER
SECTOR, 3 TOTAL).
PROPOSED T-MOBILE AEHC
PANEL ANTENNA (TYP 1 PER
SECTOR, 3 TOTAL, SEE NOTE).
PROPOSED T-MOBILE
AHFIG RADIO UNIT (TYP 1
PER SECTOR, 3 TOTAL).
PROPOSED T-MOBILE
AHLOA RADIO UNIT (TYP 1
PER SECTOR, 3 TOTAL).
PROPOSED T-MOBILE
FFVV-65C-R3-V1 PANEL
ANTENNA (TYP 1 PER SECTOR,
3 TOTAL, SEE NOTE).
APXVBBLL15X_43-C-120
TTTT65AP-1XR
APXVBBLL15X_43-C-120
TTTT65AP-1XR
SECTOR
1
:
1
4
0
°SECTOR 2 : 220°EXISTING TRIPOD MOUNT (4 TOTAL,
TO REMAIN)
PROPOSED T-MOBILE
CUSTOM TRIPOD PER
STRUCTURAL (2 TOTAL).
5'-0"
4'-0"5'-0"1
1
1
1
1
1
1
1
HYBRID
JUMPER 200'
HYBRID
JUMPER 200'
ELEVATIONS
A-3.01EXISTING NORTH ELEVATION (LOOKING SOUTH)
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/16" = 1'-0"2PROPOSED NORTH ELEVATION (LOOKING SOUTH)
FINISH GRADE
0.0' AGL
22"x34" SCALE: 1/8" = 1'-0"11"x17" SCALE: 1/16" = 1'-0"
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
CONSTRUCTION PLAN KEYED NOTES
PROPOSED T-MOBILE AHFIG RADIO UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
EXISTING EQUIPMENT CONCRETE PAD (TO REMAIN).
EXISTING SPRINT EQUIPMENT CABINET (2 TOTAL TO BE REMOVED).
EXISTING 200A METER BASE ON POST (TO REMAIN).
PROPOSED T-MOBILE DUAL ANTENNA
MOUNT (TYP 1 PER SECTOR, 3 TOTAL).
PROPOSED T-MOBILE CUSTOM TRIPOD PER
STRUCTURAL (2 TOTAL).
EXISTING SPRINT ANTENNA MOUNTING PLATFORM
(1 TOTAL REMAIN).
EXISTING MICROWAVE (5 TOTAL TO REMAIN).
EXISTING SPRINT HYRBID CABLE ROUTE (TO BE REMOVED).
EXISTING SPRINT UTILITY H-FRAME WITH POWER AND
TELCO CABINET (TO REMAIN).
PROPOSED T-MOBILE AHLOA RADIO UNIT
(TYP 1 PER SECTOR, 3 TOTAL).
EXISTING SPRINT GPS ANTENNA (TO BE REMOVED).
PROPOSED T-MOBILE MODULES MOUNTED WITHIN PROPOSED
CABINET (SEE NOTE FOR MODULES & QUANTITIES).
PROPOSED T-MOBILE FFVV-65C-R3-V1 PANEL ANTENNA
(TYP 1 PER SECTOR, 3 TOTAL, SEE NOTE).
EXISTING SPRINT ANTNNA TRIPOD MOUNT (4 TOTAL, TO REMAIN).
EXISTING SPRINT PANEL ANTENNA (6 TOTAL TO BE REMOVED).
EXISTING SPRINT RADIO UNIT (3 TOTAL @ ANTENNA
TO BE REMOVED)
PROPOSED T-MOBILE HCS 2.0 (TYP 2 JUNCTION
BOXES @ EQUIPMENT W/ 9 HYBRID FIBER JUMPERS).
EXISTING 103.8' WATER TANK (TO REMAIN)
PROPOSED T-MOBILE 40kW DIESEL GENERATOR
W/ TANK VENT ON CONCRETE PAD (1 TOTAL).
PROPOSED T-MOBILE AEHC PANEL ANTENNA (TYP 1 PER
SECTOR, 3 TOTAL, SEE NOTE).
PROPOSED T-MOBILE PURCELL HPL3 600A DC SITE SUPPORT
CABINET (1 TOTAL).
PROPOSED T-MOBILE PURCELL LB3 BATTERY
CABINET (1 TOTAL).
1
2
3
4
5
6
8
9
10
12
13
14
15
16
17
18
19
20
22
25
28
31
32
1.VERIFY ANTENNA MODELS, HEIGHTS & AZIMUTHS.
2.ANALYSIS OF WATER TANK SHALL BE PERFORMED BY OTHERS AND
STAMPED BY A LICENSED STRUCTURAL ENGINEER.
3.PROPOSED ANTENNAS, EQUIPMENT AND MOUNTING HARDWARE
NEAR ANTENNA LEVEL SHALL BE PAINTED TO MATCH EXISTING.
4.KEEP ALL EQUIPMENT CLEAR OF CLIMBING LINE. IF SAFETY CLIMB
LINE IS OBSTRUCTED, SITE MAY REQUIRE MAN LIFT OR CRANE.
SITE NOTES
6
A-5.4
1
A-5.3
2
A-5.3
4
A-5.2
2
A-5.2
ALL
A-5.0
3,5,6
A-5.3
ALL
A-4.0
ALL
A-4.0
ALL
A-5.1
1
A-4.1
1
A-4.2
1
M-1.0
1
M-3.0TO 1
S-1.0
5
S-2.0
1,5,6
S-3.1
TOP OF EXISTING WATER TANK
103.8' AGL
TIP HEIGHT OF EXISTING SPRINT ANTENNAS
108.7' AGL
FINISH GRADE
0.0' AGL
TOP OF EXISTING WATER TANK
103.8' AGL
TIP HEIGHT OF PROPOSED T-MOBILE ANTENNAS
110.0' AGL
RAD CENTER OF PROPOSED T-MOBILE ANTENNAS
106.0' AGL
3
4
6
2
5
1
10
12
14
9
16
20
6
2
5
1
31
25
28
32
22
9
18
17
NOTE:
·UPGRADE/REPLACE STANDARD PIPE(S) AS NEEDED
·GC TO VERIFY EXISTING ALL THREADS AND
COLLARS TO BE CHECKED DURING CONSTRUCTION
FOR WEAR AND TEAR AND IF FOUND TO HAVE ANY
ISSUES, PLEASE REPORT AND PROVIDE PICTURES
TO THE TMO CM.
·RF MODULES ADDED WITHIN CABINET: (2) ASIB, (2)
ASIK, (1) FSMF, (3) ABIA, (6) ABIL, (3) ABIC AND (2)
AMIA
·REMAINING EXISTING SPRINT EQUIPMENT TO
REMAIN OPERATIONAL FOR PROPOSED T-MOBILE
USE
15
19
8 13
14
13
28
7'-3" WORKING CLEARANCE
PROPOSED PURCELL
HPL3 LARGE
BATTERY CABINET
PROPOSED PURCELL HPL3
600A DC CABINET (BEYOND)
CORRECT KNOCKOUT TOOL REQUIRED
FOR PUNCHING KNOCKOUTS. DO NOT
DRILL KNOCKOUTS THROUGH
2'-6"2'-6"6'-4" VERTICAL CLEARANCEPURCELL HPL3
LARGE BATTERY
CABINET
PURCELL
HPL3 600A DC
CABINET
5'-0"6'-2"10"11"
6'-9" WORKING CLEARANCE
2"
SKU# 34038 PURCELL 2" PLINTH
(REQUIRED)
2 CABINET CONFIGURATION -
PURCELL HPL3 600A DC CABINET &
PURCELL HPL3 LARGE BATTERY CABINET
2'-6"
5'-0"
PURCELL HPL3
LARGE BATTERY
CABINET
PURCELL HPL3 600A
DC CABINET
7'-3" WORKING CLEARANCE2'-7"2'-7"10"2'-4"2'-4"11"
6'-9" WORKING CLEARANCE
2'-6"
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2SITE ELEVATION LAYOUT
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1SITE PLAN LAYOUT
SITE PLAN LAYOUT
A-4.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
72"8"32"8"28"28"
(4x) 5/8"Ø FOR
CABINET ANCHORAGE
(4x) 5/8"Ø FOR
BATTERY MOUNTING
CORRECT KNOCKOUT
TOOL REQUIRED FOR
PUNCHING KNOCKOUTS.
DO NOT DRILL
KNOCKOUTS THROUGH
FRONT VIEW
(OPEN)
(6) KNOCKOUTS LOCATED
INCONVENIENTLY FROM
INTERNAL AIRSCALE
EQUIPMENT & ARE NOT
FEASIBLE. SEE FIBER
ROUTE OPTION 1.
FIBER ROUTE OPTION
1: IT IS STRONGLY
RECOMMENDED TO
USE THESE (4)
KNOCKOUTS TO &
FROM COVP WITH
WATER-TIGHT LB OR
GROMMET
2 ROWS OF 4 2"
KNOCKOUTS INTENDED
FOR POWER, TELCO, &
BOTTOM FIBERS TO
COVP. ALL INCOMING
CABLING TO BE IN RIGID
OR FLEXIBLE CONDUIT
WITH AN LB.
FIBER ROUTE OPTION 2: REAR
KNOCKOUTS CAN BE UTILIZED
FOR BOTTOM FIBER ROUTING
FROM COVP TO AIRSCALE IF
OPTION 1 IS UNAVAILABLE.
ANY OF THE BOTTOM
KNOCKOUTS CAN BE
USED FOR THE AC
POWER FEED
KNOCKOUT FOR
ETHERNET FOR ALARMS
KNOCKOUTS FOR
BATTERY WIRES
BACK VIEWRIGHT VIEWFRONT VIEW
ISO VIEW
MOUNTING FOOTPRINT
PLAN VIEW
MANUFACTURER:PURCELL SYSTEMS INC
MODEL:HPL3 600A DC CABINET
WEIGHT:430 LBS (WITHOUT EQUIPMENT)
DIMENSIONS:30.0"x48.0"x72.0"
SKU# 34038 PURCELL 2" PLINTH
PLAN VIEW
SKU# 34038 PURCELL
2" PLINTH (OPTIONAL)
2"
SKU# 34038 PURCELL
2" PLINTH
SIDE VIEW
2'-6"2'-5"2"
4'-0"
RACK ASSIGNMENT
RACK RU SLOT DESCRIPTION
TOP15
3RD
AIRSCALE14
13
12
FIBER MUX
11
10
2ND
AIRSCALE9
8
7
FIBER MUX
6
5
1ST
AIRSCALE4
3
2
FIBER MUX
1
RECTIFIER SHELF
BOTTOM16 VOLTAGE
BOOSTER
15
CSR
14
13
4TH
AIRSCALE12
11
10 FIBER MUX
9
3RD LEGACY
BBU8
7
6
2ND LEGACY
BBU5
4
3
1ST LEGACY
BBU2
1
4X .75 Ø HOLES FOR HPL3
AND EXPANSION CABINET
CORNER MOUNTING
POINTS
4X .875 Ø HOLES FOR
HPL3 AND EXPANSION
CABINET 2-STRING
BATTERY RACK
MOUNTING POINTS
4X .875 Ø HOLES FOR
HPL3 4-STRING BATTERY
RACK MOUNTING POINT
SHIPPING HOOKS TO
BE REMOVED AFTER
CABINET INSTALL
40"
8"32"30"ALL DC POWER
CABLES (BLUE)
TO BE ROUTED
AT THE LEFT SIDE
OF THE CABINET
INTERNAL ROUTING
FIBER CABLES
(YELLOW)
19" RACK
ADAPTER
FIBER
KNOCKOUT
ALL FIBER
CABLES
(YELLOW) TO BE
ROUTED AT THE
RIGHT SIDE OF
THE CABINET
MOUNT FSEE
ON VERY
BOTTOM RU
POSITION OF
HPL# SSC
AND PLACED
IN THE FASB
TRAY
RAYCAP
VOLTAGE
BOOSTER
MOUNT
DIRECTLY
BENEATH THE
DC POWER
PLANT
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1SKU#33965 - PURCELL HPL3 600A DC POWER CABINET DETAIL
CABINET DETAILS
A-4.1
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
2'-712""30.00"5'-012""1'-11""1'-10""
(4x) 5/8"Ø FOR
CABINET ANCHORAGE
SHIPPING HOOKS TO
BE REMOVED AFTER
CABINET INSTALL
CORRECT KNOCKOUT
TOOL REQUIRED FOR
PUNCHING KNOCKOUTS.
DO NOT DRILL
KNOCKOUTS THROUGH
BATTERY
BRACKETS
4X BATTERY
SHELVES, UP
TO 200AH
BATTERY
VIBRATION
MOUNTS
KNOCKOUT FOR
ETHERNET FOR
ALARMS
KNOCKOUTS FOR
BATTERY WIRES
NOTE:
·WIRES RUN THROUGH PROVIDED KNOCKOUT.
FOLLOW PROPER INSTALLATION OF GASKET
BEFORE MATING THE 2 CABINETS
MANUFACTURER:PURCELL SYSTEMS INC
MODEL:HPL3 LARGE BATTERY CABINET
WEIGHT:350 LBS (WITHOUT EQUIPMENT)
DIMENSIONS:30.0"x31.6"x60.4"
SKU# 34038 PURCELL 2" PLINTH
(OPTIONAL)
0'-2""
SKU# 34038 PURCELL 2" PLINTH
PLAN VIEW
SKU# 34038 PURCELL 2" PLINTH
SIDE VIEW
2'-6""2'-5""2""
4X .75 Ø HOLES FOR HPL3 AND
EXPANSION CABINET CORNER
MOUNTING POINTS
4X .875 Ø HOLES FOR
HPL3 AND EXPANSION
CABINET 2-STRING
BATTERY RACK
MOUNTING POINTS
4X .875 Ø HOLES FOR
HPL3 4-STRING BATTERY
RACK MOUNTING POINT
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1SKU#33966 - PURCELL HPL3 LARGE BATTERY CABINET DETAIL
CABINET DETAILS
A-4.2
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
NOTE: REFER TO ALARM STANDARD FOR
INSTALLATION.
13.7"4.3"1.7"MANUFACTURER:NOKIA
MODEL:473751A
WEIGHT:1.5 LBS
DIMENSIONS:13.7"x4.3"x1.7"
EQUIPMENT DETAILS
A-5.0
PROPOSED ASIB LOCATED
WITHIN AMIA RACK 14.2"1.7"8.6"
MANUFACTURER:NOKIA
MODEL:ASIB
WEIGHT:6.4 LBS
DIMENSIONS:8.6"x14.2"x1.7"
SIN
EAC
SOUT
SEI1
SEI2
GROUNDING
SRIO1
EIF1
EIF2
EIF3 EIF5
EIF4 LMP
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 34104 ASIB DETAIL 1 22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 33388 - ABIA DETAIL
RF1 RF2 RF3 RF4 RF5 RF6
PROPOSED ABIA LOCATED
WITHIN AMIA RACK
8.6"14.2"1.1"MANUFACTURER:NOKIA
MODEL:ABIA
WEIGHT:4.6 LBS
DIMENSIONS:8.6"x14.2"x1.1"
2
PROPOSED ABIL LOCATED
WITHIN AMIA RACK
SFP28
QSFP28
S-RF1 S-RF2
S-RF1 S-RF2
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 33617 - ABIL DETAIL
MANUFACTURER:NOKIA
MODEL:ABIL
WEIGHT:4.4 LBS
DIMENSIONS:8.6"x14.2"x1.1"
3
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 34103 - ABIC DETAIL
MANUFACTURER:NOKIA
MODEL:ABIC
WEIGHT:5.8 LBS
DIMENSIONS:8.6"x14.2"x1.7"
RF1
RF2
RF3 RF5 RF7 RF9
RF4 RF6 RF8
4 22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
PROPOSED ASIK LOCATED
WITHIN AMIA RACK 14.2"1.7"8.6"
MANUFACTURER:NOKIA
MODEL:ASIK
WEIGHT:6.6 LBS
DIMENSIONS:8.6"x14.2"x1.7"
FAN
LMP
SEI EIF1 EIF2STATUS
SKU# 33615 - ASIK DETAIL 6
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.5SKU# 33846 - FSEE FLEXI SYSTEM EXTERNAL ALARM BOARD
MANUFACTURER:ALCATEL-LUCENT
MODEL:3HE15546AA
WEIGHT:10.5 LBS (FULLY LOADED)
DIMENSIONS:1.75"x17.25"x10"
20-60 VDC 15A
DCINPUT+12V
DC PSU250W
20-60 VDC 15A
DCINPUT+12V
DC PSU250W
PS1 PS2 NOKIA 7250 IXR-E 24SFP + 8SFP28 2QSFP28 Reset SDCard PS2PS1 Stat Fan LOC USB MgmtConsole
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
1PPS
SFP/SFP+ 10Gpbs
PORTS 1-24
SFP28/SFP+ 25Gpbs
PORTS 25-32
QSFP28
100Gpbs
PORTS 33-34
USB Mgmt
Console
GROUNDING
MANAGEMENTS
USB
CONSOLE
FRONT VIEW
REAR VIEW
GPS SFP
BAIL
SMA-F CONNECTOR
FOR GPS ANTENNA
RP-MMCX CONNECTOR
FOR 1PPS OUTPUT
DC PSU
DC PSU
SD CARD SLOT AIR FILTER TRAY
17.25"1.75"10"
EQUIPMENT DETAILS
A-5.122"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
NOT USED 4
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 33389 - AMIA DETAIL
MANUFACTURER:NOKIA
MODEL:AMIA
WEIGHT:11.2 LBS (UNIT ONLY)
DIMENSIONS:5.1"x15.7"x17.6"
1 22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 32246 - FSMF DETAIL
DC OUTPUT
DC INTPUT
LMP
EIF2/RF/EXT6 RF/EXT1-3 EIF1
SRIO
BB EX 1-2
EAC
SYNC IN
SYNC OUT
OPTIONAL POWER
DISTRIBUTION
SUB-MODULE
OPTIONAL CAPACITY
EXTENSION SUB-MODULE
OPTIONAL TRANSPORT
SUB-MODULE
MANUFACTURER:NOKIA
MODEL:FSMF
WEIGHT:25.3 LBS
DIMENSIONS:5.2"x17.6"x16.5"
NOTE:
FSMF SHALL BE PLACED
WITHIN RADIO CABINET PER
T-MOBILE REQUIREMENTS
SIDE TOP
17.6"5.2"16.5"2 22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.3SKU# 34097 CSR - IXR-E ROUTER GEN 2
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
NOT USED 622"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
NOT USED 5
FIGURE:
FIXING UPPER MOUNTING
BRACKET (FPKA)
FIGURE:
FIXING LOWER POLE MOUNTING
BRACKET (FPKA) USING TWO M8 SCREWS
FIGURE:
FIXING LOWER MOUNTING
BRACKET (FPKA) ONTO A POLE
NOTES:
·PROPOSED RRUS TO BE MOUNTED VERTICALLY ONLY
·MOUNTING PIPE NOT SHOWN FOR CLARITY
MANUFACTURER:NOKIA
MODEL:FPKA MOUNT
WEIGHT:3.3 LBS
DIMENSIONS:10.8"x9.0"x1.9"
BOLT M10x120
105mm THREAD
BOLT
M8x120
BOLT
RESTRAINER
FPKA
MOUNTING
BRACKET
1.9"9.
0
"
10.8"
PROPOSED FPKA
MOUNTING
BRACKET
PROPOSED
RRUS
PROPOSED RRUS
1/2''Ø COAX CABLE, 5'' MIN
BENDING RADIUS
#2 AWG, GROUND WIRE
GROUNDING KIT
H-FRAME POST
VALMONT MICROFLECT UNIVERSAL PIPE
ADAPTER KIT (PART NO. B1534)
1-1/4'' NOMINAL Ø (1.66" ACTUAL O.D.)
x 2'-0'' MAX SCH 40 GALV STEEL
MOUNTING PIPE (SEE NOTE 4)
GPS ANTENNA
NOTES:
1.LOCATION OF ANTENNA MUST HAVE CLEAR VIEW OF SOUTHERN SKY AND CANNOT HAVE ANY BLOCKAGES
EXCEEDING 25% OF THE SURFACE AREA OF A HEMISPHERE AROUND THE GPS ANTENNA.
2.ALL GPS ANTENNA LOCATIONS MUST BE ABLE TO RECEIVE CLEAR SIGNAL FROM A MINIMUM OF FOUR (4)
SATELLITES. VERIFY WITH HANDHELD GPS BEFORE FINAL LOCATION OF GPS ANTENNA.
3.THE WEIGHT OF THE ANTENNA MOUNT - 6.5 LBS.
4.IF ICE BRIDGE OR SIMILAR POST IS NOT GROUNDED, PROVIDE GROUNDING WITH #2 AWG TINNED BARE
COPPER WIRE EXOTHERMICALLY BONDED TO LOWER PART OF POST AND CONNECTED TO GROUND RING.
FRONT SIDEISO
BOTTOM
12.9"28.7"5.6"
MANUFACTURER:NOKIA
MODEL:475125A
DIMENSIONS:28.7"x12.9"x5.6" (W/ MOUNTING
BRACKETS AND COVER)
WEIGHT:70.5 LBS
FREQUENCY:B25, B66
GND
DC IN OPT 1 OPT 2 RET EAC
ANT 1 ANT 2 ANT 3 ANT 4 EQUIPMENT DETAILS
A-5.25AHFIG MOUNTING DETAIL
22"x34" SCALE: 1" = 1'-0"11"x17" SCALE: 1/2" = 1'-0"
3SKU# 31685 - FPKA POLE MOUNTING KIT
22"x34" SCALE: 1" = 1'-0"11"x17" SCALE: 1/2" = 1'-0"22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2 AHLOA DETAIL
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1GPS ANTENNA DETAIL
DCIN
OPT1
OPT2
RET
EAC
GND
ANT1
ANT2 ANT3
ANT4
MANUFACTURER: NOKIA
MODEL:AHLOA
WEIGHT: 83.8 LBS
DIMENSIONS: 22.0"x7.4"x12.1"
ISO BOTTOM
4SKU# 34073 - AHFIG DETAIL
22"x34" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PIPE
1/4"Ø GALV BOLT
(TYP OF 8 PER COVP
MOUNTING BRACKET)
3/8"Ø GALV U-BOLT
1/4"Ø GALV BOLT
(TYP OF 4 PER COVP)TOP
RIGHT SIDE
FIBER
FIBER
6 AWG
6 AWG
6 AWG
6 AWG
FIBER
FIBER
6 AWG
6 AWG
(12) - #6 AWG CLASS C
(4) - 12 FOC LOOSE
TUBE SINGLE MODE
FLAME RESISTANT
NON-HYGROSCOPIC
FILLERS (AS NEEDED).
MYLAR BINDER TAPE.
5-MIL THICK BARE
COPPER SHIELD
80 MILS (2.03 MM) OF
(PVC) JACKET
RIPCORD1.48"6 AWG 6 AWG
6 AWG6 AWG
6 AWG 6 AWG
HYBRID CABLE
STRUCTURE
WATER TANK
LENGTH
2 300'±
# OF
CABLES
MANUFACTURER:COMMSCOPE
MODEL:FE-16148-OVP-RT12
WEIGHT:23.5 LBS
DIMENSIONS:14.0"x16.0"x8.0"
MOUNTING KIT:PROVIDED
MANUFACTURER:COMMSCOPE
MODEL:FE-16148-OVP-RT12
WEIGHT:23.5 LBS
DIMENSIONS:14.0"x16.0"x8.0"
MOUNTING KIT:PROVIDED
EQUIPMENT DETAILS
A-5.36HI-CAP BOX MOUNTING DETAIL
22"x34" SCALE: 3/4" = 1'-0"_1 11"x17" SCALE: 1 1/2" = 1'-0"
3HCS 2.0 HI-CAP TRUNK DETAIL
22"x34" SCALE: 3/4" = 1'-0"_1 11"x17" SCALE: 1 1/2" = 1'-0"
5SKU# 33702 HI-CAP JUNCTION BOX
22"x34" SCALE: 2" = 1'-0"11"x17" SCALE: 1" = 1'-0"22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
NOT USED 4
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SKU# 34117 - AEHC DETAIL
MANUFACTURER:NOKIA
MODEL:AEHC
WEIGHT:108.0 LBS
DIMENSIONS:38.2"x21.5"x5.9"
FREQUENCY:B41
5.9"19.7"
21.5"5.1"EAC
BOTTOM
DC IN
RET
OPT4
OPT1
OPT2
TOP
38.2"ISO
GND
OPT3
NOKI
A
OPT1 OPT2 OPT3 OPT4 RET
BAC
FRONT SIDE
FIBER STRAIN RELIEF
SUGGESTED LAYOUT OF
CABLES FOR FIBER STRAIN
RELIEF (SECURE CABLES W/
CABLE TIES AS REQUIRED)
1
MANUFACTURER:COMMSCOPE
MODEL:FFVV-65C-R3-V1
WEIGHT:124.56 LBS
DIMENSIONS:95.94" x 25.2" x 9.25"
FREQUENCY:B5, B66, B71
95.94"25.2"9.25"9.25"25.2"
FRONT SIDE
TOP
ISO
RET 1 R1 L
617-894 MHz 2
-45°
RET 1 R1 L
617-894 MHz 1
+45°
RET 2 Y1 L
1695-2690 MHz 5
+45°
RET 2 Y1 L
1695-2690 MHz 6
-45°
RET 3 R2 R
617-894 MHz 3
+45°
RET 1 R2 R
617-894 MHz 4
-45°
RET 3 Y2 R
1695-2690 MHz 8
-45°
RET 3 Y2 R
1695-2690 MHz 7
+45°
AISG IN AISG OUT
BOTTOM
SKU# 34094 - FFVV-65C-R3-V1
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
SITEPRO1 - R5 UNIVERSAL
ANTENNA MOUNT (PART #
R5-216) OR APPROVED EQUAL31"18"12.4"
LEFT FRONT
MANUFACTURER:KOHLER
MODEL:KCS ATS
WEIGHT:68 LBS
DIMENSIONS:31"x18"x12.4"31"STRUCTURAL WELDING DETAIL SITE PREPARATION
AND POST APPLICATION NOTES:
1.PRIOR TO PRE-CONSTRUCTION MEETING, GC OR
CM SHALL COORDINATE W/ WATER DISTRICT
REPRESENTATIVE REGARDING SPECIFIC
SPECIFICATIONS OF EXISTING EPOXY PAINT MFR
AND MODEL NUMBER AS A PART OF THE BOM.
2.PRIOR TO STRUCTURAL WELDING, REVIEW
STRUCTURAL NOTES (5/S-3.1)
3.AFTER APPLICATION OF STRUCTURAL WELDING,
GC SHALL THOROUGHLY CLEAN AREA OF WELD
CONNECTION(S) AND PLATES OF STRUCTURAL
WELDING INCLUDING ADJACENT SURFACES.
4.GC SHALL REVIEW AND EXECUTE EPOXY PAINT
MFR AND MODEL NUMBER APPLICATION OVER
AREAS OF CONNECTION EPOXY APPLICATION.
5.REVIEW STRUCTURAL SPECIAL INSPECTIONS.
EXISTING PLATFORM AND
GUARDRAIL BEYOND
EXISTING WATER
TANK
SEE STRUCTURAL WELDING
DETAIL SITE PREPARATION AND
POST APPLICATION NOTES
STD PIPE KICKER BRACES
PER STRUCTURAL
PLATE PER STRUCTURAL
SITEPRO1 UNIVERSAL PIPE
MOUNT (MODEL NO, R5-216)
4" STD PIPE MAST PER
STRUCTURAL
PROVIDE ADDITIONAL 3" STD PIPE
CROSS-ARM. ATTACH TO 41/2" O.D. VERT
PIPE W/ SITEPRO1 SP216 CROSSOVER
PLATE.
SITEPRO1 SCX43-K
CROSSOVER PLATE, TYP AT
ANTENNA PIPE MOUNTS
6
A-5.4
EQUIPMENT DETAILS
A-5.422"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.6R5-UNIVERSAL ANTENNA MOUNT DETAIL
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
NOT USED 322"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2KCS ATS DETAIL
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.4MOISTURE PROTECTION DETAIL
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.4GENERAL NOTICE SIGN
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1NOCC SIGN
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.6RF NOTICE / WARNING SIGN
SIGNAGE DETAILS
A-6.0
NOTES:
1.8” X 12” ALUMINUM
2.POSTED AT EACH ENTRANCE (GATE, DOOR,
HATCHWAY, ETC.)
3.BUILDING OWNER MAY HAVE RESTRICTIONS
ON WHERE CAN BE POSTED
4.SEE SIGN PLACEMENT TABLE FOR
ADDITIONAL INFORMATION.
NOTES:
1.8” X 12” ALUMINUM
2.POSTED AT BASE OF TOWER
3.SEE SIGN PLACEMENT TABLE FOR
ADDITIONAL INFORMATION.
Ref FCC 47CFR 1.1307(o)
Beyond This Point you are
entering an area where RF
Emissions may exceed the FCC
General Population Exposure
Limits
Follow all posted signs and site guidelines
for working in an RF environment
On this tower:
Radio frequency fields near some
antennas may exceed FCC rules
for human exposure.
Personnel climbing this tower should be
trained for working in radio frequency
environments and use a personal RF
monitor if working near active antennas.
Ref FCC 47CFR 1.1307(o)
BLUEYELLOW
NOTICE
GENERAL INFORMATION FOR WORKING IN
THE AREA OF ANTENNAS
·ALL PERSONNEL ENTERING THIS SITE MUST BE
AUTHORIZED.
·OBEY ALL POSTED SIGNS.
·ASSUME ALL ANTENNAS ARE ACTIVE.
·MAINTAIN MINIMUM DISTANCE OF 3 FEET CLEARANCE
FROM ANTENNAS.
CALL 1-888-222-5548 FOR INFORMATION OR ASSISTANCE
Beyond this point you are entering an
area where RF Emissions may exceed
the FCC General Population Exposure
Limits
Follow all posted signs and site guidelines for
working in an RF environment
Ref: FCC47CFR 1.137(b)
NOTICE
IN CASE OF
EMERGENCY
CALL
N.O.C.C.
1-800-662-4662
1. SIGNS & PLACEMENT:
A. LOW LEVEL (BLUE) WARNING SIGNS - PLACE AT SITE
ENTRY/ACCESS POINTS ONLY:
ROOF TOPS: PLACE SIGNS ON THE INSIDE OF ROOF
HATCH; PLACE ON ACCESS DOOR UNLESS DOOR IS USED
BY GENERAL PUBLIC OR BUILDING TENANTS REGULARLY
FOR ACCESS - IN THESE CASES CONSULT CONSTRUCTION
MANAGER OR QC SUPERVISOR
WATER TANKS: PLACE SIGNS ON COMPOUND GATE
B. HIGH LEVEL (RED) CAUTION SIGNS - PLACE AT ALL
ANTENNA SECTORS WHERE ACCESS BY THE GENERAL
PUBLIC TO THE ANTENNAS IS POSSIBLE:
ALL SIGNS WILL BE SECURED WITH EITHER STAINLESS
STEEL ZIP TIES OR STAINLESS TECH SCREWS
2. CC PARTICIPATION IN SIGN LOCATION:
A. CM WILL MEET WITH ALL CC'S TO OUTLINE CRITERIA FOR
SIGN PLACEMENT; EMPHASIS WILL BE ON 'GRAY AREA'
SITES, WHERE SIGN PLACEMENT IS PARTICULARLY
CHALLENGING - WE WILL GIVE CC'S AS MUCH GUIDANCE
ON SPECIFIC SITUATIONS AS WE CAN FORESEE, BUT CC'S
WILL BE ENCOURAGED TO PARTNER CM OR QC IN
DECIDING PLACEMENT OF DIFFICULT SITES. A JOINT SITE
VISIT MAY BE REQUIRED TO FULFILL REQUIREMENTS
B. CC WILL CALL OUT SIGN LOCATION(S) AT THE A&E WALK
FOR EACH SITE AS THOSE OCCUR ON SITES WITH EXISTING
A&E BUT NOT YET CONSTRUCTED, CC WILL BE ASKED TO
PROVIDE (WITHIN A REASONABLE TIME FRAME TBD) A
DETAIL FOR SIGN PLACEMENT THAT WILL BE SLIP-SHEETED
INTO EXISTING SETS
1-888-662-4662
Site No.: ________________
IN CASE OF AN EMERGENCY CALL
Site Name: ____________________
SE04227A
HERITAGE WOODS PARK-HGHLN
WTR DT - SE52XC241
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2SIGN PLACEMENT NOTES
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.5THERMAL RUNWAY PROCEDURE
THERMAL RUNAWAY PROCEDURE POSTING
ATTACHMENT TO A THERMAL RUNAWAY PROCEDURE
HANDLING OVERHEATING BATTERIES OR THERMAL RUNAWAY
(A COPY OF THIS PAGE SHALL BE A LAMINATED OR PLACED IN A PLASTIC SHEET PROTECTOR AND POSTED
IN ALL BATTERY AREAS.)
IF YOU ENCOUNTER BATTERIES TOO HOT TO TOUCH, THAT MAKE HISSING OR WHISTLING NOISES FROM
THEIR VENTS:
·THERE IS A FIRE OR SMOKE
·IF THE FIRE ALARMS ARE SOUNDING
·IF THERE IS A STRONG ROTTEN EGG (HYDROGEN SULFIDE) ODOR
IMPORTANT: TAKE NO ACTION THAT COULD PRODUCE A SPARK AND IGNITE AIRBORNE HYDROGEN.
IF YOU ENCOUNTER BATTERIES TOO HOT TO TOUCH BUT THERE IS NO SMOKE AND IT IS SAFE TO REMAIN IN
THE FACILITY:
·CALL FOR HELP
·INCREASE VENTILATION IN BATTERY AREA
·REDUCE CHARGE CURRENT EITHER BY TURNING OFF ENOUGH RECTIFIERS SO THAT THE LOAD
BARELY IS COVERED OR BY LOWERING THE FLOAT VOLTAGE
·INCREASE COOLING IN THE BATTERY AREA IF POSSIBLE
·IF THERE IS A SPILL OR OTHER HAZARDOUS SITUATION CALL THE ENVIRONMENTAL HOTLINE AT
1-800-488-7900
DO NOT OVERREACT TO BATTERY EMERGENCIES. BURNING BATTERIES RELEASE POTENTIALLY LETHAL
CONCENTRATIONS OF TOXIC GASES OR OTHER CHEMICALS AND SHOULD BE HANDLED BY TRAINED FIRST
RESPONDERS (FIRE DEPARTMENT) WITH APPROPRIATE PROTECTIVE CLOTHING AND SELF-CONTAINED
BREATHING APPARATUS (SCBA).
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PROPOSED GENERATOR ANCHORAGE NOTES & SPECIAL INSPECTIONS (APPLICABLE FOR ANCHORAGE TO PROPOSED SLABS)
1.GENERAL
1.1.ALL CONSTRUCTION SHALL CONFORM TO THE 2018 INTERNATIONAL
BUILDING CODE. REFERENCE TO OTHER STANDARDS OR CODES
SHALL MEAN THE LATEST STANDARD OR CODE ADOPTED &
PUBLISHED.
1.2.DRAWINGS SHOW TYPICAL & CERTAIN SPECIFIC CONDITIONS ONLY.
FOR DETAILS NOT SPECIFICALLY SHOWN, PROVIDE DETAILS SIMILAR
TO THOSE SHOWN.
1.3.EXISTING STRUCTURES & UNDERGROUND UTILITIES/STRUCTURES
ARE ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL EXISTING
CONDITIONS, DIMENSIONS & ELEVATIONS BEFORE STARTING WORK.
NOTIFY STRUCTURAL ENGINEER IN WRITING OF ANY INTERFERENCE
AND/OR DISCREPANCIES THAT MIGHT EXIST.
1.4.THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION BRACING,
SHORING TEMPORARY SUPPORTS, ETC., IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR.
1.5.COORDINATE STRUCTURAL CONTRACT DOCUMENTS WITH
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING & CIVIL.
NOTIFY STRUCTURAL ENGINEER OF ANY CONFLICT AND/OR OMISSION.
1.6.COORDINATE & VERIFY FLOOR, ROOF AND WALL OPENING SIZES &
LOCATIONS WITH ARCHITECTURAL, MECHANICAL, PLUMBING &
ELECTRICAL DRAWINGS. FOR ADDITIONAL OPENINGS NOT SHOWN ON
THE STRUCTURAL DRAWINGS, SEE ARCHITECTURAL & MECHANICAL
DRAWINGS.
1.7.FOR DIMENSIONS NOT SHOWN, SEE ARCHITECTURAL DRAWINGS.
1.8.REVIEW OF SUBMITTALS AND/OR SHOP DRAWINGS BY THE
STRUCTURAL ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF
THE RESPONSIBILITY TO REVIEW & CHECK SHOP DRAWINGS BEFORE
SUBMITTAL TO THE STRUCTURAL ENGINEER. THE CONTRACTOR
REMAINS SOLELY RESPONSIBLE FOR ERRORS & OMISSIONS
ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY
PERTAIN TO MEMBER SIZES, DETAILS, & DIMENSIONS SPECIFIED IN
THE CONTRACT DOCUMENTS. CONTRACTOR IS ALSO RESPONSIBLE
FOR MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES OF CONSTRUCTION.
1.9.STRUCTURAL DESIGN DRAWINGS SHALL NOT BE REPRODUCED AS
SHOP DRAWINGS. CONTRACTOR & THEIR SUBCONTRACTORS SHALL
PREPARE ORIGINAL SHOP DRAWINGS.
1.10.CONTRACTOR SHALL REVIEW & STAMP ALL SHOP DRAWINGS BEFORE
SUBMITTAL FOR REVIEW. PROPOSED FABRICATION CHANGES FROM
DESIGN DRAWINGS SHALL BE NOTED IN SHOP DRAWINGS. ANY
DISCREPANCIES BETWEEN ARCHITECTURAL & STRUCTURAL
DRAWINGS SHALL BE NOTED TO BE VERIFIED ON SHOP DRAWINGS.
1.11.COMPLETE SHOP DRAWINGS FOR CONSTRUCTION OF ALL
APPLICABLE SPECIALTY ITEMS INCLUDING CURTAIN WALL GLAZING
SYSTEMS, LIGHT GAUGE STEEL FRAMING, ORNAMENTAL GUARDRAILS,
SKYLIGHTS, METAL GRATING & STAIRS SHALL BE SEALED & SIGNED BY
A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF
WASHINGTON & SHALL BE AVAILABLE AT THE JOB SITE DURING THE
TIMES OF INSPECTION.
1.12.FOR SITE-SPECIFIC LOAD PARAMETERS, SEE THE GENERATOR
ANCHORAGE REPORT.
2.FOUNDATIONS & SLAB ON GRADE
2.1.THE DESIGN OF FOUNDATIONS, RETAINING WALLS & SLAB-ON-GRADE
IS BASED ON THE CRITERIA ASSUMED BY THE STRUCTURAL
ENGINEER. ALL DESIGN ASSUMPTIONS SHALL BE VERIFIED BY A
GEOTECHNICAL ENGINEER REGISTERED IN THE STATE OF
WASHINGTON & DESIGNATED BY THE OWNER PRIOR TO START OF
THE WORK.
2.2.TOP OF FOOTING ELEVATIONS SHOWN ON STRUCTURAL DRAWINGS
ARE FOR ESTIMATING ONLY. FINAL BEARING ELEVATIONS FOR
FOOTINGS SHALL BE DETERMINED IN THE FIELD BY THE
GEOTECHNICAL ENGINEER TO SATISFY ASSUMED DESIGN BEARING
VALUES.
2.3.DRILL SMALL TEST HOLE IN SUBGRADE UNDER FOOTING BEARINGS
TO CONFIRM BEARING CONDITIONS WHERE REQUIRED BY THE
GEOTECHNICAL ENGINEER.
2.4.GEOTECHNICAL ENGINEER SHALL VERIFY CONDITION AND/OR
ADEQUACY OF ALL SUBGRADES, FILLS & BACKFILLS BEFORE
PLACEMENT OF FOUNDATIONS, FOOTINGS, SLABS, WALLS, FILLS,
BACKFILLS, ETC.
2.5.SIDES OF FOUNDATIONS SHALL BE FORMED UNLESS CONDITIONS
PERMIT EARTH FORMING. FOUNDATIONS POURED AGAINST THE
EARTH REQUIRE THE FOLLOWING PRECAUTIONS: SLOPE SIDES OF
EXCAVATIONS AS APPROVED BY GEOTECHNICAL ENGINEER & CLEAN
UP SLOUGH BEFORE & DURING CONCRETE PLACEMENT.
2.6.WHERE FOOTING STEPS ARE NECESSARY, THEY SHALL BE NO
STEEPER THAN ONE VERTICAL TO TWO HORIZONTAL.
2.7.COMPACT ALL FILL USED UNDER SLAB TO 95% OF STANDARD
PROCTOR DENSITY AT OPTIMUM MOISTURE CONTENT.
2.8.ESTABLISH BENCH MARKS ON SURROUNDING STRUCTURES &
PAVEMENTS PRIOR TO EXCAVATION, MONITOR VERTICAL &
HORIZONTAL REGULARLY DURING EXCAVATION & CONSTRUCTION &
SUBMIT WRITTEN REPORTS TO ARCHITECT & STRUCTURAL ENGINEER
FOR REVIEW.
2.9.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY IN
CONNECTION WITH EARTH SLOPES CAUSED BY TRENCHING,
EXCAVATION AND/OR FILL DURING CONSTRUCTION.
2.10.BOTTOM OF ALL FOUNDATIONS SHALL EXTEND A MINIMUM OF 12
INCHES BELOW THE TOP OF FINISH GRADE.
3.REINFORCED CONCRETE
3.1.ALL CONCRETE WORK SHALL CONFORM TO ACI 301, SPECIFICATIONS
FOR STRUCTURAL CONCRETE FOR BUILDINGS. DESIGN IS BASED ON
ACI 318-14, BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE
3.2.UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL BE NORMAL
WEIGHT & SHALL HAVE MINIMUM 28 DAY STRENGTHS AS FOLLOWS:
3.3.THE PROPOSED MATERIALS & MIX DESIGN SHALL BE FULLY
DOCUMENTED & REVIEWED BY THE OWNER'S TESTING LABORATORY.
RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH
IS THE CONTRACTOR'S.
3.4.USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN
CONCRETE IS NOT PERMITTED.
3.5.HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED ONLY WHERE
INDICATED. THE LOCATIONS OF VERTICAL CONSTRUCTION JOINTS
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
CONSTRUCTION JOINTS SHALL BE THOROUGHLY ROUGHENED BY
MECHANICAL MEANS & CLEANED.
3.6.UNLESS NOTED OTHERWISE, CHAMFER OR ROUND ALL EXPOSED
CORNERS MINIMUM 3/4". SEE ARCHITECTURAL DRAWINGS FOR
CHAMFER OR REVEAL REQUIREMENTS FOR ARCHITECTURAL
CONCRETE.
3.7.DETAIL CONCRETE REINFORCEMENT & ACCESSORIES IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 315 & ACI DETAILING
MANUAL (LATEST EDITION). SUBMIT SHOP DRAWINGS FOR REVIEW
SHOWING ALL FABRICATION DIMENSIONS & LOCATIONS FOR PLACING
REINFORCING STEEL & ACCESSORIES. DO NOT BEGIN FABRICATION
UNTIL SHOP DRAWINGS ARE COMPLETED & REVIEWED.
3.8.DETAIL ALL CONCRETE WALLS & BEAMS ON THE SHOP DRAWINGS IN
ELEVATION UNLESS SPECIFICALLY APPROVED OTHERWISE.
3.9.REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60
UNLESS NOTED OTHERWISE.
3.10.WELDED WIRE FABRIC (MESH) SHALL CONFORM TO ASTM A185.
3.11.TIE ALL REINFORCING STEEL & EMBEDMENTS SECURELY IN PLACE
PRIOR TO PLACING CONCRETE. PROVIDE SUFFICIENT SUPPORTS TO
MAINTAIN THE POSITION OF REINFORCEMENT WITHIN SPECIFIED
TOLERANCES DURING ALL CONSTRUCTION ACTIVITIES.
3.12.PROVIDE CONTINUOUS REINFORCEMENT WHEREVER POSSIBLE;
SPLICE ONLY AS SHOWN OR APPROVED; STAGGER SPLICES WHERE
POSSIBLE; USE FULL TENSION SPLICE UNLESS NOTED OTHERWISE.
3.13.REINFORCING STEEL SHALL HAVE THE FOLLOWING CONCRETE
COVER UNLESS NOTED OTHERWISE:
CONCRETE AGAINST EARTH (NOT FORMED)3"
FORMED CONCRETE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS 2"
#5 BARS & SMALLER 1-1/2"
CONCRETE NOT EXPOSED TO EARTH OR WEATHER
SLABS & WALLS 1"
BEAMS (STIRRUPS) & COLUMNS (TIES)1-1/2"
3.14.DO NOT WELD OR TACK WELD REINFORCING STEEL UNLESS
APPROVED OR DIRECTED BY THE STRUCTURAL ENGINEER.
3.15.STEEL REINFORCEMENT TO BE WELDED SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A706 & THAT WELDING SHALL BE IN
ACCORDANCE WITH AWS D1.4, STRUCTURAL WELDING CODE -
REINFORCING STEEL BY AMERICAN WELDING SOCIETY FOR
COMPLIANCE WITH ACI 318-14 SECTION 3.2.5.
3.16.SEE CIVIL & ARCHITECTURAL DRAWINGS FOR EXTERIOR SLAB WORK &
JOINTING.
3.17.INCLUDE AIR ENTRAINING ADMIXTURE IN ALL CONCRETE THAT WILL
BE EXPOSED TO WEATHER EXCEPT IN FOOTINGS.
3.18.INCLUDE WATER REDUCING ADMIXTURE IN ALL CONCRETE MIXES.
3.19.THE PROPOSED MATERIALS & MIX DESIGN SHALL BE FULLY
DOCUMENTED & REVIEWED BY THE OWNER'S TESTING LABORATORY.
RESPONSIBILITY FOR OBTAINING THE REQUIRED DESIGN STRENGTH
IS THE CONTRACTOR'S. RESULTS OF COMPRESSIVE STRENGTH TESTS
SHALL BE AVAILABLE ON SITE FOR INSPECTOR'S REVIEW.
3.20.BARS, OTHER THAN GRADE 40, SHALL BE MILL MARKED SO THAT TYPE,
GRADE & YIELD STRENGTH ARE VISIBLY IDENTIFIABLE.
3.21.PROVIDE CORNER BARS AS PER TYPICAL DETAIL AT CORNERS &
INTERSECTIONS OF ALL GRADE BEAMS & WALLS.
3.22.PROVIDE #3 @ 12" DOWELS FROM ALL ADJACENT CONCRETE GRADE
BEAMS & WALLS TO INTERIOR SLABS-ON-GROUND, U.N.O.
3.23.ALL REINFORCING LAP SPLICES, UNLESS OTHERWISE SHOWN, SHALL
SATISFY THE FOLLOWING SCHEDULE:
ALL BAR DEVELOPMENT LENGTHS, UNLESS OTHERWISE SHOWN,
SHALL SATISFY THE FOLLOWING SCHEDULE:
* TOP BAR SHALL BE DEFINED AS ANY HORIZONTAL BARS
PLACED SUCH THAT MORE THAN 12" OF FRESH CONCRETE IS
CAST IN THE MEMBER BELOW THE BAR, IN ANY SINGLE
CONCRETE PLACEMENT. HORIZONTAL WALL BARS ARE
CONSIDERED TOP BARS.
4.POST-INSTALLED REBAR & ANCHORS
4.1.SPECIFIC PRODUCT, DIAMETER, AND EMBEDMENT SHALL BE SHOWN
IN THE DETAILS. INSTALL PRODUCTS IN ACCORDANCE WITH
MANUFACTURER' PRINTED INSTALLATION INSTRUCTIONS (MPII).
CONTRACTOR SHALL CONTACT MANUFACTURER'S REPRESENTATIVE
FOR PRODUCT INSTALLATION TRAINING AND SHALL SUBMIT LETTER
TO THE ENGINEER-OF-RECORD (EOR) INDICATING TRAINING HAS
TAKEN PLACE. REFER TO THE PROJECT BUILDING CODE AND/OR
EVALUATION REPORT FOR SPECIAL INSPECTIONS AND PROOF LOAD
REQUIREMENTS. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER
THAN THOSE LISTSED BELOW MAY BE SUBMITTED BY THE
CONTRACTOR TO THE EOR FOR REVIEW. SUBSTITUTIONS WILL ONLY
BE CONSIDERED FOR PRODUCTS HAVING A RESEARCH REPORT
RECOGNIZING THE PRODUCT FOR THE APPROPRIATE APPLICATION
UNDER THE PROJECT BUILDING CODE. SUBSTITUTION REQUEST
SHALL INCLUDE CALCULATIONS THAT DEMONSTRATE THE
SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE EQUIVALENT
PERFORMANCE VALUES OF THE DESIGN BASIS PRODUCT.
4.2.FOR ANCHORING INTO CONCRETE:
4.2.a.MECHANICAL ANCHORS SHALL HAVE BEEN TESTED IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193 FOR CRACKED
CONCRETE AND SEISMIC APPLICATIONS.
4.2.b.ADHESIVE FOR REBAR AND ANCHORS SHALL HAVE BEEN
TESTED IN ACCORDANCE WITH ACI355.4 AND ICC-ES AC308 FOR
CRACKED CONCRETE AND SEISMIC APPLICATIONS. DESIGN
ADHESIVE BOND STRENGTH HAS BEEN BASED ON ACI 355.4
TEMPERATURE CATEGORY B WITH INSTALLATIONS INTO DRY
HOLES DRILLED USING A CARBIDE DRILL BIT INTO CRACKED
CONCRETE THAT HAS CURED FOR AT LEAST 21 DAYS. ADHESIVE
ANCHORS REQUIRING CERTIFIED INSTALLATIONS SHALL BE
INSTALLED BY A CERTIFIED ADHESIVE ANCHOR INSTALLER PER
ACI 318-14 17.8.2.2. INSTALLATIONS REQUIRING CERTIFIED
INSTALLERS SHALL BE INSPECTED PER ACI 318-14 17.8.2.4.
5.SPECIAL INSPECTIONS
5.1.STRUCTURAL TESTS AND INSPECTIONS SHALL COMPLY WITH THE
REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
5.1.a.THE INSPECTOR SHALL BE HIRED AND PAID FOR BY THE OWNER.
5.1.b.THE INSPECTOR SHALL BE RESPONSIBLE FOR COMPLIANCE
WITH THE APPROVED STRUCTURAL PLANS AND SHALL SUBMIT
PROGRESS REPORTS AND INSPECTION REPORTS TO THE
BUILDING OFFICIAL AND TO THE STRUCTURAL ENGINEER OF
RECORD.
5.2.SATISFY MINIMUM INSPECTION AND QUALITY CONTROL
REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
CONCRETE DURABILITY REQUIREMENTS PER ACI-318
FOUNDATIONS
28-DAY COMPRESSIVE
STRENGTH (f'c)
FREEZING/THAWING CLASS
SULFATE CLASS
PERMEABILITY CLASS
CORROSION CLASS
MAX AGGREGATE(IN)
MAX W/CM RATIO
TARGET AIR CONTENT(%)
6.0
PROJECT SCHEDULE OF SPECIAL INSPECTIONS
MATERIAL/ACTIVITY SERVICE
APPLICABLE TO THIS PROJECT
Y/N EXTENT AGENT DATE COMPLETED
1705.3 CONCRETE CONSTRUCTION
1. INSPECTION OF REINFORCING STEEL INSTALLATION (SEE 1705.2.2 FOR WELDING)SHOP (3) AND FIELD
INSPECTION Y PERIODIC
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE ALLOWABLE LOADS HAVE
BEEN INCREASED PER SECTION 1908.5 OR WHERE STRENGTH DESIGN IS USED
SHOP (3) AND FIELD
INSPECTION Y PERIODIC
4. INSPECTION OF ANCHORS AND REINFORCING STEEL POST-INSTALLED IN
HARDENED CONCRETE PER RESEARCH REPORTS INCLUDING VERIFICATION OF
ANCHOR TYPE, ANCHOR DIMENSIONS, HOLE DIMENSIONS, HOLE CLEANING
PROCEDURES, ANCHOR SPACING, EDGE DISTANCE, CONCRETE MINIMUM
THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING TORQUE
FIELD INSPECTION Y
PERIODIC OR AS REQUIRED
BY THE RESEARCH REPORT
ISSUED BY AN APPROVED
SOURCE
5. VERIFY USE OF APPROVED DESIGN MIX SHOP (3) AND FIELD
INSPECTION Y PERIODIC
6. FRESH CONCRETE SAMPLING, PERFORM SLUMP AND AIR CONTENT TESTS AND
DETERMINE TEMPERATURE OF CONCRETE
SHOP (3) AND FIELD
INSPECTION Y CONTINUOUS
7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES
SHOP (3) AND FIELD
INSPECTION Y CONTINUOUS
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND
TECHNIQUES
SHOP (3) AND FIELD
INSPECTION Y PERIODIC
1705.12.1 STRUCTURAL STEEL SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
1. INSPECTION OF STRUCTURAL STEEL IN ACCORDANCE WITH AISC 341 SHOP (3) AND FIELD
INSPECTION Y IN ACCORDANCE WITH AISC
341
1705 POST-INSTALLED ANCHORS
1. PREPARE A REPORT INCLUDING THE FOLLOWING DETAILS:
A. ANCHOR DESCRIPTION, INCLUDING THE ANCHOR PRODUCT NAME, BOLT
DIAMETER, AND ANCHOR LENGTH FIELD INSPECTION Y CONTINUOUS
B. HOLE DESCRIPTION INCLUDING VERIFICATION OF DRILL BIT COMPLIANCE
WITH ANSI B212.15-1994. RECORD INSTALLATION DESCRIPTION, INCLUDING
VERIFICATION OF MASONRY/CONCRETE COMPRESSIVE STRENGTH, AND
ANCHOR INSTALLATION AND LOCATION (SPACING AND EDGE DISTANCE) IN
ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION
INSTRUCTIONS
FIELD INSPECTION Y CONTINUOUS
CONCRETE REINFORCEMENT LAP SPLICE LENGTH (in) GRADE 60
BAR
SIZE
#3 #4 #5 #6 #7 #8 #9 #10 #11
TOP
BAR *23 31 38 46 67 76 86 96 107
OTHER 18 24 30 35 51 59 66 74 82
CONCRETE REINFORCEMENT DEVELOPMENT LENGTH (in) GRADE 60
BAR
SIZE
#3 #4 #5 #6 #7 #8 #9 #10 #11
TOP
BAR *18 24 30 35 51 59 66 74 82
OTHER 14 18 23 27 40 45 51 57 64
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1
STRUCTURAL NOTES &
SPECIAL INSPECTIONS
S-1.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 6-29-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
S u r ve yin g
Eng ineer ing
Pla nn in g
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
REENIGNELANOISSEFORP
NOTGNIHSAWFOETATS
G
A
R
N S
RET T J O H
KELT
N
O
57020DERETSIGER
6/29/21
CONTRACTOR NOTE:
1.SEE ARCHITECTURAL DRAWINGS FOR
PLACEMENT.
2.SEE GEOTECHNICAL REPORT FOR
OVER-EXCAVATION AND FILL
REQUIREMENTS
CONCRETE PAD REQUIREMENTS:
1.4,500 PSI MIN CONCRETE STRENGTH (f'c)
2.60,000 PSI MIN REBAR STRENGTH (fy)
3.1,000 PSF MIN ALLOWABLE SOIL BEARING
4.0.25 MIN SOIL/CONCRETE FRICTION COEFFICIENT
5.150 PCF MIN SOIL PASSIVE RESISTANCE
GENERATOR, SEE ARCH, w/(4)
5/8"Ø SS SIMPSON STRONG-TIE
STRONG BOLT 2 EXPANSION
ANCHORS w/3-5/8" EMBEDMENT
GENERATOR
(MAX 3090#)
(MIN 2000#)
5'-0" (x 9'-0" LONG)
3" CLR3" CLR
\A1;3" CLR
#5 @ 14" o.c. T&B
(5)#5 T&B, EVENLY SPACED
3'-2 1/8" MIN 0'-6 1/2" MIN EDGE DISTANCE
PROPOSED
CONCRETE PAD7'-4 3/4" MAX3" CLR2" CLR1'-10"4"1'-6"FROSTSTRUCTURAL DETAILS
S-2.0NOT USED 6
NOT USED 1
NOT USED 4
NOT USED 3NOT USED 2
5GENERATOR ANCHORAGE DETAIL
22"x34" SCALE: 3/4" = 1'-0"11"x17" SCALE: 3/8" = 1'-0"
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 6-29-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
S u r ve yin g
Eng ineer ing
Pla nn in g
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
REENIGNELANOISSEFORP
NOTGNIHSAWFOETATS
G
A
R
N S
RET T J O H
KELT
N
O
57020DERETSIGER
6/29/21
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1GENERATOR SPECIFICATIONS
1.PLACE AT DOOR OR TANK.
2.SIGNS MUST BE OF DURABLE MATERIAL WITH RED LETTERING (OR
OTHERWISE SHOWN IN GRAPHICS) ON A WHITE BACKGROUND.
3.LETTERS SHALL NOT BE LESS THAN 3 INCHES (76.2 MM) IN HEIGHT AND 1/2
INCH (12.7 MM) IN STROKE.
4.SIGNS SHALL NOT BE OBSCURED OR REMOVED AND SHALL BE IN ENGLISH
AS PRIMARY LANGUAGE
5.COMBUSTIBLE SIGN MAY ALSO BE WHITE LETTERS ON RED BACKGROUND.
HAZARD RANGE:
NINE O'CLOCK:HEALTH
TWELVE O'CLOCK:FLAMMABILITY
THREE O'CLOCK:INSTABILITY
SIX O'CLOCK:SPECIAL
REFERENCES:NFPA 704
WFC 7901.9
IFC 2703.5
NOTES
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2TANK SIGNAGE
229 GALLON
DIESEL
PRODUCT IDENTIFICATION
00
2
COMBUSTIBLE
FLAMMABLE
NO SMOKING
DIESEL GENERATOR
SPECIFICATIONS
M-1.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1GENERATOR SPECIFICATIONS
DIESEL GENERATOR
SPECIFICATIONS
M-2.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1GENERATOR TANK SPECIFICATIONS
DIESEL GENERATOR
SPECIFICATIONS
M-3.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PROPOSED
AHLOA UNIT
PROPOSED
AHFIG UNIT
PROPOSED HCS
2.0 EQUIPMENT
JUNCTION BOX
PROPOSED HCS
2.0 EQUIPMENT
JUNCTION BOX
PROPOSED (4) ABIL LOCATED
WITHIN AMIA RACK
PROPOSED (2) ASIK LOCATED
WITHIN AMIA RACK
PROPOSED (3) ABIA
LOCATED WITHIN AMIA RACK
PROPOSED (2) ASIB
LOCATED WITHIN AMIA RACK
PROPOSED
FSMF MODULE
PROPOSED (2) AMIA RACKS
PROPOSED (3) ABIC LOCATED
WITHIN AMIA RACK
AEHC
FFVV-65C-R3-V11RF PLUMBING DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
RF PLUMBING DIAGRAM
RF-1.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
IXR-e
FTLX8573D3BTL
AEHC
OPT1
OPT2
OPT1
OPT2
FTLX8573D3BTL
FOTAFOTA
LTE TDD-eNB2 NR TDD-gNB
AOSD AOSD
ABIL
ASIK
ABIC
ASIB
AOSD AOSD
AEHC FIBER CONNECTIONS DIA.
1ONE SECTOR SFP DETAIL
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
SFP DETAIL
RF-1.1
NOKIA ITEM CODE/SECTOR PRODUCT NAME
474932A AOSD QSFP28 SM 10Km LC
473471A FOTA Optical SFP+ 10GBase-SR 850nm MM
FTLX8573D3BTL 10Gb/s 850nm Multimode SFP+ Datacom Transceiver
x 12
x 0
x 2
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
2'-0"
4"3'-0"4'-0"JURISDICTION MAY REQUIRE DIRECTIONAL BORING OF
TRENCH FOR CONDUITS - CONSULT WITH JURISDICTION.
3" MIN ELECTRICAL CONDUIT
SAND FILL
COMPACTED FILL
PER UTILITY CO REQ
UNEXCAVATED AREA
TRENCHEXCAVATION/MAGNETIC
WARNING TAPE
MATCH EXISTING
SURFACE
M
100A,
1P
PROVIDE 200A, 120/240V, 1PH,
3W METER SOCKET AND
CIRCUIT BREAKER
COMBINATION AND ARRANGE
WITH SUPPLY AUTHORITY TO
PROVIDE 200A SERVICE METER
TO POINT OF UTILITY
CONNECTION. SIZE
CONDUCTORS PER NEC.
3" C. W/ PULL WIRE
NEMA 3R ENCLOSURE
(1) #4 CU, 3/4" C.
TO GROUNDING
SYSTEM
PANEL
A
WP
200A GENERATOR
RECEPTACLE
(3) #3/0 & (1) #6
GRD, 2" C.
POWER
CABINET
(3) #3/0 & (1) #6
GRD, 2" C.
TVSS
AC FAIL
RELAY
ELECTRICAL SITE PLAN
E-1.01
3
ELECTRICAL SITE PLAN
ELEC/TELCO TRENCH
22"x34" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
2ONE-LINE DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.
22"x34" SCALE: 3/4" = 1'-0"11"x17" SCALE: 3/8" =1 '-0"
NOTE:
1.CONTRACTOR SHALL CALL FOR LOCATES PRIOR TO TRENCHING.
2.THE LOCATION OF UTILITY CONDUIT ROUTING SHOWN ARE
APPROXIMATE.
3.COORDINATE EXACT CONDUIT ROUTING AND STUB UP LOCATIONS
WITH UTILITIES AND CONSTRUCTION MANAGER PRIOR TO ROUGH-IN.
GENERATOR NOTE:
·GENERATOR START CIRCUITS FROM GENERATOR TO ATS
·GENERATOR CONTROL ALARM WIRES (4 PAIR, #18 AWG INDIVIDUALLY
SHIELDED PAIRS) FROM GENERATOR TO SHELTER
·STANDBY POWER FEED FOR SHELTER (2) 3/0-AWG + (1) #4 GND
·GENERATOR ANCILLARY CIRCUITS (BATTERY CHARGER/BLOCK
HEATER) (3) #12 AWG TO DEDICATED 20 AMP SP BREAKER AT SHELTER
·22 AWG CAT 5 (FUEL TANK ALARMS)
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
PROPOSED T-MOBILE (2) 4"Ø SCHD 40
PVC CONDUITS FOR POWER & ALARM
CONTROL FROM GENERATOR TO ATS.
SEE GENERATOR NOTE.
PROPOSED T-MOBILE 40kW DIESEL
GENERATOR W/ TANK VENT ON CONCRETE
PAD (1 TOTAL).
PROPOSED T-MOBILE ATS CABINET
MOUNTED TO EXISTING H-FRAME.
EXISTING SPRINT UTILITY H-FRAME WITH
POWER AND TELCO CABINET (TO REMAIN).
EXISTING 200A, 120/240, 1PH ELECTRICAL SERVICE
ORIGINATING FROM AN EXISTING PSE POWER UTILITY
TRANSFORMER W/ SERVICE CONTINUING TO THE
CURRENT METER AND DISCONNECT (TO REMAIN AND
PROVIDE CONTINUED SERVICE AND CONFIRMED VIA UCR)
EXISTING FIBER SOURCE ORIGINATING FROM AN
EXISTING ON SITE FIBER SERVICE CONTINUING TO
EXISTING FIBER PANEL (TO REMAIN AND PROVIDE
CONTINUED SERVICE AND CONFIRMED VIA UCR)
PROPOSED 2" RIGID CONDUIT
(4) TOTAL, FROM HPL3 CABINET,
TO (E) PANEL, (E) TELCO
CABINET AND JUNCTION BOXES
NOTE:
ALL CONDUIT ENTRANCES
MUST USE AN ACCEPTABLE UL
TYPE 3 CONDUIT HUB OR
EQUIVALENT TO ENSURE A
WATERPROOF CONNECTION
1.ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION
AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS.
2.ANY METAL OBJECTS WITHIN 6 FEET OF THE EXTERNAL GROUND RING
SHALL BE GROUNDED.
3.ALL GROUND CONNECTIONS SHALL BE CADWELD AND CLEANED
THOROUGHLY THEN COVERED WITH TWO (2) COATS OF SHERWIN
WILLIAMS GALVANTE PAINT B350W3 OR EQUAL. SEE 6/E-3.0 FOR
TYPICAL CONNECTIONS.
4.ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL
BE GREEN INSULATED WIRE ABOVE GROUND.
3.ALL ELECTRICAL CADWELD AND MECHANICAL CONNECTIONS SHALL
HAVE NON-OXIDATION COMPOUND APPLIED TO CONNECTION.
4.ALL MATERIALS AND CADWELD MOLDS, SHOTS, ETC. SHALL BE
FURNISHED AND INSTALLED BY CONTRACTOR UNLESS OTHERWISE
NOTED.
5.REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL
PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING
STANDARDS.
6.NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES
INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS.
7.USE PANI SCHEME FOR LOADING GROUNDS ON MGB AS DISCUSSED IN
NSTD 119, 33 & 36.
GENERAL GROUNDING NOTES
GROUNDING LEGEND
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN THAT WHICH RELATES TO T-MOBILE SERVICES ARE STRICTLY
PROHIBITED.
PROPRIETARY INFORMATION
GROUND BAR
GROUND INSPECTION WELL
COPPER GROUND ROD
CADWELD CONNECTION
SIDE SPLICE CADWELD
FIELD VERIFY & TIE INTO EXISTING GROUNDING SYSTEM
COMPRESSION LUG
1SCHEMATIC GROUNDING PLAN
22"x34" SCALE: 1/2" = 1'-0"11"x17" SCALE: 1/4" = 1'-0"
SCHEMATIC GROUNDING PLAN
E-2.0
CONNECT PROPOSED CABINETS WITH #2 BTCW TO
EXISTING MGB.7
GROUNDING KEYED NOTES
EXISTING MGB AT EQUIPMENT.2
EXISTING WATER TANK.
PROPOSED T-MOBILE ANTENNA PER PLAN, TYP.
EXISTING AGB AT ANTENNAS.
EXISTING AGB CONNECTED TO EXISTING MGB
WITH (2) #2 BTCW.
3
4
5
6
8 CONNECT PROPOSED ANTENNA AND RADIO UNIT
WITH #2 BTCW TO AGB (TYPICAL AT EACH UNIT).
4
E-3.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
4
2
7
5
3
4
8
6
ELECTRICAL DIAGRAMS
E-2.1
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.4SKU# 33965 - ALARM WIRING DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2SKU# 33965 - ONE-LINE DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1SKU# 33965 - DC POWER WIRING DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.3SKU# 33965 - AC POWER WIRING DIAGRAM
UPPER LEVEL
TERMINALS
LOWER LEVEL
TERMINALS
BLACK RED
L2L1
FIELD WIRING
24OVAC
SINGLE PHASE
60Hz 200A MAX
TOCAB
MGB
DCPP REAR VIEW
AC POWER
CONNECTIONS
SHELF 2
SHELF 1
BLK
RED
L1
L2
GRNG
MDL 1&2
TO HEATER RELAY
BLK
RED
L1
L2
GRN G
MDL 1&2
BLK
RED
3
GREEN
WIRES
240VAC DINRAIL
ASSEMBLY
3
BLK
RED
BLK
RED
BLK
RED
1OA 1OA 1OA
ON ON ON ON ON ON
CABINET
HEATER
BATTERY
HEATER OPT
EXPANSION
CABINETBLK
RED
L1
L2
BLK
RED
L1
L2MDL 3&4
GRN
MDL 5
G
MOL 5
MDL 3&4
GRNG
BLK
RED
L1
L2
BLK
RED
L1
L2
2 2 2 2 2 2
DC DISTRIBUTION-DOOR OPEN
FROM VIEW
"TIER"1 "TIER"2
THERMAL SYSREM
DAC AND HEATER
FUTURE USE
FUTURE USE
FUTURE USE
ALM 10A
DC DISTRIBUTION TERMINALS
"TIER"1 OF 4(SIDE VIEW)
DAC DOOR PWR 25A
FUTURE USE 10A
FUTURE USE 10A
FUTURE USE 10A
FRONT
1
BLK RED
1
TO CABINET DC
FUSE BLOCK
REAR
DC-48V HOT BUS
(CB FROTECTED)
DC RETURN
BUS OV(+)
1212
JUMPER JUMPER
CB AMARM
PIN AND SWITCH
ORIENTATION
"OFF"
CB AMARM
PIN AND SWITCH
ORIENTATION
"OFF"
OBSERVE CORRECT ALARM PIN ORIENTATIONMID TRIPMID TRIP
ALM 25AMID TRIP
MID TRIP
MID TRIPALM 10AALM 10AALM 10A"TIER"3 "TIER"4
THERMAL SYSREM
DAC AND HEATER
FUTURE USE
FUTURE USE
FUTURE USE
ALM 10A
JUMPER JUMPER
CB AMARM
PIN AND SWITCH
ORIENTATION
"OFF"
CB AMARM
PIN AND SWITCH
ORIENTATION
"OFF"MID TRIPMID TRIP
ALM 25AMID TRIP
MID TRIP
MID TRIPALM 10AALM 10AALM 10ANOTE:
DIAGRAMS PROVIDED ARE PER
MANUFACTURER INSTALLATION GUIDE
(E) 100A PPC
(E) CONDUIT FROM
POINT OF UTILITY
CONNECTION.
(E) (1) #4 CU, 3/4" C.
TO GROUNDING
SYSTEM (VIF)
PANEL
A
WP
(E) 100A GENERATOR
RECEPTACLE
(E) (3) #3/0 & (1) #6
GRD, 2" C (VIF)
(N) 0 AWG
GRD, 2" C
TVSS
AC FAIL
RELAY
PURCELL HPL3 600A
SITE SUPPORT CABINET
(N) PURCELL HPL3 6000A
BATTERY CABINET
(BATTERY BACKUP)
(N) (1) #2 AWG 3/4" C
TO (E) GROUNDING
SYSTEM
AL 1DOOR ALM
RTN
AL2 DAC ALM
RTN
AL3 HTR ALM
RTN
AL4 DC ALM
RTN
AL5 DC MAL
RTN
AL6 AC PWR HULOW
RTN
AL7 BAT CAB DOOR
RTN
AL8 BAT CAB DAC
RTN
AL9 BAT CAB CBALM
RTN
AL10
RTN
AL11
RTN
AL12
RTN
DC ALM
DC MIN
DC MAJ
AC MAINS HI
/LOW
ALARM
AL3
ALARM CABLE DC PP ALM RLY PIN
AL3 RTN
AL4
AL4 RTN
AL5
AL5 RTN
BLUE
BLU/WHT
ORANGE
ORG/WHT
GREEN
GRN/WHT
K10-NC
K10-C
K11-NC
K11-C
K9-NC
K9-C
73
74
76
77
70
71
GRN/WHT
GRN
ORG/WHT
ORG
BLU/WHT
BLU
BLK
RED
BLK
RED
BLK
RED
(BROWN PAIR
NOT USED)
70 71 73 74 76 77
GRN BLU
GRN
WHT BLU
WHT
ORG
ORG
WHT
DC ALARM WIRING
CODEX ALARM MODULE INSIDE
FRONT DISTRIBUTION COVER
HEATER
ALARM
HEATER
DOOR OPEN
DETECT
SWITCH
BLK
RED
C
NC
NC 1
2
C
NC NC
DOOR ALARM
SWITCH
BLK
RED
HEAT
J8 J9 J7 J6 J3 J2J4
J1
DAC
ALARM
COOLSW1
J8 J9 J7 J6 J3 J2J4
J1
DOOR ALARM
DAC ALARM 1
HEATER ALARM 1
DC POWER ALARM 1
ALARM CABLE 1
SW1
K 11K 10K 9
PURCELL HPL3
EXPANSION CABINET
TO 1/E-1.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
ELECTRICAL DIAGRAMS
E-2.222"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.2SKU# 33965 - DC HEATING AND COOLING WIRING DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.1SKU# 33965 - DC FUSE BLOCK WIRING DIAGRAM
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.3SKU# 33965 - DC CABINET DOOR LIGHT POWER WIRING DIAGRAM
LIGHT ASSEMBLY
RED
BLK
LIGHT
SWITCH
RED
BLK
BLK
BLK
RED
BLK
DOOR OPEN
DETECT
TO HEAT
CONTROLLER
FROM DIN
DISTRIBUTION
2
C
C
NC
NC
NC
NC
1
TO DOOR
UPPER FAN
TO DOOR
LOWER FAN
V+
V-
V+
V-
V +
RED
RED
RED
V -48
BLACK
BLACK
BLK
BLK RED
FROM
DC PLANT
25A
TO LED LIGHT
DC DISTRIBUTION (BLACK WIRE JUMPERS TO
FUSE POSOTIONS REMOVED FOR CLARITY)UPPER FAMLOWER FAMCAB LIGHTCOOL CONTROLLERHEAT CONTROLLER15A15A5A5A5AFROM DC DIN
DISTRIBUTION
FROM
DOOR
FROM DC DIN
DISTRIBUTION
FROM
DOOR
RED BLACK
BLACK
BLACK
RED
RED
TO HEATER
ELEMENT
ACPWR
FROM CIRCUIT
BREAKER
Door Open
Detect
HEATER
ALARMDAC
ALARM
J7
J8
J9COOL
COOL
J8 J9 J7 J8 J3 J2 J4
SW1
J1
SW1
J1
HEAT
J8 J9 J7 J8 J3 J2 J4
ALARM BLOCK
TO CABINET
DAC (COOLING) CONTROLLER
COHN FUNCTION
JI PIWR IN
J8 DELTA T JUMPER
J9 OUTSIDE TEMPETATURE
J7 DACFAN (LOWER)
J6 DACFAN (UPPER)
J3
J2
J4
ALARM
COOLING INHBIT
HEAT REQUEST
HEATER CONTROLLER
COHN FUNCTION
JI PIWR IN
J8
J9
J7 UNUSED
J6 HEATER FAN
J3
J2
J4
ALARM
COOLING INHBIT
HEAT REQUEST
DOOR SW INPUT
HEATER REALY CONTROL
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A
TYPE GTTYPE VV
TYPE GY
TYPE VS
TYPE TA
TYPE VN
TYPE GL
TYPE PT
TYPE GR
TYPE VB
TYPE NC TYPE SS
TO GROUND
RING
WEATHERPROOFING
KIT (TYP)
STANDARD GROUND
KIT (TYP) SEE NOTE.
#6 AWG
COPPER ANTENNA GROUND
BAR, ATTACHED DIRECTLY TO
TOWER WITHOUT ISOLATOR.
NO WELDING OR DRILLING
PERMITTED.
JUMPER REQUIRED ONLY
FOR 1-5/8"Ø COAX OR FOR
EASE OF CONNECTION
(TYP)
CONNECTOR
WEATHERPROOFING
KIT (TYP) SEE NOTE 2
RX2 TX1/RX1
TO ANTENNAS
ANTENNA CABLE TO
BTS EQUIPMENT (TYP)
3
E-3.0
CABLE
CONNECTOR
#6 AWG STRANDED COPPER
GROUND WIRE (GROUNDED
TO GROUND BAR). SEE NOTE
1 AND 2
CABLE GROUND KIT
WEATHERPROOFING KIT
(SEE NOTE 3)
ANTENNA CABLE
TYPICALLY
12" TO 24"
120" MAX
2 1/2"
Ø MAX
TWO HOLE LUG, BOLTED
TO GROUND BAR USING
3/8"-16x1/4" STAINLESS
STEEL HEX HEAD BOLTS
AND HARDWARE
*TWO HOLE LUG, TO BE USED WITH #2 AWG
SOLID TINNED BARE CU WIRE OR STRANDED
CU WIRE WITH GREEN, 600V, TO ANTENNA
STRUCTURE, BUILDING RING GROUND OR
MGB
COPPER GROUND BAR
ON WALL, ICE BRIDGE,
FLOOR OR ON
ANTENNA TOWER
STRANDED CU WIRE WITH GREEN, 600V,
THHN/THWN INSULATION. SIZE AS
SPECIFIED
P A N I
PANI SCHEME SPECIFICATIONS:
PRODUCER (P)
CONNECTS TO WIRELESS EQUIPMENT
CABINETS, CABLE ENTRANCE GROUND
BAR (CEGB), MAIN DISTRIBUTION FRAME
GROUND BAR (MDFB), AND STANDBY
ENGINE GENERATOR SET FRAME AND
OTHER NOISE PRODUCING EQUIPMENT.
ABSORBER (A)
CONNECTS TO THE EARTH ELECTRODE
SYSTEM INCLUDING CENTRAL OFFICE
GROUND GRID, BUILDING STRUCTURAL
GROUND, METALLIC WATER PIPE SYSTEM,
ANTENNA SUPPORTING STRUCTURE
GROUND SYSTEM, AND ELECTRICAL
SERVICE ENTRANCE GROUND.
NON-ISOLATED (N)
CONNECTS TO EQUIPMENT NOT IN AN
ISOLATED GROUND ZONE (IGZ) SUCH AS
CBN EQUIPMENT FRAME GROUNDS AND
DC GROUND CONDUCTORS FOR DC
POWER SYSTEMS THAT SERVE CBN OR
BOTH CBN AND IBN EQUIPMENT
ISOLATED (I)
CONNECTS TO THE SINGLE POINT
CONNECTION BAR (SPCB) FOR IBN
EQUIPMENT
*GROUND BARS AT BOTTOM OF
TOWERS OR MONOPOLES SHALL
USE EXOTHERMIC CONNECTION.
NEW COAXIAL GROUND KITS W/LONG
BARREL COMPRESSION DOUBLE
LUGS, ATTACH TO GROUND BAR &
INSTALL BY ANTENNA CONTRACTOR
(CADWELD TYPE-GL)
NEW 4"x20"x1/4 THK COPPER
GROUND BAR INSTALLED BY
GENERAL CONTRACTOR
#2 SOLID BARE TINNED
COPPER WIRE CADWELD
(TYPE-GL)
20" MGB OR 10" ANTENNA AGB
FIELD VERIFY 4"1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND
ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR.
2.GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE
KIT WITH TWO HOLE LUG.
3.WEATHERPROOFING SHALL BE TWO-PART TAPE KIT,
COLD SHRINK SHALL NOT BE USED.
1.DO NOT INSTALL CABLE GROUND KIT AT A BEND
AND ALWAYS DIRECT GROUND WIRE DOWN TO
ANTENNA GROUND BAR.
2.WEATHERPROOFING SHALL BE ANDREWS. (TYPE
AND PART NUMBER AS SUPPLIED OR
RECOMMENDED BY CABLE MANUFACTURER.)
1.COAT ALL MECHANICAL CONNECTIONS WITH "NOOX" OR APPROVED EQUAL.
2.ALL EXISTING & NEW TOWER GROUNDING BARS SHALL BE ATTACHED
DIRECTLY TO THE TOWER WITHOUT ISOLATORS. NO WELDING OR
DRILLING PERMITTED.
3.EXISTING HOME RUN GROUND(S) TO BE REMOVED.
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.6TYPICAL CALDWELD CONNECTIONS
22"x34" SCALE: N.T.S.11"x17" SCALE: N.T.S.5NOT USED4ANTENNA GROUND BAR
22"x34" SCALE: 1 1/2" = 1'-0"11"x17" SCALE: 3/4" = 1'-0"
3CABLE GROUNDING DETAIL
22"x34" SCALE: 2" = 1'-0"11"x17" SCALE: 1" = 1'-0"2GROUND BAR CONNNECTION
22"x34" SCALE: 1" = 1'-0"11"x17" SCALE: 1/2" = 1'-0"1GROUND BAR
22"x34" SCALE: 3/16" = 1'-0"11"x17" SCALE: 3/32" = 1'-0"
GROUNDING DETAILS
E-3.0
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
2649 S. STAR LAKE ROAD
FEDERAL WAY, WA 98003
4-9-21
PPK
RBH
1 4-9-21 PRELIMINARY ZONING PPK
2 4-26-21 FINAL ZONING PPK
3 4-28-21 PRELIMINARY CONSTRUCTION PPK
4 6-10-21 RPCD: DESIGN CHANGE PPK
5 6-24-21 RPCD: DESIGN CHANGE PPK
6 7-12-21 FINAL CONSTRUCTION PPK
APPROVAL STAMP
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072
F 425.482.2893T 425.806.1869
Sur vey ing
Engineer ing
Pla nn ing
Woodinville
1851 Central Pl S, #101
Kent, WA 98030
Kent
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
HERITAGE WOODS PARK
HGHLN WTR DT - SE52XC241
SPRINT RETAIN
SE04227A