Loading...
01-102191-00 (2)CITY OFI'jr.- �I'll, fqr5000� CITY HALL 33530 1 st Way South July 3, 2001 PO Box 9718 Dean Behse 1321 177" NE Bellevue, WA 98008 RE; Permit #01-102191-000-00-PC Dobish Cluster Subdivision Preapplication Dear Mr. Behse: (253) 661-4000 Federal Way, WA 98063-9718 Thank you for meeting with the City's Development Review Committee (DRC) on June 28, 2001, to discuss the preliminary plat requirements that will apply to the above referenced proposal. Those requirements are summarized below and enclosed with this letter. Sections of the Federal Way zoning and subdivision codes referenced herein are enclosed or were provided to you at the meeting. The items below do not include all regulations applicable to the subject proposal. In preparing a formal application, all pertinent portions of the City's codes and other regulations as applicable, must be consulted. Preapplication comments are based on a preliminary review only, and should in no way be construed to represent final comments on the proposal. As the proposal is redesigned, or more detailed plat plans and/or environmental information is prepared, additional issues or concerns . may be identified which were not covered at the meeting. Further, any revisions to Federal Way codes prior to submittal of the preliminary plat application may affect the proposal. A detailed, substantive review will be conducted after the preliminary plat application is filed. PROJECT DESCRIPTION The preapplication includes a 15-lot cluster subdivision of an 8 acre (+/-) parcel with access from Dash Point road at approximately 42"d Avenue SW. A variety of environmentally sensitive areas are known to be located on or adjacent to the site, and others are potentially located there. These include wetlands, streams, geologically hazardous areas, critical habitat, and aquifer recharge areas. The site is zoned RS 15-0 (Single Family Residential, 15,000 square feet minimum lot size). The site is surrounded by RS 15-0 zoning and single family development, except along the westerly property line, which is zoned Suburban Estates (SE) and contains the Dumas Bay Park property. PLANNING DIVISION (Lori Michaelson, 253-661-4045) 1. Subdivision Review Process: Pursuant to the City's subdivision code', preliminary plats are subject to City Council approval, following a public hearing and recommendation from the Federal Way Hearing Examiner. The proposal is also subject to environmental review under the State Environmental Policy Act (SEPA). Currently, the preliminary plat application fee is $5,334 + $58 per acre. The SEPA checklist application fee is currently $571.00. The $321.00 preapplication review fee will be credited toward the plat application fee at the time it is ' FWCC Chapter 20, Subdivisions. Dobish Cluster Subdivision Preapplication July 3, 2001 Page 2 filed. The preliminary plat application must address all submittal requirements indicated in the subdivision code and the City's information bulletin on subdivisions (enclosed), along with comments in this letter. Public noticing requirements include: notice of subdivision application, notice of environmental threshold determination, and notice of public hearing. Accordingly, the application must include a total of three (3) sets of stamped, addressed envelopes for property owners within 300 feet of the subject property. Also provide one set of stamped addressed envelopes for occupants of non owner -occupied units within 300 feet of the property. Envelopes must include the City of Federal Way return address (PO Box 9718, Federal Way, WA 98063-9718). Also, for our records, provide separate paper lists of the owners and occupants within 300 feet of the site and a corresponding parcel map showing the 300-foot radius from the site. Refer to the City's written instructions2 in obtaining, preparing, and submitting the required envelopes and accompanying information. 2. Cluster subdivision layout and design: (a) Density and minimum lotsize: Total density' (or number of lots permitted) for subdivision sites is calculated by subtracting 15 percent for required open space and 20 percent for streets from the gross land available, then dividing by the minimum lot size of the underlying zoning district. Total density for the 8 acre (+/-) site is estimated at 15 lots4. The proposed number of lots is consistent with this preliminary calculation. However, site requirements related to subdivision design, open space, environmentally sensitive areas, storm drainage provisions, etc., may affect the total number of lots that the site can accommodate. The proposal does not provide individual lot sizes, but the plan states that "some lots are 7,500 SF"; and one lot (#15) is noted at 15,000 SF. Lots ranging in size from 7,500 to 15,000 is consistent with the City's cluster subdivision provisions-5 which allow reduction in lot size by up to one-half of the underlying zoning requirement. However, many of the proposed lots, especially those adjacent to 15%+ slopes, appear to be undersized, once the 15% slope area is deducted from the lot area, as required for cluster subdivisions and more fully detailed under (b), below. (b) Key design requirements Cluster subdivisions are required to meet the following key design standards. These standards are intended to ensure single family design characteristics and compatibility with adjacent single family neighborhoods. Lotsize compatibility. Any lots in a cluster subdivision which directly abut an established single family use or zoned neighborhood, shall be no less than the neighboring lot size, or the underlying zoning minimum lot size minus 10 percent, whichever is smaller. This provision would apply to any created lots that directly abut the south and southeast property lines (against RS-15.0 zoning). However, a Native Growth Protection Tract (for slopes or other environmentally sensitive areas) providing substantial 2 Refer to the City's handout titled Procedures for Obtaining Mailing Labels. 3 Sec. 20-153, Density. 'Total site squarq footage (348,480), minus open space and streets (35%=121,968 SF), divided by 15,000=15 lots. 'See . 20-154, Cluster subdivision. * 1,_ 4 Dobish Cluster Subdivision Preapplication July 3, 2001 Page 3 property separation will be considered in meeting all or a portion of this separation requirement in lieu of increased lot sizes. Slope restrictions Cluster lots may not be created on slopes of 15 percent or greater (measured in their natural state). Therefore, these slope areas may not be included within lot area calculations. Several of the lots as proposed appear to include 15%+ slope areas, and must be revised to exclude the slope areas, while maintaining a minimum 7,500 SF area within the individual lots. Slopes 15% and greater must be set aside within a Native Growth Protection Tract on the face of the plat. usable open space. The preliminary plat drawing submitted makes no provision for open space as required by code6. Cluster subdivisions must provide 15% of the gross land area in open space, or approximately 1.2 acres for the approximate 8-acre site. All of this required open space must be usable, except up to 5 percent may be buffer. All open space is required to be set aside in a separate tract and commonly owned and maintained by the homeowners of the lots within the plat. Usable open space is defined? as areas which have appropriate topography, soils, drainage and size to be considered for development as active recreation areas. Also, usable open space must be readily identifiable, a central focus and amenity for the project, and easily accessible by residents. Playground equipment or other recreational equipment, picnic tables, etc., within usable open space is encouraged but not required. Pedestrian trails meeting the City's design standard can count towards open space requirements. Finished slopes within active recreational areas should not exceed two percent, and pedestrian trails may not exceed 8 percent. Areas defined as environmentally sensitive and their setbacks may not be included in meeting usable open space requirements. Buffer open space is intended to provide separation between properties and streets$. Usable open space design options, along with provisions for access, improvements, ownership and maintenance will be required and determined by the City at the time of application. Approval criteria: The cluster subdivision must meet specific approval criteria9, including innovative development and design elements for architectural compatibility with adjacent single family housing, with particular attention to lot size and architecture where immediately adjacent to existing neighborhoods; and protection of natural, scenic, or historic features. Community Design Guidelines10: The cluster subdivision is also subject to additional architectural standards which will be applied to the project as final plat conditions and implemented through building permit issuance ' FWCC Secs. 20-154(b)(5), and 20-155. ' FWCC Sec. 20-155(1), Usable open space. 8 FWCC 20-155(a)(3), Buffer open space. ' FWCC Sec. 20-154(c)(1) through (5). "" FWCC Sec. 22-1640, Design for cluster residential subdivision lots. Dobish Cluster Subdivision Preapplication July 3, 2001 Page 4 for individual homes. These include: (1) Garages shall be provided for all lots; (2) Front entryways shall be the prominent feature of the home; (3) Attached garages shall not compose more than 40% of the front facade if garage doors are flush with the front fagade or offset by less than five feet; (4) Detached garages shall be set back a minimum of five feet from the front facade; (5) If garage access is provided from alleys, the front yard setback can be reduced to 15 feet; and (6) Each dwelling unit shall be intended for owner occupancy. 3. EnWronmentally Sensiti ve Areas A number of environmentally sensitive areas are located on or adjacent to the site, including wetlands, streams, geologically hazardous areas, critical habitat areas, and (potentially) an aquifer recharge area. Environmentally sensitive areas are defined and regulated by the City's sensitive areas ordinance", environmental policy12, and the State Environmental Policy Act. (SEPA). Please refer to the City's information bulletin, Environmentally Sensitive Areas, for an overview of the City's regulations. It is the applicant's responsibility to locate all improvements on the property to minimize adverse impacts to environmentally sensitive areas.13 It is also the applicant's responsibility to evaluate and identify all environmentally sensitive areas, and associated setbacks as applicable. Sensitive areas (including associated setbacks where applicable) must be surveyed and delineated on the plat map. Any proposed intrusions into sensitive areas or their required setback areas must also be depicted. Any land surface modifications or any other proposed intrusion into such areas are subject to the appropriate review process and decision criteria, as detailed below. The City's determination concerning environmentally sensitive areas will be based on a review of the applicant's SEPA checklist, accompanying specialized environmental studies, and applicable code and policy requirements. Such studies must be prepared in accordance with applicable code requirements. These may include, but are not necessarily limited to, wetland and stream reports, habitat reports, geotechnical reports and/or hydrogeological reports. Refer to the City's information bulletin, Selecting a Wetland/Stream Consultantfor guidance in this selection process. The City's review of specialized studies is provided to applicants on a cost recovery basis, whereby the applicant pays for such services. A procedure is also available upon request whereby the applicant can work directly with a City -approved consultant, eliminating the need for additional consulting costs. (a) Wetlands A regulated wetland is located within the Dumas Bay property, abutting the northwest property boundary. The wetland is identified in the City's current inventory as a Class I wetland. Class I wetlands are considered to provide the greatest function and value out of the three possible classifications (I, II, III) in the City's 3-tiered classification system. The required setback for Class I wetlands is 200 feet. The applicant may accept the City's wetland classification or may commission an independent study and propose a different classification on this basis. In any case a wetland delineation is required. FWCC Article XIV, Environmentally Sensitive Areas. 12 FWCC Chapter 18, Environmental Protection. " FWCC Sec. 22-1266, Responsibility ofapplicant. Dobish Cluster Subdivision Preapplication Page 5 July 3, 2001 With certain exceptions14, or as may be permitted by the Hearing Examiner through a Process IV decision, no development activity, clearing, grading, or other land , surface modification may occur within required setback areas. Any proposed storm drainage discharge to wetlands and/or streams must be addressed in the application as a proposed intrusion, with potential adverse impacts and appropriate mitigation addressed in environmental documents. The code also has provisions for buffer averaging and buffer reductions, subject to specific decision criteria and based on the existing functions and values of the wetland and buffer. Conversely, the Director may require buffer widths to be increased if it is determined necessary to protect environmentally sensitive areas based on site -specific conditions. (b) Streams The site contains two streams as mapped on the City's environmentally sensitive areas map. One crosses the southwest corner of the site and one crosses the northerly portion of the site. Unlike wetlands, the City has no formal inventory or classification for streams. As such, the application must include a stream report and determination of whether these streams meet the code defnitionS15 of major or minor. Appropriate corresponding setbacks must be depicted on the plat map. Major streams are subject to a 100-foot setback and minor streams are subject to a 50- foot setback. As with wetlands, no land surface modification or other proposed intrusions into stream setbacks is allowed, with certain exceptions or as may be permitted by the Hearing Examiner through a Process IV decision. Any proposed storm drainage discharge to wetlands and/or streams must be addressed in the application as a proposed intrusion, with potential adverse impacts and appropriate mitigation addressed in environmental documents. (c) Geologically hazardous areas. On -site slopes and/or soils may meet one or more of the code definitions of geologically hazardous areas16, which includes erosion hazards, landslide hazards, seismic hazards, and steep slope hazard. The application must include a geotechnical report, with all areas defined as geologically hazardous depicted on the plat map. The code prohibits development activity or land surface modification within 25 feet of the top or toe of a steep slope or other geologically hazardous area, except as may be proposed by the applicant on the basis of a geotechnical report and approved by the Director of Community Development Services. Refer to the City's information bulletin, Geologically Hazardous Areas, for an overview of these regulations. (d) Fish and Wildlife Habitat Conversation Area: Based on the City's sensitive areas maps, the site or adjacent areas may contain Fish and Wildlife Habitat Conservation Areas, as defined by the City's environmental palicyl' and determined through the applicant's specialized studies and the environmental review process. The shoreline and upland areas immediately west of the site are known to contain Blue Herron habitat, breeding and nesting areas. Bald Eagle are also known to exist in the vicinity. The major wetland, streams, and associated estuarine areas adjacent to the shoreline, are expected to provide significant habitat value. The applicant's SEPA checklist must identify all such areas, and be accompanied by a wildlife and habitat analysis which addresses all project -related impacts to critical habitat areas and provides appropriate mitigation measures. The applicant's expert should solicit 14 Minor improvements such as footbridges, walkways, and benches may be permitted administratively based on decision criteria (FWCC Sec 22-1359(d)). 15 FWCC Sec. 22-1, Definitions, Major Stream, Minor Stream. 16 FWCC Chapter 18, Environmental Protection, Sec. 18-28, Additional definitions- " FWCC Sec. 18-28, Additional definitions. Dobish Cluster Subdivision Preapplication July 3, 2001 Page 6 comments from the Washington Department of Fish and Wildlife in preparing the analysis and associated recommendations. (e) Aquiferrecharge area: The site also potentially contains an aquifer recharge area, as defined by the City's environmental policy17 and determined by the applicant's specialized studies and through the environmental review process. All such areas must be mapped on the preliminary plat map. The geotechnical report must identify any such areas and address proposed impacts for protection of such resources. (f) Sensitive areas setbacks/proposed intrusions The code establishes required setbacks for streams, wetlands, and geologically hazardous areas. No code -required setbacks are established for critical habitat or aquifer recharge areas, except as may be determined necessary through an environmental analysis. As noted above, proposed intrusions into code -required setbacks for wetlands and streams are subject to approval by the Hearing Examiner. Also as noted, any proposed intrusions into geologically hazardous areas are subject to approval by the Director of Community Development. The identification and protection of any critical habitat and aquifer recharge areas, including any mitigation measures as appropriate, is determined by the Director, based on the applicant's specialized studies and the environmental review process. (9)Native Growth Protection Tracts (NGPTs) and Easements City code allows but does not stipulate whether environmentally sensitive areas shall be established in tracts or in easements The overall code and environmental objectives are to permanently preclude such areas from development activities and to protect human life and property. While easements may be preferred by applicants since they can be included in lot area calculations, in practice they have proven less effective than tracts in ensuring that these areas are protected in perpetuity. Therefore, the use of tracts is the preferred method to achieve the public objectives. However, the City will consider an easement for slopes and other geologically hazardous areas, provided that it includes clear, identifiable method(s) to distinguish it from the balance of the lot(s), with permanent fencing or proposed equivalent measures, and the accompanying easement language is comprehensive, specific, and enforceable. The applicant's easement request should be based on the recommendations of a geotechnical engineer. In addition, residential lot areas should not be significantly encumbered by any such easement, and reasonable and sufficient yard areas for homeowners' use should be maintained. 4. .Significant trees, clearing, gradIng, landscape plan A preliminary clearing and grading plan must be submitted with the preliminary plat application. The site appears to contain a fair number of trees meeting the code definition of significant18. All existing significant trees and natural vegetation must be retained on the site to be subdivided, except that which will be removed for improvements or grading as shown on approved engineering plans. The grading plan and plat layout must reflect maximum consideration to avoidance and retention of significant trees. The plat application must include an inventory of significant trees presently on site. 18 Significant trees are defined as twelve inches in diameter or 37 inches in circumference measured four and one-halffeet above ground; in good health; not diseased or dying; and do not include red alder, cottonwood, poplar or big leaf maple (FWCC Sec. 22-1, Definitions). Dobish Cluster Subdivision Preapplicituon July 3, 2001 Page 7 All trees defined as significant shall be identified and retained or replaced at the rate of at least 25 percent of the significant trees on the site. Removing significant trees that are located within areas to be developed for rights -of -way or other plat utilities are exempt from the 25 percent retention calculation. Clearing and grading of individual future lots is not permitted during construction of plat infrastructure, except in locations as may be determined by the City which present extreme topography or other unusual conditions. The preliminary plat application must include a landscape plan, prepared by a licensed landscape architect pursuant to code requirements19. The plan shall identify existing significant trees, those that are proposed to be removed, retained, or replaced; street trees along the internal plat street; landscaping around the detention pond20; and any proposed landscaping within open space areas. In addition, subdivisions along arterial streets are required to provide a 10-foot wide Type III landscape strip along all arterial streets to shield new residences from the streee'. This would apply along Dash Point Road, and shall be shown on the landscape plan. Existing trees and vegetation within the required ten -foot strip along Dash Point Road will be considered in meeting the Type III landscape requirement. 5. School bus routes and walking routes The Federal Way School District will review the preliminary plat application for school pedestrian access and circulation. As noted in the enclosed memorandum from Geri Walker, a school access analysis is required in conjunction with the preliminary plat application. Please note that school impact fees for individual residences will be charged and collected at the time of building permit issuance. School impact fees for single family residential is currently $2,710 per dwelling unit. Impact fees are subject to update on an annual basis. 6. Outside agency permits The applicant is responsible to identify and obtain any required permits from outside agencies. 7. Final plat The City currently requires a $2,044 application fee for final plats. This fee, or the fee in effect at the time of final plat application, is required to process the final plat. Substantial completion of the plat infrastructure must be accomplished prior to submittal and processing of the final plat. The City allows bonding only for uncompleted minor improvements in order to process the final plat. PUBLIC WORKS DEPARTMENT Refer to enclosed comments from Kim Scatterella, Senior Development Engineer (253-661- 4132) and Rick Perez, Traffic Engineer (253-661-4133). LAKEHAVEN UTILITY DISTRICT Please see enclosed comments from Mary Young (253-946-5400). " FWCC Sec. 20-186, 186, Landscaping protection and enhancement. 20 FWCC Sec. 20-178, Buffers. 21 FWCC Sec. 20-178(a); 22-1565(c). Dobish Cluster Subdivision Preapplicat,,,.i Page 8 July 3, 2001 FEDERAL WAY FIRE DEPARTMENT Please see enclosed comments from Greg Brozek (253-926-7241). We hope you found the preapplication process to be useful in identifying key requirements related to the proposal. As you know, this is a preliminary review only, and it does not take the place of the full review that will follow submittal of a formal application. Please contact me at 253-661-4045 if you have any questions. Sincerely, Lori Michaelson, AICP Senior Planner C: Rick Perez, Traffic Engineer Kim Scattarella, Senior Development Engineer Mary Young, Lakehaven Utility District Greg Brozek, Federal Way Fire Department End: Comments from Rick Perez, Public Works Traffic Division Comments from Kim Scattarella, Public Works Development Review Division Comments from Mary Young, Lakehaven Utility District Comments from Greg Brozek, Federal Way Fire Department Comments from Geri Walker, Federal Way School District wMMIIIL&:H� Subdivision Code (FWCC Chapter 20) Definitions (FWCC Article I) Environmental Policy (FWCC Article II) Environmentally Sensitive Areas (FWCC Article XIV) Landscaping (FWCC Article XVII) Community Design Guidelines (FWCC Article XIX) Environmental checklist Federal Way Wetland Inventory Database Sheet (W/L #43) Master land use application Meeting signup sheet Information bulletins: Preliminary Plat submittal requirements Environmentally Sensitive Areas Geologically Hazardous Areas handout Selecting a stream/wetland consultant Obtaining mailing labels Doc ID#15179 CITY fjC�-- 33.301 ST WAY SOUTH DATE: June 28, 2001 TO: Lori Michaelson, Senior Planner Kim Scattarella, Senior Development Review Engineer FROM: Rick Perez, Traffic Engineer SUBJECT: DOBISH - (01-102191-00-PC) *NO SITE ADDRESS* MEMORANDUM Public Works Department I have reviewed the project site and submitted materials and have the following comments. Transportation Impact Analysis Federal Way City Code (FWCC) Section 22-1475 authorizes the requirement of Transportation Impact Analyses to identify transportation impacts of development and identify appropriate mitigation measures. The applicants would be expected to contribute pro -rate shares towards TIP projects impacted by more than 10 peak hour trips. Mitigation improvements necessary beyond those identified in the TIP to meet the City's adopted level -of -service standard would be expected to be provided by the applicant. Based on the preliminary site plans submitted, evening peak hour trip generation is estimated at 15 trips; however, since it is unlikely that any project on the TIP would be impacted by more than 10 trips, a Transportation Impact Analysis will not be required. However, a warrant analysis, prepared by a civil engineer registered in Washington, for turn lanes on SW Dash Point Road will be required. If warranted, the applicant would be required to construct these turn lanes. Frontage Improvements Per FWCC Section 22-1474, the applicant would be expected to construct half -street improvements consistent with the planned roadway cross -sections as shown in Map III-7 of the FWCP. The planned roadway section for SW Dash Point Road is a Type K street, consisting of a 44-foot street with curb, gutter, 6-foot planting strip with street trees, 8-foot sidewalk, and street lights in a 78-foot right-of-way. Assuming a symmetrical cross-section, no additional of right-of-way would need to be dedicated, depending on slope treatment. The toe of the slope for any street widening should be dedicated, although slope easements may be considered. Any internal streets would be Type W streets, consisting of a 28-foot street with curb, gutter, 4-foot planter strip with street trees, 5-foot sidewalk and street lights in a 52-foot right-of-way. Alternatively, a Type X street may be used, which is a 20-foot wide with ditches, however, sidewalks are still required. All streets shall be dedicated to the City. If used, a Type Y street may be used abutting no more than 4 parcels and cannot exceed 150 feet in length. A Type Y street is 24-feet wide with curb, gutter, and 5-foot sidewalks on both sides in a 38-foot right-of-way. Type Y streets may be private. Per FWCC Section 22-1477, required street improvements may be modified, deferred, or waived. Written modification requests will be considered if any of the 4 criteria are met. A handout on this is attached. Access FWCC Section 22-1543 provides access standards for streets based on planned cross-section. SW Dash Point Road is Access Class 4, which permits full access as close as 150 feet. However, WAC 468-52-040 limits access on state highways in Federal Way to access spacing of 250 feet with only one access per parcel, and FWCC 22-1543(b) limits access to one per 330 feet of a given parcel. No newly created parcels should have direct access onto SW Dash Point Road. The internal streets cannot have an access within 25 feet of the curb return from the intersection of SW Dash Point Road. An intersection sight distance analysis, prepared by a civil engineer registered in Washington, will be required for the site access onto SW Dash Point Road, using AASHTO methodology and the posted speed limit of 35 mph. Circulation FWCP Policy TP21 requires collector streets every quarter -mile, block perimeters of 2640 feet, and pedestrian block perimeters of 1320 feet. However, given the topographical constraints of the site, a written request for modification will be recommended for approval I:\csdc\docs\save\85501459.doc CITY OF C� 335301 ST WAY SOUTH DATE: June 28, 2001 TO: Lori Michaelson, Senior Planner FROM: Kim Scattarella, Senior Engineering Plans Reviewer SUBJECT: DOBISH - (01-102191-00-PC) *NO SITE ADDRESS* Pre -Application Review MEMORANDUM Public Works Department After reviewing the materials submitted and a visit of the proposed site the following comments and findings address issues that need to be resolved prior to developing this site: Land Use Review 1. This project will be required to provide surface water runoff control and water quality treatment per the 1998 King County Surface Water Design Manual (KCSWDM) and the Federal Way Addendum to the KCSWDM. This project will require Targeted Drainage Review. Depending on the location of the drainage facility outflow, either Level 1 flow control (match the developed peak discharge rates to the existing site conditions peak discharge rates for 2- and 10- year return periods) or Level 2 flow control — Sensitive slope protection area, if this site discharges to a slope of greater than 15% (match the developed peak discharge rates for 5011/6 of the 2-year peak discharge rate up to the full 50- year peak flow for existing conditions) will be required. This site lies in a stream protection area and therefore measures for Water Quality Treatment shall be selected from the Resource Stream Protection Menu. 2. Flow control and water quality treatment shall apply to both onsite improvements and any frontage improvements. 3. City of Federal Way Sensitive area maps indicate that this site is in a Geologically hazardous area and also contains a wetland. FWCC Article XIV (Environmentally Sensitive Areas), Division 4, Section 22- 1286 regulates development activities within sensitive areas such as this. The outfall for the proposed drainage system must utilize Best Management Practices to minimize downstream erosion. 4. For site plan review submittal, a conceptual drainage facility should be shown on the plan to a size and configuration approximating the needs of the site. 5. A preliminary Technical Information Report CHR), consisting of a narrative addressing the 8 core and 5 special requirements outlined in the KCSWDM, shall be provided with the site plan. A downstream analysis shall be included in the narrative. The City has available 1"=100', 5-foot contour, planimetric maps that must be used for basin analysis. Contact the City of Federal Way, Surface Water Management Department for further details. Traffic/R-O-W Improvements 1. See attached Traffic Division memorandum from Rick Perez, P.E., Traffic Engineer, for traffic related items. Building Permit Review 1. A final TIR must be submitted with the building permit application. The TIR must include the signature/seal of a Professional Engineer licensed in the State of Washington. 2. The applicant must provide a geotechnical report that addresses design pavement thicknesses for the roadways. 3. Copies of the Public Works standard checklists are available upon request to assist the applicant's engineer in preparing the plans and the TIR. 4. Bonding will be required for all improvements associated with the project. The bond amount shall be 120% of the estimated cost of the improvements. Upon completion of the installation and final approval by the Public Works inspector, the bond value will be reduced to 30% of the original amount for the two-year maintenance period. An administrative fee deposit will need to accompany the bond to cover any possible legal fees in the event the bond must be called. 5. The developer will be responsible for the maintenance of the streets and storm drainage system for a two-year maintenance period. During that time the Public Works inspector will make periodic visits to assure developer's compliance with maintenance requirements. When the two-year maintenance period is completed to the satisfaction of the Public Works inspector, the bond will be released. City inspection of the facility will continue on an annual basis. 6. When topographic survey information is shown on submitted plans, the vertical datum block shall include the phrase "DATUM: N.G.V.D.-29" or DATUM: K.C.A.S." on all sheets where elevations are called out. 7. Site plans shall be drawn at a scale of 1"=20' or larger. Drawings submitted for plan review shall be printed on 24"x36" paper. Final, approved drawings shall be drafted/plotted on 24" x 36" mylar sheets with permanent black ink 8. Provide cut and fill quantities on the grading plan. Erosion control measures, per Appendix D, 1998 KCSWDM must be shown on a plan sheet. 9. The site plan should show the location of any existing and proposed utilities in the areas affected by construction. JUN-26-2001 15:18 Fr-W.S.D.—FINANCE 253 941 0442 P.02iO3 i r FEDERALI WAYr June 26, 2001 Lori Michaelson City of Federal Way 33530 1" Way South P O Box. 9718 Federal Way WA 98(()3 RE, Dobish Preliminary Plat Dear Ms. Michaelson. This letter is in response to your request for comments on the proposed 1.5-lot single-family development located west of SW Dash Point Rd at approximately 421Q Ave SW. Federal Way School District is committed to providing the best education possible for all students who reside within the District. We are concerned with all aspects of facility use and liaiitations, transportation, safety and recreational requirements that best support the education of children attending our schools. To accomplish this, we must give focus to the impact of new housing developments. Under current boundaries this development would be served by Twin Lakes Elementary, Lakota Junior High and Decatur High School. School service areas are reviewed each year and necessary boundary changes may he made to accommodate enrollment increases. Students residing in this area receive school bus transportation to all three schools. There are stops located along; SW Dash Point RD at 39t' Ave SW and 44`h Ave SW. School bus stop placement is reviewed each year. Appropriate stops are established depending on student transportation needs. Student safety must be considered for all students who would walk to the schools and to school bus stops from this development. Sidewalks and other planning features that assure safe walking conditions for students are factors the district must consider as we comment on new development within our service areas. We ask that the develolxx work with our staff to prepare a "School Access Analysis" to the elementary, junior high and senior hich schools from this proposed development. Attached are guidelines for preparing this analysis. The developer can request additional information from Carolyn Calhoon, Assistant Transportation Director, at 945-5964 or Geri Walker at 945-2071 The most recent Federal Way School District Capital Facilities flan indicates a student yield of .6017 from single-family housing. This development could add 9 to 10 new students. These are averages only, the actual number of students may vary. This may create a need for additional space, cgtrlptr:ent and staff_ This impact is mitigated by the collection of impact fees. The District appreciates the opportunity to comment on this proposed development and reserves the right for further couunent as additional information becomes available. Since ly, . OGAlle_ 'ri Walker MIS Specialist c Jcri Carlson, Budget and Planning, Manager Rick LaBoync, Assistant disk Manager Carolyn C:alhoon, Assistant Transportation Director School Princ:ipils Phone (253) 945-2000 • 31405 18th Avenue South • Federal Way, WA 98003-543.3 • www_fwsd-wedziet,edL1 JUN-26-2001 15:18 F--(�.S.D.—FINANCE 253 941 0442 P.03iO3 School Access Analysis New development creates a need for analysis of student pedestrian safety. The Federal Way School District would prefer an analysis of walking paths to schools and bus stops from new subdivisions be prepared by the developer prior to final comments on impacts. Generally a walking route should be planned to assure that school -age pedestrians from a neighborhood: • Cross the fewest number of streets to reduce vehicle -pedestrian exposures • Walk on sidewalks or paths where available; ■ Walk the shortest possible distance on streets without sidewalks or wide shoulders; • Walk on the left side of the road facing traffic on streets where practicable; • Avoid high speed, high volume roads and roads with high truck volume. ■ Make maximum use of protective techniques (traffic control devices, existing crossing guards and school patrols.) • Use easements with walkways through parks or other available areas where student safety is maximized. Walkways and paths must be cleared of vegetation for maximum visibility. The analysis of walking paths to schools and school bus stop locations from a new subdivision should include the following information: • School location Description of sidewalks, pedestrian paths and shoulders including: condition and width of shoulder and sidewalks; Y whether shoulders are paved, gravel or grass, or nonexistent; Y whether sidewalks and pathways are immediately adjacent to the traffic lanes or are separated by a planting ship or other means from moving traffic; and the location of drainage or irrigation ditches_ • Location of all crosswalks, including type of crossing protection offered; • Medians, pedestrian refuge islands and other pedestrian safety features; • Posted speed limits and warning signs, especially all 20 mph school speed limit zones; • All stop and yield signs; • Traffic signals including presence of marked crosswalks and pedestrian signal indication Traffic signal timing and phasing for pedestrian crossing. • Major sight line obstructions as measured from the height of children. • Bicycle lanes or paths. • Other relevant pedestrian safety factors observed. TOTAL P.03 ID o 3 o c w m •� N N 09 3 m O L U N� 3 tff m m m m m m m V O a co m C m ,.. � .0.0 .0 O O •00 CL y V0- T coE m E 0 =: m.. m ?n, m m m ai m c m Y L D co a 0 c O o F- E N c>O E J C OT •N E o D E> $ CD m a c •o W m o c f.'..• H �a % C O l6 b a 'a am El0 EW O �SO) oL o 10 cm mC C�c mc 3 3 CD E 2 . -1 E L= N oe C O c `p v Q C a0i d J n O pl m C tL y •CQC •�- •�-• a n t m m 0 m L6 CD•:_ m 01 fC > > C p L m m 'O W r .0-- m k, m U L N EO r o° C L N O 3 O m N iC C E t O m .L. C N C C c m O a O C O m co m S O(D d O J C AD m 0 a N N m N fG m 0_ N O m •<{:�L^.�: >. v T.j, uk m __ H m >_ J N l6 > U N N m «� v _� m 0 m C C = -• m k (') W m N y -"� "CQC co L7 U' ?J "Q (6 H �C l4 � 8 3 E l �p U m J C _7J X m O C (6 N 7 w [6 = Q A m � >J > �$ p 7 pC 8-9 •� ;�• - _____ W. ti L tn. O C C O C m C m O O (D a a 303 `'v) C C C D r5 O (h m b O N D C 3 p L m J U@ o co D C >` E t0 7 v E m N C m'f�F. m O le m f. 0 d y0 J 'S a N m O N 3 C E cli •5 N m " N N N G. ([ 07 c 0 c co O to �fnpfA() gn p fn p2g� O O�OO 2 : a LL a W Cl) n aa (L a lo n CO LL W w Q f� (p LL LL ) LL Wn- - aCLaa a-a a aCL aa a aa. a_ a CO) O O O U) n > n U)>> CO •(n >> > n cA COjOO N N O N N LO N N N Or '. LO LLO LO 01 . (D: CO N : '- 00 r O M O O T- L- N O r_ � M �' 00 M O L\ r Cl) Lq (D o (h � O O O O O O O O r O O M r M O O O (D O O O O ti O O O O O O O O O O O O O O O O O Cl O 0 00 O O 000 Cn M (D M 000 M (OD O O O u r CO M 11y r M C\l C0 N--^ r (O r N ..'. M Lo L� 00 r O M (D N O r r- 00 O CO r r r LO .a • ••�•• ; �_ ...� .a M M (M M (M M CO M M _•'"• N ' N N N N I r N N r N O r N r N T N r N r r N N r N r N r N " CO ' co 00 O (n r r r r r r r Y!' r r N N r r N r N r N r } Q } Q } Q } } Q Q } } d Q } Q } Q >- Q PAW } Q } ] d d } Q } } C]C U- U-LL. LL Q Q LL U-LL LL U- LL U. LL r y <•.'; w ;'tip W M LAKEHAVEN UTILITY DISTRICT 316271st Avenue South ♦ P. O. Box 4249 ♦ Federal Way, WA 98063 COMMUNITY DEVELOPMENT TECHNICAL REVIEW COMMITTEE AGENDA OF: June 28, 2001 ATTN: Ms. Lori Michaelson Senior Planner SUBJECT: Agenda Item No. 1 - Dobish Cluster Subdivision 01-102191-00 (PRE) COMMENTS: Water: This property is located within the water service area of the City of Tacoma. Sewer: A developer extension agreement will be required to extend mainline sewer facilities to serve the site. It seems likely that a pressure sewer system will need to be designed. It is recommended that the Owner apply separately to the District for this process at the same time formal application is submitted to the City of Federal Way to avoid delays in construction. Please allow 3 to 4 months for plan review and approval. General: The District's Capital Facilities Charges are calculated on the basis of Equivalent Residential Units (ERU). One (1) single-family lot is equal to one (1) ERU. The District's current Capital Facilities Charge for sewer is $2,720/ERU. �: MatYE. Yung U Development Service Supervisor Direct Line: (253) 946-5400 FAX: (253) 529-4081 E-mail: myoung@lakehaven.org Date: D 1 d 0--3, L,5,o '9 o ® , :�5, 3. �• 1 0 � � n SW 308T� m LOT , 0 Q LOT 2 F� o LOT C) } r. J, LO r a`L0T 2 a / PRIVATE �* PU1�4P ST m W� o 4 DU MAS BAY PAR K „ LAKEHAVEN UTILITY DISTRICT FLUSHING o 46 STATION #23 - PR VATS PU P ST �� 3 rep T p ,o � nQc,N r 1C,FORCE J $ LOT I l YN; /•i I s W :, } sT. 1 s -- 10 '`AD c_ yy C' pDiNT ROAD cc b 0 OPEN MEA 0EO Tv C IR C OPEN MEA -au IV ,n 1 jZgr C0 .V"P M ST e #3 0 du;> r. P f3 S !4 N S t R 20 2i ,5 }0 ry w ar 16 v, 77 Ii 17 75 h -0 70 � }7 69 /7� y 5a -A ER Q4 t, „ 91 Bp,51N 20 EE Y 65 e• S_ 4 44 6s 119 }1 i4 4^ W' 3PON / t9E 47 id4 194 P61 41 46 7ySy ' `G f f 194 // 4 I// 40 f ,�~ 252 TECHNICAL REVIEW (RESIDENTIAL) Agenda Date: June 28, 2001 Subject: Dobish Subdivision/01-102191-PC/Michaelson To: Development Review Committee From: Greg Brozek — Federal Way Fire Department WATER SUPPLIES FOR FIRE PROTECTION A Certificate of Water Availability shall be provided indicating the fire flow available at the site. Fire hydrants shall be spaced 700 ft. or less apart. Every building lot shall have a fire hydrant within 350 ft. All measurements shall be made as vehicular travel distance. Fire hydrants shall be in service PRIOR to and during construction. FIRE APPARATUS ACCESS ROADWAY Fire apparatus access roadways shall be required for every building when any portion of an exterior wall of the first story is located more than 150 ft. from fire apparatus vehicle access. Fire apparatus access roads: 1) Shall have an unobstructed width of not less than 20 feet and an unobstructed vertical clearance of not less than 13 feet 6 inches. 2) Shall be designed and maintained to support the imposed load of a 25 ton fire apparatus and shall be provided with a surface so as to provide all- weather driving capabilities. 3) Shall be not less than a 20 foot inside turning radius and not less than a 40 foot outside turning radius. 4) With a dead-end in excess of 150 feet in length shall be provided with a cul-de-sac or Fire De artment approved alternative at the dead end. All such cul-de-sacs shall be not less than 80 feet in diameter. 1 5) Gradient shall not exceed 15 percent. 6) Serving a single residential property which have a dead end in excess of 150 feet in length shall be provided with a turn around approved by the chief. [K.C.F.D.#39 Administrative Policy Guideline No. 10061 EXCEPTION: When buildings are completely protected with an approved automatic fire sprinkler system, these provisions may be modified by the chief. Fire apparatus access road gates shall comply with K.C.F.D. #39 Administrative Policy Guideline No. 1001 (copy attached). AUTOMATIC FIRE SPRINKLER SYSTEMS An automatic fire sprinkler system shall be installed in Group R, Division 3 occupancies: 1) When the occupancy exceeds 2,500 square feet (including attached garages) without adequate fire flow. 2) Without approved fire department access. 3) When the occupancy exceeds 10,000 square feet. 4) When the building is classified as an over -water structure. Comments: The minimum fire flow for one- and two-family dwellings shall be 1,000 gallons per minute. If the slope of a building lot does not allow the building(s) on the site to comply with the "life safety/rescue access" requirement. the building(s) shall be provided with an approved automatic fire sprinkler system. Life safety/rescue access shall mean an unobstructed access to all floor levels and each roof level of a building on not less than 20 percent of the building perimeter by utilizing a 35-foot ladder. An alternate method would be at least one stairway enclosure with exit doorways from each floor level and with a door opening onto each roof level which conforms to the requirements of the Uniform Buildinq Code. THESE COMMENTS ARE VALID FOR 180 DAYS FROM REVIEW AND ONLY FOR THE PLANS REVIEWED. 2 Greg Brozek — Assistant Fire Marshal 31617 1 Avenue South Federal Way, WA 98003 Phone 253-946-7241 Fax 253-529-7206 SIGN IN SHEET PRE -APPLICATION CONFERENCE Project: Dobish Cluster Subdivision Preapplication DATE. 6 28 01 FILE NO.: 01-102191 (PC) NAME REPRESENTING TELEPHONE/ 5_7 7JA-- 9`53 - c(L6 - `LOR q;t --2 ,) -3 �r 1U4R a xIC LAK6PA V F r«rT 1 rsrr�r r zs -4��-S oa IM rw �� ,c �d✓�s zs3- 661 - 13Z ". R,rlc Pefe-g_ rkl f wblic, GJorf-s I?- Page 1 of 1 Lori Michaelson - DRC - Dobish Cluster Subdivision From: Kim Scattarella To: Rick Perez Date: 611910111:40 AM Subject: DRC - Dobish Cluster Subdivision CC: Jim Femling; Lori Michaelson; Sarady Long There is the question about the proposed access to Dash Point Road, just east of44th Ave. 5W. The alignmentofthe access road Ca cu 1-de-sac) for this 10-15 lot su bd ivision needs to be revised to ma ke it closer to peTend icular to Dash Point Rd. The possibility of relocating this poirntofaccess would also be a problem because ofsightdistance limitations. The other issue is that the proposed road would encroach on an existing private driveway. The only other alternative location might be access off of 44th Ave. 5W. Do you have any other comments? Oince Hazem probably won't be there, will it be you or Sarady ?) if you need plans or more information, see Lori or myself Ki m pile://C:\Windows\TEMP\GW) 00002.HTM 6/19/01 Page 1 of 1 Lori Michaelson - Dobish Cluster Subdivison Stream Classification From: Kim 5cattarella To: Lori Michaelson Date: 612010111:19 AM Subject: Dobish Cluster5ubdivi50n Stream Classification CC: Fe!Tang; Paul Bucich Kevin Peterson mentioned that he doesn't thin kthere isarn actual Stream Classification map for Federal Way at this time, but i understand that there is will be development aFsuch an i nveoory. The Sensitive Areas map shows the two streams that Flow through this site, but do not Classify them. If 5WM has any additional information aboutthis, theywilI know that you are interested in Finding out in time for the DRC meeting tomorrow. The latest Water Quality Applications map shows this area as a Resou rce Stream Protection Area for water quality treatment. Kim file://C:\Windows\TEMP\GW } 00001.HTM 6/20/01 CITY OF G 'NRI June 7, 2001 CITY HALL 33530 1 st Way South PO Box 9718 Dean P. Behse 1321 177Th NE Bellevue, WA 98008 RE: Permit #01-102191-000-00-PC Dobish Subdivision Preapplication SW Dash Point Road at 42"d SW Dear Mr. Behse: (253) 661-4000 Federal Way, WA 98063-9718 The above referenced preapplication has been assigned to me as project planner. At this time, your preapplication has been routed to members of the city's Development Review Committee. A meeting with project proponent(s) and the Development Review Committee has been scheduled as follows: Thursday, June 28, 2001, 9:00 a.m. Mt. Adams Conference Room City Hall, First floor 33530 First Way South PO Box 9718 Federal Way, wA 98063-9718 We look forward to meeting with you at that time. Please let me know if you will have more than four people attending the meeting so we can arrange for a larger room. Please call me at 253-661-4045 if you have any questions. Sincerely, C�; Lori Michaelson, AICP Senior Planner Doc.I.D. /4%9—+ CITY OF FEDERAL WAY DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES DEVEL PMENT REVIEW COMMITTEE TRANSMITTAL DATE June 7, 2001 Ta Jim Femling, Development Services Manager Mary Kate Gaviglio, Building Official Mary Young, Lakehaven Utility District Greg Brozek, Federal Way Fire Department FROM. Lori Michaelson FOR DRCMTG, ON: Internal review: June 21, 2001 Meeting with applicant: June 28, 2001— 9:00 a.m. ,FILE NUMBER(s): 01-102191-00- PC RELATED FILE NOS.: None PROJECT NAME DOBISH CLUSTER SUBDIVISION PROJECTADDRESS.' SW Dash Point Road at approximately 42"d Ave SW ZONING DISTRICT.' RS 15.0 PROJECTDESCRIPTION. PRE -APPLICATION - for the review of a proposal for cluster subjivision of (4) parcels (112103-9013, 112103-9014, 112103-9038, 112103-9056) LAND USE PERMITS.' PROJECT CONTACT; Preliminary Plat, SEPA DEAN P. BEHSE 1321177TH NE (425)747-3889 (Work) MATERIALSSUBA07TED: Preliminary Plat conceptual drawing MASTEIR AND USE APPLICATION REGE! VEC) BY V�PnRrhe�T OF CorvMu�1TY D 3PMENT SERVICES Gfffor �UNIWDEVELOPMEWAR3350 First Way South PO Box 9718 ` /.y� Federal Way WA 98063-9718 // a, 253-661-4000; Fax 253-661-4129 ARPl°/ a 7� www.ci.federal-way.wa.us APPLICATION NO(S) ol _ • �`� DD PC Date Project Name .— 00 Property Address/Location� T N C. . S A- " +� er 1,04C.. _ S Parcel Number(s) a 3 a 3 4iO.T4 Project Description 7�1V15[ ov� Type of Permit Required Annexation Binding Site Plan 13oundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Directors Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiners Decision) Process V (Quasi -Judicial Rezone) Process VI _ SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information /_/ .TQ43 0 Zoning Designation S 1 Comprehensive Plan Designation `- V a l uc of Existing Improvements 1j-DU444/DValue of Proposed Improvements Uniform Building Code (UBC): 5 I /V 4- le , L ccupancy Type 1� N Construction Type Applicant Name: Address: City/State: !$ LL. I;a ♦/G� J Zip: O d Phone: y S' — 7 y 6— Fax: [i/ ,Z T_ 3 '7 3 / 7 y Email: L m o o r3 i 5 H(2& 4 tZ i-W A, i NI< ,/v E r Signature: Agent (if Different than Applicant) Name: T-" jF- i4 ri /� . Z AF-1+ SE / Address: / 3 7. / e7 P; nV`�/ City/State: 73 .L �- E- V 0 Zip: Phone: y 3 Fax: 7— 7 N 7 2 / Email: p ,Z, rU 1� /YI S /l/. L 6 n•t Signature: Owner Name: ,L Gj / S 0 0 J3I S )-/ Address: / At 3 / S" N 6 / A N �'� " City/State: Zip: el a Phone: A/ 7. - 7 Fax: 4 f:X- 3 "! 3 1 /7 z Email: L ^I Lhd $ iJ M @ Th/ t / nl K , A/ E- r Signature:-Z�� --37 � Bulletin ##003 — October 30, 2000 Page 1 k:\Handouts — Revised\Master Land Use Application +i s IL 4 t Vie'' r`i kin'. ' 4 yy. � • �• • �,c.'� � • fir. ^��' _ .� .n�..y�•y�,, _ { '�'� �iR �� �• •.!.AAA";:; � _. .+ ..,,. r. - •r