Loading...
17-104972CITY OF 1. Federal Way November 13, 2017 F i L CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com Jim Ferrell, Mayor Jessica Pompa jpompa@md7.com MD7 LLC 10590 West Ocean Air Drive, Suite 300 San Diego, CA 92130 RE: File #17-104972 -UP; PROCESS I `DIRECTOR'S APPROVAL' SE52XC364 Mirror Lake Federal Way — Sprint, 30911 Pacific Hwy South, Federal Way Dear Ms. Pompa: The City of Federal Way's Department of Community Development has completed an administrative review of the proposed eligible facilities request to modify an existing wireless facility located at 30911 Pacific Highway South. The proposal includes: antenna replacement on an existing 150-foot tall monopole, and modify associated ground equipment for the existing Personal Wireless Facility (PWSF) located at the above -mentioned address. The proposed modifications include: remove four antennas and replace with three new antennas and remove and replace two equipment cabinets as detailed in your plans and project description submitted to the City on October 16, 2017. Changes to ground equipment are all occurring within a fenced enclosure. The Process I application was submitted and determined to be complete on October 16, 2017. The eligible facilities request is found to be consistent with the provisions of the Spectrum Act and does not exceed the substantial change thresholds. The Process I proposal is hereby approved based on the following statements of fact. Criteria 1 For facilities outside of public rights -of -way, the modification does not increase the height of the tower by more than 10%, or by the height of one additional antenna array with separation from the nearest existing antenna not to exceed twenty feet, whichever is greater. Staff Response — Based on the elevation plan, there is no height increase. This criterion is met. Criteria 2 For structures outside of public rights -of -way, the modification does not protrude from the edge of the structure more than 20 feet, or more than the width of the structure at the level of the appurtenance, whichever is greater. Staff Response — Based on the elevation and site plan there is no increase in the width of the structure. This criterion is met. Criteria 3 If the installation includes new equipment cabinets, the modification does not include the installation of more than four equipment cabinets. Ms. Pompa November 13, 2017 Page 2 Staff Response — Two new equipment cabinets are proposed, and will replace two existing cabinets inside an existing fenced enclosure area. This criterion is met. Criteria 4 For all existing facilities, the modification does not include excavation or equipment installation outside the current site of the structure or base station. Staff Response — All proposed modifications are within the existing fenced enclosure area. No excavation or equipment will be installed outside the existing base station. This criterion is met. Criteria 5 If the facility requires screening methods, the proposed modification does not defeat the existing concealment elements of the tower or base station. Staff Response — There are no screening methods for the existing monopole. Screening methods for the ground equipment will not change. Current screening methods are not defeated as a result of this proposal. This criterion is inet. Criteria 6 The modification may not violate any of the conditions of approval associated with prior approvals. Staff Response — The proposal does not violate any known conditions associated with prior approvals of the tower or site. This criterion is met. PERMIT ISSUANCE REQUIRED Prior to any site work, an electrical permit may be required from the City's Building Division. For further information regarding the need for an electrical permit, please contact the department's Permit Center at permitcenter@,cityoffederalway.com or 253-835-2607. APPEALS The effective date of this decision is November 16, 2017, or three days from the date of this letter. Pursuant to FWRC 19.55.050, any person who received notice of the administrative decision may appeal this decision to the Federal Way Hearing Examiner within 14 calendar days, or by November 30, 2017. Any appeal must be in the form of a letter delivered to the Department of Community Development with the established fee. The appeal letter must contain a clear reference to the matter being appealed and a statement of the alleged errors in the director's decision, including the identification of specific findings and conclusions made by the director, disputed by the person filing. You may waive your right to appeal, if desired, by writing the city a letter to this effect. APPROVAL DURATION Unless modified or appealed, the Process I decision is valid for one year from the date of issuance of the decision. A one-year time extension to the decision may be requested prior to the lapse of approval following the provisions listed in FWRC 19.15.110. The improvements must be substantially completed within the one-year time period, or the land use decision becomes void. 17-104972-00-U P Doe. I D. 76831 Ms. Pompa November 13, 2017 Page 3 CLOSING This land use decision does not waive compliance with future City of Federal Way codes, policies, and standards relating to this development. If you have any questions regarding this decision, please contact Senior Planner Jim Harris at 253-835-2652, orjim.harris@cityoffederalway.com. Sincerely, 1 V1 z Brian Davis Community Development Director Ref: Approved Site Plan and Elevation sheets A-1 A-4, dated 9/22/17 by MD7 c: Jim Harris, Senior Planner 17-104972-00-UP Doe LD 76831 Sprint Site Modification to Facility SE52XC364 - 30911 Pacific Highway South Statement of Compliance with 20.20.195 Communication, Broadcast and Relay Facilities Project Description: Sprint is proposing to modify an existing wireless facility located at 30911 Pacific Hwy S. Federal Way, WA 98003. The proposal consists of the replacement of removing (4) € antennas and replacing with (3) (N) Tri-Band antennas. Removing (4)(E) RRUs and replacing with (3) (N) 2500 MHz RRUs. Installing (6) (N) 800 MHz RRUs with (3) (N) 1900 MHz RRUs. Removing (E) Cabinet. Installing (N) ECAB/BCAB Modular Cabinet with (N) GPS Antenna. Installing (N) PPC and (N) Telco Cabinet on (N) H-Frame. Removing (E) Cables and installing (4) (N) Hybrid Cable. Eligible Facility Request This project includes the collocation of new transmission equipment on an existing monopole and the replacement of transmission equipment As such, it qualifies as an eligible facility request under Section 6409(a) of the Middle Class Tax Relief and Job Creation Act of 2012. Further, none of the scope of work exceeds the standards for a "substantial increase in size." The definition of "substantial increase in size" can be found in the Nationwide Programmatic Agreement for the Collocation of Wireless Antennas (47 C.F.R. Part 1, App. B), and has been adopted by the FCC for use in interpreting Section 6409. The thresholds are the greater of: • Height increases of more than 10% or 20 feet • Horizontal equipment protrusions of 20 feet or the width of the structure These standards are also recognized in state law, in the revision of SEPA to include these sorts of collocations in the list of exemptions. See RCW 43.21C.0384. SEC. 6409. WIRELESS FACILITIES DEPLOYMENT_ (a) FACILITY MODIFICATIONS. (1) IN GENERAL. Notwithstanding section 704 of the Telecommunications Act of 1996 (Public Law 104-104) or any other provision of law, a State or local government may not deny, and shall approve, any eligible facilities request for a modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. (2) ) ELIGIBLE FACILITIES REQUEST. For purposes of this subsection, the term "eligible facilities request" means any request for modification of an existing wireless tower or base station that involves — (A) collocation of new transmission equipment; (B) removal of transmission equipment; or (C) replacement of transmission equipment. RECEIVED OCT 16 2017 CITY OF FEDERAL WAY CQMMUNfTY DEVELOPMENT (3) APPLICABILITY OF ENVIRONMENTAL LAWS. Nothing in paragraph (1) shall be construed to relieve the Commission from the requirements of the National Historic Preservation Act or the National Environmental Policy Act of 1969. CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: October 24, 2017 TO: Cole Elliott, Development Services Manager Peter Lawrence, Plans Examiner Rick Perez, City Traffic Engineer Brian Asbury, Lakehaven Water & Sewer District Chris Cahan, South King Fire & Rescue FROM: Jim Harris 253 835 - 2652 FOR DRC MTG. ON: November 2, 2017 FILE NUMBER(s): 17-104972-00-UP RELATED FILE NOS.: None PROJECT NAME: SE52XC364 MIRROR LAKE - SPRINT PROJECT ADDRESS: 30911 PACIFIC HWY S ZONING DISTRICT: BC PROJECT DESCRIPTION: Modify an existing wireless facility to include replacement of antennas, cabinets and cables LAND USE PERMITS: PROJECT CONTACT: JESSICA POMPA MATERIALS SUBMITTED: Preliminary Plans Project Description Licensor Site Name/Number: Federal Way #2, WA/ 82957 Licensee Site Name/Number: WA-TAC-161-A/Federal Way SCHEDULE LICENSE OIL' SPACE This Schedule is executed and delivered pursuant to that certain Master Tower Space License Agreement between Licensor and Licensee dated December 14, 2004 (the LOAgreement"). All terms and conditions of the Agreement are incorporated herein by reference and made a part hereof for all purposes. The following space shall be licensed on the terms indicated below: Licensee Information: Licensee's Name: Clearwire, LLC, a Nevada limited liability company Notice Address: Clearwire, LLC 5808 Lake Washington Blvd. Suite 300 Kirkland, WA 98033 Attn: Ana Hemmert Contact Name: Contact Number: Fax Number: Licensor Information: Notice Address: Contact Name: Contact Number: Fax Number: Property Management (425) 216-7600 (425) 216-7900 American Tower Delaware Corporation c/o American Tower Corporation 10 Presidential Way Woburn, MA 01801 Contracts Manager (781) 926-4500 (781) 926-4555 Remittance Address: American Tower Delaware Corporation c/o American Tower Corporation Dept. 5305 P.O. Box 30000 Hartford, CT 06150-5305 Tower rnfortuation: Licensors Tower Name: Federal Way #2 Coordinates: 47-19-29 N 122-18-48 W Licensees Tower Number: 82957 Licensee's Tower Name: American — Federal Way Licensee's Tower Number: E Licensoes Contract Number: TBD Licensee Pees and Terris: License Commencement Date: The ea 9ier of: i commencement of installation of Licensee's cAuipment, or (ii) July 1, 2006. Refer to Section 4.2 of the Agreement for the duration of the Term (including renewal periods) and Section 6.1 of the Agreement for the annual escalation of the License Fee. Licensor Site Name/Ntt bur: Federal Way 02, WA/ 82957 Licensee Site Name/Nurnber: WA-TAC-16 I-A/Federal Way All other Fees includin but not limited to the Site Inspection Fee and Administrative Fees shall increase as set forth in Section 6. t of the Agreement. Licensee Equipment Inforination: Licensee's Equipment and its location at the Site are as set forth in Exhibit A, which is incorporated herein by reference and made a pail hereof. Site Drawings are attached hereto as EAlblt B. ❑they Proyisinns: a) Licensor and Licensee agree and acknowledge that Licensee shall bundle its transmission lines. b) Licensor and Licensee agree and acknowledge that this Agreement is contingent upon AirTouch Communications, Inc. and/or its Affiliates' Right of First Refusal. c) The "Rider # 1 to Master License Agreement for AirTouch Subleased Towers" attached hereto as EXHIBIT C is hereby incorporated into this Agreement in its entirety and the terms and condition contained therein shall supersede any contradictory provision in this Agreement. d) Notwithstanding anything to the contrary in this Agreement, the offer expressed to Licensee in this Agreement shalt automatically become null and void with no further obligation by either party hereto if a structural analysis of the Site completed after the execution of this Agreement by Licensor but before the commencement of the installation of Licensee's Approved Equipment indicates that the Site is not suitable for Licensee's Approved Equipment unless Licensor and Licensee mutually agree that structural modifications or repairs shall be made to the Site on mutually agreeable terms. [SIGNATURES ARE ON THE NEXT PAGE] [REMAINDER OF THIS PAGE LEFT INTENTIONALLY BLANK] Agreed to and Accepted by: LICENSEE: Clearwire, LLC, a Nevada limited liability company By: Name: John Storch Title: VP Network Development Date: t Licensor Site Name/Number: Federal Way #2, WA/ 82957 Licensee Site Name/Number: WA-TAC-161-A/Federal Way Agreed to and Accepted by: LICENSOR: American Tower Delaware Corporation, a Delaware corporation, a wholly owned subsidiary of American Tower Corporation, a Delaware ZcorporationBy: Name:'r-c+ s } r Title: Date: -5- /z-L006 The offer of license expressed in this Schedule shall automatically expire and become void if not accepted by Licensee and such acceptance received by Licensor within twenty (20) Business Days from the Offer Date as defined in the Agreement. This Schedule does not constitute Licensed Space until completed and executed by both parties. Licensor Site Name/Number: Federal Way #2, WA/ 82957 Licensee SiteName/Nutnber: WA-TAC- 161 -A/Federal Way EXHIBIT A List of Permitted Equipment 1 Licensor Site Name/Nutnber: Federal Way #2, WA/ 82957 Licensee Site Name/Number: WA-TAC- 161 -A/Federal Way EXHIBIT C RIDER # 1 RIDER FOR AiRTOUCH SUBLEASED SITES (This Rider is non-negotiable) Licensee and Licensor have entered into the attached license agreement to a master license agreement or independent site license agreement, as applicable ("Agreement"). Licensee acknowledges that Licensor's rights with respect to the use and further sublicense of the communication tower and site ('"Tower Site") under the Agreement are subleased from AirTouch Communications, Inc. and/or its Affiliates ("Air Touch") and are subject to a sublease agreement (as amended from time to time) ("AirTouch Sublease") between Licensor and AirTouch, pursuant to which Licensor subleases a portion of the Tower Site from AirTouch as Licensor's overlandlord. Pursuant to the AirTouch Sublease, Licensor is obligated to obtain Licensee's agreement to the following provisions, which provisions may not be superseded, altered or amended by the Agreement (including any conflicting or inconsistent provisions in the Agreement) or any attachment, exhibit, amendment, supplement, schedule, or other written instrument associated with the Tower Site or the Agreement: a) Ground Lease/AirTouch Sublease: The Agreement shall be subordinate to the terms and conditions of any underlying easement, ground lease, license, permit, tight of way or similar use right between the land owner or lessor and AirTouch ("Ground Lease") and any and all references to the Ground Lease in the Agreement shall be deemed to refer only to (lie Ground Lease (a copy of which Licensor shall provide to Licensee following a written request and redacted as Licensor deems reasonably necessary) and not the AirTouch Sublease. In the event that a default or non-compliance with a provision of the Ciround Lease is caused by Licensee, Licensee shall, upon Licenser's written request at Licensee's sole expense, cure or otherwise Mmedy such default or non-compliance within the tune period provided for pursuant to the Ground Lease. Licensor may not be able to cause AirTouch or any underlying landowner or lessor to record a copy of any underlying ground lease, license, easement or other right of use associated with the Tower Site, particularly where such recordation is prohibited under the terms of the Ground Lease. Licensor is not authorized to provide Licensee with a copy of the AirTouch Sublease; provided, however, Licensor (i) shall be obligated to exercise any renewal options available to it under the AirTouch Sublease and to cause AirTouch to exercise any renewal options available under the Ground Lease during the initial and all renewal terms under the Agreement, and (ii) agrees not to take any action with respect to the AirTouch Sublease which will cause the AirTouch Sublease to be prematurely terminated. b) Interference: In addition to the rights and obligations of Licensor and Licensee as set forth in interference section of the Agreement, in the event that equipment operated by Licensee at tite Tower Site as permitted under the Agreement ("Licensee's Equipment') is suspected to be causing interference with AirTouch's then -current use of the Tower Site, Licensee may be required to conduct a transmit test jointly with AirTouch (and shall notify AirTouch in writing five (5) business days prior to such transmit test as to the date and time such test will commence) to measure: i. The signal transmit levels at the output after the final filter stage on Licensee's transmit line with all transmitters keyed up at maximum power; ii. Antenna isolation between the output of the final filter stage on Licensee's transmit line and input line to Ah Tottch's multicoupler in AirTouch's frequency band of operation; and iii. The combination of (i) worst case level measured out of Licensee's transmit line added to (ii) worst case antenna isolation. Such value shall be no greater than - 120dBm. c) If AirTouch determines that it is experiencing interference as a result of such tests, AirTouch or Licensor shall notify Licensee to immediately cease the transmit test and Licensee shall cease such test. Licensee shall be responsible for ensuring that proper filtering and isolation are in place for . 1 Licensor Site Name/Number: Federal Way ##2, WA/ 82957 Licensee Site Name/Number: WA-TAC- 161 -A/Federal Way the transmit test and operation of Licensee's antenna system. Licensee may not install or change, alter or improve the frequency, power, type of Licensee's Equipment such that it (i) interferes with or might interfere with the pre-existing operation of AirTouch's equipment on or about the Tower Site, (ii) is not authorized by any applicable federal, state, or local law, tole, regulation, ordinance or order, or (iii) is not made or installed in accordance with good engineering practices. In no event may the initial curative time periods set forth in the interference section of [lie Agreement be more or less than 72 hours. If Licensee doem not cease any interfering operation within such seventy-two (72) hour period, Licensor shall have the right, in addition to any other rights that it may have, to seek to enjoin such interference. d) Termination: Licensor shall have the right to disapprove any proposed installation, modification and/or use of the Licensee's Equipment in the event that any of the permits, authorizations and/or approvals obtained by AirTouch or Licensor from governmental or quasi -governmental agencies for use of any portion of the Tower Site would be adversely affected now or in the future by such installation, modification and/or use, in AirTouch's sole judgement. e) RF Exposure & Testing. Licensee shall be responsible for its compliance with guidelines and procedures for evaluating environmental effects of RF emissions on or from the Tower Site, in strict compliance with FCC OET Bulletin 65, entitled Evaluating Compliance with FCC Guidelines For Human Exposure to Radio frequency Electromagnetic Fields, Edition 97-01, released August 1991 ("OET Bulletin 65"), including the completion of RF worksheets showing compliance with the guidelines set forth in OET Bulletin 65 and all existing and future laws, rules and regulations related thereto (collectively, "EMF Rules"). Licensee agrees to indemnity and hold harmless Licensor and AirTouch in connection with any failure by Licensee to comply with the EMP Rules. At the time of any installation, modification or replacement of equipment by Licensee, Licensee shall notify Licensor prior to any such change or installation and, unless Licensor reasonably determines that such Tower Site is categorically excluded from the requirements of routine or initial environmental evaluations under the EMF Rules, Licensor shall evaluate compliance will! the EMF Rules utilizing the most currently marketed version of the UNIsite, Inc. UNlstar RF power density prediction software ("UNlstar Software"), at Licensee's sole cost and expense based on then -current market rates for the UniStar Software services, together with the cost of RF data collection from other subtenants (if necessary) at Licensor's then -current rate. In the event that any remedial or corrective measures are required as a result of an evaluation associated with Licensee's installation, modification or replacement of equipment, Licensee shall perform such remedial or corrective measure at Licensee's sale expense. f) Environmental: Licensee and Licensor each, respectively, covenant and agree that: (i) it shall not conduct or allow to be conducted upon any Tower Site any business operations or activities, to generate, manufacture, refine, transport, treat, store, handle, dispose of, transfer, produce, or process hazardous substances; provided that Licensee shall have the right to bring and keep at each Tower Site (in compliance with all applicable laws) batteries, generators and associated fuel tanks and other substances commonly used in the industry and necessary for the operation and maintenance of the Licensee's Equipment or the Tower Site; (ii) it shall comply in all material respects with all applicable environmental laws; (iii) it shall not create or permit to be created any Lien against any Tower Site for the costs of any response, removal or remedial action or clean-up of hazardous substances; (iv) it shall, to the extent Licensee or Licensor, respectively, is legally obligated therefor, promptly conduct and complete all investigations, studies, sampling and testing, and all remedial, removal, and other actions necessary to clean up and remove all hazardous substances on, from or affecting each Tower Site in accordance with all applicable environmental laws, in all material respects; and (v) Licensee shall promptly notify AirTouch and Licensor in writing if Licensee receives any notice, letter, citation, order, warning, complaint, injury, claim or demand that: (w) Licensee has violated, or is about to violate, any environmental law, (x) there has been a release or there is a threat of release, of hazardous substances at or from the applicable Tower Site, (y) Licensee may be or is liable, in whole or in part, for the costs of cleaning up, remediating, removing or responding to a release of hazardous substances, or (z) a Tower Site is subject to a lien favor of any governmental entity for any liability, cost or damages under any environmental law. Notwithstanding anything in the Agreement to the contrary, Licensor shall have no obligation to indemnify Licensee for a breach of the foregoing covenants (including with respect to claims for damages or other liabilities due to any necessary g) h) Licensor Site Nanae/Number: Federal Way #2, WA/ 82957 Licensee Site Name/Number: WA-TAC-161-A/Federal Way investigation, remediation or cleanup of hazardous substances at any Tower Site for which Licensor would otherwise have an obligation to indemnify Licensee) unless Licensee first notifies Licensor of such Tower Site contamination or condition and offers Licensor an opportunity to conduct any necessary response or perform any required remediation work and Licensor refuses to do so. Such notice and opportunity to respond shall be given to Licensor in writing prior to any expenditure or commitment by Licensee or any of its Affiliates. Licensor shall reply to the notice and opportunity to respond in writing within forty (40) calendar days of receipt of Licensee's notice, unless Licensee is required to act sooner under applicable environmental laws or by the appropriate governmental authorities. If Licensor elects to respond, Licensor shall perform all work in a workmanlike manner in material compliance with all applicable environmental laws to the satisfaction of the appropriate governmental Authority. Except as required by applicable law, Licensee and its representatives and agents will not initiate any communication or make comments or submissions to any governmental authority or third parties with respect to environmental conditions at any Tower Site to which Licensor has responded. Nothing herein contained shall affect a Party's legal duty to mitigate damages. Subordination: The Agreement and all supplements, amendments, modifications, renewals, replacements and extensions thereof, shall unconditionally be and remain at all times subordinate to all mortgages placed on the Tower Site by AirTouch, and to any replacements, renewals, amendments, modifications, extensions and refinancing thereof, and shall unconditionally be and remain a lien or charge on the Tower Site junior and subordinate to AirTouch's and Licensoe's interest in the Tower Site. Licensee agrees that in the event that the Agreement is assigned to AirTouch, AirTouch shall not: (i) be liable for any damages or other relief attributable to any act or omission of Licensor, or any successor to Licensor (other than AirTouch), under the Agreement; (ii) be liable for any damages or other relief attributable to any latent or patent defects in the construction with respect to the property which is the subject of the Agreement; (iii) be liable for any consequential damages to Licensee attributable to any act or omission of Licensor under the Agreement; (iv) be subject to any offsets or defense not specifically provided for in the Agreement and which Licensee may have against Licensor, or (v) be bound by any prepayment by Licensee of more than one month's installment of rent or for any security deposit not actually delivered to AirTouch. Miscellaneous: i. In no event may Licensee share use of any power meter at any Tower Site with AirTouch. ii. Licensor reserves the right to freely assign the Agreement to AirTouch or any of its Affiliates at any time. iii. Upon expiration or earlier termination of the Agreement or the AirTouch Sublease with respect to the Tower Site, Licensee shall, at its sole cost and expense and upon instructions from Licensor, remove Licensee's Equipment from the Tower Site within a reasonable period of time, but in no event less than thirty (30) days (except as otherwise required by the Ground Lease). iv. Licensee recognizes and agrees that AirTouch is a third party beneficiary under the Agreement with direct rights of enforcement against Licensee of the rights of Licensor hereunder, including, without limitation, the right to cause Licensee to comply with the interference provisions of the Agreement and to enter any of the space licensed by Licensee under the Agreement. v. If Licensee intends to sublease or sublicense available space at the Tower Site, Licensee acknowledges and understands that Licensor must send a copy of Licensee's bona fide offer (containing all of the terms and conditions for such offer to sublease or sublicense, and which must include the specific Tower Site(s) and available space which are the subject of the offer) to AirTouch and that AirTouch may elect, in its sole discretion, to sublease or sublicense such available space from Licensor on the same terms and conditions as Licensee's bona fide offer, or to exercise its right of substitution pursuant to the AirTouch Sublease. AirTouch must notify Licensor in writing of its intent to either sublicense such available space or to exercise its right of substitution with respect to such space within ten (10) business days of receipt of the bona fide offer. vi. If Licensee intends to install Licensee's Equipment (or any subsequent modification) within the area that is ten (10) feet above or below the highest and lowest point of AirTouch's Licensor Site Name/Number: Federal Way #2, WA/ 82957 Licensee Site Name/Number: WA-TAC- 161 -A/Federal Way equipment on the Tower (with full horizontal clearance), Licensee acknowledges and understands that AirTouch shall have a right to approve Licensee's plans and specifications. Licensee shall submit such plans and specifications to AirTouch and Licensor simultaneously and, in addition to any rights of Licensor under the Agreement, AirTouch will have five (5) business days after receipt (or any revisions thereof as hereinafter set forth) to respond to in writing with comments in reasonable detail concerning Licensee's plans and specifications. If AirTouch fails to give such notice of its objections to Licensee's plans and specifications within such period it shall be deemed to have approved such plans and specifications. If Licensee's plans and specifications are not approved by AirTouch, Licensee may revise its plans and specifications to meet the objections thereto set forth in the AirTouch's disapproval. No construction, installation, testing, or operation of Licensee's Equipment shall be permitted unless and until AirTouch approves Licensee's plans and specifications or such approval is deemed granted as set forth above. vii. Licensee shall not create or permit any form of lien to be imposed against any Tower Site or any part thereof. Licensee shall cause any such lien to be discharged by payment, satisfaction or posting of bond within thirty (30) days after the earlier of (i) the date Licensee has obtained knowledge of such lien, or (ii) written notice from Licensor or AirTouch. If Licensee fails to cause any lien to be discharged within the permitted time, Licensor may cause it to be discharged and may pay the amount of such lien in order to do so, which amount and any other costs incurred by Licensor shall be promptly paid to Licensor by Licensee. viii. Any term which is defined in this Rider has been defined herein only for the purposes of this Rider and shall applicable only to this Rider and not to the Agreement. IN WITNESS WHEREOF, the parties have executed this Rider as of theILI day of, 20 LICENSEE: Clearwire, LLC, a Nevada limited liability company By: Name: John Storch Title: VP Network Development LICENSOR: American Tower Delaware Corporation, a Delaware corporation, a wholly owned subsidiary of American Tower Corporation, a Delaware corporation By: Name: Title: C )IJ Licensor Site Name/Number: FEDERAL WAY #2, WA / 82957 Licensor Contract Number: 00182346 Licensee Site Name/Number: Mirror Lake/ WA-TAC161 FIFTH AMENDMENT TO SCHEDULE LICENSE OF SPACE This Fifth Amendment (the "Fifth Amendment") to that certain Schedule License of Space dated May 12, 2006 by and between American Tower Delaware Corporation and Clearwire LLC (the "License"), as amended by that certain First Amendment to Schedule License of Space dated August 5, 2008 (the "First Amendment"), as amended by that certain Second Amendment to Schedule License of Space dated June 30, 2009 (the "Second Amendment"), as amended by that certain Third Amendment to Schedule License of Space dated January 26, 2010 (the "Third Amendment"), as amended by that certain Fourth Amendment to Schedule License of Space dated October 16, 2012 (the "Fourth Amendment") (collectively, the "Agreement") is made and entered into as of the latter signature date hereof, by and between American Tower Delaware Corporation, a Delaware corporation (the "Licensor") and Clear Wireless LLC, a Nevada limited liability company, as successor -in -interest to the Agreement (the "Licensee") (collectively, the "Parties"). RECITALS WHEREAS, Licensor owns a certain communications tower and leases a certain parcel of land located at 30911 Pacific Hwy S, Federal Way, WA 98003-4950 more commonly known to Licensor as the FEDERAL WAY #2, WA tower site (the "Tower Facility"); and WHEREAS, Licensor and Licensee entered into the Agreement for the use of a certain portion of the Tower Facility; and WHEREAS, Licensee desires to modify its equipment at the Tower Facility ("Modified Equipment"); and WHEREAS, the Parties agree that as consideration for Licensee's Modified Equipment, the current License Fee payable under the Agreement shall be increased as set forth herein. NOW THEREFORE, in consideration of the foregoing promises and for other good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, the Parties hereto agree as follows: 1) Licensor and Licensee agree and acknowledge that Licensee shall modify its equipment for a final installed configuration pursuant to Exhibit A-5. 2) Licensor and Licensee agree and acknowledge that Exhibit A-4 to the Agreement is hereby deleted in its entirety as of the date this Fifth Amendment is fully executed and shall be replaced with Exhibit A-5 attached hereto and incorporated by this reference. In the event of inconsistency or discrepancy between the Exhibit A-5 and Licensee's equipment information set forth in the Agreement, the Exhibit A-5 shall control. Licensor Site Name/Number: FEDERAL WAY #2, WA / 82957 Licensor Contract Number: 00182346 Licensee Site Name/Number: Mirror Lake/ WA-TAC161 3) Effective upon the earlier to occur of. i) the issue date of the NTP by Licensor; or ii) 180 days from execution ("Commencement Date"), the License Fee shall be increased by Three Hundred Fifteen and 38/100 Dollars ($315.38) per month ("Increased Fee"). The Increased Fee for any fractional month at the beginning or end of the period shall be appropriately prorated. 4) Notwithstanding anything to the contrary in the Agreement, the offer to Licensee expressed in this Fifth Amendment shall automatically become null and void with no further obligation by either party hereto if a structural analysis of the Tower Facility completed after the execution of this Fifth Amendment by Licensor but before the Commencement Date of the installation of Licensee's Modified Equipment indicates that the Tower Facility is not suitable for Licensee's Modified Equipment unless Licensor and Licensee mutually agree that structural modifications or repairs shall be made to the Tower Facility on mutually agreeable terms. 5) Licensor and Licensee agree and acknowledge that this Fifth Amendment is contingent upon AirTouch Communications, Inc. and/or its Affiliates' Right of First Refusal. 6) Licensor and Licensee agree and acknowledge that all future payments of the License Fee shall be made to the Licensor at the following remittance address: American Tower Corporation Lockbox 7501 PO Box 7247 Philadelphia, PA 19170-7501 7) Capitalized terms contained herein, unless otherwise defined, are intended to have the same meaning and effect as that set forth in the Agreement. 8) All other terms and provisions of the Agreement remain in full force and effect. [SIGNATURES APPEAR ON THE NEXT PAGE] [REMAINDER OF PAGE LEFT BLANK INTENTIONALLY] Licensor Site Name/Number: FEDERAL WAY #2, WA / 82957 Licensor Contract Number: 00182346 Licensee Site Name/Number: Mirror Lake/ WA-TAC161 IN WITNESS WHEREOF, the Parties hereto have set their hands to this Fifth Amendment to that certain Schedule License of Space as of the day and year written below: LICENSOR: LICENSEE: American Tower Delaware Corporation, Clear Wireless LLC, a Nevada limited a Delaware corporation liability company By: Name: Rieha,d-RossMargaret Robin"Name. M"ehelle Fox Senior Counsel Supervisor -Network Deployment Title: ac anage t Title: Date: Date: Licensor Site Name/Number: FEDERAL WAY #2, WA / 82957 Licensor Contract Number: 00182346 Licensee Site Name/Number: Mirror Lake/ WA-TAC161 EXHIBIT A-5 l �wA !Y>•YCRR�I�. Tf)N Y�O.ANd/. wA wA dA wA fYtilNIDNRRAT.nt1G9 WA WA M WA WA '.••�Acn1Y NIA WA wA MIA WA T1h AfN10NI. NANIN9 YGaND WA NIA WA WA WA Yrdl•a WA WA wA WA NIA wA WA WA WA WA INIONFAd q 3.✓e WA dA dA 'Af Ilf� I NIA iiVlC�fYXfWR1Wr✓/MI NUr.p/Sam N/A WA wA WA dA q'.pwrrT]R IW Ad BTN NIN WA @S pNf)Afs .owlt Yll�rY1 ISl IlT IT]' ITI In 1ST TJu. WA ]Jm p1n�fllnLYl TYf! AllNli/ACll�fa iso �� T-M frhs dwK WA TAJI•A�� FriNI>mll 1pifImYNYXtf M0100ff MIOM14 uln]aooB0N0 ]NAVf1W pAalOf wn A2TNHNNf [oi Nn�Tna/>alfllrfvlwW .nlxrn.[ mfxlvA rwfu+ INrNi.+f.r wA A•f.- b.�..Ar..r.t m TwoNTlf•IA,•�1 ]llb >W. Im flb WA on. f431[miN'NRIft / S wA AfpN]m /0L]RNfN�[AENIA'N Ny�S WA O L b1N'fM' WA pTY.6Y.'N S}aONNIm 1OR l.•Ya'f Nln 1N0 Inn IAw � ]tlfi6ASW ]yAiyp[ID. WA N/A ITffl3� AST Spy. S1pp�. Sey]gp NNa NM N/A Wn Ifi3]SI� A 1l�l�.wA�iN.�l Ye Ne WA WA WA Nf ANI�A� 1/ IA.i NIA NIA WA WA Il1TALf i1M[fagyAfi�� NIA WA 1 ItlNOTY,w NA�Aue./m]fi.'Rt�• 1W SOO N/A WA NIA WA WA RIrNb WA WA l IT Y4fNAli1R]� OIiN.w ON,r �--- D'iYmYl pYp�1 Nilwlnld Rb7_Yd RdWW wA NWO]IFT 2fR HT Ilr llT WA r:><sSm/fSWNYNN1afW IV 1TI f9WSdIR Mb'SNf lT7w I'JM NMM fbM IIYM � WA pcNWNTAlYANSeWNs Adw Adn Avbw Ndw NnuN. WA ra��,lrnaf ��a vWn-a Tim v1Ynn[ mem wA plgAfc(]yppfN[SIe11yNfO] pYrM.Mwl l�W N YIySAi• larilfSnlO WA OONTfaI]nNINNTf Ynidl nu. nw flb IxIM1 NIA Wwnfr I I � l wA Afa]tl]]Is.oNlNcrilrlAtAAmYCI.N..0 wYfcr / In bill ISO WA NACIAWYfN]fAZUY. II WVf• I In WA WA S%11110[f>Kf a0]591HSN4 Do139n33®a It,lilfl bl4 f.fiifJfO®a tiµmn adLa115,WY aNlbAllfldf Saw Il.]Af.taa, fAWaAW�. wA .YN�Fr! fA�] No Me Ne Ile Y. WA ANICNAO.W SMI 9.1m HAd� HINIi WA WA WA 1nYAR IY +1aY y�.+.i l Yp pry �YAaf /N lR I� u •VY]' In WA WA WA ypN.lA®]gr 6i lT 1? lw In' WA WA Sprint��'' April 7, 2017 RE: Md7, LLC as representative for Sprint To Whom It May Concern: Md7, LLC and its employees are authorized representatives of Sprint and have been contracted to perform cellular site development (i.e. real estate leasing, land use entitlements, materials procurement, architectural engineering, equipment installation, design, and construction, etc.) on behalf of Sprint, in connection with their telecommunications facility. As an authorized representative of Sprint, Md7, LLC may submit/order (i.e. land use applications and permits, utilities, real estate leasing, etc.) on behalf of Sprint. Sincerely, Kevin Foy (206)-427-5856 Sprint Network Real Estate From: Peter Lawrence Sent: Wednesday, February 17, 2016 10:14 AM To: Permit Center It has come to my attention that there may exist some confusion as to when a building permit is required for the modification of equipment on existing towers. Per my discussion with the Building Official we are not requiring a building permit for modifications to exiting towers ( adding or removing antennas, adding ground equipment cable boxes ) unless they are modifying the footings and stabilization of the tower or they are installing equipment on a building in which case they are adding additional loads to the buildings and we would want a permit for that. I can't speak for the electrical portion of these projects so I do not know if an electrical permit is always required. I hope this clears this matter up.... Peter Lawrence Plans Examiner Federal Way 33325 8tn Avenue South Federal Way, WA 98003-6325 Phone:253/835-2621 Fax: 253/835-2609 www.citvoffederalway.com CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: October 24, 2017 TO: Cole Elliott, Development Services Manager Peter Lawrence, Plans Examiner Rick Perez, City Traffic Engineer Brian Asbury, Lakehaven Water & Sewer District Chris Cahan, South King Fire & Rescue FROM: Jim Harris 253 835 - 2652 FOR DRC MTG. ON: November 2, 2017 FILE NUMBER(s): 17-104972-00-UP RELATED FILE NOS.: None PROJECT NAME: SE52XC364 MIRROR LAKE - SPRINT PROJECT ADDRESS: 30911 PACIFIC HWY S ZONING DISTRICT: BC PROJECT DESCRIPTION: Modify an existing wireless facility to include replacement of antennas, cabinets and cables LAND USE PERMITS: PROJECT CONTACT: JESSICA POMPA MATERIALS SUBMITTED: Preliminary Plans Project Description r �� 1 CITY OF Federal Way APPLICATION NO(S) RECEIVED MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT OCT 16 2017 33325 8`h Avenue South Federal Way, WA 98003-6325 CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609 COMMUNITY DE1/ELOpMENT www.citvoffederalway.com i i o I--7-2-Oc UFi Project Name SE52XC364/ Mirror Lake - 30911 Pacific Hwy S. Property Address/Location 30911 Pacific Hwy. South Federal Way, WA 98003 Parcel Number(s) 0821049024 Date J -01 G 1-7 Project Description Sprint proposes to modify an existing unmanned telecommunication facility. Reference page T-1 of construction PFAN'I Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference _X_ Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information BC Zoning Designation Comprehensive Plan Designation Value of Existing Improvements $50,000.00 Value of Proposed Improvements International Building Code (IBC): U, Unmanned communications Facility Occupancy Type Construction Type Applicant Name: Jessica Pompa on behalf of Sprint Address: 10590 West Ocean Air Drive, Suite 300, City/State: San Diego, CA Zip: 92130 Phone: 858.926.3895 Fax: Email: jpompa@md7.com Signatut Agent (if different than Applicant) Name: Address: City/State: Zip: Phone: Fax: Email: Signature: Owner Name: American Tower Corporation Address: 1101 Perimeter Dr. City/State: Schaumburg, IL Zip: 60173 Phone: Fax: Email: Signature: Bulletin #003 —January 1, 2011 Page 1 of 1 k:\Handouts\Master Land Use Application 4ik CITY Federalo. Way APPLICATION NO(s) Project Name RECEIVED MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT OCT s 2��7 33325 88i Avenue South Federal Way, WA 98003-6325 253-835-2607;Fax 253-835-2609 CITY OF FEDERAL WAY www.citvoffederalway.eom COMMUNITY DEVELOPMENT 1 :7- — 104 9 --7-2 —00 U P1 Date I1DI SE52XC364/ Mirror Lake - 30911 Pacific Hwy S. Property Address/Location 30911 Pacific Hwy. South Federal Way, WA 98003 Parcel Number(s) 0821049024 Project Description PINAW PRINT Sprint proposes to modify an existing unmanned telecommunication facility. Reference page T-1 of construction drawings. Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference X Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information BC Zoning Designation Comprehensive Plan Designation Value of Existing Improvements $50,000.00 Value of Proposed Improvements International Building Code (IBC): U, Unmanned Communications Facility Occupancy Type y Construction Type Applicant Name: Jessica Pompa on behalf of Sprint Address: 10590 West Ocean Air Drive, Suite 300, City/State: San Diego, CA Zip: 92130 Phone: 858.926.3895 Fax: Email: jpompa@md7.com Signatal - Agent (if different than Applicant) Name: Address: City/State: Zip: Phone: Fax: Email: Signature: Owner Name: American Tower Corporation Address: 1101 Perimeter Dr. City/State: Schaumburg, IL Zip: 60173 Phone: Fax: Email: Signature: Bulletin #003 — January 1, 2011 Page 1 of 1 k:\Handouts\lvlaster Land Use Application I ®R Sprint TM 5E52XC3G4 - MIRROR LAKE 3091 1 PACIFIC HWY S FEDERAL WAY, WA 98003 PROJECT DESCRIPTION VICINITY MAP MODIFICATION TO AN (E) UNMANNED TEIPCOMMUNICATION FACILITY CON515TING OF: 1. ROAM (4) (E) ANTENNAS t REWa W7 (3) (H1 TRd-BAN" AHRNNA5 C. . 2. REMOVa` (4) (E) RRU5 t REPLACE NI3) (N) 2WM E RW75 •- 3. IN5TAIi 16) (N) 800 MHz RRU5, t (3) H I900 MHx RR115 - 4. REMOVE (E) CABINET 5. INSTAL (N) ECAWAB MODULAR CABINET W/ (N) GF5 ANTENNA 6. INSTALL (N) PPC t (N) TELCO CABINET ON (N) H-FRAME 7. REMOVE (E) CABLES t INSTALL (4) (N) HYBRID CABLES _`°`An°" PROJECT INFORMATION 51TE NAME: MIRROR LAKE SITE N: 5E52XC364 SITE TYPE: MONOPOLE JURISDICTION: FEDERAL WAY COUNTY: KING COUNTY POWER: PUGET SOUND ENERGY TN o O APN: 0521049024 TELEPHONE: AT4T O SITE ADDRESS: 30911 PACIFIC HWY 5 O FEDERAL WAY, WA 98003 CURRENT ZONING: BC DRIVING DIRECTIONS CONSTRUCTION TYPE: V OCCUPANCY TYPE: U. (UNMANNED COMMUNICATIONS FACIUfY) FROM: 1000 124TH AVENUE NE, BELLEWE, WA 98005 PROPERTY OWNER: AMERICAN TOWER CORPORATION TO: 3091 I PACIFIC HWY 5, FEDERAL WAY, WA 95000 1 101 PERIMETER DR SCHAUMBURG, IL 60173 1. HEAD SOUTH ON 124TH AVE HE TOWARD HE I OTH PL 2. TURN RIGHT AT THE 2ND CRO55 5T ONTO HE 6TH APPUCANT: SPRINT 3, SLIGHT RIGHT ONTO THE IA05 5 RAMP 1000 124TH AVENUE NE, SUITE 201 4, KEEP RIGHT AT THE FORK 4 MERGE ONTO 1-405 5 BELLEVUE, WA 98005 5. MERGE ONTO I-005 5 G. KEEP LEFT TO STAY ON 1-405 5 CONSTRUCTION CONTACT: SPRINT 7. TAKE THE I-5 5 EXIT TOWARD PORTLAND 1000 124TH AVENUE NE, SUITE 201 8. MERGE ONTO 1-5 5 BELLEVUE, WA 98005 9. TAKE EXIT 147 FOR 5 272ND 5T ATM: TONY PINO 10. TURN RIGHT ONTO 5 272ND 5T NEL50N.FINOQ5PNNT.COM 11, TURN LEFT ONTO PACIFIC HWY 5 (415) 7GO-4921 END AT: 3091 1 PACIFIC HWY 5, FEDERAL WAY, WA 98MG LATITUDE: 47° 19' 29.4528- N (47.324845) HAD 83 ESTIMATED TIME: 33 MIN5 E5TIMATED D15TANCE: 25.7 MI LONGITUDE: 122' 18' 52.7148' W (-I22.314643) HAD 83 AM51-: '_4GV 0.1 m 0.7 MI 0.2 MI 0.6 MI 1.6 'MI 11.6 MI 0.3 MI 7.3 MI 0.3 m 0.5 Ki1 2.4 Ml Ulo CODE COMPLIANCE ALL WORK $ MATERTAI5 SHALL BE PWOWED 1 INSTALLED IN ACCORDANCE WITH THE C>JRgENT EDHION5 OF THE FOLLOWING CODES AS ADOPTED BYT'HC LOCAL GOVERNING AUMORMM, NOTHING IN THESE MAN5 6 TO Be CONSTRUEV TO PERMIT WORK NOT CONFORMING TO THESE CODES: I . 2015 INTERNATIONAL BUILDING CODE, 5TANDARD5 4 AMENDMENTS - WAC 5I-50 2, 2015 INTERNATIONAL MECHANICAL CODE, STANDARDS 4 AMENDMENTS - WAC 51-52 3. 2015 INTERNATIONAL FIRE CODE, STANDARDS 4 AMENDMENT5 - WAC 51-54A 4. 2015 UNIFORM PLUMBING CODE, 5TANDARD5 4 AMENDMENTS - WAG 5I-56 5. 2015 WASHINGTON STATE ENERGY CODE, STANDARDS t AMENDMENTS - WAC 5 1 -1I C G. LOCAL BUILDING CODES 7. CITY/COUMYORDINANCFS 8. AN5VEIA-TIA-222-G ALONG WTTH ANY OTHER APPLICABLE LOCAL t STATE LAN5 AND REGULATIONS ACCE551BILITY REQUIREMENTS TH15 FACILITY 15 UNMANNED 4 NOT FOR HUMAN HABITATION. ACCE551BILTTY REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2015 IBC BUILDING CODE SHEET INDEX T- I TITLE 5ffET - A- I 51TE PLAN - A-2 EQUIPMENT PLANS - A-3 ANTENNA PAAN5 - A-4 ELEVATION5 - A-5 DETAII5 - A-G DETAILS - E- I GROUNDING DETAILS - RECEIVED OCT 16 2017 COMMUNOfFTYFEDERAL OP ENT APPROVAL LF LEA5ING ZONING CONSTRUCTION 5PRI NT PUGET 50UND ENERGY CIL 8 m �o m am oa a" 0 z !Wei C� E¢ U) Li W a 3gs pp Zlift �.� m m 81! W IL Q �RwK� MIRROR LAKE 5E52XC3G4 30911 PACIFIC HWY5 FEDERAL WAY, WA 98003 155UE STATUS ❑ DATE DESCRIPTION 09/22l17 CD9096 DRAWN BY: R. MARTINEZ CHECKED BY: T. D,CARLO APPROVED BY: a MCCOMB DATE: 09/27/17 SHEET TITLE: TITLE 51-IEET 5HEiT NUMBER T- I PROJECT GENERAL NOTES I . TH15 FACILITY 15 AN UNOCCUPIED WIRELF55 TELECOMMUNICATION FACILTI'. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY UNLE55 NOTED OTHERWISE. 3. THE SCOPE OF WORK SHALL INCLUDE FURNISHING MATERIALS. EQUIPMENT, APPUKTENANCE5 AND LABOR NECE55APYTO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. PRIOR TO THE WDS4551ION OF ENDS, THE CONTRACTORS SHALL V15LT THE JOB SITE AND BE FZSPOF ftE FOR ALL CONTRACT DOCUMENTS, F1EL0 W!lOTAOLFSFHU O1FA�1510F75. AItU CONFLRM TLIATIHE WYhC& MAY BE ACCOMM151710 A5 5110" PRIOR TO PROCCEDRiG WITH COmg%)CNON, ANYDL5CREPAHM ARE TO BE BROUGHT TO THE AT MWMM Of THE CONSTRUCT ON MANAGER AND ENGIFIEER ?I" TO PROCEEDING WITH THE WORK. 5. IT 15 THE RE5PON5151UTY OF THE CONTPJLS.TOR TO PAY PCP PERMIT FEES AND TO OBTAIN SAID PERM AND TO CDORQ MTE INSPECTIONS. G. THE C(LINTTZ L70R 5HALL RECEIVE, IN WRIFING, AUTHORIZATION TO PRQCEED BEFORE STARTING WORK ON ANY ITEM NOT C.EARLYMMMED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 7. CALL BEFORE YOU DIG. CONTRACTOR 15 REQUIRED TO CALL 81 1 (NATIONWIDE 'Gkjbff.(RE YOU DIG HOTUNE) AT LEAST 72 HOUR5 BEFORE DIGGING. 8. ALL WORKPIE!".1" AND MATERIAL5INSTALLED 5HALL BE IN STRICT ACCORDANCEWMiALL APPUCAHLE CODE5,RiGU1AT10N5.AND ORDINANCES, CONTRACTOR 5NALL GIVE ALL NDTiCE5 AND COMPLY Witt AIL lAW5.O HANCE5. MIES. ROGMT06 AND L MML ORDERS Of ANY PUBUC AUNfDRRY REGAP.AING THE PERFORMANCE OF THE WORK. 9. THE GENERAL COWKACTOR5HALL SUPFRVT5E AND DIRECT THT WOU 05 W THE BEST 5NO AND ATN:?LTLON. THE CONTRACTOR SHALL DE 50ME ,PJff2V6W PORALL CQ16TR17CDON MEANS. Kn=5, TMH;NIQUL5, 5EQLIENCF5 AND PROCIEDLI 5. CONTRACTOR SHALL AL50 COOKIDIAACE ALL FORII06 OF THE WORK LAM THE CONTRACT; RNGUIOIHG CONTACT AND COORDINAWN WITNTHE D0115TW1CF10" MANAGO{ AND WFNN THC LANDLOM AUTHCfi= REITJ5 NTATIVE• 10. THE CONTKAI:TO SHALL MAI(E NECE55W PRTN151QN15 TO PROTECT OItS' rra IMPRIOrQAIN15, PAVING, CURBS, GALVANIZED SURFACES, ETC.. AND "COA LETION nP OW REPAIR ANY U"Ma THAT OCCURRED DURING CON5TRJCTiDN TO THE SATrSPACADN OF Tm PROJECT MANAGER. 1 1. KEEP GENERAL. AREA WAN, HAZARD FREE, AND 05F= OF ALL DIRT, DUW,5, RUBBISH AND REMDVE EA"AIU'MW NOT 517MMED AS REMAINING DN1 TTE PROPERLY, LEAVE L'RENAl5E91N am LDD1ao[fIOH AND FRCS FROM PANT 5POT5. MT. OR SMUDGE5 OF ANY NATURE. 12. ALL BASTING INACTIVE SEYIF.R WATER, GAS. ELECTRIC, AND OTHM UTILITIES, WUCH IMM M W "THE fD MON of Rif WM SHALL BE RDAOVEO A)MR CAPPED, PL.UGGED.OR OFHERWT51! DISCONNECTED AT POEMS WHICH WLLL NOT MHUM WNH THE mamoN OF THE wom AS DIRECTED yr THC RF5PON ai 04GI11M AND 50JWT TO THE APPROVAL OP THE OWNERAMMA LOCAL UTILITIES. 13. ALL ETgSTING ACTIVE 5Vh%P, WATEIC GAS, ELECTRIC ANA ALL OTHER UTIUTIE5 WHERE V COUNTEM N THE WORK SHALL BE PROTEM AT ALL TIMES. 14. DETAIL5 ARE INTENDED TO 5HD'W END RESULT OF DESIGN. MINOR M9WPTCATIONLS MAYBE REQUIRED TO 5Uri JOB 01WD610009 CONDMONL5, AND 5UCH MWNCATLUN9 SHALL BE INCLUDED A5 PART OF THE WORM, 15. CONTRACTOR SHALL PROVIDE A TOILET FACILITY DURING All PHASES OF CONSTRUCTION. 16.5VMC04 MGINIIADUATION WAS Mg WOVEPED TO E5TA&*H THE PC61T1OI1 OF THE BOWOM WES SHOWN HEREON. THE OWIDARY ON THIS MAp 15 BASIYI ON COMPILED RECORD DATA AND Bw FIT ONTO D05 m IMPROVEMENTS. IT r5 POSSIBLE MR THE LOCATION OF THE STIBICCT PROPERTY TO 5HLFT FWM THE RACEMENT Va" HEREON WITH ADDITIONAL MD WORK AND Rf5T7=. "MM ANY SPATIAL RPPERfla MADE OR 5'LDWN BETWEEN THB PELAMI5HIF OF THE BOUNDARY LINES 5mmi HiPEOFI AND MTIN♦G GROUND FEATUKC5, EA5EMft S OR LUSE AREA 15IWWIDCD TO Be ApP;o C.WATE AND 15 SUEUEGT TO VE UW ATEN BY KSOLVNIG THE POSITION OF THE BOUNDARY UNE5. 17. CONTRACTOR TO VFPIFYTHE LATEST/CURRENT P.F DESIGN. (E) BUILDING (E) BUILDING (E) BUILDING (E) 51TE ACCE55 ROUTE (E) DOUBLE ACCESS GATE (E) CHAIN LINK FENCE W/ BARBED WIRE (E) BUILDING (E) GENERATOR ON (E) CONCRETE SLAB 0 (r7 GRASSY UST (E) PROPERTY LINE (E) PARKING EOT APN: 0821049024 SEE EQUIPMENT ANTENNA PLANS (E) EQUIPMENT COMPOUND W/ (E)1(N) SPRINT EQUIPMENT (E) MONOPOLE W/ (1M SPRINT ANTENNAS (E) EQUIPMENT SHELTER BY OTHERS (E)PROPERTYUNE TN 51TE PLAN 1'=20 0 ra 20 40 w I (E) BUILDING I ;y' (E) FARK114G LOx I I 8 0 2 LU E n L3 U 6 z i IL 111 MIRROR LAKE 5E52XC3G4 30911 PACIFIC HWY5 FEDERAL WAY, WA 95003 155UE STATUS Z� DATE I DESCR MON 09/27JI7 LD9D% DRAWN BY: R MARTINIS CHECKED BY: T. DiCARLO APPROVED BY: B. McCOMB DATE: 09/27/17 SHEET TNIC: 51TE PLAN A®! (E) EQUIPMENT BY OTHERS. TYP OF (4) (E) MONOPOLE — (E) CONCRETE SLAB (N) WORK LIGHT (N) SPRINTTELCO CABINET (E) ICE BRIDGE BY OTHERS / PPC ON (N) H-FRAME (N) 7 X 9'-G' SPRINT LEASE AREA (4) (N) SPRINT HYBRID CABLES. ± 150 (N) SPRINT ECAE/BCAB MODULAR CABINET (E) SPUCE BOX ON (E) H-FRAME (N) SPRINT GP5 ANTENNA (E) SPRINT ANCILLARY CABINET TO BE REMOVED 4 REPLACED (E) METER ON (E) H-FRAME TN TN EXISTING EQUIPMENT PLAN 1 /2'=1'-0' CFC CHAPTER 6 COMPLIANCE TOTAL ELECTROLYTE =12 BATTERIES X 2.49 GAL / BATTERY = 29.88 GAL (SINCE <50 GAL OF ELECTROLYTE, CFC CHAPTER 6, SECTION 605 NOT APPLICABLE BATTERY INFORMATION (BATTERY ELECTROLYTE DATA - 12V MONOBLOCKS) TOTAL! OF TOTAL ELECTROLYTE TOTAL ELECTROLYTE %5ULFURIC ACID VOLUME/ UNIT BATTERY MODEL BATTERY UNIT5 VOLUME (GAL) PER WEIGHT (L65) PER _ ACID BY VOL ELECTROLYTE VOLUME / UNIT INSTALLED UNIT UNIT 12NDT 150 12 2-49 GAL 27.25 LB5 58% = 1.45 GAL / 2.49 GAL % SULFURIC TOTAL ACID WEIGHT TOTAL UNITS X TOTALSULFURIC a SULFURIC TOTAL 5ULIi1R1C TOTAL UNITS X ' ACID BY WEIGHT = TOTAL ELECTROLYTE VOLUME (GAL) WEIGHT (LB5) ACID WEIGHT / UNIT WEIGHT VOLUME / UNITS 12 UNITS XS 40.8% = I I.12 lB5 / 27.25 LB 17.4 GAL = 1.45 / UNIT 133.44 LBS = 12 UNff5 X I I.I 2 IBS BATTERY DATA CHART NEW EQUIPMENT PLAN 1/2'=1'-0' V g m - U) o 0 m N O IZ x� r4 V E IS c U a z E 4A z I"$ gIng O� B rc FW X� .0 °•rn ri MIRROR LAKE 5E52XG364 30911 PACIFIC HWY 5 FEDERAL WAY, WA 98003 155UE STATUS ❑ DATE DEE5CRIPNON 09/22/17 050% DRAWN BY: R MARTINEZ CHECKM BY: T. DICARLO APPROVED BY: B. McCOMB DATE: 09/27/17 9.'M TMf: EQUIPMENT PLANS SHEET NUMBER A-2 (E) 5PRINT ANTENNA TO BE REMOVED f REPLACED, (2) PER 5ECTOR A. E (1) PER 5ECTOR5 B t C. (4) TOTAL (E) 5PRINT RRU TO BE REMOVED 0 REPLACED, (2) PER 5ECTOR A, /(1) PER 5ECTOR5 B 4 C, (4) TOTAL "k. �;10�G A 6� ED� (E) MONOPOLE (E) MICROWAVE DI511, TYP Of (4) Ml n 1(� �TOR8 (N) 5PRINT 800 MHz RRH, PER 5ECTOR. (6) 701 (N) 5PRINT 2500 MHz RRH, PER 50CM (3) TOI TN TN EXISTING ANTENNA PLAN 1/2'= 1'L ANTENNA AND TRAN5MI5510N CABLE5 5CHEDULE (VERIFY WTIh CURRENT EBT5) ANIE(NA A2IMINN TRMW 59DN LINE PROPOSED RAD 1545NNG PROPOSED IENGH 3UA4Et TIPE(5) CONVEYANCE ANTENNA TECHNOLOGY ANTENNA MODEL fJtrAfR 80(A19004500MHz ETLR£5412116 0' P 144'-V 2150 51-0' + 8ow4 RG,5ORSEALT"w 1 EIM190q'2500 M1h ETCR-G54LI2N6 HOP TOY 144.0 t150 Y-O, +FIBERG FIGS OR5EALTrrE FLEX j3 I 8=190025ODMt4 ETCR554L12H6 2P 280, 144'-0' t150 51-0' FIBER 66 Haw4 FIGS OR 5FALTITE FLEX - GPS LI GPSIMG+HR-26N - - - NOIE5. I . 15051ING ANMMI 5 ARE CDMA URP55 NOTED ODIERM5E 2 DIMEN5I0115 OFD05TINGANUN055PA13NGOREATFORM5 ARE AFTEMMATE LONTRAQOR5HAll REIDVERifY RIORTOSTARTOFCOIISTRUCTION 3 PROPOSED5PRINFANIENN45INONDEFMPECNVERRD5WNICH5HALLBEMDUNTEDONTHERPEBEIINDTHEANTENNA5IMIIARTOTHAT5H0'MIINRRUMOUNNNGDETAIL5. 4 RED VERIFY Ea5TING A11MUB1 BEFORE SLIDING THE ANTENNA PRIORAPPROVAL FROM SFRINT MU5T BE OBTAINED BEFORE MOVING ANYM!"ENNA5. 5 APFRO)aMATE LENGTH of (1) ANIETm CABLE RUN a APPROY LENGTH OF LATERAL DISTANCE+ MMM4 MOUNTING HEIGHT+ 20 G. COMRACTOR 9tALL VERIFY TM DOMRILT OF EACH ANTENNA WIM A DIGRAL LEVEL 7. CONIRAGTORTO CONFIRM ANTENNA CABLE COLOR CODNG MDR TO CON5IRUCIMN.(5EE 51EET RF-2) B COLOR BNIDING SHALL BE 2- WIDE ON THE MAIN UNE(5 WRAP MIN.)5PACNG TO BE I -BETWEEN COLOR5, COLOR BAND ON NMFER5 I -WIDE WTTH I'SPACE START COLOR BAND52' BEYOND WEATHHPROOFING START SECTOR COLOR KW TO END CONNECTOR 5M SHEET RF-2 FOR HYBRID ANITHNA CABLE MDR CODING. 9- COAX JUMPTR55t1ALL NOT E(CEED 15111 TERM;CONFIRM 5PECFIC LENGTH PER 511E MM CURRENT IBIS 5PRINT 1900 MHz RRH, (1) R SECTOR, (3) TOTAL 1RAuw )� QR SPRINT TRWMW ANTENNA µ7 H MOUNTING PIPE, (1) PER 5ECTOR, (3) TOTAL NEW ANTENNA PLAN IrrAuff•J (E) ANT (E) MICI (E) 5PRINT ANSENNA REPLACED. (2) P PER 5ECTOF (E) 5PRINT W9.1 REPLACED.J2) P PER 5ECTOf EXISTING SOUTH ELEVATION I /8'= I'-u TOP Of MONOPOLE t RAD CENTER OF (E) ANTfM P3 BY OTHERS TIP Of 0 5PRINT ANTENNAS, x 14Y-9' v s RAD CENTER Of Tea t (N) 5P6)lff Ah'"NA5 GRANNDIEvEI OF (NJ 5PPJNT ANTENNA5 (N) SPRINT PPG CABINET ON (N) 1 (N) SPRINT EC MODULAR NEW SOUTH ELEVATION A- Ln g m V= '= o m a� �w m 0 m 0 {� LYE■ �G]} Z E J., I�,��� y oR U) W 20 • lipI µ MIRROR LAKE 5E52XC364 30911 PACIHChWY5 FEDERAL WAY. WA 98003 155UE STATUS DATE DE5MMON 0A22w CD 9036 DRAWN BY: R. MARTINEZ CHECKED BY: T. DiCHRLO APPROVED BY: B. McCOMB DATE: 09/27/17 5HEET TME: ELEVATION5 RUMOER A-4 7( KMW ETCK G54L 12HG WIND AREA: 12.38 50 PT WEIGHT: 99 LE5 W1 MOUNT CLAMP5 DIMENSIONS: 84.9'TALLX21.O'WIDEX6.3'DEEP SAMSUNG RRH-V3 RF CONNECTOR5: (8) 7-16 DIN FEMALE. (8) MINI DIN .�= 21.a TOTAL WEIGHT: 59.5 LB5 (71.62 L55 W BRACKET) DIMENSIONS: 15.03' X 21.26' X 8.03' LED INDICATORS TOP VIEW RETCONNECTOR— AMPHENOLFIM MPO CONNECTOR 6.3' IS Q3 51NGLE CONNECTOR FOR 6 RBER5 DC POWER — CONNECTOR (8) RF OUTPUT 8m, PORTS MINI DIN RFCAUBRARON -- PORT- N TYPE TOP VIEW PORT LAYOUT 84.9' RRH-V3 21.26' FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW ANTENNA DETAIL RRH-V3 DETAIL 3o.a� TOP VIEW FRONT VIEW ECAB CABINET TOTALWEIGHT: 505 LB5 DIMENSIONS: 30' X 38' X 73.5' E-CABINET 7 36.0' E c;InF \/IFIA/ ECAB CABINET f 16.54' f ECAB CABINET D m TOTAL WEIGHT: 330 L65 VOUT BATTERIES !D m DIMEN51ON5: 16.54' X 34.72' X 70.00' TOP VIEW 15CAB CABINET FRONT VIEW SIDE VIEW ECAB CABINET 3 5AM5UNG 800 MHz RRU WEIGHT: ± 55 LB5 DIMEN51ON5: 23.G' TALL XI5.T WIDE X 6.7' DEEP CONNECTOR: 7-16 DIN 6.7' PROTECTIVE 5HIELDING (OPNONAQ TOP VIEW 5AM5UNG80oMHzRRu FpnKIT VIFIA/ rinF vlFu/ 3 800 MHz RRU DETAIL ---- TELCO CABINET TOTAL WEIGHT: 50 L35 DIMENSIONS: 24.0'X 36.O' X 23.0' �24.a TOP VIEW FRONT VIEW TELCO CABINET, ELTEK PM 3922004700 23.0' %' PLYWOOD BACKBOARD I OR EOUIV I I I I 1 1 PIr-HT VIFW TELCO BOX DETAIL 1- 9.0' �{ TOP VIEW 5AM5UNG 1900 MHz RRU 23.8' FRONT VIEW SIDE VIEW � 1900 MHz RRU DETAIL A PP!' ('ARIAIFT TOTAL WEIGHT: 80 L35 DIMEN51ON5: 24.00 X 36.a X I O.a 24.a TOP VIEW PPC CABINET, ELTEK PM 581 1 12203G I o.a ❑ I 36.a L FRONT VIEW RIGHT VIEW PPC DETAIL 8 112'a I� PCTEL GP5-TMG-HK 2GN DIME14510N5: 5.0' TALL X3.2' WIDE WEIGHT: 0.6 U35 CONNECTOR: IN, FEMALE (ONE - BOTTOM FED) MOUNTING: PTT PIPES 1' - 1.45' FREQUENCY BAND: 1575.42 +/- I.2MHz 5L-3. GP5-TMG-HP, 2GN GPS TMG-MNT-K GP5-TMG-HK-2GNCM (.� GP5 ANTENNA DETAIL MAX ... ....7-IFl�'- 6' MIN EDGE D15TANCE H-FRAME DETAIL 5 Irz•=1' CAP GALV UNISTRUT P 10(XT TYP 3' STD GALV P05T 5EE BASE PLATE DETAIL ANTENNA MOUNTING DETAIL I' (4) 0 its - MOUNTING HOLES "OUNTING FIARDWARE ARIE5) MOUNT PIPE PANEL ANTENNA (VARIES) — MOUNTING PLATE VARIES PER rABINET 150 VIEW 51DE VIEW RRU POLE MOUNTING DETAIL 3' STD GALV P05T 3' STD GALV POST UNISTRUT PIPE STRAP 8' MIN sLAO mICKNEss +' W2' S.S. HILTI KB-TZ — 800/2' GALV A.3G STEEL e W/ 3V4' EFF EMBED BASE PLATE DETAIL_ I'=3' GALV UN15TRUT PIOODTTYP 51DE VIEW CABINET MOUNTING DETAIL NMI EQUIPMENT CABINET EQUIPMENT CABINET 0,VZ A325 GALV BOLT, NUT # WASHER 2' LIQUID TIGHT STRAIGHT CONNECT, CARLON CAT # LT43J OR 2' SEAL TT'. 90' CONDUIT CONNECTOR PART# 500007 OR EQUAL 2' LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT (LNFC) I' HYBRID CABLE, INSTALL IN FINAL PERMANENT PO5MON CABINET A¢' 55 HILTI KB-12 W/ 01 %' WASHER, 2' MIN EFFECTIVE EMBED INSTALLED PER MFR SPECS (]CC E5R-19I7). TYP O1`4 CONCRETE SLAB MIN 5LAD THUM55 CABINET ANCHORING DETAIL JIVL VILVV �Q LE ENTRY DETAIL GROUNDING NOTES I . ALL DETAILS ARE 5HOWN IN GENERAL TERM5. ACTUAL GROUNDING I1,15TALLATION AND CON5TPAILWN MAY VARY DUE TO 51TE SPECIFIC CONDITIONS. 2. GROUND ALL ANWINA BASF5, FRAME5, CABLE RIM- AD OTHER'AUALUC M&'ONENIS U51NG e2 GROUND W195 AND CONNEM TO SURFACE MOUNTED GROU IV BU5 BARS A5 5}ypFR{. FOLLOW ANTENNA AND B75 MWUPACR PRACIICFS MR GROUNDIIr- REQUIREMENTS. GROUND OW SIRED AT BOTH Do U5%MANUFACTUM PP.AGTCi9, ALL UNDERGROUND WATER MM. hTTALCONDUTS AND GRWND5 reAT ARE A PART OPTH15 5Y5TEM 5HALL BE BONDED TOGETHER 3. ALL GROUND CONNECTON5 5HALL BE 12 AWG U.N-0. ALL WIRE5 SHALL BE COPPER THHNATHWN. ALL GROUND WIRE 5HALL BE 5OUDTIN MATED OR 5TRANDED GREEN IN5ULATED WIRE. 4. CONFIWCTORTo VERIFY ANDTE5T GROUND TO 50URCE. 5 OM& MAXIMUM, PROVIDE 5UPPLEMENT GROUNDING RD05 A5 RVMXt DTO ACHIM 5WRED 0HM5 FVD',NG. GROUNUING AND OTHER OPTIONAL T15TING WILL 156 WrME55F-D $YTHE CLEARWIRE REPRESENTATIVE. 5. NOTIFY ARCHTECT/ENGINEERIfTHEREAREANYDIFRCULTIE51N5TAWNGGROUNDING5Y5TEM DUE TO 51TE SOIL CONDMON5. G. BARE GROUNDING CONDUCTOR 5HALL BE HARD DRAWN TINNED COPPER 505 A5 NOTED ON PLAN. 7. ALL HOPJTONTAilY RUN GROUNDING CONDUCTOR5 5HALL BE I1,15TALLED MINIMUM 30' BELOW GRADbFR()5T-LINE IN TRENCH, U.N.O., AND BACK FILL 5HALL BE COMPACTED A5 REQUIRED BY ARCHITECT. 8. ALL GROUND CONOULTOR5 5HALL BE RIM A5 5TRAHGNT AND 5110RT A5 P0551BLE, WITH A MINIMUM 12' BENOING RADIU5 NOTLE55TILIN 90 VfGRR5- 9. ALL SUPPORT 57RUCR=, CABLE CHANNEL WAY5 OR WIRE GUIDES 5HALL BE BONDED TO GIB 5Y5TFM AT A POW NEAREST THE WIN GROUNDING BUS %W (OR DIRECTLY TO GROUND -RING). 10. ACCEPTABLE CONNECTON5 FOR 6ROUNDINGSY5TEM 5HALL BE: a. BURNDY, THY -GRADE U.L USIM CONNECTCA5 FOR INDOOR U5E OR A5 APPROVED BY CLFAWKE PROJECI MANAGER- b. GgWnD. EXOTHERMIC N'EDB TVALLDED OONNECTON5). c TWO 42) HOLETINNw CLIFPERCOMMMION (LONG BARREL) FTTING5 (BU5 BAR CONNECT(ON5). 11. ALL CRIMPED CONNECTON5 5HALLHAVE EM5055FD NWLWACTIIREK5 DIEMARK V151BLE AT THE CRIMP (RESULTING FROM U5E OF PROPOCCRIMPING OCVM)- H 2. PRIOR TO ANY UXrBIF513ARCONNECTON5, THE BU° R5MQ BE CLEANED BY U5E OF "SpOTCH BRTP OR PLAIN 51L7J. W=AS TO REM=ALL SURFACE MDATON AND CONfAfdiNWT5, A COATING OF 4N a -ID° SHNfi BE APPLKO To THE CONNECTION 5URFACE5. 13. ALL CONNECTION HARDWARE 5HALL BE TYPE 316 55 (NOT ATTRACTED TO MAGNET5). 14. THE GROUND RING 5HALL BE I1,15TALLFD 24, MINIMUM BEYOND ANY BUILDING DRIP LINE. 15, €LWMCW.5ER a EQUIPMENT GRQLIifn SHALL OOMPLYWITH NEC. AK"= 250-82 AND SHALL BOW ALL t1 %W AND NEW GROUNDING QECTROa. NEW GROUNDING FLECTPY,DDE 51 ALLIR=VE BUT NOT LIMITED TO GROUND RW5, GROUND PANG IF SERVC 15 WITHIN THE RADIO EQUIPMENT LOCATION. BUILDING STEEL IF APPLICABLE. COLD WATER CMtCTIONS M05T BE MADE ON THE STREET 51M OF MAIN 5tW-XF VALV[. GROUND BAR A2 AWG FROM EQUIPMENT TO BE GROUNDED N (Q PC4E 5ERVICE NEMA 3R, 200A, 240/120V, 10, 3W, 14kAIC METERMIAIN, PAN ELBOARD SERVICE ENTRANCE RATED VOLT5: 249120V. 10, 3W 51,15 AMPS: 200A 5C LEVEL: I OkmC MAIN CB: 200A LOAD DF5CRIPTION BKR AMP/ POLE I CIRCUIT NO 6KR AMP/ POLE LOAD DE5CRIPTION ECAB 100/2 •, 01 03 02 04 20/ 1 20/1 LIGHT5 _ PLUG BLAB IS/2 OS 06 SPACE 07 OB SPACE SPACE 09 10 5PACE SPACE I IL 12 5PAr_E G17D PPC I 240/12OV, 200A, 10. 3W, I OkAIC G N n 2CL7A 100A L �i � —2p I�] GkID i DUAL CADWELD5, TO BE U5ED W/M 2 AWG BOO SILICON SEAL TO GROUND RING AT TOP I' OVC 5EALTITE NOTE: 1. COUMCTORTO UTUZE KOPR-5HIELD (THAN5 t BETT5) ON ALL LUG CONNECTION5 OR APPROVED EQUAL 2. ALL LUGS TO BE DUAL HOLE LONG BARREL AND CRIMPED TWICE WITH MPR5 RECOMMENDED TOOL GROUNDING BAR CONNECTION DETAIL 3 � NT5 15A 20A r, 2OA 2P ., IF IF (E) UGHT (E) PLUG SCAB BCAB 51NGLE LINE DIAGRAM � SINGLE LINE /PANEL DIAGRAM (N)100 AMP BREAKER (N)15 AMP BREAKER DOWNTILT BRACKET MOUNT PIPE (N) PANEL ANTENNA PER PLAN NOTE: MOUNTING CONFIGURATION5 VARY FROM SITE TO SITE, CONFIRM 5PECIFC MOUNTING CONFIGURATION W/ ANTENNA LAYOUF5. (N) RRH PER PLAN (N) N6 AWG RRH GROUND CONDUCTOR 82 AWG MAST GROUND CONDUCTOR 1 _ 4 (E) COPPER GROUND BU5 BAR (N)Y2' COAX JUMPER l TO GROUND I (Q HYBRID ANTENNA CABLE ROUTED TO MATCH (E) AND/OR UNDERGROUND CONDUIT PATH TO MME5 CABINET MUDROOM ANTENNA/RRH CABLE ROUTING I1,15TALL MOUNTING PIPE ITT) YA LAICAL GFND EXOTHERMIC CONNECTION INSTALLANIENNA(TYP) ^+ "' � MECHANICALCONh'ECT70N IN5TALL RRH (") JUMPER CABLES (") FIBER t DC CABLES aYP) BREAK OUT CYUNDER5 T(P) (N) EQUIPMENT CABINET5 SECTOR GROUND BARS (TYP) UPPER GROUND BAR GP5 UNIT 01Ya' 5CH 40 5TAINLE55 STEEL OR GALV PIPE UN15TRUT P I OOOFx LENGTH A5 REQ, 2 MIN IYq' PIPE TOP 1010 SPRING NUF, TYP BURNDY TYPE GAR GP5 MA5T GROUND WG 62 AWG TO GROUND M2 AWG TO GROUND GP5 COPPER GROUND BAR #2 AWG GROUND WIRE EQUIPMENT GROUND GROUNDING DIAGRAM MINIMUM OF 75% OR 270' IN ANY DIRECTION GP5 'v N 5ECURETO5HEETMETAL GP5 OB5TRUCTION5MU5T LNCLO5URE L151NG: 0Y' SHEET BE BELOW 15' METAL 5CRM (2 PER UNI5TRUT) z z N6AVYGCABLE MINIMUM SKY VIEW REQUIREMENT5 GROUNDING W OV COAXIAL CABLE GP5 ANTENNA GROUNDING � SPECIFICATIONS NOTE5: I THE GP5 ANTENNA MOUNT 15 DE51GHED TO FASTEN TO A STANDARD I- 1/4' DIAMETER 5CHEDULE 40. GALVANIZED STEEL OR STANLF5.5 5TEEL PIPE. THE PIPE MUST NOT BE THREADED AT THE ANTENNA MOUNT END. THE PIPE 5I11ALL BE CUF TO THE REQUIRED LENGTH (MINIMUM OF 18 INCHE5) L 51MG A HAND OR ROTARY PIPE CUTTER TO A55URE A SMOOTH AND PERPENDICULAR CUT, A HACK 5AW 5HALL NOT BE USED. THE CUT PIPE END SHALL RED BE DE-BARAND SMODTFI IN ORDER TO SEAL AGPJNST THE NEOPRENE GA5KET ATTACHED TO THE ANTENNA MOUNF, 2. IT 15 CRITICAL THAT THE GP5 ANTENNA 15 MOUNTW 5UCH THAT IT 15 WITHIN 2 DEGREE5 OF VERTICAL AND THE BA5E OF THE ANTENNA 15 WITHIN 2 DEGREE5 OF LEVEL 3. DO NOT 5WEEP TE5T GP5 ANTENNA 4. IT 15 CRITICAL THAT THE GP5 ANTENNA 15 MOUNTED 5UCH THAT MIN. 5KY VIEW REQUIREMENT5 ARE MET, (SEE ABOVE). ®C LA g �o m om � U a o� N 0 �s �� E Is p ++ in LLI ZCl i < aR� o� m N ¢ Et€ ILI a �a B �d�%4vnLL MIRROR LAKE 5E52XC3G4 30911 PACIFIC HWY5 FEDERAL WAY, WA 98003 155UE STATUS Z� DATE I DE5CRIFTION 09/22/17 CD 90% DRAWN BY: R MARTINEZ CHECKED BY: T. DiCARLO APPROVED BY: B. McCOMB DATE: OEV27/ 17 5HEET TITLE: GROUNDING DETAILS 5-11m Nlkl82R E- I