Loading...
16-101961CITY OF Federal Way EMER-03=0 RE- Permit #16-101961-00-A1; GORSKI 30040 12th Avenue SW, Federal Way L UTY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www. cityoffederalway, cam Jim Ferrell, Mayor On April 22, 2016, the City of Federal Way's Department of Community Development received your request for a critical areas letter regarding, the above -mentioned property, parcel #515320- 048 1. City critical area maps do not show any critical areas on or in proximity to your property. If you have any further questions, please feel free to contact me at david.lee@cityoffederalway.com, or 253-835-2622. OEM David Lee Planning Intern Doc. I D. 7_3281 pgCOVED REQUEST FOR ADMINISTRATIvE DECISION DEPARTMENT OF CommuNiTy DEVELOPMENT CaFY OF APR 2 2 2016 33325 8h Avenue South Federal Way Federal Way, WA 98003-6325 CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609 CDS 21KINI-6 k10 Fred —cra I kva \. Co In /FILE NUMBER (0 0 1+b Date—H0.?, Applicant HAIM PRIMARY PHONE Brian Gorski (206) 930-5306 BUSUMSIORGANMATION ALTERNATE PHONE Home owner (206L592-6175 MAMIND ADDRESS E-MAIL 30040 12th ave SW brian98991 P_qmail.com OUT STATE ZIP FAX Federal Way WA 98023 Property Address/Location 30040 12th ave SW Federal Way, WA 98023 Description of Reques; El Code Interpretation/Clarification El Critical Areas Letter/Analysis/Peer Review El Request for Extension (Land Use/Plat Approval) El Revisions to Approved Pen -nit El Tree Removal Zoning Compliance Letter - No Fee - No Fee (Actual Cost if Applicable) - Check Current Fee Schedule - Check Current Fee Schedule - No Fee - Check Current Fee Schedule Bulletin #079 — January 4, 2016 D..i 7i.n CD O O W.T. 1500 GALLON PUMP TANK WITH ❑SI PF2005 1/2 HP TURBINE EFFLUENT PUMP SET TO DOSE SEWAGE TANKS TO BE INSTALLED 47.5 GALLONS ONCE EVERY TWO HOURS VIA AND BEDDED ACCORDING TO THE DRAINFIELD TO BE COVERED WITH 6' OF CONTROL BY THE RHOMBUS IFS (OR EQUIV> MANUFACTURER'S DIRECTIONS AND SANDY LOAM COVER SOIL AFTER FINAL TIMER CONTROL PANEL UPON A LEVEL, STABLE BASE THAT INSTALLATION INSPECTION. DESIGNER TO WILL NOT SETTLE, TANKS TO BE WATER TIGHT VERIFY QUALITY AND DEPTH OF COVER 50/50 SPLIT DB❑X TO BE USED TO TESTED TO THE BOTTOM OF THE RISERS. SOIL AT BACKFILL INSPECTION, SPLIT THE EFFLUENT EQUALLY BETWEEN MANUAL HEADORKS CONTROL BOX WITH THE TWO SALCOR 3G UV LIGHTS, DB❑X TO BE DISC FILTER, FLOW METER, PRESSURE 715 LINFT NETAFIM 0,42 GPH BIOLINE DRIP INSTALLED ON TAMPED GRAVEL TO GUAGES, AND BALL VALVES DISPERSAL SYSTEM PRIMARY AREA PREVENT SETTLING AND MISALIGNMENT 12' EMITTER SPACING, 2 4' DRIPLINE SPACING LOCKING RISER TO SURFACE REQUIRED. EXISTING POST & 6' INSTALLATION DEPTH POLE SHEDS 3®S,®®'+— 715 LINFT NETAFIM 0,42 GPH BIOLINE DRIP DISPERSAL SYSTEM RESERVE AREA 1 ' EMITTER SPACING, 24' DRIPLINE SPACING 6' INSTALLATION DEPTH INTO UNDISTURBED SOILS, PILE OF DISTURBED SOILS TO BE CAREFULLY REMOVED BY THE SEPTIC SYSTEM INSTALLER 1 —6 — — — m ^. 6 — J965 46`/ OF 3/4` FEEDER 65",_._. &RETURN LINES `� 65$ — - ` —SL4 - — — — — — - - — — - - --- (30' MIN) 6 s — — — — — ��. �_ .gym .�,.—. �_...,.,..,...-R .-..• .�� �..a. ....n" EXISTING R❑ KERY 6 — — — — — r- -- �- 00.5 NETAFIM AIR GUARDIAN AIR VAC RELIEF VALVES SCH40 SLEEVE V R L N ❑M AR GE BATHROOM TO BE UPGRADIENT OF DRIP CLEAN❑UTS EXISTING 32'x32' NEW D3034 4' SYSTEM AND AT LEAST 10' AWAY REQUIRED EVERY GARAGE WITH PVC TL & FIFTY FEET BATHROOM FOR CLEAN❑UT PERSONAL USE -- °-�- � ---- — EXISTING DRAINFIELD AREA ONLY. DETACHED 102.5 ___----------- STRUCTURE - — — — ` — COVENANT TO BE ABANDONED REQUIRED AT ev STUB OUT RELEASE , EXISTING COVERED lot PARKING AREA '. EXISTING DRIVEWAYS. a. ti z44 a: � . ` EXISTING SES'TIC TANK x , ` , TO BE PUMPED AND CRUSHED TANK ABANDONMENT FORM TO ? BE PROVIDED WITH ASBUILT ' �ft NEW SYSTEM o' NOTEi PUBLIC HEALTH SEATTLE/KING COUNTY TITLE 13 N TABLE 13.28-2 REQUIRES THAT A SEPTIC DESIGN DELINEATE AN AREA FOR STORM WATER INFILTRATION AND/OR DISPERSION, THE AREA SHOWN ON THIS DESIGN IS SIMPLY AN AREA THAT MEETS THEIR REQUIREMENTS AND SHOULD NOT BE CONSTRUED AS A STORM WATER SYSTEM DESIGN. ONLY A LICENSED ENGINEER CAN DESIGN A STORM WATER SYSTEM. r BI❑ MICR❑BICS MICR❑FAST 0,625 AEROBIC UNIT IN CUZ CONCRETE W.T< 1650/2 TANK OUTLET EL 92.5 DESIGN CONTROL POINT PROPOSED BASE OF EXISTING NW 24'x24' HOUSE CORNER EL 94.5 GARAGE RHOMBUS IFS 5' PANEL L❑CATI❑N , ■ 1 ■ EXISTING DRIVEWAYS EXISTING WATER LINE_ 1 '■ r ■• rl �` [1129:rLIM ■ J FUTURE STUB BOTTOM FLOOR ELEV 94.0 EXISTING HOME TO BE EXPANDED INTO A FOUR BEDROOM SINGLE FAMILY RESIDENCE EXISTING PLUMBING STUB❑UT EL 101.5 I SOIL LOGS r 2. 1 �d • ,x SANDYi� 60'r ■' rSANDS 4. 1 ► ■* .i' ■' rSANDS 5. r rLOAM, ■.MY MEDIUM SANDS,■ r SILT LOAM Amman Septic DC,51cjn5, Inc. 14585 846-th Dr, SE Monroe, WA 98878 FEE TO BE CHARGED FOR FINAL INSPECTION SEE WWW,GOTPERKZOM Tax Parcel #1515320-0481 (360) 794-7809 ❑fflce (425) 501-5195 Cell (360) 794-5408 Fax