Loading...
22-105194a -^sBuilding - Single Family City of Federal Way Permit • Community Development Dept: 33325 8th Ave S Federal Way, WA 98003 Inspection Request Line: (835-3050 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: THE WOODLANDS AT REDONDO CREEK LOT 2 Project Address: 1922 S 302ND ST Parcel Number: 952651 0020 Project Description: BLUEBEAM - Construction of a 2335 square foot 2-story single family residence with a 9 square foot covered entry and an attached 395 square foot garage. Includes plumbing and mechanical Owner Appl ant Contractor Lender SSHI LLC DBA D R HORTON INC JESS BOSANCUD R HORTON D R HORTON OWNER IS LENDER 11241 SLATER AVE NE SUITE 20C 11241 SLATER AVE NE SUITE 120 11241 SLATER AVE NE SUITE 120 KIRKLAND WA 98033 KIRKLAND WA 98033 KIRKLAND WA 98033 USA Census Category: 101 - New Single Family House Includes: # 1 #2 #3 #4 Occupancy Class: R-3 Construction T e: Type V - B Occupancy Load: Floor Area (sq. ft.) 2,335.00 Additional Permit Information New / Additional Sq. Feet - 1 st Floor 945 New / Additional Sq. Feet - 2nd Floor.... . 1390 New / Additional Sq. Feet - 3rd Floor. .................... 0 Occupancy #1 - Area (Sq. Feet).............................. 2335 New / Additional Sq. Feet - Basement_.,. ....... 0 Basic Plan? ............................................................ No Occupancy #1 - Construction Type.. .. Type V - B New / Additional Sq. Feet - Deck .............. New / Additional Sq. Feet - Garage. ............... 395 Mechanical to be Included?..................................... Yes Plumbing Work Valuation? .............. .................: 20000 Mechanical Work Valuation?,...._.... ... .......... 20000 Number of Stories ................................................... 2 New / Additional Sq. Feet - Other........................... 90 Plumbing to be Included?.. Yes New / Additional Sq. Feet - Total- .......................... 2820 Will Certificate of Occupancy be Issued ............... Yes Occupancy #1 - Use... Residence (1 or 2 family) Comprehensive Plan Designation.... SF - High -Density Zoning Designation....,., ... .. S 5.0 I PERMIT EXPIRES Tuesday, 4 July, 2023 Permit Issued on Thursday, January 5, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: Lklit Date. low E! 'i City of Federal Way Certificate of Occupahcm This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed bv Citv staff. Tenant Name: THE WOODLANDS AT REDONDO CREEK LOT Permit # 22-105194-00-SF Address: 1922 S 302ND ST Includes: #1 #2 #3 #4 Occupancy Class: R-3 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 2,335.00 Owner Name: SSHI LLC DBA D R HORTON INC Owner Address: 1S - ER AVE NE SUITE 200 Z1241LAND'WA 98033 Building Oftlicial Date The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the ownerl occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. THIS CARD IS TO REMAIN ON -SITE CITY OF s ction, Inspection Record Federal Way INSPECTIONREQUESTS: (253) 35-305 PERMIT : 22 1514 00 Address: 12 S 32 Project: SSHI LLC DBA D R HORTON INC FEDERAL WAYA 98003 Scheduled inspections may be failed if this card is not on -site. 00 N(Yl` LDSF ` JH -CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. I SWM Precon Site Mtg (4400) Site Assessment (Erosion) (4365) F31 Footings/Setback (4110) Approved To be done PRIOR to breaking ground Approved to place concrete By Date y Date y Date El Foundation Wall (4115) Drainage/Downspout (4040) Plumbing Groundwork (4190) Approved to place concrete Approved to backfill Approved to cover y -- Date ByDate �, / y Date ZL7, I Lo El Slab/Concrete Floor (4255) Underfloor Framing (4285) L1 Floor Sheathing (4105) Approved to place concrete Approved to sheath floor Approved to install flerori g By Date By Date Y QS Date t Shear Walls (4245) 1 Roof Sheathing (4220) Rough Plumbing (4230) . Approved to install siding Approved to install rooldn 1By Approved I TL��_ Y Date y Date ;� Date- "l Mechanical Rough -in (4165) E�t Gas Piping (4125) 15 Fire/Draft Stops (4095) Approved Approved to release test Approved � By Date By Date / By Date �] ±E3- 16 Interim Erosion Control (4370) Prior to scheduling a Framing inspection; Framing(4120) Approved Electrical, Plumbing &Mechanical Rough -in and Fire/Draft Stop inspections must be signed- off and approved. IBC 109.3.4 :By Approved to insulate- Date Y Date 18 Insulation (4150) 19 Gypsum Wallboard Nailing (4130) 20 Final Erosion Control (4375) Approved to install mil board Approved to install mud tape Approved B Date By Date y Date 21 Final - Mechanical (4065) 22 Final - Plumbing (4075)" Final - Building (450) Approved Approved )i Date Approved Date 61-2do B Date Y U y y rQU f r y Rough Electrical Final Electrical it o ay El Approved Approved Approved y Date y Date ByDate tITY 01p Foderal Vft I wilding Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: PERMIT#: IF YOU HAVE QUESTIONS CALL (253) 835-___2� WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835450 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page - of icITY Op Federal My ® I tuildling Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE A DDRESS: PERMIT#' IF YOU HAVE QUESTIONS CALL (253)835- 2,C ZT WHEN CORRECTIONS HAVE BEEN MADE, CALL ((253)18 5-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page - of -huilding Division CITY OF 33325 Eighth Avenue South Federal Way, WA 98003-6325 Federal Way Phone 253-835-2607 Fax 253-835-2609 VA�& CORRECTION NOTICE ADDRESS: � �OV"�- St. PERMIT#: ALI IF YOU HAVE QUESTIONS CALL (253) 835-_Ilc� _7 WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. q[_4 DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page - of rRuilding Division iciTy OF 33325 Eighth Avenue South Federal Way, WA 98003-6325 Wjbk Federal Way Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE l� I - WHEN CORRECTIONS HAVE BEEN MADE, L = RE -INSPECTION. SEE BACK OF CARD DAYS.FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 tY - DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of IN uli In Division 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 t.;ORRECTION NOTICE ADDRESS: P IF YOU HAVE QUESTIONS CALL _?'F ® I WHEN CORRECTIONS HAVE BEEN 717 DAYS. CALL (253) 835-3050 FOR REINSPECTON. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 ATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of