Loading...
22-103400City of Federal Way Community Development Dept. 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Plumbing Permit #:22-103400-00-PL Inspection Request Line: (253) 835-3050 Project Name: DICK'S DRIVE-IN Project Address: 32048 PACIFIC HWY S Project Description: BLUEBEAM - Plumbing work for new restaurant building. Parcel Number: 762240 0015 Owner Applicant Contractor MERLONE GEIER PARTNERS SCOTT MILLERMETRIX ENGINEERS HOLMBERG COMPANY (PLUMBING) C/O RYAN LLC HILARY RAYMOND 227 WILLIAMS AVE S HOLMBC*794M (7/2/23) PO BOX 847 RENTON WA 98057 12002 SE 9TH PL SUITE 300 CARLSBAD CA 92018 BELLEVUE WA 98005 Drains Rain Water Systems Water Closets Plumbing Fixtures 35 Lavatories 6 Sinks 4 4 Other Plumbing Fixtures 2 28 Urinals 2 PERMIT EXPIRES Monday, 22 May, 2023 Permit Issued on Wednesday, November 23, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of i and4i4City of Federal Way. Owner or agent: Fr Date. Fig 1 HOLMBERG MECHANICAL 15400 SE 30th Place, suite 100 Bellevue, WA 99007 425-822-2233 HOLMBERGCOXOM kCCOUN I' # MECHANI est,1949 AL BUILDING SYSTEMS. ENSURING PROGRESS. BACKFLOW PREVENTION ASSEMBLY TEST REPORT N;\N4b: OF PREMISE Diek's Federal Way_ Commercial N Residential ❑ SERVICE ADDRESS 1701 S Commons C1TYFederal Wa ZIP 98003 CONTACT PERSON Ken Frazier ------- PIIONF (206)940-3365 ------ FAX ( ) LOCATION OF ASSr:a-Il3Ix North East side of the buildin DONVNSTREAM PROCESS Irrigation DCYA K ❑ PVBA ❑ OTHER NE-W INSTALL ® EXISTING ❑ REPLACEN9ENT ❑ OLD SER. # PROPEIR INSTALLATION? 1'ES 91 NO ❑ MAKE 01;.ASSEN16L1' &T__S_ DEL a7M3QT.SERIAI, No. 212114 _SIZE 3/4" Air Gap Inspection: Supply Pipe Diameter: Separation: 19 PASS ❑ FAIL ❑ LINE PRESSURE: 45 PSI REMARKS: WSDOH APPROVED ASSEMBLY? YES I&I NO ❑ TESTERS SIGNATURE: Christian F._ _ TESTERS NAME PRINTED: Christian Faria REPAIRED BY: CERT. No. B6854 DATE 06/30/2023 TESTERS PHONE 4 (425 ) 324-1598 DATE FINAL TEST BY: CERT. NO. DATF. CALIBRATION DATE 01 i25i23 GAUGE # 01 21 091 2MODEL 835 SERVICE RESTORED? YES M NO ❑ I c•ertift that this report is accurate, and I have used ilAC 146-190-490 approved test nullaods aiid test equipment. HOLNIBERG MECHANICAL 15400 SF 30th Place. suite 100 Bellevue, WA 93007 425_A22.2233 HOLMBERGCO.COM *14e) ECHANI est,1949 AL BUILDING SYSTEMS. ENSURING PROGRESS. BACKFLOW PREVENTION ASSEMBLY TEST REPORT ACCOt:NTt- Dick's Federal Way Commercial N Residential ❑ NAiNIE OF PRI:NIISE —- S Commons cvrYFederal Way ZIP 98003 SERVICE; ADDRESS _1701 _ _ -- CONTACT PERSON Ken Frazie PHONE (206040-3365 FAX(_ -- LOCATION OF ASSENIBLY Rm 108 Soda Room DON1'NSTREAM PROCESS Soda machine DCVA ❑ RI'13A N PN'BA ❑ OTHER NF'W INSTALI, ® EXISTING ❑ REPLACEMLN"r ❑ OLD sI:R. # PROPER INSTALLATION? 1'FS KI NO ❑ MAKE OF .nssE�-IBLY WATTS _.MODEL _LFaOSQT _SERIAI. No. _ 373445 SIZE 1 /2" DCVA1RPBA DCVA/RPBA RPBA PVBl 5VBA INITIAL CHECK VALVE NO.I CHECK VALVE N0.2 AIR INLET NED AT 3 9 PSID TEST OPENED A•I'— _PSID LEAKED ❑ I.EnKID ❑ #1 CHECK 8.2 PSID ❑ DID NOT OPEN PASSED 8.2 PSID CT PSID AIR GAP OK'? _ Y FAILED ❑------_----_-- ---PSID CONTINUEDTO FULLY OPEN? Y N REPLACE PART L't.l:�\\ RGPLACE Pr]RT CLf=•1ti REPLACE: I'AKT CHECK VALVE NEW ❑ ❑ ❑ ❑ ❑ ❑ FIELD AT PSID ❑ PARTS ❑ ❑ — ❑ ❑ ❑ ❑ LEAKED AND ❑ ❑ - ❑ ❑ REPAIRS ❑ ❑ CLEANED ❑ El❑ ❑ El— ❑ ❑ REPnllir_D El liar .--T L - REPAIRS LE:AKFD ❑ LE'AKED ❑ OPENED A I —__._PSID AIR INLET PSID PASSED ❑ PSID —PSID 91 CHECK PSID CHK VALVI: PSID FAILED ❑ Air Gap Inspection: Supply Pipe Diameter: _ Separation:.. 91 PASS ❑ FAIL ❑ LINE PRESSURE:_45 PSI REMARKS: — — __ WSDOI-I APPROVED ASSEMBLY? YES ® NO ❑ TESTERS SIGNATURE: Christian F. TESTERS NAME PRINTED: Christian Faria REPAIRED BY: CERT. No. B6854 DATE 06/30/2023 TESTERS PHONE # (425 ) 324-1598 n ATE. FINAL TEST BY: CERT. NO. DATE CALIBRATION DATE 01 i25/23 GAUGE # 01210912MODEI---- _ _835 _ SERVICE RESTORED? YES M NO ❑ l c•ertifP that this report i.v acc•urale, and l have used 14:4C' 246-290-490 approved test methods and lest egaipmeitt. THIS CARD IS TO REMAIN ON -SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 22 103400 00 Address: 32048 PACIFIC HWY S Project: MERLONE GEIER PARTNERS, FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 Plumbing Groundwork (4190) Rough Plumbing (4230) Final - Plumbing (4075) Approved to cover Approved Approved By A-^j Date :L 17-1 23 By i Date 'J3 f 21 By Date �J L3 Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date