Loading...
20-103976-SITE Plan-01-26-2021-V2DIMENSION NOTES: DENOTES CENTERLINE DIMENSION DENOTES EDGE DIMENSION SYMBOL INDICATES SIDE m c0 0 n FLOOR ABBREVIATIONS C CARPET V VINYL T TILE H HARDWOOD M MARBLE P PERGO ABBREVIATIONS ABV ABOVE BM BEAM BRG BEARING GONG CONCRETE DBL DOUBLE DR DOUGLAS FIR DIA DIAMETER FND FOUNDATION FTG FOOTING FLR FLOOR W.F. HEMLOCK / FIR HT HEIGHT MAX MAXIMUM MIN MINIMUM O.C. ON CENTER PCKT POCKET fE PLATE PLCS PLACES P.T. PRESSURE TREATED STD HDR STANDARD HEADER SUBFLR 6U5FL0OR T4G TONGUE 4 GROOVE TYP TYPICAL V.T.O.S. VENT TO OUTSIDE 0 62'-0" EIIII I I I I I I .II I ______________________________________________________________IT______________________________________________- I I r' I I r' I I r' I I d I I I I I I I 4 I I I I I I d I I HEAT I PUMP I I O C d d a a WTR HTR FURNACE 0 STEEL POST o WORK SHOP 14'-2 Ire" X 15'-6 Ir2" 4" THIC GONG SLAB FLAT CLG 9'-3" a CHARGING STATION n C d d dd d d ---� -- I ' ril II II I I II II II � �---------------L� r , _ PROVIDE ROUGH IN I Ir' •� PLUMBING ONLY FOR L-J FUTURE FIXTURES AS SHOWN THREE CAR GARAGE 30'-4 Ire" X 22'-10 Ir2" INT DIM 4" THIC GONG SLAB FLAT CLG g 9'-3" [i3 UNFINISHED BASEMENT 48'-5" X 36-I0Ir2" 4" THIC GONG SLAB FLAT CLG e 9'-3" CHARGING STATION -------------------- ----- ---------------------- IIII X 8'-0" TALL ROLL UP GARAGE I I `,91-0" X 8'-0" TALL ROLL UP GARAGP' I DOOR W/ JACK SHAFT OPENER I I `,DOOR W/ JACK SHAFT OPENER-' I I ,• `� I I I ,� •� I I I ,• `� I ------------------------------------------- -------------------------- - ---------------------------------------------' '-------------------------- �� 33'-10" NOTE: ALL FUTURE WORK AT UNFINISHED BASEMENT TO BE UNDER SEPERATE PERMIT VERIFY PERMIT REQUIREMENTS AT TIME OF FUTURE IMPROVEMENTS Contact Labor & 30 Industries for lift O r+n spe-E-ti an 16 I L------- -15j'I //// T STORAGE I ---------- ELEVATOR`CIFlip UNDER i---------13 INSTALL PER STAIRS I12 MANUF. SPECS II ------- --------- 0 9 8 ---------� I 5 I I 4 3 2 2 ----------- 3� ENTRY TILE FLR COFFERED CLG 5 14'-6" I. V-4" L 111/411 L 11 I. 62'-0" 13'-6 1/2" 1/411 = 11-011 d a a (2) 2'-6" X 5'-0" CASEMENT (MULLED) a 14'-1 1/2" 5 3 CODE EDITIONS 2015 INTERNATIONAL BUILDING CODE (15C) + WAG 51-50 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) + WAG 51-51 2015 INTERNATIONAL MECHANICAL CODE (IMC) + WAG 51-52 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FIRE CODE (IFC) 2015 UNIFORM PLUMBING CODE (UPC) + WAG 51-56 4 51-51 2015 WASHINGTON STATE ENERGY CODE (WSEC) Ln m v cn v SMOKE DETECTOR NOTE: GLAZING NOTE: ALL SMOKE DETECTORS SHOWN ON THE SMOKE PLAN WITH SYMBOL AT RIGHT TO BE DETECT ALL WINDOW UNITS TO HAVE MINIMUM 'U' FACTOR OF 024 INSTALLED PER 2015 IRC REFER TO FULL CODE FOR ALL VERIFY WITH WINDOW MANUF. REQUIREMENTS 110V W/ PRIOR TO ORDERING BATTERY ALL DETECTORS TO BE LABELED IN ACCORDANCE WITH UL REQUIREMENTS ALL DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND BE EQUIPT WITH BATTERY BACKUP WHEN THE PRIMARY POWER IS INTERRUPTED WHERE MULTIPLE DETECTORS ARE SHOWN ON THE PLAN, THE DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE CARBON MONOXIDE ALARMS TUB I N S U L A T I O N ALL CARBON MONOXIDE DETECTORS CM SHOWN ON THE PLAN WITH SYMBOL` e VAPOR BARRIER ON INSULATION INSTALLED TO THE RIGHT SHALL BE INSTALLED BEHIND BATHTUBS OR OTHER SUCH AREAS, PER 2015 IRC REFER TO FULL WHERE THE BACKING OF THE INSULATION DOES CODE FOR ALL REQUIREMENTS NOT PRESS AGAINST THE BACK OF THE GYPSUM WALLBOARD OR OTHER COVERING, MUST BE ALL DETECTORS TO BE LABELED IN ACCORDANCE UNBACKED OR HAVE A BACKING WITH A WITH UL LISTINGS FOR SINGLE STATION ALARMS FLAMESPREAD RATING NOT TO EXCEED 25 AND A SMOKE DENSITY RATING NOT TO EXCEED 450. IF UNBACKED INSULATION IS USED, A MOISTURE BARRIER MUST BE INSTALLED WITH THE SAME GARAGE NOTE : SAME FIRE59READ AND SMOKE DENSITY GARAGE SHALL BE SEPARATED RATINGS STATED ABOVE FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN Ir2" GYPSUM BOARD APPLIED ON THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED DENOTES SIMPSON HOLDOWN REFER TO ENGINEERING SHEETS FOR STRAP CALLOUT AND NOTES DENOTES 5IMP50N HOLDOWN REFER TO ENGINEERING SHEETS FOR REQUIRED HOLDOUIN ODENOTES SHEAR WALL REFER TO SHEET FOR REQUIRED SHEATHING AND NAILING 0 2' 4' 6' 8' 12' SCALE 1/4" = 1'-0" GENERAL NOTES: FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5r8" 'TYPE X' GYPSUM BOARD OR EQUIVALENT WHERE THE O ALL DIMENSIONS ARE FRAMING SEPARATION IS A FLOOR/CEILING TO FRAMING AND BASED ON ASSEMBLY, THE STRUCTURE SUPPORTING ACTUAL MATERIAL THICKNESS THE SEPARATION SHALL ALSO BE O ALL WINDOWS UNITS TO BE MILGARp PROTECTED BY NOT LESS THAN Irz" GYPSUM VINYL FRAMES W/ ARGON GAS AND BOARD OR EQUIVALENT LOW 'E' COATING PROVIDE SCREENS AT ALL OPERABLE UNITS O VERIFY ALL ELECTRICAL W/ DRYER VENTING NOTE: OWNER/BUILDER ON SITE PRIOR TO ALL CLOTHES DRYERS SHOWN SHALL BE INSTALLED INSTALLING AND EXHAUSTED IN ACCORDANCE WITH 2O15 IRC AND THE MANUFACTURER'S INSTRUCTIONS UNLESS SPECIFIED BY THE MANUFACTURER TEMPERED GLAZING NOTE THE MAXIMUM LENGTH OF DRYER VENTING SHALL BE PER 2015 IRC WINDOWS LABELED 'TEMPERED' ON FLOOR PLAN WHICH ALLOWS A TOTAL LENGTH OF SHALL COMPLY WITH 2O15 IRC FOR MANUF. LABEL 35'-0" WITH A REDUCTION FOR EACH DRYER DESIGNATING THE TYPE AND THICKNESS OF GLASS EXHAUST DUCT FITTING USED AND THE SAFETY GLAZING STANDARD WITH WHICH e IT COMPLIES AND SHALL BE VISIBLE IN THE FINAL WHERE THE EXHAUST DUCT IS CONCEALED WITHIN s INSTALLATION THE BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE PROVIDED AREAS REQUIRING SAFETY GLAZING SHALL BE WITH A PERMANENT LABEL OR TAG WITHIN 6'-O" NOTED ON THE FLOOR PLAN AND COMPLY WITH OF THE INTERIOR CONNECTION POINT 2015 IRC REFER TO 2015 IRC SECTION M 1502 FOR ADDITIONAL REQUIREMENTS AND EXCEPTIONS UJTR HTR NOTE:: EGRESS NOTES ALL WINDOWS LABELED AS EGRESS IN SEISMIC ZONES D2, WATER ON PLAN MUST MEET THE MINUMUM HEATERS SHALL BE ANCHORED OR REQUIREMENTS FOR EGRESS WINDOWS STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE EGRESS WINDOWS SHALL HAVE A MOTION. STRAPPING SHALL BE AT MINIMUM NET CLEAR OPENING AREA OF POINTS WITHIN THE UPPER THIRD ANp 5.1 SOFT. THE MINIMUM NET CLEAR LOWER THIRD OF ITS VERTICAL OPENING HEIGHT SHALL BE 24" THE DIMENSION MINIMUM NET CLEAR OPENING WIDTH APPLIANCES CAPABLE OF PRODUCING SHALL BE 20" HEIGHT TIMES THE WIDTH A SPARK OR FLAME LOCATED IN A SHALL NOT BE LESS THAN 5.1 SQFT. GARAGE SHALL BE INSTALLED WITH ALL WINDOWS LABELED AS EGRESS THE PILOT AND BURNERS OR HEATING ON PLAN SHALL HAVE AN OPENING HEIGHT ELEMENTS AT LEAST 18" ABOVE THE OF NOT MORE THAN 44" ABOVE FINISHED FLOOR SURFACE FLOOR LEVELS NATURAL GAS FIRED FURNACE AND WTR HTR TO VENT TO OUTSIDE F I R E B L 0 C K I N G N 0 T E: WTR HTR TO HAVE PRESSURE PROVIDE 2"X FIREBLOCKING RELIEF VALVE TO DRAIN BY AT ALL CONCEALED SPACES OF STUD WALLS GRAVITY TO OUTSIDE WAND PARTITIONS INCLUDING FURRED SPACES, IN ADDITION TO REQUIRED PRESSURE AT THE CEILING AND FLOOR LEVELS AND AT 10'-0" RELIEF VALVE, AN APPROVED AND INTERVALS BOTH VERTICAL AND HORIZONTAL LISTED EXPANSION TANK SHALL BE INSTALLED PER THE MANUF. SPECIFICATIONS SHOWER NOTES HOUSE VENTILATION NOTE: ALL SHOWER RECEPTORS SHALL BE TESTED FOR WATERTIGHTNESS BY FILLING WITH WATER TO THE GAS FUF MACE TO BE PROVIDED WITH FRESH LEVEL OF THE ROUGH THRESHOLD. THE TEST PLUG AIR DUCT TO EXTERIOR TO SUPPLY SHALL BE SO PLACED THAT BOTH UPPER AND UNDER FRESH AIR TO THE RESIDENCE DUCT SIDES OF THE SUB -PAN SHALL BE SUBJECTED TO THE SHALL HAVE A MOTORIZED DAMPER TEST AT THE POINT WHERE IT IS CLAMPED TO THE DRAIN AND CONNECT TO THE FURNACE FAN SYSTEM AND PIN TIMER TIMER SHALL WHEN GYPSUM IS USED AS A BASE FOR TILE WALL PANELS BE SET TO RUN 4 HOURS PER DAY (MIN) FOR TUB, SHOWER, OR WATER CLOSET COMPARTMENT WALLS AT TIME OF FINAL INSPECTION WATER RESISTANT GYPSUM WHOLE HOUSE FAN LOCATED IN UTILITY BACKING BOARD SHALL BE USED. WATER RESISTANT GYPSUM ROOM SHALL BE TIED TO THE SYSTEM BOARD SHALL NOT BE USED IN THE FOLLOWING AREAS TO EXHAUST STALE AIR OVER A VAPOR RETARDER IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY SUCH AS SAUNAS, STEAM ROOMS, OR GANG SHOWER ROOMS. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12" O.C. pF y � AND��' WA��I�O�� 7 r. /2Q z r571 "s�� �XV �2A L ` S, S'IDNAIt, ASPEN CREEK ENGINEERING RESPON51BLE FOR LATERAL AND GRAVITY REQUIREMENTS ONLY EXHAUST FAN NOTE: LOCATION TYPE MAKE MODEL CFM SONES DUCT LIGHT UTILITY WHOLE HOUSE NUTONE ZNIIO 110 03 b" NO BATH SPOT NUTONE QTXENOW 90 03 b" YES BUILDING AREAS O MAIN FLOOR AREA = 12 5 8 SQ. FT. O UPPER FLOOR AREA = 2 4 3 2 SQ. FT. O TOTAL LIVING AREA = 3 (6 9 0 SQ. FT. O UNFINISHED ATTIC = 1 9 0 SQ. FT. O UNFINISHED BASEMENT = 0 SQ. FT. O GARAGE AREA = 10 8 5 SQ. FT. O FRONT PORCH AREA = 4 2 SQ, FT. O REAR DECK AREA = 12 0 SQ. FT. F R A N C H I N I DESIGN GROUP ARCHITECTURE - PLANNING 206-423.4644 1708 TACOMA PT. DR. E. LAKE TAPPS, WA. 98391 FRANCHINIDESIGN@COMCAST.NET SCALE: 1/411 = 1'-011 ENGINEERING: ASPEN CREEK ENGINEERING BLDG DEPT, CITY OF FEDERAL WAY CHECKED BY: PRINT DATE: 9.5,20 REVISIONS 11.1.19 PRELIMINARY 55F 1.24.20 PRELIMINARY 55F 2.1.20 PRELIMINARY 55F 4.9.20 PRELIMINARY 55F 4.14.20 PRELIMINARY 55F 5.5.20 PRELIMINARY 55F 5.1920 PRELIMINARY 55F 8.24.20 ENGINEERING 55F 9.5.20 BLDG DEPT 55F BUILDER APPROVAL: DATE DATE OWNER APPROVAL: DATE DATE PLAN NUMBER PROJEGT H I L L RESIDENCE RESUBMITTED 1/26/2021 CITY OF FEDERAL WA OMMUNITY DEVELOPME FEDERAL WAY W A 5 H I N G T 0 N SHEET TITLE: MAIN FLOOR PLAN SHEET NUMBER: �oVW T m