20-100366CITY OF
Federal Way
RECEIVED
JAN 2 8 2020
CITY OF FEDERAL WAY
CDM UNITY DEVELOPMENT
Eligible Facilities Request
DEPARTMENT OF COMMUNITY DEVELOPMENT
33325 8th Avenue South
Federal Way, WA 98003-6325
253-835-2607; Fax 253-835-2609
yvww.ci1 of(etleraLvsw .corn
11
FILE NUMBER _AA —LL - __Z -..0 _0 - AD Date
Applicant
ie
506 Second Ave. Suite 1533
Seattle I WA 1 98104
206-549-3849
ronnie.hyde@coreoneconsultants.com
Site Address: 4451 SW 313th St Federal Way. WA98023 (Dash Point Rd. & 47th Ave. SW)
Parcel#: 2116500090
Project Name: SS65 Dumas Bay LTE 6C
ELIGIBLE FA'CI ITIES'SUS' 1t117TTAL REQUIREMENTS
Use this checklist to help gather all of the required information and documents in order to submit an eligible
facilities request pursuant to Federal Way Revised Code (FWRC) 4,24,020. Please note, incomplete applications
will not be accepted.
Submitted
® I Completed Eligible Facilities Checklist (following)
Check, cash, Visa/MasterCard for applicable fees
Site Plan —Three Copies
1. Minimum plan size of 11" X 17".
2. North arrow.
3. Drawn to scale, dimensioned, and labeled.
4. Building footprint(s), including square footage.
5. Location and dimensions of existing structures, property lines, sidewalks, easements, street
edges, mechanical equipment, fencing, rockeries, and retaining walls.
Elevation —Three Copies
1. Minimum plan size of 11" x 17".
2. Drawn to scale, dimensioned, and labeled.
3. Front, rear, and side (labeled as north, south, east, and west) building elevation of existing
and proposed structures.
4. Height of structure calculations.
S. Roof -top and ground based mechanical equipment screen details.
Bulletin 081- September 24, 2018
Page 1 of 3
k:\Handouts\Eligible Facilities Request
ELIGIBLE FACILITIES CHECKLIST
Proposed modifications to an existing tower or base station must meet at least one of the three threshold criteria
below for an eligible facilities request. For definitions please refer to FWRC 19.256.020, Check all that apply.
Collocation of new transmission equipment
Removal of transmission equipment
X Replacement of transmission equipment
Is the proposed modification a substantial change as defined in FWRC 19.256.020? To determine, fill in the
appropriate information below. If the application does not meet all of the criteria below, then the project does
not qualify as an eligible facility and It is unnecessary to complete this form. To determine the correct review
process, refer to FWRC Chapter 19.256, "Wireless Communication Facilities."
Criteria 1
For towers other than towers in the public rights -of -way, It does not increase the height of the tower by more
than 10 percent, or by the height of one additional antenna array, with separation from the nearest existing
antenna not to exceed 20 feet, whichever is greater.
For other eligible support structures, it does not increase the height of the structure by more than 10 percent,
or more than 10 feet, whichever is greater.
Existing height of the structure: 62 (ft/ In) Proposed height of the structure: 62 (ft/ In)
Distance of proposed array from nearest array: NIA (ft/ in)
Criteria 2
For towers other than towers in the public rights -of -way, It does not involve adding an appurtenance to the
body of the tower that would protrude from the edge of the tower more than 20 feet, or more than the width
of the tower structure at the level of the appurtenance, whichever is greater.
For other eligible support structures, it does not involve adding an appurtenance to the body of the structure
that would protrude from the edge of the structure by more than six feet.
What Is the existing width of the structure at the level of the appurtenance? 3 ______ (ft/ in)
What is the proposed distance the appurtenance will protrude from the structure? 3 (ft/ in)
Criteria 3
For any eligible support structure, it does not involve installation of more than the standard number of new
equipment cabinets for the technology involved, but not to exceed four cabinets; or,
For towers in the public rights -of -way and base stations, it does not involve installation of any new equipment
cabinets on the ground if there are no pre-existing ground cabinets associated with the structure; or
It does not involve installation of ground cabinets that are more than 10 percent larger in height or overall
volume, than any other ground cabinets associated with the structure.
How many new equipment cabinets are proposed? _0
Bulletin 081— September 24, 2018 Page 2 of 3 k:\Handouts\Eligible Facilities Request
Criteria 4
■ For all existing facilities, it does not entail any excavation or deployment outside the current site.
Will any excavation or equipment installation occur outside of the current site of the structure?
❑ Yes ® No
Criteria 5
o For all existing facilities, the modification does not defeat the concealment elements of the eligible support
structure.
Please describe any existing and proposed concealment elements: Antennas are slim mounted on PSE
Utility Pole. Antennas are painted to match
Will the proposal increase the visibility of the facility? ❑ Yes I@ No
Criteria 6
■ The modification complies with conditions associated with the siting approval of the construction, or
modification of the eligible support structure or base station equipment; provided, however, that this
limitation does not apply to any modification that is noncompliant only in a manner that would not exceed
the thresholds identified above.
IdeNn�� known conditions associated with previous approvals of the existing facility.
Will the proposal violate any of the above conditions? ❑ Yes ❑ No
If yes, explain. N/A _
To Be Completed By Staff
Is this an Eligible Facility Request? X Yes ❑ No
Does the proposal constitute a substantial change? ❑ Yes $ No
In accordance with FWRC 4,24.020, this application is hereby:
Approved ❑ Denied
Director, Community Development Department Date
Bulletin 081—September 24, 2018 Page 3 of 3 k:\Handouts\Eligible Facilities Request
�1
William Golding
From:
William Golding
Sent:
Wednesday, February 12, 2020 11:47 AM
To:
'ronnie.hyde@coreoneconsultants.com'
Subject:
Approved Eligible Facilities Request
Attachments:
Approved Development Plans.pdf; Approved Site Plan.pdf, Eligible Facilities Request.pdf
Good morning Ronnie Hyde,
Attached please find the approved Eligible Facilities Request (file # 20-100366-00-AD) and associated site plans for Core
One Consultants on behalf of AT&T proposed modification to an existing telecommunications facility, site number SS65
(Dumas Bay) located at 4451 SW 313"' St., Federal Way, WA 98023 (parcel # 211650-0090). The original request to
remove (4) existing panel antennas & (2) RRH's to be replaced with (4) proposed panel antennas, (8) proposed RRh's &
(4) proposed diplexers on existing 52'-0" wood utility pole on equipment located on grade with signature/enclosures is
attached to this email and will also be mailed to you.
Prior to any site work, an electrical permit is required from the City's Building Division. An electrical permit can be
applied for online or over the counter. Please contact the Permit Center at 253-835-2607 or
ermitcenter ci offederalwa .com if you have questions regarding electrical permits.
All the best,
Will Golding
Planning Intern
Federal Way
33325 8t" Avenue South
Federal Way, WA 98003-6325
Phone: 253/835-2622
www.cityoffederalway.co
}
Y.
TRUE NORTH ARROW SHOWN ON,-'.' C�i �•l
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERIFIED ��i f• Z><r .ar ,� sa+*4y
PARCEL #2116500080 :�'
1� I iii
LOT
1 �•
���wam-
• 's+� 1 'r
cc �" � ��Lr'�•Yd
APPROXIMATE LOCATION OF
EXISTING PROPERTY LINE, TYF
A P P R 0V9 D
PLANNING
City of Federici Way
Dept. of Community Peveio ment
Permi # a0-1003(g -oo -1, 1
By iFItRM
Date A - l a - 61a�
z NOTES:
} ' 1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
iT{{ - - ° •i' �' �iA. PACIFIC TELECOM SERVICES DATED 12/07/2011
• r.. 2 CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
• CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
1 I r
• o ��� I DISCREPANCIES TO THE ENGINEER.
;•`� jT..:'a1.. - � >y • ¢ < �IDi� ° ?F s = Ctn�y°. �y�p{ 'mow
�1
PARCEL #2116500070 •�
1F
LOT 7
.0
L Ek1STIMG
BUILDING 7
�r : C7 5
/
•
jR
�
�
titr� �%•
-
y! ' • 0 �� ��H
�
I/
1
PARCEL 500090
LOT 9
E1CSTiNE /
LEXISTIkG
a I 71 47 BUI DING 7
elm -
AA
i
� • � ....
-
• ���p
' 6`
tM1f
I
EXISTING OVERHEAD
POWER LINE, TYR.
PARCEL #1121039063
7 SITE PLAN
2, q
0 10' 20' 40'
S.W. DASH POINT ROAD
S.W. 313th ROAD
LEXISTING
BUILDING 7
i14t• � a�•MW, '�
0 M o ; $ ^gam • an,,.s�
way --`a � '"� •'' � ¢>':
� • a
'o I
RECEIVED
JAN 2 8 2020
CITY OF FEJEP.AL WAY
COMMUNfTY DEVELOPMENT
at &t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREONE
CONSUL—: !VC USA
506 SECOND AVE, SUITE 1533
SEATTLE, WA 98104
PROJECT N0., 1915U052
DRAWN BY: AF.
CHECKED BY: L -
SUBMITTALS
100% FINAL
ThE 1!•FORMATON GOMAINEO IN THIS 6ET �
OOCL.ME]YIS 19 PROPFAETARY SY NATLPE
ANY LYE OR dSCLd.3JRE OTHER THPN THAT
WHICH RELATES TO THE CLIENT NAM® IS
STRICTLY PROHIBfTE0.
A6E EEPL
DUMAS BAY
SSB5
DASH POINT R❑. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 98023
FA -- 10092B76
SHEET TFI E
SITE PLAN
SHEET NLV.9ER
C-1
_7
PROJECT DESCRIPTION
AT&T PROPOSES TO MODIFY AN EXISTING iELECOMMUNCATIONS FACILITY WITH THE REMOVAL OF (4) EXISTING
PANEL ANTENNAS do (2) EXISTING RRH's TO BE REPLACED WITH (4) PROPOSED PANEL ANTENNAS, (8) PROPOSED
RRH's & (4) PROPOSED DIPLEXERS ON EXISTING 52'--0' WOOD UTILITY POLE.
PROJECT INFORMATION
SITE ADDRESS
DASH POINT RD. & 47th AVE. S.W.
ZONING DISTRICT:
RS9.6 RESIDENTIAL SINGLE FAMILY
FEDERAL WAY, WA 98023
EXISTING USE:
UNMANNED TELECOMMUNICATIONS FACILITY
LATITUDE:
47' 19' 17.00" N
PROPOSED USE:
UNMANNED TELECOMMUNICATIONS FACILITY
LONGITUDE:
122• 23' 30.00' W
OCCUPANCY:
U. S-2
JURISDICTION:
CITY OF FEDERAL WAY
A.P.N.
21 16500090
RF DATA SHEET
DATE ISSUED: 07/17/2019 VERSION: 2.10
DRAWING INDEX
REV
T-1
TITLE SHEET
0
GN-1
GENERAL NOTES 1
0
GN-2
GENERAL NOTES II
0
GN-3
GENERAL NOTES III
0
C-1
SITE PLAN
0
C-2
PARTIAL SITE PLAN
0
C-3
EXISTING EQUIPMENT LAYOUT
0
C-4
PROPOSED EQUIPMENT LAYOUT
0
C-5
PARTIAL EXISTING & PROPOSED SOUTH POLE ELEVATIONS
0
RF-1
EXISTING ANTENNA CONFIGURATIONS
0
RF-2
PROPOSED ANTENNA CONFIGURATIONS
0
RF-3
RF & EQUIPMENT DETAILS
0
S-1
CONSTRUCTION DETAILS 1
0
G-1
GROUNDING NOTES
0
G-2
SCHEMATIC GROUNDING PLAN
0
G-3
GROUNDING DETAILS
0
LEGAL DESCRIPTION
SUBJECT POLE IN RIGHT OF WAY DASH POINT ROAD NEAR 47th AND DASHPOINT ROAD FEDERAL WAY, WA 98023.
SITE PROJECT PARTICIPANTS
NAME
COMPANY
NUMBER
A/E
LEE CAMPBELL
CORE ONE CONSULTING USA
778-805-2166
SAC
RONNIE HYDE
CORE ONE CONSULTING USA
206-549-3849
RF
ANNE LE
AT&T WIRELESS
425-614-5641
LANDLORD
MARTY O'CONNOR
PUGET SOUND ENGERY
425-462-3109
SAC MANAGER
HANNAN RUTKOSKY
MASTEC NETWORK SOLUTIONS
253-579-3503
A&E MANAGER
DANIEL KELLY
MASTEC NETWORK SOLUTIONS
253-579-3503
CM
MIKE SLITHI
MASTEC NETWORK SO TIONS
253-579-3503
PROJECT SCOPE:
LTE 6C
FA#:
10092676
PTN#:
38OAOPE70
PACE NUMBER:
MRWOR040967
SITE NUMBER:
SS65
SITE NAME:
DUMAS BAY
ADDRESS:
at&t
DASH POINT RD. 6 47TH
AVE. S.W.
FEDERAL WAY, WA 98023
SITE TYPE:
UTILITY POLE
CONSTRUCTION DRAWINGS
VICINITY MAP
DIRECTIONS (RTC BUILDING 3: 18221 NE 72nd WAY, REDMOND, WA 98052):
HEAD SOUTHEAST ON NE 72nd WAY TOWARDS 164th AVE NE, TURN RIGHT ONTO 164th AVE NE, TURN RIGHT ONTO
BEAR CREEK PKWY, USE THE LEFT TWO LANES TO TURN LEFT ONTO LEARY WAY, USE THE MIDDLE TWO LANES TO TAKE
THE RAMP ONTO WA-520 W, MERGE ONTO WA-520 W, TAKE 1-405 S EXIT TOWARDS RENTON. MERGE ONTO 1-405 S,
KEEP LEFT TO STAY ON 1-405 S, TAKE THE 1-5 S EXIT TOWARDS PORTLAND, MERGE ONTO 1-5 S. USE THE RIGHT
TWO LANES TO TAKE EXIT 143 TO MERGE ONTO S 320th ST TOWARDS FEDERAL WAY, MERGE ONTO S 320th (PASS
STARBUCKS ON YOUR RIGHT), TURN RIGHT AFTER BIGF00T JAVA (ON YOUR LEFT). CONTINUE STRAIGHT TO STAY ON
47th AVE SW, TURN RIGHT ONTO SW DASH POINT RD, DESTINATION WILL BE ON YOUR RIGHT.
� `•.Q: Ali, 9 s
SITE
SCALING DRAWINGS
SUBCONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & CONDITIONS ON THE
JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES
BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME.
IF USING 11"x17. PLOT. DRAWINGS -WILL 6E AT HALF SCALE -
DIG INFORMATION
911 UULC:
UTILITIES UNDERGROUND LOCATION CENTER
1-800-424-5555 OR 811
W W W.CALLBEFOREYOU DIG.ORG/WASHINGTON
Know what's below. 3 WORKING DAYS UTILITY NOTIFICATION PRIOR TO CONSTRUCTION
Call before you dig
BUILDING CODES AND STANDARDS
SUBCONTRACTORS WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND
LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE
LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE
DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN.
BUILDING CODE:
[INTERNATIONAL BUILDING CODE (IBC), 2016 AS ADOPTED BY THE LOCAL JURISDICTION]
ELECTRICAL CODE:
[NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 — 2015, NATIONAL ELECTRICAL CODE,
AS ADOPTED BY THE LOCAL JURISDICTION]
LIGHTNING PROTECTION CODE:
[NFPA 780 — 2002, LIGHTNING PROTECTION CODE]
SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING
STANDARDS.
AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF STEEL CONSTRUCTION,
ASD, THIRTEENTH EDITION
ANSI/TIA 222—G, STRUCTURAL STANDARDS FOR ANTENNA SUPPORTING STRUCTURES AND
ANTENNAS.
TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING REQUIREMENTS FOR
TELECOMMUNICATIONS
INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 81, GUIDE FOR MEASURING
EARTH RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND
SYSTEM
IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND GROUNDING OF
ELECTRONIC EQUIPMENT
IEEE C2 NATIONAL ELECTRIC SAFETY CODE, LATEST VERSION
TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS
ANSI T1.311, FOR TELECOM — DC POWER SYSTEMS — TELECOM, ENVIRONMENTAL
PROTECTION
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING
MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE
REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL
REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.
JURISDICTIONAL APPROVAL
APPROVED
PLANNING
City of Federal Way
Dept. of Community DIVED
Permit # A040036&--M-AIS
By W J lam Gw d: JAN 2 8 2020
Date a -16 ot006 ray OE 5EnERALWAY
COMMUNITY DEVELOPMENT
*at&t
AT&T MOBILITY
RTC OUILDING 3
1,3221 NE 72 nJ WAY
REDMOND, WA 98052
e:eM asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREONF
506 SECOND AVE, SUITE 1533
SEATTLE. WA 98104
PROJECT NO: 1915LID52
DRAWN BY: AF.
CHECKED BY: LC.
ISUBMITTALS I
0 OEC 05/19 +WC FWFL co
SH
A 5{p 57 19 b5UE0 FOR REMEW' AF
T-E INFORMATION CC4 IELAO IN THIS 9ET QE
OOCLIMENR lSCLOSURE RYBY NATUaE
ANY LFiR OR DISCLOSURE DMAT
WHILT-I RELATE TO THE CLIEE— M NAMED
D IS
STRICTLY HISnE0.
A6E SEPL
`Asas+
•'
r
r �
r i
a ■
4*�+iserss4Y+•
DUMAS BAY
SSBS
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 9BO23
FA #: 1009267E
SHEET T+TLE
TITLE SHEET
SI-SET NUMBER
T-1
SPECIAL NOTES:
GENERAL NOTES:
1. THE CONTRACTOR SHALL NOTIFY TOWER NETWORK CARRIER OF ANY ERRORS,
OMISSIONS. OR WCONSISTENOLS AS THEY MAY BE DISCOVERED IN PLANS,
DOCUMENTS, NOTES, OR 'SPECIFICATIONS PRIOR TO STARTING CONSTRUCTION
INCLUDING, BUY NOT UNITED BY, DEJBDUTION. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR CORRECTING ANY ERROR. OMISSION, OR INCONSISTENCY
AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE
ATTENTION OF TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER
AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF
CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY TOWER NETWORK
CARRIER CONSTRUCTION PROJECT MANAGER.
2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT
THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING
THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE COMMENCEMENT OF
CONSTRUCTION, THE CONTRACTOR HAVING BEEN AWARDED THIS PROJECT
SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT
DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT
WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH
CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN
WRITING.
3. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR
PARTICIPATION IN BID WALK.
4. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE,
THIS SET OF DOCUMENTS IS INTENDED TO BE USED FOR DIAGRAMMATIC
PURPOSES ONLY, UNLESS NOTED OTHERWISE. THE GENERAL C(7AfFIA=R'S
SCOPE OF WORK SHALL INCLUDE FURWSHIIN ALL MATERIALS, EOUIP►IE$R,
LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT
AS DESCRIBED IN THE DRAWINGS AND OWNER'S PROJECT MANUAL
5. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN
THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF
WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT
MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS
SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND
IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE
BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE
ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO
SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES
THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK,
UNLESS DIRECTED OTHERWISE.
6. DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCE. TOWER
NETWORK CARRIER IS NOT RESPONSIBLE FOR ANY ERRORS RESULTING FROM
THIS PRACTICE WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN
ON PLANS.
7. OWNER. CONTRACTOR, AND TOWER NETWORK CARRIER CONSTRUCTION PROJECT
MANAGER SHALL MEET JOINTLY TO VERIFY ALL DRAWINGS AND SPECIFICATIONS
PRIOR TO THE START OF CONSTRUCTION.
& THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO
PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT
CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
9. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED
HOURS TO AVOID DISTURBING NORMAL BUSINESS.
10. THE CONTRACTOR SHALL PROVIDE TOWER NETWORK CARRIER PROPER
INSURANCE CERTIFICATES NAMING TOWER NETWORK CARRIER AS ADDITIONAL
INSURED, AND TOWER NETWORK CARRIER PROOF OF UCENSE(S) AND PE &
PD INSURANCE.
11. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN
THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE
WORK UNDER THE CONTRACT.
12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING
TO MANUFACTURER'S/VENOOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE
OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE.
13. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL
BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND
ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL
LAWS, OROINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY
PUBLIC AUTHORITY, MUN[CJPAL AND UTILITY COMPANY SPECIFICATTDHS, AND
LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF
THE WORK.
14. GENERAL CONTRACTOR SHALL PROVIDE, AT THE PROJECT SITE, A FULL SET
OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND
ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH
THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE
TITLE SHEET IS STAMPED "FOR CONSTRUCTION" AND EACH SUCCESSIVE SHEET
BEARS THE ARCHITECT'S SIGNED WET STAMP.
15. A COPY OF GOVERNING AGENCY APPROVED PLANS SHALL BE KEPT IN A
PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW, SHALL BE
AVAILABLE FOR INSPECTION AT ALL TIMES. THE PLANS ARE NOT TO BE USED
BY THE WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME
INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR
SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION, COMPLETE
WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT
ALL TIMES UNDER THE DIRECT CARE OF THE SUPERINTENDENT. THE
CONTRACTOR SHALL SUPPLY TOWER NETWORK CARRIER CONSTRUCTION
PROJECT MANAGER. WITH A COPY OF ALL REVISIONS, ADDENDA, AND/OR
CHANGE ORDERS AT THE CONCLUSION OF THE WORK AS A PART OF THE
AS -BUILT DRAWING RECORDS.
16. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES
ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED
OTHERWISE.
17. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL, MECHANICAL,
AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS, NOTES,
DIMENSIONS, AND ALL REQUIREMENTS PRIOR TO THE START OF ANY WORK.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF
THE PROJECT AND SITE WHILE THE WORK IS IN PROGRESS UNTIL THE JOB IS
COMPLETE.
19. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING
UTILITIES WHETHER OR NOT SHOWN ON THE PLANS, AND TO PROTECT THEM
FROM DAMAGE. THE CONTRACTOR, OR SUBCONTRACTOR AS SPECIFIED IN THE
AGREEMENT BETWEEN SUBCONTRACTOR AND CONTRACTOR, SHALL BEAR THE
EXPENSES OF REPAIR AND/OR REPLACEMENT OF UTILITIES OR OTHER
PROPERTY DAMAGE BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF
THE WORK.
20. THE REFERENCES ON THE DRAWINGS ARE FOR CONVENIENCE ONLY AND
SHALL NOT LIMIT THE APPLICATION OF ANY DRAWING OR DETAIL
21. ALL DIMENSIONS ON THE PLANS ARE TO FACE OF STUD (F.O.S.) UNLESS
NOTED OTHERWISE (U,N.O.).
22. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE
REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL
BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS:
A. PROPERTY NOTED TO BE RETURNED TO THE OWNER.
B. PROPERTY NOTED TO BE REMOVED BY THE OWNER.
23. THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS
SHALL PROVIDE THE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES,
MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT. TRADE
STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING
OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION.
24. WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY
DISTRIBUTED OVER ROUGH FRAMED FLOORS OR ROOFS SO AS NOT TO
EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY
SHORING AND/OR BRACING IS TO BE PROVIDED WHERE THE STRUCTURE HAS
NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT.
25. PRIOR TO THE POURING OF ANY NEW SLAB OVER AN EXISTING SLAB THE
CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, CHASES, AND
EQUIPMENT WHICH ARE TO BE IMPLEMENTED INTO THE NEW WORK. ALL
ITEMS DESIGNATED TO BE ABANDONED SHALL BE NOTED AND DISCUSSED
WITH THE OWNER AND TOWER NETWORK CARRIER CONSTRUCTION PROJECT
MANAGER AS PART OF THE AS -BUILT DRAWING PACKAGE.
26. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR
FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND
OR PROJECT SITE.
27, BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE
NOTIFIED PRIOR TO ANY GRADING, CONSTRUCTION, AND ANY OTHER PROJECT
EFFORT AS MANDATED BY THE GOVERNING AGENCY.
28. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF
NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO
ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION.
29. THE PROJECT, WHEN COMPLETED, SHALL COMPLY WITH LOCAL SECURITY
CODES AND TITLE-24 ENERGY CONSERVATION REQUIREMENTS. (TITLE-24
WHEN APPUCABLE)
30. ALL GLASS AND GLAZING IS TO COMPLY WITH CHAPTER 54 OF THE U.S.
CONSUMER SAFETY COMMISSION - SAFETY STANDARDS FOR ARCHITECTURAL
GLAZING MATERIALS (42 FIR 1420, CFR PART 1201) AND LOCAL SECURITY
REQUIREMENTS,
31. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION.
UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT
MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
32. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE
DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH.
CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON
THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION
AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE.
33. NEW CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL MATCH IN
FORM, TEXTURE, FINISH, AND IN MATERIALS EXCEPT AS NOTED IN THE PLANS
AND SPECIFICATIONS.
34, THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING,
AND/OR SLEEVES REQUIRED FOR THE INSTALLATION OF FIXTURES,
MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS TO
ENSURE A PROPER AND COMPLETE JOB.
35. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A PROJECT LEVEL,
STRAIGHT, AND TRUE ACCORDING TO THE PLANS. THE CONTRACTOR SHALL
COMPARE THE LINES AND LEVELS OF THE EXISTING CONDITIONS WITH THOSE
SHOWN ON THE PLANS PRIOR TO THE START OF ANY CONSTRUCTION. TOWER
NETWORK CARRIER SHALL BE NOTIFIED OF ANY ERRORS, OMISSIONS, OR
INCONSISTENCIES PRIOR TO ANY CONSTRUCTION,
36. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES
FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE
GOVERNING AGENCIES.
37. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS
AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY
RESPONSIBLE FOR RECORDING THE RESULTS.
38. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS
AND SHALL NOT DO SO ON PUBLIC PROPERTY WITHOUT A PERMIT TO DO
SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE.
39. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS
TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN
OTHERWISE.
40. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN
CUTTING, FITTING, PATCHING, ETC., SO AS TO BE RECEIVED PROPERLY BY
THE WORK OF OTHER TRADES.
41. ALL DEBRIS AND REFUSE IS TO BE REMOVED FROM THE PROJECT PREMISES
AND SHALL BE LEFT IN A CLEAN (BROOM FINISH) CONDITION AT ALL TIMES
BY EACH TRADE AS THEY PERFORM THEIR OWN PORTION OF THE WORK.
42. TOWER NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES,
AND/OR ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER.
GUARANTEE OR WARRANTY THAT MAY BE IN EFFECT IS DONE SO THROUGH
THE COMPANY OR MANUFACTURER PROVIDING THE PRODUCT, FIXTURE,
AND/OR EQUIPMENT ONLY: UNLESS SPECIFIC RESPONSIBILITY IS ALSO
PROVIDED BY THE CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM.
43. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA
AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE, CONTACT THE
ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO
CONSTRUCTION. 1-800-424-5555.
44, CONTRACTOR TO REPLACE AND/OR REROUTE ANY EXISTING UNDERGROUND
UTILITIES ENCOUNTERED DURING TRENCHING AND GENERAL CONSTRUCTION.
45. CONTRACTOR TO LOCATE ALL UTILITIES PRIOR TO PLACEMENT OF MONOPOLE
FOOTING AND OTHER STRUCTURES TO BE PLACED IN GROUND. SEE GENERAL
NOTE #6 ON THIS SHEET.
46. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION.
47. CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND
SUBMIT TO TOWER NETWORK CARRIER ALONG WITH REDLINED CONSTRUCTION
SET.
48. CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING
UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE
RECLINED SET TO TOWER NETWORK CARRIER UPON COMPLETION.
P REQUIRED. 49. WITH POWER COMPANY AS REQ CONTRACTOR TO REPORT POWER
INSTALLATION COORDINATION SOLUTION(S) TO NETWORK CARRIER
REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT.
50. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED
BY TOWER NETWORK CARRIER CONSTRUCTION MANAGER.
51. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY
All FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS. DAMAGED GOODS,
ANO/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS
COMPETE AND ACCEPTED UNDER THIS CONTRACT; UNLESS NOTED OTHERWISE
IN THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR.
(DICEPTION) THE ROOFINGAGRWMENTNT FOR ALL WORKSUBCONTRACTOR CE,DON OSIGNEDSBYLTHE GENERAL CONTRACTOR,
TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF
TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF
THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN THE
OWNER AND THE CONTRACTOR.
52. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY
OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE
CONSTRUCTION OF THE PROJECT.
53. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS
AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT.
BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS
REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT AND MAKE FINAL
PAYMENT FOR SAID DOCUMENT.
54. THE ARCHITECT/ENGINEER IN CHARGE SHALL SIGN AND SEAL ALL DRAWINGS
AND/OR SPECIFICATIONS.
55, TOWER NETWORK CARRIER WILL REVIEW AND APPROVE SHOP DRAWINGS AND
SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT. TOWER NETWORK
CARRIER PROJECT APPROVAL OF A SEPARATE ITEM SHALL NOT INCLUDE
APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS.
56. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY
TOWER NETWORK CARRIER COMMUNICATIONS.
57. CONTRACTOR TO PROVIDE TRENCH AS REQUIRED TO INSTALL BOTH
ELECTRICAL AND TELEPHONE UNDERGROUND CONDUITS (#40 PVC) PER S.C.E.
WORKORDER. BACKFILL WITH CLEAN SAND AND COMPACT TO THE
SATISFACTION OF THE DISTRICTS INSPECTOR. REPLACE FINISH GRADE WITH
MATCHING MATERIALS (GRASS, ASPHALT, CONCRETE, ETC.)
58. CONTRACTOR TO PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR
SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY
EQUIPMENT UTILIZED DURING CONSTRUCTION.
59. CONTRACTOR TO PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE
CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND
MAINTAIN EXISTING SURFACE DRAINAGE SLOPES.
60. CONTRACTOR TO REPLACE LANDSCAPE VEGETATION THAT WAS DAMAGED DUE
TO CONSTRUCTION, AND TO MODIFY REMAINING IRRIGATION LINES TO
OPERATING CONDITION, PROVIDING FULL COVERAGE TO IMPACTED AREAS.
61. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE
GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND
BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH,
REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK
GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE
PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY.
62. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS
WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE
GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP
DESIGNER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS
SIMULATING (IN APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING
FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL
FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP
CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE PROVIDED, THE CONTRACTOR
SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED
IN PHOTOSIMULATION. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL
CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO
FABRICATION AND CONSTRUCTION.
63. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED,
CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING
CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST
TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN
UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING AS -BUILT
DRAWING SET" - HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF
REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST
TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE
PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL
PENETRATION AREAS WHERE ANCHORING OCCURS.
64. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING
TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS
(WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE
ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE
SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP
UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC.
65. ALL WORK TO BE DONE BETWEEN HOURS OF 8:00 AM AND 5:00 PM,
EXCLUDING HOLIDAYS
PLANS PART OF THIS SET ARE COMPLEMENTARY, INFORMATION IS NOT LIMITED TO ONE PLAN.
DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF
THE ARCHTECT, WHETHER THE PROJECT FOR WHICH THEY ARE MACE IS EXECUTED OR NOT. THEY ARE
NOT To BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY
AOREEMEW IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. THESE PLANS WERE
PREPARED TO BE SUBMITTED TO GOVERNLt✓»NTAL BUILDING AUTHORITIES FOR REVIEW FOUR COMPLIANCE
WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO
BUILD ACCORDING TO APPUCABLE BUILDING CODES.
2. IF CONTRACTOR OR SUB -CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED
PLANS, THEN IT LS THE CONTRACTOR'S AND THE SUB -CONTRACTOR'S RCSPON5181LTTY TO PROVIDE THE
ARCHITECT WITH 4 COPIES OF THE PROPOSED CHANCES FOR HIS APPROVAL BEFORE PROCEEDING WITH
THE WORK. IN ADDITION THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR
PRCCU%NG ALL, NECESSARY APPROVALS FROM THE BUILDING AUTIIORRIES FOR THE PROPOSER CHANGES
BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE
RESPONSIBLE FOR PROCURING All NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING
AUTHORITIES DURING THE EXECUTION OF THE WORK.
3. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE
A MINIMUM ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR,
SUB -CONTRACTOR. AND/OR SUPPUER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB
WHEN Ai)f PONAL ITEMS ARE REQUIRED TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO
EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A COMPLETE. ADEQUATE AND SAFE WORKING
CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE DRAWINGS,
FOR EXAMPLE, IF AN JrEm ANC/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE SIZE (I,E.
ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED OVANTICY 01- STRUCTURAL ELEMENTS).
REDUCED SPACING. AND/OR INCREASED LENGTH (IF- BOLT LENGTHS, BAR LENGTHS) THEN IT SMM1LL BE
0EEME0 ARID UNDERSTOOD TO BE INCLVDED IN THE BID/PROPOSAL.. THESE DOCUMENTS ARE MEANT
AS A GUIDE AND ALL ITEMS REASONABLY INFERRED SHALL BE MEMED TO BE GICLUDED.
4. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A
CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR.
at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
fa COREONE
CONSULTING US:A
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
PROJECT NQ 1 915LK352
CRAWN BY: AF.
CHECKED BY: LC.
SUBMITTALS
J
V uw u�21n ,w..� v.., +,•LL
A SOP 17/I9 YT1R R(VIE1Y ,�
T1-E II�FOFi�AATILIN CgYTAINEO IN THIS SET q=
gxLrolsrts Is pao�aETARv Erc NP.TL�S
ANY UEtE OF gStLOSJRE OT1-TER TFI{1N THu.T
WHICH RELATES IO THE 0.1EM NAM® U^
STRICTLY PROHIEIITEQ
A6E SEAL
SITE
DUMAS BAY
SSB5
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 98023
FA #: 10092676
SHEETTRLE
GENERAL NOTES
SHEET nu�E1ER
GN-1
DESIGN CRITERIA:
1. THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE 2015 WITH WASHINGTON STATE BUILDING CODE
AMENDMENTS (2015 SEATTLE BUILDING CODE)
2. DESIGN LOADS:
SEE STRUCTURAL
CONCRETE NOTES:
1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318.
2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN
ACCORDANCE WITH CHAPTER 19 OF THE 2015 IBC. STRENGTHS AT 28 DAYS
AND MIX CRITERIA SHALL BE AS FOLLOWS..
TYPE OF CONSTRUCTION 28 DAY STRENGTHS W/C MINIMUM CEMENT
(f'c) RATIO CONTENT
A. STRUCTURAL SLABS AND
4,000 PSI
5.45
PER CUBIC YARD
6 Yz SACKS
CONCRETE PIERS
4,000 P51 5.45
4,000 PSI 545
.
D. SLABS ON CRADEMPPING SLABS 2.500 PSI 5.45 6 )¢ SACKS
(FOR ON
CABINET)
CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O.
3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE
METHODS AND PROCEDURES OF CONCRETE PLACEMENT.
4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE
AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260,
C494, C618, C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN
ACCORDANCE WITH TABLE 1904.2.1 OF THE 2015 IBC.
5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT
S1), GRADE 60, fy=60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO
NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy=40,000 PSI. GRADE 60
REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM
TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(SI) MAY BE
WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE
WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED.
6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN
ACCORDANCE WITH AC1 315 AND 318. LAP ALL CONTINUOUSREINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0".
PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP
CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". LAP
ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF B" AT SIDES AND
ENDS.
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185.
8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615,
GRADE 60, fy=60,000 PSI.
9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD
BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT.
10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS
FOLLOWS:
- FOOTINGS AND OTHER UNFORMED 3'
SURFACES, EARTH FACE
- FORMED SURFACES EXPOSED (#6 BARS OR
LARGER) 2"
TO EARTH OR WEATHER ($5 BARS OR SMALLER) 1 1/2"
- SLABS AND WALLS (INTERIOR FACE) 3/4"
11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOME BRICKS.
12. ANCHOR BOLTS TO CONFORM TO ASTM A307.
13. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER
AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S PUBUSHED RECOMMENDATIONS, GROUT STRENGTH SHALL
BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 PSI
MINIMUM).
14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE
TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER.
BUILDING NOTES:
1. VERIFICATION THAT THE EXISTING BUILDING ROOF CAN SUPPORT THE
PROPOSED ANTENNA LOADING IS TO BE DONE BY OTHERS.
2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF
ALL INITIAL AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE
SUPPORTED AND RESTRAINED AT THE CENTERS SUITABLE TO THE
MANUFACTURER'S REQUIREMENTS.
SAFETY PROGRAM:
1, CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING AND DOCUMENTING
THEIR OWN SAFETY TRAINING PROGRAM,
ABBREVIATED ROOF TOP SAFETY
PROCEDILRES WHEN APPLICABLE)-
(AS PER "ACCIDENT PREVENTION PROGRAM" - BY PERMISSION OF WREN
CONSTRUCTION, INC. - 03/01/99)
FALL PROTECTION METHODS AND EQUIPMENT
ROOF TOP INSTALLATIONS
1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF
EDGE, THE CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY
MONITOR TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION
WORKERS.
2. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E..
BACKING UP TOWARD A ROOF EDGE. ETC.) OR UNSAFE ACTIVITIES. THE
SAFETY MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUAL AND
VERBAL DISTANCE OF THE CONSTRUCTION WORKERS.
3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN
UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE.
4. SAFETY LINE SHALL BE MINIMUM Ye" DIAMETER NYLON, WITH A NOMINAL
TENSILE STRENGTH OF 5400 LBS.
5. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE
STRUCTURE.
ETY 6. SAFLINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO
REACH EDGE OF ROOF, BUT NOT BEYOND.
7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS.
8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION
EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES,
INCLUDING:
INSPECTION OF CONSTRUCTION AREA FOR HAZARDS
USE OF AN INSPECTION CHECKLIST
INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS
REPORTING AND DOCUMENTING ANY HAZARDS
REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION
POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN
RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER
COWORKER SAFETY REPRESENTATIVE
REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL
NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION
REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY TOWER
ERECTORS,
EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS
29 CFR 1926.500 - SCOPE, APPLICATION, AND DEFINITIONS
29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION
19 CFR 1926.502 - FALL PROTECTION SYSTEMS CRITERIA AND
PRACTICES
SPECIAL INSPECTIONS REQUIRED -
SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION
CONCRETE OVER 4000 PSI (Eh SACK MIX) AT 28 DAYS
CONCRETE PLACEMENT AT SLAB ON GRADE
WRITTEN CERTIFICATION FOR PROPER PLACEMENT OF
REINFORCEMENTS AT SLAB ON GRADE
FOUNDATION EXCAVATION AND FILL INCLUDING UTILITY TRENCHES
CERTIFICATION OF BUILDING PAD, FOUNDATION AND FILL BY
THE GEOTECHNICAL ENGINEER OF RECORD
❑ VERIFICATIONS OF MILL REPORT
❑ IDENTIFICATION OF STEEL AND AT JOB SITE
❑ ADHESIVE BOLTS IN CONCRETE OR MASONRY
❑ ANCHOR BOLTS INSTALLATION AND PLACEMENT IN
CONCRETE
❑ HIGH STRENGTH BOLTING
SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD,
WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED
SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH
THE DESIGN OF THE BUILDING. THE DEFERRED AND SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND
SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL
❑ SPRAYED -ON- FIREPROOFING
❑ STRUCTURAL MASONRY
❑ PRESTRESSED CONCRETE
❑ ALL FIELD WELDING
❑ REINFORCING PLACEMENT
❑ DESIGNER SPECIFIED (SEE SHEET_)
❑ OTHER _..T
*at&t
AT&T MOBILITY
FTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 93052
•:•M asTec
Network Solutions
22263 681h AVE S
KEIJT, WA 98032
COREONE
CONSULT
506 SECOND AVE, SUITE 1533
SEATTLE, WA 93104
PROJECT NO: 191 SL1C52
OFIAVVN BY: A F.
CHECKED BY: L.C.
SUBMITTALS
TI£ Irrow,nnnoN canrrAlNeo w Trns ssr of
pCC1M3YT"" IS PRCRTIE7ARY BY NLATL.AiE
Ann use oR ^= rae oTrlsa THAN THAT
W Hldi RELgTES TO THE CUETfT NAM® IS
STRICTLY PPl]HIBREC
A6E cse,
sITE
DUMAS BAY
SS65
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 96023
FA #: 10052676
sl-o=ET TTTLe
GENERAL NOTES II
SHEET NJMBEA
GN-2
GENERAL NOTES:
1. THESE DOCUMENTS WERE DESIGNED IN ACCORDANCE WITH THE LATEST
VERSION OF APPLICABLE LOCAL/STATE/COUNTY/CITY BUILDING CODES, AS
WELL AS ANSI/TIA-222 STANDARD. AWWA-D100 STANDARD, NDS, NEC, MSJC,
AND/OR THE LATEST VERSION OF THE INTERNATIONAL BUILDING CODE,
UNLESS NOTED OTHERWISE IN THE CORRESPONDING STRUCTURAL REPORT.
2. ALL CONSTRUCTION METHODS SHOULD FOLLOW STANDARDS OF GOOD
CONSTRUCTION PRACTICE.
3. ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY
QUALIFIED CONTRACTORS EXPERIENCED IN SIMILAR CONSTRUCTION.
4. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS. IF OBSTRUCTIONS
ARE FOUND, CONTRACTOR SHALL NOTIFY ENGINEER OF RECORD PRIOR TO
CONTINUING WORK.
5. ANY CHANGES OR ADDITIONS MUST CONFORM TO THE REQUIREMENTS OF
THESE NOTES AND SPECIFICATIONS, AND SHOULD BE SIMILAR TO THOSE
SHOWN. ALL CHANGES OR ADDITIONS SHALL BE SUBMITTED TO THE ENGINEER
OF RECORD FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND/OR
CONSTRUCTION.
6. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL
MISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS, ETC. NECESSARY
TO PROVIDE A COMPLETE AND STABLE STRUCTURE DURING CONSTRUCTION.
TIA-1019-A-2011 IS AN APPROPRIATE REFERENCE FOR THOSE DESIGNS
MEETING TIA STANDARDS. THE ENGINEER OF RECORD MAY PROVIDE FORMAL
RIGGING PLANS AT THE REQUEST AND EXPENSE OF THE CONTRACTOR.
7. INSTALLATION SHALL NOT INTERFERE NOR DENY ADEQUATE ACCESS TO OR
FROM ANY EXISTING OR PROPOSED OPERATIONAL AND SAFETY EQUIPMENT.
B. CONTRACTOR SHALL FIELD VERIFY EXISTING FIELD CONDITIONS AND ALL
DIMENSIONS PRIOR TO ANY FABRICATION OR MODIFICATION. CONTACT CORE
ONE CONSULTING IF ANY DISCREPANCIES EXIST.
STEEL CONSTRUCTION NOTES:
1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC MANUAL OF STEEL
CONSTRUCTION 14TH EDITION, FOR THE DESIGN AND FABRICATION OF STEEL
COMPONENTS.
2. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES, AND GROUND SURFACES
WHERE EXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE
REPAIRED WITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING
COMPOUND PER ASTM A780 AND MANUFACTURERS' RECOMMENDATIONS.
3. ALL FIELD DRILLED HOLES TO BE USED FOR FIELD BOLTING INSTALLATION
SHALL BE STANDARD HOLES, AS DEFINED BY AISC. UNLESS NOTED
OTHERWISE.
4. ALL EXTERIOR STEEL WORK SHALL BE GALVANIZED IN ACCORDANCE WITH
ASTM A123.
5. ALL STEEL MEMBERS AND CONNECTIONS SHALL MEET THE FOLLOWING GRADES:
• ANGLES, CHANNELS, PLATES AND BARS TO BE A36. Fy=36 KSI,
U.N.O.
• W SHAPES TO BE A992. Fy=50 KSI, U.N.O.
• RECTANGULAR HSS TO BE A500, GRADE B. FY=46 KSI. U.N.O.
• ROUND HSS TO BE A500, GRADE B. FY=42 KSI, U.N.O.
• STEEL PIPE TO BE A53, GRADE B. Fy=35 KSI, U.N.O.
• BOLTS TO BE A325-X. Fu=120 KSI, U.N.O.
• U-BOLTS AND LAG SCREWS TO BE A307 GR A. Fu=60 KSI, U.N.O.
6. ALL WELDING SHALL BE DONE USING E80XX ELECTRODES, U.N.O.
7. ALL WELDING SHALL CONFORM TO AISC AND AWS D1.1 LATEST EDITION.
8. ALL HILTI ANCHORS TO BE CARBON STEEL, U.N.O.
• MECHANICAL ANCHORS: KWIK BOLT-TZ, U.N.O.
CMU BLOCK ANCHORS: ADHESIVE - HY120, U.N.O.
• CONCRETE ANCHORS: ADHESIVE - HY150, U.N.O.
• CONCRETE REBAR: ADHESIVE - RE500, U.N.O.
9. ALL STUDS TO BE NELSON CAPACITOR DISCHARGE 1/4"-20 LOW CARBON
STEEL COPPER -FLASH AT 55 KSI ULT/50 KSI YIELD, U.N.O.
10. BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT' CONDITION AS DEFINED BY
ASO.
11. MINIMUM EDGE DISTANCES SHALL CONFORM TO AISC TABLE J3.4.
CONCRETE CONSTRUCTION NOTES:
1. CONCRETE TO BE 4000 PSI 0 28 DAYS. REINFORCING BAR TO CONFORM TO
ASTM A615 GRADE 60 SPECIFICATIONS. CONCRETE INSTALLATION TO CONFORM
TO ACI-318 BUILDING REQUIREMENTS FOR REINFORCED CONCRETE. ALL
CONCRETE TO BE PLACED AGAINST UNDISTURBED EARTH FREE OF WATER AND
ALL FOREIGN OBJECTS AND MATERIALS. A MINIMUM OF THREE INCHES OF
CONCRETE SHALL COVER ALL REINFORCEMENT. WELDING OF REBAR IS NOT
PERMITTED.
2. EXISTING CONCRETE SURFACES THAT ARE TO BE IN CONTACT WITH NEW
PROPOSED CONCRETE SHOULD BE WIRE BRUSHED CLEAN AND TREATED WITH
APPROPRIATE MECHANICAL SCRATCH COAT AND REPAIR MATERIALS OR
APPROPRIATE CHEMICAL METHODS SUCH AS THE APPLICATION OF A BONDING
AGENT, EX. SAKRETE OR EQUIVALENT, TO ENSURE A QUALITY BOND BETWEEN
EXISTING AND PROPOSED CONCRETE SURFACES -
FIBER REINFORCED POLYMER (FRP) NOTES
1. FRP PLATES, SHAPES, BOLTS AND NUTS (STUD/NUT ASSEMBLIES) SHALL CONFORM TO
ASTM 0638, 695, 790. PLATES AND SHAPES TO BE FY = 30 KSI (LW), 7 KSI (CW) MIN.
2. IF FIELD FABRICATION IS REQUIRED, ALL CUT EDGES AND DRILLED HOLES TO BE SEALED
USING VINYL ESTER SEALING KIT SUPPLIED BY THE MANUFACTURER.
3. ALL FASTENERS TO BE 1/2' DIA FRP THREADED ROD WITH FIBER REINFORCED
THERMOPLASTIC NUT, SPACED AT 12 INCHES ON CENTER MAXIMUM, U.N.O., FOR PANELS
AND AS DESIGNED FOR STRUCTURAL MEMBERS.
4, THE COLOR AND SURFACE PATTERN OF EXPOSED FRP PANELS SHALL MATCH THE EXTERIOR
OF THE EXISTING BUILDING, U.N.O.
5 STUD/NUT ASSEMBUES SHOULD BE LUBRICATED FOR INSTALLATION
6. ENSURE BEARING SURFACES OF THE NUTS ARE PARALLEL TO THE SURFACES BEING
FASTENED.
7- TORQUE BOLTS ACCORDING TO THE FOLLOWING TABLE:
INSTALLATION TORQUE TABLE
ys
unueroimnc
Mi= lOMOE
P
VJ�awc
Ie n-ua
art-las
e/0-II 1•R
]5 IIHBs
le rt-IB]
]/�t0 uC
50 rt�85
N iT-I�
I-0 ANC
10 1-
8. WHEN TIGHTENING FRP STUD/NUT ASSEMBUES, WRENCHES MUST MAKE FULL CONTACT WITH
ALL NUT EDGES A STANDARD SIX POINT SOCKET IS RECOMMENDED.
9. STUD/NUT ASSEMBLIES SHOULD BE BONDED BY APPLYING BONDING AGENT TO ENTIRE NUT
AND EXPOSED STUD.
10. ALL FRP MATERIALS TO BE PROVIDED BY FlBERGRATE COMPOSITE STRUCTURES, DALLAS TX,
OR APPROVED EQUAL
11. ALL FRP SHAPES TO BE DYNAFORM PULTRUDED STRUCTURAL SHAPES.
12. ALL FRP PLATES TO BE FlBERPLATE MOLDED FRP PLATE-
13. ALL FRP PANELS TO BE FIBERPLATE CLADDING PANEL.
14. EACH FRP PANEL TO BE IDENTIFIED WITH LARR125536 AND FIBERGRATE COMPOSITE
STRUCTURAL LABEL
15. FRP MATERIAL TO BE CLASSIFIED AS CC1 OR BETTER, AND HAVE MAXIMUM FLAME
SPREAD OF 50.
16. ALL DESIGN AND CONSTRUCTION TO BE COMPLETED IN ACCORDANCE WITH LOS ANGELES
RESEARCH REPORT RR25536, DATED FEBRUARY 1, 2016.
17. SPECIAL INSPECTIONS MUST BE PROVIDED FOR ALL FRP INSTALLMENTS. SEE SPECIAL
INSPECTION SECTION, THIS SHEET.
RATIO OF EDGE DISTANCE TO FRP FASTENER DIAMETER
xucc
]cw•eoom
mx wseulx - n• enT ro ao
]aae
]o
n• nr„•n
Is-]]
]s
Iw •aN-o•an•
.o-xo
WOOD CION5TRUCTION NOTES:
1. ALL EXISTING WOOD SHAPES ARE ASSUMED TO BE DOUGLAS FIR -LARCH WITH A REFERENCE
DESIGN BENDING VALUE OF 1000 PSI MIN.
2. ALL PROPOSED WOOD SHAPES ARE TO BE DOUGLAS FR-LARCH WITH A REFERENCE DESIGN
BENDING VALUE OF 1000 PSI MIN. U.N.O.
3. ALL EXISTING AND PROPOSED GLUED LAMINATED TIMBERS ARE TO BE 24F-1.8C DOUGLAS
FIR BALANCED WITH A REFERENCE DESIGN BENDING VALUE OF 2400 PSI MIN U.N.O.
MASONRY CONSTRUCTION NOTES:
1. ALL BRICK TO BE 1500 PSI MIN. REINFORCING BAR (IF APPLICABLE) TO CONFORM TO
ASIM A615 GRADE 60 SPECIFICATIONS. ALL MORTAR TO BE 2000 PSI MIN.
• FOR INTERIOR/ABOVE GRADE APPLICATIONS TYPE N MORTAR HAVING MINIMUM
MODULUS OF RUPTURE OF 100 PSI SHALL BE USED. FOR EXTERIOR/BELOW
GRADE APPLICATIONS TYPE M OR S MORTAR HAVING A MINIMUM MODULUS OF
RUPTURE OF 133 PSI.
• BRICK AND MORTAR INSTALLATION TO CONFORM TO MSJC BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES.
2. ALL CMU TO BE 1500 PSI MIN. REINFORCING BAR (IF APPLICABLE) TO CONFORM TO ASTM
A615 GRADE 60 SPECIFICATIONS. ALL MORTAR TO BE 20DO PSI MIN.
• FOR INTERIOR/ABOVE GRADE APPLICATIONS, TYPE N MORTAR HAVING MINIMUM
MODULUS OF RUPTURE OF 64 PSI SHALL BE USED FOR UNGROUTED BLOCKS,
AND 158 PSI FOR FULLY GROUTED BLOCKS.
• FOR EXTERIOR/BELOW GRADE APPLICATIONS TYPE M OR S MORTAR HAVING A
MINIMUM MODULUS OF RUPTURE OF 84 PSI SHALL BE USED FOR UNGROUTED
BLOCKS, AND 163 PSI FOR FULLY GROUTED BLOCKS.
• BRICK AND MORTAR INSTALLATION TO CONFORM TO MSJC BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES.
TOWER PLUMB & TENSION NOTES:
1. PLUMB AND TENSION TOWER UPON COMPLETION OF STRUCTURAL MODIFICATIONS
DETAILED IN THESE DRAWINGS.
2. RETENSIONING OF EXISTING GUY WIRES SHALL BE PERFORMED AT A TIME WHEN THE
WIND VELOCITY IS LESS THAN 10 MPH AT GROUND LEVEL AND WITH NO ICE ON THE
STRUCTURE AND GUY WIRES.
3. PLUMB THE TOWER WHILE RETENSIONING THE EXISTING GUY WIRES. THE HORIZONTAL
DISTANCE BETWEEN THE VERTICAL CENTERUNES AT ANY TWO ELEVATIONS SHALL NOT
EXCEED 0.25% OF THE VERTICAL DISTANCE BETWEEN TWO ELEVATIONS FOR LATTICED
STRUCTURES.
4. THE TWIST BETWEEN ANY TWO ELEVATIONS THROUGHOUT THE HEIGHT OF A LATTICE
STRUCTURE SHALL NOT EXCEED 0.5 DEGREES IN 10 FEET. THE MAXIMUM TWIST OVER
THE LATTICE STRUCTURE HEIGHT SHALL NOT EXCEED 5 DEGREES.
SPECIAL INSPECTIONS NOTES:
I. A QUALIFIED INDEPENDENT TESTING LABORATORY, EMPLOYED BY THE OWNER AND
APPROVED BY THE JURISDICTION, SHALL PERFORM INSPECTION AND TESTING IN
ACCORDANCE WITH THE THE GOVERNING BUILDING CODE, APPUCABLE SECTION(S) AS
REQUIRED BY PROJECT SPECIFICATIONS FOR THE FOLLOWING CONSTRUCTION WORK:
u. STRUCTURAL WELDING (CONTINUOUS INSPECTION OF FIELD WELDS ONLY).
b, HIGH STRENGTH BOLTS (PERIODIC INSPECTION OF A325 AND/OR A490 BOLTS)
TO BE TIGHTENED PER'TURN-OF-THE-NUT' METHOD.
c. MECHANICAL AND EPDXIED ANCHORAGES.
d. FIBER REINFORCED POLYMER.
• THE SPECIAL INSPECTOR MUST VERIFY THAT THE FRP MATERIAL SPECIFIED
ON THE APPROVED DESIGN DOCUMENTS IS BEING INSTALLED.
• THE SPECIAL INSPECTOR MUST VERIFY THAT ALL CUT EDGES AND DRILLED
HOLES ARE PROPERLY SEALED USING A VINYL ESTER SEALING KIT SUPPLIED
BY THE MANUFACTURER.
• THE SPECIAL INSPECTOR MUST VERIFY THAT THE STRUCTURE IS BUILT IN
ACCORDANCE WITH THE APPROVED DESIGN DOCUMENTS.
2 THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS TO THE
BUILDING DEPARTMENT, THE ENGINEER OF RECORD, AND THE OWNER UNLESS THE
FABRICATOR IS APPROVED BY THE BUILDING OFFICIAL TO PERFORM WORK WITHOUT THE
SPECIAL INSPECTIONS,
MAXIMUM ALLOWABLE ANGLE CLIP:
DESIGN CRITERIA:
A- SECTOR FRAMES 250 LB LIVE LOAD
PLATFORMS 500 LB LIVE LOAD
ASSUMED SOIL BEARING PRESSURE = 1,500 PSF
B- WIND DESIGN DATA:
RISK CATEGORY = II
WIND SPEED = 97 MPH (3-SECOND GUST)
WIND IMPORTANCE FACTOR 1 = 1.00
WIND EXPOSURE = C
ICE LOADING = 30 WIN W/ 1- ICE THICKNESS
DESIGN WIND PRESSURE FOR TOWER EQUIPMENT - 30.58 PSF
C- 9ESMIC DESIGN DATA:
SEISMIC IMPORTANCE FACTOR I = 1.00
RISK CATEGORY = II
MAPPED SPECTRAL RESPONSE ACC, Ss = 1.372 g & S1 = 0.472 g
SITE CUSS = D
SPECTRAL RESPONSE COEFFICIENTS, SOS = 0.915 & SDI = 0.575
SEISMIC DESIGN CATEGORY = D
BASIC SI791C-FORCE RESISTING SYSTEM = EQUIPMENT
RESPONSE MODIFICATIONS FACTOR R = 25
DESIGN RASE SHEAR = CAW
SEISMIC RESPONSE COEFFICIENT Cs = 0.439
ANALYSIS PROCEDURE USED: NON STRUCTURAL COMPONENTS (CHAPTER 13)
*at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT. WA 98032
13 CCOORLEONE
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
F]RQJECT Na. 19151J052
DRAWN BY: A
CHECKED BY. LC,
SUBMITTALS
T}£ IFOPIAAT1pN CCMAINEp IN TH19 BET OF
OOCUNISJP" IS FSBOPPBETARY BY NATLFTE
ANY USE OR CISCLO"JJRE OTHER THAN THAT
WHICH RELATES TO THE CLIENT NAMED IS
BTRCTLY PRCHIBI" E0.
fy�rr,+
f F
■ A
;
"y 41l+�4ssifyi
SITE
DUMAS BAY
SS65
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA BB023
FA *: 10092676
SHEET TRLE
GENERAL NOTES III
SHEET NLev1BER
GN-3
I'
1
NOTES:
b,, �•,•, 1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
S(••'• y' ,� N• J a6 . PACIFIC TELECOM SERVICES DATED 12/07/2011.
9�
I - . F ANION".. •� I r 2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
�i • �L _ •..� a• yam• • + .Y '''' • �? ' +, CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
nr • �`i • '0' j 3+�"� I DISCREPANCIES TO THE ENGINEER.
TRUE NORTH ARROW SHOWN ON`,U:' Y f :�.^; �y° a'•
THIS DRAWING IS APPROXIMATE `4,, • �6r.!• ' L.; k - I xL,+.,•.•� •,•pcx �.P
ONLY AND MUST BE VERIFIED
rS er. •,�pL: r? L I srs°ry4iln" y�s5 a�L+ .sa.
� � it r ?�• "�• �Y �r.4• n'' r•1c, I y 4Q
PARCEL #218 .00.. I �" `,�• - L ae
.� 15 LOT 8�,��,.
yL /•;f f'"h a
•9J •�4ia:y6O `I r I��
• �q r, .' �� S.W_ 313th ROAD
,� s, •�' - I PARCEL #2116500070 _
� ; .�` .r • ,'t.'��� LOT 7 �•
ti f. _ f S; LEXISTING
•' .9�i` • -� BUILDING 7%
�•tslA , � � , �" J
PARCEL 12116500090 • -- _ r i /
L EXISTING
• s g. r / y7 c} j�a BUILDING
-. • �v.`�.,;• + tyl c /EXISTING / / r !�I {• 7
/
o'a . • : - ib-_ BUILi:]NG� - L EXISTING i/
APPROXIMATE LOCATION OF �p - 7 BUILDING -
EXISTING PROPERTY LINE. TYP. gR4, �" / r
y
cr • " n n \ •� I;r 3r'.af , o!V ��.QiF
� dr Ie � .as eiS{ W ts•. .ine'i�;n.`' #,'. +��-.�- �f .,, o�•�.
I •,r5.. `r • V•�- w�`I "''-Y- A. �v ac •r''d'" + ), 4.7,L� .}.
as J� a'a"`� . ,¢^`�"o� a�•io-. �r 41
—Z� ` � '- ter . o f o a— oxa
af•
EXISTING
OVERHEAD R LINE, TYP.POWERWE% L
/ C-S C-5
S.W. DASH POINT ROAD
1 A P V E0
PLANNINIO
PARCEL #1121039063
City of Federal iWay
Dept. of Community I� VeI pment
Permit# o`�d-IDP3laf�-0�-�
By W i l\ � aM Girt WN - r SITE PLAN
Date - `o` - V 17.0 - 0
..; 10, 20' ,,.40L
at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
':•M asTec
Network Solutions
22263 68th AVE S
KENT. WA 98032
■ COREONE
COINSULTIINC tJSA.
506 SECOND AVE, SUITE 15.33
SEATTLE, WA 98104
PROJECT NO: 191 5LID52
DRAWN BY: AF.
CHECKED BY: LC
F_ SUBMITTALS I
TFE IhFORIVU�TIONG AINMINTHSSET�
OOCLIMcTrt5 is PROPRIETARY — NAT
--CPU PIE C__ THAN T T
WHICH RELATES TO TFIE dJEM NAMED IS
STRICTLY PP#IIEIfTED
OUMAS BAY
SS65
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
_WA 98023
FA *: 10092B76
SHEET TRLE
SITE PLAN
6HEET MJMBER
C-1
TRUE NORTH ARROW SHOWN ON
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERFIED
NOTES:
1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
PACIFIC TELECOM SERVICES DATED 12/07/2011.
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
I II 79 o \
I
a
I
l } II n
1 1 AT&T EQUIPMENT I — I V
C-3 C-4 COMPOUND ON GRADE y X
X X X
r i
I E71InNG AT&T UNDERGROUND CONDUIT
C/w (4) EXISTING 7/8' CABLES TO
k yj, i r EXISTING WOOD UTILV POLE
;�• � oryP }
L EXISTING
°�A I GRAVEL AREA?
\ ap
ory,
gyp\ oryp`
AT&T ANTENNA INSTALLATION:, \ qm\
/ry
REFER TO RF-1 AND RF-2
FOR EXISTING AND
PROPOSED ANTENNA LAYOUTS °"P\
EXISTING OVERHEAD
/POWER LINOS, I
APPROV D/j,-/
_
City of Federal Wad
Dept. of Community De)ielopment
Permit # a0-10036&-b&-At
gy OfA Cnold�n .
PARTIAL SITE PLAN
N
D
1
/
/
/
\
/
Watm
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72Dd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 681h AVE S
KENT, WA 98032
R COREONE
506 SECOND AVE, SUITE 1533
SEATTLE, WA 98104
PROJECTNQ 1915UD52
[DRAWN BY: AF•
CHECKED BY: L_C,
SUBMITTALS
I D I DEC 05/191 100% FINAL CD's I SNI
TfEINFORMATION CONTAINED IN T 15 EET
DOF
OCL_SIS PROPRIETARY BY NATLPE
ANY USE OR OIELLOSURE a-- T THAT
WHICH REl B TO THE CLIENT NAM® IS
STWCTLY PROHI&TEO
DUMAS BAY
SSB5
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 98023
FA *: 10092676
SI-SET TITLE
PARTIAL SITE PLAN
SFFFE NUMBER
C-2
TRUE NORTH ARROW SHOWN ON
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERIFIED
EXISTING WOOD FENCE
EXISTING P.T. RR —TIE
WOOD STEPS, TYP.
EXISTING
CHAINLINK FENCE
X — X — X — Y, — X — X — — ' - X — X — X — X
APPROVED
PLANNING
City of Federal Way
Dept. of Community Development
Permit #_-a10o3&&-00-Ab
Fay Isatln �aoic
Date a-1a-�o9c�
PAD
EXISTING AT&T ELECTRICAL
EXISTING AT&T B IN
ARGUS POWER
UMTS EQUIPMENT 1{ EQUIPMENT
CABINET CABINET
EXISTING AT&T F18ER JUNCTION
BOX MOUNTED TO H—FRAME
1
EXISTING AT&T BRU
EQUIPMENT CABINET
c/w (2) MARATHON
BATTERIES
jl.l111�1
EXISTING AT&T
RXAF EQUIPMENT
CABINET
/
EXISTING
GSM
AT&T
EQUIPMENT
/
CABINET
O
EXISTING
AT&T
PURCELL
EQUIPMENT
[llli�lll[ll[
.
lCCliil�C
4+
I
EXISTING
AT&T
�
TE43 EQUIPMENT
_1
CABINET
Ill�Jl�liCltllll i
NOTES:
1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
PACIFIC TELECOM SERVICES DATED 12/07/2011.
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
— X— X— X— X— X— X— X— X— X
r �
1I F r EXISTING CONCRETE RETAINING WALL
� r r
EXISTING AT&T UNDERGROUND CONDUIT
+ f f c/W (4) EXISTING 7/8" CABLES TO
�✓ EXISTING WOOD UTILITY POLE
�r
r �
� � r
r � r
1 EXISTING EQUIPMENT LAYOUT
eat&t
AT&T MOBILITY
RTC BUILDING 3
18221 HE 72nd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREONE
=NBULTING USA
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
PROJECT NICi 1 S15UC52
❑RAWN BY: A.F.
CHECKEC) BY: L„C,
SUBMITTALS
0 ; N2 100% FINAL CO'i ""
A SFP 1]/19 1511FD TOR UE" Ar
THE IAFOWM1ATION CONTANJEC IN THIS EET OF
CCCUMEM^ 45 PROPRIETARY BY NATLFE
ANY LSE OR ^�^ ^� 'RE OTHER THAN THP.T
VJF11Gi RELATES TO THE CLIENT NAM®IS
9TAICTLY PROHE3fiE0.
A6E SEAL
ftla�i
a �
A tr
a +
a �
s
''++WYWiada
SrM
DUMAS BAY
SSB5
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
_ WA SB023
FA *: 10092B76
SHEEP TRLE
EXISTING EQUIPMENT
LAYOUT
SHEEP NL�I.�BER
C-3
J
UL
R 11
TRUE NORTH ARROW SHOWN ON
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERIFIED
EXISTING WOOD FENCE
EXISTING P.T. RR -TIE
WOOD STEPS, TYP.
EXISTING
CHAINLINK
APPROVED
PLANNING
. City of Federal Way
Dept. of Community Develo ment
Permit #
By1
Date
1
1
4
t
T
v,
r
i
i
i
r
PROPOSED EQUIPMENT LAYOUT
NOTES:
1. INFORMATION OBTAINED FROM DRAWINGS PREPARED DY
PACIFIC TELECOM SERVICES DATED 12/07/2011.
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
SCOPE OF WORK
• INSTALL (1) ABIL/ASIK CARD IN EXISTING PURCELL
EQUIPMENT CABINET
• INSTALL (1) FSM4 MODULE IN EXISTING PURCELL
EQUIPMENT CABINET.
EXISTING (2) AT&T PURCELL EQUIPMENT
CABINET (STACKED) c/w (1) PROPOSED
ABIL CARD & (1) PROPOSED FSM4 MODULE
X — X — X — X
EXISTING AT&T UNDERGROUND CONDUIT
a/w tA) EXISTING 7/8- CABLES TO
EXISTING WOOD UTILITY POLE
at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREgr\jE
CONSUL-: 1 iJSA\
506 SECOND AVE, SUITE 1533
SEATTLE, WA 98104
PROJECT NQ 191 BL1052
ORAWN BY: A.F.
CHECKEO BY: LC.
SUBMITTALS
TTE INFDRMATIDN CAI-AINED IN Tl-IIS SET OF
DDCLJ IB s [S PFDPRI ARY BY NAT
ANY USEa dSCL !%OT1-IER TnANMAT
W.0 Rs-ATES TD THE G w NAM® IS
BTRICTLY PROHIBRED
DUMAS BAY
SSBS
DASH POINT RO. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 9BO23
FA #: 10092676
PROPOSED
EQUIPMENT LAYOUT
SHEEP NlNBER
C-4
EXISTING AT&T ANTENNA
INSTALLATION. REFER TO RF-1
FOR EXISTING ANTENNA LAYOUT
I
-.7
I
STING AT111T ANTEN"S.
I
37 -4 A,G.t.
I
I
I
T.. EXISTING NDLRY POLE
£XISTHIG AT�T AN'{ENNAS
I
I
--�
f E%fSIH3G 52'-q•
I
WOOD UTILITY POLE
EXISTING OVERHEAD
I! POWER LINE, TYP-
.
EI
f
'Z
-
I
ow—
{'!.%ti_
I
.r•n �_ or.e�
invw .1NP•_ _., �.w--� VNP—,
•� . � I_ z � pr,y
,
� I
I
fllfil IN 4ffffmrf.
/ \ � r — [i l l l l l 1111111 Ill
Cit
OP
C-3 COMPOUND ON GRADE — -- —
EXISTING SOUTH POLE ELEVATION
- 3/1G"=I'-0"
0. Lr
I.
I
I
I
I
I
I
I
AT&T ANTENNA INSTALLATION,
REFER TO RF-2 FOR
PROPOSED ANTENNA LAYOUT
1
1 PROPOSED AT&T AWENNAS
A .L
I
I
I T.O. E)CSTING UDLrtY POLE
PROPOSED AT&T ANTENNAS
A.G.L.
I
I
J
EXISTING 52'-0"
• WOOD UTILITY POLE
EXISTING OVERHEAD
1 POWER UNE, TYP.
I
e.�-r q.•p�� p�� �`'J'--• am „•�._� r•_.__ .
P_— ,Ir—• q � fl - — _,..� � �,.�a_ � a.•s-� _ ck� ol��.� e„o��= --- »�
I -
, I
NOTE:
1. ELEVATION IS DIAGRAMMATIC ONLY
APPROVED
PLANNING
City of Federal Way
Dept. of Community Development
Permit # 90-/Qo3!�& -g0-*4J)
By , l ► a 1� (:70) 8.17
Date a -) a - a60,d
1 AT&T EQUIPMENT
COMPOUND ON GRADE
PROPOSED SOUTH POLE ELEVATION
0
0 4' $'
a &t
AT&T Io10BIL11 f
RTC BUILDING 3
18221 NE 72nd WAY
REDIAOPID, WA 9P052
:•M asTec
Network Solutions
22263 63[h AVE S
KENT• WA 98032
CO,REONE
506 SECOND AVE. SUITE 1533
SEATTLE, WA 98104
PROJECT NO: 1 91 51-I052
DRAWN BY: Al.
CHECKED BY: LC
SUBMITTALS I
T-EII• S-SI IONCONTAINEDINTI-0SSET6=
O Y USE RS IS PROPRIETARY EBY
R NATLPE
ANYUSE U O TO—E OTHER THANTHAT
WHICH RELATES TO THE CLIENT NAMED IS
STRICTLY PROHIBfTEO.
A r�E ECRL
OUMAS BAY
SSB5
DASH POINT RO. 6
47TH AVE. S.W.
FEDERAL WAY,
WA SB023
FA #: 1 OOJ2676
SHEET -E
EXISTING 6 PROPOSEO
SOUTH POLE
ELEVATIONS
C-5
EXISTING ANTENNA CONFIGURATION AND SCHEDULE
SECTOR A
AZIMUTH
RADCENTER
NUMBER OF
ANTENNAS
VENDOR
MODEL
ELEC.
T)LT
MECH.
TJLT
RET
TMA
RRH
COUNT
RRH MODEL NO.
NUMBER OF
FEEDERS
FEEDER
TYPE
FEEDER
LENGTH
IDIPLEXED
LTE 700
110'
56'-7"
1
ALL AA3JR52703AAAA
1'
0'
NO
NONE
1
RRH2x40W_7L
1
FIBER
68'-D"t
NO
LTE 1900
1'
0
-
1
FIBER
68'-0"t
GSM 850
110,
50'-0"
1
KATHREIN
742-264
0'
0'
NO
NONE
0
-
NO
UMTS 850
0'
0
-
1
7/8'
1gg'-0"d:
UMTS 1900
0'
0
-
1
7/8'
199'-0"d:
SECTOR B
AZIMUTH
RADCENTER
INUMBER OF
ANTENNAS
VENDOR
MODEL
ELEC,
TILT
MECH.
TwT
RET
T,r,A
RRH
COUNT
RRH MODEL N0.
NUMBER OF
FEEDERS
FEEDER
TYPE
FEEDER
LENGTH
DlPL EXED
LTE 700
220'
56'-7"
1
ALL M
3JR52703PM4
1'
0'
NO
NONE
1
RRH2x4OW_7L
1
FIBER
68'-0"t
NO
LTE 1900
1'
0
-
1
FIBER
68'-D"f
GSM 850
220'
50'-0"
1
KATHREIN
742-264
0'
0'
NO
NONE
0
-
1
7/8
1g9'-O"d:
NO
UMTS 850
0'
0
-
1
7/8'
19g'-0"t
UMTS 1900
0'
0
-
1
7/8"
EXISTING ANTENNA CONFIGURATION AND SCHEDULE
DATA WAS OBTAINED FROM AT&T RF DATA SHEET
(DATED 07/17/2019) RFDS VERSION 2.1
EXISTING AT&T LTE
(RRH2x4OW_7L), T)
EXISTING 52'-6" W
EXISTING AT&T PAN
(LTE 700/1900) (T
OF (1) PER SECTO
rIPPROVED
PLANNING
City of Federal Way
Dept. of Community Development
Permit # RO' 100 3169 (a -a0- Ab
By .WAV10m. Gtold�n_
Date a-1a'Q'0a6
l^`Ii
TRUE NORTH ARROW SHOWN ON
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERIFIED
EXISTING ANTENNA CONFIGURATION
n.
0 ,, 2'
NOTES:
1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
PACIFIC TELECOM SERVICES DATED 12/07/2011.
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
E14NA
0)
:R SECTOR
*11 aMt
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREONE
CONSUL; INC- iJSA
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
PROJECT NO 1915LKD52
DRAWN BY: A.F.
CHECKED BY: LC.
SUBMITTALS I
100% FINAL
TI-E INFOWv1AT10N CONTAINED IN THIS SET _
DOCLMTfTS IS PROPRIETARY EIY NAT
ANY USE OR DISCLOSURE OT OR THAN THAT
WWCH FS =TO TF C MNAM® IS
STRICTLY PROHIBRED
SRE
DUMAS BAY
SS85
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 9B023
FA*:10092B7B
SHEEP TRIF
EXISTING ANTENNA
CONFIGURATIONS
SHEET.
RF-1
PROPOSED ANTENNA CONFIGURATION AND SCHEDULE
SECTOR A
AZIMUTH
RADCENTER
NUMBER OF
ANTENNAS
VENDOR
MODEL
ELEC.
TILT
MECH.
TJL7
RET
TMA
RRH
COUNT
RRH MODEL NO.
(NUMBER OF
FEEDERS
FEEDER
TYPE
FEEDER
LENGTH
OIPLEXED
LTE 700
110'
58'-0"
1
KATHREIN
80010992
1'
0'
NO
NONE
1
AIRSCALE DUAL RRH B12/14
7 1
FIBER
68'-0"f
NO
LTE 1900/AWS
1'
1
AIRSCALE DUAL RRH B25/66
1
FIBER
68'—O"t
LTE WCS
V
1
RRH4x25—WCS-4R
1
FIBER
68'—O"t
LTE 850
110,
48'-0"
1
KATHREIN
80010992
0'
0-
0'
NO
NONE
1
AIRSCALE 4T4R RRH B5
1
7/8'
199'—O"t
YES
UMTS 850
0
—
1
7/8'
1gg'-0"t
UMTS 1900
0'
0
—
1
7/8'
199'—O't
SECTOR B
AZIMUTH
RADCENTER
NUMBER OF
ANTENNAS
VENDOR
MODEL
ELEC.
TILT
MECH.
TILT
RET
TMA
RRH
COUNT
RRH MODEL N0.
(NUMBER OF
FEEDERS
FEEDER
TYPE
FEEDER
LENGTH
1)IPLEXED
LTE 700
110-
58'-0'
1
KATHREIN
80010992
1'
0-
NO
NONE
1
AIRSCALE DUAL RRH 812/14
1
FIBER
68'-0"t
NO
LTE 1900/AWS
1-
1'
1
AIRSCALE DUAL RRH 825/66
1
FIBER
68'—O"t
LTE WCS
1
RRH4x25—WCS-4R
1
FIBER
68'-0"t
LTE 850
110,
48'-0'
1
KATHREIN
80010992
0'
0'
NO
NONE
1
AIRSCALE 4T4R RRH B5
1
7/8"
199'—O"t
YES
UMTS 850
0'
0
—
1
7/6"
1gg'—O"t
UMTS 1900
0'
1 0
1
7/8'
199'—O"f
EXISTING ANTENNA CONFIGURATION AND SCHEDULE
DATA WAS OBTAINED FROM AT&T RF DATA SHEET
(DATED 07/17/2019) RFDS VERSION 2.1
SCOPE OF WORK
• REMOVE (1) EXISTING LTE 700/1900 PANEL ANTENNA,
TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED LTE 700/19OD/AWS/WCS
PANEL ANTENNA, TYP. OF (1) SECTOR
• REMOVE (1) EXISTING GSM 850/UMTS 850/1900
PANEL ANTENNA, TYP. OF (1) PER SECTOR.
• INSTALL (1) PROPOSED LTE 850/UMTS 850/1900
PANEL ANTENNA, TYP. OF (1) PER SECTOR
• REMOVE (1) EXISTING LTE 700 RRH (RRH2x4OW-7L)M
TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED LTE 700 RRH (AIRSCALE DUAL
RRH 4T4R 812/14), TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED LTE 1900 RRH (AIRSCALE
DUAL RRH 4T4R 825/66). TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED LTE 850 RRH (AIRSCALE RRH
4T4R B5), TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED LTE WCS RRH
(RRH4x25—WGS-4R), TYP. OF (1) PER SECTOR
• INSTALL (1) PROPOSED DIPLEXER (KAELUS
DBC0135F3V92-1), TYP. OF (2) PER SECTOR
MOUNT ALL PROPOSED EQUIPMENT AS
PER MANUFACTURER'S RECOMMENDATIONS
MODIFIED EXISTING ANTENNA MOUNT TO BE
COMPLETED TO BE WITH MOUNT ANALYSIS
APPROVED
PLANNING
City of Federal Way
Dept. of Community Development
Permit#o
gy ;�1ia G❑ aI.r
Date a" la aQ �A
EXISTING AT&T ANTENNA MOUNTING PIPE
TO BE REMOVED AND REPLACED WITH
NEW PIPE TO ACCOMMODATE PROPOSED
AT&T RRH's (LENGTH TO SUIT)
TRUE NORTH ARROW SHOWN ON
THIS DRAWING IS APPROXIMATE
ONLY AND MUST BE VERIFIED
EXISTING AT&T LTE 700 RRH (RRH2x4OW-7L) TO
BE REMOVED AND REPLACED WITH PROPOSED
AT&T LTE 700 RRH (AIRSCALE DUAL RRH B12/14),
TYP. OF (2). REFER TO RF-3 FOR DETAILS
PROPOSED AT&T LTE 1900 RRH
(AIRSCALE DUAL RRH B25/66), TYP. OF
(2). REFER TO RF-3 FOR DETAILS
EXISTING AT&T PANEL ANTENNA (LTE 700/1900) TO BE
REMOVED AND REPLACED WITH PROPOSED AT&T PANEL
ANTENNA (LTE 700/1900/AWS/WCS) (TOP), TYP. OF
(1) PER SECTOR. REFER TO RF-3 FOR DETAILS
�j
41
1
A� y.tiry
NOTES:
1. INFORMATION OBTAINED FROM DRAWINGS PREPARED BY
PACIFIC TELECOM SERVICES DATED 12/07/2011.
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
PROPOSED AT&T LTE 850 RRH
(AIRSCALE 4T4R RRH 95). TYP. OF
(2) REFER TO RF-3 FOR DETAILS
PROPOSED AT&T LTE WCS RRH
(RRH4.25—WCI TYP. OF (2),
REFER TO RF-3 FOR DETAILS
TRANSFORMER
EXISTING AT&T PANEL ANTENNA (GSM 850/UMTS 850/1900)
TO BE REMOVED AND REPLACED WITH PROPOSED AT&T
PANEL ANTENNA (LTE 850/UMTS 850/1900) (BOTTOM),
TYP. OF (1) PER SECTOR REFER TO RF-3 FOR DETAILS
L]�
,4'+fA/i
� To-
EXISTING 52'-6' WOOD UTILITY POLE
PROPOSED AT&T DIPLEXER, TYP. OF (2)
(STACKED). REFER TO RF-3 FOR DETAILS
EXISTING AT&T ANTENNA MOUNTING PIPE
TO BE REMOVED AND REPLACED WITH NEW
PIPE TO ACCOMMODATE PROPOSED AT&T
ANTENNAS (LENGTH TO SUIT), TYP. OF (2)
PROPOSED ANTENNA CONFIGURATION
22 34
0 , 2
atm
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
•:•M asTec
Network Solutions
22263 68Lh AVE S
KENT. WA 98032
COREONE
CorJSUL s INC34 LiSA
506 SECOND AVE, SUITE 1533
SEATTLE. WA 98104
PROJECT NO 1 g 15L1052
DRAWN BY: A.F.
C-IECKED BY: L,C.
SUBMITTALS
TFE I�FORNMTON CCNTAINEO IN THI66Ef 6
ppCLMBYT519 RRCRFiIETARY BY NAiLFIE
ANY LI9E OR CI6CLp9JRE OTHER THAN THAT
WHICH RELATES TFE CLISYT NAN® IS
STRICTLY PRCFiIBREQ
SITE
DUMAS BAY
SS65
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 96023
FA *: 10092676
SHEET
PROPOSED ANTENNA
CONFIGURATIONS
SHEET NLAA6ER
RF-2
MANUFACTURER: KATHREIN
MODEL 80010992
WEIGHT: 133.4 LEIS
DIMENSIONS: 105.2" X 20.0" X 6.9"
FREQUENCY: REFER TO RF DATA SHEET
20.0
TOP
20.0
RF CONNECTOR, TYP BOTTOM
20.0
FRONT
MECHANICAL
DOWNTILT
BRACKET
_-T
ANTENNA DETAIL
- N.T.S.
O SOLAR
srllELv
15.4"
TOP
1&1-19
F9"
RF CONNECTOR, TYP
MANUFACTURER: NOKIA
MODEL: AIRSCALE DUAL RRH 4T4R 825/66
HEIGHT: 28.7"
WIDTH: 15.4"
DEPTH: 9.6"
WEIGHT: 88.2 LBS
RRH DETAIL
rLTs.
SOLAR
MANUFACTURER: NOKIA
MODEL., AIRSCALE RRH 4T4R B5 (OR SIMILAR)
HEIGHT: 13.3"
WIDTH: 11.6"
DEPTH: 6.5"
WEIGHT: 36.8 LBS
RRH DETAIL
IJTS
pj
FRONT
SOLAR
12" SHIELD -
TOP
RRH o MOUNTING
BRACKETS
ISO VIEW
.tl
H
MANUFACTURER: ALCATEL-LUCENT
MODEL: RRH4X25-WCS
HEIGHT: 31.5"
WIDTH: 12"
DEPTH: 8.7"
WEIGHT: 70 LBS
FRONT
RRH DETAIL
N T.S.
SOLAR
SHIELD
MANUFACTURER: NOKIA
MODEL: AIRSCALE DUAL RRH 4T4R 812/14 (OR SIMILAR)
HEIGHT: 28.7"
WIDTH: 15.4"
DEPTH: 9.6"
WEIGHT: 101.4 LBS
3 RRH DETAIL
H T.S
MOUNTING
MANUFACTURER: KAELUS
MODEL: DBC0135F3V92-1
DIPLEXER
10.13"
UNISTRUT SECURED
TO MOUNTING PIPE
�'_MOUMING PIPE
g DIPLEXER DETAIL
N,T,S
jWamt
AT&T MOBILITY
RTC BUILDING 3
18221 NE -,2nd WAY
REDMOND. WA 98052
": M asTec
Network Solutions
22263 681h AVE S
KENT. 'WA 98032
r COOEONE
506 SECOND AVE. SUITE 1533
SEATI LE, WA 98104
PROJECT _ 1915L1�2
OFIAWN BY: A F.
CHECKEO BY: Lam,
SUBMITTALS
THE INFORMATION �AINEO IN T-IIS EFT OR
00,, M5Is PROPRIETARY E Y NATWE
AW USE OR OIS—OSURE OTHER THAN THAT
WHICH RELATES TOTHECUEN NAMEOIS
STRIOTLY PROHIETTEO.
A6E SEAL
rr�r.r�s
■
9 N
R �
a �
4�• ib�
pevw Ysr
SITE
DUMAS BAY
SSBS
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA BB023_
FA #: 10052B7B
SHEET TITLE
RF 6 EQUIPMENT
DETAILS
SHEET NA.MBER
RF-3
. 1-
EXISTING
MOUNT,
INSTALL (3) 20" LONG
L3X3X1/2" ANGLES. CONNECT
THE ANGLES TO THE CORNER
ANGLES WITH (1) 1/2" A36
BOLT AT EACH ANGLE TO
ANGLE CONNECTION (TYP.) xx
/aL
APPROVED
PLANNING
City of Federal Way
Dept. of Community Developrpent
Permit #�
By MA
a * 1 -()to koq
Date. a-1�-aoda
MOUNT MODIFICATION ISOMETRIC VIEW
N.T S
j 5'TYP
I
NOTES:
1. REFER TO GN-1 FOR SPECIFICATIONS
2. CONTRACTOR TO SITE VERIFY ALL DIMENSIONS AND
CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
1/2" A36 BOLT (TYP.)
INSTALL (3) 20" LONG
1_3X3X7/2" ANGLES. CONNECT
THE ANGLES TO THE CORNER
ANGLES WITH (A36
A
BOLT AT EACH ANGLE
TO
ANGLE CONNECTION (TYP.)
ovINSTALL (3) 4" LONG L3X3X1/2
ANGLES. ATTACH THESE CORNER
ANGLES TO THE EXISTING PIPE
MOUNT USING (1) 1/2" U-BOLT
PER CORNER ANGLE (TYP.)
*at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 98052
.:•M asTec
Network Solutions
22263 68th AVE S
KENT. WA 98032
a CORE'q
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
VPROJECT Na. 1915U052
DRAWN BY: A.F.
r
C:HECKEO BY: LC.
•; MOUNT MODIFICATION (PLAN VIEW)
N.T•5
EXISTING PIPE
MOUNT (TYP.)
INSTALL (3) 20" LONG
1_3X3X1/2" ANGLES. CONNECT
THE ANGLES TO THE CORNER
ANGLES WITH (1) 1/2" A36
BOLT AT EACH ANGLE TO
ANGLE CONNECTION (TYP.)
1/2" A36 BOLT (TYP.)
PROPOSM 1/2" U-BOLT (TYP.)
INSTALL (3) 4" LONG L3X3X1/2
ANGLES. ATTACH THESE CORNER
ANGLES TO THE EXISTING PIPE
MOUNT USING (1) 1/2" U-BOLT
PER CORNER ANGLE (TYP.)
ANGLE TO ANGLE CONNECTION DETAIL
N.T. 5
INSTALLATION OF ALL SECTOR
REINFORCEMENT KITS MUST BE COMPLETED
PRIOR TO ANTENNA AND RRH INSTALLATIONS.
SUBMITTALS
THE NF0. NIAT�N GONTAINEO IN THIS SET OF
OOCLSE OR ISCLOSURE 07 SY NATlk�E
ANY ROROISCIOS CIENT THAN THAT
W WGi RELATES IT TI-� CLIENT NAM® IS
STPoCTLY PROHIBrTE0.
SITE
DUMAS BAY
SS65
DASH POINT RO.6
47TH AVE. S.W.
FEDERAL WAY,
WA J6023
FA #: 10092676
SHEET TRLE
CONSTRUCTION
DETAILS I
SHEET NLJNBEFi
S-1
GENERAL NOTES:
1. EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF
PROPOSED WORK TOGETHER WITH THE WORK OF ALL OTHER TRADES AND
INCLUDE IN THE BID PRICE ALL COSTS FOR WORK SUCH AS EQUIPMENT
AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS
SHOWN AND SYSTEMS OF OTHER TRADES.
2. SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE
CONDITIONS AND WORK TO BE PERFORMED UNDER THIS CONTRACT
3. PERFORM DETAILED VERIFICATION OF WORK PRIOR TO ORDERING THE
ELECTRICAL EQUIPMENT AND COMMENCING CONSTRUCTION. ISSUE A WRITTEN
NOTICE TO THE CONSULTANT OF ANY DISCREPANCIES.
4. OBTAIN ALL PERMITS, PAY ASSOCIATED FEES AND SCHEDULE INSPECTION.
5. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, INSURANCE. AND SERVICES TO
COMPLETE THIS PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS
AND PRESENT IT AS FULLY OPERATIONAL TO THE SATISFACTION OF THE
OWNER.
6. CARRY OUT WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY AND
LOCAL CODES AND O.S.H.A.
7. PRIOR TO BEGINNING WORK COORDINATE ALL POWER AND TELCO WORK WITH
THE LOCAL UTILITY COMPANY AS IT MAY APPLY TO THIS SITE. ALL WORK TO
COMPLY WITH THE RULES AND REGULATIONS OF THE UTILITIES INVOLVED.
8. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL
BE DONE IN A FIRST CLASS WORKMANSHIP PER NECA STANDARD 1-2000
BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL
SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE
PROGRESS OF THE PROJECT.
9. DURING PROGRESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF THE
INSTALLATION OF THE ELECTRICAL SYSTEMS, LOCATING EACH CIRCUIT
PRECISELY AND DIMENSIONING EQUIPMENT, CONDUIT AND CABLE LOCATIONS.
UPON COMPLETION OF THE INSTALLATION, TRANSFER ALL RECORD DATA TO
BLACK LINE PRINTS OF THE ORIGINAL DRAWINGS AND SUBMIT THESE
DRAWINGS AS RECORD DRAWINGS TO THE CONSULTANT.
10. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR
AFTER THE DATE OF JOB ACCEPTANCE BY OWNER, ANY WORK, MATERIAL,
OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE
CORRECTED AT ONCE UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE
CONTRACTOR.
11. GENERAL CONTRACTOR IS RESPONSIBLE FOR REQUESTING CONNECTION OF
COMMERCIAL POWER FROM THE POWER COMPANY. ELECTRICAL CONTRACTOR
SHALL COORDINATE THIS WORK WITH THE GENERAL CONTRACTOR.
12. COORDINATE EXACT TELEPHONE REQUIREMENTS AND SERVICE ROUTING WITH
LOCAL TELEPHONE COMPANY. APPLY FOR TELEPHONE SERVICE IMMEDIATELY
UPON AWARD OF CONTRACT.
BASIC MATERIALS AND METHODS:
1. ALL ELECTRICAL WORK SHALL CONFORM TO THE EDITION OF THE NEC
ACCEPTED BY THE LOCAL JURISDICTION AND TO THE APPLICABLE LOCAL
CODES AND REGULATIONS.
2. ALL MATERIALS AND EQUIPMENT SHALL BE NEW. MATERIALS AND EQUIPMENT
SHALL BE THE STANDARD PRODUCTS OF MANUFACTURER'S CURRENT DESIGN.
ANY FIRST-CLASS PRODUCT MADE BY A REPUTABLE MANUFACTURER MAY BE
USED PROVIDING IT CONFORMS TO THE CONTRACT REQUIREMENTS AND MEETS
THE APPROVAL OF THE CONSULTANT AND THE OWNER.
3. ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS
SHOWN, PROVIDING PROPER CLEARANCES AND ACCESS. CAREFULLY EXAMINE
ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH LOCATION WITHOUT
SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF
FIELD CONDITIONS OR OTHER CAUSES, PREPARE AND SUBMIT DETAILED
DRAWINGS FOR ACCEPTANCE.
4. THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS,
BENDS, FITTINGS AND ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE
ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT THE WORK TO THE
CONDITIONS.
5. MAINTAIN ALL CLEARANCES AS REQUIRED BY NEC.
6. SEAL AROUND CONDUITS AND AROUND CONDUCTORS WITHIN CONDUITS
ENTERING THE MODULAR CABINETS WHERE PENETRATION OCCURS WITH A
SILICONE SEALANT TO PREVENT MOISTURE PENETRATION INTO BUILDING.
7. SILICONE SEAL AROUND ALL BOLTS AND SCREWS USED TO SECURE
EQUIPMENT TO EXTERIOR OF BUILDING.
8. MAKE NECESSARY CONNECTIONS FOR BATTERY IN EMERGENCY LIGHT FIXTURE.
CONNECT EXTERIOR LIGHT FIXTURE (PROVIDED BY SHELTER MANUFACTURER)
TO EXTERNAL JUNCTION BOX.
CONDUCTORS AND CONNECTORS:
1. UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER, MINIMUM
SIZE #12 AWG, WITH THERMOPLASTIC INSULATION CONFORMING TO NEMA
WC5 OR CROSS-UNKED POLYETHYLENE INSULATION CONFORMING TO NEMA
WC7. (TYPES THHN OR THWN). INSULATION SHALL BE RATED FOR 90
CONDUCTORS SHALL BE COLOR CODED IN ACCORDANCE WITH NEC.
2. ALL CONDUCTORS USED FOR GROUNDING SHALL BE COPPER AND SHALL
HAVE GREEN INSULATION.
3. FOR COPPER CONDUCTORS #6 AWG AND SMALLER USE 3M SCOTCH-LOK OR
T&B STA-KON COMPRESSION TYPE CONNECTORS WITH INTEGRAL OR
SEPARATE INSULATION CAPS. FOR COPPER CONDUCTORS LARGER THAN #6
AWG USE SOLDERLESS, IDENT HEX SCREW OR BOLT TYPE PRESSURE
CONNECTORS OR DOUBLE COMPRESSION C-CLAMP CONNECTORS, UNLESS
SPECIFIED OTHERWISE ON DRAWINGS.
4. UNLESS NOTED OTHERWISE ALL LUGS SHALL BE TIN PLATED COPPER,
TWO -HOLE, LONG BARREL, COMPRESSION TYPE.
RACEWAYS AND BOXES:
1, ALL CONDUIT SHALL BE UL LABELED.
2. ALL EMPTY CONDUITS INSTALLED FOR FUTURE USE SHALL HAVE A PULL
CORD.
3. SHEET METAL BOXES SHALL CONFORM TO NEMA OS1; CAST -METAL BOXES
SHALL CONFORM TO NEMA 81 AND SHALL BE SIZED IN ACCORDANCE WITH
NEC UNLESS NOTED OTHERWISE.
GROUNDING:
1. ALL SAFETY GROUNDING OF THE ELECTRICAL EQUIPMENT SHALL BE CARRIED
OUT IN ACCORDANCE WITH THE CURRENT REVISION NEC.
2. GROUND LUGS ARE SPECIFIED UNDER SECTION 3 "CONDUCTORS AND
CONNECTORS".
3. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH
ANTI -OXIDANT AGENT, SUCH AS NO-OX, NOALOX, PENETROX OR
KOPRSHIELD.
4. GROUND ALL EXPOSED METALLIC OBJECTS ON BUILDING EXTERIOR INCLUDING
BUILDING TIE DOWN BRACKETS.
5. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND
CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT.
6. DO NOT INSTALL GROUND RING OUTSIDE OF PROPERTY LINE.
7. REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING
GROUND CONNECTIONS, REPAINT TO MATCH AFTER CONNECTION IS MADE TO
MAINTAIN CORROSION RESISTANCE.
8. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING
SHALL BE #2 AWG SOLID BARE TINNED COPPER. MAKE ALL GROUND
CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS.
THE RADIUS OF ANY BEND SHALL NOT BE LESS THAN 8' AND THE ANGLE
OF ANY BEND SHALL NOT EXCEED 90% GROUNDING CONDUCTORS SHALL BE
ROUTED DOWNWARD TOWARD THE BURIED GROUND RING.
9. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY
THERMO-WELDING WITH ERICO T-319 GALVANIZING BAR.
10. ALL GROUND CONNECTIONS SHALL BE APPROVED FOR THE METALS BEING
CONNECTED.
11. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED,
ALL EXOTHERMIC WELDS TO EXTERIOR GROUND RING SHALL BE THE
PARALLEL TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE TEE
EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN
DAMAGED BY EXOTHERMIC WELDING. USE SPRAY GALVANIZER SUCH AS HOLUB
LECTROSOL #15-501.
12. CONTRACTOR SHALL NOTIFY AT&T WHEN THE BURIED GROUND RING IS
INSTALLED SO THE REPRESENTATIVE CAN INSPECT THE GROUND RING BEFORE
IT IS BACKFILLED WITH SOIL CONTACT: AT&T PROJECT MGR.
13. FOR METAL FENCE POST GROUNDING, USE A HEAVY DUTY TYPE GROUNDING
CLAMP OR EXOTHERMIC WELD CONNECTION TO POST.
14. WHERE MECHANICAL CONNECTORS (TWO -HOLE OR CLAMP) ARE USED, APPLY
A LIBERAL PROTECTIVE COATING OF AN ANTI -OXIDE COMPOUND SUCH AS "NO
OXIDE A" BY DEARBORN CHEMICAL COMPANY ON ALL CONNECTORS.
15. BOND ALL EXTERIOR CONDUITS, PIPES AND CYLINDRICAL METALLIC OBJECTS
WITH A PENN-UNION GT SERIES CLAMP, BLACKBURN GUV SERIES CLAMP OR
A BURNDY GAR 3900BU SERIES CLAMP ONLY, NO SUBSTITUTES ACCEPTED.
e0l amt
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
•:•M asTec
Network Solutions
22263 E8th AVE S
KENT, WA 98032
COREONE
506 SECOND AVE, SUITE 1533
SEATTLE. WA 98104
PROJECT Na. 1915U052
OFWWN BY: A.F.
CHECKED BY: LC,
SUBMITTALS
101
DEC M/191
1DOA FINAL CVk
trl
A
SCP 17/1g
15S0E0 rpB *Emcw
AF
THE IIFORNUTICIN CWTAINEO IN Tl-0S SET OF
3 DCrLMs Is PR]FiiIETARY BY NATURE
ANY U OR CIBCL RE 0T 12R THAN THAT
WHldi RELATES TO THE CLIENT NAM®15
STRCTLY PR]HIBffEO
AM-SPAL
9
M 0.
49
� c
• a
aA
a� 6
SRE
DUMAS BAY
SS65
DASH POINT RO.6
47TH AVE. S.W.
FEDERAL WAY,
WA 96023
FA x; 1009267B
SHEET TRLE
GROUNDING NOTES
SHEET NJMSER
G-1
PROPOSED REMOTE RADIO
(AIRSCALE DUAL RRH On,
LTE 1900 (TYP. PER SECI
PROPOSED REMOTE RADIO HEAD
LTE 700 E(TYP. PERDUALHSECTOB12R)4)
PROPOSED REMOTE
RADIO HEAD AIRSCALE
RRH 4T411 BS LTE 8SO
(TYP. PER SECTOR)
#6 AWG STRANDED GREEN JACKET
BONDING RRH UNIT GROUND TO
ANTENNA GROUND BUSS BAR
(TYP. EACH SECTOR)
PROPOSED PANEL ANTENNA. SEE
SHEET RF-1 FOR SITE CONFIGURATION
EXISTING ANTENNA GROUND BUSS BAR NEAR ANTENNAS WITH
COAX GROUND KIT. SEE DETAIL 5/G-3 FOR GROUND BAR
CONSTRUCTION, SEE DETAIL 4/G-3 FOR GROUND WIRE
CONNECTIONS, AND SEE DETAIL 3/G-3 FOR COAX GROUNDING.
PROPOSED REMOTE RADIO
HEAD (RRH4r25-WC5-4R) LTE
VMS MP. PER SECTOR)
I I llll
r
EXISTING AT&T DC2
SURGE SUPPRESSOR
(TYP. EACH SECTOR)
lral7j�-
TYPICAL ANTENNA GROUNDING PLAN
N T, S,
GROUNDING NOTES:
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS, ACTUAL
INSTALLATION AND CONSTRUCTION MAY VARY DUE TO
SITE SPECIFIC CONDITIONS.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS,
AND OTHER METALLIC COMPONENTS USING GROUND
WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS.
FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES
FOR GROUNDING REQUIREMENTS GROUND COAX SHIELD
AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING
MFR'S PRACTICES.
3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL
WIRES SHALL BE COPPER THHN/THWN. ALL GROUND
WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND.
4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE.
GROUNDING AND OTHER OPERATIONAL TESTING WILL BE
WITNESSED BY NETWORK CARRIER REPRESENTATIVE.
5. REFER TO CURRENT NEL; GENERAL ELECTRICAL
PROVISION AND COMPLY WITH ALL REQUIREMENTS OF
GROUNDING STANDARDS.
6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN
OF GROUNDING SYSTEM, AND RECEIVE APPROVAL OF
DESIGN BY AUTHORIZED AT&T MOBILITY REPRESENTATIVE,
PRIOR TO INSTALLATION OF GROUNDING SYSTEM.
PHOTO DOCUMENT ALL CADWELDS AND GROUND RING
7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY
DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO
SITE SOIL CONDITIONS.
GROUNDING ROO NOTES:
1. ELECTRICAL CONTRACTOR SHALL ORDER GROUND
RESISTANCE TESTING ONCE THE GROUND SYSTEM HAS
BEEN INSTALLED; A QUALIFIED INDIVIDUAL, UTILIZING THE
FALL OF POTENTIAL METHOD, SHOULD PERFORM THE
TEST. THE REPORT WILL SHOW THE LOCATION OF THE
TEST AND CONTAIN NO LESS THAN 9 TEST POINTS
ALONG THE TESTING LINE. GRAPHED OUT TO SHOW THE
PLATEAU.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS,
AND OTHER METALLIC COMPONENTS USING GROUND
WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS.
FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES
FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD
AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING
MFR'S PRACTICES.
atm
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND. WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
COREONE
CONSULTING USA
506 SECOND AVE, SUITE 1533
SEATTLE, WA 9B104
PROJECT NCk 191 SLJD52
DRAWN BY. AF,
CHECKED BY. LC.
SUBMITTALS I
0 I DEC 2 /19 1COC FINAL CD's SN
A SEP 17/19 L6VEP POR REM A
TrE mFawnanaN conrrAwEQ IN Twe � r of
oocunnQ.rtsls �_ IE-raaY ar ninns�.
ANY LASE OA CI �CRHEIi TIWN TNT
WHICH RELATES TO h1E CLIENT NAM® Ei
9TFYCTLY PROHIEPTEQ
slf
DUMAS BAY
SS65
DASH POINT RD. 6
47TH AVE. S.W.
FEDERAL WAY,
WA 96023
FA n: 10092676
sir mLE
SCHEMATIC
GROUNDING PLAN
s�ET N�ER
G-2
1 CADWELD GROUNDING CONNECTIONS
NJ S.
INNA
CABLE GROUND 6 AWG FROMAKIT
COPPER GROUND
BAR ON WALL, ICE
BRIDGE, FLOOR OR
ON ANTENNA TOWER
*TWO HOLE LUG, OR
EXOTHERMIC WELD TO BE
USED WITH 12 AWG BCW TO
GROUND CONDUCTOR SHALL
BUILDING SERVICE GROUND
BE ELIMINATED WHEN
OR GROUND RING
GROUND BAR IS
ELECTRICALLY BONDED TO
NOTE:
METAL TOWER/MONOPOLE
GROUND BARS AT BOTTOM OF TOWERS/MONOPOLES
STRUCTURE
SHALL ONLY USE EXOTHERMIC WELDS.
4 GROUND WIRE INSTALLATION
- NTS.
TYPICAL FOR
ALL SECTORS
PROPOSED PANEL ANTENNA
(TYP. EACH SECTOR)
SEE SHEET RF-1 FOR
EXISTING CONFIGURATION
EXISTING ANTENNA GROUND BAR NEAR
EXSTING ANTENNAS WITH COAX GROUND
KIT. SEE DETAIL 5/G-2 FOR GROUND WIRE
CONNECTIONS, AND SEE DETAIL 3/G-2 FOR
COAX GROUNDING (TYP EACH SECTOR)
#6 AWG STRANDED GREEN JACKET
BONDING PANEL ANTENNA TO
ANTENNA GROUND BAR
(TYP. EACH SECTOR)
EXISTING GROUND TO
ANTENNA GROUND BAR AT
NEXT SECTOR (TYR)
TYPICAL ANTENNA GROUNDING PLAN
NTS
TO ANTENNAS
RX2 �TX1/RX1
COAX JUMPER)
(TYP. )
CONNECTOR
WEATHERPROOFING
KIT (TYP.) SEE NOTE 2
WEATHERPROOFING
KIT (TYP.)
GROUND KIT (TYP.)
#6 AWG
ISOLATE FROM TOWER HALO
W/ #2 TO LOWER TOWER BUS
BAR
ANTENNA CABLE BAR WITH PER NINSULATORS.
TENNA GROUND
TO BTS EQUIPMENT (TYP.) BONDED DIRECTLY TO TOP OF
MONOPOLE OR UTILITY POLE
NOTES: TO GROUND RING
DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE
DOWN TO ANTENNA GROUND BAR.
WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED.
2 GROUND CABLE CONNECTION
N.T.S.
NEW CG tAL GROUND KM W/ LONG
BARREL COMPRESSION DOUBLE LUGS,
ATTACH TO GROUND BAR & INSTALL BY
NOTE: COAT ALL MECHANICAL
ANTENNA CONTRACTOR (CADWELD TYPE-GL)
CONNECTIONS WITH "NOOX"
OR APPROVED EQUAL
NEW 4-x 24"x 1/4"thk COPPER GROUND
BAR, INSTALLED BY GENERAL CONTRACTOR
O
O
0000 ❑
0 0 0 0 0 0 0 0 0000
a
0 0000 O
0 0 0 0 0 0 0 0 0000 O
0 0 0 0 0 0 0 0 0 0 0 Ca
#2 SOLID BARE TINNED
COPPER WIRE CADWELD
(TYPE-GL)
5 GROUND BAR
N T. S.
ANTENNA CABLE 1- -. 1
WEATHERPROOFING KIT
(SEE NOTE 3)
CABLE GROUND KIT
#6 AWG STRANDED COPPER
GROUND WIRE (GROUNDED TO
GROUND BAR). SEE NOTE 1 & 2
CABLE CONNECTOR
NS
1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE
DOWN TO GROUND BAR.
2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY
CABLE MANUFACTURER.
3.WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED.
CABLE GROUND KIT CONNECTION
\_LJ NT.S
WIRE SIZE
BURNDY LUG
BOLT SIZE
#6 AWG GREEN INSULATED
YA6C-2TC38
3/8" - 16 NC S 2 BOLT
#2 AWG SOLID TINNED
YA3C-2TC38
3/8" - 16 NC S 2 BOLT
#2 AWG STRANDED
YA2C-2TC38
3/8- - 16 NC S 2 BOLT
#2/0 AWG STRANDED
YA26-2TC38
3/8- - 16 NC S 2 BOLT
#4/0 AWG STRANDED
YA28-2N
1/2" - 16 NC S 2 BOLT
MOTES:
1. ALL HARDWARE BOLTS, NUTS, LOCK WASHERS
SHALL BE STAINLESS STEEL. ALL HARDWARE
ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,
GROUND BAR, GROUND LUG, FLAT WASHER AND NUT.
2. COPPER SHIELD, ANTIOX, CR NO-OX OR EQUIVALENT
SHALL BE PLACE WHERE ALL DISSIMILAR METALS CONNECT-
3, ALL LUGS ARE TO BE INSTALLED PER MANUFACTURER'S
SPECIFICATIONS,
GROUNDING CONDUCT(
HEAT SHRINK (CLEAR)
BURNDY GROUND LUG
(SEE TABLE FOR SIZE
AND MODEL)
LOCK WASHER (TYP.)-
NUT (TYP.)
GROUND BAR
BOLT (TYP.)
—BURNDY TWO HOLE LUG WITH
LONG BARREL FOR #6 AWG
STRANDED OR EQUIVALENT
BARE WIRE TO BE
NO-OX AT BOTH ENDS
6REEDED
NGINSULATED
MECHANICAL LUG CONNECTION
NTS,
*at&t
AT&T MOBILITY
RTC BUILDING 3
18221 NE 72nd WAY
REDMOND, WA 98052
•:•M asTec
Network Solutions
22263 68th AVE S
KENT, WA 98032
a C0REONE
.�° CONSUL--1NG !JSP.
506 SECOND AVE. SUITE 1533
SEATTLE. WA 98104
PROJECT NO: I S 15UO52
DRAWN BY: A.F.
CHECKED BY: L.C.
SUBMITTALS
THE IfFOCW VaTON CONTAINEO IN THIS SEA CE
p�CJ_MENTS 19 PRO'RIETARY SY NATLIF�
ANY LISE OR OIECLOSURE QTl-FJi THAN hIAT
WHICk-I R6ATES TD THE CUEM NAM® IS
STRICTLY RaOHIBfiEO,
A6E SEAL
SRE
DUMAS BAY
SSB5
DASH POINT RO.S
47TH AVE. S.W.
FEDERAL WAY,
WA 9BO23
FA *: 1009267E
SI-E:ET TRLE
GROUNDING DETAILS
SHEEP M.Jtr1BER
G-3