Loading...
19-104375r "k r CITY OF Federal Way Centered on Opportunity February 20, 2020 Ms. Joy Dayaw MG2 Corporation 1101 2nd Avenue, Suite 100 Seattle, WA 98101 Re: File #19-104375-00-UP; PROCESS I DIRECTOR'S APPROVAL Ivar's Resturaunt Addition; 2004 South 320th Street, Federal Way Dear Ms. Dayaw. CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com Jim Ferrell, Mayor FILE The City of Federal Way's Department of Community Development is in receipt of your Use Process I Master Land Use PMLU) application resubmitted on December 23, 2019, for a 471.5 square foot addition to an existing 1,893 square foot restaurant building at 2004 South 3201' Street, Federal Way (parcel #092104- 9297). The Process I MLU application is hereby approved pursuant to conclusions based on findings made by the department's Planning Division. Please note — this approval is limited to the design review of the exterior addition only and does not constitute building permit approval that is required prior to construction. CONCLUSIONS Various sections of the zoning and development code indicate that certain developments, activities, or uses are permitted only if approved using Process I, Director's Approval. Based on the findings below, the proposed improvements to the developed site meet the following Process I approval criteria and land use review thresholds of Federal lay Revised Code (fWRC) 19.15.030(1) and 19.55.020: 1. The proposed improvements are consistent with applicable chapters of FWRC Title 19 including, but not limited to: Permits and Review Processes; Process I, Director's Approval; Community Design Guidelines; and City Center -Core (CC-C); 2. The health, safety, and welfare of the citizens of the city are preserved; 3. The proposal is a "minor new construction" exempt from SEPA review per the city's flexible thresholds as proposed new gross floor area or parking stalls will not exceed environmental thresholds; 4. There is no change of use; 5. There is no reduction in the amount of required landscaping, buffering, open space, or public areas; 6. There is no material change or reduction in the amount of required parking; 7. There is no material change in the location of utilities, easements, or pedestrian connections; 8. There is no material change to the approved architectural design; and 9. There are no additional adverse impacts to critical areas. Ms. Joy Dayaw Page 2 of 4 February 20, 2020 FINDINGS OF FACT 1. Proposal — The applicant resubmitted a Process I MLU application on December 23, 2019, proposing to install a 12' x 32' 6" (390 square feet) addition to the south side of the existing building; as well as an 11' 6" x 7' 1" (81.5 square feet) walk-in cooler/freezer addition on the north side of the existing building. The 471.5 square feet of additional space is a 24.9 percent improvement to the existing 1,893 square foot restaurant building. An approximately 48' x 26' (approximately 850 square feet) "L" shaped expanded outdoor seating area is proposed, wrapping around the building addition. New food service equipment is proposed to be installed in the existing kitchen footprint. New restroom plumbing fixtures are proposed to be installed in the existing bathrooms. New exterior doorways and interior walls are proposed to be installed within the existing footprint of the building. The design of the addition includes removing the existing sloped tile roof. The addition changes the architectural character of the existing building, built in 1978, to feel more in character with the adjacent plaza buildings that are currently being renovated. The renovations will maintain the existing roof height and structure. The proposed exterior renovations also include an updated color palette that is present in the recent Ivar's renovations throughout King County. Iconic brand elements will be added to the building exterior, such as the white and blue stripped awnings, "Ivar's" lit signs, and a "Keep Clam" graphic that's been tailored specific to Federal Way. 2. Comprehensive Plan & Zoning Designation — The subject property is located within a City Center -Core (CC- C) zoned area. Restaurants are permitted in CC-C zones pursuant to FWRC 19.225.040. 3. Community Design Guidelines Compliance The proposed restaurant addition complies with the provisions of FWRC Chapter 19.115, "Community Design Guidelines" that are reasonably related and applicable to the area of development as detailed below. a. Building Design — The building's primary entrances are located on the south (two) and east (one) fagades, and are clearly visible from the right-of-way, Pete von Reichbauer Way South. A pedestrian plaza helps define the restaurant entries. Methods of articulation and accessory elements are incorporated in the overall architectural design. Windows along the west, south, and east fagades, awnings, signs, graphic designs, and variation in materials are all used to articulate blank walls. The west and east building fagades, which are longer than 60 feet and visible from a right-of-way, have incorporated "three of four" facade treatments. These treatments include facade modulation, canopies, and a pedestrian plaza. b. Pedestrian Circulation —A pedestrian walkway continues to be utilized in the renovated design, carrying over from the existing site design, and running from the main entrance to the driveway tract on the south side of the building. 4. Environmental Review — The proposed improvements are exempt from environmental review. Proposed new gross floor area and parking stall additions do not exceed the threshold for exemptions in FWRC 14.15.030(1)(c) & (d). 5. CriticalAreas— The proposed building addition exists within an area split between a 10-year and 100-year Wellhead Protection Zone, and will be required to submit a hazardous materials inventory pursuant to FWRC 19.145.490(1). No other environmentally critical areas or associated buffers are identified on this property. 19-104375-00-UP Doc I.D. 80134 Ms. Joy Dayaw Page 3 of 4 February 20, 2020 6. Chan$e of Use The proposal is not a change of use as the existing restaurant will continue operations after the proposed construction of additional restaurant space has been completed. 7. Maximmm Hecht- The height of the building is approximately 17' 1" above average building elevation (AABE). The height of the structure is below the 70-foot height maximum in the CC-C zone. 8. Parking — Pursuant to FWRC 19.225.040, restaurants require 1 parking stall for every 100 square feet of gross Floor area. The existing building is 1,896 square feet and requires 19 spaces, while the proposed addition will bring the building to 2,367 square feet and requires 24 spaces. The applicant proposes 24 parking stalls, meeting the minimum. In addition to the existing Ivar's standalone restaurant, there are three retail variety establishment buildings. Per FWRC 19.225.020, retail variety buildings in the CC-C require 1 parking space for every 300 square feet of gross floor area. The combined floor area of the three retail buildings is 66,000 square feet, which requires 220 parking spaces. With the additional 24 parking spaces for Ivar's, the lot requires 244 parking spaces to support all four buildings. The property lot currently provides 356 parking spaces, exceeding the amount required. 9. L andreaping Per FWRC 19.125.040(5), Type III landscaping shall be placed outside of the existing sight - obscuring fence surrounding the outdoor garbage enclosure on the north side of the building and between the abutting public rights -of -way. Please update site plans that will be submitted with the building permit application to reflect this requirement, as the land use permit application currently identifies no updates to existing landscaping. Final occupancy is subject to a Planning Division final inspection. As a condition of approval, the applicant shall schedule a final landscape inspection for the building permit completion approval. 10. Concurrenay — The city's Traffic Division reviewed the applicant's concurrency application (19-105950-00- CN) for a restaurant addition and concluded the proposed development will generate three new PM peak hour trips. The Traffic Division noted that all intersections impacted by one or more weekday evening peak hour trips from the proposed development will meet the level of service standards with programmed improvements. A Capacity Reserve Certificate was issued February 12, 2020. 11. T'ranspartalraon Impart Fee — In order to mitigate the impacts of new development on the city's street infrastructure, the applicant will be subject to the transportation impact fee (I'IF). The fee will be assessed and collected from the applicant at the building permit issuance. 12. Acceas — The proposal will use an existing access to a driveway tract south of the building, as well as an existing access north of the building, from the parking lot to connect to Pete von Reichbauer Way South. No new access points are proposed onto Pete von Reichbauer Way South. 13. Solid Waste and Recycling — The existing garbage enclosure and containers will meet current solid waste requirements, and are reviewed at the time of construction permits. The applicant will be required to improve the landscape screening around the storage area as detailed above in (9). 14. Starmvaier— The proposal meets the flow control and water quality standards in the 2016 King County Surface Water Design Mancta! (KCSWDlvI and Cat* of Federal Way Addendum. Doc. I.D. 80134 19-104375-00-UP Ms. Joy Dayaw Page 4 of 4 February 20, 2020 CONDITIONS 1. The applicant shall submit a completed Hazardous Materials Inventory at the time of construction. 2. The applicant shall submit a completed Solid Waste Spill Prevention plan at the time of construction. 3. Final planning and landscaping inspection is required prior to final occupancy. BUILDING PERMIT ISSUANCE REQUIRED The department's Building Division will review building, electrical, mechanical, plumbing, and sign permits associated with the building addition and additional tenant improvement work. No work may begin until the building permits are issued. APPEALS The effective date of this decision is February 20, 2020. Pursuant to FWRC 19.55.050, any person who commented on the application or requests a copy of this administrative decision may appeal the decision to the Federal Way Hearing Examiner by March 5, 2020. Any appeal must be in the form of a letter delivered to the Department of Community Development with the established fee. However, as you are the only party of record, you may waive your right to appeal this decision. If you wish to waive your right to appeal, you must do so in writing to the Department of Community Development. No work on the proposal may begin until the end of the appeal period or receipt of your waiver. CLOSING This land use decision does not waive compliance with future City of Federal Way codes, policies, and standards relating to this development. This Process I approval does not constitute approval of a building permit. If you have any questions regarding this decision, please contact Planning Intern William Golding at 253-835-2622, or v, lEam.golding@cityoffederalway.com. Sincerely, F f 1 Brian Davis, Director Community Development Department enc: Approved Site Plans and Elevations Commercial Building Permit Checklist Hazardous Materials Inventory Trash Enclosure Design & Spill Prevention BMPs Scott Sproul, Building Official 19-104375-00-UP Doc. I.D. 80134 .-1 CITY OF Federal Way Centered on Opportunity Ms. Joy Dayaw MG2 Corporation 1101 2nd Avenue, Suite 100 Seattle, WA 98101 joc.dapmQ ng2. 2M Re: File #19-104375-00-UP; TECHNICAL COMMENTS LETTER Ivar's Resturaunt Addition; 2004 South 320th Street, Federal Way Dear Ms. Dayaw: CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com Jim Ferrell, Mayor October 24, 2019 City of Federal Way staff has reviewed your September 12, 2019, submittal of documents related to the Ivar's Restaurant addition at 2004 South 320th Street, Federal Way (parcel #092104-9297). City departments have provided the following comments that will need to be addressed prior to approval of your application, or as otherwise noted. Questions regarding the technical review comments should be addressed to the referenced staff representative. COMMUNITY DEVELOPMENT — PLANNING DIVISION William Golding, 253-835-2622, william.golding@cityoffederalway.com 1. Please provide more specific details to the exact nature of the walk-in proposed to be constructed on the north -side of the building, and the spacing between the structure and the existing trash enclosure. Per Federal Way Revised Code (FWRC) 19.125.050(1), solid screening is required between mechanical equipment arid-ffi pub tI c right-of-way. Please pxo�rl-de a landscape plan detail ig Cr irgx quiretnents if das fact mechanical equipment. 2. Per FWRC 19.225.040, restaurants in the City Center -Core (CC-C) require one parking stall for every 100 square feet of gross floor area. The existing building is 1,896 square feet and requires 19 spaces, while the proposed additional will bring the building to 2,367 square feet and requires 24 spaces. Please provide a parking study detailing the e-xisting shared parking agreement for the total site, and document how the additional parking requirements will be met with existing parking on site, or if not, how parking requirements will be met. PUBLIC WORKS — DEVELOPMENT SERVICES DIVISION Ann Dower, 253-835-2732, ann.dower@cityoffederalway.com 1. The project as proposed does not trigger site development improvements. In the event that other department requirements result in adding, removing, or replacing impervious surface, then additional permits or information may be required. Ms. Joy Dayaw Page 2 of 3 October 24, 2019 PUBLIC WORKS — TRAFFIC DIVISION Sarady Long, 253-835-2743, sarady.long@cityoffederalway.com The proposed tenant improvement ano expansion of the exiting restaurant by approximately 472 square feet is expected to generate net new, PM peak hour trips. As such, the applicant will need to submit a concurrency permit application (see the enclosed application) along with the $1,721 application fee and traffic impact fee prior to building permit issuance or TI approval. Based on the current impact rate, the estimated fee is ,$5,876.75 (see enclosed TIF calculation). LAKEHAVEN WATER AND SEWER DISTRICT Brian Ashbury, 253-946-5407, basbury@lakehaven.org Lakehaven has no comment on this application/project, as based on the submittal it appears no existing and/or future Lakehaven water/sewer system facilities will be required, desired, or affected by the proposed land use action. Existing water and/or sewer service connections should be protected during construction (see enclosed sewer service record, SSCP 10072). Any sewer service work outside of a building requires a Lakehaven Sewer Service Connection Permit. If any water or sewer utility conflicts are encountered, the applicant should promptly contact Lakehaven for additional information. SOUTH KING COUNTY FIRE AND RESCUE Chris Cahan, 253-946-7243, Chris.Cahan@southkingfire.org 1. No comments on the proposed addition exist at this time. \ COMMUNITY DEVELOPMENT — BUILDING DIVISION -Qre-g Kirk, 253-835-2631, greg.kirk [r cityaffederalway.com _ 1. The structure will be treated as a new building permit application and must meet all current codes, including: • International Building Code (IBC), 2015 Washington State Amendments WAC 51-50 ■ International Mechanical Code (IMC), 2015 Washington State Amendments WAC 51-52 • Uniform Plumbing Code (UPC), 2015 Washington State Amendments WAC 51-56 & 57 • International Fire Code (IFC), 2015 Washington State Amendments WAC 51-54 • National Electric Code (NEC), 2014 • Accessibility Code (ICC/ANSI A117.1), 2009 • Washington State Energy Code (WSEC), 2015 WAC 51-11 Building Criteria. The following applies to the proposed structure. Please include in your permit submittals: ■ Occupancy Classification Type of Construction 19-104375-00-UP Doc. I.D. 79733 all Ms. Joy Dayaw Page 3 of 3 October 24, 2019 • Floor Area • Number of Stories • Fire Protection • Wind/Seismic: Basic wind sped 85 mph, Exposure B, 25-pound Snow Load Seismic Zone D-1 2. Building PermitApplication Process. A complete building permit application and commercial checklist are required. The commercial checklist will be completed by staff and provided at the time of land use approval. Copies of the application and checklist may be obtained on our website at: www. o-ffedePalway.com. Appointments are required for intake of new commercial building permit submittals. Please contact the Permit Center at 253-835-2607, or 12errnitr-enter(@,citvoffedergSygy.com. Some projects may require a third -party review or inspection. The cost to cover these fees is the responsibility of the applicant. Any third -party fee is in a(ldiht iLto regular permit fees and costs. The information provided is based on limited plans and information. The comments are not intended to be a complete plan review and further comments are possible at time of building permit plan review. CLOSING Once the revisions listed above are made, provide four paper copies of the site plan documents and narrative with the completed resubrnittal form (enclosed). Your Land Use Process I application cannot be completed until your concurrency application has been completed. Pursuant to FWRC 18.05.080, if an applicant fails to provide additional information to the city within 180 days of being notified that such information is requested, the application shall be deemed null and void and the city shall have no duty to process, review, or issue any decisions with respect to such an application. Please do not hesitate to contact me at william.golding@citpoffedexalway.com, or 25335-622, if you have questions regarding this letter or your application. Sincerely, William Golding Planning Intern enc: Resubmittal Form Concurrency Application Traffic Impact Fees Lakehaven Side Sewer Permit Lakehaven Site Map cs Ann Dower, Senior Engineering Plans Reviewer Brian Ashbury, Lakehaven Water and Sewer Sarady Long, Senior Transportation Planning Engineer Chris Cahan, South King Fire & Rescue Greg Kirk, Building Plans Examiner Dom I.D. 79733 19-104375-00-UP CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: October 2, 2019 TO: Cole Elliott, Development Services Manager Scott Sproul, Building Official Rick Perez, City Traffic Engineer Brian Asbury, Lakehaven Water & Sewer District Chris Cahan, South King Fire & Rescue FROM: William Golding FOR DRC MTG. ON: October 17, 2019- Completeness and Technical Review FILE NUMBER(s) : 19-104375-00-UP RELATED FILE NOS.: None PROJECT NAME: IVARS RESTAURANT PROJECT ADDRESS: ZONING DISTRICT: 2004 S 320TH ST CC-C PROJECT DESCRIPTION: Tenant improvement to an existing 1,893 square foot restaurant building, including a 471.5 square foot addition. Exterior renovation includes new materials, lighting and signage. LAND USE PERMITS: Use Process I. PROJECT CONTACT: JOY - DAYAW MG2 CORPORATION 1101 2nd Ave . , Suite 100 Seattle, WA 98101 Phone: (206) 962-6616 Email: joy.dayaw@mg2.com MATERIALS SUBMITTED. Master Land Use Application Project Narrative Site Plan Building Elevations (South & East) MG2 Corporation 1101 Second Ave, Ste 100 Seattle, WA 98101 December 20, 2019 City of Federal Way — Community Development Department Cc: Ivar's, Inc. Re: Ivar's Seafood Bar 2004 S 32011 St Federal Way, WA 98002 Subject: Use Process I — Revised Project Narrative RESUBMITTED DEC 2 3 2019 CITY OF FEDER4i_',VAY COMMUNITY DEVELOPMENT 206 962 6500 MG2.com The proposed Tenant Improvement project to the existing Ivar's Seafood Bar includes a 471.5 sq.ft. addition to an existing 1,893 sq.ft. restaurant. This addition is 21.9% of the existing building area which is less than the maximum 25% addition allowed for Use Process I. This scope of work covers an exterior renovation and addition that includes an extension of their existing dining area, extension of existing dining patio, and a new exterior walk-in cooler finished in colored metal panels to match the exterior palette. We will remove the existing sloped tile roof but maintain the existing roof height and structure, which dates to the initial Arthur Treacher's Fish and Chips built in 1978. By removing the sloped tile roof, the finished renovation will feel more in character with the adjacent plaza buildings that are currently being renovated. The proposed exterior renovation also includes an updated color palette that is present in the recent Ivar's renovations throughout King County. Iconic brand elements will be added to the building exterior such as the white and blue awnings, "Ivar's" lit signs, and a "Keep Clam" graphic that's been tailored specific to Federal Way. If you have any questions regarding this project, please contact me at (206) 962-6616. Thank you, t I ma=.1 Joy Dayaw, RA Associate MG2 1101 Second Ave. Ste 100 Seattle. WA 98101 December 20, 2019 To: Mr. William Golding Planning Intern City of Federal Way From: Joy Dayaw, RA MG2 1101 2"d Ave, Suite 100 Seattle, WA, 98101 Re: File #19-104375-00-UP, Technical Comment Response Letter Ivar's Restaurant Addition, 2004 South 320th Street, Federal Way 206 962 6500 MG2.com RESUBMITTED DEC 2 3 20119 CITY OF FEDERAL WAY COMMUNITY DEVEL00'.'7-4•" Please see the following responses that address the Use Process I technical comments letter provided on October 24, 2019. Community Development - Planning Division William Goldin Please provide more specific details to the exact nature of the walk-in proposed to be constructed on the north -side of the building, and the spacing between the structure and the existing trash enclosure. Per Federal Way Revised Code (FWRC) 19.125.050(1), solid screening is required between mechanical equipment and the public right-of-way. Please provide a landscape plan detailing screening requirements if this is in fact mechanical equipment. Response: The walk-in cooler/freezer is not a piece of mechanical equipment. The exterior of the walk-in will be finished in colored metal panels that will match the exterior palette. Attached for your reference is the finish chart of the available metal panel colors from the walk-in manufacturer. 2. Per FWRC 19.225.040, restaurants in the City Center -Core (CC-C) require one parking stall for every 100 square feet of gross floor area. The existing building is 1,896 square feet and requires 19 spaces, while the proposed additional will bring the building to 2,367 square feet and requires 24 spaces. Please provide a parking study detailing the existing shared parking agreement for the total site, and document how the additional parking requirements will be met with existing parking on site, or if not, how parking requirements will be met. Response: An existing parking plan and parking calculations is included on sheet A100. There are currently (4) buildings on the property lot: the Ivar's standalone restaurant and (3) Retail variety/establishment buildings. Per FWRC 19.225.020, retail variety buildings in the City Center Core require 1 parking space for every 300 sf of gross floor area. The combined floor area of the (3) retail buildings is 66,000 sf, which requires 220 parking spaces. With the additional 24 parking spaces for Ivar's, the lot requires 244 parking spaces to support all (4) buildings. The property lot currently provides 356 parking spaces which exceeds the amount required by the Federal Way Revised Code. now Public Works - Development Services Division, Ann Dower 1. The project as proposed does not trigger site development improvements. In the event that other department requirements result in adding, removing, or replacing impervious surface, then additional permits or information may be required. Response: Currently there are no department requirements that will require us to alter the impervious surface around the project area. If this changes, we will notify the Development Services Division to determine any additional requirements. Public Works — Traffic Division, Sarady Long 1. The proposed tenant improvement and expansion of the existing restaurant by approximately 472 square feet is expected to generate net new PM peak hour trips. As such, the applicant will need to submit a concurrency permit application (see the enclosed application) along with the $1,721 application fee and traffic impact fee prior to building permit issuance or TI approval. Based on the current impact rate, the estimate fee is $5,876.75 (see enclosed TIF calculation). Response: A traffic concurrency review application and application fee is included with this resubmittal package. The traffic impact fee will be provided prior to permit approval as noted above. Lakehaven Water and Sewer District, Brian Ashbury 1. Lakehaven has no comment on this application/project, as based on the submittal it appears no existing and/or future Lakehaven water/sewer system facilities will be required, desired, or affected by the proposed land use action. Existing water and/or sewer service connections should be protected during construction (see enclosed sewer service record, SSCP 10072). Any sewer service work outside of a building requires a Lakehaven Sewer Service Connection Permit. If any water or sewer utility conflicts are encountered, the applicant should promptly contact Lakehaven for additional information. Response: At this point, we do not expect any sewer service work to occur outside of the building. Two project notes have been added to the site plan: 1) Protect all existing water and/or sewer service connections during construction, 2) Contact Lakehaven Water and Sewer if any water or sewer utility conflicts are encountered during construction. CC9mmunity Development — Building Division, Greg Kirk 1. The structure will be treated as a new building permit application and must meet all current codes, including: • International Building Code (IBC), 2015 Washington State Amendments WAC 51-50 • International Mechanical Code (IMC), 2015 Washington State Amendments WAC 51-52 • Uniform Plumbing Code (UPC), 2015 Washington State Amendments WAC 51-56 & 57 • International Fire Code (IFC), 2015 Washington State Amendments WAC 51-54 • National Electric Code (NEC), 2014 ■ Accessibility Code (ICC/ANSI A117.1), 2009 • Washington State Energy Code (WSEC), 2015 WAC 51-11 Response: The codes listed above have been added to project cover sheet G101 under the "Code Summary" section. 2. Building Criteria. The following applies to the proposed structure. Please include in your permit submittals: • Occupancy Classification • Type of Construction • Floor Area • Number of Stories • Fire Protection ■ Wind/Seismic: Basic Wind Speed 85 mph, Exposure B, 25-pound Snow Load, Seismic Zone D- 1 Response: The information requested above will be included in the building permit set when it is submitted to the city. If you have any questions regarding this project, please contact me at (206) 962-6616. Thank you, har" Joy Dayaw, RA Associate ' -J!1� -z �Ola 0, 5 DESIGNED ENERGY EFFICIENT — TERRA COTTA AGED COPPER COLONIAL RED PATINA GREEN 'REGAL RED 'HEMLOCK GREEN f BURGUNDY *HARTFORD GREEN I MATTE BLACK EVERGREEN ISOLAR WHITE _4L I SANDSTONE 11 -. REGAL WHITE ASH GRAY STONE WHITE DOVE GRAY SURREY BEIGE SIERRA TAN MEDIUM BRONZE SLATE BLUE SLATE GRAY MANSARD BROWN i 'REGAL BLUE CHARCOAL GRAY DARK BRONZE i 'SILVER COPPER "CHAMPAGNE PRE -WEATHERED GALVALUME'• gip... k Hjj°A_ COLORS 'GALV-TEN'" RAW 'COPPER -TEN" RAW COR-TEN AZP° RAW kl��`kJ PAINTED 6us ACRYLIC COATED GALVALUME MEDITERRANEAN BLUE/ CANVAS BLOCK STRIPE AWNING PAINTED CORRUGATED METAL SIDING EXTERIOR PAINT EXTERIOR PAINT SW 7562 - ROMAN COLUMN SW 6230 - RAINSTORM SHERWIN WILLIAMS SHERWIN WILLIAMS SOUTH ELEVATION - EXTERIOR COLORS AND MATERIALS IVAR'S SEAFOOD BAR - FEDERAL WAY 12/20/19 APPROVED PLANNING City of Federal Way ►ept. of Community Development 'ermit fq - 1d11ZL- - aP I<y ;ir""Qm G�Id,h )ate EXTERIOR PAINT SW 6488 - GRAND CANAL SHERWIN WILLIAMS LU J Li. Uj UL RESUBMI'n-EC DEC 2 3 2019 Cm{ QF FEDERAL WAY COMMUN rY Q£VEL0P,mEw Since 1938 ANON )"164 z'�Ioww rW MEDITERRANEAN BLUE/ CANVAS BLOCK STRIPE AWNING PAINTED CORRUGATED METAL SIDING EXTERIOR PAINT SW 7562 - ROMAN COLUMN SHERWIN WILLIAMS EAST ELEVATION - EXTERIOR COLORS AND (MATERIALS IVAR'S SEAFOOD BAR - FEDERAL WAY 12/20/19 EXTERIOR PAINT SW 6230 - RAINSTORM SHERWIN WILLIAMS EXTERIOR PAINT SW 6488 - GRAND CANAL SHERWIN WILLIAMS 'SSiin�ce 1936 VWY1�I w J si RECEIVED MG2 Corporation 1101 Second Ave, Ste 100 2019 206 962 6500 Seattle. WA 98101 SEP MG2.com CfTY OF FEDERAL WAY COMMUN" I7EVELOPf ENT September 9, 2019 City of Federal Way - Community Development Department Cc: Ivar's, Inc. Re: Ivar's Seafood Bar 2004 S 320th St Federal Way, WA 98002 Subject: Use Process I - Project Narrative The proposed Tenant Improvement project to the existing Ivar's Seafood Bar includes a 471.5 sq.ft. addition to an existing 1,893 sq.ft. restaurant. This addition is 21.9% of the existing building area which is less than the maximum 25% addition allowed for Use Process I. This scope of work covers an exterior renovation and addition that includes an extension of their existing dining area, extension of existing dining patio, and a new exterior walk-in cooler. We will remove the existing sloped tile roof but maintain the existing roof height and structure, which dates to the initial Arthur Treacher's Fish and Chips built in 1978. By removing the sloped tile roof, the finished renovation will feel more in character with the adjacent plaza buildings that are currently being renovated. The proposed exterior renovation also includes an updated color palette that is present in the recent Ivar's renovations throughout King County. Iconic brand elements will be added to the building exterior such as the white and blue awnings, "Ivar's" lit. signs, and a "Keep Clam" graphic that's been tailored specific to Federal Way. If you have any questions regarding this project, please contact me at (206) 962-6616. Thank you, Joy Dayaw, RA Associate him RECEIVED SEP 12 2019 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT CITY OF 72 -IL if &-- A-- aila-a7z III alli, co � �eg MASTER LAND USE APPLICATION DEPARTMENT OF ComzouNITX DEVELOPMENT 33325 St" Avenue South Federal Way, WA 98003-6325 253-835-2607; Fax 253-835-2609 u•uz�=. c i [gyp rredc ra i «•: n . rnfs+ APPLICATIONNO(s) + �` / Date °� °► lA Project ].Name Ivar's Seafood Bar Property Address/Location 2 2 th St Federal Way. WA 98003 Parcel Numbers) 092104-9297 Project Description Tenant Improvement to an existing 1,893 s .ft. restaurant buildina includinq a 471.5 sq.ft. addition. Exterior renovation includes new materials, lighting. and signage. rxuv 1 Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Camp Plan/Rezone _ Land Surface Modification Lot Line Elimination Preapplieation Conference X Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV ,(Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) _ Process VI SEPA w/Proj ect SEPA Only _ Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: COmmercial/Residential Required Information CC - Center Core Zoning Designation Commercial Comprehensive Plan Designation Value of Existing Improvements $750,000 Value of Proposed Improvements International Building Code (IBC): A 2 Occupancy Type y'$ Construction Type Applicant Name: Ivar's, Inc. Address. 1001 Alaskan Way, Suite 109 City/State:Seattle, WA Zip: 98104 Phone: Fax: Email: Gary Tobiason: garytt�a Signature: App)icant) Name: MG2'Gorporation/Joy Dayaw Address: 1101 Second Ave, Suite 100 City/State: Seattle, WA zip: 98101 Phone: 206-962-6616 Fax: Email: joy.dayawA.&Alfie g2.com n Signature: � L., Owner " " Name: NWCC Center Plaza, LLC. Address: 1402 E Pike St City/state: Seattle, WA zip: 98122 Phone: Joanna Russell: 206-423-3105 Fax: 1 5 � Email: (1 � G, Signature• V-2 Bulletin #003 —January 1, 2011 Page 1 of 1 kAHandoutslMasterLand Use Application '1 1 CITY CENTER (CC) CITY OF Estimate of Development Traffic Impact Fees Federal Way This spreadsheet is for development in City Center (CC) only. Scroll down and complete the steps outlined below: Please fill in the required information in the highlighted boxes. STEP #1: General Information Entei information Project Name Ivar's Seafood Restaurant File Number 19-104375-UP Street Address 2004 S 320 St City, State Zip Federal Way, WA Parcel Number (s) 092104-9297 STEP #2: Land Use Type (CC) Select the proposed Land Use Type(s) from the dropdown memu below. Enter the proposed number of units for Unit of Number of Impact Fee Rate per Preliminary Impact Proposed Land Use Type (s) Measure Unit(s) Unit of Measure Fee Amount 1) Restaurant (CC) sf/GFA 472 $ 12.09 $ 5,705.59 2) NONE #N/A $ - $ 3) NONE #N/A $ $ 4) NONE #N/A $ $ $ 5,705.59 STEP #3 - Credit/Change in Use (CC) This step applies to development proposal to change existing building or dwelling use. Provide any impact fee previouly paid for the land use category of the prior use IMPACT FEE AMOUNT PAID FOR (Do not include administration fees). PRIOR USE For a change in use of an existing building, the impact fee will be assessed based on the difference between the new uses and the prior use. If no impact fee was required for the prior use, the impact fee for the new use shall be reduced by the amount equal to the current impact fee rate in affect for the prior use. Fill out the lines below of the prior use. Unit of Number of Impact Fee Rate per Preliminary Impact Proposed Land Use Type (s) Measure Unit(s) Unit of Measure Fee Amount 1) NONE #N/A $ $ 2) NONE #N/A 1 $ $ 3) NONE #N/A 1 $ $ STEP #5: Total Impact Fee (CC) Calculate estimated Total Traffic Impact Fee payment amount, including Administrative Fees. Traffic Impact Fee (Before adjustment) $ 5,705.59 Credit/Adjustment including Change of Use Administrative Fee (3%) $ 171.17 ESTIMATE TOTAL TRAFFIC IMPACT FEE PAYMENT $ 5,876.75 19.100.070 - Timing of Fee: Transportation Impact Fee Payments FWRC 19.100.070 3(a) - For commercial developments, fees shall be calculated based on the impact fee schedule in effect at the time a completed building permit application is filed and paid prior to permit issuance. For a change in use for which no building permit is required, the fee shall be calculated and paid based on the impact fee schedule in effect on the date of an approved change of use. FWRC 19.100.070 3(c) - For all applications for single-family, multifamily residential building permits, and manufactured home permits, the total amount of the impact fees shall be assessed and collected from the applicant when the building permit is issued, using the fee schedule then in effect. 19.100.075 » Option for Deferred Payment of Transportation kn act Fee An applicant may request, at any time prior to building permit issuance, and consistent with the requirements of this section, to defer to final building inspection the payment of a transportation impact fee for a single-family residential dwelling unit. Refer to defer payment of impact fee code for process. Proposed Land Use Type (s) 1) NONE 2) NONE 3) 1 NONE Unit of Measure #N/A #N/A #N/A Number of Unit(s) 1] $ 0 9 $ Impact Fee Rate per Preliminary Impact STEP #5: Total Impact Fee (CC) Calculate estimated Total Traffic Impact Fee payment amount, including Administrative Fees. Traffic Impact Fee (Before adjustment) $ Credit/Adjustment including Change of Use $ Administrative Fee (3%) $ ESTIMATE TOTAL TRAFFIC IMPACT FEE PAYMENT $ 2,124.30 63.73 2,188.03 19.100.070 - Timing of Fee: Transportation Impact Fee Payments FWRC 19.100.070 3(a) - For commercial developments, fees shall be calculated based on the impact fee schedule in effect at the time a completed building permit application is filed and paid prior to permit issuance. For a change in use for which no building permit is required, the fee shall be calculated and paid based on the impact fee schedule in effect on the date of an approved change of use. FWRC 19.100.070 3(c) - For all applications for single-family, multifamily residential building permits, and manufactured home permits, the total amount of the impact fees shall be assessed and collected from the applicant when the building permit is issued, using the fee schedule then in effect. 19.100.075 - Option for Deferred Payment of Transportation Impact Fee An applicant may request, at any time prior to building permit issuance, and consistent with the requirements of this section, to defer to final building inspection the payment of a transportation impact fee for a single-family residential dwelling unit. Refer to defer payment of impact fee code for process. CITY CENTER (CC) AN CITY OF Estimate of Development Traffic Impact Fees Federal Way This spreadsheet is for development in City Center (CC) only. Scroll down and complete the steps outlined below: Please fill in the required information in the highlighted boxes. STEP #1: General Information Enter Information Project Name File Number Street Address City, State Zip Ivar's Seafoof Bar 19-104375-U P 2004 S 320 St Federal Wav, WA Parcel Number (s) 092104-9297 STEP #2: Land Use Type (CC) Select the proposed Land Use Type(s) from the dropdown memu below. Enter the proposed number of units for Proposed Land Use Type (s) 1) Shopping Center (CC) 2) NONE 3) NONE 4) NONE Unit of Number of Impact Fee Rate per Preliminary Impact Measure Unit(s) Unit of Measure Fee Amount sf/GLA 472 $ 4.50 $ 2,124.30 #N/A $ - $ - #N/A $ $ #N/A $ $ $ 2,124.30 STEP #3 - Credit/Change in Use (CC) This step applies to development proposal to change existing building or dwelling use. Provide any impact fee previouly paid for the land use category of the prior use IMPACT FEE AMOUNT PAID FOR (Do not include administration fees). PRIOR USE For a change in use of an existing building, the impact fee will be assessed based on the difference between the new uses and the prior use. If no impact fee was required for the prior use, the impact fee for the new use shall be reduced by the amount equal to the current impact fee rate in affect for the prior use. Fill out the lines below of the prior use. 10/3/2019 https:Hitetripgen.org/PrintGraph�+ ?code=930&ivlabel=QFQAF&timeperiod=TPSIDE&x=1 89&edition=385&IocationCode=General Urba... Fast Casual Restaurant (930) Vehicle Trip Ends vs: 1000 Sq. Ft. GFA On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Setting/Location: General Urban/Suburban Number of Studies: 15 Avg. 1000 Sq. Ft. GFA: 3 Directional Distribution: 55% entering, 45% exiting Vehicle Trip Generation per 1000 5q. Ft. GFA Average Rate Range of Rates Standard Deviation 14.13 Data Plot and Equation 200 50 5.94 - 34.83 F-4 X X X 27 X X - - � X X 00 1 2 3 4 X = 1000 Sq. Ft. GFA X Study Site Fitted Curve Equation: Not Given Trip Generation Manual, 10th Edition ■ Institute of Transportation Engineers 7.72 5 Average Rate Rz= **** 6 https://itetripgen.org/PrintGra ph. htm?code=930&ivlabel=QFQAF&timeperiod=TPSIDE&x=1.89&edition=385&IocationCod e=General Urban/Suburban&... 1/1 Sarady Long From: Sarady Long Sent: Thursday, October 17, 2019 8:56 AM To: William Golding Cc: Stacey Welsh; Cole Elliott Subject: Ivar's Restaurant Attachments: 2019 FW Concurency Application.pdf, 19-104375-UP Ivars Restaurant.pdf William, The proposed tenant improvement and expansion of the exiting restaurant by approximately 472 square foot is expected to generate net new PM peak hour trips. As such, the applicant will need to submit concurrency permit application (See attached application) along with $1,721 application fee and pay traffic impact fee prior to building permit issuance or TI approval. Based on the current impact rate, the estimated fee is about $5,876.75 (See attached TIF calc). Let me know if you have any questions. Sarady Long Senior Transportation Planning Engineer S, Federal Way Public Works Department 33325 8th Ave S, Federal Way, WA 98003 Desk:253.835.2743 1 Fax:253.835.2709 www.cityoffederalwov.com