03-104925` ciTv of CITY HALL �. Federal Way ay Feder 1 st Way South • -9 Box 9718 Federal Way, WA 98063-9718 (253) 661-4000 www. cityoffederalway. com November 17, 2003 Mr. Norris Bacho 1426 Harvard Avenue, Unit 11 ,- y 9 r Seattle, WA 98122 Re: File No: 03-104925-00-UP; PROCESS I APPROVAL AT&T Wireless Weyerhaeuser; 33930 Weyerhaeuser Way South (Building B, Weyerhaeuser Complex) Dear Mr. Bacho: The City has completed an administrative review of AT&T's project at the above referenced location. The applicant proposes to locate an AT&T Personal Wireless Service Facility (PWSF) on an existing 48-foot tall office building in the Office Park (OP-2) zoning district. Pursuant to Federal Way City Code (FWCC) Section 22-835, PWSFs are reviewed under Process I, when meeting the special regulations listed in Note #2 of this code section. Based on the development regulations identified in FWCC Sections 22-966 through 22-975, the Process I application is hereby approved. The PWSF ground equipment will be screened by an expansion of the existing mechanical screening; the proposed screening will consist of pre -finished black metal siding that is consistent_ with the existing mechanical screening. The PWSF ground equipment consists of four units whose gross floor area is approximately 23.0 square feet. The project consists of a total of 12 panel antennas measuring four feet/three inches in length. The antennas will be mounted on the. mechanical screening as follows: four antennas to be mounted to the existing mechanical screening on the north fagade; four antennas to be mounted to the existing mechanical screening to the west; -and four antennas to be mounted to the proposed mechanical screening to the east. The height of the existing mechanical screens is 55 feet/10 inches. The antennas will be painted to match the mechanical screening, thereby satisfying the development standards of FWCC Section 22-967(1)(a). The applicant shall contact the Planning Division of the Department of Community Development Services for a final inspection of the PWSF. In conjunction with the inspection, the applicant shall submit an affidavit to the Planning Division that verifies the PWSF has been installed in accordance with the approved plans for the application. This application requires the applicant to obtain an electrical permit and building permit from the City of Federal Way before doing any work. Mr. Norris Bacho Page 2 November 17, 2003 This approval does not exempt the project form other local, state, and federal permit requirements. Pursuant to FWCC Section 22-972, within six months of issuance of the permit for the facility, you must submit a project implementation report providing cumulative field measurements of radio frequency (EMF) per densities of all antennas installed at the site. This approval is also subject to five- and ten-year permit limitations identified in FWCC Section 22- 974 (enclosed). The effective date of this decision is November 17, 2003. The decision may be appealed in the form of a letter delivered to the Department of Community Development Services (33530 First Way South, PO Box 9718, Federal Way, WA 98063-9718) by December 1, 2003. An appeal letter must contain a clear reference to the matter being appealed and a statement of the factual findings and conclusions of the Director of Community Development Services disputed by the person filing the appeal, and must include the appeal fee. Any additional requirements of FWCC Section 22-397 must be followed. Pursuant to FWCC Section 22-396, if no appeal is submitted within the 14-calendar day appeal period, the preliminary approval shall become final on the first calendar day following the expiration of the appeal period. Upon the decision becoming final, the applicant may engage in activity based on the decision, provided applicable permits have been approved. In that you are the only party of record for this application, you may waive your right to appeal. The City must receive this waiver in writing. If you choose to waive your right to appeal, you could begin work on the proposal on November 21, 2003, provided you have obtained an electrical permit for the proposal by that date. The total cost for this Process I review is $115.00 (two hours at $57.50 per hour). This balance is subtracted from the $57.50 paid at the time of application, and as such, $57.50 is due at this time. This decision shall not waive compliance with City of Federal Way codes, policies, and standards relating to this development. If you have any questions regarding this decision, please call Jane Gamble, Associate Planner, at 253-661-4120. Sincerely, Kathy gMcClun, Director Department of Community Development Services enc: FWCC Section 22-974 Approved Site Plan c: Jane Gamble, Associate Planner File #03-104925-00-UP Doc I.D. 25211 41 HATFIELD & DAWSON JAnms B. HATFIE_D, PE CONSULTING ELECTRICAL ENGINEERS TEIMHONE BENJAmN R DAwsON III, PE 9500 GREENWOOD AVE. N. (206) 783-9151 THom s M. EcKm, PE SEATTLE, WASHINGTON 98103 FAcsadmE (206) 789-9834 STuHEN S. LOCKWOOD, PE E-mAm DAVID J. PINION, PE hatdaw@hatdaw.com PAUL W. LEONARD, PE CONSULTANT PE ERm C. SwANsoN, EI T MnuRY L. L, HomAs S. GORTON, PE CONSULTANT OAxxURST, NSW AusTRAuA POST -CONSTRUCTION NON -IONIZING ELECTROMAGNETIC FIELD MEASUREMENTS ENGINEERING CERTIFICATION PREPARED FOR CIMGULAR WIRELESS Facility No. SS-81 "WEYERHAEUSER" 33930 WEYERHAEUSER WAY FEDERAL WAY, WASHINGTON OCTOBER 2005 1 INTRODUCTION Hatfield & Dawson Consulting Engineers has been retained by Wireless Facilities, Inc. ('WFI") to evaluate the existing Cingular Wireless "Weyerhaeuser" facility, number SS-81, with antennas atop the roof of an office building at 33930 Weyerhaeuser Way, Federal Way, Washington, for compliance with current Federal Communications Commission (FCC) rules regarding human exposure to radiofrequency (RF) electromagnetic fields (EMFs). The Cingular Wireless facility includes panel antennas flush -mounted to rooftop mechanical screen. Access to the rooftop appears to be restricted, and all of the Cingular antennas appear to be centered approximately 52 feet above ground level. Thus it is unlikely that anyone other than authorized RF workers could approach near enough to any of the existing antennas to cause that person's RF exposure levels to exceed FCC limits. It is expected that exposure conditions in all accessible ground level areas, and inside nearby buildings, due to the RF fields from the Cingular transmitting antennas, in combination with any nearby wireless facilities, are well below the FCC public exposure limits. To verify that the existing Cingular Wireless facility is in compliance with FCC rules regarding human exposure to RF fields, I have performed RF exposure measurements at various ground level locations to determine the exposure conditions that exist in publicly accessible areas near the building. MEASUREMENTS OF EXISTING RF EXPOSURE CONDITIONS NEAR THE BUILDING The RF exposure measurements were performed on October 6, 2005. The measurements took place during a busy weekday afternoon, between approximately 1:00 p.m. and 1:30 p.m., when RF activity is expected to be at or near its highest level. Hatfield & Dawson Consulting Engineers 2 RF EXPOSURE MEASUREMENT EQUIPMENT The exposure measurements were performed using a NARDA Model 8718B Electromagnetic Radiation Survey Meter (S/N 0001) with a NARDA Model B8742D Isotropic Shaped Electric Field Probe (S/N 05003). This meter and probe combination is a broadband instrument which measures power densities over a wide spectrum as required by IEEE Standard C95.3-2002, "IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz " The NARDA RF survey equipment provides an output proportional to the FCC general public (Uncontrolled Environment) maximum permissible exposure (MPE) over a very wide frequency range. The meter/probe combination is sensitive to all RF signals in the frequency range of 300 kHz to 3.0 GHz. Therefore the equipment used during the survey, which has been factory - calibrated within the past twelve months, responded to RF signals from all significant transmitters at or near the Cingular facility. RF EXPOSURE MEASUREMENT METHODOLOGY Measurement procedures were performed in accordance with methods described in OET Bulletin 65, August 1997, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields," IEEE Standard C95.3-2002, "IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz," and NCRP Report No. 119, `A Practical Guide to the Determination of Human Exposure to Radiofrequency Fields." The measurement survey was conducted in accessible outdoor areas near ground level. The survey included the parking lots and walkway between the buildings. Measurements were made during weekday business hours when the Cingular transmitters, and all other nearby transmitters, are expected to be operating at or near full power. Hatfield & Dawson Consulting Engineers 3 During the measurement period, accessible areas were scanned with the measurement probe over an area equivalent to that of the human body (one by two meters). At the locations of the highest RF exposure readings, the probe was moved from close to ground level up to a height of approximately 2 meters (6' 7"). During this procedure, the "Spatial Averaging" feature of the survey meter was activated to capture spatially averaged RF exposure levels in accordance with IEEE Standard C95.3-2002. EXISTING RF EXPOSURE ENVIRONMENT The maximum RF exposure levels due to the combined effects of the various wireless facilities operating on and near the building were found to be well below FCC Public MPE limits. The highest measured exposure level was found to be approximately 0.20% of the Public MPE limit. The location of this measurement was on the walkway between the two buildings, approximately 10 yards southwest of the antennas. All other ground level locations, including the parking lots and building entrances, had measured exposure levels less that 0.20% of the public exposure limit. CONCLUSION Wireless facilities are required to comply with the FCC "Rules & Regulations" CFR 47 §1.1310, Radiofrequency radiation exposure limits. Compliance is determined by comparing RF field measurements and predictions with the general population/uncontrolled environment (i.e., "Public") Maximum Permissible Exposure limits (MPEs) allowed by the FCC rules, as specified in CFR 47 § 1.1310. Based on RF exposure measurements, the existing Cingular Wireless facility operating from the building at 33930 Weyerhaeuser Way, Federal Way, Washington, is in compliance with current FCC rules regarding human exposure to radiofrequency electromagnetic fields. Hatfield & Dawson Consulting Engineers 4 This conclusion is based solely on the comparison of measured RF exposure conditions in specific areas with the corresponding safe exposure limits set forth in the FCC rules. The FCC exposure limits are based on recommendations by federal and private entities with the appropriate expertise in human safety issues. INTERFERENCE The transmission equipment for the Cingular Wireless facility is certified by the FCC under the equipment authorization procedures set forth in Part 2 of the FCC rules. This assures that the wireless facility will operate only within the desired cellular and PCS frequency bands, and that spurious emissions are within FCC specifications. Thus the existing Cingular Wireless facility is unlikely to interfere with the reception of area television or radio broadcasts, other adjacent or neighboring transmission or reception functions, or the functioning of any other electronic devices. QUALIFICATIONS I am an experienced radio engineer whose qualifications are a matter of record with the Federal Communications Commission. I am a partner in the firm of Hatfield & Dawson Consulting Engineers and I am registered as a Professional Engineer in the States of Washington, Oregon and California, and I hold an FCC General Radiotelephone Operator License PG-12-21740. All representations contained herein are true to the best of my knowledge. 7 October 2005 David J. Pinion, P.E. .k��S LE?4P RRES 11/27 Hatfield & Dawson Consulting Engineers R E L C O III October 18, 2005 Mr. Riley Pittman Planning Intern City of Federal Way City Hall PO Box 9718 Federal Way, WA 98063-9718 RE: Cingular Wireless EMF testing requirements Dear W. Pittman, C0N[MUNlTI'RFVCElVED BY F-LOPt4ENT DEPARTb9ENT OCT 2 0 2005 Pursuant to Federal Way City Code Section 22-972, requiring the submittal of a project implementation report that provides cumulative field measurements of radio frequency (EMT) power densities of all antennas installed at the subject site, please find the attached reports for the following sites: Site # Site Name Permit # Description SS40 Aqua Center 01-101027-UP 650 SW Cam us Drive, BPA tower. 1741 South 356th Street, Existing Lattice $S70 Enchanted Parkway 02-101654-UP Tower 2101 South 324th Street, Belmor Park SS67 Federal Way 02-101491-UP exisitng mono loe dz- IOSZY7-VP Right-of-way at 150 feet east of 47th t2—W&4WJ-UP & Avenue SW and SW Dash Point Road, SS65 Dumas Bay 04-100088-UP PSE pole Right-of-way at 2650 SW Dash Point SS_6_4 Lakota 02-104989-UP Road. PSE pole Right-of-way at 1232 SW Dash Point SS63 Grace Church/PSE 02-105221-UP Road, PSE pole 34301 9th Avenue South, 20-foot WA-415-1 Tammy Lane 03-102487-UP extension to an existing monopole Federal Way 29205 18th Avenue South, existing SS36 I Redondo 03-010281-UP monopole 33930 Weyerhauser Way South, roof of SS81 Weyerhaeuser 03-104925-UP existing office bldg _ 28405 Military Road South, Lakehaven WA-876-1 South 288th Street .04-102951-UP water tank WA-462-04 Adelaide 04-104689-UP 31119 21st Place SW, existing utility ole g7-104039-OOR-00- SSO4 Federal Way UP Kn 1628 S.344th Street 98-103386-000-00- SS19 Mirror Lake UP 31617 1st Avenue S Please feel free to call me with any questions or concerns at 206-817-4689. Sincerely, Rod Hanson Representing Cingular Wireless REALCOM Associates, LLC • 3245 —146t' Place SE, Suite 320, Bellevue, WA 98007 — PA25-274 4444; f:425-274- 449 Nov 14 03 10:00a p.l �l AULT October 21, 2003 Jane Gamble Planning Department City of Federal Way 33530 l" Way South P.O. Box 9718 Federal Way, WA 98063-9718 Re: Purpose of this communications facility and height requirement Dear Ms. Gamble: The main purpose of the proposed AT&T Wireless cellular and PCS communications facility at 33940 Weyerhaeuser Way S, Federal Way, WA 98001 is to provide improved coverage in Federal Way along Hwy 18, and in particular, close to the intersection of Hwy 18 and Weyerhaeuser Way S. In order to improve coverage enough in this area, the minimum height required for our antennas on the roof of this building is 55 ft. Our antennas have to be high enough to connect our current sites Federal Way (roughly 1.1 miles away) and Peasley Canyon (about 0.7 miles away) along Hwy 18. We continue to try to improve coverage for our customers in Federal Way and we know that lack of coverage is a problem in this area. Our proposed site, SS81 Weyerhaeuser, is to address this problem. If you have any further questions, please contact me at 425-702-3987 or at leo.viray@athvs.com. Sincerely, �J U J-r�fi�ii � LY Y Leo Viray AT&T Wireless Radio Frequency Engineer b Recycled Paper Nov 14 03 10:00a p.2 c r z 3 .+ C Q) C ul N m C C L v m U J Y m m L O IL O O 3 3 N In ID m T o L N N nr mO m m¢I N QI +/ N N D D O D m-of O w — O C m¢❑ > m o m 0 o t o „ D 10 T z 10 r O D c N a) 0 L L i 3 N m O_ T 1p O ,y y a " 4J L m C L L C Url m m C O E 771 41 O O +1 r+ L 0 L1 . C U m G m L m m m L m U E C m U f 4� z 1Z�F— J— ULn o I I l I Nov 14 03 10e01a p.3 Z ti m rn C N C h C V a fo m J m L O ❑ O > 3 3 N l0 Y C N Ul V O OI N Z O m �, O L N VI N N (!I .� N (NJ D O O �I LO LO • v 7 NN C ro ❑ mr\ m- Ol al 0 7 U 0 O I I i 4 O N •• QI O m C[ T L „ L O ti in L c N 9 0 T ILO o m in to to f O T J y y L f 0 C L-0 m m r Y C U 3 ITI CD C❑ E O ❑1 I 1 a)O O O L Ul O 10 L LLl N❑ U M O. U7 Z C II II II L G1 m N G m QI /� A Aa�� � � rri e I � � � in . -M Nov 14 03 10:01a p.4 z ti rn of C T N C C h C ❑ V O UI +i O L 0 o J xm n L O C 010 D� 3 3 N (O w m z cq z + m `0 L N T O E U N U L N,w (U [n N m ❑ ti N D O O V I.n In m of m o c m¢ a I > m o o a o l o— L L O 10 Q T L Y CN9 . I L L Y E N Ol O T f0 O lf7 1f7 Ui ❑ T J T L O �m01m 1� ,..� 11 N " J-� L �0 C L l+ C U :Zr m N C O E D t UJ 0 0 O L N 7 .•• .ti U. •--� O 0 L 0] (D �UO_[nZ rnA A A afF- rmno - ) e in Nov 14 03 10:01a p.5 Z 0 C N N C L h C O V m n L a o, m J C- m m L O Z O O 3 3 N D (p + C CU D m m m Cl) Z ti m T ❑ L N E l 4 inN U1 N 7 N N D D O DI D U7 LO m QI N ey O C mcr, O �r, > 61 O lO 7 D c) I O -• I L L pl cl❑ ID � T L Y U E3N N ON T 9¢ILD C-0 O OLD LO IC] L7 T J mOl O7 I� +� C U _ c O E 0 OI I I I N O O O L UI O .•� .n U -.l •� C U .y .ti y� O T L 01 QI f0 L a)0.] N C m U E - n Z OI A h A U) uM i I 1 I I co Nov 14 Oa 10:01a R -G � @ L k § J § k § k ) k k�En ; £ 00 q ; k� 2) 2 ca §0 /§ - /§ m £ M. k § 2 J k 2 N m � j / t fu J (9 to / ) § — / m 3m cd ; ) \ / k G \ o e = < k a ..]L }\ — 0 k = e f 0 I cm — } / k §0�kk / ) z o z 2 0§1 Im � ƒ � p £ � _ � 13 /c, U.0 , Q }\ )sIL m2 / t Wit» . G 2/§/ 2� § 2 7 ( § / e £ G at— k* £ 13 3 Q G , IV _ R ] m ƒ ƒ enJ &9 2 m ) ] m 2 ) R R R 2 2 ) ! / §� § § § Q / \ 4 k G Q } m I }\ƒdi ~ k k k 2 m {2 k m �) to § § ) ) ) ) \ 2 ) LL 0- 93 0 Nov 14 03 10:01a p.7 U a E o0 0 W a � d E Y y a `m O R a 3 v v R a � c e m � N a a M M � o 0 d o Q S z 0 z d Q N N # U � t � r d w n x K U J J O d m m Q Q in n n pOj m N N N ILL o LL 0 U c 'Em Q � m U U` H U) (n ro m 0 3 0Li 0 C ca C C d N U d _ C C E R O rn n n o 3 v 3 0 —d b Q y U o sn I C R R y d J N W cc O Y Y O .0 L N � O O C d 9 _m F z z F U H S S O N a72 . 9 I� r a C iL o 0 �n Y r a a ,r; a O T -a LL o r R Y ao z T >Q> N to d CD3 —0 0 C a,O Ca O C O In O R N P7 O. d M L CO O O N N n 0 N N C C ,� O C N O O O Q n W v 7 2 2 U N d d 7 d .N M O N N d N a> d O a d N -0 a O z o d O N O d Q co Vl J J m Ir fn L � C U, n n R CR m z z O N O O A 0 U a l . L _ m cq 'd m O O � N CI N C% d N X X N x N x N Q N N C R m N N u 3 LL 0 0. � H G 0 N N k _ a d I E 0 E 0 7 0 m m C _ u C >m m rn i °o 2t_7a R O C Q [a cD C C � d O 0 O 1= � V F LL Q m U c IL 3 E • d .N 4 J a N "N o d O N 00 O N v N O) 0 � R O 0 m � a � m � co cp d L Q 0 N 01 a U T d at Z J CO cc 8 � C N O. N .-a Y uo'i aDi d E LO RO b Y Q 7 D 0 N .•�..• d c > c 'a) - a c a;E w L 6 O a d 0 0 Nov 14 Oa lO:Ola r.8 .r .� LU; � uj \ k§] ; 0/ , R A 2 m m m � \0 ° 2§ , f2 0 CL % k ) ) � fm x ) ] § ] G kk 2 § R d § k ( k ( co\ \ { o & ca f ) { ] # ] s / 2 C ; - - - / / fL / \ C.) 22 k)�k1 ) / 2 2 ■2_ � ƒ \ � 2 f // \ cok {& k$ cz - ° � r / § / j f c" § ) J - & / 8 {/ 22 0e 22 | Q 2 - k ƒ < § « _ Enƒ 5 j 2 2 /U. ] R k 2 2 § \ R 2 d % m / to x k & / \ } § ) \ �\LL { � \ j j j k §}� - fk �\ m ( 7 ( Lol k � § § j 7 J o Nov 14 03 10:02a p.9 A� W N CD C a a v+ of cv ry w I(] N N m O O O m O � 4 � a V V. a`r 0 3 a M n M m a C O i N tO t0 ;a m N O x N N N r- Q 0 Z o 0 0 m H C C C Q 2 Z Z ZO N # U p O � C J y o 0 0 m 0 U m c)_ m o� R t LL O O U7 N a� N d N U U F ¢ N N m O — `3 0 0 c � v N ¢ N 17 N W L' 0 G 7 N n- — G 3 o a 0. m o m o 3' 0 0 > C.)o m w 0 0 y m m c U N a s ` � O J L L v w Z w H Z H G oa o 0 0 " v i❑ T m � O a O O O M 12 I coo N a a C6 �2 LL a cN pM m ¢ CL n w Z T m V N r m M N d °� j C N O O O n m cD M O o 0 U O d C �"' N h N u0i N p`� o .O M N M o M O� ¢ n n n U u- >(n Y ai `y � a N E n n N O C F N N o `o Z .O .-• Q U Y = C m O m a m U fn u) J J m d' co C w n n n 0 LD Ra o M 0 N N O M O N O 0 IL �L •-y a_ i0 �0 ui N N x M U x M N X [o x N X M (D x c ¢ m M m M m c m m 2 S 2 G of 7 6 i C5 O D) O O O) 0 O QJ 7 N Ll 0 N N N a c a G! F- E 0 E O E O e � m m m C Gf fD t0 tp u f' ❑ m N u] Lq w Y] u1 m m m = m c v U o �n 0 Ln 0 d O U CD QG n N .7 U O O w � O C G i 1O Q Q a N LL a m Nov 14 03 10:02a P. 10 •L c W a ELU m m o � m m d N N (7 N ui i Y V < O V m °1 E m n 3 m v v v aa IYO `m 1.3 o cm o to. 0 3 �o R a, c a: .00 ¢ R N O x N N N O a" = N N N � c R � O N c c R R ¢] In m m m m a oo 0 o o a Z Z Z N N N O L N N 4k U L C w In r n J d N N N x w O U J J O a a N � m fn r n r OOj m N R R R � LL Q 0 U U _ H R R O m 3 _ O C O R N - it Q C j � C U C C a h d c r E R o a a 0 c 0 0 `o o Er a 0. U o C (0 w Y > {D GI � 0 z°z° Ol O) �c0i1ws2 a�i m o0 0 r r 0 0 ° 00 0 N M V a R w 0 d a � D [7 10 ri m N m J O O z T R O C R U N or N N c d C o 0 0 O O O fV (V N cl) m N N ^ N c rn O O C IL c ZE m X ..L N d a N w a Q O 7 Q IO U fn fn J J 0 (D 2' fn LL E N r r r 3 o n r n � J = m z ❑ m z z O N 0 O O O a L I= •y .O m O m O In O C N N p x cl x N (7 x 10 x li ) N Eli x u7 x U, s C R m N N N c 0 o m 0 m 0 CD tr lL 7 � N N N * C Q v E E E C o o m 0 m u u Q �_ o 0 0 > in 2 m S J C M O O rn I.^. R m PJ C] tj R C 0 O O Is r r n ID � C (7 C C C 1^ W W O O O C I= � _ GI w `o adi w O N O O LL7 ti N a R 3 m � R O vi v :3 m _ co 3 E CD CV N [) O O (V O O � O N co y O v IA C 7 N — R L O O O 3 O m ('M ¢ N n m V co 0) W N [O Q Nov 14 03 10:02a 90 � v caii b !o uWi a^ o 0 0 0 a �+ N W W W rn a y o 0 0 0 'D 3Ill rL a v a v d <L r e o In m O M a n m a c Q 10 N 0 x N N N N ft]a CI a T m v �. m b F m N m N m N 0 LLgLLa Z Y Y Y z z z d # U rn C J N YOi YO'! O O U J (�ED N o U Q Q N m V) o0 m m m co c c U O O 0 U m N c (7) 0 HZ) Z m m D � 3 O O C N N N a c C 6f Z' 7 C C r E .. R O G/ a C C d T cn U c c 0 'o o w O 0 ; S fn W 3 O y d 0- •0 C u 10 N Y Y J y y 3 t L N a N z z al O) H U 2 2 C Q= w o 0 0 0 m 0 0 0 0 vao m LL N [A o r n rn r TO m m D o a m c o v N O i f0 W 0 7 O C C m O O o 0 0 O� C Zo W N Cfx `O•' � n ti !n 3 L N C N N O O O c O N N O b y 0 CL O z 'O) 0 E �a.. Q cOi Gl of = C N O N ftl Q m U � UI fn 0i O J 7 O LL J � z z m o m z z O N y o h O N O U C o > a c iL D7 N C, m m m A v v v c W N iq a x m � u� ch x Cfl ea LQ c, x f0 cd o x N x C Q � iCl � � b C !0 m 2 2 N = u c o 0 0 0 u 0�1 0 U. 7 � CL N N N k C O _ a GI CL F E 0 E 0 E 0 E 0 0 m m m m C NC '�'• o 0 0 0 u o O � o m m O tO !O O c GI o 0 0 li o O 9 W b O N N N ,z Q p Q n h n !1 O, C V C C C L Q a U. Q f0 U 7 0 PB Architects Seattle Structural Calculations V�ecs.Nso AT&T 011y or PtEptil?A! NAY utLplNC� UE��' Weyerhaeuser (SS81) 33930 WEYERHAEUSER WAY S FEDERAL WAY, WA. 98001 - -- EXPIRESai �-) PB ARCHITECTS SEATTLE_ I 303 BATTERY STREU SEATTLF, WASHINGTON 98M ® (206) 443-9790 fa (206) 443-9075 NeL,) W iii Cf New cop 4 =4 I PB ARCMECTS SUM PROJECT: V DESIGNED: PROJECT Scl-f ��E E 'G" D' CLIENT: CHECKED: DATE: APPROVED: T&Saw= _ SHEET: E EET: ) 43 ( (2G64-9875 a - �� �, 2 3 9790 ylk ,L. 58e PROJECT: [{}Q r rj [ts DESIGNED: Pb PROJECTt l0k �3�pI7�9 CLIENT:..�� CHECKED: DATE: Oj Q APPROVED: ax, arruuc�_asurru� — - - B) 459-9796 SHEET: B) f49-9B76 I Y�,�x .pf t- �(qj 3�• 3 1S6tox�t�� IF 76 6`- 2ax- rs�II.t7�. �tS C�el6- v 17 �/j24x�-c pg r�s PROJECT:[i1IL�C-r CLIENT: -7 �s�p�Y sraar 58A:'t» �I�iGTW+ us:xs (206):449-9790 - �z (200) 4497:9076 . �._.'_ Mtn x Iz+ Ire - / s- IDESIGNED: �Y CHECKED: APPROVED: PROJECT # Zl (76 DATE:03 SHEET: r Ts r Q � 6. 0 6 e T7 12 � tf C�- - 4 /( S Pe -t 4�1- 2-4 -it) V 4 4.5 � � 1g�73 — r�� 7� 4 2- 6 C© 29 6 .4 r, PROJECT:. CLIENT: /1--Fc5 7— 4s sirrffiir f MM sacs Eh) ry(208) 449-9790 . 1] (208) 44979876 y DESIGNED: 106 CHECKED: APPROVED: PROJECT 23 (176 DATE: SHEET: 3 �. b rr i P f. 2 .X- 0 4 a :7 Z.. 77 � adz . � -�d.�� Q 4<< - Xr S� — s-• Coco �zc-o PB ARCHMEM SRAT,g PROJECT: RESIGNED: PP. PROJECT #23f !7,6 CLIENT: A 77 CHECKED: DAM APPROVED. w t Qas� (209) 443-0790 SFIEET: �. '� (206) 443-9976 } Ir TIP- f 7-5--6 W=lf-tloz6v 4 kC • rj 47 U = 4 79'�'4� , &RCMUGM.M �' x PROJECT: ��i�?—' 'p-r A4-uSc r CQ Wqve5 DESIGNED: �� PROJECT CLIENT: T CHECKED: DATE: APPROVED: sos tutrssry snexer se► t smtr ae x� ijo (2o6) 443-9790 SHEET: •5 igz (206) 443-79V5 I gIf 7-0 s� . cc_ �C Tp ) 7 C Y z 70 III Pa Agcmcn mnu PROJECT: %U� v�1 f e {— �' y,.�. �[�� DESIGNED: P PROJECT.0 I I r i CLIENT:�- CHECKED: DATE: APPROVED: a� tn91 a xL9mL eti a pia (206) 443-a�so 5xEET: C F,6 ' P 2 2 K 4 �-4 T� y v e� 4 t h j 40<6 = 24d W R i>sk G� 17 33 r--4'f - I �'-f s f 4 m®o = s s j f Ls l 7 } Q �1-�x(7 f� 37CSC IDr�p� pla am PROJECT: w,2 +f �L Z Y�( y(�{ C DESIGNED: PROJECT 23� :�/ CLIENT:kTx CHECKED: DATE: ����� APPROVED: a9 ate S3xy.3. Hi'SlliCYOH SE123 b (206) 443-9790 SHEET: (266) 443-9875 E- f I f _ f , 7.2 1 r `T JPl e-glr hl�QrQt`r q � 0� q. °✓�f �79, 1 I25 �g� 0✓2 T � €k� 70� : ( 1 1 1 W� —274'-' 1�5 W3 PB cmcss TTLR PROJECT: �/(J- f� r y� �z� 14 r CC? �`r c� f' DESIGNED: CLIENT. CHECKED: ' APPROVED: dS 87SYnymSdA i !1 33121 p (206) 443-9790 D (208) 44879875 PROJECT��j� DATE: eC619, U41 SHEET: V� C2 7d x = s-r 2 cl S�- c r r. 4 CIL r d 00 k, p PH AR SEATTLE PROJECT:./W.� Co-M $ DESIGNED: t°- _ PROJEC-f i I i CLIENT: T CHECKED: DATE: APPROVED: () 443—P7ao- - - ----- - SHEET: 9 206 (206) 443—DB75 !2 1 k��=330 �z= 240 t (rt r• t i _ f � PAr tLZ3 22.4�'_l2x/ 27,3? 3�. 4.1 9 24 J `S- ij!_B: ►u�c�rrscrs PROJECT: f C-4Pu CLIENT: AI cis' r - 0 i - lu PA2Y UM MUM i.14i13l L p$lal V (205) 443-9790 DR (206) 443-9875 .� DESIGNED:' PROJECT CHECKED: DATE: APPROVED: SHEET: r� �U0 P - G� Gf Ii y� .F o 3�do- rc pg CMTEC S S&MU PROJECT: k, + 2<-/- Cg DESIGNED: P PROJECT CLIENT: /-T�f CHECKED: DATE: o APPROVED: - SOS Si $f3r�f �i;l� 7A�i'G70N PA12f =SHEET' f (206) h'3-9790 f0(208) 449-9875 "RQ VtP e p I't �� L, t- 7g�©D 4-1 4 r Cam`) L k r�� �r4CrF. u Q d�iL CL 5, rs care PROJECT: ��. Ce H-t - CLIENT: w:�s CJ (2GB):443-9790 Dxx (208) 44379875 DESIGNED. Pg CHECKED: APPROVED: PROJECT #231 (7.6 DATE SHEET: r3 0.1 Loads: BLC 2, Results for LC 2, Oppos. Wind Reaction units are k and k-ft PB Architects, Inc. P.S. Peter Bolotski Screen Wall 4 October 8, 2003 3:46 PM Enclosure 9 high 6ft.r3d Company PB Architects, Inc. P.S. October 8, 2003 Designer Peter Bolotski 3:46 PM Job Number: Screen Wall Checked By: Joint Coordinates Joint Label X Coordinate Y Coordinate Z Coordinate Joint Temperature Detach from MN !Hl 14'k 1G% rlianhranm N1 0 1 0 1 0 0 No N2 6 1 0 0 0 No N3 1 0 2 0 0 No N4 0 6 0 0 No N5• 0 9 0 1 0 1 No Materials General Material Label Young's Modulus Shear Modulus Poisson's Thermal Coef. Weight Density Yield Stress STL46 1 29000 1 11154 1 .3 I _ .65 1 .49 1 46 STL36 1 29000 ' 11154 1 .3 ! .65 1 .49 1 36 Sections Section Database Material Area SA(yy) SA(zz) I y-y I Z-Z J (Torsion) T/C Label Shape Label in "2 in"4 in^4 in"4 Onl SEC1 TU4X4X4 STL46 3.59 1.2 1.2 8.22 1 8.22 1 13.5 S2 1 L4X4X6 I STL36 1 2.86 1 1.2 1 1.2 1 4.36 1 4.36 L .141. Member Data X-Axis Shape / Material Phys End Releases End Offsets Inactive Member Label I Joint J Joint K Joint Rotate Section Set Memb I -End J-End I -End J-End Code Length i,4- ,­ce+ -MRA wr vti w7 nrr (in) tin) fftl M1 N1 SEC1 I STL46 Y 2 M2 N3 N4 I i SEC1 I STL46 Y 1 4 _M3 _ N4 M4 i N4 N5 I I SE STL46 Y 1 _ 3 N2 S2 STL36 YI BenPIN I BenPIN 8.485 Joint LoadslBnforced Displacements, Category: None BLC 1 :Wind Joint Label - [L]oad,[M]ass,or Direction Magnitude Joint LoadslEnforced Displacements, Category: None BLC 2: Joint Label [L]oad,[M]ass,or Direction Magnitude N5 L X -.67 N3 I L X -.67 Joint Displacements, By Combination _ LC Joint Label X Translation Y Translation Z Translation X Rotation Y Rotation Z Rotation r.-■ Al-.1 /Mriinnal fray AMA 2 N1 0 0 0 0 0 0 2 N2 0 0 0 I 0 0 0 2 N3 .004 0 0 0 0 -3.348e-4 2 1 N4 -.004 0 0 0 0 1.664e-3 2 N5 -.109 1 0 0 0 0 3.485e-3 Reactions, By Combination LC Joint Label X Force 'Y Force Z Force X Moment Y Moment Z Moment (k) (k) (k) (k-ft) (k-ft) (k-ft) RISA-3D Version 4.5b [T:1AT&T - NW\231176 Weyerhaeuser SS81\Enclosure 9 high 6ft.r3d] _ Page 13 Company PB Architects, Inc. P.S. October 8, 2003 Designer Peter Bolotski 3:46 PM Job Number : Screen Wall Checked By: Reactions By Combination, (continued) I r Joint Label X Force Y Force Z Force X Moment Y Moment Z Moment Member Section Forces. By Combination LC Member Label Section Axial Shear y-y Shear z-z Torque Moment y-y Moment z-z n.. /I,l i41 Itr_f41 (k»ft) fk-ftl 2 M 1 1 1 1.261 -.079 0 I 0 0 .199 I 1 2 1.261 -.079 1 0 0 0 1 .277 3 1.261 -.079 1 0 0 0 1 .356 2 M2 1 1.261 .591 0 0 0 .3156 2 1.261 .591 0 0 0 -.827 3 1 1.261 .591 0 0 0 -2.01 2 1 M3 1 1 0 1 -.67 0 0 0 -2.01 1 2 0 -.67 0 0 0 -1,006 3 0 -.67 0 0 0 0 2 M4 1 1 -1.784 0 0 0 I 0 0 2 -1.784 0 1 0 0 0 0 3 1 -1.784 0 1 0 {) 0 0 Member Stresses, By Combination LC Member Label Section Axial Shear y-y Shear z-z Bending y-top Bending y-bot Bending z-top Bending z-bot ei_-M A-11% fL--n ez-;1 !Lail lkeil fksil 2 M1 1 1 .351 -.047 0 -.58 .58 �T.8O9 0 0 2 .351 -.047 f 0 -.809 0 0 _ 3 .351 -.047 0 -1.039 1.0391 0 0 2 1 92 1 .351 1 .355 0 -1.039 1.039 1 0 1 0 2 .351 .355 0 2.415 -2.415 0 0 3 .351 .355 0 5.869 -5.869 D 0 2 M3 1 0 -.402 1 0 5.869 -5.869 0 0 2 0 -.402 0 2.934 -2.93.4 0 0 3 0 -.4021 0 0 0 0 0 2 M4 1 -.624 1 0 1 0 1 0 0 0 0 2 -.624 0 1 0 0 0 0 0 i 3 -.624 0 1 0 0 0 0 0 Member AISC ASD 9th Code Checks By Combination LC Member Label Code Chk Loc Shear Chk Loc Dir ASD Eqn. Message rarer rug 2 M 1 .047 2 .003 0 y H 1-2 2 M2 .206 4 019 0 v H1-2 2 M3 .193 0 .022 0 y H1-2 2 M4 .029 0 .000 0 Code check based on z-z Axial.. Material Takeoff Material Shape Length Weight STL46 I TU4X4X4 1 9 1 .11 RISA-3D Version 4.5b [T:\AT&T - NW\231176 Weyerhaeuser SS81\Enclosure 9 high 6ft.r3d] Page 14 Company PB Architects, Inc. P.S. October 8, 2003 Designer Peter Bolotski 3:47 PM Job Number: Screen Wall Checked By: Joint Coordinates Joint Label X Coordinate Y Coordinate Z Coordinate Joint Temperature Detach from fftl (ft) (ft) f Fl Diaphragm N1 0 0 1 0 0 No N2 6 0 1 0 0 No N3 0 2 0 0 No N4 0 6 0 0 1 No N5 0 9 0 0 L No Materials General Material Label Young's Modulus Shear Modulus Poisson's Thermal Coef. Weight Density Yield Stress ksi ksi Ratio er'1C"5 F k/ft^3��4 STL46 29000 11154 .3 .65 1 .49 STL36 29000 11154 .3 .65 .49 Sections Section Database Material Area SA(yy) SA(zz) I y-y I Z-Z J (Torsion) T/C Label Shape Label (in)112 inAA iO4 in"4 Onl, SEC1 I TU4X4X4 STL46 3.59 1.2 1.2 8.22 1 8.22 1 13.5 132 L4X4X6 1 STL36 2.86 1.2 1.2 4.36 i 4.36 .141 Member Data X-Axis Shape / Material Phys End Releases End Offsets Inactive Member Label I Joint J Joint K Joint Rotate Section Set Memb I -End J-End [-End J-End Code Length de rees Set TDM �n in Joint L.oadslEnforced Displacements, Category: None BLC 1 : Wind Joint Label [L]cad,[M]ass,or Direction Magnitude IDlisplacement _ k, k-ft in rad k's421 t) .. N5 N3 X X 67 .67 Joint LoadslEnforced Displacements, Category: None BLC 2: Joint Label [L]oad,[M]ass,or Direction Magnitude N5 L N3 L Joint Displacements, BZ Combination LC Joint Label X Translation Y Translation Z Translation X Rotation Y Rotation Z Rotation lint fin) fin] fradians) fradlansa [radians] 1 N1 0 0 0 0 0 1 0 1 N2 0 0 0 0 0. 0 1 N3 -.003 0 0 0 0 3.181e-4 1 N4 .005 j 0 0 0 0 -1.712e-3 1 N5 .113 1 0 0 0 0 -3.599e-3 Reactions By Combination LC Joint Label X Force 'Y Force Z Force X Moment Y Moment Z Moment (k) (k) (k) (k-ft) (k-ft) (k-ft) Page 15 RISA-3D Version 4.5bb [T:\AT&T - NW\231176 Weyerhaeuser SS81\Enclosure 9 high 6ft.r3d] Company PB Architects, Inc. P.S. October 8, 2003 Designer Peter Bolotski 3:47 PM Job Number : Screen Wall Checked By: Reactions. By Combination. (continued LC Joint Label X Force Y Force Z Force X Moment Y Moment Z Moment k) (k k k-ft k-ft] _ (k-ft) 1 N 1 -.144 -1.347 0 0 1 0 1 -.136 1 i N2 -1.581 1.54 1 0 0 1 0 0 1 I 1 VIQIA. I - 1. 1 I COG (ft): I X: 1 Member Section Forces By Combination LC Member Label Section Axial Shear y-y Shear z-z Torque Moment y-y Moment z-z It," 11.E 161, IL -AM (Le-fh lk-ftl 1 M1 1 1 1 -1.347 .144 0 1 0 1 0 -.136 2 1 -1.359 .12 1 0 1 0 i 0 1 -.267 3 -1.372 I 0951 0 0 1 0 -.375 1 M2 1 -1.372 1 -.575 1 0 1 0 1 0 -.375 2 -1.396 -.624 0 0 0 .824 3 -1.42 -.673 0 0 0 2.12 1 M3 1 .037 .743 0 I 0 0 2.12 2 1 .01.8 .707 0 0 0 1.032 3 1 0 .67 0 1 0 0 0 1 M4 1 2.031 -_029 0 1 0 0 0 2 2.119 I 0 CI 0 7.044 .044 3 2.207 1 .029 0 0 0 0 Member Stresses BZ Combination LC Member Label Section Axial Shear y-y Shear z-z Bending y-top Bending y-bot Bending z-top Bending z-bot ILc;I flrcil men fkail tk-QA fkRi1 fksil 1 M1 �1 -.375 086 0 .396 -.396 0 0 2 -.379 1 .072 0 1 .781 -.781 0 0 3 -.382 T .057 0 1.094 1 -1.094 0 0 1 M2 1 -.382 1 -.345 0 1 1.094 -.1.094 0 i 0 2 -.389 -.374 0 -2.405 2.405 1 0 0 f 3 -.396 -.404 0 -6.19 1 6.19 1 0 0 1 M3 1 .01 .446 0 -6.19 6.19 0 0 [ 2 ..005 .424 0 -3.015 3.015 0 0 3 0 .402 0 0 0 0 0 1 M4 1 .71 -.023 0 0 0 0 0 2 .741 0 1 0 -.204 .204 -.4 .476 1 3 .772 .023 1 0 0 0 1 0 0 Member AISC ASD 9th Code Checks By Combination LC Member Label Code Chk Loc Shear Chk Lac Dir ASD Eqn. Message ff►l fftl 1 M1 1 .050 2 .005 0 y H2-1 _ _ _I 1 M2 .218 4 1 .022 4 H2-1 ! ; 1 M3 0 1 .024 0 _.204 1 M4 1 .086 8.485 .002 _ 0 yIH1-2 1 - Code check based on z-z Axial.! Material Takeoff Material Shape Length Weight STL46 I TU4X4X4 9 1 .11 _ -- STL36 I L4X4X6 8.485 I .083 RISA-3D Version 4.5b [T:WT&T - NW\231176 Weyerhaeuser SS81\Enclosure 9 high 6ft.r3d] Page 16 L3 LXTRANSNATION September 22, 2003 RealCom Associates, LLC Attn: Rod Hanson 303 Battery Street Seattle, WA 98121 Re: Order No.: 800-10166647 Your Reference No.: SC East Campus Title Officer: John Jones Buyer/Borrower(s): TBD Seller(s): SC East Campus Inc Subject Property: , Federal Way, WA 98023, King County 1c, 9 2003 G! ; Y -PAL WAY BUIL"IN" LEPT Order Summary Thank you for placing this order with Transnation Title Insurance Company. If you need assistance on this file, please contact: John W. Jones (425) 646-8589 johnjones@landam.com Mark S. Niklason (425) 646-8592 mniklason@landam.com Randy McCrory (425) 646-8591 rmccrory@landam.com 1-800-441-7701 Fax: (425) 646-8593 Additional copies have been sent to: Trananation Tide Insurance Company 14450 NE 29th Place, Suite 200, Bellevue, WA 98007 Phone: 800-441-7701 Fax 425-646-8593 Cover Page WA.09.01.00 Issued by COMMITMENT FOR TITLE INSURANCE Transnation Tide Insurance Com an ,f\JRANSNAT10N Transnation Title Insurance Company, an Arizona corporation, herein tailed the Company, for a valuable consideration, hereby commits to issue its policy or policies of title insurance, as identified in Schedule A, in favor of the proposed Insured named in Schedule A, as owner or mortgagee of the estate or interest covered hereby in the land described or referred to in Schedule A, upon payment of the premiums and charges therefor; all subject to the exceptions and conditions and stipulations shown herein, the Exclusions from Coverage, the Schedule B exceptions, and the conditions and stipulations of the policy or policies requested. (See the following pages for printed Exclusions from Coverage and Schedule 6 exceptions contained in various policy forms.) This Commitment shall be effective only when the identity of the proposed Insured and the amount of the policy or policies committed for have been inserted in Schedule A hereof by the Company, either at the time of the issuance of this Commitment or by subsequent endorsement and is subject to the Conditions and Stipulations. This Commitment is preliminary to the issuance of such policy or policies of title insurance and all liability and obligations hereunder shall cease and terminate 180 days after the effective date hereof or when the policy or policies committed for shall issue, whichever first occurs, provided that the failure to issue such policy or policies is not the fault of the Company. NOTE: THE POLICY COMMITTED FOR MAY BE EXAMINED BY INQUIRY AT THE OFFICE WHICH ISSUED THE COMMITMENT, AND A SPECIMEN COPY OF THE POLICY FORM (OR FORMS) REFERRED TO IN THIS COMMITMENT WILL BE FURNISHED PROMPTLY UPON REQUEST. Iq Attest: , . � ALZ Secretary Transnation Title Insurance Company `f 1+Y5��'rF By: rSf►► 16, 1111 y �R1,70H� COMMITMENT CONDITIONS AND STIPULATIONS 1. The term mortgage, when used herein, shall include deed of trust, trust deed, or other security instrument. President 2. If the proposed Insured has or acquires actual knowledge of any defect, lien, encumbrance, adverse claim or other matter affecting the estate or interest or mortgage thereon covered by this Commitment other than those shown in Schedule 6 hereof, and shall fail to disclose such knowledge to the Company in writing, the Company shall be relieved from liability for any loss or damage resulting from any act of reliance hereon to the extent the Company is prejudiced by failure to so disclose such knowledge. If the proposed Insured shall disclose such knowledge to the Company, or if the Company otherwise acquires actual knowledge of any such defect, lien, encumbrance, adverse claim or other matter, the Company at its option may amend Schedule B of this Commitment accordingly, but such amendment shall not relieve the Camp any from Liability previously incurred pursuant to paragraph 3 of these Conditions and Stipulations. 3. Liability of the Company under this Commitment shall be only to the named proposed Insured and such parties included under the definition of Insured in the form of policy or policies committed for and only for actual loss incurred in reliance hereon in undertaking in good faith (a) to comply with the requirements hereof, or (b) to eliminate exceptions shown in Schedule B, or (c) to acquire or create the estate or interest or mortgage thereon covered by this Commitment. In no event shall such liability exceed the amount stated in Schedule A for the policy or policies committed for and such liability is subject to the insuring provisions and Conditions and Stipulations and the Exclusions from Coverage of the form of policy or policies committed for in favor of the proposed Insured which are hereby incorporated by reference and are made a part of this Commitment except as expressly modified herein. 4. Any action or actions or rights of action that the proposed Insured may have or may bring against the Company arising out of the status of the title to the estate or interest or the status of the mortgage thereon covered by this Commitment must be based on and are subject to the provisions of this Commitment. Commitment Cover - WA (Revised 11/02) NF.14.01.01; SC No.: 11727 SCHEDULE OF EXCLUSIONS FROM COVERAGE The matters listed below each policy form are expressly excluded from the coverage of that policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason thereof. AMERICAN LAND TITLE ASSOCIATION LOAN POLICY (10-17-92) The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance or governmental regulation (including but not limited to building and zoning taws, ardinances, or regulations) restricting, regulating, prohibiting or relating to (1) the occupancy, use or enjoyment of Me land; (h) the character, dimensions or location of any improvement now or hereafter erected an the land; (nt) a separation in ownership or a change in the dimensions or area of the land or any parcel of which the land is or was a part; or (v) environmental protection, or the effect of any violation of these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien or encumbrance resulting from a violation or, alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any govemmentai police power not excluded by (a) above, except to the extent that a notice of the exercise thereof or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Rights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the Insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting in no toss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy (except to the extent that this policy insures the priority of the lien of the insured mortgage over any statutory lien for services, labor or material or to the extent insurance is afforded herein as to assessments for street improvements under construction or completed at Date of Policy); or (e) resulting in loss or damage which would not have been sustained if the insured claimant had paid value for the insured mortgage. 4. Unenforceability of the lien of the insured mortgage because of the inability or failure of the insured at Date of Policy, or the inability or failure of any subsequent owner of the indebtedness, to comply with applicable doing business taws of the state in which the land is situated. S. Invalidity or unenforceability of the lien of the insured mortgage, or claim thereof, which arises out of the transaction evidenced by the insured mortgage and is based upon usury or any consumer credit protection or, truth -in -lending law. 6. Any statutory lien for services, tabor or materials (or the claim of priority of any statutory lien for services, labor or materials over the lien of the insured mortgage) arisuhg from an improvement or work related to the land which is contracted for and commenced subsequent to Date of Policy and is not financed in whole er in part by proceeds of the indebtedness secured by the insured mortgage which at Date of Policy the insured has advanced or is obligated to advance. 7. Any claim, which arises out of the transaction creating the interest of the mortgagee insured by this policy, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that is based on; (a) the transaction creating the interest of the insured mortgagee being deemed a fraudulent conveyance or fraudulent transfer; or (b) the subordination of the Interest of the insured mortgagee as a result of the application of the doctrine or equitable subordination; or (c) the transaction creating the Interest of the insured mortgagee being deemed a preferential transfer except where the preferential transfer results from the failure: (i) to timely record the instrument of transfer; or (ii) of such recordation to impart notice to a purchaser for value or a judgment or lien creditor. AMERICAN LAND TITLE ASSOCIATION OWNER'S POLICY (10-17-92) The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance or governmental regulation (including but not limited to building and zoning laws, ordinances, or regulations) restricting, regulating, prohibiting or relating to (i) the occupancy, use or enjoyment of the land; (ii) the character, dimensions or location of any improvement now or hereafter erected on the land; (ui) a separation in ownership or a change in the dimensions or area of the Sand or any parcel of which the land is or was a part; or (iv) environmental protection, or the affect of any violation of these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any govemmental police power riot excluded by (a) above, except to the extern that a notice of the exercise thereof or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Rights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the Insured claimant became an insured under this policy; (c) resulting in no loss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy; or (a) resulting In loss or damage which would not have been sustained if the insured claimant had paid value for the estate or interest insured by this policy. 4. Any claim, which arises out of the transaction vesting in the Insured the estate or interest insured by this policy, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors' rights laws, that is based on: (a) the tranSsactlon creating the estate or interest insured by this policy being deemed a fraudulent conveyance or fraudulent transfer; or (b) the transaction creating the estate or interest insured by this policy being deemed a preferential transfer except where the preferential transfer results from the failure: (i) to timely retorrd the instrument of transfer; or (ii) of such recordation to impart notice to a purchaser for value or a judgment or lien creditor. Commitment Cover - WA (Revised 11/02) SCHEDULE OF EXCLUSIONS FROM COVERAGE (continued) AMERICAN LAND TITLE ASSOCIATION HOMEOWNER'S POLICY OF TITLE INSURANCE FOR A ONE -TO -FOUR FAMILY RESIDENCE (10-17-98) In addition to the Exceptions in Schedule B, You are not insured against loss, costs, attomeys' fees, and expenses resulting from: 1. Governmental police power, and the existence or violation of any law or government regulation. This includes ordinances, laws and regulations concerning: (a) building (b) zoning (c) Land use (d) improvements on the Land (e) Land division (f) environmental protection "Phis Exclusion does not apply to violations or the enforcement of these matters if notice of the violation or enforcement appears in the Public Records at the Policy Date. This Exclusion does not limit the coverage described in Covered Risk 14, 15 16, 17 or 24. 2. The failure of Your existing structures, or any pair of them, to be constructed In accordance with applicable building codes. This Exclusion does not apply to violations of building codes if notice of the violation appears in the Public Records at the Policy Date. 3. The right to take the Land by condemning it, unless: (a) a notice of exercising the right appears in the Public Records at the Polity Date; or (b) the taking happened before the Policy Date and is binding on You if You bought the Land without Knowing of the taking. 4. Risks: (a) that are created, allowed, or agreed to by You, whether or not they appear In the Public records; (b) that are Known to You at the Policy Date, but not to Us, unless they appeared in the Public Records at the Policy Date; (c) that result in no loss to You; or (d) that fast occur after the Policy Date - this does not limit the coverage described in Covered Risk 7, B.d, 22, 23, 24 or 2S. 5. Failure to pay value for Your Title. 6. Lack of a right: (a) to any Land outside the area specifically described and referrers to in paragraph 3 of Schedule A; and (b) in streets, alleys, or waterways that touch the Land. This Exclusion does not Limit the coverage described in Covered Risk 11 or 18. CLTA STANDARD COVERAGE LOAN POLICY 1990 The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of: 1. (a) Any law, ordinance or governmental regulation (including but not limited to building and zoning laws, ordinances, or regulations) restricting, regulating, prohibiting or relating to (i) the occupancy, use or enjoyment of the land; (ii) the character, dimensions or iocetiort of any improvement now or hereafter erected on the land; (m) a separation in ownership or a change in the dimensions or area of the land or any parcel of which the land Is or was a part; or (iv) environmental protection, or the effect of any violation of these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any governmental police power not excluded by (a) above, except to the extent that a notice of the exercise thereof or, a notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. 2. Aights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge. 3. Defects, liens, encumbrances, adverse claims or other matters: (a) whether or not recorded in the public records at Date of Policy, but created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting in no loss or damage to the insured daimant; (d) attaching or created subsequent to Date of Pollcy; or (e) resulting in loss or damage which would not have been sustained if the insured claimant had paid value for the insured mortgage or for the estate or interest insured by this policy. 4. Unenforceabllity of the lien of the Insured mortgage because of the inability or failure of the insured at Date of Policy, or the inability or failure of any subsequent owner of the Indebtedness, to comply with applicable doing business laws of the state in which the land is situated. S. Invalidity or unenforceability of the lien of the insured mortgage, or claim thereof, which arises out of the transaction evidenced by the insured mortgage and is based upon usury or any consumer credit protection or truthtin-lending law. 6_ Any claim, which arises out of the transaction vesting in the insured the estate or interest insured by this policy or the transaction creating the interest of the insured lender, by reason of the operation of federal bankruptcy, state insolvency or similar creditors' rights laws. Commitment Cover - WA (Revised 11/02) SCHEDULE B GENERAL EXCEPTIONS SCHEDULE B EXCEPTIONS APPEARING IN ALTA OWNER'S POLICY - STANDARD COVERAGE AND CLTA STANDARD COVERAGE LOAN POLICY 1. Taxes or assessments which are not now payable or which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the public records; proceedings by a public agency which may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the public records. 2, Any facts, rights, interim or clain45 which are not shown by the public records but which could be ascertained by an inspection of the land or which may be asserted by persons in possession, or claiming to be in possession, thereof. 3. Easements, liens or encumbrances, or claims thereof, which are not shown by the public records. 4. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other farts which a correct survey of the land would disclose, and which are not shown by the public records. S. Any lien, or right to a lien, for labor, material, services or equipment, or for contributions to employee benefit plans, or liens under Workmans' Compensation Acts, not disclosed by the public records. 6. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) Indian treaty or aboriginal rights, including, but not Ilmited to, easements or equitable servitudes; or, (d) water rights, claims or title to water, whether or not the matters excepted under (a), (b), (c) or (d) are shown by the public records. 7. Right of use, control or regulation by the United States of America in the exercise of powers over navigation; any prohibition or limitation on the use, occupancy or improvement of the land resulting from the rights of the public or riparian owners to use any waters which may cover the [and or to use any portion of the land which is now or may formerly have been covered by water. g. Any service, installation, connection, maintenance or construction charges for sewer, water, electricity, or garbage collection or disposal, or other utilrciers unless disclosed as an existing lien by the public records. SCHEDULE B EXCEPTIONS APPEARING IN ALTA OWNER'S POLICY - EXTENDED COVERAGE 1. TbXes or assessments which are not now payable or which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property cr by the public records; proceedings by a public agency which may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the public records. 2. Underground easements, servitudes or installations which are not disclosed by the public records. 3. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Aces authorizing the issuance thereof; (c) Indian treaty or aboriginal rights, including, but not Ihnited to, easements or equitable servitudes; or, (d) water rights, claims or title to water, whether or not the matters excepted under (a), (b), (c) or (d) are shown by the publk records. 4. Right of use, control or regulation by the United States of America in the exercise of powers over navigation; any prohibition or limitation on the use, occupancy or improvement of the land resulting from the rights of the public or riparian owners to use any waters which may cover the [and or to use any portion of the land which is now or may formerly have been covered by water. S. Any service, installation, connection, maintenance or construction charges for sewer, water, electricity, or garbage collection or disposal, or other utilities unless disclosed as an existing Sian by the public records. SCHEDULE B EXCEPTIONS APPEARING IN ALTA LOAN POLICY (10-17-92) and ALTA HOMEOWNER'S POLICY OF TITLE INSURANCE (10-17-98) No general exceptions appear in these policy forms. Commitment Cover - WA (Revised 11/02) 1 RANSNATION COMMITMENT FOR TITLE INSURANCE SCHEDULE A 1. Effective Date: September 22, 2003 at 8:30 AM Commitment No.: 800-10166647 2. Policy or Policies to be issued: Owner's Standard - Short Tenn Rate Proposed Insured: To Be Determined Amount: $60,000.00 Premium: $ 277.00 Tax: $ 24.38 Total: $ 301.38 3. Title to the leasehold estate or interest in the land described or referred to in this Commitment is at the effective date hereof vested in: SC East Campus, Inc., a Delaware Coproration 4. The land referred to in this Commitment is described as follows: See Exhibit A attached hereto. Authorized Signature Commitment for Title Insurance Page 1 of 10 NF.14.02.07; SC No.: 11727 Order No.: 10166647 EXHIBIT A LOT 2 OF EAST CAMPUS CORPORATE PARK PARCEL 3 BINDING SITE PLAN, AS PER PLAT RECORDED IN VOLUME 193 OF PLATS, PAGES 70 THROUGH 74, RECORDS OF KING COUNTY AUDITOR; TOGETHER WITH AN EASEMENT FOR INGRESS AND EGRESS AS GRANTED BY INSTRUMENT RECORDED UNDER RECORDING NO. 20021119003369; SITUATE IN THE CITY OF FEDERAL WAY, COUNTY OF KING, STATE OF WASHINGTON. SCHEDULE B REQUIREMENTS: Instruments necessary to create the estate or interest to be properly executed, delivered and duly filed for record. EXCEPTIONS: Schedule B of the Policy or Policies to be issued will contain exceptions to the following matters unless the same are disposed of to the satisfaction of the Company. A. Standard exceptions set forth on the Commitment Cover. B. Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date the proposed Insured acquires for value of record the estate or interest or mortgage thereon covered by this Commitment. SPECIAL EXCEPTIONS: 1. Real Estate Excise Tax pursuant to the authority of RCW Chapter 82.45 and subsequent amendments thereto. As of the date herein, the tax rate for said property is 1.78%. 2. GENERAL PROPERTY TAXES and SERVICE CHARGES, as follows, together with interest, penalty and statutory foreclosure costs, if any, after delinquency: (1st half delinquent on May 1; 2nd half delinquent on November 1) Tax Account No.: 2154660020 Year Billed Paid Balance 2003 $119,124.94 $59,562.47 $59,562.47 Total amount due, not including interest and penalty: $59,562.47. Levy Code: Assessed Value Land: Assessed Value Improvements: 1205 $1,149,500.00 $8,330,200.00 Property herein described is assessed together with an undivided interest in Tracts B, C & D. 3. Notice of tap or connection charges which have been or will be due in connection with development or re -development of the land as disclosed by recorded instrument. Inquiries regarding the specific amount of the charges should be made to the city/county/agency. CITY/COUNTY/AGENCY: FEDERAL WAY WATER AND SEWER DISTRICT RECORDED: MAY 12, 1989 RECORDING NO.: 8905120210 Commitment for Title Insurance Page 3 of 10 SCHEDULE B (continued) 4. RELINQUISHMENT OF ALL EASEMENTS existing, future or potential, for access, light, view and air, and all rights of ingress, egress and regress to, from and between the land and the highway or highways to be constructed on land conveyed by deed. TO: STATE OF WASHINGTON DATED: --- RECORDED: OCTOBER 24, 1956 RECORDING NOS.: 4742325 AND 4742327 S. RELINQUISHMENT OF ALL EASEMENTS existing, future or potential, for access, light, view and air, and all rights of ingress, egress and regress to, from and between the land and the highway or highways to be constructed on land conveyed by deed. TO: STATE OF WASHINGTON DATED: ---- RECORDED: DECEMBER 29, 1970 RECORDING NOS.: 6727551 AND 6727553 6. RELINQUISHMENT OF ALL EXISTING, FUTURE OR POTENTIAL EASEMENTS for access, light, view and air, and all rights of ingress, egress and regress to, from and between the land and the highway or highways constructed on lands condemned by proceedings under King County Superior Court. BY: STATE OF WASHINGTON CAUSE NO.: 726977 7. ALL COVENANTS, CONDITIONS, RESTRICTIONS, RESERVATIONS, EASEMENTS OR OTHER SERVITUDES, IF ANY, DISCLOSED BY THE RECORDED PLAT OF EAST CAMPUS CORPORATE PARK PARCEL 3 BINDING SITE PLAN. THIS POLICY DOES NOT INSURE THAT THE LAND DESCRIBED IN SCHEDULE A IS BENEFITTED BY EASEMENTS, COVENANTS OR OTHER APPURTENANCES SHOWN ON THE PLAT OR SURVEY TO BENEFIT OR BURDEN REAL PROPERTY OUTSIDE THE BOUNDARIES OF SAID LAND. 8. License to Enter Property imposed by instrument recorded on October 28, 1998, under Recording No. 9810282068. 9. ALL COVENANTS, CONDITIONS, RESTRICTIONS, RESERVATIONS, EASEMENTS OR OTHER SERVITUDES, IF ANY, DISCLOSED BY BOUNDARY LINE ADJUSTMENT RECORDED UNDER RECORDING NO. 9810289003. THIS POLICY DOES NOT INSURE THAT THE LAND DESCRIBED IN SCHEDULE A IS BENEFITTED BY EASEMENTS, COVENANTS OR OTHER APPURTENANCES SHOWN ON THE PLAT OR SURVEY TO BENEFIT OR BURDEN REAL PROPERTY OUTSIDE THE BOUNDARIES OF SAID LAND. Commitment for Title Insurance Page 4 of 10 10 11. 12. 13. SCHEDULE B (continued) AND AMENDMENTS THERETO: RECORDED: JULY 1, 1999 RECORDING NOS.: 19990701001442 AND 19990701001443 EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: LAKEHAVEN UTILITY DISTRICT PURPOSE: SEWER FACILITIES AREA AFFECTED: A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT RECORDED: MARCH 1, 2000 RECORDING NO.: 20000301001566 EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: LAKEHAVEN UTILITY DISTRICT PURPOSE: WATER FACILITIES AREA AFFECTED: A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT RECORDED: MARCH 1, 2000 RECORDING NO.: 20000301001567 EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: PUGET SOUND ENERGY, INC., A WASHINGTON CORPORATION PURPOSE: UTILITY SYSTEMS AREA AFFECTED: A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT RECORDED: MARCH 2, 2000 RECORDING NO.: 20000302000618 EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: CITY OF FEDERAL WAY PURPOSE: FLOW OF SURFACE WATER AND/OR STORM WATERS AREA AFFECTED: PORTION AS DESCRIBED IN SAID INSTRUMENT RECORDED: MARCH 20, 2000 RECORDING NO.: 20000320001106 Said easement contains a covenant to bear equal share of cost of construction, maintenance or repair of same. Commitment for Title Insurance Page 5 of 10 SCHEDULE B (continued) 14. EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: CITY OF FEDERAL WAY PURPOSE: INGRESS AND EGRESS TO INSPECT AND MONITOR STORMWATER FACILITIES AREA AFFECTED: SAID PREMISES AND OTHER PROPERTY RECORDED: MARCH 20, 2000 RECORDING NO.: 20000320001106 15. License to Enter Property imposed by instrument recorded on April 20, 2000, under Recording No. 20000420000974. 16. EASEMENT AND THE TERMS AND CONDITIONS THEREOF: PURPOSE: INGRESS AND EGRESS AREA AFFECTED: A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT RECORDING NO. 20021119003369 Said easement contains a covenant to bear equal share of cost of construction, maintenance or repair of same. 17. EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: LAKEHAVEN UTILITY DISTRICT, A MUNICIPAL CORPORATION PURPOSE: SEWER FACILITIES AREA AFFECTED: A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT RECORDED: DECEMBER 12, 2002 RECORDING NO.: 20021212002936 18. EASEMENT AND THE TERMS AND CONDITIONS THEREOF: GRANTEE: PURPOSE: AREA AFFECTED: RECORDED: RECORDING NO.: LAKEHAVEN UTILITY DISTRICT, A MUNICIPAL CORPORATION WATER FACILITIES A PORTION OF SAID PREMISES AND OTHER PROPERTY AS DESCRIBED IN SAID INSTRUMENT DECEMBER 12, 2002 20021212002937 Commitment for Title Insurance Page 6 of 10 SCHEDULE B (continued) 19. COVENANTS, CONDITIONS AND RESTRICTIONS IMPOSED BY INSTRUMENT RECORDED ON MARCH 17, 2000, UNDER RECORDING NO. 20000317001901, INCLUDING, BUT NOT LIMITED TO, LIABILITY FOR ASSESSMENTS LEVIED BY THE COMMUNITY ASSOCIATION. THIS POLICY DOES NOT INSURE THAT THE LAND DESCRIBED IN SCHEDULE A IS BENEFITTED BY EASEMENTS, COVENANTS OR OTHER APPURTENANCES SET FORTH IN SAID INSTRUMENT TO BENEFIT OR BURDEN REAL PROPERTY OUTSIDE THE BOUNDARIES OF SAID LAND. 20 21 22 23. ORDINANCE AND THE TERMS AND CONDITIONS THEREOF: RECORDED: RECORDING NO.: OCTOBER 26, 1994 9410260933 AGREEMENT AND THE TERMS AND CONDITIONS THEREOF: RECORDED: RECORDING NO.: REGARDING: FEBRUARY 19, 1999 9902191372 SEWER AND WATER SERVICE AGREEMENT AND THE TERMS AND CONDITIONS THEREOF: RECORDED: RECORDING NO.: REGARDING: DECEMBER 22, 1999 19991222001594 SEWER AND WATER SERVICE DEED OF TRUST, SECURITY AGREEMENT AND FIXTURE FILING WITH ASSIGNMENT OF RENTS AND THE TERMS AND CONDITIONS THEREOF: GRANTOR: SC EAST CAMPUS, INC., A DELAWARE CORPORATION TRUSTEE: CHICAGO TITLE INSURANCE COMPANY BENEFICIARY: JACKSON NATIONAL LIFE INSURANCE COMPANY, A MICHIGAN CORPORATION ORIGINAL AMOUNT: $9,000,000.00 DATED: AUGUST 7, 2003 RECORDED: AUGUST 12, 2003 RECORDING NO.: 20030812001126 Investigation should be made to determine the present balance owed by contacting the appropriate lender/agency/individual. Commitment for Title Insurance Page 7 of 10 24 25. 26 SCHEDULE B (continued) SECOND DEED OF TRUST, SECURITY AGREEMENT AND FIXTURE FILING WITH ASSIGNMENT OF RENTS AND THE TERMS AND CONDITIONS THEREOF: GRANTOR: SC EAST CAMPUS, INC. TRUSTEE: CHICAGO TITLE INSURANCE COMPANY BENEFICIARY: JACKSON NATIONAL LIFE INSURANCE COMPANY, A MICHIGAN CORPORATION ORIGINAL AMOUNT: $9,000,000.00 DATED: AUGUST 7, 2003 RECORDED: AUGUST 12, 2003 RECORDING NO.: 20030812001127 Investigation should be made to determine the present balance owed by contacting the appropriate lender/agency/individual. SUBORDINATION AGREEMENT AND THE TERMS AND CONDITIONS THEREOF: RECORDED: RECORDING NO.: AUGUST 12, 2003 20030812001131 ASSIGNMENT OF RENTS AND THE TERMS AND CONDITIONS THEREOF: ASSIGNOR: SC EAST CAMPUS, INC., A DELAWARE CORPORATION ASSIGNEE: JACKSON NATIONAL LIFE INSURANCE COMPANY, A MICHIGAN CORPORATION DATED: AUGUST 7, 2003 RECORDED: AUGUST 12, 2003 RECORDING NO.: 20030812001128 ASSIGNMENT OF RENTS AND THE TERMS AND CONDITIONS THEREOF: ASSIGNOR: ASSIGNEE: DATED: RECORDED: RECORDING NO.: SC CAMPUS EAST, A DELAWARE CORPORATION JACKSON NATIONAL LIFE INSURANCE COMPANY, A MICHIGAN CORPORATION AUGUST 7, 2003 AUGUST 12, 2003 20030812001129 Commitment for Title Insurance Page 8 of 10 SCHEDULE B (continued) 27. FINANCING STATEMENT AND THE TERMS AND CONDITIONS THEREOF: SECURED PARTY: JACKSON NATIONAL LIFE INSURANCE COMPANY, A MICHIGAN CORPORATION DEBTOR: SC EAST CAMPUS, INC. COVERS: PERSONAL PROPERTY AND FIXTURES LOCATED UPON SAID PREMISES RECORDED: AUGUST 12, 2003 RECORDING NO.: 20030812001130 28. UNRECORDED LEASE: LESSOR: WEYERHAEUSER FINANCIAL SERVICES, INC. LESSEE: WEYERHAEUSER COMPANY DATE: NOVEMBER 1, 2002 29. Unrecorded leaseholds, if any; rights of vendors and holders of security interests on personal property installed upon the land; and rights of tenants to remove trade fixtures at the expiration of the term. 30. Matters affecting security interests in personal property which may be disclosed by a search of the Uniform Commercial Code (UCC) records at the Washington State Department of Licensing in Olympia. Note 1: Title will be vested in parties yet to be disclosed. When title is vested, their title will be subject to matters of record against their names. Note 2: A proper lease must be executed and recorded before the policy can be issued. We also call your attention to the necessity of examining the terms of the lease for provisions which might require the consent of the lessor to any transfer of the leasehold estate. Note 3: Evidence and authority of the officers of SC East Campus, Inc., a Delaware corporation, to execute the forthcoming instrument should be submitted. Note 4: There may be Uniform Commercial Code (UCC) Security interests filed with the Department of Licensing in Olympia, affecting personal property, crops or agricultural facilities which are not covered by the policy to issue. Commitment for Title Insurance Page 9 of 10 SCHEDULE B (continued) Note 5: The Company requires the proposed insured to verify that the land covered by this commitment is the land intended to be conveyed in this transaction. The description of the land may be incorrect, if the application for title insurance contained incomplete or inaccurate information. Notify the Company well before closing if changes are necessary. Closing instructions must indicate that the legal description has been reviewed and approved by all parties. Note 6: The following may be used as an abbreviated legal description on the documents to be recorded, per amended RCW 65.04. SAID ABBREVIATED LEGAL DESCRIPTION IS NOT A SUBSTITUTE FOR A COMPLETE LEGAL DESCRIPTION WITHIN THE BODY OF THE DOCUMENT. LOT 2 EAST CAMPUS CORP PARK PARCEL 3 Note 7: WHEN SENDING DOCUMENTS FOR RECORDING, PLEASE SEND VIA TDS (TITLE DELIVERY SERVICE) IN THE YELLOW RECORDING ENVELOPES WHENEVER POSSIBLE. IF THEY MUST RECORD THE SAME DAY, PLEASE CONTACT THE TITLE UNIT FOR SPECIAL DELIVERY REQUIREMENTS. IF THEY MAY BE RELEASED WITHIN 48 HOURS, THEY SHOULD BE SENT TO THE FOLLOWING ADDRESS: Transnation Title Insurance Company 1200 Sixth Avenue, Suite 100 Seattle, WA 98101 ATTN: Recording Dept. (END OF EXCEPTIONS) Investigation should be made to determine if there are any sewer treatment capacity charges or if there are any service, installation, maintenance, or construction charges for sewer, water or electricity. In the event this transaction fails to close, a cancellation fee will be charged for services rendered in accordance with our rate schedule. Unless otherwise requested or specified herein, the forms of policy to be issued in connection with this Commitment will be the ALTA 1998 Homeowner's Policy, the ALTA 1992 Lender's Policy, or, in the case of standard lender's coverage, the CLTA Standard Coverage Policy — 1990. The Policy committed for or requested may be examined by inquiry at the office that issued the Commitment. A specimen copy of the Policy form(s) referred to in this Commitment will be furnished promptly upon request. ]LB/rr enc. Sketch Vesting Deed Recorded Encumbrances Commitment for Title Insurance Page 10 of 10 THIS SKETCH IS PROVIDED, WITHOUT CHARGE, FOR YOUR INFORMATION. IT IS NOT INTENDED TO SHOW ALL MATTERS RELATED TO THE PROPERTY INCLUDING, BUT NOT LIMITED TO, AREA, DIMENSIONS, EASEMENTS, ENCROACHMENTS OR LOCATIONS OF BOUNDARIES. IT IS NOT A PART OF, NOR DOES IT MODIFY, THE COMMITMENT OR POLICY TO WHICH IT IS ATTACHED. THE COMPANY ASSUMES NO LIABILITY FOR ANY MATTER RELATED TO THIS SKETCH. REFERENCE SHOULD BE MADE TO AN ACCURATE SURVEY FOR FURTHER INFORMATION. SECTION: 22 TOWNSHIP: 21 N RANGE: 04E R-50 r as. f9 ne7ae-�r �� rbr_ _ 50.d1 40 fA30- t' w .flT V� -+],3fl N64-df-ldw rp-55-3 5.20 7S7• Y2"a f5.07 k•�3 N66-d6-0 tM �4 --` -1 107.90 o y w - Tr C a�2• AW w d - . p y�1 55 �7Adic 1 Lot 2 Imw p -e F f6d. I9 �4 Ali �`'� I 1 2021160Bd r tilpry_�rt a OD40 19.87 J� lo71i ► / �/ ! , 32 Lot t 124 a y fJs % 3� d.a6 •0 19 fi1Or I -rj � 33 000 p Tr A er ► V .00e SG• St�sa wat to ' 1.09 aC ` a d0a� II / 15. 26 / i / 5�. { yw �A �- -- - - - - 1 15aia 40 I �1 u L / 1 Ir- I-P� - - - - - - - - - - - -� - - - - - -7-- - . _--------------_.._..._�I-.- - 10/29/03 15:59 FAX 415 676 2293- SSR REALTY ADV 1EG�tED Q001 OCT 3 " 2003 CZ i Y 0, FEI)ERr1L W CITY OF BUILDING 1) p7 E Federal Way 0 MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33530 First Way South CULIVE� POBox9718 C Federal Way WA 98063-9718 253-661-0000; Fax 253-661-4129 ww w- cuffed era l �vaY.COm OCT 1�1 n 2003 r= CDERAL t% APPLICATION NO(S) Date 10/24/03 Project Name AT&T Wireless_Weverkiaeu Ai5te SS81 Property Address/Location 33930 Weyerhaeuser Way Parcel Number(s) 2154660010 Project Description Install minor wireless telecommunications facility oin the roof of an existing commercial office building and attach antennas to office building penthouse. PUFARF. PRTNT Type of Permit Required Annexation _ Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference X Process I (Director=s Approval) Process IT (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information OP 2 Zoning Designation Office Park Comprehensive Plan Designation $8`2M Value of Existing Improvement; $30.000 Value of Proposed Improvements Uniform Building Code (UBC): B. Office Occupancy Type it fully snriOlcrad in lieu of l TIaur Construction Type Applicant Name: Norris Bacho Address: 1426 Harvard Avenue # 11 City/State: Seattle, WA Zip: 98122 Phone: (206) 2274443 Fax- (206) 283-2680 Email: norris gwt.n t Signature: Agent (if different than Applicant) Name: Address: City/State: Zip: Phone: Fax: Email: Signature: Owner Name: SC East Campus Inc Address: One California Street Suite 1400 City/State: San Francisco, CA Zip: 94111 Phone: (415) 678-2105 Fax: (415) 835-0972 Email: Hiroe.` a euchi@ Real€ .com Sigpatur Bulletin #003 - March 3, 2003 Page 1 of 1 k:\I3andouts - RevisedWaster Land Use Application cn c . 'raw • r �. i T 4- j Ln ro LU —C 4-7- 0 E 0 4� 0 J f F k }i f . L 1 Pi •+ram It y • • ' ri'}rram' } • INjo - All Aw 4-1 Y / j,�/ ,yI� �♦ cn •44 , ' • ; i a �ti ! . Y�AAAFFF a . PAP ^ 4, - & V M L A ZVz • S � � i, �rM� - 7 • -mil .� + �` r { �. � i� 1 j I! ra+l ! ■- � . '-1 ' +Y �iM Fes' �� -. ��1��� �� `� � 0 po 1 k�Y• 0 W 0) 0 0 a� m r. 1.. tek y }1 . Ln r 0 4-1 f , 4-i Ln LU cn no t 0 Lam.. D Z Q; 1 � r N 1 r Q , F ,,j v, ,'e� G-U7 r cfA C aC 3 aQ 0 • � ,1 � ICI ��+� 1� L a, "Ito, �: = -w L+� � _ r. - � ,, .: w � �. :- rti • -� -`s� _ ...-», �_� Lam-•- � � � 1 ��tr� - - � _ � � ,. ti i .� � - _ � � { _- .� � _ - JJ •� .L a. W tL %4- L 0 LL, % < til > LU Lu LL ul LL-j > ca Z5 I A/C ADJ. AFT AMSL APPROX. ASTM AWG BLDG B BILK. AIR CONDITIONING ADJUSTABLE ABOVE FINISH FLOOR ABOVE MEAN SEA LEVEL APPROXIMATELY AMERICAN SOCIETY FOR TESTING AND MATERIALS AMERIPAN WIRE GAME BLOCK BUILDING BUILDING STANDARD GA GALV. CC GB GRIND GWB HDWD. HORIZ. HR HT. HVAC GAUGE GLUE LAMINATED BEAM GROUND GYPSUM WALL BOARD HARDWOOD HORIZONTAL. HOUR HDGIT HEATING, VENTING AND AIR CONDITIONING PL PLYING. PR PROD PROP FT REO'D RM R.O. S SCHED SHT PROPERTY LINE PL1W000 POUR PROJECT PROPERTY PRESSURE TREATED REQUIRED ROOM ROUGH OPENING SOUTH SCHEDULE SHEET A & E ! R ANGLE AND AT CENTER LINE NUMBER PLATE CLC CEILING SPEim. SIMILAR CLR GONG. CLEAR CONCRETE I.D.IN. INSIDE DIA SPEC. SO SQUARE ATION SQUARE Q REVISION CONSf. CONSTRUCTION INCH SS STAINLESS STEEL CONT. CO. CONTINUOUS COMPANY INFO INFO INFORMATION INSULATION SIL STRUC STEEL STRUCTURAL Og _ KEY NOTE INT. INTERIOR SUSP. SUSPENDED DBL DOUBLE S.V. SHEET VINYL DID. A DING. DWMETFR DIAGONAL LB(S) POUND(S) THRU THROUGH A_1 e DETAIL REFERENCE DIM. DIMENSION TNND TINNED ON DOWN MAX MAXIMUM T.O.C. TOP OF CONCRETE DR, DER DETAIL MECH MECHANICAL T.O.M. TOP OF MASONRY ELEVATION REFERENCE DWG. DRAVIING MR MEFAL TS TUBE STEEL 8 ® MFR. MANUFACTURER TYP TYPICAL E EAST MGR MANAGER UBC UNIFORM BUILDING EA EACH MIN MINIMUM CODE EI. EEV ELEVATION MISC MISCELLANEOUS UL UNDERWRITERS LAB TOO ROOM NUMBER ELECT. EIECTRI UUO UNLESS NOTED ED EQUIP. EQUAL EQUIPMENT N NORTH VERTE.W. OMFIiA15E VERTICAL EACH WAY FA NIC NOT APPLICABLE. NOT IN CONTRACT IN t SECTION REFERENCE DL EXT. DDSTING EXTERIOR NTS NOT TO SCALE VR TINEnELD NFDVIF W WEST FIN. FINISH O.C. ON CENTER W/ WITH FLUOR. FLUORFSCENf 00 OUTSIDE DIAMETER WOW WINDOW ELEVATION MARKER FUR FT. FLOOR FM OPG. am OPENING OPPOSITE W/0 W.P. WITHOUT WORKING POINT ABBREVIATIONS AND SYMBOLS DRIVING DIRECTIONS FROM SEA-TAC AIRPORT, HEAD SOUTH ON 1-5. TAKE THE HWY 18 EAST EXIT. TAKE THE FIRST EXIT (WEYERHAEUSER WAY Sj- AT THE ENO OF THE OFFRAMP, MAKE A LEFT IMTO WEYFRTNSEUSER WAY S. STAY IN THE RIGHT LANE AND TURN RIGHT INTO THE BUILDING COMPLEX. BUILDING •Ei IS THE SECOND ON RIGHT, IN THE SOUTHEAST CORNER. VICINITY MAP AND DRIVING DIRECTIONS SCALE: NTS LEGAL DESCRIPTION: LOT 2 EASE CAMPUS CORP PRK PARCEL 3-BSP TGW LAND INT IN B.C&D LEGAL DESCRIPTION ARCH PS ARCHITECTS, INC. SrrE ACQUISITION REALCOM ASSOCIATES, LLC - 303 BATTERY STREET 208 WESRAKE AVENUE NORM SEAT LE. WA 98121 SEATTLE, WA 98109 TEN• 206.443.9790 TEL• 206.490.3019 FAX: 206.443.9875 FAX: 206-490.3839 CONTACT: PETER BOCEK CONTACT: ROD HANSON STRUCTURAL ENGINEER PB ARCHITECTS, INC ZONI REALCOM ASSOCIATES, LLC 303 BATTERY STREET 208 WESRA(E AVENUE NORM SEATFLE. WA 9B121 SEATRE• WA 981D9 TEL 205.443.9790 TEL- 206.227.4443 FAX: 206.443.9875 FAX: 206.490.3839 CONTACT: PETER BOLOTSKJ CONTACT: NORRIS BACHO DESIGN TEAM SITE ALGAE, OWN� WEYERWIfLISER SC EASE CAMPUS, INC. SITE NUMBER, ONE CALIFORNIA ST. Su, -It 1400 SAN FRANCISCO, CA 9A111 5581 TEL: 415.6782105 CRC ADDRESS FAX: 415.835.0972 33930 WEYERHAEUSER WAY CONTACT: HIROE TAKEUCHI FEDERAL WAY, WA 98001 AT&T WIRELESS SERVICES INC. d.b.0. AT&T WIRELESS SERVICES 145GO HE 87M STREET REDMONE. WA 98052 TEL 425.702.3697 AT&T WIRELESS SERVICES PROPOSES TO CONSTRUCT, OPERATE AND MAINTAIN AN UNOCCUPIED COMMUNICATIONS FACILITY. THE FACILITY WILL CONSIST OF RADIO EQUIPMENT CABINETS• (APPRDJL 271 SD. FT) NSTALLEO ON THE ROOF OF THE EXISTE4G BULOdH: LOCATED INSIDE THE PAOPOSFA MECHANICAL SCREEN EOERmN, WRH ANTENNAS FOR SOsWUIECARQNS ATTACFffD TO THE (XrONG AND EXTDMDEQ MECHANCAL SCREEN. THE EQUIPMENT CABINETS CONTAIN IELCO. RADIO AND POWER EQUIPMENT. PARCITIL NUMBER JURISDICTION: ZONING: 215466 0020 CITY OF FEDERAL WAY OFFICE PARK 2 (OP2) TELEPHONE UnL1IY: L ECTRICAI Larry, FIR 0 P cruRNr• OWEST PSE FEDERAL WAY FIRE DEFT. BUILDING CODE: UBC 1997 OCCUPANCY: B - OFFICE PROPERTY ACREAGE 3.77 EXCAVATION: NONE BUILDING AREA: 71,704 0 ST VALUE: $30.000 CONSTRUCTION TYPE: II - FULLY SPRINKLED IN LIEU OF 1-HOUR AOA CQIMi+LLANCC Fiu{,'R c WYwE9 MXI HM TOR •tW+� WBITATRN PROJECT SUMMARY 1 WIRELESS SERVICES ens vtce- mw SITE wee WEYERHAEUSER vP-z ( SITE NUMBER: SS81 Ar.-; -ovcd By: Co. mentm i. CITY Dr 1 FEDERAL WAY IRE NO. T-1 I TITLE SHEET rA-4 OVERALL SITE PLAN ROOF PLAN. ENLARGED ROOF PLAN ELEVATIONS 3RO FLOOR PLAN, BUILDING SECTION, DETAILS ENLARGED PLAN, CONSTRUCTION NOTES, CONSTRUCTION DETAILS S-1 STRUCTURAL PLAN. STRUCTURAL DETAILS, STRUCTURAL NINES S-2 STRUCTURAL DETAILS E-1 I ELECTRICAL NOTES & DETAILS, GROUNDING DAGRAM & Dams SHEET INDEX THE FOEI,DW,NG PARTIES HERE• APPROVE AHD ACCM )ALES£ OOC, WE7ITS AFA AVMDRtIE THE COwmOZIOR TO PRO= MTN IRE DDHSFRLICTm DESOPoBEID HFFZM. ALL OGHS'FROCTKNI D=MIE ITS ARE UagCT TO FM" W THE UfA BUILDING DEPARTMENT AM ART DAM OR LIOD ICAT015 TFIEY MAY p[POSE LANDLORD/OWNER DATE AT&T SIGNATURES DATE PM CM SA ZN AT&T RF AT&T SA AT&T PM AT&T SDM (optional) SDM'S SIGNATURE CAN SUPERCED ALL OTHER SIGNATURES PRESENT_ APPROVALS -----. AT&T � WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. rc 0 PRODUCED SOULLY FOR USE Bf THE QETILFN A: RS lATTTIJ4'M ROV40L NM OR USE OF IFAS ORVMENG AEAIOR THE IIFDAMATWN CONTAM IN IT IS F' MADE I WITHOUT THE WRITTEN PERMISSION OF THE OWNER TO E 0 (2DO) ua 75 I SOME A ., _ 6FTE ME WEYERHAEUSER STIE wim SS81 PBA JOB NULNER N HORSE 231176 DPJM BY: RKL CHIECIO;L Bh EJS SITE AWF ESS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 PLOT SPAR: S. 337th ST, I{{ \ I 7 S. 337th ST. . . . . - . . • ' ��•.�' . w r � --"------•` 7, �,� ! 20.0' ZONING SETBACK '�'.,. - •� r•l•S• rl�.- . 5 fl5'04_S4LE 679.Sfl� _� r f .. • .' : �••� . ` •'�•r` ..fir•.-, •,•• - I I �``�— ' _, ,�� •�• 1r� \ � n� �-.�" _�.C'. ZflHINGSETBACIL.... ...r•�� •�. �• .F���—�`— �� �f.-�-�•• -• -••• i 1 ♦ �% lo I,y - -rt;•: :':%`•jam" / :' r - I 1 l ^` s i 1 1 ! .S�rd I . � • . •. 7g2R'39� 1 `t % � ExTr J143 SOUTH nvH ST s wLn 3 ix Lo PRWECT LOCITK.Rooftop b ----- 1 [ B A NORTH cAlfw Ir i 1 � .'x ji SITE PLAN NOTES: CAMPUS 6 'PROJECT 1. PARKING, NO PROPOSED CHANGES SOUTH y6A LOCATION 2. PROPOSED ROOFTOP EQUIPMENT AREk IA1f APPROXIMATELY 271 SQUARE FEET - J r DEFRAL WAY ! TE � ING DEPT EXIT J1i2EI wato E PLAN IS A DIAGRAMMATIC REPRESENTATION ONLY, DO NOT SCALE; 0142A 11.SRVISION VERIFY ALL DIMENSIONS 2- VERIFY ALL PROPERTY LINE INFORMATION WITH EXISTING SURVEY DATA OVERALL SITE PLAN SCALE Y = loo-or 16 VICINITY MAP SCALE: NTS 1 20 AT&T WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. If IS PRODUCED SOLELY FGR USE BY THE 000 NO ITS AFF LXM RFPRODU01OR OR USE GF TM Ir:K N30/0R 11ri� THE ORWATIOX CONTAINED 44 R R fOM DDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. . A k—N - M -1 pne) aa•noo RELFASE M7E 21OCT03 CO REVIEW 22OCTO3 CO HNAL WEYERHAEUSER 8881 PBA JOB NUI�R N HOl)g 231178 CRON W. RKL CHECKED BY: EJS SIZE ADDRESS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 SHEET TIRE OVERALL SITE PLAN A-0 PLOT SCALE: 1:1 go IX. WAXING L •- 1 WALKING PAO. TIP. :r ENLARGED ROOF PLAN IX. WALKING --------- *I--w.-- Ta>,------- i DESCRIPTION SEE REFERENCE !PROPOSED FLUSH MOUNTED AT&T PANEL ANTENNA !PANTED TO MATCH MECHANICAL SCREEN 16 S-1 1b1 !PROPOSED FLUSH MOUNTED AT&T PANEL ANTENNA !PAINTED TO MATCH EX. MECHANICAL SCREEN 16 5-1 AI (PROPOSED WALKING PAD, TO MATCH IX F63 (PROPOSED AT&T EQUIPMENT CABINETS 4 A64 (PROPOSED MECHANICAL SCREEN EIOENSION 3 4 -a -a !PROPOSED AT&T COAXAL CABLE, MOUNTED ON THE (MECHANICAL SCREEN !8 4 M !PROPOSED AT&T ELECTRICAL PANELS AND DISCONNECTS 1 J !PROPOSED POWER AND TELEPHONE CONDUITS, DOWN TO 3RD FLOOR LEVEL 10 3 :PROPOSED AT&T CABLE ROUTE O PROPOSED CABLE BRIDGE 4 KEY NOTE LEGEND ANM*IA LEGEND ALPHA SECTOR BETA SECTOR GAMMA SECTOR AZIMUTH 55' 23D 330' ANTENNA MODEL ALLGON 7920.00 ALLGON 7920.00 ALLGON 7920.DO ALLGON 7721.00 ALLGON 7721.00 ALLGON 7721.00 ANTENNA COUNT (2)7920.00/(2)7721.00 (2)7920.00/(2)7721.00 (2)7920.00/(2)7721.00 ANTENNA MOUNT HEIGHT 52'-(r 53'-10' S3'-10' COAX TYPE/SIZE 7/8`0 7/8Y 7/8': COAX LENGTH 1B't 100't 193't DOWNRLr G. IT 0' Ae7 ELECTRICAL !� EQUIPMENT, TYP. f„�C(Wf CABLE FIVE U Lu 0 Z 2 SCALE_ yt _ 1'-If 112 ROOF PLAN ATQT WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 AL SCREEN, TYP. OF 2 4N, TYP. THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN ITIS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. 10 Rf Air ear r (soe) us -oats CESS HATCH PAD, TYP. T&T PROJECT AREA ANTENNAS, 3 SECTORS, TED TO IX. AND NEW SCREEN Wm-7 1 cic 417E 21 OCT03 CO REVIEW 22OCTO3 CD FINAL 1 I SITE N1YE _J 1 WEYERHAEUSER SITE mum SS81 PBA JOB MNBEIt N 110115E _ 231176 NM BY: RKL O ,1 p EI:ID;D B!:S EJ f °: E "tom` SIZE ADDRESS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 :i SHEET TITLE VL € T �r T=F_�'crr'-,L 1'",tyV' ROOF PLAN J i L � I J T ENLARGED ROOF PLAN G D ;� E_ 0 2SHEET NUIEER Or. I- A-1 SCALE %e = 1'-O' 20 PERT SCALE 1:1 NOTE: PROPOSED MECHANICAL SCREEN EXTENSION AND ALL PROPOSED ANTENNAS/MOUNTS TO MATCH COLOR OF EX. MECHANICAL SCREEN. l ESCRIPTION SEE REFERENCE AI# (PROPOSED FLUSH MOUNTED AT&T PANEL ANTENNA, 16 (PAINTED TO MATCH MECHANICAL SCREEN S-1 IPROPOSED FLUSH MOUNTED AT&T PANEL ANTENNA 1fi PAINTED TO MATCH EX. MECHANICAL SCREEN 5-1 AN7 (PROPOSED AT&T EQUIPMENT CABINETS 19 a Ai{ IPROPOSED MECHANICAL. SCREEN EXTENSION 3 4 -4 -4 KEY NOTE LEGEND D Q a i am i Mason ■� ■� HE ii ii C� SOUTH ELEVATION o i r r u SCALE: Yid' = 1'-D' ! 10 I WEST ELEVATION ° u SCALE- %d AS{ MECMA�WA SCREEN A17 PANEL ANTENNA TYP. EIVE W EQUIPMENT CABINETS A40 PANEL ANTENNA TYP. A$0 PANEL ANTENNA TYP. �y � A8T PANEL ANTENNA, TYP. km 1KT NNj SCREEN j 0 n? O'M1i 5 6 7 8 I MH1F1AwCAt IA C 0 MECHANICAL _ u 010r,RAID CIR. �-T I �R1V7 C7Tt — PARAPET-� — PAf84PET sz'-o• FLOOR 3R0 FLOOR J. iE 77, '.� � t E t -i. 1 _.. Tsr TLOQR 7ST FLOOR �Fee WYED BUILDvgc OCT 3 Z�Q? CITY OF FEDERAL WAY BULDING DEP T , NORTH ELEVATION 11 " SCALE: yis = 1'-V 12 EAST ELEVATION o �• r v a SCALE: '%e = t'-o 20 .-- AT&T ' � WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN R IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. RELEASE DATE 21 OCT03 CD REVIEW 22OCT03 CO FINAL RE�AS015 NO.1 DATE 4 sa Mw WEYERHAEUSER sss PISA JOB NIR®t N Fldhi 231176 DRM BY' RKL CHECKED BY: EJS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 SHEET TIRE ELEVATIONS SHEET NUMBER A-2 PLOT SCAL. E=5 } p4 cf ...rno�ry ( �ARDP�W ATkL I RaiRK'J�/Ip,FPNONE CWSET j IEEE ARFA ROOM PROPOSED POWENCOUDUB IN L J PONEA ANU PROPOSEO�IE COF7pUT CEIUK: SPACE, 9liPPOR[@ IEDEPIIOIi CON FROM IN CEILM7G ACE. SUPPORTED I� PER NEC RkjQNf�15 AT�T wa AREA) am I PEN NEC REW WEMENTS I I NOTE REFER TO DETAILS 13/A-3, 14/A-3 AND 1B/A-3 FOR INTERIOR WALL PENETRATION U FLOOR PLAN NOTE REFER TO DETAILS 13/A-3, 14/A-3 AND 18/A-3 FOR INTERIOR WALL PENETRATION BUILDING SECTION PROPOSED MECHANICAL SCREEN EXTENSION PROJECT N o r SCALE: I' - 20'-O' MINIMUM 2-1/Y THICK CONCRETE SLAB (OR CONCRETE SLAB OVER STEEL DECK). MAXIMUM DIAMETER OF SEALANT, MINIMUM 1' OPENING NOT TO EXCEED 5. THICKNESS MAXIMUM S DIAMETER CABLE BUNDLEMINERAL WOOL BATT, NOMINAL THE ANNULAR SPACE WDHIN THE FIRE 4PCF, PACKED TIGHTLY AND STOP SYSTEM SHALL RANGE RANGE FROM INSTALLED TO 1-1/Y DEPTH, POINT OF CONTACT TO 2' MAXIMUM, RECESSED TO ACCOMMODATE FILL MATERIAL ASTM E814 (UL1a79) CDM?iIANT. ASTM E119 COM=LLVe,_ (TIAC/TT_u PERATURE EXPOSURE, COTTON WASTE IGNITION) 2 HOUR CABLE FlRESTOP THROUGH FLOOR (CA) 3133) SCALE: NONE CABLE v a � ¢ 4 I Z--- CONCRETE OR CONCRETE BLOCK WALL MAXIMUM OPENING 2-1/2, SRECSEAL SERIES 100 SEALANT OR PUTTY. SEALANT INSTALLED TO 51T DEPTH WITH 1/4' CROWN, PUTTY INSTALLED TO 3/4' DEPTH. ITRESTOP FELLOWS, LOWIM CONCRETE OR CONCRETE BLOCK OIMTNS)CW OT PoLCOYIS ]NSTA1Im MAXIMUM OPENING SIZE TO PERPENOECULA4 TO THE DUNE OP TEIE 271-1/2' SO. IN. WITH MAXIMUM WALL PILLDWS TO BE COMPRE%ED TO DIMENSION OF 22-5/SI A MWINUQ OF 30% WHEN O+S mim. MULTIPLE ELECTRICAL CABLES. MAXIMUM CABLE BUNDLE NOT LARGER THAN 3-311r. %OmKAL 1' DIAMOND SHAPED WIRE LATH FABRICATED FROM 20 G4. (MIN.) GALVANIZED STEEL WIRE ATTACH LATH TO WALL USING TAPOON-TYPE FASTENERS WITH FENDER WASHERS AT O'EI OVERLAP LATH UNDER A SINGLE FASTENER OR USE TWO FASTENERS WHERE LATH IS CUT TO FILL CABLE TRAYS. (PUTTY -NOT SHOWN. USE PUTTY TO FILL ANY VOIDS AROUND CABLE OR GABLE TRAYS.) A50A E814 (UL1479) COMPLIANT. ASTM E E (UL1479) COMPLIANT. ASTM E119 COMPLIANT. (TME/TEMPERATURE EXPOSURE, COTTON WASTE IGNITION) ASTM E119 COMPLIANT. (PME/TE)APERATURE EXPOSRE, COTTON WASTE IGNITON). 2 HOUR CABLE FlRESTOP THROUGH WALL (WJ 3017) SCALE NONE 1 14 1 2 HOUR CABLE FlRESTOP THROUGH WALL (WJ 3023) SCALE: NONE NOTE: PROPOSED MECHANICAL SCREEN EXTENSION AND ALL PROPOSED ANTENNAS/MOUNTS TO MATCH COLOR OF IX MECHANICAL SCREEN. MECHANICAL SCfi2EFNN 55'-1U 10 3RD FLOOR JO'-0' 2ND FLOOR VW o s A. SCALE: 1' = 10'-0' t� AT&T WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY iNE OABER ANO ITS AFTiL51E5. REPR�L4i1pN OR USE OF iF0.5 M WNG AId W TIC INFORMATION COHTNNED IN IT IS TOOOEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER m-n-1 1 0 (M) 445 a 75 j WEYERHAEUSER sBE MAW SS81 PBA JOB NUIBEIt W 11016E 231176 DP""B EPP RKL CHMIKI:D BM EJS SIIE AOWRISS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 (RHM TITLE 3RD FLOOR PLAN BUILDING SECTION DETAILS SHEET mum A-3 PLDT my c. 1:1 NONNI.TIN NEW AND EXISTINGNOKIA CABINET COTAILS SCREEN I WALL j 1 I FRAMING I CABDREI PLATFORM SUPPORT, - - - - _ _ _ - - ANI]gI1E'O TO °LA$ - - - - SET MEMBER ON APPROVED ROOFING MASTIC (WATER TIGHT) JL CANT STRIP , DETERMINED BY SIZE AND NUMBER OF CABLES 1V,i2' UNISTRUT CHANNEL AT 3'-O'3 OC kDR ZONW1Y UM M6 COAX HANGER CABLES FURWSHED BY AT&T, INSTALLED BY CONiAACTOR; CONOIAMR TO COORDINATE INSTALLATION W/ PROJECT MGR. ANCHOR THRU BOLT OR CLAMP OF AS REQUIRED (TYP.) PLATFORM SEAL TO ROOF SCALE 1 A%! = 1'-0 1 CABLE RUN SCALE: 1'=,'-v 1 5 PAINT ALL EXPOSED SURFACES TO MATCH EX UNLESS NOTED OTHERWISE INSIDE DUT47E (SCREaI [sGfFErr +ram 72 GA G.I. PREPRIMED i/ COPING FLASHING, BLACK (MATCH EXISTING) 3 5/6 1BG4. Un I 1/Z PREPRIMED METAL DECK STUDS O 1E O.C. HORIZONTAL. PAINT BLACK (MATCH EXISTING) m Tnm- 4x4' SR TUBE PER STRUCTURAL, PAINT BLACK 0 (MATCH EXISTING) 24GI. G.I. DRIP FLASHING (MATCH EXISTING) 2yG,l Gd. CAP FLASHING/ PITCH POCKET —ILL w/ R10FWG MASTIC DETAIL APPROYEO EIY ROOF SUPPLIER y 24GL G.I. COUNTERFLSHING y >7 y COMPOSMiMON CANT STRIP EX ROOF SYSTEM AtW BRACE AND CONNECTION PER STRUCTURAL 22CA G, CAP FLASHING/ PITCH IAOCNET�II.L ROUTING MASTIC DETAIL APPR W BY ROOF SUPPLIER 24GA G.I. COUNTERFL/SiING COMPOSITION CANT SUP 'WSJ El. ROOF SYSTEM MECHANICAL SCREEN SECTION SCALE 1' = V-e 3 PITCH POCKET - PLATE SLUE 1• = r-cr 17 A& SKgfiR TF 22CA G!. CAP iLASHING/ PITCH 22 GA -PREPRINTED POCMET-FILL W/ RDCfw6 MASTX COPING FLASHING, BLACK �4 DETAIL APPROVED BY ROOF (MATCH EXISTING) SNIPPLTR PRE-FRNSHED METAL SIDING, 248A. G.I. COUNTERFLSHING BLACK (MATCH EXISTING) „ COMPOSITION CANT STRIP L' EX. ROOF SYSTEM Iv d. b CONPM104 BEAD OF WATER PROOF SEALANT AROUND OPENING PROPOSER} GALV SR CONDUIT, b r B 6 50 PIhN i[S PUYI CL SEE PLAN MECHANICAL SCREEN ELEVATION SCALE %C = I'-(' 4 PITCH POCKET - CONDUIT SCALE: 1' = V-O' KEY NOTE QA NOKIA ULTRASTIE (OUTDOOR BTS) WEIGHT: 770 LEIS HEIGHT: 76.4 QB NOKIA ULTRASITE (OUTDOOR BITS) WE3GHT: 770 LETS HEIGHT: 76.4' l� NOKIA ULXRLSITE (OUTDOOR TITS) - FUTURE WEIGHT: 770 LETS HEIGHT: 76.4 O MONO IBIS (iNDDOSjOVTOOCR MICROCELL) WEIGHT: 211 LBS HEIGHT: 27.6' QE PROPOSED ICE BRIDGE OF PROPOSED COAX CABLES © PROPOSED WBx15 L=9'-9' BEAM, TYP. OF 2 e 1 OH NEW CONCRETE SLAB TO BE CONTIGUOUS, INCLUDING PUNTH. ENLARGED EQUIPMENT PLAN (SEE STRUCTURAL) I (SEE G �1 r'�t G NEW 4 7HCL 'a CONCRETE + OH NEW RAISED AREA. Y TOTAL THICKNESS — — r----1 F I r- a 11 II 11 II t L{ II I! II �" II II � II II © III ii� + rti svL---, L : , I L---JL---Jill CAM STRIP AROUND—f RAISED AREA NIDY CGNrr+tlE EXTENDS TO QiA - s-� - c A• Y � ° f a IX. CONCRETE ARFAG • .. 4 d (4' THICK) • . A e 4 NOKIA CABINET CABLE BRIDGE CABLE BRIOM DUNT END OF BRIDGE TO UN6TRUf 6IfilT. MOUNT TO MTL SIM -..EACH END ,GALV. S L CABLE UROGC INSTALL PER MAIUFACTUREB'S REODWMRtlNTGN 11 L'ODL GABLE. IYP. Kv ME WALL GNLV POSE PTt'CIO POCKET FOR NIECDWO SEAL SCALE' W = 1•-T 4'-5 mv CANT STRIP ON ALL PLINTHS. TYP. 4 N a w 2 e o z� cc a SCALE: W = 1'-0' 18 T.O. MECHANICAL SCREEN EXTENSIDN 9' LLCM muRE OUEDDOR LIGHT' SATICH 3 5/Ef MR STUDS O 1 K O.C. OUTDOOR I QURiT 200A ELEC. (3) UNSTRUT O PANEL SERVICE 1'-.T O.C.. MOUNTED D BOARD SWITCH!TO A�iNTICA MTL •HOFFMAM D STUDS TELEPHONE I Box NOTE - MOUNT TELEPHONE BOX, ELECTRICAL PANELS AND x EQUIPMENT TO UNISTRUT h PER NEC STANDARDS. 2•• to. ROOF GY.Y. SR CONDUIT, TIP. CONDUIT TO EQUIPMENT CABINETS, TYP. PRCN POCKET. 1W, UTILITY BACKBOARD ELEVATION SCALE: N.TS. 119 1. PANEL ANTENNAS CAN BE ROTATED 3O IN EITHER DIRECTION OF TOPHAT OR PLATFORM FACE DIRECTION TO ACHIEVE DESIRED AZIMUTH. CONSULT WITH CONSTRUCTION MANAGER IF A GREATER DEGREE OF ROTATION IS NECESSARY FOR ANY SECTOR. 2. PANEL ANTENNA AZIMUTHS ARE MEASURED FROM TRUE NORTH. 3. PANEL ANTENNAS SWNl BE SEPARATED 3'-Hr MINIMUM. 4. MHA'S TO PANEL ANTENNAS SNA L BE INSTALLED AT PORTS NO. I AND NO 2 ON PROPOSED ANTENNA, CONFIGURATION (AT ANTENNAS ON BOTH ENDS OF EACH SECTOR PER TOPHAT OR PLATFORM), UNLESS NOTED OTHERWISE UP TO ONE MHA PER ANTENNA 5. ALL ANTENNAS SHALL BE MOUNTED TO MANUFACTURER'S SPECIFICATIONS. 6. EXISTING ANTENNA MASTS ANO/OR PIPE MOUNTS AT EXISTING STRUCTURE TDPHIATS OR PLATFORMS SHALL L BE UEAHTEO AS APPROVED EQUAL BEFORE ANTENNA NSTALLATON. RELOCATE ' MASTS AND/OR PIPE MOUNTS AS NECESSARY, SEE NOTE 3. 7. CONTRACTOR TO SUBMIT ANTENNA VERIFICATION SHEET UPON COMPLETION OF INSTALLATION. SHEET M BE LEFT ON SITE B. SWEEPS TO BE PERFORMED: �..f 1. LOAD 2. SHORT 3. SYSTEM 9, PEAVORMED SWEEP TEST RESULTS (WHEN SHALL BE -REPRODUCED. AND DELIVERED AS FOLLOWS: L I HARD COPY LOFT AT SITE .I 1 SOFT COPY LEFT AT SITE 1 HARD COPY SUBMITTED WITH TURNOVER PIACNAGE ANTENNA NOTES - - `I "L Ta TP9Ni 20 - AT&T WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. _ ` PB. ARCH1TSCf$ } I ONN:T3 a4a-� ' (zae) 440-R99R tO EM DATE 21 OCT03 CD REVIEW 22OCT03 CD FINAL REY5pI6 NO.1 DAIS 1 SITE INNE WEYERHAEUSER SITE NUMBER SS81 PeA ,Joe NUBER w MRIN35E 231176 DRWN �: RKL CHECKED BY: EIS SIZE ADDRESS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 SHEET TIRE ENLARGED PLAN CONSTRUCTION NOTES CONSTRUCTION DETAILS SHEET NUBER A-4 PLOT SCALE: 1:1 S T al ZS L Df. OWSJ 22K4JLWL ---------------------- - _------------IX.- O--2-2K-4 ------ -� i I 7 i -- D(_OWSJ 22K4 ---- -� -- ---- ----� 4' SLAB W/- 1 14O1KO.G 8 EA WAY b m - �� EK COLUMN 1 TYP. i 6 Ii 17 i Ex. W24X55 — -- i— -------9' 6--, f i— _ ELL oWSJ z61(s —1— — — — — • { I 1 i EQUIPMENT PA0. 7 (TOTAL) RACK 3 CONC. SLABN5. BR2 i 1 TYP. OF 2 I IX. OWSJ 16K3 ------ _ _ - EX. OWSJ 26K5 - E3�W1�Rfs-- i I 17 �IX. OW5-- -------_ I I--- EX- W12X14 .-.�-------I-------- I I -- IX_OWSJ 26K5 ,------ -� ENLARGED STRUCTURAL PLAN r 1 • SCALE: %+• = I'-tl 16 I MECHANICAL SCREEN SECTION - BR1 19-Y 4' THICK CONCRETE SLAB NEW 4 CONCRETE ON IX. MTL =9 WELDED STUDS, (2) 3/CO. L=4 1/Y 0 If O.C. 15 S- EQUIPMENT PAD, 7- (TOTAL) CONIC. SLAB 1S-ftl TIGGC CONCRETE Sub WELDED STUDS LOCATION It 1/4X4, A325N (4) 3I 4 1/Y STUDS MJ (2 11Y STIgS) Ll CONCRETE SLAB SECTION OF R L SCALE: 1' = 1'-T 3,-tl OF R NUIL 1/4 TS BETWEEN POSTS. TYP. PITCH POCKET NOT SHOWN FOR CWTDY 3X11/4XC WELD CUP 41fAX1/4 TS POST, TYP. 3 5/8' IBGA STUD 0 16' O.C. BETWEEN TS POSTS 1/4 1 3/4'W e 1/4 M ANGLE e Aa I A r SCALE '/l = 1'-0' 7 , 4X4X1/4 TS POST (SEE I PLAN FOR LOCAlM) 4• I NOKIA CABINET I EA. WAY NOKIA CABINET /iUowm MAY BE USED FOR r5/16X6. ATTACHUENT L=9' R 3/4X10, L=1tl WELD CUP (EMBED NT 114 /4 O Sr�" 16'X16 PLINTIi O T 0.C. I EA WAY W/3-+4 u ------.------ 4 � B/S-1 FOR 7W, a SLFM REINFORCEMENT N c �. . METAL DECKING ELL 1 1/Y METAL DECKING i BM (W24X55) (5) 16 0 T EA WAY SCALE 1' = I' -Tr 14 I SLAB REINFORCEMENT SECTION SCALE: 1' = 1'-o' 1 8 1 MECHANICAL SCREEN SECTION - BR2 "' 3/40 X 2 11Y STUDS SCALE: Y = I I I NOKIA CABINET I I I I I UNLSIRUT TO STIR I I I wfixts, 1r9'-1f, f_------------� ml orx HILTI WA 1/Yf O 3' O.C., TYP, YXY NEOPRENE WASHED (1 ��riv ON TYP. EQUIPMENT PLATFORM SCALE: I- = 1•-tl 117 1'-T g ,r C 3/010, L-IG' - - - - W/ (4) 3/4'0 A.B. (EMBED 1V) I ® ® 1 4X4X1/4 Ts POST 70 4 — Ck I CONCRETE PLINTH I I PITCH POCKET II AT&T WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. a IS PRODUCE➢ fiE BY Ta OW10 AND ITS AFFILIXIM t$ "DIUVW OR USE of W DRAW % AN OR THE WORVATION C(NTA81m W IT 1S FORBDOEM WITHOUT THE W'RDTEN PEAIM ION OF THE OWNER. ;eae] Ail-VA9A I IE1F/15E � 11A1E 21 OCT03 CD REVIEW CONCRETE PLINTH DETAIL SCALE: 11/x = r-tl 16 22DCT03 CD FINAL SIRUCNRAL DESIGN Cam_ 1. ALL STRUCTURAL DESIGN CONFORMS TO REQUIREMENTS OF UBC-97 SNOW LOAD: 25psf WIND LOAD: WIND VELOCITY SOmph, EXPOSURE 'B' SEISMIC LOAD: ZONE 3, Z=0.3, SOIL SO, R=3.0 STRUCTURAL SIF7:L- 1. STRUCTURAL TUBES BE ASTM A50D GRADE B, Fy=46ksi 2. STRUCTURAL SECTIONS SHALL BE ASTM A36 Fy=36ksi 3. ALL BOLTS ARE ASTM A325N 4. ALL WELDING SHALL CONFORM TO AWS. ALL WELDS SWILL BE MADE USING LOW —HYDROGEN ELECTRODES WITH MINIMUM TENSILE STRENGTH OF 70ksi. 5. ALL STRUCTURAL STEEL SHALL BE GALVANIZED AND PAINTED TO MATCH THE EXISTING mum STEEL PAINT (UNO). 114 GAVE LIGHT GAUGE STEEL' 1 1. STEEL STUDS SHALL BE STANDARD C—SHAPED, 3 5/8' DEEP PUNCHED, WITH STIFFENED FLANGES, COMPLYING WITH ATM C955, Fy=33ksi, GA18. RANGE WIDTH 1 5/8' GALVANIZED. 2. FOR CONNECTIONS USE'STIFFCLUP CO CONNECTORS AS MANUFACTURED BY 'THE STEEL NETWORK. 3. USE 4—/10 SCREWS FOR EACH CONNECTION. CONCRETE sm AWE 1. COMPRESSIVE STRENGTH F'c=4,000pai IN 28 DAYS 2. DO NOT USE ADMIXURES CONTAINING CHLORIDE OR CHLORIDE SALTS. WEYERHAEUSER 3, USE THE 141HUW WATER-CEIE)f MTV. THE La 9 ALL NAVE A rm SLAY,¢ OF 4, PROVIDE A 5% AIR ENTRAWMW lJ L i y 5. REINFORCING STEEL SHALL CONFORM TO ASTM A515, GRADE 60 (Fy=60,000p ,,). NO BAR SS81 WELDING IS ALLOWED. OARS SHALL NOT BE FIELD BENT. FBA JOB MN18E11 RI FIOIISE 6. PROVIDE CONCRETE COVER OF 314' CLEAR " f— T � W 231176 eRKL 7. ALL CONCRETE SHOWN IN DRAWINGS SHALL BE PLACED IN ONE CONTINUOUS POUR. CHIMM BY: EIS B. EXISTNG CONCRETE SURFACE AONCENT ell GOTO 1lNCRLSIE' 1� li, ROVGt1RTkUj )/{ r•. 5 ADDRESS TO 31s' DEEP. THE �''E 514W.L 6E �Y cumm Alm!wm�p AqL., (A M - 33930 WEYERHAEUSER WAY 9TAL BE REMOVED FROM THE MI( OTORE CONCRETE PLAU:ING.- _ - FEDERAL WAY, WA 98001 9. CONCRETE SFWl BE PLACED WITH CARE AVOIDING DROPPING AND DUMPING OF LARGE AMOUNTS OF CONCRETE IN ONE PLACE YIELDED STUDS: SLEET TmE 1. STUDS SHALL BE MAJUFACTUREO FROM ASTN A108 STEEL. 13Y-TRU-WELIY OR 'NELSON. STRUCTURAL PLAN STRUCTURAL DETAILS 2. BEFORE WELDING STUDS TO STRUCTURE STEEL BEAMS, THE METAL DECK SHALL BE CUT STRUCTURAL NOTES OUT TO A DIAMETER OF 1 1/Y. THE STEEL PAINT SHALL BE GROUND OFF TO A CLEAN STEEL SURFACE SHEET MUM 3. WELDING OF STUDS SHALL BE EXECUTED IN STRICT CONFORMANCE WITH ALL AWS Dt.t C-i RE UIaEMETTS. S7 1 STRUCTURAL NOTES SCALE: NONE 1 20 PLDT s 1:1 Ex 4X4X1/4 TS EX. CONCRETE SLAB i7L 3fE3%1/iXP ROUGHEN EX. CONCRETE WED CUP 1/4•-3/6 DEEP FULL LENGTH 4%4XI/4 TS NEW CONCRETE SIM (MATCH EX. CONCRETE LEVEL) NEW 4X4X1/4 BETWEEN Pp5T5 3 6 I • 4' y ----�—�.--- I I NEW C I I EX METAL DECK 3X3X1/4, L=,v 1 I 16 I CONCRETE DETAIL SCALE s = r Lr 13 TS CONNECTION DETAIL SmI 19t - 1•-O• 17 PIPE MAST AS REWIRED PIPE CLAMP L4)M$/) (LjwI/4) 1/2• ALL THREADED ROD, TYP. 6X9X5/1 t 5/161 L-4 1 MECHANICAL SCREEN /6 BETWEEN 2-STUDS (DLL STUDS 2-STUDS 3/4WX4 1)i 5TUD$ 1 EA END) 0 T COtaD?M SLAB 0/4WX2 1/7 STUDS ---_ Pi L2X4X3/8 EA END 0 4 CONCRETE SLAB), y TYP. OF 4 { 1 3/4 A325N BOLT 1. do y 1• 7 p ` NEW 3 5/6 1Bd GALV S., 51UO, TYP. EX. 3 1/2- MTL PJ.Atl STUD, TYP. ANCHOR PLATE DETAIL wAm S = Lfj 14 PIPE ATTACHMENT DETAIL SCALE- 3' = 1'-016 4: it D.C. I I LJX4X3/8 BETWEEN I I 2-STUDS (DEL STUDS fIUD AS NOTED. WELD ONLY AFTER I I I EA END) CUFFING HOLE IN DECK TO AVOID WELD CONTANWITK)N I I I I L2X4X3/6 EA END METAL DECK I I I PIPE CW1P 1 I I I PIPE MAST AS i I REQUIREDWASHERS 1/2• ALL THREADED ROD. W/ LOCK O TA NUT DL STRUCTURAL IIEIJBQ! I I 1 1/ts µTILE DYb) VAIM OF METAL gEGK, GIFT HOLE BEFORE WDAW STUDS ;EcTIOa ANCHOR PLATE DETAIL SCALE S = V-v 15 PIPE ATTACHMENT DETAIL ScuE = 1'—p 19 ANTENNA SUPPLED BY OWNER; FNOTU 9TCH POCKET (OlJTUI ! 3/IrX6. L=d' CONTRACTOR TO INSTALL (VERIFY ANTENNA MOUNTING REQUIREMENTS PAINT ANTENNA AND MOUNT TO AND COORDINATE INSTALLATION WITH MATCH EX, ADJACENT SURFACE PROJECT MANAGER) (4) 1/fK DOLL Y EMBED TOP OF EX. MECH. SCREEN TOP OF PIPE r----� v — S►X1/C GALV SIL POST PIPE MOUNT ATTACHMENT, TYP, I QO 1- — — f I I Qo I 'l i FTC PIPE MAST AS REQUIRED 4, L --- J 3/16 EXISTING MECHANICAL SCREEN s• WALL CABLE BRIDGE COLUMN DETAIL SCAE' 3* 1S ANTENNA MOUNT SCALE: YC 1'-Gr 20 WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. ITIS PRODUCED SOLELY FOR USE BY THE OWNER AND US A1TIUATM REPRDDLOON OR USE OF THIS DRAWING AVD/OR THE INFORMATION CONTAINED IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. ER Al9WfflffLffA7Il'L— W6 � Ems) Ha-P'Ii0 (2N) 4 -N76 REIFASE M7E 210Cf03 CO RENEW zxocTD3 co FINAL WEYERHAEUSER I SITE NUBFR �ss61 PDV JOB NINBER w HdSE 231176 DIRM W. RKL CHEOTOD DI': EIS � sDE �obREss 33930 WEYERHAEUSER WAY L p R AY. WA 98001 �T SHEET TIRE STRUCTURAL DETAILS SHEET NUllffLt S-2 PLOT Somm 1:1 IF.M CU COPPER TYR TYPICAL C.O. CONDUIT ONLY DISCONNECT SWITCH Q GROUND ROD O METER BASE OJ JUNCTION BOX OT THERMOSTAT OS SMOKE DEFECTOR ® SPECIAL RECEPTACLE, AS NOTED -0--0- SWITCH GROUNDING NOTES: 1. ALL EXTERIOR CONNECTIONS TO BE CADWELD O.H. OVERHEAD O.C. ON CENTER GA GAUGE O.D. OUTSIDE DIAMETER MIN. MINIMUM CON. CONTINUATION EXIST. EXISTING WP WEATHERPROOF -i o- SURGE ARRESTOR FUSE 2. ALL INTERIOR 12 SOLID GROUND CONNECTIONS TO BE MECHANICAL TYPE WITH COPPER SHIELD. USE T&B 31007 CONNECTOR FOR i2 SOLID AT INTERIOR BUSES. USE ANDERSON CP-22 CRIMPTAPS TO STRANDED HALO GROUND. (USE COMPRESSION TYPE FOR ALL STRANDED CONNECTIONS). 3. MINIMUM BENDING RADIUS W. 4. NO SPLICES PERMITTED IN GROUND CONDUCTOR. 5. GROUND CONDUCTOR - #2 SOLID TINNED CU. 6. CONTRACTOR TO PROVIDE AND, INSTALL INTERCONNECTS FROM GROUND GRID TO STRUCTURES. 7. ANY PENETRATIDNS THRU SHELTER WALL SHALL BE 45DEG DOWNWARD TO OUTSIDE, AND SHALL BE SEALED TO PREVENT LEAKAGE B. ALL BURIED CONNECTIONS TO BE CADWELD TYPE GY OR GA CONNECTIONS. 9. STAGGER CONNECTION POINTS A MINIMUM OF G' WHEN MORE THAN ONE CONNECTION IS REQUIRED. 1. INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SFW1 BE COMPLETED IN COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70. AND THE STATE OF WASHINGTON LAWS, RULES AND REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH SPECIFICATIONS PER AS.T.M. B 231, B 400, I.C.EA S651-401, I.C.EA PB1-570, & LOCAL PUD. 2. PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS 3. UNDERGROUND CONDUIT SWJJ_ BE RIGID POLYVINYL CHLORIDE CONDUIT; SCHEDULE 40, TYPE 1, CONFORMING TO UL ARTICLE 651; WESTERN PLASTICS OR CARTON MANUFACTURER COUPLINGS SHALL BE SUP -ON, SOLVENT SEALED T PIPE; SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT. ALL BENDS SHALL BE 36-INCH MINIMUM RADIUS. 4. CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. COUPLINGS SWJl BE RIGID STEEL AND COMPRESSION TYPE FOR EM.T. SET SCREW FITTINGS ARE NOT PERMITTED, FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. 5. WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO SPLICES ALLOWED. EL NEUTRAL SHALL BE COLOR CDDED, INSULATION SHALL BE CROSS -LINKED POLYETHYLENE. 7. TRENCH BACKFILL SHALL BE NATIVE MATERIAL COMPACTED TO 90% MDD PER AS.T.M. D 1557 MODIFIED PROCTOR ELECTRICAL NOTES ACE TO GROUND X'E UNDTAR, EQUIPME E, ETC) MHIESS STFFL SERF-TAPP.NC SCREWS 51 WITH STAR WASHERS (C NUT SIDE) AND DOUBLE LUG (ON HEAD COMPRESSION CONNECTORS ND WIRE CONNECT PER CROUKOWG PLA4 SECTION EQUIPMENT GROUND CONNECTION SCALE: NONE ISOMETRIC NOTES, R L W JUMPER W1 SW BARREL 9DL OR COMPRES (TLUGS OS OR 5407}SUSE TAR 1. ALL HARDWARE STAINLESS STEEL INCLUDING WASHERS, LOC104A5HER5, AND SHEET MTL SCREWS TO SECURE BELLVILLES; COAT ALL SURFACE WITH TO EXTERNAL GROUND BAR BY GENERAL CONTRACTOR KOPR-SHIELD BEFORE MATEING. 2. FOR GROUND BOND TO STEEL ONLY: INSERT COAXIAL GROUND KITS W/ LONG BARREL COMPRESSION PROVIDE UNISTRUT OR 0 A TOOTH WASHER BETWEEN LUG AND STEEL, LUGS W/ TWO (2) IAA SCLTS AND LOCK WASHERS APPROPRIATE MOUNTING COAT ALL SURFACES WITH KOPR-SHIELD. SIMRAR TO ANDREN 3241W-9- FURNSHED BY AT&T @ HARDWARE INSTALLED BY CONTRACTOR 3. ALL HOLES ARE COUNTERSUNK K6 . 4'z 20'z ]; lhk COPPER GROUND BAR SUPPLY 4. ALL LUGS TO BE DOUBLE -LUGGED 5. BUS AND INSTALL BY GENERAL CONTRACTOR BARS: 4'X2UW4' COPPER BY NEWTON, OR no B TYP NNL MOUNTING BRACKET EQUAL O 00 0 0 0 0 0 0 0 0 0 o a 0000 00 o0 C. a o 0 0 0 0 0 0 1YB BOLT C7 1-3/4 44— 1 �� -D60LATOR AT ALL WALL PENETRATIONS. TYP. 12 AWG 7NNE0 SOLID COPPER CONDUCTOR CONNE� CTIONSTO GROUND BAR CAl AEID TO GRGUND BAR & CADWELD CONYF_CTON la EXTERIOR GROUND SYSTEM GROUND BAR DETAILS SCALE: NTS 9 PANEL GROUNDING KIT; INSTALL PER MFR INSTALLATION INSTRUCTIONS GROUND PANEL MOUNT KIT. INSTALL PFR WR 1RSTALIATION RRSTRIICRION COAX CABLE JUICER DIRECTIONAL PANEL ANTENNA COAX GROUNDING KIT; INSTALL PER MFR INSTALLATION INSTRUCTION GROUND BAR I ANTENNA & COAX GROUNDING SCHEMATIC SCAT F: W = I'-d' 1 6 1 LIGHT FIXTURE LIGHT SWITCH & OUTDOOR ELECTRICAL OUTLET 'HOFFMAr TELEPHONE BOX 20' GALV SR CONDUIT CONDUIT TO EOU9'MERT CABINETS, TYP. OF 2 , T.O. ROOF 3RD FLOOR TELEPHONE/ELECTRICAL ROOM SCALE NONE 14 1 ONE LINE DIAGRAM ,,-2DOAMP 10 POWER PANEL, MOUNT PER NEC SERVICE DISCONNECT, MOUNT PER NEC ._1_ 30' GALV SR CONDUIT r.CH MEn=o TER 3RD FLOOR ELECTRICAL CLOSET SCALE: NITS B % DESCRIPTION SEE REFERENCE GROUND ANTENNA WITH COAXIAL GROUNDING KIT TO GROUND BAR e G09 GROUND EQUIPMENT CABINET TO MGB 4 G1 GROUND POWER/TELCO CONNECTION TO MGB O16 GROUND CABLE GUIDE TO GROUND BAR KEY NOTE LEGEND GB, TYP. ANTENNA GROUND, j I DESCRIPTION SEE REFERENCE M.D GROUND TO EX. WATER WIN OR BUWC STEEL 3wo 'PROPOSED MASTER GROUND TEAR 0 EQUIPMENT ,21 'PROPOSED GROUND BAR 9 I KEY NOTE LEGEND II NOTES 1. GROUND COAXIAL CABLE RUNS AT ANTENNAS W/ APPROVED COWR GROUNDING KIT & UNIVERSAL ANGLE ADAPTORS. GROUND COAXIAL CABLE RUNS AT ANTENNAS AT ITS DESIGNATED GROUND BAR, WHICH IS ULTIMATELY TIED TO THE MASTER GROUND BAR. 2. ALL EXPOSED GROUND LEADS GREATER THAN 1IT IN LENGTH SHALL BE ENCASED IN Yt'W FLEX PVC CONDUR. 3. ALL STANDARDS, NOTES AND DRAWINGS ON ELECTRICAL SHEETS WERE PROVIDED BY WESTERN WIRELESS. AN ELECTRICAL ENGINEER WAS NOT RETAINED T COMPILE THE ASSOCIATED INFORMATION, I MASTER GROUND BAR GROUND WIRE COPPER GROUND ROD 1_ (MGB) if x4'x24' COPPER 1 CADWELD Wx -1--r GROUND BAR (GB) Yi x4'x1Y O' GRO COPPER CLAD STEEL Q OR Yi x4'x20' COPPER MECHANICAL CONNECTION GROUNN D ROD GROUNDING DIAGRAM A- 'FAD b EL �00 =RAL DEG GROUND TEST WELL SCALE: %C = 1'-0' ATaT �-i WIRELESS SERVICES AT&T WIRELESS SERVICE 14500 NE 87TH STREET REDMOND, WASHINGTON 98052 PHONE: 425.702.3697 THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER W TTS AEFpµTES. REPRODUCTION OR USE OF THIS O Wfh'',' AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. ,[�faCT'8 SBA'17TE } ]m 4TtWa!' Seas) 447-%YU 49 [YOU) 443-Y196 I 1 REFASE DUE 03 CD REVIEW 220OCTCT03 CD FINAL SIDE NWE I 'WEYERHAEUSER SITE N mn SS81 PWA JOB NUI®R N FIOOg 231176 DRABN W.RKL tlECI® BY: EJS SIZE ADDRESS 33930 WEYERHAEUSER WAY FEDERAL WAY, WA 98001 52EET 71RE ELECTRICAL NOTES & DETAILS GROUNDING DIAGRAM & DETAILS %w NUMBER E1 PIDT SCALE: 1:1