12-104014CITY OF t Federal Way October 26, 2012 Allison Zike RealCom Associates LLC 14432 SE Eastgate Street, Suite 260 Bellevue, WA 98007 CITY HALL L', 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com RE: File #12-104014-00-UP; PROCESS III —'PROJECT APPROVAL' T-Mobile — SE04693 Mirror Lake, 316171" Avenue South, Federal Way Dear Ms. Zike: The Community and Economic Development Department has completed administrative land use review of the proposed Personal Wireless Service Facility (PWSF) improvements located at 31517 1" Avenue South, Federal Way. The applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) by replacing six (6) existing antennas and adding three (3) new antennas, for a total of nine (9) antennas on the facility. The proposed upgrade is to prepare the site for the latest and next generation of technology. The Process III Master Land Use (MLU) application submitted August 29, 2012, is hereby approved based on the enclosed findings of fact, incorporated into this decision in full, and the following conclusions based on those facts: l . The proposal is consistent with the comprehensive plan; 2. The proposal is consistent with all applicable provisions of Federal Way Revised Code (FWRC); 3. The proposal is consistent with the public health, safety, and welfare; 4. The streets and utilities in the area of the subject property are adequate to serve the anticipated demand from the proposal; 5. The proposed access to the subject property is at the optimal location and configuration; and 6. Traffic safety impacts for all modes of transportation, both on and off site, are adequately mitigated. The remainder of this letter outlines the land use review process required for this particular site improvement; summarizes the State Environmental Policy Act (SEPA) process; and provides other procedural information. This land use decision does not authorize initiation of construction activities. REVIEW PROCESSES REQUIRED Pursuant to FWRC 19.15.030(3), improvements and/or additions to an existing developed site that are not exempt from SEPA shall be processed under Use Process I11. The Director of Community and Economic Development will make the initial land use decision based on written comments and information gathered during site plan review. Any appeals of the decision will be decided by the Hearing Examiner after a `public hearing. Ms. Zike October 26, 2012 Page 2 SEPA PROCESS The City of Federal Way issued a Determination of Nonsignificance (DNS) on October 9, 2012, pursuant to Washington Administrative Code 197-11-350. Following review of the environmental checklist, the city determined the proposal would not have a probable significant adverse impact on the environment, and an Environmental Impact Statement would not be required, and no SEPA based mitigation was necessary. REQUESTS FOR CHANGE OF VALUATION Any affected property owners may request a change in valuation for property tax purposes, not withstanding any program of revaluation. APPROVAL DURATION Unless modified or appealed, the Process III decision is valid for five years from the date of issuance of the decision. Time extensions to the decision may be requested prior to the lapse of approval following the provisions listed in FWRC 19.15.110. APPEALS The effective date of issuance is three calendar days following the date of this letter, October 29, 2012. Pursuant to FWRC 19.65.120, this land use decision may be appealed by any person who submitted written comments or any person who has specifically requested a copy of the decision. Any appeal must be in the form of a letter delivered to the Community and Economic Development Department with the established fee and within 14 days after the effective date of issuance of this decision, or November 12, 2012. The appeal letter must contain a clear reference to the matter being appealed and a statement of the factual findings and conclusion of the Director disputed by the person filing the appeal. The Federal Way Hearing Examiner will hear any appeals of the Process III decision. CLOSING This land use decision does not waive compliance with future City of Federal Way codes, policies, and standards relating to this development. If you have any questions regarding this decision, please contact Becky Chapin, Assistant Planner, at 253-835- 2641 or rebecca.chapin@cityoffederalway.com. Sincerely, Isaac Conlen Planning Manager for Patrick Doherty, Director enc: Exhibit `A' Statement of Findings and Conclusions Approved Plan Set c: Becky Chapin, Assistant Planner 12-104014 Doe. I.D. 62373 FILL CITY OF' Federal Way Exhibit A Findings for Project Approval Federal Way Revised Code (FWRC) Chapter 19.65 `Process III Project Approval' T-Mobile — SE04693 Mirror Lake, File 12-104014-00-UP The Planning Division hereby presents the following analysis to the Director of Community and Economic Development pursuant to content requirements of the Process III written decision as set forth in Federal Way Revised Code (FWRC) 19.65.100(4). Proposal — The applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. The proposal also includes associated upgrades to the ground equipment within the existing equipment shelter area. Site Conditions — The existing PWSF is located on a 150-foot monopole on a site owned by South King Fire & Rescue at 31617 1" Avenue South, Federal Way. The ground equipment is located within an existing shelter; no changes are proposed to modify the equipment shelter location. Comprehensive Plan and Zoning — The City's Comprehensive Plan designation is Single Family, High Density and the zoning is Single Family Residential (RS 9.6). PWSFs are permitted in the RS zone pursuant to FWRC 19.200.190. 4. Review Process — The replacement and addition of antennas to the existing PWSF is not exempt from State Environmental Policy Act (SEPA) review and is subject to Process III `Project Approval' review. State Environmental Policy Act (SEPA) — The proposal is not exempt from environmental review pursuant to Washington Administrative Code 197-11-800(25)(a)(iii). The city utilized the Optional DNS process as allowed by SEPA Rules. A combined Notice of Application and Optional Determination of Nonsignificance was issued September 21, 2012. No comments were received during the integrated comment period. The city's Responsible Official issued a Determination of Nonsignificance October 9, 2012. The threshold determination appeal period ended October 23, 2012, with no appeals submitted to the Federal Way City Clerk. 6. Public Notice — Pursuant to Process III and SEPA regulations, a Notice of Land Use Application and Optional DNS were published in the Federal Way Mirror, posted at two locations at the subject site, and displayed on the designated city notice boards on September 21, 2012. Notices were also mailed to property owners within 300 feet of the subject property. No comments were received on the land use application or SEPA DNS notice. 7. Prioritized Locations — The applicant proposes to locate the PWSF on "Existing broadcast, relay and transmission towers," which is the second priority location of the five prescribed in FWRC 19.255.010(4). Higher prioritized location, Structures located in the BPA trail, is not feasible as this proposal is an upgrade to an existing facility. There are no alternative BPA towers in the proposed _ vicinit~y_._Stafffind_s__the applicant has met _the -burden _to_utilize.the second: prioritized: location, The antenna modifications should provide the full benefit of service to the area. PWSF Development Standards — PWSFs located on existing structures shall meet development standards prescribed in FWRC 19.255.020(1). The following are staff responses to each criterion: a. (ii) The PWSF exceeds the minor facility thresholds for number of antennas and size, but creates no more adverse impacts than a minor facility. Based on site photos and detailed drawings, the proposed addition will be installed in the same manner as the previously approved antennas and the visual impact will be unchanged. b. The combined antennas will not exceed 15 feet above the existing rooftop facility. No height increase is being proposed. C. This section does not apply as the proposed PWSF is not in a right-of-way. d. The proposed antennas will be painted to match existing conditions. The impacts to surrounding uses will be no greater than the existing facility. e. The proposed size and number of the antennas are necessary to meet coverage objectives as depicted in the project narrative provided by applicant. f. The existing ground equipment meets current regulations. Minor additional equipment is to be added to an existing cabinet. The footprint of the facility will not be enlarged and will meet the setback requirements. Screening Standards — PWSFs are required to be screened using best available technology and design. The proposed antennas will be screened and painted to match the existing antennas. These measures appropriately mitigate visual impacts of the facility, cause no adverse cumulative effects, and meet aesthetic standards set forth in FWRC 19.255.020(1)(d). 10. Electronics Equipment Standards — No material expansions or changes to the architectural design of the enclosure are proposed. Therefore, these changes are exempt from PWSF standards set forth in FWRC Chapter 19.255 and are permitted outright with no further regulatory action required pursuant to FWRC 19.255.010(3)(g). 11. Security Screening — The PWSF includes existing structure and fencing; no new fencing or expansion of existing fencing is proposed. 12. Cumulative Effects — The city must consider the cumulative visual effects of the PWSF mounted on an existing structure in determining whether additional permits may be granted so as to not adversely affect the visual character of the city. Based on the plans and photo -simulations of the proposed modifications, the PWSF will not adversely affect the visual character of the city. The additional antennas will be camouflaged through best available technology and design and will have less of an impact than creating a new PWSF site. 13. Conditions of Approval — The following conditions of approval shall be a component of the Process III land use decision: r Prior to any site work, the applicant shall obtain an electrical permit from the city's Department of Community and Economic Development. 14. Process III Decision Criteria — Based on the above findings, staff has determined the proposal is consistent with applicable site plan approval criteria required for Process III `Project Approval' pursuant to the following FWRC 19.65.100(2) items. Staff responses (italicized) follow each criterion: a. It is consistent with the comprehensive plan; -The proposal is consistent with the following Federal Way Comprehensive Plan goals and Findings for Project Approval T-Mobile — SE04693 Mirror Lake Page 2 File 12-104014-00-UP/Doc. I.D. 62376 PUG] — Work with private utility companies to allow them to provide full and timely service that meets the needs of the city's residents and businesses, both present and future. PUG2 — Work with private utility companies to allow them to provide service in a way that balances cost-effectiveness with environmental protection, aesthetic impact, public safety, and public health. PUP17 — The city should require that site specific utility facilities such as antennas and substations be reasonably and appropriately sited and screened to mitigate adverse aesthetic impacts. b. It is consistent with all applicable provisions of this title; The site plan has been reviewed under FWRC Title 19, "Zoning and Development Code, " with specific attention to the following divisions and/or chapters: Division 1, Administration; Chapter 19. 65, Process III Project Approval; Chapter 19.200, Single Family Residential (RS); and Chapter 19.255, Personal Wireless Service Facilities. c. It is consistent with the public health, safety, and welfare; No adverse impacts are anticipated as a result of the proposal. The PWSF has received approval from South King Fire & Rescue. The Process Ill ML U application has been reviewed under SEPA, FWCP, and applicable provisions of the FWRC. d. The streets and utilities in the area of the subject property are adequate to serve the anticipated demand from the proposal; The city's Traffic Division has determined the PWSF will not require concurrency review and will not adversely affect the current level of service. The Lakehaven Utility District has determined no sewer or water improvements are required for the PWSF. e. The proposed access to the subject property is at the optimal location and configuration; The facility is an existing site and no changes are proposed to the access points to the facility. f. Traffic safety impacts for all modes of transportation, both on or offsite, are adequately .mitigated. As the facility is unmanned, this criterion is not applicable. These findings shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this development. Prepared by: Becky Chapin, Assistant Planner Findings for Project Approval T-Mobile — SE04693 Mirror Lake Date: October 23, 2012 Page 3 File 12-104014-00-UP/n« I.D. 62376 CITY OF Federal Way October 9, 2012 Allison Zike RealCom Associates LLC 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 CITY HALL 33325 8th Aven uth Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com RE: File #12-104015-00-SE; ENVIRONMENTAL THRESHOLD DETERMINATION T-Mobile - SE04693 Mirror Lake, 3161715t Avenue South, Federal Way Dear Ms. Zike: The city and jurisdictional agencies have reviewed the environmental checklist submitted with the T-Mobile — SE04693 Mirror Lake Process III Master Land Use (MLU) application. It has been determined that the proposal will not have a probable significant adverse impact on the environment. As a result, an Environmental Impact Statement (EIS) is not required to comply with the State Environmental Policy Act (SEPA). A copy of the Determination of Nonsignificance (DNS) is enclosed. The Optional DNS Process was used to review this proposal. The 14-day comment period required by SEPA rules ran concurrently with the public comment period associated with the notice of land use application, which began on September 21, 2012, and ended October 8, 2012. The city did not receive written comments regarding the MLU application or environmental checklist. Pursuant to Washington Administrative Code (WAC) 197-11-355, a second comment period is not required upon issuance of the DNS. The enclosed DNS was issued on October 9, 2012. The city will provide a copy of the DNS to the Department of Ecology, agencies with jurisdiction, Puyallup and Muckleshoot tribes, and anyone requesting a copy. All final determinations may be appealed within 14 days following the issuance of the DNS. No licenses, permits, or approvals will be issued until completion of the appeal period, which ends October 23, 2012. The decision not to require an EIS does not grant the license, permit, or approval you are seeking from the city, The environmental record is considered by the decision maker(s) and conditions will be imposed to reduce identified environmental impacts, as long as the conditions are based on adopted and designated city policy. After a final decision has been made on your proposal you may, but are not required to, publish a Notice of Action as permitted in RCW 43.21 C.075. The Notice of Action sets forth a time period after which no legal challenges regarding the proposal's compliance with SEPA can be made. The city is not responsible for publishing the Notice of Action. Questions regarding the PWSF's environmental review component should be directed to me at 253-835-2641 or rebecca.chapin@cityoffederalway.com. Sincerely, .�Wv� Becky Chapin Assistant Planner enc: DNS Doc, I.D. 62364 CITY 6F Federal Way ENVIRONMENTAL DETERMINATION OF NONSIGNIFICANCE (DNS) T-Mobile — SE004693 Mirror Lake File No. 12-104015-00-SE FILE' Proposal: Applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) co - located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within the fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Location: 31617 151 Avenue South, Federal Way Lead Agency: City of Federal Way Community and Economic Development Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 The Responsible Official of the City of Federal Way hereby makes the following decision based upon impacts identified in the environmental checklist, Federal Way Comprehensive Plan, Federal Way Revised Code, 2009 King County Surface Water Design Manual, and other municipal policies, plans, rules, and regulations designated as a basis for exercise of substantive authority under the State Environmental Policy Act Rules pursuant to Revised Code of Washington (RCW) 43.31 C.060. The lead agency for this proposal has determined that it does not have probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) is not required under RCW 43.21C.032(2)(c). This decision was made after review of a gompleted environmental checklist and other information on file with the lead agency. This information is available to the public on request. This DNS is issued after using the optional DNS process in WAC 197-11-355. No written comments were received in response to the 14 day comment period that ended October 8 2012. There is no further comment period on the DNS. You may appeal this determination to the Federal Way City Clerk, no later than 5:00 p.m. on October 23, 2012, by a written letter stating the reason for the appeal of the determination. You should be prepared to make specific factual objections. Responsible Official: Isaac Conlen, Planning Manager for Patrick Doherty, Director of Community and Economic Development Address: Date Issued: 33325 8`h Avenue South, Federal Way, WA 98003 Doe, LD. 62361 4k OF Fed40';:�� eral Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8th Avenue South Federal Way WA 98003 253-835-7000; Fax 253-835-2609 www.citvoffederalway.com DECLARATION OF DISTRIBUTION I, hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) ❑ Notice of Land Use Application & Optional DNS/MDNS ❑ FWRC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Public Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was Amailed ❑ faxed Me -mailed and/or ❑ posted to or at each of the attached addresses on _1� 2012. � Mbt Project Name tLXA _ File Number(s) Signature7! Date /6-9'a0/J K:\CD Administration Files\Declaration of Distribution.doc/Last printed 1/12/2012 2:20:00 PM CITY OF Federal Way ENVIRONMENTAL DETERMINATION OF NONSIGNIFICANCE (DNS) T-Mobile — SE004693 Mirror Lake File No.12-104015-00-SE Proposal: Applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) co - located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within the fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Location: 31617 lst Avenue South, Federal Way Lead Agency: City of Federal Way Community and Economic Development Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 The Responsible Official of the City of Federal Way hereby makes the following decision based upon impacts identified in the environmental checklist, Federal Way Comprehensive Plan, Federal Way Revised Code, 2009 King County Surface Water Design Manual, and other municipal policies, plans, rules, and regulations designated as a basis for exercise of substantive authority under the State Environmental Policy Act Rules pursuant to Revised Code of Washington (RCW) 43.31 C.060. The lead agency for this proposal has determined that it does not have probable significant adverse impact on the environment and an Environmental Impact Statement (EIS) is not required under RCW 43.21C.032(2)(c). This decision was made after review of a completed environmental checklist and other information on file with the lead agency. This information is available to the public on request. This DNS is issued after using the optional DNS process in WAC 197-11-355. No written comments were received in response to the 14 da comment period that ended October 8 2012. There is no further comment period on the DNS. You may appeal this determination to the Federal Way City Clerk, no later than 5:00 p.m. on October 23, 2012, by a written letter stating the reason for the appeal of the determination. You should be prepared to make specific factual objections. Responsible Official: Isaac Conlen, Planning Manager for Patrick Doherty, Director of Community and Economic Development Address: 33325 8tb Avenue South, Federal Way, WA 98003 Date Issued: October 9. 2012 Doc. la 62361 Tamara Fix From: Tamara Fix Sent: Tuesday, October 09, 2012 12:20 PM To: 'ECY RE SEPA UNIT' Cc: Gordon Goodsell; 'basbury@lakehaven.org'; Chris Ingham Subject: T-Mobile Mirror Lake DNS Attachments: Tmobile Mirror Lk DNS.pdf Attached is the DNS for the T-Mobile Mirror Lake project in the City of Federal Way. This is being issued on October 9, 2012, and the Assistant Planner for the project is Becky Chapin, 253-835-2641, rebecca.cha in cit offederalwa .cam. SEPA Optional DNS Notice and Checklist to the following agencies andtribes MUCKLESHOOT INDIAN TRIBE BRANDON REYNON ATN: ENVIRONMENTAL REVIEWER PUYALLUP TRIBE OF INDIANS 39015 172 NDAVE SE HISTORIC PRESERVATION DEPT AUBURN WA 98092 3009 E PORTLAND AVE TACOMA WA 98404 SOUTH KING FIRE & RESCUE 31617 1 ST AVE S FEDERAL WAY WA 98003 DEPT OF ECOLOGY ENVIRONMENTAL REVIEW SEC PO BOX 47703 OLYMPIA WA 98504-7703 sepaunit@ecy.wa.gov LAKEHAVEN UTILITY DIST PO BOX 4249 FEDERAL WAY WA 98063 31919 is' Ave S, Suite 101 1 Federal, way, WA 98003 1253.925.5565 1 253.925.5750 (f) Affidavit of Publication Rudi Alcott, being first duly sworn on oath, deposes and says that he is the Publisher of The Federal Way Mirror, a weekly newspaper. That said newspaper is published in the English language continually as a weekly newspaper in Federal Way, King County, Washington, and is now and during all of said time has been printed in an office maintained by the aforementioned place of publication of said newspaper. That the annexed is a true copy of a legal advertisement placed by City of Federal Way - Community Development Department as it was published in regular issues (and not in supplemental form) of said newspaper once each week for a period of one consecutive weeks(s), commencing on the 21 st day of September 2012, and ending on the 21 st day of September 2012. both dates inclusive, and that such newspaper was regularly distributed to its readers during all of said period. That the full amount of the fee charged for the foregoing publication is the sum of S 144.20, which amount has been paid in full, or billed at the legal rate according to RCW 65.16.090. Subscribed to and sworn before me this 1 st day of October 2012. Notary Public in and for the State of Washington, Residing at Federal Way NOTARY w U, PUBLIC ; z = r 6,; •� - ti • -y-. •r A5.•- rri �Or A Federal Way NOTICE OF LAND 115E APPLICAriON AND NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFfCANCE (DNS) Project Name; i-Mobile. - SE04693 Mirror lake Project Description: Proposal to upgrade an exist- ing Personal Wireless Service Facility rp4VSF) co - located on a 150-foot mo+lopule by replacing six (6) existing antennas and adding three ;3) new aln- tennas for a total of nine (9) ant?ones. Associated upgrades 10 the equipment cabinet within a fenced equipment shelter area are also included. Applicant: Allison like, Rea[Gorn Associates. 14432 SE Eastgate Way, Suite F60, Bellevue. WA 9R0177 Project Location; 1617 1st Avenue South. Feder 11 Warr Hate Application Received: Auqust 29, 2012 Date Determined Complete: August 29, 2012 D a I e 0 f N o t 1 c e o f Application: September 21, 2012 Comment Due Date: October 8, 2012 Environmental Review: Based upon review of a ::ompleted environmental checklist and oilier inf6r- matien on fife with the City. it is fikelp that the City of Federal Wav will determine that the project will not have a probable significant adverse impart ❑n the environment and expects to issue a Determina- tion of Nohsignificanee (DNS) for this project. The optional DNS process in WAC 197-ti-355 is betrlo used. This may be your only opportunity to coin- meet on the environmerilal impacts of the pro- posed project. The proposal may include mitiga- tion measures under applicable codes, and the re- v{ew,process may incorporate or require mitigation measures regardless a, 'Whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for the specif- ic proposal maV be obtained upon request. Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable environmental impacts Comments must he submitted by the date noted above, Permits Required by This Application: Master Land Use Process III (Fife =12-104014Lie.) and State Environmental Policy Act Tnreshold Determi• nation {File ifl 2- 104 01 5-S E I Other Permits Known at this Time and Not In- cluded in This Application: Electrical Permit Existing Environmental Documents: None Relevant Environmental Documents Are Avail• able at the Address Below: Yes Development Regalatiuns to Be Used for Project Review Known at this Time: Federal Wav Rewser,'' Code Title 14. 'Environmentai Policy and Title 19 Zoning and Development Code.' Public Comment & Appeals: Any person play srtb- mit written comments on the land use application or the environmental impacts of the proposal to the Director of Community and Economic Devetop- menl by 5:00 p in an October 8, 2012. Onfv per- sons who submit .written comments Io the Ofrector (address balotiv) or specifically request a copy of the decision, play appeal the decision. However. JAY Interested patty may appeal rile environmental threshold determination. Details of appeal proce- dt:res for the requested land use decision will be irkciuded with the written decision issuance o; Final Environmental Deterfnination The final Determination of Nonsignificance may be issued wilhoul a second comment period, unless tilftely comments identify probable significant ad- verse impacts that were not Considered by the No- tice of Outioilat Determination of Nonsignificance A copy of the Determination of Nonsigniflcance may be obtained upon reciiest. Availability of Fife: The official protect file Is avail- ahle for public review al the Department of Com- munity and Economic Development, 33325 8th Av- enue South Federal Way. WA 98003.6325. Staff Coutact: Becky Chapin, Assistant Plannet, 253.835 7,641 FWM1935 Date Published; September 21, 2102 O c� N C f0 Z �Y ca ID dN �'i+ W 0- w mli ° aD CO+• c6 co 4 1 O. i F o o).C8 c a� L f _ .q U') co a U h fu 0 � c°`m C t 0 N N O w ' a o O (I ; p) t) CL LL r D n� � N C O 5 1 `�°� a -0 N N j,, rn N 0 E �=a = L) G N LL N N O O U LL fA w (6C13 N 0.2 C U C O O N � O o a>cm_c �cn caQ 3 Co --- �S N J N S NI GNE —' U) C/) M ■ �� C/) 0 U) �. f M a, x L C0- O ui U) CD -' \ n� � j M� S (n W 2 � f Cl) Z O � N U)MS �d - o�� 7 �1 FILE CITY OF 40 Federal Way NOTICE OF LAND USE APPLICATION AND NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: T-Mobile — SE04693 Mirror Lake Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Project Location: 31617 Is'Avenue South, Federal Way Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012 Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012 Environmental Review: Based upon review of a completed environmental checklist and other information on file with the City, it is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to comment on the environmental impacts of the proposed project. The proposal may include mitigation measures under applicable codes, and the review process may incorporate or require mitigation measures regardless of whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for the specific proposal may be obtained upon request. Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable environmental impacts. Comments must be submitted by the date noted above. Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State Environmental Policy Act Threshold Determination (File # 12-104015-SE) Other Permits Known at this Time and Not Included in This Application: Electrical Permit Existing Environmental Documents: None Relevant Environmental Documents Are Available at the Address Below: Yes Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title 14, `Environmental Policy' and Title 19 `Zoning and Development Code.' Public Comment & Appeals: Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of Nonsignificance may be obtained upon request. Availability of File: The official gproject file is available for public review at the Department of Community and Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325. Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 Published in the Federal Way Mirror on September 21, 2012. Doc, LD. 62208 N U 9 N C C f0 d N rnu N CJ O x 0 T N li N C4) C C C'u 6 3 U y x N N N (q (6 Ilr j V m d of c0 Q C�N Ul L N >E' Q N w o N� N w C cClu C L O IDIL d Q wL so C U) cm N N � C (D F . N Y T a-o N E >' cc0)" V L ani F a 7 :U C -C U (0Adh N a C U- .••.-O f6 O C N OCL Z N L O (a N C m L) CL (n (0 Q . \W/ i J L 0 L L —C 0 CO > Q 0 N ♦W VJ A Qc) M 0 N'l a LLJ � Q r Q Q Ln Q T- T--- C) r Q N LL W T S N F- N z S NI (INZ J F- C+1 cr): F- _ F- cn -N v� r CO i M z JN ` F- N - - Cl) J f i 04 - ' i l i i 44k CITY Federalo. Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8th Avenue South Federal Way WA 98003 253-835-7000; Fax 253-835-2609 www.cityoffederalway.com DECLARATION OF DISTRIBUTION I, hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) Notice of Land Use Application & Optional DNS/MDNS ❑ FWRC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Public Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was ,mailed ❑ faxed l[e-mailed and/or ❑ posted to or at each of the attached addresses on 2012. Project Name �� d w L ► rrQ r File Number(s) _ ]a r% 6 Yfl 15 - SF Signature —1 Date g--'2D /c) K:\CD Administration Res\Declaration of Distribution.doc/Last printed 1/12/2012 2:20:00 PM CITY OF Federal Way NOTICE OF LAND USE APPLICATION AND NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: T-Mobile — SE04693 Mirror Lake Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Project Location: 31617 1 `Avenue South, Federal Way Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012 Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012 Environmental Review: Based upon review of a completed environmental checklist and other information on file with the City, it is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to comment on the environmental impacts of the proposed project. The proposal may include mitigation measures under applicable codes, and the review process may incorporate or require mitigation measures regardless of whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for the specific proposal may be obtained upon request_ Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable environmental impacts. Comments must be submitted by the date noted above. Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State Environmental Policy Act Threshold Determination (File # 12-104015-SE) Other Permits Known at this Time and Not Included in This Application: Electrical Permit Existing Environmental Documents: None Relevant Environmental Documents Are Available at the Address Below: Yes Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title 14, `Environmental Policy' and Title 19 `Zoning and Development Code.' Public Comment & Appeals: Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of Nonsignificance may be obtained upon request. Availability of File: The official project file is available for public review at the Department of Community and Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325. Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 Published in the Federal Way Mirror on September 21, 2012. oa. Ln. 62208 m C 75 (p rn T cc -X C U D m LL m U101,16 O� C C cc N 7 U E2 X a)N 0 c6 �U w d C1 l9 Q N C U � fa Or)C- F�r'y N Ltf N >. c Nw N E p NNU n= = 4) cm _d N � C N E -x cmd_0 m N F a� � na) 7 = C 7 U O f6 m p C LL to w v� y N Co (6 .M U C U C -0 CL 0!E N C to - U a to ca < § (D cu J O L 0 U) M a, O � C� C: > � Q O W U] a) M O F— a QL] � ca LL { CCL G Y �f W a O LL 'w D VJ co 46 T C) lO CDT Q T O N O N T O O N U- O a E ,r, S N N S NI ONZ � J � cn , � f { CO fp' m U) z _ U R _ M Z i A"d Z o ' N _ N71-Cl'd H� �I n ' '{v d of � 1 i 4 { i SEPA Optional DNS Notice and Checklist to the following agencies andtribes MUCKLESHOOT INDIAN TRIBE BRANDON REYNON DEPT OF ECOLOGY ATN: ENVIRONMENTAL REVIEWER PUYALLUP TRIBE OF INDIANS ENVIRONMENTAL REVIEW SEC 39015 172ND AVE SE HISTORIC PRESERVATION DEPT PO BOX 47703 AUBURN WA 98092 3009 E PORTLAND AVE OLYMPIA WA 98504-7703 TACOMA WA 98404 sepaunit@ecy.wa.gov SOUTH KING FIRE & RESCUE 31617 1 ST AVE S FEDERAL WAY WA 98003 LAKEHAVEN UTILITY DIST PO BOX 4249 FEDERAL WAY WA 98063 Parcel Map and Data G;`27 i+R9U7y U f 27 L+f 5+2:52 i4'27 C+R92R2 y 2Np Ltd S ' S9 8T}4 ST q df27UfuUd!^ U827049706 L4'27UR9U30 � �• �-. _,1UR99fi Jl271JRSl79ri SW 31€TH ST CV2704907f + "",`—.— 0 210 33f�39UU/U, 33ls3UU70U Ui17U•Tu2+"ri S31frN'Pt ` Federal Way '•'`'� ._ �j ��� SSfSjUL29U �cR � �'j 33,`S3UU2fi1 'i ,� � s3fS3CUR2J Ufc7L+R920R q :531s:3yXjfj = t3J53a:YJ2U 53 33fS3DUR6i+ 33/;i3UURfU y _ 33f53UURRU � 65ri0fi000fU 556U6UDUSi+ SW 314T}1 Lf+t U 27UR9733 U827UR925a �[',}fi5tiU6UC!U6�+ C,punt�U,`271R9737 Cti•ts�ti Parcel Number 0721049210 Site Address 31617 1 STAVE S Zip code 98003 RECEIVED Taxpayer FIRE DISTRICT #39 The information included on this map has been compiled by King County staff from a A U G 2 9 2012 variety of sources and is subject to change without notice. King County makes no representations or warranties, express or implied, as to accuracy, completeness, CITY ®F FEDERAL WAY timeliness, or rights to the use of such Information. King County shall not be liable for any general, special, indirect, incidental, or consequential damages including, but not limited CDS to, lost revenues or lost profits resulting from the use or misuse of the Information contained on this map. Any sale of this map or information on this map is prohibited +except�by written permission of King County." Parcel Number 0721049017 Parcel Number 0721049014 Site Address 31627 1ST AVE S Site Address Zip code 98003 Zip code LAKE HAVEN UTILITY Taxpayer LAKEHAVEN UTILITY DISTRICT Taxpayer DISTRICT Parcel Number 0721049198 Parcel Number 0721049204 Site Address Site Address 31620 3RD PL SW Zip code Zip code 98023 Taxpayer JONES JAMES NORMAN+TERRI AN Taxpayer SHORES AT FEDERAL WAY Parcel Number 0821049106 Parcel Number 3375300010 Site Address 31500 1 STAVE S Site Address 102 S 317TH PL Zip code 98003 Zip code 98003 Taxpayer GREYSTONE MEADOWS APTS Taxpayer COLLINS CALLEN R Parcel Number 3375300020 Parcel Number 3375300030 Site Address 110 S 317TH PL Site Address 31645 1ST PL S Zip code 98003 Zip code 98003 Taxpayer GLOVER BRI,')4 I Taxpa/—) MILLIMAN PHILIP C Parcel Number 3375300050 Parcel Number 3375300040 Site Address 31629 1ST PL S Site Address 31637 1 ST PL S Zip code 98003 Zip code 98003 ORCHARD TERRACE Taxpayer JURCA JIRINA Taxpayer ESTATES LLC Parcel Number 3375300060 Parcel Number 3375300070 Site Address 31621 1ST PL S Site Address 120 S 316TH PL Zip code 98003 Zip code 98003 Taxpayer DUNCAN RICHARD C Taxpayer PHAN TRANG PHUONG-THI Parcel Number 3375300080 Parcel Number 3375300710 Site Address 124 S 316TH PL Site Address Zip code 98003 Zip code Taxpayer WALLACE-BELT EARTHA+BELT IRAN Taxpayer FEDERAL WAY CITY OF CHARLES King County I GIS Center I News I Services I Comments I Search By visiting this and other King County web pages, you expressly agree to be bound by terms and conditions of the site. The details. Parcel Number '-) MetroScan /King (WA) Owner Name Site Address YB Owner Phone 072104 9014 072104 9017 072104 9017 072104 9017 072104 9198 072104 9204 082104 9106 337530 0010 337530 0020 337530 0030 337530 0040 337530 0050 337530 0060 337530 0070 337530 0080 337530 0710 Lakehaven Utility District Lake Haven Utility District Lake Haven Utility District Lake Haven Utility District Jones James Norman & Terri Ann Shores At Federal Way LLC Greystone Meadows LLC Collins Callen R/Sheila R Glover Brian A Milliman Philip C Jurca Jirina Canavan Daniel R/Mary L Duncan Richard C Phan Trang P;+ Belt Iran/Eartha City of Federal Way 31531 1 st Ave S Federal Way 98003 31627 1 st Ave S Federal Way 98003 31627 1 st Ave S Federal Way 98003 31627 1st Ave S Federal Way 98003 *no Site Address* Federal Way 31620 3rd P1 SW Federal Way 98023 31500 1st Ave S Federal Way 98003 102 S 317th P1 Federal Way 98003 110 S 317th P1 Federal Way 98003 31645 1st P1 S Federal Way 98003 31637 1st P1 S Federal Way 98003 31629 1st P1 S Federal Way 98003 31621 1st P1 S Federal Way 98003 120 S 316th P1 Federal Way 98003 124 S 316th P1 Federal Way 98003 *no Site Address* Federal Way 1985 1977 1981 1985 1987 1989 1985 1981 1981 1981 1981 1981 1986 1986 Information compiled from various sources. CoreLogic makes no representations or warranties as to the accuracy or completeness of information contained in this report. *------------------- - - - - -- MetroScan / King (WA) `^^ Owner :Lakehaven Utility Di: � ct Parc 0721049014 Site :31531 1st Ave S Federal Way 98003 Xfered :03/16/2000 Mail :PO Box 4249 Federal Way Wa 98063 Price Use :149 Rec,Parks,Zoos,Arboretum Phone Bedrm: Bath: TotRm: YB:1985 Pool: B1dgSF:2,160 Ac:4.68 *---------------------------- : MetroScan / King (WA) •----------------* Owner :Lake Haven Utility District Parcel :072104 9017 Site :31627 1st Ave S Federal Way 98003 Xfered Mail :PO Box 4249 Federal Way Wa 98063 Price Use :106 Off,Office Building Phone Bedrm: Bath: TotRm: YB:1977 Pool: B1dgSF:7,440 Ac:12.03 *---------------------------- : MetroScan / King (WA) ' •---�---------------* Owner :Lake Haven Utility District Parcel :072104 9017 Site :31627 1st Ave S Federal Way 98003 Xfered Mail :PO Box 4249 Federal Way Wa 98063 Price Use :106 Off,Office Building Phone Bedrm: Bath: TotRm: YB:1981 Pool: B1dgSF:15,000 Ac:12.03 *---------------------------- • MetroScan / King (WA) •----------------* Owner :Lake Haven Utility District Parcel :072104 9017 Site :31627 1st Ave S Federal Way 98003 Xfered Mail :PO Box 4249 Federal Way Wa 98063 Price Use :106 Off,Office Building Phone Bedrm: Bath: TotRm: YB:1985 Pool: B1dgSF:760 Ac:12.03 *---------------------------- • MetroScan / King (WA) •----------------* Owner :Jones James Norman & Terri Ann Parcel :072104 9198 Site :*no Site Address* Federal Way Xfered :10/26/1989 Mail :206 SW 316th St Federal Way Wa 98023 Price :$79,503 Use :008 Res,Mobile Home Phone Bedrm: Bath: TotRm: YB: Pool: B1dgSF: Ac:.56 *---------------------------- : MetroScan / King (WA) •----------------* Owner :Shores At Federal Way LLC Parcel :072104 9204 Site :31620 3rd Pl SW Federal Way 98023 Xfered :06/21/2007 Mail :9757 NE Juanita Dr #300 Kirkland Wa 98034 Price :$19,471,500 Use :020 Res,Condominium Phone Bedrm: Bath: TotRm: YB:1987 Pool: B1dgSF:80,850 Ac:9.49 *---------------------------- : MetroScan / King (WA) •----------------* Owner :Greystone Meadows LLC Parcel :082104 9106 Site :31500 1st Ave S Federal Way 98003 Xfered :05/17/2005 Mail :2800 Elliott Ave #A Seattle Wa 98121 Price Use :011 Res,Apartment Phone Bedrm: Bath: TotRm: YB:1989 Pool: B1dgSF:317,181 Ac:18.09 *---------------------------- : MetroScan / King (WA) •----------------* Owner :Collins Callen R/Sheila R Parcel :337530 0010 Site :102 S 317th P1 Federal Way 98003 Xfered :09/14/1992 Mail :102 S 317th Pl Federal Way Wa 98003 Price :$134,000 Full Use :002 Res,Single Family Residence Phone Bedrm:3 Bath:2.25 TotRm: YB:1985 Pool: B1dgSF:2,260 Ac:.26 *---------------------------- . MetroScan / King (WA) .-----------------* Owner :Glover Brian A Parcel :337530 0020 Site :110 S 317th Pl Federal Way 98003 Xfered :01/14/2008 Mail :110 S 317th Pl Federal Way Wa 98003 Price :$274,000 Use :002 Res,Single Family Residence Phone Bedrm:3 Bath:1.75 TotRm: YB:1981 Pool: B1dgSF:1,830 Ac:.22 *---------------------------- • MetroScan / King (WA) •----------------* Owner :Milliman Philip C Parcel :337530 0030 Site :31645 1st Pl S Federal Way 98003 Xfered :04/01/1982 Mail :31645 1st P1 S Federal Way Wa 98003 Price :$71,950 Use :002 Res,Single Family Residence Phone Bedrm:2 Bath:1.50 TotRm: YB:1981 Pool: B1dgSF:1,790 Ac:.20 *---------------------------- : MetroScan / King (WA) •----------------* Owner :Jurca Jirina Parcel :337530 0040 Site :31637 1st P1 S Federal Way 98003 Xfered :08/27/2004 Mail :31637 1st P1 S Federal Way Wa 98003 Price :$231,000 Use :002 Res,Single Family Residence Phone Bedrm:3 Bath:2.50 TotRm: YB:1981 Pool: B1dgSF:1,930 Ac:.19 Information compiled from various sources. CoreLogic makes no representations or warranties as to the accuracy or completeness of information contained in this report. *�----------------------------) MetroScan / King (WA) Owner :Canavan Daniel R/Mari Site :31629 1st P1 S Federal Way 98003 Mail :31629 1st P1 S Federal Way Wa 98003 Use :002 Res,Single Family Residence Bedrm:3 Bath:1.75 TotRm: YB:1981 Pool: * ---------------------------- . MetroScan / King (WA) Owner :Duncan Richard C Site :31621 1st P1 S Federal Way 98003 Mail :31621 1st P1 S Federal Way Wa 98003 Use :002 Res,Single Family Residence Bedrm:3 Bath:2.50 TotRm: YB:1981 Pool: *----------------------------: MetroScan / King (WA) Owner :Phan Trang P;+ Site :120 S 316th P1 Federal Way 98003 Mail :120 S 316th P1 Federal Way Wa 98003 Use :002 Res,Single Family Residence Bedrm:5 Bath:2.00 TotRm: YB:1986 Pool: *----------------------------: MetroScan / King (WA) Owner :Belt Iran/Eartha Site :124 S 316th P1 Federal Way 98003 Mail :124 S 316th P1 Federal Way Wa 98003 Use :002 Res,Single Family Residence Bedrm:3 Bath:2.50 TotRm: YB:1986 Pool: *----------------------------: MetroScan / King (WA) Owner :City of Federal Way Site :*no Site Address* Federal Way Mail :PO Box 9718 Federal Way Wa 98063 Use :300 Vacant,Residential Bedrm: Bath: TotRm: YB: Pool: ---------- - - - - - * Par( _ :337530 0050 Xfered :07/19/2012 Price :$165,000 Phone B1dgSF:1,830 Ac:.19 .----------------* Parcel :337530 0060 Xfered :07/22/1993 Price :$119,000 Full Phone B1dgSF:1,980 Ac:.20 . ---------------- Parcel :337530 0070 Xfered :06/21/2002 Price :$224,500 Phone B1dgSF:2,600 Ac:.26 .-----------------* Parcel :337530 0080 Xfered :07/21/2003 Price :$210,000 Phone B1dgSF:2,130 Ac:.18 •----------------* Parcel :337530 0710 Xfered :01/05/1993 Price Phone B1dgSF: Ac:1.45 Information compiled from various sources. CoreLogic makes no representations or warranties as to the accuracy or completeness of information contained in this report. Tamara Fix From: Tamara Fix Sent: Thursday, September 20, 2012 8:40 AM To: 'ECY RE SEPA UNIT' Cc. 'basbury@lakehaven.org'; Chris Ingham; Gordon Goodsell Subject: T-Mobile Mirror Lake NOA & Opt DNS Attachments: Tmobile Mirror Lk NOA + Opt DNS Pkt.pdf Attached are the NOA and Optional DNS and Annotated Environmental Checklist for the above T-Mobile project. This NOA & Opt DNS is being issued on September 20, 2012, by the City of Federal Way. The Assistant Planner for the project is Becky Chapin, rebecca.chapin cityofFederalway.com. Tamara J'ix Adi n.in .Ass t. City cif FederaCi4-a.y Camara. "xp atti o ederaC-wa .com "When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile." Unknown k 4ik CITY OF Federal Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8th Avenue South Federal Way WA 98003 253-835-7000; Fax 253-835-2609 www.cityo f f e de ra Iway.co m DECLARATION OF DISTRIBUTION 1, hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) Notice of Land Use Application & Optional DNS/MDNS ❑ FWRC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Public Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was ❑ mailed ❑ faxed M e-mailed and/or ❑ posted to or at each of the attached addresses on 2012. Project Name �� I r 1 o b� 1� M' r a k Q File Number(s) Signature. Date K:\CD Administration Res\Declaration of Distribution.doc/Last printed 1 /12/2012 2:20:00 PM CITY OF Federal Way NOTICE OF LAND USE APPLICATION AND NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: T-Mobile = SE04693 Mirror Lake Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Project Location: 31617 1" Avenue South, Federal Way Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012 Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012 Environmental Review: Based upon review of a completed environmental checklist and other information on file with the City, it is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to comment on the environmental impacts of the proposed project. The proposal may include mitigation measures under applicable codes, and the review process may incorporate or require mitigation measures regardless of whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for the specific proposal may be obtained upon request. Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable environmental impacts. Comments must be submitted by the date noted above. Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State Environmental Policy Act Threshold Determination (File # 12-104015-SE) Other Permits Known at this Time and Not Included in This Application: Electrical Permit Existing Environmental Documents: None Relevant Environmental Documents Are Available at the Address Below: Yes Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title 14, `Environmental Policy' and Title 19 `Zoning and Development Code.' Public Comment & Appeals: Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision_ Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of Nonsignificance may be obtained upon request. Availability of File: The official pgroject file is available for public review at the Department of Community and Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325. Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 Published in the Federal Way Mirror on September 21, 2012. Doc. I.D. 62208 \ .o _o �3 k 22aam § E2WZEcu a Cl)M 2 2 ' $�Kf{ `Oa°§ �@ owCL co @ Cc 2�MCM 2� �C � 0 2:em!ac LLfn 2a � m CoCU E 9 —0 g2ac=_ a) �me<kSO: a) IVO co � � 0 � .� 75 CY) CY) (D 191- C) w U) I a) DIW � � 2� §� � � -- (3 T CL / > ® 7." W CO 4 o 0 CD LO T- o C� C) C� oT--- L- Tamara Fix From: Mary Lou Goss <mgoss@fedwaymirror.com> Sent: Wednesday, September 19, 2012 11:56 AM To: Tamara Fix Subject: T-mobile legal Hi Tamara - Your T-mobile legal for Friday is all taken care off... Mary Lou Mary Lou Goss Federal Way Mirror Marketing Consultant cell - 253-229-3041 office - 253-925-5565 ext 3056 "In towns and cities where there is a strong sense of community, there is no more important institution than the local paper." Warren Buffett CIT Federal Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8th Avenue South PO Box 9718 Federal Way WA 98063-9718 253-835-7000; Fax 253-835-2609 www.cityoffederalway.com DECLARATION OF DISTRIBUTION 1, Kennith Georae hereby declare, under penalty of perjury of the laws of the State of Washington, that a: ❑ Notice of Land Use Application/Action ❑ Notice of Determination of Significance (DS) and Scoping Notice ❑ Notice of Environmental Determination of Nonsignificance (SEPA, DNS) ❑ Notice of Mitigated Environmental Determination of Nonsignificance (SEPA, MDNS) Notice of Land Use Application & Optional DNS/MDNS ❑ FWRC Interpretation ❑ Other ❑ Land Use Decision Letter ❑ Notice of Public Hearing before the Hearing Examiner ❑ Notice of Planning Commission Public Hearing ❑ Notice of LUTC/CC Public Hearing ❑ Notice of Application for Shoreline Management Permit ❑ Shoreline Management Permit ❑ Adoption of Existing Environmental Document was ❑ mailed ❑ faxed ❑ e-mailed and/or posted to or at each of the attached addresses on Se tember 190 2012. Project Name T-Mobile - SE04693 Mirror Lake File Number(s) Signature Date K:\Intern\Declaration of Distribution notices\Declaration of Distribution with Posting Sites.doc Posting Sites: Federal Way City Hall- 33325 &h Avenue Federal Way Regional Library- 34200 1st Way South FedeFel Way 20h, i ,a rwy 848 Se th 2`'iwL&#e-e4 Closed for Construction Subject Site- 31617 1st Avenue South K:\Intern\Declaration or Distribution notices\Declaration of Distribution with Posting Sites.doc . CITY of Federal Way NOTICE OF LAND USE APPLICATION AND NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS) Project Name: T-Mobile — SE04693 Mirror Lake Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included. Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007 Project Location: 31617 1" Avenue South, Federal Way Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012 Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012 Environmental Review: Based upon review of a completed environmental checklist and other information on file with the City, it is likely that the City of Federal Way will determine that the project will not have a probable significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to comment on the environmental impacts of the proposed project. The proposal may include mitigation measures under applicable codes, and the review process may incorporate or require mitigation measures regardless of whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for the specific proposal may be obtained upon request. Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable environmental impacts. Comments must be submitted by the date noted above. Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State Environmental Policy Act Threshold Determination (File 912-104015-SE) Other Permits Known at this Time and Not Included in This Application: Electrical Permit Existing Environmental Documents: None Relevant Environmental Documents Are Available at the Address Below: Yes Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title 14, `Environmental Policy' and Title 19 `Zoning and Development Code.' Public Comment & Appeals: Any person may submit written comments on the land use application or the environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental threshold determination. Details of appeal procedures for the requested land use decision will be included with the written decision. Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued without a second comment period, unless timely comments identify probable significant adverse impacts that were not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of Nonsignificance may be obtained upon request. Availability of File: The official project file is available for public review at the Department of Community and Economic Development, 33325 8"' Avenue South, Federal Way, WA 98003-6325. Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641 Published in the Federal Way Mirror on September 21, 2012. Doc. LD. 62208 N L rnf6 •X C U f6 Co LL m o U C C NHS � ow1 aEt° D(0 L� mac coQ�4� y o m " �oT, cf�� E L) CL N m 0 I to o. p �? C a)M (D � 'j v cr aa) ~ U) Q V m L a F• `� E 7 .0 C SL 3 U o f0 O C U- tow m (6 (� QS f6 '0 o .V C U _C a O Z o to s a)C CD U dU) l6Q C W cu O L C� C O CO CO O � C0 ,;I. Q O W U ~ 1 C.D M O 1 06 -J•�w lLN 4 O CD LO C, r- O m N O N N � 0 c, U- s ... . N S NI ONZ o �N J Cf) Qh _M U) M ' co M 7 I U) i ii- U ! FD Tcf) M U) 5 � Cf) J _ h N i 1 i CITY OF V:Zk� Federal Way September 20, 2012 Allison Zike RealCom Associates LLC 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www cityoffederalway. com RE: File #12-104014-00-UP; NOTICE OF COMPLETE APPLICATION T-Mobile — SE04693 Mirror Lake, 31617 0 Avenue South, Federal Way Dear Ms. Zike: On August 29, 2012, the City of Federal Way's Department of Community and Economic Development received your Process III Land Use application to modify the existing Personal Wireless Service Facility (PWSF) on a 150-foot monopole, by upgrading/replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9) antennas. The proposal also includes associated upgrades to the ground equipment within the existing fenced -in equipment shelter area. The Comprehensive Plan designation is Single -Family, High Density, and the zoning designation for the subject site is Single -Family Residential (RS9.6). Pursuant to the development application submittal requirements established in Federal Way Revised Code (FWRC) 19.65, the City has 28 days to determine whether your application is complete. NOTICE OF COMPLETE APPLICATION Please consider this letter as a Notice of Complete Application. Pursuant to the FWRC, the application is deemed complete as of August 29, 2012, based on a review of your submittal relative to those requirements as set out in the Development Requirements checklist. The submittal requirements are not intended to determine if an application conforms to the City of Federal Way codes; they are used only to determine if all required materials have been submitted. Having met the submittal requirements, a Notice of Application and Optional Environmental Determination of Nonsignificance (DNS) will be published in the Federal Way Mirror and posted at the subject property and on the City's official notice boards within 14 days of this letter. Notification will also be mailed to persons receiving property tax statements for property within 300 feet of the subject property. CLOSING A 120-day time line for reviewing the Process III application has started as of this date. The City has 120 days from the date that an application is deemed complete to take action on the application. However, the 120-day time line can be stopped at any time that the City requests additional information. You will be informed of the status of the 120-day time line when you are notified in writing that additional information is needed. If you have any questions regarding this letter or your development project, please contact me at 253-835-2641 or rebecca.chapin@cityoffederalway.com. Sincerely, BeckY Cha ri AAe�_— Assistant Planner enc: NOA/DNS Doc. LD. 62223 CITY OF FEDERAL WAY DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: September 4, 2012 TO: Ann Dower, Senior Engineering Plans Reviewer Rick Perez, City Traffic Engineer Scott Sproul, Plans Examiner Brian Asbury, Lakehaven Utility District Chris Ingham, South King Fire & Rescue FROM: Becky Chapin FOR DRC MTG. ON: Completeness Review - please email any comments. FILE NUMBER(s): 12-104014-00-UP, 12-104015-00-SE RELATED FILE NOS.: None PROJECT NAME: T-MOBILE - SE04693 MIRROR LAKE PROJECT ADDRESS: ZONING DISTRICT: 31617 1ST AVE S RS 9.6 PROJECT DESCRIPTION: Modify existing PWSF by upgrading/replacing six existing antennas and adding three new antennas. LAND USE PERMITS: Process III and SEPA PROJECT CONTACT: Allison Zike RealCom Associates 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 MATERIALS SUBMITTED; Master Land Use Application Project Description Vicinity Map Title Report (2) Photo Simulations (1) SEPA Checklist Site Plans 27 July 2012 City of Federal Way — Planning 33325 8th Ave. South Federal Way, WA 98003 Re: T-Mobile — SE0469A3 Mirror Lake — Proposed Modifications To Whom It May Concern: The intended upgrade of this cell site is required in order to prepare the site for the latest and the also the next generation of technology. The current antenna height will remain unchanged so that the existing coverage footprint (serving area of this site) is preserved. We do not want to adversely impact our customers by changing the antenna height. T-Mobile is currently modernising our Network to provide the latest technologies and enhanced voice and data services to our customers. This upgrade is required for T-Mobile to remain competitive in the rapidly evolving world of wireless voice and data services. In order to be able to support the additional technologies, the site upgrade will require the addition of three (3) antennas to the existing six (6) antennas for a total of nine (9) antennas on the site. This will facilitate the deployment of GSM 1900, UMTS 1900 and UMTS 2100 as well as LTE. I have attached a map showing this site and the surrounding sites in the area for your reference I trust that this information is helpful in your review of the proposed site modification / upgrade. Thanking you in advance. Darryl Salk Seattle RF Engineering, Site Deployment -T- m -Mobile, USA 19807 North Creek Parkway N Bothell, VVA, 98011 PNW000 DECEIVED AUG 292012 CITY OF FEDERAL WAY CDS T Area map showing T-Mobile On Air Sites a a S 2 1 St SE SE04692H h SE040221 SE040361 SE04653A SE04693A N SW 320th St S 320eh Sr Q SE04014C SE04661A SW 336th St � C SE04754E NE SE04799A S E04753A SE055814 A y 9 z N z SE04 First American Title (WA) Commitment 1 A u . , First American Title Insurance Company 01 ' First American 818 Stewart St, Ste 800 Seattle, WA 98101 Phn - (206)728-0400 (800)826-7718 Fax - King County Title Team Two 818 Stewart St, Ste. 800, Seattle, WA 98101 Fax No. (866) 561-3729 LaVonne Bowman Kelly Cornwall Curtis Goodman (206)336-0728 (206)336-0725 (206)615-3069 lavbowman@firstam.com kcornwall@firstam.com cgoodman@firstam.com Peter Child Kathy Turner (206)336-0726 (206)336-0724 pchikl@firstam.com kturner@firstam.com PLEASE SEND ALL RECORDING PACKAGES TO 818 STEINART ST, STE. 800, SEATTLE, WA 98101. To: RealCom Associates 14432 SE Eastgate WAY STE 260 Bellevue, WA 98007 Attn: Sarah Telschow File No.: 4209-1944841 Your Ref No.: T-Mobile - SE04693 Mirror Lake Re: Property Address: 31617 1st Avenue South, Federal Way, WA 98003 COMMITMENT FOR TITLE INSURANCE Issued by FIRST AMERICAN TITLE INSURANCE COMPANY Agreement to Issue Policy We agree to issue a policy to you according to the terms of this Commitment. When we show the policy amount and your name as the proposed insured in Schedule A, this Commitment becomes effective as of the Commitment Date shown in Schedule A. If the Requirements shown in this Commitment have not been met within six months after the Commitment Date, our obligation under this Commitment will end. Also, our obligation under this Commitment will end when the Policy is issued and then our obligation to you will be under the Policy. Our obligation under this Commitment is limited by the following: The Provisions in Schedule A. The Requirements in Schedule B-I. The General Exceptions and Exceptions in Schedule B-II. The Conditions. This Commitment is not valid without Schedule A and Section I and II of Schedule B. RECEIVE® AUG 292012 FirstAmerican Title First American Title r.nq First American Title Form No. 1068-2 ALTA Plain Language Commitment FirstAmerican rtie Insarance Company 1 A3CG� Curtis Goodman, Title Officer RrstAmedcan Tide First American Title Commitment No.: 4209-1944841 Page 2 of 10 First American Title Form No. 1068-2 commitment No.: 4209-1944841 ALTA Plain language Commihnent Page 3 of 10 SCHEDULEA 1. Commitment Date: August 14, 2012 at 7:30 A.M. 2. Policy or Policies to be issued: AMOUNT PREMIUM TAX General Schedule Rate ALTA Standard Owner's Policy $ To Follow $ To Follow $ To Follow Proposed Insured: To Follow Work Charge $ 450.00 $ 42.75 3. (A) The estate or interest in the land described in this Commitment is: Fee simple as to Parcel(s) A, an easement as to Parcel(s) B. (B) Title to said estate or interest at the date hereof is vested in: King County Fire District No. 39 4. The land referred to in this Commitment is described as follows: Real property in the County of -King, State of Washington, described as follows: The land referred to in this report is described in Exhibit A attached hereto. RmtAmerican Tithe First American Title First American Title Form No. 1068-2 ALTA Plain Language Commitment SCHEDULE B SECTION I REQUIREMENTS Commitment No.: 4209-1944841 Page 4 of 10 The following requirements must be met: (A) Pay the agreed amounts for the interest in the land and/or the mortgage to be insured. (B) Pay us the premiums, fees and charges for the policy. (C) Documents satisfactory to us creating the interest in the land and/or the mortgage to be insured must be signed, delivered and recorded: (D) You must tell us in writing the name of anyone not referred to in this Commitment who will get an interest in the land or who will make a loan on the land. We may then make additional requirements or exceptions. (E) Releases(s) or Reconveyance(s) of Item(s): (F) Other: (G) You must give us the following information: 1. Any off record leases, surveys, etc. 2. Statement(s) of Identity, all parties. 3. Other: SCHEDULE SECTION II GENERAL EXCEPTIONS PART ONE: A. Taxes or assessments which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the public records. B. Any facts, rights, interests, or claims which are not shown by the public records but which could be ascertained by an inspection of said land or by making inquiry of persons in possession thereof. C. Easements, claims of easement or encumbrances which are not shown by the public records. D. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other facts which a correct survey would disclose, and which are not shown by the public records. E. (A) Unpatented mining claims; (B) Reservations or exceptions in patents or in Acts authorizing the issuance thereof; (C) Water rights, claims or title to water; whether or not the matters excepted under (A), (B) or (C) are shown by the public records; (D) Indian Tribal Codes or Regulations, Indian Treaty or Aboriginal Rights, including easements or equitable servitudes. F. Any lien, or right to a lien, for services, labor or materials or medical assistance heretofore or hereafter furnished, imposed by law and not shown by the public records. G. Any service, installation, connection, maintenance, construction, tap or reimbursement charges/costs for sewer, water, garbage or electricity. H. Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof, but prior to the date the proposed insured acquires of record for value the escrow or interest or mortgage(s) thereon covered by this Commitment. FiistAmedcan Title First American Title First American Title Form No. 1068-2 ALTA Plain language Commitment SCHEDULE B SECTION II EXCEPTIONS PART TWO: Commitment No.: 4209-1944841 Page 5 of 10 Any policy we issue will have the following exceptions unless they are taken care of to our satisfaction. The printed exceptions and exclusions from the coverage of the policy or policies are available from the office which issued this Commitment. Copies of the policy forms should be read. 1. Lien of the Real Estate Excise Sales Tax and Surcharge upon any sale of said premises, if unpaid. As of the date herein, the excise tax rate for the City of Federal Way is at 1.78%. Levy/Area Code: 1205 2. The property herein described is carried on the tax rolls as exempt; however, it will become taxable from the date of transfer to a taxable entity. Tax Account Number: 072104-9210-01 3. Lease and the terms and conditions thereof as disclosed by Memorandum of Lease. Lessor: King County Fire District No. 39 and Lakehaven Utility District, as Tenants in Common Lessee: Interstate Mobilephone Company, a Washington General Partnership, dba AT & T Wireless Services Term: 10 years Dated: November 27, 1995 Recorded: November 29, 1995 Recording Information: 9511291210 Said Lease, among other things, provides for an option to renew. For a period of: 4 subsequent of optional extension terms of 5 years each 4. Lease and the terms and conditions thereof as disclosed by Memorandum of Lease. Lessor: King County Fire District No. 39 Lessee: GTE Wireless of the Pacific Incorporated Term: 5 years Dated: July 05, 2000 Recorded: August 11, 2000 Recording Information: 20000811000020 Said Lease, among other things, provides for an option to renew. For a period of: five (5) additional terms of five (5) years each 5. Unrecorded leaseholds, if any, rights of vendors and security agreement on personal property and rights of tenants, and secured parties to remove trade fixtures at the expiration of the term. 6. Right to make necessary slopes for cuts or fills upon said premises for 1st Avenue South as granted by deed recorded under recording no. 5331649. FirstAmerican Title First American Title First American Title Form No. 1068-2 ALTA Plain Language Commitment Commitment No.: 4209-1944841 Page 6 of 10 7. Easement, including terms and provisions contained therein: Recorded: July 07, 1977 Recording Information: 7707070719 In Favor Of: Puget Sound Power & Light Company, a Washington corporation For: Electric transmission and/or distribution system 8. Easement, including terms and provisions contained therein: Recording Information: July 19, 1978 under Recording No. 7807190971 In Favor of: Lakehaven Sewer District, a Municipal Corporation For: Sewer mains with the necessary appurtenances Affects: The West 10 feet of the East 92 feet of the North 275 feet of said premises 9. Drainage Release and the terms and conditions thereof: Between: Stanley P. Johnson and Irene R. Johnson And: King County Recording Information: January 20, 1983 as Recording No. 8301200660 10. Easement, including terms and provisions contained therein: Recording Information: October 22, 1996 under Recording No. 9610221522 For: Ingress and Egress 11. Easement, including terms and provisions contained therein: Recording Information: October 22, 1996 under Recording No. 9610221523 In Favor of: Lakehaven Utility District, a Municipal Corporation For: Water Facilites Affects: The Southerly portion 12. Terms, covenants, conditions and restrictions as contained in recorded Lot Line Adjustment (Boundary Line Revisions): Recorded: October 28, 1996 Recording Information: 9610289005 13. Covenants, conditions, restrictions and/or easements: Recorded: November 15, 1996 Recording No.: 9611151827 14. Easement Agreement and the terms and conditions thereof: Between: King County Fire District No. 39 And: GTE Wireless of the Pacific Incorporated, a corporation Recording Information: August 11, 2000 as Recording No. 20000811000021 FirstAmerican Title First American Title First American Title Form No. 1068-2 ALTA Plain Language Commitment INFORMATIONAL NOTES Commitment No.: 4209-1944841 Page 7 of 10 A. Potential charges, for the King County Sewage Treatment Capacity Charge, as authorized under RCW 35.58 and King County Code 28.84.050. Said charges could apply for any property that connected to the King County Sewer Service area on or after February 1, 1990. Note: Properties located in Snohomish County may be subject to the King County Sewage Treatment Capacity Charges. B. Effective January 1, 1997, and pursuant to amendment of Washington State Statutes relating to standardization of recorded documents, the following format and content requirements must be met. Failure to comply may result in rejection of the document by the recorder. C. Any sketch attached hereto is done so as a courtesy only and is not part of any title commitment or policy. It is furnished solely for the purpose of assisting in locating the premises and First American expressly disclaims any liability which may result from reliance made upon it. D. The description can be abbreviated as suggested below if necessary to meet standardization requirements. The full text of the description must appear in the document(s) to be insured. LOT B, CITY OF FEDERAL WAY BLA-95-0011, REC. 9610289005, KING COUNTY APN: 072104921001 5. Special taxes for the year 2012, which have been paid. Tax Account No.: 072104921001 Code Area: 1205 Amount: $ 1,922.92 Assessed Land Value: $ 0.00 Assessed Improvement Value: $ 0.00 F. The following deeds affecting the property herein described have been recorded within 36 months of the effective date of this commitment: NONE G. Name and address of current taxpayer according to the King County Assessors record are: Fire District #39 31617 1st Ave S Federal Way, WA 98003 H. The vestee(s) herein acquired title by instrument(s) recorded under Recording Number(s) 9611151827. Property Address: 31617 1st Avenue South, Federal Way, WA 98003 NOTE: The forthcoming Mortgagee's Policy will be the ALTA 2006 Policy unless otherwise noted on Schedule A herein. NOTE: We find no judgments or Federal tax liens against the vestee herein, unless otherwise shown as a numbered exception above. First Ainer%Can Title First American Title First American Title Form No.1068-2 ALTA Plain Language Commitment CONDITIONS Commitment No.: 4209-1944841 Page 8 of 10 1. DEFINITIONS (a)"Mortgage" means mortgage, deed of trust or other security instrument. (b)"Public Records" means title records that give constructive notice of matters affecting the title according to the state law where the land is located. 2. LATER DEFECTS The Exceptions in Schedule B - Section II may be amended to show any defects, liens or encumbrances that appear for the first time in the public records or are created or attached between the Commitment Date and the date on which all of the Requirements (a) and (c) of Schedule B - Section I are met. We shall have no liability to you because of this amendment. 3. EXISTING DEFECTS If any defects, liens or encumbrances existing at Commitment Date are not shown in Schedule B, we may amend Schedule B to show them. If we do amend Schedule B to show these defects, liens or encumbrances, we shall be liable to you according to Paragraph 4 below unless you knew of this information and did not tell us about it in writing. 4. LIMITATION OF OUR LIABILITY Our only obligation is to issue to you the Policy referred to in this Commitment, when you have met its Requirements. If we have any liability to you for any loss you incur because of an error in this Commitment, our liability will be limited to your actual loss caused by your relying on this Commitment when you acted in good faith to: comply with the Requirements shown in Schedule B - Section I or eliminate with our written consent any Exceptions shown in Schedule B - Section II. We shall not be liable for more than the Policy Amount shown in Schedule A of this Commitment and our liability is subject to the terms of the Policy form to be issued to you. 5. CLAIMS MUST BE BASED ON THIS COMMITMENT Any claim, whether or not based on negligence, which you may have against us concerning the title to the land must be based on this commitment and is subject to its terms, cc: cc: Lakehaven Utility FirstAmerican Title First American Title First American Title Form No. 1068-2 Commitment No.: 4209-1944841 ALTA Plain Language Commitment Page 9 of 10 FirstAmencan Title Insurance Company ¢ First American 818 Stewart St, Ste 800 Seattle, WA 98101 Phn - (206)728-0400 (800)826-7718 Fax - :�►► I FirstAmericen Title prrvaq rnf.rm.tWh We Are Commdt.d to Salegumd rig Customer Informatlan In order to oeger serve your nerds mar and in the Nara vie may ask you to provide m with certain Information. We unde iteid that you may be caocemed abort idiot we will do with such info-Mckin - parreu" erhy personal or h(Wdal kdmnatm. We agroe that you name a right W knoyr haw we will utilize the personal Informoum you pmvide In us. Therecre, tooef her with our wbstdarhs we have adopW this Privacy Poky W govern the use and handing of your Pefaonal nfamaWn. Rppilubaity This Privxy Pally govems our use of the Information that you provide to us. It does not govem die manner In which we may use Information we bare obtained from any other source, Muth as information ootmned from a public record or from another person or entity. First Mho ican has aho adopted broader guidelines that govem our use of persuul information regardless of its sowce. First American calls these guidelines its Fair Information Values. Typal of Infnrmad.n Dep, dvig rpm which er ow Merrier you are utkmg, the types of nonpublic personal Infamhauen that we may colle-t wclude: • Infmrnatlm receive rece tram you on appialnns, farms and in other WmrmuokNlms to us, whether In wrtrnl, In person, by telephone or any other means; • Information about your transactions with us, our affiliated companies, or others; and • Information we receive from a consumer reporting agency. Use of Information We request Information from you for our own legdk ut busncs purposes and not for the benefit of any nonafRbated parry. Therefore, snit wal not rckate ysxrr wfmmaimn to nanaffhhatmt parties eecept: (I) as necessary for m lu p"Kilde the Nu*a a service you have nequeited arm; m (2) os permitted M law. We My, however, star such Hformat4on Yhdnnitely, tulodchg the prrioe alter which arty customer n¢Hienrihlp has erased. Such Wommatbn may be used for airy Internal propose, suds as ghraNty [cnbd efforl1 a rrustomc arma}ysb. Svc may akn provxk all cur the type ad nonpublic ftasmhd INamatlan Reed above to one a mom of our afniuted companies. timers NNueyd emhpanfes eM[IhAa fnarheul shyvloe prcnidas, wan as trio hrN rrers, propesry oM asuaiy ►rwrers, and IruH i[hd fnmmhrra advvsory eoaepauks, a edrrpannfes NnrWvod >n rh>as hxtak adW[es, wan ors apPrddal [ompanLa, imenx wararhty [onhpanks and ei[foMr [wnpantes. fu111KYmhae, we may abo provide all the tfhfwmatred we muesli m desvbed abara, to vompanies fret pehfpfm maeh .ltethag services on our behalf, on balf of man alfi4ded ionVianks W to othher frham w Institutims with whom we or our affiliated companies have joint marketing agreements. Former Customers Even if you are no longer our customer, our Privacy Policy will continue to apply to you. Confidentiality and Security We will use our best efforts to ensure that no unauthorized parties have access to any of your Information. We restrict access to nit putik pe o-A hdmoatloa about you to those individuah and entities who need to know that information to provide products or services to you. We will use our best efforts to train and oversee our employees and agCdS to f>"ima that your Information will be handled responsibly and in accordance with this Privacy Policy and First American's Fair Information Values. We currently maintait physkA rdectrenk, and procedural saf4ghards dial compk with federal regulations to guard your nonpublic personal information. Information Obtained Through Our Web Site First American Financial Corporation is sensitive to privacy Issues on the Internet. We believe it is important you know how we treat the information about you we receive on the Internet. In general, you can visit First American or its affiliates' Web sites on the World Wide Web without telling us who you are or revealing any Information about yourself. Our Web servers collect the domain names, not the e-mail addresses, of visitors. This information Is aggregated to measure the number of visits, average time spent on the site, pages viewed and similar Information. First American uses this Information to measure the use of our site and to develop Ideas to improve the content of our site. There are times, however, when we may need Information from you, such as your name and emall address. When Information is needed, we will use our best efforts to let you know at the time of collection how we will use the pesonal information. Usuatly, the perswhaf information we collect is used only by us to respond to your Inquiry, process an order or allow you to access specific accountlprofile information. tryou (house to share My Personal Infomytlon wkh as, we will only use it in accordance with the policies outlined above. Businass BalatdanaTnlps First Amerimn Fihaadal Corporation's site and Rs afBhdreY sites may contain inks to other Web sites. While we try to link only to sites that share our high standards and respect for privacy, we are not re4mrrs4le for the content or the privacy podicts employed by other sues. Cookies Some of First American's Web sites may make use of "cookie" technology to measure site activity and to customize information to your personal tastes. A cookie is an element of data that a Web site ,an send to yma bmwsa, which may then store the aotkk on your hod drive. F Cut aldtff0 uses stored cockles. The pool of ads teAmology Is to bow serve you when visiting our she, save you time when you are here and to provide you with a more meaningful and productive Web site experience. Fab Information Values Fairness We consider consumer expectations about their privacy in all our businesses. We only offer products and services that assure a favorable balance between consumer benefits and consumer Publ a Roenrd We bearve that w ghee publk record oeates Syrlfirant value for society, eNNnbx Wnfu<hw Chace and creates ewe . vf+paturhiry We agM* Support an open Pub1k record and dnphasae ks lmportan[e and contribution W cur a conamy. Uses We believe we should behave vespo ul, when we use nhxrrwlton ahaut a oomumer m cur busydo . We wdl obey the ions gavem✓sB the collection. use amp deseminatan of data. Aiculaey We wa tole rmwiatk sills W hey assure the occun icy of are data we colkcy use and disc minad. Where pmsnle, we will take reasonable ceps to correct inaccurate information. When. m with the pubs record, we Cannot correct lnacm,,Mt infmnatka, we will take all mmonabk Sups W assht mrounim in Ideril"j; rime soiree or the erroneous data se that vie cwamox run secure the required corrections. educwdoh We endeahmr to educate the user of our pradult, and serOm, au emplpyeef area ntkss A cur kAntry. abaft the Import" of canwnw prvacy. We Will Instruct our emmptoyecr on dtm fall Information values and on the respons4hk [oienim and use of dahl. We call bm[uuiyb OS}Ipf lA err tmdl4aY W Chian add use nformaw n a rnpomble manner. Security We wor maintain apprcryWte fad6tks cord systfms W protect against IumaathRiTld aPc�a w.attd Witt Uyatf the dam we miauiaam. Form 50-PRIVACY (8/1/09) Page 1 of 1 Privacy Information (2001-2010 First American Financial Corporation) FirstAmerican Title First American Title First American Title Form No. 1068-2 Commitment No.: 4209-1944841 ALTA Plain Language Commitment Page 10 of 10 FIRSTAMERICAN TITLEINSURANCE COMPANY Exhibit "A" Vested Owner: King County Fire District No. 39 Real property in the County of King, State of Washington, described as follows: PARCEL A: LOT B OF CITY OF FEDERAL WAY BOUNDARY LINE ADJUSTMENT NO. BLA-95-0011 RECORDED OCTOBER 28, 1996 UNDER RECORDING NO. 9610289005 IN KING COUNTY, WASHINGTON. PARCEL B: A NON-EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS AS ESTABLISHED IN RECORDED OCTOBER 22, 1996 UNDER RECORDING NO. 9610221522, IN KING COUNTY, WASHINGTON. EXCEPT ANY PORTION WITHIN PARCEL A ABOVE. Tax Parcel Number: 072104921001 Situs Address: 31617 1st Avenue South, Federal Way, WA 98003 FirstAmerlcan Title First American Title First American Title 2. Map -Customer Dot .0 V6 'I s.Lb4 "a i;row nnno 2A .UWIQ ON n� 's �7•Rl[I 75: 9C-f0-1 R psi � 9F-rA-Ip H - - •• _ First American Title RECEIVE SE04693A MIRROR LAKE- „ =a NRSIMNE CINGULAR- KC FIRE p,Uri 4E0 �2011 Get EXISTING SOUTH ELEVATION • Mobile - more from life CITY OF F1gD� ERAL WAY CDJ 'r4; - CL .. +r ---+ i-�-i SE04693A MIRROR LAKE- T R .Mobile ■- m FgFINERSlro9VE CINGULAR- KC FIRE EXISTING EAST ELEVATION Get more from life SE04693A MIRROR LAKE- �_ o �o�r�e�s�rorve CINGULAR- KC FIRE PROPOSED EAST ELEVATION :dry -Mobile- Get more from iife PROJECT DESCRIPTION INTRODUCTION T-Mobile is a wireless telephone company operating throughout the United States of America. T- Mobile is licensed to operate in the United States by the Federal Communications Commission (FCC). T-Mobile is currently expanding its network in the King County area to make available improved telephone service and provide wireless capacity to its subscribers. This proposal describes the scope of the proposed project by providing specific information regarding the project location, zoning, specifications, and required services. It is T-Mobile's desire to work with the City of Federal Way to ensure that this project is consistent with local ordinances and zoning regulations while providing wireless coverage to T-Mobile's customers and provide critical communication services for emergency, business, and personal use. Project Goals The goal of the T-Mobile SE04693 Mirror Lake Site is to upgrade T-Mobile's existing network to provide better telephone service. T-Mobile intends to achieve these network goals consistent with all policies and ordinances of the City of Federal Way. Application Request Plan The applicant is requesting the following: ■ Process III Land -Use Review * SEPA Review IN Commercial Building Permit T-Mobile SL0,1693 Mug or Like Page t RECEIVED AUG 292012 CITY OF FEDERAL WAY CDS GENERAL PROJECT DESCRIPTION Project Overview The applicant, T-Mobile, proposes to modify an existing telecommunication facility located at 31617 1st Ave South (Parcel No. 0721049210) to provide expanded services. The proposed modification consists of the following: Upgrade/replace six (6) existing antennas and add three (3) new antennas. Please see Sheet. A-1.2 and A-2 for additional information. Facility Specifications ■ Antennas - T-Mobile is proposing to upgrade/replace six (6) existing antennas and add three (3) new antennas. Please see Sheet A-1.2 and A-2 for additional information. ■ Color - The antennas and associated mounting hardware will be painted to match the existing site conditions. ■ Facility Maintenance - The facility is generally serviced once a month. One (1) to two (2) employees are on site for an average of four (4) hours of maintenance checks. This check is typically for preventive maintenance purposes. In the event of a problem, a crew is dispatched to the site immediately. ■ I. uidsca )in r Scrceiiin - No changes are proposed to the existing on -site screening. GENERAL SITE ANALYSIS Zoning General Plan Designation The property is zoned RS-9.6. According to the Federal Way Revised Code (FWRC) 19.200.190 the proposed modification would require the review and approval of a Process III Land Use Review, SEPA Review, and Commercial Building Permit: The follwAring uses shall be permitted in the single-fiunily residential (RS) zone subject to the regulations and notes set forth in this section: T-Mobile SAVAiMlY Miii or Lake Page 2 USE ZONE CHART DIR EC TIONS: FIR ST, read doifmto find u:se . . TH EN, across for R EGULATIONS Nini mu ms 70-,F. `lards Required Required q Maxi n-ru rn Required Us � { USE REGULATIONSSide Review Lot Height Lands_ape Signs Parking Process Size IFrcnt Spaces �e - SPECIAL . .Rear led h. REGU LAT IONS d AND NOTES PersonaImire less Process See See See See Refer to Seenote 2 Not NIA 1.Not :service faeilibj II note note note 1 note FUURC allokned applicable. (PUUSF) 1 1 1 19.255,020 on a Puri S'Fs allovtled See note 3 for for IPUUSF on existing allowed bjpes of maximum structures only. PUUS Fs heights for 2. All PUU S Fs allowed shall be types of landscaped and P'uUSFs sore ened in accordance with Chapter 19.125 FUURC and the p rovis in ns of the Puri SF development regulations. At a minimum, a five ft. type III landscaping area shall be required around the fa cility, unless the community development services director determines that the facility is adequately screened 3. N ew freestanding PUUSFs are not allowed. P'uUSFsshall be a lowed only on existing towers, 'on publicly used structure= not located in public on structures 1�} ca W_ d in the T-Mobile SE0,16,93 Minor Lake Page 3 BPAtrail, an, or exis ti ng structures in appropriate public rights - of -way. Refe to FWRC 19.255.02D 1 development standards applicable to alowedtype of PtiAlSFs. For other information about parkin and parking Process I, II, III and fV are described in dfeaS,s ee Chapter 1955 FWRC, Chapter 19-1 LQ Chapter 19.BO F'OVRC, FWRC Chapter 19.B5 FVYRC, For details o Chapter 19.70 FWRC respectivety. what may exceed this height limit,s ae FWRC 19.1101D50 seq. For details regarding required yar see FWRC 19.125.160 seq. (Ord. No.09.6v3. § 12. 11-17-09: Ord- No.00-3363,§ 4. 1-400; Ord No. 97.300,§ 3, 9.16.97. Code2001 § 22-649.) 'Cross rderences: Parking commercial vehicles in R S districts, FUURC S50.020; legislative rezoning procedure applicable to this district, FWRC 19.35.040; supplementary district regulations, FWRC Title 19, DivisionViI. Accordingly, T-Mobile is requesting the review and approval of a Process III Land Use Review, SEPA Review, and Commercial Building Permit. Development Standards According to the FWRC 19.255.020: The follorrirrg development stuAuds shall he follm ed in the design, siting; uld comouctioli ofz personal rflir-eless sei-race facility.• (1) Building- or so-uctur-e-rlloullted PWSFs orl el7strng hurldrngs or- souctui-es in or- out of the public right-of-vrwy. PWSFs mounted on evstilig huildiigs vnd structures shall conform to the follorringdeveloprniaw stvldards: (q) The PWSFsljdl consist wily o1-tlle follorTirng types off7cdities: (i) A rllrcl-ocell or -a mjrior Acrllty7 or (rr) A PWSF that exceeds the minor facility thresholds for- mmnbel- of aliterilias, dimernsrorls, xidlor- area, but creates rlo mole adverse impacts drvi a minor facility; as deteiuriried by the director of- conlmunity development sei-races, suhicct to meeting- all of- the 10116 rririg st vid u ds: (A) The facility shill not cl-ezte suhstmli dly more adivisc raswd impact thin z lilrrlol-ficrlrty; vnd T-Mobile SE04693 Mirror- I Ike Page 4 (B) The equipment cabinet for the PWSF shall meet all regeurcineuts of subsection (f) of this section; vid (C) The inaxiinmn size of the PWSF pviels vid number of• viteiitias sh d] be determined by the diiector of conunuinty development services, based on the specific project location, sm7oundmgemironnient, audpolenfid vosualimpacts; vid (D) The PWSF shall comply with dll other applicable stimdai ds of the Federal Wty, Re rased Code. (b) The combined uiterinas grid supporti ig-structure may erlend up to, but not erceed, 15 feet above the existing or proposed roof or other structure regardless of whether the existing stiuclure is in confoiirivicc u th the existing in2rrmurn height of the underlying zone as outlined iri the use zone chits, FWRC Tide 19, Division W,, Zoning Regulations. Auterinas may be mounted to rooFop appuitenvices, as identified in FWRC 1.9.110.070, provaded they do not extend beyond 15feet above the maximum height of the structure as defined per FWRC 1-9.OS. 080, H definitions... T-Mobile's proposed modifications will not create additional adverse impacts. Screening Standards According to the FWRC 19.255.020(3): Screening standards for all PWSF.". PWSFs shall be screened or (mloull:�,ml through employing (lie best available technolov acid desibm, as ddertnined by the city. `!'Iris may be accomplished by use of' compatible materials, location, landscaping, color, stealth techniques such as, but not limited to, artificial tines and hollow flag poles, and/or other methods or techniques to achieve minimum visibility of the facility as viewed from public streets or residential properties. In addition, the provisions for landscaping as outlined in the use zone charts, FWRC Title 19, Division VI, Zoning Regulations, shall apply. The new antennas will be painted to match the existing tower. Standards for Flectronic Cabinets According to the FWRC 19.255.020(4): Standards for electronic cabinets. (a) Electronic cabinets shall either: (i) Be placed in a new or existing completely enclosed building. It is the applicant's responsibility to prove that the maximum size of tine building is the minimum size necessary to house the equipment; or (ii) Be placed above ground in a new or existing equipment enclosure. It is the applicant's responsibility to prove that the maximum size of the building is tine minimum size necessary to house tine equipment. (b) Equipment enclosures shall be screened With one or a combination of the following methods, which shall be acceptable to the city: fencing, walls, landscaping, structures, buildings or topography which will block the view of the equipment enclosure to the greatest extent possible from any street and/or adjacent properties, as determined by the director of community development services. Screening may be located anywhere between the enclosure and tine above -mentioned viewpoints. T-Mobile SE046.93 Mirror L7A-c Page 5 I andscaping for the purposes of screening sliall be m<unt<uned in a healthy condition, pursuant to F\VRC 19.125.090(2). - (c) If the equipment cabinet is located iaithin a new enclosed building, the building shall conform to all applicable development standards mid design guidelines for the underlying zone. The enclosed building shall be achitecturally designed mid sli<all be compatible Nvith existing buildings on the site. The enclosed buildnig sliall be screened to the greatest extent possible from any street mid/or adjacent properties by landscaping and/or topography. T-Mobile is not proposing any changes to the equipment cabinets and/or the enclosure. Standards for Equipment Enclosures According to the PWRC 19.255.020(5): Standards for equipment enclosures. (a) Electronic equipment enclosures sliall not be allowed within the night-of- Avay. (b) In residential zones, equipment enclosures located above ground on properties adjacent to the public right-of-way shall meet all applicable setback requirements for residential development of the Underlying zone. For developed sites in nonresidential zones, the setback requirements for the equipment enclosure shall be those of the principal use of the subject property. For undeveloped sites in nonresidential zones, the setback requirements for the equipment enclosure shall be 20 feet for front, side, and rear yards. However, for undeveloped sites in nonresidential zones, if the applicant can demonstrate that the equipment enclosure car blend in harmoniously with the existing site and complement the landscape buffer requirements of the underlying zone, as determined appropriate by the director of community development services, the equipment enclosure can be located inside of the 20-fool setback but outside of the required landscaping buffer of the underlying zone. (c) Equipment enclosures shall be designed, located, and screened to minimize adverse visual impacts from the public right-of-way and adjacent properties. (d) Equipment enclosures shall be designed, located, and screened to minimize adverse visual and functional impacts on the pedestrian environment. (e) Equipment enclosures and screening shall not adversely impact vehicular sight distance. T-Mobile is not proposing any changes to the equipment cabinets and/or the enclosure. T-Mobile SIs01693Mj�iorL ke Page 6 Security Fencing According to the FWRC 19.255.020(6): Security fencing. (a) No fence sliall exceed six feet in height as stipulated in FWRC 19.12.5.160(5). (b) Security fencing sliall be effectively screened from view through the use of appropriate landscapuig materials. (c) Chain -link fences shall be painted or coated with a nonreflective color. T-Mobile is not proposing any changes to the equipment cabinets, the enclosure, and/or the fencing. Existing Use The subject area accommodates existing telecommunication facilities. Access/Circulation The site will be accessed by the existing right of entry. There are no traffic impacts associated with these types of facilities as they are unmanned and require infrequent maintenance. FCC Time Period Guidelines On November 18, 2009, the FCC issued a Declaratory Ruling (FCC-09-99A1) that created periods of time under the Telecommunications Act (TCA) in which zoning authorities must act upon siting applications filed by wireless carriers or be in violation of the TCA. Specifically, the timelines are as follows: ninety (90) days for co -locations and one hundred fifty (150) days for all other sites including new towers. Please see the FCC Declaratory Ruling 09-99A1 for more detailed information. Federal Requirements T-Mobile's telecommunication facility will meet or exceed current standards and regulations of the FAA, the FCC, and any other agency of the Federal government with the authority to regulate towers and antennas. T-Mobile's site will conform to all FAA/FCC regulations, and because the maximum ERP is less than two thousand (2,000) watts and/or the height of the facility is greater than ten meters (10m), an environmental evaluation of radio frequency emissions is exempted per CFR Title 47 Part 24, Subpart E. T-Mobile has a license from the FCC to provide wireless telecommunication services throughout Washington State. T-Mobilc SE04693 Mirror Lake Page 7 41k CITY OF 40'::tt�:P Federal Way DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8`h Avenue South Federal Way, WA 98003-6325 253-835-2607;Fax 253-835-2609 w w w. e i t yo f federal way. cow ENVIRONMENTAL a�� C�ir1 j NAY CHECKLIST PURPOSE OF CHECKLIST The State Environmental Policy Act (SEPA), Revised Code of Washington (RCW) Chapter 43.21C, requires all governmental agencies to consider the environmental impacts of a proposal before making decisions. An environmental impact statement (EIS) must be prepared for all proposals with probable significant adverse impacts on the quality of the environment. The purpose of this checklist is to provide information to help you and the agency identify impacts from your proposal (and to reduce or avoid impacts from the proposal, if it can be done) and to help the agency decide whether an EIS is required. INSTRUCTIONS FOR APPLICANTS This environmental checklist asks you to describe some basic information about our proposal. Governmental agencies use this checklist to determine whether the environmental impacts of your proposal are significant, requiring preparation of an EIS. Answer the questions briefly, with the most precise information known, or give the best description you can. You must answer each question accurately and carefully, to the best of your knowledge. In most cases, you should be able to answer the questions from your own observations or project plans without the need to hire experts. If you do not know the answer, or if a question does not apply to your proposal, write "do not know" or "does not apply." Complete answers to questions now may avoid unnecessary delays later. Some questions ask about governmental regulations, such as zoning, shoreline, and landmark designations. Answer these questions if you can. If you have problems, the governmental agencies can assist you. The checklist questions apply to all parts of your proposal, even if you plan to do them over a period of time or on different parcels of land. Attach any additional information that will help describe your proposal or its environmental effects. The agency to which you submit this checklist may ask you to explain your answers or provide additional information reasonably related to determining if there may be significant adverse impact. USE OF CHECKLIST FOR NON -PROJECT PROPOSALS Complete this checklist for non -project proposals, even though questions may be answered "does not apply." In addition, complete the Supplemental Sheet for Non -Project Actions. For non -project actions, the references in the checklist to the words "project," "applicant," and "property or site" should be read as "proposal," "proposer," and "affected geographic area," respectively. RECEIVED AUG 29 2012 Bulletin #050 — January 1, 2011 Page 1 of 18 k: t fli IAktist Cps BACKGROUND INFORMATION Property Owner: South King County Fire & Rescue Address: 31617 1st Avenue South City/State/Zip: Federal Way, WA Phone: Applicant: T-Mobile Address: 19807 North Creek Parkway City/State/Zip: Bothell, WA 98011 Phone: (425) 398-7600 Agent: RealCom Associates - Allison Zike Address: 14432 SE Eastgate Way, Suite 260 City/State/Zip: Bellevue, WA 98007 Phone: (425) 274-4444 ext. 112 Name of Proposed Project: "1:-Mobile SE04693 Mirror Lake Location of Project: Address: Quarter: Tax Parcel Number(s): Federal Way, Washington 33616 21 st Avenue SW Section: 7 Township: 21 Range: 4 0721049210 4. Date checklist prepared: August 21, 2012 5. Agency requesting checklist: City ol'Tederal TAT'ay 6. Proposed timing or schedule (including phasing, if applicable): The construction xill commence as soon as all applicable pehniils are obtained. 2. Do you have any plans for future additions, expansion, or further activity related to or connected with this proposal? If yes, explain. At this 011ie, T 11oblle does not hai e pbuis for 1Ulum additions, mpansious, or luoure activity comlected rrilh this project. However in the future, mal*cl cone lions could necessitate the ]feed 101' a(khOUllal alhlClll]aS at this location. 8. List. any environmental information you know about that has been prepared, or i ' be prepared, directly related to this proposal. T-Mobile and its agents ale not ar-flare ofally precious enTironmental infoiniation that has been prepared on tie project site that would adecl this proposal other dhalh previous SEPA Checklists subnlitled to tie City of Federal Way for the ex7sling telecommuliicatiou la fides. T-Mobile SE04693 Mirror Lake SEPA Checklist - Page 2 9. Do you know whether applications are pending for governmental approvals of other proposals directly affecting the properly covered by your proposal? If yes, explain. T-Mobile and its agents are not ar-we ol'vey applications) pendmggovenrmental approvals) that would directly allect the property covered by this project. 10. List any government approvals or pen -nits that will be needed for your proposal, if known. The T-Mobile SE04693 Mirror Lie project requires the follornrrg approvals: ■ Process III Land -Use Review • State Enraronmeutal Policy Act (SEPA) Review ■ Commercial Building Permit 11. Give brief, complete description of your proposal, including the proposed uses and the size of the project. There are several questions later ui this checklist that ask you to describe certain aspects of your proposal. You do not need to repeat those answers on this page. (Lead agencies may modify this form to include additional specific information on project description.) The applicant, T-Mobile, proposes to modify au existurg telecommunication facility located at 31617 F Ave South (Parcel No. 0721049210) to pror4de expanded serraces. The proposed modification consists oftlie follou ng.• Replace/upgfade six (6) existing antennas; add three (3) nera vrtemras fora total ol'irine (9). Please see Sheet A-1.2 and A-2 for additional information. 12. Location of the proposal. Give sufficient information for a person to understand the precise location of your proposed project, including a street address, if any, and section, township, and range, if known. If a proposal would occur over a range of area, provide the range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and topographic map, if reasonably available. While you should submit any plans required by the agency, you are not required to duplicate maps or detailed plans submitted with any permit applications related to this checklist. 77re project is located at 316171" Ave Soulh, Federal 147aj; N,askiigion rridlin King Counly. Please see the Aerial-Vicinili, Map in the SE PA E hihils for more detailed infornalion. B. ENVIRONMENTAL ELEMENTS l 1. Earth conaKir W G%C ��►6� �q I a. General description of the site (underline one): flat, rolling, hilly, steep slopes, mountainous, outer: b. What is the steepest slope on the site (approximate percent slope)? In the area dial the teleconnnunicatioir facility is proposed, the steepest slope is approximated at less than percent (50). T-Mobile SE,04693 Minor LAe SEPA Checklist - Page 3 c. What general types of soils are found on the site (for example, clay, sand, gravel, peat, muck)? If you know the classification of agricultural soils, specify them and note any prune farmland. The general types of-soillound on the site are not knomi. d. Are there surface indications or history of unstable soils in the immediate vicinity? If so, describe. There are no surface indications and/or history of unstable soils in die immediate rocmity of the project. e. Describe the purpose, type, and approximate quantities of any filling or grading proposed. Indicate source of fill. There is no proposed grading associated with this project. f. Could erosion occur as a result of clearing, construction, or use? If so, generally describe. Erosion is very unlikely. Homever, Best Management PM, Ctices OMP's) for erosion control will be implemented duringconstuction. g. About what percent of the site will be covered with impervious surfaces after project construction (for example, asphalt or buildings)? T-Mobile is not proposing vhy newimpenaous surlaces. h. Proposed measures to reduce or control erosion, or other impacts to die earth, if any: 3. Air All standard erosion conti-ol methods will be utilized to reduce or control erosion, or otherinhpacts to the earth. Cc711Clnr W CIIS l —C) a. What type of emissions to the air would result from the proposal (i.e., dust, automobile, odors, industrial wood smoke) during construction and when the project is completed? If any, generally describe and give approximate quantities if known. During- construction, there Will be very minor dust and emissions associated a d1 construction madlinei7/r elhicles. There are no signrlicant emissions associated u411i project operation. b. Are there any off -site sources of emissions or odor that may affect your proposal? If so, generally describe. T-Mobile and its agents are not arrwe of any ofTsite sources ofemissions or odor that mould affect this proposal. T-Mobile SE04693 Mimi- Lake SEPA Checklist - Page 4 c. Proposed measures to reduce or control emissions or other impacts to air, if any: All standard measures to reduce and/or control emissions during construction uiU be utilized. These measures inay include the regular use of'watering vehicles to attenuate dust pavticles on -site and proper rnainten lice ofall vehicles to limit emissions. 4. Water a. Surface: C'ahCO( lr C��rl�lt�l' C�►-d) (1) Is there any surface water body on or in the immediate vicinity of die site (including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)? If yes, describe type and provide naives. If appropriate, state what stream or river it flows into. Mirror Lake is approximately 950 Ieet away fi-om the existing toner. It is unl nouw what steams or fivers Mirror Lake flows into. No Ke- (2) Will the project require any work over, in, or adjacent to (within 200 feet) the described waters? If yes, please describe and attach available plans. This project gill not require any w otA over, m, or adjacent to (within 2001eet) ofaily waters. (3) Estimate the amount of fill and dredge material that would be placed in or removed from surface water or wetlands and indicate the area of die site that would be affected. Indicate the source of fill material. This project will not fill and/or dredge material lrom sullace watei/wetlands. (4) Will die proposal require surface water wididrawals or diversions? Give general description, purpose, and approximate quantities if known. This project mill not iequire suilice water rritlidlarrals or diversions. (5) Does the proposal lie within a 100-year floodplain? If so, note location on the site plan. This project does not lie within a 100Deal-floodplain. Please see [he EEMA Map in the SE, PA Exhibits Ior more detailed uilonnation. (6) Does die proposal involve any discharges of waste materials to surface waters? If so, describe the type of waste and anticipated volume of discharge. This proposal does not invoke ally dischvges of waste materials to suilace waters. b. Ground: (1) Will ground water be withdrawn, or will water be discharged to ground water? Give general description, purpose, and approximate quantities if known. T-Mobile SE04693 Mirror Lake SEPA Checklist - Page 5 No g-oundraaler Ta711 be Taathdrarvrh md/or Taater disclharged to tie g-oundraater: (2) Describe waste material that will be discharged into the ground from septic tanks or other sources, if any (for example: domestic sewage; industrial, containing the following chemicals ...; agricultural; etc.). Describe the general size of die system, the number of such systems, d-ie number of houses to be served (if applicable), or the number of animals or humans the system(s) are expected to serve. No raasle mateiiVs mall be discharged into the p-ound from septic tanks or other sources. C. Water Runoff (including storm water): (1) Describe the source of runoff (including storm water) and method of collection and disposal, if any (include quantities, if known). Where will this water flow? Will this water flow into other waters? If so, describe. The project rail] not alter or rmpacl the existing storm drainage system. (2) Could waste materials enter ground or surface waters? If so, generally describe. This tJpc project does not generate raaste materials. Therelore, it is Tejy unlikely that raasle matehials would enter the ground or suilace waters, however all preventive measures mall be taken. d. Proposed measures to reduce or control surface, ground, and runoff water impacts, if any: 4. Plants At this time, there are no proposed measures to reduce or control surface Taater g-oundrTaler, and runofl: COT" V;A C ts� �a_ d) � a. Check or circle types of vegetation found on the site: X deciduous tree: alder maple, aspen, other X eierg7cen tree: fn-, cedar, pine, other _X shrubs X '-2-ass -- pasture -- crop org-vn wet soil plants: catlad, buttercup, bullmsh, skunk cabbage, other walerplants: Tvaterlilj; eelgass, milfoil, other other tjpes of vegetation b. What kind and amount of vegetation will be removed or altered? No vegelatiou Taal] be removed c. List threatened or endangered species known to be on or near the site. No threatened vhd/or endvigered plant species are knoram to be on or near tie site. T-Mobile SE04693 Mirror Lake SE PA Checklist - Page 6 d. Proposed landscaping, use of native plants, or other measures to preserve or enhance vegetation on the site, if any: At this time, rro Ivrdscapinghas been proposed. 5. Animals Co w v r-4 C taW sF (") a. Underline any birds and animals that have been observed on or near the site or are known to be on or near the site: birds: bar4Z, heron, eagle, songbirds, other: mammals: deer, bear, elk, bearer, ulBcrr fish: bass, salmon, trout, Bening, shellfish, other: b. List any threatened or endangered species known to be on or near the site. No threatened vid/or endangered ,vernal species are knorui to be on ornear die site. c. Is the site part of a migration route? If so, explain. T-Mobile and its agents are not amwe of i migration route near the site. d. Proposed measures to preserve or enhance wildlife, if any: AI this lime, lhcrt at a no plvposed measures to preserve or enh.urcr I tif,111 c. 1\ 6. Energy and Natural Resources or�Nr TA INC;kltS� C a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to meet the completed project's energy needs? Describe whether it will be used for heating, manufacturing, etc. Electric porr•er rrill be utilized to operate the anteimas and associated electiical equipment. b. Would your project affect the potential use of solar energy by adjacent properties? If so, generally describe. The subject proposal Trill not a1kct Me potential use of'solar energy by adjacent properties. c. What kinds of energy conservation features are included in the plans of this proposal? List other proposed measures to reduce or control energy impacts, if any: At this time, there are no energy consen atron features included in the plans of tlrrs proposal. T-Mobile SE04693 Mirror Lake SEPA Checklist - Page 7 7. Environmental Health C'01\MY V;6 C4vc�C,,A. Ca—bi a. Are there any environmental health hazards, including exposure to toxic chemicals, risk of fire and explosion, spill, or hazardous waste, that could occur as a result of this proposal? If so, describe. No sucli Hazards have been identified raids other similariiistallations. (1) Describe special emergency services that might be required. No special emergency ser0ces will be required for this proposal. (2) Proposed measures to reduce or control environmental health hazards, if any: At this time, there have been no measures proposed to reduce or control emdronmental health hazards. b. Noise (1) What types of noise exist in the area which may affect your project (for example: traffic, equipment operation, other)? There is not anj, existingnoise m the area that would affect this project. (2) What types and levels of noise would be created by or associated with the project on a short-term or a long-term basis (for example: traffic, construction, operation, other)? Indicate what hours noise would come from site. There will be nnnor shod -[elm noise associated uiti tie constiuction phase of die project. There Tiill be no new significant noise associated ualh operation oftie project. (3) Proposed measures to reduce or control noise impacts, if any: T-Mobile will comply with all slate and local ordinances regn-dingnoise. 8. Land and Shoreline Use iS+ (- C_�nGKr � Cheer � a. What is the current use of the site and adjacent properties? 71 c subject propeayis used by the South King CountyFiie & Rescue as afire station. 77ie adjacenl propellies accommodate coininercnl and residential. b. Has the site been used for agriculture? If so, describe. This properly has not been used for agiicullure. T-Mobile SE04693 Mirror Lake SPPA Checklist - Page 8 c. Describe any structures on the site. The fire station exists on the property. d. Will any structures be demolished? If so, what? No structures will he demolished. e. What is the current zoning classification of the site? The site is zoned RS 9.6 by the City of Federal Way Please see the Zoning Map in the SEPA Exhibits for mole detailed information. f. What is the current comprehensive plan designation of the site? The City ofFederal Wayhas deemed this area Residential SI r101!�Q FaM��y9� g. If applicable, what is the current shoreline master program��designation of the site? Not appEcable to this project. g. Has any part of the site been classified as an "environmentally critical" area? If so, specify. T-Mobile and its agents are not aware of the suhject area for the proposal being classified as "en nti onmentally serrsrt7Ve ". i. Approximately how many people would reside or work in the completed project? The licilily is unmarmed. Orre (1) to two (2) employees are on -site for xi average offour (4) hours of monthly manitenance checks. This check Is typically for preventim maintenance purposes. In the erenl ol'a problem, a crewis dVpaldred to the site imrnediale#J J. Approximately how many people would the completed project displace? Tlris proiecl will nol displace any people. k. Proposed measures to avoid or reduce displacement impacts, if any: This project Trill nor displace anypeople, therefore no measures are needed to ar oid orreduce displacement rmpacls. T-Mobile SE04693 Minor Lake SEPA Checklist - Page 9 1. Proposed measures to ensure the proposal is compatible with existing and projected land uses and plans, if any: T-Mobile's additional a itennas are bens" attached to the existing tower next to their existing- vutennas. Please see the enclosed photo simulations. Tlie antemras aurd associated mountirug- lixdrnaue will be painted to match the existing tower to be as non-mtrusir e as possible. 9. Housing a. Approximately how many units would be provided, if any? Indicate whether high, middle, or low-income housing. No units will be pro Tided by dris project. b. Approximately how many units, if any, would be eliminated? Indicate whether high, middle, or low-income housing. No wets will be eliminated by this project. c. Proposed measures to reduce or control housing impacts, if any: Tlris project mill not impact housing, theuelbre uuo measures ve needed to reduce or control housing impacts. 10. Aesthetics C p k\r W'h 04C*A%9� 4A _ G) a. What is the tallest height of any proposed structure(s), not including antennas; what. is the principal exterior building material(s) proposed? The proposed additional antennas will be attached to die existing one -hundred ,wd 11f[y (150) loot monopole torTer: b. What views in the immediate vicinity would be altered or obstructed? T-Mobile's additional vrtennas ve being attached to the existing monopole toner next to their existing antennas. The site will be risible; horremer die proposed location oldie liciAly does not impede riews olany significant rierascapes such as die lake, mountain views, vrd/or mpxisime views. Please see die enclosed Photo Simulations. c. Proposed measures to reduce or control aesthetic impacts, if any: T-Mobile's additional mrlemras ve being attached to die existing monopole louvr 11ex7 to dreiu- existing antennas. Please see the enclosed Pliolo Simulations. The anteumas and associated mountirrglixdware will be painted to match the existirugrnonopole to blend with die sunoundingenrironment. T-Mobile SE04693 Mirror Lake SEPA Checklist - Page 10 11. Light and Glare Con UV_ U, r),h 04g t%J ( - -4 a. What type of light or glare will the proposal produce? What time of day would it mainly occur? Generally, this proposal will not produce arrylight and/orglare. b. Could light or glare from the finished project be a safety hazard or interfere with views? Generally, tlus proposal Kill not produce any light and/w-glare. c. What existing off -site sources of light or glare may affect your proposal? There are no existing oll=site sources of gllt orglare that will affect this proposal. d. Proposed measures to reduce or control light and glare impacts, if any: Generally, dus proposal H,7II not produce ujy light and/orgl u e impacts. 1 12. Recreation ,p h c" r W ►� a'&k� _C I a. What designated and informal recreational opportunities are in the immediate vicinity? No recj eational opporlunities were noted in the immediate racinity oftre project. b. Would the proposed project displace any existing recreational uses? If so, describe. This project r+ould not displace vey austingrecreational uses. c. Proposed measures to reduce or control impacts on recreation, including recreation opportunities to be provided by the project or applicant, if any: This project mould not displace any evstingrecieatiomd uses, therefore no measures are needed to reduce or control recreation oppor l unities. 13. Historic and Cultural Preservation C orLuAr w h r� R-c a. Are there any places or objects listed on, or proposed for, national, state, or local preservation registers known to be on or next to the site? If so, generally describe. TMobile and its agents ve not ar w-c ofany places or objects listed on, or proposed for-, national, state, or local preservation registers ImoTni to be on orneit to the project. T-Mobile SE, 04693 Mirror Lake SPPA Cliecklist - Page 11 b. Generally describe any landmarks or evidence of historic, archaeological, scientific, or cultural importance known to be on or next to the site. T-Mobile vid its agents are not aware ofviy Ividmar*s, or ei4dence ol'bistwical, rrhaeological, scienafic, or cultural importance to be on or next to die project. c. Proposed measures to reduce or control impacts, if any: T-Mobile's additional antelmas are being attached to die existing monopole tower -next to their exisdugautennas. Please see the enclosed Plioto Simulations. The vhtennas and associated mounting hardware will be painted to match the existing monopole tower to blend with die surrounding environment 14. Transportation C"C4Ar 'nth a. Identify public streets and highways serving the site, and describe the proposed access to the existing street system. Show on site plans, if any. The project is located o11'F Arse Soudi. (Please see Vicinity Map Exhibit) b. Is site currently served by public transit? If not, what is the approximate distance to the nearest transit stop? Not applicable to this project. c. How many parking spaces would the completed project have? How many would the project eliminate? On-sile paiking-bas been provided for maintenance vehicles. c. Will the proposal require any new roads or streets, or improvements to existing roads or streets, not including driveways? If so, generally describe (indicate whether public or private). This proposal Till not requil-e any nernroads or styeels. e. Will the project use (or occur in the immediate vicinity of) water, rail, or air transportation? If so, generally describe. This is an umnanned facility wid will not require die use of water, 1wi1 or yr tMI)SpOl-1,7 011. d. How many vehicular trips per day would be generated by the completed project? If known, indicate when peak volumes would occur. The facility will be ulmlvined. One (1) to two (2) ,u intenance visits permondi is eipected. g. Proposed measures to reduce or control transportation impacts, if any. There are no traffic impacts associated wadi these types of facilities as they are unmvnied and require nifrequent maintenvice, therefore no measures are needed to reduce or control transportation impacts. T-Mobile SE04693 Minor L.A-e SEPA Checklist - Page 12 15. Public Services can eu Y ,,a h 6,►sf (q ---b� a. Would the project result in an increased need for public services (for example: fire protection, police protection, health care, schools, other)? If so, generally describe. This project will not result in 8n increased need for pubLc serrates. b. Proposed measures to reduce or control direct impacts on public services, if any. This project will not result in an increased need for public seiTaces, therefore no measures are needed to reduce or control direct impacts on public services. 16. Utilities tA,+k 0e0k1is*- [tea—Q a. Underline utilities currently available at the site: electricity, natural gas, water, refuse service, telephone, sanitary sewer, septic system, other. Electricity.• Puget Sound Energy Telephone: Verizon/QWest b. Describe the utilities that are proposed for the project, the utility providing the service, and the general construction activities on the site or in immediate N rlJt37 which might be needed. Telephone serrate wall be proraded by tie local telephone company. Electrical power wall be pvoraded by the local power prorader: Water-, sewer vrd natural gas ve not required 16r this project. Signature The above answers are true to the best of my knowledge. I understand that the lead agency is relying on them to make its decision. .Slb°71aLr1r'C August 21, 2012 Date T-Mobile SE04693 Minor LA-e SEPA Checklist - Page 13 AERIAL -VICINITY MAP PROJECT NAME: SE04693 Mirror Lk PROJECT ADDRESS: 31617 lst Ave South PROJECT PARCEL NUMBER: 0721049210 T-Mobile SE04693 Mirror Lk SEPA Checklist Exhibit FEMA Map LEGEND ZONE X: Areas determined to be outside 500-year floodplain. T-Mobile SE04693 Mirror Lk SEPA Checklist Exhibit PARCEL MAP PROJECT NAME: SE04693 Mirror Lk PROJECT ADDRESS: 31617 1st Ave South PROJECT PARCEL NUMBER: 0721049210 9013 W30 � 3 9029 9232 9242 TH 9074 S 315ST 9106 0140 9030 01W 0180 9019 9196 9198 Sw 316TH ST 0190 9011 07210492� �.1° 011a v F e 011n d e va I.W. any 0290 0370 �� 0300 0420 040a 9204 00i0 1{?,- S �� 0020 0530 0450 0480 0520 0510 0090 9131 0440 0460 0410 0490 0550 U50a 0080 � 51V 313T N W 0100 {q I RC I aa6{r of 9133 9258 0130 q (G01'2010 KiOOZO V T-Mobile SE04693 Mirror Lk SEPA Checklist Exhibit PROJECT NAME: SE04693 Mirror Lk PROJECT ADDRESS: 31617 1st Ave South PROJECT PARCEL NUMBER: 0721049210 T-Mobile SE04693 Mirror Lk SEPA Checklist Exhibit 19807 North Creek Parkway North Bothell, WA 98011 City of Federal Way - Planning 33325 8th Ave. South Federal Way, WA 98003 Re: T-Mobile - SE04693 Mirror Lake - 31617 1 st Ave South T-Mobile agrees to allow for the potential collocation of additional PWSF equipment by other providers within the same site location. T-Mobile acknowledges that if an applicant contends that future collocation is not possible on their site, they must submit a technical study documenting why (FWRC 19.255.060121). Maria Emig Print N ine �J Signature Development Manager Print Title 6/6/2012 Date RECEIVED AUG 292012 CITY OF FEDERAL WAY CDS Rebecca Chapin From: Rebecca Chapin Sent: Tuesday, September 04, 2012 10:30 AM To: 'azike@realcomassoc.com' Subject: T-Mobile - SE04693 Mirror Lake - Preapp Waiver Hi Allison, The City received your request for Preapplication meeting waiver, received August 30, 2012. Per Federal Way Revised Code 19.40.030(2)(a), due to the simple nature of the proposal, and because the site has previously undergone a site plan review for a similar development proposal, your request for waiver of the required preapplication conference is hereby approved. Please be advised that this waiver of preapplication review may increase the risk of the application being incomplete or that the processing time will be increased. I will continue to review the UPIII application and SEPA checklist and let you know if there questions or comments. Feel free to contact me if you have any questions regarding this project. Thanks, Becky Chapin Assistant Planner Community and Economic Development City of Federal Way 33325 8th Avenue South Federal Way, WA 98003-6325 Phone:253-835-2641 Rebecc a. C h a pi n aRcityoffederalway.com 1 RE L C 0 M August 30, 2012 City of Federal Way - Planning 33325 8th Ave. South Federal Way, WA 98003 Re: T-Mobile - SE04693 Mirror Lk - Pre -Application Waiver Request Dear Federal Way Planning Department: Please accept this letter as T-Mobile's request to waive the pre -application meeting for the proposed site modifications at the SE04693 Mirror Lake site located at 31617 1st Ave South, Federal Way, Washington (Parcel No. 1321039062). Respectfully, Allison Zike Agent for T-Mobile RECEIVED AUG 3 0 2012 CITY OF FFOFRgL WAY CDs RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 P 8ellevue,Washington 98007 Phone (425) 274-4444.S;Fax (425) 274-4449 www.realcomassoc.com RECEIVED MASTER LAND USE APPLICATION 9 qO�q DEPARTMENT OF CONmiuNITY DEVELOPMENT SERVICES 2 L L 33325 8`h Avenue South CITY OF �` _ "� Federal Way, WA 98003-6325 Federal Wav CITY OF FEDERAL WAY 253-835-2607: Fax 253-835-2609 CDs tvww.61yPlTedt ra1w;tvxvm APPLICATION NO(S) 1 ~ 1 a 410 V W v? - 1 v11( 01S- Date ,� 1 1 k4-- Project Name T-Mobile - SE04693 Mirror Lake 31617 1 st Ave South Property Address/Location 0721049210 Parcel Number(s) Modify existing telecommunication facility by upgrading/replacing six (6) existing antennas Project Description B w antennas. PLEASE PRINT Type of Permit Required _ Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone _ Land Surface Modification _ Lot Line Elimination Preapplication Conference Process I (Director's Approval) Process II (Site Plan Review) II Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) _ Process VI SEPA w/Project SEPA Only _ Shoreline: Variance/Conditional Use Short Subdivision _ Subdivision Variance: Commercial/Residential Required Information RS-9.6 Zoning Designation Comprehensive Plan Designation Value of Existing Improvements $30,000 Value of Proposed Improvements International Building Code (IBC): Telecom ELOccupancy Type Telecom Construction Type Applicant Name: T-Mobile Address: 19807 North Creek Parkway North City/State: Bothell, WA Zip: 98011 Phone: Fax: Email: Signature: Agent (if different than Applicant) Name: RealCom Associates - Allison Me Address: 14432 SE Eastgate Way, Suite 260 CitylState: Bellevue, WA 98007 7.i : p Pp: (425) 274-4444 ext. 112 Fax: (425) 274-4449 Email: azike@realcomassoc.com Signature: Owner South King County Fire & Rescue Name: Address: 31617 1 st Avenue South city/state: Federal Way, WA Zip: 98003 Phone: (253) 839-6234 (253) 529-7204 Email: Signature; 1. _;� �� Bulletin #003 — January 1. 2011 Pale I of 1 k:\Hand0utsVN4as1er Land Use Application d VICINITY MAP � son %. a 4a Sw 308BI St -FFiriw ukr N SITE Lgg4TJON �a towk n F+ K5 y a a 4 FedenlYry to S 3171A U a V SW 390V+ St 5 .zm St. 9q `t y SIh PI. N N ZS 1p 3: LEGAL DESCRIPTION PCL B OF FEDERAL WAY LLA #BLA95-0011 REC #9610289005 SO LLA LOCATED IN NE 1/4 OF BE 1/4 OF SE 1/4 OF SEC 7-214 LESS FOR FOR RD APPROVAL/SIGN OFF OF DRAWINGS CONSULTANT GROUP SIGN OFF DATE INITIAL AND PRINT NAME LANDLORD'S REPRESENTATIVE CONSTRUCTION COORDINATOR PROJECT MANAGER SITE ACQUISITION ZONING RF ENGINEER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED T Mobile •' MIRROR LAKE/C I N G U LAR/KC FIRE 31617 1 st AVENUE S FEDERAL WAY, WA 98003 KING COUNTY S E 04693A LATITUDE 470 19' 07.3" N LONGITUDE 1220 20' 09.6" W AT&T TOWERS #: 11602-A GENERAL LOCATION MAP 1 f iW►A SITE LOCATION I -all ,N mw 1 • r .�� � � w 4 If t• �e.r :. 1 DRIVING DIRECTIONS FROM T-MOBILE BOTHELL OFFICE: HEAD TOWARD NE 195th ST ON NORTH CREEK PKY, GO 0.2 MI TURN RIGHT ONTO NE 195th ST, GO 0.3 MI TURN LEFT AND TAKE RAMP ONTO 1-405 S TOWARD RENTON, GO 24.3 MI CONTINUE ON WA-518 W, GO 521 FT TAKE THE 1-5 &PORTLAND EXIT ONTO 1-5 S. GO 10.6 MI TAKE EXIT #143/FEDERAL WAY/S 320th ST, GO 0.3 MI TURN RIGHT ONTO S 320th ST. GO 1.6 MI TURN RIGHT ONTO 1st AVENUE S, GO 0.2 MI YOUR DESTINATION ON 1st AVENUE S. IS ON THE LEFT THE TRIP TAKES 37.7 MI & 43 MINS PROJECT TEAM APPLICANT: PROGRAM MANAGEFL T-MOBILE REALCOM ASSOCIATES 19807 NORTH CREEK PARKWAY MATT CAGAN BOTHELL, WA 98011 (206) 948-3408 CONSULTING ENGINEER: CONSTRUCTION PROJECT MANAGER: CORNERSTONE ENGINEERING, INC. REALCOM ASSOCIATES 16928 WOODINVILLE REDMOND ROAD NE SUITE 210 JULIA RUZON WOODINVILLE, WA 98072 (206) 604-1895 MARK W OLSON, P.E. CONSTRUCTION COORDINATOR: PH: (425) 487-1732 FAX: (425) 487-1734 REALCOM ASSOCIATES JULIA RUZON PROJECT CONSULTANT: (206) 604-1895 REALCOM ASSOCIATES 14432 SE EASTGATE WAY, SUITE 260 SITE ACQUISITION: BELLEVUE, WA98007 REALCOM ASSOCIATES FAX: (425) 2744449 NANCY SEARS (425)444-1434 PROPERTY OWNER: FIRE DISTRICT #39 712777 ZONING: 31617 1st AVENUE S REALCOM ASSOCIATES FEDERAL WAY, WA 98003 SARAH TELSCHOW (425) 274-4444 EXT. 114 ER OWNER: TOWER stelschow@realcomassoc.com 6100 ATLANTIC BLVD RF ENGINEER: NORCROSS, GA30071 T-MOBILE DARRYL SALK (425)770-0006 PROJECT INFORMATION CODE INFORMATION: PARCEL NUMBER: ZONING CLASSIFICATION: RS9.6 0721049210 BUILDING CODE: IBC 2009 AREA OF PARCEL: CONSTRUCTION TYPE: II-B NON-COMBUSTIBLE ±87,120 SQ. FT. (2.0 ACRES) JURISDICTION: FEDERAL WAY PROPOSED BUILDING USE: TELECOMM PREVIOUS PERMIT APPROVALS: FWHE 98-07, UP4-98-0001, & 04-102732-00-CO GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. (NON ASSIGNED TECH PARKING) 2. TRAFFIC IS UNAFFECTED. 3. NO SIGNAGE IS PROPOSED. PROJECT DESCRIPTION I THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF THE REMOVAL/REPLACEMENT OF (6) EXISTING ANTENNAS AND ADD (3) NEW ANTENNAS WITH TOTAL OF (9) NEW TMaM-6516 UM ANTENNAS; ALSO THE ADDITION OF (2) FXFB UNITS, (3) FRIG UNITS AND COLLAR MOUNT TO AN EXISTING MONOPOLE; ALSO THE ADDITION OF (1) HYBRID CABLES, (2) COVP UNITS (1 NEAR ANTENNAS AND 1 NEAR THE SITE SUPPORT EQUIPMENT) ON AN EXISTING CONCRETE SLAB WITHIN AN OPEN-AIR SHELTER. RECEIVED AUG 292012 CITY OF FEDERAL WAY CDS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TOT -MOBILE WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED. DRAWING INDEX DWG DESCRIPTION T-1 TITLE SHEET G-1 GENERAL NOTES A-1 SITE PLAN A-1.1 EXISTING ENLARGED SITE PLAN A-1.2 I PROPOSED ENLARGED SITE PLAN A-2 SOUTH ELEVATION A-2.1 PROPOSED NORTH, EAST & WEST ELEVATIONS A3 DETAIL SHEET A3.1 DETAIL SHEET E-1 SCHEMATIC GROUNDING PLAN & DETAILS RF-1 RF DETAILS RF-2 RF DETAILS PROJECT INFORMATION I THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. T-MOBILE CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED ONLY BY T-MOBILE EMPLOYEES AND THE WORK ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES. PURSUANT TO THE AMERICANS WITH DISABILITIES ACT (ADA), APPENDIX B SECTION 4.11. (5) (B), THIS FACILITY IS EXEMPT FROM THAT ACT. NO POTABLE WATER SUPPLY TO BE PROVIDED AT THIS LOCATION NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS LOCATION. T-MOBILE MAINTENANCE CREW (ONE PERSON) WILL MAKE AN AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER TRIP. CALL TWO WORKING DAYS BEFORE YOU DIGI It 811 NATIONAL UTILITIES UNDERGROUND LOCATE E,ecrwc-eED rv-awWDe SKEIVPNETDRPQBHMLE�PIHB�IEDeY SEWER-DREEN IroSED-WNDE cama�CTDpy­xhn.n.we E. c,,sai�-�w�rc w�TEa-EwE T - Mobile 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: �� �crwpigh1�18TCN8 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 9W72 PHONE: 425X: .487.1732 FA425.487.1734 EMAIL: mi@wmemtone-engnwm W W W.CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR — CCONSTRUCTION �REV::DATE: =ISSUED FOR: BY: DRAWN BY:=CHK.: APV.:' JRF DRA MWO =CURRENT ISSUE DATE: I Ir'ChICI lGF• 08-16-12 B ue(t-L DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORSAND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARESUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTIHNM IN THIS SET OF DOCUMENTS IS PROPRx tARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS 57RK:TLYPROH113rrED TITLE SHEET :DRAWING NUMBER: T-1 0 CEI JOB NUMBER: 12-06007 GENERAL NOTES: 1. DRAWINGS ARE NOTTO BE SCALED.WRI TTIIN DIMENSIONS TAKE PRECEDENCE, THLSSET OF DCCLPMENTS 15 WTENOED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED OTHERWISE- THE GENERAL CONTRACTORS SCOPE OF WORK SHIALL INCLUDE FURNISHING ALL MATERALS, SOUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE PROJECT AS DESCRIBED IN THE DRAWINGS AND DINNER'S PROJECT MANUAL 2. PRIOR TO THE SUBMISSION OF II CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILLLMZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTIONICONTRACI DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WIL HE AGGDMPLISHEDAS SHOWN. FRIORTO PROCEEDING WITH CONSTRUCTM. ANY ERRORS. OMISSIONS, CR DISCREPANCIES SHALL BE BROUGHT 70 THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 3. THE AFICHITECTWENGIWEPS HAVE MADE EVERY EFFORTTO SET FORTH 9N THE CONSTRUCTION AND CONTRACT OOCUMENM THE COMPLETE SCOPE OF WORK. CONTRACTORS SIODWG THE JOB ARE NEVERTHELESS CAVTI0NE0 THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT E=)SE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS- THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING ON WRITOHI)THE ARC>-BTEi7+ENGINEERAFANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO S1IBMISSIQN OFCOFTLRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK UNLESS DIRECTED OTHERWISE. 4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS- THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES. SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. S. THE CONTRACTOR SHALL IN STALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S /t;NDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 6 ALL WORK PERFORMED ON IMF PROJECT AND LATERALS INSTALLED SHALL. BE IN STRICT ACCORDANCE WTHALL APPLICABLE CODES, REGULATIONS. AND ORDINANCES. CONTRACTOR WILL GIVE ALL NOTICES ANO COMPLY VATS ALL LAWS. ORDINANCES, RULES. REGULATIONS AND LAWFUL. ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE Wow 7. GENERA, CONTRACTOR SHALL PROVIDE. AT THE PROJECTSITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT- THIS SET IS A VAUDCONTITACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED TORCONSTRUCTK)N'AND EACH SUOCESSNESHEET BEARS THE ARCHITECTS SIGNED WET STAMP 8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE 10 CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING OFNOT LESS THAN 2-A OR 2"A1 BBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION 11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT E)OSTING IMPROVEMENTS, EASEMENTS, PAYING, CURSING, ETC- DURING CONSTRUCTION. UPON COMPLETION OF WORTS CONTRACTORSHALL REPAIR ANY DAMAGE THATMAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12 CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION ANO DISPOSE OF ALL GIRT, OEBRi%AND RUBBISH. CONTRACTORSHALL REMOVE ECUiPWENTNDT SPEGFIEO AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN COF401TEON AND FREE PROM PAINT SPOTS. DUST, OR SMUDGES OF ANY NAIJRE 13 THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 15 THE CONTRACTOR SHALL PROVIDE THE CLIENT PROPER INSURANCE CERTIFICATES NAMING CLIENTAS ADDMONAL INSURED, AND CLIENT ALOOF OF LICENSE(S) AND PE & PD INSURANCE. 16 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. 17 CAUTIONI CALL BEFORE YOU DIG? BURIED UHLITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOTEE COMPLETE. CONTACT THE ONE -CALL UTL17Y LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION DIAL B11 18 CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO CLIENT ALONG WITH RECLINED CONSTRUCTION SET. 19 CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP(R.EDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE RECLINED SET TO THE CLIENT UPON COMPLETION 20 FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK 21. GENERAL CONTRACTOR $ TQ COORDINATE ALL POWER INSTAL ATLON WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POVVM INSTAUATp)NCOOROINA7MN SOLUTLON[S)TO NETWORK CARRIER REPRESENTATIVE. PROJECT CONSTRUCTION MANAGER AND ARCHITECT, 22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY CLIENT CONSTRUCTION MANAGER 23 IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AJNDIDR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR THE GENERAL CONTRACTOR SHALL COORDINATE YWTH BUILDING OWNER AND SO HLOING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH. REPAIR OR ANY AUGMENTATION TO THE ROOF. AND RAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTORS WARRANTY FOR MOETURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 24. IN THE CASE OF ROOFTOP SOLUTIONS WRNS THE INSTALLATION OF ANTENNAS WITH IN CONCE&FD (SHROUDT DOMPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DES?GNFJLFABRJCATORTo ENSURE THATTHE FINAL FRP SHROUD IS SIMULATING PN APPEARANCE)OESIGNATED EXISTLHG EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, ASO COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION, WHEN PHOTO SIMULATIONS ARE PROVIDED. THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT 15 INDICATED IN PHOTO SIMULATIONS. SHOP DRAWNGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR CONSTRUCTION COORDINATOR AND ARCHITECT PRIOR TO FABRICATOR AND CONSTRUCTION. GENERAL NOTES [CONTU , 25. IN THE CASE OF ROOFTOP SOLUTIONS MR EQUIPMENT ANDIOR ANTENNA FRAMES WHERE ANCHORING 70ACONCRETE ROOF SLAB IS REQU IREO, CONTRACTORS SHALL CONFIRM (FIN ORTO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE RODFSLAB - RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING'ASEUB-T DRAWING SET'- HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE WJ EMBEDDED STEEL REPAR IN THE EYENT POST TENSION SLAB SOLUTION IS PRESENT. CONTRACTOR SHALL INCLUDE PROVISIONS FOR X.RAY PROCEDURES (INOLUCED IN MID) FOR ALL PENETRATM NAREAS VWERE ANCHORING OCCURS 26. GENERAL d SUB CONTRACTDRS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE OOWNNS (WHERE APPLICABLE) PLASTIC ZIP TIES SHALL NOTEE PERMITTED FOR USE. ON CLIENT PROJECTS- RECOMMENDED MANUFACTURE SHALL BE PANDUIT TARP, METAL LOCKING TIES MODEL NO. MLT4S4,P UNDER SERIES-304(OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRAM OF TACO A. WA DESIGN CRITERIA: 1- THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2009 WITH WASHINGTON STATE BUILDING CODE AMENDMENTS (IBC 2009) 2. DESIGN EOADS DESIGN DATAFOR FEDERAL WAY, WA: -ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) -BASIC WIND SPEED 85 MPH (3 SEC GUST) -WIND EXPOSURE B CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED ME) INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED SY THE LOCAL GOVERNING AIJTHOMTIES. NOTHING ON THESE BANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT OCNFCALMING TO THESE CODES: 2009 INTERNATIONAL BUILDING CODE 2" INTERNATIONAL RESIDENTW. CODE 2008 INTERNATIONAL MECHAN[CAL CODE 20M INTERNATIONAL FUEL GAS CODE 20M NFPA 54- NATIONAL FUEL GAS CODE 2009 INTERNATIONAL FIRE CODE (PROPANE INSTALLATIONS ONLY} 200E UNIFORM PLUMBING CODE 20P9 NFPA58-LROUEIED PETROLEUM GAS CODE Y008 WPA TO NATIONAL ELECTRICAL CODE (PROPANE INSTALLATIONS ONLY) mu NATKWAL ELECTRIC SAFETY CODE LOCAL BUILDING CODE ORDINANCES 2W9 ANSI ITA. /ETA-T33-G 2009 WASH INGTON STATE ENERGY CODE NFPA-101 - LIFE SAFETY CODE ICC/ANSI Al 17.1-20M 2009 INTERNATIONAL EXISTING BUILDING CODE WITH STATE WIDE AMENDMENTS FOUND IN THE IBC CONCRETE NOTES: 1 ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI316 2 CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 19 OF THE IBC 2009. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. TYPE OF CONSTRUCTION 28 DAY STRENGTHS W/C MINIMUM CEMENT TO RATIO CONTENT A. SLABS ON GRADE PERCUBIC YARC TOPPING SLABS CONCRETE PIERS 3,000 PSI 1 45 5112 SACKS B. ALL STRUCTURAL CONCRETE 4,000 PSI '_ .45 612 SACKS EXCEPT WALLS C CONCRETE WALLS 4.000 PSI ` AS 612 SACKS CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U N O. 3 THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT 4. ALL CONCFZMWTH SURFACES ELPOSEDTOSTANDING WATER SHALL BE AIR -ENTRAINED WITH ANANR.ENTRAINING AGENT CONFORMING TO ASTM C26D,C494,G8IM CABS AND C1017. TOTALAIR CONTENT SHALL BE IN ACCORDANCE WITH TABLE IW2.1 OF THE IBC 2009. 5, RHNFORCIW STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT Sl] GRADE B0. 6-iADDD PSI, EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE ORAWINGSSW BE GRADE 4%f1 .000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CQIIFORM TOALSTM AT06 REINFORCINGDOMPLYING WITH ASTM A616(S1) MAYBE WELDED ONLY IP MATIII PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED, 6. REINFORCING STEEL SWILL BE CETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI315AND 31d. LAP ALL CONTINUOUS REINFORCEMENT AT LEAS( 30 EAR DIAMETERS ORA MINIMUM OF T{Y. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER SARSAT LEAST 30 BAR DIAMETERS ORA MINIMUM OFV-W. LAPAWACENTMATS OF WELDED WIRE FABRIC WNLMUM OF If' AT SIDES AND ENDS- 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 8 SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy- 0,000 PSI 9 NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BYTHE CONSULTANT. 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: 3- FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE (#6 BARS OR LARGER) 2' FORMED SURFACES EXPOSED (#5 BARS OR SMALLER) 1 12' TO EARTH OR WEATHER 3/4' 11 SLABS AND WALLS (INTERIOR FACE) 12 BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. 13 ANCHOR BOLTS TO CONFORM TO ASTM A307. 14. NON -SHRINK GROUT SHALL BE R)RNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURERS PUSUSHED RECOMME HOATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 PSI MINIMUM) 15 ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2 STRUCTURAL STEEL OESIGN. FABRICATION AND ERECTIDN IINCLUDING F1 ELO WELDING RICH STRENGTH FIELD SOLTING. EXPANSION BOLTS. AND THREADED F)WANSION ANCHORS)SHALL BE BASED OR THE AI-W, *SPECIFICATION FOR THE %SIGN. FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR SWLDINGS' LATEST EDITION. SUPERVISION SHALL BE INACCORWNCE WITH ISC 2DO9 CHAPTER ZZ BY A QUALIRED TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTSIW0 TEST RESULTS 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A WIDE FLANGE SHAPE ASTFA AV2. Fy 50 KSI B. OTHER SHAPE, PLATES AND ROD ASTM A36, Fy 36 KSI C. PIPE COLUMNS ASTM A53, Fy 35 KSI D STRUCTURAL TUBING ASTM A500, Fy 46 KSI E. ANCHOR BOLTS ASTM A307 F. CONNECTION BOLTS ASTM A325 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00. 5 ALL WELDING SHALL BE IN CONFORMANCE WITH. A.LSJ.AND AWS STANDARDS AND SHALL BE PERFORMED BY WA6-0, CERTIRED WELDERS USING Em XX ELECTRODES. ONLY PREOUAURED WELDS (AS DEFINED BY AVIS) SHALL BE USED, WELDING OF GRADE WREINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELCM OF GRADE 40 REINFORCING EARS OF REGUIREO) S ALL BE PERFORMED USING E713 XX ELECTRODES- WELDING WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS 6. COLO•FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE. AND C-bv SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE A.LS-I. 'SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS.' 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4' DIA) AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. 8 NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8' DA ASTM A307 BOLTS UNLESS NOTED OTHERWISE 9 ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN S CONSTRUCTION SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS FITTED OTHERWISE. 10 ALL WELDS TO BE 1/4' FILLET UNLESS NOTED OTHERWISE. 11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL.' TOWERlPOLE NOTES: 1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA LOADING IS TO BE DONE BY OTHERS 2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INFRAL AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURERS REQUREMEMS. ABBREVIATED ROOFTOP SAFETY PROCEDURES (WHEN APPLICABLE (AS PER'ACCIDENT PREVENTION PROGRAM' BY PERMISSION OF WREN CONSTRUCTION, INC.-03ID1199) FALL PROTECTION METHODS AND EQUIPMENT ROOFTOP INSTALLATIONS 1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS. 2 SAFETY MONITOR SHALL WARR CONSTRUCTION WORKERS OF HAZARDS (LE, BACKM UP TOWARD ROOF EDGE, ETC.)OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CON5TM?CTICN WORKERS. 3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN V OR LESS OF AN UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE 4, SAFETY LINE SHALL BE MINIMUM W DIAMETER NYLON, WITH A NOMINAL TENSILE STRENGTH OF 5400 LBS, S. SAFETY LINE SHALL BE ATTACHED TOASUBSTANTAL MEMBER OF THE STRUCTURE 6- SAFETY LINE LENGTH SHALL BE SETALLOWING CONSTRUCTION WORKERTO REACH EDGE OF ROOF, BUT NOT BEYOND. 7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS. 8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, INCLUDING: INSPECTION OF CONSTRUCTION AREA FOR HAZARDS USE OF AN INSPECTION CHECKLIST INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS REPORTING AND DOCUMENTING ANY HAZARDS REPORTING HAZARDS TO THE SAFETY CG',1MITIEE FOR CONSIDERATION POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN RECEIVING AN UNBIASEO REVIEW OF ONES OWN WORK AREA BY ANOTHER COWORKER SAFETY REPRESENTATIVE REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NATIONAL ASSOCIATION OF TOWER ERECTORS MOO PUBLICATION REFERENCED OSHA REGULATIONfVANDAROS SHALL BE REVIEWED BY TOWER ERECTORS, EQUIPMENT INSTALLERS,ANO TOWSR.0ROOF TCP CONTRACTQRSIRMOCNTRACTURB 29 CFR 192G.S00- SCOPE, APPLICATION, AND DEFINITIONS 29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION 19 CFR 1926.502- FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES SYN. )LS AND ABBREVIATIONS A/C AIRCONDITIONING MAX MAXIMUM AGL ABOVE GRADE LEVEL MECH MECHANICAL APPROX APPROXIMATELY MTL METAL MFR MANUFACTURE BLDG BUILDING MGR MANAGER BLK BLOCKING MIN MINIMUM B.C. BOTTOM OF MISC MISCELLANEOUS B.C.S BOTTOM OF STEEL N/A NOT APPLICABLE CLG CEILING NIC NOTINCONTRACT CLR CLEAR N.S. NEARSIDE CMU CONCRETE MASONRY UNIT NTS NOT TO SCALE CONC CONCRETE CONST CONSTRUCTION O.C. ON CENTER CONT CONTINUOUS O.D. OUTSIDE DIAMETER OM OVERHEAD DBL DOUBLE DOJO DIAMETER PLCS PLACES D NAG DIAGONAL PLYWD PLYWOOD ON DOWN PROJ PROJECT DET DETAIL PROP PROPERTY DWG DRAWING PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH EA EACH PT PRESSURE TREATED EL ELEVATION ELEC ELECTRICAL RAD RADIUS EQ EQUAL REQ REQUIRED EQUIP EQUIPMENT RM ROOM E W EACH WAY RO ROUGH OPENING EXT EXTERIOR SCH SCHEDULE RN FINISH BHT SHEET FLUOR FLUORESCENT SIM SIMILAR FUR FLOOR SPEC SPECIFICATION F.S. FARSIDE SF SQUAREFOOT IFT FOOT SS STAINLESS STEEL STL STEEL GA GAUGE STRUCT STRUCTURAL GALV GALVANIZED STD STANDARD G.C. GENERALCONTRACTOR SOFT SQUAREFOOT GRND GROUND SO IN SQUARE INCH GYP BD GYPSUM WALL BOARD SUSP SUSPENDED HORZ HORVANTAL THK THICK HR HOUR THRU THROUGH HT HEIGHT TNNG TINNED HVAC HEATING VENTILATION T.O. TOP OF AIRCONDITIONING T O S. TOP OF STEEL TYP TYPICAL I.D. INSIDE DIAMETER IN INCH UNO UNLESS NOTED OTHERWISE INFO INFORMATION INSUL INSULATION VERT VERTICAL NT INTERIOR V I F� VERIFY IN FIELD IBC INTERNATIONAL BUILDING CODE w/ WITH LBS POUNDS W/O WITHOUT WP WATER PROOF R PLATE CHAIN -LINK FENCE WOOD FENCE fE CENTERLINE - T T - TELEPHONE (E) EXISTING - P P - POWER ___---------- GROUNDWIRE X DETAIL NUMBER WAX COAXIAL CABLE Xi SHEETNUMBER SPECIAL INSPECTIONS: SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2009 SECTION 1704. SOILWGEOTECHNIcAL: ❑SHORING INSTALLATION AND MONITORING []OBSERVE AND MONITOR EXCAVATION ❑VERIFY SOIL BEARING psi BEARING ❑SUBSURFACE DRAINAffE_ —PLACEMENT ❑VERIFY FILL MATERIAL AND COMPACTION ❑VERIFY CONDITIONS AS ANTICIPATED ❑PILE PLACEMENT (AUGER CASTIDRIVEN PILE) ❑OTHER REINFORCED CONCRETE: ❑REINFORCING STEEL AND CONCRETE PLACEMENT OPRESTRESSEDIPRECAST CONCRETE FABRICATION AND ERECTION ❑BATCH PLANT INSPECTION ❑SHOTCRETE ❑GROUTING ❑OTHER STRUCTURAL. STEEL: ❑FABRICATION AND SHOP WELDS ❑ERECTION AND FIELD WELDS AND BOLTING ❑OTHER STRUCTURAL ALUMINUM: ❑FABRICATION AND SHOP WELDS ❑ERECTION AND FIELD WELDS AND BOLTING ❑OTHER STRUCTURAL MASONRY: ❑CONTINUOUS ❑PERIODIC OTHER: NONE REQUIRED ANCHORING TO CONCRETE: []BOLTS INSTALLED IN CONCRETE ❑POSTANSTALLATION ADHESIVE ANCHORS ❑POST -INSTALLATION MECHANICAL ANCHORS T • Mobile•0 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 `PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: 4 &--pp NERSTONE . q ... N.. INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425 487 1732 FAX:425.4871734 EMAIL: cel@wmemt0n ngr.mm W W W.CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR: CCONSTRUCTION =REV:: DATE: =ISSUED FOR: SY:--I L DRAWN BY:-CHK.: APV.:" JRF DRA MWO CURRENT ISSUE DATE: L08-16-12 I INCMICI ICI=• _ �DRAWIN[i INf•VKMAIIUN: OO NOT SCALE DRAWINGS. CONTRACTOR MUSTWRIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF719S DRAWING ARE SUPERSEDED BY THE LATEST REVISION, THE INFORMATION CONTAINED IN THIS SET OF DOCUMENS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLEAT IS STRICTLY PROHIBRFD, DRAWING TITLE: GENERALNOTES DRAWING NUMBER: G-1 0 CEI JOB NUMBER: 12-06007 THIS IS NOT A SURVEY ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND ARE APPROXIMATE. (E) GRAVEL WALKWAY ACCESS (E) GRAVEL ACCESS RD - , 7 A•1.1 (E) ASPHALT PARKING LOT TL#:0721049017 SITE PLAN 22x3a SCALE: 1" =,W4r 11x17 SCALE: 1" -- 40'-C" [ ( [ ! I FRENCH LAKE PARK I TL#:0721049014 (E) T-MOBILE 141-0"x2(r-(r WOOD FENCE ENCLOSURE I (E) t150'-0" HIGH STEEL MONOPOLE WI PROPOSED REPLACEMENT & NEW ANTENNAS TMBXX-65184R2M �• _ �_� _ _ —_ PROPERTY LINE S88" 47' 53" E (t351.22') - - A-2 o a • Y .. (E) BUILDING (FIRE STATION) (E) CONCRETE SLAB - +r—.3 r o c� CIDI � LU Lu J zl1� IL TL#: 0721049210 IL IL I ±87,120 SQ. FT. (2.0 Ir EL U) ACRES) { I I I r k I �� i 1F (E)ASPHALT PARKING LOT PROPERTY LINE N88" 31' 43" E (t309.W) 1 r i I PLAN NORI 1 T • Mobile •® 19807 NORTHCREEK PKWY BOTHELL. WA 98011 OFFICE (425) 398-7600 REALC0M PLANS PREPARED BY: `E CUWJ EF43T0NE 15928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 96072 PHONE: 42SA871732 FAX:425.487.1734 EMAIL: wI@wmamIon"ngrwm W CORNERSTONE-ENGIR COM WW PROJECT INFO: S E04693A MIRROR LAKE / CINGULAR / KC FIRE 31617 1st AVENUE S FEDERAL WAY, WA98003 KING COUNTY ISSUED FOR: CCONSTRUCTION =REV:: DATE:=ISSUED FOR: BY:j OQ 05-11-12 CONSTRUCTION KID Qp 04-27-12 CLIENT REVIEW JRF L-DRAWN BY:—CHK.: APW JRF DRA MWO [LICENSURE-- CURRENT ISSUE DATE: 08-16-12 LDRAWING INFORMATION:' DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE aMSULTANT9 OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OFTHIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS Is PROPRIETARY BY NATURE ANY USE OR DMCLMUIIx E OTHER THAN WHICH L4 RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: SITE PLAN DRAWING NUMBER: A-1 0 CEI JOB NUMBER: 12-06007 NOTES: 1. CONTRACTOR TO PROVIDE ALL HANGERS & HARDWARE (STAINLESS STEEL &/OR GALVANIZED ONLY) TO SUPPORT CABLES & JUMPERS EVERY 3'-0". 2. RETURN USED LNNS & MCPA'S TO T-MOBILE WAREHOUSE. 3. PROPOSED 100AMP BREAKER IN VALARE POWER SHELF W/ (2) #2 THHN STRANDED IN EMT OR LT FLEX FROM BREAKER TO COVP. 4. CONTRACTOR TO REMOVE EXISTING RET HOME RUN COAX AND UNUSED GPS ANTENNA WITH CABLE. 5. CONTRACTOR TO MAINTAIN CLEARANCE FOR EXISTING CLIMBING PEGS WHEN INSTALLING RRH'S & NEW UNIVERSAL RING MOUNT. I W I (E) 100 GAL PROPANE TANK � r � r � I [CN J W I (E) T MOBILE OPEN AIR I W EQUIPMENT SHELTER (E)PROPANE NERATOR `II W W I� 1 I (E) GRAVEL ACCESS WALKWAY V� (E) CONCRETE SLAB I W/ UTILITY BOX I EXISTING ENLARGED SITE PLAN 22x34 SCALE: 1/2" = T-0" I 1 Tx17 SCALE: 114' = 1'-W 14,-0„ t7'-11„ (E) T-MOBILE LEASE AREA ALL 1 1 (E) RR65-19-02DP (GAMMA SECTOR; 350" AZIMUTH), TYP. TO BE REMOVED &REPLACED F(E) (E) TMATO REMAIN (2 PER SECTOR, TOTAL OF 6) ,(E) t150'-0" HIGH STEEL MONOPOLE (E)LANDSCAPI NG (TYP) VICE LIGHT LITIES ED TO WALL -am Ol 1 , 0 Ile f (E) MCPA CABINET zm (E) NOKIA ULTRASITE ' CABINET ffi (E) NOKIII ' ULTRASITE { `k, >: � � ;;', �ti , ^r•{ ,; }.� . , � ; {�\�C CABINET _ I (E) T-MOBILE ICE BRIDGE W/ (12) 7/8"0 COAX (E) RR65-19-02DP (BETA SECTOR; 240' AZIMUTH), TYP. TO BE REMOVED & REPLACED 0 (E) RR65-19-02DP (ALPHA SECTOR; 120' AZIMUTH), TYP- TO BE REMOVED & (E) OTHER (CARRIER EQUIPMENT SHELTER - I / i (E) 6'-0- HIGH CHAIN -LINK FENCE W/ BARB WIRE (TYP) (E) CHAIN -LINK FENCE 4 PLAN NORI T • Mobile•® 19807 NORTH CREEK FKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 [ PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: C-1:Cpl"1►+lEirLL3TGNE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE. WA 96072 PHONE: 425487.1732 FAX:425.4B71734 EMAIL: wi@mmGmtcn ngr.mm W W W.CORNERSTONE-ENGR.COM .,PROJECT INFO: SE04693A MIRROR LAKE / CINGULAR / KC FIRE 31617 1st AVENUE S FEDERAL WAY, WA 98003 KING COUNTY ~ ISSUED FOR CCONSTRUCTION ,REV:' FOR: BY: Qp 05-11-12 CONSTRUCTION KID Al04-27-12 CLIENT REVIEW JRF DRAWN BY:=CHK.: APV.: 11 JRF I DRA 1 MW-071 CCURRENT ISSUE DATE: 08-16-12 =LICENSURE: 4 cF ry0;r 4h DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORSANOOMISSIONS ALLPREVIOUS ESSUESOF THIS DRAWING ARE SUPERSE DED BY THE LATEST REVISI ON. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: EXISTING ENLARGED SITE PLAN —nRAW[NC, NUMBER:. - A-1.1 0 CEI JOB NUMBER: 12-06007 \V \V w NOTES: 1. CONTRACTOR TO PROVIDE ALL HANGERS & HARDWARE (STAINLESS STEEL WOR GALVANIZED ONLY) TO SUPPORT CABLES & JUMPERS EVERY 3'-0". 2. RETURN USED LNA'S & MCPA'S TO T-MOBILE WAREHOUSE. 3. PROPOSED 100AMP BREAKER IN VALARE POWER SHELF W/ (2) #2 THHN STRANDED IN EMT OR LT FLEX FROM BREAKER TO COVP. 4. CONTRACTOR TO REMOVE EXISTING RET HOME RUN COAX AND UNUSED GPS ANTENNA WITH CABLE. 5. CONTRACTOR TO MAINTAIN CLEARANCE FOR EXISTING CLIMBING PEGS WHEN INSTALLING RRH'S & NEW UNIVERSAL RING MOUNT. I I I _ `I, f I (E) 100 GAL PROPANC TANK ( PROPOSED (1) HIGH CAPACITY W COVP'S MOUNTED TO BACK OF ..>- CABINET. j1 (E) NOKIA ULTRASITE A3�' \ �I v J i�•1 J W FL I MOBILE (E) T OPEN NR EQUIPMENT SHELTER W I W (E) PROPANE GENERATOR iliz I I GRAVEL A ACCESS WALKWAY I ' �V (E) CONCRETE SLAB ( W/ UTILITY BOX I I / �I I `I PROPOSED ENLARGED SITE PLAN 22x34 SCALE: 1/2" = V-0' I 11x17 SCALE: 1/4" = T-T 14,-0„ tT-11" (E) T-MOBILE LEASE AREA 3 t I I 0 I F(E)CE LIGHTES TO WALL W PROPOSED NEW PANEL ANTENNA TMBXX-6516-R2M F - (GAMMA SECTOR; 350° AZIMUTH) (- 6 1 V/ PROPOSED REPLACEMENT ANTENNA TMBXX-6516-R2M TO REPLACE (E) ANTENNA (GAMMA SECTOR; 350' AZIMUTH), TYP +' S (E) TM`AIT/O REMAIN (2 PER SECTOR, TOTAL OF \6) W � W (E) t150'-0" HIGH STEEL MONOPOLE (E)LANDSCAPING (TYP) \�/ I \�/I 2as� (E) MCPA CABINET r I pROPO$f=D UNIVERSAL RING Q MOUNT W/ STANDOFF ARM A-3.1 r� (E) NOKIA ULTRASITE PROPOSED (1) FRIG MOUNTED 1 ' CABINET TO (E) NEW ANTENNA PIPE 11 MAST @ EACH SECTOR A-3 A.�c; .,�:r:;,.:.:: •: _ '�; h• \''�'�� tit �f� .�� (E) NOKIA v j Cf (: ''. `� j PROPOSED NEW PANEL ULTRASITE vrti\/ ,;' ANTENNA TMBXX-6516-R2M 6 ' CABINET ^ n { (ALPHA SECTOR; 120° AZIMUTH) PROPOSED REPLACEMENT ANTENNA (E) T-MOBILE ICE BRIDGE WI(12) 7/6"OI COAX I - (E) & PROPOSED (1) HIGH CAPACITY HYBRID (ALPHA SECTOR; TO REPLACE ), ANTENNA CABLE ROUTED TO MATCH (E) COAX 9 {ALPHA SECTOR; 120° AZIMUTH), TYP �1 A-3 -RF-i= I I I PROPOSED (1) HIGH CAPACITY COVP'S MOUNTED TO PROPOSED 1 UNIVERSAL RING MOUNT A-3 (E) OTHER CARRIER EQUIPMENT SHELTER PROPOSED NEW PANEL ANTENNA TMBXX-6516-R2M (BETA SECTOR; 240° AZIMUTH] R�1 (E) 6'-0" HIGH CHAIN -LINK FENCE W/ BARB WIRE (TYP) PROPOSED (2) FXFB'S (REMOTE RADIO UNITS), 7 MOUNTED TO PROPOSED UNIVERSAL RING MOUNT A3 (E) CHAIN -LINK FENCE j PROPOSED REPLACEMENT ANTENNA TMBXX-6516-R2M TO REPLACE (E) ANTENNA 6 (BETA SECTOR; 240° AZIMUTH), TYP RF-1 �V PLAN NORTF 1 T • Mobile-' 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 9BO72 PHONE: 425487.1732 FAX: 425.487.1734 EMAIL: mQmmemton ngr.mm W W W.CORNERSTONE-ENGR.COM PROJECTINFO L-ISSUED FOR CCONSTRUCTION =REV:-DATE:=ISSUED FOR: BY:� OQ 05-11-12 CONSTRUCTION KIO Qp 04-27-12 CLIENT REVIEW JRF '--DRAWN BY:=CHK.: APV.: JRF DRA MWO I -CURRENT ISSUE DATE: 08-16-12 LICENSURE: DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALLDIMENSIONS AND ADVISE CONSULTANTS OFANY ERRORS AND OMGSiONS. ALL PREVIOUS ISSUES OF THIS ORAWING ARE SUPERSE DED BY THE LAYEST REV15EON. THE WFORMATION CONTAINED IN 7H15 SET OF DOCUMEIMS IS PROPRIETARYBY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELAYED TO NAMED CLIEWNS STRICTLY PROHIBITED - DRAWING TITLE: PROPOSED ENLARGED SITE PLAN DRAWING NUMBER: A-1.2 0 CEI JOB NUMBER: 12-06007 ■ �T.O.;EI MONOPOLE ■ EL ±150'-0" AGL (E) OTHER CARRIER ANTENNA ARRAY PROPOSED (1) HIGH CAPACITY COVP MOUNTED 4 TO PROPOSED UNIVERSAL RING MOUNT (E) TMA TO REMAIN (2 PER SECTOR, TOTAL OF 6) RA�D CENTER OF PROPOSED PANEL ANTENNAS Y EL 116'0" AGL - PROPOSED ANTENNA PIPE MAST TO MATCH (E) CUT LENGTH TO SUIT (1 PER SECTOR, TOTAL OF 3) 1 , PROPOSED UNIVERSAL RING MOUNT W1 STANDOFF ARM A 3.1 (E) T-MOBILE ICE BRIDGE W1(12) 718"0 COAX & PROPOSED (1) HIGH CAPACITY HYBRID CABLE ROUTED UP (E) MONOPOLE TO MATCH (E) COAX (E) T-MOBILE SITE SUPPORT CABINETS, BEYOND - (E) T-MOBILE OPEN-AIR EQUIPMENT SHELTER - GRADE SOUTH ELEVATION F-,,INT NOTE: ALL PROPOSED ANTENNASfEGUIPMENT & ATTACHMENTS SHALL BE PAINTED TO MATCH EXISTING ON -SITE CONDITIONS. (E) OTHER CARRIER MW DISH PROPOSED (2) FXFB'S (REMOTE RADIO UNITS), MOUNTED TO PROPOSED T UNIVERSAL RING MOUNT A3 .I PROPOSED (1) FRIG MOUNTED @ ANTENNA PIPE MAST (1 PER 11 SECTOR, TOTAL OF 3) A� PROPOSED REPLACEMENT & NEW PANEL ANTENNA TMBXX-6516-R2M 6 (3 PER SECTOR, TOTAL OF 9) R �. (E) OTHER CARRIER ANTENNA ARRAY (E)±150'-0" HIGH STEEL MONOPOLE (E) OTHER CARRIER ANTENNA ARRAY PROPOSED (2) FXFB UNIT MOUNTED TO PIPE MAST NOTE: CONTRACTOR TO MAINTAIN CLEARANCE FOR EXISTING CLIMBING PEGS WHEN INSTALLING RRH'S & NEW UNIVERSAL RING MOUNT PROPOSED (1) HIGH CAPACITY COVP MOUNTED TO PIPE MASI ENLARGED DETAIL 22x34 SCALE: 1f2" = 1'-0` (E) 6'-0" HIGH CHAIN -LINK FENCE Wl BARB WIRE (E) OTHER CARRIER EQUIPMENT SHELTER 11x17 SCALE: 114" = 1'-0" PROPOSED UNIVERSAL RING MOUNT � WI STANDOFF ARM MOUNTED ! ' l DIRECTLY ABOVE (E) ANTENNA MOUNT A3.1 T • Mobile•® 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-760D =PROJECT CONSULTANTS: REALC0M =PLANS PREPARED BY: Ce Ca;7NE'?l3TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA98072 PHONE: 425.487.1732 FAX:425.487.1734 EMAIL: mQwmemlor n9r.wm WWW CORNERSTONE-ENGR.COM '.PROJECT INFO: L ISSUED FOR' CI CONSTRUCTION71 "REV.=DATE:�ISSUED FOR: BY:= Qp 05-11-12 CONSTRUCTION KIO QA 04-27-12 CLIENT REVIEW JRF =DRAWN BY:=CHK.: APV.; JRF DRA MWO CURRENT ISSUE DATE: 08-16-12 771 —1 IC`�NC11RF- ,SL ." r°fn �►�'+onwt �[iOL� 1� DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED =DRAWING TITLE: SOUTH ELEVATION =DRAWING NUMBER: A-2 0 CEI JOB NUMBER: 12-06007 22x34 SCALE: 118" = V-W 111x17 SCALE' 1116" = V-0" PAINT NOTE: T.O. IE) MONOPOLE ALL PROPOSED ANTENNAS/EQUIPMENT & ATTACHMENTS SHALL BE PAINTED TO AV EL t150'-0" AGL MATCH EXISTING ON -SITE CONDITIONS. (E) OTHER CARRIER MW DISH (E) OTHER ER AN EN A ARRAY PROPOSED (1) HIGH CAPACITY COVP (1) FRIG MOUNTED TO PROPOSED PROPOSED 7 MOUNTED (ANTENNA UNIVERSAL RING MOUNT p. PIPE MAST (1 PER 1 (E) TMA TO REMAIN (2 PER SECTOR, TOTAL OF 3) A-3 ` r SECTOR, TOTAL OF 6) RAD CENTER OF PROPOSEDPANEL EL I18'-0" AGLNAS 41 1 I� PROPOSED ANTENNA PIPE MAST , TO MATCH (E) CUT LENGTH TO SUIT (1 PER SECTOR, TOTAL OF 3) PROPOSED REPLACEMENT & NEW PROPOSED UNIVERSAL RING PANEL ANTENNA TMBXX 6516-R2M MOUNT W/ STANDOFF ARM 1 A (3 PER SECTOR, TOTAL OF 9) , 6 RP-1 (E) OTHER CARRIER ANTENNA ARRAY (E) t150'-0" HIGH STEEL MONOPOLE (E) OTHER CARRIER ANTENNA ARRAY (E) T-MOBILE ICE BRIDGE W/ (12) 7/8"0 COAX & PROPOSED (1) HIGH CAPACITY HYBRID CABLE ROUTED UP (E) MONOPOLE TO MATCH (E) COAX (E) 6-0" HIGH CHAIN -LINK ' I I ` (E) T-MOBILE OPEN-AIR FENCE W/ BARB WIRE I EQUIPMENT SHELTER (E) OTHER CARRIER + EQUIPMENT SHELTER 1r (E) T-MOBILE SITE SUPPORT CABINETS, GRADE (REF) + BEYOND T.O. (E) MONOPOLE Aw EL t150'-O" AGL (E) OTHER CARRIER MW DISH — (E) OTHER CARRIER ANTENNA ARRAY PROPOSED (2) FXFB'S (REMOTE RADIO UNITS), MOUNTED TO PROPOSED UNIVERSAL RING MOUNT (E) TMA TO REMAIN (2 PER SECTOR, TOTAL OF 6) .- RAD CENTER OF PROPOSED jk PANEL ANTENNAS EL 118'-0" AGL PROPOSED ANTENNA PIPE MAST TO MATCH (E) CUT LENGTH TO SUIT (1 PER SECTOR, TOTAL OF 3) PROPOSED UNIVERSAL RING MOUNT W/ STANDOFF ARM (E) OTHER CARRIER EQUIPMENT SHELTER GRADE PAINT NOTE: ALL PROPOSED ANTENNAS/EQUIPMENT & ATTACHMENTS SHALL BE PAINTED TO MATCH EXISTING ON -SITE CONDITIONS. PROPOSED (1) FRIG MOUNTED @ ANTENNA PIPE MAST (1 PER 11 SECTOR, TOTAL OF 3) A� PROPOSED REPLACEMENT & NEW PANEL ANTENNA TMBXX-6516-R2M (3 PER SECTOR, TOTAL OF 9) Li RF-1 (E) OTHER CARRIER ANTENNA ARRAY (E) t150'-0" HIGH STEEL MONOPOLE (E) OTHER CARRIER ANTENNA ARRAY NORTH ELEVATION 1 3 EAST ELEVATION 2 22x34 SCALE: 1 /8" = 1'-0" 111 xi SCALE: 1116" = V-0" I 2x34 SCALE: 1 /8" = V-0" I Ixl7 SCALE: 1 /16" = T-W I— PAINT NOTE: T.O. [E] MONOPOLE ALL PROPOSED ANTENNAS/EQUIPMENT 51, & ATTACHMENTS SHALL BE PAINED TO EL t150'-0" AGL MATCH EXISTING ON -SITE CONDITIONS. (E) OTHER CARRIER MW DISH (E) OTHER CARRIER ANTENNA ARRAY — —_ d Il it PROPOSED (1) HIGH CAPACITY COVP MOUNTED TO PROPOSED UNIVERSAL RING MOUNT PROPOSED (1) FRIG MOUNTED @ ANTENNA PIPE MAST (1 PER R 1 SECTOR, TOTAL OF 3) a RAD CENTER OF PROPOSED PANEL ANTENNAS _ EL 118'-0" AGL PROPOSED ANTENNA PIPE MAST TO MATCH (E) CUT LENGTH TO SUIT (1 PER SECTOR, TOTAL OF 3) PROPOSED UNIVERSAL RING MOUNT W/ STANDOFF ARM (E) T-M OBI LE OPEN-AIR EQUIPMENT SHELTER - GRADE WEST ELEVATION 22x34 SCALE: 118" = V-0" i 1 x17 PROPOSED (2) FXFB'S (REMOTE RADIO UNITS), MOUNTED TO PROPOSED UNIVERSAL RING MOUNT( 7 •1 Aa) (E) TMA TO REMAIN (2 PER SECTOR, TOTAL OF 6) PROPOSED REPLACEMENT & NEW PANEL ANTENNA TMBXX-6516-R2M (3 PER SECTOR, TOTAL OF 9) . 6 RF-1 ` (E) OTHER CARRIER ANTENNA ARRAY (E) t150'-0" HIGH STEEL MONOPOLE (E) OTHER CARRIER ANTENNA ARRAY (E) T-MOBILE SITE SUPPORT CABINETS, BEYOND 1 T • Mobile " QD 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 ~PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: �E CdFiNEFR 6T0NE 16928 WOODINVILLE-REDMOND RD NE, SURE 210 WOODINVILLE, WA 98072 PHONE: 425487.1732 FAX:425487.1734 EMAIL; ceI@wmemlceeangrwm W W W.CORNERSTONE-ENGR.COM —PROJECT INFO: ISSUED FOR: CCONSTRUCTION r"REV.=DATE:—ISSUED FOR: BY:� DRAWN BY:=CHK.: APV.: JRF I DRA MWO CURRENT ISSUE DATE: 11 08-16-12 qmo,( v DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL D IMENSION S AND ADVISE OONSUILTANYS 0 F ANY ERRORS AND OMI SSIONS. ALL PREYIOIFS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY 8Y NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH 15 RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: NORTH, EAST & WEST ELEVATIONS DRAWING NUMBER: A-2.1 0 CEI JOB NUMBER: 12-06007 6" =1,4r opm,w TOP O O 00 FRONT NOKIA FRIG RRH 22x34 SCALE: 3"=1'-0' Ilixil SCALE: 1 1/2" = 111 W RxO 4 ANT 4 RX ANT 5 TX/RX _ RxO 5 RxO 3 ANT 6RX ANT TYJRX PWR IN RxO 6 LED FAN/TX OFF STATUS LED MODULE STATUS — GROUNDING POINTS OPT 1--/ OPT 2- EAC OPT 3 1'-5 518" NOKIA FXFB RRH MODEL #472166A 22x34 SCALE: 3" = 1'-0" 111x17 SCALE: 1 112" = V-0" i o 0 0 0 fsw++ewrww +rrrr r�. FRIE RRU (TOWER MOUNTED) J RIGHT SIDE ANT 2 RX RxO 2 RxO 1 ANT 1 TX/RX RET (FXFB ONLY) i NOTE: FOR MOUNTING SEE DETAIL 2/A-3.1 11 PROPERTY VALUE HEIGHT 133 mm/3U (5.2 in) WIDTH WIDTH 447 mm 17.6 in) (WITH COVERS) 490 mm (19.3 in) DEPTH (FOR RACK 395 mm (15.6 in) ASSEMBLIES) DEPTH 560 mm (22 in) (WITH COVERS) WEIGHT (INCLUDING THE CORE, FANS MAX. 25 kg (55.1 lb) AND CASING) NOTE: FOR MOUNTING SEE DETAIL 2/A-3.1 _ 3 11116" I GROUNDING HARDWARE TOP 7-16 DIN MALE 7-16 DIN MALE GROUNDING HARDWARE WEATHERPROOF ASIG INPUT CONNECTOR — 7-16 DIN FEMALE --r (18) FIBER INDOORIOUTDOOR DISTRIBUTION CABLE DIELECTRIC CENTRAL MEMBER (2) #18 AWG COPPER PAIR (10) #6 AWG THHNrrHWN COPPER CONDUCTOR (2) ARAM ID RIPCORDS CORRUGATED LAMINATED STEEL TAPE MDPE OUTER JACKET FRONT SIDE BIAS TEE 1 o HIGH CAPACITY HYBRID CABLE 22x34 SCALE: 6" = V-0" 11x17 SCALE: 3" = T-0" 22x34 SCALE: NTS 111x17 SCALE: NTS COVP MOUNTING FRAME , f- ALARM OVP CONNECTION rf 1/4"0 GALV BOLT % (TYP OF 8 PER COVP FIBER PANEL MOUNTING BRACKET) MAIN GROUND f 18 2I0-14AWG SM ADAPTERS PIPE ® ®�" c T U-BOLT RETURN 15 CONNECTIONS 2/0 - 14 AWG GROUNDBAR 4-14AWG — 48-15 CONNECTIONS 2/0 - 14 AWG 7 HIGH CAPACITY COVP INTERIOR 22x34 SCALE: 1 1/2" = 1'-0" I 11x17 SCALE: 3/4" = T-O" PROPERTY 3-SECTOR RF MODULE DUAL RF MODULE SINGLE RF MODULE HEIGHT 133 mm/3U (5.2 in) 133 mm/3U (5.2 in) 133 mm/3U (5.2 in) WIDTH 447 mm (17.6 in) 447 mm (17.6 in) 447 mm (17.6 in) WIDTH (WITH COVERS) 490 mm (19.3 in) 490 mm (19.3 in) 490 mm (19.3 in) DEPTH (FOR RACK mm 395 mm in) 395 mm 15.6 in ( ) ASSEMBLIES) DEPTH (22 i) 560 mm (22 in) 56 (22 i 560 mm (22 in) 560 mm (22 in) (WITH COVERS) WEIGHT (INCLUDING THE 25 kg (55.1 lb) 21.8 kg (48.1 lb) 18.7 kg (41.2lb) CORE, FANS AND CASING) ^r RIGHT SIDE ED M LN NOTE: FOR MOUNTING SEE DETAIL 2/A-3.1 NOKIA FRIA RRH 3 22x34 SCALE: 1 V2" = 11-0" 11X17 SCALE: 3/4"= T-0" 1'-5 13/16" 1'-4 1 /B" FRONT HIGH CAPACITY RAYCAP COVP 22x34 SCALE: 1 1!2" = T-0" I 1 Ix17 SCALE: 314- = 1'-0" L 1/4"0 GALV BOLT (TYP OF 4 PER COVP) COVP RIGHT SIDE TOP 6 COVP MOUNT 2204 SCALE: 1 1/2" = 1'-0" 7" 5 13/16" RIGHT SIDE T • •Mobile•® 19807 NORTH CREEK PKWY BOTHELL. WA 98011 OFFICE (425) 398-7600 PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: � r G+Sr'TlJ Fr ! TONE 16926 WOODINVILLE-REDMOND RD NE, SUnE 210 W OODINVILLE, WA 98072 PHONE: 4254071732 FAX:425.487.1734 EMAIL: mi@wmemlone-ergrwm W W W CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR: CCONSTRUCTION ,REV:'DATE:=ISSUED FOR: BY:::� Q05-11-12 CONSTRUCTION KID QA 04-27-12 CLIENT REVIEW JRF DRAWN BY:=CHK.: APV.: JRF DRA MWO CURRENT ISSUE DATE: 5 L..�r..�..� . 08-16-12 NOTE: FOR MOUNTING SEE DETAIL 5/A-3 HYBRID TRUNK IN POWER & FIBER JUMPER OUT (TYP) 7/8" BOTTOM urc�9vlrvu IrvrVRIVH11V1V. DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBRED. DRAWING TITLE: F- DETAIL SHEET DRAWING NUMBER: A-3 0 1 CEI JOB NUMBER: 12-06007 �t PARTS LIST ITEM # QUANTITY PART NUMBER DESCRIPTION 1 2 601257 ANGLE ARM 2 2 601256 MOUNTING CLAMP 3 2 601235-1 BRACKET 4 2 601235-2 BRACKET 5 1 601258 LABEL, ANGLE 6 4 600679-3 SPACER TUBE 7 14 100525-24 ME FLAT WASHER (STAINLESS STEEL) 8 2 600419-8 M8x1.25x25mm LARGE CARRIAGE BOLT (STAINLESS STEEL) 9 6 6/1/7395 M8 LOCK WASHER (STAINLESS STEEL) 10 4 600419-10 M8x1.25x110mm LARGE HEX HEAD SCREW (STAINLESS STEEL) 11 6 204001-15 M8x1.25 HEX NUT (STAINLESS STEEL) 12 2 225244 CLAMP PLATE 13 8 600419-24 LARGE LOCK WASHER (STAINLESS STEEL) 14 8 204001-21 M12x1.75 HEX NUT (STAINLESS STEEL) 15 4 600419-12 M12x1.75x150mm LARGE CARRIAGE BOLT (STAINLESS STEEL) 17 1 601584 MOLYBDENUM DISULFIDE GREASE BOTTOM BRACKET 1 a 7 TOP BRACKET ANTENNA BRACKET ATTACHMENT 22x34 SCALE: NTS 111 xi SCALE: NTS FRONT RIGHT SIDE MOUNTING PLINTH (FMF 22x34 SCALE: 1 112" = V-0" 111x17 SCA U-BOLT MOUNT LOCATION (TYP OF 2) FPKAIJ-BOLT MOUNT LOCATION (TYP OF 2) FLOOR MOUNT LOCATION (TYP OF 6) - FPKA MOUNTING BRACKET NOT USED 22x34 SCALE: NTS c 3" STD WT PIPE I11x17 SCALE: NTS ANTENNA 7 ANTENNA ATTACHMENT 22x34 SCALE: NTS Tilx17 SCALE: NTS 3" STD WT PIPE 3 FPKA MOUNTING BRACKET " 4 FMFA MOUNTING PLINTH RF MODULE M8x120 BOLT M10x120x105mm BOLT FMFA FIXING POINTS MOUNTING BRACKET (FPKA = V-0" I 22x34 SCALE: NTS I 11x17 SCALE: NTS I 3 RRH MOUNTING 22x34 SCALE: NTS 11x17 SCALE: RF MODULE 10 1 NOT USED 22x34 SCALE: NTS 6 1NOT USED 22x34 SCALE: NTS 11x17 SCALE: NTS 11x17 SCALE: 0 kl II III II QUAD UNIVERSAL RING MOUNT (VALMONT #852361) 8" STANDOFF ARM FOR SINGLE ANTENNA (VALMONT gMM01) � .F. 3"STDWTxM'PIPE I 21 UNIVERSAL RING MOUNT 22x34 SCALE: NTS I 11x17SCALE: NTS 0 5 1 T Mobile - 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 398-7600 PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: Ce)-Ff NEERSIrONE N—RING. INC 16928 WOODINVILLE-REDMOND RD NE, SURE 210 WOODINVILLE, WA 98072 PHONE: 425A87.1732 FAx:425.4871734 EMAIL: ml@wmemlaa 119.mm W W W CORNERSTONE-ENGR COM , PROJECT INFO: ISSUED FOR: CLCONSTRUCTION rREV.:DATE:=ISSUED FOR: BY:=— Q05-11-12 CONSTRUCTION KID A 04-27-12 CLIENT REVIEW JRF :DRAWN BY:=CHK.: APW JRF DRA MWO =CURRENT ISSUE DATE: 08-16-12 = LICENSURE: w DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFoRu&TION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED DRAWING TITLE: DETAIL SHEET =DRAWING NUMBER: A-3.1 0 CEI JOB NUMBER: 12-06007 (2) 3/8"0 SS HEXNUT RRH CHASSIS (#2) TWO HOLE COMPRESSION LUG GROUND WIRE STUD (TYP NO -LUX ANTI -OXIDIZING OF 2 @ FRONT AND BACK COMPOUND OF CABINET) CLEAR HEAT SHRINK ON COMPRESSION LUGS 3/8"0 STAR WASHER - #2 STRANDED GREEN INSULATED COPPER GROUND LEAD TO BUSS BAR OR #2 SOLID BARE TINNED COPPER PLAN TO GROUND RING NOTE: FOR GROUNDING CONNECTIONS TO PAINTED CABINETS CHASSIS, GRIND OFF ALL ENAMEL COATINGS TO BARE METAL AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE METAL. #2 GREEN INSULATED COPPER WIRE TO AGB AT TOP OF POLE COAX CABLE GROUNDING KITS WITH LONG BARREL COMPRESSION LUGS, INSTALLED BY CONTRACTOR HARGER GROUNDING BAR #GB14824 (OR EQUAL) WITH HOLE PATTERN, STANDOFF INSULATORS AND MOUNTING BRACKETS AS SHOWN #2 SOLID BARE TINNED COPPER WIRE TO GROUND RING - PROVIDE (2) PER MGB ® = CADWELD GROUND ATTACHMENT 112 TYPICAL MASTER GROUND BAR 22x34 SCALE: NTS 111x17 SCALE: NTS I 22x34 SCALE: NTS 11x17 SCALE: NTS NOTE: GROUND HYBRID CABLE TOP & BOTTOM USING UNIVERSAL 1 5/8" GROUNDING STRAP, PART#252172 SCHEMATIC GROUNDING PLAN HARGER GROUNDING BAR #GBI14412G COAX CABLE, COVP & RRU GROUNDING KITS #2 GREEN INSULATED COPPER WIRE TO MGB AT BOTTOM OF POLE - 11 ACCESSORY GROUND BUSS BAR 22x34 SCALE: NTS 111x17 SCALE: NTS (E) GROUND ACCESSORY BUSS BAR, TYP. f 2 ] (E) ANTENNA MOUNT STRUCTURE. PROPOSED #2 STRANDED GREEN INSULATED COPPER GROUND LEAD, TYP. (E) #2 STRANDED GREEN INSULATED COPPER GROUND LEAD, TYP. (V.I.F.) C 5 } PROPOSED GROUND CONNECTION TO RRH. SEE DETAIL 12 KEYED NOTES 22x34 SCALE: NTS 111x17 SCALE: NTS SYMBOL I DESCRIPTION MASTER GROUND BAR 1/4"x4"x24" COPPER ACCESSORY GROUND BAR 1/4"x4"x12" OR S 1/4"x4"x20" COPPER ttTYPE GIR NOTE: CADWELD "TYPES" SHOWN ABOVE ARE EXAMPLES - CONSULT WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED FOR THIS PROJECT- 10 CADWELD CONNECTIONS 9 22x34 SCALE: NTS 111x17 SCALE: NTS 1. GROUNDING SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. 2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS 8". 3. NO SPLICES PERMITTED IN GROUND CONDUCTORS. 4, ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. USE PENETROX OR EQUIVALENT ANTIOXIDANT GREASE. 5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR WILL BE PERMITTED. 6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED VALUES. 7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY AT LEAST 6". 8. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A RESISTANCE OF 5 OHMS TO EARTH. 9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL OBJECTS OR SUPPORTS; TO PRECLUDE ESTABLISHING A "CHOKE" POINT. 10. GROUND BARS SHALL NOT BE FIELD MODIFIED. 6 11. GROUND RING BURIAL DEPTH SHALL BE 30", O GROUND INSPECTION WELL ® 5/8"xV-0" COPPER CLAD STEEL GROUND ROD ® COMPRESSION LUG/MECHANICAL CONNECTION ® CADWELD CONNECTION ® SIDE SPLICE CADWELD FIELD VERIFY & TIE INTO EXISTING GROUNDING PLAN NORTH 12. A CERTIFIED CONTRACTOR WILL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE GROUNDING SYSTEM USING A MEGGER OR EQUIVALENT. THE ACCEPTABLE RESISTANCE MEASURED FOR THE GROUNDING SYSTEM WILL NOT EXCEED 5 OHMS RESISTANCE. THREE DISTANCES SHALL BE USED: 1 AT 100 FEET, 1 AT 70 FEET, AND 1 AT 35 FEET. THESE DISTANCES ARE SUBJECT TO A SITE BY SITE BASIS. T-MOBILE-WTS SHALL BE GIVEN 24 HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND TESTING WILL BE AT THE EXPENSE OF THE CONTRACTOR. 3 1 LEGEND 1 2 GROUNDING NOTES 1 1 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS T Mobile•® 19807 NORTH CREEK PKWY BOTHELL, WA 98011 OFFICE (425) 399-7600 `PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: EE C:0391VEIr19TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE. WA 98072 PHONE: 425AB71732 FAX:425.4871734 EMAIL:-i@wmelsla "n9rm W W W.CORNERSTONE-ENGR COM r-PROJECT INFO: SE04693A MIRROR LAKE / CINGULAR / KC FIRE 31617 1st AVENUE S FEDERAL WAY, WA98003 KING COUNTY ISSUED FOR: CCONSTRUCTION r REV:- DATE: =ISSUED FOR: BY:= DRAWN BY:=CHK.: APV.:' JRF ORA MWO [[I CURRENT ISSUE DATE: 08-16-12 If_r7m" "', o ISO (lt- =DRAWING INFORMATION: DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE, ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED =DRAWING TITLE: SCHEMATIC GROUNDING PLAN 8 DETAILS =DRAWING NUMBER: E-1 0 CEI JOB NUMBER: 12-06007 22x34 SCALE: 3/4" = V-0" 111x17 SCALE: 3/8" = 1'-0" RF DATA SHEET SECTOR COLOR # OF ANTENNAS ANTENNA VENDOR ANTENNA MODEL AZIMUTH (TN) MECHANICAL DOWNTILT ELECTRICAL DOWNTILT RAD CENTER HYBRID CABLE LENGTH COAX CABLE LENGTH ALPHA (S-1) RED 3 ANDREW TMBXX-6516-R2M 120° TBD TBD 118'-0" AGL 130' N/A BETA (S-2) GREEN 3 ANDREW TMBXX-6516-R2M 240° TBD TBD 118'-0" AGL GAMMA (S-3) YELLOW 3 ANDREW TMBXX-6516•R2M 350° TBD TBD 116'-0" AGL UL & DL FREQUENCIES: SEATTLE MARKET: PCs: UL: 1885 - 1895 Mhz, 1900 -1905 Mhz DL: 1965 - 1975 Mhz, 1980 -1985 Mhz AWS: UL: 1745 - 1755 Mhz, 1730 -1735 Mhz DL: 2145 - 2155 Mhz, 2130 - 2135 Mhz RF DATA SHEET 22x34 SCALE: NTS lllxl7 COAXIAL CABLE NOTES: 1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED. 2. CONTRACTOR TO PROVIDE DRIP LOOPS IN CABLES AND JUMPERS WHERE NECESSARY. 3. TAGGING: 3.1 ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. 3.2 COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING). 4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0" ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. 11 1 f.I ,- CONNECTORS J+ STEP 1 2" 2" I� ELECTRICAL TAPE BUTYL TAPEF(ALSOOWN(1 LAYER) AS MASTIC, PE) STEP 2 4" ELECTRICAL TAPE: 3 LAYERS WITH 2" TAPE AND 3 LAYERS IN 3/4" TAPE (ALL WITH MINIMUM 50% OVERLAP). ALL TAPE ENDS SHALL BE CUT (DO NOT COAT WITH 3M SCOTCH COTE SPRAY SEALER. — STEP 3 NOTE: 4" VERTICAL CONNECTIONS SHALL BE I TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY FROM CONNECTION, TYP. PROVIDE HEAT SHRINK IN PLACE OF I —I TAPE FOR QUAD POLES AND LNA's (TYP.) STEP 4 COAXIAL CABLE WEATHERPROOFING 22x34 SCALE: NTS 111x17 SCALE: NTS 3 11 15/16" FRONT a TOP SEA fOR 1, 2 & 3 (9) TMBXX-6516-R2M QUAD ANTENNAS (5) MODULES (2 FXFB + 3 FRIG) (1) HYBRID CABLE & (2) COVP KEEP ALL EXISTING TMA'S KEEP ALL COAX SIDE ISOMETRIC PROJECT SUMMARY 22x34 SCALE: NTS lllxl7 ANDREW TMBXX-6516-R2M ANTENNA MECHANICAL SPECIFICATIONS PART NUMBER I HEIGHT WIDTH IDEPTH WEIGHT TMBXX-6516-R2M 591n (wish anuator) 111.9in 163in 134.6Ibs CONNECTORS STANDARD MOUNTING HARDWARE 2) 7-16 DIN INCLUDED ELECTRICAL SPECIFICATIONS FREQUENCY I POLARIZATION GAIN AZIMUTH B.W. ELEVATION B.W. 1710-2155 MHz ±45° 17.5° t 0.8 64.5° t 8 7.2° t 1.2 VSWR I MAX INPUT POWER 1.35:1 / 16.5 1250 WATTS 1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY T-MOBILE AND INSTALLED BY CONTRACTOR. 2. COAX COLOR CODING: ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER FROM TRUE NORTH AND COLOR CODED TO ESTABLISHED T-MOBILE STANDARDS. T - -Mobile 19807 NORTH CREEK PXWY BOTHELL, WA 98011 OFFICE (425) 398-7600 PROJECT CONSULTANTS: REALC0M PLANS PREPARED BY: �E COi�W6PLETONE 16928 WOODINVILLEaREDMOND RD NE. SURE 210 WOODINVILLE, WA 98072 PHONE: 425AB7.1732 FAX:425487.1734 EMAIL: wi@--mtom -91mm W W W CORNERSTONE-ENGR COM PROJECT INFO: 9 SE04693A MIRROR LAKE / CINGULAR / KC FIRE 31617 1 st AVENUE S FEDERAL WAY, WA98003 KING COUNTY 3. COAX COLOR CODING APPLIES TO SECTORIZED SITES. FOR OMNI SITES, USE THE ATO, BTO & GTO COLOR CODES ONLY. 4. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1" WIDE WEATHER PROOF COLORED VINYL TAPE AT THE FOLLOWING LOCATIONS: #1 - AT ANTENNA CONNECTION #2 -AT ENTRY TO EQUIPMENT CABINET 5. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK @ 12" FROM EDGE OF EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE), UP TO TOWER LEG (IF APPLICABLE), & DISTRIBUTE TO EACH ANTENNA DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND KITS PER COAXIAL CABLE ACCORDING TO ELECTRICAL DRAWINGS. VERIFY NUMBER OF ANTENNAS, CABLE & CABLE DIAMETER WITH PROJECT MANAGER. ANTENNA DETAIL 6 ANTENNA & COAX GENERAL NOTES 22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 111x17 SCALE: NTS SLOT FOR ADJUSTABLE BAND CLAMP GROUNDING CLAMP ----_ 1/4" 20 HARDWARE r PUTTY TAPE #6 GROUND LEAD / GROUNDING STRAP ASSEMBLY FIGURE 1 FIGURE 2 FIGURE 3 ELECTRICAL TAPE OVER MASTIC TAPE FIGURE 4 COAXIAL CABLE GROUNDING NTS ADJUSTABLE BAND CLAMP ~� GROUNDING CLAMP FIGURE 5 ISSUED FOR. CCONSTRUCTION REV, -DATE: —ISSUED FOR: BY: DRAWN BY:=CHK.: APV.: JRF I ORA MWO C CURRENT ISSUE DATE: 5 1lrGmc{1RF• 08-16-12 #6 GROUND LEAD TWO HOLE COMPRESSION CRIMP LUG (#6) TO GROUND BAR FIGURE 6 F<<�iI C, DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHERTHAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: RF DETAILS 'DRAWING NUMBER: RF-1 0 CEI JOB NUMBER: 12-06007 22x34 SCALE: NTS Style 1—Tower Top Mounted &Sector with 3 Quads (Sector1) OVP L/) U 2 OVP View from FRONT of Antenna Antenna 3 Antenna 2, Antenna 1. AWS LTE PCs TX/RX AWS 2100 MHz RF I... RX AWS 2100 MHz RF TX/RX PCS 1900 MHz RF W woo 41111111113111111111 RX PCS RF 1900 MHz RF DC Power (-48 V) Fiber Cable Single Mode Hybrid Cable Solution Over Voltage Protection Box AISG Cable Feeder Cable Kept for LMU QMA to DIN Jumper for LMU Dual Band TMA T • Mobile•® 19807 NORTH CREEK PKWY BOTHELI., WA 98011 OFFICE (425) 398-7600 RE�LC0M PLANS PREPARED BY: NEi-15TONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425AB7.1732 FAX:425.4871734 EMAIL: mQwmerslon ngr.mm W W W CORNERSTONE-ENGR.COM �PROJECTINFO: ISSUED FOR: CCONSTRUCTION ,,REV.-DATE:=ISSUED FOR: BY: DRAWN BY:=CHK.: APV.: JRF I DRA MWO rCURRENT ISSUE DATE: II{ 08-16-12 -PI/o 11, =DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHERTHAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. _DRAWING TITLE: RF DETAILS DRAWING NUMBER: RF-2 0 CEI JOB NUMBER: 12-06007