12-104014CITY OF
t Federal Way
October 26, 2012
Allison Zike
RealCom Associates LLC
14432 SE Eastgate Street, Suite 260
Bellevue, WA 98007
CITY HALL L',
33325 8th Avenue South
Federal Way, WA 98003-6325
(253) 835-7000
www.cityoffederalway.com
RE: File #12-104014-00-UP; PROCESS III —'PROJECT APPROVAL'
T-Mobile — SE04693 Mirror Lake, 316171" Avenue South, Federal Way
Dear Ms. Zike:
The Community and Economic Development Department has completed administrative land use review
of the proposed Personal Wireless Service Facility (PWSF) improvements located at 31517 1" Avenue
South, Federal Way. The applicant proposes to upgrade an existing Personal Wireless Service Facility
(PWSF) by replacing six (6) existing antennas and adding three (3) new antennas, for a total of nine (9)
antennas on the facility. The proposed upgrade is to prepare the site for the latest and next generation of
technology.
The Process III Master Land Use (MLU) application submitted August 29, 2012, is hereby approved
based on the enclosed findings of fact, incorporated into this decision in full, and the following
conclusions based on those facts:
l . The proposal is consistent with the comprehensive plan;
2. The proposal is consistent with all applicable provisions of Federal Way Revised Code (FWRC);
3. The proposal is consistent with the public health, safety, and welfare;
4. The streets and utilities in the area of the subject property are adequate to serve the anticipated
demand from the proposal;
5. The proposed access to the subject property is at the optimal location and configuration; and
6. Traffic safety impacts for all modes of transportation, both on and off site, are adequately
mitigated.
The remainder of this letter outlines the land use review process required for this particular site
improvement; summarizes the State Environmental Policy Act (SEPA) process; and provides other
procedural information. This land use decision does not authorize initiation of construction activities.
REVIEW PROCESSES REQUIRED
Pursuant to FWRC 19.15.030(3), improvements and/or additions to an existing developed site that are not
exempt from SEPA shall be processed under Use Process I11. The Director of Community and Economic
Development will make the initial land use decision based on written comments and information gathered
during site plan review. Any appeals of the decision will be decided by the Hearing Examiner after a
`public hearing.
Ms. Zike
October 26, 2012
Page 2
SEPA PROCESS
The City of Federal Way issued a Determination of Nonsignificance (DNS) on October 9, 2012, pursuant to
Washington Administrative Code 197-11-350. Following review of the environmental checklist, the city
determined the proposal would not have a probable significant adverse impact on the environment, and an
Environmental Impact Statement would not be required, and no SEPA based mitigation was necessary.
REQUESTS FOR CHANGE OF VALUATION
Any affected property owners may request a change in valuation for property tax purposes, not
withstanding any program of revaluation.
APPROVAL DURATION
Unless modified or appealed, the Process III decision is valid for five years from the date of issuance of
the decision. Time extensions to the decision may be requested prior to the lapse of approval following
the provisions listed in FWRC 19.15.110.
APPEALS
The effective date of issuance is three calendar days following the date of this letter, October 29, 2012.
Pursuant to FWRC 19.65.120, this land use decision may be appealed by any person who submitted
written comments or any person who has specifically requested a copy of the decision. Any appeal must
be in the form of a letter delivered to the Community and Economic Development Department with the
established fee and within 14 days after the effective date of issuance of this decision, or November 12,
2012. The appeal letter must contain a clear reference to the matter being appealed and a statement of the
factual findings and conclusion of the Director disputed by the person filing the appeal. The Federal Way
Hearing Examiner will hear any appeals of the Process III decision.
CLOSING
This land use decision does not waive compliance with future City of Federal Way codes, policies, and
standards relating to this development.
If you have any questions regarding this decision, please contact Becky Chapin, Assistant Planner, at 253-835-
2641 or rebecca.chapin@cityoffederalway.com.
Sincerely,
Isaac Conlen
Planning Manager
for Patrick Doherty, Director
enc: Exhibit `A' Statement of Findings and Conclusions
Approved Plan Set
c: Becky Chapin, Assistant Planner
12-104014 Doe. I.D. 62373
FILL
CITY OF'
Federal Way
Exhibit A
Findings for Project Approval
Federal Way Revised Code (FWRC) Chapter 19.65 `Process III Project Approval'
T-Mobile — SE04693 Mirror Lake, File 12-104014-00-UP
The Planning Division hereby presents the following analysis to the Director of Community and Economic
Development pursuant to content requirements of the Process III written decision as set forth in Federal Way
Revised Code (FWRC) 19.65.100(4).
Proposal — The applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF)
co -located on a 150-foot monopole by replacing six (6) existing antennas and adding three (3) new
antennas for a total of nine (9) antennas. The proposal also includes associated upgrades to the ground
equipment within the existing equipment shelter area.
Site Conditions — The existing PWSF is located on a 150-foot monopole on a site owned by South
King Fire & Rescue at 31617 1" Avenue South, Federal Way. The ground equipment is located within
an existing shelter; no changes are proposed to modify the equipment shelter location.
Comprehensive Plan and Zoning — The City's Comprehensive Plan designation is Single Family,
High Density and the zoning is Single Family Residential (RS 9.6). PWSFs are permitted in the RS
zone pursuant to FWRC 19.200.190.
4. Review Process — The replacement and addition of antennas to the existing PWSF is not exempt from
State Environmental Policy Act (SEPA) review and is subject to Process III `Project Approval' review.
State Environmental Policy Act (SEPA) — The proposal is not exempt from environmental review
pursuant to Washington Administrative Code 197-11-800(25)(a)(iii). The city utilized the Optional DNS
process as allowed by SEPA Rules. A combined Notice of Application and Optional Determination of
Nonsignificance was issued September 21, 2012. No comments were received during the integrated
comment period. The city's Responsible Official issued a Determination of Nonsignificance October 9,
2012. The threshold determination appeal period ended October 23, 2012, with no appeals submitted to
the Federal Way City Clerk.
6. Public Notice — Pursuant to Process III and SEPA regulations, a Notice of Land Use Application and
Optional DNS were published in the Federal Way Mirror, posted at two locations at the subject site,
and displayed on the designated city notice boards on September 21, 2012. Notices were also mailed to
property owners within 300 feet of the subject property. No comments were received on the land use
application or SEPA DNS notice.
7. Prioritized Locations — The applicant proposes to locate the PWSF on "Existing broadcast, relay and
transmission towers," which is the second priority location of the five prescribed in FWRC
19.255.010(4). Higher prioritized location, Structures located in the BPA trail, is not feasible as this
proposal is an upgrade to an existing facility. There are no alternative BPA towers in the proposed
_ vicinit~y_._Stafffind_s__the applicant has met _the -burden _to_utilize.the second: prioritized: location, The
antenna modifications should provide the full benefit of service to the area.
PWSF Development Standards — PWSFs located on existing structures shall meet development
standards prescribed in FWRC 19.255.020(1). The following are staff responses to each criterion:
a. (ii) The PWSF exceeds the minor facility thresholds for number of antennas and size, but creates
no more adverse impacts than a minor facility. Based on site photos and detailed drawings, the
proposed addition will be installed in the same manner as the previously approved antennas and
the visual impact will be unchanged.
b. The combined antennas will not exceed 15 feet above the existing rooftop facility. No height
increase is being proposed.
C. This section does not apply as the proposed PWSF is not in a right-of-way.
d. The proposed antennas will be painted to match existing conditions. The impacts to surrounding
uses will be no greater than the existing facility.
e. The proposed size and number of the antennas are necessary to meet coverage objectives as
depicted in the project narrative provided by applicant.
f. The existing ground equipment meets current regulations. Minor additional equipment is to be
added to an existing cabinet. The footprint of the facility will not be enlarged and will meet the
setback requirements.
Screening Standards — PWSFs are required to be screened using best available technology and design.
The proposed antennas will be screened and painted to match the existing antennas. These measures
appropriately mitigate visual impacts of the facility, cause no adverse cumulative effects, and meet
aesthetic standards set forth in FWRC 19.255.020(1)(d).
10. Electronics Equipment Standards — No material expansions or changes to the architectural design of
the enclosure are proposed. Therefore, these changes are exempt from PWSF standards set forth in
FWRC Chapter 19.255 and are permitted outright with no further regulatory action required pursuant to
FWRC 19.255.010(3)(g).
11. Security Screening — The PWSF includes existing structure and fencing; no new fencing or
expansion of existing fencing is proposed.
12. Cumulative Effects — The city must consider the cumulative visual effects of the PWSF mounted on
an existing structure in determining whether additional permits may be granted so as to not adversely
affect the visual character of the city. Based on the plans and photo -simulations of the proposed
modifications, the PWSF will not adversely affect the visual character of the city. The additional
antennas will be camouflaged through best available technology and design and will have less of an
impact than creating a new PWSF site.
13. Conditions of Approval — The following conditions of approval shall be a component of the
Process III land use decision:
r Prior to any site work, the applicant shall obtain an electrical permit from the city's Department
of Community and Economic Development.
14. Process III Decision Criteria — Based on the above findings, staff has determined the proposal is
consistent with applicable site plan approval criteria required for Process III `Project Approval'
pursuant to the following FWRC 19.65.100(2) items. Staff responses (italicized) follow each
criterion:
a. It is consistent with the comprehensive plan;
-The proposal is consistent with the following Federal Way Comprehensive Plan goals and
Findings for Project Approval
T-Mobile — SE04693 Mirror Lake
Page 2
File 12-104014-00-UP/Doc. I.D. 62376
PUG] — Work with private utility companies to allow them to provide full and
timely service that meets the needs of the city's residents and businesses, both
present and future.
PUG2 — Work with private utility companies to allow them to provide service in
a way that balances cost-effectiveness with environmental protection, aesthetic
impact, public safety, and public health.
PUP17 — The city should require that site specific utility facilities such as
antennas and substations be reasonably and appropriately sited and screened to
mitigate adverse aesthetic impacts.
b. It is consistent with all applicable provisions of this title;
The site plan has been reviewed under FWRC Title 19, "Zoning and Development
Code, " with specific attention to the following divisions and/or chapters: Division 1,
Administration; Chapter 19. 65, Process III Project Approval; Chapter 19.200, Single
Family Residential (RS); and Chapter 19.255, Personal Wireless Service Facilities.
c. It is consistent with the public health, safety, and welfare;
No adverse impacts are anticipated as a result of the proposal. The PWSF has received
approval from South King Fire & Rescue. The Process Ill ML U application has been
reviewed under SEPA, FWCP, and applicable provisions of the FWRC.
d. The streets and utilities in the area of the subject property are adequate to serve the
anticipated demand from the proposal;
The city's Traffic Division has determined the PWSF will not require concurrency
review and will not adversely affect the current level of service. The Lakehaven Utility
District has determined no sewer or water improvements are required for the PWSF.
e. The proposed access to the subject property is at the optimal location and configuration;
The facility is an existing site and no changes are proposed to the access points to the
facility.
f. Traffic safety impacts for all modes of transportation, both on or offsite, are adequately
.mitigated.
As the facility is unmanned, this criterion is not applicable.
These findings shall not waive compliance with future City of Federal Way codes, policies, and standards
relating to this development.
Prepared by: Becky Chapin, Assistant Planner
Findings for Project Approval
T-Mobile — SE04693 Mirror Lake
Date: October 23, 2012
Page 3
File 12-104014-00-UP/n« I.D. 62376
CITY OF
Federal Way
October 9, 2012
Allison Zike
RealCom Associates LLC
14432 SE Eastgate Way, Suite 260
Bellevue, WA 98007
CITY HALL
33325 8th Aven uth
Federal Way, WA 98003-6325
(253) 835-7000
www.cityoffederalway.com
RE: File #12-104015-00-SE; ENVIRONMENTAL THRESHOLD DETERMINATION
T-Mobile - SE04693 Mirror Lake, 3161715t Avenue South, Federal Way
Dear Ms. Zike:
The city and jurisdictional agencies have reviewed the environmental checklist submitted with the T-Mobile —
SE04693 Mirror Lake Process III Master Land Use (MLU) application. It has been determined that the
proposal will not have a probable significant adverse impact on the environment. As a result, an Environmental
Impact Statement (EIS) is not required to comply with the State Environmental Policy Act (SEPA). A copy of
the Determination of Nonsignificance (DNS) is enclosed.
The Optional DNS Process was used to review this proposal. The 14-day comment period required by SEPA
rules ran concurrently with the public comment period associated with the notice of land use application,
which began on September 21, 2012, and ended October 8, 2012. The city did not receive written comments
regarding the MLU application or environmental checklist. Pursuant to Washington Administrative Code
(WAC) 197-11-355, a second comment period is not required upon issuance of the DNS.
The enclosed DNS was issued on October 9, 2012. The city will provide a copy of the DNS to the Department
of Ecology, agencies with jurisdiction, Puyallup and Muckleshoot tribes, and anyone requesting a copy. All
final determinations may be appealed within 14 days following the issuance of the DNS. No licenses, permits,
or approvals will be issued until completion of the appeal period, which ends October 23, 2012.
The decision not to require an EIS does not grant the license, permit, or approval you are seeking from the city,
The environmental record is considered by the decision maker(s) and conditions will be imposed to reduce
identified environmental impacts, as long as the conditions are based on adopted and designated city policy.
After a final decision has been made on your proposal you may, but are not required to, publish a Notice of
Action as permitted in RCW 43.21 C.075. The Notice of Action sets forth a time period after which no legal
challenges regarding the proposal's compliance with SEPA can be made. The city is not responsible for
publishing the Notice of Action.
Questions regarding the PWSF's environmental review component should be directed to me at 253-835-2641
or rebecca.chapin@cityoffederalway.com.
Sincerely,
.�Wv�
Becky Chapin
Assistant Planner
enc: DNS
Doc, I.D. 62364
CITY 6F
Federal Way
ENVIRONMENTAL
DETERMINATION OF NONSIGNIFICANCE (DNS)
T-Mobile — SE004693 Mirror Lake
File No. 12-104015-00-SE
FILE'
Proposal: Applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) co -
located on a 150-foot monopole by replacing six (6) existing antennas and adding three
(3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment
cabinet within the fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Location: 31617 151 Avenue South, Federal Way
Lead Agency: City of Federal Way Community and Economic Development
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
The Responsible Official of the City of Federal Way hereby makes the following decision based upon
impacts identified in the environmental checklist, Federal Way Comprehensive Plan, Federal Way
Revised Code, 2009 King County Surface Water Design Manual, and other municipal policies, plans,
rules, and regulations designated as a basis for exercise of substantive authority under the State
Environmental Policy Act Rules pursuant to Revised Code of Washington (RCW) 43.31 C.060.
The lead agency for this proposal has determined that it does not have probable significant adverse impact
on the environment and an Environmental Impact Statement (EIS) is not required under RCW
43.21C.032(2)(c). This decision was made after review of a gompleted environmental checklist and other
information on file with the lead agency. This information is available to the public on request.
This DNS is issued after using the optional DNS process in WAC 197-11-355. No written comments
were received in response to the 14 day comment period that ended October 8 2012. There is no further
comment period on the DNS.
You may appeal this determination to the Federal Way City Clerk, no later than 5:00 p.m. on October 23,
2012, by a written letter stating the reason for the appeal of the determination. You should be prepared to
make specific factual objections.
Responsible Official: Isaac Conlen, Planning Manager
for Patrick Doherty, Director of Community and Economic Development
Address:
Date Issued:
33325 8`h Avenue South, Federal Way, WA 98003
Doe, LD. 62361
4k
OF
Fed40';:��
eral Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8th Avenue South
Federal Way WA 98003
253-835-7000; Fax 253-835-2609
www.citvoffederalway.com
DECLARATION OF DISTRIBUTION
I, hereby declare, under penalty of perjury of the laws of the State of
Washington, that a:
❑ Notice of Land Use Application/Action
❑ Notice of Determination of Significance
(DS) and Scoping Notice
Environmental Determination
of Nonsignificance (SEPA, DNS)
❑ Notice of Mitigated Environmental
Determination of Nonsignificance (SEPA,
MDNS)
❑ Notice of Land Use Application &
Optional DNS/MDNS
❑ FWRC Interpretation
❑ Other
❑ Land Use Decision Letter
❑ Notice of Public Hearing before the
Hearing Examiner
❑ Notice of Planning Commission Public
Hearing
❑ Notice of LUTC/CC Public Hearing
❑ Notice of Application for Shoreline
Management Permit
❑ Shoreline Management Permit
❑ Adoption of Existing Environmental
Document
was Amailed ❑ faxed Me -mailed and/or ❑ posted to or at each of the attached addresses on
_1� 2012.
� Mbt Project Name tLXA _
File Number(s)
Signature7! Date /6-9'a0/J
K:\CD Administration Files\Declaration of Distribution.doc/Last printed 1/12/2012 2:20:00 PM
CITY OF
Federal Way
ENVIRONMENTAL
DETERMINATION OF NONSIGNIFICANCE (DNS)
T-Mobile — SE004693 Mirror Lake
File No.12-104015-00-SE
Proposal: Applicant proposes to upgrade an existing Personal Wireless Service Facility (PWSF) co -
located on a 150-foot monopole by replacing six (6) existing antennas and adding three
(3) new antennas for a total of nine (9) antennas. Associated upgrades to the equipment
cabinet within the fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Location: 31617 lst Avenue South, Federal Way
Lead Agency: City of Federal Way Community and Economic Development
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
The Responsible Official of the City of Federal Way hereby makes the following decision based upon
impacts identified in the environmental checklist, Federal Way Comprehensive Plan, Federal Way
Revised Code, 2009 King County Surface Water Design Manual, and other municipal policies, plans,
rules, and regulations designated as a basis for exercise of substantive authority under the State
Environmental Policy Act Rules pursuant to Revised Code of Washington (RCW) 43.31 C.060.
The lead agency for this proposal has determined that it does not have probable significant adverse impact
on the environment and an Environmental Impact Statement (EIS) is not required under RCW
43.21C.032(2)(c). This decision was made after review of a completed environmental checklist and other
information on file with the lead agency. This information is available to the public on request.
This DNS is issued after using the optional DNS process in WAC 197-11-355. No written comments
were received in response to the 14 da comment period that ended October 8 2012. There is no further
comment period on the DNS.
You may appeal this determination to the Federal Way City Clerk, no later than 5:00 p.m. on October 23,
2012, by a written letter stating the reason for the appeal of the determination. You should be prepared to
make specific factual objections.
Responsible Official: Isaac Conlen, Planning Manager
for Patrick Doherty, Director of Community and Economic Development
Address: 33325 8tb Avenue South, Federal Way, WA 98003
Date Issued: October 9. 2012
Doc. la 62361
Tamara Fix
From: Tamara Fix
Sent: Tuesday, October 09, 2012 12:20 PM
To: 'ECY RE SEPA UNIT'
Cc: Gordon Goodsell; 'basbury@lakehaven.org'; Chris Ingham
Subject: T-Mobile Mirror Lake DNS
Attachments: Tmobile Mirror Lk DNS.pdf
Attached is the DNS for the T-Mobile Mirror Lake project in the City of Federal Way. This is being issued on October 9,
2012, and the Assistant Planner for the project is Becky Chapin, 253-835-2641, rebecca.cha in cit offederalwa .cam.
SEPA Optional DNS Notice and Checklist to the following agencies andtribes
MUCKLESHOOT INDIAN TRIBE BRANDON REYNON
ATN: ENVIRONMENTAL REVIEWER PUYALLUP TRIBE OF INDIANS
39015 172 NDAVE SE HISTORIC PRESERVATION DEPT
AUBURN WA 98092 3009 E PORTLAND AVE
TACOMA WA 98404
SOUTH KING FIRE & RESCUE
31617 1 ST AVE S
FEDERAL WAY WA 98003
DEPT OF ECOLOGY
ENVIRONMENTAL REVIEW SEC
PO BOX 47703
OLYMPIA WA 98504-7703
sepaunit@ecy.wa.gov
LAKEHAVEN UTILITY DIST
PO BOX 4249
FEDERAL WAY WA 98063
31919 is' Ave S, Suite 101 1 Federal, way, WA 98003 1253.925.5565 1 253.925.5750 (f)
Affidavit of Publication
Rudi Alcott, being first duly sworn on oath, deposes and says that he is the
Publisher of The Federal Way Mirror, a weekly newspaper. That said
newspaper is published in the English language continually as a weekly
newspaper in Federal Way, King County, Washington, and is now and
during all of said time has been printed in an office maintained by the
aforementioned place of publication of said newspaper.
That the annexed is a true copy of a legal advertisement placed by
City of Federal Way - Community Development Department
as it was published in regular issues (and not in supplemental form) of said
newspaper once each week for a period of one consecutive weeks(s),
commencing on the 21 st day of September 2012, and ending on the 21 st
day of September 2012. both dates inclusive, and that such newspaper was
regularly distributed to its readers during all of said period.
That the full amount of the fee charged for the foregoing publication is the
sum of S 144.20, which amount has been paid in full, or billed at the legal
rate according to RCW 65.16.090.
Subscribed to and sworn before me this 1 st day of October 2012.
Notary Public in and for the State of Washington,
Residing at Federal Way
NOTARY w
U, PUBLIC ; z =
r 6,; •� - ti
• -y-. •r A5.•-
rri �Or
A
Federal Way
NOTICE OF LAND 115E APPLICAriON AND
NOTICE OF OPTIONAL DETERMINATION OF
NONSIGNIFfCANCE (DNS)
Project Name; i-Mobile. - SE04693 Mirror lake
Project Description: Proposal to upgrade an exist-
ing Personal Wireless Service Facility rp4VSF) co -
located on a 150-foot mo+lopule by replacing six
(6) existing antennas and adding three ;3) new aln-
tennas for a total of nine (9) ant?ones. Associated
upgrades 10 the equipment cabinet within a fenced
equipment shelter area are also included.
Applicant: Allison like, Rea[Gorn Associates.
14432 SE Eastgate Way, Suite F60, Bellevue. WA
9R0177
Project Location; 1617 1st Avenue South. Feder
11 Warr
Hate Application Received: Auqust 29, 2012
Date Determined Complete: August 29, 2012
D a I e 0 f N o t 1 c e o f
Application: September 21, 2012
Comment Due Date: October 8, 2012
Environmental Review: Based upon review of a
::ompleted environmental checklist and oilier inf6r-
matien on fife with the City. it is fikelp that the City
of Federal Wav will determine that the project will
not have a probable significant adverse impart ❑n
the environment and expects to issue a Determina-
tion of Nohsignificanee (DNS) for this project. The
optional DNS process in WAC 197-ti-355 is betrlo
used. This may be your only opportunity to coin-
meet on the environmerilal impacts of the pro-
posed project. The proposal may include mitiga-
tion measures under applicable codes, and the re-
v{ew,process may incorporate or require mitigation
measures regardless a, 'Whether an environmental
impact statement (EIS) is prepared. A copy of the
subsequent threshold determination for the specif-
ic proposal maV be obtained upon request.
Agencies, tribes, and the public are encouraged to
review and comment on the proposed project and
its probable environmental impacts Comments
must he submitted by the date noted above,
Permits Required by This Application: Master
Land Use Process III (Fife =12-104014Lie.) and
State Environmental Policy Act Tnreshold Determi•
nation {File ifl 2- 104 01 5-S E I
Other Permits Known at this Time and Not In-
cluded in This Application: Electrical Permit
Existing Environmental Documents: None
Relevant Environmental Documents Are Avail•
able at the Address Below: Yes
Development Regalatiuns to Be Used for Project
Review Known at this Time: Federal Wav Rewser,''
Code Title 14. 'Environmentai Policy and Title 19
Zoning and Development Code.'
Public Comment & Appeals: Any person play srtb-
mit written comments on the land use application
or the environmental impacts of the proposal to
the Director of Community and Economic Devetop-
menl by 5:00 p in an October 8, 2012. Onfv per-
sons who submit .written comments Io the Ofrector
(address balotiv) or specifically request a copy of
the decision, play appeal the decision. However.
JAY Interested patty may appeal rile environmental
threshold determination. Details of appeal proce-
dt:res for the requested land use decision will be
irkciuded with the written decision
issuance o; Final Environmental Deterfnination
The final Determination of Nonsignificance may be
issued wilhoul a second comment period, unless
tilftely comments identify probable significant ad-
verse impacts that were not Considered by the No-
tice of Outioilat Determination of Nonsignificance
A copy of the Determination of Nonsigniflcance
may be obtained upon reciiest.
Availability of Fife: The official protect file Is avail-
ahle for public review al the Department of Com-
munity and Economic Development, 33325 8th Av-
enue South Federal Way. WA 98003.6325.
Staff Coutact: Becky Chapin, Assistant Plannet,
253.835 7,641
FWM1935
Date Published; September 21, 2102
O
c� N C f0 Z �Y
ca ID
dN �'i+ W
0- w
mli
° aD CO+• c6 co 4 1
O.
i F o o).C8 c a� L f _ .q U')
co a U h fu 0 �
c°`m C t 0 N N O
w ' a o O (I ; p) t) CL LL r
D n� � N C O 5 1
`�°� a -0 N
N j,, rn N
0
E �=a = L) G N LL
N N O O U
LL fA w
(6C13 N
0.2 C U C O
O N � O o
a>cm_c
�cn caQ 3
Co --- �S N
J
N
S NI GNE
—' U)
C/) M
■ �� C/)
0
U) �. f
M a, x
L
C0-
O
ui U)
CD -' \
n� � j M� S (n
W 2 � f
Cl) Z
O � N
U)MS �d -
o��
7
�1
FILE
CITY OF 40
Federal Way
NOTICE OF LAND USE APPLICATION AND
NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS)
Project Name: T-Mobile — SE04693 Mirror Lake
Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a
150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9)
antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Project Location: 31617 Is'Avenue South, Federal Way
Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012
Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012
Environmental Review: Based upon review of a completed environmental checklist and other information on file
with the City, it is likely that the City of Federal Way will determine that the project will not have a probable
significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for
this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to
comment on the environmental impacts of the proposed project. The proposal may include mitigation measures
under applicable codes, and the review process may incorporate or require mitigation measures regardless of
whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for
the specific proposal may be obtained upon request.
Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable
environmental impacts. Comments must be submitted by the date noted above.
Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State
Environmental Policy Act Threshold Determination (File # 12-104015-SE)
Other Permits Known at this Time and Not Included in This Application: Electrical Permit
Existing Environmental Documents: None
Relevant Environmental Documents Are Available at the Address Below: Yes
Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title
14, `Environmental Policy' and Title 19 `Zoning and Development Code.'
Public Comment & Appeals: Any person may submit written comments on the land use application or the
environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on
October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request
a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental
threshold determination. Details of appeal procedures for the requested land use decision will be included with the
written decision.
Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued
without a second comment period, unless timely comments identify probable significant adverse impacts that were
not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of
Nonsignificance may be obtained upon request.
Availability of File: The official gproject file is available for public review at the Department of Community and
Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325.
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
Published in the Federal Way Mirror on September 21, 2012. Doc, LD. 62208
N
U 9
N
C C f0
d N
rnu
N CJ O x 0
T
N li N
C4) C C C'u
6 3
U
y x N N
N (q (6
Ilr
j V m
d of c0 Q
C�N
Ul L
N >E'
Q N
w o
N� N w C
cClu
C L O IDIL
d
Q
wL so
C
U) cm N
N � C (D
F
. N Y
T a-o N
E
>' cc0)"
V
L ani
F
a
7 :U C -C U
(0Adh N a C
U-
.••.-O
f6
O
C N
OCL
Z N L
O (a
N C m L)
CL (n (0 Q .
\W/
i
J
L
0
L
L —C
0
CO
>
Q
0 N
♦W
VJ
A Qc)
M
0
N'l
a LLJ
� Q
r
Q
Q Ln
Q T-
T--- C)
r Q
N
LL
W
T
S N F-
N
z S NI (INZ
J F- C+1
cr):
F- _
F-
cn -N
v� r
CO
i
M z JN `
F- N
- - Cl) J f
i 04
-
'
i
l
i
i
44k
CITY
Federalo.
Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8th Avenue South
Federal Way WA 98003
253-835-7000; Fax 253-835-2609
www.cityoffederalway.com
DECLARATION OF DISTRIBUTION
I, hereby declare, under penalty of perjury of the laws of the State of
Washington, that a:
❑ Notice of Land Use Application/Action
❑ Notice of Determination of Significance
(DS) and Scoping Notice
❑ Notice of Environmental Determination
of Nonsignificance (SEPA, DNS)
❑ Notice of Mitigated Environmental
Determination of Nonsignificance (SEPA,
MDNS)
Notice of Land Use Application &
Optional DNS/MDNS
❑ FWRC Interpretation
❑ Other
❑ Land Use Decision Letter
❑ Notice of Public Hearing before the
Hearing Examiner
❑ Notice of Planning Commission Public
Hearing
❑ Notice of LUTC/CC Public Hearing
❑ Notice of Application for Shoreline
Management Permit
❑ Shoreline Management Permit
❑ Adoption of Existing Environmental
Document
was ,mailed ❑ faxed l[e-mailed and/or ❑ posted to or at each of the attached addresses on
2012.
Project Name �� d w L ► rrQ r
File Number(s) _ ]a r% 6 Yfl 15 - SF
Signature —1 Date g--'2D /c)
K:\CD Administration Res\Declaration of Distribution.doc/Last printed 1/12/2012 2:20:00 PM
CITY OF
Federal Way
NOTICE OF LAND USE APPLICATION AND
NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS)
Project Name: T-Mobile — SE04693 Mirror Lake
Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a
150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9)
antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Project Location: 31617 1 `Avenue South, Federal Way
Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012
Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012
Environmental Review: Based upon review of a completed environmental checklist and other information on file
with the City, it is likely that the City of Federal Way will determine that the project will not have a probable
significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for
this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to
comment on the environmental impacts of the proposed project. The proposal may include mitigation measures
under applicable codes, and the review process may incorporate or require mitigation measures regardless of
whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for
the specific proposal may be obtained upon request_
Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable
environmental impacts. Comments must be submitted by the date noted above.
Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State
Environmental Policy Act Threshold Determination (File # 12-104015-SE)
Other Permits Known at this Time and Not Included in This Application: Electrical Permit
Existing Environmental Documents: None
Relevant Environmental Documents Are Available at the Address Below: Yes
Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title
14, `Environmental Policy' and Title 19 `Zoning and Development Code.'
Public Comment & Appeals: Any person may submit written comments on the land use application or the
environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on
October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request
a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental
threshold determination. Details of appeal procedures for the requested land use decision will be included with the
written decision.
Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued
without a second comment period, unless timely comments identify probable significant adverse impacts that were
not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of
Nonsignificance may be obtained upon request.
Availability of File: The official project file is available for public review at the Department of Community and
Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325.
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
Published in the Federal Way Mirror on September 21, 2012. oa. Ln. 62208
m
C 75
(p
rn T
cc
-X C U
D
m LL m
U101,16
O� C C cc
N
7
U
E2 X a)N
0 c6
�U w
d C1 l9 Q N
C
U � fa Or)C-
F�r'y
N Ltf
N >.
c
Nw N
E
p
NNU
n= =
4) cm _d
N � C N
E -x
cmd_0 m N
F
a�
�
na)
7 = C 7 U
O f6 m p C
LL to w v�
y N Co (6
.M
U C U C -0
CL 0!E
N C to - U
a to ca < §
(D
cu
J
O
L
0
U)
M a,
O �
C� C:
>
� Q
O
W
U]
a) M
O
F—
a
QL]
�
ca
LL
{
CCL
G
Y
�f
W
a
O
LL
'w
D VJ
co
46
T
C)
lO
CDT
Q T
O
N O
N
T
O
O
N
U-
O
a
E ,r, S N
N
S NI ONZ �
J �
cn ,
� f
{
CO
fp'
m
U) z
_ U R
_ M Z i
A"d Z o '
N
_ N71-Cl'd
H�
�I
n ' '{v d of �
1
i
4
{
i
SEPA Optional DNS Notice and Checklist to the following agencies andtribes
MUCKLESHOOT INDIAN TRIBE BRANDON REYNON DEPT OF ECOLOGY
ATN: ENVIRONMENTAL REVIEWER PUYALLUP TRIBE OF INDIANS ENVIRONMENTAL REVIEW SEC
39015 172ND AVE SE HISTORIC PRESERVATION DEPT PO BOX 47703
AUBURN WA 98092 3009 E PORTLAND AVE OLYMPIA WA 98504-7703
TACOMA WA 98404 sepaunit@ecy.wa.gov
SOUTH KING FIRE & RESCUE
31617 1 ST AVE S
FEDERAL WAY WA 98003
LAKEHAVEN UTILITY DIST
PO BOX 4249
FEDERAL WAY WA 98063
Parcel Map and Data
G;`27 i+R9U7y
U f 27 L+f 5+2:52
i4'27 C+R92R2 y 2Np Ltd S
' S9 8T}4 ST
q df27UfuUd!^ U827049706
L4'27UR9U30 � �• �-.
_,1UR99fi
Jl271JRSl79ri
SW 31€TH ST
CV2704907f + "",`—.—
0 210 33f�39UU/U, 33ls3UU70U
Ui17U•Tu2+"ri S31frN'Pt
` Federal Way '•'`'� ._
�j ��� SSfSjUL29U
�cR � �'j 33,`S3UU2fi1
'i
,� � s3fS3CUR2J
Ufc7L+R920R q :531s:3yXjfj
= t3J53a:YJ2U 53
33fS3DUR6i+
33/;i3UURfU y
_
33f53UURRU �
65ri0fi000fU
556U6UDUSi+ SW 314T}1 Lf+t U 27UR9733
U827UR925a
�[',}fi5tiU6UC!U6�+ C,punt�U,`271R9737 Cti•ts�ti
Parcel Number 0721049210
Site Address 31617 1 STAVE S
Zip code 98003
RECEIVED
Taxpayer FIRE DISTRICT #39
The information included on this map has been compiled by King County staff from a
A U G 2 9 2012
variety of sources and is subject to change without notice. King County makes no
representations or warranties, express or implied, as to accuracy, completeness,
CITY
®F FEDERAL WAY
timeliness, or rights to the use of such Information. King County shall not be liable for any
general, special, indirect, incidental, or consequential damages including, but not limited
CDS
to, lost revenues or lost profits resulting from the use or misuse of the Information
contained on this map. Any sale of this map or information on this map is prohibited
+except�by written permission of King County."
Parcel Number
0721049017
Parcel Number 0721049014
Site Address
31627 1ST AVE S
Site Address
Zip code
98003
Zip code
LAKE HAVEN UTILITY
Taxpayer LAKEHAVEN UTILITY DISTRICT
Taxpayer
DISTRICT
Parcel Number 0721049198
Parcel Number
0721049204
Site Address
Site Address
31620 3RD PL SW
Zip code
Zip code
98023
Taxpayer JONES JAMES NORMAN+TERRI AN
Taxpayer
SHORES AT FEDERAL WAY
Parcel Number 0821049106
Parcel Number
3375300010
Site Address 31500 1 STAVE S
Site Address
102 S 317TH PL
Zip code 98003
Zip code
98003
Taxpayer GREYSTONE MEADOWS APTS
Taxpayer
COLLINS CALLEN R
Parcel Number 3375300020
Parcel Number
3375300030
Site Address 110 S 317TH PL
Site Address
31645 1ST PL S
Zip code 98003
Zip code
98003
Taxpayer GLOVER BRI,')4 I Taxpa/—) MILLIMAN PHILIP C
Parcel Number 3375300050
Parcel Number 3375300040 Site Address 31629 1ST PL S
Site Address 31637 1 ST PL S Zip code 98003
Zip code 98003 ORCHARD TERRACE
Taxpayer JURCA JIRINA Taxpayer ESTATES LLC
Parcel Number 3375300060 Parcel Number 3375300070
Site Address 31621 1ST PL S Site Address 120 S 316TH PL
Zip code 98003 Zip code 98003
Taxpayer DUNCAN RICHARD C Taxpayer PHAN TRANG PHUONG-THI
Parcel Number 3375300080 Parcel Number 3375300710
Site Address 124 S 316TH PL Site Address
Zip code 98003 Zip code
Taxpayer WALLACE-BELT EARTHA+BELT IRAN Taxpayer FEDERAL WAY CITY OF
CHARLES
King County I GIS Center I News I Services I Comments I Search
By visiting this and other King County web pages,
you expressly agree to be bound by terms and conditions of the site.
The details.
Parcel Number
'-) MetroScan /King (WA)
Owner Name
Site Address
YB Owner Phone
072104 9014
072104 9017
072104 9017
072104 9017
072104 9198
072104 9204
082104 9106
337530 0010
337530 0020
337530 0030
337530 0040
337530 0050
337530 0060
337530 0070
337530 0080
337530 0710
Lakehaven Utility District
Lake Haven Utility District
Lake Haven Utility District
Lake Haven Utility District
Jones James Norman & Terri Ann
Shores At Federal Way LLC
Greystone Meadows LLC
Collins Callen R/Sheila R
Glover Brian A
Milliman Philip C
Jurca Jirina
Canavan Daniel R/Mary L
Duncan Richard C
Phan Trang P;+
Belt Iran/Eartha
City of Federal Way
31531 1 st Ave S Federal Way 98003
31627 1 st Ave S Federal Way 98003
31627 1 st Ave S Federal Way 98003
31627 1st Ave S Federal Way 98003
*no Site Address* Federal Way
31620 3rd P1 SW Federal Way 98023
31500 1st Ave S Federal Way 98003
102 S 317th P1 Federal Way 98003
110 S 317th P1 Federal Way 98003
31645 1st P1 S Federal Way 98003
31637 1st P1 S Federal Way 98003
31629 1st P1 S Federal Way 98003
31621 1st P1 S Federal Way 98003
120 S 316th P1 Federal Way 98003
124 S 316th P1 Federal Way 98003
*no Site Address* Federal Way
1985
1977
1981
1985
1987
1989
1985
1981
1981
1981
1981
1981
1986
1986
Information compiled from various sources. CoreLogic makes no representations
or warranties as to the accuracy or completeness of information contained in this report.
*------------------- - - - - -- MetroScan / King
(WA)
`^^
Owner
:Lakehaven Utility Di: � ct
Parc
0721049014
Site
:31531 1st Ave S Federal Way 98003
Xfered
:03/16/2000
Mail
:PO Box 4249 Federal Way Wa 98063
Price
Use
:149 Rec,Parks,Zoos,Arboretum
Phone
Bedrm:
Bath: TotRm: YB:1985
Pool:
B1dgSF:2,160 Ac:4.68
*----------------------------
: MetroScan / King
(WA)
•----------------*
Owner
:Lake Haven Utility District
Parcel
:072104 9017
Site
:31627 1st Ave S Federal Way 98003
Xfered
Mail
:PO Box 4249 Federal Way Wa 98063
Price
Use
:106 Off,Office Building
Phone
Bedrm:
Bath: TotRm: YB:1977
Pool:
B1dgSF:7,440 Ac:12.03
*----------------------------
: MetroScan / King
(WA)
' •---�---------------*
Owner
:Lake Haven Utility District
Parcel
:072104 9017
Site
:31627 1st Ave S Federal Way 98003
Xfered
Mail
:PO Box 4249 Federal Way Wa 98063
Price
Use
:106 Off,Office Building
Phone
Bedrm:
Bath: TotRm: YB:1981
Pool:
B1dgSF:15,000 Ac:12.03
*----------------------------
• MetroScan / King
(WA)
•----------------*
Owner
:Lake Haven Utility District
Parcel
:072104 9017
Site
:31627 1st Ave S Federal Way 98003
Xfered
Mail
:PO Box 4249 Federal Way Wa 98063
Price
Use
:106 Off,Office Building
Phone
Bedrm:
Bath: TotRm: YB:1985
Pool:
B1dgSF:760 Ac:12.03
*----------------------------
• MetroScan / King
(WA)
•----------------*
Owner
:Jones James Norman & Terri Ann
Parcel
:072104 9198
Site
:*no Site Address* Federal Way
Xfered
:10/26/1989
Mail
:206 SW 316th St Federal Way Wa 98023
Price
:$79,503
Use
:008 Res,Mobile Home
Phone
Bedrm:
Bath: TotRm: YB:
Pool:
B1dgSF: Ac:.56
*----------------------------
: MetroScan / King
(WA)
•----------------*
Owner
:Shores At Federal Way LLC
Parcel
:072104 9204
Site
:31620 3rd Pl SW Federal Way 98023
Xfered
:06/21/2007
Mail
:9757 NE Juanita Dr #300 Kirkland Wa 98034
Price
:$19,471,500
Use
:020 Res,Condominium
Phone
Bedrm:
Bath: TotRm: YB:1987
Pool:
B1dgSF:80,850 Ac:9.49
*----------------------------
: MetroScan / King
(WA)
•----------------*
Owner
:Greystone Meadows LLC
Parcel
:082104 9106
Site
:31500 1st Ave S Federal Way 98003
Xfered
:05/17/2005
Mail
:2800 Elliott Ave #A Seattle Wa 98121
Price
Use
:011 Res,Apartment
Phone
Bedrm:
Bath: TotRm: YB:1989
Pool:
B1dgSF:317,181 Ac:18.09
*----------------------------
: MetroScan / King
(WA)
•----------------*
Owner
:Collins Callen R/Sheila R
Parcel
:337530 0010
Site
:102 S 317th P1 Federal Way 98003
Xfered
:09/14/1992
Mail
:102 S 317th Pl Federal Way Wa 98003
Price
:$134,000 Full
Use
:002 Res,Single Family Residence
Phone
Bedrm:3
Bath:2.25 TotRm: YB:1985
Pool:
B1dgSF:2,260 Ac:.26
*----------------------------
. MetroScan / King
(WA)
.-----------------*
Owner
:Glover Brian A
Parcel
:337530 0020
Site
:110 S 317th Pl Federal Way 98003
Xfered
:01/14/2008
Mail
:110 S 317th Pl Federal Way Wa 98003
Price
:$274,000
Use
:002 Res,Single Family Residence
Phone
Bedrm:3
Bath:1.75 TotRm: YB:1981
Pool:
B1dgSF:1,830 Ac:.22
*----------------------------
• MetroScan / King
(WA)
•----------------*
Owner
:Milliman Philip C
Parcel
:337530 0030
Site
:31645 1st Pl S Federal Way 98003
Xfered
:04/01/1982
Mail
:31645 1st P1 S Federal Way Wa 98003
Price
:$71,950
Use
:002 Res,Single Family Residence
Phone
Bedrm:2
Bath:1.50 TotRm: YB:1981
Pool:
B1dgSF:1,790 Ac:.20
*----------------------------
: MetroScan / King
(WA)
•----------------*
Owner
:Jurca Jirina
Parcel
:337530 0040
Site
:31637 1st P1 S Federal Way 98003
Xfered
:08/27/2004
Mail
:31637 1st P1 S Federal Way Wa 98003
Price
:$231,000
Use
:002 Res,Single Family Residence
Phone
Bedrm:3
Bath:2.50 TotRm: YB:1981
Pool:
B1dgSF:1,930 Ac:.19
Information compiled from various sources. CoreLogic makes no representations
or warranties as to the accuracy or completeness of information contained in this report.
*�----------------------------) MetroScan / King (WA)
Owner :Canavan Daniel R/Mari
Site :31629 1st P1 S Federal Way 98003
Mail :31629 1st P1 S Federal Way Wa 98003
Use :002 Res,Single Family Residence
Bedrm:3 Bath:1.75 TotRm: YB:1981 Pool:
* ---------------------------- . MetroScan / King (WA)
Owner :Duncan Richard C
Site :31621 1st P1 S Federal Way 98003
Mail :31621 1st P1 S Federal Way Wa 98003
Use :002 Res,Single Family Residence
Bedrm:3 Bath:2.50 TotRm: YB:1981 Pool:
*----------------------------: MetroScan / King (WA)
Owner :Phan Trang P;+
Site :120 S 316th P1 Federal Way 98003
Mail :120 S 316th P1 Federal Way Wa 98003
Use :002 Res,Single Family Residence
Bedrm:5 Bath:2.00 TotRm: YB:1986 Pool:
*----------------------------: MetroScan / King (WA)
Owner :Belt Iran/Eartha
Site :124 S 316th P1 Federal Way 98003
Mail :124 S 316th P1 Federal Way Wa 98003
Use :002 Res,Single Family Residence
Bedrm:3 Bath:2.50 TotRm: YB:1986 Pool:
*----------------------------: MetroScan / King (WA)
Owner :City of Federal Way
Site :*no Site Address* Federal Way
Mail :PO Box 9718 Federal Way Wa 98063
Use :300 Vacant,Residential
Bedrm: Bath: TotRm: YB: Pool:
---------- - - - - -
*
Par( _ :337530 0050
Xfered :07/19/2012
Price :$165,000
Phone
B1dgSF:1,830 Ac:.19
.----------------*
Parcel :337530 0060
Xfered :07/22/1993
Price :$119,000 Full
Phone
B1dgSF:1,980 Ac:.20
. ----------------
Parcel :337530 0070
Xfered :06/21/2002
Price :$224,500
Phone
B1dgSF:2,600 Ac:.26
.-----------------*
Parcel :337530 0080
Xfered :07/21/2003
Price :$210,000
Phone
B1dgSF:2,130 Ac:.18
•----------------*
Parcel :337530 0710
Xfered :01/05/1993
Price
Phone
B1dgSF: Ac:1.45
Information compiled from various sources. CoreLogic makes no representations
or warranties as to the accuracy or completeness of information contained in this report.
Tamara Fix
From: Tamara Fix
Sent: Thursday, September 20, 2012 8:40 AM
To: 'ECY RE SEPA UNIT'
Cc. 'basbury@lakehaven.org'; Chris Ingham; Gordon Goodsell
Subject: T-Mobile Mirror Lake NOA & Opt DNS
Attachments: Tmobile Mirror Lk NOA + Opt DNS Pkt.pdf
Attached are the NOA and Optional DNS and Annotated Environmental Checklist for the above T-Mobile project. This
NOA & Opt DNS is being issued on September 20, 2012, by the City of Federal Way. The Assistant Planner for the project
is Becky Chapin, rebecca.chapin cityofFederalway.com.
Tamara J'ix
Adi n.in .Ass t.
City cif FederaCi4-a.y
Camara. "xp atti o ederaC-wa .com
"When life gives you a hundred reasons to cry, show life that you have a thousand reasons to smile." Unknown
k
4ik
CITY OF
Federal Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8th Avenue South
Federal Way WA 98003
253-835-7000; Fax 253-835-2609
www.cityo f f e de ra Iway.co m
DECLARATION OF DISTRIBUTION
1, hereby declare, under penalty of perjury of the laws of the State of
Washington, that a:
❑ Notice of Land Use Application/Action
❑ Notice of Determination of Significance
(DS) and Scoping Notice
❑ Notice of Environmental Determination
of Nonsignificance (SEPA, DNS)
❑ Notice of Mitigated Environmental
Determination of Nonsignificance (SEPA,
MDNS)
Notice of Land Use Application &
Optional DNS/MDNS
❑ FWRC Interpretation
❑ Other
❑ Land Use Decision Letter
❑ Notice of Public Hearing before the
Hearing Examiner
❑ Notice of Planning Commission Public
Hearing
❑ Notice of LUTC/CC Public Hearing
❑ Notice of Application for Shoreline
Management Permit
❑ Shoreline Management Permit
❑ Adoption of Existing Environmental
Document
was ❑ mailed ❑ faxed M e-mailed and/or ❑ posted to or at each of the attached addresses on
2012.
Project Name �� I r 1 o b� 1� M' r a k Q
File Number(s)
Signature. Date
K:\CD Administration Res\Declaration of Distribution.doc/Last printed 1 /12/2012 2:20:00 PM
CITY OF
Federal Way
NOTICE OF LAND USE APPLICATION AND
NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS)
Project Name: T-Mobile = SE04693 Mirror Lake
Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a
150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9)
antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Project Location: 31617 1" Avenue South, Federal Way
Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012
Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012
Environmental Review: Based upon review of a completed environmental checklist and other information on file
with the City, it is likely that the City of Federal Way will determine that the project will not have a probable
significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for
this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to
comment on the environmental impacts of the proposed project. The proposal may include mitigation measures
under applicable codes, and the review process may incorporate or require mitigation measures regardless of
whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for
the specific proposal may be obtained upon request.
Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable
environmental impacts. Comments must be submitted by the date noted above.
Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State
Environmental Policy Act Threshold Determination (File # 12-104015-SE)
Other Permits Known at this Time and Not Included in This Application: Electrical Permit
Existing Environmental Documents: None
Relevant Environmental Documents Are Available at the Address Below: Yes
Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title
14, `Environmental Policy' and Title 19 `Zoning and Development Code.'
Public Comment & Appeals: Any person may submit written comments on the land use application or the
environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on
October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request
a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental
threshold determination. Details of appeal procedures for the requested land use decision will be included with the
written decision_
Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued
without a second comment period, unless timely comments identify probable significant adverse impacts that were
not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of
Nonsignificance may be obtained upon request.
Availability of File: The official pgroject file is available for public review at the Department of Community and
Economic Development, 33325 8 Avenue South, Federal Way, WA 98003-6325.
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
Published in the Federal Way Mirror on September 21, 2012. Doc. I.D. 62208
\
.o
_o
�3 k
22aam
§
E2WZEcu
a Cl)M
2 2 '
$�Kf{
`Oa°§
�@ owCL
co
@ Cc
2�MCM
2�
�C � 0
2:em!ac
LLfn 2a
� m CoCU
E 9 —0
g2ac=_
a)
�me<kSO:
a)
IVO
co
�
�
0
�
.�
75
CY)
CY)
(D
191-
C)
w
U)
I
a)
DIW
�
�
2�
§�
�
�
--
(3 T
CL
/
>
®
7."
W
CO
4 o
0
CD LO
T- o
C� C)
C�
oT---
L-
Tamara Fix
From:
Mary Lou Goss <mgoss@fedwaymirror.com>
Sent:
Wednesday, September 19, 2012 11:56 AM
To:
Tamara Fix
Subject:
T-mobile legal
Hi Tamara -
Your T-mobile legal for Friday is all taken care off...
Mary Lou
Mary Lou Goss
Federal Way Mirror
Marketing Consultant
cell - 253-229-3041
office - 253-925-5565 ext 3056
"In towns and cities where there is a strong sense of community, there is no more important institution than the
local paper." Warren Buffett
CIT
Federal Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8th Avenue South
PO Box 9718
Federal Way WA 98063-9718
253-835-7000; Fax 253-835-2609
www.cityoffederalway.com
DECLARATION OF DISTRIBUTION
1, Kennith Georae hereby declare, under penalty of perjury of the laws of the
State of Washington, that a:
❑ Notice of Land Use Application/Action
❑ Notice of Determination of Significance
(DS) and Scoping Notice
❑ Notice of Environmental Determination
of Nonsignificance (SEPA, DNS)
❑ Notice of Mitigated Environmental
Determination of Nonsignificance (SEPA,
MDNS)
Notice of Land Use Application &
Optional DNS/MDNS
❑ FWRC Interpretation
❑ Other
❑ Land Use Decision Letter
❑ Notice of Public Hearing before the
Hearing Examiner
❑ Notice of Planning Commission Public
Hearing
❑ Notice of LUTC/CC Public Hearing
❑ Notice of Application for Shoreline
Management Permit
❑ Shoreline Management Permit
❑ Adoption of Existing Environmental
Document
was ❑ mailed ❑ faxed ❑ e-mailed and/or posted to or at each of the attached addresses on
Se tember 190 2012.
Project Name T-Mobile - SE04693 Mirror Lake
File Number(s)
Signature
Date
K:\Intern\Declaration of Distribution notices\Declaration of Distribution with Posting Sites.doc
Posting Sites:
Federal Way City Hall- 33325 &h Avenue
Federal Way Regional Library- 34200 1st Way South
FedeFel Way 20h, i ,a rwy 848 Se th 2`'iwL&#e-e4 Closed for Construction
Subject Site- 31617 1st Avenue South
K:\Intern\Declaration or Distribution notices\Declaration of Distribution with Posting Sites.doc
.
CITY of
Federal Way
NOTICE OF LAND USE APPLICATION AND
NOTICE OF OPTIONAL DETERMINATION OF NONSIGNIFICANCE (DNS)
Project Name: T-Mobile — SE04693 Mirror Lake
Project Description: Proposal to upgrade an existing Personal Wireless Service Facility (PWSF) co -located on a
150-foot monopole by replacing six (6) existing antennas and adding three (3) new antennas for a total of nine (9)
antennas. Associated upgrades to the equipment cabinet within a fenced equipment shelter area are also included.
Applicant: Allison Zike, RealCom Associates, 14432 SE Eastgate Way, Suite 260, Bellevue, WA 98007
Project Location: 31617 1" Avenue South, Federal Way
Date Application Received: August 29, 2012 Date Determined Complete: August 29, 2012
Date of Notice of Application: September 21, 2012 Comment Due Date: October 8, 2012
Environmental Review: Based upon review of a completed environmental checklist and other information on file
with the City, it is likely that the City of Federal Way will determine that the project will not have a probable
significant adverse impact on the environment and expects to issue a Determination of Nonsignificance (DNS) for
this project. The optional DNS process in WAC 197-11-355 is being used. This may be your only opportunity to
comment on the environmental impacts of the proposed project. The proposal may include mitigation measures
under applicable codes, and the review process may incorporate or require mitigation measures regardless of
whether an environmental impact statement (EIS) is prepared. A copy of the subsequent threshold determination for
the specific proposal may be obtained upon request.
Agencies, tribes, and the public are encouraged to review and comment on the proposed project and its probable
environmental impacts. Comments must be submitted by the date noted above.
Permits Required by This Application: Master Land Use Process III (File #12-104014-UP) and State
Environmental Policy Act Threshold Determination (File 912-104015-SE)
Other Permits Known at this Time and Not Included in This Application: Electrical Permit
Existing Environmental Documents: None
Relevant Environmental Documents Are Available at the Address Below: Yes
Development Regulations to Be Used for Project Review Known at this Time: Federal Way Revised Code Title
14, `Environmental Policy' and Title 19 `Zoning and Development Code.'
Public Comment & Appeals: Any person may submit written comments on the land use application or the
environmental impacts of the proposal to the Director of Community and Economic Development by 5:00 p.m. on
October 8, 2012. Only persons who submit written comments to the Director (address below) or specifically request
a copy of the decision, may appeal the decision. However, any interested party may appeal the environmental
threshold determination. Details of appeal procedures for the requested land use decision will be included with the
written decision.
Issuance of Final Environmental Determination: The final Determination of Nonsignificance may be issued
without a second comment period, unless timely comments identify probable significant adverse impacts that were
not considered by the Notice of Optional Determination of Nonsignificance. A copy of the Determination of
Nonsignificance may be obtained upon request.
Availability of File: The official project file is available for public review at the Department of Community and
Economic Development, 33325 8"' Avenue South, Federal Way, WA 98003-6325.
Staff Contact: Becky Chapin, Assistant Planner, 253-835-2641
Published in the Federal Way Mirror on September 21, 2012. Doc. LD. 62208
N
L
rnf6 •X C U f6
Co LL m o U C C
NHS � ow1 aEt°
D(0 L�
mac coQ�4�
y o m "
�oT, cf�� E
L) CL N m 0 I to o.
p �? C a)M (D � 'j
v cr
aa)
~ U) Q V m
L a F• `� E 7 .0 C SL 3 U
o f0 O C
U- tow m
(6 (�
QS f6 '0
o .V C U _C a
O Z o to s
a)C CD U
dU) l6Q C
W
cu
O
L
C�
C O
CO
CO
O �
C0
,;I. Q
O
W
U ~
1 C.D
M
O
1
06
-J•�w
lLN
4 O
CD
LO
C,
r- O
m
N O
N
N �
0
c,
U-
s ... . N
S NI ONZ
o
�N
J
Cf)
Qh
_M
U)
M '
co
M
7
I
U)
i
ii-
U
!
FD
Tcf)
M
U)
5
�
Cf)
J
_
h
N
i
1
i
CITY OF
V:Zk�
Federal Way
September 20, 2012
Allison Zike
RealCom Associates LLC
14432 SE Eastgate Way, Suite 260
Bellevue, WA 98007
CITY HALL
33325 8th Avenue South
Federal Way, WA 98003-6325
(253) 835-7000
www cityoffederalway. com
RE: File #12-104014-00-UP; NOTICE OF COMPLETE APPLICATION
T-Mobile — SE04693 Mirror Lake, 31617 0 Avenue South, Federal Way
Dear Ms. Zike:
On August 29, 2012, the City of Federal Way's Department of Community and Economic Development
received your Process III Land Use application to modify the existing Personal Wireless Service Facility
(PWSF) on a 150-foot monopole, by upgrading/replacing six (6) existing antennas and adding three (3) new
antennas for a total of nine (9) antennas. The proposal also includes associated upgrades to the ground
equipment within the existing fenced -in equipment shelter area. The Comprehensive Plan designation is
Single -Family, High Density, and the zoning designation for the subject site is Single -Family Residential
(RS9.6). Pursuant to the development application submittal requirements established in Federal Way Revised
Code (FWRC) 19.65, the City has 28 days to determine whether your application is complete.
NOTICE OF COMPLETE APPLICATION
Please consider this letter as a Notice of Complete Application. Pursuant to the FWRC, the application is
deemed complete as of August 29, 2012, based on a review of your submittal relative to those requirements as
set out in the Development Requirements checklist. The submittal requirements are not intended to determine if
an application conforms to the City of Federal Way codes; they are used only to determine if all required
materials have been submitted.
Having met the submittal requirements, a Notice of Application and Optional Environmental Determination of
Nonsignificance (DNS) will be published in the Federal Way Mirror and posted at the subject property and on
the City's official notice boards within 14 days of this letter. Notification will also be mailed to persons
receiving property tax statements for property within 300 feet of the subject property.
CLOSING
A 120-day time line for reviewing the Process III application has started as of this date. The City has 120 days
from the date that an application is deemed complete to take action on the application. However, the 120-day
time line can be stopped at any time that the City requests additional information. You will be informed of the
status of the 120-day time line when you are notified in writing that additional information is needed.
If you have any questions regarding this letter or your development project, please contact me at 253-835-2641
or rebecca.chapin@cityoffederalway.com.
Sincerely,
BeckY Cha ri AAe�_—
Assistant Planner
enc: NOA/DNS
Doc. LD. 62223
CITY OF FEDERAL WAY
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL
DATE: September 4, 2012
TO: Ann Dower, Senior Engineering Plans Reviewer
Rick Perez, City Traffic Engineer
Scott Sproul, Plans Examiner
Brian Asbury, Lakehaven Utility District
Chris Ingham, South King Fire & Rescue
FROM: Becky Chapin
FOR DRC MTG. ON: Completeness Review - please email any comments.
FILE NUMBER(s): 12-104014-00-UP, 12-104015-00-SE
RELATED FILE NOS.: None
PROJECT NAME: T-MOBILE - SE04693 MIRROR LAKE
PROJECT ADDRESS:
ZONING DISTRICT:
31617 1ST AVE S
RS 9.6
PROJECT DESCRIPTION: Modify existing PWSF by upgrading/replacing six
existing antennas and adding three new antennas.
LAND USE PERMITS: Process III and SEPA
PROJECT CONTACT: Allison Zike
RealCom Associates
14432 SE Eastgate Way, Suite 260
Bellevue, WA 98007
MATERIALS SUBMITTED; Master Land Use Application
Project Description
Vicinity Map
Title Report (2)
Photo Simulations (1)
SEPA Checklist
Site Plans
27 July 2012
City of Federal Way — Planning
33325 8th Ave. South
Federal Way, WA 98003
Re: T-Mobile — SE0469A3 Mirror Lake — Proposed Modifications
To Whom It May Concern:
The intended upgrade of this cell site is required in order to prepare the site for the latest and the also the
next generation of technology. The current antenna height will remain unchanged so that the existing
coverage footprint (serving area of this site) is preserved. We do not want to adversely impact our
customers by changing the antenna height.
T-Mobile is currently modernising our Network to provide the latest technologies and enhanced voice and
data services to our customers. This upgrade is required for T-Mobile to remain competitive in the
rapidly evolving world of wireless voice and data services.
In order to be able to support the additional technologies, the site upgrade will require the addition of
three (3) antennas to the existing six (6) antennas for a total of nine (9) antennas on the site. This will
facilitate the deployment of GSM 1900, UMTS 1900 and UMTS 2100 as well as LTE.
I have attached a map showing this site and the surrounding sites in the area for your reference
I trust that this information is helpful in your review of the proposed site modification / upgrade.
Thanking you in advance.
Darryl Salk
Seattle RF Engineering, Site Deployment
-T- m -Mobile, USA
19807 North Creek Parkway N
Bothell, VVA, 98011
PNW000
DECEIVED
AUG 292012
CITY OF FEDERAL WAY
CDS
T
Area map showing T-Mobile On Air Sites
a
a
S 2 1 St
SE
SE04692H
h
SE040221 SE040361
SE04653A
SE04693A
N
SW 320th St S 320eh Sr
Q SE04014C
SE04661A
SW 336th St
� C
SE04754E
NE
SE04799A
S
E04753A
SE055814 A
y
9
z
N
z
SE04
First American Title
(WA) Commitment 1
A u . ,
First American Title Insurance Company
01
'
First American
818 Stewart St, Ste 800
Seattle, WA 98101
Phn - (206)728-0400 (800)826-7718
Fax -
King County Title Team Two
818 Stewart St, Ste. 800, Seattle, WA 98101
Fax No. (866) 561-3729
LaVonne Bowman Kelly Cornwall
Curtis Goodman
(206)336-0728 (206)336-0725
(206)615-3069
lavbowman@firstam.com kcornwall@firstam.com
cgoodman@firstam.com
Peter Child Kathy Turner
(206)336-0726 (206)336-0724
pchikl@firstam.com kturner@firstam.com
PLEASE SEND ALL RECORDING PACKAGES TO 818 STEINART ST, STE. 800, SEATTLE, WA
98101.
To: RealCom Associates
14432 SE Eastgate WAY STE 260
Bellevue, WA 98007
Attn: Sarah Telschow
File No.: 4209-1944841
Your Ref No.: T-Mobile - SE04693
Mirror Lake
Re: Property Address: 31617 1st Avenue South, Federal Way, WA 98003
COMMITMENT FOR TITLE INSURANCE
Issued by
FIRST AMERICAN TITLE INSURANCE COMPANY
Agreement to Issue Policy
We agree to issue a policy to you according to the terms of this Commitment.
When we show the policy amount and your name as the proposed insured in Schedule A, this
Commitment becomes effective as of the Commitment Date shown in Schedule A.
If the Requirements shown in this Commitment have not been met within six months after the
Commitment Date, our obligation under this Commitment will end. Also, our obligation under this
Commitment will end when the Policy is issued and then our obligation to you will be under the Policy.
Our obligation under this Commitment is limited by the following:
The Provisions in Schedule A.
The Requirements in Schedule B-I.
The General Exceptions and Exceptions in Schedule B-II.
The Conditions.
This Commitment is not valid without Schedule A and Section I and II of Schedule B.
RECEIVE®
AUG 292012
FirstAmerican Title
First American Title r.nq
First American Title
Form No. 1068-2
ALTA Plain Language Commitment
FirstAmerican rtie Insarance Company
1
A3CG�
Curtis Goodman, Title Officer
RrstAmedcan Tide
First American Title
Commitment No.: 4209-1944841
Page 2 of 10
First American Title
Form No. 1068-2 commitment No.: 4209-1944841
ALTA Plain language Commihnent Page 3 of 10
SCHEDULEA
1. Commitment Date: August 14, 2012 at 7:30 A.M.
2. Policy or Policies to be issued: AMOUNT PREMIUM TAX
General Schedule Rate
ALTA Standard Owner's Policy $ To Follow $ To Follow $ To Follow
Proposed Insured:
To Follow
Work Charge $ 450.00 $ 42.75
3. (A) The estate or interest in the land described in this Commitment is:
Fee simple as to Parcel(s) A, an easement as to Parcel(s) B.
(B) Title to said estate or interest at the date hereof is vested in:
King County Fire District No. 39
4. The land referred to in this Commitment is described as follows:
Real property in the County of -King, State of Washington, described as follows:
The land referred to in this report is described in Exhibit A attached hereto.
RmtAmerican Tithe
First American Title
First American Title
Form No. 1068-2
ALTA Plain Language Commitment
SCHEDULE B
SECTION I
REQUIREMENTS
Commitment No.: 4209-1944841
Page 4 of 10
The following requirements must be met:
(A) Pay the agreed amounts for the interest in the land and/or the mortgage to be insured.
(B) Pay us the premiums, fees and charges for the policy.
(C) Documents satisfactory to us creating the interest in the land and/or the mortgage to be insured
must be signed, delivered and recorded:
(D) You must tell us in writing the name of anyone not referred to in this Commitment who will get
an interest in the land or who will make a loan on the land. We may then make additional
requirements or exceptions.
(E) Releases(s) or Reconveyance(s) of Item(s):
(F) Other:
(G) You must give us the following information:
1. Any off record leases, surveys, etc.
2. Statement(s) of Identity, all parties.
3. Other:
SCHEDULE
SECTION II
GENERAL EXCEPTIONS
PART ONE:
A. Taxes or assessments which are not shown as existing liens by the records of any taxing
authority that levies taxes or assessments on real property or by the public records.
B. Any facts, rights, interests, or claims which are not shown by the public records but which could
be ascertained by an inspection of said land or by making inquiry of persons in possession
thereof.
C. Easements, claims of easement or encumbrances which are not shown by the public records.
D. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other facts
which a correct survey would disclose, and which are not shown by the public records.
E. (A) Unpatented mining claims; (B) Reservations or exceptions in patents or in Acts authorizing
the issuance thereof; (C) Water rights, claims or title to water; whether or not the matters
excepted under (A), (B) or (C) are shown by the public records; (D) Indian Tribal Codes or
Regulations, Indian Treaty or Aboriginal Rights, including easements or equitable servitudes.
F. Any lien, or right to a lien, for services, labor or materials or medical assistance heretofore or
hereafter furnished, imposed by law and not shown by the public records.
G. Any service, installation, connection, maintenance, construction, tap or reimbursement
charges/costs for sewer, water, garbage or electricity.
H. Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in
the public records or attaching subsequent to the effective date hereof, but prior to the date the
proposed insured acquires of record for value the escrow or interest or mortgage(s) thereon
covered by this Commitment.
FiistAmedcan Title
First American Title
First American Title
Form No. 1068-2
ALTA Plain language Commitment
SCHEDULE B
SECTION II
EXCEPTIONS
PART TWO:
Commitment No.: 4209-1944841
Page 5 of 10
Any policy we issue will have the following exceptions unless they are taken care of to our satisfaction.
The printed exceptions and exclusions from the coverage of the policy or policies are available from the
office which issued this Commitment. Copies of the policy forms should be read.
1. Lien of the Real Estate Excise Sales Tax and Surcharge upon any sale of said premises, if
unpaid. As of the date herein, the excise tax rate for the City of Federal Way is at 1.78%.
Levy/Area Code: 1205
2. The property herein described is carried on the tax rolls as exempt; however, it will become
taxable from the date of transfer to a taxable entity. Tax Account Number: 072104-9210-01
3. Lease and the terms and conditions thereof as disclosed by Memorandum of Lease.
Lessor: King County Fire District No. 39 and Lakehaven Utility District,
as Tenants in Common
Lessee: Interstate Mobilephone Company, a Washington General
Partnership, dba AT & T Wireless Services
Term: 10 years
Dated: November 27, 1995
Recorded: November 29, 1995
Recording Information: 9511291210
Said Lease, among other things, provides for an option to renew.
For a period of: 4 subsequent of optional extension terms of 5 years each
4. Lease and the terms and conditions thereof as disclosed by Memorandum of Lease.
Lessor:
King County Fire District No. 39
Lessee:
GTE Wireless of the Pacific Incorporated
Term:
5 years
Dated:
July 05, 2000
Recorded:
August 11, 2000
Recording Information:
20000811000020
Said Lease, among other things, provides for an option to renew.
For a period of: five (5) additional terms of five (5) years each
5. Unrecorded leaseholds, if any, rights of vendors and security agreement on personal property
and rights of tenants, and secured parties to remove trade fixtures at the expiration of the term.
6. Right to make necessary slopes for cuts or fills upon said premises for 1st Avenue South as
granted by deed recorded under recording no. 5331649.
FirstAmerican Title
First American Title
First American Title
Form No. 1068-2
ALTA Plain Language Commitment
Commitment No.: 4209-1944841
Page 6 of 10
7. Easement, including terms and provisions contained therein:
Recorded: July 07, 1977
Recording Information: 7707070719
In Favor Of: Puget Sound Power & Light Company, a Washington corporation
For: Electric transmission and/or distribution system
8. Easement, including terms and provisions contained therein:
Recording Information: July 19, 1978 under Recording No. 7807190971
In Favor of: Lakehaven Sewer District, a Municipal Corporation
For: Sewer mains with the necessary appurtenances
Affects: The West 10 feet of the East 92 feet of the North 275 feet of
said premises
9. Drainage Release and the terms and conditions thereof:
Between: Stanley P. Johnson and Irene R. Johnson
And: King County
Recording Information: January 20, 1983 as Recording No. 8301200660
10. Easement, including terms and provisions contained therein:
Recording Information: October 22, 1996 under Recording No. 9610221522
For: Ingress and Egress
11. Easement, including terms and provisions contained therein:
Recording Information: October 22, 1996 under Recording No. 9610221523
In Favor of: Lakehaven Utility District, a Municipal Corporation
For: Water Facilites
Affects: The Southerly portion
12. Terms, covenants, conditions and restrictions as contained in recorded Lot Line Adjustment
(Boundary Line Revisions):
Recorded: October 28, 1996
Recording Information: 9610289005
13. Covenants, conditions, restrictions and/or easements:
Recorded: November 15, 1996
Recording No.: 9611151827
14. Easement Agreement and the terms and conditions thereof:
Between: King County Fire District No. 39
And: GTE Wireless of the Pacific Incorporated, a corporation
Recording Information: August 11, 2000 as Recording No. 20000811000021
FirstAmerican Title
First American Title
First American Title
Form No. 1068-2
ALTA Plain Language Commitment
INFORMATIONAL NOTES
Commitment No.: 4209-1944841
Page 7 of 10
A. Potential charges, for the King County Sewage Treatment Capacity Charge, as authorized under
RCW 35.58 and King County Code 28.84.050. Said charges could apply for any property that
connected to the King County Sewer Service area on or after February 1, 1990. Note: Properties
located in Snohomish County may be subject to the King County Sewage Treatment Capacity
Charges.
B. Effective January 1, 1997, and pursuant to amendment of Washington State Statutes relating to
standardization of recorded documents, the following format and content requirements must be
met. Failure to comply may result in rejection of the document by the recorder.
C. Any sketch attached hereto is done so as a courtesy only and is not part of any title commitment
or policy. It is furnished solely for the purpose of assisting in locating the premises and First
American expressly disclaims any liability which may result from reliance made upon it.
D. The description can be abbreviated as suggested below if necessary to meet standardization
requirements. The full text of the description must appear in the document(s) to be insured.
LOT B, CITY OF FEDERAL WAY BLA-95-0011, REC. 9610289005, KING COUNTY
APN: 072104921001
5. Special taxes for the year 2012, which have been paid.
Tax Account No.:
072104921001
Code Area:
1205
Amount:
$ 1,922.92
Assessed Land Value:
$ 0.00
Assessed Improvement Value:
$ 0.00
F. The following deeds affecting the property herein described have been recorded within 36
months of the effective date of this commitment: NONE
G. Name and address of current taxpayer according to the King County Assessors record are:
Fire District #39
31617 1st Ave S
Federal Way, WA 98003
H. The vestee(s) herein acquired title by instrument(s) recorded under Recording
Number(s) 9611151827.
Property Address: 31617 1st Avenue South, Federal Way, WA 98003
NOTE: The forthcoming Mortgagee's Policy will be the ALTA 2006 Policy unless otherwise noted on
Schedule A herein.
NOTE: We find no judgments or Federal tax liens against the vestee herein, unless otherwise shown as a
numbered exception above.
First Ainer%Can Title
First American Title
First American Title
Form No.1068-2
ALTA Plain Language Commitment
CONDITIONS
Commitment No.: 4209-1944841
Page 8 of 10
1. DEFINITIONS
(a)"Mortgage" means mortgage, deed of trust or other security instrument.
(b)"Public Records" means title records that give constructive notice of matters affecting the title
according to the state law where the land is located.
2. LATER DEFECTS
The Exceptions in Schedule B - Section II may be amended to show any defects, liens or encumbrances
that appear for the first time in the public records or are created or attached between the Commitment
Date and the date on which all of the Requirements (a) and (c) of Schedule B - Section I are met. We
shall have no liability to you because of this amendment.
3. EXISTING DEFECTS
If any defects, liens or encumbrances existing at Commitment Date are not shown in Schedule B, we may
amend Schedule B to show them. If we do amend Schedule B to show these defects, liens or
encumbrances, we shall be liable to you according to Paragraph 4 below unless you knew of this
information and did not tell us about it in writing.
4. LIMITATION OF OUR LIABILITY
Our only obligation is to issue to you the Policy referred to in this Commitment, when you have met its
Requirements. If we have any liability to you for any loss you incur because of an error in this
Commitment, our liability will be limited to your actual loss caused by your relying on this Commitment
when you acted in good faith to:
comply with the Requirements shown in Schedule B - Section I
or
eliminate with our written consent any Exceptions shown in Schedule B - Section II.
We shall not be liable for more than the Policy Amount shown in Schedule A of this Commitment and our
liability is subject to the terms of the Policy form to be issued to you.
5. CLAIMS MUST BE BASED ON THIS COMMITMENT
Any claim, whether or not based on negligence, which you may have against us concerning the title to
the land must be based on this commitment and is subject to its terms,
cc:
cc: Lakehaven Utility
FirstAmerican Title
First American Title
First American Title
Form No. 1068-2
Commitment No.: 4209-1944841
ALTA Plain Language Commitment
Page 9 of 10
FirstAmencan Title Insurance Company
¢
First American
818 Stewart St, Ste 800
Seattle, WA 98101
Phn - (206)728-0400 (800)826-7718
Fax -
:�►► I FirstAmericen Title
prrvaq rnf.rm.tWh
We Are Commdt.d to Salegumd rig Customer Informatlan
In order to oeger serve your nerds mar and in the Nara vie may ask you to provide m with certain Information. We unde iteid that you may be caocemed abort idiot we will do with such
info-Mckin - parreu" erhy personal or h(Wdal kdmnatm. We agroe that you name a right W knoyr haw we will utilize the personal Informoum you pmvide In us. Therecre, tooef her with our
wbstdarhs we have adopW this Privacy Poky W govern the use and handing of your Pefaonal nfamaWn.
Rppilubaity
This Privxy Pally govems our use of the Information that you provide to us. It does not govem die manner In which we may use Information we bare obtained from any other source, Muth as
information ootmned from a public record or from another person or entity. First Mho ican has aho adopted broader guidelines that govem our use of persuul information regardless of its sowce.
First American calls these guidelines its Fair Information Values.
Typal of Infnrmad.n
Dep, dvig rpm which er ow Merrier you are utkmg, the types of nonpublic personal Infamhauen that we may colle-t wclude:
• Infmrnatlm receive rece tram you on appialnns, farms and in other WmrmuokNlms to us, whether In wrtrnl, In person, by telephone or any other means;
• Information about your transactions with us, our affiliated companies, or others; and
• Information we receive from a consumer reporting agency.
Use of Information
We request Information from you for our own legdk ut busncs purposes and not for the benefit of any nonafRbated parry. Therefore, snit wal not rckate ysxrr wfmmaimn to nanaffhhatmt parties
eecept: (I) as necessary for m lu p"Kilde the Nu*a a service you have nequeited arm; m (2) os permitted M law. We My, however, star such Hformat4on Yhdnnitely, tulodchg the prrioe
alter which arty customer n¢Hienrihlp has erased. Such Wommatbn may be used for airy Internal propose, suds as ghraNty [cnbd efforl1 a rrustomc arma}ysb. Svc may akn provxk all cur the type ad
nonpublic ftasmhd INamatlan Reed above to one a mom of our afniuted companies. timers NNueyd emhpanfes eM[IhAa fnarheul shyvloe prcnidas, wan as trio hrN rrers, propesry oM asuaiy
►rwrers, and IruH i[hd fnmmhrra advvsory eoaepauks, a edrrpannfes NnrWvod >n rh>as hxtak adW[es, wan ors apPrddal [ompanLa, imenx wararhty [onhpanks and ei[foMr [wnpantes. fu111KYmhae,
we may abo provide all the tfhfwmatred we muesli m desvbed abara, to vompanies fret pehfpfm maeh .ltethag services on our behalf, on balf of man alfi4ded ionVianks W to othher frham w
Institutims with whom we or our affiliated companies have joint marketing agreements.
Former Customers
Even if you are no longer our customer, our Privacy Policy will continue to apply to you.
Confidentiality and Security
We will use our best efforts to ensure that no unauthorized parties have access to any of your Information. We restrict access to nit putik pe o-A hdmoatloa about you to those individuah and
entities who need to know that information to provide products or services to you. We will use our best efforts to train and oversee our employees and agCdS to f>"ima that your Information will be
handled responsibly and in accordance with this Privacy Policy and First American's Fair Information Values. We currently maintait physkA rdectrenk, and procedural saf4ghards dial compk with
federal regulations to guard your nonpublic personal information.
Information Obtained Through Our Web Site
First American Financial Corporation is sensitive to privacy Issues on the Internet. We believe it is important you know how we treat the information about you we receive on the Internet.
In general, you can visit First American or its affiliates' Web sites on the World Wide Web without telling us who you are or revealing any Information about yourself. Our Web servers collect the
domain names, not the e-mail addresses, of visitors. This information Is aggregated to measure the number of visits, average time spent on the site, pages viewed and similar Information. First
American uses this Information to measure the use of our site and to develop Ideas to improve the content of our site.
There are times, however, when we may need Information from you, such as your name and emall address. When Information is needed, we will use our best efforts to let you know at the time of
collection how we will use the pesonal information. Usuatly, the perswhaf information we collect is used only by us to respond to your Inquiry, process an order or allow you to access specific
accountlprofile information. tryou (house to share My Personal Infomytlon wkh as, we will only use it in accordance with the policies outlined above.
Businass BalatdanaTnlps
First Amerimn Fihaadal Corporation's site and Rs afBhdreY sites may contain inks to other Web sites. While we try to link only to sites that share our high standards and respect for privacy, we are
not re4mrrs4le for the content or the privacy podicts employed by other sues.
Cookies
Some of First American's Web sites may make use of "cookie" technology to measure site activity and to customize information to your personal tastes. A cookie is an element of data that a Web site
,an send to yma bmwsa, which may then store the aotkk on your hod drive.
F Cut aldtff0 uses stored cockles. The pool of ads teAmology Is to bow serve you when visiting our she, save you time when you are here and to provide you with a more meaningful and
productive Web site experience.
Fab Information Values
Fairness We consider consumer expectations about their privacy in all our businesses. We only offer products and services that assure a favorable balance between consumer benefits and consumer
Publ a Roenrd We bearve that w ghee publk record oeates Syrlfirant value for society, eNNnbx Wnfu<hw Chace and creates ewe . vf+paturhiry We agM* Support an open Pub1k record
and dnphasae ks lmportan[e and contribution W cur a conamy.
Uses We believe we should behave vespo ul, when we use nhxrrwlton ahaut a oomumer m cur busydo . We wdl obey the ions gavem✓sB the collection. use amp deseminatan of data.
Aiculaey We wa tole rmwiatk sills W hey assure the occun icy of are data we colkcy use and disc minad. Where pmsnle, we will take reasonable ceps to correct inaccurate information.
When. m with the pubs record, we Cannot correct lnacm,,Mt infmnatka, we will take all mmonabk Sups W assht mrounim in Ideril"j; rime soiree or the erroneous data se that vie cwamox
run secure the required corrections.
educwdoh We endeahmr to educate the user of our pradult, and serOm, au emplpyeef area ntkss A cur kAntry. abaft the Import" of canwnw prvacy. We Will Instruct our emmptoyecr on
dtm fall Information values and on the respons4hk [oienim and use of dahl. We call bm[uuiyb OS}Ipf lA err tmdl4aY W Chian add use nformaw n a rnpomble manner.
Security We wor maintain apprcryWte fad6tks cord systfms W protect against IumaathRiTld aPc�a w.attd Witt Uyatf the dam we miauiaam.
Form 50-PRIVACY (8/1/09) Page 1 of 1 Privacy Information (2001-2010 First American Financial Corporation)
FirstAmerican Title
First American Title
First American Title
Form No. 1068-2 Commitment No.: 4209-1944841
ALTA Plain Language Commitment Page 10 of 10
FIRSTAMERICAN TITLEINSURANCE COMPANY
Exhibit "A"
Vested Owner: King County Fire District No. 39
Real property in the County of King, State of Washington, described as follows:
PARCEL A:
LOT B OF CITY OF FEDERAL WAY BOUNDARY LINE ADJUSTMENT NO. BLA-95-0011 RECORDED
OCTOBER 28, 1996 UNDER RECORDING NO. 9610289005 IN KING COUNTY, WASHINGTON.
PARCEL B:
A NON-EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS AS ESTABLISHED IN RECORDED OCTOBER
22, 1996 UNDER RECORDING NO. 9610221522, IN KING COUNTY, WASHINGTON.
EXCEPT ANY PORTION WITHIN PARCEL A ABOVE.
Tax Parcel Number: 072104921001
Situs Address: 31617 1st Avenue South, Federal Way, WA 98003
FirstAmerlcan Title
First American Title
First American Title
2. Map -Customer
Dot .0 V6 'I s.Lb4 "a i;row nnno 2A .UWIQ ON n�
's �7•Rl[I 75: 9C-f0-1 R psi
� 9F-rA-Ip H - - •• _
First American Title
RECEIVE
SE04693A MIRROR LAKE- „
=a NRSIMNE CINGULAR- KC FIRE p,Uri
4E0 �2011 Get
EXISTING SOUTH ELEVATION
• Mobile -
more from life
CITY OF F1gD� ERAL WAY
CDJ
'r4; -
CL
.. +r ---+ i-�-i
SE04693A MIRROR LAKE- T R .Mobile ■-
m FgFINERSlro9VE CINGULAR- KC FIRE
EXISTING EAST ELEVATION Get more from life
SE04693A MIRROR LAKE-
�_ o �o�r�e�s�rorve CINGULAR- KC FIRE
PROPOSED EAST ELEVATION
:dry -Mobile-
Get more from iife
PROJECT DESCRIPTION
INTRODUCTION
T-Mobile is a wireless telephone company operating throughout the United States of America. T-
Mobile is licensed to operate in the United States by the Federal Communications Commission
(FCC). T-Mobile is currently expanding its network in the King County area to make available
improved telephone service and provide wireless capacity to its subscribers.
This proposal describes the scope of the proposed project by providing specific information
regarding the project location, zoning, specifications, and required services.
It is T-Mobile's desire to work with the City of Federal Way to ensure that this project is consistent
with local ordinances and zoning regulations while providing wireless coverage to T-Mobile's
customers and provide critical communication services for emergency, business, and personal use.
Project Goals
The goal of the T-Mobile SE04693 Mirror Lake Site is to upgrade T-Mobile's existing network to
provide better telephone service. T-Mobile intends to achieve these network goals consistent with
all policies and ordinances of the City of Federal Way.
Application Request Plan
The applicant is requesting the following:
■ Process III Land -Use Review
* SEPA Review
IN Commercial Building Permit
T-Mobile
SL0,1693 Mug or Like
Page t
RECEIVED
AUG 292012
CITY OF FEDERAL WAY
CDS
GENERAL PROJECT DESCRIPTION
Project Overview
The applicant, T-Mobile, proposes to modify an existing telecommunication facility located at
31617 1st Ave South (Parcel No. 0721049210) to provide expanded services.
The proposed modification consists of the following: Upgrade/replace six (6) existing antennas
and add three (3) new antennas. Please see Sheet. A-1.2 and A-2 for additional information.
Facility Specifications
■ Antennas - T-Mobile is proposing to upgrade/replace six (6) existing antennas and add
three (3) new antennas. Please see Sheet A-1.2 and A-2 for additional information.
■ Color - The antennas and associated mounting hardware will be painted to match the
existing site conditions.
■ Facility Maintenance - The facility is generally serviced once a month. One (1) to two (2)
employees are on site for an average of four (4) hours of maintenance checks. This check
is typically for preventive maintenance purposes. In the event of a problem, a crew is
dispatched to the site immediately.
■ I. uidsca )in r Scrceiiin - No changes are proposed to the existing on -site screening.
GENERAL SITE ANALYSIS
Zoning General Plan Designation
The property is zoned RS-9.6. According to the Federal Way Revised Code (FWRC) 19.200.190
the proposed modification would require the review and approval of a Process III Land Use
Review, SEPA Review, and Commercial Building Permit:
The follwAring uses shall be permitted in the single-fiunily residential (RS) zone
subject to the regulations and notes set forth in this section:
T-Mobile
SAVAiMlY Miii or Lake
Page 2
USE ZONE CHART
DIR EC TIONS: FIR ST, read doifmto find u:se . . TH EN, across for R EGULATIONS
Nini mu ms
70-,F.
`lards
Required
Required
q
Maxi n-ru rn
Required
Us �
{
USE REGULATIONSSide
Review
Lot
Height
Lands_ape
Signs
Parking
Process
Size
IFrcnt
Spaces
�e -
SPECIAL
. .Rear
led h.
REGU LAT IONS
d
AND NOTES
PersonaImire less
Process
See
See
See
See
Refer to
Seenote 2
Not
NIA
1.Not
:service faeilibj
II
note
note
note 1
note
FUURC
allokned
applicable.
(PUUSF)
1
1
1
19.255,020
on a
Puri S'Fs allovtled
See note 3 for
for
IPUUSF
on existing
allowed bjpes of
maximum
structures only.
PUUS Fs
heights for
2. All PUU S Fs
allowed
shall be
types of
landscaped and
P'uUSFs
sore ened in
accordance with
Chapter 19.125
FUURC and the
p rovis in ns of
the Puri SF
development
regulations. At a
minimum, a five
ft. type III
landscaping
area shall be
required around
the fa cility,
unless the
community
development
services
director
determines that
the facility is
adequately
screened
3. N ew
freestanding
PUUSFs are not
allowed.
P'uUSFsshall be
a lowed only on
existing towers,
'on publicly used
structure= not
located in public
on
structures
1�} ca W_ d in the
T-Mobile
SE0,16,93 Minor Lake
Page 3
BPAtrail, an, or
exis ti ng
structures in
appropriate
public rights -
of -way. Refe to
FWRC
19.255.02D 1
development
standards
applicable to
alowedtype of
PtiAlSFs.
For other
information
about parkin
and parking
Process I, II, III and fV are described in
dfeaS,s ee
Chapter 1955 FWRC, Chapter 19-1 LQ
Chapter 19.BO F'OVRC, FWRC
Chapter 19.B5 FVYRC, For details o
Chapter 19.70 FWRC respectivety. what may
exceed this
height limit,s ae
FWRC
19.1101D50
seq.
For details
regarding
required yar
see FWRC
19.125.160
seq.
(Ord. No.09.6v3. § 12. 11-17-09: Ord- No.00-3363,§ 4. 1-400; Ord No. 97.300,§ 3, 9.16.97. Code2001
§ 22-649.)
'Cross rderences: Parking commercial vehicles in R S districts, FUURC S50.020; legislative rezoning
procedure applicable to this district, FWRC 19.35.040; supplementary district regulations, FWRC Title 19,
DivisionViI.
Accordingly, T-Mobile is requesting the review and approval of a Process III Land Use Review,
SEPA Review, and Commercial Building Permit.
Development Standards
According to the FWRC 19.255.020:
The follorrirrg development stuAuds shall he follm ed in the design, siting; uld
comouctioli ofz personal rflir-eless sei-race facility.•
(1) Building- or so-uctur-e-rlloullted PWSFs orl el7strng hurldrngs or- souctui-es in
or- out of the public right-of-vrwy. PWSFs mounted on evstilig huildiigs vnd
structures shall conform to the follorringdeveloprniaw stvldards:
(q) The PWSFsljdl consist wily o1-tlle follorTirng types off7cdities:
(i) A rllrcl-ocell or -a mjrior Acrllty7 or
(rr) A PWSF that exceeds the minor facility thresholds for- mmnbel- of
aliterilias, dimernsrorls, xidlor- area, but creates rlo mole adverse
impacts drvi a minor facility; as deteiuriried by the director of-
conlmunity development sei-races, suhicct to meeting- all of- the
10116 rririg st vid u ds:
(A) The facility shill not cl-ezte suhstmli dly more adivisc raswd
impact thin z lilrrlol-ficrlrty; vnd
T-Mobile
SE04693 Mirror- I Ike
Page 4
(B) The equipment cabinet for the PWSF shall meet all
regeurcineuts of subsection (f) of this section; vid
(C) The inaxiinmn size of the PWSF pviels vid number of•
viteiitias sh d] be determined by the diiector of conunuinty
development services, based on the specific project location,
sm7oundmgemironnient, audpolenfid vosualimpacts; vid
(D) The PWSF shall comply with dll other applicable stimdai ds of
the Federal Wty, Re rased Code.
(b) The combined uiterinas grid supporti ig-structure may erlend up to, but
not erceed, 15 feet above the existing or proposed roof or other
structure regardless of whether the existing stiuclure is in confoiirivicc
u th the existing in2rrmurn height of the underlying zone as outlined iri
the use zone chits, FWRC Tide 19, Division W,, Zoning Regulations.
Auterinas may be mounted to rooFop appuitenvices, as identified in
FWRC 1.9.110.070, provaded they do not extend beyond 15feet above
the maximum height of the structure as defined per FWRC 1-9.OS. 080,
H definitions...
T-Mobile's proposed modifications will not create additional adverse impacts.
Screening Standards
According to the FWRC 19.255.020(3):
Screening standards for all PWSF.". PWSFs shall be screened or (mloull:�,ml
through employing (lie best available technolov acid desibm, as ddertnined by the
city. `!'Iris may be accomplished by use of' compatible materials, location,
landscaping, color, stealth techniques such as, but not limited to, artificial tines
and hollow flag poles, and/or other methods or techniques to achieve minimum
visibility of the facility as viewed from public streets or residential properties. In
addition, the provisions for landscaping as outlined in the use zone charts, FWRC
Title 19, Division VI, Zoning Regulations, shall apply.
The new antennas will be painted to match the existing tower.
Standards for Flectronic Cabinets
According to the FWRC 19.255.020(4):
Standards for electronic cabinets.
(a) Electronic cabinets shall either:
(i) Be placed in a new or existing completely enclosed building. It is the
applicant's responsibility to prove that the maximum size of tine
building is the minimum size necessary to house the equipment; or
(ii) Be placed above ground in a new or existing equipment enclosure.
It is the applicant's responsibility to prove that the maximum size of
the building is tine minimum size necessary to house tine equipment.
(b) Equipment enclosures shall be screened With one or a combination of
the following methods, which shall be acceptable to the city: fencing,
walls, landscaping, structures, buildings or topography which will block
the view of the equipment enclosure to the greatest extent possible from
any street and/or adjacent properties, as determined by the director of
community development services. Screening may be located anywhere
between the enclosure and tine above -mentioned viewpoints.
T-Mobile
SE046.93 Mirror L7A-c
Page 5
I andscaping for the purposes of screening sliall be m<unt<uned in a
healthy condition, pursuant to F\VRC 19.125.090(2). -
(c) If the equipment cabinet is located iaithin a new enclosed building, the
building shall conform to all applicable development standards mid
design guidelines for the underlying zone. The enclosed building shall be
achitecturally designed mid sli<all be compatible Nvith existing buildings
on the site. The enclosed buildnig sliall be screened to the greatest extent
possible from any street mid/or adjacent properties by landscaping
and/or topography.
T-Mobile is not proposing any changes to the equipment cabinets and/or the enclosure.
Standards for Equipment Enclosures
According to the PWRC 19.255.020(5):
Standards for equipment enclosures.
(a) Electronic equipment enclosures sliall not be allowed within the night-of-
Avay.
(b) In residential zones, equipment enclosures located above ground on
properties adjacent to the public right-of-way shall meet all applicable
setback requirements for residential development of the Underlying
zone. For developed sites in nonresidential zones, the setback
requirements for the equipment enclosure shall be those of the principal
use of the subject property. For undeveloped sites in nonresidential
zones, the setback requirements for the equipment enclosure shall be 20
feet for front, side, and rear yards. However, for undeveloped sites in
nonresidential zones, if the applicant can demonstrate that the
equipment enclosure car blend in harmoniously with the existing site
and complement the landscape buffer requirements of the underlying
zone, as determined appropriate by the director of community
development services, the equipment enclosure can be located inside of
the 20-fool setback but outside of the required landscaping buffer of the
underlying zone.
(c) Equipment enclosures shall be designed, located, and screened to
minimize adverse visual impacts from the public right-of-way and
adjacent properties.
(d) Equipment enclosures shall be designed, located, and screened to
minimize adverse visual and functional impacts on the pedestrian
environment.
(e) Equipment enclosures and screening shall not adversely impact vehicular
sight distance.
T-Mobile is not proposing any changes to the equipment cabinets and/or the enclosure.
T-Mobile
SIs01693Mj�iorL ke
Page 6
Security Fencing
According to the FWRC 19.255.020(6):
Security fencing.
(a) No fence sliall exceed six feet in height as stipulated in FWRC
19.12.5.160(5).
(b) Security fencing sliall be effectively screened from view through the use
of appropriate landscapuig materials.
(c) Chain -link fences shall be painted or coated with a nonreflective color.
T-Mobile is not proposing any changes to the equipment cabinets, the enclosure, and/or the
fencing.
Existing Use
The subject area accommodates existing telecommunication facilities.
Access/Circulation
The site will be accessed by the existing right of entry. There are no traffic impacts associated with
these types of facilities as they are unmanned and require infrequent maintenance.
FCC Time Period Guidelines
On November 18, 2009, the FCC issued a Declaratory Ruling (FCC-09-99A1) that created periods
of time under the Telecommunications Act (TCA) in which zoning authorities must act upon siting
applications filed by wireless carriers or be in violation of the TCA. Specifically, the timelines are
as follows: ninety (90) days for co -locations and one hundred fifty (150) days for all other sites
including new towers. Please see the FCC Declaratory Ruling 09-99A1 for more detailed
information.
Federal Requirements
T-Mobile's telecommunication facility will meet or exceed current standards and regulations of the
FAA, the FCC, and any other agency of the Federal government with the authority to regulate
towers and antennas.
T-Mobile's site will conform to all FAA/FCC regulations, and because the maximum ERP is less
than two thousand (2,000) watts and/or the height of the facility is greater than ten meters (10m),
an environmental evaluation of radio frequency emissions is exempted per CFR Title 47 Part 24,
Subpart E.
T-Mobile has a license from the FCC to provide wireless telecommunication services throughout
Washington State.
T-Mobilc
SE04693 Mirror Lake
Page 7
41k
CITY OF 40'::tt�:P
Federal Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8`h Avenue South
Federal Way, WA 98003-6325
253-835-2607;Fax 253-835-2609
w w w. e i t yo f federal way. cow
ENVIRONMENTAL
a�� C�ir1
j NAY
CHECKLIST
PURPOSE OF CHECKLIST
The State Environmental Policy Act (SEPA), Revised Code of Washington (RCW) Chapter 43.21C,
requires all governmental agencies to consider the environmental impacts of a proposal before making
decisions. An environmental impact statement (EIS) must be prepared for all proposals with probable
significant adverse impacts on the quality of the environment. The purpose of this checklist is to provide
information to help you and the agency identify impacts from your proposal (and to reduce or avoid
impacts from the proposal, if it can be done) and to help the agency decide whether an EIS is required.
INSTRUCTIONS FOR APPLICANTS
This environmental checklist asks you to describe some basic information about our proposal.
Governmental agencies use this checklist to determine whether the environmental impacts of your proposal
are significant, requiring preparation of an EIS. Answer the questions briefly, with the most precise
information known, or give the best description you can.
You must answer each question accurately and carefully, to the best of your knowledge. In most cases, you
should be able to answer the questions from your own observations or project plans without the need to
hire experts. If you do not know the answer, or if a question does not apply to your proposal, write "do not
know" or "does not apply." Complete answers to questions now may avoid unnecessary delays later.
Some questions ask about governmental regulations, such as zoning, shoreline, and landmark designations.
Answer these questions if you can. If you have problems, the governmental agencies can assist you.
The checklist questions apply to all parts of your proposal, even if you plan to do them over a period of
time or on different parcels of land. Attach any additional information that will help describe your proposal
or its environmental effects. The agency to which you submit this checklist may ask you to explain your
answers or provide additional information reasonably related to determining if there may be significant
adverse impact.
USE OF CHECKLIST FOR NON -PROJECT PROPOSALS
Complete this checklist for non -project proposals, even though questions may be answered "does not
apply." In addition, complete the Supplemental Sheet for Non -Project Actions.
For non -project actions, the references in the checklist to the words "project," "applicant," and "property
or site" should be read as "proposal," "proposer," and "affected geographic area," respectively.
RECEIVED
AUG 29 2012
Bulletin #050 — January 1, 2011 Page 1 of 18 k: t fli IAktist
Cps
BACKGROUND INFORMATION
Property Owner: South King County Fire & Rescue
Address: 31617 1st Avenue South
City/State/Zip: Federal Way, WA Phone:
Applicant: T-Mobile
Address: 19807 North Creek Parkway
City/State/Zip: Bothell, WA 98011 Phone: (425) 398-7600
Agent: RealCom Associates - Allison Zike
Address: 14432 SE Eastgate Way, Suite 260
City/State/Zip: Bellevue, WA 98007 Phone: (425) 274-4444 ext. 112
Name of Proposed Project: "1:-Mobile SE04693 Mirror Lake
Location of Project:
Address:
Quarter:
Tax Parcel Number(s):
Federal Way, Washington
33616 21 st Avenue SW
Section: 7 Township: 21 Range: 4
0721049210
4. Date checklist prepared:
August 21, 2012
5. Agency requesting checklist:
City ol'Tederal TAT'ay
6. Proposed timing or schedule (including phasing, if applicable):
The construction xill commence as soon as all applicable pehniils are obtained.
2. Do you have any plans for future additions, expansion, or further activity related to or
connected with this proposal? If yes, explain.
At this 011ie, T 11oblle does not hai e pbuis for 1Ulum additions, mpansious, or luoure activity comlected rrilh
this project. However in the future, mal*cl cone lions could necessitate the ]feed 101' a(khOUllal alhlClll]aS at
this location.
8. List. any environmental information you know about that has been prepared, or i ' be
prepared, directly related to this proposal.
T-Mobile and its agents ale not ar-flare ofally precious enTironmental infoiniation that has been prepared on
tie project site that would adecl this proposal other dhalh previous SEPA Checklists subnlitled to tie City of
Federal Way for the ex7sling telecommuliicatiou la fides.
T-Mobile
SE04693 Mirror Lake
SEPA Checklist - Page 2
9. Do you know whether applications are pending for governmental approvals of other
proposals directly affecting the properly covered by your proposal? If yes, explain.
T-Mobile and its agents are not ar-we ol'vey applications) pendmggovenrmental approvals) that would
directly allect the property covered by this project.
10. List any government approvals or pen -nits that will be needed for your proposal, if known.
The T-Mobile SE04693 Mirror Lie project requires the follornrrg approvals:
■ Process III Land -Use Review
• State Enraronmeutal Policy Act (SEPA) Review
■ Commercial Building Permit
11. Give brief, complete description of your proposal, including the proposed uses and the size
of the project. There are several questions later ui this checklist that ask you to describe
certain aspects of your proposal. You do not need to repeat those answers on this page.
(Lead agencies may modify this form to include additional specific information on project
description.)
The applicant, T-Mobile, proposes to modify au existurg telecommunication facility located at 31617 F Ave
South (Parcel No. 0721049210) to pror4de expanded serraces.
The proposed modification consists oftlie follou ng.• Replace/upgfade six (6) existing antennas; add three (3)
nera vrtemras fora total ol'irine (9). Please see Sheet A-1.2 and A-2 for additional information.
12. Location of the proposal. Give sufficient information for a person to understand the
precise location of your proposed project, including a street address, if any, and section,
township, and range, if known. If a proposal would occur over a range of area, provide the
range or boundaries of the site(s). Provide a legal description, site plan, vicinity map, and
topographic map, if reasonably available. While you should submit any plans required by
the agency, you are not required to duplicate maps or detailed plans submitted with any
permit applications related to this checklist.
77re project is located at 316171" Ave Soulh, Federal 147aj; N,askiigion rridlin King Counly. Please see the
Aerial-Vicinili, Map in the SE PA E hihils for more detailed infornalion.
B. ENVIRONMENTAL ELEMENTS l
1. Earth conaKir W G%C ��►6� �q I
a. General description of the site (underline one):
flat, rolling, hilly, steep slopes, mountainous,
outer:
b. What is the steepest slope on the site (approximate percent slope)?
In the area dial the teleconnnunicatioir facility is proposed, the steepest slope is approximated at less
than percent (50).
T-Mobile
SE,04693 Minor LAe
SEPA Checklist - Page 3
c. What general types of soils are found on the site (for example, clay, sand, gravel,
peat, muck)? If you know the classification of agricultural soils, specify them and
note any prune farmland.
The general types of-soillound on the site are not knomi.
d. Are there surface indications or history of unstable soils in the immediate vicinity?
If so, describe.
There are no surface indications and/or history of unstable soils in die immediate rocmity of the
project.
e. Describe the purpose, type, and approximate quantities of any filling or grading
proposed. Indicate source of fill.
There is no proposed grading associated with this project.
f. Could erosion occur as a result of clearing, construction, or use? If so, generally
describe.
Erosion is very unlikely. Homever, Best Management PM, Ctices OMP's) for erosion control will be
implemented duringconstuction.
g. About what percent of the site will be covered with impervious surfaces after project
construction (for example, asphalt or buildings)?
T-Mobile is not proposing vhy newimpenaous surlaces.
h. Proposed measures to reduce or control erosion, or other impacts to die earth, if
any:
3. Air
All standard erosion conti-ol methods will be utilized to reduce or control erosion, or otherinhpacts
to the earth.
Cc711Clnr W CIIS l —C)
a. What type of emissions to the air would result from the proposal (i.e., dust,
automobile, odors, industrial wood smoke) during construction and when the
project is completed? If any, generally describe and give approximate quantities if
known.
During- construction, there Will be very minor dust and emissions associated a d1 construction
madlinei7/r elhicles. There are no signrlicant emissions associated u411i project operation.
b. Are there any off -site sources of emissions or odor that may affect your proposal?
If so, generally describe.
T-Mobile and its agents are not arrwe of any ofTsite sources ofemissions or odor that mould affect
this proposal.
T-Mobile
SE04693 Mimi- Lake
SEPA Checklist - Page 4
c. Proposed measures to reduce or control emissions or other impacts to air, if any:
All standard measures to reduce and/or control emissions during construction uiU be utilized.
These measures inay include the regular use of'watering vehicles to attenuate dust pavticles on -site
and proper rnainten lice ofall vehicles to limit emissions.
4. Water
a. Surface:
C'ahCO( lr C��rl�lt�l' C�►-d)
(1) Is there any surface water body on or in the immediate vicinity of die site
(including year-round and seasonal streams, saltwater, lakes, ponds, wetlands)?
If yes, describe type and provide naives. If appropriate, state what stream or
river it flows into.
Mirror Lake is approximately 950 Ieet away fi-om the existing toner. It is unl nouw what
steams or fivers Mirror Lake flows into. No Ke-
(2) Will the project require any work over, in, or adjacent to (within 200 feet) the
described waters? If yes, please describe and attach available plans.
This project gill not require any w otA over, m, or adjacent to (within 2001eet) ofaily waters.
(3) Estimate the amount of fill and dredge material that would be placed in or
removed from surface water or wetlands and indicate the area of die site that
would be affected. Indicate the source of fill material.
This project will not fill and/or dredge material lrom sullace watei/wetlands.
(4) Will die proposal require surface water wididrawals or diversions? Give
general description, purpose, and approximate quantities if known.
This project mill not iequire suilice water rritlidlarrals or diversions.
(5) Does the proposal lie within a 100-year floodplain? If so, note location on the
site plan.
This project does not lie within a 100Deal-floodplain. Please see [he EEMA Map in the SE, PA
Exhibits Ior more detailed uilonnation.
(6) Does die proposal involve any discharges of waste materials to surface waters?
If so, describe the type of waste and anticipated volume of discharge.
This proposal does not invoke ally dischvges of waste materials to suilace waters.
b. Ground:
(1) Will ground water be withdrawn, or will water be discharged to ground
water? Give general description, purpose, and approximate quantities if
known.
T-Mobile
SE04693 Mirror Lake
SEPA Checklist - Page 5
No g-oundraaler Ta711 be Taathdrarvrh md/or Taater disclharged to tie g-oundraater:
(2) Describe waste material that will be discharged into the ground from septic
tanks or other sources, if any (for example: domestic sewage; industrial,
containing the following chemicals ...; agricultural; etc.). Describe the
general size of die system, the number of such systems, d-ie number of
houses to be served (if applicable), or the number of animals or humans the
system(s) are expected to serve.
No raasle mateiiVs mall be discharged into the p-ound from septic tanks or other sources.
C. Water Runoff (including storm water):
(1) Describe the source of runoff (including storm water) and method of
collection and disposal, if any (include quantities, if known). Where will
this water flow? Will this water flow into other waters? If so, describe.
The project rail] not alter or rmpacl the existing storm drainage system.
(2) Could waste materials enter ground or surface waters? If so, generally
describe.
This tJpc project does not generate raaste materials. Therelore, it is Tejy unlikely that
raasle matehials would enter the ground or suilace waters, however all preventive measures
mall be taken.
d. Proposed measures to reduce or control surface, ground, and runoff water
impacts, if any:
4. Plants
At this time, there are no proposed measures to reduce or control surface Taater g-oundrTaler,
and runofl:
COT" V;A C ts� �a_ d)
�
a. Check or circle types of vegetation found on the site:
X deciduous tree: alder maple, aspen, other
X eierg7cen tree: fn-, cedar, pine, other
_X shrubs
X '-2-ass
-- pasture
-- crop org-vn
wet soil plants: catlad, buttercup, bullmsh, skunk cabbage, other
walerplants: Tvaterlilj; eelgass, milfoil, other
other tjpes of vegetation
b. What kind and amount of vegetation will be removed or altered?
No vegelatiou Taal] be removed
c. List threatened or endangered species known to be on or near the site.
No threatened vhd/or endvigered plant species are knoram to be on or near tie site.
T-Mobile
SE04693 Mirror Lake
SE PA Checklist - Page 6
d. Proposed landscaping, use of native plants, or other measures to preserve or
enhance vegetation on the site, if any:
At this time, rro Ivrdscapinghas been proposed.
5. Animals
Co w v r-4 C taW sF (")
a. Underline any birds and animals that have been observed on or near the site or are
known to be on or near the site:
birds: bar4Z, heron, eagle, songbirds, other:
mammals: deer, bear, elk, bearer, ulBcrr
fish: bass, salmon, trout, Bening, shellfish, other:
b. List any threatened or endangered species known to be on or near the site.
No threatened vid/or endangered ,vernal species are knorui to be on ornear die site.
c. Is the site part of a migration route? If so, explain.
T-Mobile and its agents are not amwe of i migration route near the site.
d. Proposed measures to preserve or enhance wildlife, if any:
AI this lime, lhcrt at a no plvposed measures to preserve or enh.urcr I tif,111 c. 1\
6. Energy and Natural Resources or�Nr TA INC;kltS�
C
a. What kinds of energy (electric, natural gas, oil, wood stove, solar) will be used to
meet the completed project's energy needs? Describe whether it will be used for
heating, manufacturing, etc.
Electric porr•er rrill be utilized to operate the anteimas and associated electiical equipment.
b. Would your project affect the potential use of solar energy by adjacent properties?
If so, generally describe.
The subject proposal Trill not a1kct Me potential use of'solar energy by adjacent properties.
c. What kinds of energy conservation features are included in the plans of this
proposal? List other proposed measures to reduce or control energy impacts, if
any:
At this time, there are no energy consen atron features included in the plans of tlrrs proposal.
T-Mobile
SE04693 Mirror Lake
SEPA Checklist - Page 7
7. Environmental Health
C'01\MY V;6 C4vc�C,,A. Ca—bi
a. Are there any environmental health hazards, including exposure to toxic chemicals,
risk of fire and explosion, spill, or hazardous waste, that could occur as a result of
this proposal? If so, describe.
No sucli Hazards have been identified raids other similariiistallations.
(1) Describe special emergency services that might be required.
No special emergency ser0ces will be required for this proposal.
(2) Proposed measures to reduce or control environmental health hazards, if any:
At this time, there have been no measures proposed to reduce or control emdronmental health
hazards.
b. Noise
(1) What types of noise exist in the area which may affect your project (for
example: traffic, equipment operation, other)?
There is not anj, existingnoise m the area that would affect this project.
(2) What types and levels of noise would be created by or associated with the
project on a short-term or a long-term basis (for example: traffic, construction,
operation, other)? Indicate what hours noise would come from site.
There will be nnnor shod -[elm noise associated uiti tie constiuction phase of die project.
There Tiill be no new significant noise associated ualh operation oftie project.
(3) Proposed measures to reduce or control noise impacts, if any:
T-Mobile will comply with all slate and local ordinances regn-dingnoise.
8. Land and Shoreline Use iS+ (-
C_�nGKr � Cheer �
a. What is the current use of the site and adjacent properties?
71 c subject propeayis used by the South King CountyFiie & Rescue as afire station. 77ie adjacenl
propellies accommodate coininercnl and residential.
b. Has the site been used for agriculture? If so, describe.
This properly has not been used for agiicullure.
T-Mobile
SE04693 Mirror Lake
SPPA Checklist - Page 8
c. Describe any structures on the site.
The fire station exists on the property.
d. Will any structures be demolished? If so, what?
No structures will he demolished.
e. What is the current zoning classification of the site?
The site is zoned RS 9.6 by the City of Federal Way Please see the Zoning Map in the SEPA
Exhibits for mole detailed information.
f. What is the current comprehensive plan designation of the site?
The City ofFederal Wayhas deemed this area Residential SI r101!�Q FaM��y9�
g. If applicable, what is the current shoreline master program��designation of the
site?
Not appEcable to this project.
g. Has any part of the site been classified as an "environmentally critical" area? If
so, specify.
T-Mobile and its agents are not aware of the suhject area for the proposal being classified as
"en nti onmentally serrsrt7Ve ".
i. Approximately how many people would reside or work in the completed
project?
The licilily is unmarmed. Orre (1) to two (2) employees are on -site for xi average offour (4)
hours of monthly manitenance checks. This check Is typically for preventim maintenance
purposes. In the erenl ol'a problem, a crewis dVpaldred to the site imrnediale#J
J. Approximately how many people would the completed project displace?
Tlris proiecl will nol displace any people.
k. Proposed measures to avoid or reduce displacement impacts, if any:
This project Trill nor displace anypeople, therefore no measures are needed to ar oid orreduce
displacement rmpacls.
T-Mobile
SE04693 Minor Lake
SEPA Checklist - Page 9
1. Proposed measures to ensure the proposal is compatible with existing and
projected land uses and plans, if any:
T-Mobile's additional a itennas are bens" attached to the existing tower next to their existing-
vutennas. Please see the enclosed photo simulations. Tlie antemras aurd associated mountirug-
lixdrnaue will be painted to match the existing tower to be as non-mtrusir e as possible.
9. Housing
a. Approximately how many units would be provided, if any? Indicate whether high,
middle, or low-income housing.
No units will be pro Tided by dris project.
b. Approximately how many units, if any, would be eliminated? Indicate whether
high, middle, or low-income housing.
No wets will be eliminated by this project.
c. Proposed measures to reduce or control housing impacts, if any:
Tlris project mill not impact housing, theuelbre uuo measures ve needed to reduce or control
housing impacts.
10. Aesthetics C p k\r W'h 04C*A%9� 4A _ G)
a. What is the tallest height of any proposed structure(s), not including antennas; what.
is the principal exterior building material(s) proposed?
The proposed additional antennas will be attached to die existing one -hundred ,wd 11f[y (150) loot
monopole torTer:
b. What views in the immediate vicinity would be altered or obstructed?
T-Mobile's additional vrtennas ve being attached to the existing monopole toner next to their
existing antennas.
The site will be risible; horremer die proposed location oldie liciAly does not impede riews olany
significant rierascapes such as die lake, mountain views, vrd/or mpxisime views. Please see die
enclosed Photo Simulations.
c. Proposed measures to reduce or control aesthetic impacts, if any:
T-Mobile's additional mrlemras ve being attached to die existing monopole louvr 11ex7 to dreiu-
existing antennas. Please see the enclosed Pliolo Simulations.
The anteumas and associated mountirrglixdware will be painted to match the existirugrnonopole to
blend with die sunoundingenrironment.
T-Mobile
SE04693 Mirror Lake
SEPA Checklist - Page 10
11. Light and Glare Con UV_ U, r),h 04g t%J ( - -4
a. What type of light or glare will the proposal produce? What time of day would it
mainly occur?
Generally, this proposal will not produce arrylight and/orglare.
b. Could light or glare from the finished project be a safety hazard or interfere with
views?
Generally, tlus proposal Kill not produce any light and/w-glare.
c. What existing off -site sources of light or glare may affect your proposal?
There are no existing oll=site sources of gllt orglare that will affect this proposal.
d. Proposed measures to reduce or control light and glare impacts, if any:
Generally, dus proposal H,7II not produce ujy light and/orgl u e impacts. 1
12. Recreation ,p h c" r W ►� a'&k� _C I
a. What designated and informal recreational opportunities are in the immediate
vicinity?
No recj eational opporlunities were noted in the immediate racinity oftre project.
b. Would the proposed project displace any existing recreational uses? If so,
describe.
This project r+ould not displace vey austingrecreational uses.
c. Proposed measures to reduce or control impacts on recreation, including
recreation opportunities to be provided by the project or applicant, if any:
This project mould not displace any evstingrecieatiomd uses, therefore no measures are needed to
reduce or control recreation oppor l unities.
13. Historic and Cultural Preservation C orLuAr w h r� R-c
a. Are there any places or objects listed on, or proposed for, national, state, or local
preservation registers known to be on or next to the site? If so, generally describe.
TMobile and its agents ve not ar w-c ofany places or objects listed on, or proposed for-, national,
state, or local preservation registers ImoTni to be on orneit to the project.
T-Mobile
SE, 04693 Mirror Lake
SPPA Cliecklist - Page 11
b. Generally describe any landmarks or evidence of historic, archaeological, scientific,
or cultural importance known to be on or next to the site.
T-Mobile vid its agents are not aware ofviy Ividmar*s, or ei4dence ol'bistwical, rrhaeological,
scienafic, or cultural importance to be on or next to die project.
c. Proposed measures to reduce or control impacts, if any:
T-Mobile's additional antelmas are being attached to die existing monopole tower -next to their
exisdugautennas. Please see the enclosed Plioto Simulations.
The vhtennas and associated mounting hardware will be painted to match the existing monopole
tower to blend with die surrounding environment
14. Transportation C"C4Ar 'nth
a. Identify public streets and highways serving the site, and describe the proposed
access to the existing street system. Show on site plans, if any.
The project is located o11'F Arse Soudi. (Please see Vicinity Map Exhibit)
b. Is site currently served by public transit? If not, what is the approximate distance to
the nearest transit stop?
Not applicable to this project.
c. How many parking spaces would the completed project have? How many would
the project eliminate?
On-sile paiking-bas been provided for maintenance vehicles.
c. Will the proposal require any new roads or streets, or improvements to existing
roads or streets, not including driveways? If so, generally describe (indicate
whether public or private).
This proposal Till not requil-e any nernroads or styeels.
e. Will the project use (or occur in the immediate vicinity of) water, rail, or air
transportation? If so, generally describe.
This is an umnanned facility wid will not require die use of water, 1wi1 or yr tMI)SpOl-1,7 011.
d. How many vehicular trips per day would be generated by the completed project? If
known, indicate when peak volumes would occur.
The facility will be ulmlvined. One (1) to two (2) ,u intenance visits permondi is eipected.
g. Proposed measures to reduce or control transportation impacts, if any.
There are no traffic impacts associated wadi these types of facilities as they are unmvnied and
require nifrequent maintenvice, therefore no measures are needed to reduce or control
transportation impacts.
T-Mobile
SE04693 Minor L.A-e
SEPA Checklist - Page 12
15. Public Services
can eu Y ,,a h 6,►sf (q ---b�
a. Would the project result in an increased need for public services (for example: fire
protection, police protection, health care, schools, other)? If so, generally describe.
This project will not result in 8n increased need for pubLc serrates.
b. Proposed measures to reduce or control direct impacts on public services, if any.
This project will not result in an increased need for public seiTaces, therefore no measures are
needed to reduce or control direct impacts on public services.
16. Utilities
tA,+k 0e0k1is*- [tea—Q
a. Underline utilities currently available at the site: electricity, natural gas, water,
refuse service, telephone, sanitary sewer, septic system, other.
Electricity.• Puget Sound Energy
Telephone: Verizon/QWest
b. Describe the utilities that are proposed for the project, the utility providing the
service, and the general construction activities on the site or in immediate N rlJt37
which might be needed.
Telephone serrate wall be proraded by tie local telephone company. Electrical power wall be
pvoraded by the local power prorader: Water-, sewer vrd natural gas ve not required 16r this
project.
Signature
The above answers are true to the best of my knowledge. I understand that the lead agency is
relying on them to make its decision.
.Slb°71aLr1r'C
August 21, 2012
Date
T-Mobile
SE04693 Minor LA-e
SEPA Checklist - Page 13
AERIAL -VICINITY MAP
PROJECT NAME: SE04693 Mirror Lk
PROJECT ADDRESS: 31617 lst Ave South
PROJECT PARCEL NUMBER: 0721049210
T-Mobile
SE04693 Mirror Lk
SEPA Checklist Exhibit
FEMA Map
LEGEND
ZONE X: Areas determined to be outside 500-year floodplain.
T-Mobile
SE04693 Mirror Lk
SEPA Checklist Exhibit
PARCEL MAP
PROJECT NAME: SE04693 Mirror Lk
PROJECT ADDRESS: 31617 1st Ave South
PROJECT PARCEL NUMBER: 0721049210
9013
W30
�
3
9029
9232
9242
TH
9074 S 315ST
9106 0140
9030
01W
0180
9019 9196
9198
Sw 316TH ST
0190
9011
07210492� �.1°
011a
v
F e
011n
d e va I.W. any
0290 0370
��
0300
0420 040a
9204
00i0
1{?,-
S ��
0020
0530
0450
0480 0520
0510
0090
9131
0440
0460
0410
0490 0550
U50a
0080
�
51V 313T N W
0100
{q
I RC I aa6{r
of 9133
9258
0130
q
(G01'2010 KiOOZO V
T-Mobile
SE04693 Mirror Lk
SEPA Checklist Exhibit
PROJECT NAME: SE04693 Mirror Lk
PROJECT ADDRESS: 31617 1st Ave South
PROJECT PARCEL NUMBER: 0721049210
T-Mobile
SE04693 Mirror Lk
SEPA Checklist Exhibit
19807 North Creek Parkway North
Bothell, WA 98011
City of Federal Way - Planning
33325 8th Ave. South
Federal Way, WA 98003
Re: T-Mobile - SE04693 Mirror Lake - 31617 1 st Ave South
T-Mobile agrees to allow for the potential collocation of additional PWSF equipment by
other providers within the same site location. T-Mobile acknowledges that if an applicant
contends that future collocation is not possible on their site, they must submit a technical
study documenting why (FWRC 19.255.060121).
Maria Emig
Print N ine
�J
Signature
Development Manager
Print Title
6/6/2012
Date
RECEIVED
AUG 292012
CITY OF FEDERAL WAY
CDS
Rebecca Chapin
From: Rebecca Chapin
Sent: Tuesday, September 04, 2012 10:30 AM
To: 'azike@realcomassoc.com'
Subject: T-Mobile - SE04693 Mirror Lake - Preapp Waiver
Hi Allison,
The City received your request for Preapplication meeting waiver, received August 30, 2012. Per Federal Way Revised Code
19.40.030(2)(a), due to the simple nature of the proposal, and because the site has previously undergone a site plan review for a
similar development proposal, your request for waiver of the required preapplication conference is hereby approved. Please be advised
that this waiver of preapplication review may increase the risk of the application being incomplete or that the processing time will be
increased.
I will continue to review the UPIII application and SEPA checklist and let you know if there questions or comments. Feel free to contact
me if you have any questions regarding this project.
Thanks,
Becky Chapin
Assistant Planner
Community and Economic Development
City of Federal Way
33325 8th Avenue South
Federal Way, WA 98003-6325
Phone:253-835-2641
Rebecc a. C h a pi n aRcityoffederalway.com
1
RE L C 0 M
August 30, 2012
City of Federal Way - Planning
33325 8th Ave. South
Federal Way, WA 98003
Re: T-Mobile - SE04693 Mirror Lk - Pre -Application Waiver Request
Dear Federal Way Planning Department:
Please accept this letter as T-Mobile's request to waive the pre -application meeting for the
proposed site modifications at the SE04693 Mirror Lake site located at 31617 1st Ave
South, Federal Way, Washington (Parcel No. 1321039062).
Respectfully,
Allison Zike
Agent for T-Mobile
RECEIVED
AUG 3 0 2012
CITY OF FFOFRgL WAY
CDs
RealCom Associates, LLC
14432 SE Eastgate Way, Suite 260 P 8ellevue,Washington 98007 Phone (425) 274-4444.S;Fax (425) 274-4449
www.realcomassoc.com
RECEIVED MASTER LAND USE APPLICATION
9 qO�q DEPARTMENT OF CONmiuNITY DEVELOPMENT SERVICES
2 L L 33325 8`h Avenue South
CITY OF �` _ "� Federal Way, WA 98003-6325
Federal Wav CITY OF FEDERAL WAY 253-835-2607: Fax 253-835-2609
CDs tvww.61yPlTedt ra1w;tvxvm
APPLICATION NO(S) 1 ~ 1 a 410 V W v? - 1 v11( 01S- Date ,� 1 1 k4--
Project Name
T-Mobile - SE04693 Mirror Lake
31617 1 st Ave South
Property Address/Location
0721049210
Parcel Number(s)
Modify existing telecommunication facility by upgrading/replacing six (6) existing
antennas Project Description B
w antennas.
PLEASE PRINT
Type of Permit Required
_ Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
_ Land Surface Modification
_ Lot Line Elimination
Preapplication Conference
Process I (Director's Approval)
Process II (Site Plan Review)
II Process III (Project Approval)
Process IV (Hearing Examiner's Decision)
Process V (Quasi -Judicial Rezone)
_ Process VI
SEPA w/Project
SEPA Only
_ Shoreline: Variance/Conditional Use
Short Subdivision
_ Subdivision
Variance: Commercial/Residential
Required Information
RS-9.6 Zoning Designation
Comprehensive Plan Designation
Value of Existing Improvements
$30,000 Value of Proposed Improvements
International Building Code (IBC):
Telecom ELOccupancy Type
Telecom Construction Type
Applicant
Name: T-Mobile
Address: 19807 North Creek Parkway North
City/State: Bothell, WA
Zip: 98011
Phone:
Fax:
Email:
Signature:
Agent (if different than Applicant)
Name:
RealCom Associates - Allison Me
Address:
14432 SE Eastgate Way, Suite 260
CitylState:
Bellevue, WA
98007
7.i : p
Pp:
(425) 274-4444 ext. 112
Fax:
(425) 274-4449
Email:
azike@realcomassoc.com
Signature:
Owner
South King County Fire & Rescue
Name:
Address:
31617 1 st Avenue South
city/state:
Federal Way, WA
Zip:
98003
Phone:
(253) 839-6234
(253) 529-7204
Email:
Signature;
1.
_;� ��
Bulletin #003 — January 1. 2011 Pale I of 1 k:\Hand0utsVN4as1er Land Use Application
d
VICINITY MAP
�
son
%.
a 4a Sw 308BI St -FFiriw ukr
N
SITE Lgg4TJON
�a towk
n
F+
K5
y a
a
4
FedenlYry
to
S 3171A U
a
V
SW 390V+ St 5 .zm St.
9q
`t y SIh PI. N N
ZS
1p
3:
LEGAL DESCRIPTION
PCL B OF FEDERAL WAY LLA #BLA95-0011 REC #9610289005 SO LLA
LOCATED IN NE 1/4 OF BE 1/4 OF SE 1/4 OF SEC 7-214 LESS FOR FOR RD
APPROVAL/SIGN OFF OF DRAWINGS
CONSULTANT GROUP SIGN OFF
DATE
INITIAL AND PRINT NAME
LANDLORD'S REPRESENTATIVE
CONSTRUCTION COORDINATOR
PROJECT MANAGER
SITE ACQUISITION
ZONING
RF ENGINEER
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
T Mobile •'
MIRROR LAKE/C I N G U LAR/KC FIRE
31617 1 st AVENUE S
FEDERAL WAY, WA 98003
KING COUNTY
S E 04693A
LATITUDE 470 19' 07.3" N LONGITUDE 1220 20' 09.6" W
AT&T TOWERS #: 11602-A
GENERAL LOCATION MAP
1 f iW►A
SITE LOCATION
I -all
,N mw
1 • r .�� � � w 4 If t• �e.r :.
1
DRIVING DIRECTIONS
FROM T-MOBILE BOTHELL OFFICE:
HEAD TOWARD NE 195th ST ON NORTH CREEK PKY, GO 0.2 MI
TURN RIGHT ONTO NE 195th ST, GO 0.3 MI
TURN LEFT AND TAKE RAMP ONTO 1-405 S TOWARD RENTON, GO 24.3 MI
CONTINUE ON WA-518 W, GO 521 FT
TAKE THE 1-5 &PORTLAND EXIT ONTO 1-5 S. GO 10.6 MI
TAKE EXIT #143/FEDERAL WAY/S 320th ST, GO 0.3 MI
TURN RIGHT ONTO S 320th ST. GO 1.6 MI
TURN RIGHT ONTO 1st AVENUE S, GO 0.2 MI
YOUR DESTINATION ON 1st AVENUE S. IS ON THE LEFT
THE TRIP TAKES 37.7 MI & 43 MINS
PROJECT TEAM
APPLICANT:
PROGRAM MANAGEFL
T-MOBILE
REALCOM ASSOCIATES
19807 NORTH CREEK PARKWAY
MATT CAGAN
BOTHELL, WA 98011
(206) 948-3408
CONSULTING ENGINEER:
CONSTRUCTION PROJECT MANAGER:
CORNERSTONE ENGINEERING, INC.
REALCOM ASSOCIATES
16928 WOODINVILLE REDMOND ROAD NE SUITE 210
JULIA RUZON
WOODINVILLE, WA 98072
(206) 604-1895
MARK W OLSON, P.E.
CONSTRUCTION COORDINATOR:
PH: (425) 487-1732
FAX: (425) 487-1734
REALCOM ASSOCIATES
JULIA RUZON
PROJECT CONSULTANT:
(206) 604-1895
REALCOM ASSOCIATES
14432 SE EASTGATE WAY, SUITE 260
SITE ACQUISITION:
BELLEVUE, WA98007
REALCOM ASSOCIATES
FAX: (425) 2744449
NANCY SEARS
(425)444-1434
PROPERTY OWNER:
FIRE DISTRICT #39 712777
ZONING:
31617 1st AVENUE S
REALCOM ASSOCIATES
FEDERAL WAY, WA 98003
SARAH TELSCHOW
(425) 274-4444 EXT. 114
ER OWNER:
TOWER
stelschow@realcomassoc.com
6100 ATLANTIC BLVD
RF ENGINEER:
NORCROSS, GA30071
T-MOBILE
DARRYL SALK
(425)770-0006
PROJECT INFORMATION
CODE INFORMATION:
PARCEL NUMBER:
ZONING CLASSIFICATION: RS9.6
0721049210
BUILDING CODE: IBC 2009
AREA OF PARCEL:
CONSTRUCTION TYPE: II-B NON-COMBUSTIBLE
±87,120 SQ. FT. (2.0 ACRES)
JURISDICTION: FEDERAL WAY
PROPOSED BUILDING USE: TELECOMM
PREVIOUS PERMIT APPROVALS:
FWHE 98-07, UP4-98-0001,
& 04-102732-00-CO
GENERAL INFORMATION:
1. PARKING REQUIREMENTS ARE UNCHANGED. (NON ASSIGNED TECH PARKING)
2. TRAFFIC IS UNAFFECTED.
3. NO SIGNAGE IS PROPOSED.
PROJECT DESCRIPTION I
THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY, CONSISTING OF THE REMOVAL/REPLACEMENT OF (6)
EXISTING ANTENNAS AND ADD (3) NEW ANTENNAS WITH TOTAL OF (9) NEW TMaM-6516 UM
ANTENNAS; ALSO THE ADDITION OF (2) FXFB UNITS, (3) FRIG UNITS AND COLLAR MOUNT TO AN
EXISTING MONOPOLE; ALSO THE ADDITION OF (1) HYBRID CABLES, (2) COVP UNITS (1 NEAR
ANTENNAS AND 1 NEAR THE SITE SUPPORT EQUIPMENT) ON AN EXISTING CONCRETE SLAB
WITHIN AN OPEN-AIR SHELTER.
RECEIVED
AUG 292012
CITY OF FEDERAL WAY
CDS
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR
DISCLOSURE OTHER THAN THAT WHICH RELATES TOT -MOBILE
WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED.
DRAWING INDEX
DWG
DESCRIPTION
T-1
TITLE SHEET
G-1
GENERAL NOTES
A-1
SITE PLAN
A-1.1
EXISTING ENLARGED SITE PLAN
A-1.2
I PROPOSED ENLARGED SITE PLAN
A-2
SOUTH ELEVATION
A-2.1
PROPOSED NORTH, EAST & WEST ELEVATIONS
A3
DETAIL SHEET
A3.1
DETAIL SHEET
E-1
SCHEMATIC GROUNDING PLAN & DETAILS
RF-1
RF DETAILS
RF-2
RF DETAILS
PROJECT INFORMATION I
THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND WILL BE
USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE
PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. T-MOBILE
CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE
SERVICED ONLY BY T-MOBILE EMPLOYEES AND THE WORK
ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY
HANDICAPPED PERSONS. THIS FACILITY WILL BE FREQUENTED
ONLY BY SERVICE PERSONNEL FOR REPAIR PURPOSES. PURSUANT
TO THE AMERICANS WITH DISABILITIES ACT (ADA), APPENDIX B
SECTION 4.11. (5) (B), THIS FACILITY IS EXEMPT FROM THAT ACT.
NO POTABLE WATER SUPPLY TO BE PROVIDED AT THIS LOCATION
NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS
LOCATION.
T-MOBILE MAINTENANCE CREW (ONE PERSON) WILL MAKE AN
AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER TRIP.
CALL TWO WORKING DAYS BEFORE YOU DIGI
It 811
NATIONAL UTILITIES UNDERGROUND LOCATE
E,ecrwc-eED rv-awWDe
SKEIVPNETDRPQBHMLE�PIHB�IEDeY SEWER-DREEN IroSED-WNDE
cama�CTDpyxhn.n.we E. c,,sai�-�w�rc w�TEa-EwE
T - Mobile
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
�� �crwpigh1�18TCN8
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 9W72
PHONE: 425X: .487.1732 FA425.487.1734
EMAIL: mi@wmemtone-engnwm
W W W.CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR —
CCONSTRUCTION
�REV::DATE: =ISSUED FOR: BY:
DRAWN BY:=CHK.: APV.:'
JRF DRA MWO
=CURRENT ISSUE DATE:
I Ir'ChICI lGF• 08-16-12
B ue(t-L
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORSAND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARESUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTIHNM IN THIS SET OF DOCUMENTS
IS PROPRx tARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
57RK:TLYPROH113rrED
TITLE SHEET
:DRAWING NUMBER:
T-1
0
CEI JOB NUMBER:
12-06007
GENERAL NOTES:
1. DRAWINGS ARE NOTTO BE SCALED.WRI TTIIN DIMENSIONS TAKE PRECEDENCE, THLSSET OF
DCCLPMENTS 15 WTENOED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS NOTED
OTHERWISE- THE GENERAL CONTRACTORS SCOPE OF WORK SHIALL INCLUDE FURNISHING ALL
MATERALS, SOUIPMENT, LABOR, AND ANY REQUIREMENTS DEEMED NECESSARY TO COMPLETE
PROJECT AS DESCRIBED IN THE DRAWINGS AND DINNER'S PROJECT MANUAL
2. PRIOR TO THE SUBMISSION OF II CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO
FAMILLLMZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT.
CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTIONICONTRACI
DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WIL HE
AGGDMPLISHEDAS SHOWN. FRIORTO PROCEEDING WITH CONSTRUCTM. ANY ERRORS.
OMISSIONS, CR DISCREPANCIES SHALL BE BROUGHT 70 THE ATTENTION OF THE
ARCHITECT/ENGINEER VERBALLY AND IN WRITING.
3. THE AFICHITECTWENGIWEPS HAVE MADE EVERY EFFORTTO SET FORTH 9N THE CONSTRUCTION
AND CONTRACT OOCUMENM THE COMPLETE SCOPE OF WORK. CONTRACTORS SIODWG THE JOB
ARE NEVERTHELESS CAVTI0NE0 THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR
SPECIFICATIONS SHALL NOT E=)SE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND
IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS- THE BIDDER SHALL
BEAR THE RESPONSIBILITY OF NOTIFYING ON WRITOHI)THE ARC>-BTEi7+ENGINEERAFANY
CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO S1IBMISSIQN OFCOFTLRACTOR'S PROPOSAL. IN
THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE
WORK UNLESS DIRECTED OTHERWISE.
4. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT
DOCUMENTS- THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION
MEANS, METHODS, TECHNIQUES. SEQUENCES, AND PROCEDURES FOR COORDINATING ALL
PORTIONS OF THE WORK UNDER THE CONTRACT.
S. THE CONTRACTOR SHALL IN STALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'S /t;NDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL
CODES OR ORDINANCES TAKE PRECEDENCE.
6 ALL WORK PERFORMED ON IMF PROJECT AND LATERALS INSTALLED SHALL. BE IN STRICT
ACCORDANCE WTHALL APPLICABLE CODES, REGULATIONS. AND ORDINANCES. CONTRACTOR
WILL GIVE ALL NOTICES ANO COMPLY VATS ALL LAWS. ORDINANCES, RULES. REGULATIONS AND
LAWFUL. ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS,
AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE Wow
7. GENERA, CONTRACTOR SHALL PROVIDE. AT THE PROJECTSITE, A FULL SET OF CONSTRUCTION
DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE
BY ALL PERSONNEL INVOLVED WITH THE PROJECT- THIS SET IS A VAUDCONTITACT DOCUMENT
ONLY IF THE TITLE SHEET IS STAMPED TORCONSTRUCTK)N'AND EACH SUOCESSNESHEET
BEARS THE ARCHITECTS SIGNED WET STAMP
8. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE
ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE.
9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL
APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE
10 CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING OFNOT LESS THAN
2-A OR 2"A1 BBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING
CONSTRUCTION
11. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT E)OSTING IMPROVEMENTS,
EASEMENTS, PAYING, CURSING, ETC- DURING CONSTRUCTION. UPON COMPLETION OF WORTS
CONTRACTORSHALL REPAIR ANY DAMAGE THATMAY HAVE OCCURRED DUE TO CONSTRUCTION
ON OR ABOUT THE PROPERTY.
12 CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING
CONSTRUCTION ANO DISPOSE OF ALL GIRT, OEBRi%AND RUBBISH. CONTRACTORSHALL REMOVE
ECUiPWENTNDT SPEGFIEO AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT
IN CLEAN COF401TEON AND FREE PROM PAINT SPOTS. DUST, OR SMUDGES OF ANY NAIJRE
13 THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH
CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE
CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
14. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID
DISTURBING NORMAL BUSINESS.
15 THE CONTRACTOR SHALL PROVIDE THE CLIENT PROPER INSURANCE CERTIFICATES NAMING
CLIENTAS ADDMONAL INSURED, AND CLIENT ALOOF OF LICENSE(S) AND PE & PD INSURANCE.
16 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS.
17 CAUTIONI CALL BEFORE YOU DIG? BURIED UHLITIES EXIST IN THE AREA AND UTILITY INFORMATION
SHOWN MAY NOTEE COMPLETE. CONTACT THE ONE -CALL UTL17Y LOCATE SERVICE A MINIMUM OF
48 HOURS PRIOR TO CONSTRUCTION DIAL B11
18 CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO CLIENT
ALONG WITH RECLINED CONSTRUCTION SET.
19 CONTRACTOR TO DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP(R.EDLINING) THE
APPROVED CONSTRUCTION SET AND SUBMITTING THE RECLINED SET TO THE CLIENT UPON
COMPLETION
20 FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID
WALK
21. GENERAL CONTRACTOR $ TQ COORDINATE ALL POWER INSTAL ATLON WITH POWER COMPANY AS
REQUIRED. CONTRACTOR TO REPORT POVVM INSTAUATp)NCOOROINA7MN SOLUTLON[S)TO
NETWORK CARRIER REPRESENTATIVE. PROJECT CONSTRUCTION MANAGER AND ARCHITECT,
22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY CLIENT
CONSTRUCTION MANAGER
23 IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AJNDIDR ANTENNA FRAMES WHERE
PENETRATION OF EXISTING ROOFING MATERIALS OCCUR THE GENERAL CONTRACTOR SHALL
COORDINATE YWTH BUILDING OWNER AND SO HLOING ROOFING CONTRACTOR OF RECORD FOR
INSTALLATION, PATCH. REPAIR OR ANY AUGMENTATION TO THE ROOF. AND RAVE THE WORK
GUARANTEED UNDER THE ROOFING CONTRACTORS WARRANTY FOR MOETURE PENETRATION OR
AND OTHER FUTURE BREACH OF ROOFING INTEGRITY.
24. IN THE CASE OF ROOFTOP SOLUTIONS WRNS THE INSTALLATION OF ANTENNAS WITH IN CONCE&FD
(SHROUDT DOMPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE
WITH THE FRP DES?GNFJLFABRJCATORTo ENSURE THATTHE FINAL FRP SHROUD IS SIMULATING PN
APPEARANCE)OESIGNATED EXISTLHG EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, ASO
COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK
FASTENERS IN ALL FRP CONSTRUCTION, WHEN PHOTO SIMULATIONS ARE PROVIDED. THE
CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT 15 INDICATED IN
PHOTO SIMULATIONS. SHOP DRAWNGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR
CONSTRUCTION COORDINATOR AND ARCHITECT PRIOR TO FABRICATOR AND CONSTRUCTION.
GENERAL NOTES [CONTU ,
25. IN THE CASE OF ROOFTOP SOLUTIONS MR EQUIPMENT ANDIOR ANTENNA FRAMES WHERE
ANCHORING 70ACONCRETE ROOF SLAB IS REQU IREO, CONTRACTORS SHALL CONFIRM (FIN ORTO
SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE
PRESENCE OF POST TENSION TENDONS WITHIN THE RODFSLAB - RESULTING FROM AN
UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING'ASEUB-T DRAWING SET'- HAVING
INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE WJ EMBEDDED STEEL
REPAR IN THE EYENT POST TENSION SLAB SOLUTION IS PRESENT. CONTRACTOR SHALL INCLUDE
PROVISIONS FOR X.RAY PROCEDURES (INOLUCED IN MID) FOR ALL PENETRATM NAREAS VWERE
ANCHORING OCCURS
26. GENERAL d SUB CONTRACTDRS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL
CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE OOWNNS (WHERE APPLICABLE) PLASTIC ZIP
TIES SHALL NOTEE PERMITTED FOR USE. ON CLIENT PROJECTS- RECOMMENDED MANUFACTURE
SHALL BE PANDUIT TARP, METAL LOCKING TIES MODEL NO. MLT4S4,P UNDER SERIES-304(OR
EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRAM OF TACO A. WA
DESIGN CRITERIA:
1- THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL
BUILDING CODE 2009 WITH WASHINGTON STATE BUILDING CODE AMENDMENTS (IBC 2009)
2. DESIGN EOADS
DESIGN DATAFOR FEDERAL WAY, WA:
-ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION)
-BASIC WIND SPEED 85 MPH (3 SEC GUST)
-WIND EXPOSURE B
CODE COMPLIANCE:
ALL WORK AND MATERIALS SHALL BE PERFORMED ME) INSTALLED IN ACCORDANCE WITH THE
CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED SY THE LOCAL GOVERNING AIJTHOMTIES.
NOTHING ON THESE BANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT OCNFCALMING TO THESE
CODES:
2009 INTERNATIONAL BUILDING CODE 2" INTERNATIONAL RESIDENTW. CODE
2008 INTERNATIONAL MECHAN[CAL CODE 20M INTERNATIONAL FUEL GAS CODE
20M NFPA 54- NATIONAL FUEL GAS CODE 2009 INTERNATIONAL FIRE CODE
(PROPANE INSTALLATIONS ONLY} 200E UNIFORM PLUMBING CODE
20P9 NFPA58-LROUEIED PETROLEUM GAS CODE Y008 WPA TO NATIONAL ELECTRICAL CODE
(PROPANE INSTALLATIONS ONLY) mu NATKWAL ELECTRIC SAFETY CODE
LOCAL BUILDING CODE ORDINANCES 2W9 ANSI ITA. /ETA-T33-G
2009 WASH INGTON STATE ENERGY CODE NFPA-101 - LIFE SAFETY CODE
ICC/ANSI Al 17.1-20M
2009 INTERNATIONAL EXISTING BUILDING CODE WITH STATE WIDE AMENDMENTS FOUND IN THE IBC
CONCRETE NOTES:
1 ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI316
2 CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH
CHAPTER 19 OF THE IBC 2009. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS.
TYPE OF CONSTRUCTION 28 DAY STRENGTHS W/C MINIMUM CEMENT
TO RATIO CONTENT
A. SLABS ON GRADE PERCUBIC YARC
TOPPING SLABS
CONCRETE PIERS 3,000 PSI 1 45 5112 SACKS
B. ALL STRUCTURAL CONCRETE 4,000 PSI '_ .45 612 SACKS
EXCEPT WALLS
C CONCRETE WALLS 4.000 PSI ` AS 612 SACKS
CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U N O.
3 THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND
PROCEDURES OF CONCRETE PLACEMENT
4. ALL CONCFZMWTH SURFACES ELPOSEDTOSTANDING WATER SHALL BE AIR -ENTRAINED WITH
ANANR.ENTRAINING AGENT CONFORMING TO ASTM C26D,C494,G8IM CABS AND C1017. TOTALAIR
CONTENT SHALL BE IN ACCORDANCE WITH TABLE IW2.1 OF THE IBC 2009.
5, RHNFORCIW STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT Sl] GRADE B0.
6-iADDD PSI, EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE ORAWINGSSW BE
GRADE 4%f1 .000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED
SHALL CQIIFORM TOALSTM AT06 REINFORCINGDOMPLYING WITH ASTM A616(S1) MAYBE WELDED
ONLY IP MATIII PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES
SPECIFIED IN A.W.S. D14 ARE SUBMITTED,
6. REINFORCING STEEL SWILL BE CETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH
ACI315AND 31d. LAP ALL CONTINUOUS REINFORCEMENT AT LEAS( 30 EAR DIAMETERS ORA
MINIMUM OF T{Y. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP
CORNER SARSAT LEAST 30 BAR DIAMETERS ORA MINIMUM OFV-W. LAPAWACENTMATS OF
WELDED WIRE FABRIC WNLMUM OF If' AT SIDES AND ENDS-
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185
8 SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy- 0,000
PSI
9 NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS
SPECIFICALLY SO DETAILED OR APPROVED BYTHE CONSULTANT.
10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
3-
FOOTINGS AND OTHER UNFORMED
SURFACES, EARTH FACE
(#6 BARS OR LARGER) 2'
FORMED SURFACES EXPOSED (#5 BARS OR SMALLER) 1 12'
TO EARTH OR WEATHER
3/4'
11 SLABS AND WALLS (INTERIOR FACE)
12 BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS.
13 ANCHOR BOLTS TO CONFORM TO ASTM A307.
14. NON -SHRINK GROUT SHALL BE R)RNISHED BY AN APPROVED MANUFACTURER AND SHALL BE
MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURERS PUSUSHED
RECOMME HOATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH
IT IS PLACED (3,000 PSI MINIMUM)
15 ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS REQUIRE TESTING TO
CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER
STRUCTURAL STEEL NOTES:
1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR
REVIEW PRIOR TO FABRICATION.
2 STRUCTURAL STEEL OESIGN. FABRICATION AND ERECTIDN IINCLUDING F1 ELO WELDING RICH
STRENGTH FIELD SOLTING. EXPANSION BOLTS. AND THREADED F)WANSION ANCHORS)SHALL BE
BASED OR THE AI-W, *SPECIFICATION FOR THE %SIGN. FABRICATION, AND ERECTION OF
STRUCTURAL STEEL FOR SWLDINGS' LATEST EDITION. SUPERVISION SHALL BE INACCORWNCE
WITH ISC 2DO9 CHAPTER ZZ BY A QUALIRED TESTING AGENCY DESIGNATED BY THE CONSULTANT.
THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTSIW0 TEST
RESULTS
3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER
A WIDE FLANGE SHAPE ASTFA AV2. Fy 50 KSI
B. OTHER SHAPE, PLATES AND ROD ASTM A36, Fy 36 KSI
C. PIPE COLUMNS ASTM A53, Fy 35 KSI
D STRUCTURAL TUBING ASTM A500, Fy 46 KSI
E. ANCHOR BOLTS ASTM A307
F. CONNECTION BOLTS ASTM A325
4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00.
5 ALL WELDING SHALL BE IN CONFORMANCE WITH. A.LSJ.AND AWS STANDARDS AND SHALL BE
PERFORMED BY WA6-0, CERTIRED WELDERS USING Em XX ELECTRODES. ONLY PREOUAURED
WELDS (AS DEFINED BY AVIS) SHALL BE USED, WELDING OF GRADE WREINFORCING BARS (IF
REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELCM OF GRADE 40
REINFORCING EARS OF REGUIREO) S ALL BE PERFORMED USING E713 XX ELECTRODES- WELDING
WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE
FOR MATERIAL REQUIREMENTS OF WELDED BARS
6. COLO•FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE. AND C-bv SHOWN ON
THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL
FRAMING SHALL CONFORM TO THE A.LS-I. 'SPECIFICATION FOR THE DESIGN OF COLD -FORMED
STEEL STRUCTURAL MEMBERS.'
7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4' DIA) AND SHALL HAVE A
MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE.
8 NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8' DA ASTM A307 BOLTS
UNLESS NOTED OTHERWISE
9 ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN S CONSTRUCTION
SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS FITTED OTHERWISE.
10 ALL WELDS TO BE 1/4' FILLET UNLESS NOTED OTHERWISE.
11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR
APPROVED EQUAL.'
TOWERlPOLE NOTES:
1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA
LOADING IS TO BE DONE BY OTHERS
2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INFRAL AND
FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT
THE CENTERS SUITABLE TO THE MANUFACTURERS REQUREMEMS.
ABBREVIATED ROOFTOP SAFETY PROCEDURES
(WHEN APPLICABLE
(AS PER'ACCIDENT PREVENTION PROGRAM' BY PERMISSION OF WREN CONSTRUCTION, INC.-03ID1199)
FALL PROTECTION METHODS AND EQUIPMENT
ROOFTOP INSTALLATIONS
1. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE
CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE THE
MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS.
2 SAFETY MONITOR SHALL WARR CONSTRUCTION WORKERS OF HAZARDS (LE, BACKM UP
TOWARD ROOF EDGE, ETC.)OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON THE
SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CON5TM?CTICN WORKERS.
3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN V OR LESS OF AN UNPROTECTED
ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE
4, SAFETY LINE SHALL BE MINIMUM W DIAMETER NYLON, WITH A NOMINAL TENSILE STRENGTH OF
5400 LBS,
S. SAFETY LINE SHALL BE ATTACHED TOASUBSTANTAL MEMBER OF THE STRUCTURE
6- SAFETY LINE LENGTH SHALL BE SETALLOWING CONSTRUCTION WORKERTO REACH EDGE OF
ROOF, BUT NOT BEYOND.
7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS.
8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL
OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, INCLUDING:
INSPECTION OF CONSTRUCTION AREA FOR HAZARDS
USE OF AN INSPECTION CHECKLIST
INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS
REPORTING AND DOCUMENTING ANY HAZARDS
REPORTING HAZARDS TO THE SAFETY CG',1MITIEE FOR CONSIDERATION
POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN
RECEIVING AN UNBIASEO REVIEW OF ONES OWN WORK AREA BY ANOTHER COWORKER SAFETY
REPRESENTATIVE
REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL
NATIONAL ASSOCIATION OF TOWER ERECTORS MOO PUBLICATION
REFERENCED OSHA REGULATIONfVANDAROS SHALL BE REVIEWED BY TOWER ERECTORS,
EQUIPMENT INSTALLERS,ANO TOWSR.0ROOF TCP CONTRACTQRSIRMOCNTRACTURB
29 CFR 192G.S00- SCOPE, APPLICATION, AND DEFINITIONS
29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION
19 CFR 1926.502- FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
SYN.
)LS AND ABBREVIATIONS
A/C
AIRCONDITIONING
MAX
MAXIMUM
AGL
ABOVE GRADE LEVEL
MECH
MECHANICAL
APPROX
APPROXIMATELY
MTL
METAL
MFR
MANUFACTURE
BLDG
BUILDING
MGR
MANAGER
BLK
BLOCKING
MIN
MINIMUM
B.C.
BOTTOM OF
MISC
MISCELLANEOUS
B.C.S
BOTTOM OF STEEL
N/A
NOT APPLICABLE
CLG
CEILING
NIC
NOTINCONTRACT
CLR
CLEAR
N.S.
NEARSIDE
CMU
CONCRETE MASONRY UNIT
NTS
NOT TO SCALE
CONC
CONCRETE
CONST
CONSTRUCTION
O.C.
ON CENTER
CONT
CONTINUOUS
O.D.
OUTSIDE DIAMETER
OM
OVERHEAD
DBL
DOUBLE
DOJO
DIAMETER
PLCS
PLACES
D NAG
DIAGONAL
PLYWD
PLYWOOD
ON
DOWN
PROJ
PROJECT
DET
DETAIL
PROP
PROPERTY
DWG
DRAWING
PSF
POUNDS PER SQUARE FOOT
PSI
POUNDS PER SQUARE INCH
EA
EACH
PT
PRESSURE TREATED
EL
ELEVATION
ELEC
ELECTRICAL
RAD
RADIUS
EQ
EQUAL
REQ
REQUIRED
EQUIP
EQUIPMENT
RM
ROOM
E W
EACH WAY
RO
ROUGH OPENING
EXT
EXTERIOR
SCH
SCHEDULE
RN
FINISH
BHT
SHEET
FLUOR
FLUORESCENT
SIM
SIMILAR
FUR
FLOOR
SPEC
SPECIFICATION
F.S.
FARSIDE
SF
SQUAREFOOT
IFT
FOOT
SS
STAINLESS STEEL
STL
STEEL
GA
GAUGE
STRUCT
STRUCTURAL
GALV
GALVANIZED
STD
STANDARD
G.C.
GENERALCONTRACTOR
SOFT
SQUAREFOOT
GRND
GROUND
SO IN
SQUARE INCH
GYP BD
GYPSUM WALL BOARD
SUSP
SUSPENDED
HORZ
HORVANTAL
THK
THICK
HR
HOUR
THRU
THROUGH
HT
HEIGHT
TNNG
TINNED
HVAC
HEATING VENTILATION
T.O.
TOP OF
AIRCONDITIONING
T O S.
TOP OF STEEL
TYP
TYPICAL
I.D.
INSIDE DIAMETER
IN
INCH
UNO
UNLESS NOTED OTHERWISE
INFO
INFORMATION
INSUL
INSULATION
VERT
VERTICAL
NT
INTERIOR
V I F�
VERIFY IN FIELD
IBC
INTERNATIONAL BUILDING CODE
w/
WITH
LBS
POUNDS
W/O
WITHOUT
WP
WATER PROOF
R PLATE CHAIN -LINK FENCE
WOOD FENCE
fE CENTERLINE - T T - TELEPHONE
(E) EXISTING - P P - POWER
___---------- GROUNDWIRE
X DETAIL NUMBER WAX COAXIAL CABLE
Xi SHEETNUMBER
SPECIAL INSPECTIONS:
SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2009 SECTION 1704.
SOILWGEOTECHNIcAL:
❑SHORING INSTALLATION AND MONITORING
[]OBSERVE AND MONITOR EXCAVATION
❑VERIFY SOIL BEARING psi BEARING
❑SUBSURFACE DRAINAffE_ —PLACEMENT
❑VERIFY FILL MATERIAL AND COMPACTION
❑VERIFY CONDITIONS AS ANTICIPATED
❑PILE PLACEMENT (AUGER CASTIDRIVEN PILE)
❑OTHER
REINFORCED CONCRETE:
❑REINFORCING STEEL AND CONCRETE PLACEMENT
OPRESTRESSEDIPRECAST CONCRETE FABRICATION AND ERECTION
❑BATCH PLANT INSPECTION
❑SHOTCRETE
❑GROUTING
❑OTHER
STRUCTURAL. STEEL:
❑FABRICATION AND SHOP WELDS
❑ERECTION AND FIELD WELDS AND BOLTING
❑OTHER
STRUCTURAL ALUMINUM:
❑FABRICATION AND SHOP WELDS
❑ERECTION AND FIELD WELDS AND BOLTING
❑OTHER
STRUCTURAL MASONRY:
❑CONTINUOUS
❑PERIODIC
OTHER: NONE REQUIRED
ANCHORING TO CONCRETE:
[]BOLTS INSTALLED IN CONCRETE
❑POSTANSTALLATION ADHESIVE ANCHORS
❑POST -INSTALLATION MECHANICAL ANCHORS
T • Mobile•0
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
`PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
4 &--pp
NERSTONE
. q ... N.. INC.
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425 487 1732 FAX:425.4871734
EMAIL: cel@wmemt0n ngr.mm
W W W.CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR:
CCONSTRUCTION
=REV:: DATE: =ISSUED FOR: SY:--I
L DRAWN BY:-CHK.: APV.:"
JRF DRA MWO
CURRENT ISSUE DATE:
L08-16-12
I INCMICI ICI=• _
�DRAWIN[i INf•VKMAIIUN:
OO NOT SCALE DRAWINGS. CONTRACTOR MUSTWRIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF719S
DRAWING ARE SUPERSEDED BY THE LATEST REVISION,
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLEAT IS
STRICTLY PROHIBRFD,
DRAWING TITLE:
GENERALNOTES
DRAWING NUMBER:
G-1 0
CEI JOB NUMBER: 12-06007
THIS IS NOT A SURVEY
ALL INFORMATION AND TRUE NORTH
HAVE BEEN OBTAINED FROM EXISTING
DRAWINGS AND ARE APPROXIMATE.
(E) GRAVEL WALKWAY ACCESS
(E) GRAVEL ACCESS RD - ,
7
A•1.1
(E) ASPHALT
PARKING LOT
TL#:0721049017
SITE PLAN
22x3a SCALE: 1" =,W4r 11x17 SCALE: 1" -- 40'-C"
[
(
[
! I
FRENCH LAKE PARK
I
TL#:0721049014
(E) T-MOBILE 141-0"x2(r-(r
WOOD FENCE ENCLOSURE
I
(E) t150'-0" HIGH STEEL MONOPOLE
WI PROPOSED REPLACEMENT &
NEW ANTENNAS TMBXX-65184R2M
�• _ �_� _ _ —_ PROPERTY LINE S88" 47' 53" E (t351.22')
- - A-2 o a • Y ..
(E) BUILDING
(FIRE STATION)
(E) CONCRETE SLAB
- +r—.3 r
o
c�
CIDI
�
LU
Lu
J
zl1�
IL
TL#: 0721049210
IL IL I
±87,120 SQ. FT. (2.0
Ir
EL
U)
ACRES)
{
I
I
I
r
k
I
�� i
1F (E)ASPHALT
PARKING LOT
PROPERTY LINE N88" 31' 43" E (t309.W)
1 r
i
I
PLAN NORI
1
T • Mobile •®
19807 NORTHCREEK PKWY
BOTHELL. WA 98011 OFFICE (425) 398-7600
REALC0M
PLANS PREPARED BY:
`E CUWJ EF43T0NE
15928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 96072
PHONE: 42SA871732 FAX:425.487.1734
EMAIL: wI@wmamIon"ngrwm
W CORNERSTONE-ENGIR COM
WW
PROJECT INFO:
S E04693A
MIRROR LAKE / CINGULAR
/ KC FIRE
31617 1st AVENUE S
FEDERAL WAY, WA98003
KING COUNTY
ISSUED FOR:
CCONSTRUCTION
=REV:: DATE:=ISSUED FOR: BY:j
OQ 05-11-12 CONSTRUCTION KID
Qp 04-27-12 CLIENT REVIEW JRF
L-DRAWN BY:—CHK.: APW
JRF DRA MWO
[LICENSURE--
CURRENT ISSUE DATE:
08-16-12
LDRAWING INFORMATION:'
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE aMSULTANT9 OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OFTHIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
Is PROPRIETARY BY NATURE ANY USE OR DMCLMUIIx E
OTHER THAN WHICH L4 RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
SITE PLAN
DRAWING NUMBER:
A-1 0
CEI JOB NUMBER: 12-06007
NOTES:
1. CONTRACTOR TO PROVIDE ALL HANGERS & HARDWARE
(STAINLESS STEEL &/OR GALVANIZED ONLY) TO SUPPORT
CABLES & JUMPERS EVERY 3'-0".
2. RETURN USED LNNS & MCPA'S TO T-MOBILE WAREHOUSE.
3. PROPOSED 100AMP BREAKER IN VALARE POWER SHELF W/ (2) #2
THHN STRANDED IN EMT OR LT FLEX FROM BREAKER TO COVP.
4. CONTRACTOR TO REMOVE EXISTING RET HOME RUN COAX AND
UNUSED GPS ANTENNA WITH CABLE.
5. CONTRACTOR TO MAINTAIN CLEARANCE FOR EXISTING CLIMBING
PEGS WHEN INSTALLING RRH'S & NEW UNIVERSAL RING MOUNT.
I
W I
(E) 100 GAL PROPANE TANK
�
r
�
r
�
I
[CN J
W
I
(E) T MOBILE OPEN AIR
I
W
EQUIPMENT SHELTER
(E)PROPANE NERATOR
`II
W
W
I�
1
I
(E) GRAVEL
ACCESS WALKWAY
V�
(E) CONCRETE SLAB
I
W/ UTILITY BOX
I
EXISTING ENLARGED SITE PLAN
22x34 SCALE: 1/2" = T-0"
I 1 Tx17 SCALE: 114' = 1'-W
14,-0„ t7'-11„
(E) T-MOBILE LEASE AREA
ALL 1
1 (E) RR65-19-02DP (GAMMA SECTOR; 350"
AZIMUTH), TYP. TO BE REMOVED &REPLACED
F(E)
(E) TMATO REMAIN (2 PER SECTOR, TOTAL OF 6)
,(E) t150'-0" HIGH STEEL MONOPOLE
(E)LANDSCAPI NG (TYP)
VICE LIGHT
LITIES
ED TO WALL -am
Ol 1 , 0 Ile
f
(E) MCPA
CABINET
zm
(E) NOKIA
ULTRASITE
' CABINET ffi
(E) NOKIII
' ULTRASITE { `k, >: � � ;;', �ti , ^r•{ ,; }.� . , � ; {�\�C
CABINET _
I
(E) T-MOBILE ICE BRIDGE W/ (12) 7/8"0 COAX
(E) RR65-19-02DP (BETA SECTOR; 240'
AZIMUTH), TYP. TO BE REMOVED & REPLACED
0
(E) RR65-19-02DP (ALPHA SECTOR; 120'
AZIMUTH), TYP- TO BE REMOVED &
(E) OTHER (CARRIER EQUIPMENT SHELTER -
I / i
(E) 6'-0- HIGH CHAIN -LINK FENCE
W/ BARB WIRE (TYP)
(E) CHAIN -LINK FENCE
4
PLAN NORI
T • Mobile•®
19807 NORTH CREEK FKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
[ PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
C-1:Cpl"1►+lEirLL3TGNE
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE. WA 96072
PHONE: 425487.1732 FAX:425.4B71734
EMAIL: wi@mmGmtcn ngr.mm
W W W.CORNERSTONE-ENGR.COM
.,PROJECT INFO:
SE04693A
MIRROR LAKE / CINGULAR
/ KC FIRE
31617 1st AVENUE S
FEDERAL WAY, WA 98003
KING COUNTY
~ ISSUED FOR
CCONSTRUCTION
,REV:' FOR: BY:
Qp 05-11-12 CONSTRUCTION KID
Al04-27-12 CLIENT REVIEW JRF
DRAWN BY:=CHK.: APV.:
11 JRF I DRA 1 MW-071
CCURRENT ISSUE DATE:
08-16-12
=LICENSURE:
4 cF ry0;r
4h
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORSANOOMISSIONS ALLPREVIOUS ESSUESOF THIS
DRAWING ARE SUPERSE DED BY THE LATEST REVISI ON.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
EXISTING ENLARGED
SITE PLAN
—nRAW[NC, NUMBER:. -
A-1.1
0
CEI JOB NUMBER: 12-06007
\V \V w
NOTES:
1. CONTRACTOR TO PROVIDE ALL HANGERS & HARDWARE
(STAINLESS STEEL WOR GALVANIZED ONLY) TO SUPPORT
CABLES & JUMPERS EVERY 3'-0".
2. RETURN USED LNA'S & MCPA'S TO T-MOBILE WAREHOUSE.
3. PROPOSED 100AMP BREAKER IN VALARE POWER SHELF W/ (2) #2
THHN STRANDED IN EMT OR LT FLEX FROM BREAKER TO COVP.
4. CONTRACTOR TO REMOVE EXISTING RET HOME RUN COAX AND
UNUSED GPS ANTENNA WITH CABLE.
5. CONTRACTOR TO MAINTAIN CLEARANCE FOR EXISTING CLIMBING
PEGS WHEN INSTALLING RRH'S & NEW UNIVERSAL RING MOUNT.
I
I
I
_
`I,
f
I
(E) 100 GAL PROPANC
TANK
(
PROPOSED (1)
HIGH CAPACITY
W
COVP'S MOUNTED TO BACK OF ..>-
CABINET.
j1
(E) NOKIA ULTRASITE
A3�'
\ �I
v J
i�•1 J
W
FL
I
MOBILE
(E) T OPEN NR
EQUIPMENT SHELTER
W
I
W
(E) PROPANE GENERATOR
iliz
I
I
GRAVEL
A
ACCESS WALKWAY I '
�V
(E) CONCRETE SLAB
(
W/ UTILITY BOX
I
I /
�I
I
`I
PROPOSED ENLARGED SITE PLAN
22x34 SCALE: 1/2" = V-0' I 11x17 SCALE: 1/4" = T-T
14,-0„ tT-11"
(E) T-MOBILE LEASE AREA 3
t I
I
0
I
F(E)CE LIGHTES TO WALL
W
PROPOSED NEW PANEL
ANTENNA TMBXX-6516-R2M F -
(GAMMA SECTOR; 350° AZIMUTH) (- 6 1
V/ PROPOSED REPLACEMENT ANTENNA
TMBXX-6516-R2M TO REPLACE (E) ANTENNA
(GAMMA SECTOR; 350' AZIMUTH), TYP +' S
(E) TM`AIT/O REMAIN (2 PER SECTOR, TOTAL OF \6)
W � W
(E) t150'-0" HIGH STEEL MONOPOLE
(E)LANDSCAPING (TYP)
\�/ I
\�/I
2as�
(E) MCPA
CABINET r
I pROPO$f=D UNIVERSAL RING Q
MOUNT W/ STANDOFF ARM A-3.1
r�
(E) NOKIA
ULTRASITE PROPOSED (1) FRIG MOUNTED
1 ' CABINET TO (E) NEW ANTENNA PIPE 11
MAST @ EACH SECTOR A-3
A.�c; .,�:r:;,.:.:: •: _ '�; h• \''�'�� tit �f� .��
(E) NOKIA v j Cf (: ''. `� j PROPOSED NEW PANEL
ULTRASITE vrti\/ ,;' ANTENNA TMBXX-6516-R2M 6
' CABINET ^ n { (ALPHA SECTOR; 120° AZIMUTH)
PROPOSED REPLACEMENT ANTENNA
(E) T-MOBILE ICE BRIDGE WI(12) 7/6"OI COAX I -
(E) & PROPOSED (1) HIGH CAPACITY HYBRID (ALPHA SECTOR;
TO REPLACE ), ANTENNA
CABLE ROUTED TO MATCH (E) COAX 9 {ALPHA SECTOR; 120° AZIMUTH), TYP �1
A-3 -RF-i=
I I I
PROPOSED (1) HIGH CAPACITY
COVP'S MOUNTED TO PROPOSED 1
UNIVERSAL RING MOUNT A-3 (E) OTHER CARRIER EQUIPMENT SHELTER
PROPOSED NEW PANEL ANTENNA
TMBXX-6516-R2M (BETA SECTOR; 240° AZIMUTH] R�1
(E) 6'-0" HIGH CHAIN -LINK FENCE
W/ BARB WIRE (TYP)
PROPOSED (2) FXFB'S (REMOTE RADIO UNITS), 7
MOUNTED TO PROPOSED UNIVERSAL RING MOUNT A3
(E) CHAIN -LINK FENCE
j PROPOSED REPLACEMENT ANTENNA
TMBXX-6516-R2M TO REPLACE (E) ANTENNA 6
(BETA SECTOR; 240° AZIMUTH), TYP RF-1
�V PLAN NORTF
1
T • Mobile-'
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 9BO72
PHONE: 425487.1732 FAX: 425.487.1734
EMAIL: mQmmemton ngr.mm
W W W.CORNERSTONE-ENGR.COM
PROJECTINFO
L-ISSUED FOR
CCONSTRUCTION
=REV:-DATE:=ISSUED FOR: BY:�
OQ 05-11-12 CONSTRUCTION KIO
Qp 04-27-12 CLIENT REVIEW JRF
'--DRAWN BY:=CHK.: APV.:
JRF DRA MWO
I -CURRENT ISSUE DATE:
08-16-12
LICENSURE:
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALLDIMENSIONS AND ADVISE CONSULTANTS OFANY
ERRORS AND OMGSiONS. ALL PREVIOUS ISSUES OF THIS
ORAWING ARE SUPERSE DED BY THE LAYEST REV15EON.
THE WFORMATION CONTAINED IN 7H15 SET OF DOCUMEIMS
IS PROPRIETARYBY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELAYED TO NAMED CLIEWNS
STRICTLY PROHIBITED -
DRAWING TITLE:
PROPOSED ENLARGED
SITE PLAN
DRAWING NUMBER:
A-1.2 0
CEI JOB NUMBER: 12-06007
■ �T.O.;EI MONOPOLE
■ EL ±150'-0" AGL
(E) OTHER CARRIER ANTENNA ARRAY
PROPOSED (1) HIGH CAPACITY COVP MOUNTED 4
TO PROPOSED UNIVERSAL RING MOUNT
(E) TMA TO REMAIN (2 PER SECTOR, TOTAL OF 6)
RA�D CENTER OF PROPOSED PANEL ANTENNAS
Y EL 116'0" AGL -
PROPOSED ANTENNA PIPE MAST TO MATCH (E)
CUT LENGTH TO SUIT (1 PER SECTOR, TOTAL OF 3)
1 ,
PROPOSED UNIVERSAL RING MOUNT W1 STANDOFF ARM A 3.1
(E) T-MOBILE ICE BRIDGE W1(12) 718"0 COAX &
PROPOSED (1) HIGH CAPACITY HYBRID CABLE
ROUTED UP (E) MONOPOLE TO MATCH (E) COAX
(E) T-MOBILE SITE SUPPORT
CABINETS, BEYOND -
(E) T-MOBILE OPEN-AIR
EQUIPMENT SHELTER -
GRADE
SOUTH ELEVATION
F-,,INT NOTE:
ALL PROPOSED ANTENNASfEGUIPMENT &
ATTACHMENTS SHALL BE PAINTED TO
MATCH EXISTING ON -SITE CONDITIONS.
(E) OTHER CARRIER MW DISH
PROPOSED (2) FXFB'S
(REMOTE RADIO UNITS),
MOUNTED TO PROPOSED T
UNIVERSAL RING MOUNT A3 .I
PROPOSED (1) FRIG
MOUNTED @ ANTENNA
PIPE MAST (1 PER 11
SECTOR, TOTAL OF 3) A�
PROPOSED REPLACEMENT
& NEW PANEL ANTENNA
TMBXX-6516-R2M 6
(3 PER SECTOR, TOTAL OF 9) R
�.
(E) OTHER CARRIER ANTENNA ARRAY
(E)±150'-0" HIGH STEEL MONOPOLE
(E) OTHER CARRIER ANTENNA ARRAY
PROPOSED (2) FXFB UNIT
MOUNTED TO PIPE MAST
NOTE:
CONTRACTOR TO MAINTAIN
CLEARANCE FOR EXISTING CLIMBING
PEGS WHEN INSTALLING RRH'S &
NEW UNIVERSAL RING MOUNT
PROPOSED (1) HIGH
CAPACITY COVP
MOUNTED TO PIPE MASI
ENLARGED DETAIL
22x34 SCALE: 1f2" = 1'-0`
(E) 6'-0" HIGH CHAIN -LINK FENCE Wl BARB WIRE
(E) OTHER CARRIER EQUIPMENT SHELTER
11x17 SCALE: 114" = 1'-0"
PROPOSED UNIVERSAL RING MOUNT �
WI STANDOFF ARM MOUNTED ! ' l
DIRECTLY ABOVE (E) ANTENNA MOUNT A3.1
T • Mobile•®
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-760D
=PROJECT CONSULTANTS:
REALC0M
=PLANS PREPARED BY:
Ce Ca;7NE'?l3TONE
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA98072
PHONE: 425.487.1732 FAX:425.487.1734
EMAIL: mQwmemlor n9r.wm
WWW CORNERSTONE-ENGR.COM
'.PROJECT INFO:
L ISSUED FOR'
CI CONSTRUCTION71
"REV.=DATE:�ISSUED FOR: BY:=
Qp 05-11-12 CONSTRUCTION KIO
QA 04-27-12 CLIENT REVIEW JRF
=DRAWN BY:=CHK.: APV.;
JRF DRA MWO
CURRENT ISSUE DATE:
08-16-12 771
—1 IC`�NC11RF-
,SL
." r°fn
�►�'+onwt �[iOL� 1�
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
=DRAWING TITLE:
SOUTH ELEVATION
=DRAWING NUMBER:
A-2 0
CEI JOB NUMBER: 12-06007
22x34 SCALE: 118" = V-W 111x17 SCALE' 1116" = V-0"
PAINT NOTE:
T.O. IE) MONOPOLE ALL PROPOSED ANTENNAS/EQUIPMENT
& ATTACHMENTS SHALL BE PAINTED TO
AV EL t150'-0" AGL MATCH EXISTING ON -SITE CONDITIONS.
(E) OTHER CARRIER MW DISH
(E) OTHER ER
AN EN A ARRAY
PROPOSED (1) HIGH
CAPACITY COVP
(1) FRIG MOUNTED TO PROPOSED
PROPOSED 7
MOUNTED (ANTENNA UNIVERSAL RING MOUNT p.
PIPE MAST (1 PER 1 (E) TMA TO REMAIN (2 PER
SECTOR, TOTAL OF 3) A-3 ` r SECTOR, TOTAL OF 6)
RAD CENTER OF PROPOSEDPANEL
EL I18'-0" AGLNAS 41
1 I�
PROPOSED ANTENNA PIPE MAST ,
TO MATCH (E) CUT LENGTH TO
SUIT (1 PER SECTOR, TOTAL OF 3) PROPOSED
REPLACEMENT & NEW
PROPOSED UNIVERSAL RING PANEL ANTENNA
TMBXX 6516-R2M
MOUNT W/ STANDOFF ARM 1
A (3 PER SECTOR,
TOTAL OF 9) , 6
RP-1
(E) OTHER CARRIER
ANTENNA ARRAY
(E) t150'-0" HIGH STEEL
MONOPOLE
(E) OTHER CARRIER
ANTENNA ARRAY
(E) T-MOBILE ICE BRIDGE W/ (12) 7/8"0
COAX & PROPOSED (1) HIGH
CAPACITY HYBRID CABLE ROUTED UP
(E) MONOPOLE TO MATCH (E) COAX
(E) 6-0" HIGH CHAIN -LINK ' I I ` (E) T-MOBILE OPEN-AIR
FENCE W/ BARB WIRE I EQUIPMENT SHELTER
(E) OTHER CARRIER +
EQUIPMENT SHELTER 1r (E) T-MOBILE SITE
SUPPORT CABINETS,
GRADE (REF) + BEYOND
T.O. (E) MONOPOLE
Aw EL t150'-O" AGL
(E) OTHER CARRIER MW DISH —
(E) OTHER CARRIER
ANTENNA ARRAY
PROPOSED (2) FXFB'S
(REMOTE RADIO UNITS),
MOUNTED TO PROPOSED
UNIVERSAL RING MOUNT
(E) TMA TO REMAIN (2 PER
SECTOR, TOTAL OF 6) .-
RAD CENTER OF PROPOSED
jk PANEL ANTENNAS
EL 118'-0" AGL
PROPOSED ANTENNA PIPE MAST
TO MATCH (E) CUT LENGTH TO
SUIT (1 PER SECTOR, TOTAL OF 3)
PROPOSED UNIVERSAL RING
MOUNT W/ STANDOFF ARM
(E) OTHER CARRIER
EQUIPMENT SHELTER
GRADE
PAINT NOTE:
ALL PROPOSED ANTENNAS/EQUIPMENT
& ATTACHMENTS SHALL BE PAINTED TO
MATCH EXISTING ON -SITE CONDITIONS.
PROPOSED (1) FRIG
MOUNTED @ ANTENNA
PIPE MAST (1 PER 11
SECTOR, TOTAL OF 3) A�
PROPOSED
REPLACEMENT & NEW
PANEL ANTENNA
TMBXX-6516-R2M
(3 PER SECTOR,
TOTAL OF 9) Li
RF-1
(E) OTHER CARRIER
ANTENNA ARRAY
(E) t150'-0" HIGH STEEL
MONOPOLE
(E) OTHER CARRIER
ANTENNA ARRAY
NORTH ELEVATION 1 3 EAST ELEVATION 2
22x34 SCALE: 1 /8" = 1'-0" 111 xi SCALE: 1116" = V-0" I 2x34 SCALE: 1 /8" = V-0" I Ixl7 SCALE: 1 /16" = T-W
I—
PAINT NOTE:
T.O. [E] MONOPOLE ALL PROPOSED ANTENNAS/EQUIPMENT
51, & ATTACHMENTS SHALL BE PAINED TO
EL t150'-0" AGL MATCH EXISTING ON -SITE CONDITIONS.
(E) OTHER CARRIER MW DISH
(E) OTHER CARRIER
ANTENNA ARRAY — —_ d Il it
PROPOSED (1) HIGH CAPACITY
COVP MOUNTED TO PROPOSED
UNIVERSAL RING MOUNT
PROPOSED (1) FRIG
MOUNTED @ ANTENNA
PIPE MAST (1 PER R 1
SECTOR, TOTAL OF 3) a
RAD CENTER OF PROPOSED
PANEL ANTENNAS _
EL 118'-0" AGL
PROPOSED ANTENNA PIPE MAST
TO MATCH (E) CUT LENGTH TO
SUIT (1 PER SECTOR, TOTAL OF 3)
PROPOSED UNIVERSAL RING
MOUNT W/ STANDOFF ARM
(E) T-M OBI LE OPEN-AIR
EQUIPMENT SHELTER -
GRADE
WEST ELEVATION
22x34 SCALE: 118" = V-0" i 1 x17
PROPOSED (2) FXFB'S
(REMOTE RADIO UNITS),
MOUNTED TO PROPOSED
UNIVERSAL RING MOUNT( 7 •1
Aa)
(E) TMA TO REMAIN (2 PER
SECTOR, TOTAL OF 6)
PROPOSED
REPLACEMENT & NEW
PANEL ANTENNA
TMBXX-6516-R2M
(3 PER SECTOR,
TOTAL OF 9) . 6
RF-1
` (E) OTHER CARRIER
ANTENNA ARRAY
(E) t150'-0" HIGH STEEL
MONOPOLE
(E) OTHER CARRIER
ANTENNA ARRAY
(E) T-MOBILE SITE
SUPPORT CABINETS,
BEYOND
1
T • Mobile " QD
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
~PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
�E CdFiNEFR 6T0NE
16928 WOODINVILLE-REDMOND RD NE, SURE 210
WOODINVILLE, WA 98072
PHONE: 425487.1732 FAX:425487.1734
EMAIL; ceI@wmemlceeangrwm
W W W.CORNERSTONE-ENGR.COM
—PROJECT INFO:
ISSUED FOR:
CCONSTRUCTION
r"REV.=DATE:—ISSUED FOR: BY:�
DRAWN BY:=CHK.: APV.:
JRF I DRA MWO
CURRENT ISSUE DATE:
11 08-16-12
qmo,( v
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL D IMENSION S AND ADVISE OONSUILTANYS 0 F ANY
ERRORS AND OMI SSIONS. ALL PREYIOIFS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY 8Y NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH 15 RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
NORTH, EAST & WEST
ELEVATIONS
DRAWING NUMBER:
A-2.1 0
CEI JOB NUMBER: 12-06007
6" =1,4r
opm,w
TOP
O O 00
FRONT
NOKIA FRIG RRH
22x34 SCALE: 3"=1'-0'
Ilixil SCALE: 1 1/2" = 111 W
RxO 4
ANT 4 RX
ANT 5 TX/RX _
RxO 5 RxO 3
ANT 6RX
ANT
TYJRX
PWR IN
RxO 6
LED FAN/TX
OFF STATUS
LED MODULE
STATUS —
GROUNDING POINTS
OPT 1--/
OPT 2-
EAC OPT 3
1'-5 518"
NOKIA FXFB RRH MODEL #472166A
22x34 SCALE: 3" = 1'-0" 111x17 SCALE: 1 112" = V-0"
i o 0 0 0
fsw++ewrww +rrrr
r�.
FRIE RRU
(TOWER MOUNTED)
J
RIGHT SIDE
ANT 2 RX
RxO 2
RxO 1
ANT 1 TX/RX
RET
(FXFB ONLY)
i
NOTE:
FOR MOUNTING SEE
DETAIL 2/A-3.1
11
PROPERTY
VALUE
HEIGHT
133 mm/3U (5.2 in)
WIDTH WIDTH
447 mm 17.6 in)
(WITH COVERS)
490 mm (19.3 in)
DEPTH (FOR RACK
395 mm (15.6 in)
ASSEMBLIES) DEPTH
560 mm (22 in)
(WITH COVERS)
WEIGHT (INCLUDING
THE CORE, FANS
MAX. 25 kg (55.1 lb)
AND CASING)
NOTE:
FOR MOUNTING SEE
DETAIL 2/A-3.1
_ 3 11116"
I
GROUNDING
HARDWARE
TOP 7-16 DIN MALE
7-16 DIN MALE
GROUNDING
HARDWARE
WEATHERPROOF
ASIG INPUT
CONNECTOR —
7-16 DIN FEMALE
--r (18) FIBER INDOORIOUTDOOR
DISTRIBUTION CABLE
DIELECTRIC CENTRAL
MEMBER
(2) #18 AWG COPPER PAIR
(10) #6 AWG THHNrrHWN
COPPER CONDUCTOR
(2) ARAM ID RIPCORDS
CORRUGATED LAMINATED
STEEL TAPE
MDPE OUTER JACKET
FRONT SIDE
BIAS TEE 1 o HIGH CAPACITY HYBRID CABLE
22x34 SCALE: 6" = V-0" 11x17 SCALE: 3" = T-0" 22x34 SCALE: NTS 111x17 SCALE: NTS
COVP MOUNTING FRAME ,
f- ALARM
OVP CONNECTION
rf 1/4"0 GALV BOLT
% (TYP OF 8 PER COVP
FIBER PANEL MOUNTING BRACKET)
MAIN GROUND f 18 2I0-14AWG SM ADAPTERS PIPE
® ®�"
c T U-BOLT
RETURN 15
CONNECTIONS
2/0 - 14 AWG
GROUNDBAR
4-14AWG —
48-15 CONNECTIONS
2/0 - 14 AWG
7 HIGH CAPACITY COVP INTERIOR
22x34 SCALE: 1 1/2" = 1'-0" I 11x17 SCALE: 3/4" = T-O"
PROPERTY
3-SECTOR RF MODULE
DUAL RF MODULE
SINGLE RF MODULE
HEIGHT
133 mm/3U (5.2 in)
133 mm/3U (5.2 in)
133 mm/3U (5.2 in)
WIDTH
447 mm (17.6 in)
447 mm (17.6 in)
447 mm (17.6 in)
WIDTH (WITH COVERS)
490 mm (19.3 in)
490 mm (19.3 in)
490 mm (19.3 in)
DEPTH (FOR RACK
mm
395 mm in)
395 mm 15.6 in
( )
ASSEMBLIES) DEPTH
(22 i)
560 mm (22 in)
56
(22 i
560 mm (22 in)
560 mm (22 in)
(WITH COVERS)
WEIGHT (INCLUDING THE
25 kg (55.1 lb)
21.8 kg (48.1 lb)
18.7 kg (41.2lb)
CORE, FANS AND CASING)
^r
RIGHT SIDE ED
M
LN
NOTE:
FOR MOUNTING SEE
DETAIL 2/A-3.1
NOKIA FRIA RRH 3
22x34 SCALE: 1 V2" = 11-0" 11X17 SCALE: 3/4"= T-0"
1'-5 13/16"
1'-4 1 /B"
FRONT
HIGH CAPACITY RAYCAP COVP
22x34 SCALE: 1 1!2" = T-0" I 1 Ix17 SCALE: 314- = 1'-0"
L 1/4"0 GALV BOLT
(TYP OF 4 PER COVP)
COVP
RIGHT SIDE TOP
6 COVP MOUNT
2204 SCALE: 1 1/2" = 1'-0"
7"
5 13/16"
RIGHT SIDE
T • •Mobile•®
19807 NORTH CREEK PKWY
BOTHELL. WA 98011 OFFICE (425) 398-7600
PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
� r G+Sr'TlJ Fr ! TONE
16926 WOODINVILLE-REDMOND RD NE, SUnE 210
W OODINVILLE, WA 98072
PHONE: 4254071732 FAX:425.487.1734
EMAIL: mi@wmemlone-ergrwm
W W W CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR:
CCONSTRUCTION
,REV:'DATE:=ISSUED FOR: BY:::�
Q05-11-12
CONSTRUCTION
KID
QA
04-27-12
CLIENT REVIEW
JRF
DRAWN BY:=CHK.: APV.:
JRF DRA MWO
CURRENT ISSUE DATE:
5 L..�r..�..� . 08-16-12
NOTE:
FOR MOUNTING SEE
DETAIL 5/A-3
HYBRID TRUNK IN
POWER & FIBER
JUMPER OUT (TYP)
7/8"
BOTTOM
urc�9vlrvu IrvrVRIVH11V1V.
DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBRED.
DRAWING TITLE:
F- DETAIL SHEET
DRAWING NUMBER:
A-3 0
1 CEI JOB NUMBER: 12-06007
�t
PARTS LIST
ITEM #
QUANTITY
PART NUMBER
DESCRIPTION
1
2
601257
ANGLE ARM
2
2
601256
MOUNTING CLAMP
3
2
601235-1
BRACKET
4
2
601235-2
BRACKET
5
1
601258
LABEL, ANGLE
6
4
600679-3
SPACER TUBE
7
14
100525-24
ME FLAT WASHER (STAINLESS STEEL)
8
2
600419-8
M8x1.25x25mm LARGE CARRIAGE BOLT (STAINLESS STEEL)
9
6
6/1/7395
M8 LOCK WASHER (STAINLESS STEEL)
10
4
600419-10
M8x1.25x110mm LARGE HEX HEAD SCREW (STAINLESS STEEL)
11
6
204001-15
M8x1.25 HEX NUT (STAINLESS STEEL)
12
2
225244
CLAMP PLATE
13
8
600419-24
LARGE LOCK WASHER (STAINLESS STEEL)
14
8
204001-21
M12x1.75 HEX NUT (STAINLESS STEEL)
15
4
600419-12
M12x1.75x150mm LARGE CARRIAGE BOLT (STAINLESS STEEL)
17
1
601584
MOLYBDENUM DISULFIDE GREASE
BOTTOM BRACKET
1 a 7
TOP BRACKET
ANTENNA BRACKET ATTACHMENT
22x34 SCALE: NTS 111 xi SCALE: NTS
FRONT
RIGHT SIDE
MOUNTING PLINTH (FMF
22x34 SCALE: 1 112" = V-0" 111x17 SCA
U-BOLT MOUNT LOCATION
(TYP OF 2)
FPKAIJ-BOLT MOUNT
LOCATION (TYP OF 2)
FLOOR MOUNT LOCATION
(TYP OF 6)
- FPKA MOUNTING
BRACKET
NOT USED
22x34 SCALE: NTS
c
3" STD WT PIPE
I11x17 SCALE: NTS
ANTENNA
7 ANTENNA ATTACHMENT
22x34 SCALE: NTS Tilx17 SCALE: NTS
3" STD WT PIPE
3
FPKA MOUNTING BRACKET "
4
FMFA MOUNTING PLINTH
RF MODULE
M8x120 BOLT
M10x120x105mm BOLT
FMFA FIXING POINTS
MOUNTING BRACKET (FPKA
= V-0" I 22x34 SCALE: NTS I 11x17 SCALE: NTS
I
3 RRH MOUNTING
22x34 SCALE: NTS 11x17 SCALE:
RF MODULE
10 1 NOT USED
22x34 SCALE: NTS
6 1NOT USED
22x34 SCALE: NTS
11x17 SCALE: NTS
11x17 SCALE:
0
kl
II
III
II
QUAD UNIVERSAL RING
MOUNT (VALMONT #852361)
8" STANDOFF ARM FOR
SINGLE ANTENNA
(VALMONT gMM01) � .F.
3"STDWTxM'PIPE I
21 UNIVERSAL RING MOUNT
22x34 SCALE: NTS I 11x17SCALE: NTS
0
5
1
T Mobile -
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
Ce)-Ff
NEERSIrONE
N—RING. INC
16928 WOODINVILLE-REDMOND RD NE, SURE 210
WOODINVILLE, WA 98072
PHONE: 425A87.1732 FAx:425.4871734
EMAIL: ml@wmemlaa 119.mm
W W W CORNERSTONE-ENGR COM
, PROJECT INFO:
ISSUED FOR:
CLCONSTRUCTION
rREV.:DATE:=ISSUED FOR: BY:=—
Q05-11-12 CONSTRUCTION KID
A 04-27-12 CLIENT REVIEW JRF
:DRAWN BY:=CHK.: APW
JRF DRA MWO
=CURRENT ISSUE DATE:
08-16-12
= LICENSURE:
w
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFoRu&TION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
DRAWING TITLE:
DETAIL SHEET
=DRAWING NUMBER:
A-3.1 0
CEI JOB NUMBER: 12-06007
(2) 3/8"0 SS HEXNUT
RRH CHASSIS (#2) TWO HOLE
COMPRESSION LUG
GROUND WIRE STUD (TYP
NO -LUX ANTI -OXIDIZING OF 2 @ FRONT AND BACK
COMPOUND OF CABINET)
CLEAR HEAT SHRINK ON
COMPRESSION LUGS
3/8"0 STAR WASHER - #2 STRANDED GREEN
INSULATED COPPER GROUND
LEAD TO BUSS BAR OR #2
SOLID BARE TINNED COPPER
PLAN TO GROUND RING
NOTE:
FOR GROUNDING CONNECTIONS TO PAINTED CABINETS
CHASSIS, GRIND OFF ALL ENAMEL COATINGS TO BARE METAL
AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG
CONNECTION. APPLY NO -LUX TO ALL EXPOSED BARE METAL.
#2 GREEN INSULATED COPPER
WIRE TO AGB AT TOP OF POLE
COAX CABLE GROUNDING
KITS WITH LONG BARREL
COMPRESSION LUGS,
INSTALLED BY CONTRACTOR
HARGER GROUNDING BAR
#GB14824 (OR EQUAL) WITH
HOLE PATTERN, STANDOFF
INSULATORS AND MOUNTING
BRACKETS AS SHOWN
#2 SOLID BARE TINNED
COPPER WIRE TO GROUND
RING - PROVIDE (2) PER MGB
® = CADWELD
GROUND ATTACHMENT 112 TYPICAL MASTER GROUND BAR
22x34 SCALE: NTS 111x17 SCALE: NTS I 22x34 SCALE: NTS 11x17 SCALE: NTS
NOTE:
GROUND HYBRID CABLE TOP &
BOTTOM USING UNIVERSAL 1 5/8"
GROUNDING STRAP, PART#252172
SCHEMATIC GROUNDING PLAN
HARGER GROUNDING BAR
#GBI14412G
COAX CABLE, COVP &
RRU GROUNDING KITS
#2 GREEN INSULATED
COPPER WIRE TO MGB
AT BOTTOM OF POLE -
11 ACCESSORY GROUND BUSS BAR
22x34 SCALE: NTS 111x17 SCALE: NTS
(E) GROUND ACCESSORY BUSS BAR, TYP.
f 2 ] (E) ANTENNA MOUNT STRUCTURE.
PROPOSED #2 STRANDED GREEN INSULATED COPPER
GROUND LEAD, TYP.
(E) #2 STRANDED GREEN INSULATED COPPER GROUND
LEAD, TYP. (V.I.F.)
C 5 } PROPOSED GROUND CONNECTION TO RRH. SEE DETAIL 12
KEYED NOTES
22x34 SCALE: NTS 111x17 SCALE: NTS
SYMBOL I DESCRIPTION
MASTER GROUND BAR 1/4"x4"x24" COPPER
ACCESSORY GROUND BAR 1/4"x4"x12" OR
S 1/4"x4"x20" COPPER
ttTYPE GIR
NOTE:
CADWELD "TYPES" SHOWN ABOVE ARE EXAMPLES - CONSULT
WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS
TO BE USED FOR THIS PROJECT-
10 CADWELD CONNECTIONS 9
22x34 SCALE: NTS 111x17 SCALE: NTS
1. GROUNDING SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL
ELECTRICAL CODE.
2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS 8".
3. NO SPLICES PERMITTED IN GROUND CONDUCTORS.
4, ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT
THEIR MATING SURFACES AND INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS. USE PENETROX OR EQUIVALENT ANTIOXIDANT
GREASE.
5. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG COMPRESSION
TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK
CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR WILL BE
PERMITTED.
6. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE
MANUFACTURER'S SPECIFIED VALUES.
7. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY AT LEAST 6".
8. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT
EXCEED A RESISTANCE OF 5 OHMS TO EARTH.
9. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY
METAL OBJECTS OR SUPPORTS; TO PRECLUDE ESTABLISHING A "CHOKE"
POINT.
10. GROUND BARS SHALL NOT BE FIELD MODIFIED.
6 11. GROUND RING BURIAL DEPTH SHALL BE 30",
O
GROUND INSPECTION WELL
®
5/8"xV-0" COPPER CLAD STEEL GROUND ROD
®
COMPRESSION LUG/MECHANICAL CONNECTION
®
CADWELD CONNECTION
®
SIDE SPLICE CADWELD
FIELD VERIFY & TIE INTO EXISTING GROUNDING
PLAN NORTH
12. A CERTIFIED CONTRACTOR WILL MAKE ALL MEASUREMENTS REQUIRED
TO TEST THE GROUNDING SYSTEM USING A MEGGER OR EQUIVALENT.
THE ACCEPTABLE RESISTANCE MEASURED FOR THE GROUNDING
SYSTEM WILL NOT EXCEED 5 OHMS RESISTANCE. THREE DISTANCES
SHALL BE USED: 1 AT 100 FEET, 1 AT 70 FEET, AND 1 AT 35 FEET. THESE
DISTANCES ARE SUBJECT TO A SITE BY SITE BASIS. T-MOBILE-WTS SHALL
BE GIVEN 24 HOURS NOTICE. ALL COSTS ASSOCIATED WITH GROUND
TESTING WILL BE AT THE EXPENSE OF THE CONTRACTOR.
3 1 LEGEND 1 2 GROUNDING NOTES 1 1
22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS
T Mobile•®
19807 NORTH CREEK PKWY
BOTHELL, WA 98011 OFFICE (425) 399-7600
`PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
EE C:0391VEIr19TONE
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE. WA 98072
PHONE: 425AB71732 FAX:425.4871734
EMAIL:-i@wmelsla "n9rm
W W W.CORNERSTONE-ENGR COM
r-PROJECT INFO:
SE04693A
MIRROR LAKE / CINGULAR
/ KC FIRE
31617 1st AVENUE S
FEDERAL WAY, WA98003
KING COUNTY
ISSUED FOR:
CCONSTRUCTION
r REV:- DATE: =ISSUED FOR: BY:=
DRAWN BY:=CHK.: APV.:'
JRF ORA MWO
[[I CURRENT ISSUE DATE:
08-16-12
If_r7m" "',
o ISO (lt-
=DRAWING INFORMATION:
DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE, ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
=DRAWING TITLE:
SCHEMATIC GROUNDING PLAN
8 DETAILS
=DRAWING NUMBER:
E-1 0
CEI JOB NUMBER: 12-06007
22x34 SCALE: 3/4" = V-0" 111x17 SCALE: 3/8" = 1'-0"
RF
DATA SHEET
SECTOR
COLOR
# OF
ANTENNAS
ANTENNA
VENDOR
ANTENNA MODEL
AZIMUTH
(TN)
MECHANICAL
DOWNTILT
ELECTRICAL
DOWNTILT
RAD CENTER
HYBRID CABLE
LENGTH
COAX CABLE
LENGTH
ALPHA (S-1)
RED
3
ANDREW
TMBXX-6516-R2M
120°
TBD
TBD
118'-0" AGL
130'
N/A
BETA (S-2)
GREEN
3
ANDREW
TMBXX-6516-R2M
240°
TBD
TBD
118'-0" AGL
GAMMA (S-3)
YELLOW
3
ANDREW
TMBXX-6516•R2M
350°
TBD
TBD
116'-0" AGL
UL & DL FREQUENCIES:
SEATTLE MARKET:
PCs:
UL: 1885 - 1895 Mhz, 1900 -1905 Mhz
DL: 1965 - 1975 Mhz, 1980 -1985 Mhz
AWS:
UL: 1745 - 1755 Mhz, 1730 -1735 Mhz
DL: 2145 - 2155 Mhz, 2130 - 2135 Mhz
RF DATA SHEET
22x34 SCALE: NTS lllxl7
COAXIAL CABLE NOTES:
1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED.
2. CONTRACTOR TO PROVIDE DRIP LOOPS IN CABLES AND JUMPERS WHERE
NECESSARY.
3. TAGGING:
3.1 ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE
TO INDICATE THE ANTENNA SECTOR.
3.2 COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE
AND EACH END OF JUMPERS AS CLOSE TO EACH END AS
POSSIBLE. (NOT TO INTERFERE WITH WEATHERPROOFING).
4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0"
ON CENTER. CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO
MEET THIS REQUIREMENT.
11
1 f.I
,- CONNECTORS J+
STEP 1
2" 2"
I�
ELECTRICAL TAPE BUTYL TAPEF(ALSOOWN(1 LAYER) AS MASTIC, PE)
STEP 2
4"
ELECTRICAL TAPE: 3 LAYERS WITH 2" TAPE AND 3
LAYERS IN 3/4" TAPE (ALL WITH MINIMUM 50%
OVERLAP). ALL TAPE ENDS SHALL BE CUT (DO NOT
COAT WITH 3M SCOTCH COTE SPRAY SEALER. —
STEP 3
NOTE:
4" VERTICAL CONNECTIONS SHALL BE
I TAPED FROM THE BOTTOM UP SO
OVERLAP MOVES WATER AWAY FROM
CONNECTION, TYP.
PROVIDE HEAT SHRINK IN PLACE OF
I —I TAPE FOR QUAD POLES AND LNA's (TYP.)
STEP 4
COAXIAL CABLE WEATHERPROOFING
22x34 SCALE: NTS 111x17 SCALE: NTS
3
11 15/16"
FRONT
a TOP
SEA fOR 1, 2 & 3
(9) TMBXX-6516-R2M QUAD ANTENNAS
(5) MODULES (2 FXFB + 3 FRIG)
(1) HYBRID CABLE & (2) COVP
KEEP ALL EXISTING TMA'S
KEEP ALL COAX
SIDE ISOMETRIC PROJECT SUMMARY
22x34 SCALE: NTS lllxl7
ANDREW TMBXX-6516-R2M ANTENNA
MECHANICAL SPECIFICATIONS
PART NUMBER
I HEIGHT
WIDTH
IDEPTH WEIGHT
TMBXX-6516-R2M
591n (wish anuator) 111.9in
163in 134.6Ibs
CONNECTORS STANDARD MOUNTING HARDWARE
2) 7-16 DIN INCLUDED
ELECTRICAL SPECIFICATIONS
FREQUENCY
I POLARIZATION
GAIN
AZIMUTH B.W.
ELEVATION B.W.
1710-2155 MHz
±45°
17.5° t 0.8
64.5° t 8
7.2° t 1.2
VSWR
I MAX INPUT POWER
1.35:1 / 16.5
1250 WATTS
1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY
T-MOBILE AND INSTALLED BY CONTRACTOR.
2. COAX COLOR CODING: ANTENNAS TO BE NUMBERED IN A CLOCKWISE
MANNER FROM TRUE NORTH AND COLOR CODED TO ESTABLISHED
T-MOBILE STANDARDS.
T - -Mobile
19807 NORTH CREEK PXWY
BOTHELL, WA 98011 OFFICE (425) 398-7600
PROJECT CONSULTANTS:
REALC0M
PLANS PREPARED BY:
�E COi�W6PLETONE
16928 WOODINVILLEaREDMOND RD NE. SURE 210
WOODINVILLE, WA 98072
PHONE: 425AB7.1732 FAX:425487.1734
EMAIL: wi@--mtom -91mm
W W W CORNERSTONE-ENGR COM
PROJECT INFO:
9 SE04693A
MIRROR LAKE / CINGULAR
/ KC FIRE
31617 1 st AVENUE S
FEDERAL WAY, WA98003
KING COUNTY
3. COAX COLOR CODING APPLIES TO SECTORIZED SITES. FOR OMNI SITES,
USE THE ATO, BTO & GTO COLOR CODES ONLY.
4. COAX SHALL BE TAGGED WITH COLOR CODING AT (2) PLACES USING 1"
WIDE WEATHER PROOF COLORED VINYL TAPE AT THE FOLLOWING
LOCATIONS:
#1 - AT ANTENNA CONNECTION
#2 -AT ENTRY TO EQUIPMENT CABINET
5. RUN COAXIAL CABLE WITH MINIMUM 12" SLACK @ 12" FROM EDGE OF
EQUIPMENT CABINETS, ACROSS WAVE GUIDE BRIDGE (IF APPLICABLE), UP
TO TOWER LEG (IF APPLICABLE), & DISTRIBUTE TO EACH ANTENNA
DEVICE. FURNISH AND INSTALL A MINIMUM OF (3) GROUND KITS PER
COAXIAL CABLE ACCORDING TO ELECTRICAL DRAWINGS. VERIFY NUMBER
OF ANTENNAS, CABLE & CABLE DIAMETER WITH PROJECT MANAGER.
ANTENNA DETAIL 6 ANTENNA & COAX GENERAL NOTES
22x34 SCALE: NTS 11x17 SCALE: NTS 22x34 SCALE: NTS 111x17 SCALE: NTS
SLOT FOR ADJUSTABLE
BAND CLAMP
GROUNDING
CLAMP ----_ 1/4" 20 HARDWARE r PUTTY TAPE
#6 GROUND LEAD /
GROUNDING
STRAP ASSEMBLY
FIGURE 1 FIGURE 2 FIGURE 3
ELECTRICAL TAPE
OVER MASTIC TAPE
FIGURE 4
COAXIAL CABLE GROUNDING
NTS
ADJUSTABLE
BAND CLAMP
~� GROUNDING CLAMP
FIGURE 5
ISSUED FOR.
CCONSTRUCTION
REV, -DATE: —ISSUED FOR: BY:
DRAWN BY:=CHK.: APV.:
JRF I ORA MWO
C CURRENT ISSUE DATE:
5 1lrGmc{1RF• 08-16-12
#6 GROUND LEAD
TWO HOLE COMPRESSION
CRIMP LUG (#6) TO
GROUND BAR
FIGURE 6
F<<�iI C,
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE
OTHERTHAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
RF DETAILS
'DRAWING NUMBER:
RF-1
0
CEI JOB NUMBER: 12-06007
22x34 SCALE: NTS
Style 1—Tower Top Mounted &Sector with 3 Quads (Sector1)
OVP
L/)
U
2
OVP
View from FRONT of Antenna
Antenna 3 Antenna 2, Antenna 1.
AWS LTE PCs
TX/RX AWS 2100 MHz RF
I... RX AWS 2100 MHz RF
TX/RX PCS 1900 MHz RF
W woo 41111111113111111111 RX PCS RF 1900 MHz RF
DC Power (-48 V)
Fiber Cable Single Mode
Hybrid Cable Solution
Over Voltage Protection Box
AISG Cable
Feeder Cable Kept for LMU
QMA to DIN Jumper for LMU
Dual Band TMA
T • Mobile•®
19807 NORTH CREEK PKWY
BOTHELI., WA 98011 OFFICE (425) 398-7600
RE�LC0M
PLANS PREPARED BY:
NEi-15TONE
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425AB7.1732 FAX:425.4871734
EMAIL: mQwmerslon ngr.mm
W W W CORNERSTONE-ENGR.COM
�PROJECTINFO:
ISSUED FOR:
CCONSTRUCTION
,,REV.-DATE:=ISSUED FOR: BY:
DRAWN BY:=CHK.: APV.:
JRF I DRA MWO
rCURRENT ISSUE DATE:
II{ 08-16-12
-PI/o 11,
=DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHERTHAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
_DRAWING TITLE:
RF DETAILS
DRAWING NUMBER:
RF-2 0
CEI JOB NUMBER: 12-06007