RE: File #09-102141-00-UP; USE PROCESS I DIRECTOR'S APPROVAL
AT&T Tammy Lane/WA415, 34301 9te Avenue South, Federal Way
Dear Ms. Todd:
The City's Planning Division has completed an administrative land use review of the proposed Personal
Wireless Service Facility (PWSF) antenna replacement on an existing American Tower Corp. owned
monopole on Parcel #202104-9157 at the address referenced above. The site is owned by the United
States Postal Service, and the tower is owned by American Tower Corp. The Process I application was
submitted and determined to be complete on June 10, 2009. Pursuant to Federal Way Revised Code
(FWRC) 19.55, "Process I — Director's Approval," your proposal is found to be consistent with the
provisions of Chapter 19.255 — Personal Wireless Service Facilities. Your Process I proposal is hereby
approved.
The Process I land use approval is supported by the following statement of facts:
1. Zoning & Land Use —The zoning designation for the subject property is Office Park (OP). PWSFs
are permitted in the OP zone pursuant to the zoning chart found in FWRC 19.215.100.
Review Process — According to submitted materials, the applicant proposes to replace three existing
antennas with three new models, replace six existing Tower Mounted Amplifiers (TMA) , add six
new model TMAs, and add three remote electrical tilts (RETs). The replacement of three antennas
with new models with a change in dimensions is not exempt from FWRC 19.255.010(3)(f) "routine
maintenance or repair" and requires a Process I Master Land Use Application. Please note the project
description states that this facility is located in the City right-of-way. After conducting a review of
this project it is clear this PWSF is not located in a right-of-way and was reviewed as such.
Cumulative Effects — The City must consider the cumulative visual effects of PWSFs mounted on
existing structures and/or located on a given permitted site in determining whether additional permits
may be granted so as to not adversely affect the visual character of the City. Currently, the antennas
are long and narrow (104"xl 1"x5") and are painted a non -reflective color to match the PSE pole. The
proposed antennas are smaller but wider (52"x22"xl 1") and will be painted the same color as the
existing antenna. As shown in the plans and elevations, the size change is not a substantial increase,
and the proposed PWSF will not adversely affect the visual character of the City.
4. State Environmental Policy Act (SEPA) — The project is exempt from SEPA review as it meets the
exemptions of WAC 197-11-800(25).
'Ws. Todd
July 10, 2009
Page 2
5. Additional Permits —No building permits are required for this proposal. However, an electrical permit
will be required. Please contact a Development Specialist at 253-835-2607 if you have questions
regarding the electrical permit application process.
6. Process I Thresholds —The proposed improvements do not reduce required parking, landscaping,
buffering, open space, or public areas; do not change the location of utilities or easements; and create
no impacts to sensitive areas or significant trees.
CLOSING
This decision shall not waive compliance with future City of Federal Way codes, policies, and standards
relating to this site. Final construction drawings will be reviewed for compliance with specific regulations
and other applicable City requirements. This Process I approval does not constitute approval of an
electrical permit.
The effective date of this decision is July 13, 2009, or three days from the date of this letter. Pursuant to
FWRC 19.55.050, any person who received notice of this administrative decision may appeal the decision
to the Federal Way Hearing Examiner by July 27, 2009. Any appeal must be in the form of a letter
delivered to the Department of Community Development Services with the established fee. The appeal
letter must contain a clear reference to the matter being appealed and a statement of the alleged errors in
the Director's decision, including the identification of specific findings and conclusions made by the
Director disputed by the person filing the appeal. No work on the proposal can commence until the end of
the appeal period. If an electrical permit is required, you may not commence work until you have been
issued the appropriate permit(s).
This Process I approval is valid for one year from the effective date of this decision. If no further action is
taken within one year, this decision will expire. A one-time, 180-day extension may be granted only if a
written request is submitted to the City's Department of Community Development Services (address
above) at least 30 days prior to the expiration of the decision.
If you have any questions regarding this decision, please contact Becky Chapin, Planning Intern, at 253-
835-2641 or Rebecca.Chapin@cityoffederalway.com.
Sincerely,
Greg Fewins, Director
Community Development Services
enc: Approved Site Plan
c: Rebecca Chapin, Planning Intern
09-102141
Doc I D. 50581
RECEIVED
Project Name: WA415 Tammy Lane/ATC
Location: 34301 91h Ave S. JUN 10 2009
PROJECT DESCRIPTION:
CITY OF FEDERAL WAY
CDS
AT&T is proposing to upgrade an existing wireless facility that is co -located on an
existing ATC-owned monopole in a commercial area. The site is a multi -carrier pole,
and AT&T leases space for its ground equipment on the same property upon which
the tower is located. The ground equipment is enclosed in a shelter.
The proposal consists of the following upgrades:
• Swap existing antenna (104"x11"x5") for new antenna (52"x22"x11"); see
A-2 for elevations
• Swap 6 of the existing TMA for new models and add 6 new model TMA; see
A-4.5, A-4.6 for specifications
• Add 3 remote electrical tilts (RETs); the RET allows the angle of the antenna
to be adjusted remotely and increases site maintenance efficiency; see A-
4.1, A.4-4 for specifications
COMPLIANCE WITH WIRELESS FACILITY DESIGN STANDARDS:
This facility is an existing facility located in the City right-of-way. While there is no
increase in the height of the structure or the number of antennas, the dimensions
of the antenna are changing and thus the proposal was determined to be outside of
the 19.255.010(f) exemptions. With the facility upgrade using the new antenna,
52"x22"x11", the facility will remain in compliance with the applicable design
standards for facilities located in the right-of-way.
The site as it exists exceeds the dimensions for a microcell or minor facility, and
would have received discretionary review under Process I/Director Approval. While
the proposed antennas do exceed the threshold for microcell dimensions, they do
not represent a substantial size increase from the existing approved antennas. The
existing antennas are long and narrow (103"x11"), and the proposed antennas are
half as long and wider (52"x22"). The new panels will not have significant visual
impact on the silhouette of the facility as a whole. The facility is a multi -carrier
monopole with three existing carriers, and AT&T's array is flush -mounted and
therefore closer to the pole than the second carrier; even with the wider antennas,
the proportions of the arrays will stay consistent with the existing look.
The proposed antennas are within the limits for maximum antenna height under the
development standards for building or structure mounted PWSFs in
19.255.020(1)(b), which limits panel antennas to 15 feet in height above the
existing structure. The proposed antennas will not add any height to the structure.
There will be no increase in the number of antennas, and the RETs and TMA are
installed on the backs of the antenna panels and will not impact the silhouette of
the facility.
MASTER LAND UR APPLICATION
DXrARTmxNT OF COHNI(INITY 1309LOPMENT. SERVICZS
ITT OP RECEIVED 97.1 S.
Pederal Way WA,010.634118
z,ed Oral Way JUN 10 2009
-www cftypffederalLyg,co'm
CITY OF FEDERAL WAY
: --
CDS
&PLICATTONNO(S) z0zV/
Date
roject-Name, 2.
WN-k�51 pt. vt�
ro.perrty- Address/Loenfion 61 gAl AMC,
arcel Numbers)
MHA &-e-4 4-OW to HHA at:. aii OW-Ak"L,-q. j)Kt*,sS
W,
Type of Permit Required
Annexaflon
Binding Site Plan
Boundary Line Adjustment.
Comp Plan/Rezone
Ladd $tidace Modification
Lot Line Elimination
Pkeapplidation Conference
�~Process I (Dijwor-s Approval)
Pr000s$. -11 (Site Plan Review)
Process HY (Projett Approval)
Procoss IV (.fleoring'ExomiiiersDecisibi!)
Process V (Qoasi-judicial RCZDne)
procog VI
SBPA-wz?rojert
GBPA, 041�
—ShQreli*i Vnianpe/CQndlOonal Use
Short Bubdivhion
Sub.dkVIS101T.
Variance: Commercial/Regidendal-
Required Wormation
-ZoningDesignatlon
Comprehensive Plan DesigdaflOn
Value of Existing ljnprovqrn6nts
'S i&M. e'Q'-!,Valhd of Proposed improvements
kiternadonal Building -Code: (lBQ:
tkn V ysa u" &1-0 c c u P a ri qy- Typ a
Typo
A.P. H watit
Mite Poul '-y-sS"r
Add 9! ies tkAv* S, 40
atylswe: stotl IV. A
Zip; 41 ' %VOL+ MP Phone. Z6t#
AY4" J�
Ageat (w diffa6xtthaxi Applioant)
-Natwi.
Address:
1P.
Phone,.
Signature;
Owner:
Name:
A4dress,,. fo
City/State:. -04 4
zip- 404-0/
Fhone-
-small:
signature:
"Sow
c al
q1.!OLIn4.1003 AU&st 11,2004 page I r I
f kAHan-(j1w0U0wr- Land OAp
-f --4~eA?5.f lwc
r
at&t
Your world. Delivered.
RTC BUILDING 3.16221 NE 72ND WAY
REDMOND, WA 98052
VICINITY MAP
SITE LOCATION 1\
reavrw�
�.:
DRIVING DIRECTIONS
GoodmanNetworks
Network Knowledge... Delivered
TAM MY LANE
34301 9tH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
WA415
AMERICAN TOWER CORP. SITE # 91531
GENERAL LOCATION MAP
SITE LOCATION
T
N
A
_ J=
6
S 31nh PI
. •: S 31Brh pI
..
FROM AT&T MOBILITY IN REDMOND: HEADING WEST ON SR-520 TO 1-405 SOUTH, TAKE 1-405 SOUTH TO 1-5 AND HEAD SOUTH ON 1-5. TAKE THE HWY 509 EXIT
WESTBOUND, TO INTERSECTION WITH 1ST WAY SOUTH. AT 1ST WAY SOUTH, TAKE A LEFT AND HEAD SOUTH. CONTINUE TO INTERSECTION WITH S. 336TH
STREET. TURN LEFT, HEADING EAST TO INTERSECTION WITH 4TH AVE S. CONTINUE UNTIL DRIVEWAY FOR US MAIL IS ON RIGHT (WEST SIDE). TURN IN AND
SITE IS ON NORTH SIDE OF THE PROPERTY
APPROVAL/SIGN
OFF OF
CONSTRUCTION
DRAWINGS
CONSULTANT GROUP SIGN OFF
DATE
SIGNATURE
AT&T SIGN OFF
DATE
SIGNATURE
CONSTRUCTION COORDINATOR
RF ENGINEER
LANDLORD'S REPRESENTATIVE
INTERCONNECT
PROJECT MANAGER
SITE ACQUISITION
ZONING
OPERATIONS
COMPLIANCE
CONSTRUCTION MANAGER
PROJECT MANAGER
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
PROJECT INFORMATION
APPLICANT:
PROPERTY OWNER:
AT&T MOBILITY CORPORATION
AMERICAN TOWER CORP.
16221 NE 72nd WAY, RTC 3
116 HUNTINGTON AVE, 11th FLOOR
REDMOND, WA 98052
BOSTON, MA 02116
PHONE: (949) 442-6400 x101
PROJECT ENGINEER:
CORNERSTONE ENGINEERING, INC.
PROJECT CONSULTANTS:
16928 WOODINVILLE-REDMOND RD N.E. SUITE 210
GOODMAN NETWORKS
WOODINVILLE, WA 98072
8815 122ND AVE. NE
MARK W OLSON, P.E.
KIRKLAND, WA 98033
PH: (425) 487-1732
FAX: (425) 487-1734
PROJECT MANAGER:
CONTACT: ERIK ZITTLEMAN
ezittl eman @ good mannetworks. corn
SITE AQUISITION
CONTACT: REYNATAFEYTON
rfeyton@ptswa.com
ZONING AGENT:
CODE fNFORMATIM.
CONTACT: SUNNY YIM
ZONING CLASSIFICATION: C-COMMERCIAL
syim@ptsw&oom
BUILDING CODE: IBC2006
CONSTRUC"I'lON MANAGER:
CONSTRUCTION TYPE: TELECOMMUNICATIONS
CONTACT: JIM BELLAR
OCCUPANCY: UNOCCUPIED GROUP "U"
jbellar@goodmannetworks.com
JURISDICTION: FEDERAL WAY
PARCEL NUMBER:
PROPOSED BUILDING USE: TELECOMM
2021049157
SITE LOCATION: BASED ON NAP-931
AREA OF PARCEL:
LATITUDE: 47` 17' 46.9" N (47.29636)
2.245.518 SQ. FT
(51,55 ACRES)
LONGITUDE: 122* 19' 34.9" W (122.32636)
TOP OF STRUCTURE: 120'-0" (MONOPOLE)
NEW IMPERVIOUS AREA:
BASE OF STRUCTURE: 0'-0" AMSL (ASSUMED)
0 SO. FT.
PROJECTAREA:
0 SQ. FT.
GENERAL INFORMATION:
1. PARKING REQUIREMENTS ARE UNCHANGED, (NON ASSIGNEDTECH PARKING)
2. TRAFFIC IS UNAFFECTED.
3. NO SIGNAGE IS PROPOSED,
PROJECT DESCRIPTION:
THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED
TELECOMMUNICATIONS FACILITY. CONSISTING OF THE REMOVAL AND REPLACEMENT OF (3)
PANEL ANTENNAS AND THE ADDITION OF (3) RET'S, REMOVAL AND REPLACEMENT OF (6)
MHA'S ALONG WITH THE ADDITION OF (6) NEW MHNS TO AN EXISTING 120-FOOT STEEL
MONOPOLE.
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION
DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR
DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT&T
WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED.
DRAWING INDEX
DWG.
N0.
DESCRIPTION
T-1
TITLE SHEET
G-1
GENERAL NOTES
A-1
ENLARGED SITEPLAN
A-2
EXISTING & PROPOSED WEST ELEVATIONS
A-3
PROPOSED AND EXISTING ANTENNA PLANS
A-4
ANTENNA DETAILS
A-6
ANTENNA SWEEP TEST & COAX COLOR CODING
I LEGAL DESCRIPTION I
FOR OF N 1/2 DAF: BEG CENTER OF SEC; TH N 01-16-46 E
ALG N-S C/L 360.82 FT TH N 88-46-14 W 330 FT TH S 01-16-46
W 179.36FTTONLNOFS181.5FTOFSDN1/2THN88-46-40
W 220 FT TH S 01-16-46 W 181.5 FT TO ENV 1/4 LN SD SEC; TH
N 88-46-40 W 521.96 FT TO A PT S 88-46-40 E 1544,35 FT FIR W
1/4 CDR SD SEC TH N 01-10-59 E 712.14 FT TH N 53-40-00 W
543.88 FT TH N 36-20-00 E 310 FT; TH ON CURVE TO LEFT RAD
1250 FT THROUGH C/A 18-47-35 ARC DIST OF 410 FT TH S
72-27-35 E 789.85 FT TH S 35-00-00 E 134.66 FT TO S LN OF NE
1/4 OF NW 1/4 TH ON SD S LN & S LN OF NW 1/4 OF NE 1/4 S
88-45-47 E 795.73 FT TAP ON 1130 FT RAID CURVE WHOSE
CENTER PT BEARS S 84-52-30 E TH SLY ALG SD CURVE
THROUGH C/A 09-57-30 ARC DIST OF 196.40 FT TH S O4-50-00
E 460 FT TAP OF 810 FT RADIUS CURVE TO RGT TH ON SD
CURVE THROUGH C/A 30-00-00 ARC DIST OF 424.12.FT TH S
25-10-00 W 271.12 F7 TO EIW CIL SD on k � D
88.46.40 W 348,35 FT TO CENTER SD 0 V C
J U N 10 2009
CITY OF FEDERAL W
0 at&t
Your world. Delivered.
~ PROJECT CONSULTANTS:
GoodmanNetworks
PLANS PREPARED BY:
�GPRrJI��['�rYe
■r� aHal.raw�wo, Ixe.
16928 WOODINVILLE-REDMOND RD NE. SUITE 210
WOOD INVILLE, WA 9BO72
PHONE: 425487.1732 FAX: 4254671734
EMAIL: cei(Zrners0necng,.
W W W CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR:
FINAL CUS
REV:= DATE: = DESCRIPTION: =BY:= CK:�
0
0
04-13-09
ISSUE FOR FINAL
JRF
MWO
AL3-26-09
ISSUE FOR
CLIENT REVIEW
DRA
MWO
L DRAWN BY: CHK.: —Arv_
ORA MWO I MWO
C CURRENT ISSUEDATE.
04-13-09
r LICENSURE:
W 1V
:DRAWING INFORMATION:
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSION& ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
= DRAWING TITLE:
TITLE SHEET
_DRAWING NUMBER:
T-1 0
CEI JOB NUMBER: 09.69D43
GENERAL NOTES:
1 DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS
SET OF DOCULIEWS IS INTENDED TO BE USEF) FOR OIAGRAL1=MPURPOSESONLY,
UNLESS NOTED OTHER4VtSE. TKE43F _RAL CONTRAC7OR5 SCOPE OF L4ORIC SNAIL
INCLUDE FURNISHING ALL MATERIALS. EQUiPME NT, LASOR AND ANY REOUI RELiENTS
DEEI.IEO NECESSARY TO COMPLETE PROJECT AS, DESCRIBED IN THE PAAWMaS AND
OWNER'S PROJECT MANUAL
2 PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB
SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED
PROJECT CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE
CONSTRUCTIOWCONTRACTOOCUMENIS TO VERIFY FIELD CONDITIONSAND CONFGRIA
THAT THE PROJECT WILL BE ACCOMPU$HED AS SHOWN PRIOR TO PROLE BOINO VNRM
CONSTRUCTION- ANY ERRORS. OMISSIONS. OR DISCREPANCIES SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING
3 THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE
CONSTRUCTION AND CONTRACT DOCLII.IENTS THE COMPLETE. SCOPE OF WORK
CONTRACTORS BIDDING THE JOB ARE NEVERTMELESSCAUTKINED THAT MINOR
O1,IIS'IONS DR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT
E7(CUSE SAID COHTRAOTOR FROI.4 COMPLETING THE PRGJEC7 AND R.SPROVEIAE NTS IN
ACCORDANCE WITH THE 1NTENT OF THESE DOCUMENT$- THE BIDDER SHALL BEAR THE
RESPONSBILRY OF NOTIFYING IIN WRITING) THE ARCWfEe;ENCINEER OF ANY
CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S
PROPOSAL IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE
MORE COSTLY OR EXTENSIVE WORK UNLESS DIRECTED OTHERWISE
A THE CONTRACTOR SHALL SUPERVISE AND OLRECT THE PROJECT DESCMED IN THE
CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL
CONSTRUCTION MEANS- METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR
COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT,
5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO
MANUFACTURER'SNENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE
LOCAL CODES OR ORDINANCES TAKE PRECEDENCE
6 ALL WORKPFRFORMED ON THE PROJECT AND MATERLALSINSTALLED SHALLSE IN
STRICT ACCORDANCE MTN ALL APPLICABLE CODES, REGULATIONS. AJOORDINANCES.
CONTRAGTORSHALL GIVE ALL NOTICES AND COMPLY VWK ALL LAWS, ORDINANCES,
RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL
AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL
CODES BEARING ON THE PERFORMANCE OF THE WORK
7. GENERAL CONTRACTOR SHALL PROVIDE. AT THE PROJECTSITE, A FULL SET OF
CONSTRUCTION DOCUMENTS UPDATED 15TDI THE LATEST REVISIONS AND ADDENDA
OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS
SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR
CONSTRUCTION' AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT'S SIGNED WET
STAMP.
8, THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE
NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE
9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE
MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT
SITE,
10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT
LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF
PROJECT AREA DURING CONSTRUCTION,
11, CONTRACTORSNALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENM EASEMENTS, PAVING. CURBING, ETC. DURING CONSTRUCTION, UPON
COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE
OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING
CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH CONTRACTOR
SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR
PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS,
DUST, OR SMUDGES OF ANY NATURE,
13 THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED
WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED
BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
14 THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO
AVOID DISTURBING NORMAL BUSINESS
15 THE CONTRACTOR SHALL PROVIDE AT&T WIRELESS, LLC. PROPER INSURANCE
CERTIFICATES NAMING AT&T WIRELESS, LLC. AS ADDITIONAL INSURED, AND AT&T
WIRELESS, LLC, PROOF OF LICENSE(S) AND PE & PD INSURANCE.
16 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL
INSPECTIONS.
IT CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY
INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY
LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION DIAL 611
1& CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND
SUBMIT TO AT&T WIRELESS, LLC ALONG WITH REDLINED CONSTRUCTION SET.
19. CONTRACTOR TO DOCUM EN7 ALL CHANGES MADE IN THE FIELD BY MARKING UP
(REDLINING) THEAPPROVEO CONSTRUCTION SET AND SUBMITTING THE REDLINED SET
TO AT&T WIRELESS, LLC. UPON COMPLETION.
20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR
PARTICIPATION IN BID WALK
21, GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER
COMPANY AS REQUIRED, CONTRACTOR TO REPORT POWER INSTALLATION
COORDINATION SOLUTION(S)TO NETWORK CARRIER REPRESENTATIVE, PROJECT
CONSTRUCTION MANAGER AND ARCHITECT.
22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT. MUST BE APPROVED BY AT&T
CONSTRUCTION MANAGER
23. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES
WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL
CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING
CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION
TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING
CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE
BREACH OF ROOFING INTEGRITY.
24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN
CONCEALED (SHROUDED) SUPPORT FRAMES ORTRIPODS, THE GENERAL CONTRACTOR
SHALL COORDINATE WITH THE FRP DESIGNERIPABR ICATOR TO ENSURE THAT THE
FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNAtCOfXISTING EXTERIOR
BUILDING FACADE MATERIALS, TEXTURES, AND COLORS THE CONTRACTOR SHALL
FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP
CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL
ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTO
SIMULATIONS SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR.
CONSTRUCTION COORDINATOR. AND ARCHITECT PRIOR TO FABRICATION AND
CONSTRUCTION.
GENERAL NOTES CON I
t RE
25 fN THE CASE OF ROOFTOP SOLUTK]PfS FOR EIXNPMENT AND'OR ANTENNA FRA}.TES YHE ANCHORING TO A CONCRETE ROOF SLAB IS RE GUTAED. CONTRACTORS SHALL CONFIRM (PRIOR
TO SUBTAITYI NG BID) WITH CONSULTING CONSTRUCTION COOROMA70R AND ARCHITECT THE
PRESENCE OF POSSTTENMN TENDONS %MTHIN THE ROOF SLAB -RESULTING FROM AN
UNDOGVMENTED DESIGN CHANGE 1H THE EXISTING BVILDING'AS-BUILT DRAWING $Es'' HAVING
INDICATED AN ORIOWAL DESIGN SOLUTION OF REINFORCED CONCRETE W7 EMBEDDED STEEL
AEBAR. IN THE EVERT POST TENSLGN SLAB SOLUTION ISPRESENT-CONTRACTOR SHALL INCLUDE
PRGVISIGNS FOR X-RAY PROGEOVRES (INCLUDED IN SLDI FOR ALL PEHETRATION AREAS 74-0 RE
ANCHORING OCCURS
26 GENERAL& SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL
CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE MY" (WHERE APPLiCA8LET PLASTIC ZIP
1I85 SHALL NOT BE PERMITTED FOR USE ON AT&T PROJECTS. RECOMMENDED MANUFACTURE
SHALL SE: PANDUITCORP- METAL LOCKING TI£51.1(JDEL NO. ML74S�,P UNDER SERIFS41A (OR
EQUAL) PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA. WA
DESIGN CRITERIA:
1. THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE 2006 WITH WASHINGTON STATE BUILDING CODE
AMENDMENTS (20061BC)
Z DESIGN LOADS:.
DESIGN DATA FOR KING COUNTY. WA:
-ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION)
-BASIC WIND SPEED 85 MPH (3 SEC GUST)
-WIND EXPOSURE B
CONCRETE NOTES:
I. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318
2 CONCRETE SHALL BE MIXED, PROPORTIONED. CONVEYED AND PLACED IN ACCORDANCE
WITH CHAPTER 19 OF THE 20061BC. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL
BE AS FOLLOWS
TYPE OF CONSTRUCTION 26 DAY STRENGTHS W/C MINIMUM CEMENT
(rc) RATIO CONTENT
A SLABS ON GRADE PER CUBIC YARD
TOPPING SLABS
CONCRETE PIERS 2.400 PSI .45 5112 SACKS
B. ALL STRUCTURAL CONCRETE 4,000 PSI `_ .45 6 1/2 SACKS
EXCEPT WALLS
C. CONCRETE WALLS 4.000 PSI '_ .45 6 V2 SACKS
CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O.
3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE
METHODS AND PROCEDURES OF CONCRETE PLACEMENT-
4 ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE
AIR -ENTRAINED WITH AN AIR{HTRAININOAGEHTCONFORMINC TO RS'ILI C200, C494,
C618, C9&4AND C10L7. TOTAL AIR CONTEN7SHALL BE IN ACCORDANCE WITH TABLE
1904 2 1 OF THE 20061BC
5 REI NFORGNO STEEL SHALL CONFORM TOASTId A615 NINCLUDING SUPPLEMENT $1I.
GRADE 60, Iy�00,006 PSI EXCEPTIONS. ANY BARS SPECIFICALLY SO NOTED OH THE
CRAWINGS SHALL B£ GRADE 40, lr40.000 PSI GRADE 00 REINFORCWG BARS INDICATED
ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A708 REINFORCING
COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY
REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN
A W.S D14 ARE SUBMITTED
6, RE WFORCING S TIE EL SHALL BE DETAILED (INCLUDING NOOKS AND BENDS) IN
ACCOR DANCE VATH AC &15 AND $36. LAP ALL CONTINUOUS REINFORC£IAENT AT LEAST
30 GAR DIAMETERS OR A MNNIMUM OF Z-O". PROVIDE CORNER BARS AT ALL WALL AND
FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERSORA
MINIMUM OF 2'-O". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF B' AT
SIDES AND ENDS.
7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185
B. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60,
fy=60.000 PSI.
9 NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT
UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT,
10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
• FOOTINGS AND OTHER UNFORMED
SURFACES, EARTH FACE 3"
• FORMED SURFACES EXPOSED
TO EARTH OR WEATHER (#6 BARS OR LARGER) 2"
(#5 BARS OR SMALLER) 1 1/2"
- SLABS AND WALLS (INTERIOR FACE) 3/4
11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS
12. ANCHOR BOLTS TO CONFORM TO ASTM A307
13 NONSHRIHK GROV7 SHALL BE FUAN1SHEO BY AN APPROVED MANUFACTMER AND
SHALL BE 1.11)LEO AND PLACED IN STRICT ACCORDANCE WITH THE UANUFACTURER'S
PUBLISHED RECOMMEWAX4115 GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE
MATERIAL ON WHICH IT IS PLACED (3.000 PSI MINIMUM)
14. ALL EXPANSION ANCHORS TO BE HILTI BRAND ADHESIVE ANCHORS REQUIRE TESTING
TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER
STRUCTURAL STEEL NOTES:
1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT
FOR REVIEW PRIOR TO FABRICATION.
2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING,
HIGH STRENGTH FIELD BMTING, EXPANSION BOLTS. AND THREADED EXPANSION
ANCMOF75) SHALL BE BASEOON THE A I:S I. "SPECIFICATION FOR THE DE510N.
FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR &HLDIWGS' LATEST EDITION
x(P$RVISION SHALL BE IN ACCORDANCE WITH 'AM ISC CHAPTER 22. BY A QUALIFIED
TESTING AGENCY DESIGNATED BY THE CONSULTANT THE CONSULTANT SHALL BE
FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS
3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS:
TYPE OF MEMBER
A WIDE FLANGE SHAPE ASTMA-99Z Fy 50 KSI
R OTHER SHAPE, PLATES AND ROD ASTM A36, Fy 36 KSI
C PIPE COLUMNS ASTM A53. Fy 35 KSI
D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI
E- ANCHOR BOLTS ASTM A307
F. CONNECTION BOLTS ASTM A325
4 ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00
5 ALL WELDING SHALL BE W CONFORMANCE 1L•ITH A I S I AND AWS STANDARDS AND SHALL
BE PERFORFAEO BY Yf.A R.O. CE RTDIED WELDERS USINO E70 XX ELECTRODES. ONLY
PRECKJALBrKiD;MOE (AS DEFINED BY AWS) SHALL BE USED. VELDING OF GRADE W
REINFORCING BARS IIF REQUIREOI SHALL BE PER RNWED USING LOW HYDROGEN
ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS IF REQUIRED) SHALL BE
PERFORATED USING E70 XX ELECTRODES IVELOING WITHIN 4' OF COLD BENDS iH
REINF ORGNG STEEL IS NOT PERLITRE D. SEE REINFORCING NOTE FOR MATERIAL
REQUIREMENTS OF WELDED BARS
6, COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE. SIZE, AND GAGE
SHOWN ON7HE PLANS PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL
COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE AI.S.I. 'SPECIFICATION FOR THE
DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS"
7- BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (314" DIA )AND SHALL
HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE
& NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/9" DIA ASTM A307
BOLTS UNLESS NOTED OTHERWISE
9. ALL STEEL WOR K SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN &
CONSTRLICTIDIN SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED
OTHERWISE.
1Q ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE
11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH
PAINT) OR APPROVED EQUAL
TOWER/POLE NOTES:
1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA
LOADING IS TO BE DONE BY OTHERS
Z PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL AND
FUTURE ANTENNAS ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE
CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS
ABBREVIATED ROOF TOP SAFETY PROCEDURES
(WHEN APPLICABLE):
(AS PER "ACCIDENT PREVENTION PROGRAM' -BY PERMISSION OF WREN CONSTRUCTION,
INC.-03/01199)
FALL PROTECTION METHODS AND EQUIPMENT
ROOF TOP INSTALLATIONS
1. FOR WORK IS BEING PERFORMED WITHIN 25- OF AN UNPROTECTED ROOF EDGE.
THE CONSTRUCTION SUPEAVI50R SHALL DESIGNATE A TRAINED SAFETY MONITOR
TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION
WORKERS
2 SAFETY K40NITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I E.
BACKING UP TOWARD A ROOF EDGE, ETC) OR UNSAFE ACTIVITIES THE SAFETY
MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUALAND VERBAL
DISTANCE OF THE CONSTRUCTION WORKERS
3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN V OR LESS OF AN
UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE
4. SAFETY LINE SHALL BE MINIMUM h" DIAMETER NYLON. WITH A NOMINAL TENSILE
STRENGTH OF 5400 LBS
5. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE
STRUCTURE
6. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO
REACH EDGE OF ROOF, BUT NOT BEYOND
7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS
8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION
EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES.
INCLUDING:
INSPECTION OF CONSTRUCTION AREA FOR HAZARDS
USE OF AN INSPECTION CHECKLIST
INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS
REPORTING AND DOCUMENTING ANY HAZARDS
REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION
POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN
RECEIVING AN UNBIASED RENEW OF ONE'S OWN WORK AREA BY ANOTHER
COWORKER SAFETY REPRESENTATIVE
REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL
NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION
REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY T05YFSLEAECTORS.
EQUIPMENT INSTALLERS, AND TOWER.ROOF TOP CONTRACTORSSUSCONTRACTORS
29 OFF; sBn'.500 - SCOPE, APPLICATION. AND WWI TIONS
29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION
19 CFR 1926.502 -FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES
YMBOLS AND ABBREVIATIONS
A/C
AIR CONDITIONING
LBS
POUNDS
AGL
ABOVE FINISH GRADE
MAX
MAXIMUM
APPROX
APPROXIMATELY
MECH
MECHANICAL
MTL
METAL
BLDG
BUILDING
MFR
MANUFACTURE
ELK
BLOCKING
MGR
MANAGER
MIN
MINIMUM
CLG
CEILING
MISC
MISCELLANEOUS
CUR
CLEAR
CONC
CONCRETE
NA
NOT APPLICABLE
CONST
CONSTRUCTION
NIC
NOT IN CONTRACT
CONT
CONTINUOUS
NTS
NOT TO SCALE
DBL
DOUBLE
OC
ON CENTER
DIA
DIAMETER
OD
OUTSIDE DIAMETER
DIAG
DIAGONAL
DIN
DOWN
PLYWD
PLYWOOD
DIET
DETAIL
PROJ
PROJECT
DWG
DRAWING
PROP
PROPERTY
PT
PRESSURE TREATED
EA
EACH
REG
REQUIRED
ELEV
ELEVATION
RM
ROOM
ELEC
ELECTRICAL
RO
ROUGH OPENING
EQ
EQUAL
EQUIP
EQUIPMENT
SHT
SHEET
EXT
EXTERIOR
SIM
SIMILAR
SPEC
SPECIFICATION
RN
FINISH
SF
SQUARE FOOT
FLUOR
FLOURESCENT
SS
STAINLESS STEEL
FUR
FLOOR
STL
STEEL
FT
FOOT
STRUCT
STRUCTURAL
STD
STUD
GA
GAUGE
SUSP
SUSPENDED
GALV
GALVANIZED
GC
GENERALCONTRACTOR
THRU
THROUGH
GRND
GROUND
TIMING
TINNED
GYP BD
GYPSUM WALL BOARD
TYP
TYPICAL
HORZ
HORIZONTAL
UNO
UNLESSNOTED
HR
HOUR
OTHERWISE
HT
HEIGHT
HVAC
HEATING
VERT
VERTICAL
VENTILATION
VIF
VERIFY IN FIELD
AIR CONDITIONING
W/
WITH
ID
INSIDE DIAMETER
W/O
WITHOUT
IN
INCH
WP
WATER PROOF
INFO
INFORMATION
INSUL
INSULATION
TNT
INTERIOR
IBC
INTERNATIONAL
BUILDING CODE
- T
T-
TELEPHONE
-p
P-
POWER
- - - -
- - - - - - -
GROUND WIRE
-COAX
COAX-
COAXIAL CABLE
®
ANTENNA
rL
CENTERLINE
(E)
EXISTING
x
DETAIL NUMBER
SHEET NUMBER
*� at&t
Your world. Delivered.
PROJECT CONSULTANTS:
GoodmanNetworks
PLANS PREPARED BY:
�E ¢ O� NEr�EiIoONE
16926 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE 425,487.1732 FAX: 425487.1734
EMAIL: ceiCcornerslone-gr com
WWW. CORNERSTONE-ENGR COM
" PROJECT INFO:
ISSUED FOR:
IFINAL CDIS
REV:= DATE:= DESCRIPTION: -BY =CK:�
0
04-13-09
ISSUE FOR FINAL
CD'S
JRF
MWO
Qq
03-26-09
ISSUE FOR
CLIENT REVIEW
DRA
MWO
L DRAWN BY: CHK:-ARV , -
DRA MWp MWO
CURRENT ISSUE DATE.
04-13-09
-UKAWING INY VKNIAI IVIY:
DO NOT SCALE DRAWINGS, CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED.
DRAWING TITLE:
GENERAL NOTES
DRAWING NUMBER-
G-1 0
CEI JOB NUMBER: 09.69043
(E) PARKING LOT AND
DRIVEWAY
(E) CURB
(E) BRUSH AND TREES
(E) AT&T 10'-O"x16-0"
EQUIPMENT SHELTER
NOTTE:E' : f
OTHER CARRIER ANTENNA ARRAYS
NOT SHOWN FOR CLARITY
ENLARGED SITE PLAN
22x34 SCALE: 3I8" = V-0" 11107 SCALE: 3/16" _
k91CU;r
I�
(E) UTILITY H-FRAME
(E) ICE BRIDGE
(E) BRUSH AND TREES
THIS IS NOT A SURVEY
ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM
EXISTING DRAWINGS AND ARE APPROXIMATE.
(E) 12'-0- DUAL GATE
(E) 6-0" TALL CHAIN LINK (E) BRUSH ANDTREE LINE
FENCE WITH BARBED WIRE
PROPOSED REPLACEMENT
PANEL ANTENNA ANDREW
QBXLH-6565-VTM {
A�
(E) 120'-0" HIGH STEEL
MONOPOLE
(E) OTHER CARRIER
CONCRETE SLAB
n+
PLAN NORTH
1
at&t
Your world. Delivered.
= PROJECT CONSULTANTS:
QGoodmanNetworks
PLANS PREPARED BY:
�CC7iRNER5Y0NC.
-� ■ry OI INC.
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE 425.467.1732 FAX:425487.1734
EMAIL: cei@cornerstone ngrcom
WWW CORNERSTONE-ENGR,COM
PROJECT INFO:
rL ISSUED FOR:
LFINAL MIS
REV:=DATE:—DESCRIPTION:=BY:=Ci( —1
p
04-13-09
ISSUE FOR FINAL
CD'S
JRF
MWO
A
03-26-09
ISSUE FOR
I CLIENT REVIEW
DRA
MWO
DRAWN BY: CHK:=APV.:
DRA MWO MWO
CURRENT ISSUE DATE:
11 04-13-09
DO NOT SCALE DRAWINGS" CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED,
DRAWING TITLE:
ENLARGED SITE PLAN
DRAWING NUM9ER:
A- 00
CE1 JOB NUMBER 09-69043
PROPOSED TMA LGP 21401
MOUNTED BEHIND ANTENNA
TOP OF (E)
120'-0" AGL
MONOPOLE
RAD CENTER OF AT&T ANTENNAS
116'-D" AGL
PROPOSED REPLACEMENT
PANEL ANTENNA ANDRfW
OBXLH-6565 VTM 1
A�
rr
hRAD CENTER OF (E) ANTENNAS:
r 9r-T AGL -
RAD CENTER OF (E) ANTENNAS _
'1I!k93'-0" AGL
RAD CENTER O_F(E)ANTENNAS
—
_0RAO CENTER OF IE)ANTENNAS
79'-9' AGL —
GRADE
PROPOSED WEST ELEVATION
22x34 SCALE: 1/8" = 1'-V I 11x17 SCALE: 1116" = 1'-0"
NOTE:
EXISTING ANTENNA MOUNTING
HARDWARE TO BE REUSED
(E) AT&T ANTENNA MOUNTING
HARDWARE
(E) AT&T ANTENNA
PROPOSED RET (TYP) A 4
(E) OTHER WIRELESS CARRIER
r ANTENNA ARRAY
(E) OTHER WIRELESS CARRIER
ANTENNA ARRAY
(E) OTHER WIRELESS CARRIER
ANTENNA ARRAY
(E) 120'-0" HIGH STEEL
MONOPOLE
SHELTER
(E) CHAIN -LINK FENCE
W/ (3) STRAND BARBED WIRE
,(� TOP OF (E) MONOPOLE
4� 120'-0" AGL
RA_D CENTER OF AT&T ANTE_NNAS
�' 116'-0" AGL J
BRAD CENTER OF (E) ANTENNAS
RAD CENTER OF (E) ANTENNAS�83'•p"
'RAD CENTER OF (E) ANTENNAS _
83'-0" AGL
RAD CENTER OF(E)ANTENNAS
21 EXISTING WEST ELEVATION
2204 SCALE- 118" = 1'.p' 11 07 SCALE: MW = VAY
(E) AT&T ANTENNA MOUNTING
HARDWARE
(E) OTHER WIRELESS CARRIER
ANTENNA ARRAY
(E) OTHER WIRELESS CARRIER
ANTENNA ARRAY
(E) OTHER WIRELESS CARRIER
ANTENNA ARRAY
IPMENT SHELTER
(E) CHAIN -LINK FENCE
W/ (3) STRAND BARBED WIRE
at&t
Your world. Delivered.
~ PROJECT CONSULTANTS:
GoodmanNetworks
PLANS PREPARED BY:
�� a Or�NeFtS TONE
NEERING. INC.
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 9Bo72
PHONE: 425,467-1732 FAX: 425,487.1734
EMAIL: cei@cornerstone—gr com
WWW CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR:
FINAL CUS
REV:= DATE: =DESCRIPTION:=BY:=CK:—I
p
04-13-09
ISSUE FOR FINAL
CD'S
JRF
MWO
QA
03-26-09
ISSUE FOR
CLIENT REVIEW
DRA
MWO
DRAWN BY: CHK.:=APV.:
IILL DRA MWD I MWO
CURRENT ISSUE DATE:
04-13-09
LICENSURE:
DRAWING INFORMATION:
DO IFY NOT SCALE DRAWINGS CONTRACTOR MUST VER
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION,
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
DRAWING TITLE:
EXISTING & PROPOSED
WEST ELEVATION
DRAWING NUMBER:
A-2 0
CEl JOB NUMBER 09.690-43
SCHEDULES
2204 SCALE: NTS
APPURTENANCES
ITEM
NEW
EXISTING
REMAIN
REPLACE
TOTAL
ANTENNA
3
3
0
3
3
TMA
6
6
0
6
12
RET
3
9
9
0
12
11x17 SCALE: NTS
SECTOR "Z'
S�
PROPOSED REPLACEMENT
PANEL ANTENNA ANDREW
QBXLH-6565-VTM 1
(TYP OF 3) A ..
ry
SECTOR "Y"
z�
PROPOSED ANTENNA PLAN
�i
SECTOR "X"
(E) 120'-0" HIGH
STEEL MONOPOLE
PLAN NORTH
COAX SCHEDULE
SECTOR
LENGTH
#OF COAX
DIAMETER
PLACEMENT
SECTOR X
138'-0"
6 (E)
7/8"
INSIDE TOWER
SECTOR Y
138'-0"
6 (E)
7/8"
INSIDE TOWER
SECTOR
138'-0"
6(E)
7/6''
INSIDETOWER
RET
138'-0"
1 (N)
3/8"0
INSIDETOWER
SECTOR "r
X .
(E) PANEL ANTENNA
(TO BE REPLACED)
(E) PANEL ANTENN<
(TO BE REPLACED)
YCTOR"Y"
2 EXISTINGNTENAN:LANNTENLAN22x34 SCALESCALE
$g
�����
SECTOR "X"
(E) PANEL ANTENNA
(TO BE REPLACED)
(E) 120'-0" HIGH
STEEL MONOPOLE
PLAN NORTH
K
at&t
Your world. Delivered.
PROJECT CONSULTANTS:
GoodmanNetworks
PLANS PREPARED BY:
�[ORNERSVON£
�� Lwerfre�Rr%4, rHc-
16928 WOODINVILLE-REDMOND RD NE SUITE 210
WOODINVILLE. WA 98072
PHONE 425,487.1732 FAX:4254871734
EMAIL: cei@cornersI0ne ngrcom
W W W. CORNERSTONE-ENGR COM
PROJECT INFO:
ISSUED FOR:
[I L.FINAL CD'S
L. REV:= DATE: =DESCRIPTION:—BY:=CK:-7
Qp
04-13-09
ISSUE FOR FINAL
JRF
MWO
Q03-26-09
A
ISSUE FOR
CLIENT REVIEW
DRA
MWO
DRAWN BY: CHK.:=APV.:
DRA MWO MWO
r CURRENT ISSUE DATE:
II`L 04-13-09
LICENSURE:
W' O[
y � r
� 3..
YYt7
E7fpIRES 0715571
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
DRAWING TITLE:
EXISTING AND PROPOSED
ANTENNA PLANS
DRAWING NUMBER:
A-3 0
CEI JOB NUMBER 09.89043
NTS 111x17
NOTES:
1. TMA IS A WEATHERPROOFED ENCLOSURE RATED TO IP65.
2. BOND TMA GROUND STUD TO GROUND BAR WITH 6AWG GROUND WIRE.
3, PROVIDE SUFFICIENT LENGTH OF JUMPER TO ALLOW FOR PROPER APPLICATION
OF WEATHER PROOFING AT ANTENNA AND TMA CONNECTIONS,
4. IF POSSIBLE, TMA SHALL BE MOUNTED BEHIND ANTENNA TO MINIMIZE WIND LOADING ON
STRUCTURE
5 TMA SHALL BE MOUNTED VERTICALLY.
METAL STRAP
SUBCONTRACTOR
TO PROVIDE (TYP)JUNIPER TO ANTENNA
TMA �wr
GROUND SCREW
°n GROUND WIRE TO ANTENNA
ANTENNA MOUNTING PIPE (TYP) GROUND BAR (SEE NOTE 2)
JUMPER TO MAIN COAX
FRONT VIEW
JUMPER TO ANTENNA
METAL STRAP
SUBCONTRACTOR
TMA TO PROVIDE (TYP)
GROUND WIRE TO ANTENNA ANTENNA MOUNTING PIPE (TYP)
GROUND BAR (SEE NOTE 2) -
JUMPER TO MAIN COAX
SIDE VIEW
TMA MOUNTING DETAIL
N_fS 11 IX17 SCALE: NTS
(E) ANTENNA F
PRIMARY LOCI
OF TMA, AS PE
CONDITIONS.
ANTENNA AS PER
ANTENNA SCHEDULE
RET AS REQ'D
COAXJUMPER
SUPPORT
COAX TO JUM
KIT, GROUNDI
AND CABINET.
TMA ATTACHMENT
9 5/16"
9 1/16"
1 1/2" II :3"
850 ANT 1900 ANT
POWERWAVE
I
iO
N
I
THIS END DOIA
BTS
2 5/8"
6 TMA DETAIL
22x34 SCALE- 3" = 1'-0"
5 3/16"
5 15/16"
318"0 (8x)
GROUND SCREW M8
CONNECTOR 7-16
FEMALE (3x)
1x17 SCALE: 1 1/2" = l'-0-
2 3/8" O.D.
GALV PIPE MAST
ANTENNA---
3 ANTENNA MOUNTING DETAIL
22x34 SCALE: NTS 11x17 SCALE: NTS
5
2
RET DETAIL 4
22x34 SCALE: NTS 111x17 SCALE: NTS
1'-1�
m O
v
v
f�
FRONT BACK SIDE
ANDREW ANTENNA:
QBXLH-6565A-VTM
TOP
ANTENNA DETAIL W/ RET'S ATTACHED
22x34 SCALE: 112" = T-0" I 1107 SCALE: 114-= V-0-
at&t
Your world. Delivered.
rr[vd �+ • • .
GoodmanNetworks
PLANS PREPARED BY:
NERS ONE
16928 WOODINVILLE-REDMOND RD NE, SUITE 210
WOODINVILLE, WA 98072
PHONE: 425487.1732 FAX:425,4071734
EMAIL: cei@cornerstone—gccom
WWW CORNERSTONE-ENGRCOM
PROJECT INFO:
L ISSUED FOR:
FINAL CD'S
REV:= DATE: —DESCRIPTION:—BY:-CK: 1
FOR FINAL
CD'SJRF
MWO
WISSUE
ISSUE FOR
CLIENT REVIEW
DRA
MWO
DRAWN BY: CHK:=APV.
DRA MWO MWO
C CURRENT ISSUE DATE:
04-13-09
.. LICENSURE:
DRAWING INFORMATION:
DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND AOVISE CON SULTANTS OF ANY
E RRORS AND 01.115SIONS. ALL PREI90US ISSUES OF TKS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE IwowATIOA CONTAINED IN THIS SET OF DGOVLIENTS
15 PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
DRAWING TITLE:
ANTENNA DETAILS
DRAWING NUMBER:
A-4
0
CEI JOB NUMBER: 09.69043
3/4" = 1'-U" 111x17 SCALE: 3/8" = 1'_
man
SWEEP TEST REQUIREMENTS:
AT&T WIRELESS
SEATTLE, WA.
ANTENNA AND TRANSMISSION LINE TEST REQUIREMENTS
REQUIRED EQUIPMENT
(1) WILTRON/ANRITSU SITE MASTER S331A/B/C OR EQUIVALENT
(1) OPEN, SHORT, LOAD
(1) DIN FEMALE TO N TYPE MALE ADAPTER (LOW LOSS)
(1) DIN MALE TO IN TYPE MALE ADAPTER (LOW LOSS)
(2) DIN FEMALE TO DIN FEMALE ADAPTER (LOW LOSS)
(1) PHASE STABLE CABLE
(1) TRUE-RMS MULTI -METER
FREOUENCIES TO BE USED
PCS FREQUENCY BAND 185OMHZ-199OMHZ
TRANSMIT FREQUENCY 1930MHZ-194OMHZ
RECEIVE FREQUENCY 185OMHZ-186OMHZ
TRANSMISSION LINE AND ANTENNA SYSTEM TEST
(1) INSERTION LOSS/CABLE LOSS
(2) ANTENNA/TRANSMISSION LINE DISTANCE TO FAULT (RL)
(3) ANTENNA SYSTEM RETURN LOSS
(4) ANTENNA SYSTEM WITH DUPLEXER/TMA/ANTENNA RETURN LOSS
(5) TRANSMISSION LINE CONTINUITY TEST
INS EM LO
THIS TEST W3LL MEASURE THE CABLE LOSS OF THE TRANSMISSION
LINE AND JUMPERS BETWEEN THE CABINET AND ANTENNA.
TEST FREQUENCIES: F1=1850 F2=1990
1, ENTER THE FREQUENCIES TO BE USED IN F1 AND F2.
2. RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO
DIN (F) CONNECTORS.
4. CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE
THE ANTENNA, OF THE LINE UNDER TEST.
5, CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST.
6. PERFORM MEASUREMENT, THEN DUE STEPS 10 THROUGH 12.
7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER
(.YELLOW)GREEN) TO DIN (F) ADAPTJ R.
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOWIGREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST
9. PERFORM MEASUREMENT, THEN DUE STEP 10 THROUGH 13.
10. ADD THE MAXIMUM PEAK TO THE MINIMUM VALLEY THEN DIVIDE
BY TWO. THIS IS THE CABLE INSERTION LOSS. THIS VALUE SHOULD
NOT BE GREATER THEN -4DB.
11. PEAK MAX (M1) + VALLEY MIN (M2)/2= CABLE INSERTION LOSS.
12. RECORD CALCULATED/MEASURED VALUE ON SWEEP DATA SHEET,
THEN SAVE SWEEP TO A MEMORY LOCATION.
13. REPEAT STEPS 1 THROUGH 12 FOR THE REST OF THE
TRANSMISSION LINES.
ANTENNA SYSTEM RETURN LOSS:
THISTEST MEASURES THE RL OF THE TRANSMISSION LINE
TERMINATING INTO THE ANTENNA WITHOUT THE TMA AND
DUPLEXER.
TEST FREQUENCIES: 171=1850 F2=1990
1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2.
2. RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F)
TO DIN (F) CONNECTORS.
4. CONNECT THE ANTENNA TO THE LINE UNDER TEST,
5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST.
6. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10
THROUGH 13.
7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER
(YELLOW/GREEN) TO DIN (F) ADAPTER.
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOW/GREEN )BEFORE THE CABINET, OF THE LINE UNDER
TEST.
9. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10
THROUGH 13.
10. VERIFY ANTENNA SYSTEM USING 1 5/8" WAVE -GUIDE HAS A RL
LESS THEN -17DB, 20OFT MAX.
11. VERIFY ANTENNA SYSTEM USING 7/8" WAVE -GUIDE HAS A RL
LESS THEN -16DB, 20OFT MAX.
12. FOR SYSTEMS ABOVE 20OFT 1 5/8" RL-15.5DB, 7/8" RL -14DB.
13. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION.
14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE ANTENNA
SYSTEMS.
ANTENNA SYSTEM WITH DUPLEXER AND TMA RETURN LOSS:
PROPOSE[
THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA
NETWORK ON THE TX PATH.
TX TEST FREQUENCIES: F1=1930 F2=1940
PROPOSE[
REPLACEM
1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2
2. RE -CALIBRATE TEST EQUIPMENT.
3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM
JUMPERS.
4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM
JUMPER TO DUPLEXER.
TOP JUMPI
5. CONNECT TEST EQUIPMENT TO TX 1 (YELLOW/RED),
6. PERFORM MEASUREMENT.
7. VERIFY ANTENNA NETWORK USING 1 5/8" WAVE -GUIDE HAS A
DIPLEXOR
RL LESS THEN-15.5DB, 20OFT MAX.
GROUND E
8. VERIFY ANTENNA NETWORK USING 7/8" WAVE -GUIDE HAS A
RL LESS THEN-14,5DB, 200FT MAX.
NEAR ANTI
9. FOR ANTENNA NETWORK ABOVE 20OFT 1 5/8" RL-14DB, 7/8"
RL-12.5DB,
10- RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION.
11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE TX
GROUNDIN
ANTENNA NETWORKS.
ANTENNA SYSTEM W ITH DUPLEXER AND TMA RETURN LOSS:
ANT ENNA/TRANSMiSSION LINE DISTANCE TO LT FAURL L THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA
THIS TEST IS A PERFORMANCEIGATIONAND FAILURE ANALYSIS NETWORK ON THE RX PATH. REMINDER THE TEST EQUIPMENT MAIN COA
TOOL FOR THE ANTENNA, TRANSMISSION LINES AND CONNECTORS. WILL TERMINATE INTO THE TMA ON THE RX PATH. CABLE (TY
TEST FREQUENCIES: F1=1850 F2=1990 RX TEST FREQUENCIES: F1=1850 F2=1860
1, ENTER THE FREQUENCIES TO BE USED IN F1 AND F2.
2, RE -CALIBRATE TEST EQUIPMENT.
3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS
TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO
DIN (F) CONNECTORS.
4. CONNECT THE ANTENNA TO THE LINE UNDER TEST.
5, CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER
(YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST.
6. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10
THROUGH 13,
7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER
(YELLOW/GREEN) TO DIN (F) ADAPTER.
8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER
(YELLOW/GREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST.
9. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10
THROUGH 13.
10. VERIFY EACH DIN CONNECTOR HAS A RL LESS THEN -32DB, N TYPE
-28DB.
11. VERIFY THE TRANSMISSION LINE HAS A RL LESS THEN -45DB,
12, VERIFY THE ANTENNA HAS A RL LESS THEN -17DB.
13, RECORD PASS/FAIL ON SWEEP DATA SHEET, THEN SAVE SWEEP
TO A MEMORY LOCATION,
14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE ANTENNA'S
AND TRANSMISSION LINES.
1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2
GROUND 13
2. RE -CALIBRATE TEST EQUIPMENT.
NEAR EQU
3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM
JUMPERS.
4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM
JUMPER TO DUPLEXER.
5. CONNECT TEST EQUIPMENT TO RX 1 (YELLOW/GREEN),
6. PERFORM MEASUREMENT.
DIPLEXOR
7. VERIFY ANTENNA NETWORK USING 1 5/8" WAVE -GUIDE HAS A
RL LESS THEN-16.5DB, 20OFT MAX.
8. VERIFY ANTENNA NETWORK USING 7/8" WAVE -GUIDE HAS A
BOTTOM J
RL LESS THEN-15.5DB, 20OFT MAX.
9. FOR ANTENNA NETWORK ABOVE 20OFT 1 5/8" RL -14DB, 718"
RL-13 ' 5DB.
10. RECOD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE
SWEEP TO A MEMORY LOCATION,
11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE RX
ANTENNA NETWORKS.
TRANSMISSION LINE CONTINUITY TEST:
THIS TEST WILL VERIFY THE CONTINUITY OF THE RX PATH
BETWEEN THE BTS AND THE TMA FOR THE 15 VDC
NETWORK.
1, CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE
THE TMA, OF THE LINE UNDER TEST.
2. CONNECT MULTI -METER TO LAST JUMPER BEFORE THE BTS, RX 1
(YELLOW/GREEN). PLACE THE BLACK LEAD ON THE OUTER PART
OF THE CONNECTOR AND THE RED LEAD ON THE CENTER PIN
OF THE CONNECTOR
3. VERIFY THE METER READS A SHORT.
4. REMOVE SHORT AND VERIFY METER READS OPEN.
5. RECORD PASS/FAIL ON SWEEP DATA SHEET.
6.. RECONNECT JUMPERS TO TMA AND BTS.
7. REPEAT STEPS 1 THROUGH 6 FOR THE REMAINING RECEIVE
PATHS.
r_l"11JAZIM,
.;ABLE MARKING TAGS
TO PROVIDE ADDITIONAL IDENTIFICATION EACH RF CABLE SHALL
BE IDENTIFIED WITH A METAL TAG MADE OF STAINLESS STEEL
OR BRASS AND STAMPED AS SHOWN. THE ID MARKING
LOCATIONS SHOULD BE AS PER "CABLE MARKING LOCATIONS
TABLE". THE TAG SHOULD BE ATTACHED WITH CORROSION
PROOF WIRE AROUND THE CABLE.
THE FOLLOWING ARE 3 DIFFERENT FORMATS TO BE USED FOR THE
BRASS TAGS.
1A 1A 1A
(D(D
G9U9
FORMAT A FORMAT B FORMAT C
DIAGRAM OF BRASS TAG FORMATS
FORMAT A IS USED WHEN THERE IS ONLY ONE TECHNOLOGY BEING
CARRIED ON A CABLE. FORMAT B IS USED WHEN TWO
TECHNOLOGIES HAVE BEEN DIPLEXED ONTO ONE CABLE AND WILL
BE BROKEN OUT THROUGH A DIPLEXOR AT THE TOP OF THE
TOWER. FORMAT C IS USED WHEN TWO TECHNOLOGIES HAVE BEEN
QUADRAPLEXED ONTO ONE CABLE FOR ANTENNA PORT SHARING
AT THE TOP OF THE TOWER
THE FIRST NUMBER DESIGNATES THE ANTENNA POSITION, THE
SECOND CHARACTER DESIGNATES THE PORT ON THE ANTENNA,
THE THIRD CHARACTER DESIGNATES THE TECHNOLOGY TYPE, AND
THE LAST NUMBER DESIGNATES THE FREQUENCY BAND OF THE
OSED RET'S
TECHNOLOGY.
B1
SECTOR 1 SECTOR 2
QSEDTMA'
RF CABLES A2 RF CABLES B2
THRU B6 AS
THRU A6 AS
REO'D REO'D
Al � Cl
SECTOR 3
:R CABLE
RF CABLES C2
THRU C6 AS
REO'D
NOTE:
SECTOR ORIENTATIOWAZIMUTH WILL
NEAR ANTENNAS
VARY FROM REGION TO REGION AND IS
IAR
SITE SPECIFIC REFER TO RF REPORT FOR
EACH SPECIFIC SITE TO DETERMINE THE
SECTOR ORIENTATION
IG KIT
VIAL
P)
3AR
IIPMENT
ALL RF CABLE SHALL BE MARKED AS PER CABLE MARKING
I OCATIONS TABLE BELOW:
CABLE MARKING LOCATIONS
NO- ITAG
LOCATIONS
1
X
END OF THE MAIN COAX RUN WHERE THE COAXIAL
CABLE AND JUMPER TO THE ANTENNA ARE
CONNECTED.
2.
X
CABLE ENTRY PORT ON THE INTERIOR OF THE
SHELTER (AS APPLICABLE).
3
X
END OF JUMPER AT BTS CABINET
CABLE COLOR MARKING
IN ADDITION TO THE IMPLEMENTATION OF BRASS TAGS,
CONTRACTORS SHALL USE ONE BAND OF COLOR TAPE PER
CABLE FOR SECTOR DESIGNATION LABELING.
THE COLORS SHALL BE AS FOLLOWS:
IUMPER CABLE SECTOR A: RED
SECTOR B: BLUE
SECTOR C: GREEN
THE SECTOR DESIGNATIONS SHALL BE MARKED AS DESCRIBED
ON THE CURRENT RF DATA SHEET (RFDS) AT TIME OF
INSTALLATION. RF DATA SHEET IS TO REMAIN POSTED AT
EVERY SITE
COAX BOOT SPECIFICATION
ENTRY BOOTS TO SEAL COAX WITHIN 6" CONDUITS SHALL BE:
ROXTEC H SEAL
H3-150/3X(28-54)/20 SEE COAX CONDUIT EXIT SEAL DETAIL
(WHEN APPLICABLE)
CONTRACTOR SHALL USE THE ABOVE PRODUCTS OR
APPROVED EQUAL
W`� � at&t
Your world. Delivered.
PROJECT CONSULTANTS:
GoodmanNetworks
•II.•r.0
PLANS PREPARED BY:
�CQPl NEFRsirONE
�+ ■.MOINEENINo.INc.
16928 WOODINVILLE-REDMOND RD NE. SUITE 210
WOODINVILLE, WA 98072
PHONE: 425.467.1732 FAX:425487.1734
EMAIL: ce i@cornersto ne-gr. cam
W WW.CORNERSTONE-ENGR COM
, PROJECT INFO:
L ISSUED FOR:
FINAL CDIS
REV:= DATE: =DESCRIPTION: -BY -CK:�
p
04-13-09
ISSUE FOR FINAL
CD'S
JRF
MWO
A
03-26-09
ISSUE FOR
CLIENT REVIEW
DRA
MWO
DRAWN BY: CHK.: -APV --
DRA &w."O M%NO
CURRENT ISSUE DATE:
04-13-09
UCENSURE1
� 1 ■
1
! ExPIRES D214er1D
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION.
THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS
IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE
OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS
STRICTLY PROHIBITED
:DRAWING TITLE:
ANTENNA SWEEP TEST &
COAX COLOR CODING
:DRAWING NUMBER:
A-5 0
CEI JOB NUMBER: 09.69043