09-102141CfTY OF A. Federal July 10, 2009 Becky Todd Pacific Telecom Services 568 1" Avenue, Suite 650 Seattle, WA 98104 FILE CITY HALL 33325 8th Avenue South Mailing Address: PO Box 9718 Way Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com RE: File #09-102141-00-UP; USE PROCESS I DIRECTOR'S APPROVAL AT&T Tammy Lane/WA415, 34301 9te Avenue South, Federal Way Dear Ms. Todd: The City's Planning Division has completed an administrative land use review of the proposed Personal Wireless Service Facility (PWSF) antenna replacement on an existing American Tower Corp. owned monopole on Parcel #202104-9157 at the address referenced above. The site is owned by the United States Postal Service, and the tower is owned by American Tower Corp. The Process I application was submitted and determined to be complete on June 10, 2009. Pursuant to Federal Way Revised Code (FWRC) 19.55, "Process I — Director's Approval," your proposal is found to be consistent with the provisions of Chapter 19.255 — Personal Wireless Service Facilities. Your Process I proposal is hereby approved. The Process I land use approval is supported by the following statement of facts: 1. Zoning & Land Use —The zoning designation for the subject property is Office Park (OP). PWSFs are permitted in the OP zone pursuant to the zoning chart found in FWRC 19.215.100. Review Process — According to submitted materials, the applicant proposes to replace three existing antennas with three new models, replace six existing Tower Mounted Amplifiers (TMA) , add six new model TMAs, and add three remote electrical tilts (RETs). The replacement of three antennas with new models with a change in dimensions is not exempt from FWRC 19.255.010(3)(f) "routine maintenance or repair" and requires a Process I Master Land Use Application. Please note the project description states that this facility is located in the City right-of-way. After conducting a review of this project it is clear this PWSF is not located in a right-of-way and was reviewed as such. Cumulative Effects — The City must consider the cumulative visual effects of PWSFs mounted on existing structures and/or located on a given permitted site in determining whether additional permits may be granted so as to not adversely affect the visual character of the City. Currently, the antennas are long and narrow (104"xl 1"x5") and are painted a non -reflective color to match the PSE pole. The proposed antennas are smaller but wider (52"x22"xl 1") and will be painted the same color as the existing antenna. As shown in the plans and elevations, the size change is not a substantial increase, and the proposed PWSF will not adversely affect the visual character of the City. 4. State Environmental Policy Act (SEPA) — The project is exempt from SEPA review as it meets the exemptions of WAC 197-11-800(25). 'Ws. Todd July 10, 2009 Page 2 5. Additional Permits —No building permits are required for this proposal. However, an electrical permit will be required. Please contact a Development Specialist at 253-835-2607 if you have questions regarding the electrical permit application process. 6. Process I Thresholds —The proposed improvements do not reduce required parking, landscaping, buffering, open space, or public areas; do not change the location of utilities or easements; and create no impacts to sensitive areas or significant trees. CLOSING This decision shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this site. Final construction drawings will be reviewed for compliance with specific regulations and other applicable City requirements. This Process I approval does not constitute approval of an electrical permit. The effective date of this decision is July 13, 2009, or three days from the date of this letter. Pursuant to FWRC 19.55.050, any person who received notice of this administrative decision may appeal the decision to the Federal Way Hearing Examiner by July 27, 2009. Any appeal must be in the form of a letter delivered to the Department of Community Development Services with the established fee. The appeal letter must contain a clear reference to the matter being appealed and a statement of the alleged errors in the Director's decision, including the identification of specific findings and conclusions made by the Director disputed by the person filing the appeal. No work on the proposal can commence until the end of the appeal period. If an electrical permit is required, you may not commence work until you have been issued the appropriate permit(s). This Process I approval is valid for one year from the effective date of this decision. If no further action is taken within one year, this decision will expire. A one-time, 180-day extension may be granted only if a written request is submitted to the City's Department of Community Development Services (address above) at least 30 days prior to the expiration of the decision. If you have any questions regarding this decision, please contact Becky Chapin, Planning Intern, at 253- 835-2641 or Rebecca.Chapin@cityoffederalway.com. Sincerely, Greg Fewins, Director Community Development Services enc: Approved Site Plan c: Rebecca Chapin, Planning Intern 09-102141 Doc I D. 50581 RECEIVED Project Name: WA415 Tammy Lane/ATC Location: 34301 91h Ave S. JUN 10 2009 PROJECT DESCRIPTION: CITY OF FEDERAL WAY CDS AT&T is proposing to upgrade an existing wireless facility that is co -located on an existing ATC-owned monopole in a commercial area. The site is a multi -carrier pole, and AT&T leases space for its ground equipment on the same property upon which the tower is located. The ground equipment is enclosed in a shelter. The proposal consists of the following upgrades: • Swap existing antenna (104"x11"x5") for new antenna (52"x22"x11"); see A-2 for elevations • Swap 6 of the existing TMA for new models and add 6 new model TMA; see A-4.5, A-4.6 for specifications • Add 3 remote electrical tilts (RETs); the RET allows the angle of the antenna to be adjusted remotely and increases site maintenance efficiency; see A- 4.1, A.4-4 for specifications COMPLIANCE WITH WIRELESS FACILITY DESIGN STANDARDS: This facility is an existing facility located in the City right-of-way. While there is no increase in the height of the structure or the number of antennas, the dimensions of the antenna are changing and thus the proposal was determined to be outside of the 19.255.010(f) exemptions. With the facility upgrade using the new antenna, 52"x22"x11", the facility will remain in compliance with the applicable design standards for facilities located in the right-of-way. The site as it exists exceeds the dimensions for a microcell or minor facility, and would have received discretionary review under Process I/Director Approval. While the proposed antennas do exceed the threshold for microcell dimensions, they do not represent a substantial size increase from the existing approved antennas. The existing antennas are long and narrow (103"x11"), and the proposed antennas are half as long and wider (52"x22"). The new panels will not have significant visual impact on the silhouette of the facility as a whole. The facility is a multi -carrier monopole with three existing carriers, and AT&T's array is flush -mounted and therefore closer to the pole than the second carrier; even with the wider antennas, the proportions of the arrays will stay consistent with the existing look. The proposed antennas are within the limits for maximum antenna height under the development standards for building or structure mounted PWSFs in 19.255.020(1)(b), which limits panel antennas to 15 feet in height above the existing structure. The proposed antennas will not add any height to the structure. There will be no increase in the number of antennas, and the RETs and TMA are installed on the backs of the antenna panels and will not impact the silhouette of the facility. MASTER LAND UR APPLICATION DXrARTmxNT OF COHNI(INITY 1309LOPMENT. SERVICZS ITT OP RECEIVED 97.1 S. Pederal Way WA,010.634118 z,ed Oral Way JUN 10 2009 -www cftypffederalLyg,co'm CITY OF FEDERAL WAY : -- CDS &PLICATTONNO(S) z0zV/ Date roject-Name, 2. WN-k�51 pt. vt� ro.perrty- Address/Loenfion 61 gAl AMC, arcel Numbers) MHA &-e-4 4-OW to HHA at:. aii OW-Ak"L,-q. j)Kt*,sS W, Type of Permit Required Annexaflon Binding Site Plan Boundary Line Adjustment. Comp Plan/Rezone Ladd $tidace Modification Lot Line Elimination Pkeapplidation Conference �~Process I (Dijwor-s Approval) Pr000s$. -11 (Site Plan Review) Process HY (Projett Approval) Procoss IV (.fleoring'ExomiiiersDecisibi!) Process V (Qoasi-judicial RCZDne) procog VI SBPA-wz?rojert GBPA, 041� —ShQreli*i Vnianpe/CQndlOonal Use Short Bubdivhion Sub.dkVIS101T. Variance: Commercial/Regidendal- Required Wormation -ZoningDesignatlon Comprehensive Plan DesigdaflOn Value of Existing ljnprovqrn6nts 'S i&M. e'Q'-!,Valhd of Proposed improvements kiternadonal Building -Code: (lBQ: tkn V ysa u" &1-0 c c u P a ri qy- Typ a Typo A.P. H watit Mite Poul '-y-sS"r Add 9! ies tkAv* S, 40 atylswe: stotl IV. A Zip; 41 ' %VOL+ MP Phone. Z6t# AY4" J� Ageat (w diffa6xtthaxi Applioant) -Natwi. Address: 1P. Phone,. Signature; Owner: Name: A4dress,,. fo City/State:. -04 4 zip- 404-0/ Fhone- -small: signature: "Sow c al q1.!OLIn4.1003 AU&st 11,2004 page I r I f kAHan-(j1w0U0wr- Land OAp -f --4~eA?5.f lwc r at&t Your world. Delivered. RTC BUILDING 3.16221 NE 72ND WAY REDMOND, WA 98052 VICINITY MAP SITE LOCATION 1\ reavrw� �.: DRIVING DIRECTIONS GoodmanNetworks Network Knowledge... Delivered TAM MY LANE 34301 9tH AVE S FEDERAL WAY, WA 98003 KING COUNTY WA415 AMERICAN TOWER CORP. SITE # 91531 GENERAL LOCATION MAP SITE LOCATION T N A _ J= 6 S 31nh PI . •: S 31Brh pI .. FROM AT&T MOBILITY IN REDMOND: HEADING WEST ON SR-520 TO 1-405 SOUTH, TAKE 1-405 SOUTH TO 1-5 AND HEAD SOUTH ON 1-5. TAKE THE HWY 509 EXIT WESTBOUND, TO INTERSECTION WITH 1ST WAY SOUTH. AT 1ST WAY SOUTH, TAKE A LEFT AND HEAD SOUTH. CONTINUE TO INTERSECTION WITH S. 336TH STREET. TURN LEFT, HEADING EAST TO INTERSECTION WITH 4TH AVE S. CONTINUE UNTIL DRIVEWAY FOR US MAIL IS ON RIGHT (WEST SIDE). TURN IN AND SITE IS ON NORTH SIDE OF THE PROPERTY APPROVAL/SIGN OFF OF CONSTRUCTION DRAWINGS CONSULTANT GROUP SIGN OFF DATE SIGNATURE AT&T SIGN OFF DATE SIGNATURE CONSTRUCTION COORDINATOR RF ENGINEER LANDLORD'S REPRESENTATIVE INTERCONNECT PROJECT MANAGER SITE ACQUISITION ZONING OPERATIONS COMPLIANCE CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED PROJECT INFORMATION APPLICANT: PROPERTY OWNER: AT&T MOBILITY CORPORATION AMERICAN TOWER CORP. 16221 NE 72nd WAY, RTC 3 116 HUNTINGTON AVE, 11th FLOOR REDMOND, WA 98052 BOSTON, MA 02116 PHONE: (949) 442-6400 x101 PROJECT ENGINEER: CORNERSTONE ENGINEERING, INC. PROJECT CONSULTANTS: 16928 WOODINVILLE-REDMOND RD N.E. SUITE 210 GOODMAN NETWORKS WOODINVILLE, WA 98072 8815 122ND AVE. NE MARK W OLSON, P.E. KIRKLAND, WA 98033 PH: (425) 487-1732 FAX: (425) 487-1734 PROJECT MANAGER: CONTACT: ERIK ZITTLEMAN ezittl eman @ good mannetworks. corn SITE AQUISITION CONTACT: REYNATAFEYTON rfeyton@ptswa.com ZONING AGENT: CODE fNFORMATIM. CONTACT: SUNNY YIM ZONING CLASSIFICATION: C-COMMERCIAL syim@ptsw&oom BUILDING CODE: IBC2006 CONSTRUC"I'lON MANAGER: CONSTRUCTION TYPE: TELECOMMUNICATIONS CONTACT: JIM BELLAR OCCUPANCY: UNOCCUPIED GROUP "U" jbellar@goodmannetworks.com JURISDICTION: FEDERAL WAY PARCEL NUMBER: PROPOSED BUILDING USE: TELECOMM 2021049157 SITE LOCATION: BASED ON NAP-931 AREA OF PARCEL: LATITUDE: 47` 17' 46.9" N (47.29636) 2.245.518 SQ. FT (51,55 ACRES) LONGITUDE: 122* 19' 34.9" W (122.32636) TOP OF STRUCTURE: 120'-0" (MONOPOLE) NEW IMPERVIOUS AREA: BASE OF STRUCTURE: 0'-0" AMSL (ASSUMED) 0 SO. FT. PROJECTAREA: 0 SQ. FT. GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED, (NON ASSIGNEDTECH PARKING) 2. TRAFFIC IS UNAFFECTED. 3. NO SIGNAGE IS PROPOSED, PROJECT DESCRIPTION: THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY. CONSISTING OF THE REMOVAL AND REPLACEMENT OF (3) PANEL ANTENNAS AND THE ADDITION OF (3) RET'S, REMOVAL AND REPLACEMENT OF (6) MHA'S ALONG WITH THE ADDITION OF (6) NEW MHNS TO AN EXISTING 120-FOOT STEEL MONOPOLE. PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO AT&T WIRELESS, LLC. SERVICES IS STRICTLY PROHIBITED. DRAWING INDEX DWG. N0. DESCRIPTION T-1 TITLE SHEET G-1 GENERAL NOTES A-1 ENLARGED SITEPLAN A-2 EXISTING & PROPOSED WEST ELEVATIONS A-3 PROPOSED AND EXISTING ANTENNA PLANS A-4 ANTENNA DETAILS A-6 ANTENNA SWEEP TEST & COAX COLOR CODING I LEGAL DESCRIPTION I FOR OF N 1/2 DAF: BEG CENTER OF SEC; TH N 01-16-46 E ALG N-S C/L 360.82 FT TH N 88-46-14 W 330 FT TH S 01-16-46 W 179.36FTTONLNOFS181.5FTOFSDN1/2THN88-46-40 W 220 FT TH S 01-16-46 W 181.5 FT TO ENV 1/4 LN SD SEC; TH N 88-46-40 W 521.96 FT TO A PT S 88-46-40 E 1544,35 FT FIR W 1/4 CDR SD SEC TH N 01-10-59 E 712.14 FT TH N 53-40-00 W 543.88 FT TH N 36-20-00 E 310 FT; TH ON CURVE TO LEFT RAD 1250 FT THROUGH C/A 18-47-35 ARC DIST OF 410 FT TH S 72-27-35 E 789.85 FT TH S 35-00-00 E 134.66 FT TO S LN OF NE 1/4 OF NW 1/4 TH ON SD S LN & S LN OF NW 1/4 OF NE 1/4 S 88-45-47 E 795.73 FT TAP ON 1130 FT RAID CURVE WHOSE CENTER PT BEARS S 84-52-30 E TH SLY ALG SD CURVE THROUGH C/A 09-57-30 ARC DIST OF 196.40 FT TH S O4-50-00 E 460 FT TAP OF 810 FT RADIUS CURVE TO RGT TH ON SD CURVE THROUGH C/A 30-00-00 ARC DIST OF 424.12.FT TH S 25-10-00 W 271.12 F7 TO EIW CIL SD on k � D 88.46.40 W 348,35 FT TO CENTER SD 0 V C J U N 10 2009 CITY OF FEDERAL W 0 at&t Your world. Delivered. ~ PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: �GPRrJI��['�rYe ■r� aHal.raw�wo, Ixe. 16928 WOODINVILLE-REDMOND RD NE. SUITE 210 WOOD INVILLE, WA 9BO72 PHONE: 425487.1732 FAX: 4254671734 EMAIL: cei(Zrners0necng,. W W W CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR: FINAL CUS REV:= DATE: = DESCRIPTION: =BY:= CK:� 0 0 04-13-09 ISSUE FOR FINAL JRF MWO AL3-26-09 ISSUE FOR CLIENT REVIEW DRA MWO L DRAWN BY: CHK.: —Arv_ ORA MWO I MWO C CURRENT ISSUEDATE. 04-13-09 r LICENSURE: W 1V :DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSION& ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. = DRAWING TITLE: TITLE SHEET _DRAWING NUMBER: T-1 0 CEI JOB NUMBER: 09.69D43 GENERAL NOTES: 1 DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS TAKE PRECEDENCE, THIS SET OF DOCULIEWS IS INTENDED TO BE USEF) FOR OIAGRAL1=MPURPOSESONLY, UNLESS NOTED OTHER4VtSE. TKE43F _RAL CONTRAC7OR5 SCOPE OF L4ORIC SNAIL INCLUDE FURNISHING ALL MATERIALS. EQUiPME NT, LASOR AND ANY REOUI RELiENTS DEEI.IEO NECESSARY TO COMPLETE PROJECT AS, DESCRIBED IN THE PAAWMaS AND OWNER'S PROJECT MANUAL 2 PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT CONTRACTORS SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTIOWCONTRACTOOCUMENIS TO VERIFY FIELD CONDITIONSAND CONFGRIA THAT THE PROJECT WILL BE ACCOMPU$HED AS SHOWN PRIOR TO PROLE BOINO VNRM CONSTRUCTION- ANY ERRORS. OMISSIONS. OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING 3 THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCLII.IENTS THE COMPLETE. SCOPE OF WORK CONTRACTORS BIDDING THE JOB ARE NEVERTMELESSCAUTKINED THAT MINOR O1,IIS'IONS DR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT E7(CUSE SAID COHTRAOTOR FROI.4 COMPLETING THE PRGJEC7 AND R.SPROVEIAE NTS IN ACCORDANCE WITH THE 1NTENT OF THESE DOCUMENT$- THE BIDDER SHALL BEAR THE RESPONSBILRY OF NOTIFYING IIN WRITING) THE ARCWfEe;ENCINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK UNLESS DIRECTED OTHERWISE A THE CONTRACTOR SHALL SUPERVISE AND OLRECT THE PROJECT DESCMED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS- METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT, 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'SNENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE 6 ALL WORKPFRFORMED ON THE PROJECT AND MATERLALSINSTALLED SHALLSE IN STRICT ACCORDANCE MTN ALL APPLICABLE CODES, REGULATIONS. AJOORDINANCES. CONTRAGTORSHALL GIVE ALL NOTICES AND COMPLY VWK ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK 7. GENERAL CONTRACTOR SHALL PROVIDE. AT THE PROJECTSITE, A FULL SET OF CONSTRUCTION DOCUMENTS UPDATED 15TDI THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT. THIS SET IS A VALID CONTRACT DOCUMENT ONLY IF THE TITLE SHEET IS STAMPED "FOR CONSTRUCTION' AND EACH SUCCESSIVE SHEET BEARS THE ARCHITECT'S SIGNED WET STAMP. 8, THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE 9. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE, 10. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION, 11, CONTRACTORSNALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENM EASEMENTS, PAVING. CURBING, ETC. DURING CONSTRUCTION, UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. 12. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE, 13 THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 14 THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS 15 THE CONTRACTOR SHALL PROVIDE AT&T WIRELESS, LLC. PROPER INSURANCE CERTIFICATES NAMING AT&T WIRELESS, LLC. AS ADDITIONAL INSURED, AND AT&T WIRELESS, LLC, PROOF OF LICENSE(S) AND PE & PD INSURANCE. 16 CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND COORDINATING ALL INSPECTIONS. IT CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION DIAL 611 1& CONTRACTOR TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO AT&T WIRELESS, LLC ALONG WITH REDLINED CONSTRUCTION SET. 19. CONTRACTOR TO DOCUM EN7 ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THEAPPROVEO CONSTRUCTION SET AND SUBMITTING THE REDLINED SET TO AT&T WIRELESS, LLC. UPON COMPLETION. 20. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK 21, GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED, CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTION(S)TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 22. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT. MUST BE APPROVED BY AT&T CONSTRUCTION MANAGER 23. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 24. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES ORTRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNERIPABR ICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNAtCOfXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTO SIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTO SIMULATIONS SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR. CONSTRUCTION COORDINATOR. AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. GENERAL NOTES CON I t RE 25 fN THE CASE OF ROOFTOP SOLUTK]PfS FOR EIXNPMENT AND'OR ANTENNA FRA}.TES YHE ANCHORING TO A CONCRETE ROOF SLAB IS RE GUTAED. CONTRACTORS SHALL CONFIRM (PRIOR TO SUBTAITYI NG BID) WITH CONSULTING CONSTRUCTION COOROMA70R AND ARCHITECT THE PRESENCE OF POSSTTENMN TENDONS %MTHIN THE ROOF SLAB -RESULTING FROM AN UNDOGVMENTED DESIGN CHANGE 1H THE EXISTING BVILDING'AS-BUILT DRAWING $Es'' HAVING INDICATED AN ORIOWAL DESIGN SOLUTION OF REINFORCED CONCRETE W7 EMBEDDED STEEL AEBAR. IN THE EVERT POST TENSLGN SLAB SOLUTION ISPRESENT-CONTRACTOR SHALL INCLUDE PRGVISIGNS FOR X-RAY PROGEOVRES (INCLUDED IN SLDI FOR ALL PEHETRATION AREAS 74-0 RE ANCHORING OCCURS 26 GENERAL& SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE MY" (WHERE APPLiCA8LET PLASTIC ZIP 1I85 SHALL NOT BE PERMITTED FOR USE ON AT&T PROJECTS. RECOMMENDED MANUFACTURE SHALL SE: PANDUITCORP- METAL LOCKING TI£51.1(JDEL NO. ML74S�,P UNDER SERIFS41A (OR EQUAL) PANDUIT PRODUCT DISTRIBUTED BY TRIARC OF TACOMA. WA DESIGN CRITERIA: 1. THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE 2006 WITH WASHINGTON STATE BUILDING CODE AMENDMENTS (20061BC) Z DESIGN LOADS:. DESIGN DATA FOR KING COUNTY. WA: -ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) -BASIC WIND SPEED 85 MPH (3 SEC GUST) -WIND EXPOSURE B CONCRETE NOTES: I. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318 2 CONCRETE SHALL BE MIXED, PROPORTIONED. CONVEYED AND PLACED IN ACCORDANCE WITH CHAPTER 19 OF THE 20061BC. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS TYPE OF CONSTRUCTION 26 DAY STRENGTHS W/C MINIMUM CEMENT (rc) RATIO CONTENT A SLABS ON GRADE PER CUBIC YARD TOPPING SLABS CONCRETE PIERS 2.400 PSI .45 5112 SACKS B. ALL STRUCTURAL CONCRETE 4,000 PSI `_ .45 6 1/2 SACKS EXCEPT WALLS C. CONCRETE WALLS 4.000 PSI '_ .45 6 V2 SACKS CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O. 3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT- 4 ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR{HTRAININOAGEHTCONFORMINC TO RS'ILI C200, C494, C618, C9&4AND C10L7. TOTAL AIR CONTEN7SHALL BE IN ACCORDANCE WITH TABLE 1904 2 1 OF THE 20061BC 5 REI NFORGNO STEEL SHALL CONFORM TOASTId A615 NINCLUDING SUPPLEMENT $1I. GRADE 60, Iy�00,006 PSI EXCEPTIONS. ANY BARS SPECIFICALLY SO NOTED OH THE CRAWINGS SHALL B£ GRADE 40, lr40.000 PSI GRADE 00 REINFORCWG BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A708 REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A W.S D14 ARE SUBMITTED 6, RE WFORCING S TIE EL SHALL BE DETAILED (INCLUDING NOOKS AND BENDS) IN ACCOR DANCE VATH AC &15 AND $36. LAP ALL CONTINUOUS REINFORC£IAENT AT LEAST 30 GAR DIAMETERS OR A MNNIMUM OF Z-O". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERSORA MINIMUM OF 2'-O". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF B' AT SIDES AND ENDS. 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 B. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy=60.000 PSI. 9 NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE CONSULTANT, 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: • FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 3" • FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) 2" (#5 BARS OR SMALLER) 1 1/2" - SLABS AND WALLS (INTERIOR FACE) 3/4 11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS 12. ANCHOR BOLTS TO CONFORM TO ASTM A307 13 NONSHRIHK GROV7 SHALL BE FUAN1SHEO BY AN APPROVED MANUFACTMER AND SHALL BE 1.11)LEO AND PLACED IN STRICT ACCORDANCE WITH THE UANUFACTURER'S PUBLISHED RECOMMEWAX4115 GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3.000 PSI MINIMUM) 14. ALL EXPANSION ANCHORS TO BE HILTI BRAND ADHESIVE ANCHORS REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER STRUCTURAL STEEL NOTES: 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BMTING, EXPANSION BOLTS. AND THREADED EXPANSION ANCMOF75) SHALL BE BASEOON THE A I:S I. "SPECIFICATION FOR THE DE510N. FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR &HLDIWGS' LATEST EDITION x(P$RVISION SHALL BE IN ACCORDANCE WITH 'AM ISC CHAPTER 22. BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE CONSULTANT THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A WIDE FLANGE SHAPE ASTMA-99Z Fy 50 KSI R OTHER SHAPE, PLATES AND ROD ASTM A36, Fy 36 KSI C PIPE COLUMNS ASTM A53. Fy 35 KSI D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI E- ANCHOR BOLTS ASTM A307 F. CONNECTION BOLTS ASTM A325 4 ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER A123/A123M-00 5 ALL WELDING SHALL BE W CONFORMANCE 1L•ITH A I S I AND AWS STANDARDS AND SHALL BE PERFORFAEO BY Yf.A R.O. CE RTDIED WELDERS USINO E70 XX ELECTRODES. ONLY PRECKJALBrKiD;MOE (AS DEFINED BY AWS) SHALL BE USED. VELDING OF GRADE W REINFORCING BARS IIF REQUIREOI SHALL BE PER RNWED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS IF REQUIRED) SHALL BE PERFORATED USING E70 XX ELECTRODES IVELOING WITHIN 4' OF COLD BENDS iH REINF ORGNG STEEL IS NOT PERLITRE D. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS 6, COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE. SIZE, AND GAGE SHOWN ON7HE PLANS PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE AI.S.I. 'SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS" 7- BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (314" DIA )AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE & NONSTRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/9" DIA ASTM A307 BOLTS UNLESS NOTED OTHERWISE 9. ALL STEEL WOR K SHALL BE PAINTED IN ACCORDANCE WITH THE DESIGN & CONSTRLICTIDIN SPECIFICATION AND IN ACCORDANCE WITH ASTM A36 UNLESS NOTED OTHERWISE. 1Q ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE 11. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL TOWER/POLE NOTES: 1. VERIFICATION THAT THE PROPOSED TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA LOADING IS TO BE DONE BY OTHERS Z PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL AND FUTURE ANTENNAS ANTENNA COAX CABLES ARE TO BE SUPPORTED AND RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS ABBREVIATED ROOF TOP SAFETY PROCEDURES (WHEN APPLICABLE): (AS PER "ACCIDENT PREVENTION PROGRAM' -BY PERMISSION OF WREN CONSTRUCTION, INC.-03/01199) FALL PROTECTION METHODS AND EQUIPMENT ROOF TOP INSTALLATIONS 1. FOR WORK IS BEING PERFORMED WITHIN 25- OF AN UNPROTECTED ROOF EDGE. THE CONSTRUCTION SUPEAVI50R SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS 2 SAFETY K40NITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I E. BACKING UP TOWARD A ROOF EDGE, ETC) OR UNSAFE ACTIVITIES THE SAFETY MONITOR MUST BE ON THE SAME ROOF AND WITHIN VISUALAND VERBAL DISTANCE OF THE CONSTRUCTION WORKERS 3. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN V OR LESS OF AN UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE 4. SAFETY LINE SHALL BE MINIMUM h" DIAMETER NYLON. WITH A NOMINAL TENSILE STRENGTH OF 5400 LBS 5. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE STRUCTURE 6. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE OF ROOF, BUT NOT BEYOND 7. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS 8. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES. INCLUDING: INSPECTION OF CONSTRUCTION AREA FOR HAZARDS USE OF AN INSPECTION CHECKLIST INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS REPORTING AND DOCUMENTING ANY HAZARDS REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN RECEIVING AN UNBIASED RENEW OF ONE'S OWN WORK AREA BY ANOTHER COWORKER SAFETY REPRESENTATIVE REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NATIONAL ASSOCIATION OF TOWER ERECTORS 2000 PUBLICATION REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY T05YFSLEAECTORS. EQUIPMENT INSTALLERS, AND TOWER.ROOF TOP CONTRACTORSSUSCONTRACTORS 29 OFF; sBn'.500 - SCOPE, APPLICATION. AND WWI TIONS 29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION 19 CFR 1926.502 -FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES YMBOLS AND ABBREVIATIONS A/C AIR CONDITIONING LBS POUNDS AGL ABOVE FINISH GRADE MAX MAXIMUM APPROX APPROXIMATELY MECH MECHANICAL MTL METAL BLDG BUILDING MFR MANUFACTURE ELK BLOCKING MGR MANAGER MIN MINIMUM CLG CEILING MISC MISCELLANEOUS CUR CLEAR CONC CONCRETE NA NOT APPLICABLE CONST CONSTRUCTION NIC NOT IN CONTRACT CONT CONTINUOUS NTS NOT TO SCALE DBL DOUBLE OC ON CENTER DIA DIAMETER OD OUTSIDE DIAMETER DIAG DIAGONAL DIN DOWN PLYWD PLYWOOD DIET DETAIL PROJ PROJECT DWG DRAWING PROP PROPERTY PT PRESSURE TREATED EA EACH REG REQUIRED ELEV ELEVATION RM ROOM ELEC ELECTRICAL RO ROUGH OPENING EQ EQUAL EQUIP EQUIPMENT SHT SHEET EXT EXTERIOR SIM SIMILAR SPEC SPECIFICATION RN FINISH SF SQUARE FOOT FLUOR FLOURESCENT SS STAINLESS STEEL FUR FLOOR STL STEEL FT FOOT STRUCT STRUCTURAL STD STUD GA GAUGE SUSP SUSPENDED GALV GALVANIZED GC GENERALCONTRACTOR THRU THROUGH GRND GROUND TIMING TINNED GYP BD GYPSUM WALL BOARD TYP TYPICAL HORZ HORIZONTAL UNO UNLESSNOTED HR HOUR OTHERWISE HT HEIGHT HVAC HEATING VERT VERTICAL VENTILATION VIF VERIFY IN FIELD AIR CONDITIONING W/ WITH ID INSIDE DIAMETER W/O WITHOUT IN INCH WP WATER PROOF INFO INFORMATION INSUL INSULATION TNT INTERIOR IBC INTERNATIONAL BUILDING CODE - T T- TELEPHONE -p P- POWER - - - - - - - - - - - GROUND WIRE -COAX COAX- COAXIAL CABLE ® ANTENNA rL CENTERLINE (E) EXISTING x DETAIL NUMBER SHEET NUMBER *� at&t Your world. Delivered. PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: �E ¢ O� NEr�EiIoONE 16926 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE 425,487.1732 FAX: 425487.1734 EMAIL: ceiCcornerslone-gr com WWW. CORNERSTONE-ENGR COM " PROJECT INFO: ISSUED FOR: IFINAL CDIS REV:= DATE:= DESCRIPTION: -BY =CK:� 0 04-13-09 ISSUE FOR FINAL CD'S JRF MWO Qq 03-26-09 ISSUE FOR CLIENT REVIEW DRA MWO L DRAWN BY: CHK:-ARV , - DRA MWp MWO CURRENT ISSUE DATE. 04-13-09 -UKAWING INY VKNIAI IVIY: DO NOT SCALE DRAWINGS, CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: GENERAL NOTES DRAWING NUMBER- G-1 0 CEI JOB NUMBER: 09.69043 (E) PARKING LOT AND DRIVEWAY (E) CURB (E) BRUSH AND TREES (E) AT&T 10'-O"x16-0" EQUIPMENT SHELTER NOTTE:E' : f OTHER CARRIER ANTENNA ARRAYS NOT SHOWN FOR CLARITY ENLARGED SITE PLAN 22x34 SCALE: 3I8" = V-0" 11107 SCALE: 3/16" _ k91CU;r I� (E) UTILITY H-FRAME (E) ICE BRIDGE (E) BRUSH AND TREES THIS IS NOT A SURVEY ALL INFORMATION AND TRUE NORTH HAVE BEEN OBTAINED FROM EXISTING DRAWINGS AND ARE APPROXIMATE. (E) 12'-0- DUAL GATE (E) 6-0" TALL CHAIN LINK (E) BRUSH ANDTREE LINE FENCE WITH BARBED WIRE PROPOSED REPLACEMENT PANEL ANTENNA ANDREW QBXLH-6565-VTM { A� (E) 120'-0" HIGH STEEL MONOPOLE (E) OTHER CARRIER CONCRETE SLAB n+ PLAN NORTH 1 at&t Your world. Delivered. = PROJECT CONSULTANTS: QGoodmanNetworks PLANS PREPARED BY: �CC7iRNER5Y0NC. -� ■ry OI INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE 425.467.1732 FAX:425487.1734 EMAIL: cei@cornerstone ngrcom WWW CORNERSTONE-ENGR,COM PROJECT INFO: rL ISSUED FOR: LFINAL MIS REV:=DATE:—DESCRIPTION:=BY:=Ci( —1 p 04-13-09 ISSUE FOR FINAL CD'S JRF MWO A 03-26-09 ISSUE FOR I CLIENT REVIEW DRA MWO DRAWN BY: CHK:=APV.: DRA MWO MWO CURRENT ISSUE DATE: 11 04-13-09 DO NOT SCALE DRAWINGS" CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED, DRAWING TITLE: ENLARGED SITE PLAN DRAWING NUM9ER: A- 00 CE1 JOB NUMBER 09-69043 PROPOSED TMA LGP 21401 MOUNTED BEHIND ANTENNA TOP OF (E) 120'-0" AGL MONOPOLE RAD CENTER OF AT&T ANTENNAS 116'-D" AGL PROPOSED REPLACEMENT PANEL ANTENNA ANDRfW OBXLH-6565 VTM 1 A� rr hRAD CENTER OF (E) ANTENNAS: r 9r-T AGL - RAD CENTER OF (E) ANTENNAS _ '1I!k93'-0" AGL RAD CENTER O_F(E)ANTENNAS — _0RAO CENTER OF IE)ANTENNAS 79'-9' AGL — GRADE PROPOSED WEST ELEVATION 22x34 SCALE: 1/8" = 1'-V I 11x17 SCALE: 1116" = 1'-0" NOTE: EXISTING ANTENNA MOUNTING HARDWARE TO BE REUSED (E) AT&T ANTENNA MOUNTING HARDWARE (E) AT&T ANTENNA PROPOSED RET (TYP) A 4 (E) OTHER WIRELESS CARRIER r ANTENNA ARRAY (E) OTHER WIRELESS CARRIER ANTENNA ARRAY (E) OTHER WIRELESS CARRIER ANTENNA ARRAY (E) 120'-0" HIGH STEEL MONOPOLE SHELTER (E) CHAIN -LINK FENCE W/ (3) STRAND BARBED WIRE ,(� TOP OF (E) MONOPOLE 4� 120'-0" AGL RA_D CENTER OF AT&T ANTE_NNAS �' 116'-0" AGL J BRAD CENTER OF (E) ANTENNAS RAD CENTER OF (E) ANTENNAS�83'•p" 'RAD CENTER OF (E) ANTENNAS _ 83'-0" AGL RAD CENTER OF(E)ANTENNAS 21 EXISTING WEST ELEVATION 2204 SCALE- 118" = 1'.p' 11 07 SCALE: MW = VAY (E) AT&T ANTENNA MOUNTING HARDWARE (E) OTHER WIRELESS CARRIER ANTENNA ARRAY (E) OTHER WIRELESS CARRIER ANTENNA ARRAY (E) OTHER WIRELESS CARRIER ANTENNA ARRAY IPMENT SHELTER (E) CHAIN -LINK FENCE W/ (3) STRAND BARBED WIRE at&t Your world. Delivered. ~ PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: �� a Or�NeFtS TONE NEERING. INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 9Bo72 PHONE: 425,467-1732 FAX: 425,487.1734 EMAIL: cei@cornerstone—gr com WWW CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR: FINAL CUS REV:= DATE: =DESCRIPTION:=BY:=CK:—I p 04-13-09 ISSUE FOR FINAL CD'S JRF MWO QA 03-26-09 ISSUE FOR CLIENT REVIEW DRA MWO DRAWN BY: CHK.:=APV.: IILL DRA MWD I MWO CURRENT ISSUE DATE: 04-13-09 LICENSURE: DRAWING INFORMATION: DO IFY NOT SCALE DRAWINGS CONTRACTOR MUST VER ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION, THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED DRAWING TITLE: EXISTING & PROPOSED WEST ELEVATION DRAWING NUMBER: A-2 0 CEl JOB NUMBER 09.690-43 SCHEDULES 2204 SCALE: NTS APPURTENANCES ITEM NEW EXISTING REMAIN REPLACE TOTAL ANTENNA 3 3 0 3 3 TMA 6 6 0 6 12 RET 3 9 9 0 12 11x17 SCALE: NTS SECTOR "Z' S� PROPOSED REPLACEMENT PANEL ANTENNA ANDREW QBXLH-6565-VTM 1 (TYP OF 3) A .. ry SECTOR "Y" z� PROPOSED ANTENNA PLAN �i SECTOR "X" (E) 120'-0" HIGH STEEL MONOPOLE PLAN NORTH COAX SCHEDULE SECTOR LENGTH #OF COAX DIAMETER PLACEMENT SECTOR X 138'-0" 6 (E) 7/8" INSIDE TOWER SECTOR Y 138'-0" 6 (E) 7/8" INSIDE TOWER SECTOR 138'-0" 6(E) 7/6'' INSIDETOWER RET 138'-0" 1 (N) 3/8"0 INSIDETOWER SECTOR "r X . (E) PANEL ANTENNA (TO BE REPLACED) (E) PANEL ANTENN< (TO BE REPLACED) YCTOR"Y" 2 EXISTINGNTENAN:LANNTENLAN22x34 SCALESCALE $g ����� SECTOR "X" (E) PANEL ANTENNA (TO BE REPLACED) (E) 120'-0" HIGH STEEL MONOPOLE PLAN NORTH K at&t Your world. Delivered. PROJECT CONSULTANTS: GoodmanNetworks PLANS PREPARED BY: �[ORNERSVON£ �� Lwerfre�Rr%4, rHc- 16928 WOODINVILLE-REDMOND RD NE SUITE 210 WOODINVILLE. WA 98072 PHONE 425,487.1732 FAX:4254871734 EMAIL: cei@cornersI0ne ngrcom W W W. CORNERSTONE-ENGR COM PROJECT INFO: ISSUED FOR: [I L.FINAL CD'S L. REV:= DATE: =DESCRIPTION:—BY:=CK:-7 Qp 04-13-09 ISSUE FOR FINAL JRF MWO Q03-26-09 A ISSUE FOR CLIENT REVIEW DRA MWO DRAWN BY: CHK.:=APV.: DRA MWO MWO r CURRENT ISSUE DATE: II`L 04-13-09 LICENSURE: W' O[ y � r � 3.. YYt7 E7fpIRES 0715571 DRAWING INFORMATION: DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED DRAWING TITLE: EXISTING AND PROPOSED ANTENNA PLANS DRAWING NUMBER: A-3 0 CEI JOB NUMBER 09.89043 NTS 111x17 NOTES: 1. TMA IS A WEATHERPROOFED ENCLOSURE RATED TO IP65. 2. BOND TMA GROUND STUD TO GROUND BAR WITH 6AWG GROUND WIRE. 3, PROVIDE SUFFICIENT LENGTH OF JUMPER TO ALLOW FOR PROPER APPLICATION OF WEATHER PROOFING AT ANTENNA AND TMA CONNECTIONS, 4. IF POSSIBLE, TMA SHALL BE MOUNTED BEHIND ANTENNA TO MINIMIZE WIND LOADING ON STRUCTURE 5 TMA SHALL BE MOUNTED VERTICALLY. METAL STRAP SUBCONTRACTOR TO PROVIDE (TYP)JUNIPER TO ANTENNA TMA �wr GROUND SCREW °n GROUND WIRE TO ANTENNA ANTENNA MOUNTING PIPE (TYP) GROUND BAR (SEE NOTE 2) JUMPER TO MAIN COAX FRONT VIEW JUMPER TO ANTENNA METAL STRAP SUBCONTRACTOR TMA TO PROVIDE (TYP) GROUND WIRE TO ANTENNA ANTENNA MOUNTING PIPE (TYP) GROUND BAR (SEE NOTE 2) - JUMPER TO MAIN COAX SIDE VIEW TMA MOUNTING DETAIL N_fS 11 IX17 SCALE: NTS (E) ANTENNA F PRIMARY LOCI OF TMA, AS PE CONDITIONS. ANTENNA AS PER ANTENNA SCHEDULE RET AS REQ'D COAXJUMPER SUPPORT COAX TO JUM KIT, GROUNDI AND CABINET. TMA ATTACHMENT 9 5/16" 9 1/16" 1 1/2" II :3" 850 ANT 1900 ANT POWERWAVE I iO N I THIS END DOIA BTS 2 5/8" 6 TMA DETAIL 22x34 SCALE- 3" = 1'-0" 5 3/16" 5 15/16" 318"0 (8x) GROUND SCREW M8 CONNECTOR 7-16 FEMALE (3x) 1x17 SCALE: 1 1/2" = l'-0- 2 3/8" O.D. GALV PIPE MAST ANTENNA--- 3 ANTENNA MOUNTING DETAIL 22x34 SCALE: NTS 11x17 SCALE: NTS 5 2 RET DETAIL 4 22x34 SCALE: NTS 111x17 SCALE: NTS 1'-1� m O v v f� FRONT BACK SIDE ANDREW ANTENNA: QBXLH-6565A-VTM TOP ANTENNA DETAIL W/ RET'S ATTACHED 22x34 SCALE: 112" = T-0" I 1107 SCALE: 114-= V-0- at&t Your world. Delivered. rr[vd­ �+ • • . GoodmanNetworks PLANS PREPARED BY: NERS ONE 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: 425487.1732 FAX:425,4071734 EMAIL: cei@cornerstone—gccom WWW CORNERSTONE-ENGRCOM PROJECT INFO: L ISSUED FOR: FINAL CD'S REV:= DATE: —DESCRIPTION:—BY:-CK: 1 FOR FINAL CD'SJRF MWO WISSUE ISSUE FOR CLIENT REVIEW DRA MWO DRAWN BY: CHK:=APV. DRA MWO MWO C CURRENT ISSUE DATE: 04-13-09 .. LICENSURE: DRAWING INFORMATION: DO NOT SCALE DRAWINGS CONTRACTOR MUST VERIFY ALL DIMENSIONS AND AOVISE CON SULTANTS OF ANY E RRORS AND 01.115SIONS. ALL PREI90US ISSUES OF TKS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE IwowATIOA CONTAINED IN THIS SET OF DGOVLIENTS 15 PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED DRAWING TITLE: ANTENNA DETAILS DRAWING NUMBER: A-4 0 CEI JOB NUMBER: 09.69043 3/4" = 1'-U" 111x17 SCALE: 3/8" = 1'_ man SWEEP TEST REQUIREMENTS: AT&T WIRELESS SEATTLE, WA. ANTENNA AND TRANSMISSION LINE TEST REQUIREMENTS REQUIRED EQUIPMENT (1) WILTRON/ANRITSU SITE MASTER S331A/B/C OR EQUIVALENT (1) OPEN, SHORT, LOAD (1) DIN FEMALE TO N TYPE MALE ADAPTER (LOW LOSS) (1) DIN MALE TO IN TYPE MALE ADAPTER (LOW LOSS) (2) DIN FEMALE TO DIN FEMALE ADAPTER (LOW LOSS) (1) PHASE STABLE CABLE (1) TRUE-RMS MULTI -METER FREOUENCIES TO BE USED PCS FREQUENCY BAND 185OMHZ-199OMHZ TRANSMIT FREQUENCY 1930MHZ-194OMHZ RECEIVE FREQUENCY 185OMHZ-186OMHZ TRANSMISSION LINE AND ANTENNA SYSTEM TEST (1) INSERTION LOSS/CABLE LOSS (2) ANTENNA/TRANSMISSION LINE DISTANCE TO FAULT (RL) (3) ANTENNA SYSTEM RETURN LOSS (4) ANTENNA SYSTEM WITH DUPLEXER/TMA/ANTENNA RETURN LOSS (5) TRANSMISSION LINE CONTINUITY TEST INS EM LO THIS TEST W3LL MEASURE THE CABLE LOSS OF THE TRANSMISSION LINE AND JUMPERS BETWEEN THE CABINET AND ANTENNA. TEST FREQUENCIES: F1=1850 F2=1990 1, ENTER THE FREQUENCIES TO BE USED IN F1 AND F2. 2. RE -CALIBRATE TEST EQUIPMENT. 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO DIN (F) CONNECTORS. 4. CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE THE ANTENNA, OF THE LINE UNDER TEST. 5, CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER (YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST. 6. PERFORM MEASUREMENT, THEN DUE STEPS 10 THROUGH 12. 7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER (.YELLOW)GREEN) TO DIN (F) ADAPTJ R. 8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER (YELLOWIGREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST 9. PERFORM MEASUREMENT, THEN DUE STEP 10 THROUGH 13. 10. ADD THE MAXIMUM PEAK TO THE MINIMUM VALLEY THEN DIVIDE BY TWO. THIS IS THE CABLE INSERTION LOSS. THIS VALUE SHOULD NOT BE GREATER THEN -4DB. 11. PEAK MAX (M1) + VALLEY MIN (M2)/2= CABLE INSERTION LOSS. 12. RECORD CALCULATED/MEASURED VALUE ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 13. REPEAT STEPS 1 THROUGH 12 FOR THE REST OF THE TRANSMISSION LINES. ANTENNA SYSTEM RETURN LOSS: THISTEST MEASURES THE RL OF THE TRANSMISSION LINE TERMINATING INTO THE ANTENNA WITHOUT THE TMA AND DUPLEXER. TEST FREQUENCIES: 171=1850 F2=1990 1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2. 2. RE -CALIBRATE TEST EQUIPMENT. 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO DIN (F) CONNECTORS. 4. CONNECT THE ANTENNA TO THE LINE UNDER TEST, 5. CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER (YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST. 6. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10 THROUGH 13. 7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER (YELLOW/GREEN) TO DIN (F) ADAPTER. 8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER (YELLOW/GREEN )BEFORE THE CABINET, OF THE LINE UNDER TEST. 9. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10 THROUGH 13. 10. VERIFY ANTENNA SYSTEM USING 1 5/8" WAVE -GUIDE HAS A RL LESS THEN -17DB, 20OFT MAX. 11. VERIFY ANTENNA SYSTEM USING 7/8" WAVE -GUIDE HAS A RL LESS THEN -16DB, 20OFT MAX. 12. FOR SYSTEMS ABOVE 20OFT 1 5/8" RL-15.5DB, 7/8" RL -14DB. 13. RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE ANTENNA SYSTEMS. ANTENNA SYSTEM WITH DUPLEXER AND TMA RETURN LOSS: PROPOSE[ THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA NETWORK ON THE TX PATH. TX TEST FREQUENCIES: F1=1930 F2=1940 PROPOSE[ REPLACEM 1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2 2. RE -CALIBRATE TEST EQUIPMENT. 3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM JUMPERS. 4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM JUMPER TO DUPLEXER. TOP JUMPI 5. CONNECT TEST EQUIPMENT TO TX 1 (YELLOW/RED), 6. PERFORM MEASUREMENT. 7. VERIFY ANTENNA NETWORK USING 1 5/8" WAVE -GUIDE HAS A DIPLEXOR RL LESS THEN-15.5DB, 20OFT MAX. GROUND E 8. VERIFY ANTENNA NETWORK USING 7/8" WAVE -GUIDE HAS A RL LESS THEN-14,5DB, 200FT MAX. NEAR ANTI 9. FOR ANTENNA NETWORK ABOVE 20OFT 1 5/8" RL-14DB, 7/8" RL-12.5DB, 10- RECORD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION. 11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE TX GROUNDIN ANTENNA NETWORKS. ANTENNA SYSTEM W ITH DUPLEXER AND TMA RETURN LOSS: ANT ENNA/TRANSMiSSION LINE DISTANCE TO LT FAURL L THIS TEST MEASURES THE RL OF THE COMPLETE ANTENNA THIS TEST IS A PERFORMANCEIGATIONAND FAILURE ANALYSIS NETWORK ON THE RX PATH. REMINDER THE TEST EQUIPMENT MAIN COA TOOL FOR THE ANTENNA, TRANSMISSION LINES AND CONNECTORS. WILL TERMINATE INTO THE TMA ON THE RX PATH. CABLE (TY TEST FREQUENCIES: F1=1850 F2=1990 RX TEST FREQUENCIES: F1=1850 F2=1860 1, ENTER THE FREQUENCIES TO BE USED IN F1 AND F2. 2, RE -CALIBRATE TEST EQUIPMENT. 3. CONNECT THE TWO JUMPERS GOING TO THE ANTENNA (BYPASS TMA) AND THE CABINET (BYPASS DUPLEXER) USING THE DIN (F) TO DIN (F) CONNECTORS. 4. CONNECT THE ANTENNA TO THE LINE UNDER TEST. 5, CONNECT TEST EQUIPMENT TO THE LAST TX JUMPER (YELLOW/RED) BEFORE THE CABINET, OF THE LINE UNDER TEST. 6. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10 THROUGH 13, 7. DISCONNECT TX JUMPER, THEN CONNECT THE RX JUMPER (YELLOW/GREEN) TO DIN (F) ADAPTER. 8. CONNECT TEST EQUIPMENT TO THE LAST RX JUMPER (YELLOW/GREEN) BEFORE THE CABINET, OF THE LINE UNDER TEST. 9. PERFORM MEASUREMENT, VERIFY RESULTS WITH STEPS 10 THROUGH 13. 10. VERIFY EACH DIN CONNECTOR HAS A RL LESS THEN -32DB, N TYPE -28DB. 11. VERIFY THE TRANSMISSION LINE HAS A RL LESS THEN -45DB, 12, VERIFY THE ANTENNA HAS A RL LESS THEN -17DB. 13, RECORD PASS/FAIL ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION, 14. REPEAT STEPS 1 THROUGH 13 FOR THE REST OF THE ANTENNA'S AND TRANSMISSION LINES. 1. ENTER THE FREQUENCIES TO BE USED IN F1 AND F2 GROUND 13 2. RE -CALIBRATE TEST EQUIPMENT. NEAR EQU 3. REMOVE DIN (F) TO DIN (F) FROM BOTH TOP AND BOTTOM JUMPERS. 4. CONNECT TOP JUMPERS TO TMA AND CONNECT BOTTOM JUMPER TO DUPLEXER. 5. CONNECT TEST EQUIPMENT TO RX 1 (YELLOW/GREEN), 6. PERFORM MEASUREMENT. DIPLEXOR 7. VERIFY ANTENNA NETWORK USING 1 5/8" WAVE -GUIDE HAS A RL LESS THEN-16.5DB, 20OFT MAX. 8. VERIFY ANTENNA NETWORK USING 7/8" WAVE -GUIDE HAS A BOTTOM J RL LESS THEN-15.5DB, 20OFT MAX. 9. FOR ANTENNA NETWORK ABOVE 20OFT 1 5/8" RL -14DB, 718" RL-13 ' 5DB. 10. RECOD TEST RESULTS ON SWEEP DATA SHEET, THEN SAVE SWEEP TO A MEMORY LOCATION, 11. REPEAT STEPS 1 THROUGH 10 FOR THE REST OF THE RX ANTENNA NETWORKS. TRANSMISSION LINE CONTINUITY TEST: THIS TEST WILL VERIFY THE CONTINUITY OF THE RX PATH BETWEEN THE BTS AND THE TMA FOR THE 15 VDC NETWORK. 1, CONNECT A SHORT AT THE END OF THE LAST JUMPER BEFORE THE TMA, OF THE LINE UNDER TEST. 2. CONNECT MULTI -METER TO LAST JUMPER BEFORE THE BTS, RX 1 (YELLOW/GREEN). PLACE THE BLACK LEAD ON THE OUTER PART OF THE CONNECTOR AND THE RED LEAD ON THE CENTER PIN OF THE CONNECTOR 3. VERIFY THE METER READS A SHORT. 4. REMOVE SHORT AND VERIFY METER READS OPEN. 5. RECORD PASS/FAIL ON SWEEP DATA SHEET. 6.. RECONNECT JUMPERS TO TMA AND BTS. 7. REPEAT STEPS 1 THROUGH 6 FOR THE REMAINING RECEIVE PATHS. r_l"11JAZIM, .;ABLE MARKING TAGS TO PROVIDE ADDITIONAL IDENTIFICATION EACH RF CABLE SHALL BE IDENTIFIED WITH A METAL TAG MADE OF STAINLESS STEEL OR BRASS AND STAMPED AS SHOWN. THE ID MARKING LOCATIONS SHOULD BE AS PER "CABLE MARKING LOCATIONS TABLE". THE TAG SHOULD BE ATTACHED WITH CORROSION PROOF WIRE AROUND THE CABLE. THE FOLLOWING ARE 3 DIFFERENT FORMATS TO BE USED FOR THE BRASS TAGS. 1A 1A 1A (D(D G9U9 FORMAT A FORMAT B FORMAT C DIAGRAM OF BRASS TAG FORMATS FORMAT A IS USED WHEN THERE IS ONLY ONE TECHNOLOGY BEING CARRIED ON A CABLE. FORMAT B IS USED WHEN TWO TECHNOLOGIES HAVE BEEN DIPLEXED ONTO ONE CABLE AND WILL BE BROKEN OUT THROUGH A DIPLEXOR AT THE TOP OF THE TOWER. FORMAT C IS USED WHEN TWO TECHNOLOGIES HAVE BEEN QUADRAPLEXED ONTO ONE CABLE FOR ANTENNA PORT SHARING AT THE TOP OF THE TOWER THE FIRST NUMBER DESIGNATES THE ANTENNA POSITION, THE SECOND CHARACTER DESIGNATES THE PORT ON THE ANTENNA, THE THIRD CHARACTER DESIGNATES THE TECHNOLOGY TYPE, AND THE LAST NUMBER DESIGNATES THE FREQUENCY BAND OF THE OSED RET'S TECHNOLOGY. B1 SECTOR 1 SECTOR 2 QSEDTMA' RF CABLES A2 RF CABLES B2 THRU B6 AS THRU A6 AS REO'D REO'D Al � Cl SECTOR 3 :R CABLE RF CABLES C2 THRU C6 AS REO'D NOTE: SECTOR ORIENTATIOWAZIMUTH WILL NEAR ANTENNAS VARY FROM REGION TO REGION AND IS IAR SITE SPECIFIC REFER TO RF REPORT FOR EACH SPECIFIC SITE TO DETERMINE THE SECTOR ORIENTATION IG KIT VIAL P) 3AR IIPMENT ALL RF CABLE SHALL BE MARKED AS PER CABLE MARKING I OCATIONS TABLE BELOW: CABLE MARKING LOCATIONS NO- ITAG LOCATIONS 1 X END OF THE MAIN COAX RUN WHERE THE COAXIAL CABLE AND JUMPER TO THE ANTENNA ARE CONNECTED. 2. X CABLE ENTRY PORT ON THE INTERIOR OF THE SHELTER (AS APPLICABLE). 3 X END OF JUMPER AT BTS CABINET CABLE COLOR MARKING IN ADDITION TO THE IMPLEMENTATION OF BRASS TAGS, CONTRACTORS SHALL USE ONE BAND OF COLOR TAPE PER CABLE FOR SECTOR DESIGNATION LABELING. THE COLORS SHALL BE AS FOLLOWS: IUMPER CABLE SECTOR A: RED SECTOR B: BLUE SECTOR C: GREEN THE SECTOR DESIGNATIONS SHALL BE MARKED AS DESCRIBED ON THE CURRENT RF DATA SHEET (RFDS) AT TIME OF INSTALLATION. RF DATA SHEET IS TO REMAIN POSTED AT EVERY SITE COAX BOOT SPECIFICATION ENTRY BOOTS TO SEAL COAX WITHIN 6" CONDUITS SHALL BE: ROXTEC H SEAL H3-150/3X(28-54)/20 SEE COAX CONDUIT EXIT SEAL DETAIL (WHEN APPLICABLE) CONTRACTOR SHALL USE THE ABOVE PRODUCTS OR APPROVED EQUAL W`� � at&t Your world. Delivered. PROJECT CONSULTANTS: GoodmanNetworks •II.•r.0 PLANS PREPARED BY: �CQPl NEFRsirONE �+ ■.MOINEENINo.INc. 16928 WOODINVILLE-REDMOND RD NE. SUITE 210 WOODINVILLE, WA 98072 PHONE: 425.467.1732 FAX:425487.1734 EMAIL: ce i@cornersto ne-gr. cam W WW.CORNERSTONE-ENGR COM , PROJECT INFO: L ISSUED FOR: FINAL CDIS REV:= DATE: =DESCRIPTION: -BY -CK:� p 04-13-09 ISSUE FOR FINAL CD'S JRF MWO A 03-26-09 ISSUE FOR CLIENT REVIEW DRA MWO DRAWN BY: CHK.: -APV -- DRA &w."O M%NO CURRENT ISSUE DATE: 04-13-09 UCENSURE1 � 1 ■ 1 ! ExPIRES D214er1D DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED :DRAWING TITLE: ANTENNA SWEEP TEST & COAX COLOR CODING :DRAWING NUMBER: A-5 0 CEI JOB NUMBER: 09.69043