Loading...
21-1053360'-- City arFederal Way Electrical C°" ¢ 33 5 8th S °`p`. Permit #:21-10533 Sal W y, AveAvc 5 6-00-EL Federal Way, WA 98003 Ph: (253) 835-2807 Fax: (253) 835-2809 Inspection Request Line: (253) 835-3060 Project Name: THE COMMONS MALL - PAD I Project Address: 1701 S COMMONS Parcel Number: 762240 0015 Project Description: BLUEBEAM - Service and wiring for new restaurant/retail building. Owner MERLONE GEIER PARTNERS 457 SW 148TH ST SUITE 202 BURIEN WA 98166 Applicant CHRIS LEEMCG ARCHITECTURE 15635 ALTON PKWY IRVINE CA 92618 Additional Permit information Is this an Online or O.T.C. application? .............. No Electrical Fixtures New Service: over 1000 amps 1 Cont�or ARCON ARCONGL798R9 (1/4/24) 2100 124TH AVE NE. SUITE 120 BELLEVUE WA 98005 PERMIT EXPIRES Saturday,18 Februar2023 Permit Issued on Friday, y, , February 18, 2 2 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: j ,: Date. 4 Approved BY Date By 10 F' at -Electrical (4055) B Y , APProved � ` , )v� Date /U//� CITY or Federal Way THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 21 105336 00 Address: 1701 S COMMONS Project: MERLONE GEIER PARTNERS FEDERAL WAY WA 98003-8548 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. 0 UFER Ground (4295) 2 ❑ Ditch cover (4030) 0 Slab/Concrete Floor (4)55 Approved Approved By Date By ® Pool Bonding (4195) Approved BY Date By 0 Feeders/Sub-panels (4045) ® Rough Electrical (4225) Approved Date ; .�i TG� GpdG✓ �� ivf N6r/i e 6� r v Y;r f�r 61 �erf °� �1,4- Date Temporary Power (4275) Approved Date YZP vedto place concreteBYDate'�2Y� 0 Service (4235) oe Approved BY Date ® Ceiling Cover (4020) Approved By Date /,Ll --41-.2J— 16e el INS 4 ❑ ::R:oughElectrical Final Electricalproved Approved❑ Right of Way Approved BY ate By Date By Date CA, EAST r 1,686.251,5276 a Bellinaham I Arlington ; Oak Harbor ��Amv.g eotest-i nc. co m Concrete Inspection & Compressive Strength Test Report PROJECT: The Commons at Federal Way JOB M 22-0345 ADDRESS: SE Corner of S. 320 Street and Pacific Highway S., Federal REPORT #: CB002 Way, WA PERMIT M 21-105280-00-CO DATE: 8/10/2022 CLIENT: Merlone Geier Management, LLC PAGE #: 1 of 3 CONTRACTOR: Arcon Tenant Improvements Contractors INSPECTOR: Kevin Richardson Placement Location: Building I - Footings and Slab -On -Grade Sample Location: Truck Chute Mid -Load Field Data: Eq. No. Supplier Corliss Resources Slump, in, (C143) 5.00 30 Mix # FL14000 Air Content, % (C231) NT Mix Description 6SK., #57, Glenium303O (WRA) Unit Weight, pcf (C138) NT Truck/Ticket # 160 / 20003823 Air/Mix Temp.,°F (C1064) 59 / 75.3 SSD Strength Required 3500 psi at 28 days Field Cure Temperature, °F 60.6 / 79.7 SSD container / Water Tank Quantity Placed, cy 109.50 Cure Method - Initial / Final Time Batched 5:42 AM Water Added on Job, gals 0 Time Sampled 6:15 AM Water Requested by Laboratory Data: Lab No. Test Age (Days) Test Date Total Load (lbs) Avg.D (in) Area (irl Compressive Strength (psi) Remarks 45604 7 08-17 56350 3,99 12.50 4510 TYPE 5: 45605 28 09-07 0 0.00 0.00 0 45606 28 09-07 0 0.00 0.00 0 45607 28 09-07 0 0.00 0.00 0 45608 Hold 00-00 0 0.00 0.00 0 Reinforcement Inspection Yes n/a: not applicable Specimen Size 4" X 8" Reinforcement Conforms Yes n/t: not tested Test Reference ASTM C31/C39/C1231 Comments: GeoTest was on site as requested to perform special inspection during placement for the slab -on -grade and footings at Building I. Reinforcing steel was inspected on 8/9/2022 - see GeoTest report IR003. The three outstanding items noted in that report were adequately addressed. Holdowns were not cast in place. Superintendent with Arcon, Jeff Crepeau, stated that they would be post -installed and he will contact GeoTest for special inspection during the installation. COPIES: Alex@arcon.construction, bgoolee@merlonegeier,com, brad ley@arcon.conslruction, fvelasquez@mcgarchitecture.com, Reviewed by jeff@arcon.conslruclion, jwilson@arcon-ti,com, nalhan@harrisoneng.com This report shall not be reproduced except in full, without the written approval of GeoTest Services, Inc The above lest results relate to the sample (or location) tested. 1888-251.5276 Bellingham I Arlington j Oak Harbor �,Avw.geotest-inc com Concrete Inspection & Compressive Strength Test Report PROJECT: The Commons at Federal Way CLIENT: Merlone Geier Management, LLC CONTRACTOR: Arcon Tenant Improvements Contractors JOB #: 22-0345 REPORT #: CB002 PAGE #: 2 of 3 Concrete was placed via boom pump and mechanically consolidated at the footings and the slab -on -grade was finished by hand and with a power screed. Superintendent indicated that the slab -would be saw cut later today and wet cured for several days. Arcon was made aware of our results prior to departing the site. Photo 1: Concrete placement in progress for the slab -on -grade. Photo 2: Placement and mechanical consolidation at the footings. GEGTEST 1888.2ST 5276 Bellingham I Ai Iington I Oak Harbor wwwgeotest-inc.com Concrete Inspection & Compressive Strength Test Report PROJECT: The Commons at Federal Way CLIENT: Merlone Geier Management, LLC CONTRACTOR: Arcon Tenant Improvements Contractors Photo 3: Superintendent asked that GeoTest note the installation of the Ufer bar. The vertical bar can be seen here (bottom of photo) in this top -down view, it was bent and continued -20' into the footing. Photo 4: Contractor taping vapor barrier at punctured locations. JOB #: 22-0345 REPORT #: CB002 PAGE #: 3 of 3 k IC7M IX S O L U T I O N S Sigma Six Solutions Inc. Test Report Project M 1008710 Prepared For: Arcon GC LLC . End User: Arcon GC LLC Report by: Joshua Warren Report Date: 9/9/2022 Sigma Six Solutions Inc. • 2200 West Valley HWY N, Suite 100, Auburn, WA 98001 • 253.333.9730 www.sigmasix.com SIGH XI �' 9 D L U T 1 O N S PROJECT REPORT Client: Project Name: Job Number: Project Lead: Project Start: Project End: Arcon GC LLC, Federal Way, WA Arcon GC LLC, Federal Way., WA 1008710 Joshua Warren 9/9/2022 9/9/2022 Service Request Ground Resistance Testing of (1) Ufer Ground System Tests Performed Ground Test via Fall -of -Potential Results/Recommendations Equipment meets NETA and manufacturer's specifications and is suitable for service. Test Procedure: 171 NEfA ID CLIENT El OTHER (SPECIFY) Sigma Six Solutions Inc • 2200 West Valley HWY N, Suite 100, Auburn, WA 98001 • 253.333.9730 www.sigmasix com SIGMASIX FULL FALL OF POTENTIAL ' SOLUTIONS (4 CUSTOMER Arcon GC LLC, Federal Way, WA JOB NO. 1008710 END USER Arcon GC LLC, Federal Way, WA SUB/SWGR ID GROUNDING FACILITY ID 32210 Pacific Highway S DEVICE/FEEDER ID FULL FALL -OF -POTENTIAL TESTED BY Joshua Warren BARCODE ID N/A DATE TESTED 9/9/2022 Other N/A TYPE OF GROUND SYSTEM: Ufer Ground SOIL CONDITION: *DRY r DAMP WET RAIN WITHIN 48HOURS: NO YES PROBE DIRECTION: NORTH SYSTEM TEST POINT: MAIN SERVICE GROUND 280 DISTANCE FROM GROUND ELECTRODE TO C IN FEET DISTANCE IN FEET GROUND ELECTRODE TO P) PERCENT OF OVERALL DISTANCE RESTSTANCE READING (OHMS) 28 10.0 % 3.01 62 56 20.0 % 4.33 S2 84 30.0 % 5.74 S2 112 40.0 % 753 0 140 50.0 % 7.65 n 1736 62.0 % 8.24 Q 196 70.0 % 8.56 52 224 800 % 1501 92 252 90.0 % 25.61 4 280 1000 % 55.23 S2 % 52 % S2 % S2 % Q % n RESULT: 8.09 ohms a Pr P, P, P, PS P6 P7 P. P1 C 55.0 50.0 45.0 40.0 U) 35.0 x 30.0 w U Q 25.0 f- w 20.0 15.0 10.0 5.0 EARTH RESISTANCE CURVE 40.0 80.0 120.0 160.0 200.0 DISTANCE FROM GROUND ELECTRODE TO P L4U.0 4601 COMMENTS: DEFICIENCIES: EQUIPMENT USED: # Manufacturer Model Serial / ID Number Type Calibration Date Calibration Due 1 AVp CIET5/4R 21-056 / 296 Ground Res 11 /30/2021 1 Sr3012022 Page 24400, REVISED 6/7/2016 CITY OF BuiW.'.'i19 Divlis. 3n Federal Wa 33325 Eighth Avenue South y Federal Way, WA 98W3-6325-6325 Phone 253.835-2607 Fax 253-835-2609 CORRECTION NOTICEt ADDRESS:, /'o, IF YOU HAVE QUESTIONS CALL PERMIT#: 949- (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of 4 k� Federal Way ; ding Divi$ion 33325 Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE IF YOU HAVE QUESTIONS CALL _ (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of