Loading...
17-104928 (2)PROJECT SUMMARY THIS PROJECT INCLUDES THE FOLLOWING SCOPE OF WORK: 1. PROPOSED MODIFICATION OF AN EXISTING TELECOMMUNICATIONS FACILITY. 2. PROPOSED REMOVAL OF SIX (6) PANEL ANTENNAS, SIX (6) REMOTE RADIO UNITS (RRU'S) WITH THE INSTALLATION OF TWELVE (12) PANEL ANTENNAS W/ RET EQUIPMENT AS REQUIRED, EIGHTEEN (18) REMOTE RADIO UNITS (RRU-S) (TWELVE (12) MOUNTED NEAR GROUND EQUIP. AND SIX (6) MOUNTED NEAR ANTENNAS), TWO (2) SURGE PROTECTORS (ONE (1) MOUNTED NEAR GROUND EQUIP. AND ONE (1) MOUNTED NEAR ANTENNAS), TWELVE (12) DIPLEXERS MOUNTED NEAR GROUND EQUIP. AND ONE (1) HYBRID CABLES. GOVERNING CODES GOVERNING CODES IBC-2015, INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS NEC-2014, NATIONAL ELECTRICAL CODE A.D.A. COMPLIANCE INSTALLATION IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAP ACCESS IS NOT REQUIRED PER A.D.A. DRAWING LEGEND I COAX coax HYBRID HYBRID OH-T OH-T OH-F OH-F OH-P OH-P UG-T UG-T UG-F UG-F U G-P U G-P --------------- Y:----------------�-- X ELEVATION MARKER XX.X 4 X XX.X SUBJECT PROPERTY LINE ADJACENT PROPERTY LINE COAX ROUTE HYBRID CABLE ROUTE OVERHEAD TELCO ROUTE OVERHEAD FIBER ROUTE OVERHEAD POWER ROUTE UNDERGRND. TELCO ROUTE UNDERGRND. FIBER ROUTE UNDERGRND. POWER ROUTE FIBER / POWER ROUTE NEW / EXISTING FENCE X DETAIL REFERENCE XX.X SECTION MARKER SITE INFORMATION SITE NAME: MARLAKE SITE ADDRESS: 34301 9TH AVE. S FEDERAL WAY, WA 98003 LATITUDE: LONGITUDE: SOURCE: PARCEL NUMBER: ZONING CLASSIFICATION: JURISDICTION: TOP OF (E) MONOPOLE: OCCUPANCY GROUP: CONSTRUCTION TYPE: 47° 17' 50.15" N (47.297265° N) 122° 19' 36.40" W (-122.326779- W) AS-BU I LTS 202104-9157 OP CITY OF FEDERAL WAY 120' AGL F.- PROJECT VICINITY MAP DRIVING DIRECTIONS FROM VERIZON BELLEVUE, WASHINGTON OFFICE: 1. TAKE 1-405 S AND 1-5 S TO WA-18 W IN FEDERAL WAY. TAKE EXIT 142E FROM 1-5 S (26.4 MI) 2. HEAD EAST TOWARD 158TH AVE SE (151 FT) 3. TURN RIGHT ONTO 158TH AVE SE (118 FT) 4. TURN LEFT ONTO SE EASTGATE WAY (0.3 MI) 5. TURN RIGHT ONTO THE SEATTLE W/SEATTLE RAMP (0.3 MI) 6. KEEP LEFT TO CONTINUE TOWARD 1-90 W (0.3 MI) 7. KEEP LEFT, FOLLOW SIGNS FOR 1-90 W/SEATTLE AND MERGE ONTO 1-90 W (1.2 MI) 8. USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON (0.8 MI) 9. MERGE ONTO 1-405 S (10.8 MI) 10. TAKE THE INTERSTATE 5 S EXIT TOWARD PORTLAND (0.3 MI) 11.MERGE ONTO 1-5 S (12.2 MI) 12. TAKE EXIT 142B FOR WA-18 W TOWARD S 348TH ST (0.3 MI) 13. CONTINUE ON WA-18 W. DRIVE TO 9TH AVE S (1.1 MI) 14. USE ANY LANE TO TURN RIGHT ONTO WA-18 W (0.4 MI) 15. CONTINUE ONTO S 348TH ST (0.2 MI) 16. TURN RIGHT ONTO 9TH AVE S 17. DESTINATION WILL BE ON THE LEFT (0.4 MI) ESTIMATED TIME: 32 MINUTES ESTIMATED DISTANCE: 27.5 MILES m 34301 9TH AVE. S FEDERAL WAY, WA 98003 ATC SITE # 91531 CONSTRUCTION DRAWINGS PROJECT CONTACTS APPLICANT VERIZON 3245 158TH AVE SE BELLEVUE, WA 98008 PROPERTY OWNER USPS SEATTLE NDC 34301 9TH AVE S FEDERAL WAY, WA 98003 TOWER OWNER AMERICAN TOWER COMPANY 10 PRESIDENTIAL WAY WOBURN, MA 01801 CONSTRUCTION MANAGEMENT VERIZON 5430 NE 122ND AVENUE PORTLAND, OR 97230 JASON FALLAU PH: 541.981.3542 ZONING AND PERMITTING CONSULTANT CENTERLINE SOLUTIONS 6623 NE 78TH COURT, SUITE B1 PORTLAND, OR 97218 EMILY ESTRADA PH: 971.270.1930, EXT. #5005 SITE ACQUISITION CONSULTANT CENTERLINE SOLUTIONS 6623 NE 78TH COURT, SUITE B1 PORTLAND, OR 97218 ALICE BUTLER PH: 971.270.1930, EXT. #5001 ENGINEER OF RECORD CENTERLINE SOLUTIONS 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 KHRISTOPHER SCOTT, P.E. PH: 303.993.3293 Know what's below. Call before you dig. DRAWING INDEX verizonwi *CENTERLINE S /a= ti 10N.", T1.0 TITLE SHEET A1.0 OVERALL SITE PLAN A1.1 ENLARGED SITE PLAN 4S1 A2.0 NEW & EXISTING ELEVATIONS A3.0 ENLARGED ANTENNA PLANS & DETAILS RF1.0 RF DETAILS GN1.0 GENERAL NOTES :.,. THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON CORPORATION SERVICES IS STRICTLY PROHIBITED. FINAL CONSTRUCTION DRAWINGS SIGN OFF REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED CONSULTANT SIGNATURE DATE SITE ACQUISITION PERMITTING CONSULTANT RF ENGINEER: CONST. MNGR. OPS MNGR. PROJECT MNGR. REGULATORY REV. RECEIVED OCT 12 2017 CITY OF FEDERAL. WAY COMMUNITY DEVELOPMENT CP PROJECT NO.: VER-17-0003-4 PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JL/JL BP SUBMITTAL i I SITE NAME: MARLAKE SITE ADDRESS: 34301 9TH AVE S. FEDERAL WAY, WA 98003 SHEET TITLE TITLE SHEET SHEET NO. 1 11 co f` ♦ (E) SUBJECT PROPERTY LINE (TYP.) - (E) ADJACENT PROPERTY LINE (TYP.) ADJACENT ZONING OP ; 1 I OVERALL SITE PLAN f NOTE: I If ! SITE PLAN DERIVED FROM: EXISTING DRAWINGS, GIS, AERIAL IMAGES, DEED AND SITE PHOTOS. ADJACENT ZONING ; OP /�'�",,,,, ! ugh r'' f i �%o, ��. ` fJ q,�,�,00a• ,�,�q�"oagrq,Y"o` �--------- ---- — ---- --- j )t r Fii.F y�„� j/n, `fr ,f/,', iiic �`ff�, f y %�/', °��'i r� �'•/ ''U"`o'. /i`% �'�y jyh� o t j A-C.,Y �/,z !o r . ?/Q, � 11/10, f I y i . i �us f /`,, i If j (E) ASPHALT PARKING LOT 7 I ''/l' INGRESS I EGRESS FROM 9TH AVE S. , ! 1 i 4 = i �i m i cn �. I i f i �U } ee R, 1 y lc "A� j t {� ! �� i ,; / / QW./ l / ,01 Pww/ f' / f sr. SCALE: 1" = 100'-0" (11X17) 0' 50' 100, SCALE: 1" = 50'-0" (22X34) 16%1!!!% 15.40 N If TN MN W E S 200' vo`/ OCENTERLINE SOLUTIONS PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JUCL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JUJL BP SUBMITTAL SITE NAME: MARLAKE SITE ADDRESS: 34301 9TH AVE S. FEDERAL WAY, WA 98003 SHEET TITLE OVERALL SITE PLAN SHEET NO. Al 00 gg •s, 'y9 t �iy y./y , i Y Y 4 (N) VERIZON SURGE PROTECTOR MOUNTED TO (E) CABLE BRIDGE POST NEAREST GROUND EQUIP. y (E) VERIZON EQUIP. w MOUNTED TO CONC. PAD Cm.H (E) VERIZON TELCO CABINET ?l (E) UTILITY H-FRAME W/ VERIZON AND MISC. EQUIP. (E) VERIZON GEN PLUG 21 f� U� f (E) VERIZON ems'" yy SAFTEY BOX , H i r °. ZL �' � :,�� err/• le* sk Wf q� / ,• j PIy!, a0 4•r!f �H t OT p'q&KeNG ENLARGED SITE PLAN - PROPOSED (E) TREE (TYP.) (E) TELCO BOX (E) OTHER CARRIER UTILITY H-FRAME AND MISC. EQUIP. 15.40 N TN MN E S SCALE: 1 /4"= V-0" (11 X17) 0' 2' 4' 8' SCALE: 1 /2" = V-0" (22X34) I %%�� verizon� OCENTERLINE SOLUTIONS / PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JL/JL BP SUBMITTAL SITE NAME: SITE ADDRESS: 34301 9TH AVE S. FEDERAL WAY, WA 98003 SHEET TITLE ENLARGED SITE PLAN SHEET NO. UK NOTE: PM/GC TO VERIFY PAINTING REQUIREMENTS WITH JU RISDICTION PRIOR TO ORDERING SUPPORT STRUCTURES, ATTACHMENTS, verizow ANTENNAS, AND OTHER APPURTENANCES. STRUCTURAL NOTES / VERIZON STRUCTURAL SERVICES COMPLIANCE NOTE: NO WORK SHALL COMMENCE WITHOUT THE 40CENTERL IN E APPROVED STRUCTURAL TOWER/ANTENNA/ SOLUTIONS MOUNT ANALYSIS REPORT (SIGNED AND SEALED) TO BE PROVIDED UNDER SEPARATE COVER. CONTRACTOR PRIOR TO CONSTRUCTION SHALL REVIEW THE APPROVED TOWER/ANTENNA/MOUNT ANALYSIS REPORT SUPPLIED BY VERIZON AND MODIFY IF REQUIRED ALL APPLICABLE MEMBERS AS INDICATED IN CERTIFIED STRUCTURAL REPORT PRIOR TO INSTALLATION ON STRUCTURE. E TOP OF MONOPOLE (E) TOP OF O MONOPOLE 120'-0"� 120'-0" _= yfWAS, ps E OTHER CARRIER ANTENNAS (E) OTHER CARRIER ANTENNAS (E) i y %s N VERIZON ANTENNA TIP HEIGHT E HEIGHT VERIZON ANTENNA TIPi 991-211 99 -2 fill (N) VERIZON ANTENNAS AND (E) VERIZON ANTENNAS TYP OF (6) AND VERIZON RRU'S TYP OF (6). I ANCILLARY EQUIP. MOUNTED TO {N) CP PROJECT NO.: VER-17-0003-4 MOUNTED TO (E) T-ARMS TO BE T-ARMS; SUITABILITY AND CAPACITY ' REMOVED ;i OF MOUNT FOR FINAL LOADING 1: CONFIGURATION TO BE VERIFIED BY OTHERS PRIOR TO INSTALLATION (E) OTHER CARRIER ANTENNAS (E) OTHER CARRIER ANTENNAS F i i Sf i F i F i i i i 3 i i i i i (i f { i �- (E) 120'-0" MONOPOLE (E) 120'-0" MONOPOLE PRELIMINARY NO. DATE DiC DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JUCL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JL/JL BP SUBMITTAL ANTENNA AND ANCILLARY EQUIPMENT SCHEDULE SECTOR QTY. (N)/(E) SERVICE TYPE ANTENNA MODEL # OR EQUIPMENT SPECIFICATION DIMENSIONS WEIGHT TIP HEIGHT AZIMUTH MECH. DOWNTILT ELEC. DOWNTILT CABLE QUANTITY CABLE TYPE ALPHA 2 (N) 700/850 PCs OCT458KB000OX 15.6"W X 7.4"D X 91.7"L 75 LBS 99.02' 800 00 70-U 40-H 4 (E) 7/8" COAX 2 (N) AWS QUAD456WO00OX 16.0"W X 3.9"D X 66.4"L 58 LBS 99.02' 800 00 20 1 (N) AWS RRUS-32 B66A 12.5"W X 7.4"D X 27.6"L 56 LBS - - - _ 1 (N) 700/850 PCs RRUS-32 B2 12.5"W X 7.4"D X 27.6"L 56 LBS 1 (N) - SURGE PTCTR. OVP BOX (RXXDC-3315) 12.2"W X 16.7"D X 29.1"L 32 LBS - - - - 1 (N) 1.09" HYBRID BETA 2 (N) PCs OCT458KB000OX 15.6"W X 7.4"D X 91.7"L 75 LBS 99.02' 1800 00 70-U 4°-H 4 (E) 7/8" COAX 2 (N) AWS QUAD456W000OX 16.0"W X 3.9"D X 66.4"L 58 LBS 99.02' 1800 00 60 1 (N) AWS RRUS-32 B66A 12.5"W X 7.4"D X 27.6"L 56 LBS - - _ _ 1 (N) 700/850 PCs RRUS-32 B2 12.5"W X 7.4"D X 27.6"L 56 LBS - - - _ GAMMA 2 (N) PCs OCT458KB000OX 15.6"W X 7.4"D X 91.7"L 75 LBS 99.02' 2800 00 00 4 (E) 7/8" COAX 2 (N) AWS QUAD456W000OX 16.0"W X 3.9"D X 66.4"L 58 LBS 99.02' 2800 00 00 1 (N) AWS RRUS-32 B66A 12.5" V1/ X 7.4"D X 27.6"L 56 LBS - - - _ 1 (N) 700/850 PCs RRUS-32 B2 12.5"W X 7.4"D X 27.6"L 56 LBS GROUND 1 (N) - SURGE PTCTR. OVP BOX (RXXDC-3315) 12.2"W X 16.7"D X 29.1 "L 32 LBS 12 (N) 700/850 DIPLEXER 12.5"W X 7.4"D X 27.6"L 8 (N) 700 RRUS-1313 12.5"W X 7.4"D X 27.6"L 56 LBS 8 (N) 850 RRUS-B5 12.5"W X 7.4"D X 27.6"L 56 LBS O y Uo verizon = 2 Q (E) VERIZON (700) ANTENNA ry W (TYP. OF 3) TO BE REMOVED 10CENTERLINE O SOLUTIONS W O W -H (E) VERIZON (AWS) ANTENNA a I- gZIMUTA SECTOR (TYP. OF 3) TO BE REMOVED Q �_ Ty ' + 1000'-•- W �.- (E) 120'-0" MONOPOLE TOWER; OTHER CARRIER ANTENNAS NOT SHOWN FOR CLARITY 000 qZi BET q SECTO +r MUTH _ + 1000 1 ANTENNA AND COAX/FIBER SCHEDULES bUALE:NTS SCALE: 3/16"=1'-0"(11X17) o' 5' 10, SCALE: NTS 3 ANTENNA PLAN - EXISTING SCALE. 3/8 - 1, -0 (22X34) : (N) VERIZON RRU MOUNTED O NEAR ANTENNAS (TYP. OF 6) (N) VERIZON (PCS) ANTENNA (N) ANTENNA MOUNT WITH (TYP. OF 6); SEE 2/A2.0 MECHANICAL DOWN TILT N VERIZON ANTENNA N qWS Gq� CS pa-pHA S� O_�-- () ��MV SECTOR N�..,.�MV t { = 80 (N) VERIZON (AWS) ANTENNA TH' 28p0 (N) RRU(S) W/ MOUNTING (TYP. OF 6); SEE 2/A2.0 BRACKET TOP AND BOTTOM SECT 5, Vft- N qwS GgMM N PCS p,�80 A (N SURGE PROTECTION q S TH ° PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JL/JL BP SUBMITTAL ---- gZ/ U ti1 ECTOR AZ�MU UNIT W/ MOUNTING BRACKET (BEYOND) (N) VERIZON SURGE PROTECTOR TH = 280° - � ' MOUNTED ON T ARM Aws ALPHA SECTORSITE NAME: i NOTES: N ° - VERIFY ANTENNA MOUNTING N ANTENNA SECTOR T-ARM N PCS GAA4 Ax�MUTH = 80 c) KIT q SECTOR MARLAKE WITH TOWER STRUCTURAL SITEPRO PN# RMV12-472 OR gZ�MUTH � 28 ° - (N) JUMPER W/ 10" MIN. EQUAL 0 SECTOR RADIUS ON DRIP LOOP; ALL (N) 2-3/8" O.D. MIN. ANTENNA N A�VS A 80HA i-' JUMPERS TO BE SECURED AS PIPE MOUNT(TYP) N P AZ��UTH SITE ADDRESS: REQ'D W/ (N) CABLE _� CS GAA4 34301 9TH AVE S. SUPPORTS, TYP. --� (N) COLLAR MOUNT AZ1AM4 S crOR FEDERAL WAY, WA 98003 28p° (E) 120 -0" MONOPOLE TOWER; I OTHER CARRIER ANTENNAS NOT (E) MONOPOLE 2 SHOWN FOR CLARITY ' SHEET TITLE (N) SECTOR T-ARM KIT (N) GABLES; SUPPORT CABLES WI SITEPRO PN# RMV12-472 2 �N 'a GOON ENLARGED IN 12 OF SURGE PROTECTOR W/ OR EQUAL GOON S �p� HOIST GRIPS PER MFR'S G c� N ? cp � � 1540 ANTENNA PLANS REQUIREMENTS N -S.�� - �� �`-� (P �n N & DETAILS (E) COAX PORT o 13 � o° P t"I O TN MN n �� W O kiN 013 E SHEET NO. S 2 F-- ANTENNA MOUNT DETAIL SCALE: NTS SCALE: 3/16" = 1'-0" (11X17) 0' S' 10' A3mO SCALE: NTS 4 ANTENNA PLAN -PROPOSED _ SCALE. 3/8„- 1'-0" (22X34) YL6�66� SE, 'CT R 2 SEECT 3 OCENTERLINE SOLUTIONS PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 10-04-17 JL/JL BP SUBMITTAL SITE NAME: MARLAKE SITE ADDRESS: 34301 9TH AVE S. FEDERAL WAY, WA 98003 SHEET TITLE RF DETAILS SHEET NO. &ALI GENERAL NOTES 1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER. 4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND WITH LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 5 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON SITE WHENEVER ANY PERSONNEL ARE ON SITE. 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR LANDLORD. 12. ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS -BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTI9LITIES WHETHER SHOWN HERON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF THIS WORK. 17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO MATCH EXISTING. 18. ALL ELEMENTS OF EXISTING STRUCTURE TO REMAIN UNDISTURBED, UNLESS NOTED OTHERWISE. EXISTING STRUCTURE IS ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR DETERIORATION. CONTRACTOR TO VERIFY ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION AND NOTIFY ENGINEER OF RECORD IF ANY DAMAGE, DETERIORATION OR DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND. SPECIAL INSPECTION 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR. 2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED. 3. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL INSPECTOR TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. 4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED IF THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT CERTIFYING THAT ALL WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE IN CONFORMANCE WITH THE APPROVED PERMIT PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS. STRUCTURAL NOTES GENERAL STRUCTURAL NOTES: 1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES. 3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD VERSION WIRELESS AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF VERIZON WIRELESS WIRELESS OR THE ARCHITECT/ENGINEER. 5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION OF SUCH ITEMS. 6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. 8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF THIS WORK. 9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. 10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS, ETC.) SHALL BE REPLACED TO MATCH EXISTING. THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION: A. THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE ARCHITECT/ENGINEER, AND OTHER DESIGNATED PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND THE BUILDING OFFICIAL. C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. D. COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS. STANDARD STRUCTURAL STEEL NOTES: 1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM A123-A123M-02 UNLESS NOTED OTHERWISE. 2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE A OR A501. 3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION", 14TH EDITION. 4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A307 BOLTS (5/8" DIA. UNO) AND SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY -HEX NUTS AND STANDARD CUT WASHERS. 5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL GRATING MAY USE 5/8" DIA GALVANIZED ASTM A307 BOLTS U.N.O. 6. ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B. SPECIAL INSPECTION: 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR PER CODE FOR THE FOLLOWING ITEMS. A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS: INSPECT HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER ICC REPORT. DRAWING ABBREVIATIONS AFF ABOVE FINISH FLOOR LF LINEAR FEET AGL ABOVE GRADE LEVEL MAX MAXIMUM AWG AMERICAN WIRE GAUGE MECH MECHANICAL AC AIR CONDITIONING MFR MANUFACTURER ADJ ADJUSTABLE MGR MANAGER APPROX APPROXIMATELY MIN MINIMUM AZ AZIMUTH MISC MISCELLANEOUS BLDG BUILDING MTL METAL CM CONSTRUCTION MANAGER MTZL METALIZE(D) CAB CABINET MW MICROWAVE CL CENTERLINE NEC NATIONAL ELECTRICAL CODE CLG CEILING NIC NOT IN CONTRACT CLR CLEAR NTS NOT TO SCALE CO COPPER N/A NOT APPLICABLE CONC CONCRETE OC ON CENTER COND CONDUIT OD OUTSIDE DIAMETER CONST CONSTRUCTION OP OVERHEAD POWER CONT CONTINUOUS OT OVERHEAD FIBER CPM CASCADIA PM OPP OPPOSITE D/C DRAFTER/CHECKER PL PROPERTY LINE DEMO DEMOLISH PLYWD PLYWOOD DIA DIAMETER PM PROJECT MANAGER DIM DIMENSION PROJ PROJECT DN DOWN PROP PROPERTY DTL DETAIL PT PRESSURE TREATED DWG DRAWING RO ROUGH OPENING EA EACH ROW RIGHT OF WAY ELECT ELECTRICAL RRU REMOTE RADIO UNIT ELEV ELEVATION REQ REQUIRED EQ EQUAL SBTC SOLID BARE TINNED COPPER EQUIP EQUIPMENT SF SQUARE FEET EXT EXTERIOR SHT SHEET FIN FINISH SPEC SPECIFICATION FLR FLOOR SQ SQUARE FT FOOT, FEET SS STAINLESS STEEL GA GAUGE STL STEEL GALV GALVANIZED STRUCT STRUCTURE, STRUCTURAL GC GENERAL CONTRACTOR TOC TOP OF CONCRETE GWB GYPSUM WALL BOARD TOM TOP OF MASONRY GR GRADE THRU THROUGH GRND GROUND TNND TINNED HVAC HEATING, VENTING & AIR CONDITIONING UBC UNIFORM BUILDING CODE HORIZ HORIZONTAL UG UNDERGROUND HT HEIGHT UNO UNLESS NOTED OTHERWISE IBC INTERNATIONAL BUILDING CODE UP UNDERGROUND POWER ID INSIDE DIAMETER OF UNDERGROUND FIBER IN INCH VIF VERIFY IN FIELD INSUL INSULATION VERT VERTICAL INT INTERIOR WP WATERPROOF JBOX JUNCTION BOX W/ WITH LB(S) POUND(S) W/O WITHOUT verizon CENTERLI N E SOLUTIONS CP PROJECT NO.: VER-17-0003-4 PRELIMINARY NO. DATE D/C DESCRIPTION 0 03-10-17 JL/CL 90% CD REVIEW 1 04-28-17 JL/CL CLIENT COMMENT 2 05-22-17 JL/CL RF COMMENT SUBMITTAL D/C DESCRIPTION -17 JL/JL BP SUBMITTAL MTE SITE NAME: MARLAKE SITE ADDRESS: 34301 9TH AVE S. FEDERAL WAY, WA 98003 SHEET TITLE GENERAL NOTES SHEET NO. GN1 00