May 12, 2006
Doug Garner
Hammes Company
1325 4 h Avenue, Suite 1035
Seattle, WA 98101
RE: File #06-101077-00-UP; DIRECTOR'S DECISION
St. Francis Hospital Loading Dock Reconfiguration & Mechanical Room Construction
34515 9`h Avenue South, Federal Way, WA
Dear Mr. Garner:
The City has completed Process I Land Use Review and conditionally approves the proposed loading
dock relocation and mechanical equipment room construction at the existing Hospital located at 34515 91h
Avenue South. Formal plans were submitted on March 7, 2006, and a resubmittal received on April 13,
2006. The zoning for the site is Office Park (OP). The hospital use is permitted within the OP zoning
district pursuant to Federal Way City Code (FWCC) Section 22-831 "Hospital."
The applicant proposes to relocate the loading dock to accommodate a future ICU/PCU expansion, and to
cover the dock with a metal canopy. In addition, the applicant proposes to construct within the central
plant area on the northwest side of the building a new 1,040 square -foot electrical switch gear room to
accommodate a new generator along with new air cooled chiller. This building is proposed to be
constructed of CMU walls. The building and the new canopy will be painted consistent with the existing
building colors.
As noted, the loading dock relocation is proposed as phase one of an ICU/PCU expansion to be located
over the existing Emergency Room portion of the Hospital. With the ICU/PCU expansion, exiting paths
must be established at the loading dock to accommodate the future expansion. Required exit paths from the
ICU/PCU expansion cannot cross the loading dock unless there are other conforming exits we are not
aware of. Therefore, a ramp shall be provided from the easternmost corner of the loading dock to the
ground level as depicted on the red -lined site plan. Alternatively, an exit path location outside of the
loading dock can be identifed by the applicant. A building permit is required for the proposed Phase I
improvements.'
The proposed improvements do not reduce required parking, landscaping, buffering, open space, or public
areas; do not change the location of utilities or easements; are consistent with and support the approved
architectural design; and creates no impacts to sensitive areas or significant -trees. As conditioned, the
loading dock reconfiguration will maintain existing and future building egress and pedestrian connection.
Based on the City's review, the Process I application to relocate the loading dock and construct a building
to house mechanical equipment is conditionally approved as follows:
Construction permit 06-102054-CO has been submitted and is under review.
Mr. Garner
May 12, 2006
Page 2
Condition of Approval
Prior to issuance of construction permits, an exit ramp shall be depicted on the construction drawings
based on the red -lined plan sheet A-102 dated April 10, 2006, prepared by Callison Architecture, Inc.,
unless an alternative exiting path outside of the loading dock is approved by the Building Department.
This decision shall not waive compliance with future City of Federal Way codes, policies, and standards
relating to this project site. The effective date of decision is May 15, 2006, or three days from the date of
this letter. Pursuant to FWCC Section 22-355(a), any person who received notice of the administrative
decision may appeal this decision to the Federal Way Hearing Examiner by May 29, 2006 (14 days from
the effective date of decision).
In that you are the only party of record, you may waive your right to appeal by submitting a letter to this
effect to the City of Federal Way, Department of Community Development Services. If you waive your
right to appeal, you may begin work on May 15, 2006, assuming you have obtained the necessary
building permit approvals.
Additional hourly Process I fees in the amount of $198 (4.0 hours at $66 per hour less a one -hour deposit
of $66.00) are due at this time and shall be paid prior to building permit issuance.
If you have any questions, please call Associate Planner Deb Barker at 253-835-2642.
Sincerely,
eazL�_ mcckt"It92 -
Kathy McClung, Director
Community Development Services
enc: Red -lined approved site plan dated April 10, 2006, prepared by Callison Architecture Inc.
Approved elevations prepared by Callison Architecture, Inc. dated April 10, 2006
c: Deb Barker, Associate Planner
Kevin Peterson, Public Works Engineer
Scott Sproul, Assistant Building Official
Greg Brozek, South King Fire
Brian Asbury, Lakehaven Utility District
06-101077
Doc LD 36287
CITY OF
�. Federal Way
June 20, 2006
Mr. Doug Garner
Hammes Company
1325 4`h Avenue, Suite 1035
Seattle, WA 98101
RE: File #06-102054-00-CO; PLANNING DEPARTMENT REVIEW
St. Francis Hospital Loading Dock and Electrical Room
Dear Mr. Garner:
FILE
CITY HALL
33325 8th Avenue South
Mailing Address: PO Box 9718
Federal Way, WA 98063-9718
(253) 835-7000
www.cityoffederalway.com
The City has received resubmitted information for the building permit for the proposed loading dock
reconfiguration and electrical room at the St. Francis Hospital in Federal Way. Process I land use
approvalwas granted on May 12, 2006.
The Planning Department reviews building permit applications for consistency with land use decisions.
The City .ranted land use approval of the loading dock reconfiguration and new electrical room project
subject to the following condition:
Prior to issuance of construction permits, an exit ramp shall be depicted on the construction
drawings based on the red -lined plan sheet A-102 dated April 10, 2006, prepared by Callison
Architecture, Inc.; unless an alternative exiting path outside of the loading dock is approved by
the Building Department.
To date, as no information to address this condition has been received, I am unable to sign off on this
building permit. When resubmitting, please provide five copies of any revised plans with the enclosed
resubmittal form.
I can be reached at 253-835-2642 if you have any questions about this letter.
Sincerely,
Deb Barker
Acting Senior Planner
enc: Resubmittal Information Form
c: Scott Sproul, Assistant Building Official
06-102054 Doc, I.D. 36884
Deb barker - St. Francis Hospital Leading Dock Reconfiguration & Mechanical Room Construction {06-101077-OU-UP Rage 1
From: "Brian Asbury' <BAsbury@lakehaven.org>
To: "Scott Sproul" <Scott.Sproul@cityoffederalway.com>
Date: 5/25/2006 8:50:02 AM
Subject: St. Francis Hospital Loading Dock Reconfiguration & Mechanical Room Construction
(06-101077-00-UP)
Scott,
Just FYI and reiterating our previous comments on this - no side sewer
permit will be required to plumb the drain from the compactor/dock area
back into building plumbing, but a Discharge Agreement will need to be
executed to address this 'non-standard' (and other standard) discharge
configuration. Doug Garner has previously been informed of this, but
I'll also follow-up with a message to him stating the same (and moving
forward with the Discharge Agreement process).
Let me know if you have any questions or need additional information.
Brian Asbury
Engineering Technician III
Lakehaven Utility District
http://www.lakehaven.org
FAX 253-529-4081
NOTE: Lakehaven Utility District neither warrants nor guarantees the
accuracy of any facility information provided. Facility locations and
conditions are subject to field verification. All fees and charges
subject to change without notice.
CC: "Deb Barker" <Deb. Barker@cityoffederalway.com >
CITY OF
�. Federal
April 5, 2006
Mr. Doug Garner
Hammes Company
1325 4f` Avenue, Suite 1035
Seattle, WA 98101
CITY HALL
�� 33325 Sth Avenue South
Mailing Address: PO Box 9718
Federal Way, WA 98063-9718
(253) 835-7000
www.cityoffederalway.com
Re: File #06-101077-00-UP; Complete Application/Additional Information Requested
St. Francis Hospital - Loading Dock Reconfiguration/Central Plant Addition
34515 9'h Avenue South, Federal Way, WA
Dear Mr. Garner:
On March 7, 2006, the City of Federal Way's Department of Community Development Services received
your Process I land use application reconfiguration of the existing loading dock and compactor, as well as
reconfiguration of the existing central plant to include a new 1,040 square foot electrical gear switch room
for the new generator and air cooled chiller for the existing hospital. The site is zoned Office Park (OP).
Hospital uses are permitted pursuant to Federal Way City Code (FWCC) Section 22-831. According to code
regulations, upon receipt of an application the City has 28 days to determine whether all information and
documentation required for a complete application pursuant to FWCC Section 22-33 has been submitted.
NOTICE OF COMPLETE APPLICATION
Please consider this letter as a Letter of Complete Application. Pursuant to the FWCC, the application is
deemed complete as of March 30, 2006, based on a review of your submittal relative to those requirements
as set out in the Development Requirements Checklist.
Having met the submittal requirements, your application is now ready for processing. The Department of
Community Development Services has responsibility to notify other agencies that may have jurisdiction
over your development project or an interest in it.
TECHNICAL COMMENTS
The following items were identified in reviewing the application for completeness.
Planning Division — Deb Barker, 253-835-2642
Site Plan: The following information must be provided prior to Process I approval:
1. Depict the existing configuration of the loading dock and central plant, including existing
loading dock and trash compactor locations and existing mechanical equipment units.
File N06-101077-00-UP Doc. I D. 35689
Mr. Doug Garner
Page 2
April 5, 2006
2. Label pedestrian connections and pathways proposed for the revised loading dock. Is there
a grade change between the proposed compactor location and the western most truck bay?
3. Show full location of canopy on site plan.
4. Shear walls should be depicted if they are part of phase H.
Public Works Traffic Division, Raid Tirhi, 253-835-2744
Traffic mitigation measures will be included as part of the second phase of the ICU-PCU expansion project.
Please see the December 2, 2005, revised traffic comments from file #05-105889-00-PC.
South King Fire and Rescue, Greg Brozek, 253-946-7241
The Fire Marshal's Office requirements will be addressed during the plan review process associated with
construction permits.
Lakehaven Utility District, Brian Asbury, 253-946-5407
Lakehaven's previous comments on this issue with regard to drainage from the trash compactor area still
apply. If this area is not covered, then the applicant will be required to submit semi-annual discharge
volume reports to Lakehaven for the purpose of monitoring precipitation flows into the sanitary sewer
system. Lakehaven understands that the applicant intends to route the drainage from the trash compactor
area through a pump and back into the building to connect to building plumbing, which ultimately drains
to the sanitary sewer system. This will not require a Side Sewer Permit from Lakehaven as no physical
connection is proposed to either an existing public sewer main or an existing building sewer line. The
applicant should continue to coordinate the construction of the compactor drainage system with
Lakehaven Utility District.
Please note that Process I land use approval can be issued following submittal of requested information to
satisfactorily address the land use comments. Please submit five copies of any requested plans, along with
the enclosed resubmittal form.
If you should have any questions regarding this letter or your development project, please feel free to call
me at 253-835-2642.
Sincerely,
Deb Barker
Associate Planner
Enc Resubmittal Information Form
c: Kevin Peterson, Public Works Engineer
Raid Tirhi, Public Works Senior Traffic Engineer
Brian Asbury, Lakehaven Utility District
File H06-101077-00-UP Doc ID 35689
C�7
CHICAGO TlTLE"INSURANCE COMPANY
701 FIFTH AVENUE, #3400, SEATTLE, WA 98104
FJESUBMITTED ORDER NO:
G�7 YOUR NO:
UNIT NO:
APR 3 LOAN NO:
BUILDINGOF FEDERALWA-,
fl PTo.
SUPPLEMENTAL COMMITMENT
PHONE: (206)628-5623
FAX (206)628-56.7
001153726
ST. FRANCIS HOSPITAL
10
O R D E R R E F S R S N C S I N F O R M A T I O N
SUPPLEMENTAL NUMBER: 1
SELLER:
PURCHASER/BORROWER: ST. FRANCIS HOSPITAL
PROPERTY ADDRESS: WASHINGTON
Our Title Commitment dated 01/03/05 at 8:00 A.M. is supplemented as follows:
rs THE FOLLOWING PARAGRAPH(S) HAS (HAVE) BEEN ADDED TO OUR COMMITMENT:
ra PARAGRAPH NUMBER 84:
rr 1. LICENSE, INCLUDING THE TERMS AND CONDITIONS THEREOF:
GRAR: FRANCISCAN HEALTH SYSTEM -WEST, A WASHINGTON
CORPORATION
GRAE: CITY OF FEDERAL WAY
RECORDED: DECEMBER 16, 2005
RECORDING NUMBER: 20051216000474
AFFECTS: PARCEL B
>L
rr
THERE HAS BEEN NO CHANGE IN THIS COMMITMENT SINCE JANUARY 3, 2005, EXCEPT THE
MATTERS NOTED HEREINABOVE.
DECEMBER 28, 2005 AUTHORIZED BY: MIKE HARRIS
surpt=M/RDA am
CHICAGO TITLE INSURANCE COMPANY
701 FIFTH AVENUE, #3400, SEATTLE, WA 98104
PHONE: {2W62&5623
FAX ({ 62&5557
ORDER NO: 001153726
YOUR NO: ST. FRANCIS HOSPITAL
UNIT NO: 10
LOAN NO:
SUPPLEMENTAL COMMITMENT #2
>w
O R D E R R x F$ R B H C B I N F O R M A T I O N
SUPPLEMENTAL NUMBER: 2
SELLER:
PURCHASER/BORROWER: ST. FRANCIS HOSPITAL
PROPERTY ADDRESS: WASHINGTON
Our Title Commitment dated 01/03/05 at 8:00 A.M. is supplemented as follows:
rs PARAGRAPH NUMBER(S) 40, 41, 42, 43, 45, 47, 50, 53 AND 55 HAS (HAVE) BEEN
AMENDED AS FOLLOWS:
rs PARAGRAPH NUMBER 40:
a� 1. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1 OF
THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR: 2006
TAX ACCOUNT NUMBER: 750451-0050-03
LEVY CODE: 1205
ASSESSED VALUE -LAND: $ 660,200.00
ASSESSED VALUE -IMPROVEMENTS: $ 5,455,900.00
GENERAL & SPECIAL TAXES: BILLED: $ 75,008.26
PAID: $ 0.00
UNPAID: $ 75,008.26
AFFECTS: LOT 1
ru PARAGRAPH NUMBER 41:
or 2. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1 OF
THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
SEE NEXT PAGE
surrc:0M2/s NM9
go
jw
CHICAGO TITLE INSURANCE COMPANY
Order No.: 1153726
Your No.: ST. FRANCIS HOSPITAL
Unit No.: 10
SUPPLEMENTAL COMNIITMENT
(Continued)
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS
GENERAL & SPECIAL TAXES:
AFFECTS. LOT 2
PARAGRAPH NUMBER 42:
2006
750451-0040-06
1205
$ 386,300.00
$ 0.00
BILLED: $ 6,277.56
PAID: $ 0.00
UNPAID: $ 6,277.56
3. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS
GENERAL & SPECIAL TAXES:
AFFECTS: LOT 3
PARAGRAPH NUMBER 43:
2006
750451-0030-08
1205
$ 176,900.00
$ 0.00
BILLED: $ 2,854.97
PAID: $ 0.00
UNPAID: $ 2,854.97
aff 4. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS:
GENERAL & SPECIAL TAXES:
2006
750451-0010-02
1205
$ 217,600.00
$ 0.00
BILLED: $ 3,529.09
PAID: $ 0.00
UNPAID: $ 3,529.09
9UPLC0M2/RDA/0M
n
ar
rs
HA
CHICAGO TITLE INSURANCE COMPANY
Order No.:
Your No
Unit No.:
SUPPLEMENTAL COAIIVIITMENT
(Continued)
AFFECTS: LOT 4
PARAGRAPH NUMBER 45:
1153726
ST. FRANCIS HOSPITAL
10
5. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS:
GENERAL & SPECIAL TAXES
2006
750451-0060-01
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 2,325.40
PAID: $ 0.00
UNPAID: $ 2,325.40
AFFECTS: SPECIAL TAXES FOR AS TO LOT 5
PARAGRAPH NUMBER 47:
6. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS
GENERAL & SPECIAL TAXES:
2006
750451-0020-00
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 4,208.10
PAID: $ 0.00
UNPAID: $ 4,208.10
AFFECTS: SPECIAL TAXES AS TO LOT 6
PARAGRAPH NUMBER 50:
7. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
suers )WJPM /0M
as
az
as
CHICAGO TITLE INSURANCE COMPANY
Order No.:
Your No.:
Unit No.:
SUPPLEMENTAL COMMMENT
(Continued)
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE —LAND:
ASSESSED VALUE —IMPROVEMENTS:
GENERAL & SPECIAL TAXES:
1153726
ST. FRANCIS HOSPITAL
10
2006
750451-0070-09
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 598.32
PAID: $ 0.00
UNPAID: $ 598.32
AFFECTS: SPECIAL TAXES AS TO LOT 8
PARAGRAPH NUMBER 53:
8. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE —LAND:
ASSESSED VALUE—IMPROVEMENTS-
GENERAL & SPECIAL TAXES:
2006
750451-0090-05
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 851.78
PAID: $ 0.00
UNPAID: $ 851.78
AFFECTS: SPECIAL TAXES AS TO TRACT "X"
PARAGRAPH NUMBER 55:
9. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE —LAND:
ASSESSED VALUE —IMPROVEMENTS:
GENERAL & SPECIAL TAXES
2006
202104-9038-04
1205
$ 670,500.00
$ 0.00
BILLED: $ 7,910.74
PAID: $ 0.00
s Ul'LCOM2/RDA/0999
TCHICAGO TITLE INSURANCE COMPANY
Order No.: 1153726
YourNo.: ST. FRANCIS HOSPITAL
Unit No.: 10
SUPPLEMENTAL COMIVIITMENT
(Continur,d)
UNPAID: $ 7,910.74
AFFECTS: PARCEL B
ro THE FOLLOWING PARAGRAPH(S) HAS (HAVE) BEEN ADDED TO OUR COMMITMENT:
rr PARAGRAPH NUMBER 85:
off 10. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS:
GENERAL & SPECIAL TAXES:
AFFECTS: SPECIAL TAXES FOR LOT 7
rp PARAGRAPH NUMBER 86:
2006
750451-0080-07
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 1.68
PAID: $ 0.00
UNPAID: $ 1.68
ao 11. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
rR
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS:
GENERAL & SPECIAL TAXES:
AFFECTS: SPECIAL TAXES FOR LOT 9
PARAGRAPH NUMBER 87:
2006
750451-0100-03
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 3.00
PAID: $ 0.00
UNPAID: $ 3.00
SUPLC0Mz/RnA/0M
CHICAGO TITLE INSURANCE COMPANY
Order No.:
Your No.:
Unit No.:
SUPPLEMENTAL COMMITMENT
(Contiaued)
1153726
ST. FRANCIS HOSPITAL
10
OF 12. GENERAL AND SPECIAL TAXES AND CHARGES, PAYABLE FEBRUARY 15, DELINQUENT IF
FIRST HALF UNPAID ON MAY 1, SECOND HALF DELINQUENT IF UNPAID ON NOVEMBER 1
OF THE TAX YEAR (AMOUNTS DO NOT INCLUDE INTEREST AND PENALTIES):
ac
YEAR:
TAX ACCOUNT NUMBER:
LEVY CODE:
ASSESSED VALUE -LAND:
ASSESSED VALUE -IMPROVEMENTS:
GENERAL & SPECIAL TAXES:
2006
750451-0110-01
1205
$ NOT AVAILABLE
$ NOT AVAILABLE
BILLED: $ 3.00
PAID: $ 0.00
UNPAID: $ 3.00
AFFECTS: SPECIAL TAXES FOR TRACT Z
THERE HAS BEEN NO CHANGE IN THIS COMMITMENT SINCE JANUARY 3, 2005, EXCEPT AS SHOWN
HEREIN ABOVE AND ON SUPPLEMENTAL(S) 1.
w
APRIL 7, 2006 AUTHORIZED BY: MIKE HARRIS
sVeiC0bl2lR.UAI0M
CITY OF FEDERAL WAY
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL
DATE: March 13, 2006
TO: Will Appleton, Development Services Manager
Scott Sproul, Assistant Building Official
Brian Asbury, Lakehaven Utility District
Greg Brozek, Federal Way Fire Department
FROM:
FOR DR MTG. ON. -
FILE NUMBER(s):
RELATED FILE NOS.:
PROJECT NAME
PROJECT ADDRESS
ZONING DISTRICT:
Deb Barker
March 30, 2006
06-101077-00-UP
05-105889-PC (Preapplication conference for ICU/PCU Expansion)
St. Francis Hospital ICU/PCU Central Plant Expansion & Loading Dock Relocation
34515 — 9 h Avenue South
[@A
PROJECT DESCRIPTION: Proposed relocation of loading dock near the existing hospital loading dock to
accomate future ICU/PCU expansion and compactor. Also construction of new
1,040 SF electrical switch gear room to accomoadate new generator along with
new air cooled chiller, both in Central plant area on northwest side of building.
LAND USE PERMITS:
PROJECT CONTACT:
Process I
Hammes Company
Doug Garner
1325 4th Avenue, Suite 1035
Seattle, WA 98101
(206) 464-4200
MATERIALS SUBMITTED: Site plan, elevations, materials sheet, undated Detailed Narrative Description
St. Francis Hospital — Loading Dock Remodel / Central Plant Expansion
Process I Detailed Narrative Description
New construction for St. Francis Hospital will include the relocation of the existing
loading dock and the expansion of the existing central plant.
The existing truck ramp will be removed. The new ramp will have the same
configuration as the existing with 2 truck spaces and 1 trash compactor space but will
shift to the north. This shift to the north will free up space along the north wall of the
existing hospital for future hospital expansion.
The existing loading dock, which is currently covered, will remain whole and the new
dock will be added to this existing dock. The new dock will be covered by a structural
steel framed canopy. The canopy will have a built-up roof, metal siding fascia, and
weather resistant soffit. The color of the fascia will match the dark colored EIFS of the
existing hospital
New construction will also include an addition and remodel to the existing central plant. pa O
Additions inside the existing building will include a new boiler and (2) new cold w
pumps. In the plant yard on the north side of the building an above ground fuel ig and
air cooled chiller will be added. Also in this yard will be a new generator and switchgear
building.
This building will measure roughly 40'L x 23'W x 17'H. It will be constructed with split
faced CMU walls with louvers as required by the electrical equipment inside. The steel
frame roof with metal deck will be covered with a standing seam metal roof. The split
face CMU will match the color of the Outpatient Center building on campus and the
standing seam metal roof will match the light color EIFS of the existing hospital.
RECEIVED
MAR 0 7 2006
CITY OF FEDERAL WAY
BUILDING DEPT.
FCITY
ederal Way
RECEIVED MASTER LAND USE APPLICATION
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8'h Avenue South
MAR 0 7 2006 PO Box 9718
Federal Way WA 98063-9718
CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609
BUILDING DEPT. m.w; v,- L yuffedcrulway_cuul
APPLICATION NO(S) —f L2 S Date
3l7/Oz--
ProjectName T... �+ c s f4ca-5 i- i TAL L-1 f PG v
Property Address/Location _y��- S!� [� r,.-�� �� F��� $�• �'
Parcel Numbers) 75 ~- o O Z O
Project Description % h ] ;: 2 -2 e_-& z: 1-2���
'LLB A,E
Type of Permit Required
Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
Land Surface Modification
Lot Line Elimination
Preapplication Conference
Process I (Director=s Approval)
Process II (Site Plan Review)
Process III (Project Approval)
Process IV (Hearing Examiner's Decision)
Process V (Quasi -Judicial Rezone)
Process VI
SEPA w/Project
SEPA Only
Shoreline: Variance/Conditional Use
Short Subdivision
Subdivision
Variance: Commercial/Residential
Required Information
P Zoning Designation
Comprehensive Plan Designation
6 O tj Value of Existing Improvements
Value of Proposed Improvements
International Building Code (IBC):
T -2 Occupancy Type
f[r-TJConstruction Type
Applicant
Name:
Address:
City/State:
Zip:
Phone:
Fax:
Email:
Signature:
Agent (if,
Name:
Address:
City/State:
Zip:
Phone:
Fax:
Email:
Signature:
Douglas Garner
1325 Fourth Avenue, Suite 1035, Seattle, Washington 98101
Tel 206 464 4200 Facsimile 206 464 4201 Cell 206 3213251
E-mail: dgarner@hammesco.com
Name: 1= R A v-aG G ,5 c.fA h1 &4iE74i_-%-w '.57>r6z�'t'
Address: l-117 So u i'�-1 .1 5 c-7L� t-=-7`
City/State: _FW c-c a -z N c-J Pt
Zip: 1:t54-0S-4�33
Phone: ZS-3/426-4/o(
Email: RECEIVE[)
Signature:
Cny
Bulletin #003 -August 18, 2004
Page 1 of 1
Use Application
4111kk� I
CITY
4�'f
Federalo, Way
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
33325 8's Avenue South
PO Box 9718
Federal Way WA 98063-9718
253-835-2607; Fax 253-835-2609
www.citvoffederalway.com
DEVELOPMENT REQUIREMENTS FOR PROCESS I
Director's Approval
Project Name: �ct� c CF14
Project Description: n •��� - .r t� ke Z =fie P,7rr c, A44riD
Applicant/Agenf- I( , ,c
File No(s): (0 — t U (() 7 T LA Y
• This form is to be used by an applicant as a guide in determining what constitutes a complete
application for Process I, Directors Approval.
• All checked items must be submitted to constitute a complete application.
• Process I applications that contain all checked items will be determined complete at intake.
The applicant or agent will be notified immediately if an application is considered complete.
■ A complete application does not imply compliance or conformance with applicable codes.
COMPLETE APPLICATION DATE:
— 0 (0
How To APPLY
The applicant (owner, or owner's appointed agent) must file the following items:
D—,.:.,-A Q„1,—;ftati
❑
A. Master Land Use Application
[�
❑
B. A detailed narrative description of the project, on a separate 8t/2 x 11 sheet
[�
❑
C. Eight copies of the site plan
I�
❑
D. Submittal Fee
If the project involves a new structure or changes to the exterior of an existing structure, also provide:
I7—;rAd .Cnhmiftati
C�
❑
E. Eight copies of existing and proposed building elevations
❑
F. Color & materials indicators (color photos or color board and materials sample)
Bulletin #053 — August 19, 2004 Page 1 of 2 k:\Iandouts\Process I Development Requirements
WHEN USE PROCESS I IS USED
Reference to Process I is found in various places in the FWCC, indicating that certain development,
activities, uses, or interpretations are permitted only if approved using Process I. Any Process I application
that is not exempt from the requirements of the State Environmental Policy Act (SEPA) will be reviewed
using the procedural requirements of Process III. See Federal Way City Code (FWCC) Chapter 22, Article
IV-B, for a detailed explanation of Process I.
WHO MAKES THE DECISION
Under Process I, the Director of Community Development Services makes the decision based on review
and analysis of decisional criteria and the official file. See FWCC Section 22-351 for decisional criteria.
APPEALS
Any decision issued by the director can be appealed. Appeals of Process I, Director's Decision, are decided
by the City of Federal Way Hearing Examiner after a public hearing. See FWCC Section 22-356 for
detailed information regarding appeals of Process I decisions.
STAFF USE ONLY FOR PROCESS I APPLICATIONS
Please consider this as a Notice of Completeness.
As of , 200_, this Process I application is determined to be
complete based on the minimum submittal requirements.
Review of the project will begin upon application assignment. The City of Federal Way will
take action on the application upon the determination that all applicable requirements are
met. Please note that City review will be halted at any time City staff requests additional
information.
Signed:
Title:
THIS FORM SHALL ACCOMPANY THE LAND USE APPLICATION. A COPY OF THIS NOTICE SHALL BE
PROVIDED TO THE APPLICANT OR AGENT FOR THE APPLICATION.
Bulletin #053 — August 19, 2004 Page 2 of 2 k:\Handouts\Process I Development Requirements
Facsia Metal Panel on Loading Dock Canopy
(To match the darker colored existing EIFS)
Existing Colors @ Loading Dock
(Match Colors for New Construction)
Standing Seam Metal Roof @ Generator Building
(To'match the lighter colored existing EIFS)
CMU Split -faced Block @ Generator Building
(To match color of block @ Outpatient Center)
Loading Dock Canopy Materials Generator Building Materials
Design concept of the new canopy at the loading dock and new generator building is to match the color
and materials of the existing hospital. Use of simple forms and straight forward materials.
This is a support area and the attempt is to not draw additional attention to the area, a blended match
will be achieved. A modification to the original materials is to use a flat metal siding at the canopy fas-
cia rather than EIFS. RECEIVE:
St Francis Hospital Loading Dock & Generator Bldg a 7 200
March CAT'fZUOSEDI�fiAL WAY
Phase 1: Central Plant Expansion 6UILDINoDEPT,