Loading...
05-100495 RECEIVED Bv COMMUNITY DEVELOPMEN 'ARTMENT AUG 0 7 2007 4 LAKEHAVEN UTILITY DISTRICT ¢Q 31627-1st Avenue South • P.O.Box 4249 • Federal Way,Washington 98063-4249 �T�I1'Y DIS Federal Way:253-941-1516 • Tacoma:253-927-2922 wwwlakehaven.org August 7 ,2007 Sorath Meng 4213 Southcenter Blvd#22 Tukwila, Washington 98188 RE: Meng Short Plat Reapplication Agreement No. 6206001 Mr>Meng: • The District has received all closing documentation and has completed a satisfactory final inspection of the referenced project for compliance with Lakehaven Utility District standards for materials and construction of sewer systems. Lakehaven hereby initially accepts this project for ownership, operation and maintenance. The Maintenance Bond (No. SG 6003) submitted for the project in the amount of $12,000.00, shall be maintained in force for a period of two years from this date of initial acceptance and until the District gives written notice of its release, pending satisfactory results of a final inspection to ensure the systems remain in compliance with Lakehaven's standards for materials and construction. The Restoration Bond(No. SG 6003) held to guarantee restoration of affected rights-of-way and/or off-site easements is hereby satisfied and may now be released. The bond was issued by CBIC in the amount of $4,000.00. A copy of this letter should be sufficient authorization to the surety to effect its release. The District has reviewed the project account and has estimated the anticipated expenses needed to complete the project through the two-year warranty period. If the actual costs exceed the amount held on deposit following completion of the two-year warranty period, you will be invoiced accordingly. The invoice must be paid prior to release of the Maintenance Bond. Any funds remaining in the account will be refunded following the satisfactory completion of the two-year warranty period, as evidenced by a successful inspection of the systems by District personnel, at which point the project will be granted final acceptance by Lakehaven. Charles Gibson Donald L.P.Miller Ronald E.Nowicki Ed Stewart Beverly J.Tweddle Commissioner Commissioner Commissioner Commissioner Commissioner ,, '• Sorath Meng August 7, 2007 Page 2 Please do not hesitate to call John Jensen, if you have any questions. John may be reached by phone at (253) 946-5406, by electronic mail at jjensen@lakehaven.org, or by fax at(253) 529-4081. Sincer ly, John . Bowman, P.E. Engin eying Manager JCB/JAJ c: City of FW ec: Inspection Finance Field Ops. Ahh, CITY OF CITY HALL Federaay - -- -- - - 33325 8th Avenue South•PO Box 9718 Federal Way, 9806 PO (253)835-7000 wwwcityoffederalway.com q 2-13 March 10, 2005 Mr.Mark Plog, P.E., P.L.S. GeoDatum, Inc. 24829 SE 38th Street Issaquah, WA 98029 Re: Permit#05-100495-000-00-EN;MENG SHORT PLAT 3400 SW 34411'Street Dear Mr. Nog, The Public Works Department has reviewed the engineering plans for the street and storm drainage improvements associated with the above-referenced project. Prior to approval of these plans, the following items must be addressed: All Sheets: Add the engineering(EN)approval number(noted above)just above the approval block. Sheet 1: 1) The drawing index indicates there are five sheets included in the plan set. Please remove this reference,or update the sheet name, if additional sheets are added. 2) Provide approximate cut and fill earthwork quantities required for the street improvements. Sheet 2: Remove the Filter Fabric CB Protection portion from detail 1. The City allows only the CB inserts for use in public right-of-way. Sheet 3: 1) Provide a street cross-section detail for each of 34th Avenue SW and SW 342nd Street. The sections shall include, but not be limited to, all existing and proposed improvements (including pavement widths, planter strips, sidewalks, etc.), existing and proposed rights-of-way/property lines, all existing and proposed horizontal dimensions, and proposed pavement and subgrade thicknesses. (For your information, the pavement/subgrade thickness is: 3 inches CL B A.C. paving,2 inches C.S.T.C.,and 5 inches C.S.B.C.). • 2) A City standard barricade is required at the east end of SW 342nd Street. Show the barricade on the plan view,and provide a detail.(City Standard drawing 3-15). Mark Plog,P.E.,P.L.S. GeoDatum,Inc. Re: Permit#05-100495-000-00-EN;MENG Short Plat Page 2 3) A sign must be attached to the barricade for notification purposes that the road is planned for future extension. Please see the attached for further sign information. 4) The plans indicate `existing' and 'new' street crown locations on 34`"Avenue SW. However, the paving plan only indicates new paving being constructed from the existing east edge of pavement. Please provide additional information as necessary. (This comment may be immaterial, based on comment#5, under the heading`Other', below.) Sheet 4: 1) Provide individual roof drain downspout stub-outs from the storm system to each lot. This system must be connected to catch basins. Provide the pipe size, type and slope, and include lot stub invert elevations. 2) Number each new catch basin,and provide catch basin type. 3) All new catch basins, unless otherwise noted, must be provided with vaned grates. Please indicate this on the plans. 4) It appears the new catch basin, located in the gutterline, at the southeast corner of 34th Avenue SW and SW 342nd Street,should be configured as a`through-curb' inlet,based on it being located near the sag point of the vertical curve. Please revise, or provide information supporting a standard catch basin frame at this location. Other: 1) Provide a Technical Information Report (T.I.R.) for the project. Please call or e-mail to discuss the information required as part of the T.I.R. 2) Add City Standard detail drawings 3-12 (sidewalks) and 3-6 (residential driveways) to the plan set. 3) SW 342nd Street dedication shall be 32-feet, to accommodate the required three-foot utility strip behind sidewalk. Revise the plans to show this. This shall also be revised on the Short Plat documents. 4) Street trees are required within the new planter strips. Utilizing the enclosed City details, show the location and species of each street tree. Include detail 3-29 and 3-33 on the plans. Please note that the street trees must be minimum 2112"caliper. 5) It appears 34th Avenue SW will be open-cut in order to provide water service to the lots, and potentially to provide other dry utilities. If so, 34th Avenue SW is subject to a full-width asphalt overlay. The overlay limits will need to be shown on the plans. Grinding of the existing asphalt is required along the existing concrete gutters, and a butt joint required at the southerly/westerly extent of overlay on SW 343rd Street. The required pavement thickness for the overlay is 1 %2 inches Class A. r Mark Plog,P.E.,P.L.S. GeoDatum,Inc. Re: Permit#05-100495-000-00-EN;MENG Short Plat --- Page 3 6) Bonding is required for all street and storm drainage improvements. Please complete and return the enclosed Bond Quantities Worksheet. Please also provide the applicant with the enclosed Bond Information sheet, for its completion and return to the City. (An Assignment of Funds in Lieu of Bond may be utilized, if preferred.) 7) Please refer to the red-lined plans for additional comments not covered under this letter. 8) Additional items, as requested above, may be added to a separate detail sheet,.or added (and referenced) to existing sheets,as necessary. The City details are available for download from our website at www.cityoffederalway.com. Please submit three (3) copies of the revised engineering plans, and 3 copies of the revised Short Plat drawings. If you have any questions, please call me at (253) 835-2734, or e-mail at kevin.petersonrcityoffederalway.com. Sincerely, Kevin Peterson Engineering Plans Reviewer KP:dl enclosure cc: Jane Gamble,Associate Planner Sarady Long,Traffic Engineer Kathleen Messinger,Street Systems Engineering Technician Project File/KP Day File I:\csdc\docs\save\8349807005.doc