Loading...
19-102758CITY HALL CITY OF 33325 8th Avenue South A4 Federal Way, WA 98003-6325 _ FederalWay (253) 835-7000 Centered on Opportunity www.cityoffederalway..com Jim Ferrell, Mayor November 8, 2019 Mr. Aleksey Onishchenko FILE 36427 10th Court SW , Federal Way, WA 98023 Re: Files: 19-102758-AU;19-102759-SF; & 19-102757-SF DETACHED ACCESSORY DWELLING UNIT APPROVAL 304th and 215t Avenue SW LLC, No Site Address, Federal Way Dear Mr. Onishchenko: The Department of Community Development has completed their review of the enclosed Accessory Dwelling Unit (ADU) application submitted to the city on June 10, 2019. The ADU application is hereby approved pursuant to the findings presented by the department's Planning Division staff and the conclusions based on those findings. FINDINGS OF FACT The following findings are based on site, elevation, and floor plans received with the land use application and resubmitted information received September 20, 2019: 1. Proposal— The applicant proposes to construct a 792 square -foot detached ADU accessory to a 2,418 square -foot two-story single-family residence, located on parcel 0121039163, lot B of Boundary Line Adjustment file number 15-106557-AU, AFN 201609299000. 2. Zoning The lot is 18,516 square -Feet (0.43-acre) within the Single -Family Residential (RS) 15.0 zoning district. The proposal meets the minimum lot size requirement per Federal Way Revised Code (F`vVRC) 19.200.180, Note 1. 3. Lot Coverage —The lot coverage of the principal dwelling, proposed ADU, and driveway is approximately 50 percent of the lot area. The proposal does not exceed the maximum lot coverage of 60 percent in the RS 7.2 zone pursuant to FWRC 19.200.180, Note 2. 4. Floor Plan —The total ADU laving area is 792 square feet. The principal dwelling unit contains 2,418 square feet of livable area; therefore, the proposed ADU complies with the maximum allowable livable area, which is 40 percent of the living area in the primary dwelling unit. The proposal also will not exceed the maximum accessory dwelling unit size of 800 square feet (FWRC 19.200.180, Note 9). Mr. Aleksey Onishchenko Page 2 of 3 November 8, 2019 5. Water dam' Sever— The applicant proposes to serve the ADU with public water and sewer managed by the Lakehaven Water and Sewer District. Lakehaven issued Certificates of Water and Sewer Availability on November 15, 2016, and indicated the proposal will connect to an existing eight -inch sewer main and a 10-inch water main that is located 40 feet from the site. These service connections and meters must be large enough to service the new single-family residence and accessory dwelling unit. 6. Required Yards & Height— The proposed attached ADU and associated improvements must meet the required 20-foot front yard, and five-foot side and rear yard setbacks. 7. Owner Occupancy — The applicant must submit a signed letter of application and deed restriction stating the owner shall occupy one of the two dwelling units as a permanent residence for six months or more per calendar year. CONCLUSIONS The following conclusions are based on the above findings of fact. 1. The proposal is consistent with policies of the Federal Way Co�nprehenrive Plan. 2. The proposal meets density, square footage, parking, occupancy, and dimensional requirements of the ADU Use Zone Chart within FWRC 19.200.180. 3. The ADU is designed to be subordinate and incidental in size, scale, and design of the primary dwelling unit, and the appearance remains that of a single-family residence. CONDITION OF APPROVAL 1. The ADU, excluding garage, workshop, and similar non -living areas, shall contain between 300-800 square feet, but shall not exceed 40 percent of the square feet of the primary dwelling unit, excluding garage, workshop, and similar non -living areas. The unit shall have no more than two bedrooms. 2. Prior to the final building inspection of the new ADU, please record the enclosed Letter of Application & Deed Restriction with the King County Recorder's Office, and return a copy to my attention with the enclosed resubmittal form. BUILDING PERMIT REQUIRED 1. The single-family home and ADU will require a building permit prior to construction. Please contact the Permit Center at 253-835-2607, or permitcenter@cityoffederalway.com, if you have any questions regarding building permits. 2. For additional water and sewer information, please contact Brian Asbury with the Lakehaven Water and Sewer District at 253-946-5407, or basbur�-{c 1akehaven.grg_ 19-102758-00-AU Doc, LD. 79296 Mr. Aleksey Onishchenko Page 3 of 3 November 8, 2019 CLOSING This adrninistrative ADD decision does not waive compliance with future City of Federal Way codes, policies, and standards relating to this development. If you have any questions regarding this decision, please contact Associate Planner Natalie Kamieniecki at 253-835-2638, or natalie.kamieniecl:i citvoffederalwa'.com. Sincerely, 1 x Davis Community Development Director enc: Letter of Application & Deed Restriction Resubmittal Form Natalie Kamieniecki, Associate Planner Doc, I.D. 79296 19-102758-00-AU u,+ DEPARTMENT OF COMMUNITY DEVELOPMENT C ^ C I"� ry 33325 81h Avenue South Z 4L Vi � RECEIVED C V V Federal Way, WA 98003 253-835-2607;Fax 253-835-2609 CITY OF Federal Way JUN 10 2019 �y�v%v.cityaffederalNvay.com TY OF FEDERAL WAY COMMUNITY DEVELOPMENT ACCESSORY DWELLING UNIT (ADU) FEE: Contact the Permit Center at 253-835-2607, or ermitcente ¢i offederalwa .com _ FILE # Owner's Name: ESQ Address: — o RELATED FILE #5: i " — ! 0 � A.,S L C4Q/7l60 Daytime Phone: 253 2l'7 - 96 gC R,5 Zoning: ! 15"ti V Lot Size in Square Feet: _ /A 16 Fed l k 44 99 01 Tax Parcel#: 01 0-3, 9 / 0 Type of ADU: ❑ Attached t$fDetached Is this a: )� New ADU ❑ Existing ADU Existing ADU was: ❑ Approved by King County (Provide a copy of the permit.) ❑ Other Construction of existing ADU completed in 19�/20^ Construction of existing residence completed in 19 /20— Which is the owner occupied unit: ❑ Primary Dwelling Unit or ❑ ADU Number of square feet: Z IS Primary Dwelling Unit 71 .)- ADU Provide the following information: Lakehaven Utility District Water & Sewer Certificates of Approval for the New ADU ❑ King County Public Health Department Approval (if septic) ❑ Heating Type: P Electric ❑ Gas ❑ Other ❑ Electrical Capacity: 7010 6 Primary Dwelling Unit 100 F} ADU ❑ Letter of Application & Deed Restriction (attach) ADU FLOOR PLAN DRAWINGS (Provide the following; refer to page 3 for an example.) ❑ Floor plan of the primary dwelling unit and the ADUX CY'fiumbing (existing & proposed) W-Mechanical - HeatingNentilation/Air Conditioning (existing & proposed) 8' Entrances of primary dwelling unit and ADU (existing & proposed) Su- M'vj Ceiling Heights/Room Sizes for ADU nn ❑ Elevation of the proposed ADU with the primary dwelling unit N//4 Bulletin #049 — December 21, 2015 Page I of 3 k:\Handouts\ADU Application /DUSITE PLAN DRAWINGS (Provide the following; refer to page 3 for an example.) ❑ Scale/north arrow ❑ Street/driveway location ❑ Lot dimensions ❑ Primary dwelling unit ❑ ADU footprint (if detached) ❑ Building setbacks from property line ❑ Location of utilities & easements ❑ Show location of three on -site parking stalls ❑ Locate the entrance of the primary dwelling unit and the ADU ❑ Calculate the total impervious surfaces coverage for the site (Include the existing and proposed roof area, driveway, patios, and walkways.) ❑ Other 1 DISCLAIMER: I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge and fuither, that I am authorized by the owner of the above premises to perform the work for which the permit application is made. Signature of Applicant (0 /N / lq Date WAIVER: Approval of the ADU Land Use Application does not constitute approval of the building permit. Application and approval of the buildingpermit is a separate process. OFFICE USE ONLY ❑ ADU Status: ❑ Legal Nonconforming per FWRC 19.30.140 ❑ New ADU ❑ Assigned Address of ADU ❑ Deed Restriction/Letter of Application Rec'd ❑ Recording Number ❑ Other Approved by p Conditions of Approval Date Bulletin #049 — December 21, 2015 Page 2 of 3 k:\Handouts\ADU Application 41k CITY 10';:tS;P OF Federal Way October 7, 2019 Aleksey Onishchenko 3647 1 Oth Ct. SW Federal Way, WA 98023 Department of Community Development 33325 8th Avenue South Federal Way, WA 98003 253-835-2601 — Fax: 253-835-2609 www.ci offederalwa .cam RE: ADU on parcels 012103-9099 and 10203-9163 per Building Permits 19-102755 and 19- 102758 Mr. Onishchenko; Per your letter to me on October 1, 2019 and your request to exempt ADUs from school impact fees, I regret that we cannot do so at this time regardless that no children will live in the units. FWRC 19.95.060 originally exempted ADU for a one-year period between 1995 and 1996. The "time clause ("December 21, 1995, and terminating on December 20, 1996") still exists within the Code and we are obligated to enforce that. We are, at this time, in the process of examining this requirement and potentially removing the clause. I am sorry that I cannot provide any more relief from this obligation at this time, but the Code will not allow it. Please call with any questions. Sincerely; 1 / lob4ert"Doc" Hansen Planning Manager 253-835-2643 Aleksey Onishchenko 36427 10th Ct SW Federal Way, WA 98023 October 1, 2019 To: Robert "Doc" Hansen Request to Waive school impact fees for ADU (Lot B). Permit No: 19 102758 00 AU I would like to request the City of Federal Way to waive the school impact fee on the ADU. The ADU will not be occupied with children at any time. The family will live in the main house under the permit number 19 102757 00 SF (where the school impact fees will be paid). Sincerely // �X- � Rleksey Onishchenko DEPARTMENT OF COMMUNITY DEVELOPMENT 33325 81h Avenue South CITY OF �' Federal Way, WA 98003-6325 Fed a rn I Min 253-835-2607; Fax 253-835-2609 www.cirvoOfcdera])Kay.com CALCULATING TREE UNITS This form can be used to demonstrate how you will meet the minimum tree unit requirement for your site and should accompany your submittal. Trees to be retained or planted must also be shown on your submitted site plan, or a separate tree plan. 1%516 (lot size in square feet) 43,560 (sf/acre) = , y2 x 25 (units/acre) _ f� l i (lot size in acres) (minimum tree units) Existing Trees Includes all trees except invasive species and hazard trees Tree Size (diameter at breast height /4.5') # of Trees Tree Units to Remain 1" to 6" dbh x 1.0 = > 6" to 12" dbh x 1.5 = > 12" to 18" dbh x 2.0 — > 18" to 24" dbh x 2.5 = > 24" dbh x 3.0 = Total Existing Tree Units to Remain Total Units Replacement/Additional Trees Evergreen Trees — minimum 6' in height at planting Deciduous Trees — minimum 2" caliper at planting Large Canopy = 1.5 Tree Units Medium Canopy = 1 Tree Unit Small Canopy = .5 Tree Units Tree Species Canopy Tree # of Trees Total Units (Sm/Med/Lg) Units Total Proposed Tree Units to be Added Total Existing and Proposed Tree Units Bulletin #073 —June 8, 2016 Page 1 of 1 k:\Handouts\Calculating Tree Units