14-102712CITY OF
Federal
June 24, 2014
Ronald Meckler
Crown Castle
8432 154`h Avenue
Redmond, WA 98052
CITY HALL FILE
�� 33325 8th Avenue South
Federal Way, WA 98003-5325
(253) 835-7000
www. cityoffederalway, com
RE: Permit #14.102712-00-UP; SPRINT SE63XC320
2920518"' Avenue South, Federal Way
Dear Mr. Meckler:
The City of Federal Way's Community Development department has completed use review of the proposed upgrades and additions to an existing Personan administrative land
al Wireless Service Facility
(PWSF) owned by Puget Sound Energy and operated by Sprint Spectrum LLC at 29205 18t' Avenue
South, Federal Way, WA 98003. The proposal includes adding three antennas to the existing array with
remote radio head (RRM units, Filters, and junction cylinders. The height of the existing tower will not be
increased, nor will the footprint of the existing equipment compound.
The Process I application was submitted and determined to be complete on June 10, 2014. Your proposal
is found to be consistent with provisions of Federal Wiry Revised Code (FWRC) Chapter 19.55, `Process
I —Director's Approval,' and Chapter 19.255, `Personal Wireless Service Facilities., Your Process I
proposal is hereby approved.
The Process I land use approval is supported by the following statements of fact:
I. Zoning & Land Use —The zoning designation for the subject property (BC)
(
mmunity Bu
is Cosiness
zone. PWSFs are permitted in BC zones pursuant to the zoning chart found o FWRC 19. siness
2. Review Process — According to submitted materials, the applicant proposes adding three antennas,
three RRH's, three filters, and six junction cylinders to the existing array. e No height increase is
proposed. The addition of new antennas on an existing PWSF is subject to Process I Director's
Approval pursuant to FWRC 19.15.030 `Review processes for improvements and additions to
developed sites.'
3. Prioritized Locations — Applicant proposes PWSF improvements in "existing broadcast, relay, and
transmission towers" or the second prioritized location set forth in FWRC 19.255.010(4). The highest
prioritized location is not feasible as this proposal is an upgrade to an existing facility. Staff fads the
applicant has met the burden to utilize the second prioritized Iocation. The addition of three antennas
should provide the full benefit of service to the area.
4. Cumulative Effects —The City must consider the cumulative visual effects of PWSFs mounted on
existing structures and/or located on a given permitted site in determining whether additional perm its
may be granted so as to not adversely affect the visual character of the City. As shown t the site plan
Mr. Meckler
June 24, 2014
Page 2
the equipment
and elevations, the addition of new antennas and
vallinotions adve�sely affect the visual character of the
ound are not a
substantial increase to the existing site. The P
City and there is no proposed height increase.
er
5. Facilities — The proposed facility exceeds microcell and e iFoWRCilitY t r sholds for
th fanner of
antennas defined in FWRC 19-05.130, `M definitions
exceeding such thresholds may be permitted i A adverse
$tC) the numberf antennas aand �their size
equipment cabinets meet adopted development
are appropriate for the location, surrounding enviro of the FWRC Thep proposal ispotential visual scon ssteent with
PWSF shall comply with all other applicable standards
this code section.
in three I�ftH's, three filters, and six Ju ction t enclosure area. Proposed upgrades will occur
ers
6. Exempt Activity —Applicant proposes c►tr
on an existing monopole structure
whin no exteriothe r Therefore, these changes are exempt
ti
within the existing fenced area resulting itted outright with no further
from PWSF standards set forth in FWRC Chapter 19.255 and are perm
zoning compliance required pursuant to FWRC 19.255.010(3)(9)
7. State Environmental Policy Act (SEPA) — The proposed improvements are exempt from State
Environmental Policy Act review as the scope of work
al of equipment for eplatcementt of existing
800(25)(a)(i): the collocation of new equipment, e the physical
equipment on existing or replacement structures that does not substantially Chang p y
diYnerlSlQr1S of 511C11 structures.
eet Process 1 purpose criteria set forth in
8. Process I Thresholds — The proposed improvements m
FWRC 19 55.020 and 19.15.030; including compliancea with applicable provisions of FWRC Title 19
`Zoning and Development' and health, safety, and
PEkmff issuANu, REQuIRED
Prior to any site work, the applicant shall obtain a building and electrical permit fromplease contact Building
Department. For further informationtcegarding offend lg r.el or2 3�835 26 7.
department's pertriit center at
CLOSINGWay codes, policis, d
standards
This decision shall not waive compliance with futureCity ofdemo al of a building ore
electrical permit.relating to this site. This Process I approval does n
ot constitute The effective date of this decision is June 27, 2014, or three days from the date of this letter. Pursuant to
The
1give date
any person who received notice of this administrative decision may appeal the decision
Examiner by July 8, 2014. Any appeal must be in the form of a letter
to the Federal Way Hearing
t tt
delivered to the Department of Community Developmentand a y-tatetnentestablished
the alleged errors in the er mus
contain a clear reference to the matter being appealed
Director's decision. No work on the proposal can commence until the end of the appeal period.
In that you are the only party of record, your appeal period is waived (assuming you do not wish to appeal
this decision). Waiver of the right to appeal does not affect the effective date of this decision. Work on the
site may not commence until you have been issued the appropriate building and electrical permit.
Doc I D 65824
14-102712
Mr. Meckler
June 24, 2014
Page 3
This Process I approval is valid for one year from the effective date of this decision. If no further action is
taken within one year, this decision will expire. A one-year extension of time may be granted only if a
written request is submitted to the City's Department of Community Development at least 30 days prior
to the expiration of the decision.
If you have any questions regarding this decision, please contact Planning Intern Kalon Thomas at 253-
835-2622 or kalon.thomas cQci!yof ederalway.com.
Sincerely,
Isaac Conlen
Planning Division Manager
for Patrick Doherty, Director
enc: Approved Site Plan
c: Kalon Thomas, Planning Intern
14-102712 Doc. I.D. 65824
R.2NO MASTER LAND USE APPLICATION
DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES
J U N 10 2014 33325 8'' Avenue South
CITY OF � Federal Way, WA 98003-6325
Federal Way CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609
CDS 11111E'.CEt�'UlledLCnlllal'.Ctln1
0(D �
APPLICATION NO(S) 102 712 -cc) UPI Date
& /I ()/(+
Project Name Sprint 2.5 SE63XC320 JEFFRIES 880427
Property Address/Location 29201�, 18TH AVENUE, SOUTH, FEDERAL WAY, WA 98003
Parcel Number(s) 304020 065
Project Description Cell site modification — Instal.1 three (3) panel ante as three Q remote radio head_(RRH) units six 6
'unction cylindem and three 3 filters on the existing tower.
'LEASE
Type of Permit Required
Annexation
Binding Site Plan
Boundary Line Adjustment
Comp Plan/Rezone
Land Surface Modification
Lot Line Elimination
Preapplication Conference
Process I (Director's Approval)
Process II (Site Plan Review)
Process III (Project Approval)
Process IV (Hearing Examiner's Decision)
Process V (Quasi -Judicial Rezone)
Process VI
SEPA .w/Project
SEPA Only
Shoreline: Variance, -Conditional Use
Short Subdivision
Subdivision
Variance: CommercialfResidential
Required Information
BC Zoning Designation
Comprehensive Plan Designation
$500.000 Value of Existing
Improvements
$20,000 Value of Proposed
Improvements
International Building Code (IBC):
U Occupancy Type
Applicant
Name:
Sprint Spectrum LLC
Address:
10545 Willows Rd NE, Suite 200
City/State:
Redmond, WA
Zip:
98052
Phone:
206-427-5856
Fax:
Email:
Kevin.Foy@Sprint.com
Signature:
Agent (if different than Applicant)
Name:
Ronald Meckler, Contractor, Crown Castle USA
Address:
8432 150 Ave NE, Building C
City./State:
Redmond, WA
Zip:
98052
Phone:
425-202-0203
Fax:
Email:
Konald.Meckler@Comeast.net
Signature:
[I�y
Name: Russell R Lloyd
Address: P. O. Box 4203
City/State: Federal Way
Zip:
Phone:
Fax:
Email
Signature: See attached Letter of Authorization
Bulletin #003 —January 1, 2011 Page I of l kMandoutsNaster Land Use Application
61 YL
DATE: May 23, 2014
Crown Castle Tel: 425-202-0203
Ron Meckler Mobile: 206-384-2454
8432 154th Avenue NE Fax: 425-202-2771
Redmond, WA 98052 Ronald.Meckler@crowncastle.com
TO: City of Federal Way, WA
Department of Planning and Environmental Regulation
FROM: Ron Meckler, Real Estate Specialist
Crown Castle
On behalf of Sprint Spectrum LLC
RE: Type I Land Use and Zoning Application
Sprint 2.5 Project
Site SE63XC320 JEFFRIES 880427
29205 18T" Ave S, Federal Way, WA 98003
My name is Ron Meckler and I am a contractor for Crown Castle for zoning and permitting services. Our
client, Sprint Spectrum, is in the process of a national update and modernization of its wireless
service. The project requires adding antennas to their existing array, adding remote radio units behind
the antennas, and installing filters and junction cylinders on the existing hybrid cables..
Purpose of Request
The project requires swapping out their existing antennas for new antennas, as well as updating cabinets
and associated cabling at all of their existing wireless facility sites. An earlier phase of the project known
as' Network Vision was completed last year when the new equipment cabinets were installed along with
cables and some of the new antennas. This phase will add three more antennas with remote radio head
(RRH) units, filters and junction cylinders. THE HEIGHT OF THE EXISTING TOWER WILL NOT BE
INCREASED, NOR WILL THE FOOTPRINT OF THE EXISTING EQUIPMENT COMPOUND
Process I Review
1. Zoning & Land Use — This is an existing 93' monopole support structure, located in a
Community Business (BC) zone. Sprint is proposing to make the following improvements, as
depicted in the attached Site Plan/Elevations. Sprint will be installing 3 antennas, 3 RRH's, 3
filters and 6 junction cylinders to their existing antenna array.
2. Review Process — Sprint is requesting a Type I Director's Review for improvements and
additions to developed sites.
3. Prioritized Locations — This is a priority 2 location, which is an upgrade to an existing facility.
4. Cumulative Effects -- The existing WCF does not contribute to any increase in vehicular traffic
in the area, does not require any water, or solid waste services. There are no negatives to the
existence of this WCF operating at the current location. There will be no significant increase to
the visual impact of the site. The new antennas are of similar size and shape and color of the
existing antennas. There are no changes to the ground equipment configuration, arino work is
proposed on the equipment cabinets.
5. Facility — The proposed modification will not and new or adverse visual impact. No new MrA
cabinets are proposed. The quantity of antennas is appropriate for the location and surrou#f
ng-
environment, which is commercial in nature.
JUN 10 2014
CITY OF FEDERAL WAY
CDS
6. Exempt Activity — No changes to the ground equipment configuration are proposed. No work
is proposed on the existing cabinets.
7. SEPA — The proposed improvements are exempt from the State Environmental Policy Act. The
antennas are attached to an existing structure in a commercial zone that does not contain a
school or residence.
8. Process I Thresholds — The proposed improvements are minor in nature and should meet the
Process I purpose criteria.
Please do not hesitate to contact me for any additional information or clarification
Sincerely,
Ronald Meckler
Crown Castle USA
8432 154th Ave NE
Redmond, WA 98052
Tel: 425-202-0203
Email: Ronald.Meckler@cr vncastle.com
Enclosures: Master Land Use Application
Process I Application
King County Assessors parcel map
Vicinity Map
Site photograph & simulation
Permitting Authority
Construction Drawings (6) 11x17
Check for fees
PU3"T
SDUND
ENERGY
PERMIT FOR LOCATION OF FACILITIES
SPRINT SPECTRUM — MARINE VIER' SUBSTATION — PSE - #SE63XC320
This Permit, dated as of MV -L G _ , 2004, is made by
and between Puget Sound Energy, a Washington corporation ["PSE"), and Sprint Spectrum
L.P., a Delaware limited partnership ("Sprint Spectrum"). PSE and Sprint Spectrum are at
times referred to herein where appropriate individually as a "Party" and collectively as the
"Parties". The Parties agree as follows:
1. Permit. For and in consideration of the mutual benefits to be derived
therefrom, PSE hereby grants permission to Sprint Spectrum, subject to the terms and
conditions of this Permit, to use the real property described in the attached Appendix 1 (the
"Site"). The rights and obligations of Sprint Spectrum arising under this Permit will apply to
and be binding upon Sprint Spectrum's officers, employees, agents and representatives, and
its suppliers and subcontractors of any tier acting on behalf of Sprint Spectrum in connection
with the performance of the Work (as defined below) or this Pen -nit (collectively, the
"Support"). Sprint Spectrum shall be solely responsible for the performance,
nonperformance, acts and omissions of its Support.
2. Use of the Site. Sprint Spectrum shall have the right to use the Site for the
purpose of undertaking the following activities (the "Permitted Activities"):
2.1 installation, operation and maintenance of the equipment specified in
the attached Appendix 2 (the "Equipment") in accordance with the site development plan
attached hereto as Appendix 3 (the "Site Development Plan") and all other provisions of this
Permit; and
2.2 performance of the installation, maintenance, repair, relocation,
removal and other work specified in the Site Development Plan (collectively, the "Work") in
accordance with the Site Development Plan and all other provisions of this Permit; and
2.3 obtaining, at Sprint Spectrum's sole cost and expense, telephone
service from any utility company that provides such service to the Site, and arranging for the
installation of a separate meter and main breaker, subject to PSE's right to approve the exact
location of proposed utility routes and the manner of installation; and
2.4 access to and from the Site for purposes of undertaking the activities : -
specified in paragraphs 2.1, 2.2 and 2.3, in accordance with the following:
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA.I23) Page 1
2.4.1 access for construction, routine maintenance and repair and
other non -emergency visits shall only be during normal business hours (defined as
Monday through Friday, 8 am to 6 pm) unless otherwise agreed upon by the Parties;
2.4.2 in the event of emergency, Sprint Spectrum may access the Site
twenty-four (24) hours per day, seven days per week, by calling the PSE emergency
telephone number set forth in paragraph 7 and requesting such access;
2.4.3 access to the Site may be by foot or motor vehicle, including
trucks; and
2.4.4 access to the Site shall be subject to such reasonable conditions
as may be imposed by PSE from time to time.
3. Limitations on Use. Except and only as specifically authorized in
paragraph 2, Sprint Spectrum shall not enter upon the Site or make any use thereof. Without
limiting the generality of the foregoing:
3.1 Sprint Spectrum shall, at all times, undertake the Permitted Activities
in a manner so as to prevent bodily harm to persons (whomsoever) and damage to property
(whatsoever). Precautionary measures shall include, without Iimitation, reasonable site
security measures (e.g., fencing, signage, lighting, security guards, etc.) necessary to prevent
access to the Site during such times as the Permitted Activities may cause the Site to be in an
unsafe or unsecured condition.
3.2 Sprint Spectrum shall, at all times, undertake the Permitted Activities
in a manner that does not disturb or interfere in any way with the operations of PSE or any
prior existing users of the Site, or otherwise in a manner that would impair the safe,
continuous and reliable operation of PSE's utility systems or improvements. Without limiting
the generality of the foregoing, Sprint Spectrum shall at all times:
3.2.1 conduct the Permitted Activities so as to maintain legal and
safe clearances from PSE's utility systems or improvements;
3.2.2 take all prudent precautions to ensure that no persons or
property come into contact with PSE's utility systems or improvements; and
3.2.3 conduct the Permitted Activities so as to maintain access along
and across the Site to PSE's utility systems and improvements, sufficient to allow the
free passage of all equipment, vehicles, personnel and other items as may be
necessary or convenient for the maintenance, repair and replacement of PSE's utility
systems and improvements.
If, at any time, the Permitted Activities shall disturb, interfere with or otherwise impair the -
safe, continuous and reliable operation of PSE's utility systems or improvements, Sprint
Spectrum shall immediately cease and discontinue such Permitted Activities. If Sprint
Spectrum anticipates that any Permitted Activity may disturb, interfere with or otherwise
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA l23) Page 2
impair the safe, continuous and reliable operation of PSE's utility systems or improvements,
Sprint Spectrum shall request in writing, not less than fourteen (14) days in advance of the
date required, that PSE take such action with respect to its systems or improvements as is
necessary to accommodate such Permitted Activity. PSE may elect to accommodate such
Permitted Activity in response to such request; provided, however: (a) all costs and expenses
incurred by PSE thereby shall be reimbursed to PSE, and (b) PSE may refuse any or all such
requests or may discontinue actions undertaken in response to such requests, as PSE, in its
sole discretion, may choose.
3.3 Sprint Spectrum shall not undertake any activities and shall not use or
permit any use of the Site that will in any way:
3.3.1 be in noncompliance with, or otherwise conflict with, any
applicable laws, regulations, ordinances, rules, orders or other requirements, now or
hereafter in effect, of any governmental authority (all laws, regulations and orders
required to be incorporated in agreements of this character are hereby incorporated
herein by this reference);
3.3.2 cause or constitute any nuisance, noxious odors, unsafe
condition or waste in or about the Site;
3.3.3 interfere with the rights or disturb the use and enjoyment of
PSE, other users of the Site, or any other person lawfully on the Site;
3.3.4 cause a cancellation, increase the premiums for or deductibles
under or otherwise affect any fire, casualty, property, liability or other insurance
covering the Site, any activities conducted upon or from the Site, or any accident, act,
error, omission, fault, negligence or strict liability occurring on or about the Site; or
3.3.5 except as otherwise provided in the Site Development Plan,
cause or allow the generation, storage, processing, handling, transport, spill, disposal
or release of any dangerous, hazardous or extremely hazardous material, waste or
substance at, upon or in any way affecting the Site (including, but not limited to, any
such materials, waste or substances subject to regulation by any federal, state or local
law pertaining to the protection of human health or the environment).
3.4 Sprint Spectrum shall not, and shall not pen -nit others to, install, store,
maintain or operate any equipment, fixtures, improvements, supplies, vehicles or other items
on the Site except for the Equipment (which Equipment shall be installed, maintained and
operated at Sprint Spectrum's sole cost, risk and expense).
3.5 Sprint Spectrum shall obtain and comply (and shall ensure that all of
Sprint Spectrum's Support comply) with all permits, licenses, franchises, rights -of -way,
easements and other rights required to undertake any Permitted Activity. Sprint Spectrum
shall furnish to PSE such evidence thereof as PSE may request.
Sprint Spectrwn SE63XC320
Marine View Substation— PSE (SEA123) Page 3
3.6 If, in PSE's reasonable judgment, the Equipment or any Permitted
Activity violates, jeopardizes or unreasonably interferes with: (a) any laws, regulations,
rules, orders or other regulatory authorizations, permits or approvals that may concern PSE's
present or future use and enjoyment of the Site, or (b) any proprietary rights such as any
contract, permit, license, franchise, right-of-way, easement or other rights of PSE, and Sprint
Spectrum fails to correct the problem within thirty (30) days after written notice from PSE (or
such shorter or (to the extent reasonably necessary to correct the problem) longer period of
time as is expressly required or permitted under the applicable law, regulatory authorization,
permit or approval or applicable proprietary right of PSE), PSE may require that Sprint
Spectrum immediately remove any or all Equipment from and cease any Permitted Activity at
the Site. If Sprint Spectrum fails to remove any Equipment within fifteen (15) days after PSE
makes its request, PSE may remove the Equipment at Sprint Spectrum's sole risk and expense
and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred.
3.7 Sprint Spectrum shall timely pay all (and shall promptly secure the
discharge of any liens asserted by any) persons and entities furnishing labor, equipment,
materials or other items in connection with the Permitted Activities. Sprint Spectrum shall
furnish to PSE such releases of claims and -other documents as may be requested by PSE from
time to time to evidence such payment (and discharge). If any such persons or entities are not
timely paid (or if any of such liens are not promptly discharged), PSE may make such
payments (and secure such discharge) at Sprint Spectrum's expense and Sprint Spectrum shall
reimburse PSE for the entire expense thereby incurred. Sprint Spectrum may contest the
validity of any such lien provided that Sprint Spectrum delivers a bond to PSE in the amount
of the contested lien.
3.8 In undertaking the Permitted Activities, Sprint Spectrum shall comply
and shall ensure that all of its Support comply with all applicable industry standards and
codes, and all of PSE's standard practices, specifications, rules and regulations provided by
PSE to Sprint Spectrum on request. Sprint Spectrum shall furnish such documents as may be
required to effect or evidence such compliance.
3.9 Sprint Spectrum shall comply with the following in connection with its
performance of the Work:
3.9.1 Sprint Spectrum shall furnish all personnel, supervision, labor,
transportation, tools, equipment and materials for performance of the Work. Sprint
Spectrum shall expeditiously and efficiently perform the Work in accordance with the
Site Development Plan and the provisions of this Permit. Sprint Spectrum shall not
independently hire any PSE employee to perform any of the Work (e.g., other than in
the course of his or her employment with PSE with respect to Work that PSE agrees
to perform for Sprint Spectrum).
3.9.2 Sprint Spectrum shall perform the Work in a workmanlike and
skillful manner. Sprint Spectrum shall ensure that the Work and the Equipment is in
all respects (a) safe, (b) of first-class quality, (c) free from all faults and defects in
workmanship, material and design, and (d) in confonnance with such reasonable
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 4
1
requirements and specifications as PSE shall from time to time prescribe and all laws
and the regulations, orders and decrees of all lawfully constituted bodies and tribunals
pertaining to the construction, operation and maintenance, including without
limitation, the requirements of the latest edition of the National Electrical Safety
Code.
3.9.3 Sprint Spectrum shall promptly and satisfactorily correct or
replace any Work or Equipment found to be defective or not in confonnity with the
requirements of this Permit. If Sprint Spectrum fails or refuses to perform any Work
required by this Permit or to make any such corrections or replacements, PSE may
perform such Work and make such corrections and replacements at Sprint Spectrum's
sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense
thereby incurred.
3.9.4 Installation of the Equipment or the performance of other Work
shall not adversely affect the structural integrity, maintenance or marketability of the
Site or any structure or improvement on or surrounding the Site.
3.9.5 Sprint Spectrum shall ensure that all personnel who perform
the Work shall be fully experienced and properly qualified to perform the same.
Sprint Spectrum shall, if so requested by PSE, remove from performance of the Work
any personnel (including, without limitation, any Support) whom PSE finds to be
incompetent, careless or otherwise unsafe.
3.9.6 Sprint Spectrum hereby acknowledges that PSE employs
workers covered by one or more collective bargaining agreements. In the event of any
actual or potential labor dispute between PSE and its workers that is, in whole or in
part, based upon or otherwise arises out of the performance of the Work or this
Permit, Sprint Spectrum will cooperate with PSE and take such action as may be
reasonably requested by PSE to fully and expeditiously resolve such dispute.
3.9.7 Sprint Spectrum shall, at all times, keep the Site cleared of
rubbish, refuse and other debris generated by Sprint Spectrum or its Support and in a
neat, clean and safe condition. Upon completion of any portion of any of the Work,
Sprint Spectrum shall promptly remove all rubbish, refuse and other debris generated
by Sprint Spectrum or its Support and all of its Equipment and surplus materials.
39.8 The Work and the Equipment (i.e., as it relates to the Work)
shall at all times be subject to inspection and testing by PSE. Sprint Spectrum may, at
its option, have a representative present at the Site during any such inspection or
testing by PSE. If, in PSE's reasonable judgment, the performance of any Work
requires one or more representatives of PSE to be present at the Site during the
performance of such Work, then Sprint Spectrum will reimburse PSE for any and all
reasonable costs and expenses thereby incurred by PSE. No inspection, test, delay or
failure to inspect or test, or failure to discover any defect or non-compliance by PSE
shall relieve Sprint Spectrum of any of its obligations under this Permit.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 5
3.9.9 Sprint Spectrum shall promptly settle or resolve all complaints
received by Sprint Spectrum from third Parties arising out of or in connection with
performance of the Work. Sprint Spectrum shall promptly notify PSE of all such
complaints and any action taken (or to be taken) in connection therewith. In handling
any complaints, Sprint Spectrum shall use its best efforts to maintain and promote
good public relations for PSE.
3.9.10 Sprint Spectrum acknowledges and anticipates that the Work
may be interfered with and delayed from time to time on account of the concurrent
performance of work by PSE or others. Sprint Spectrum shall fully cooperate with
PSE and others and coordinate the Work with such other work so as to minimize any
delay or hindrance of any work.
3.9.11 If any part of the Work depends upon the results of other work
by PSE or others, Sprint Spectrum shall, prior to commencing such Work, notify PSE
in writing of any actual or apparent deficiencies or defects in such other work that
render it unsuitable for performance of the Work. Failure of Sprint Spectrum to so
notify PSE shall constitute an acceptance by Sprint Spectrum of such other work as
suitable for performance of the Work, except as to latent defects which may
subsequently be discovered in such other work.
3.10 Upon completion of Permitted Activities which may disturb the
surface or subsurface of the Site (or any improvements thereon), Sprint Spectrum shall
restore the Site (and any improvements thereon) to a condition as good or better then the
condition the Site (or such improvements) was in prior to such disturbance.
3.11 If, in undertaking Pennitted Activities (or activities off -Site in
furtherance of Permitted Activities), Sprint Spectrum shall cause significant public concern
with or opposition to its proposed use of the Site, and PSE shall reasonably conclude that
such public concern or opposition will materially interfere with its use of the Site or
otherwise with the conduct of PSE's business, then PSE may direct Sprint Spectrum to cease
and desist such acts (or omissions) giving rise to such public opposition or concern.
3.12 Sprint Spectrum shall copy PSE's T&D Planning & Analysis
Department Director on all notices and other correspondence received or given by Sprint
Spectrum in connection with any local jurisdiction review process involving any Permitted
Activities undertaken or proposed to be undertaken by Sprint Spectrum at the Site.
4. E ui ment Structures and Facilities.
4.1 Sprint Spectrum shall maintain all Equipment on the Site in good and
safe condition and in a manner that does not materially affect the structural integrity of any
structure on the Site. If Sprint Spectrum fails to do any maintenance within thirty (30) days
after receipt of notice from PSE requesting such maintenance, then PSE may, at its option, do
such maintenance at Sprint Spectrum's expense and Sprint Spectrum shall reimburse PSE for
the entire expense thereby incurred. If Sprint Spectrum commences the requested
Sprint Spectruan SE63XC320
Marine View Substation — PSE (SEA123) Page 6
maintenance within thirty (30) days after any written notice from PSE requesting such
maintenance and thereafter continuously and diligently pursues and completes such
maintenance, then the thirty (30) day cure period will extend for an additional sixty (60) days
to permit Sprint Spectrum to complete the requested maintenance.
4.2 PSE shall at all times during the Term of this Permit, at PSE's sole cost
and expense, maintain any PSE-owned structures used by Sprint Spectrum for Permitted
Activities in a structurally good and safe condition. If Sprint Spectrum is unable to use such
structure due to PSE's maintenance activities, Sprint Spectrum may immediately install
temporary Equipment on any alternate location specified in the Site Development Plan while
PSE makes repairs to the Site.
4.3 If PSE at any time relocates, replaces or removes any pole, tower or
other facility or structure on which any Equipment is attached, or PSE otherwise determines
in its reasonable judgment that any Equipment must be removed or relocated to accommodate
PSE's use of or activities on the Site, then Sprint Spectrum shall, at its sole cost and expense,
remove or relocate such Equipment at such times and in the manner directed by PSE. If
Sprint Spectrum fails to remove or relocate its Equipment within one hundred eighty (180)
days (or such shorter period of time as PSE may reasonably require under the circumstances)
after being directed to do so by PSE, PSE may remove or relocate the Equipment at Sprint
Spectrum's sole risk and expense, and Sprint Spectrum shall reimburse PSE for the entire
expenses thereby incurred.
4.4 In the event Sprint Spectrum is permitted to and does install any pole,
tower or other structure as part of the Equipment on the Site, PSE shall have the right, subject
to such reasonable rules and requirements as the parties may agree upon in writing, to install
one or more items of equipment on such pole, tower or other structure for PSE's internaf
purposes only, provided that the pole, tower or structure in question is structurally capable of
bearing the weight of PSE's equipment. Such installation and use shall be at PSE's cost and
expense, but Sprint Spectrum shall not levy any charge or fee for PSE's use thereof.
S. Nonexclusive. This Permit is nonexclusive, and PSE may grant rights to
others to use the Site for any purpose not inconsistent with Sprint Spectrum's rights
hereunder. PSE does not warrant title to the Site and shall not be liable for defects thereto or
failure thereof. Without limiting any other provision of this Permit, Sprint Spectrum will
promptly resolve technical interference problems with other radio communications
equipment located at the Site on the date of this Permit or any radio communications
equipment located at the Site on any future date when Sprint Spectrum modifies or
supplements its Equipment at the Site. Likewise, PSE will not permit the installation of any
future radio communications equipment which results in technical interference problems with
Sprint Spectrum's then -existing Equipment at the Site; provided that the foregoing obligation
of PSE shall only apply if and to the extent PSE is expressly entitled by contract or applicable
law to prevent or reftise to permit such installation.
6. Cooperation of PSE. PSE shall, at Sprint Spectrum's expense, support
Sprint Spectrum's efforts to secure any documents or applications required (i.e., by virtue of
Sprint Spectrum SE63XC320
Marine View Substation —PSE (SEA123) Pagel
PSE's ownership of or rights in the Site) to be obtained by Sprint Spectrum from any
governmental agency with jurisdiction in order for Sprint Spectrum to obtain the necessary
licenses, permits or other approvals from such governmental agency for the Permitted
Activities; provided, however, that PSE shall not under any circumstances be obligated to
execute any application or other document that, in PSE's sole judgment, will in any way
impair, limit or adversely affect PSE's rights in or ownership or use of the Site, nor shall PSE
be obligated to provide such support if the same requires a commitment of resources of any
kind of a value in excess o
7. Emergencies. In the event of an emergency relating to the Equipment or the
Site, Sprint Spectrum shall immediately correct any safety or use problems, even if full repair
cannot be made at the time, in order to protect persons and property or to allow use of the
Site. The Parties' respective emergency phone numbers are as follows:
PSE:
Sprint Spectrum:
Each Party shall promptly notify the other of any change in such party's emergency phone
number.
8. UershiD and Risk of Loss of Efluipment.
8.1 The Equipment located at the Site pursuant to the terms of this Permit
will at all times be and remain the property of Sprint Spectrum and will not be subject to any
lien or encumbrance created or suffered by PSE. Sprint Spectrum has the right to make such
filings with the Washington State Department of Licensing (e.g., UCC-1 Financing
Statement) as it deems necessary or desirable to evidence its ownership of the Equipment.
Notwithstanding the foregoing, if, upon termination or expiration of the Tenn, the Equipment
is not removed from the Site and the Site restored according to the terms of this Permit, such
Equipment shall be deemed abandoned thirty (30) days following such termination or
expiration and PSE's waiver of lien shall thereafter be void and of no further force and effect.
8.2 Sprint Spectrum shall be responsible for and shall bear any and all risk
of loss, deterioration, theft, vandalism or destruction of or damage to the Equipment and
anything used (or to be used or consumed) in connection with the Work.
9. Examination of Records. Sprint Spectrum shall promptly furnish PSE with
such information related to the Work or the Equipment as may from time to
time be reasonably requested by PSE. Until the expiration of three (3) years
after the termination of the Term, PSE shall have access to and the right to
examine and copy all of Sprint Spectrum's books, documents, papers and
records which are related to the Work, the Equipment or this Permit.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 8
10. Compensation.
10.1 The "Annual Fee" shall mean the annual fee for Sprint Spectrum's use
of the Site as calculated in accordance with the schedule set forth in the attached Appendix 4
and the following:
10.1.1 The Annual Fee will be payable on or before the date of this
Permit and thereafter on the first day of the first month following each
anniversary of the commencement date of the Master Agreement, and
10.1.2 The Annual Fee will be prorated in the first and Iast year of this
Permit to coincide with the anniversary of the commencement date of the
Master Agreement. If Sprint continues to hold any Site after the termination
of the applicable Permit, whether the termination occurs by lapse of time or
otherwise, such holding over will, unless otherwise agreed to by PSE in
writing, constitute and be construed as a month -to -month tenancy at a
monthly Fee equal to of the Annual Fee for such Permit until
all of the Equipment is removed from the Site and restoration of the Site has
occurred according to the provisions of this permit, and will remain subject to
all of the other terms set forth in this Agreement.
10.2 PSE shall invoice Sprint Spectrum for all amounts payable by Sprint
Spectrum to PSE under this Permit (including, without limitation, the Annual Fees and all
reimbursable costs and expenses described elsewhere in this Pen -nit) as they become due.
Sprint Spectrum shall pay each such invoice in full within thirty (30) days after Sprint
Spectrum's receipt thereof.
10.3 Sprint Spectrum acknowledges that late payment of any fee or other
amounts due to PSE under this Permit will cause PSE to incur certain administrative,
processing accounting costs not otherwise contemplated by this Permit, the exact amount of
which will be extremely difficult, if not impossible, to ascertain. Accordingly, if any fee or
other amounts shall not be received by PSE within thirty (30) days after such amounts shall
first become due, Sprint Spectrum shall pay to PSE a late charge, as liquidated damages and
not as a penalty, equal to of such overdue amounts as a reasonable estimate
of the administrative, processing and accounting costs PSE will incur by reason of late
payment by Sprint Spectrum. Such late charge is intended to be in lieu of Sprint Spectrum's
liability for such costs, but shall not relieve or release Sprint Spectrum from liability for any
other costs or damages suffered by PSE by reason of late payment. Payment of such late
charge shall in no event excuse or cure any default under or breach of this Permit by Sprint
Spectrum.
10.4 In addition to any late charge levied under this Permit, Sprint Spectrum
shall pay to PSE interest, compounded daily, at the rate of per month or the
maximum rate permitted by applicable law, whichever is less, on any fees or other amounts
not paid to PSE when due under this Permit, from the date due until the date paid. Payment
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 9
of such interest shall not excuse or cure any breach of or default under this Permit by Sprint
Spectrum.
11. Taxes. Sprint Spectrum shall pay (except as otherwise required by law) all
fees and taxes applicable to or incurred in connection with the Work, the Equipment or the
system of which the Equipment constitutes a part. Subject to the foregoing, PSE shall pay all
taxes and other fees or charges attributable to each Site (including, without limitation, debt
and ground Iease obligations).
12. Site Acceptance.
12.1 Sprint Spectrum will be deemed to have accepted the Site upon
execution of this Site Permit. Conducting feasibility and cost assessments or other
preliminary inspections on the Site prior to execution of this Site Permit shall not be deemed
to be acceptance.
12.2 Acceptance of the Site by Sprint Spectrum in accordance with
paragraph 12.1 shall be conclusive evidence that Sprint Spectrum:
12.2.1 accepts the Site as suitable for the Permitted Activities;
12.2.2 accepts the Site and any structure on the Site and every part and
appurtenance thereof "AS IS," "WHERE IS" and "WITH ALL FAULTS AND
DEFECTS"; and
12.2.3 releases, and waives all claims against, PSE in respect of
defects in the Site and its structures and appurtenances, their habitability or suitability
for any permitted purposes, except as expressly provided otherwise in this Agreement.
12.3 PSE does not warrant the suitability of the Site for the purposes for
which Sprint Spectrum may desire to use it (including, without limitation, the Permitted
Activities); nor does PSE warrant the adequacy of the Site's location, its condition nor the
condition of any structure or appurtenances for any purpose. Sprint Spectrum acknowledges
that, in accepting the Site (and any and all structures thereon used by Sprint Spectrum for
Permitted Activities) in its "AS IS," "WHERE IS" and "WITH ALL FAULTS AND
DEFECTS" condition, PSE makes no representations or warranties whatsoever concerning
the Site and/or such structures, or any aspect of their status or condition, and that Sprint
Spectrum is not in any way relying on information disclosed by PSE with respect thereto, or
otherwise in PSE's possession with respect thereto; rather, Sprint Spectrum is solely relying
on its own inspections and assessments with respect to the condition or status of the Site
and/or such structures.
13. Term and Termination.
13.1 The term of this Permit (the "Term") will commence on the date of this
Permit and, unless earlier terminated as provided elsewhere in this Permit, will end upon
expiration of the term of the Master A Bement.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 10
to occur:
13.2 The Term will terminate automatically upon the first of the following
13.2.1 the term of the Master Agreement at any time expires or is
terminated for any reason;
13.2.2 any certificate, permit, license or approval affecting Sprint
Spectrum's ability to use the Site in the manner originally intended by Sprint
Spectrum is finally rejected or not likely to be obtained; or
13.2.3 any previously issued certificate, permit, license or approval
affecting Sprint Spectrum's ability to use the Site is canceled, expires, lapses, or is
otherwise withdrawn or tenminated by the applicable governmental agency.
13.3 PSE may at any time terminate the Tenn and all of Sprint Spectrum's
rights to use the Site upon:
13.3.1 sixty (60) days' prior written notice to Sprint Spectrum if any
Permitted Activity unreasonably interferes with (a) PSE's or any other prior existing
user's use of the Site, or (b) access to or around the Site or any structure adjacent to
the Site by PSE or any other prior existing users of PSE's property on or adjacent to
the Site and Sprint Spectrum fails to cure such interference to PSE's reasonable
satisfaction within such sixty (60) day period, or
13.3.2 the occurrence of any Event of Default.
13.4 Sprint Spectrum may terminate the Term upon thirty (30) days' prior
written notice to PSE if Sprint Spectrum is unable (e.g., for technological reasons) to use the
Site for the Permitted Activities or, due to significant opposition by any third party, it appears
unlikely that zoning can be obtained for the Site in a timely fashion; provided, however, that
Sprint Spectrum shall use reasonable efforts to obtain such zoning and/or resolve such
opposition.
14. Default.
14.1 The occurrence of any one or more of the following events constitutes
an "Event of Default" by Sprint Spectrum under this Permit:
14.1.1 Sprint Spectrum undertakes any activities on the Site other than
the Permitted Activities;
141.2 Sprint Spectrum fails to pay when due the full amount of any
fee or other payment under this Pen -nit, where such failure continues for fifteen (15)
days after written notice thereof by PSE to Sprint Spectrum;
14.1.3 Sprint Spectrum fails to cure any other default under or breach
of any provision of this Permit (i.e., other than a default or breach covered by
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 1 t
paragraph 11.1.1) within thirty (30) days after PSE gives Sprint Spectrum written
notice of such default or breach; except such thirty (30) day cure period will be
extended as reasonably necessary to permit Sprint Spectrum to complete cure so long
as Sprint Spectrum commences cure within the thirty (30) day cure period and
thereafter continuously and diligently pursues and completes such cure;
14.1.4 two (2) or more defaults by Sprint Spectrum in the payment of
any fee or other payments under the Permit which would allow PSE to issue a notice
of default in any twelve (12) month period, which such occurrence will constitute a
noncurable material default and breach of this Permit;
14.1.5 Sprint Spectrum deserts, abandons, or vacates any portion of a
Site and fails to maintain any and all Equipment remaining at the Site.
14.2 If an Event of Default occurs, PSE (without notice or demand except
as expressly required above) may, in addition to any other right or remedy to which PSE may
be entitled under this Permit or applicable law, recover from Sprint Spectrum an amount
equal to the sum of the following:
14.2.1 the actual costs of removing the Equipment and restoring the
Site to its original condition;
14.2.2 the Annual Fees for the Site until such time as the Site is
restored to its original condition, plus interest thereon from the date due until paid
according to the terms of this Pen -nit;
14.2.3 the amount by which the Annual Fees and other benefits that
PSE would have received under this Permit for the remainder of the Term after the
date of termination exceeds the amount of the fair market rental value for the
remainder of the Term that Sprint Spectrum proves could be reasonably avoided,
discounted at the discount rate on the date of termination of the Federal Reserve Bank
of the federal reserve district where the Site is located plus one percent=; and
14.2.4 all other sums of money and damages to which PSE may be
entitled hereunder or under applicable law.
15. Effect of Termination. Within thirty (30) days after termination of the Term,
Sprint Spectrum shall remove all Equipment from the Site and restore the Site to its original
condition except for reasonable use, wear and tear. Sprint Spectrum will repair any damage
to the Site caused during the removal of the Equipment. Following expiration of the above
thirty (30) day period, PSE shall furnish to Sprint Spectrum a Iist of any removal, restoration,
repair or other work that remains to be completed at the Site. Sprint Spectrum will thereafter
complete the work specified on the list within ten (10) days after receipt of the list from PSE.
If Sprint Spectrum shall fail to complete the specified work within the ten (10) day period,
PSE may complete the work, or have the work completed through the most expeditious
Sprint Spectrum SE63XC320
Marine View Substation— PSE (SEA123) Page 12
means available, at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall
reimburse PSE for the entire expense thereby incurred.
16. Release. Indemnity, Hold Harmless and Limitation of Liability.
16.1 Sprint Spectrum releases and shall defend, indemnify and hold
hanmless the Indemnitees from any and all claims, losses, costs, liabilities, damages and
expenses (including, but not limited to, reasonable attorneys' fees) arising (whether before or
after termination of the Tenn) out of or in connection with the conduct of the Permitted
Activities (including, without limitation, the Iocation of any Equipment at the Site, the
performance of the Work, or the operation of the Equipment or the system of which the
Equipment is a part), the enforcement of this Permit by PSE, any default under or breach of
this Permit by Sprint Spectrum or the acts or omissions of Sprint Spectrum or any of its
Support, the respective successors and assigns of Sprint Spectrum or any of its Support, the
directors, officers, employees and agents of each of the foregoing, or anyone acting on Sprint
Spectrum's behalf in connection with this Permit. To the fullest extent permitted by
applicable law, the foregoing release, indemnity and hold harmless shall apply regardless of
any act, omission, fault, negligence or strict liability of the Indemnitees; provided, however,
that Sprint Spectrum shall not be required to so indemnify any Indemnitee(s) against any
claim, loss, cost, liability, damage or expense to the extent the same is caused by or results
from the negligence or willful misconduct of any Indemnitee(s). In connection with any
action to enforce this paragraph 17.1, Sprint Spectrum waives any immunity, defense, or
protection under any workers' compensation, industrial insurance or similar laws (including,
but not limited to, the Washington Industrial Insurance Act, Title S 1, of the Revised Code of
Washington). PSE is willing to permit the Equipment on the Site for the fees described in
this Permit only in consideration of and in reliance upon such release, indemnity and hold
harmless. Consequently, such release, indemnity and hold harmless shall be construed
broadly in favor of the Indemnitees.
16.2 NOTWITHSTANDING ANY OTHER PROVISION OF THIS
PERMIT, PSE SHALL NOT HAVE ANY LIABILITY TO SPRINT SPECTRUM FOR
ANY: LOSS OF PROFIT OR REVENUE, LOSS OF USE OF THE EQUIPMENT OR THE
SYSTEM, CLAIMS OF CUSTOMERS OF SPRINT SPECTRUM FOR SERVICE
INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL, ECONOMIC OR
CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE
EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS
PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT
LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR
OTHERWISE, EVEN IF PSE HAS BEEN ADVISED OF THE POSSIBILITY OF THE
SAME.
16.3 NOTWITHSTANDING ANY OTHER PROVISION OF THIS
PERMIT, SPRINT SPECTRUM SHALL NOT HAVE ANY LIABILITY TO PSE FOR
ANY LOSS OF PROFIT OR REVENUE, CLAIMS OF CUSTOMERS OF PSE FOR
SERVICE INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL OR
CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA]23) Page 13
E
EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS
PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT
LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR
OTHERWISE, EVEN IF SPRINT SPECTRUM HAS BEEN ADVISED OF THE
POSSIBILITY OF THE SAME.
16.4 PSE'S LIABILITY (WHETHER IN TORT, CONTRACT OR
OTHERWISE AND NOTWITHSTANDING ANY FAULT, NEGLIGENCE (WHETHER
ACTIVE, PASSIVE OR IMPUTED), PRODUCT LIABILITY OR STRICT LIABILITY OF
PSE) UNDER THIS PERMIT OR WITH REGARD TO THE SITE SHALL IN NO EVENT
EXCEED THE COMPENSATION ACTUALLY PAID TO PSE UNDER THIS PERMIT
WITH RESPECT TO THE SITE.
17. Worker's Comoensaflop, Insurance and Bonds.
17.1 Sprint Spectrum shall ensure that Sprint Spectrum and all persons
undertaking any Permitted Activities, including without limitation Sprint Spectrum's Support,
maintain in effect at all times, coverage or insurance in accordance with the applicable laws
relating to worker's compensation and employer's liability insurance (including, but not
limited to, the Washington Industrial Insurance Act and the laws of the state in which any
such person was hired), regardless of whether such coverage or insurance is mandatory or
merely elective under the law. Sprint Spectrum shall furnish to PSE such assurance and
evidence of such coverage or insurance (such as copies of insurance policies and Certificates
of Compliance issued by the Washington State Department of Labor and Industries) as PSE
may request.
17.2 Sprint Spectrum shall secure and maintain in effect at all tunes during
the Term the following insurance:
17.2.1 fire insurance, with endorsements for extended coverage
vandalism, and malicious mischief, on the Site, in an amount not Iess than ninety
percent (90%) of the full replacement cost of the Site (including, without limitation,
all equipment and facilities located thereon); and
17.2.2 Commercial General Liability Coverage, including personal
injury, bodily injury, property damage, operations hazard, independent contractor
coverage, contractual liability, products and completed operations liability and stop
gap coverage, in limits not less than five million dollars ($5,000,000) for each
occurrence (combined single limit) with Sprint Spectrum named as insured therein
and PSE named as an additional insured therein as their respective interests may
appear.
17.3 All required insurance policies must be. taken out with reputable
national insurers that are licensed to do business in the jurisdiction where the Site is located.
Sprint Spectrum will deliver to PSE a Certificate of Insurance in the form attached to this
Permit as Appendix 5 prior to commencernent of performance of any of the Work. All
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 14
policies must contain an undertaking by the insurers to notify PSE in writing not less than
fifteen (15) days before any material change, reduction in coverage, cancellation or
termination of the insurance. Sprint Spectrum and PSE will each year review the limits for
the insurance policies required by this Permit. Policy limits will be adjusted to proper and
reasonable limits as circumstances warrant, but policy Iimits will not be reduced below those
stated in paragraph 17.2 and no increases in the policy limits will be effective unless Sprint
Spectrum and PSE mutually agree.
17.4 Sprint Spectrum shall also furnish PSE with such additional assurance
and evidence of such insurance (such as copies of all insurance policies) as PSE may from
time to time request. Within thirty (30) days after any notice of termination, cancellation,
expiration or alteration in any policy of insurance required under this Pennit, Sprint Spectrum
shall deliver to PSE a Certificate of Insurance acceptable to PSE with respect to any
replacement policy.
17.5 Sprint Spectrum shall ensure that any policies of insurance that Sprint
Spectrum or any of its Support carry as insurance against property damage or against liability
for personal injury (including death) or property damage shall include a provision therein
providing a waiver of the insurer's right to subrogation against the Indemnitees. To the extent
permitted by its insurance policies, Sprint Spectrum hereby waive all rights of subrogation
against the Indemnities.
17.6 All insurance carried by Sprint Spectrum or any of its Support shall be
primary insurance with respect to the interests of PSE, and any insurance or self-insurance
maintained by PSE is in excess and not contributory insurance with the insurance required
hereunder.
17.7 The requirements of this Permit as to insurance and acceptability to
PSE of insurers and insurance to be maintained by Sprint Spectrum are not intended to and
shall not in any manner limit or qualify the liabilities and obligations of or assumed by Sprint
Spectrum under this Permit.
18. Assignment. Successors and Assigns.
18.1 Sprint Spectrum shall not assign this Permit or any portion of its rights
in this Permit, except as follows:
18.1.1 to any person or entity that controls, is controlled by or under
common control with Sprint Spectrum (the "Acquiring Affiliate"); provided that
Sprint Spectrum gives PSE written notice of any such assignment or transfer and pays
all amounts then outstanding and owing to PSE under this Permit; provided further
that the Acquiring Affiliate certifies to PSE in writing (and provides such documents
as may be requested by PSE to establish) that the Acquiring Affiliate (i) will assume
all of the obligations of Sprint Spectrum under this Permit, and (ii) and will comply
with all of the provisions of this Permit; and provided further that Sprint Spectrum
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 15
furnishes to PSE such information regarding the Equipment affected by such
assignment or transfer as may reasonably be requested by PSE;
18.1.2 to Sprint Spectrum's lender(s) for security purposes in
connection with the financing and refinancing, from time to time, by Sprint Spectrum,
provided that upon any transfer pursuant to any foreclosure of such security or any
sale or other transfer in lieu of such foreclosure the person or entity acquiring the
interests subject to such transfer assumes all of the obligations of Sprint Spectrum
under this Pen -nit; or
18.2 Except as specifically provided in paragraph 18.1, any assignment or
apportionment, or purported assignment or apportionment of this Permit, whether it be
express, by operation of law or otherwise, shall be voidable by PSE. In any event, no
assignment or apportionment of this Permit shall relieve Sprint Spectrum from any of its
liabilities or obligations under this Permit. If at any time the aggregate net worth of Sprint
Spectrum and any Acquiring Affiliates bound by this Permit is less than
or Sprint Spectrum fails to furnish PSE evidence of such aggregate net
worth as PSE may reasonably request, then PSE will be entitled to immediately terminate the
Term upon written notice of such tennination to Sprint Spectrum. Subject to the foregoing
restrictions on assignments without the prior written consent of PSE, this Permit shall be
fully binding upon, inure to the benefit of and be enforceable by the successors and assigns of
the respective Parties hereto.
19. Casualty or Condemnation of the Site
19.1 If there is a casualty to any structure upon which the Equipment is
located, PSE will use reasonable efforts to repair or restore the structure within sixty (60)
days. Upon completion of such repair or restoration, Sprint Spectrum will be entitled to
reinstall the Equipment. In the event such repairs or restoration will, in PSE's reasonable
estimation, require more than sixty (60) days to complete:
19.1.1 Sprint Spectrum or PSE will be entitled to terminate the Tenn;
or
19.1.2 unless the Term is terminated as provided in paragraph 19.1.1,
Sprint Spectrum may immediately install temporary Equipment, including any
necessary supporting structure,
(a) at the Site, or
(b) at another unused portion of PSE's property adjacent to
the Site, to the extent Sprint Spectrum has the rights to do so,
while PSE makes repairs to the Site and so long as the temporary Equipment and
associated Work does not interfere with PSE's own restoration and operation of its
facilities.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA] 23) Page 16
19.2 If there is a condemnation of the Site, including without limitation a
transfer of the Site by consensual deed in lieu of condemnation, then the Term will terminate
upon transfer of title to the condemning authority, without further liability to either Party
under this Permit. Sprint Spectrum may pursue a separate condemnation award for the
Equipment and any relocation or other casts from the condemning authority provided that
such award does not reduce the amount of PSE's award.
20. Subordination.
20.1 Sprint Spectrum agrees that this Permit is subject and subordinate at
all tunes to the lien of all mortgages and deeds of trust securing any amount or amounts
whatsoever which may now exist or hereafter be placed on or against the Site or on or against
PSE's interest or estate therein, and any underlying ground lease or master lease on a
particular Site, all without the necessity of having further instruments executed by Sprint
Spectrum to effect such subordination.
20.2 This Permit is further subject to any and all restrictions or other terms
or conditions contained in the underlying ground lease, master lease, easement, license,
franchise, permit or other instrument of authorization or conveyance (an "Instrument") with
respect to the Site. Sprint Spectrum agrees to commit no act or Omission which would
constitute a violation of the terms and conditions of any Instrument for the Site insofar as
PSE has provided a copy of such Instrument to Sprint Spectrum or otherwise notified Sprint
Spectrum of the term or condition in question.
20.3 PSE shall not be required to obtain any consent required under any
Instrument from the landlord or other party to such Instrument for purposes of this Permit,
unless hereafter agreed upon by PSE in writing.
20.4 If a restriction contained in an Instrument for the Site prevents Sprint
Spectrum from installing, maintaining or operating the Equipment or accessing the Site,
Sprint Spectrum will be entitled to tenninate the Term.
20.5 Upon the termination or expiration of any Instrument with respect to
the Site, the Term shall automatically terminate without Iiability to either Party. Sprint
Spectrum acknowledges that many of PSE's underlying Instruments grant to the property
owner the right to terminate such Instruments, and that in the event of such termination, the
Term shall terminate concurrently therewith without liability to either Party.
20.6 Upon any sale or other transfer of all or any portion of the Site, the
Term will automatically terminate except to the extent the purchaser or transferee and Sprint
Spectrum enter into an agreement for Sprint Spectrum's continued use of the Site and release
PSE from any further obligation or liability with respect to the Site. PSE shall have no
obligation to request or obtain such agreement from the purchaser or transferee.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123) Page 17
20.7 PSE will not materially breach the terms or conditions of any
Instrument with respect to a particular Site in a manner that causes Sprint Spectrum to lose its
use of the Site.
21. Notices. Any notice, request, approval, consent, instruction, direction or other
communication given by either PSE or Sprint Spectrum to the other under this Pen -nit shall
be in writing and shall be delivered in person or mailed, properly addressed and stamped with
the required postage, to:
If to PSE: Puget Sound Energy, Inc.
P.O. Box 90868 GEN-02E
Bellevue, WA 98009-0868
Attn: Communications Siting and Services Department
If to Sprint Spectrum:
Sprint National Lease Management Sprint Law Department
6391 Sprint Parkway 6391 Sprint Parkway
Mailstop KSOPHT0101-Z2650 Mailstop KSOPHT0101-Z2650
Overland Park, KS 66251-2650 Overland Park, KS 66251-2650
Attn: Real Estate Attorney
Either Party may from time to time change such address by giving the other Party notice of
such change in accordance with the provisions of this paragraph 21.
22. No Partnership. This Permit shall not be interpreted or construed to create an
association, joint venture or partnership between the Parties or to impose any partnership
obligations or liability upon either Party. Neither Party shall have any right, power or
authority to enter into any agreement or undertaking for or on behalf of, to act as or be an
agent or representative of, or to otherwise bind the other Party.
23. Attornevs' Fees. The prevailing Party in any suit, action, or arbitration filed
or held concerning this Permit shall be entitled to recover, in addition to all other relief, its
reasonable attorney's fees incurred in connection therewith, both at trial and on any appeal.
24. Severability. The invalidity or unenforceability of any provision of this
Permit shall not affect the other provisions hereof, and this Permit shall be construed in all
respects as if such invalid or unenforceable provisions were omitted.
25. Survival. All provisions of this Permit which may reasonably be interpreted
or construed as surviving the completion, termination or cancellation of the Term or this
Pennit, shall survive the completion, tennination or cancellation of the Term or this Pen -nit.
26. Headings. The headings of sections and paragraphs of this Permit are for
convenience of reference only and are not intended to restrict, affect or be of any weight in
the interpretation or construction of the provisions of such sections or paragraphs.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 18
27. Nonwaiver. The failure of either Party to insist upon or enforce strict
performance by the other Party of any of the provisions of this Permit, or to exercise any
rights under this Permit, shall not be construed as a waiver or relinquishment to any extent of
its right to assert or rely upon any such provisions or rights in that or any other instance;
rather, the same shall be and remain in full force and effect.
28. Force Maieure. If a Party is delayed or hindered in, or prevented from
performance required under this Permit (other than any delay or failure relating to payment of
money, including, without limitation, the Annual Fees and all reimbursable costs and
expenses described elsewhere in this Permit) by reason of earthquake, landslide, strike,
lockout, labor trouble, failure of power, riot, insurrection, war, acts of God or other reason of
like nature not the fault of the such Party, such Party is excused from such performance for
the period of delay. The period for the performance of any such act shall then be extended
for the period of such delay.
29. Memorandum of Use. Neither Party shall record this Pen -nit or otherwise
cause this Permit to be recorded. However, upon the request of either Party, the Parties shall
execute, acknowledge, deliver and record a memorandum of use in form and content
substantially the same as the attached Appendix 6. Upon termination of the Tenn for any
reason, the Parties shall execute, acknowledge, deliver and record a termination document in
form and content acceptable to PSE.
30. Entire Agreement. The rights and obligations of the Parties hereunder shall
be subject to and governed by this Permit. This Permit sets forth the entire agreement of the
Parties, and supersedes any and all prior agreements, with respect to the Equipment, the
Work, the Site and other subject matter of this Permit. This Permit may not be modified
except by a writing executed contemporaneously herewith or subsequent hereto signed by
both Parties.
31. Applicable Law. This Permit shall in all respects be interpreted, construed
and enforced in accordance with the laws of the State of Washington.
32. Conditional Approval.
32.1 Sprint Spectrum shall provide complete detailed final jurisdictionally
approved construction drawings before construction begins for PSE's review and
approval. Said drawings shall show in detail the following, if applicable:
32.1.1 Grounding design of equipment and fencing in
accordance with the National Electrical Safety Code provisions in Section 9,
and PSE's internal design policies. Location of the telephone cable installation
{ from source to the equipment cabinets.
32.1.2 Field verification of location of property lines
establishing that proposed equipment shelter and pole location lies as noted,
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA123)
Page 19
1
32.1.3 Landscape design showing acceptable vegetation
compatible with electrical facilities and or substations.
32.2 Any comments and conditions noted during PSE's review process.
32.3 This is an existing Qwest Wireless site 4SEA123. Sprint Spectrum's
installation at the site will consist of utilizing a portion of Qwest
Wireless's existing antennas and coax on the monopole located on the
Substation property. Sprint Spectrum's BTS cabinets will also be
located in the existing cabinet area.
32.4 A list of materials and equipment provided to PSE in advance of
construction for PSE's review. Upon arrival, materials will be
delivered to the site of a mutually acceptable location and accepted by
PSE before construction commences.
32.5 No construction shall commence prior to the receipt and written
approval by PSE of the final construction drawings and evidence of
authorization by all governmental agencies having jurisdiction over the
project. An on site pre -construction meeting shall be scheduled prior to
construction and as -built drawings shall be provided after completion
of construction.
32.6 If any landscaping is part of the wireless facilities at this site it must be
approved by PSE, and it will be Sprint Spectrum's responsibility to
maintain the installed landscaping and meet the terms and conditions of
the landscape plan. If the installed landscaping is not maintained to
jurisdictional and/or PSE standards, then PSE may, at its option but not
an obligation, perform these maintenance activities at Sprint
Spectrum's cost and expense. Sprint Spectrum agrees to reimburse
PSE for these costs within thirty (30) days from the date of the
statement.
32.7 Sprint Spectrum will provide wireless facility specifications and design,
and will procure and install their wireless system with all costs being
paid by Sprint Spectrum as provided for herein. PSE will determine the
area available, if any, for Sprint's use. In the event PSE decides that
the space required by Sprint can not be provided, PSE may withhold
site approval.
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 20 '
o i
{
i i
Sprint:
Sprint Spectrum L.P.
Z
By. (;�
SP94T spEcTPiuM L.F.
PETER MUNSER
Its: SITE DEVELOPMENT MANAaF-R
(Title)
Date Signed:_ j
STATE OF _ a11r C
} SS
COUNTY OF
PSE:
Puget Sound Energy, Inc.
By:
Howard Strong
Its: Manager Real Estate
Date Signed: r--?N�yL --
On this � day of _ — _ _ 2004, before me, a Notary
Public in and for the State of C:-K---" duf commissioned and sworn, persly appeared
1�' �.V o me known to be the OTT
Vek./� " Sprint Spectrum that cuted the foregoing
instrument and acknowledged the same to be the free and voluntary act and deed of said municipal
corporation, for the uses and purposes therein mentioned, and on oath stated that he is authorized to
execute the said instrument.
Witness my hand and official seal hereto affixed tye clay and year in this certificate above
written.
r w , t/
USA D. fS my Print Nam L L
Commission # 1303787 Notary Pub is in and 1or the State of
-� Nofory, Public - Calitntnla Residing at
Fu°m4 county My commission expires {�
My Comm. Expires May 7, 2005
I
Sprint Spectrum SE63XC320
Marine View Substation — PSE (SEA 123) Page 21
JUN 10 2014
CITY OF FEDERAL WAY
e
08/07/2008
i
w
• ?'u44
1 dell Jove S I Nh A" S 1�
ar
Padit HWY $ mi"
P � PadMfc I-Irrr
a
2
r l
r
P �•
ss��y qy 1R'
r J I 10 jl
r'
U I Y OF FEDERAL WAY
CDS
At all new services & grounding trenches,
provide "WARNING" tape at 12" below grade,
DIG ALERT
"CALL BEFORE YOU DIG"
1-800-424-5555
UTILITY NOTIFICATION CENTER OF WASHINGTON
W
S p rintV%
WASHINGT N STATE CODE QO PLIANCEc
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS
ADOPTED BY THE LOCAL GOVERNING AUTHORITIES, NOTHING IN THESE PLANS IS
TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES.
• 2012 IBC, STANDARDS AND AMENDMENTS—WAC 51-50;
• 2012 IMC, STANDARDS AND AMENDMENTS—WAC 51-52;
2012 IFC, STAH[70M AND AMENDMENTS—WAC 51-54;
• 2012 IPC, STANDARDS AND AMENDMENTS—WAC 51-56; 51-57
ACCESSIBILITY
FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED
ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2009
IBC BUILDING CODE,
I CODE BLOCK j
SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS
FACILITY
• INSTALL 131
3NEW JWTENWI5 (1 PER SECTDR)
• INSTALL RRH UNITS (1 M SECTOR)
INSTALL 6 JUNCTION CYLINDERS (2 PER SECTOR)
• INSTALL 3 FILTERS
PROJECT DESCRIPTION
APPROVAL
SIGNATURE
DATE
BITE ACQUISITION
MANAGER
CONSTRUCTION
MANAGER
A&E MANAGER
PLANNING
CONSULTANT
RF MANAGER
RF ENGINEER
PROPERTY
OWNER
SPRINT
REPRESENTATIVE
AAV MANAGER
SIGNATLIRE BLOCK
THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY _ UlPMENT UPGRADE
2.5 LAUNCH
JEFFRIES
SE63XC320 / CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
LATITUDE: 47.339364 / 42° 20' 21 .71 " (NAD 83) (PER GOOGLE EARTH)
LONGITUDE:—122.311825 / 122° 18' 42.57" (NAD 83) (PER GOOGLE EARTH)
MONOPOLE
SEATTLE MARKET
a
^1tt'
•
C
y
3
f � � Game
E 9
•
.c �
� colas
svwa :""���
g
aa.ws
q
I - -
6 F
'"SITE`
—s••..a
0• sar.a
; �
8
can �
�, S u
�•'
'ie,
f�L
AREA MAP
9
z
L �
Izj 5 LTE r°+s
m
® •M1.- 7
i
VICINITY MAP
FROM GENERAL DYNAMICS IN BELLEVUE, WA
HEAD SOUTH ON 124TH AVE NE TOWARDS NE 10TH PL
0.1 l,11
TAKE SECOND RIGHT ONTO NE 8TH ST
0.7 NI
MERGE ONTO 1-405 SOUTH TOWARDS RENTON
13.9 MI
1-405 S BECOMES WA-518 W
0.1 Mi
MERGE ONTO 1-5 S TOWARDS PORTLAND
7.6 MI
TAKE EXIT 147 FOR S 272ND ST
0.3 N
TURN RIGHTT ONTO S 272ND ST
0.2 MI
TURN LEFT ONTO PACIFIC COAST HWY S/WA-99
1.0 M1
TURN LEFT ONTO S 288TH ST
0.8 MI
TAKE THE FIRST RIGHT ONTO 18TH AVE S
0.2 MI
DESTINATION WILL BE ON THE LEFT
29208 18TH AVE S, FEDERAL WAY, WA 98003, USA 24.67 MI
I DRIVING DIRECTIONS I
SHEET
DESCRIPTION
T-1
TITLE SHEET
N-1
GENERAL NOTES
A-1
PARCEL PLAN
A-2
ENLARGED SITE PLAN
A-3
EQUIPMENT PLAN
A-4
ANTENNA PLANS & SCHEDULE
A-5
EXISTING & PROPOSED EAST ELEVATION
A-6
EXISTING & PROPOSED NORTH ELEVATION
A-7
EQUIPMENT DETAILS
RF-1
ANTENNA AND CABLE COLOR CODING DETAILS
E-1
SCHEMATIC GROUNDING PLAN
E-2
GROUNDING DETAILS
E-3
GROUNDING DETAILS
SHEET INDEX
APPLICANT:
SPRINT SPECTRUM LLC
1000 124TH AVE NE. SUITE 210
BELLEVUE, WA 98005
CONTACT: KEVIN FOY
PH: (206) 427-5856
EMAIL: KEVIN.FOYOSPRINT.COM
PROPERTY IN7 4R�4ATIOhI
PROPERTY OWNER: PUGET SOUND ENERGY
ADDRESS: PO BOX 91269 BOT-01H
BELLEVUE. WA 98009
TOWER OWNER: CROWN CASTLE USA
SITE ID: 880427
ZONING CLASSIFICATION: BC COMMUNITY BUSSINESS
CONSTRUCTION TYPE: IIB
OCCUPANCY: U
JURISDICTION: CITY OF FEDERAL WAY
CURRENT USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY
NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY
PARCEL NUMSER(S]:
304020-0065
LEASE AREA:
810 SQ. FT.
PROJECT SUMMARY
ARCHITECT:
THOMAS R HOLLAND, AIA
PACIFIC TELECOM SERVICES, LLC
506 2ND AVE, SUITE 210
SEATTLE. WA 96104
CONTACT: AMANDA MARTIN
PH: (206) 342-6396
EMAIL: AMARTIN®PTSWA.COM
STR U CTU RAL LNG1 N EER:
B+T GROUP
1717 S BOULDER, SUITE 300
TULSA. OK 74119
CONTACT: VENU AMBATI
PH: (918) 587-4630
EMAIL- BTWO®BTGRP.COM
PROJECT MANAGER:
CROWN CASTLE USA
8432 154TH AVE NE, BLDG C
REDMOND, WA 98052
CONTACT: TOM GOODE
PH: (425) 202-0191
EMAIL: TOM.GOODE®CROWNCASTLE.COM
CONSTRUCTION MANAGER,
EN CASTLE USA 'APPROVAL
8432 154TH AVE N<
REDMOND.MWA 98952
CONTRC*: LEf RASSEfT �N1
PH: (206) 852-0443
ZONING & PERMITTING: of d
CROWN CASTLE USA.
8432 REDMOND.AVE H 4
CONTACT.-
D, WA 9805
CONTACT: KEVIN CF4WC rr 'f 11
PH: (425) 202-27
EMAIL: KENN.CHNiC
PUGEf SOUND EH L[f�^^��
CONTACT: TIM GASSE w �+L■ r G.v
PH: 206-947-0335
TELCO COMPANY:
CENTURYLINK
8502 SOUTH STEELE ST
TACOMA, WA 98409 PMEAfED
RE ENGINEER:
TBD JUN 10 2014
CITY OF FEDERAL WAY
CDS
PROJECT TEAM 1
Sprint>*
AS
0 CcOLE
r
•.c,na rccceer ccan�F.. L e
111 S JACKSON ST, 2N0 FLOOR
SEATTLE. WA 98104
PROJECT INFO A&NTION:
JEFFRIES
SEC 3XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE 02-25-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
IN[I1A1.S
A
11/29/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
6CENSURE
4072 REGISTERED
ARC IT T
THOMAS R. HOLLAND
STATE OF WASH INGTON
REN.02-18-16 _ l
"-so �)
SHEET TITLE
TITLE SHEET
SHEETNUMBER:
T-1
REVISION:
0
SE63XC32
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY
GENERAL NOTES: )
1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND NETWORK CARRIER
OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES AS THEY MAY BE
DISCOVERED IN PLANS, DOCUMENTS, NOTES, OR SPECIFICATIONS, PRIOR
TO STARTING CONSTRUCTION INCLUDING, BUT NOT LIMITED BY, DEMOLITION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR,
OMISSION, OR INCONSWENCY AFTER THE START OF CONSTRUCTION WHICH
HAS NOT BEEN 9ROUBNT TO THE ATTENTION OF ARCHITECT AND NETWORK
CARRIER CONSTRUCTION PROJECT MANAGER AND SHALL INCUR ANY
EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF CORRECTING ANY
ERROR SHALL FIRST BE APPROVED BY ARCHITECT AND NETWORK CARRIER
CONSTRUCTION PROJECT MANAGER.
2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT
THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS
AFFECTING THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE
COMMENCEMENT OF CONSTRUCTION AND THE CONTRACTOR HAVING BEEN
AWARDED THIS PROJECT SHALL VISIT THE CONSTRUCTION SITE WITH THE
CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND
CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR
TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT/ENGINEER VERBALLY AND IN WRITING.
3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN
THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF
WORK CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED
THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR
SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING
THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE NETWORK
CARRIER PROJECT SCOPE AND THE INTENT OF THESE DOCUMENTS, THE
BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE
ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR
TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF
DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR
EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE.
4. 11X17 COPIES OF DRAWINGS ARE NOT TO BE SCALED DUE TO
DISTORTIONS RESULTING FROM MULTIPLE REPROGRAPHIC COPIES, WRITTEN
DIMENSIONS TAKE PRECEDENCE OVER SCALES SHOWN ON PLANS.
5- OWNER, CONTRACTOR, AND NETWORK CARRIER REPRESENTATIVE SHALL
REVIEW AND CONFIRM THAT PROJECT SCOPE, DESIGN INTENT AND UTILITY
COORDINATION ITEMS ARE INCLUDED IN THE DRAWINGS AND
SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION.
6 THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION FROM NETWORK
CARRIER REPRESENTATIVE TO PROCEED WITH CONSTRUCTION PRIOR TO
STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE
CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS.
7.. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED
HOURS TO AVOID DISTURBING NORMAL BUSINESS OR TENANTS.
8. THE CONTRACTOR SHALL PROVIDE NETWORK CARRIER PROPER INSURANCE
CERTIFICATES NAMING NETWORK CARRIER AS ADDITIONAL INSURED, AND
PROVIDE NETWORK CARRIER PROOF OF LICENSE(S) INCLUDING PE & PD
INSURANCE,
9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED
IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE SOLELY
RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE
WORK UNDER THE CONTRACT-
10, THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS
ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED
OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE
11. ALL WORK PERFORMED ON THE PROJECT ALONG WITH ALL MATERIALS
INSTALLED, SHALL COMPLY IN STRICT ACCORDANCE WITH ALL APPLICABLE
CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL LIKEWISE
ISSUE NOTICE TO ALL SUB -CONTRACTORS THAT THEY SHALL COMPLY WITH
ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF
ANY PUBLIC AUTHORITY, MUNICIPALITY, UTILITY COMPANY AND LOCAL/STATE
JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK,
12. A COPY OF THE GOVERNING AGENCY ISSUED AND APPROVED PLANS SHALL
BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY
LAW, SHALL BE AVAILABLE AT THE JOB SITE FOR INSPECTION AT ALL
TIMES. THE ORIGINAL PERMIT SET PLANS ARE NOT TO BE USED BY THE
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME
INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR
SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION,
COMPLETE WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE
PREMISES AT ALL TIMES UNDER THE DIRECT CARE OF THE
SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY THE NETWORK
CARRIER CONSTRUCTION PROJECT MANAGER WITH A COPY OF ALL
REVISIONS, ADDENDA, AND/OR CHANGE ORDERS AT THE CONCLUSION OF
THE WORK AS A PART OF THE AS -BUILT DRAWING RECORDS-
13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES
ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS
NOTED OTHERWISE,
14. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL,
MECHANICAL, AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS,
NOTES, DIMENSIONS, AND ALL REQUIREMENTS PRIOR TO THE START OF
ANY WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY
OF THE JOB SITE WHILE WORK IS IN PROGRESS UNTIL THE JOB IS
COMPLETE
16. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING
UTILITIES SHOWN OR NOT SHOWN ON THE PLANS, ALONG WITH
PROTECTING THEM FROM DAMAGE. THE CONTRACTOR AND SUBCONTRACTOR
SHALL BEAR THE EXPENSES OF REPAIR AND/OR REPLACEMENT OF
UTILITIES OR OTHER PROPERTY DAMAGE RESULTING FROM OPERATIONS IN
CONJUNCTION WITH THE EXECUTION OF THE WORK.
17. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE
REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL
BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS:
A PROPERTY NOTED TO BE RETURNED TO THE OWNER.
B. PROPERTY NOTED TO BE REMOVED BY THE OWNER.
18- THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS
SHALL PROVIDE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES,
MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT, TRADE
STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING
OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION.
19, WHEN ROOF TOP OR TOP FLOOR DECK TEMPORARY STAGING IS REQUIRED,
MATERIALS SHALL BE EVENLY DISTRIBUTED OVER ROUGH FRAMED FLOORS OR
ROOFS SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE
STRUCTURE, TEMPORARY SHORING AND/OR BRACING IS TO BE PROVIDED
WHERE THE STRUCTURE DOESN'T HAVE THE DESIGN STRENGTH FOR
ADDITIONAL LOADING,
20- SEAL ALL PENETRATIONS WITHIN FIRE -RATED AREAS WITH U.L. LISTED OR
FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THE SUBJECT
FACILITY AND OR PROJECT SITE.
T INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE
21. BUILDING /
NOTIFIED PRIOR TO ANY GROUND DISTURBANCE, CONSTRUCTION, AND ANY
OTHER PROJECT EFFORT AS MANDATED BY THE GOVERNING AGENCY.
22. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF
NOT LESS THAN 2-A OR 2-AIOBC WITHIN 75 FEET TRAVEL DISTANCE TO
ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION,
23. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING
IMPROVEMENTS, EASEMENTS, PAVING, CURBING, DURING CONSTRUCTION. UPON
COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY
HAVE OCCURRED DUE TO CONSTRUCTION ON OR ADJACENT TO THE
PROPERTY.
24. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE
DURING CONSTRUCTION DISPOSING OF ALL DIRT, DEBRIS, AND RUBBISH.
CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON
THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND
FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE,
25. NEW CONSTRUCTION INSTALLED ADJACENT EXISTING BUILDINGS OR
CONSTRUCTION SHALL ARCHITECTURALLY MATCH THE EXISTING IN TERMS OF
COLOR, TEXTURE, FINISH MATERIALS, ETC., EXCEPT AS NOTED IN THE PLANS
AND SPECIFICATIONS.
26. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING,
AND/OR OTHER ANCHORAGE DEVICES REQUIRED FOR THE INSTALLATION OF
FIXTURES, MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS
TO INSURE A PROPER AND CODE COMPLIANT INSTALLATION.
27. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSTALLATIONS THAT ARE
CONSTRUCTED LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE BASED ON
THE CONSTRUCTION DRAWINGS. THE CONTRACTOR SHALL COMPARE EXISTING
CONDITIONS WITH THE PROPOSED DESIGN PRIOR TO CONSTRUCTION AND
REPORT ANY DISCREPANCIES OR INCONSISTENCIES TO THE NETWORK
CARRIER'S REPRESENTATIVE AND FURTHER TO THE A&E SUCH THAT THE NEW
INSTALLATION WILL LIKEWISE BE LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND
TRUE. ARCHITECT AND NETWORK CARRIER SHALL BE NOTIFIED OF ANY
ERRORS, OMISSIONS, OR INCONSISTENCIES PRIOR TO ANY CONSTRUCTION.
28. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES
FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE
GOVERNING AGENCIES.
29. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS
AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY
RESPONSIBLE FOR RECORDING THE RESULTS.
30. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS
AND SHALL NOT STORE OR STAGE MATERIALS ON PUBLIC PROPERTY WITHOUT
A PERMIT TO DO SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE
31. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS
TO BE USED IN ALL CONDITIONS UNLESS ILLUSTRATED AND NOTED
OTHERWISE.
32. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN
CUTTING, FITTING, PATCHING, ETC., SO AS TO BE PREPARED PROPERLY BY
THE WORK OF OTHER TRADES.
33. ALL DEBRIS AND REFUSE SHALL BE REMOVED FROM THE PROJECT PREMISES
AND LEFT IN A CLEAN SWEPT CONDITION AT ALL TIMES BY EACH TRADE AS
THEY PERFORM THEIR OWN PORTION OF THE WORK.
34. NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES, AND/OR
ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER GUARANTEE OR
WARRANTY THAT MAY BE IN EFFECT IS DONE THROUGH THE COMPANY OR
MANUFACTURER PROVIDING THE PRODUCT, FIXTURE, AND/OR EQUIPMENT
UNLESS SPECIFIC RESPONSIBILITY IS ALSO PROVIDED BY THE
CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM,
35. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA
AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE
ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO
CONSTRUCTION.
36. WHEN APPLICABLE, CONTRACTOR IS RESPONSIBLE TO CALL, COORDINATE AND
MAKE ARRANGEMENTS FOR R.O.W. AND/OR PRIVATE PROPERTY LOCATES
BASED ON SPECIFIC SITE REQUIREMENTS.
37_ SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION AS APPLICABLE.
38. CONTRACTORS TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS
AND SUBMIT TO NETWORK CARRIER'S REPRESENTATIVE ALONG WITH REDLINED
CONSTRUCTION SET.
39. CONTRACTOR SHALL DOCUMENT ALL CHANGES MADE IN THE FIELD BY
MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND
SUBMITTING THE REDLINED ALONG WITH PHOTOGRAPHS PER NETWORK
CARRIER REQUIREMENTS.
40. CONTRACTOR SHALL COORDINATE AND SEEK APPROVAL OF ALL POWER DRAW,
INSTALLATION AND/OR MODIFICATIONS WITH POWER COMPANY, OWNER AND
JURISDICTION AS REQUIRED. CONTRACTOR SHALL REPORT POWER
INSTALLATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT
CONSTRUCTION MANAGER AND ARCHITECT.
41. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED
BY NETWORK CARRIER CONSTRUCTION MANAGER
42. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL
FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR
FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPLETE
ACCEPTING UNDER THIS CONTRACT BETWEEN THE OWNER AND THE
CONTRACTOR EXCEPTION: THE ROOFING SUBCONTRACTOR SHALL FURNISH A
MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE
CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A
PERIOD OF TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL
COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE
CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR.
ANTENNA & COAX NC.. _S
43. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY
OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE 1.
CONSTRUCTION OF THE PROJECT.
44. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS 2.
AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT,
BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS
REPRESENTATIVE CONTRACTOR SHALL OBTAIN PERMIT (UNLESS OTHER
ARRANGEMENTS HAVE BEEN MADE) AND MAKE FINAL PAYMENT FOR SAID
DOCUMENT(S).
3.
45- NETWORK CARRIERS REPRESENTATIV
E SHALL REVIEW AND APPROVE SHOP
DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT.
NETWORK CARRIER'S REPRESENTATIVE PROJECT APPROVAL OF A SEPARATE
OF A U APPROVAL N ASSEMBLY IN WHICH THE ITEM
ITEM SHALL NOT INCLUDE AP RO
FUNCTIONS.
VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL
APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE.
THE MAXIMUM COAXIAL CABLE LENGTH AND CORRESPONDING COAXIAL CABLE DIAMETER HAS
BEEN ESTIMATED. THIS CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR
FABRICATION OR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH($) MAY VARY FROM
ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. COAXIAL GABLE SHALL BE PROVIDED BY
NETWORK CARRIER REPRESENTATIVE
ALL MAIN CABLES SHALL UTILIZE GROUND KITS, GROUNDED AS FOLLOWS:
A NEAR ANTENNA RAD CENTER ELEVATION,
B. MIDDLE OF TOWER (MID -HEIGHT OF ANTENNA). IF CABLE RUN IS OVER 200'.
C. BOTTOM OF TOWER,
D. AT MASTER GROUND BAR 3'-0" FROM MMBS-BBU CABINET.
4.
ALL TOP JUMPERS SHALL BE LENGTHS AS SHOWN AND INSTALLED RY CONTRACTOR.
46. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY
NETWORK CARRIER
5.
ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS
47. CONTRACTOR SHALL PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR
SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS.
SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY
EQUIPMENT UTILIZED DURING CONSTRUCTION.
6.
BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON
RF SHEET(S) AND AS FOLLOWS:
48. CONTRACTOR SHALL PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE
A. MAIN LINE COLOR BANDS SHALL BE 2" WIDE MAINTAIN 1" SPACING BETWEEN COLORS
CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND
B. FREQUENCY COLOR BANDS SHALL BE 2" WIDE WITH NO SPACE BETWEEN COLORS,
MAINTAIN EXISTING SURFACE DRAINAGE SLOPES
C. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE-
49. CONTRACTOR SHALL REPLACE EXISTING LANDSCAPE VEGETATION DAMAGED DUE
D. START COLOR BANDS 2" BEYOND WEATHERPROOFING.
TO CONSTRUCTION ACTIVITIES, AND REPAIR, RESTORE AND MODIFY EXISTING
E. START SELECTOR COLOR NEXT TO END CONNECTORS.
IRRIGATION LINES IF NECESSARY TO OPERATING CONDITION, PROVIDING FULL
COVERAGE TO IMPACTED AREAS.
7.
FINAL COAXIAL ANTENNA CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF
ENGINEER. SEE ANTENNA SCHEDULE
50. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR,
8,
SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE.
CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER TO OBTAIN CONTACT
INFORMATION AND UTILIZE THE EXISTING ROOFING CONTRACTOR OF RECORD
9.
ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES
FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF,
NOT TO EXCEED 3' OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH
AND HAVING THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S
HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL
EXISTING WARRANTY ENSURING 100% MOISTURE PROTECTION.
REPORT.
51. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS
WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, CONTRACTOR
10.
PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING
SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT
ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT.
THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) EXISTING EXTERIOR
G FACADE CTOR
RES. AND COLORS. EOR FLATHEAD
�L1 q� Vpp COAX
& HYBRID COAX NOTE
SHALL FURTHERMORETENISURETTIXHE)U E OF COUNTERSUNK
ANTENNA
FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE
PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION
T.
VERIFY EACH HYBRID CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL
REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS
APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE.
SHALL BE PROVIDED TO THE CONTRACTOR, CONSTRUCTION COORDINATOR,
AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION,
_
ETER HAS BEEN ESTIMATED THIS
52. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA
FRAMES WHERE ANCHORING TO AN EXISTING CONCRETE ROOF SLAB IS
REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH
CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF
POST TENSION TENDONS WITHIN THE ROOF SLAB RESULTING FROM AN
UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT 3.
DRAWING SET" HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF
REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST
TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE 4,
PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL
PENETRATION AREAS WHERE ANCHORING OCCURS.
53. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING 5.
TIES FOR ALL CABLING TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS
(WHERE APPLICABLE). PLASTIC ZIP TIESHALL NOT SHNOT BE PERMITTED FOR USE
ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE &
SHALL BE PANDUD CW. METAL LOCKING TIES MODEL HO. MLT4S-CP
UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC.
54- CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER
CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID
AND CONSTRUCTION PROJECT-
7.
55. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER
CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID
AND CONSTRUCTION PROJECT.
8.
56. CONTRACTOR SHALL BE RESPONSIBLE TO SET ELECTRONIC TILTS FOR NEWLY
INSTALLED ANTENNAS UNDER THE CONDITION THAT THE CONTRACTOR OBTAIN
THE MOST RECENT COPY OF THE RF TILT INFORMATION SUCH THAT THE
ACCURATE CONTROLLER CAN BE ORDERED AND INSTALLED.
57. A STRUCTURAL ANALYSIS SHALL BE COMPLETED AND SUBMITTED TO THE
NETWORK CARRIER REPRESENTATIVE AND CONTRACTOR DEMONSTRATING
CAPACITY AT THE EXACT LOCATION OF EXISTING CONDITIONS TO SUSTAIN
ADDITIONAL HEAVY BATTERY CABINETS OR OTHER OUT OF SCOPE EQUIPMENT-
5& THE CONTRACTOR SHALL PROVIDE MATERIALS LIST (BOM) TO THE NETWORK
CARRIER REPRESENTATIVE PRIOR TO CONSTRUCTION.
THE HYBRID CABLE LENGTH AND CORRESPONDING DIAM
CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR
CONSTRUCTION- ACTUAL ANTENNA CABLE LENGN(S) MAY VARY FROM ESTIMATED MAXIMUM
LENGTH AND MUST BE VERIFIED. EXCESS CABLE LENGTHS TO BE DRESSED IN A MANNER
APPROVED SY NETWORK CARRIER REPRESENTATIVE- CABLES CANNOT BE CUT TO FIT.
HYBRID CABLE INTERNAL GROUND WIRE TO BE GROUNDED AT TOP AND BOTTOM PER NETWORK
CARRIER SPECIFICATIONS.
EXCESS TOP 15' HYBRID CABLE FIBER JUMPERS TO BE DRESSED IN A MANNER APPROVED BY
NETWORK CARRIER REPRESENTATIVE, CANNOT BE COILED, MUST BE SECURED TO TOWER
MOUNTS.
ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS
SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS.
BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON
OF SHEET(S) AND AS FOLLOWS:
A. MAIN LINE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS.
B. JUMPER COLOR BANDS SHALL BE 1" WIDE WITH 1" SPACE.
C. START COLOR BANDS 2" BEYOND WEATHERPROOFING.
FINAL HYBRID CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF ENGINEER. SEE
CABLE SCHEDULE, BASED UPON FINAL RUN LENGTHS DETERMINED BY NETWORK CARRIER
REPRESENTATIVE. -
ALL HYBRID CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES
NOT TO EXCEED 3' HORIZONTALLY OR 4' VERTICALLY OR THE CABLE MANUFACTURES
SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE
ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT.
t.
Spri ntP
■ l S'Y
MCCO�
r ram
PACIFIC TELECOM SERVICES, L C
III S JACKSON ST. 2ND FLOOR
SEATTLE, WA 99104
PROJECT INFORMATION:
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE- 0 2- 2 5- 1 4
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
IINRIAL5
A
)1/29/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
L I C ENS U R I--
4072 REGISTEJT
ARCHIT
THO dAS R. HOLLAND
STATE OF WASHINGTON
REN, 02-18.15 _ l
woomm
SHEET TITLE
GENERAL NOTES
SHEETNUNABEK:
N-1
REVISION:
0
SE63XC32
THE
IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIEiRRY ETY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY
1
T
0)
LLI
F-
0
fr
w
F-
F-
�. f i
i;N• ;
NIN I
�-
T1T ry -7
j =r
A.4i=N.1A ..
m S^If?ACK ;
w .
z
a
1�
o
M z
itiJ 4 w
�- f••; �.�.�.'� � EXISTING
i SPRINT SITE a
EXISTING
PARKING
r fff'
ZONING: BC I J EX STING
✓f BUILDING
EXISTING
PARKING //-7
f
ZONING: BC
APN:
.= I. 3oao2a-ooss
x
✓
O
EXISTING
BULDING
=
a
o
x
0
a
o
S
O
EXISTING -
DISTRIBUTION
d
x
0
U�
l
EXISTING
.�
. �•-'�
OVERHEAD
a
ITRIWSMISSWN=-�
o
a
=rl5y j�'�s-•.' �; fir. s•;.�
4��_�-• T� � fir:
� r
�Y ,• tlptizfa
ELECT SUBSTATION;4� q
1L
TREES�.,x
./ PROPERTY LINE (322.79')
EXISTING
BUILDING
/ r
EXI571H[i •F
.. mis
.' EXISTING
BUILDING �.
// 4• e
EXISTING
PARKING 7 JS +
Ye�..
A
GENERAL NOTES
THESE DRAWINGS WERE PRODUCED WITHOUT THE
BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY
LINES, EASEMENTS, SETBACKS AND EXISTING
CONDITIONS ARE APPROXIMATE AND SHALL BE VERIFIED
PRIOR TO START OF CONSTRUCTION.
m
a
>
',
DO
!
r
`
o
EXISTING
BUILDING
f
, _
}
o
� E>[7311ftG � O
'Jir'_ -
y
EXISTING
PARKING
-
o
71
24"x36" SCALE: 1" = 20'-0" PARCEL PLAN 1
11"x17" SCALE: 1" = 40'-0" 2 0
Tur iKII-Ph—l——NTAINPn IN THIc CPT Ar f'nNSTRLJ(l.TlON nnCL1MFNTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PRD819TTFD.
Spri nt);p
C OWN
ASTL E
-ramIC TELECOM YI ES
111 S JACKSON ST, 2ND FLOOR
SEATTLE. WA 98104
PROJECT NFORMAl10N:
JEFFR.IES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE, 02-25-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITIALS
A
)1/29/14
ISSUED FOR 90% CONSTRUCTION
AF
p
)2/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICH (SURE
4072TISTERED
CHITT
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. Q2-181 �
9�
SHEET TITLE
PARCEL PLAN
SHEETNUMBER:
A-1
REVISION:
0
SE63XC320
21'—S"
C-3'
(GATE)
k
k �
k
X— X— X— X— X— X— X— X— X— X— X— X— X— X— X— X— X -- X
x EXISTING SPRINT x
EQUIPMENT CABINETS
x x
m I
X Ix
! I I
x I o I- 1
1 I I I
x
x EXISTING 85'-0"
I I AGL MONOPOLE _.
EXISTING SPRINT ANTENNA ac I I , x
LOCATION AT EXISTING
MODIFICATION LOCATTIIOND I I EXISTING SPRINT
HYBRID CABLE I I x
ROUTE
I EXIST" SPRINT � I a
ICE BRIDGEz
I U -s
I E
X n U
2
N
I
I I � W
I
---- -------------- x
I
x 1 x
� I
EXISTING SPRINT x
I EQUIPMENT/LEASE
AREA AT CONCRETE
PAD ON GROUND — x
NO PROPOSED
MODIFICATION
x x
I
EXISTING OTHER CARIER x
EQUIPMENT SHELTER
f
x x
I
x x
I
as x
LX�X—X— x—x—x—X—X—X —.X—X X -X- X-X---X-X-X-X-X-x-X---x�
25,-V
(EXISTING COMPOUND AREA)
2406" SCALE: 1/2" = 1'-0" 1
11"x17" SCALE: 1ENLARGED SITE PLAN
/9' = 1'-0" 2 1' Q 2'
— IN—PWATI— r—TAINM IN THIC Rc nr CANSTRIiMONL 00r.[JMFNTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROI.11911ED.
Spri nt);o
YY
acIfflzf5
�-ram
PACIT Ic TELECOM SERVICES. LLC
111 5 JACKSON ST. 2ND FLOOR
SEATTLE, WA 9Bf04
PROJECT INFORMATION:
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE- O 2 - 2 5 -14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV,
GAS2
DESCRIPTION
IH1TLQs
A
01/29/14
ISSUED FOR 90% CONSTRUCTION
AF
0
D2/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 REGISTERED
ARC IT T
THOiM1AS R. HOLLAND
sTATE OF WASH INGTON
REM.0som Two
willmo
SHEET TITLE
ENLARGED SITE PLAN
SHEETNUMBEIL
A —2
REVISION:
O
SE63XC32Q
EXISTING SPRINT
POWER CABINET -
EXISTING 6'-6" X
12'-0" CONCRETE
EXISTING SPRINT
HYBRID CABLE R
EXISTING SPRINT
GPS ANTENNA —
EXLSTING SPRINT
EXISTING
SPRINT
BBU
CABINET
.. EXISTING
SPRINT
MMBS
_. CABINET
Ji
N IQ
NOTE:
NO PROPOSED WORK TO EXISTING
SPRINT GROUND EQUIPMENT
Np�
(MSTWG SPRINT LEASE AREA)
E%ISi1HC
METER BOARD
24"x36" SCALE: 1/2" = r-o• EQUIPMENT PLAN 1 NOT USED 2
11.x17" SCALE: IA' = 1'-0" .2 1 D 2'
NOT USED 3 NOT USED 4
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCU6XENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint
C �J 111I! ■
ASTLE
;==-ram
P IFIC TELECOM SERVICES, LLC
Ae111 S JACK SON 5T, 2N0 FLOOR
SEA77LE. WA 98104
PROJECT INFORWTION:
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE 02-25-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
A
0'/29/,4
ISSUED FOR 90% CONSTRUCTION
0
2/25/14I
ISSUED FOR 100% CONSTRUCTION
FGA
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICEVSLIRE
4072 REGISTERED
AI�CHIT T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REM.6mma
SHEET TITLE
EQUIPMENT PLAN
SHEETNUIMBER-
A-3
REVISION:
0
E63XC320
--1
f�\
<
01N
A
�a•��ly�/,
r
�
9. 2.
24'e36' SCALE: 1/2" = 1'-O"
11"07" SCALE: 1/4" = 1'-O"
/1\
<
I�
0_ r �_
0 1 nl
C)IQ
L r4�Ar.NC
o`o
PROPOSED SPRINT
e2.5GHz ANTENNA MOUNTED
7 ON EXISTING MOUNT
(1 PER SECTOR, 3 TOTAL)
PROPOSED SPRINT
5 2.5G1-1z RRH MOUNTED
_7 BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
24"r36` SCALE: 1f2" - 1'-0'
,1_ 1':
SCALE: 114" .. 1'-0' 2 1' 2'
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS
0-7
EXISTING EMPTY
PIPE MOUNT (TYP)
EXISTING W-0'
HIGH MDNOPOLE
_err
EXISTING SPRINT 190OMHz ANTENNA
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 190OMHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
- 'lfc
EXISTING ANTENNA PLAN I 1
NOT USED 1 2,
NOTE:
STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRUS, & NEW CABINETS/TEMPORARY
PLATFORM.
NOTE:
EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE
JA',{Wl NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA SIMILAR TO THAT SHOWN ON DETAIL 1, SHEET A-7.
-1A�a F r+ FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS.
NOTES:
AL! A2MWTF6 ARE TD BE E5iABLISHED CipCHWi$£ FROM THE TRUE NORTH HEADWC. f,OT1TRAEI(!R SHALL VERIFY NEW TOANTENNA RAO AEON AND QRANALYIED WITH SPRINT PCS
PRIOR IO IkST�ILLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXP611NG TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LIC£H5£D
STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO TOWER
STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER.
EXISTING 85'-0"
HIGH MONOPOLE
w
I as
z I.-. f
gI� EXISTING SPRINT 1900MHz ANTENNA
a_ D (1 PER SECTOR, 3 TOTAL) TRUE w4NlK
Sri NORTH xvm,
Z)� :EXISTING SPRINT 190OMHz RRH
tjl MOUNTED BEHIND ANTENNA
nib (1 PER SECTOR, 3 TOTAL)
JT
RRU / HYBRID CABLE SCHEDULE
SECTOR
RRU MODEL
RRU FREQUENCY
HYBRID CABLE
LENGTH
HYBRID CABLE
DIAMETER
JIJ61P6R
SIZE
.JUMPER
LENGTH
RET
ILENGTH
RET CCALE
MANUFACIUR
RET CABLE
MODEL NUMBER
ALPHA
RRH-V3
2.5 GHz
120
N/A
1/2"
6'
9.8
COMMSCOPE
TCB-B01-006
BETA
RR
It GHz
120
N/A
1/2'
6'
9.8'
COMMSCOPE
TCB-B01-006
GAMMA
RRH-V3
2.5 GHz
120'
N/A
7/2"
1 6'
1 9.8'
1 COMMSCOPE
TCB-BOI-006
ANTENNA SCHEDULE
SECTOR
ANTENNA
FREQUENCY
ANTENNA
MFR.
ANTENNA
MODEL
ANTENNA
QUANTITY
AZIMUTH
RAD CENTER
ANT. SIZE
ELECT TILT
<CH TILT
ALPHA
2.5 GHz
KMW
ET-X-WM-18-65-8P
1 (PER SECTOR)
0'
eY-0'
BETA
25 GHz
KMW
ET-X-WM-18-65-BP
1 (PER SECTOR)
120'
61.0"
GAMMA
2.5 GHz
KMW
ET-X-WM-18-65-8P
1 (PER SECTOR)
240-
62-0"
1 61.0"
0-
0-
NOTES & ANTENNA SCHEDULE1 4
BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY
\U._
G
NI
24"x36" SCALE: 3/16" = 1'-O'
11"x17" SCALE:y3r = 1'-0"
THE INFORMATION CONTAINED IN 1
INA
EXISTING EAST ELEVATION 1 11 x36" SCALE: 3/16' - 1'-0"
"x17" SCALE: 3/32" - 1'-0'
DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICE$ IS STRICTLY PROHIBITED.
4'
�-X )
EXISTING LIGHTNING ROD
PROPOSED SPRINT
25GHz ANTENNA MOUNTED 2
ON EXISTING MOUNT 7
(1 PER SECTOR, 3 TOTAL)
PROPOSED SPRINT
2.5GFtzBEHIND ANTERRH NMOUNTEDNA 7
5
(1 PER SECTOR. 3 TOTAL) -
EXISTING SPRINT 1900MHz ANTENNA
(1 PER SECTOR, 3 TOTAL)
EXISTING SPRINT 190OMHz RRH
MOUNTED BEHIND ANTENNA
(1 PER SECTOR, 3 TOTAL)
NOTE:
STRUCTURAL ANALYSIS MUST BE
PREFORMED ON ALL ROOFTOPS,
FLAGPOLES AND TOWER SITES
BEFORE INSTALLATION OF NEW
ANTENNAS, NEW RRH UNITS, & NEW
CABINETS/TEMPORARY PLATFORM,
ANALYSIS TO BE PERFORMED BY
REGISTERED STRUCTURAL ENGINEER
EXISTING OTHER
CARRIER ANTENNAS
EXISTING SPRINT
HYBRID CABLE ROUTE
INSIDE MONOPOLE
EXISTING 85'-0"
AGL MONOPOLE
EXISTING SPRINT
ICE BRIDGE
EXISTING SPRINT
EQUIPMENT CABINETS
E7051114G CHAIN
LINK FENCE
GRADE (445'
PROPOSED EAST ELEVATION 1 2
a
c�
r^
z
a
z
z
z
s
w
w
�
z
J
o
z
a
z
o
z
rn
z
0
a
Qa
w
I
z
M
zv�i
o
I
a
a ran
O
w
N
I tv
s9
2—
m z
O
A
a
is
-
0
0
P
a
O
w
w
U
6
K
GRr
GHTNING ROD
PRINT 190OMHz ANTENNA
CTOR, 3 TOTAL)
PRINT 190OMHz RRH
BEHIND ANTENNA
:CTOR, 3 TOTAL)
THEIR
VTENNAS
PRINT
BILE ROUTE
40POLE
5'-0"
POLE
,PRINT
PRINT
CABINETS
:HAIN
E
l X -)
GHTNING ROD
SPRINT
TEN NA MOUNTED e
IG MOUNT 7
CTOR, 3 TOTAL)
SPRINT
H MOUNTED 5
TEN NA _7
CTOR, 3 TOTAL)
PRINT 190OMHz ANTENNA
CTOR. 3 TOTAL)
PRINT 1900MHz RRH
BEHIND ANTENNA
CTOR. 3 TOTAL)
AL ANALYSIS MUST BE
:D ON ALL ROOFTOPS,
AND TOWER SITES
ISTALLATION OF NEW
NEW RRH UNITS. & NEW
TEMPORARY PLATFORM.
TO BE PERFORMED BY
:D STRUCTURAL ENGINEER.
THEIR
YTENNAS
PRINT
BLE ROUTE
40POLE
5'-0"
POLE
;PRINT
;PRINT
F CABINETS
:RAIN
:E
24"x36" SCALE: 3/16" = 1'-0" EXISTING NORTH ELEVATION 1 24"x36" SCALE: 3/16" = 1'-0" �� PROPOSED NORTH ELEVATION 2
11N17" SCALE: 3/32" = 1'-O" 1 p 0 4' 11 "x17" SCALE: 3/32" = 1'-0" 4' 2' 0 4
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUViON DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHO, RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED.
Sprint
C(( D N
-rc
,a Vi11[ 11AL99OU >r cerlcs.. LLc
111 S JACKSON ST. 2ND FLOOR
SEATTLE. WA 98104
PROJECT INFORMATION:
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE 02-25-14
ISSUED FOR- CONSTRUCTION DWGS
REVISIONS
REV,
DATE
omFwSIl71i
INITIALS
A
]1/29/14
ISSUED FOR 90% CONSTRUCTION
AF
0
02/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072FEKED
T T
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN. 02-18+ s
SHEET TITLE
EXISTING & PROPOSED
NORTH ELEVATION
SHEETNUMDER
A-6-
REVISION:
0
.SE63XC32a
PANEL ANTENNA WITH
MOUNTING HARDWARE
ANTENNA PIPE
MOUNT, SAMSUNG OR
APPROVED EQUAL —
RRH MOUNTING
HARDWARE, SAMSUNG
OR APPROVED EQUAL
EXISTING
MOUNTING FRAME —
NOTE:
VERIFY EXISTING CONDITIONS —
ALL MOUNTING CLAMPS AND
HARDWARE SHALL BE VERIFIED BY
TOWER ACCESSORY MANUFACTURER
—MOUNTING PIPE
(LENGTH TO SUIT)
— 2.5 GH2 RRH
FIBER &
POWER CABLES
FIBER &
POWER
CABLES
FROM RF
CABINET
FIBER
FOWEii
FIBER & POWER
CYLINDERS.
CONTRACTOR
SHALL MOUNT WITH
ADEQUATE HARDWARE
TO EXISTING FRAME.
JUMPER (TYP.)
MANUFACTURER: KMW COMMUNICATIONS
MODEL: ET—X—WM-18-65IF, (2.5GH2)
WEIGHT: 36.4 LBS
DIMENSIONS (LxWxD): 61.0" X 12.0" X 4.3"
FREQUENCY: REFER TO RF DATA SHEET
72-0 12.0
or i
TOP Itm ?I
RF CONNECTOR, TYP —
REMOTE ELECTRICAL
DOWNTILT ACTUATOR,
MECHANICAL
DOWNTILT
aae11— 4.3
i.1 Facp7Ey
prrLp�p
to
30
Lack
SkM
RVA F_
CPYPl.N[J
ws • aP.
A�ti
rZ sle►erq>
<i2
� ,oxrNrA.
&radEltraDapedlwf 4
moo dM6c. m ]P[Yh
ArN s
sB[48dF ' 8[rstrar+��i
pill
22"x34" SCALE: NOT TO SCALE j 22'x34" SCALE: NOT TO SCALE 22"x34' SCALE: NOT TO SCALE 22' 4' SCALE: NOT TO SCALE i)
11"x17" SCALE: NOT TO SCALE MOUNTING DIAGRAM 1 11N17" SCALE: NOT TO SCALE 2.SGHZ ANTENNA 2 11x17" SCALE: NOT TO SCALE FIBER JUNCTION CYLINDER 3 11"x17" SCALE: NOT TO SCALE POWER JUNCTION CYLINDER i
MOUNTING BRACKET 153
AND HARDWARE —
SAMSUNG OR
APPROVED EQUAL
MECHANICAL 5ff.Qw'uohs-
ANTENNA
MOUNTING PIPE HxWxD: 382x584x240mm
ANTENNA (18:6' x15,5"x9.45") n;
MOUNTING PIPE}E ...jllll
WEIGHT: 59.5 LBS
MOUNTING BRACKET nlll
AND HARDWARE — i}I �IP�14�lllllil1l �Illiii111111
SAMSUNG OR 9.45 PLAN
APPROVED EQUAL
F°°
y4 O o
7
O
2
K
0 OJ
W
a
MOUNTING BRACKET
AND HARDWARE —
SAMSUNG OR Lull la Eau 2;10
APPROVED EQUAL
13
ANTENNA
MOUNTING PIPE SIDE FRONT
22"x34" SCALE: NOT TO SCALE RRH MOUNTING 4 22"x34" SCALE: NOT TO SCALE 2.5GHZ RRH-V3 5
11N17" SCALE: NOT TO SCALE 11 "x17" SCALE: NOT TO SCALE
EQUIPMENT RF—ANTENNA
UADU
5) CPRI CABLE
4) FIBER AND DC
POWER CABLES
JUNCTION 6) JCABLE
CYLINDERS
I 7) RF JUMPERS �
FEEDER LINE GROUND CABLE
3) RRH GROUND CABLE (GROUND
GROU DKI OR/8IN.
FEEDEMGB
1) MGB GROUND CABLE
TGB AND GROUND KIT ARE USED IN CASE
OF THE 7/8 N. FEEDER LINE OR MORE
22"x34" SCALE: NOT TO SCALE 22`x3eSCALE: NOT TO SCALE NOT USED
11 N17" SCALE: NOT TO SCALE SAMSUNG MMBS WRING DIAGRAM 6 11"x 17" SCALE: NOT TO SCALE
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROH18TTE0.
Spri nt):o�
m RN
=-ramPA,CIF[C TELECOM VICES, C
111 S JACKSON ST, 2ND FLOOR
SEATTLE, WA 90104
PROJECT INFORMATION:
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY. WA 98003
KING COUNTY
ISSUE DATE- 02-25-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
R(V. I
DATE
13ESCf1vr1 N
[1xILL'S
A 101/29/14
ISSUED FOR 90% CONSTRUCTION
AF
0
2/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4D7�TISTERED
CHITT
THO S R. HOLLAND
STATE OF WASHINGTON
REN. 02.18-1 �
willillsoo
SHEET TITLE:
EQUIPMENT DETAILS
SHEETNUMBER:
A-7
REVISION:
0
E63XC32
TYPICAL HYBRID CABLE COLOR CODE
SECTOR
FIRST RING
SECOND RING
THIRD RING
A
GREEN
NO TAPE
NO TAPE
B
GREEN
GREEN
NO TAPE
G
GREEN
GREEN
GREEN
FREQUENCY COLOR CODE FOR PAIRS
AND FIBER CABLES OF HYBRID CABLE
FREQUENCY COLOR CODE
FIRST RING
SECOND RING
1900 MHz
YELLOW
I RED
TYPICAL JUMPER CABLE COLOR CODE
FREQUENCY
ANTENNA PORT
RRU PORT
CABLE
COLOR
1900 MHz
PCS1 -45'
ANT 0
BLUE
PCS1 +45'
ANT 1
WHITE
PCS2 -45'
ANT 2
GREEN
PC32 +45'
ANT 3
BROWN
RET
RET
RED
NOTES:
ON HIGH CAPACITY SITES OR ON FOUR -SECTOR SITES NEEDING AN ADDITIONAL LINE AND RRU
CONTACT GDIT SITE SUPERVISOR FOR COLOR CODE INFORMATION ON ADDITIONAL LINES.
SL, _cR
SAMSUNG FIBEROPTICS
ASIA TAI
LENGTHI
TOTAL WEIGHT
WEIGHT
LF
TOTAL WEIGHT
LF
TYPE
FT
G
LBS
KG
LBS
KG
S
KG
LBS
60
13
26
0.2
0.5
19
41
0.3
0.7
TYPE 1
75
16
35
0.2
0.5
22
49
0.3
0.7
90
19
42
0.2
0.5
26
57
0.3
0.7
105
30
66
0.3
0.6
29
65
0.3
0.7
120
34
75
0.3
0.6
33
73
0.3
0.7
TYPE a
135
38
85
0.3
0.6
46
101
0.3
0.7
150
43
94
0.3
0.6
51
112
0.3
0.7
165
47
104
0.3
0.6
55
122
0.3
0.7
180
69
151
0.4
0.8
72
160
0.3
0.7
TYPE 3
195
75
164
0.4
0.8
78
173
0.3
0.7
210
80
177
0.4
0.8
85
187
0.3
0.7
225
89
196
0.4
0.9
102
224
0.3
0.7
'YPE 4
240
95
209
0.4
0.9
109
239
0.3
0.7
255
101
222
0,4
0.9
1 115
254
0.3
0.7
133
293
0.5
1.1
122
270
0.3
0.7
141
310
0.5
1.1
152
335
0.3
0.7
YY
A330
148
326
0.5
1.1
160
353
E3
0.7
155
342
0.5
1.1
168
371
0.3
0.7
163
359
015
1.1
176
38B
TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 TYPE 7
TOTAL LENGTH
"-114'-9,95"
-180'-5.35"
-213'-3.05"
-262'-5.60"
"328'-1"
-420'-0'
-550'-D"
HYBRID POWER
AWG 10 1 PAIR,
AWG 8 1 PAIR,
AWG 6 1 PAIR,
AWG 6 1 PAIR,
AWG 4 1 PAIR,
AWG 4 1 PAIR,
AWG 2 1 PAIR,
CABLE
AWG 12 3 PAIR
AWG 10 3 PAIR
AWG 8 1 PAIR,
AWG 8 3 PAIR
AWG 6 1 PAIR,
AWG 6 3 PAIR
AWG 4 3 PAIR
CONFIGURATION
AWG 10 2 PAIR
AWG 8 2 PAIR
CABLE DIAMETER
0.98"
1.06"
1.18"
1.18"/1.25"
1.25"
L56"
1.69"
BENDING RADIUS
11.61"
12.99"
15.35'
17.71'
17.71"
18.00"/30.00'
21.00"/35.00"
OPTIC CABLE
LC/PC-L9-LC/PC, SINGLE MODE
DU CABINET
2 PAIR POWER AND OPTIC CABLE WITH PE PIPE
(POWER CABLE
TERMINAL MAX
SIZE AWG 4)
RRU POWER
AWG 8, 0.57"-0.60"
8 AWG CABLES 4 PAIRS
CABLE SPEC
AWC 10, 145"-0.48-
NON USE POWER
2 PAIR POWER
2 PAIR POWER 2 PAIR POWER
2 PAIR POWER
2 PAIR POWER
2 PR6i POWER
AND OPTIC CABLE
O OPTIC
.AND OPTIC CAB AND OPTIC CABL
.AND OPTIC CAB
AND OPTIC CABL
'D On, CA8
PROTECTION
WI111 PE PIPE
I WITH PE PIPE WITH PE PIPE
WffH PE PIPE
WITH PE PIPE
WITH PE PIPE
SUPPLIER
TESSC0
TYPE
LENGTH
TOTAL WEIGHT
F7
KG
LBS
TYPE 8
1
0.73
1.6
1000
732
1613
420
402
887
TYPE 7
1
1
2.2
1000
1006
2218
550
553
1220
22"x34" SCALE: NOT TO SCALE HYBRID AND JUMPER CABLES COLOR CODING 1 22 x34" SCALE: NOT TO SCALE - HYBRID CABLE TYPES 2
11"x17" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE
(4) PAIR
TO RRU
2" TAPE 2" TAPE 2" SPACE
SECOND RING THIRD RING BETWEEN HYBRID 2" TAPE 2" TAPE
2" TAPE 1" SPACE IF APPLICABLE PER 1 SPACE IF APPLICABLE PER CABLE COLOR CODE FIRST RING SECOND RING
FIRST RING BETWEEN ( BETWEEN ( AND FREQUENCY FREQUENCY COLOR FREQUENCY COLOR
HYBRID COLOR CODE , RINGS SECTOR) RINGS SECTOR) COLOR CODE CODE , CODE
(6) FIBER CABLES
HYBRID COLOR CODE HYBRID COLOR CODE
TAPE (SEE TABLE TAPE [SEE TABLE
NO SPACE
FREQUENCY COLOR
HYBRID COLOR. CODE
FOR DETAILS) FOR
pETA1LS)
BETWEEN
CABLE
CODE (SEE TABLE
TAPE (SEE TABLE
FOR DETAILS)
FOR DETAILS)
2" TAPE
2" TAPE
2" SPACE
BETWEEN HYBRID
2" TAPE
2" TAPE
2" TAPE
1" SPACE SECOND RING
1" SPACE THIRD RING
CABLE COLOR CODE
FIRST RING
SECOND RING
FIRST RING
BETWEEN ( IF APPLICABLE PER
BETWEEN ( IF APPLICABLE PER
AND FREQUENCY
FREQUENCY COLOR
FREQUENCY COLOR
HYBRID COLOR
CODE RINGS SECTOR)
RINGS SECTOR)
COLOR CODE
CODE
CODE
(4) PAIR COPPER
111
TO CABINET
(6) FIBER CABLES
HYBRID COLOR CODE HYBRID COLOR CODE
HYBRID COLOR CODE TAPE (SEE TABLE TAPE (SEE TABLE
TAPE [SEE TABLE FOR DETAILS) FOR DETAILS) FOR DETAILS)
NOTE:
1. ALL CABLES SHALL BE MARKED AT THE TOP AND BOTTOM WITH 2" COLORED TAPE OR STENCIL TAG,
COLOR TAPE SHALL BE OBTAINED FROM GRAYBAR ELECTRIC.
2. THE FIRST RING SHALL E CLOSEST TO THE END OF THE CABLE AND SPACED APPROXIMATELY 2"
FROM AN END CONNECTOR, WEATHERPROOFING, OR BREAK-OUT CYLINDER, WITH 1" SPACE BETWEEN
EACH RING.
3. THE HYBRID CABLE COLOR SHALL BE APPLIED IN ACCORDANCE WITH THE "TYPICAL HYBRID CABLE
COLOR CoDE" TABLE ABOVE FOR THE RESPECTIVE SECTOR.
4. INDIVIDUAL POWER PAIRS AND FIBER CABLES SHALL BE LABELED WITH BOTH THE HYBRID CABLE
COLOR FOR THE RESPECTIVE SECTOR AND A FREQUENCY COLOR CODE IN ACCORDANCE WITH THE
"FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE" TABLE ABOVE.
5, A 2" GAP SHALL SEPARATE THE HYBRID CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE.
6. THE 2" COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO
SPACES.
7. THE 2' COLORED TAPE(S) SHALL EACH BE WRAPPED A MINIMUM OF 3 TIMES AROUND THE HYBRID
CABLE OR INDIVIDUAL CABLES, AND THE TAPE SHALL BE KEPT IN THE SAME LOCATION AS MUCH AS
POSSIBLE.
8, COLOR BAND ON JUMPERS SHALL BE 2" WIDE WITH A 2" SPACE
NO SPACE J �- FREQUENCY COLOR
BETWEEN CABLE CODE (SEE TABLE
FOR DETAILS)
2" SPACE
FROM END OF 2" TAPE RING
BREAK-OUT CYLINDER . FIRST RING
2" TAPE RING 2" TAPE RING
1" SPACE SECOND RING 1' SPACE THIRD RING
BETWEEN (IF APPLICABLE PER BETWEEN (IF APPLICABLE PER
RINGS SECTOR) RINGS SECTOR)
HYBRID COLOR CODE HYBRID COLOR CODE WRAP TAPE AROUND
TAPE (SEE TABLE TAPE (SEE TABLE CABLE THREE TIMES,
FOR DETALS) FOR DETAILS) MIN. (TP) HYBRID CABLE
TO CABINET
2" TAPE RING 2" TAPE RING
2" SPACE 1" SPACE SECOND RING 1' SPACE THIRD RING
FROM END OF 2" TAPE RING BETWEEN (IF APPLICABLE PER BETWEEN(IF APPLICABLE PER
BREAK-OUT CYLINDER, FIRST RING RINGS SECTOR) RINGS SECTOR)
HYBRID COLOR CODE
TAPE (SEE TABLE
HYBRID OR CODE
TAPE (SEE TABLE
WRAP TAPE AROUND
CABLE. THREE TIMES,
FOR DETALS)
FOR DETAILS)
MIN. (TYP)
2' TAPE
2' TAPE
2' SPACE
SECOND RING
FIRST RING
BETWEEN CABLE COOE
FREOU NCY COLOR
FREQUENCY COLOR
AND FREQUENCY
CODE
CODE
COLOR CODE
HYBRID CABLE
TO RRU -
2" TAPE
THIRD RING
CABLE A t' SPACE
2 FROM RRU ANTENNA END
OF JUMPER
2" SPACE
2" TAPE
2" TAPE
2" TAPE
BETWEEN CABLE CODE
FIRST RING
SECOND RING
THIRD RING
AND FREQUENCY
FREQUENCY COLOR
FREQUENCY COLOR
CABLE y
COLOR CODE
CpOE
CODE
RRU & END
FROM ANTENNA
OF JUMPER
JUMPERTEN I N AT RRU AND ANTIFININA
22"x34" 3
HYBRID CABLE COLOR SCHEME DE -TAIL
11"x17" SCALE: NOT TO SCALE SCALE: NOT TO SCALE
THE INFORMATION CONTALNED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED,
Sprint
1
C(m YL�
p4ClE IC TELECOM RVIC ES, LLC
111 5 JACKSON ST, E2ND FLOOR
SEATTLE. WA 95104
PROJECT INFORLMATION:
JEFFR.IES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUEDTTE 02-25-14
ISSUED FORzCONSTRUCTION DWGS
REVISIONS
REV.
DATE
DESCRIPTION
INITq S
A
01/29/14
ISSUED FOR 90% CONSTRUCTION
AF
p
)2/25/14
ISSUED FOR 100% CONSTRUCTION
GAP
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
07REGISTERED
ART
ZT,11OMAS R. HOLLAND
TE OF WASHINGTON
REN. 02.181 r _ l
� l
SHEET TITLE
ANTENNA AND CABLE
COLOR CODING DETAILS
SHEETNUMBER
R-F-1
EE63XC,32
1
CONNECTION FROM EXISTING
SPRINT ANTENNA GROUND BARS
TO EXISTING MASTER GROUND BAR
CONNECTION OF SPRINT ANTENNA
MOUNTING PIPE TO EXISTING
ANTENNA GROUND BAR
(1 PER SECTOR, 3 TOTAL)
CONNECTION OF SPRINT RRU
TO EXISTING ANTENNA GROUND
BAR (1 PER SECTOR, 3 TOTAL)
LEGEND
■
EXOTHERMIC CONNECTION
f.T
MECHANICAL CONNECTION
COMPRESSION CONNECTION
CGB
COLLECTOR GROUND BAR
MGB
EXTERNAL GROUND BAR
24"x36" SCALE: 1/2" = 1'-O'
11"x17" SCALE: 1/4' - 1'-0'
NOT LISED 2
CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
EXISTING FINAL GROUND LEAD FROM
MASTER GROUND BAR TO EXISTING
MONOPOLE GROUND RING
EXISTING SPRINT MASTER
GROUND BAR AT GROUND LEVEL
EXISTING SPRINT
ANTENNA GROUND BAR
(1 PER SECTOR, 3 TOTAL)
TRUE UAcryiR:
e .mw #*M
a�
ANTENNA SCHEMATIC GROUNDING PLAN I 1
NOT USED 1 3
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION
AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER
METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO
SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS
MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS.
GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR
POLE USING MFR'S PRACTICES.
3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. ALL WIRES
SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE
GREEN INSULATED WIRE ABOVE GROUND,
4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE
GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED
BY SPRINT WIRELESS REPRESENTATIVE.
5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL
PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING
STANDARDS.
6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF
GROUNDING SYSTEM PER SPRINT STANDARD GROUNDING METHOD,
AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT
WIRELESS REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING
SYSTEM. PHOTO DOCUMENT ALL EXOTHERMIC AND GROUND RING
7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES
INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS.
& ALL EXITING GROUND BARS, WIRES ✓4 CONNECTIONS SHALL BE
FIELD VERIFIED. ANY DEFICIENT ITEMS SAkl L BE REPLACED AS
REQUIRED TO ACHIEVE ADEQUATE GROUNDING REQUIRED BY SPRINT.
I GENERAL GROUNDING NOTES
GROUNDING NOTES
1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID COPPER
CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED
GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD.
2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN
EACH SECTION AND LABEL EACH SECTION ('P". "A", 'N", "I-) WITH
1" HIGH LETTERS
3 ALL HARDWARE 16-3 STAINLESS STEEL, INCLUDING LOCK
WASHERS, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND
BEFORE MATING. ALL HARDWARE SKALL BE STAINLESS STEEL 3/6
INCH DIAMETER OR LARGER.
4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT
WASHER BETWEEN LUG AND STEEL. COAT ALL SURFACES WITH AN
AND -OXIDANT COMPOUND BEFORE MATING
5. NUT & WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE
GROUNDING BAR AND BOLTED ON THE BACK SIDE. INSTALL BLACK
HEAT -SHRINKING TUBE, 600 VOLT INSULATION ON ALL GROUNDING
TERMINATIONS, THE INTENT IS TO WEATHERPROOF THE
COMPRESSION CONNECTION.
& NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE
TYPE OF TOWER. ANTENNA LOCATION, AND CONNECTION
ORIENTATION PROVIDE AS REQUIRED.
7. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED
OR RECOMMENDED BY CABLE MANUFACTURER.
& WEATHERPROOFING SHALL BE TYPE AND PART NUMBER AS
SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.
9, SUPPLIED AND INSTALLED BY CONTRACTOR
10. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A
GROUNDING BAR TO AN EXISTING TOWER. THE SUBCONTRACTOR
SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO
MOUNTING THE GROUNDING BAR TO THE TOWER.
11. EXTEND TWO (2) 2 AWG TINNED CU CONDUCTOR FROM BURIED
GROUNDING RING AND CONNECT TO THE NEW TOWER. FOLLOW
MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS
TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY,)
12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE
TYPE OF TOWER, ANTENNA LOCATION. AND CONNECTION
ORIENTATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR
INSTALLING ADDITIONAL GROUNDING BARS AS REQUIRED, PROVIDING
50% SPARE CONNECTION POINTS
13. EXPOSED GROUND WIRES TO BE NON METALLIC LIQUID TIGHT,
CARRIER SERVICES IS STRICTLY
ANTENNA $ECiOR I
EXISTING PROPOSED
1900 MHz 2.5 GHz
ANTENNA ANTENNA
EXIST. CGE1
I
HYBRID CABLE INTERNAL
GRID WIRE TO BE
TRIMMED TO FIT AND
ATTACHED TO GRID BAR
I
1.0 AWG R
w
.. (E)___#2 AWG
JUMPER
ANTENNA SECTOR 2
EXISTING PROPOSED
1900 MHz 2.5 GHz
ANTENNA ANTENNA
or --I Al— I
CIST. CGS
IUNCTIQN
h'LINDERS I
1
(E) HYBRID
MEDUSA
COAX JUMPER
�. �10 #,D AWG
I
HYBRID CABLE INTERNAL
GRD WIRE TO BE
TRIMMED TO FIT AND
ATTACHED TO GRD BAR
W
(E) HYBRID m
MEDUSA
(E) #2 AWG
G
U
V
[}
EXISTING UPPER rF
&
¢
TOWER GROUND BAR m
m
}
x
i
x
z
z
z
z
n
>C
W
D
z
R
W
Z
z
R
CIST. CGB _
`JUNCTIGNT
CYLINDERS I
I
_(E) #2 AWG_ _
AN NNA CiOR 3
EXISTING PROPOSED
1900 MHz 2.5 GHz
ANTENNA ANTENNA
3
a
HYBRID CABLE INTERNAL at
GRD WIRE TO BE I
TRIMMED TO FIT AND
ATTACHED TO GRD BAR
(E) HYBRID
MEDUSA
JUMPER
CYLINDERS
LEGEND
■
EXOTHERMIC CONNECTION
❑
MECHANICAL CONNECTION
o
COMPRESSION CONNECTION
CGB
COLLECTOR GROUND BAR
MGB
EXTERNAL GROUND BAR
GROUNDING NOTES
1• ALL GROUNDING CONNECMINS SHALL Be MADE SY MECHANICAL
CONNECTION, ALL CABLE TO GROUND RQOS, CROUNO RODS SP❑CES AND
LIGHTING PROTECTIONS SYSTEM AS INDICATE4. CROUTtD FOUNDATION ONLY
AS INDICATED BY PM. ALL MATERIALS USED SHALL BE INSTALLED PER
EXISTING MANUFACTURERS RECOMMENDATIONS AND PROCEDURES GROUND
EXISTING DEI EXISTING MMBS
EXISTING GPS CABINET CABINET _ CABINET HYBRID CABLE CONDUCTOR SHALL HAVE A MINIMUM 24� BENDING RADIUS
ANTENNA INTERNAL GRD WIRE 2 ALL MECHANICAL CONNECTIONS ON GALVANIZED SURFACES SHALL BE
TO BE TRIMMED TO CLEANED THOROUGHLY AND COLORED TO MATCH SURFACE WITH (2) TWO
FIT AND ATTACHED COATS OF GALVITE (WHITE) PAINT, OR SILVERBRITE (ALUMINUM)•
#6 AWG WITH TO GRD BAR
WEATHERPROOFING 3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE
— ANTIOXIDANT COMPOUND APPLIED TO CONNECTION.
_(E 2 AWG LD [D o
4. GROUND TESTS SHALL BE PERFORMED AS REQUIRED BY SPRINT
3a 3 Z 3 STANDARD PROCEDURES. GROUND GRID RESISTANCE SHALL NOT EXCEED
COAX ¢o exQ o m 5-OHMS.
rl� I3 & 5. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEXT REPORT AS
EUU85 GND BA
#2 AWG R FOLLOW:
1 2 AWG MGB G 1. ONE (1) COPY TO OWNER REPRESENTATIVE
2. ONE (1) COPY TO ENGINEER
3. ONE (1) COPY TO KEEP INSIDE EQUIPMENT INCLOSURE
ISTINO LOWER 6. ALL RADIO EQUIPMENT AND UTILITY CABINETS GROUNDS LEADS TO BE #2
TOWER GROUND BAR AWG STRANDED GREEN JACKETED FROM BUSS TERMINAL
I
I I I I 7. ALL ANTENNA MOUNT GROUNDS SHALL BE #2 AWG STRANDED GREEN
JACKETED CABLE GROUNDS SHALL BE BLACK FROM MFR
? I 8. ALL GROUND
WIRES GROUND BARS TO GROUND SHALL BE #2 AWG
SOLID AS REQUIRED.
0
01 9. ALL ABOVE GROUND WIRES SHALL BE GREEN JACKETED. ALL GROUND
¢I 2 AWC WIRE'S PENETRATING INTO GROUND AND BELOW SHALL BE SOLID BARE
cD
TOWER GROUNDING STAN6ARD
x 1 1. EXISTING HOME RUN GROUND WIRES TO BE REMOVED.
2. ALL EXISTING AND EXISTING TOWER GROUND BARS TO BE MECHANICALLY
ATTACHED TO TOWER WITHOUT INSULATORS
EXISTING #2 AG #2 AG
GROUNDS TO EXISTING GROUNDS TO EXISTING 3, NO DRILLING OR WELDING TO TOWER PERMITTED.
GROUNDS TO �X�STINGGROUND RING GROUND RING
122"x34" SCALE: NOT TO SCALE
11x17" SCALE: NOT TO SCALE
THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE- ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES 19 STRK.°RY PROHIBITED.
GROUNDING RISER DIAGRAM I 1
Sprint
-LIO N
CIS L E
F=-rES
IACIi1C TELEC 41 ICES, i C
111 S JACKSON ST, E2ND FLOOR
SEATTLE, WA 9B104
PROJECT INFORNLAMON
JEFFRIES
SE63XC320/
CROWN 880427
29205 18TH AVE S
FEDERAL WAY, WA 98003
KING COUNTY
ISSUE DATE 02-25-14
ISSUED FOR: CONSTRUCTION DWGS
REVISIONS
[REV. DATE DESCRIPTION IGA
1/29/14 ISSUED FOR 90% CONSTRUCTION .t250 4 ISSUED FOR 1007 CONSTRUCTION
NOT FOR CONSTRUCTION UNLESS
LABELED AS CONSTRUCTION SET
LICENSURE
4072 E�EGISTERED
ARCHIT CT
THOMAS R. HOLLAND
STATE OF WASHINGTON
REN,-0- ION _ l
SHEET TITLE
GROUNDING DETAILS
SHEETNUMBER: REVISION:
0
E-2
E63XC32
N►.
22'x34' SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
22"x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
22'x34' SCALE: NOT TO SCALE
11"x17" SCALEr NOT TO SCALE
IE INFORWaTION CONTAINED IN THIS SET OF
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS
DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR.
2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER
AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.)
TO ANTENNAS
RXO
CONNECTOR
WEATHERPROOFING
KIT j7YP.)
SEE ROTE 2�
#2 AWG STRANDED.
INSULATED BONDEQ
TO TOWER STEEL
OR MCNOPOLE—
NOT LISED 1 22 x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
/ KIT (TYP.)
/ STANDARD GROUND
KIT (TYP.) (SEE
DEF/3 E-5)
ANTENNA CABLE
TO SHELTER (TYP.)
�M AENNA GROUND
AWG W. SWILAR TO
106-057. MOUNT
GROUND BAR NEAR
TOP OF MONOPOLE,
TOWER OR WAVEWME
LADDER.
12
ANTENNA CABLE
WEATHERPROOFING KIT �2 1/2"0 MAX.
(SEE NOTE 3)
CABLE GROUND KIT
#6 AWG STRANDED COPPER GROUND
WIRE (GROUNDED TO GROUND BAR)
(SEE NOTE 1 & 2)
CQNNE TC N OF CABLE (;ROUND KIT TO
ANTENNA CABLE
NOTES:
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS
DIRECT GROUND WIRE DOWN TO GROUND BAR.
2. GROUNDING KR SHALL BE ANDREW SUREGROUND TYPE KIT WITH
TWO —HOLE LUG.
3, WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING
TAPE KIT, COLD SHRINK SHALL NOT BE USED.
INSPECTION
WINDOW
REQUIRED FOR BUTT CONDUCTOR
ALL INTERIOR INSULATION UP
tpm TWO —HOLE AGAINST THE
4EAD CONNECTORS
CONNECTOR
7RRf7x1' MIN
O4
FLKrT
22"x34' SCALE: NOT TO SCALE 22x34" SCALE: NOT TO SCALE
ANTENNA GROLIND BAR 2. 1"xl7" SCALE: NOT TO SCALE CABLE GROUNDING 131 ll"xl7" SCALE: NOT TO SCALE
STRANDED CU WIRE WITH GREEN,
60OV, THHN/THWN INSULATION.
SIZE AS SPECIFIED
GROUND BAR ON
ANTENNA TOWER
O O O
D a 0
O O O
TWO —HOLE LUG, BOLTED TO
GROUND BAR USING 3/8"-16 x 1
1/4'5TA1NLE55 STEEL liE% HEAD
BOLTS AND HARDWARE,
TYPICAL MECHANICAL CONNECTIONS 15 22 x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
STRANDED CU WIRE WITH GREEN,
60OV, THHN/THWN INSULATION.
SIZE AS SPECIFIED
#6 AWG GREEN STRANDED
CU GROUNDING CONDUCTOR
FROM RRU UNIT TO #2 AWG
GROUNDING CONDUCTOR � ri T`1 T-1
GROUND BAR ON
WALL, FLOOR OR ON
ANTENNA TOWER —
THIN WALL C—TAP Wj
DYE INDEX (SEE NOV
#2 AWG STRANDED C
GROUNDING CONDUCTOR
NOTE,
CONTRACTOR TO SURROUND COMPLETED
CONNECTION W/ WEATHER PROOFING TAPE TO
ENSURE WEATHER PROOF CONNECTION.
GROUND LEADS TO NEW PIPE MOUNT, NEW
SPRINT ANTENNAS & NEW SPRINT RRU'S
COAX CABLE
GROUND LEADS
O O O O EXISTING 4"xl2"xl/4" THK.,
O Q O O TINNED GROUND BAR &
CONNECTIONS.
O O O
O O O O
EXOTHERMIC WELD WITH #2 AWG SOLID TINNED
BARE CU WIRE OR STRANDED CU WIRE WITH
GREEN, 60OV, THHN/THWN INSULATION TO MGB
GROUND LEADS TO EACH
ANTENNA GROUND BAR
CLEAR IASKT/
SHRINK
TINNED COPPER
GROUNDING BAR
S/S FLAT WASHER
S/S BOLT (1 OF 2)
"DO NOT
DISCONNECT' TAG
ON ALL GROUND
BAR INTERCONNECTS
AND EQUALIZERS —
1/4" MIN
HEAT
SHRINK
TWO HOLE LLIG 1 4
NOTE:
.PROVIDE NO—OX GREASE AT CONTACT
SURFACE BETWEEN LUG AND GROUND BAR
ANTENNA GROUND BAR CONNECTIONS 6
NOTE:
•PROVIDE NO—OX GREASE AT CONTACT
SURFACE BETWEEN LUG AND GROUND BAR
COAX CABLE
GROUND LEADS
• LINNI•, • • • • • •• • • • • • • •1 • • • • • • • • • • • • •• • • • • • • • • • • • •• • • • • • • • • • • • • • • • •
22"x34" SCALE: NOT TO SCALE Q 22"x34" SCALE: NOT TO SCALE
NOT USED 7 "x17" SCALE: NOT TO SCALE C-TAP CONNECTION O "x17" SCALE: NOT TO SCALE
DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SCR l IS STRICTLY PROHIBITED.
L TWO —HOLE LUG, BOLTED TO
GROUND BAR USING 3/8"-16 x 1
1/4-STAINLESS STEEL HEX HEAD
BOLTS AND HARDWARE.
EXOTHERMIC WELD WITH #2 AWG SOLID TINNED
BARE CU WIRE OR STRANDED CU WIRE WITH GREEN,
50OV, THHN/THWN INSULATION TO ANTENNA
STRUCTURE, BUILDING, RING GROUND OR MGB
EXISTING GROUND BAR
& CONNECTIONS
' GROUND BARS AT BOTTOM
OF TOWERS OR MONOPOLES
SHALL USE EXOTHERMIC
CONNECTION.
TOWER MASTER GROUND BAR CONNECTIONS 9