Loading...
14-102712CITY OF Federal June 24, 2014 Ronald Meckler Crown Castle 8432 154`h Avenue Redmond, WA 98052 CITY HALL FILE �� 33325 8th Avenue South Federal Way, WA 98003-5325 (253) 835-7000 www. cityoffederalway, com RE: Permit #14.102712-00-UP; SPRINT SE63XC320 2920518"' Avenue South, Federal Way Dear Mr. Meckler: The City of Federal Way's Community Development department has completed use review of the proposed upgrades and additions to an existing Personan administrative land al Wireless Service Facility (PWSF) owned by Puget Sound Energy and operated by Sprint Spectrum LLC at 29205 18t' Avenue South, Federal Way, WA 98003. The proposal includes adding three antennas to the existing array with remote radio head (RRM units, Filters, and junction cylinders. The height of the existing tower will not be increased, nor will the footprint of the existing equipment compound. The Process I application was submitted and determined to be complete on June 10, 2014. Your proposal is found to be consistent with provisions of Federal Wiry Revised Code (FWRC) Chapter 19.55, `Process I —Director's Approval,' and Chapter 19.255, `Personal Wireless Service Facilities., Your Process I proposal is hereby approved. The Process I land use approval is supported by the following statements of fact: I. Zoning & Land Use —The zoning designation for the subject property (BC) ( mmunity Bu is Cosiness zone. PWSFs are permitted in BC zones pursuant to the zoning chart found o FWRC 19. siness 2. Review Process — According to submitted materials, the applicant proposes adding three antennas, three RRH's, three filters, and six junction cylinders to the existing array. e No height increase is proposed. The addition of new antennas on an existing PWSF is subject to Process I Director's Approval pursuant to FWRC 19.15.030 `Review processes for improvements and additions to developed sites.' 3. Prioritized Locations — Applicant proposes PWSF improvements in "existing broadcast, relay, and transmission towers" or the second prioritized location set forth in FWRC 19.255.010(4). The highest prioritized location is not feasible as this proposal is an upgrade to an existing facility. Staff fads the applicant has met the burden to utilize the second prioritized Iocation. The addition of three antennas should provide the full benefit of service to the area. 4. Cumulative Effects —The City must consider the cumulative visual effects of PWSFs mounted on existing structures and/or located on a given permitted site in determining whether additional perm its may be granted so as to not adversely affect the visual character of the City. As shown t the site plan Mr. Meckler June 24, 2014 Page 2 the equipment and elevations, the addition of new antennas and vallinotions adve�sely affect the visual character of the ound are not a substantial increase to the existing site. The P City and there is no proposed height increase. er 5. Facilities — The proposed facility exceeds microcell and e iFoWRCilitY t r sholds for th fanner of antennas defined in FWRC 19-05.130, `M definitions exceeding such thresholds may be permitted i A adverse $tC) the numberf antennas aand �their size equipment cabinets meet adopted development are appropriate for the location, surrounding enviro of the FWRC Thep proposal ispotential visual scon ssteent with PWSF shall comply with all other applicable standards this code section. in three I�ftH's, three filters, and six Ju ction t enclosure area. Proposed upgrades will occur ers 6. Exempt Activity —Applicant proposes c►tr on an existing monopole structure whin no exteriothe r Therefore, these changes are exempt ti within the existing fenced area resulting itted outright with no further from PWSF standards set forth in FWRC Chapter 19.255 and are perm zoning compliance required pursuant to FWRC 19.255.010(3)(9) 7. State Environmental Policy Act (SEPA) — The proposed improvements are exempt from State Environmental Policy Act review as the scope of work al of equipment for eplatcementt of existing 800(25)(a)(i): the collocation of new equipment, e the physical equipment on existing or replacement structures that does not substantially Chang p y diYnerlSlQr1S of 511C11 structures. eet Process 1 purpose criteria set forth in 8. Process I Thresholds — The proposed improvements m FWRC 19 55.020 and 19.15.030; including compliancea with applicable provisions of FWRC Title 19 `Zoning and Development' and health, safety, and PEkmff issuANu, REQuIRED Prior to any site work, the applicant shall obtain a building and electrical permit fromplease contact Building Department. For further informationtcegarding offend lg r.el or2 3�835 26 7. department's pertriit center at CLOSINGWay codes, policis, d standards This decision shall not waive compliance with futureCity ofdemo al of a building ore electrical permit.relating to this site. This Process I approval does n ot constitute The effective date of this decision is June 27, 2014, or three days from the date of this letter. Pursuant to The 1give date any person who received notice of this administrative decision may appeal the decision Examiner by July 8, 2014. Any appeal must be in the form of a letter to the Federal Way Hearing t tt delivered to the Department of Community Developmentand a y-tatetnentestablished the alleged errors in the er mus contain a clear reference to the matter being appealed Director's decision. No work on the proposal can commence until the end of the appeal period. In that you are the only party of record, your appeal period is waived (assuming you do not wish to appeal this decision). Waiver of the right to appeal does not affect the effective date of this decision. Work on the site may not commence until you have been issued the appropriate building and electrical permit. Doc I D 65824 14-102712 Mr. Meckler June 24, 2014 Page 3 This Process I approval is valid for one year from the effective date of this decision. If no further action is taken within one year, this decision will expire. A one-year extension of time may be granted only if a written request is submitted to the City's Department of Community Development at least 30 days prior to the expiration of the decision. If you have any questions regarding this decision, please contact Planning Intern Kalon Thomas at 253- 835-2622 or kalon.thomas cQci!yof ederalway.com. Sincerely, Isaac Conlen Planning Division Manager for Patrick Doherty, Director enc: Approved Site Plan c: Kalon Thomas, Planning Intern 14-102712 Doc. I.D. 65824 R.2NO MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES J U N 10 2014 33325 8'' Avenue South CITY OF � Federal Way, WA 98003-6325 Federal Way CITY OF FEDERAL WAY 253-835-2607; Fax 253-835-2609 CDS 11111E'.CEt�'UlledLCnlllal'.Ctln1 0(D � APPLICATION NO(S) 102 712 -cc) UPI Date & /I ()/(+ Project Name Sprint 2.5 SE63XC320 JEFFRIES 880427 Property Address/Location 29201�, 18TH AVENUE, SOUTH, FEDERAL WAY, WA 98003 Parcel Number(s) 304020 065 Project Description Cell site modification — Instal.1 three (3) panel ante as three Q remote radio head_(RRH) units six 6 'unction cylindem and three 3 filters on the existing tower. 'LEASE Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA .w/Project SEPA Only Shoreline: Variance, -Conditional Use Short Subdivision Subdivision Variance: CommercialfResidential Required Information BC Zoning Designation Comprehensive Plan Designation $500.000 Value of Existing Improvements $20,000 Value of Proposed Improvements International Building Code (IBC): U Occupancy Type Applicant Name: Sprint Spectrum LLC Address: 10545 Willows Rd NE, Suite 200 City/State: Redmond, WA Zip: 98052 Phone: 206-427-5856 Fax: Email: Kevin.Foy@Sprint.com Signature: Agent (if different than Applicant) Name: Ronald Meckler, Contractor, Crown Castle USA Address: 8432 150 Ave NE, Building C City./State: Redmond, WA Zip: 98052 Phone: 425-202-0203 Fax: Email: Konald.Meckler@Comeast.net Signature: [I�y Name: Russell R Lloyd Address: P. O. Box 4203 City/State: Federal Way Zip: Phone: Fax: Email Signature: See attached Letter of Authorization Bulletin #003 —January 1, 2011 Page I of l kMandoutsNaster Land Use Application 61 YL DATE: May 23, 2014 Crown Castle Tel: 425-202-0203 Ron Meckler Mobile: 206-384-2454 8432 154th Avenue NE Fax: 425-202-2771 Redmond, WA 98052 Ronald.Meckler@crowncastle.com TO: City of Federal Way, WA Department of Planning and Environmental Regulation FROM: Ron Meckler, Real Estate Specialist Crown Castle On behalf of Sprint Spectrum LLC RE: Type I Land Use and Zoning Application Sprint 2.5 Project Site SE63XC320 JEFFRIES 880427 29205 18T" Ave S, Federal Way, WA 98003 My name is Ron Meckler and I am a contractor for Crown Castle for zoning and permitting services. Our client, Sprint Spectrum, is in the process of a national update and modernization of its wireless service. The project requires adding antennas to their existing array, adding remote radio units behind the antennas, and installing filters and junction cylinders on the existing hybrid cables.. Purpose of Request The project requires swapping out their existing antennas for new antennas, as well as updating cabinets and associated cabling at all of their existing wireless facility sites. An earlier phase of the project known as' Network Vision was completed last year when the new equipment cabinets were installed along with cables and some of the new antennas. This phase will add three more antennas with remote radio head (RRH) units, filters and junction cylinders. THE HEIGHT OF THE EXISTING TOWER WILL NOT BE INCREASED, NOR WILL THE FOOTPRINT OF THE EXISTING EQUIPMENT COMPOUND Process I Review 1. Zoning & Land Use — This is an existing 93' monopole support structure, located in a Community Business (BC) zone. Sprint is proposing to make the following improvements, as depicted in the attached Site Plan/Elevations. Sprint will be installing 3 antennas, 3 RRH's, 3 filters and 6 junction cylinders to their existing antenna array. 2. Review Process — Sprint is requesting a Type I Director's Review for improvements and additions to developed sites. 3. Prioritized Locations — This is a priority 2 location, which is an upgrade to an existing facility. 4. Cumulative Effects -- The existing WCF does not contribute to any increase in vehicular traffic in the area, does not require any water, or solid waste services. There are no negatives to the existence of this WCF operating at the current location. There will be no significant increase to the visual impact of the site. The new antennas are of similar size and shape and color of the existing antennas. There are no changes to the ground equipment configuration, arino work is proposed on the equipment cabinets. 5. Facility — The proposed modification will not and new or adverse visual impact. No new MrA cabinets are proposed. The quantity of antennas is appropriate for the location and surrou#f ng- environment, which is commercial in nature. JUN 10 2014 CITY OF FEDERAL WAY CDS 6. Exempt Activity — No changes to the ground equipment configuration are proposed. No work is proposed on the existing cabinets. 7. SEPA — The proposed improvements are exempt from the State Environmental Policy Act. The antennas are attached to an existing structure in a commercial zone that does not contain a school or residence. 8. Process I Thresholds — The proposed improvements are minor in nature and should meet the Process I purpose criteria. Please do not hesitate to contact me for any additional information or clarification Sincerely, Ronald Meckler Crown Castle USA 8432 154th Ave NE Redmond, WA 98052 Tel: 425-202-0203 Email: Ronald.Meckler@cr vncastle.com Enclosures: Master Land Use Application Process I Application King County Assessors parcel map Vicinity Map Site photograph & simulation Permitting Authority Construction Drawings (6) 11x17 Check for fees PU3"T SDUND ENERGY PERMIT FOR LOCATION OF FACILITIES SPRINT SPECTRUM — MARINE VIER' SUBSTATION — PSE - #SE63XC320 This Permit, dated as of MV -L G _ , 2004, is made by and between Puget Sound Energy, a Washington corporation ["PSE"), and Sprint Spectrum L.P., a Delaware limited partnership ("Sprint Spectrum"). PSE and Sprint Spectrum are at times referred to herein where appropriate individually as a "Party" and collectively as the "Parties". The Parties agree as follows: 1. Permit. For and in consideration of the mutual benefits to be derived therefrom, PSE hereby grants permission to Sprint Spectrum, subject to the terms and conditions of this Permit, to use the real property described in the attached Appendix 1 (the "Site"). The rights and obligations of Sprint Spectrum arising under this Permit will apply to and be binding upon Sprint Spectrum's officers, employees, agents and representatives, and its suppliers and subcontractors of any tier acting on behalf of Sprint Spectrum in connection with the performance of the Work (as defined below) or this Pen -nit (collectively, the "Support"). Sprint Spectrum shall be solely responsible for the performance, nonperformance, acts and omissions of its Support. 2. Use of the Site. Sprint Spectrum shall have the right to use the Site for the purpose of undertaking the following activities (the "Permitted Activities"): 2.1 installation, operation and maintenance of the equipment specified in the attached Appendix 2 (the "Equipment") in accordance with the site development plan attached hereto as Appendix 3 (the "Site Development Plan") and all other provisions of this Permit; and 2.2 performance of the installation, maintenance, repair, relocation, removal and other work specified in the Site Development Plan (collectively, the "Work") in accordance with the Site Development Plan and all other provisions of this Permit; and 2.3 obtaining, at Sprint Spectrum's sole cost and expense, telephone service from any utility company that provides such service to the Site, and arranging for the installation of a separate meter and main breaker, subject to PSE's right to approve the exact location of proposed utility routes and the manner of installation; and 2.4 access to and from the Site for purposes of undertaking the activities : - specified in paragraphs 2.1, 2.2 and 2.3, in accordance with the following: Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA.I23) Page 1 2.4.1 access for construction, routine maintenance and repair and other non -emergency visits shall only be during normal business hours (defined as Monday through Friday, 8 am to 6 pm) unless otherwise agreed upon by the Parties; 2.4.2 in the event of emergency, Sprint Spectrum may access the Site twenty-four (24) hours per day, seven days per week, by calling the PSE emergency telephone number set forth in paragraph 7 and requesting such access; 2.4.3 access to the Site may be by foot or motor vehicle, including trucks; and 2.4.4 access to the Site shall be subject to such reasonable conditions as may be imposed by PSE from time to time. 3. Limitations on Use. Except and only as specifically authorized in paragraph 2, Sprint Spectrum shall not enter upon the Site or make any use thereof. Without limiting the generality of the foregoing: 3.1 Sprint Spectrum shall, at all times, undertake the Permitted Activities in a manner so as to prevent bodily harm to persons (whomsoever) and damage to property (whatsoever). Precautionary measures shall include, without Iimitation, reasonable site security measures (e.g., fencing, signage, lighting, security guards, etc.) necessary to prevent access to the Site during such times as the Permitted Activities may cause the Site to be in an unsafe or unsecured condition. 3.2 Sprint Spectrum shall, at all times, undertake the Permitted Activities in a manner that does not disturb or interfere in any way with the operations of PSE or any prior existing users of the Site, or otherwise in a manner that would impair the safe, continuous and reliable operation of PSE's utility systems or improvements. Without limiting the generality of the foregoing, Sprint Spectrum shall at all times: 3.2.1 conduct the Permitted Activities so as to maintain legal and safe clearances from PSE's utility systems or improvements; 3.2.2 take all prudent precautions to ensure that no persons or property come into contact with PSE's utility systems or improvements; and 3.2.3 conduct the Permitted Activities so as to maintain access along and across the Site to PSE's utility systems and improvements, sufficient to allow the free passage of all equipment, vehicles, personnel and other items as may be necessary or convenient for the maintenance, repair and replacement of PSE's utility systems and improvements. If, at any time, the Permitted Activities shall disturb, interfere with or otherwise impair the - safe, continuous and reliable operation of PSE's utility systems or improvements, Sprint Spectrum shall immediately cease and discontinue such Permitted Activities. If Sprint Spectrum anticipates that any Permitted Activity may disturb, interfere with or otherwise Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA l23) Page 2 impair the safe, continuous and reliable operation of PSE's utility systems or improvements, Sprint Spectrum shall request in writing, not less than fourteen (14) days in advance of the date required, that PSE take such action with respect to its systems or improvements as is necessary to accommodate such Permitted Activity. PSE may elect to accommodate such Permitted Activity in response to such request; provided, however: (a) all costs and expenses incurred by PSE thereby shall be reimbursed to PSE, and (b) PSE may refuse any or all such requests or may discontinue actions undertaken in response to such requests, as PSE, in its sole discretion, may choose. 3.3 Sprint Spectrum shall not undertake any activities and shall not use or permit any use of the Site that will in any way: 3.3.1 be in noncompliance with, or otherwise conflict with, any applicable laws, regulations, ordinances, rules, orders or other requirements, now or hereafter in effect, of any governmental authority (all laws, regulations and orders required to be incorporated in agreements of this character are hereby incorporated herein by this reference); 3.3.2 cause or constitute any nuisance, noxious odors, unsafe condition or waste in or about the Site; 3.3.3 interfere with the rights or disturb the use and enjoyment of PSE, other users of the Site, or any other person lawfully on the Site; 3.3.4 cause a cancellation, increase the premiums for or deductibles under or otherwise affect any fire, casualty, property, liability or other insurance covering the Site, any activities conducted upon or from the Site, or any accident, act, error, omission, fault, negligence or strict liability occurring on or about the Site; or 3.3.5 except as otherwise provided in the Site Development Plan, cause or allow the generation, storage, processing, handling, transport, spill, disposal or release of any dangerous, hazardous or extremely hazardous material, waste or substance at, upon or in any way affecting the Site (including, but not limited to, any such materials, waste or substances subject to regulation by any federal, state or local law pertaining to the protection of human health or the environment). 3.4 Sprint Spectrum shall not, and shall not pen -nit others to, install, store, maintain or operate any equipment, fixtures, improvements, supplies, vehicles or other items on the Site except for the Equipment (which Equipment shall be installed, maintained and operated at Sprint Spectrum's sole cost, risk and expense). 3.5 Sprint Spectrum shall obtain and comply (and shall ensure that all of Sprint Spectrum's Support comply) with all permits, licenses, franchises, rights -of -way, easements and other rights required to undertake any Permitted Activity. Sprint Spectrum shall furnish to PSE such evidence thereof as PSE may request. Sprint Spectrwn SE63XC320 Marine View Substation— PSE (SEA123) Page 3 3.6 If, in PSE's reasonable judgment, the Equipment or any Permitted Activity violates, jeopardizes or unreasonably interferes with: (a) any laws, regulations, rules, orders or other regulatory authorizations, permits or approvals that may concern PSE's present or future use and enjoyment of the Site, or (b) any proprietary rights such as any contract, permit, license, franchise, right-of-way, easement or other rights of PSE, and Sprint Spectrum fails to correct the problem within thirty (30) days after written notice from PSE (or such shorter or (to the extent reasonably necessary to correct the problem) longer period of time as is expressly required or permitted under the applicable law, regulatory authorization, permit or approval or applicable proprietary right of PSE), PSE may require that Sprint Spectrum immediately remove any or all Equipment from and cease any Permitted Activity at the Site. If Sprint Spectrum fails to remove any Equipment within fifteen (15) days after PSE makes its request, PSE may remove the Equipment at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 3.7 Sprint Spectrum shall timely pay all (and shall promptly secure the discharge of any liens asserted by any) persons and entities furnishing labor, equipment, materials or other items in connection with the Permitted Activities. Sprint Spectrum shall furnish to PSE such releases of claims and -other documents as may be requested by PSE from time to time to evidence such payment (and discharge). If any such persons or entities are not timely paid (or if any of such liens are not promptly discharged), PSE may make such payments (and secure such discharge) at Sprint Spectrum's expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. Sprint Spectrum may contest the validity of any such lien provided that Sprint Spectrum delivers a bond to PSE in the amount of the contested lien. 3.8 In undertaking the Permitted Activities, Sprint Spectrum shall comply and shall ensure that all of its Support comply with all applicable industry standards and codes, and all of PSE's standard practices, specifications, rules and regulations provided by PSE to Sprint Spectrum on request. Sprint Spectrum shall furnish such documents as may be required to effect or evidence such compliance. 3.9 Sprint Spectrum shall comply with the following in connection with its performance of the Work: 3.9.1 Sprint Spectrum shall furnish all personnel, supervision, labor, transportation, tools, equipment and materials for performance of the Work. Sprint Spectrum shall expeditiously and efficiently perform the Work in accordance with the Site Development Plan and the provisions of this Permit. Sprint Spectrum shall not independently hire any PSE employee to perform any of the Work (e.g., other than in the course of his or her employment with PSE with respect to Work that PSE agrees to perform for Sprint Spectrum). 3.9.2 Sprint Spectrum shall perform the Work in a workmanlike and skillful manner. Sprint Spectrum shall ensure that the Work and the Equipment is in all respects (a) safe, (b) of first-class quality, (c) free from all faults and defects in workmanship, material and design, and (d) in confonnance with such reasonable Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 4 1 requirements and specifications as PSE shall from time to time prescribe and all laws and the regulations, orders and decrees of all lawfully constituted bodies and tribunals pertaining to the construction, operation and maintenance, including without limitation, the requirements of the latest edition of the National Electrical Safety Code. 3.9.3 Sprint Spectrum shall promptly and satisfactorily correct or replace any Work or Equipment found to be defective or not in confonnity with the requirements of this Permit. If Sprint Spectrum fails or refuses to perform any Work required by this Permit or to make any such corrections or replacements, PSE may perform such Work and make such corrections and replacements at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 3.9.4 Installation of the Equipment or the performance of other Work shall not adversely affect the structural integrity, maintenance or marketability of the Site or any structure or improvement on or surrounding the Site. 3.9.5 Sprint Spectrum shall ensure that all personnel who perform the Work shall be fully experienced and properly qualified to perform the same. Sprint Spectrum shall, if so requested by PSE, remove from performance of the Work any personnel (including, without limitation, any Support) whom PSE finds to be incompetent, careless or otherwise unsafe. 3.9.6 Sprint Spectrum hereby acknowledges that PSE employs workers covered by one or more collective bargaining agreements. In the event of any actual or potential labor dispute between PSE and its workers that is, in whole or in part, based upon or otherwise arises out of the performance of the Work or this Permit, Sprint Spectrum will cooperate with PSE and take such action as may be reasonably requested by PSE to fully and expeditiously resolve such dispute. 3.9.7 Sprint Spectrum shall, at all times, keep the Site cleared of rubbish, refuse and other debris generated by Sprint Spectrum or its Support and in a neat, clean and safe condition. Upon completion of any portion of any of the Work, Sprint Spectrum shall promptly remove all rubbish, refuse and other debris generated by Sprint Spectrum or its Support and all of its Equipment and surplus materials. 39.8 The Work and the Equipment (i.e., as it relates to the Work) shall at all times be subject to inspection and testing by PSE. Sprint Spectrum may, at its option, have a representative present at the Site during any such inspection or testing by PSE. If, in PSE's reasonable judgment, the performance of any Work requires one or more representatives of PSE to be present at the Site during the performance of such Work, then Sprint Spectrum will reimburse PSE for any and all reasonable costs and expenses thereby incurred by PSE. No inspection, test, delay or failure to inspect or test, or failure to discover any defect or non-compliance by PSE shall relieve Sprint Spectrum of any of its obligations under this Permit. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 5 3.9.9 Sprint Spectrum shall promptly settle or resolve all complaints received by Sprint Spectrum from third Parties arising out of or in connection with performance of the Work. Sprint Spectrum shall promptly notify PSE of all such complaints and any action taken (or to be taken) in connection therewith. In handling any complaints, Sprint Spectrum shall use its best efforts to maintain and promote good public relations for PSE. 3.9.10 Sprint Spectrum acknowledges and anticipates that the Work may be interfered with and delayed from time to time on account of the concurrent performance of work by PSE or others. Sprint Spectrum shall fully cooperate with PSE and others and coordinate the Work with such other work so as to minimize any delay or hindrance of any work. 3.9.11 If any part of the Work depends upon the results of other work by PSE or others, Sprint Spectrum shall, prior to commencing such Work, notify PSE in writing of any actual or apparent deficiencies or defects in such other work that render it unsuitable for performance of the Work. Failure of Sprint Spectrum to so notify PSE shall constitute an acceptance by Sprint Spectrum of such other work as suitable for performance of the Work, except as to latent defects which may subsequently be discovered in such other work. 3.10 Upon completion of Permitted Activities which may disturb the surface or subsurface of the Site (or any improvements thereon), Sprint Spectrum shall restore the Site (and any improvements thereon) to a condition as good or better then the condition the Site (or such improvements) was in prior to such disturbance. 3.11 If, in undertaking Pennitted Activities (or activities off -Site in furtherance of Permitted Activities), Sprint Spectrum shall cause significant public concern with or opposition to its proposed use of the Site, and PSE shall reasonably conclude that such public concern or opposition will materially interfere with its use of the Site or otherwise with the conduct of PSE's business, then PSE may direct Sprint Spectrum to cease and desist such acts (or omissions) giving rise to such public opposition or concern. 3.12 Sprint Spectrum shall copy PSE's T&D Planning & Analysis Department Director on all notices and other correspondence received or given by Sprint Spectrum in connection with any local jurisdiction review process involving any Permitted Activities undertaken or proposed to be undertaken by Sprint Spectrum at the Site. 4. E ui ment Structures and Facilities. 4.1 Sprint Spectrum shall maintain all Equipment on the Site in good and safe condition and in a manner that does not materially affect the structural integrity of any structure on the Site. If Sprint Spectrum fails to do any maintenance within thirty (30) days after receipt of notice from PSE requesting such maintenance, then PSE may, at its option, do such maintenance at Sprint Spectrum's expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. If Sprint Spectrum commences the requested Sprint Spectruan SE63XC320 Marine View Substation — PSE (SEA123) Page 6 maintenance within thirty (30) days after any written notice from PSE requesting such maintenance and thereafter continuously and diligently pursues and completes such maintenance, then the thirty (30) day cure period will extend for an additional sixty (60) days to permit Sprint Spectrum to complete the requested maintenance. 4.2 PSE shall at all times during the Term of this Permit, at PSE's sole cost and expense, maintain any PSE-owned structures used by Sprint Spectrum for Permitted Activities in a structurally good and safe condition. If Sprint Spectrum is unable to use such structure due to PSE's maintenance activities, Sprint Spectrum may immediately install temporary Equipment on any alternate location specified in the Site Development Plan while PSE makes repairs to the Site. 4.3 If PSE at any time relocates, replaces or removes any pole, tower or other facility or structure on which any Equipment is attached, or PSE otherwise determines in its reasonable judgment that any Equipment must be removed or relocated to accommodate PSE's use of or activities on the Site, then Sprint Spectrum shall, at its sole cost and expense, remove or relocate such Equipment at such times and in the manner directed by PSE. If Sprint Spectrum fails to remove or relocate its Equipment within one hundred eighty (180) days (or such shorter period of time as PSE may reasonably require under the circumstances) after being directed to do so by PSE, PSE may remove or relocate the Equipment at Sprint Spectrum's sole risk and expense, and Sprint Spectrum shall reimburse PSE for the entire expenses thereby incurred. 4.4 In the event Sprint Spectrum is permitted to and does install any pole, tower or other structure as part of the Equipment on the Site, PSE shall have the right, subject to such reasonable rules and requirements as the parties may agree upon in writing, to install one or more items of equipment on such pole, tower or other structure for PSE's internaf purposes only, provided that the pole, tower or structure in question is structurally capable of bearing the weight of PSE's equipment. Such installation and use shall be at PSE's cost and expense, but Sprint Spectrum shall not levy any charge or fee for PSE's use thereof. S. Nonexclusive. This Permit is nonexclusive, and PSE may grant rights to others to use the Site for any purpose not inconsistent with Sprint Spectrum's rights hereunder. PSE does not warrant title to the Site and shall not be liable for defects thereto or failure thereof. Without limiting any other provision of this Permit, Sprint Spectrum will promptly resolve technical interference problems with other radio communications equipment located at the Site on the date of this Permit or any radio communications equipment located at the Site on any future date when Sprint Spectrum modifies or supplements its Equipment at the Site. Likewise, PSE will not permit the installation of any future radio communications equipment which results in technical interference problems with Sprint Spectrum's then -existing Equipment at the Site; provided that the foregoing obligation of PSE shall only apply if and to the extent PSE is expressly entitled by contract or applicable law to prevent or reftise to permit such installation. 6. Cooperation of PSE. PSE shall, at Sprint Spectrum's expense, support Sprint Spectrum's efforts to secure any documents or applications required (i.e., by virtue of Sprint Spectrum SE63XC320 Marine View Substation —PSE (SEA123) Pagel PSE's ownership of or rights in the Site) to be obtained by Sprint Spectrum from any governmental agency with jurisdiction in order for Sprint Spectrum to obtain the necessary licenses, permits or other approvals from such governmental agency for the Permitted Activities; provided, however, that PSE shall not under any circumstances be obligated to execute any application or other document that, in PSE's sole judgment, will in any way impair, limit or adversely affect PSE's rights in or ownership or use of the Site, nor shall PSE be obligated to provide such support if the same requires a commitment of resources of any kind of a value in excess o 7. Emergencies. In the event of an emergency relating to the Equipment or the Site, Sprint Spectrum shall immediately correct any safety or use problems, even if full repair cannot be made at the time, in order to protect persons and property or to allow use of the Site. The Parties' respective emergency phone numbers are as follows: PSE: Sprint Spectrum: Each Party shall promptly notify the other of any change in such party's emergency phone number. 8. UershiD and Risk of Loss of Efluipment. 8.1 The Equipment located at the Site pursuant to the terms of this Permit will at all times be and remain the property of Sprint Spectrum and will not be subject to any lien or encumbrance created or suffered by PSE. Sprint Spectrum has the right to make such filings with the Washington State Department of Licensing (e.g., UCC-1 Financing Statement) as it deems necessary or desirable to evidence its ownership of the Equipment. Notwithstanding the foregoing, if, upon termination or expiration of the Tenn, the Equipment is not removed from the Site and the Site restored according to the terms of this Permit, such Equipment shall be deemed abandoned thirty (30) days following such termination or expiration and PSE's waiver of lien shall thereafter be void and of no further force and effect. 8.2 Sprint Spectrum shall be responsible for and shall bear any and all risk of loss, deterioration, theft, vandalism or destruction of or damage to the Equipment and anything used (or to be used or consumed) in connection with the Work. 9. Examination of Records. Sprint Spectrum shall promptly furnish PSE with such information related to the Work or the Equipment as may from time to time be reasonably requested by PSE. Until the expiration of three (3) years after the termination of the Term, PSE shall have access to and the right to examine and copy all of Sprint Spectrum's books, documents, papers and records which are related to the Work, the Equipment or this Permit. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 8 10. Compensation. 10.1 The "Annual Fee" shall mean the annual fee for Sprint Spectrum's use of the Site as calculated in accordance with the schedule set forth in the attached Appendix 4 and the following: 10.1.1 The Annual Fee will be payable on or before the date of this Permit and thereafter on the first day of the first month following each anniversary of the commencement date of the Master Agreement, and 10.1.2 The Annual Fee will be prorated in the first and Iast year of this Permit to coincide with the anniversary of the commencement date of the Master Agreement. If Sprint continues to hold any Site after the termination of the applicable Permit, whether the termination occurs by lapse of time or otherwise, such holding over will, unless otherwise agreed to by PSE in writing, constitute and be construed as a month -to -month tenancy at a monthly Fee equal to of the Annual Fee for such Permit until all of the Equipment is removed from the Site and restoration of the Site has occurred according to the provisions of this permit, and will remain subject to all of the other terms set forth in this Agreement. 10.2 PSE shall invoice Sprint Spectrum for all amounts payable by Sprint Spectrum to PSE under this Permit (including, without limitation, the Annual Fees and all reimbursable costs and expenses described elsewhere in this Pen -nit) as they become due. Sprint Spectrum shall pay each such invoice in full within thirty (30) days after Sprint Spectrum's receipt thereof. 10.3 Sprint Spectrum acknowledges that late payment of any fee or other amounts due to PSE under this Permit will cause PSE to incur certain administrative, processing accounting costs not otherwise contemplated by this Permit, the exact amount of which will be extremely difficult, if not impossible, to ascertain. Accordingly, if any fee or other amounts shall not be received by PSE within thirty (30) days after such amounts shall first become due, Sprint Spectrum shall pay to PSE a late charge, as liquidated damages and not as a penalty, equal to of such overdue amounts as a reasonable estimate of the administrative, processing and accounting costs PSE will incur by reason of late payment by Sprint Spectrum. Such late charge is intended to be in lieu of Sprint Spectrum's liability for such costs, but shall not relieve or release Sprint Spectrum from liability for any other costs or damages suffered by PSE by reason of late payment. Payment of such late charge shall in no event excuse or cure any default under or breach of this Permit by Sprint Spectrum. 10.4 In addition to any late charge levied under this Permit, Sprint Spectrum shall pay to PSE interest, compounded daily, at the rate of per month or the maximum rate permitted by applicable law, whichever is less, on any fees or other amounts not paid to PSE when due under this Permit, from the date due until the date paid. Payment Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 9 of such interest shall not excuse or cure any breach of or default under this Permit by Sprint Spectrum. 11. Taxes. Sprint Spectrum shall pay (except as otherwise required by law) all fees and taxes applicable to or incurred in connection with the Work, the Equipment or the system of which the Equipment constitutes a part. Subject to the foregoing, PSE shall pay all taxes and other fees or charges attributable to each Site (including, without limitation, debt and ground Iease obligations). 12. Site Acceptance. 12.1 Sprint Spectrum will be deemed to have accepted the Site upon execution of this Site Permit. Conducting feasibility and cost assessments or other preliminary inspections on the Site prior to execution of this Site Permit shall not be deemed to be acceptance. 12.2 Acceptance of the Site by Sprint Spectrum in accordance with paragraph 12.1 shall be conclusive evidence that Sprint Spectrum: 12.2.1 accepts the Site as suitable for the Permitted Activities; 12.2.2 accepts the Site and any structure on the Site and every part and appurtenance thereof "AS IS," "WHERE IS" and "WITH ALL FAULTS AND DEFECTS"; and 12.2.3 releases, and waives all claims against, PSE in respect of defects in the Site and its structures and appurtenances, their habitability or suitability for any permitted purposes, except as expressly provided otherwise in this Agreement. 12.3 PSE does not warrant the suitability of the Site for the purposes for which Sprint Spectrum may desire to use it (including, without limitation, the Permitted Activities); nor does PSE warrant the adequacy of the Site's location, its condition nor the condition of any structure or appurtenances for any purpose. Sprint Spectrum acknowledges that, in accepting the Site (and any and all structures thereon used by Sprint Spectrum for Permitted Activities) in its "AS IS," "WHERE IS" and "WITH ALL FAULTS AND DEFECTS" condition, PSE makes no representations or warranties whatsoever concerning the Site and/or such structures, or any aspect of their status or condition, and that Sprint Spectrum is not in any way relying on information disclosed by PSE with respect thereto, or otherwise in PSE's possession with respect thereto; rather, Sprint Spectrum is solely relying on its own inspections and assessments with respect to the condition or status of the Site and/or such structures. 13. Term and Termination. 13.1 The term of this Permit (the "Term") will commence on the date of this Permit and, unless earlier terminated as provided elsewhere in this Permit, will end upon expiration of the term of the Master A Bement. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 10 to occur: 13.2 The Term will terminate automatically upon the first of the following 13.2.1 the term of the Master Agreement at any time expires or is terminated for any reason; 13.2.2 any certificate, permit, license or approval affecting Sprint Spectrum's ability to use the Site in the manner originally intended by Sprint Spectrum is finally rejected or not likely to be obtained; or 13.2.3 any previously issued certificate, permit, license or approval affecting Sprint Spectrum's ability to use the Site is canceled, expires, lapses, or is otherwise withdrawn or tenminated by the applicable governmental agency. 13.3 PSE may at any time terminate the Tenn and all of Sprint Spectrum's rights to use the Site upon: 13.3.1 sixty (60) days' prior written notice to Sprint Spectrum if any Permitted Activity unreasonably interferes with (a) PSE's or any other prior existing user's use of the Site, or (b) access to or around the Site or any structure adjacent to the Site by PSE or any other prior existing users of PSE's property on or adjacent to the Site and Sprint Spectrum fails to cure such interference to PSE's reasonable satisfaction within such sixty (60) day period, or 13.3.2 the occurrence of any Event of Default. 13.4 Sprint Spectrum may terminate the Term upon thirty (30) days' prior written notice to PSE if Sprint Spectrum is unable (e.g., for technological reasons) to use the Site for the Permitted Activities or, due to significant opposition by any third party, it appears unlikely that zoning can be obtained for the Site in a timely fashion; provided, however, that Sprint Spectrum shall use reasonable efforts to obtain such zoning and/or resolve such opposition. 14. Default. 14.1 The occurrence of any one or more of the following events constitutes an "Event of Default" by Sprint Spectrum under this Permit: 14.1.1 Sprint Spectrum undertakes any activities on the Site other than the Permitted Activities; 141.2 Sprint Spectrum fails to pay when due the full amount of any fee or other payment under this Pen -nit, where such failure continues for fifteen (15) days after written notice thereof by PSE to Sprint Spectrum; 14.1.3 Sprint Spectrum fails to cure any other default under or breach of any provision of this Permit (i.e., other than a default or breach covered by Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 1 t paragraph 11.1.1) within thirty (30) days after PSE gives Sprint Spectrum written notice of such default or breach; except such thirty (30) day cure period will be extended as reasonably necessary to permit Sprint Spectrum to complete cure so long as Sprint Spectrum commences cure within the thirty (30) day cure period and thereafter continuously and diligently pursues and completes such cure; 14.1.4 two (2) or more defaults by Sprint Spectrum in the payment of any fee or other payments under the Permit which would allow PSE to issue a notice of default in any twelve (12) month period, which such occurrence will constitute a noncurable material default and breach of this Permit; 14.1.5 Sprint Spectrum deserts, abandons, or vacates any portion of a Site and fails to maintain any and all Equipment remaining at the Site. 14.2 If an Event of Default occurs, PSE (without notice or demand except as expressly required above) may, in addition to any other right or remedy to which PSE may be entitled under this Permit or applicable law, recover from Sprint Spectrum an amount equal to the sum of the following: 14.2.1 the actual costs of removing the Equipment and restoring the Site to its original condition; 14.2.2 the Annual Fees for the Site until such time as the Site is restored to its original condition, plus interest thereon from the date due until paid according to the terms of this Pen -nit; 14.2.3 the amount by which the Annual Fees and other benefits that PSE would have received under this Permit for the remainder of the Term after the date of termination exceeds the amount of the fair market rental value for the remainder of the Term that Sprint Spectrum proves could be reasonably avoided, discounted at the discount rate on the date of termination of the Federal Reserve Bank of the federal reserve district where the Site is located plus one percent=; and 14.2.4 all other sums of money and damages to which PSE may be entitled hereunder or under applicable law. 15. Effect of Termination. Within thirty (30) days after termination of the Term, Sprint Spectrum shall remove all Equipment from the Site and restore the Site to its original condition except for reasonable use, wear and tear. Sprint Spectrum will repair any damage to the Site caused during the removal of the Equipment. Following expiration of the above thirty (30) day period, PSE shall furnish to Sprint Spectrum a Iist of any removal, restoration, repair or other work that remains to be completed at the Site. Sprint Spectrum will thereafter complete the work specified on the list within ten (10) days after receipt of the list from PSE. If Sprint Spectrum shall fail to complete the specified work within the ten (10) day period, PSE may complete the work, or have the work completed through the most expeditious Sprint Spectrum SE63XC320 Marine View Substation— PSE (SEA123) Page 12 means available, at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 16. Release. Indemnity, Hold Harmless and Limitation of Liability. 16.1 Sprint Spectrum releases and shall defend, indemnify and hold hanmless the Indemnitees from any and all claims, losses, costs, liabilities, damages and expenses (including, but not limited to, reasonable attorneys' fees) arising (whether before or after termination of the Tenn) out of or in connection with the conduct of the Permitted Activities (including, without limitation, the Iocation of any Equipment at the Site, the performance of the Work, or the operation of the Equipment or the system of which the Equipment is a part), the enforcement of this Permit by PSE, any default under or breach of this Permit by Sprint Spectrum or the acts or omissions of Sprint Spectrum or any of its Support, the respective successors and assigns of Sprint Spectrum or any of its Support, the directors, officers, employees and agents of each of the foregoing, or anyone acting on Sprint Spectrum's behalf in connection with this Permit. To the fullest extent permitted by applicable law, the foregoing release, indemnity and hold harmless shall apply regardless of any act, omission, fault, negligence or strict liability of the Indemnitees; provided, however, that Sprint Spectrum shall not be required to so indemnify any Indemnitee(s) against any claim, loss, cost, liability, damage or expense to the extent the same is caused by or results from the negligence or willful misconduct of any Indemnitee(s). In connection with any action to enforce this paragraph 17.1, Sprint Spectrum waives any immunity, defense, or protection under any workers' compensation, industrial insurance or similar laws (including, but not limited to, the Washington Industrial Insurance Act, Title S 1, of the Revised Code of Washington). PSE is willing to permit the Equipment on the Site for the fees described in this Permit only in consideration of and in reliance upon such release, indemnity and hold harmless. Consequently, such release, indemnity and hold harmless shall be construed broadly in favor of the Indemnitees. 16.2 NOTWITHSTANDING ANY OTHER PROVISION OF THIS PERMIT, PSE SHALL NOT HAVE ANY LIABILITY TO SPRINT SPECTRUM FOR ANY: LOSS OF PROFIT OR REVENUE, LOSS OF USE OF THE EQUIPMENT OR THE SYSTEM, CLAIMS OF CUSTOMERS OF SPRINT SPECTRUM FOR SERVICE INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL, ECONOMIC OR CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR OTHERWISE, EVEN IF PSE HAS BEEN ADVISED OF THE POSSIBILITY OF THE SAME. 16.3 NOTWITHSTANDING ANY OTHER PROVISION OF THIS PERMIT, SPRINT SPECTRUM SHALL NOT HAVE ANY LIABILITY TO PSE FOR ANY LOSS OF PROFIT OR REVENUE, CLAIMS OF CUSTOMERS OF PSE FOR SERVICE INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA]23) Page 13 E EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR OTHERWISE, EVEN IF SPRINT SPECTRUM HAS BEEN ADVISED OF THE POSSIBILITY OF THE SAME. 16.4 PSE'S LIABILITY (WHETHER IN TORT, CONTRACT OR OTHERWISE AND NOTWITHSTANDING ANY FAULT, NEGLIGENCE (WHETHER ACTIVE, PASSIVE OR IMPUTED), PRODUCT LIABILITY OR STRICT LIABILITY OF PSE) UNDER THIS PERMIT OR WITH REGARD TO THE SITE SHALL IN NO EVENT EXCEED THE COMPENSATION ACTUALLY PAID TO PSE UNDER THIS PERMIT WITH RESPECT TO THE SITE. 17. Worker's Comoensaflop, Insurance and Bonds. 17.1 Sprint Spectrum shall ensure that Sprint Spectrum and all persons undertaking any Permitted Activities, including without limitation Sprint Spectrum's Support, maintain in effect at all times, coverage or insurance in accordance with the applicable laws relating to worker's compensation and employer's liability insurance (including, but not limited to, the Washington Industrial Insurance Act and the laws of the state in which any such person was hired), regardless of whether such coverage or insurance is mandatory or merely elective under the law. Sprint Spectrum shall furnish to PSE such assurance and evidence of such coverage or insurance (such as copies of insurance policies and Certificates of Compliance issued by the Washington State Department of Labor and Industries) as PSE may request. 17.2 Sprint Spectrum shall secure and maintain in effect at all tunes during the Term the following insurance: 17.2.1 fire insurance, with endorsements for extended coverage vandalism, and malicious mischief, on the Site, in an amount not Iess than ninety percent (90%) of the full replacement cost of the Site (including, without limitation, all equipment and facilities located thereon); and 17.2.2 Commercial General Liability Coverage, including personal injury, bodily injury, property damage, operations hazard, independent contractor coverage, contractual liability, products and completed operations liability and stop gap coverage, in limits not less than five million dollars ($5,000,000) for each occurrence (combined single limit) with Sprint Spectrum named as insured therein and PSE named as an additional insured therein as their respective interests may appear. 17.3 All required insurance policies must be. taken out with reputable national insurers that are licensed to do business in the jurisdiction where the Site is located. Sprint Spectrum will deliver to PSE a Certificate of Insurance in the form attached to this Permit as Appendix 5 prior to commencernent of performance of any of the Work. All Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 14 policies must contain an undertaking by the insurers to notify PSE in writing not less than fifteen (15) days before any material change, reduction in coverage, cancellation or termination of the insurance. Sprint Spectrum and PSE will each year review the limits for the insurance policies required by this Permit. Policy limits will be adjusted to proper and reasonable limits as circumstances warrant, but policy Iimits will not be reduced below those stated in paragraph 17.2 and no increases in the policy limits will be effective unless Sprint Spectrum and PSE mutually agree. 17.4 Sprint Spectrum shall also furnish PSE with such additional assurance and evidence of such insurance (such as copies of all insurance policies) as PSE may from time to time request. Within thirty (30) days after any notice of termination, cancellation, expiration or alteration in any policy of insurance required under this Pennit, Sprint Spectrum shall deliver to PSE a Certificate of Insurance acceptable to PSE with respect to any replacement policy. 17.5 Sprint Spectrum shall ensure that any policies of insurance that Sprint Spectrum or any of its Support carry as insurance against property damage or against liability for personal injury (including death) or property damage shall include a provision therein providing a waiver of the insurer's right to subrogation against the Indemnitees. To the extent permitted by its insurance policies, Sprint Spectrum hereby waive all rights of subrogation against the Indemnities. 17.6 All insurance carried by Sprint Spectrum or any of its Support shall be primary insurance with respect to the interests of PSE, and any insurance or self-insurance maintained by PSE is in excess and not contributory insurance with the insurance required hereunder. 17.7 The requirements of this Permit as to insurance and acceptability to PSE of insurers and insurance to be maintained by Sprint Spectrum are not intended to and shall not in any manner limit or qualify the liabilities and obligations of or assumed by Sprint Spectrum under this Permit. 18. Assignment. Successors and Assigns. 18.1 Sprint Spectrum shall not assign this Permit or any portion of its rights in this Permit, except as follows: 18.1.1 to any person or entity that controls, is controlled by or under common control with Sprint Spectrum (the "Acquiring Affiliate"); provided that Sprint Spectrum gives PSE written notice of any such assignment or transfer and pays all amounts then outstanding and owing to PSE under this Permit; provided further that the Acquiring Affiliate certifies to PSE in writing (and provides such documents as may be requested by PSE to establish) that the Acquiring Affiliate (i) will assume all of the obligations of Sprint Spectrum under this Permit, and (ii) and will comply with all of the provisions of this Permit; and provided further that Sprint Spectrum Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 15 furnishes to PSE such information regarding the Equipment affected by such assignment or transfer as may reasonably be requested by PSE; 18.1.2 to Sprint Spectrum's lender(s) for security purposes in connection with the financing and refinancing, from time to time, by Sprint Spectrum, provided that upon any transfer pursuant to any foreclosure of such security or any sale or other transfer in lieu of such foreclosure the person or entity acquiring the interests subject to such transfer assumes all of the obligations of Sprint Spectrum under this Pen -nit; or 18.2 Except as specifically provided in paragraph 18.1, any assignment or apportionment, or purported assignment or apportionment of this Permit, whether it be express, by operation of law or otherwise, shall be voidable by PSE. In any event, no assignment or apportionment of this Permit shall relieve Sprint Spectrum from any of its liabilities or obligations under this Permit. If at any time the aggregate net worth of Sprint Spectrum and any Acquiring Affiliates bound by this Permit is less than or Sprint Spectrum fails to furnish PSE evidence of such aggregate net worth as PSE may reasonably request, then PSE will be entitled to immediately terminate the Term upon written notice of such tennination to Sprint Spectrum. Subject to the foregoing restrictions on assignments without the prior written consent of PSE, this Permit shall be fully binding upon, inure to the benefit of and be enforceable by the successors and assigns of the respective Parties hereto. 19. Casualty or Condemnation of the Site 19.1 If there is a casualty to any structure upon which the Equipment is located, PSE will use reasonable efforts to repair or restore the structure within sixty (60) days. Upon completion of such repair or restoration, Sprint Spectrum will be entitled to reinstall the Equipment. In the event such repairs or restoration will, in PSE's reasonable estimation, require more than sixty (60) days to complete: 19.1.1 Sprint Spectrum or PSE will be entitled to terminate the Tenn; or 19.1.2 unless the Term is terminated as provided in paragraph 19.1.1, Sprint Spectrum may immediately install temporary Equipment, including any necessary supporting structure, (a) at the Site, or (b) at another unused portion of PSE's property adjacent to the Site, to the extent Sprint Spectrum has the rights to do so, while PSE makes repairs to the Site and so long as the temporary Equipment and associated Work does not interfere with PSE's own restoration and operation of its facilities. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA] 23) Page 16 19.2 If there is a condemnation of the Site, including without limitation a transfer of the Site by consensual deed in lieu of condemnation, then the Term will terminate upon transfer of title to the condemning authority, without further liability to either Party under this Permit. Sprint Spectrum may pursue a separate condemnation award for the Equipment and any relocation or other casts from the condemning authority provided that such award does not reduce the amount of PSE's award. 20. Subordination. 20.1 Sprint Spectrum agrees that this Permit is subject and subordinate at all tunes to the lien of all mortgages and deeds of trust securing any amount or amounts whatsoever which may now exist or hereafter be placed on or against the Site or on or against PSE's interest or estate therein, and any underlying ground lease or master lease on a particular Site, all without the necessity of having further instruments executed by Sprint Spectrum to effect such subordination. 20.2 This Permit is further subject to any and all restrictions or other terms or conditions contained in the underlying ground lease, master lease, easement, license, franchise, permit or other instrument of authorization or conveyance (an "Instrument") with respect to the Site. Sprint Spectrum agrees to commit no act or Omission which would constitute a violation of the terms and conditions of any Instrument for the Site insofar as PSE has provided a copy of such Instrument to Sprint Spectrum or otherwise notified Sprint Spectrum of the term or condition in question. 20.3 PSE shall not be required to obtain any consent required under any Instrument from the landlord or other party to such Instrument for purposes of this Permit, unless hereafter agreed upon by PSE in writing. 20.4 If a restriction contained in an Instrument for the Site prevents Sprint Spectrum from installing, maintaining or operating the Equipment or accessing the Site, Sprint Spectrum will be entitled to tenninate the Term. 20.5 Upon the termination or expiration of any Instrument with respect to the Site, the Term shall automatically terminate without Iiability to either Party. Sprint Spectrum acknowledges that many of PSE's underlying Instruments grant to the property owner the right to terminate such Instruments, and that in the event of such termination, the Term shall terminate concurrently therewith without liability to either Party. 20.6 Upon any sale or other transfer of all or any portion of the Site, the Term will automatically terminate except to the extent the purchaser or transferee and Sprint Spectrum enter into an agreement for Sprint Spectrum's continued use of the Site and release PSE from any further obligation or liability with respect to the Site. PSE shall have no obligation to request or obtain such agreement from the purchaser or transferee. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 17 20.7 PSE will not materially breach the terms or conditions of any Instrument with respect to a particular Site in a manner that causes Sprint Spectrum to lose its use of the Site. 21. Notices. Any notice, request, approval, consent, instruction, direction or other communication given by either PSE or Sprint Spectrum to the other under this Pen -nit shall be in writing and shall be delivered in person or mailed, properly addressed and stamped with the required postage, to: If to PSE: Puget Sound Energy, Inc. P.O. Box 90868 GEN-02E Bellevue, WA 98009-0868 Attn: Communications Siting and Services Department If to Sprint Spectrum: Sprint National Lease Management Sprint Law Department 6391 Sprint Parkway 6391 Sprint Parkway Mailstop KSOPHT0101-Z2650 Mailstop KSOPHT0101-Z2650 Overland Park, KS 66251-2650 Overland Park, KS 66251-2650 Attn: Real Estate Attorney Either Party may from time to time change such address by giving the other Party notice of such change in accordance with the provisions of this paragraph 21. 22. No Partnership. This Permit shall not be interpreted or construed to create an association, joint venture or partnership between the Parties or to impose any partnership obligations or liability upon either Party. Neither Party shall have any right, power or authority to enter into any agreement or undertaking for or on behalf of, to act as or be an agent or representative of, or to otherwise bind the other Party. 23. Attornevs' Fees. The prevailing Party in any suit, action, or arbitration filed or held concerning this Permit shall be entitled to recover, in addition to all other relief, its reasonable attorney's fees incurred in connection therewith, both at trial and on any appeal. 24. Severability. The invalidity or unenforceability of any provision of this Permit shall not affect the other provisions hereof, and this Permit shall be construed in all respects as if such invalid or unenforceable provisions were omitted. 25. Survival. All provisions of this Permit which may reasonably be interpreted or construed as surviving the completion, termination or cancellation of the Term or this Pennit, shall survive the completion, tennination or cancellation of the Term or this Pen -nit. 26. Headings. The headings of sections and paragraphs of this Permit are for convenience of reference only and are not intended to restrict, affect or be of any weight in the interpretation or construction of the provisions of such sections or paragraphs. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 18 27. Nonwaiver. The failure of either Party to insist upon or enforce strict performance by the other Party of any of the provisions of this Permit, or to exercise any rights under this Permit, shall not be construed as a waiver or relinquishment to any extent of its right to assert or rely upon any such provisions or rights in that or any other instance; rather, the same shall be and remain in full force and effect. 28. Force Maieure. If a Party is delayed or hindered in, or prevented from performance required under this Permit (other than any delay or failure relating to payment of money, including, without limitation, the Annual Fees and all reimbursable costs and expenses described elsewhere in this Permit) by reason of earthquake, landslide, strike, lockout, labor trouble, failure of power, riot, insurrection, war, acts of God or other reason of like nature not the fault of the such Party, such Party is excused from such performance for the period of delay. The period for the performance of any such act shall then be extended for the period of such delay. 29. Memorandum of Use. Neither Party shall record this Pen -nit or otherwise cause this Permit to be recorded. However, upon the request of either Party, the Parties shall execute, acknowledge, deliver and record a memorandum of use in form and content substantially the same as the attached Appendix 6. Upon termination of the Tenn for any reason, the Parties shall execute, acknowledge, deliver and record a termination document in form and content acceptable to PSE. 30. Entire Agreement. The rights and obligations of the Parties hereunder shall be subject to and governed by this Permit. This Permit sets forth the entire agreement of the Parties, and supersedes any and all prior agreements, with respect to the Equipment, the Work, the Site and other subject matter of this Permit. This Permit may not be modified except by a writing executed contemporaneously herewith or subsequent hereto signed by both Parties. 31. Applicable Law. This Permit shall in all respects be interpreted, construed and enforced in accordance with the laws of the State of Washington. 32. Conditional Approval. 32.1 Sprint Spectrum shall provide complete detailed final jurisdictionally approved construction drawings before construction begins for PSE's review and approval. Said drawings shall show in detail the following, if applicable: 32.1.1 Grounding design of equipment and fencing in accordance with the National Electrical Safety Code provisions in Section 9, and PSE's internal design policies. Location of the telephone cable installation { from source to the equipment cabinets. 32.1.2 Field verification of location of property lines establishing that proposed equipment shelter and pole location lies as noted, Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 19 1 32.1.3 Landscape design showing acceptable vegetation compatible with electrical facilities and or substations. 32.2 Any comments and conditions noted during PSE's review process. 32.3 This is an existing Qwest Wireless site 4SEA123. Sprint Spectrum's installation at the site will consist of utilizing a portion of Qwest Wireless's existing antennas and coax on the monopole located on the Substation property. Sprint Spectrum's BTS cabinets will also be located in the existing cabinet area. 32.4 A list of materials and equipment provided to PSE in advance of construction for PSE's review. Upon arrival, materials will be delivered to the site of a mutually acceptable location and accepted by PSE before construction commences. 32.5 No construction shall commence prior to the receipt and written approval by PSE of the final construction drawings and evidence of authorization by all governmental agencies having jurisdiction over the project. An on site pre -construction meeting shall be scheduled prior to construction and as -built drawings shall be provided after completion of construction. 32.6 If any landscaping is part of the wireless facilities at this site it must be approved by PSE, and it will be Sprint Spectrum's responsibility to maintain the installed landscaping and meet the terms and conditions of the landscape plan. If the installed landscaping is not maintained to jurisdictional and/or PSE standards, then PSE may, at its option but not an obligation, perform these maintenance activities at Sprint Spectrum's cost and expense. Sprint Spectrum agrees to reimburse PSE for these costs within thirty (30) days from the date of the statement. 32.7 Sprint Spectrum will provide wireless facility specifications and design, and will procure and install their wireless system with all costs being paid by Sprint Spectrum as provided for herein. PSE will determine the area available, if any, for Sprint's use. In the event PSE decides that the space required by Sprint can not be provided, PSE may withhold site approval. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 20 ' o i { i i Sprint: Sprint Spectrum L.P. Z By. (;� SP94T spEcTPiuM L.F. PETER MUNSER Its: SITE DEVELOPMENT MANAaF-R (Title) Date Signed:_ j STATE OF _ a11r C } SS COUNTY OF PSE: Puget Sound Energy, Inc. By: Howard Strong Its: Manager Real Estate Date Signed: r--?N�yL -- On this � day of _ — _ _ 2004, before me, a Notary Public in and for the State of C:-K---" duf commissioned and sworn, persly appeared 1�' �.V o me known to be the OTT Vek./� " Sprint Spectrum that cuted the foregoing instrument and acknowledged the same to be the free and voluntary act and deed of said municipal corporation, for the uses and purposes therein mentioned, and on oath stated that he is authorized to execute the said instrument. Witness my hand and official seal hereto affixed tye clay and year in this certificate above written. r w , t/ USA D. fS my Print Nam L L Commission # 1303787 Notary Pub is in and 1or the State of -� Nofory, Public - Calitntnla Residing at Fu°m4 county My commission expires {� My Comm. Expires May 7, 2005 I Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 21 JUN 10 2014 CITY OF FEDERAL WAY e 08/07/2008 i w • ?'u44 1 dell Jove S I Nh A" S 1� ar Padit HWY $ mi" P � PadMfc I-Irrr a 2 r l r P �• ss��y qy 1R' r J I 10 jl r' U I Y OF FEDERAL WAY CDS At all new services & grounding trenches, provide "WARNING" tape at 12" below grade, DIG ALERT "CALL BEFORE YOU DIG" 1-800-424-5555 UTILITY NOTIFICATION CENTER OF WASHINGTON W S p rintV% WASHINGT N STATE CODE QO PLIANCEc ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES, NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. • 2012 IBC, STANDARDS AND AMENDMENTS—WAC 51-50; • 2012 IMC, STANDARDS AND AMENDMENTS—WAC 51-52; 2012 IFC, STAH[70M AND AMENDMENTS—WAC 51-54; • 2012 IPC, STANDARDS AND AMENDMENTS—WAC 51-56; 51-57 ACCESSIBILITY FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2009 IBC BUILDING CODE, I CODE BLOCK j SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY • INSTALL 131 3NEW JWTENWI5 (1 PER SECTDR) • INSTALL RRH UNITS (1 M SECTOR) INSTALL 6 JUNCTION CYLINDERS (2 PER SECTOR) • INSTALL 3 FILTERS PROJECT DESCRIPTION APPROVAL SIGNATURE DATE BITE ACQUISITION MANAGER CONSTRUCTION MANAGER A&E MANAGER PLANNING CONSULTANT RF MANAGER RF ENGINEER PROPERTY OWNER SPRINT REPRESENTATIVE AAV MANAGER SIGNATLIRE BLOCK THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY _ UlPMENT UPGRADE 2.5 LAUNCH JEFFRIES SE63XC320 / CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY LATITUDE: 47.339364 / 42° 20' 21 .71 " (NAD 83) (PER GOOGLE EARTH) LONGITUDE:—122.311825 / 122° 18' 42.57" (NAD 83) (PER GOOGLE EARTH) MONOPOLE SEATTLE MARKET a ^1tt' • C y 3 f � � Game E 9 • .c � � colas svwa :""��� g aa.ws q I - - 6 F '"SITE` —s••..a 0• sar.a ; � 8 can � �, S u �•' 'ie, f�L AREA MAP 9 z L � Izj 5 LTE r°+s m ® •M1.- 7 i VICINITY MAP FROM GENERAL DYNAMICS IN BELLEVUE, WA HEAD SOUTH ON 124TH AVE NE TOWARDS NE 10TH PL 0.1 l,11 TAKE SECOND RIGHT ONTO NE 8TH ST 0.7 NI MERGE ONTO 1-405 SOUTH TOWARDS RENTON 13.9 MI 1-405 S BECOMES WA-518 W 0.1 Mi MERGE ONTO 1-5 S TOWARDS PORTLAND 7.6 MI TAKE EXIT 147 FOR S 272ND ST 0.3 N TURN RIGHTT ONTO S 272ND ST 0.2 MI TURN LEFT ONTO PACIFIC COAST HWY S/WA-99 1.0 M1 TURN LEFT ONTO S 288TH ST 0.8 MI TAKE THE FIRST RIGHT ONTO 18TH AVE S 0.2 MI DESTINATION WILL BE ON THE LEFT 29208 18TH AVE S, FEDERAL WAY, WA 98003, USA 24.67 MI I DRIVING DIRECTIONS I SHEET DESCRIPTION T-1 TITLE SHEET N-1 GENERAL NOTES A-1 PARCEL PLAN A-2 ENLARGED SITE PLAN A-3 EQUIPMENT PLAN A-4 ANTENNA PLANS & SCHEDULE A-5 EXISTING & PROPOSED EAST ELEVATION A-6 EXISTING & PROPOSED NORTH ELEVATION A-7 EQUIPMENT DETAILS RF-1 ANTENNA AND CABLE COLOR CODING DETAILS E-1 SCHEMATIC GROUNDING PLAN E-2 GROUNDING DETAILS E-3 GROUNDING DETAILS SHEET INDEX APPLICANT: SPRINT SPECTRUM LLC 1000 124TH AVE NE. SUITE 210 BELLEVUE, WA 98005 CONTACT: KEVIN FOY PH: (206) 427-5856 EMAIL: KEVIN.FOYOSPRINT.COM PROPERTY IN7 4R�4ATIOhI PROPERTY OWNER: PUGET SOUND ENERGY ADDRESS: PO BOX 91269 BOT-01H BELLEVUE. WA 98009 TOWER OWNER: CROWN CASTLE USA SITE ID: 880427 ZONING CLASSIFICATION: BC COMMUNITY BUSSINESS CONSTRUCTION TYPE: IIB OCCUPANCY: U JURISDICTION: CITY OF FEDERAL WAY CURRENT USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY PARCEL NUMSER(S]: 304020-0065 LEASE AREA: 810 SQ. FT. PROJECT SUMMARY ARCHITECT: THOMAS R HOLLAND, AIA PACIFIC TELECOM SERVICES, LLC 506 2ND AVE, SUITE 210 SEATTLE. WA 96104 CONTACT: AMANDA MARTIN PH: (206) 342-6396 EMAIL: AMARTIN®PTSWA.COM STR U CTU RAL LNG1 N EER: B+T GROUP 1717 S BOULDER, SUITE 300 TULSA. OK 74119 CONTACT: VENU AMBATI PH: (918) 587-4630 EMAIL- BTWO®BTGRP.COM PROJECT MANAGER: CROWN CASTLE USA 8432 154TH AVE NE, BLDG C REDMOND, WA 98052 CONTACT: TOM GOODE PH: (425) 202-0191 EMAIL: TOM.GOODE®CROWNCASTLE.COM CONSTRUCTION MANAGER, EN CASTLE USA 'APPROVAL 8432 154TH AVE N< REDMOND.MWA 98952 CONTRC*: LEf RASSEfT �N1 PH: (206) 852-0443 ZONING & PERMITTING: of d CROWN CASTLE USA. 8432 REDMOND.AVE H 4 CONTACT.- D, WA 9805 CONTACT: KEVIN CF4WC rr 'f 11 PH: (425) 202-27 EMAIL: KENN.CHNiC PUGEf SOUND EH L[f�^^�� CONTACT: TIM GASSE w �+L■ r G.v PH: 206-947-0335 TELCO COMPANY: CENTURYLINK 8502 SOUTH STEELE ST TACOMA, WA 98409 PMEAfED RE ENGINEER: TBD JUN 10 2014 CITY OF FEDERAL WAY CDS PROJECT TEAM 1 Sprint>* AS 0 CcOLE r •.c,na rccceer ccan�F.. L e 111 S JACKSON ST, 2N0 FLOOR SEATTLE. WA 98104 PROJECT INFO A&NTION: JEFFRIES SEC 3XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE 02-25-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION IN[I1A1.S A 11/29/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET 6CENSURE 4072 REGISTERED ARC IT T THOMAS R. HOLLAND STATE OF WASH INGTON REN.02-18-16 _ l "-so �) SHEET TITLE TITLE SHEET SHEETNUMBER: T-1 REVISION: 0 SE63XC32 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE, ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY GENERAL NOTES: ) 1. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND NETWORK CARRIER OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES AS THEY MAY BE DISCOVERED IN PLANS, DOCUMENTS, NOTES, OR SPECIFICATIONS, PRIOR TO STARTING CONSTRUCTION INCLUDING, BUT NOT LIMITED BY, DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR, OMISSION, OR INCONSWENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN 9ROUBNT TO THE ATTENTION OF ARCHITECT AND NETWORK CARRIER CONSTRUCTION PROJECT MANAGER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY ARCHITECT AND NETWORK CARRIER CONSTRUCTION PROJECT MANAGER. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND THE CONTRACTOR HAVING BEEN AWARDED THIS PROJECT SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 3. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE NETWORK CARRIER PROJECT SCOPE AND THE INTENT OF THESE DOCUMENTS, THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 4. 11X17 COPIES OF DRAWINGS ARE NOT TO BE SCALED DUE TO DISTORTIONS RESULTING FROM MULTIPLE REPROGRAPHIC COPIES, WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALES SHOWN ON PLANS. 5- OWNER, CONTRACTOR, AND NETWORK CARRIER REPRESENTATIVE SHALL REVIEW AND CONFIRM THAT PROJECT SCOPE, DESIGN INTENT AND UTILITY COORDINATION ITEMS ARE INCLUDED IN THE DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. 6 THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION FROM NETWORK CARRIER REPRESENTATIVE TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 7.. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS OR TENANTS. 8. THE CONTRACTOR SHALL PROVIDE NETWORK CARRIER PROPER INSURANCE CERTIFICATES NAMING NETWORK CARRIER AS ADDITIONAL INSURED, AND PROVIDE NETWORK CARRIER PROOF OF LICENSE(S) INCLUDING PE & PD INSURANCE, 9. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT- 10, THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE 11. ALL WORK PERFORMED ON THE PROJECT ALONG WITH ALL MATERIALS INSTALLED, SHALL COMPLY IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL LIKEWISE ISSUE NOTICE TO ALL SUB -CONTRACTORS THAT THEY SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPALITY, UTILITY COMPANY AND LOCAL/STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK, 12. A COPY OF THE GOVERNING AGENCY ISSUED AND APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW, SHALL BE AVAILABLE AT THE JOB SITE FOR INSPECTION AT ALL TIMES. THE ORIGINAL PERMIT SET PLANS ARE NOT TO BE USED BY THE WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION, COMPLETE WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES UNDER THE DIRECT CARE OF THE SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY THE NETWORK CARRIER CONSTRUCTION PROJECT MANAGER WITH A COPY OF ALL REVISIONS, ADDENDA, AND/OR CHANGE ORDERS AT THE CONCLUSION OF THE WORK AS A PART OF THE AS -BUILT DRAWING RECORDS- 13. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE, 14. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS, NOTES, DIMENSIONS, AND ALL REQUIREMENTS PRIOR TO THE START OF ANY WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE JOB SITE WHILE WORK IS IN PROGRESS UNTIL THE JOB IS COMPLETE 16. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING UTILITIES SHOWN OR NOT SHOWN ON THE PLANS, ALONG WITH PROTECTING THEM FROM DAMAGE. THE CONTRACTOR AND SUBCONTRACTOR SHALL BEAR THE EXPENSES OF REPAIR AND/OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGE RESULTING FROM OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. 17. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS: A PROPERTY NOTED TO BE RETURNED TO THE OWNER. B. PROPERTY NOTED TO BE REMOVED BY THE OWNER. 18- THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS SHALL PROVIDE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES, MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT, TRADE STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION. 19, WHEN ROOF TOP OR TOP FLOOR DECK TEMPORARY STAGING IS REQUIRED, MATERIALS SHALL BE EVENLY DISTRIBUTED OVER ROUGH FRAMED FLOORS OR ROOFS SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE, TEMPORARY SHORING AND/OR BRACING IS TO BE PROVIDED WHERE THE STRUCTURE DOESN'T HAVE THE DESIGN STRENGTH FOR ADDITIONAL LOADING, 20- SEAL ALL PENETRATIONS WITHIN FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THE SUBJECT FACILITY AND OR PROJECT SITE. T INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE 21. BUILDING / NOTIFIED PRIOR TO ANY GROUND DISTURBANCE, CONSTRUCTION, AND ANY OTHER PROJECT EFFORT AS MANDATED BY THE GOVERNING AGENCY. 22. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-AIOBC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION, 23. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ADJACENT TO THE PROPERTY. 24. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION DISPOSING OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE, 25. NEW CONSTRUCTION INSTALLED ADJACENT EXISTING BUILDINGS OR CONSTRUCTION SHALL ARCHITECTURALLY MATCH THE EXISTING IN TERMS OF COLOR, TEXTURE, FINISH MATERIALS, ETC., EXCEPT AS NOTED IN THE PLANS AND SPECIFICATIONS. 26. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING, AND/OR OTHER ANCHORAGE DEVICES REQUIRED FOR THE INSTALLATION OF FIXTURES, MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS TO INSURE A PROPER AND CODE COMPLIANT INSTALLATION. 27. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING INSTALLATIONS THAT ARE CONSTRUCTED LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE BASED ON THE CONSTRUCTION DRAWINGS. THE CONTRACTOR SHALL COMPARE EXISTING CONDITIONS WITH THE PROPOSED DESIGN PRIOR TO CONSTRUCTION AND REPORT ANY DISCREPANCIES OR INCONSISTENCIES TO THE NETWORK CARRIER'S REPRESENTATIVE AND FURTHER TO THE A&E SUCH THAT THE NEW INSTALLATION WILL LIKEWISE BE LEVEL, ERECT, EVENLY ALIGNED, PLUMB AND TRUE. ARCHITECT AND NETWORK CARRIER SHALL BE NOTIFIED OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES PRIOR TO ANY CONSTRUCTION. 28. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE GOVERNING AGENCIES. 29. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY RESPONSIBLE FOR RECORDING THE RESULTS. 30. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS AND SHALL NOT STORE OR STAGE MATERIALS ON PUBLIC PROPERTY WITHOUT A PERMIT TO DO SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE 31. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN ALL CONDITIONS UNLESS ILLUSTRATED AND NOTED OTHERWISE. 32. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN CUTTING, FITTING, PATCHING, ETC., SO AS TO BE PREPARED PROPERLY BY THE WORK OF OTHER TRADES. 33. ALL DEBRIS AND REFUSE SHALL BE REMOVED FROM THE PROJECT PREMISES AND LEFT IN A CLEAN SWEPT CONDITION AT ALL TIMES BY EACH TRADE AS THEY PERFORM THEIR OWN PORTION OF THE WORK. 34. NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES, AND/OR ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER GUARANTEE OR WARRANTY THAT MAY BE IN EFFECT IS DONE THROUGH THE COMPANY OR MANUFACTURER PROVIDING THE PRODUCT, FIXTURE, AND/OR EQUIPMENT UNLESS SPECIFIC RESPONSIBILITY IS ALSO PROVIDED BY THE CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM, 35. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 36. WHEN APPLICABLE, CONTRACTOR IS RESPONSIBLE TO CALL, COORDINATE AND MAKE ARRANGEMENTS FOR R.O.W. AND/OR PRIVATE PROPERTY LOCATES BASED ON SPECIFIC SITE REQUIREMENTS. 37_ SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION AS APPLICABLE. 38. CONTRACTORS TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO NETWORK CARRIER'S REPRESENTATIVE ALONG WITH REDLINED CONSTRUCTION SET. 39. CONTRACTOR SHALL DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED ALONG WITH PHOTOGRAPHS PER NETWORK CARRIER REQUIREMENTS. 40. CONTRACTOR SHALL COORDINATE AND SEEK APPROVAL OF ALL POWER DRAW, INSTALLATION AND/OR MODIFICATIONS WITH POWER COMPANY, OWNER AND JURISDICTION AS REQUIRED. CONTRACTOR SHALL REPORT POWER INSTALLATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 41. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY NETWORK CARRIER CONSTRUCTION MANAGER 42. THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPLETE ACCEPTING UNDER THIS CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR EXCEPTION: THE ROOFING SUBCONTRACTOR SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. ANTENNA & COAX NC.. _S 43. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE 1. CONSTRUCTION OF THE PROJECT. 44. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS 2. AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT, BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS REPRESENTATIVE CONTRACTOR SHALL OBTAIN PERMIT (UNLESS OTHER ARRANGEMENTS HAVE BEEN MADE) AND MAKE FINAL PAYMENT FOR SAID DOCUMENT(S). 3. 45- NETWORK CARRIERS REPRESENTATIV E SHALL REVIEW AND APPROVE SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT. NETWORK CARRIER'S REPRESENTATIVE PROJECT APPROVAL OF A SEPARATE OF A U APPROVAL N ASSEMBLY IN WHICH THE ITEM ITEM SHALL NOT INCLUDE AP RO FUNCTIONS. VERIFY EACH COAXIAL CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE. THE MAXIMUM COAXIAL CABLE LENGTH AND CORRESPONDING COAXIAL CABLE DIAMETER HAS BEEN ESTIMATED. THIS CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR CONSTRUCTION. ACTUAL ANTENNA CABLE LENGTH($) MAY VARY FROM ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. COAXIAL GABLE SHALL BE PROVIDED BY NETWORK CARRIER REPRESENTATIVE ALL MAIN CABLES SHALL UTILIZE GROUND KITS, GROUNDED AS FOLLOWS: A NEAR ANTENNA RAD CENTER ELEVATION, B. MIDDLE OF TOWER (MID -HEIGHT OF ANTENNA). IF CABLE RUN IS OVER 200'. C. BOTTOM OF TOWER, D. AT MASTER GROUND BAR 3'-0" FROM MMBS-BBU CABINET. 4. ALL TOP JUMPERS SHALL BE LENGTHS AS SHOWN AND INSTALLED RY CONTRACTOR. 46. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY NETWORK CARRIER 5. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS 47. CONTRACTOR SHALL PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS. SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY EQUIPMENT UTILIZED DURING CONSTRUCTION. 6. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON RF SHEET(S) AND AS FOLLOWS: 48. CONTRACTOR SHALL PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE A. MAIN LINE COLOR BANDS SHALL BE 2" WIDE MAINTAIN 1" SPACING BETWEEN COLORS CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND B. FREQUENCY COLOR BANDS SHALL BE 2" WIDE WITH NO SPACE BETWEEN COLORS, MAINTAIN EXISTING SURFACE DRAINAGE SLOPES C. JUMPER COLOR BANDS SHALL BE 1" WIDE. WITH 1" SPACE- 49. CONTRACTOR SHALL REPLACE EXISTING LANDSCAPE VEGETATION DAMAGED DUE D. START COLOR BANDS 2" BEYOND WEATHERPROOFING. TO CONSTRUCTION ACTIVITIES, AND REPAIR, RESTORE AND MODIFY EXISTING E. START SELECTOR COLOR NEXT TO END CONNECTORS. IRRIGATION LINES IF NECESSARY TO OPERATING CONDITION, PROVIDING FULL COVERAGE TO IMPACTED AREAS. 7. FINAL COAXIAL ANTENNA CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF ENGINEER. SEE ANTENNA SCHEDULE 50. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, 8, SEE CONSTRUCTION MANAGER FOR ANTENNA SUPPORT ASSEMBLY TYPE. CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER TO OBTAIN CONTACT INFORMATION AND UTILIZE THE EXISTING ROOFING CONTRACTOR OF RECORD 9. ALL COAXIAL CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, NOT TO EXCEED 3' OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH AND HAVING THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL EXISTING WARRANTY ENSURING 100% MOISTURE PROTECTION. REPORT. 51. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, CONTRACTOR 10. PROVIDE AT LEAST 6" OF SLACK IN THE MAIN COAXIAL CABLES AT THE ANTENNA MOUNTING SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT ELEVATION TO PROVIDE FOR FUTURE CONNECTOR REPLACEMENT. THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) EXISTING EXTERIOR G FACADE CTOR RES. AND COLORS. EOR FLATHEAD �L1 q� Vpp COAX & HYBRID COAX NOTE SHALL FURTHERMORETENISURETTIXHE)U E OF COUNTERSUNK ANTENNA FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION T. VERIFY EACH HYBRID CABLE LENGTH, DIAMETER, ROUTING, COLOR CODING AND ALL REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS APPURTENANCES WITH NETWORK CARRIER REPRESENTATIVE. SHALL BE PROVIDED TO THE CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION, _ ETER HAS BEEN ESTIMATED THIS 52. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE ANCHORING TO AN EXISTING CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT 3. DRAWING SET" HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE 4, PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 53. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING 5. TIES FOR ALL CABLING TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIESHALL NOT SHNOT BE PERMITTED FOR USE ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE & SHALL BE PANDUD CW. METAL LOCKING TIES MODEL HO. MLT4S-CP UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC. 54- CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID AND CONSTRUCTION PROJECT- 7. 55. CONTRACTOR SHALL OBTAIN, REVIEW AND EXECUTE ALL NETWORK CARRIER CONSTRUCTION STANDARDS (MOST RECENT REVISION) AS A PART OF THIS BID AND CONSTRUCTION PROJECT. 8. 56. CONTRACTOR SHALL BE RESPONSIBLE TO SET ELECTRONIC TILTS FOR NEWLY INSTALLED ANTENNAS UNDER THE CONDITION THAT THE CONTRACTOR OBTAIN THE MOST RECENT COPY OF THE RF TILT INFORMATION SUCH THAT THE ACCURATE CONTROLLER CAN BE ORDERED AND INSTALLED. 57. A STRUCTURAL ANALYSIS SHALL BE COMPLETED AND SUBMITTED TO THE NETWORK CARRIER REPRESENTATIVE AND CONTRACTOR DEMONSTRATING CAPACITY AT THE EXACT LOCATION OF EXISTING CONDITIONS TO SUSTAIN ADDITIONAL HEAVY BATTERY CABINETS OR OTHER OUT OF SCOPE EQUIPMENT- 5& THE CONTRACTOR SHALL PROVIDE MATERIALS LIST (BOM) TO THE NETWORK CARRIER REPRESENTATIVE PRIOR TO CONSTRUCTION. THE HYBRID CABLE LENGTH AND CORRESPONDING DIAM CABLE LENGTH IS APPROXIMATE, AND IS NOT TO BE USED FOR FABRICATION OR CONSTRUCTION- ACTUAL ANTENNA CABLE LENGN(S) MAY VARY FROM ESTIMATED MAXIMUM LENGTH AND MUST BE VERIFIED. EXCESS CABLE LENGTHS TO BE DRESSED IN A MANNER APPROVED SY NETWORK CARRIER REPRESENTATIVE- CABLES CANNOT BE CUT TO FIT. HYBRID CABLE INTERNAL GROUND WIRE TO BE GROUNDED AT TOP AND BOTTOM PER NETWORK CARRIER SPECIFICATIONS. EXCESS TOP 15' HYBRID CABLE FIBER JUMPERS TO BE DRESSED IN A MANNER APPROVED BY NETWORK CARRIER REPRESENTATIVE, CANNOT BE COILED, MUST BE SECURED TO TOWER MOUNTS. ALL MAIN CABLES SHALL BE COLOR CODED PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON RF SHEET(S) AND IN ACCORDANCE WITH NETWORK CARRIER SPECIFICATIONS. BANDING SHALL BE IN ACCORDANCE PER THE CABLE COLOR CODING DIAGRAMS AS SHOWN ON OF SHEET(S) AND AS FOLLOWS: A. MAIN LINE COLOR BANDS SHALL BE 2" WIDE. MAINTAIN 1" SPACING BETWEEN COLORS. B. JUMPER COLOR BANDS SHALL BE 1" WIDE WITH 1" SPACE. C. START COLOR BANDS 2" BEYOND WEATHERPROOFING. FINAL HYBRID CABLE SIZES SHALL BE DETERMINED BY NETWORK CARRIER RF ENGINEER. SEE CABLE SCHEDULE, BASED UPON FINAL RUN LENGTHS DETERMINED BY NETWORK CARRIER REPRESENTATIVE. - ALL HYBRID CABLE WILL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE AT DISTANCES NOT TO EXCEED 3' HORIZONTALLY OR 4' VERTICALLY OR THE CABLE MANUFACTURES SPECIFICATIONS WHICHEVER IS LESS, WITH HARDWARE SPECIFIED IN THE COAXIAL CABLE ROUTING DETAILS OF THE SUPPLIED STRUCTURAL REPORT. t. Spri ntP ■ l S'Y MCCO� r ram PACIFIC TELECOM SERVICES, L C III S JACKSON ST. 2ND FLOOR SEATTLE, WA 99104 PROJECT INFORMATION: JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE- 0 2- 2 5- 1 4 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION IINRIAL5 A )1/29/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET L I C ENS U R I-- 4072 REGISTEJT ARCHIT THO dAS R. HOLLAND STATE OF WASHINGTON REN, 02-18.15 _ l woomm SHEET TITLE GENERAL NOTES SHEETNUNABEK: N-1 REVISION: 0 SE63XC32 THE IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIEiRRY ETY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY 1 T 0) LLI F- 0 fr w F- F- �. f i i;N• ; NIN I �- T1T ry -7 j =r A.4i=N.1A .. m S^If?ACK ; w . z a 1� o M z itiJ 4 w �- f••; �.�.�.'� � EXISTING i SPRINT SITE a EXISTING PARKING r fff' ZONING: BC I J EX STING ✓f BUILDING EXISTING PARKING //-7 f ZONING: BC APN: .= I. 3oao2a-ooss x ✓ O EXISTING BULDING = a o x 0 a o S O EXISTING - DISTRIBUTION d x 0 U� l EXISTING .� . �•-'� OVERHEAD a ITRIWSMISSWN=-� o a =rl5y j�'�s-•.' �; fir. s•;.� 4��_�-• T� � fir: � r �Y ,• tlptizfa ELECT SUBSTATION;4� q 1L TREES�.,x ./ PROPERTY LINE (322.79') EXISTING BUILDING / r EXI571H[i •F .. mis .' EXISTING BUILDING �. // 4• e EXISTING PARKING 7 JS + Ye�.. A GENERAL NOTES THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS, SETBACKS AND EXISTING CONDITIONS ARE APPROXIMATE AND SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. m a > ', DO ! r ` o EXISTING BUILDING f , _ } o � E>[7311ftG � O 'Jir'_ - y EXISTING PARKING - o 71 24"x36" SCALE: 1" = 20'-0" PARCEL PLAN 1 11"x17" SCALE: 1" = 40'-0" 2 0 Tur iKII-Ph—l——NTAINPn IN THIc CPT Ar f'nNSTRLJ(l.TlON nnCL1MFNTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PRD819TTFD. Spri nt);p C OWN ASTL E -ramIC TELECOM YI ES 111 S JACKSON ST, 2ND FLOOR SEATTLE. WA 98104 PROJECT NFORMAl10N: JEFFR.IES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE, 02-25-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITIALS A )1/29/14 ISSUED FOR 90% CONSTRUCTION AF p )2/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICH (SURE 4072TISTERED CHITT THOMAS R. HOLLAND STATE OF WASHINGTON REN. Q2-181 � 9� SHEET TITLE PARCEL PLAN SHEETNUMBER: A-1 REVISION: 0 SE63XC320 21'—S" C-3' (GATE) k k � k X— X— X— X— X— X— X— X— X— X— X— X— X— X— X— X— X -- X x EXISTING SPRINT x EQUIPMENT CABINETS x x m I X Ix ! I I x I o I- 1 1 I I I x x EXISTING 85'-0" I I AGL MONOPOLE _. EXISTING SPRINT ANTENNA ac I I , x LOCATION AT EXISTING MODIFICATION LOCATTIIOND I I EXISTING SPRINT HYBRID CABLE I I x ROUTE I EXIST" SPRINT � I a ICE BRIDGEz I U -s I E X n U 2 N I I I � W I ---- -------------- x I x 1 x � I EXISTING SPRINT x I EQUIPMENT/LEASE AREA AT CONCRETE PAD ON GROUND — x NO PROPOSED MODIFICATION x x I EXISTING OTHER CARIER x EQUIPMENT SHELTER f x x I x x I as x LX�X—X— x—x—x—X—X—X —.X—X X -X- X-X---X-X-X-X-X-x-X---x� 25,-V (EXISTING COMPOUND AREA) 2406" SCALE: 1/2" = 1'-0" 1 11"x17" SCALE: 1ENLARGED SITE PLAN /9' = 1'-0" 2 1' Q 2' — IN—PWATI— r—TAINM IN THIC Rc nr CANSTRIiMONL 00r.[JMFNTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROI.11911ED. Spri nt);o YY acIfflzf5 �-ram PACIT Ic TELECOM SERVICES. LLC 111 5 JACKSON ST. 2ND FLOOR SEATTLE, WA 9Bf04 PROJECT INFORMATION: JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE- O 2 - 2 5 -14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV, GAS2 DESCRIPTION IH1TLQs A 01/29/14 ISSUED FOR 90% CONSTRUCTION AF 0 D2/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 REGISTERED ARC IT T THOiM1AS R. HOLLAND sTATE OF WASH INGTON REM.0som Two willmo SHEET TITLE ENLARGED SITE PLAN SHEETNUMBEIL A —2 REVISION: O SE63XC32Q EXISTING SPRINT POWER CABINET - EXISTING 6'-6" X 12'-0" CONCRETE EXISTING SPRINT HYBRID CABLE R EXISTING SPRINT GPS ANTENNA — EXLSTING SPRINT EXISTING SPRINT BBU CABINET .. EXISTING SPRINT MMBS _. CABINET Ji N IQ NOTE: NO PROPOSED WORK TO EXISTING SPRINT GROUND EQUIPMENT Np� (MSTWG SPRINT LEASE AREA) E%ISi1HC METER BOARD 24"x36" SCALE: 1/2" = r-o• EQUIPMENT PLAN 1 NOT USED 2 11.x17" SCALE: IA' = 1'-0" .2 1 D 2' NOT USED 3 NOT USED 4 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCU6XENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint C �J 111I! ■ ASTLE ;==-ram P IFIC TELECOM SERVICES, LLC Ae111 S JACK SON 5T, 2N0 FLOOR SEA77LE. WA 98104 PROJECT INFORWTION: JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE 02-25-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION A 0'/29/,4 ISSUED FOR 90% CONSTRUCTION 0 2/25/14I ISSUED FOR 100% CONSTRUCTION FGA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICEVSLIRE 4072 REGISTERED AI�CHIT T THOMAS R. HOLLAND STATE OF WASHINGTON REM.6mma SHEET TITLE EQUIPMENT PLAN SHEETNUIMBER- A-3 REVISION: 0 E63XC320 --1 f�\ < 01N A �a•��ly�/, r � 9. 2. 24'e36' SCALE: 1/2" = 1'-O" 11"07" SCALE: 1/4" = 1'-O" /1\ < I� 0_ r �_ 0 1 nl C)IQ L r4�Ar.NC o`o PROPOSED SPRINT e2.5GHz ANTENNA MOUNTED 7 ON EXISTING MOUNT (1 PER SECTOR, 3 TOTAL) PROPOSED SPRINT 5 2.5G1-1z RRH MOUNTED _7 BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) 24"r36` SCALE: 1f2" - 1'-0' ,1_ 1': SCALE: 114" .. 1'-0' 2 1' 2' THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS 0-7 EXISTING EMPTY PIPE MOUNT (TYP) EXISTING W-0' HIGH MDNOPOLE _err EXISTING SPRINT 190OMHz ANTENNA (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 190OMHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) - 'lfc EXISTING ANTENNA PLAN I 1 NOT USED 1 2, NOTE: STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRUS, & NEW CABINETS/TEMPORARY PLATFORM. NOTE: EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE JA',{Wl NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA SIMILAR TO THAT SHOWN ON DETAIL 1, SHEET A-7. -1A�a F r+ FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS. NOTES: AL! A2MWTF6 ARE TD BE E5iABLISHED CipCHWi$£ FROM THE TRUE NORTH HEADWC. f,OT1TRAEI(!R SHALL VERIFY NEW TOANTENNA RAO AEON AND QRANALYIED WITH SPRINT PCS PRIOR IO IkST�ILLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXP611NG TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LIC£H5£D STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO TOWER STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. EXISTING 85'-0" HIGH MONOPOLE w I as z I.-. f gI� EXISTING SPRINT 1900MHz ANTENNA a_ D (1 PER SECTOR, 3 TOTAL) TRUE w4NlK Sri NORTH xvm, Z)� :EXISTING SPRINT 190OMHz RRH tjl MOUNTED BEHIND ANTENNA nib (1 PER SECTOR, 3 TOTAL) JT RRU / HYBRID CABLE SCHEDULE SECTOR RRU MODEL RRU FREQUENCY HYBRID CABLE LENGTH HYBRID CABLE DIAMETER JIJ61P6R SIZE .JUMPER LENGTH RET ILENGTH RET CCALE MANUFACIUR RET CABLE MODEL NUMBER ALPHA RRH-V3 2.5 GHz 120 N/A 1/2" 6' 9.8 COMMSCOPE TCB-B01-006 BETA RR It GHz 120 N/A 1/2' 6' 9.8' COMMSCOPE TCB-B01-006 GAMMA RRH-V3 2.5 GHz 120' N/A 7/2" 1 6' 1 9.8' 1 COMMSCOPE TCB-BOI-006 ANTENNA SCHEDULE SECTOR ANTENNA FREQUENCY ANTENNA MFR. ANTENNA MODEL ANTENNA QUANTITY AZIMUTH RAD CENTER ANT. SIZE ELECT TILT <CH TILT ALPHA 2.5 GHz KMW ET-X-WM-18-65-8P 1 (PER SECTOR) 0' eY-0' BETA 25 GHz KMW ET-X-WM-18-65-BP 1 (PER SECTOR) 120' 61.0" GAMMA 2.5 GHz KMW ET-X-WM-18-65-8P 1 (PER SECTOR) 240- 62-0" 1 61.0" 0- 0- NOTES & ANTENNA SCHEDULE1 4 BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY \U._ G NI 24"x36" SCALE: 3/16" = 1'-O' 11"x17" SCALE:y3r = 1'-0" THE INFORMATION CONTAINED IN 1 INA EXISTING EAST ELEVATION 1 11 x36" SCALE: 3/16' - 1'-0" "x17" SCALE: 3/32" - 1'-0' DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICE$ IS STRICTLY PROHIBITED. 4' �-X ) EXISTING LIGHTNING ROD PROPOSED SPRINT 25GHz ANTENNA MOUNTED 2 ON EXISTING MOUNT 7 (1 PER SECTOR, 3 TOTAL) PROPOSED SPRINT 2.5GFtzBEHIND ANTERRH NMOUNTEDNA 7 5 (1 PER SECTOR. 3 TOTAL) - EXISTING SPRINT 1900MHz ANTENNA (1 PER SECTOR, 3 TOTAL) EXISTING SPRINT 190OMHz RRH MOUNTED BEHIND ANTENNA (1 PER SECTOR, 3 TOTAL) NOTE: STRUCTURAL ANALYSIS MUST BE PREFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRH UNITS, & NEW CABINETS/TEMPORARY PLATFORM, ANALYSIS TO BE PERFORMED BY REGISTERED STRUCTURAL ENGINEER EXISTING OTHER CARRIER ANTENNAS EXISTING SPRINT HYBRID CABLE ROUTE INSIDE MONOPOLE EXISTING 85'-0" AGL MONOPOLE EXISTING SPRINT ICE BRIDGE EXISTING SPRINT EQUIPMENT CABINETS E7051114G CHAIN LINK FENCE GRADE (445' PROPOSED EAST ELEVATION 1 2 a c� r^ z a z z z s w w � z J o z a z o z rn z 0 a Qa w I z M zv�i o I a a ran O w N I tv s9 2— m z O A a is - 0 0 P a O w w U 6 K GRr GHTNING ROD PRINT 190OMHz ANTENNA CTOR, 3 TOTAL) PRINT 190OMHz RRH BEHIND ANTENNA :CTOR, 3 TOTAL) THEIR VTENNAS PRINT BILE ROUTE 40POLE 5'-0" POLE ,PRINT PRINT CABINETS :HAIN E l X -) GHTNING ROD SPRINT TEN NA MOUNTED e IG MOUNT 7 CTOR, 3 TOTAL) SPRINT H MOUNTED 5 TEN NA _7 CTOR, 3 TOTAL) PRINT 190OMHz ANTENNA CTOR. 3 TOTAL) PRINT 1900MHz RRH BEHIND ANTENNA CTOR. 3 TOTAL) AL ANALYSIS MUST BE :D ON ALL ROOFTOPS, AND TOWER SITES ISTALLATION OF NEW NEW RRH UNITS. & NEW TEMPORARY PLATFORM. TO BE PERFORMED BY :D STRUCTURAL ENGINEER. THEIR YTENNAS PRINT BLE ROUTE 40POLE 5'-0" POLE ;PRINT ;PRINT F CABINETS :RAIN :E 24"x36" SCALE: 3/16" = 1'-0" EXISTING NORTH ELEVATION 1 24"x36" SCALE: 3/16" = 1'-0" �� PROPOSED NORTH ELEVATION 2 11N17" SCALE: 3/32" = 1'-O" 1 p 0 4' 11 "x17" SCALE: 3/32" = 1'-0" 4' 2' 0 4 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUViON DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHO, RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint C(( D N -rc ,a Vi11[ 11AL99OU >r cerlcs.. LLc 111 S JACKSON ST. 2ND FLOOR SEATTLE. WA 98104 PROJECT INFORMATION: JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE 02-25-14 ISSUED FOR- CONSTRUCTION DWGS REVISIONS REV, DATE omFwSIl71i INITIALS A ]1/29/14 ISSUED FOR 90% CONSTRUCTION AF 0 02/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072FEKED T T THOMAS R. HOLLAND STATE OF WASHINGTON REN. 02-18+ s SHEET TITLE EXISTING & PROPOSED NORTH ELEVATION SHEETNUMDER A-6- REVISION: 0 .SE63XC32a PANEL ANTENNA WITH MOUNTING HARDWARE ANTENNA PIPE MOUNT, SAMSUNG OR APPROVED EQUAL — RRH MOUNTING HARDWARE, SAMSUNG OR APPROVED EQUAL EXISTING MOUNTING FRAME — NOTE: VERIFY EXISTING CONDITIONS — ALL MOUNTING CLAMPS AND HARDWARE SHALL BE VERIFIED BY TOWER ACCESSORY MANUFACTURER —MOUNTING PIPE (LENGTH TO SUIT) — 2.5 GH2 RRH FIBER & POWER CABLES FIBER & POWER CABLES FROM RF CABINET FIBER FOWEii FIBER & POWER CYLINDERS. CONTRACTOR SHALL MOUNT WITH ADEQUATE HARDWARE TO EXISTING FRAME. JUMPER (TYP.) MANUFACTURER: KMW COMMUNICATIONS MODEL: ET—X—WM-18-65IF, (2.5GH2) WEIGHT: 36.4 LBS DIMENSIONS (LxWxD): 61.0" X 12.0" X 4.3" FREQUENCY: REFER TO RF DATA SHEET 72-0 12.0 or i TOP Itm ?I RF CONNECTOR, TYP — REMOTE ELECTRICAL DOWNTILT ACTUATOR, MECHANICAL DOWNTILT aae11— 4.3 i.1 Facp7Ey prrLp�p to 30 Lack SkM RVA F_ CPYPl.N[J ws • aP. A�ti rZ sle►erq> <i2 � ,oxrNrA. &radEltraDapedlwf 4 moo dM6c. m ]P[Yh ArN s sB[48dF ' 8[rstrar+��i pill 22"x34" SCALE: NOT TO SCALE j 22'x34" SCALE: NOT TO SCALE 22"x34' SCALE: NOT TO SCALE 22' 4' SCALE: NOT TO SCALE i) 11"x17" SCALE: NOT TO SCALE MOUNTING DIAGRAM 1 11N17" SCALE: NOT TO SCALE 2.SGHZ ANTENNA 2 11x17" SCALE: NOT TO SCALE FIBER JUNCTION CYLINDER 3 11"x17" SCALE: NOT TO SCALE POWER JUNCTION CYLINDER i MOUNTING BRACKET 153 AND HARDWARE — SAMSUNG OR APPROVED EQUAL MECHANICAL 5ff.Qw'uohs- ANTENNA MOUNTING PIPE HxWxD: 382x584x240mm ANTENNA (18:6' x15,5"x9.45") n; MOUNTING PIPE}E ...jllll WEIGHT: 59.5 LBS MOUNTING BRACKET nlll AND HARDWARE — i}I �IP�14�lllllil1l �Illiii111111 SAMSUNG OR 9.45 PLAN APPROVED EQUAL F°° y4 O o 7 O 2 K 0 OJ W a MOUNTING BRACKET AND HARDWARE — SAMSUNG OR Lull la Eau 2;10 APPROVED EQUAL 13 ANTENNA MOUNTING PIPE SIDE FRONT 22"x34" SCALE: NOT TO SCALE RRH MOUNTING 4 22"x34" SCALE: NOT TO SCALE 2.5GHZ RRH-V3 5 11N17" SCALE: NOT TO SCALE 11 "x17" SCALE: NOT TO SCALE EQUIPMENT RF—ANTENNA UADU 5) CPRI CABLE 4) FIBER AND DC POWER CABLES JUNCTION 6) JCABLE CYLINDERS I 7) RF JUMPERS � FEEDER LINE GROUND CABLE 3) RRH GROUND CABLE (GROUND GROU DKI OR/8IN. FEEDEMGB 1) MGB GROUND CABLE TGB AND GROUND KIT ARE USED IN CASE OF THE 7/8 N. FEEDER LINE OR MORE 22"x34" SCALE: NOT TO SCALE 22`x3eSCALE: NOT TO SCALE NOT USED 11 N17" SCALE: NOT TO SCALE SAMSUNG MMBS WRING DIAGRAM 6 11"x 17" SCALE: NOT TO SCALE THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROH18TTE0. Spri nt):o� m RN =-ramPA,CIF[C TELECOM VICES, C 111 S JACKSON ST, 2ND FLOOR SEATTLE, WA 90104 PROJECT INFORMATION: JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY. WA 98003 KING COUNTY ISSUE DATE- 02-25-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS R(V. I DATE 13ESCf1vr1 N [1xILL'S A 101/29/14 ISSUED FOR 90% CONSTRUCTION AF 0 2/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4D7�TISTERED CHITT THO S R. HOLLAND STATE OF WASHINGTON REN. 02.18-1 � willillsoo SHEET TITLE: EQUIPMENT DETAILS SHEETNUMBER: A-7 REVISION: 0 E63XC32 TYPICAL HYBRID CABLE COLOR CODE SECTOR FIRST RING SECOND RING THIRD RING A GREEN NO TAPE NO TAPE B GREEN GREEN NO TAPE G GREEN GREEN GREEN FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE FREQUENCY COLOR CODE FIRST RING SECOND RING 1900 MHz YELLOW I RED TYPICAL JUMPER CABLE COLOR CODE FREQUENCY ANTENNA PORT RRU PORT CABLE COLOR 1900 MHz PCS1 -45' ANT 0 BLUE PCS1 +45' ANT 1 WHITE PCS2 -45' ANT 2 GREEN PC32 +45' ANT 3 BROWN RET RET RED NOTES: ON HIGH CAPACITY SITES OR ON FOUR -SECTOR SITES NEEDING AN ADDITIONAL LINE AND RRU CONTACT GDIT SITE SUPERVISOR FOR COLOR CODE INFORMATION ON ADDITIONAL LINES. SL, _cR SAMSUNG FIBEROPTICS ASIA TAI LENGTHI TOTAL WEIGHT WEIGHT LF TOTAL WEIGHT LF TYPE FT G LBS KG LBS KG S KG LBS 60 13 26 0.2 0.5 19 41 0.3 0.7 TYPE 1 75 16 35 0.2 0.5 22 49 0.3 0.7 90 19 42 0.2 0.5 26 57 0.3 0.7 105 30 66 0.3 0.6 29 65 0.3 0.7 120 34 75 0.3 0.6 33 73 0.3 0.7 TYPE a 135 38 85 0.3 0.6 46 101 0.3 0.7 150 43 94 0.3 0.6 51 112 0.3 0.7 165 47 104 0.3 0.6 55 122 0.3 0.7 180 69 151 0.4 0.8 72 160 0.3 0.7 TYPE 3 195 75 164 0.4 0.8 78 173 0.3 0.7 210 80 177 0.4 0.8 85 187 0.3 0.7 225 89 196 0.4 0.9 102 224 0.3 0.7 'YPE 4 240 95 209 0.4 0.9 109 239 0.3 0.7 255 101 222 0,4 0.9 1 115 254 0.3 0.7 133 293 0.5 1.1 122 270 0.3 0.7 141 310 0.5 1.1 152 335 0.3 0.7 YY A330 148 326 0.5 1.1 160 353 E3 0.7 155 342 0.5 1.1 168 371 0.3 0.7 163 359 015 1.1 176 38B TYPE 1 TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 TYPE 7 TOTAL LENGTH "-114'-9,95" -180'-5.35" -213'-3.05" -262'-5.60" "328'-1" -420'-0' -550'-D" HYBRID POWER AWG 10 1 PAIR, AWG 8 1 PAIR, AWG 6 1 PAIR, AWG 6 1 PAIR, AWG 4 1 PAIR, AWG 4 1 PAIR, AWG 2 1 PAIR, CABLE AWG 12 3 PAIR AWG 10 3 PAIR AWG 8 1 PAIR, AWG 8 3 PAIR AWG 6 1 PAIR, AWG 6 3 PAIR AWG 4 3 PAIR CONFIGURATION AWG 10 2 PAIR AWG 8 2 PAIR CABLE DIAMETER 0.98" 1.06" 1.18" 1.18"/1.25" 1.25" L56" 1.69" BENDING RADIUS 11.61" 12.99" 15.35' 17.71' 17.71" 18.00"/30.00' 21.00"/35.00" OPTIC CABLE LC/PC-L9-LC/PC, SINGLE MODE DU CABINET 2 PAIR POWER AND OPTIC CABLE WITH PE PIPE (POWER CABLE TERMINAL MAX SIZE AWG 4) RRU POWER AWG 8, 0.57"-0.60" 8 AWG CABLES 4 PAIRS CABLE SPEC AWC 10, 145"-0.48- NON USE POWER 2 PAIR POWER 2 PAIR POWER 2 PAIR POWER 2 PAIR POWER 2 PAIR POWER 2 PR6i POWER AND OPTIC CABLE O OPTIC .AND OPTIC CAB AND OPTIC CABL .AND OPTIC CAB AND OPTIC CABL 'D On, CA8 PROTECTION WI111 PE PIPE I WITH PE PIPE WITH PE PIPE WffH PE PIPE WITH PE PIPE WITH PE PIPE SUPPLIER TESSC0 TYPE LENGTH TOTAL WEIGHT F7 KG LBS TYPE 8 1 0.73 1.6 1000 732 1613 420 402 887 TYPE 7 1 1 2.2 1000 1006 2218 550 553 1220 22"x34" SCALE: NOT TO SCALE HYBRID AND JUMPER CABLES COLOR CODING 1 22 x34" SCALE: NOT TO SCALE - HYBRID CABLE TYPES 2 11"x17" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE (4) PAIR TO RRU 2" TAPE 2" TAPE 2" SPACE SECOND RING THIRD RING BETWEEN HYBRID 2" TAPE 2" TAPE 2" TAPE 1" SPACE IF APPLICABLE PER 1 SPACE IF APPLICABLE PER CABLE COLOR CODE FIRST RING SECOND RING FIRST RING BETWEEN ( BETWEEN ( AND FREQUENCY FREQUENCY COLOR FREQUENCY COLOR HYBRID COLOR CODE , RINGS SECTOR) RINGS SECTOR) COLOR CODE CODE , CODE (6) FIBER CABLES HYBRID COLOR CODE HYBRID COLOR CODE TAPE (SEE TABLE TAPE [SEE TABLE NO SPACE FREQUENCY COLOR HYBRID COLOR. CODE FOR DETAILS) FOR pETA1LS) BETWEEN CABLE CODE (SEE TABLE TAPE (SEE TABLE FOR DETAILS) FOR DETAILS) 2" TAPE 2" TAPE 2" SPACE BETWEEN HYBRID 2" TAPE 2" TAPE 2" TAPE 1" SPACE SECOND RING 1" SPACE THIRD RING CABLE COLOR CODE FIRST RING SECOND RING FIRST RING BETWEEN ( IF APPLICABLE PER BETWEEN ( IF APPLICABLE PER AND FREQUENCY FREQUENCY COLOR FREQUENCY COLOR HYBRID COLOR CODE RINGS SECTOR) RINGS SECTOR) COLOR CODE CODE CODE (4) PAIR COPPER 111 TO CABINET (6) FIBER CABLES HYBRID COLOR CODE HYBRID COLOR CODE HYBRID COLOR CODE TAPE (SEE TABLE TAPE (SEE TABLE TAPE [SEE TABLE FOR DETAILS) FOR DETAILS) FOR DETAILS) NOTE: 1. ALL CABLES SHALL BE MARKED AT THE TOP AND BOTTOM WITH 2" COLORED TAPE OR STENCIL TAG, COLOR TAPE SHALL BE OBTAINED FROM GRAYBAR ELECTRIC. 2. THE FIRST RING SHALL E CLOSEST TO THE END OF THE CABLE AND SPACED APPROXIMATELY 2" FROM AN END CONNECTOR, WEATHERPROOFING, OR BREAK-OUT CYLINDER, WITH 1" SPACE BETWEEN EACH RING. 3. THE HYBRID CABLE COLOR SHALL BE APPLIED IN ACCORDANCE WITH THE "TYPICAL HYBRID CABLE COLOR CoDE" TABLE ABOVE FOR THE RESPECTIVE SECTOR. 4. INDIVIDUAL POWER PAIRS AND FIBER CABLES SHALL BE LABELED WITH BOTH THE HYBRID CABLE COLOR FOR THE RESPECTIVE SECTOR AND A FREQUENCY COLOR CODE IN ACCORDANCE WITH THE "FREQUENCY COLOR CODE FOR PAIRS AND FIBER CABLES OF HYBRID CABLE" TABLE ABOVE. 5, A 2" GAP SHALL SEPARATE THE HYBRID CABLE COLOR CODE FROM THE FREQUENCY COLOR CODE. 6. THE 2" COLOR RINGS FOR THE FREQUENCY CODE SHALL BE PLACED NEXT TO EACH OTHER WITH NO SPACES. 7. THE 2' COLORED TAPE(S) SHALL EACH BE WRAPPED A MINIMUM OF 3 TIMES AROUND THE HYBRID CABLE OR INDIVIDUAL CABLES, AND THE TAPE SHALL BE KEPT IN THE SAME LOCATION AS MUCH AS POSSIBLE. 8, COLOR BAND ON JUMPERS SHALL BE 2" WIDE WITH A 2" SPACE NO SPACE J �- FREQUENCY COLOR BETWEEN CABLE CODE (SEE TABLE FOR DETAILS) 2" SPACE FROM END OF 2" TAPE RING BREAK-OUT CYLINDER . FIRST RING 2" TAPE RING 2" TAPE RING 1" SPACE SECOND RING 1' SPACE THIRD RING BETWEEN (IF APPLICABLE PER BETWEEN (IF APPLICABLE PER RINGS SECTOR) RINGS SECTOR) HYBRID COLOR CODE HYBRID COLOR CODE WRAP TAPE AROUND TAPE (SEE TABLE TAPE (SEE TABLE CABLE THREE TIMES, FOR DETALS) FOR DETAILS) MIN. (TP) HYBRID CABLE TO CABINET 2" TAPE RING 2" TAPE RING 2" SPACE 1" SPACE SECOND RING 1' SPACE THIRD RING FROM END OF 2" TAPE RING BETWEEN (IF APPLICABLE PER BETWEEN(IF APPLICABLE PER BREAK-OUT CYLINDER, FIRST RING RINGS SECTOR) RINGS SECTOR) HYBRID COLOR CODE TAPE (SEE TABLE HYBRID OR CODE TAPE (SEE TABLE WRAP TAPE AROUND CABLE. THREE TIMES, FOR DETALS) FOR DETAILS) MIN. (TYP) 2' TAPE 2' TAPE 2' SPACE SECOND RING FIRST RING BETWEEN CABLE COOE FREOU NCY COLOR FREQUENCY COLOR AND FREQUENCY CODE CODE COLOR CODE HYBRID CABLE TO RRU - 2" TAPE THIRD RING CABLE A t' SPACE 2 FROM RRU ANTENNA END OF JUMPER 2" SPACE 2" TAPE 2" TAPE 2" TAPE BETWEEN CABLE CODE FIRST RING SECOND RING THIRD RING AND FREQUENCY FREQUENCY COLOR FREQUENCY COLOR CABLE y COLOR CODE CpOE CODE RRU & END FROM ANTENNA OF JUMPER JUMPERTEN I N AT RRU AND ANTIFININA 22"x34" 3 HYBRID CABLE COLOR SCHEME DE -TAIL 11"x17" SCALE: NOT TO SCALE SCALE: NOT TO SCALE THE INFORMATION CONTALNED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED, Sprint 1 C(m YL� p4ClE IC TELECOM RVIC ES, LLC 111 5 JACKSON ST, E2ND FLOOR SEATTLE. WA 95104 PROJECT INFORLMATION: JEFFR.IES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUEDTTE 02-25-14 ISSUED FORzCONSTRUCTION DWGS REVISIONS REV. DATE DESCRIPTION INITq S A 01/29/14 ISSUED FOR 90% CONSTRUCTION AF p )2/25/14 ISSUED FOR 100% CONSTRUCTION GAP NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 07REGISTERED ART ZT,11OMAS R. HOLLAND TE OF WASHINGTON REN. 02.181 r _ l � l SHEET TITLE ANTENNA AND CABLE COLOR CODING DETAILS SHEETNUMBER R-F-1 EE63XC,32 1 CONNECTION FROM EXISTING SPRINT ANTENNA GROUND BARS TO EXISTING MASTER GROUND BAR CONNECTION OF SPRINT ANTENNA MOUNTING PIPE TO EXISTING ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL) CONNECTION OF SPRINT RRU TO EXISTING ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL) LEGEND ■ EXOTHERMIC CONNECTION f.T MECHANICAL CONNECTION COMPRESSION CONNECTION CGB COLLECTOR GROUND BAR MGB EXTERNAL GROUND BAR 24"x36" SCALE: 1/2" = 1'-O' 11"x17" SCALE: 1/4' - 1'-0' NOT LISED 2 CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH EXISTING FINAL GROUND LEAD FROM MASTER GROUND BAR TO EXISTING MONOPOLE GROUND RING EXISTING SPRINT MASTER GROUND BAR AT GROUND LEVEL EXISTING SPRINT ANTENNA GROUND BAR (1 PER SECTOR, 3 TOTAL) TRUE UAcryiR: e .mw #*M a� ANTENNA SCHEMATIC GROUNDING PLAN I 1 NOT USED 1 3 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC CONDITIONS. 2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW ANTENNA AND BTS MANUFACTURERS PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES. 3. ALL GROUND CONNECTIONS SHALL BE EXOTHERMIC. ALL WIRES SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND, 4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE GROUNDING AND OTHER OPERATIONAL TESTING WILL BE WITNESSED BY SPRINT WIRELESS REPRESENTATIVE. 5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY WITH ALL REQUIREMENTS OF GROUNDING STANDARDS. 6. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM PER SPRINT STANDARD GROUNDING METHOD, AND RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT WIRELESS REPRESENTATIVE, PRIOR TO INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL EXOTHERMIC AND GROUND RING 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. & ALL EXITING GROUND BARS, WIRES ✓4 CONNECTIONS SHALL BE FIELD VERIFIED. ANY DEFICIENT ITEMS SAkl L BE REPLACED AS REQUIRED TO ACHIEVE ADEQUATE GROUNDING REQUIRED BY SPRINT. I GENERAL GROUNDING NOTES GROUNDING NOTES 1. EXOTHERMIC WELDS (2). 2 AWG BARE TINNED SOLID COPPER CONDUCTORS TO GROUNDING BAR. ROUTE CONDUCTORS TO BURIED GROUNDING RING AND PROVIDE PARALLEL EXOTHERMIC WELD. 2. EC SHALL USE PERMANENT MARKER TO DRAW THE LINES BETWEEN EACH SECTION AND LABEL EACH SECTION ('P". "A", 'N", "I-) WITH 1" HIGH LETTERS 3 ALL HARDWARE 16-3 STAINLESS STEEL, INCLUDING LOCK WASHERS, COAT ALL SURFACES WITH AN ANTI -OXIDANT COMPOUND BEFORE MATING. ALL HARDWARE SKALL BE STAINLESS STEEL 3/6 INCH DIAMETER OR LARGER. 4. FOR GROUND BOND TO STEEL ONLY: INSERT A CADMIUM FLAT WASHER BETWEEN LUG AND STEEL. COAT ALL SURFACES WITH AN AND -OXIDANT COMPOUND BEFORE MATING 5. NUT & WASHER SHALL BE PLACED ON THE FRONT SIDE OF THE GROUNDING BAR AND BOLTED ON THE BACK SIDE. INSTALL BLACK HEAT -SHRINKING TUBE, 600 VOLT INSULATION ON ALL GROUNDING TERMINATIONS, THE INTENT IS TO WEATHERPROOF THE COMPRESSION CONNECTION. & NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER. ANTENNA LOCATION, AND CONNECTION ORIENTATION PROVIDE AS REQUIRED. 7. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. & WEATHERPROOFING SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 9, SUPPLIED AND INSTALLED BY CONTRACTOR 10. WHEN THE SCOPE OF WORK REQUIRES THE ADDITION OF A GROUNDING BAR TO AN EXISTING TOWER. THE SUBCONTRACTOR SHALL OBTAIN APPROVAL FROM THE TOWER OWNER PRIOR TO MOUNTING THE GROUNDING BAR TO THE TOWER. 11. EXTEND TWO (2) 2 AWG TINNED CU CONDUCTOR FROM BURIED GROUNDING RING AND CONNECT TO THE NEW TOWER. FOLLOW MANUFACTURERS RECOMMENDATIONS FOR GROUNDING CONNECTIONS TO THE TOWER. (APPLICABLE TO NEW TOWERS ONLY,) 12. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATION. AND CONNECTION ORIENTATION. THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ADDITIONAL GROUNDING BARS AS REQUIRED, PROVIDING 50% SPARE CONNECTION POINTS 13. EXPOSED GROUND WIRES TO BE NON METALLIC LIQUID TIGHT, CARRIER SERVICES IS STRICTLY ANTENNA $ECiOR I EXISTING PROPOSED 1900 MHz 2.5 GHz ANTENNA ANTENNA EXIST. CGE1 I HYBRID CABLE INTERNAL GRID WIRE TO BE TRIMMED TO FIT AND ATTACHED TO GRID BAR I 1.0 AWG R w .. (E)___#2 AWG JUMPER ANTENNA SECTOR 2 EXISTING PROPOSED 1900 MHz 2.5 GHz ANTENNA ANTENNA or --I Al— I CIST. CGS IUNCTIQN h'LINDERS I 1 (E) HYBRID MEDUSA COAX JUMPER �. �10 #,D AWG I HYBRID CABLE INTERNAL GRD WIRE TO BE TRIMMED TO FIT AND ATTACHED TO GRD BAR W (E) HYBRID m MEDUSA (E) #2 AWG G U V [} EXISTING UPPER rF & ¢ TOWER GROUND BAR m m } x i x z z z z n >C W D z R W Z z R CIST. CGB _ `JUNCTIGNT CYLINDERS I I _(E) #2 AWG_ _ AN NNA CiOR 3 EXISTING PROPOSED 1900 MHz 2.5 GHz ANTENNA ANTENNA 3 a HYBRID CABLE INTERNAL at GRD WIRE TO BE I TRIMMED TO FIT AND ATTACHED TO GRD BAR (E) HYBRID MEDUSA JUMPER CYLINDERS LEGEND ■ EXOTHERMIC CONNECTION ❑ MECHANICAL CONNECTION o COMPRESSION CONNECTION CGB COLLECTOR GROUND BAR MGB EXTERNAL GROUND BAR GROUNDING NOTES 1• ALL GROUNDING CONNECMINS SHALL Be MADE SY MECHANICAL CONNECTION, ALL CABLE TO GROUND RQOS, CROUNO RODS SP❑CES AND LIGHTING PROTECTIONS SYSTEM AS INDICATE4. CROUTtD FOUNDATION ONLY AS INDICATED BY PM. ALL MATERIALS USED SHALL BE INSTALLED PER EXISTING MANUFACTURERS RECOMMENDATIONS AND PROCEDURES GROUND EXISTING DEI EXISTING MMBS EXISTING GPS CABINET CABINET _ CABINET HYBRID CABLE CONDUCTOR SHALL HAVE A MINIMUM 24� BENDING RADIUS ANTENNA INTERNAL GRD WIRE 2 ALL MECHANICAL CONNECTIONS ON GALVANIZED SURFACES SHALL BE TO BE TRIMMED TO CLEANED THOROUGHLY AND COLORED TO MATCH SURFACE WITH (2) TWO FIT AND ATTACHED COATS OF GALVITE (WHITE) PAINT, OR SILVERBRITE (ALUMINUM)• #6 AWG WITH TO GRD BAR WEATHERPROOFING 3. ALL ELECTRICAL & MECHANICAL GROUND CONNECTIONS SHALL HAVE — ANTIOXIDANT COMPOUND APPLIED TO CONNECTION. _(E 2 AWG LD [D o 4. GROUND TESTS SHALL BE PERFORMED AS REQUIRED BY SPRINT 3a 3 Z 3 STANDARD PROCEDURES. GROUND GRID RESISTANCE SHALL NOT EXCEED COAX ¢o exQ o m 5-OHMS. rl� I3 & 5. CONTRACTOR SHALL SUBMIT THE GROUND RESISTANCE TEXT REPORT AS EUU85 GND BA #2 AWG R FOLLOW: 1 2 AWG MGB G 1. ONE (1) COPY TO OWNER REPRESENTATIVE 2. ONE (1) COPY TO ENGINEER 3. ONE (1) COPY TO KEEP INSIDE EQUIPMENT INCLOSURE ISTINO LOWER 6. ALL RADIO EQUIPMENT AND UTILITY CABINETS GROUNDS LEADS TO BE #2 TOWER GROUND BAR AWG STRANDED GREEN JACKETED FROM BUSS TERMINAL I I I I I 7. ALL ANTENNA MOUNT GROUNDS SHALL BE #2 AWG STRANDED GREEN JACKETED CABLE GROUNDS SHALL BE BLACK FROM MFR ? I 8. ALL GROUND WIRES GROUND BARS TO GROUND SHALL BE #2 AWG SOLID AS REQUIRED. 0 01 9. ALL ABOVE GROUND WIRES SHALL BE GREEN JACKETED. ALL GROUND ¢I 2 AWC WIRE'S PENETRATING INTO GROUND AND BELOW SHALL BE SOLID BARE cD TOWER GROUNDING STAN6ARD x 1 1. EXISTING HOME RUN GROUND WIRES TO BE REMOVED. 2. ALL EXISTING AND EXISTING TOWER GROUND BARS TO BE MECHANICALLY ATTACHED TO TOWER WITHOUT INSULATORS EXISTING #2 AG #2 AG GROUNDS TO EXISTING GROUNDS TO EXISTING 3, NO DRILLING OR WELDING TO TOWER PERMITTED. GROUNDS TO �X�STINGGROUND RING GROUND RING 122"x34" SCALE: NOT TO SCALE 11x17" SCALE: NOT TO SCALE THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE- ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES 19 STRK.°RY PROHIBITED. GROUNDING RISER DIAGRAM I 1 Sprint -LIO N CIS L E F=-rES IACIi1C TELEC 41 ICES, i C 111 S JACKSON ST, E2ND FLOOR SEATTLE, WA 9B104 PROJECT INFORNLAMON JEFFRIES SE63XC320/ CROWN 880427 29205 18TH AVE S FEDERAL WAY, WA 98003 KING COUNTY ISSUE DATE 02-25-14 ISSUED FOR: CONSTRUCTION DWGS REVISIONS [REV. DATE DESCRIPTION IGA 1/29/14 ISSUED FOR 90% CONSTRUCTION .t250 4 ISSUED FOR 1007 CONSTRUCTION NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE 4072 E�EGISTERED ARCHIT CT THOMAS R. HOLLAND STATE OF WASHINGTON REN,-0- ION _ l SHEET TITLE GROUNDING DETAILS SHEETNUMBER: REVISION: 0 E-2 E63XC32 N►. 22'x34' SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE 22'x34' SCALE: NOT TO SCALE 11"x17" SCALEr NOT TO SCALE IE INFORWaTION CONTAINED IN THIS SET OF NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE ANDREWS. (TYPE & PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER.) TO ANTENNAS RXO CONNECTOR WEATHERPROOFING KIT j7YP.) SEE ROTE 2� #2 AWG STRANDED. INSULATED BONDEQ TO TOWER STEEL OR MCNOPOLE— NOT LISED 1 22 x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE / KIT (TYP.) / STANDARD GROUND KIT (TYP.) (SEE DEF/3 E-5) ANTENNA CABLE TO SHELTER (TYP.) �M AENNA GROUND AWG W. SWILAR TO 106-057. MOUNT GROUND BAR NEAR TOP OF MONOPOLE, TOWER OR WAVEWME LADDER. 12 ANTENNA CABLE WEATHERPROOFING KIT �2 1/2"0 MAX. (SEE NOTE 3) CABLE GROUND KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) CQNNE TC N OF CABLE (;ROUND KIT TO ANTENNA CABLE NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KR SHALL BE ANDREW SUREGROUND TYPE KIT WITH TWO —HOLE LUG. 3, WEATHER PROOFING SHALL INCORPORATE PPC WEATHERPROOFING TAPE KIT, COLD SHRINK SHALL NOT BE USED. INSPECTION WINDOW REQUIRED FOR BUTT CONDUCTOR ALL INTERIOR INSULATION UP tpm TWO —HOLE AGAINST THE 4EAD CONNECTORS CONNECTOR 7RRf7x1' MIN O4 FLKrT 22"x34' SCALE: NOT TO SCALE 22x34" SCALE: NOT TO SCALE ANTENNA GROLIND BAR 2. 1"xl7" SCALE: NOT TO SCALE CABLE GROUNDING 131 ll"xl7" SCALE: NOT TO SCALE STRANDED CU WIRE WITH GREEN, 60OV, THHN/THWN INSULATION. SIZE AS SPECIFIED GROUND BAR ON ANTENNA TOWER O O O D a 0 O O O TWO —HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4'5TA1NLE55 STEEL liE% HEAD BOLTS AND HARDWARE, TYPICAL MECHANICAL CONNECTIONS 15 22 x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE STRANDED CU WIRE WITH GREEN, 60OV, THHN/THWN INSULATION. SIZE AS SPECIFIED #6 AWG GREEN STRANDED CU GROUNDING CONDUCTOR FROM RRU UNIT TO #2 AWG GROUNDING CONDUCTOR � ri T`1 T-1 GROUND BAR ON WALL, FLOOR OR ON ANTENNA TOWER — THIN WALL C—TAP Wj DYE INDEX (SEE NOV #2 AWG STRANDED C GROUNDING CONDUCTOR NOTE, CONTRACTOR TO SURROUND COMPLETED CONNECTION W/ WEATHER PROOFING TAPE TO ENSURE WEATHER PROOF CONNECTION. GROUND LEADS TO NEW PIPE MOUNT, NEW SPRINT ANTENNAS & NEW SPRINT RRU'S COAX CABLE GROUND LEADS O O O O EXISTING 4"xl2"xl/4" THK., O Q O O TINNED GROUND BAR & CONNECTIONS. O O O O O O O EXOTHERMIC WELD WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 60OV, THHN/THWN INSULATION TO MGB GROUND LEADS TO EACH ANTENNA GROUND BAR CLEAR IASKT/ SHRINK TINNED COPPER GROUNDING BAR S/S FLAT WASHER S/S BOLT (1 OF 2) "DO NOT DISCONNECT' TAG ON ALL GROUND BAR INTERCONNECTS AND EQUALIZERS — 1/4" MIN HEAT SHRINK TWO HOLE LLIG 1 4 NOTE: .PROVIDE NO—OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR ANTENNA GROUND BAR CONNECTIONS 6 NOTE: •PROVIDE NO—OX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR COAX CABLE GROUND LEADS • LINNI•, • • • • • •• • • • • • • •1 • • • • • • • • • • • • •• • • • • • • • • • • • •• • • • • • • • • • • • • • • • • 22"x34" SCALE: NOT TO SCALE Q 22"x34" SCALE: NOT TO SCALE NOT USED 7 "x17" SCALE: NOT TO SCALE C-TAP CONNECTION O "x17" SCALE: NOT TO SCALE DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SCR l IS STRICTLY PROHIBITED. L TWO —HOLE LUG, BOLTED TO GROUND BAR USING 3/8"-16 x 1 1/4-STAINLESS STEEL HEX HEAD BOLTS AND HARDWARE. EXOTHERMIC WELD WITH #2 AWG SOLID TINNED BARE CU WIRE OR STRANDED CU WIRE WITH GREEN, 50OV, THHN/THWN INSULATION TO ANTENNA STRUCTURE, BUILDING, RING GROUND OR MGB EXISTING GROUND BAR & CONNECTIONS ' GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC CONNECTION. TOWER MASTER GROUND BAR CONNECTIONS 9