Loading...
17-104663CITY OF ti. Federal Way October 20, 2017 Natalia Jepsen MD7, LLC 10590 W. Ocean Air Drive, Suite 300 San Diego, CA 92130 i jepsen&07.com RE: File 917-104663-00-UP; PROCESS I —'DIRECTOR'S APPROVAL' Sprint - SE63XC320 Jefferies, 29205 181h Avenue South, Federal Way Dear Ms. Jepsen: CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www. cityoffederalway.. com Jim Ferrell, Mayor The City of Federal Way's Department of Community Development has completed an administrative review of the proposed eligible facilities request to modify an existing Personal Wireless Facility (PWSF) located at the above -mentioned address. The proposed modifications include the removal of six antennas, installation of three antennas, and installation of auxiliary equipment on a custom steel monopole. No modifications to the existing ground equipment are being proposed. The Process I application was submitted and determined to be complete on September 29, 2017. The eligible facilities request is found to be consistent with the provisions of the Spectrum Act and does not exceed the substantial change thresholds. The Process I proposal is hereby approved based on the following statements of fact: Criteria 1 For facilities outside of public rights -of -way, the modification does not increase the height of the tower by more than 10%, or by the height of one additional antenna array with separation from the nearest existing antenna not to exceed twenty feet, whichever is greater. Staff'Response —There is no height increase. This criterion is met. Criteria 2 For structures outside of public rights -of -way, the modification does not protrude from the edge of the structure more than 20 feet, or more than the width of the structure at the level of the appurtenance, whichever is greater. Staff Response — Based on the elevation and site plan there is no increase in the width of the structure. This criterion is met. Criteria 3 If the installation includes new equipment cabinets, the modification does not include the installation of more than four equipment cabinets. Staff'Response —No new equipment cabinets are proposed. "Phis criterion is met. Ms. kipsen October 20. 2017 Page 2 Criteria 4 For all existing facilities, the modification does not include excavation or equipment installation outside the current site of the structure or base station. Staff Response —No excavation or equipment will be instal led outside the current site of the structure or existing base station. This criterion is met. Criteria 5 If the facility requires screening methods, the proposed modification does not defeat the existing concealment elements of the tower or base station. StafResponse — Current screening methods are not defeated as a result of this proposal_ Criteria 6 The modification may not violate any of the conditions of approval associated with prior approvals. StcrResponse — The proposal does not violate any known conditions associated with prior approvals of the tower or site. This criterion is met. PERMIT ISSUANCE REQUIRED Prior to any site work, the applicant shall obtain an electrical permit fi-om the City's Building Division. For further information regarding the electrical permits, please contact the department's Permit Center at perm itcenter& ityoffedera I way. corn or 253-835-2607. CLOSING This decision shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this site. This Process I approval does not constitute approval of an electrical permit. The effective date of this decision is October 23, 2017, or three days from the date of this letter. Pursuant to FWRC 19.55.050, any person who received notice of this administrative decision may appeal the decision to the Federal Way Hearing Examiner by November 6, 2017. Any appeal must be in the form of a letter delivered to the Department of Community Development with the established fee. The appeal letter must contain a clear reference to the matter being appealed and a statement of the alleged errors in the Director's decision. No work on the proposal can commence until the end of the appeal period. In that you are the only party of record, you may waive your right to appeal by submitting a letter to this effect to the City of Federal Way, Department of Community Development. Waiver of the right to appeal does not affect the effective date of this decision. Work on the site may not commence until you have been issued the appropriate electrical permit. Per FWRC 19.15. 1 00(l), this Process I approval is valid for one year from the effective date of this decision. If no further action is taken within one year, this decision will expire. A one-year extension of time may be granted only if a written request is submitted to the City's Department of Community Development at least 30 days prior to the expiration of the decision pursuant to FWRC 19.15.110. 17-104663-00-UP Doc I D 76714 Ms. ,lapsen October 20' 2017 Page 3 If you have any questions regarding this decision, please contact Associate Planner Becky Chapin at 253- 835-2641 or becky.chapin@cityoffederalway.com. Sincereiy, I 1 Brian Davis -9hbrr Community Development Director enc: Approved Site Plans/Elevations 17-104663-00-UP Doc. I,D 76714 C' G' d d"' September 21, 2017 To: City of Federal Way Department of Community Development 33325 8th Avenue South City of Federal Way, WA 98003 From: Kathleen Doan -Ha 10590 W Ocean Air Drive, Suite 300 San Diego, CA 92130 858.964.7430 kdoanhaf@md7.com Re: Site ID SE63XC320 — 29208 18th Avenue South Hello, RECE WED SEP 2 9 2017 co uNi-Y GV��o E� Please find the following documents enclosed for the Building Permit application for Sprint to upgrade its existing wireless communication facility located at 29208 18th Avenue South, Federal Way, WA 98003: 1. (1) Check for $121.47 2. (1) Project Narrative 3. (1) Submittal Requirements for Process 1 4. (1) Master Land Use Application 5. (1) Copy of leases 6. (1) Email Authorization from Puget Sound Energy 7. (1) Letter of Authorization from Sprint 8. (4) Sett of Construction Drawings Thank you for your time and efforts. Sincerely, r Kathleen Doan -Ha Land Use M D7, LLC Kathleen Doan -Ha From: Gasser, Timothy <tim.gasser@pse.com> Sent: Thursday, August 24, 2017 11:22 AM To: Arnold, Sarah Cc: McDowell, Marianne; Somers, Jan [CTO]; Martin, Bill Subject: Review of Sprint's Site Modification request for Jefferies (aka Marine View Substation / (SE63XC320) - 800 Mhz Sarah, Sprint's Site Modification request for Jefferies (aka Marine View Substation / (SE63XC320) involves the replacement of three (3) existing Andrew model HBXX-9014DS-A2M antenna with three (3) new KMW model ETCR-654L-12H6 antenna. Six (6) new Samsung model 800 Mhz RRU modules will be added to the six (6) existing Samsung modules. Three (3) new RFS filters and one (1) new 1— 7/16" hybrid cable will also be added. Additional RRH modules and new filters will be installed on a new mount assembly below existing mount. No changes to ground equipment. Site is a custom steel monopole managed by Crowncastle. Sprint's request is approved with the following conditions; 1) Sprint shall be responsible for structural review of the pole and new design to confirm the pole will support the increased loading. 2) Final CD's showing location and design of equipment mounting. 3) Execution of a new SLA, under the new template. (Note 1) 4) Final As -Built drawings and closeout photos from this project shall be provided upon completion of the work. As with all proposals, final approval is subject to: PSE's review and approval of final, jurisdictional approved site drawings; structural review; site lease amendment; landscape review and maintenance agreement if relevant; PSE's receipt of Sprint's NTP letter and procurement of all applicable permits. Please provide us with'any applicable revisions and permits/approvals as they are acquired. Note 1— If not already issued under new template. Otherwise will be replacement of Site Description Addendum page. Timothy Gasser Senior Project Manager, Wireless Collocation Communication Sitings & Services Puget Sound Energy (425) 456-2776 - office (206) 947-0335 - mobile 0 PUGET SOUND ENERGY The Energy Tb Do Groat Things Site License Addendum to Master License Agreement for Location of Facilities STC FIVE LLC — Marine View Substation — Tower Only site This Site License Addendum ("SLA"), dated as of , 2013, is made by and between Puget Sound Energy, Inc., a Washington corporatioH ("PSE"), and STC FIVE LLC, a Delaware limited liability company ("STC FIVE"), with reference to that certain Master License Agreement for Location of Facilities, dated April 5th, 2011, between PSE and STC FIVE (the "MLA"). In connection with the MLA, the Parties have agreed to incorporate and make a part of the MLA the terms set forth in this SLA. All capitalized terms not otherwise defined in this SLA will have the meanings set forth in the MLA. Section 1. Description of Site. The following Site(s) will be covered by this SLA: The site is located at PSE's Marine View Substation, located at 29305 18th Avenue South, Federal Way, WA. This is an existing steel pole tower site. STC FIVE equipment at the site includes the free standing steel poll tower and fence which surrounds the wireless equipment, owned by third parties under separate SLAB, on PSE property. See PSE approved drawings. Section 2. Equipment. The permitted Equipment for the Site(s) covered by this SLA are: See attached Appendix 1 Section 3. Site Development Plan. The Site Development Plan for the Site(s) covered by this SLA is as follows: See attached Appendix 2. Section 4. SLA Term. The SLA Term for this SLA will be as set forth in Section 16.1 of the MLA based on the following SLA Commencement Date: SLA Commencement Date: 1 Section 5. Compensation. The Annual Fees and other amounts payable by STC FIVE in connection with the Site(s) covered by this SLA will be as follows: a See attached Appendix 3. Section 6. Additional Terms As conditions to approval of this Permit, the following also apply: STC FIVE LLC Marine View Substation — Tower Only site BY: (W604s Daw_&j aj ooCTjrPa BUN: - aKZ7 LeasWU 3440 6�l 6.1 STC FIVE shall provide complete, detailed, jurisdictionally approved final construction drawings before construction begins for PSE's review and approval. Said drawings shall show in detail the following: 6.1.1 Grounding design of equipment and fencing in accordance with the National Electrical Safety Code provisions in Section 9, and PSE's design policies. 6.1.2 Location of the telephone source and/or telephone cable installation from source to the equipment cabinets. 6.1.3 Field verification and staking of the location of steel pole, fencing and of property lines establishing that proposed facility location lies as noted, 6.1.4 Appropriate separation distance between any part of STC FIVE's facilities and the nearest electrical conductor, 6.1.5 Attachment of all antennas, equipment and cabling to the pole, and 6.1.6 If relevant, landscape design showing acceptable vegetation compatible with electrical facilities and/or substations. 6.2 Any comments and conditions noted during PSE's review process, including: 6.3 No construction shall commence prior to the receipt and written approval by PSE of the final construction drawings and evidence of authorization by all governmental agencies having jurisdiction over the project. An on site pre - construction meeting shall be scheduled prior to construction and as -built drawings and color photos showing the completed installation (pole and base equipment) shall be provided after completion of construction. 6.4 If a PSE pole or any of its facilities are required and are to be located on private property for which PSE does not have an existing, or adequate easement, then STC FIVE will need to acquire this new easement for PSE prior to construction. 6.5 Where PSE shall install a HH or other facilities related to NCC in right-of-way (ROW) in order to provide electrical service to this site, STC FIVE shall be responsible for the cost of relocating such facilities, should it be required as the result of any jurisdictional directed improvement or relocation. 6.6 STC FIVE shall be responsible for structural review of the steel pole tower and any future modifications and/or attachments to confirm the pole will support current and/or future loading. 6.7 No digging or trenching on PSE property without express approval from PSE. 6.8 Advance notification prior to any site access. All work on PSE facilities shall be performed by PSE designated personnel. Any work or activity that impacts the area within the fenced area of the substation, including the air space above the station, along with all necessary outages, shall be coordinated and approved by PSE. STC FIVE LLC Marine View Substation - Tower Only site Depending on the time of year, scheduling of outages, if required, may cause unforeseen delays in the construction and/or maintenance of the facility. 6.9 STC FIVE, equally and in partnership with the other wireless leasees at this location shall be responsible for the maintenance of all jurisdictionally mandated additions to the site's landscaping and for vegetation control of the lease area. PSE reserves the right to perform such maintenance activities, with STC FIVE responsible for its proportional share, should PSE determine that landscape maintenance is required and no action has occurred within 30 days of notice of their requirement by PSE. PSE shall institute a Site Landscape Maintenance Agreement, to include all wireless leasees at this location. Failure to enter into such an Agreement shall be cause for termination of this permit. 6.10 STC FIVE shall provide PSE a copy of the requirements for the steel pole tower including antenna types, sizes and loadings, mounting hardware attachments for antenna mountings, locations of all antenna and cabling and any other requirements. STC FIVE shall be responsible for structural review of the steel pole tower. PSE will also determine the area available, if any, for STC FIVE's use. In the event PSE decides that the space required by STC FIVE cannot be provided, or that due to construction, policy or outage concerns siting a PCS facility is not suitable, PSE may withhold site approval. Section 7. Miscellaneous This SLA, and the use of the Site(s) covered by this SLA, will be governed in all respects by the terms and conditions set forth in the MLA, as supplemented by this SLA. In the event of a conflict between the terms and conditions of this SLA and the terms of the MLA, the terms of the MLA will govern and control. The terms and conditions of the MLA, as supplemented by this SLA, set forth the entire agreement between STC FIVE and PSE with respect to the Site(s) covered by this SLA. STC FIVE LLC Marine View Substation - Tower Only site STC FIVE: STC FIVE LLC By: GLOBAL SIGNAL ACQUISITIONS II LLC As its: Attorney in Fact � 7 B- -��� r= , PSE: Puget Sound Energy, Inc. By: Brett Bolton Lisa A. Sed wick Print Name REI manager Its: Manager, Real Estate Its: Date Signed: Address: STC Five LLC c/o Crown Castle USA Inc. E. Black Hawk, General Counsel 2000 Corporate Drive Canonsburg, PA 15317 Attn: Legal Department STATE OF A - Date Signed: ?fh I I� Address: P.O. Box 97034 Bellevue, WA 98009-9734 Attn: Joint Use Department COUNTY OF ) On this day , 2013, before me, a Notary Publi in and for the State of 1 commissioned and sworn personally appeared 1 to me Hawn to be the -PI1T at, Global Signal Muisitions II LLC that executed the foregoing instrument and ujnowledged the same to be the free and voluntary act and deed of said corporation, for the uses and purposes therein mentioned, and on oath stated that he/she is authorized to execute the said instrument. Witness my hand and official seal hereto affixed the an ear in this certificate above written. "l KARINA ANGUIO r: Notary PUbilc, Sto1e of TeXaS A4yCommisslonExpires Print Naive: via ID AIL;> September 19, 2016 ry,��„,•• Notary Public in and for the fate off, Residing at -rw My commission expires STC FIVE LLC Marine View Substation - Tower Only site 4 PV'3ET SDUND ENERGY PERMIT FOR LOCATION OF FACILITIES SPRINT SPECTRUM — MARINE VIEW SUBSTATION — PSE - #SE63XC320 This Permit, dated as of tMtY Z 4P , 2004, is made by and between Puget Sound Energy, a Wa gton corporation ("PSE"), and Sprint Spectrum L.P., a Delaware limited partnership ("Sprint Spectrum"). PSE and Sprint Spectrum are at times referred to herein where appropriate individually as a "Party" and collectively as the "Parties". The Parties agree as follows: 1. Permit. For and in consideration of the mutual benefits to be derived therefrom, PSE hereby grants permission to Sprint Spectrum, subject to the terms and conditions of this Permit, to use the real property described in the attached Appendix 1 (the "Site"). The rights and obligations of Sprint Spectrum arising under this Pen -nit will apply to and be binding upon Sprint Spectrum's officers, employees, agents and representatives, and its suppliers and subcontractors of any tier acting on behalf of Sprint Spectrum in connection with the performance of the Work (as defined below) or this Permit (collectively, the "Support"). Sprint Spectrum shall be solely responsible for the performance, nonperformance, acts and omissions of its Support. 2. Use of the Site. Sprint Spectrum shall have the right to use the Site for the purpose of undertaking the following activities (the "Permitted Activities"): 2.1 installation, operation and maintenance of the equipment specified in the attached Appendix 2 (the "Equipment") in accordance with the site development plan attached hereto as Appendix 3 (the "Site Development Plan") and all other provisions of this Permit; and 2.2 performance of the installation, maintenance, repair, relocation, removal and other work specified in the Site Development Plan (collectively, the "Work") in accordance with the Site Development Plan and all other provisions of this Permit; and 2.3 obtaining, at Sprint Spectrum's sole cost and expense, telephone service from any utility company that provides such service to the Site, and arranging for the installation of a separate meter and main breaker, subject to PSE's right to approve the exact location of proposed utility routes and the manner of installation; and 2.4 access to and from the Site for purposes of undertaking the activities specified in paragraphs 2.1, 2.2 and 2.3, in accordance with the following: Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEAI23) Page 1 2.4.1 access for construction, routine maintenance and repair and other non -emergency visits shall only be during normal business hours (defined as Monday through Friday, 8 am to 6 pm) unless otherwise agreed upon by the Parties; 2.4.2 in the event of emergency, Sprint Spectrum may access the Site twenty-four (24) hours per day, seven days per week, by calling the PSE emergency telephone number set forth in paragraph 7 and requesting such access; 2.4.3 access to the Site may be by foot or motor vehicle, including trucks; and 2.4.4 access to the Site shall be subject to such reasonable conditions as maybe imposed by PSE from time to time. 3. Limitations on Use. Except and only as specifically authorized in paragraph 2, Sprint Spectrum shall not enter upon the Site or make any use thereof. Without limiting the generality of the foregoing: 3.1 Sprint Spectrum shall, at all times, undertake the Permitted Activities in a manner so as to prevent bodily harm to persons (whomsoever) and damage to property (whatsoever). Precautionary measures shall include, without Iimitation, reasonable site security measures (e.g., fencing, signage, lighting, security guards, etc.) necessary to prevent access to the Site during such times as the Permitted Activities may cause the Site to be in an unsafe or unsecured condition. 3.2 Sprint Spectrum shall, at all times, undertake the Permitted Activities in a manner that does not disturb or interfere in any way with the operations of PSE or any prior existing users of the Site, or otherwise in a manner that would impair the safe, continuous and reliable operation of PSE's utility systems or improvements. Without limiting the generality of the foregoing, Sprint Spectrum shall at all times: 3.2.1 conduct the Permitted Activities so as to maintain legal and safe clearances from PSE's utility systems or improvements; 3.2.2 take all prudent precautions to ensure that no persons or property come into contact with PSE's utility systems or improvements; and 3.2.3 conduct the Permitted Activities so as to maintain access along and across the Site to PSE's utility systems and improvements, sufficient to allow the free passage of all equipment, vehicles, personnel and other items as may be necessary or convenient for the maintenance, repair and replacement of PSE's utility systems and improvements. If, at any time, the Permitted Activities shall disturb, interfere with or otherwise impair the safe, continuous and reliable operation of PSE's utility systems or improvements, Sprint Spectrum shall immediately cease and discontinue such Permitted Activities. If Sprint Spectrum anticipates that any Permitted Activity may disturb, interfere with or otherwise Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 2 impair the safe, continuous and reliable operation of PSE's utility systems or improvements, Sprint Spectrum shall request in writing, not less than fourteen (14) days in advance of the date required, that PSE take such action with respect to its systems or improvements as is necessary to accommodate such Permitted Activity. PSE may elect to accommodate such Permitted Activity in response to such request; provided, however: (a) all costs and expenses incurred by PSE thereby shall be reimbursed to PSE, and (b) PSE may refuse any or all such requests or may discontinue actions undertaken in response to such requests, as PSE, in its sole discretion, may choose. 3.3 Sprint Spectrum shall not undertake any activities and shall not use or permit any use of the Site that will in any way: 3.3.1 be in noncompliance with, or otherwise conflict with, any applicable laws, regulations, ordinances, rules, orders or other requirements, now or hereafter in effect, of any governmental authority (all laws, regulations and orders required to be incorporated in agreements of this character are hereby incorporated herein by this reference); 3.3.2 cause or constitute any nuisance, noxious odors, unsafe condition or waste in or about the Site; 3.3.3 interfere with the rights or disturb the use and enjoyment of PSE, other users of the Site, or any other person lawfully on the Site; 3.3.4 cause a cancellation, increase the premiums for or deductibles under or otherwise affect any fire, casualty, property, liability or other insurance covering the Site, any activities conducted upon or from the Site, or any accident, act, error, omission, fault, negligence or strict liability occurring on or about the Site; or 3.3.5 except as otherwise provided in the Site Development Plan, cause or allow the generation, storage, processing, handling, transport, spill, disposal or release of any dangerous, hazardous or extremely hazardous material, waste or substance at, upon or in any way affecting the Site (including, but not limited to, any such materials, waste or substances subject to regulation by any federal, state or local law pertaining to the protection of human health or the environment). 3.4 Sprint Spectrum shall not, and shall not permit others to, install, store, maintain or operate any equipment, fixtures, improvements, supplies, vehicles or other items on the Site except for the Equipment (which Equipment shall be installed, maintained and operated at Sprint Spectrum's sole cost, risk and expense). 3.5 Sprint Spectrum shall obtain and comply (and shall ensure that all of Sprint Spectrum's Support comply) with all permits, licenses, franchises, rights -of -way, easements and other rights required to undertake any Permitted Activity. Sprint Spectrum shall famish to PSE such evidence thereof as PSE may request. Sprint Spectrum SE63XC320 Marine View Substation —PSE (SEA]23) Page 3.6 I£ in PSE's reasonable judgment, the Equipment or any Permitted Activity violates, jeopardizes or unreasonably interferes with: (a) any laws, regulations, rules, orders or other regulatory authorizations, permits or approvals that may concern PSE's present or future use and enjoyment of the Site, or (b) any proprietary rights such as any contract, permit, license, franchise, right-of-way, easement or other rights of PSE, and Sprint Spectrum fails to correct the problem within thirty (30) days after written notice from PSE (or such shorter or (to the extent reasonably necessary to correct the problem) longer period of time as is expressly required or permitted under the applicable law, regulatory authorization, permit or approval or applicable proprietary right of PSE), PSE may require that Sprint Spectrum immediately remove any or all Equipment from and cease any Permitted Activity at the Site. If Sprint Spectrum fails to remove any Equipment within fifteen (15) days after PSE makes its request, PSE may remove the Equipment at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 3.7 Sprint Spectrum shall timely pay all (and shall promptly secure the discharge of any liens asserted by any) persons and entities furnishing labor, equipment, materials or other items in connection with the Permitted Activities. Sprint Spectrum shall furnish to PSE such releases of claims and other documents as may be requested by PSE from time to time to evidence such payment (and discharge). If any such persons or entities are not timely paid (or if any of such liens are not promptly discharged), PSE may make such payments (and secure such discharge) at Sprint Spectrum's expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. Sprint Spectrum may contest the validity of any such lien provided that Sprint Spectrum delivers a bond to PSE in the amount of the contested lien. 3.8 In undertaking the Permitted Activities, Sprint Spectrum shall comply and shall ensure that all of its Support comply with all applicable industry standards and codes, and all of PSE's standard practices, specifications, rules and regulations provided by PSE to Sprint Spectrum on request. Sprint Spectrum shall fumish such documents as may be required to effect or evidence such compliance. 3.9 Sprint Spectrum shall comply with the following in connection with its performance of the Work: 3.9.1 Sprint Spectrum shall fiu-nish all personnel, supervision, labor, transportation, tools, equipment and materials for performance of the Work. Sprint Spectrum shall expeditiously and efficiently perform the Work in accordance with the Site Development Plan and the provisions of this Permit. Sprint Spectrum shall not independently hire any PSE employee to perform any of the Work (e.g., other than in the course of his or her employment with PSE with respect to Work that PSE agrees to perform for Sprint Spectrumn). 3.9.2 Sprint Spectrum shall perform the Work in a workmanlike and skillful manner. Sprint Spectrum shall ensure that the Work and the Equipment is in all respects (a) safe, (b) of first-class quality, (c) free from all faults and defects in workmanship, material and design, and (d) in conformance with such reasonable Sprint Spectrum SE63XC320 Marine View Substation —PSE (SEA123) Page 4 requirements and specifications as PSE shall from time to time prescribe and all laws and the regulations, orders and decrees of all Iawfully constituted bodies and tribunals pertaining to the construction, operation and maintenance, including without limitation, the requirements of the latest edition of the National Electrical Safety Code. 3.9.3 Sprint Spectrum shall promptly and satisfactorily correct or replace any Work or Equipment found to be defective or not in conformity with the requirements of this Permit. If Sprint Spectrum fails or refuses to perform any Work required by this Permit or to make any such corrections or replacements, PSE may perform such Work and make such corrections and replacements at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 3.9.4 installation of the Equipment or the performance of other Work shall not adversely affect the structural integrity, maintenance or marketability of the Site or any structure or improvement on or surrounding the Site. 3.9.5 Sprint Spectrum shall ensure that all personnel who perform the Work shall be fully experienced and properly qualified to perforin the same. Sprint Spectrum shall, if so requested by PSE, remove from performance of the Work any personnel (including, without limitation, any Support) whom PSE finds to be incompetent, careless or otherwise unsafe. 3.9.6 Sprint Spectrum hereby acknowledges that PSE employs workers covered by one or more collective bargaining agreements. In the event of any actual or potential labor dispute between PSE and its workers that is, in whole or in part, based upon or otherwise arises out of the performance of the Work or this Permit, Sprint Spectrum will cooperate with PSE and take such action as may be reasonably requested by PSE to fully and expeditiously resolve such dispute. 3.9.7 Sprint Spectrum shall, at all times, keep the Site cleared of rubbish, refuse and other debris generated by Sprint Spectrum or its Support and in a neat, clean and safe condition. Upon completion of any portion of any of the Work, Sprint Spectrum shall promptly remove all rubbish, refuse and other debris generated by Sprint Spectrum or its Support and all of its Equipment and surplus materials. 3.9.8 The Work and the Equipment (i.e., as it relates to the Work) shall at all times be subject to inspection and testing by PSE. Sprint Spectrum may, at its option, have a representative present at the Site during any such inspection or testing by PSE. If, in PSE's reasonable judgment, the performance of any Work requires one or more representatives of PSE to be present at the Site during the performance of such Work, then Sprint Spectrum will reimburse PSE for any and all reasonable costs and expenses thereby incurred by PSE. No inspection, test, delay or failure to inspect or test, or failure to discover any defect or non-compliance by PSE shall relieve Sprint Spectrum of any of its obligations under this Permit. Sprint Spectrum SE63XC320 Marine View Substation— PSE (SEA123) Page 5 3.9.9 Sprint Spectrum shall promptly settle or resolve all complaints received by Sprint Spectrum from third Parties arising out of or in connection with performance of the Work. Sprint Spectrum shall promptly notify PSE of all such complaints and any action taken (or to be taken) in connection therewith. In handling any complaints, Sprint Spectrum shall use its best efforts to maintain and promote good public relations for PSE. 3.9.10 Sprint Spectrum acknowledges and anticipates that the Work may be interfered with and delayed from time to time on account of the concurrent performance of work by PSE or others. Sprint Spectrum shall fully cooperate with PSE and others and coordinate the Work with such other work so as to minimize any delay or hindrance of any work. 3.9.11 If any part of the Work depends upon the results of other work by PSE or others, Sprint Spectrum shall, prior to commencing such Work, notify PSE in writing of any actual or apparent deficiencies or defects in such other work that render it unsuitable for performance of the Work. Failure of Sprint Spectrum to so notify PSE shall constitute an acceptance by Sprint Spectrum of such other work as suitable for performance of the Work, except as to latent defects which may subsequently be discovered in such other work. 3.10 Upon completion of Permitted Activities which may disturb the surface or subsurface of the Site (or any improvements thereon), Sprint Spectrum shall restore the Site (and any improvements thereon) to a condition as good or better then the condition the Site (or such improvements) was in prior to such disturbance. 3.11 If, in undertaking Permitted Activities (or activities off -Site in furtherance of Permitted Activities), Sprint Spectrum shall cause significant public concern with or opposition to its proposed use of the Site, and PSE shall reasonably conclude that such public concern or opposition will materially interfere with its use of the Site or otherwise with the conduct of PSE's business, then PSE may direct Sprint Spectrum to cease and desist such acts (or omissions) giving rise to such public opposition or concern. 3.12 Sprint Spectrum shall copy PSE's T&D Planning & Analysis Department Director on all notices and other correspondence received or given by Sprint Spectrum in connection with any local jurisdiction review process involving any Permitted Activities undertaken or proposed to be undertaken by Sprint Spectrum at the Site. 4. Equipment, Structures and Facilities. 4.1 Sprint Spectrum shall maintain all Equipment on the Site in good and safe condition and in a manner that does not materially affect the structural integrity of any structure on the Site. If Sprint Spectrum fails to do any maintenance within thirty (30) days after receipt of notice from PSE requesting such maintenance, then PSE may, at its option, do such maintenance at Sprint Spectrum's expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. If Sprint Spectrum commences the requested Sprint Spectrum SE63XC320 Marine View Substation —PSE (SEA123) Pat, maintenance within thirty (30) days after any written notice from PSE requesting such maintenance and thereafter continuously and diligently pursues and completes such maintenance, then the thirty (30) day cure period will extend for an additional sixty (60) days to permit Sprint Spectrum to complete the requested maintenance. 4.2 PSE shall at all times during the Term of this Permit, at PSE's sole cost and expense, maintain any PSE-owned structures used by Sprint Spectrum for Permitted Activities in a structurally good and safe condition. If Sprint Spectrum is unable to use such structure due to PSE's maintenance activities, Sprint Spectrum may immediately install temporary Equipment on any alternate location specified in the Site Development Plan while PSE makes repairs to the Site. 4.3 If PSE at any time relocates, replaces or removes any pole, tower or other facility or structure on which any Equipment is attached, or PSE otherwise determines in its reasonable judgment that any Equipment must be removed or relocated to accommodate PSE's use of or activities on the Site, then Sprint Spectrum shall, at its sole cost and expense, remove or relocate such Equipment at such times and in the manner directed by PSE. If Sprint Spectrum fails to remove or relocate its Equipment within one hundred eighty (180) days (or such shorter period of time as PSE may reasonably require under the circumstances) after being directed to do so by PSE, PSE may remove or relocate the Equipment at Sprint Spectrum's sole risk and expense, and Sprint Spectrum shall reimburse PSE for the entire expenses thereby incurred. 4.4 In the event Sprint Spectrum is permitted to and does install any pole, tower or other structure as part of the Equipment on the Site, PSE shall have the right, subject to such reasonable rules and requirements as the parties may agree upon in writing, to install one or more items of equipment on such pole, tower or other structure for PSE's internal purposes only, provided that the pole, tower or structure in question is structurally capable of bearing the weight of PSE's equipment. Such installation and use shall be at PSE's cost and expense, but Sprint Spectrum shall not levy any charge or fee for PSE's use thereof. 5. Nonexclusivi. This Permit is nonexclusive, and PSE may grant rights to others to use the Site for any purpose not inconsistent with Sprint Spectrum's rights hereunder. PSE does not warrant title to the Site and shall not be liable for defects thereto or failure thereof. Without limiting any other provision of this Permit, Sprint Spectrum will promptly resolve technical interference problems with other radio communications equipment located at the Site on the date of this Permit or any radio communications equipment located at the Site on any future date when Sprint Spectrum modifies or supplements its Equipment at the Site. Likewise, PSE will not permit the installation of any future radio communications equipment which results in technical interference problems with Sprint Spectrum's then -existing Equipment at the Site; provided that the foregoing obligation of PSE shall only apply if and to the extent PSE is expressly entitled by contract or applicable law to prevent or refuse to permit such installation. 6. Cooperation of PSE. PSE shall, at Sprint Spectrum's expense, support Sprint Spectrum's efforts to secure any documents or applications required (i.e., by virtue of Sprint Spectrum SE63XC320 Marine View Substation— PSE (SEA123) Page 7 PSE's ownership of or rights in the Site) to be obtained by Sprint Spectrum from any governmental agency with jurisdiction in order for Sprint Spectrum to obtain the necessary licenses, permits or other approvals from such governmental agency for the Permitted Activities; provided, however, that PSE shall not under any circumstances be obligated to execute any application or other document that, in PSE's sole judgment, will in any way impair, limit or adversely affect PSE's rights in or ownership or use of the Site, nor shall PSE be obligated to provide such support if the same requires a commitment of resources of any kind of a value in excess of 7. Emergencies. In the event of an emergency relating to the Equipment or the Site, Sprint Spectrum shall immediately correct any safety or use problems, even if full repair cannot be made at the time, in order to protect persons and property or to allow use of the Site. The Parties' respective emergency phone numbers are as follows: PSE:=NLEM Sprint Spectrum: Each Party shall promptly notify the other of any change in such party's emergency phone number. 8. Ownership and Risk of Loss of E-cluiment. 8.1 The Equipment located at the Site pursuant to the terms of this Permit will at all times be and remain the property of Sprint Spectrum and will not be subject to any lien or encumbrance created or suffered by PSE. Sprint Spectrum has the right to make such filings with the Washington State Department of Licensing (e.g., UCC-1 Financing Statement) as it deems necessary or desirable to evidence its ownership of the Equipment. Notwithstanding the foregoing, if, upon termination or expiration of the Term, the Equipment is not removed from the Site and the Site restored according to the terms of this Permit, such Equipment shall be deemed abandoned thirty (30) days following such termination or expiration and PSE's waiver of lien shall thereafter be void and of no further force and effect. 8.2 Sprint Spectrum shall be responsible for and shall bear any and all risk of loss, deterioration, theft, vandalism or destruction of or damage to the Equipment and anything used (or to be used or consumed) in connection with the Work. 9. Examination of Records. Sprint Spectrum shall promptly furnish PSE with such information related to the Work or the Equipment as may from time to time be reasonably requested by PSE. Until the expiration of three (3) years after the termination of the Term, PSE shall have access to and the right to examine and copy all of Sprint Spectrum's books, documents, papers and records which are related to the Work, the Equipment or this Permit. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 8 10. Compensation. 10.1 The "Annual Fee" shall mean the annual fee for Sprint Spectrum's use of the Site as calculated in accordance with the schedule set forth in the attached Appendix 4 and the following: 10.1.1 The Annual Fee will be payable on or before the date of this Permit and thereafter on the first day of the first month following each anniversary of the commencement date of the Master Agreement, and 10.1.2 The Annual Fee will be prorated in the first and last year of this Permit to coincide with the anniversary of the commencement date of the Master Agreement. If Sprint continues to hold any Site after the termination of the applicable Permit, whether the termination occurs by lapse of time or otherwise, such holding over will, unless otherwise agreed to by PSE in writing, constitute and be construed as a month -to -month tenancy at a monthly Fee equal to of the Annual Fee for such Permit until all of the Equipment is removed from the Site and restoration of the Site has occurred according to the provisions of this permit, and will remain subject to all of the other terms set forth in this Agreement. 10.2 PSE shall invoice Sprint Spectrum for all amounts payable by Sprint Spectrum to PSE under this Permit (including, without limitation, the Annual Fees and all reimbursable costs and expenses described elsewhere in this Permit) as they become due. Sprint Spectrum shall pay each such invoice in full within thirty (30) days after Sprint Spectrum's receipt thereof 10.3 Sprint Spectrum acknowledges that late payment of any fee or other amounts due to PSE under this Permit will cause PSE to incur certain administrative, processing accounting costs not otherwise contemplated by this Permit, the exact amount of which will be extremely difficult, if not impossible, to ascertain. Accordingly, if any fee or other amounts shall not be received by PSE within thirty (30) days after such amounts shall first become due, Sprint Spectrum shall pay to PSE a late charge, as liquidated damages and not as a penalty, equal to of such overdue amounts as a reasonable estimate of the administrative, processing and accounting costs PSE will incur by reason of late payment by Sprint Spectrum. Such late charge is intended to be in lieu of Sprint Spectrum's liability for such costs, but shall not relieve or release Sprint Spectrum from liability for any other costs or damages suffered by PSE by reason of late payment. Payment of such late charge shall in no event excuse or cure any default under or breach of this Permit by Sprint Spectrum. 10.4 In addition to any late charge levied under this Permit, Sprint Spectrum shall pay to PSE interest, compounded daily, at the rate o per month or the maximum rate permitted by applicable law, whichever is less, on any fees or other amounts not paid to PSE when due under this Permit, from the date due until the date paid. Payment Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 9 of such interest shall not excuse or cure any breach of or default under this Permit by Sprint Spectrum. 11. Taxes. Sprint Spectrum shall pay (except as otherwise required by law) all fees and taxes applicable to or incurred in connection with the Work, the Equipment or the system of which the Equipment constitutes a part. Subject to the foregoing, PSE shall pay all taxes and other fees or charges attributable to each Site (including, without limitation, debt and ground Iease obligations). 12. Site Acce tance. 12.1 Sprint Spectrum will be deemed to have accepted the Site upon execution of this Site Permit. Conducting feasibility and cost assessments or other preliminary inspections on the Site prior to execution of this Site Permit shall not be deemed to be acceptance. 12.2 Acceptance of the Site by Sprint Spectrum in accordance with paragraph 12.1 shall be conclusive evidence that Sprint Spectrum: 12.2.1 accepts the Site as suitable for the Permitted Activities; 12.2.2 accepts the Site and any structure on the Site and every part and appurtenance thereof "AS IS," "WHERE IS" and "WITH ALL FAULTS AND DEFECTS"; and 12.2.3 releases, and waives all claims against, PSE in respect of defects in the Site and its structures and appurtenances, their habitability or suitability for any permitted purposes, except as expressly provided otherwise in this Agreement. 12.3 PSE does not warrant the suitability of the Site for the purposes for which Sprint Spectrum may desire to use it (including, without limitation, the Permitted Activities); nor does PSE warrant the adequacy of the Site's location, its condition nor the condition of any structure or appurtenances for any purpose. Sprint Spectrum acknowledges that, in accepting the Site (and any and all structures thereon used by Sprint Spectrum for Permitted Activities) in its "AS IS," "WHERE IS" and "WITH ALL FAULTS AND DEFECTS" condition, PSE makes no representations or warranties whatsoever concerning the Site and/or such structures, or any aspect of their status or condition, and that Sprint Spectrum is not in any way relying on information disclosed by PSE with respect thereto, or otherwise in PSE's possession with respect thereto; rather, Sprint Spectrum is solely relying on its own inspections and assessments with respect to the condition or status of the Site and/or such structures. 13. Term and Termination. 13.1 The term of this Permit (the "Term") will commence on the date of this Permit and, unless earlier terminated as provided elsewhere in this Permit, will end upon expiration of the term of the Master Agreement. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 10 to occur: 13.2 The Term will terminate automatically upon the first of the following 13.2.1 the term of the Master Agreement at any time expires or is terminated for any reason; 13.2.2 any certificate, permit, license or approval affecting Sprint Spectrum's ability to use the Site in the manner originally intended by Sprint Spectrum is finally rejected or not likely to be obtained; or 13.2.3 any previously issued certificate, permit, license or approval affecting Sprint Spectrum's ability to use the Site is canceled, expires, lapses, or is otherwise withdrawn or terminated by the applicable governmental agency. 13.3 PSE may at any time terminate the Tenn and all of Sprint Spectrum's rights to use the Site upon: 13.3.1 sixty (60) days' prior written notice to Sprint Spectrum if any Permitted Activity unreasonably interferes with (a) PSE's or any other prior existing user's use of the Site, or (b) access to or around the Site or any structure adjacent to the Site by PSE or any other prior existing users of PSE's property on or adjacent to the Site and Sprint Spectrum fails to cure such interference to PSE's reasonable satisfaction within such sixty (60) day period, or 13.3.2 the occurrence of any Event of Default. 13.4 Sprint Spectrum may terminate the Term upon thirty (30) days' prior written notice to PSE if Sprint Spectrum is unable (e.g., for technological reasons) to use the Site for the Permitted Activities or, due to significant opposition by any third party, it appears unlikely that zoning can be obtained for the Site in a timely fashion; provided, however, that Sprint Spectrum shall use reasonable efforts to obtain such zoning and/or resolve such opposition. 14. Default. 14.1 The occurrence of any one or more of the following events constitutes an "Event of Default" by Sprint Spectrum under this Permit: 14.1.1 Sprint Spectrum undertakes any activities on the Site other than the Permitted Activities; 14.1.2 Sprint Spectrum fails to pay when due the full amount of any fee or other payment under this Permit, where such failure continues for fifteen (15) days after written notice thereof by PSE to Sprint Spectrum; 14.1.3 Sprint Spectrum fails to cure any other default under or breach of any provision of this Permit (i.e., other than a default or breach covered by Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 11 paragraph 11.1.1) within thirty (30) days after PSE gives Sprint Spectrum written notice of such default or breach; except such thirty (30) day cure period will be extended as reasonably necessary to permit Sprint Spectrum to complete cure so long as Sprint Spectrum commences cure within the thirty (30) day cure period and thereafter continuously and diligently pursues and completes such cure; 14.1.4 two (2) or more defaults by Sprint Spectrum in the payment of any fee or other payments under the Permit which would allow PSE to issue a notice of default in any twelve (12) month period, which such occurrence will constitute a noncurable material default and breach of this Permit; 14.1.5 Sprint Spectrum deserts, abandons, or vacates any portion of a Site and fails to maintain any and all Equipment remaining at the Site. 14.2 If an Event of Default occurs, PSE (without notice or demand except as expressly required above) may, in addition to any other right or remedy to which PSE may be entitled under this Permit or applicable law, recover from Sprint Spectrum an amount equal to the sum of the following: 14.2.1 the actual costs of removing the Equipment and restoring the Site to its original condition; 14.2.2 the Annual Fees for the Site until such time as the Site is restored to its original condition, plus interest thereon from the date due until paid according to the terms of this Permit; 14.2.3 the amount by which the Annual Fees and other benefits that PSE would have received under this Permit for the remainder of the Term after the date of termination exceeds the amount of the fair market rental value for the remainder of the Term that Sprint Spectrum proves could be reasonably avoided, discounted at the discount rate on the date of termination of the Federal Reserve Bank of the federal reserve district where the Site is located plus one percent and 14.2.4 all other suns of money and damages to which PSE may be entitled hereunder or under applicable law. 15. )Effect -of Termination. Within thirty (30) days after termination of the Tenn, Sprint Spectrum shall remove all Equipment from the Site and restore the Site to its original condition except for reasonable use, wear and tear. Sprint Spectrum will repair any damage to the Site caused during the removal of the Equipment. Following expiration of the above thirty (30) day period, PSE shall furnish to Sprint Spectrum a Iist of any removal, restoration, repair or other work that remains to be completed at the Site. Sprint Spectrum will thereafter complete the work specified on the list within ten (10) days after receipt of the list from PSE. If Sprint Spectrum shall fail to complete the specified work within the ten (10) day period, PSE may complete the work, or have the work completed through the most expeditious Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA i 23) Page 12 means available, at Sprint Spectrum's sole risk and expense and Sprint Spectrum shall reimburse PSE for the entire expense thereby incurred. 16. Release. Indemnity Hold Harmless and Limitation of Liability. 16.1 Sprint Spectrum releases and shall defend, indemnify and hold harmless the Indemnitees from any and all claims, losses, costs, liabilities, damages and expenses (including, but not limited to, reasonable attorneys' fees) arising (whether before or after termination of the Tenn) out of or in connection with the conduct of the Permitted Activities (including, without limitation, the location of any Equipment at the Site, the performance of the Work, or the operation of the Equipment or the system of which the Equipment is a part), the enforcement of this Permit by PSE, any default under or breach of this Permit by Sprint Spectrum or the acts or omissions of Sprint Spectrum or any of its Support, the respective successors and assigns of Sprint Spectrum or any of its Support, the directors, officers, employees and agents of each of the foregoing, or anyone acting on Sprint Spectrum's behalf in connection with this Permit. To the fullest extent permitted by applicable law, the foregoing release, indemnity and hold harmless shall apply regardless of any act, omission, fault, negligence or strict liability of the Indemnitees; provided, however, that Sprint Spectrum shall not be required to so indemnify any Indemnitee(s) against any claim, loss, cost, liability, damage or expense to the extent the same is caused by or results from the negligence or willful misconduct of any Indemnitee(s). In connection with any action to enforce this paragraph 17.1, Sprint Spectrum waives any immunity, defense, or protection under any workers' compensation, industrial insurance or similar laws (including, but not limited to, the Washington Industrial Insurance Act, Title 51, of the Revised Code of Washington). PSE is willing to permit the Equipment on the Site for the fees described in this Pen -nit only in consideration of and in reliance upon such release, indemnity and hold harmless. Consequently, such release, indemnity and hold harmless shall be construed broadly in favor of the Indemnitees. 16.2 NOTWITHSTANDING ANY OTHER PROVISION OF THIS PERMIT, PSE SHALL NOT HAVE ANY LIABILITY TO SPRINT SPECTRUM FOR ANY: LOSS OF PROFIT OR REVENUE, LOSS OF USE OF THE EQUIPMENT OR THE SYSTEM, CLAIMS OF CUSTOMERS OF SPRINT SPECTRUM FOR SERVICE INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL, ECONOMIC OR CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR OTHERWISE, EVEN IF PSE HAS BEEN ADVISED OF THE POSSIBILITY OF THE SAME. 16.3 NOTWITHSTANDING ANY OTHER PROVISION OF THIS PERMIT, SPRINT SPECTRUM SHALL NOT HAVE ANY LIABILITY TO PSE FOR ANY LOSS OF PROFIT OR REVENUE, CLAIMS OF CUSTOMERS OF PSE FOR SERVICE INTERRUPTIONS, OR INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, AS A RESULT OF OR RELATED TO THE Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 13 EQUIPMENT, THE EXISTENCE OF THE EQUIPMENT AT THE SITE, OR THIS PERMIT, WHETHER ARISING IN CONTRACT, TORT (INCLUDING, WITHOUT LIMITATION, NEGLIGENCE, PRODUCT LIABILITY OR STRICT LIABILITY) OR OTHERWISE, EVEN IF SPRINT SPECTRUM HAS BEEN ADVISED OF THE POSSIBILITY OF THE SAME. 16.4 PSE'S LIABILITY (WHETHER IN TORT, CONTRACT OR OTHERWISE AND NOTWITHSTANDING ANY FAULT, NEGLIGENCE (WHETHER ACTIVE, PASSIVE OR IMPUTED), PRODUCT LIABILITY OR STRICT LIABILITY OF PSE) UNDER THIS PERMIT OR WITH REGARD TO THE SITE SHALL IN NO EVENT EXCEED THE COMPENSATION ACTUALLY PAID TO PSE UNDER THIS PERMIT WITH RESPECT TO THE SITE. 17. Worker's Compensation, Insurance and Bonds. 17.1 Sprint Spectrum shall ensure that Sprint Spectrum and all persons undertaking any Permitted Activities, including without limitation Sprint Spectrum's Support, maintain in effect at all times, coverage or insurance in accordance with the applicable laws relating to worker's compensation and employer's liability insurance (including, but not limited to, the Washington Industrial Insurance Act and the laws of the state in which any such person was hired), regardless of whether such coverage or insurance is mandatory or merely elective under the law. Sprint Spectrum shall furnish to PSE such assurance and evidence of such coverage or insurance (such as copies of insurance policies and Certificates of Compliance issued by the Washington State Department of Labor and Industries) as PSE may request. 17.2 Sprint Spectrum shall secure and maintain in effect at all times during the Tenn the following insurance: 17.2.1 fire insurance, with endorsements for extended coverage vandalism, and malicious mischief, on the Site, in an amount not less than ninety percent (90%) of the full replacement cost of the Site (including, without limitation, all equipment and facilities located thereon); and 17.2.2 Commercial General Liability Coverage, including personal injury, bodily injury, property damage, operations hazard, independent contractor coverage, contractual liability, products and completed operations liability and stop gap coverage, in limits not less than five million dollars ($5,000,000) for each occurrence (combined single limit) with Sprint Spectrum named as insured therein and PSE named as an additional insured therein as their respective interests may appear. 17.3 All required insurance policies must be taken out with reputable national insurers that are licensed to do business in the jurisdiction where the Site is located. Sprint Spectrum will deliver to PSE a Certificate of Insurance in the form attached to this Permit as Appendix 5 prior to commencement of performance of any of the Work. All Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 14 policies must contain an undertaking by the insurers to notify PSE in writing not less than fifteen (15) days before any material change, reduction in coverage, cancellation or termination of the insurance. Sprint Spectrum and PSE will each year review the limits for the insurance policies required by this Permit. Policy limits will be adjusted to proper and reasonable limits as circumstances warrant, but policy limits will not be reduced below those stated in paragraph 17.2 and no increases in the policy limits will be effective unless Sprint Spectrum and PSE mutually agree. 17.4 Sprint Spectrum shall also furnish PSE with such additional assurance and evidence of such insurance (such as copies of all insurance policies) as PSE may from time to time request. Within thirty (30) days after any notice of termination, cancellation, expiration or alteration in any policy of insurance required under this Permit, Sprint Spectrum shall deliver to PSE a Certificate of Insurance acceptable to PSE with respect to any replacement policy. 17.5 Sprint Spectrum shall ensure that any policies of insurance that Sprint Spectrum or any of its Support carry as insurance against: property damage or against liability for personal injury (including death) or property damage shall include a provision therein providing a waiver of the insurer's right to subrogation against the Indemnitees. To the extent pennitted by its insurance policies, Sprint Spectrum hereby waive all rights of subrogation against the Indemnities. 17.6 All insurance carried by Sprint Spectrum or any of its Support shall be primary insurance with respect to the interests of PSE, and any insurance or self-insurance maintained by PSE is in excess and not contributory insurance with the insurance required hereunder. 17.7 The requirements of this Permit as to insurance and acceptability to PSE of insurers and insurance to be maintained by Sprint Spectrum are not intended to and shall not in any manner limit or qualify the liabilities and obligations of or assumed by Sprint Spectrum under this Permit. 18. Assi nment Successors and Assicns. 18.1 Sprint Spectrum shall not assign this Permit or any portion of its rights in this Permit, except as follows: 18.1.1 to any person or entity that controls, is controlled by or under common control with Sprint Spectrum (the "Acquiring Affiliate"); provided that Sprint Spectrum gives PSE written notice of any such assignment or transfer and pays all amounts then outstanding and owing to PSE under this Permit; provided further that the Acquiring Affiliate certifies to PSE in writing (and provides such documents as may be requested by PSE to establish) that the Acquiring Affiliate (i) will assume all of the obligations of Sprint Spectrum under this Permit, and (ii) and will comply with all of the provisions of this Permit; and provided further that Sprint Spectrum Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA 123) Page 15 furnishes to PSE such information regarding the Equipment affected by such assignment or transfer as may reasonably be requested by PSE; 18.1.2 to Sprint Spectrum's lender(s) for security purposes in connection with the financing and refinancing, from time to time, by Sprint Spectrum, provided that upon any transfer pursuant to any foreclosure of such security or any sale or other transfer in lieu of such foreclosure the person or entity acquiring the interests subject to such transfer assumes all of the obligations of Sprint Spectrum under this Permit; or 18.2 Except as specifically provided in paragraph 18.1, any assignment or apportionment, or purported assignment or apportionment of this Permit, whether it be express, by operation of law or otherwise, shall be voidable by PSE. In any event, no assignment or apportionment of this Permit shall relieve Sprint Spectrum from any of its liabilities or obligations under this Permit. If at any time the aggregate net worth of Sprint Spectrum and any Acquiring Affiliates bound by this Permit is less than seventy-five million dollars ($75,000,000), or Sprint Spectrum fails to furnish PSE evidence of such aggregate net worth as PSE may reasonably request, then PSE will be entitled to immediately terminate the Term upon written notice of such termination to Sprint Spectrum. Subject to the foregoing restrictions on assignments without the prior written consent of PSE, this Permit shall be fully binding upon, inure to the benefit of and be enforceable by the successors and assigns of the respective Parties hereto. 19. Casualty or Condemnation of the Site 19.1 If there is a casualty to any structure upon which the Equipment is located, PSE will use reasonable efforts to repair or restore the structure within sixty (60) days. Upon completion of such repair or restoration, Sprint Spectrum will be entitled to reinstall the Equipment. In the event such repairs or restoration will, in PSE's reasonable estimation, require more than sixty (60) days to complete: 19.1.1 Sprint Spectrum or PSE will be entitled to terminate the Tenn; or 19.1.2 unless the Term is terminated as provided in paragraph 19.1.1, Sprint Spectrum may immediately install temporary Equipment, including any necessary supporting structure, (a) at the Site, or (b) at another unused portion of PSE's property adjacent to the Site, to the extent Sprint Spectrum has the rights to do so, while PSE makes repairs to the Site and so long as the temporary Equipment and associated Work does not interfere with PSE's own restoration and operation of its facilities. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA] 23) Page 16 19.2 If there is a condemnation of the Site, including without limitation a transfer of the Site by consensual deed in lieu of condemnation, then the Term will terminate upon transfer of title to the condemning authority, without further liability to either Party under this Permit. Sprint Spectrum may pursue a separate condemnation award for the Equipment and any relocation or other costs from the condemning authority provided that such award does not reduce the amount of PSE's award. 20. Subordination. 20.1 Sprint Spectrum agrees that this Permit is subject and subordinate at all times to the lien of all mortgages and deeds of trust securing any amount or amounts whatsoever which may now exist or hereafter be placed on or against the Site or on or against PSE's interest or estate therein, and any underlying ground lease or master lease on a particular Site, all without the necessity of having further instruments executed by Sprint Spectrum to effect such subordination. 20.2 This Permit is further subject to any and all restrictions or other terms or conditions contained in the underlying ground lease, master lease, easement, license, franchise, permit or other instrument of authorization or conveyance (an "Instrument") with respect to the Site_ Sprint Spectrum agrees to commit no act or omission which would constitute a violation of the terms and conditions of any Instn3 ment for the Site insofar as PSE has provided a copy of such Instrument to Sprint Spectrum or otherwise notified Sprint Spectrum of the term or condition in question. 20.3 PSE shall not be required to obtain any consent required under any Instrument from the landlord or other party to such Instrument for purposes of this Permit, unless hereafter agreed upon by PSE in writing. 20.4 If a restriction contained in an Instrument for the Site prevents Sprint Spectrum from installing, maintaining or operating the Equipment or accessing the Site, Sprint Spectrum will be entitled to terminate the Term. 20.5 Upon the termination or expiration of any Instrument with respect to the Site, the Terra shall automatically terminate without liability to either Party. Sprint Spectrum acknowledges that many of PSE's underlying Instruments grant to the property owner the right to terminate such Instruments, and that in the event of such termination, the Term shall terminate concurrently therewith without liability to either Party. 20.6 Upon any sale or other transfer of all or any portion of the Site, the Term will automatically terminate except to the extent the purchaser or transferee and Sprint Spectrum enter into an agreement for Sprint Spectrum's continued use of the Site and release PSE from any further obligation or liability with respect to the Site. PSE shall have no obligation to request or obtain such agreement from the purchaser or transferee. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA f 23) Page 17 20.7 PSE will not materially breach the terms or conditions of any Instrument with respect to a particular Site in a manner that causes Sprint Spectrum to lose its use of the Site. 21. Notices. Any notice, request, approval, consent, instruction, direction or other communication given by either PSE or Sprint Spectrum to the other under this Pen -nit shall be in writing and shall be delivered in person or mailed, properly addressed and stamped with the required postage, to: if to PSE: Puget Sound Energy, Inc. P.O. Box 90868 GEN-02E Bellevue, WA 98009-0868 Attn: Communications Siting and Services Department if to Sprint Sveetrurn: Sprint National Lease Management Sprint Law Department 6391 Sprint Parkway 6391 Sprint Parkway Mailstop KSOPHT0101-Z2650 Mailstop KSOPHT0101-Z2650 Overland Park, KS 66251-2650 Overland Park, KS 66251-2650 Attn: Real Estate Attorney Either Party may from time to time change such address by giving the other Party notice of such change in accordance with the provisions of this paragraph 21. 22. No Partnership. This Permit shall not be interpreted or construed to create an association, joint venture or partnership between the Parties or to impose any partnership obligations or liability upon either Party. Neither Party shall have any right, power or authority to enter into any agreement or undertaking for or on behalf of, to act as or be an agent or representative of, or to otherwise bind the other Party. 23. Attornevs' Fees. The prevailing Party in any suit, action, or arbitration filed or held concerning this Permit shall be entitled to recover, in addition to all other relief, its reasonable attorneys fees incurred in connection therewith, both at trial and on any appeal. 24. Severability. The invalidity or unenforceability of any provision of this Permit shall not affect the other provisions hereof, and this Permit shall be construed in all respects as if such invalid or unenforceable provisions were omitted. 25. Survival. All provisions of this Permit which may reasonably be interpreted or construed as surviving the completion, termination or cancellation of the Term or this Permit, shall survive the completion, termination or cancellation of the Term or this Permit. 26. Hem. The headings of sections and paragraphs of this Permit are for convenience of reference only and are not intended to restrict, affect or be of any weight in the interpretation or construction of the provisions of such sections or paragraphs. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 18 27. Nonwaiver. The failure of either Party to insist upon or enforce strict performance by the other Party of any of the provisions of this Permit, or to exercise any rights under this Permit, shall not be construed as a waiver or relinquishment to any extent of its right to assert or rely upon any such provisions or rights in that or any other instance; rather, the same shall be and remain in full force and effect. 28. Force Maieure. If a Party is delayed or hindered in, or prevented from performance required under this Permit (other than any delay or failure relating to payment of money, including, without limitation, the Annual Fees and all reimbursable costs and expenses described elsewhere in this Permit) by reason of earthquake, landslide, strike, lockout, labor trouble, failure of power, riot, insurrection, war, acts of God or other reason of like nature not the fault of the such Party, such Party is excused from such performance for the period of delay. The period for the performance of any such act shall then be extended for the period of such delay. 29. Memorandum of Use. Neither Party shall record this Permit or otherwise cause this Permit to be recorded. However, upon the request of either Party, the Parties shall execute, acknowledge, deliver and record a memorandum of use in form and content substantially the same as the attached Appendix 6. Upon termination of the Tenn for any reason, the Parties shall execute, acknowledge, deliver and record a termination document in form and content acceptable to PSE. 30. Entire Agreement. The rights and obligations of the Parties hereunder shall be subject to and governed by this Permit. This Permit sets forth the entire agreement of the Parties, and supersedes any and all prior agreements, with respect to the Equipment, the Work, the Site and other subject matter of this Permit. This Permit may not be modified except by a writing executed contemporaneously herewith or subsequent hereto signed by both Parties. 31. Applicable Law. This Permit shall in all respects be interpreted, construed and enforced in accordance with the laws of the State of Washington. 32. Conditional Approval. 32.1 Sprint Spectrum shall provide complete detailed final jurisdictionally approved construction drawings before construction begins for PSE's review and approval. Said drawings shall show in detail the following, if applicable: 32.1.1 Grounding design of equipment and fencing in accordance with the National Electrical Safety Code provisions in Section 9, and PSE's internal design policies. Location of the telephone cable installation from source to the equipment cabinets. 32.1.2 Field verification of location of property lines establishing that proposed equipment shelter and pole location lies as noted, Sprint Spectrum SE63XC320 Marine View Substation —PSE (SEA123) Page 19 32.1.3 Landscape design showing acceptable vegetation compatible with electrical facilities and or substations. 32.2 Any comments and conditions noted during PSE's review process. 32.3 This is an existing Qwest Wireless site #SEA123. Sprint Spectrum's installation at the site will consist of utilizing a portion of Qwest Wireless's existing antennas and coax on the monopole located on the Substation property. Sprint Spectrum's BTS cabinets will also be located in the existing cabinet area. 32.4 A list of materials and equipment provided to PSE in advance of construction for PSE's review. Upon arrival, materials will be delivered to the site of a mutually acceptable location and accepted by PSE before construction commences. 32.5 No construction shall commence prior to the receipt and written approval by PSE of the final construction drawings and evidence of authorization by all governmental agencies having jurisdiction over the project. An on site pre -construction meeting shall be scheduled prior to construction and as -built drawings shall be provided after completion of construction. 32.6 If any landscaping is part of the wireless facilities at this site it must be approved by PSE, and it will be Sprint Spectrum's responsibility to maintain the installed landscaping and meet the terms and conditions of the landscape plan. If the installed Iandscaping is not maintained to jurisdictional and/or PSE standards, then PSE may, at its option but not an obligation, perform these maintenance activities at Sprint Spectrum's cost and expense. Sprint Spectrum agrees to reimburse PSE for these costs within thirty (30) days from the date of the statement. 32.7 Sprint Spectrum will provide wireless facility specifications and design, and will procure and install their wireless system with all costs being paid by Sprint Spectrum as provided for herein. PSE will determine the area available, if any, for Sprint's use. In the event PSE decides that the space required by Sprint can not be provided, PSE may withhold site approval. Sprint Spectrum SE63XC320 Marine View Substation — PSE (SEA123) Page 20 Sprint: Sprint Spectrum L.P. By; r -0 f SPR 6T SPECTRUM L.F. PETER MUNSEPt Its: 31TE DEVELOPMENT 149F1KMER (Title) / Date Signed: • •ri! ..l.�s PSE: Puget Sound Energy, Inc. By: Z6 "4- -,-'Z"Howard Strong Its: Manager Real Estate Date Signed: r' 2 -04- On this - 12� day of 2004, before me, a Notary Public in nd far the State of C du[ coinmissioned and sworn, pers ally appeared 1--�-N o me known to be the c�� e !,_ Sprint Spectrum that ix6uted the foregoing instrument and acknowledged the same to be the free and voluntary act and deed of said municipal corporation, for the uses and purposes therein mentioned, and on oath stated that he is authorized to execute the said instrument. Witness my hand and official seal hereto affixed toe qay and year in this certificate above written. USA U. f(4' A' Print Marra - Comm"'n N 1303787 Notary Pub is in and or the State of @MVNotZPuXb1' 1GnloResiding at med°Co"a�M commission ex Tres Comm.EOjes May 7. 2005 5' p Sprint Spectrum SE63XC320 Marine View Substation -PSE (SEA]23) Page 21 � RECEIVED SEP 2 9 2017 Sprint Site Modification to Facility SE63XC320 GOIMyC)RY ODVP PMEHT Project Narrative: Sprint intends to modify an existing site location at 1741 S 356th Street, Federal Way, WA 98003. The proposal consists of the removal of (6) antennas and the installation of (3) antennas, (6) RRUs, (3) filters, (1) hybrid cable and (1) collar mount. CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT DEPARTMENT DEVELOPMENT REVIEW COMMITTEE TRANSMITTAL DATE: 10/12/2017 TO: Cole Elliott, Development Services Manager Peter Lawrence, Plans Examiner Brian Asbury, Lakehaven Water & Sewer District Chris Cahan, South King Fire & Rescue FROM: Dave Van De Weghe, Senior Planner FOR DRC MTG. ON: 10/26/2017 - Internal FILE NUMBER(s): 17-104663-00-UP RELATED FILE NOS.: None PROJECT NAME: Jeffries Antenna Modification PROJECT ADDRESS: 29205 18TH AVE S ZONING DISTRICT: BC PROJECT DESCRIPTION: Removal of (6) antennas and installation of (3) antennas, (6) RRUs, (3) filters, (1) hybrid cable and (1) collar mount. LAND USE PERMITS: Use Process I PROJECT CONTACT: Natalia Jepsen, njepsen@md7.com MATERIALS SUBMITTED: Site plan set OF 40'::tt9:P Federal Way 41k RECEIVE MASTER LAND USE APPLICATION DEPARTMENT OF CommuNiTY DEVELOPMENT �EP �a17 Federal 8`" Avenue South Way, WA 98003-6325 253-835-2607;Fax 253-835-2609 CITY OF FEDERAL WAY www.cit ❑ffederaiwa .corn COMMUNITY DEVELOPMENT APPLICATION NO(s) / -7 — Ito Y6 3 I U �O Date / " 42 �— Project Name Jefferies Property Address/Location 29208 18th Avenue South, Federal Way, WA 98003 3040200065 Parcel Number(s) Project Description Remove (6) antennas. Install (3) antennas, (6) RRUs , (3) filters, (1) hybrid cable and (1) collar mount. PI.F.ASF. PRINT Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information CE Zoning Designation Comprehensive Plan Designation Value of Existing Improvements Value of Proposed Improvements International Building Code (IBC): Occupancy Type Construction Type Applicant Name: Sprint Address: 6580 Sprint Parkway City/State: Overland Park, KS Zip: 66211 Phone: Fax: Email: Signature: Agent (if different than Applicant) Name: Natalia Jepsen Address:10590 West Ocean Air Drive, Suite 300 City/State: San Diego, CA Zip: 92130 Phone: 858-964-7430 Fax: Email: njepsen@md7.com Signature;—X--� .A Owner Name: Sprint Address: PO Box 876783 City/State: Kansas City, MO Zip: 64187 Phone: Fax: Email: Signature: 4 Bulletin 403 — January 1, 2011 Page 1 of 1 k:\HandoutsWlaster Land Use Application IL Sprint April 7, 2017 RE: Md7, LLC as representative for Sprint To Whom It May Concern: Md7, LLC and its employees are authorized representatives of Sprint and have been contracted to perform cellular site development (i.e. real estate leasing, land use entitlements, materials procurement, architectural engineering, equipment installation, design, and construction, etc.) on behalf of Sprint, in connection with their telecommunications facility. As an authorized representative of Sprint, Md7, LLC may submit/order (i.e. land use applications and permits, utilities, real estate leasing, etc.) on behalf of Sprint. Sincerely, Kevin Foy (206)-427-5856 Sprint Network Real Estate ge Emelope ID: 819FC2D9-073H948-9129-3359CB SaE8 &M Sprint' SPRINT SITE NUMBER: SE63XC320 SPRINT SITE NAME: JEFFRIES SITE TYPE: MONOPOLE TOWER HEIGHT: 851-011 SITE INFORMATION SITE NAME: SEATTLE QWEST - SEA123 SITE ADDRESS: 29208 -18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 COUNTY- KING MAP/PARCEL #: 3040200065 AREA OF CONSTRUCTION: EXISTING LATITUDE: 47e 20' 21.74" LONGITUDE: -122a 18' 42.6" LAT/LONG TYPE: NAD83 GROUND ELEVATION: 449.0 FT. CURRENT ZONING: NOT AVALIABLE JURISDICTION: CITY OF FEDERAL WAY OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: VB A.D.& COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: SPRINT PO BOX 876783 KANSAS CITY, MO 64187-6783 TOWER OWNER GLOBAL SIGNAL ACQUISITIONS II LLC 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CARRIER/APPLICANT: SPRINT 10590 W OCEAN AIR DR, STE 300 SAN DIEGO, CA 92130 CROWN CASTLE APPLICATION ID: 392202 ELECTRIC PROVIDER PSE (888) 225-5773 TELCO PROVIDER CENTURY LINK (855) 778-3066 PROJECT TEAM CROWN CASTLE A&E FIRM: CROWN CASTLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CROWNAE-APPROVAL@.CROWNCASn- .COM CROWN CASTLE CONTACTS: 1505 WESTLAKE AVENUE NORTH, SUITE 800 SEATTLE, WA 98109 ALICIA POWERS - PROJECT MANAGER (206) 336-3218 CODY CRANK - CONSTRUCTION MANAGER (753) 370.6880 KELSEY PUHALLA - A&E PROJECT MANAGER KELSEY.PUHAL-AQ.CROWNCASTLE.COM (206) 336-2874 SPRINT CONTACT: JENNY KING JKING@MD7.COM 858.964.7427 pate: 60 Comments:Cer,- CROWN CASTLE BU #: 880427 29208 -18TH A, SITE ADDRESS: FEDERAL WAY,WA 98003U TH COUNTY: KING JURISDICTION: CITY OF FEDERAL WAY SPRINT 2.5 DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES T-3 GENERAL NOTES C-1.1 OVERALL SITE PLAN C-1.2 ENLARGED SITE & EQUIPMENT PLAN C-2 EXISTING AND NEW ELEVATION C-3 ANTENNA PLANS C-4 ANTENNA MOUNTING ELEVATION C-5 CONDUIT ROUTING SCHEMATIC C-6 EQUIPMENT SPECIFICATIONS G-1 GROUNDING DETAILS G-2 GROUNDING DETAILS ATTACHED COLLAR MOUNT DETAILS ATTACHED SUPPORT ARM DETAILS ATTACHED DOUBLE ANTENNA CLAMP DETAILS ALL DRAWINGS CONTAINED HEMUN ARE FORMATTED FOR FULL SIZE. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE XVnTl SC C1R RR RP-SPONSIBLE FOR SAME - PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTTVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. SCOPE OF WORK • REMOVE (6) ANTENNAS • INSTALL (3) ANTENNAS • INSTALL (6) RRHs • INSTALL (3) FILTERS • INSTALL (1) 1-7/16" HYBRID CABLE • INSTALL NEW COLLAR MOUNT FINAL CONFIGURATION: • (3) ANTENNAS • (12) RRHs • (3) FILTER .(3) FIBER JUNCTION CYLINDERS • (3) POWERJUNCTION CYLINDERS • (4) HYBRID CABLES DESIGN PACKAGE BASED ON THE APPLICATION ID: 392202 REVISION: 0 THE PAR71F-S ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. 00- AERIAL MAP VICINITY MAP 5 2P91h St Verra - r N 5 269m PI Bali— 7. 3 FesmrRarT s zaoth sr S V lhwnas Kn4nde Sigr®lure Gallery .R Szgls a 5 29M PI A �" a Compeer ;Vad1, � °' ' 5297st PI �rar Orw Perjvnnance S fib.. H y �0r.7 Iv S 293rd 51 a=i r 7 <�Z93rd 41 47.339372, -12L311833 o� Kwan Tip lhoi y �' 0-- L 5 ?361- St - DRIVING DIRECTIONS FROM LOCAL SPRINT OFFICE: NO SCALE DEPART W OCEAN AIR DRTOWARI] SBA PEARL CV, TURN LEFT ONTO CAALE MAR DR MARIPOSA. TURN RIGHT ONTO VISTA SORRENTO PKWY. TURN LEFT ONTO CARMEL MOUNTAIN RD. TAI"E RAMP RIGHT AND FOLLOW SIGNS FOR I-5 NORTH. TAKE RAMP LEFT Ai+ID FOLLOW SIGNS FORT 5 NORTH. BEAR RIGHT RIGHT ONTO WA-" I PAPSTRAIGHT ONTO 1-5 N. ATCiFIC hWY S. ARRIVE AT WAWA- 143. TAKE p CMP RIGHT FOR S. S ON THE RIGHT, IF YODUDREACHFS 2MT14 ST. YOUTE GONE rOO FAR ST TUB APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015 BBC W/ WA.C. AMENDMENTS MECHANICAL. 2015 IMC W/ WA.C. AMENDMENTS ELECTRICAL 2014 NEC W/ W.A.C. AMENDMENTS REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: BY OTHERS MOUNT ANALYSIS: BY OTHERS CALL WASHINGTON ONE CALL (800) 424-5555�e 0 CALL 3 WORIONG DAYS BEFORE YOU DIG1 APPROVALS APPROVAL SIGNATURE SITE ACQ. & ZONING CONSTRUCTION MGR A&E MGR PLANNING CONSULTANT RF MGR PROPERTY OWNER SPRINT REP. DATE Sprint 8040 SOUTH 48T-I STREET, SUITE 200 PHOENIX, AZ 85044 CROWN G CASTLENUE NORTH, SUITE 8W C E, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE , ISSUED FOR IDES./ M ERAB 8/9/20v 1 10:4 :32 AX EDT E C F commuNT ;1l��> v - p'm[ Iota! 17�40152 CX — Cards USA. 1aa. n- Rcg�.#ZVI rr IS A Y101AT1ON ❑F' LAW FORAM PERSON. UNLESS TFfEY ARE RCrI!{G CiND6R TkE DIRE{.7IQN OP A []CENSPSI pROFESSlRNA1.ENG>NlnPR �r['f Ai TFA'lid5 DC?LZZRRHNT � Y--i— C V J L v -;jl � ^ � tLL ✓-1..i tl ��-�� ate^✓ APPROXIMATE LOCATION OF 1 �( PROPERTY LINE (TYP) L L ✓ } r. L✓JJ r. t..�, w yL✓J `4✓J z 7 t 1 Z I( V,( X 1 (U ACCESS ROM 0 4 ofa w 1 f• ^ I (E) TREE (TYP) I K ti ` j� ❑ 1 r ^ ram^ r ^ ,—PARKING LOT ---4 PARKING LOT OVERALL SITE PLAN SCALE: ,•-xa'-a- [ruL size (E) ELECTRICAL SUBSTATION } (E) BUILDING a.... �..,,. _ APPROXMATE LOCATION OF PROPERTY LINE (TYP) r ^ r ^ z tC�v (Cr v (E) BUILDING r- ^ [t(v� �3 J L J �L✓ rr ^ Y ( tC s PARKING LOT rr7 1 W ro m.n. vae O+pl� 1 o _o r _ r ^ tl U J'JJ'1 0 tOL o Vim✓ 1 ram^ Ld L ✓ r 1 r y 00 r"^ 1 Y CL� J (S,Cf 'JJ L✓ V./ L a JJ J L-� Lam✓ l- V✓ LL✓ T � 1 r ^ (E) BUILDING Sprint • 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 µ CROWN CF CASTLEVENUE NORTH, SUITE 800TLE, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 -18TH AVENUE, SOU-1 FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR REV I DESJQ A 6/26/17 ZTK pREL.fAONARY ZTK 0 8/9/17 CWJ CONSTRUCTION RAB Rwb.d A. Rodtc, P.E. prvfi.kmt E Iic:c40152 C. C.& USA, lic Rim RegF -. #2271 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, :r, arzav �nc,xrtr>auur SF=T NUMBER IQ c 1.1 0 J 0 STRUCTURF �W/�MPURTENANC EiEV, a s1 -D HEIGIiF pF STRUCTURE B -0 TIP OF Al'iIF.NHA (E) SPRINT EQUIPMENT: ------r (6) RRHs (6) CYLINDERS MOUNTED TO EXISTING MOUNTS (E) SPRINT EQUIPMENT TO BE REMOVED: (6) ANTENNA. MOUNTED TO EXISTING MOUNTS - EXISTING SPRINT RAO CENTER y ELEV. - B2 -0 (E) 85'-0' MONOPOLE D] tSiING PAD CENTER 2 -0 EXISTING RAO CENTER E7J"V 63 =0"r INSTALLER NOTE: • ALL MOUNTS MUST REMAIN FREE AND CLEAR OF SAFETY CLIMB LINE; CROWN APPROVED MASTHEAD EXTENSIONS MUST BE INSTALLED FOR LINE TO CLEAR ALL MOUNTS. EXISDNG MOUNT MAY HAVE TO BE SPUN FOR T-ARM TO CLEAR LINE. • EQUIPMENT MUST BE KEEP CLEAR OF THE CLIMB PATH. • TOWER IS PAINTED. PAINT TO MATCH TOWER ALL EXISTING k NEW CARRIER EQUIPMENT TO BE REGULATORY COMPLIANT. STRUCTURE W APPURTENANCE ELEV, a 91 -0 HEIGHT OF STRUCTURE hEI 71P OF ANTENNA LLEV. - 85 -0 r/ZA (E) SPRINT EQUIPMENT: (6) RRH9 (6) CYLINDERS MOUNTED TO EXISTING MOUNTS NEW SPRINT EQUIPMENT: (3) ANTENNAS (6) RRHs (3) FILTERS MOUNTED TO NEW MOUNTS EXISTING SPRt fL RAO CENTER EiEV. - (E) 85'-0- MONOPOLE EXISTING RHO CE2 -0NT L.V. .. ER Ewsnwc RAD cENTE1t . � 3- Sprint 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 FCROWN CASTLE I�FUB ivORTH, SUITE 800I , WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR I (E) SPRINT FEEDLINES: REV DATE DRWN DESCRIMON IDES./Q (E) SPRINT FEEDUNES: (1) ANDREW - LDF4-50A (1/2") (1) ANDREW - LDF4-50A (1/2-) A 6/26/17 ZTK PRELD4INARY ZTK (3) SAMSUNG TELECOMMUNICATIONS - TYPE 2 (1-7/16-) II (3) SAMSUNG TELECOMMUNICATIONS - TYPE 2 (1-7/16") 0 8/9/17 CWJ CONSTRUCITON RAR SPRINT EQUIPMENT I SPRINT EQUIPMENT ANTENNA CL• 82'-0- NEW SPRINT FEEDLINE: (1) SAMSUNG TELECOMMUNICATIONS - TYPE 2 (1-7/16") ANTENNA CL• 82'-0' MOUNT CL 82'-0" I MOUNT CL• 82'-0' II INSTALLER NOTE: INSTALLER NOTE: DIRECT TOWER MOUNTED EQUIPMENT MUST I t DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/ CUMBING II II NOT TRAP OR INTERFERE W/ CLIMBING PEGS/STEPS AND SAFETY CLIMB. PEGS/STEPS AND SAFETY CLIMB. - l � F]OSONG SPRINT GPS II EIOSTWG SPRINT CPS - _Q . I II 1 I I I I I a/9T14):4�)Z EXISTING ELEVATION SCALE: NOT TO SCALE 2 FINAL ELEVATION SCALE: NOT TO SCALE Rihu3A. B.cIM P3L p...f.d.,,,.1 Eap, L 40152 C= C.,k USA. Inc ri— Re —ucti #2Z7t LT IS A VIOLATION OP LAW FOR ANY PERSON, UNLESS THEY ARE ACIYNG UNDERTHE DIRECITON OF A UCENSED PROFESSIONAL ENGINE8l4 SHEET NUMBER: SIO J SAMSUNG T C2 (GAMMA) 240' AZIMUTH AT A2 (E) SPRINT ANTENNA [ALPHA) TO BE REMOVED V AZIMUTH �5+OASUNG TELECOMMUNICATIONS - OPTIC FIBER JUNCTION CYUNDER 82 (3 TOTAL, 1 PER SECTOR) EXISTING ANTENNA LAYOUT SCALE: NOT TO SCALE NEW 2-1/2" (2-7/8" O.D.) SCH 40 x 6'-0' LONG PIPE W/ ASSOCIATED HARDWARE (9 TOTAL, 3 PER SECTOR) NEW SPRINT DOUBLE ANTENNA CLAMP VALMONT - DAC (6 TOTAL) NEW COLLAR MOUNT VALMONT - LWRM (2 TOTAL) NEW SPRINT RRH SAMSUNG TELECOMMUNICATIONS - BOOMHz RRH (6 TOTAL, 2 PER SECTOR STACKED) (E) 85'-0- MONOPOLE ,Hz RRH—V3 (E) SPRINT SPUTTER SAMSUNG TELECOMMUNICATIONS - POWER JUNCTION CYLINDER (3 TOTAL, 1 PER SECTOR) B1 (BETA) 135' AZIMUTH NEW SPRINT ANTENNA KMW COMMUNICATIONS - ETCR-654L12H6 (3 TOTAL, 1 PER SECTOR) (E) SPRINT RRH - SAMSUNG TELECOMMUNICATIONS - RRH-P4 (3 TOTAL, 1 PER SECTOR) Cl (GAMMA) 240''AAZIMUTH I� 1 INSTALLER NOTE: ALL MOUNTS MUST REMAIN FREE AND CLEAR OF SAFETY CLIMB LINE: CROWN APPROVED MASTHEAD EXTENSIONS MUST BE INSTALLED FOR UNE TO CLEAR ALL MOUNTS. EXISTING MOUNT MAY HAVE TO BE SPUN FOR T-ARM TO CLEAR UNE. EQUIPMENT MUST BE KEEP CLEAR OF THE CLIMB PATH. • TOWER IS PAINTED. PAINT TO MATCH TOWER ALL EXISTING k NEW CARRIER EQUIPMENT TO BE REGULATORY COMPLIANT. NEW SPRINT FILTER RFS/CELWAVE - FIM800CAB-C2D (3 TOTAL, 1 PER SECTOR) NEW 8" SUPPORT ARM VALMONT - MM01 (6 TOTAL) 3 NEW RRH LAYOUT SCALE: NOT TO SCALE w A ` (ALPHA)W1/2" 0'H PLACE EXISTING PIPE MOUNTS WITH rRESTD (2-7/B" O.D.) GALV. 40 PIPE AS REQ'D. (E) SPRINT RRH SAMSUNG TELECOMMUNICATIONS - 2.5GHz RRH-V3 (3 TOTAL, 1 PER SECTOR) (E) 85'-0- MONOPOLE L (E) SPRINT SPUTTER SAMSUNG TELECOMMUNICATIONS - OPTIC FIBER JUNCTION CYLINDER (3 TOTAL, 1 PER SECTOR) FINAL ANTENNA LAYOUT 2 SCALE: NOT TO SCALE 2 NOT USED NOT NOT TO SCALE (E) SPRINT SPUTTER SAMSUNG TELECOMMUNICATIONS - POWER JUNCTION CYUNDER (3 TOTAL, 1 PER SECTOR) 81 Sprint . 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 ' CROWN CASTLE 1505 WPSn AKE AVENUE NORTH, SUITE 800 SEATIT.E, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEAM 135� (BETA) 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE REVI DATE I DAWN DPSCRIPDON 1:)E4./Q A 6/26/17 ZTK PRELUA]NARY ZTK 0 6/9/17 CWJ CONSTRUCITON RAH 8/9/2017 1 10:49:32 AM EDT Ri,h.M A. 13-1mr, P.E. Pmf-b.A Fme—L;,v.,..• 40152 Crown Cowie USA, Iu F 1114m aunn #2271 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER j TO AI- RTITIS DOMMEiT. SHEET NUMBER SId C-3 0 Gb. IF- ID- B1BFC20B1313E4648-912833FACBMBES CROWN CASTLE SITE IHORKGENERAL NOTES: 1. THE SUBCONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 2. ALL EXISTING ACTIVE SEWER, WATER. GAS. ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK. SHALL BE RELOCATED AS DIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE SUBCONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES, SUBCONTRACTOR S14ALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW- THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION. 3. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE TOWER SITE" AND LATEST VERSION OF TIA 1019 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 4. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS. 5. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 6. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR. OWNER AND/OR LOCAL UTILITIES. 7. THE SUBCONTRACTOR SHALL PROVIDE SITE STOWAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE. 8. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS. 9. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 10. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 11. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE PROJECT SPECIFICATIONS. 12. SUBCONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL 13. NOTICE TO PROCEED- NO WORK TO COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF A PURCHASE ORDER. 14. ALL CONSTRUCTION MEANS ANO METHODS; INCLUDING BUT NOT UMTIET} TO, ERECTION PLANS. RIGGING PLANS, CLIMBING PLANS. AND RESCUE PLANS SHALL 6E THE RESPONSEBILIT'1' OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN AND SHALL MEET Msl/TIA 1019 (LATEST EDITION), OSHA, AND GENERAL INOUST RY STANDARDS. ALL RIGC ING PLANS SHALL ADHERE TO ANSI/m--1019 (LATEST EDITION) INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION. SPRINT CONSTRUCTION NOTES MUST COMPLY WITH ALL APPLICABLE ADOPTED CODES AND STANDARDS, AND PORTIONS THEREOF. SPRINT METHOD OF PROCEDURE (MOP) AND SPRINT STANDARDS AT THE TIME OF CONSTRUCTION START. PRECEDENCE: SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE STANDARD DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS. INFORMATION ON THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. ALONG WITH SPRINT CONSTRUCTION MANAGER APPROVAL. SITE FAMILIARITY: CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON -SITE P RVI ION: THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. D&WINGS„SEE T JOSSITE THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUITE JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CORSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK- DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE- MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. IN jRDANCE WITH COMPANY PRACTICE. CONTRACTOR MAY BE REQUIRED TO PICK UP MATERIAL AT LOCATION PRESCRIBED BY SPRINT. SECTION 01 300 - CELL SITE CONSTRUCTION NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS, CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS. 5ECTION 01 •00 - SUBMITTALS AND. TESTS AI TERNATIVE& AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINT'S CONSTRUCTION MANAGER FOR APPROVAL SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED. TESTS AND INSPECTIONS: A THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER TS-200 REV 5 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOWNTILT: PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING A COMMERCIAL MADE -FOR PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (MT). INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. 4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS - ANTENNA ALIGNMENT TOOL (AAT) 2. SWEEP AND FIBER TESTS. 3. SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT. 4. ALL AVAILABLE JURISDICTIONAL PERMIT AND OCCUPANCY INFORMATION. S. PDF SCAN OF REDLINES PRODUCED IN FIELD. B. A PDF SCAN OF REDUNE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS -BUILT DRAWING PRODUCTION. 7. LIEN WAIVERS. 8. FINAL PAYMENT APPLICATION. 9. REQUIRED FINAL CONSTRUCTION PHOTOS. 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS. 11. APPLICABLE POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA (SPRINT'S DOCUMENT REPOSITORY OF RECORD). 12. CLOSEOUT PHOTOGRAPHS AND CLOSEOUT CHECKLIST: SPRINT WILL PROVIDE SEPARATE GUIDANCE. a. PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING LIST. ADDITIONAL PHOTOS MAY BE REQUIRED TO SUPPORT ACCEPTANCE PROCESSES (I) BACK MAIN FIBER CABLE ROUTE (MINIMUM TWO PHOTOS) (ii) OF EACH ANTENNA AND RRU (iii) MANUFACTURERS NAME TAG FOR ALL SERIALIZED EQUIPMENT (iv) PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRU'S AND RIBS (DOOR OPEN) (v) REIS CABINET WITH DOOR OPEN SHOWING MODIFICATIONS (vi) POWER CABINET, DOORS OPEN, BATTERIES INSTALLED (Ai) BREAK OUT CYLINDERS (viii) ASR SIGNAGE FOR SPRINT OWNED TOWERS (ix) RADIATION EXPOSURE WARNING SIGNS (x) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER OF ANY NEW ANTENNA AT HORIZON. b. LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15. IN 15 CREATE NEW CATEGORY; 2.5 DEPLOYMENT, AND SECTION; PERMANENT CONSTRUCTION. LABEL PHOTOS WITH SITE CASCADE AND VIEW BEING DEPICTED. CAMERAS USED TO TAKE PHOTOS SHALL BE GPS ENABLED SUCH THAT THE GPS COORDINATES ARE INCLUDED IN THE PHOTO MEDIA -FILE INFORMATION. PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION INTEGRATION: DOCUMENTS. PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS METHODS.. OF PROCEE5,3E_I I'Sj�Si13Sa1Y,i1-`ils,i`QM,' CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND COMMISSIONING MOPS. CONTRACTOR IS RESPONSIBLE FOR DISTRIBUTION OF LATEST MOPS. A TOP HAT B. HOW TO INSTALL A NEW CABINET C. BASE BAND UNIT IN EXISTING UNIT D. INSTALLATION OF BATTERIES E. INSTALLATION OF FIBER CABLE F. INSTALLATION OF RRU'S G. CABLING H. TS-0200 REV 5 - ANTENNA LINE ACCEPTANCE STANDARDS I. SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1. J. COMMISSIONING MOPS SECTION 01 ZOO - COMPANY FURNISHED MATERIAL AND EQUIPMENT A COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. B. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. C. CONTRACTOR IS RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION SECTION 09 900 - PAINTING QUALITY ASSURANCE: A COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS. MATERIALS; A MANUFACTURERS: BENJAMIN MOORE. ICI DEVOE COATINGS, PPG, SHERWIN WILLIAMS OR APPROVED PROVIDE PREMIUM GRADE, PROFESSIONAL -QUALITY PRODUCTS FOR COATING SYSTEMS. PAINT SCHEDULE - A. EXTERIOR ANTENNAE AND ANTENNA MOUNTING HARDWARE: ONE COAT OF PRIMER AND TWO FINISH COATS. PAINT FOR ANTENNAE SHALL BE NON-METALLIC BASED AND CONTAIN NO METALUC PARTICLES. PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE OF ANTENNAE ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER. REFER TO ANTENNA MANUFACTURER'S INSTRUCTION WHENEVER POSSIBLE. B. WATER TANKS: TOUCH UP - PREPARE SURFACES TO BE REPAIRED. FOLLOW INDUSTRY STANDARDS AND REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND FINISH. PAINTING APPLICATION, 1. INSPECT SURFACES, REPORT UNSATIL .RY CONDITIONS IN WRITING; BEGINNING WORK MEANS ACCEPTANCE OF SUBSTRATE. 2. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR PREPARATION, PRIMING AND COATING WORK. COORDINATE WITH WORK OF OTHER SECTIONS. 3. MATCH APPROVED MOCK-UPS FOR COLOR, TEXTURE, AND PATTERN. RE -COAT OR REMOVE AND REPLACE WORK WHICH DOES NOT MATCH OR SHOWS LOSS OF ADHESION. 4. CLEAN UP, TOUCH UP AND PROTECT WORK. 1. GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER TOWER ERECTION WITH-GALVANOX," "DRY GALV,- OR -ZINC-IT".- 2. FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO THE COMPONENTS, THEIR PRESERVATIVE TREATMENT, OR THEIR PROTECTIVE COATINGS. SF&JIM I I ZW - ANTENNA ASSEMBLY --- REMOTE RADIO NNO AND CASILF INSTAl-LATION SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRU'S, AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. ANIWNAS ANO RRU'S: THE NUMBER AND TYPE OF ANTENNAS AND RRU'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. NV FIBER CABLE: EXISTING NV FIBER CABLE WILL BE USED AT EACH SITE. CABLE SHALL BE USED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTIONS: FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRU'S AND ANTENNAS, JUMPERS SHALL BE TYPE LDF 4, FLC 12-50. CR 540. OR FXL 540. SUPER -FLEX CABLES ARE NOT ACCEPTABLE JUMPERS BETWEEN THE RRU'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2' FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MINIMUM LENGTH FOR JUMPER SHALL BE SO AS TO ALLOW FOR THE PROPER BEND RADIUS PER MANUFACTURER OR SPRINT SPECIFICATIONS. REMOTE FLECTRICAL TILl (RLY) CABLES: MISCELLANEOUS, IS• INSTALL SPUTTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH AND FEED ORIENTATION INFORMATION SHALL BE AS DESIGNATED ON THE CONSTRUCTION DRAWINGS. A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE CONSTRUCTION DRAWINGS. FIRER CABLE INSTALLATION: A THE CONTRACTOR SHALL ROUTE, TEST AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. -THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAT THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION 1. FASTENING MAIN FIBER CABLES: a. LATTICE ND GUYED TOW RS: ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0' OC USING NON-MAGNETIC STAINLESS STEEL CUPS. HOISTING GRIPS SHOULD BE INSTALLED AT MID -POINT IF CABLE RUN EXCEEDS 200' AS WELL AS TOP SIDE. a. MONOPOLE: ALL CABLES SHALL BE PERMANENTLY SUPPORTED WITH HOISTING GRIPS AT INTERVALS OF NO MORE THAN 200' (ONE HOISTING GRIP PER COAX). 1. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA). WITHIN THE MMSS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES. a. FIBER: SUPPORT FIBER BUNDLES USING 1/2" VELCRO STRAPS OF THE REQUIRED LENGTH AT 18' O.C. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12.000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. 2. FASTENING OR SECURING JUMPERS SHOULD CONSIST OF STAINLESS STEEL CLIPS, 18' FROM REAR OF CONNECTOR AND 24' THEREAFTER AND AT NO TIME SHALL THEY CONTACT TOWER OR STRUCTURAL STEEL 3. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE. NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOPE AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. c. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM BEND RADIUS. Spri nt 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 CROWN CASTLE L ENUE NORTH, SUITE 800E, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA10 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR RSV DATE DRWN DESCRIPTION IIDES./Q A 6/26/17 ZTIC PREI.AEIARY ZTK 0 8/9/17 CWI CANSTRUCITON RAB Richad A Bodos, P.E. P-Eeae -d E,n&-Iirearc 40152 Cm Cletle USA, I= F Regis=&n #2271 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION UNES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. SIiEETNUMBEP- Vi510 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV S. /�J A 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY A _ 2 rV' ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1. WFAI,FRPRO_Km A ALL FIBER AND COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. SELF-wdALCV,VVn NG TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF AMALGAMATING TAPE. 2. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. 3. JMA-WPS SERIES ENCLOSURE. 4. BUM AND TAPE, 1 COMPLETE WRAP OF 3/4" PRE -TAPE, BUTYL WRAPPED IN HALF INCH LAP LAYERS, ENDED WITH SHINGLED DOWNWARD 3 WRAPS OF 2" TAPE, 3 WRAPS OF 3/4" TAPE SHINGLED DOWNWARD, FREE OF WRINKLES, BUCKLES AND FLAGGING. S. Po FLAME ON JOB SIM 12 NOT ACCEPTABLE C. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE CONSTRUCTION DRAWINGS. A THE CONTRACTOR SHALL ROUTE, TEST AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAT THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN FIBER CABLES: a. LATTICE AND GUYED TOWERS: ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0" OC USING NON-MAGNETIC STAINLESS STEEL CUPS. HOISTING GRIPS SHOULD BE INSTALLED AT MID -POINT IF CABLE RUN EXCEEDS 200' AS WELL AS TOP SIDE. b. MONOPOLE: ALL CABLES SHALL BE PERMANENTLY SUPPORTED WITH HOISTING GRIPS AT INTERVALS OF NO MORE THAN 200' (ONE HOISTING GRIP PER COAX). 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA). WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES. a. FIBER: SUPPORT FIBER BUNDLES USING 1/2" VELCRO STRAPS OF THE REQUIRED LENGTH AT 18" O.C. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL b. DC: SUPPORT OC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL 3. FASTENING OR SECURING JUMPERS SHOULD CONSIST OF STAINLESS STEEL CLIPS, 18" FROM REAR OF CONNECTOR AND 24" THEREAFTER AND AT NO TIME SHALL THEY CONTACT TOWER OR STRUCTURAL STEEL. 4. CABLE INSTALLATION: 0. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE. NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOPE AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. C. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM BEND RADIUS. 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS. 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 5. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1. WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CASIf GROUND KIT& A ALL FIBER AND COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. SELF -AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF AMALGAMATING TAPE. 2. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED 3. JMA-WPS SERIES ENCLOSURE. 4. BUTYL AND TAPE, 1 COMPLETE WRAP OF 3/4" PRE -TAPE, BUM WRAPPED IN HALF INCH LAP LAYERS, ENDED WITH SHINGLED DOWNWARD 3 WRAPS OF 2" TAPE, 3 WRAPS OF 3/4" TAPE SHINGLED DOWNWARD, FREE OF WRINKLES, BUCKLES AND FLAGGING. 5, OPEN FLAMES{OS SITE 15. NOT_ACCEPiABLE SUMMARY: A- THIS SECTION SPECIFIES MUSS CABINETS, POWER CABINETS, AND INTERNAL EQUIPMENT INCLUDING BUT NOT UMNIED TO RECTIFIERS, POWER DISTRLBITION UNITS, BASE BAND UNITS, SURCE ARRESTORS, BATTERIES, AND SIMILAR EQUIPMENT FURNISHED BY THE COMPANY FOR INSTALLATION BY THE CONTRACTOR (OFCI). B. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS MATERIALS AND PROVIDE ALL LABOR REQUIRED FOR INSTALLATION EQUIPMENT IN EXISTING CABINET OR NEW CABINET AS SHOWN ON DRAWINGS AND AS REQUIRED BY THE A R.E INSTALLATION MOPS. C. COMPLY WITH MANUFACTURER'S INSTALLATION AND START-UP REQUIREMENTS. DC CIRCUIT BREAKER LABELING: A LABEL CIRCUIT BREAKERS ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1 SECTION 26 TOO - BASIC ELECTRICAL REQUIREMENTS SUMMARY: THIS SECTION SPECIFIES BASIC ELECTRICAL REQUIREMENTS FOR SYSTEMS AND COMPONENTS. A ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND LISTINGS WHERE SUCH LABELS AND LISTING ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE NEW USE FOR THIS PROJECT. C. MATMW.% AND E U� ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE WE MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS. SUPPORTING DEVICES: A MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS. PROVIDE PRODUCTS BY THE FOLLOWING: 1. AWED TUBE AND CONDUIT. 2. B-LINE SYSTEM. 3. UNISTRUT DIVERSIFIED PRODUCTS. 4. THOMAS k BETTS B. FASTENERS: TYPES, MATERIALS AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE. 2. POWER -DRIVEN THREADED STUDS: HEAT -TREATED STEEL DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 3. FASTEN BY MEANS OF WOOD SCREWS IN WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOLID MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING -TENSION CLAMPS ON STEEL 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. B. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WITH NEC. B. COORDINATE WITH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: 1. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. 2. USE VIBRATION AND SHOCK -RESISTANT FASTNERS FOR ATTACHMENTS TO CONCRETE SLABS. ELECTRICAL IDENTIFICATION: A UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET, INSIDE DOORS OF AC PANEL BOARDS WITH ANY CHANGES MADE TO THE AC SYSTEM. B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANELBOARD. SECTION 26 200 - ELECTRICAL M61fSK$ AND EQUIPMENT CONDUIT: A RIGID GALVANIZED STEEL [RCS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED LNTERIOR LOCATIONS AND FOR UNDERGROUND RUNS. RIGID CONDUIT AND FITTINGS SHALL BE STEEL - COATED WITH IINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1. FEDERAL SPECIFICATION WW-C-Sal AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SKILL BE THREADED - SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS CONDUITS SHALL BE MANUFACTURED BY AWED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL C. TRANSITIONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. 0. ALL UNDERGRDUND CONDUIT OR CONDUIT IN CONCRETE SHOULD BE PVC, EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEILINGS. EMT SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO-GALVANIZED OR HOT-01PIRED GALVANIZED AND PRODUCED TO ANSI SPECIFICATIONS C80.3, FEDERAL SPECIFICATION WED--C-S63. AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATfAND. OR APPROVED EQUAL FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. E. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FWAL CONNECTION TO EQUIPMENT FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTNLGS, MAINTAINING THE INTEGRITY OF CONDUT SYSTEM- SET SCREW CONNECTIONS SWILL NOT BE ACCEPTABLE. MAXIMUM LENGTH OF FLJ70BLE CONDUIT SHALL NOT EXCEED 6-FEET- LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRED BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL. F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21MM) HUBS AND BOXES: A AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED HUB SHALL INCLUDE LOCK NUT AND NEOPRENE 0-RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY 0-Z/GEDNEY OR EQUAL BY ROXTEC. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO - CL2075, OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE-HINDS WAR SERIES OR EQUAL D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKET COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION, PROVIDE CROUSE-HINDS FORM 8 OR EQUAL E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN. SQUARE -D", CROUSE-HINDS, COOPER, ADALET, APPLETON. 0-Z GEDNEY. RACO, OR APPROVED EQUAL SUPPLEMENTAL GROUNDING SYSTEM: A FURNISH AND INSTALL A SUPPLEMENTAL CROUNDING SYSTEM TO THE EXTENT INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NONMAGNETIC STAINLESS STEEL CLIPS WITH RUBBER GROMMET, GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLID BARE OR INSULATED CONDUCTORS EXCEPT AS OTHERWISE NOTED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EJLCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO -HOLE SPADES WITH NO-OX. C. STOLEN GROUND -BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CONSTRUCTION MANAGER FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. EXISTING STRUCTURE: A EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES. DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTIUZED IN THE COUPLE" PROJECT SHALL BE REMOVED OR DE -ENERGIZED AND CAPPED IN THE WALL, C£IUNC, OR FLOOR SO THAT THEY ARE CONCEALED ANO SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION. CONDUIT A CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANOETtS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE. MAINTAIN CLOSE PROXIMITY TO THE STRUDTURE AND KEEP CONDUITS IN TIONT EWELOPES, CHANGES IN 04RECTONI TO ROUTE AROUND OBSTACLES SKILL BE MADE WITH CONDUT OUTLET BOOZES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEIUNG LINES. ALL CONOUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPCPARILY CAPPED TO PREVENT COWREM. PLASTER OR DIRT FROM ENTERING, CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE WITH ACCEPTED GOOD PRACTICE. • GC IS RESPONSIBLE FOR HIRING ALL 3RD PARTY SPECIAL INSPECTIONS AS REQUIRED PER MUNICIPALITY • GC IS RESPONSIBLE FOR VERIFYING ALL FIELD MEASUREMENTS PRIOR TO STARTING CONSTRUCTION • DO NOT OPEN RRU PACKAGES IN THE RAIN • NO OPEN FLAME ON SITE • GC TO ENSURE HYBRIDS ARE SUPPORTED EVERY 3'-0" ON HORIZONTAL AND 4'-D" ON VERTICAL RUNS Sprint 8040 SOUTH 49TH STREET, SUITE 200 PHOENIX, AZ 85044 CROWN CASTLE 1505 WEST"M AVENUE NORTH, SUITE SM SEATIT E, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEAI23 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR 'REV DATE DRWN DESCRIPITON IDES./Q A 6126/17 ZTK PRELD0111IARY - 0 8/9/17 CWJ CONSTRUCTION RAE T10:4:32 8/9/2 Rkhwd A EocItM PJL Pros .d U,:e n Iu 10152 Cm-m Cwk USA, Ix Firm RgPW- ioa OWL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A UCENSED PROFESSIONAL ENGINEM -M AI_T1RTELS OCX.iJi[B:T. SHEETNUMHEIL• F.VISIO 'T-3 � T�x x x x x x x 11 (E) UTILITY FRAME (TW) x X . Ulm (E) GENERATOR x x x x x RINT 6'-6"x12'-0" ETE PAD x x x x x (E) x CONCRETE PAD x % k % % x x x I 25'-6"t ENLARGED SITE PLAN SCALE: s/a -r-o {ru1L SIZE) 9 (E) SPRINT CIENA BOX (E) SPRINT UTILITY FRAME (lYP) (E) SPRINT POWER CABINET EQUIPMENT PLAN SCALE: r-+'—o• (rT1u SIZE) �f (E) DISCONNECT (TMP) (E) METER (n'P) Sprint 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 8W SEATTLE, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 - 18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR :RSV DATE DRWN DPSGRWnON GES./Q A 6/26/17 ZTK PRELMUNARY ZTK 0 8/9/17 CWJ CONSTRUCnON RAB Ridh aw A.Bodtee,P.R P-Ii. -1 E 1i— 40152 C—C &USA, I—Fim Rege¢a —N2211 IT IS A VIOLATION OF LAW FOR ANY PB1tSON, UNLESS THEY ARE ACnNG UNDER THE DIRECITON OF A LIC@ISED PROPPSSIONAL HNGIlVEEIU TOALTTHIS DOCVMEMiT. SHEET NUMBERC6DC-1.2 KEYED CABLE LEGEND Ol 1/2- RF JUMPERS O POWER/FIBER © RET NEW KMW COMMUNICATIONS - ETCR-6; NEW SPRINT SAMSUNG TELECOMMUNICATIONS - 801 (E) SPRINT ANTENNA MOUNTING ELEVATION SCALE: NOT TO SCALE • ALL MOUNTS MUST REMAIN FREE AND CLEAR OF SAFETY CLIMB LINE; CROWN APPROVED MASTHEAD EXTENSIONS MUST BE INSTALLED FOR LINE TO CLEAR ALL MOUNTS. EXISTING MOUNT MAY HAVE TO BE SPUN FOR T-ARM TO CLEAR LINE. • EQUIPMENT MUST BE KEEP CLEAR OF THE CLIMB PATH. • TOWER IS PAINTED. PAINT TO MATCH TOWER ALL EXISTING do NEW CARRIER EQUIPMENT TO BE REGULATORY COMPLIANT. :TOR 1Hz RRH NG) NEW SPRINT RFS/CELWAVE - FIMBOOCAS-C20 -1/2' STO IA MOUNTING PIPE 5'-0' POLE HYBRID CABLES HYBRID CABLE Sprint , 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 CCCROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 lsl SEATTLE, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEAM 29208 -18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR DATE DAWN DESCRIPTION PRELIDENARY FA B/9/l7 CWJ CONSTRUCTION RAB Rkh-11A - Bo ]ate P.E. I4o( aioml Eog—Iiceose 40152 Cm Caede USA, I= Pig Regiee n #2271 IT S A VIOLATION OF TAW FOR ANY PERSON, UNLESS THEY ARE ACTING UND13RTHE DIRECTION OF A LICENSED PROFESSIONAL ENGINEIM SHEET NUMBER 510 �-4 � 0 0 ° e e e ° e ° ° e a a 0000 oaoo IIII ° 0o0o 0000 ° KMW COMMUNICATIONS — ETCR-654L72H6 SAMSUNG TELECOMMUNICATIONS — 80OMHz RRH RFS/CELWAVE — FIMBOOCAB—C2D WEIGHT (WITHOUT MOUNTING HARDWARE): 79.4 LBS WEIGHT: 59.5 LBS. WEIGHT: 53.0 LBS SIZE (HxWxD): 72.Ox21.Ox6.3 IN. SIZE (HxWxD): 18.001.005.4 IN. SIZE (HxWxD): 15.2x9.65x8.5 IN. RATED WIND VELOCITY: 150.0 MPH KMW COMMUNICATIONS - ETCR-654L12H6 SAMSUNG TELECOMMUNICATIONS - 800MHz RRH RFS/CELWAVE - FIM800CAB-C2D SCALE: NOT TO SCALE 2 SCALE: NOT TO SCALE 3 SCALE: NOT TO SCALE Sprint 8040 SOUTH 48TH STREET, SUITE 200 PHOENIX, AZ 85044 CROWN CASTLE 1505 WESTL AKE AVENUE NORTH, SUITE 8W SEAT . WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 -18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR REV DATE DRWN DESCRIPTION DIMJQ A 6/26/17 ZTK PRBLUMNARY ZTK 0 8/9/17 CWJ CONSTRUCTION RAB Ruud A. B-I m P.H. P.E.&-IllW Li-40152 C_ Castle USA, I— I— Reg� #2271 IT 18 A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, SHEET NUMBER:6 (70 SSO NOT USED NOT USED NOT USED iII,( 4 SCALE: NOT TO SCALE 5 SCALE: NOT TO SCALE � SCALE: NOT TO SCALE C ^ J TO ANTENNA COAX TERRABAR GROUND BAR Ojg-RO[OI0o000000000000 0 0 0 00000000000000 Q 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TWO HOLE LONG BARREL COMPRESSION LUG (TYP) NOTES, 1. DOUBLING UP 'OR STACKING' OF CONNECTIONS IS NOT PERMITTED. 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL ANTENNA GROUND BAR DETAIL SCALE: NOT TO SCALE TO ANTENNA COAX — TERRABAR GROUND BAR i OFoj�0900o0o00000000 00000000000000000 pIlp 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 p J #2 SOLID TINNED COPPER CONDUCTOR TO TOWER/SHELTER TWO HOLE LONG BARREL COMPRESSION LUG GROUND RING (2 TYP. FOR (TYP) BOTTOM GROUND BAR ONLY) NOTES: 1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY). 3. INSTALL GROUND BARS AT 75 FT. INTERVAL MAXIMUM. 4. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER. TOWER/SHELTER GROUND BAR DETAIL SCALE: NOT TO SCALE 8' PVC PLUG f 8- PVC PLUG CPLG. (THRD.) T/FINISH GRADE N SUBGRADE o /2LGR-OUNDRING P) z B" PVC SCH 40 PIPE 2 ENTRANCE OF o EXOTHERMIC WELD RE � I I —III LLI III— — I —III I1 1 TRENCH BOTTOM '— 2/0 TINNED CU EXTERNAL CADWELD TEST LOOP TO TOWER GROUND RING WIRE GROUND RING WIRE NOTES: - 5/0' 0 x 10'-0' LONG COPPER CLAD GROUND ROD 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL 2. GROUND WIRE SHALL BE MIN. 30- BELOW GRADE OR 6' BELOW FROST UNE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) 3 INSPECTION WELL DETAIL SCALE: NOT TO SCALE STAINLESS STEEL BOLT (TYP) STAINLESS STEEL TO TOWER MOUNTED EQUIPMENT FLAT WASHER () MONOPOLE 2-HOLE CRIMP/ (�) TO ANTENNA COMPRESSION ANTENNA GROUND BAR CONNECTOR [ LOCATED AT MCL GROUND I ! (BONDED TO TOWER STEEL) BAR STANDARD COAX i 2 HOLE LUG (TYP) CABLE GROUND KIT - STAINLESS STEEL (TYP) FLAT WASHER 6 AWG STRANDED Cu WIRE -- 4 STSTEELAINLESS - () 6' WIDE METALLIC HTEL WITH GREEN, 60OV, THWN BELLVILLE WASHER STAINLESS STEEL NUT WARNING/LOCATOR TAPE AT INSULATION (OR AS PROVIDED I (TYP) (TYP)GRADE — 12' DEPTH WITH GROUND KIT) (TYP) SINGLE CONNECTORAT GROUND BIERS N I W STAINLESS STEEL BOLT o z — MECHANICAL CONNECTION (TYP) STAINLESS STEEL 0•' z FLAT WASHER wEXOTHERMIC WELD ANTENNA GROUND BAR o COAX CABLE BOTTOM OF MONOPOLE w (TYP FOR ALL) DRAGON TOOTH WASHER N (�) STEEL ------- ----'--� TO BTS EQUIPMENT VIA 2/0 TINNED BARE TRAY OR ICE BRIDGE 1 i COPPER WIRE 2-HOLE CRIMP/ STAINLESS STEEL GROUND RING #2 COPPER WIRE MONOPOLE PIER COMPRESSION FLAT WASHER SOLID, TINNED FOR CARRIER AND ICE CONNECTOR BRIDGE GROUND LOOP GROUND WIRE Vj �) SEE NOTE 3 STAINLESS STEEL NUT STAINLESS STEEL GROUND RING 2/0 FOR GROUNDORE i '1 BELLVILLE WASHER (�) TOWER GROUND LOOP (TYP) ------ ��SINGLE CONNECTORAT EEEL 0134EUS INSPECTION WELL -- EXOTHERMIC WELD (TYP) I STAINLESS STEEL NOTES,' I SELF DRILLING STAINLESS STEEL 1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA METAL SCREW FLAT WASHER LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE (TYp) (TYP) GROUND ROD COPPER MIN. TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED. CLAD STEEL ROD LONG 5/8 0 x 10'-0" LONG 2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE TOWERS. 2-HOLE CRIMP/ ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN AND -OXIDANT COATING. COMPRESSION zhomaw CONNECTOR 3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OF ANSI/T1A 222 AND NFPA 780. DRAGON TOOTH METALLIC OBJECT NOTES, WISHER 1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE (TYP) VERTICAL SINGLE CONNEMR AT METALLIQ/STEEL 0.8JECTS 2. GROUND WIRE SHALL BE MIN. 30' BELOW GRADE OR 6' BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D) 4 TYPICAL ANTENNA CABLE GROUNDING SCALE: NOT TO SCALE 5 HARDWARE DETAIL FOR EXTERIOR CONNECTIONS SCALE: NOT TO SCALE GROUND ROD DETAIL SCALE: NOT TO SCALE Sprint 8040 SOUTH 49M STREET, SUITE 200 PHOENIX, AZ 85044 X^' CROWN CASTLE_ IS05 WESTLAKE AVENUE NORTH, SUITE 8W SEATTLE, WA 98109 SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 -18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR RWj DATE I DRWN DESCRIFll'ION IDES./Q A 6/26/17 2TK PRELIMINARY 2TK 0 B/9/17 LWl CONSTRUCI40N RAE C 4 8/9/2017 1 10:i-!32 AM EDT Rkb.d A. BoeU¢, PIL Fm(oaio" Eu&o I *—= 401152 m CCade USA, Inc F RcWmm #227t IT IS A VIOIATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECITON OF A LICENSED PROFESSIONAL ENGINEER, SHEET NUMBBR SO �-1 0 WIRE SIZE BURNDY LUG BOLT SIZE #66 AWG GREEN INSULATED YA6C-2TC38 3/8' - 16 NC S 2 BOLT TYPESprint TYPE HS TYPE 2-YA-2 TYPE %A TYPE YA-2 IYEESxY #2 AWG SOLID TINNED YA3C-2TC38 3/8' - 16 NC S 2 BOLT #2 AWG STRANDED YA2C-2TC38 3/8' - 16 NC S 2 BOLT 8040 SOUTH 48TH STREET, SUITE 200 _ #2/0 AWG STRANDED YA26-2TC38 3/8' - 16 NC S 2 BOLT PHOENIX, AZ 85044 #4/0 AWG STRANDED YA28-2N 1/2" - 16 NC S 2 BOLT NPE W TYPE VN TYPE NC TYPE SS TYPE GR BURNDY GROUND LUG W/ -HEAT SHRINK LONG BARREL (CLEAR) (SEE CHART) _NG CC CASTLE NUT ) CQNDuGITOR FCROWI]N VENUE NORTH, SULOCK WASHER TI E, WA 98109 �J (TYP) TYPE VS ]YPE VB TYPE 3I TYPE Gr NOTE, 1. ERICO EXOTHERMIC 'MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 2. MOLD TYPE ONLY M BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD. CADWELD GROUNDING CONNECTIONS SCALE: NOT TO SCALE M Al (TYPICALLY) ANTENNA CABLE 12' TO 24' 120 MAX. WEATHERPROOFING KIT (SEE NOTE 3) - CABLE GROUND KIT -- - - #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 CABLE CONNECTOR NOTES, 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED. CABLE GROUND KIT CONNECTION 3 SCALE: NOT TO SCALE V 3/8-llxl' TAMPER RESISTANT BOLT () INSULATORS SEE NOTE 2. (TYP) 4 ►9J WALL BRACKET () a d d Q a d a d d a d a a UNIVERSAL COPPER a GROUND BAR (4'x20' LOCK WASHER - P/N M10 (TYP) TWO -HOLE COMPRESSION LUG NOTES: 1. DOWN LEAD (HOME RUN) CONDUCTORS ARE M TO BE INSTALLED ON CROWN CASTLE TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. 2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. 6 GROUND BAR DETAIL SCALE: NOT TO 5CALE TO ANTENNAS COAX JUMPER (TYP. CONNE WEATHERPROOFIN (TYP. SEE NO ANTENNA TO BTS EQUIPMENT WEATHERPROOFING KIT (TYP) GROUND KIT (TYP) 16 AWG TOPPER ANTENNA ,ROUND BAR, WITH NSULATORS. BONDED )IRECTLY TO TOP OF IGHT POLE OR UTILITY 'OLE NHS, ---ilW� TO GROUND RING 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED. GROUND CABLE CONNECTION 4 SCALE: NOT TO SCALE NOTE: MINIMUM OF S/S NUT 3 THREADS TO BE (TYP) VISIBLE (TYP) S/S SPLIT 2 HOLE LONG (TYPWASHER BARREL TINNED) SOLID COPPER LUG S/S FLAT (TYP) WASHER (TYP) IN COATED SOLID —� COPPER BUS BAR S/S FLAT WASHER CHERRY INSULATOR (TYP) INSTALLED IF REQUIRED., I S/S BOLT E I I I (TYP) 7 LUG DETAIL SCALE: NOT TO SCALE GROUND BAR ` BOLT (SEE CHART) (m) ',�BURNOY TWO HOLE LUG W/ LONG BARREL (SEE CHART) BARE WIRE TO BE NO-OX AT BOTH ENDS STRANDED (GREEN INSULATED) ONLY FOR #6 AWG (SEE CHART) NOTES: 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALL HARMAM BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL ALL HA AYNAIRE ARE TO BE AS FOLLOWS: BOLT, FIAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT. MECHANICAL LUG CONNECTION SCALE: NOT TO SCALE #6 AWG MIN. FROM ANTENNA CABLE GROUND KIT GROUND BAR ON SHELTER. BRIDGE, OR ON ANTENNA TOY -TWO HOLE LOG, OR EXOTHERMIC WELD TO BE USED WITH #2 AWG BARE CONDUCTOR WIRE TO BUILDING SERVICE GROUND OR GROUND RING GROUNDWIRE INSTALLATION SCALE: NOT TO SCALE #2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUIT FROM 24' BELOW GRADE TO WITHIN 3' TO 6' OF CAD -WELD TERMINATION POINT. EXPOSED END OF THE LIQUID TIGHT CONDUIT MUST BE SEALED WITH SILICONE CAULK. CADWELD (TYP) TIE INTO EXISTING GROUND RING TRANSITIONING GROUND DETAIL SCALE: NOT TO SCALE GROUNDING SHALL BE ELIMINATEDECTRWHEN GROUND BAR IS ELECTRICALLY BONDED TO METAL TOWER SPRINT SITE NUMBER SE63XC320 BU #: 880427 SEATTLE QWEST - SEA123 29208 -18TH AVENUE, SOUTH FEDERAL WAY, WA 98003 EXISTING 85'-0" MONOPOLE ISSUED FOR I REV DATE DRWN DESCRIPTION DWQ A 6/26/17 ZTK PRELEM]NARY ZTK 0 8/9/17 CWJ CONSTRUCTION RAB Co«.e.....n 1� 8/9/2017 1 10:A ;?I AM EMT RuudA. BodoM PJL Pm6mmoml Bogio� r l- 40152 Cm Cade USA, Inc. Fim Regienmion #2Z/1 IT IS A VIOLATION OF TAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THT5 D'OCUVl---_I' SHEET NUMBER SIO -2 PARTS LIST W (SEE PAGE 3) �1 �f 24" OR 48" _ -~ STANDARD (CUT AS REQUIRED) I 1 917l32" 1 REQUIRED ROD LENGTH IS EQUAL TO THE POLE DIAMETER. THREADED ROD MAY BE CUT TO LENGTH AS REQUIRED. 4" (REF) r■NI .,... EI c: [ME ��■ 61141, (REF) ITEM QTY PART NO. PART DESCRIPTION LENGTH RING MOUNT WELDMENT UNIT WT. NET WT. 1 3 X-LWRM 68.16 204.48 2 9 G58R-48 518" x 48" THREADED ROD (HOG.) 0.55 4.94 2 9 G58R-24 518" x 24" THREADED ROD (H DG.) 0.55 4.94 3 18 A58FW 5/8" HDG A325 FLATWASHER 0.03 0.61 4 18 G58LW 518" HDG LOCKWASHER 0.03 0.47 5 18 A58NUT 518" HDG A325 HEX NUT 0.13 2.34 TOTAL WT. # 264.35 12" TO 45" DIAMETER Rl1AAlA�f11 C TOLERANCE NOTES DESCRIPTION N waYo*,NY ON DIMENSIONS, UNLESS OTHERWISE NOTEO ARE: M RINGTOLERANCES a, GA Engineering LosAthAngeles, Support Team: Los SAWED. 5HEAREDAND GAO CUT EDGES9d0 9 �i B LY ASSEMBLY ASSEMBLY SS 1-$88`7537446 Plymouth, IN ORILLEDAND GAS CUT HOLES 1*0.WO-)-NOCONING OFHOLES 12" TO45" DIAMETER POLE Selem,OR LASER CUT EDGES AND HOLES ftA 0!Q-) - NO CONING OF HOLES A valmontwomm DaDas,TX BENDS ARE t 112 DEGREE ALL OTHER UACHINING (t asw) GPD NO. DRAWN BY ENG. APPROVAL PART NO. s ALL OTHER ASSEMBLY ft A "07 4433 BMC 3/17/2009 LWRM O 3 T p REDRAWN IN INV, UPDATED TABLES &VIEWS KC8 7l2b12012 PROPRiETAWkErrE. THE DATAANOTECHNHINES00TAINEDINTHN DRYDNNEANFROPMETApYINPOWTION OFVAWONT IMDD�T OPANDODNi10FAEDATR11DEaEC11ET.AWWEOR014CL9WRE:NRHOUTTHECORSENTff GLASS SUB 81 01 DRAWING USAGE CUSTOMER CHECKED BY CEK 8124/2012 DWG. NO. LWRM m 03 REV I DESCR IPTION OF REVISIONS ,,,�r+, l CPD I BY DATE Ir A 2-318" OD PIPE, 2-718" OD PIPE or 3-112" OD PIPE, PIPE NOT INCLUDED PARTS LIST ITEM QTY PART NO. PART DESCRIPTION LENGTH 8" STAND-OFF ARM I WALL MOUNT UNIT WT. NET WT. 1 1 X-WWM01 18.12 18.12 2 4 A582112 518" x 2-112" HDG A325 HEX BOLT 2112 in 0.33 1.34 3 4 A58FW 5/8" HDG A325 FLATWASHER 0.03 0.14 4 4 G58LW 518" HDG LOCK WASHER 0.03 0.10 5 4 A88N UT &8" HDG A325 HEX NUT 0.13 0.52 6 2 X-UB1212 1/2" X 2-1/2" X 4112"X 2" GALV. U-BOLT 0.66 1.31 6 2 X-UB1300 1/2"X 3"X 5" X 2" GALV U-BOLT 0.70 1.39 6 2 X-UB1358 1/2" X 3-5/8" X 5-112" X 3" GALV U-BOLT 0.77 1.54 7 4 G12FW 1/2" H DG USS FLATWASHER 0.03 0.14 8 4 G12LW 112" HDG LOCKWASHER 0.01 0.06 9 4 G12NUT 1/2" HDG HEAVY 2H HEX NUT 0.07 0.29 TOTAL WT. # 26.06 DETAIL A TOLERANCE NOTES DESCRIPTION New YYbFk,NY TOL.ERANCER ON DIMENSIONS, UNLESS OTHERWISE NOTED ARE. S" STAND-OFF ANTENNA WALL MOUNT,ri Engineering ppriar Los AAtIona, GA pm Support Team: LasA"gh,IN A SAWED,SHEAREOANDGAS CUTEOGESftit17I�0 1-888.75&74d6 Plymouth,IN DRILLED ANO G" CUT HOLES f F 0.0S0-) -NO CONING OF HOLES SITE PRO 1 Sale m, OR LASER CUT EDGES AND HOLES ff Q 010') - NO CONING OF HOLES A valmosty, Dallas, TX SENDS ARE t 112 DEGREE ALL OTHER MACHINING (ARLOW-) CPD NO. DRAWN BY ENG. APPROVAL PART NO. j ALL OTHER ASSEMBLYftA"07 4714 RH18 3/23/2010 mm0l O $ ?ROfRMARYWOTE; CLASS SUB DRAWING USAGE CHECKEDBY DWG. NO. m s THE RANAAMTICHNNWEI CMAINEOINTHR ON kf ARE FNOFlEE AITf INFONNATION OF MUSS R IMUST11�A11000NSIOEREDATEADEIEENET. AIN USE OROISCUIUSUIESIRNOUTTNEC0FINWOF 81 O1 CUSTOMER BM C 5�1012010 �VI M O � ., A PARTS LIST UNIT WT. NET WT. ITEM QTY PART NO. PART DESCRIPTION LENGTH DOUBLE ANTENNA MOUNT 1 2 X-DAC 5.36 10.72 3 12 G12R-6 1/2" x 6" GALV. THREADED ROD 0.33 4.01 4 24 G12FW 1/2" H DG LISS FLATWASHER 0.03 0.82 5 24 G12LW 112" HOG LOCK WASHER 0.01 0.33 6 24 G12NUT 1/2" HOG HEAVY 2H HEX NUT 0.07 1.72 9 6 X-100054 CLAMPS 4" V CLAMP GALVANIZED 0.91 5.48 TOTAL WT. # 24.75 1-1/2" to 3-1/2" OD MOUNTING LEG OR ANTENNA PIPE. TOLERANCE NOTES TOLERANCES ON DIMENSIONS. UNLESS OTHERWISE NOTED ARE: SAWED, SHEARER ANO {SAS GUTEOGE8 (tQO804) DRILLED AND G"CUT HOLES (& A W" - NO CMING OF HOLES LASER CUT EDGES AND HOLES ftA 0!D') - NO CONING OF HOLES BENDS ARE t 1J2 DEGREE ALL OTHER MACHINING ft 19OW-) A I REVISEDX-DAC DESIGN 4725 RH18 9I2312010 ALL OTHERASSEMBLY (t400rj pRappWARY mom 'EV ❑ESORIPTIONOFREVISIONS I CPD BY DATE THEDAIAAND TEOAMIoUE$=WAJNEI)WTHE ORMN4APE PI PRETAffINFUMTHNOFVAU10Ni REVISION HISTORY WOUYTFMAEDCOIIII13EAEDA11WEVOMET, AMfUSE OEOIEOWSUNIEfrSICUTTHECORNENTOF �m wouml�ssrllmr�x 4•ROtIIaITED. r-i r -i r-i ADJ U: LJ LJ LJ i 13116" TABLE Locations: DESCRIPTION New York, NY DO U BLE AN TENNA Engineering I I Non Atlanta, GA CLAMP Support Team: LosAngeles,CA ASSEMBLY 1-668-763-7446 ■ ValmontIroww Plymouth, IN Sale m, OR Dallas,TX CPD NO. DRAWN BY ENG.APPROVAL PART NO. i 4725 RH18 41112010 DAC O DLASSJ SUB DRAWING USAGE CH@3KED BY DWG. NO. -n m 81 1 01 CUSTOMER BMC 8/15/2013 DAC 1