12-101542 (2)Your world. Delivered. FEDERAL WAY DECA FUf PROJECT INFORMATION PROJECT DESCRIPTION: AT&T PROPOSES TO MODIFY EXISTING UNSTAFFED TELECOMMUNICATIONS FACILITY BY REMOVING AN EXISTING ANTENNA MOUNT AND RELOCATING (3) EXISTING ANTENNAS TO A NEW ANTENNA MOUNT EXTENSION WITH THE ADDITION OF (3) LTE PANEL ANTENNAS, (3) TMA'S. PLUS THE ADDITION OF (6) RRH UNITS, (6) DIPLEXERS MOUNTED TO A NEW H-FRAME ALONG WITH (1) LTE EQUIPMENT RACK MOUNTED WITHIN EXISTING AT&T EQUIPMENT ROOM LOCATED BETWEEN STORAGE DOORS #152 AND #149. APPLICANT: AT&T MOBILITY RTC BUILDING 3 16221 NE 72ND WAY REDMOND, WA 98052 CODE INFORMATION: ZONING CLASSIFICATION: BN BUILDING CODE: 2009 IBC CONSTRUCTION TYPE: IIB OCCUPANCY: U, S-2 JURISDICTION: CITY OF FEDERAL WAY CURRENT USE: UNMANNED TELECOM FACILITY PROPOSED USE: UNMANNED TELECOM FACILITY SITE LOCATION: (BASED ON NAD 83 LATITUDE: 47° 19' 25.5" N LONGITUDE: -122° 21' 37.2" W TOP OF STRUCTURE AGL: 53'-6" BASE OF STRUCTURE AMSL: 276'-0" PARCEL NUMBER (Si: 1221039088, 1221039087 GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED. 2. TRAFFIC IS UNAFFECTED. PROPERTY OWNER: FEDERAL WAY SELF STORAGE INVESTORS, LLC 14100 SE 36TH ST, STE 200 BELLEVUE, WA 98006 TOWER OWNER: PUGET SOUND ENERGY 355 110TH AVE NE EST-06E BELLEVUE, WA 98004 CONTACT: TIM GASSER PH: (425) 456-2776 TEAM LEAD: WESTOWER COMMUNICATIONS 7525 SE 24TH STREET,, -SUITE 500 MERCER ISLAND, WA-98040 CONTACT: KEITH ELWELL PH: (425) 753-3458 SITE ACQUISITION: PACIFIC TELECOM SERVICES, LLC 111 SOUTH JACKSON STREET 2ND FLOOR SEATTLE, WA 98104 CONTACT: BECKY TODD PH: (206) 342-6388 PERMITTING: PACIFIC TELECOM SERVICES, LLC 111 SOUTH JACKSON STREET, 2ND FLOOR SEATTLE, WA 98104 CONTACT: SUNNY AUSINK PH: (206) 342-6390 CONSTRUCTION MANAGER: WESTOWER COMMUNICATIONS 7525 SE 24TH STREET, SUITE 500 MERCER ISLAND, WA 98040 CONTACT- KEITH ELWELL PH: (425) 753-3458 RF ENGINEER: WESTOWER COMMUNICATIONS 7525 SE 24TH STREET, SUITE 500 MERCER ISLAND, WA 98040 CONTACT: MICHELLE BRAASCH PROJECT TEAM PROJECT ARCHITECT PROJECT CONSULTANT PROJECT CONSULTANT RICHARD B. HALL, AIA PACIFIC TELECOM SERVICES, LLC WESTOWER COMMUNICATIONS PACIFIC TELECOM SERVICES, LLC 111 SOUTH JACKSON STREET, 2ND FLOOR 7525 SE 24TH STREET, SUITE 500 111 SOUTH JACKSON STREET, 2ND FLOOR SEATTLE, WA 98104 MERCER ISLAND, WA 98040 SEATTLE, WA 98104 CONTACT: KATIE KENNEY PH: (206) 819-4727 CONTACT: CHRIS WICKLANDER PH: (206) 909-9454 PH: (425) 478-7988 EMAIL: CWICKLANDERQPTSWA.COM SS66 31031 21ST PLACE SW FEDERAL WAY, WA 98023 VICINITY MAP DRIVING DIRECTIONS START FROM REGIONAL OFFICE: DEPART NE 72ND WAY TOWARD 164TH AVE NE 475 FT TURN RIGHT ONTO 164TH AVE NE, AND THEN IMMEDIATELY TURN RIGHT ONTO BEAR CREEK PKWY 0.4 MI TURN LEFT ONTO LEARY WAY NE 0.1 MI ROAD NAME CHANGES TO NE LEARY WAY 0.2 MI TAKE RAMP RIGHT FOR WA-520 WEST TOWARD SEATTLE 5.0 MI TAKE RAMP RIGHT FOR 1-405 SOUTH TOWARD RENTON 15.0 MI ROAD NAME CHANGES TO WA-518 WEST 0.1 MI TAKE RAMP RIGHT FOR 1-5 SOUTH TOWARDPORTLAND 7.6 MI AT EXIT 147, TAKE RAMP RIGHT AND FOLLOW SIGNS FOR S. 272ND ST. 0.3 MI TURN RIGHT ONTO S 272ND ST 0.6 MI TURN LEFT ONTO WA-99 / PACIFIC HWY S 0.5 MI KEEP STRAIGHT ONTO WA-99 / WA-509 / PACIFIC HWY S 1.1 MI TURN RIGHT ONTO WA-509 / S DASH POINT RD 2.8 MI TURN RIGHT ONTO 21 ST WAY SW 0.2 MI ARRIVE AT 31031 21ST WAY SW, FEDERAL WAY, WA 98023 APPROVAL DATE SIGNATURE APPROVAL DATE SIGNATURE RF ENGINEER: LANDLORD: RF MANAGER: SITE ACQUISITION: OPPS MANAGER: ZONING AGENT: CONSTR MANAGER: PROJECT MANAGER: NSB MANAGER: CONSTR MANAGER: TRANSPORT: EQUIP ENGINEER: COMPLIANCE: REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE O I HER I HAN I HAI WHICH RLLAI L5 I U CARRILR `SERVICES 15 `S I NIC I LY PROHIt3I 1 LU. DRAWING INDEX SHEET IDESCRIPTION T-1 TITLE SHEET G-1 GENERAL NOTES & SYMBOLS A-1 SITE PLAN A-2 EXISTING EQUIPMENT & ANTENNA PLAN A-3 PROPOSED EQUIPMENT & ANTENNA PLAN A-4 EXISTING & PROPOSED SOUTHEAST ELEVATION A-5 CONSTRUCTION DETAILS A-6 CONSTRUCTION DETAILS RF-1 ANTENNA CONFIGURATIONS RF-2 RF & EQUIPMENT DETAILS E-1 SCHEMATIC GROUNDING PLAN E-2 GROUNDING DETAILS ABBREVIATIONS PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. FINAL CONSTR.LICTION DRAWINGS 0+04-12 LEGAL DESCRIPTION PARCEL A: THAT PORTION OF THE WEST 135 FEET OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST, W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO 980 (J.M. ERCHINGER ROAD, AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310) AND NORTH OF THE FOLLOWING DESCRIBED LINE; BEGINNING AT A POINT ON THE EAST LINE OF SAID WEST 135 FEET WHICH IS 80 FEET SOUTH OF THE SOUTHWESTERLY MARGIN OF SAID COUNTY ROAD; THENCE WEST AT RIGHT ANGLES TO SAID EAST LINE 135 FEET TO THE EST LINE OF SAID SOUTHEAST QUARTER OF THE NORTHEAST QUARTER AND THE TERMINUS OF THE LINE HEREIN DESCRIBED. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. PARCEL B: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY: THE WEST 165 FEET OF THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST, W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO. 980 AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310; EXCEPT THAT PORTION LYING NORTH OF A LINE RUNNING WEST AT RIGHT ANGLES FROM A POINT ON THE EAST LINE OF THE WEST 135 FEET OF SAID SUBDIVISION WHICH IS 80 FEET SOUTH OF THE SOUTHWESTERLY MARGIN OF SAID COUNTY ROAD NO. 980, TO THE WEST LINE OF SAID SOUTHEAST QUARTER OF THE NORTHEAST QUARTER. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. PARCEL C: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY: THE EAST 135 FEET OF THE WEST 300 FEET OF THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST, W.M., LYING SOUTHEASTERLY OF COUNTY ROAD NO. 980 (ERCHINGER ROAD, 21ST PLACE SOUTHWEST AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310). SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.] PARCEL D: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIED PROPERTY: THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO. 980 (21ST AVENUE SOUTHWEST AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310;) EXCEPT THE WESTERLY 300 FEET THEREOF; SITUATED IN THE COUNTY OF KING, SATED OF WASHINGTON A/C AIR CONDITIONING HORZ HORIZONTAL PLYWD PLYWOOD AGL ABOVE GROUND LEVEL HR HOUR PROJ PROJECT APPROX APPROXIMATELY HT HEIGHT PROP PROPERTY HVAC HEATING PT PRESSURE TREATED BLDG BUILDING VENTILATION REQ REQUIRED BLK BLOCKING AIR CONDITIONING RM ROOM SHT SHEET CLG CEILING ID INSIDE DIAMETER SIM SIMILAR -, CLR CLEAR IN INCH SPEC SPECIFICATION CONC CONCRETE INFO INFORMATION SF SQUARE FOOT CONST CONSTRUCTION INSUL INSULATION SS STAINLESS STEEL CONT CONTINUOUS INT INTERIOR STL STEEL IBC INTERNATIONAL STRUCT STRUCTURAL � DBL DOUBLE BUILDING CODE STD STUD - DIA DIAG DIAMETER DIAGONAL LBS POUNDS SUSP SUSPENDED DN DOWN MAX MAXIMUM THRU THROUGH DET DWG DETAIL DRAWING MECH MTL MECHANICAL METAL TNNG TYP TINNED TYPICAL - - MFR MANUFACTURE EA EACH MGR MANAGER UNO UNLESS NOTED OTHERWISE ELEV ELEVATION MIN MINIMUM ELEC ELECTRICAL MISC MISCELLANEOUS VERT VERTICAL EQ EQUAL RO ROUGH OPENING VIF VERIFY IN FIELD EQUIP EQUIPMENT EXT EXTERIOR NA NOT APPLICABLE W/ WITH NIC NOT IN CONTRACT W�O WITHOUT FIN FINISH NTS NOT TO SCALE WP WATER PROOF FLUOR FLOURESCENT FLR FLOOR OC ON CENTER FT FOOT OD OUTSIDE DIAMETER RECEIVED GA GAUGE APR U 6 201z GALV GALVANIZED GC GENERAL CONTRACTOR GRND GROUND CITY OF FEDERAL WAY GYP BD GYPSUM WALL BOARD CDS Dat&t Your world. Delivered. PACIFIC TELECOM SERVICES, LLC 8828 REGISTERED ARCHITT�C- � C CH TATE D B. HA F WASHIN N EXPIRATION DATE OF THE LICENSE: 08/20113 F� � N U) O 00 w n- o� U) N < O w Q w O w w w REVISIONS NO. DATE I DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE TITLE SHEET SHEET NUMBER T-1 GENERAL NOTES: 1. THE CONTRACTOR SHALL NOTIFY TOWER NETWORK CARRIER OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES AS THEY MAY BE DISCOVERED IN PLANS, DOCUMENTS, NOTES, OR SPECIFICATIONS PRIOR TO STARTING CONSTRUCTION INCLUDING, BUT NOT LIMITED BY, DEMOLITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY ERROR, OMISSION, OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER. 2. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. CONTRACTORS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR HAVING BEEN AWARDED THIS PROJECT SHALL VISIT THE CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT DOCUMENTS TO VERIFY FIELD CONDITIONS AND CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN WRITING. 3. FOR COLLOCATION SITES: CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID WALK. 4. NOT USED 5. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK. CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. THE BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING) THE ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S PROPOSAL. IN THE EVENT OF DISCREPANCIES THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. 6. DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCE. TOWER NETWORK CARRIER IS NOT RESPONSIBLE FOR ANY ERRORS RESULTING FROM THIS PRACTICE WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS. 7. OWNER, CONTRACTOR, AND TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER SHALL MEET JOINTLY TO VERIFY ALL DRAWINGS AND SPECIFICATIONS PRIOR TO THE START OF CONSTRUCTION. 8. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. 9. THE CONTRACTOR SHALL PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. 10. THE CONTRACTOR SHALL PROVIDE TOWER NETWORK CARRIER PROPER INSURANCE CERTIFICATES NAMING TOWER NETWORK CARRIER AS ADDITIONAL INSURED, AND TOWER NETWORK CARRIER PROOF OF LICENSE(S) AND PE & PD INSURANCE. 11. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. 13. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES BEARING ON THE PERFORMANCE OF THE WORK. 14. NOT USED 15. A COPY OF GOVERNING AGENCY IS APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY, AND BY LAW, SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES. THE ORIGINAL PERMIT SET PLANS ARE NOT TO BE USED BY THE WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS GOVERNING AGENCY APPROVED PLANS. THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS, IN GOOD CONDITION, COMPLETE WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES UNDER THE DIRECT CARE OF THE SUPERINTENDENT. THE CONTRACTOR SHALL SUPPLY TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER. WITH A COPY OF ALL REVISIONS, ADDENDA, AND/OR CHANGE ORDERS AT THE CONCLUSION OF THE WORK AS A PART OF THE AS -BUILT DRAWING RECORDS. 16. THE STRUCTURAL COMPONENTS OF ADJACENT CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED BY THIS CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. 17. THE CONTRACTOR SHALL STUDY THE STRUCTURAL, ELECTRICAL, MECHANICAL, AND PLUMBING PLANS AND CROSS CHECK THEIR DETAILS, NOTES, DIMENSIONS, AND ALL REQUIREMENTS PRIOR TO THE START OF ANY WORK. 18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE PROJECT AND SITE WHILE THE WORK IS IN PROGRESS UNTIL THE JOB IS COMPLETE. 19. THE CONTRACTOR HAS THE RESPONSIBILITY OF LOCATING ALL EXISTING UTILITIES WHETHER OR NOT SHOWN ON THE PLANS, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR, OR SUBCONTRACTOR AS SPECIFIED IN THE AGREEMENT BETWEEN SUBCONTRACTOR AND CONTRACTOR, SHALL BEAR THE EXPENSES OF REPAIR AND/OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGE BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. 20. THE REFERENCES ON THE DRAWINGS ARE FOR CONVENIENCE ONLY AND SHALL NOT LIMIT THE APPLICATION OF ANY DRAWING OR DETAIL. 21. ALL DIMENSIONS ON THE PLANS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE (U.N.O.). 22. ALL EXISTING CONSTRUCTION, EQUIPMENT, AND FINISHES NOTED TO BE REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL BE REMOVED FROM THE SITE WITH THE FOLLOWING EXCEPTIONS: A. PROPERTY NOTED TO BE RETURNED TO THE OWNER. B. PROPERTY NOTED TO BE REMOVED BY THE OWNER. 23. THE GOVERNING AGENCIES, CODE AUTHORITIES, AND BUILDING INSPECTORS SHALL PROVIDE THE MINIMUM STANDARDS FOR CONSTRUCTION TECHNIQUES, MATERIALS, AND FINISHES USED THROUGHOUT THE PROJECT. TRADE STANDARDS AND/OR PUBLISHED MANUFACTURERS SPECIFICATIONS MEETING OR EXCEEDING DESIGN REQUIREMENTS SHALL BE USED FOR INSTALLATION. 24. WHEN REQUIRED STORAGE OF MATERIALS OCCURS, THEY SHALL BE EVENLY DISTRIBUTED OVER ROUGH FRAMED FLOORS OR ROOFS SO AS NOT TO EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE. TEMPORARY SHORING AND/OR BRACING IS TO BE PROVIDED WHERE THE STRUCTURE HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT. 25. PRIOR TO THE POURING OF ANY NEW SLAB OVER AN EXISTING SLAB THE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, CHASES, AND EQUIPMENT WHICH ARE TO BE IMPLEMENTED INTO THE NEW WORK. ALL ITEMS DESIGNATED TO BE ABANDONED SHALL BE NOTED AND DISCUSSED WITH THE OWNER AND TOWER NETWORK CARRIER CONSTRUCTION PROJECT MANAGER AS PART OF THE AS -BUILT DRAWING PACKAGE. 26. SEAL ALL PENETRATIONS THROUGH FIRE -RATED AREAS WITH U.L. LISTED OR FIRE MARSHALL APPROVED MATERIALS IF APPLICABLE TO THIS FACILITY AND OR PROJECT SITE. 27. BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE NOTIFIED PRIOR TO ANY GRADING, CONSTRUCTION, AND ANY OTHER PROJECT EFFORT AS MANDATED BY THE GOVERNING AGENCY. 28. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. 29. THE PROJECT, WHEN COMPLETED, SHALL COMPLY WITH LOCAL SECURITY CODES AND TITLE-24 ENERGY CONSERVATION REQUIREMENTS. (TITLE-24 WHEN APPLICABLE) 30. ALL GLASS AND GLAZING IS TO COMPLY WITH CHAPTER 54 OF THE U.S. CONSUMER SAFETY COMMISSION - SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (42 FR 1428, CFR PART 1201) AND LOCAL SECURITY REQUIREMENTS. 31. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS EASEMENTS PAVING CURB ING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY, 32. CONTRACTOR SHALL KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. CONTRACTOR SHALL REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. 33. NEW CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL MATCH IN FORM, TEXTURE, FINISH, AND IN MATERIALS EXCEPT AS NOTED IN THE PLANS AND SPECIFICATIONS. 34. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BACKING, BLOCKING, AND/OR SLEEVES REQUIRED FOR THE INSTALLATION OF FIXTURES, MECHANICAL EQUIPMENT, PLUMBING, HARDWARE, AND FINISH ITEMS TO INSURE A PROPER AND COMPLETE JOB. 35. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A PROJECT LEVEL, STRAIGHT, AND TRUE ACCORDING TO THE PLANS. THE CONTRACTOR SHALL COMPARE THE LINES AND LEVELS OF THE EXISTING CONDITIONS WITH THOSE SHOWN ON THE PLANS PRIOR TO THE START OF ANY CONSTRUCTION. TOWER NETWORK CARRIER SHALL BE NOTIFIED OF ANY ERRORS, OMISSIONS, OR INCONSISTENCIES PRIOR TO ANY CONSTRUCTION. 36. THE CONTRACTOR IS TO PROVIDE PROTECTION FOR ADJOINING PROPERTIES FROM PHYSICAL HARM, NOISE, DUST, DIRT, AND FIRE AS REQUIRED BY THE GOVERNING AGENCIES. 37. WHERE SPECIFIED, MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AND/OR REVISIONS AVAILABLE AS REQUIRED BY THE GOVERNING AGENCY RESPONSIBLE FOR RECORDING THE RESULTS. 38. THE CONTRACTOR IS RESPONSIBLE FOR THE STORAGE OF ALL MATERIALS AND SHALL NOT DO SO ON PUBLIC PROPERTY WITHOUT A PERMIT TO DO SO FROM THE GOVERNING AGENCIES FOR THIS PURPOSE. 39. GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY SHOWN OTHERWISE. 40. TRADES INVOLVED IN THE PROJECT SHALL BE RESPONSIBLE FOR THEIR OWN CUTTING, FITTING, PATCHING, ETC., SO AS TO BE RECEIVED PROPERLY BY THE WORK OF OTHER TRADES. 41. ALL DEBRIS AND REFUSE IS TO BE REMOVED FROM THE PROJECT PREMISES AND SHALL BE LEFT IN A CLEAN (BROOM FINISH) CONDITION AT ALL TIMES BY EACH TRADE AS THEY PERFORM THEIR OWN PORTION OF THE WORK. 42. TOWER NETWORK CARRIER DOES NOT GUARANTEE ANY PRODUCTS, FIXTURES, AND/OR ANY EQUIPMENT NAMED BY A TRADE OR MANUFACTURER. GUARANTEE OR WARRANTY THAT MAY BE IN EFFECT IS DONE SO THROUGH THE COMPANY OR MANUFACTURER PROVIDING THE PRODUCT, FIXTURE, AND/OR EQUIPMENT ONLY: UNLESS SPECIFIC RESPONSIBILITY IS ALSO PROVIDED BY THE CONTRACTOR/SUBCONTRACTOR IN WRITTEN FORM. 43. CAUTION! CALL BEFORE YOU DIG! BURIED UTILITIES EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE ONE -CALL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. 1-800-227-2600. 44. CONTRACTOR TO REPLACE AND/OR REROUTE ANY EXISTING UNDERGROUND UTILITIES ENCOUNTERED DURING TRENCHING AND GENERAL CONSTRUCTION. 45. WHEN APPLICABLE, CONTRACTOR IS RESPONSIBLE TO CALL, COORDINATE AND MAKE ARRANGEMENTS FOR ROW AND/OR PRIVATE PROPERTY LOCATE MODIFICATION CONSTRUCTION; BASED ON SPECIFIC SITE REQUIREMENTS. 46. SEE CIVIL DRAWINGS FOR ADDITIONAL SITE INFORMATION. 47. CONTRACTORS TO DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS AND SUBMIT TO TOWER NETWORK CARRIER ALONG WITH REDLINED CONSTRUCTION SET. 48. CONTRACTOR SHALL DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP (REDLINING) THE APPROVED CONSTRUCTION SET AND SUBMITTING THE REDLINED ALONG WITH PHOTOGRAPHS PER NETWORK CARRIER REQUIREMENTS. 49. GENERAL CONTRACTOR IS TO COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. CONTRACTOR TO REPORT POWER INSTALLATION COORDINATION SOLUTION(S) TO NETWORK CARRIER REPRESENTATIVE, PROJECT CONSTRUCTION MANAGER AND ARCHITECT. 50. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY TOWER NETWORK CARRIER CONSTRUCTION MANAGER. 51. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR, AND/OR IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE PROJECT IS COMPETE AND ACCEPTED UNDER THIS CONTRACT; UNLESS NOTED OTHERWISE IN THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. (EXCEPTION) THE ROOFING SUBCONTRACTOR SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE GENERAL CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. 52. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. 53. THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS AND/OR FEES WITH RESPECT TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BY THE OWNER OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT AND MAKE FINAL PAYMENT FOR SAID DOCUMENT. 54. NOT USED 55. TOWER NETWORK CARRIER WILL REVIEW AND APPROVE SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT. TOWER NETWORK CARRIER PROJECT APPROVAL OF A SEPARATE ITEM SHALL NOT INCLUDE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS. 56. ALL ANTENNAS MOUNTED ON ROOF SUPPORT FRAMES TO BE PROVIDED BY TOWER NETWORK CARRIER COMMUNICATIONS. 57. CONTRACTOR TO PROVIDE TRENCH AS REQUIRED TO INSTALL BOTH ELECTRICAL AND TELEPHONE UNDERGROUND CONDUITS (#40 PVC) PER S.C.E. WORKORDER. BACKFILL WITH CLEAN SAND AND COMPACT TO THE SATISFACTION OF THE DISTRICTS INSPECTOR. REPLACE FINISH GRADE WITH MATCHING MATERIALS (GRASS, ASPHALT, CONCRETE, ETC.) 58. CONTRACTOR TO PROVIDE HEAVY STEEL PLATES AT OPEN TRENCHES FOR SAFETY AND TO PROTECT EXISTING GROUND SURFACES FROM HEAVY EQUIPMENT UTILIZED DURING CONSTRUCTION. 59. CONTRACTOR TO PATCH AND REPAIR ALL GROUND SURFACES WITHIN THE CONSTRUCTION AREA AS NECESSARY TO PROVIDE A UNIFORM SURFACE AND MAINTAIN EXISTING SURFACE DRAINAGE SLOPES. 60. CONTRACTOR TO REPLACE LANDSCAPE VEGETATION THAT WAS DAMAGED DUE TO CONSTRUCTION, AND TO MODIFY REMAINING IRRIGATION LINES TO OPERATING CONDITION, PROVIDING FULL COVERAGE TO IMPACTED AREAS. 61. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE PENETRATION OF EXISTING ROOFING MATERIALS OCCUR, THE GENERAL CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER AND BUILDING ROOFING CONTRACTOR OF RECORD FOR INSTALLATION, PATCH, REPAIR OR ANY AUGMENTATION TO THE ROOF, AND HAVE THE WORK GUARANTEED UNDER THE ROOFING CONTRACTOR'S WARRANTY FOR MOISTURE PENETRATION OR AND OTHER FUTURE BREACH OF ROOFING INTEGRITY. 62. IN THE CASE OF ROOFTOP SOLUTIONS WITH THE INSTALLATION OF ANTENNAS WITHIN CONCEALED (SHROUDED) SUPPORT FRAMES OR TRIPODS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE FRP DESIGNER/FABRICATOR TO ENSURE THAT THE FINAL FRP SHROUD IS SIMULATING (IN APPEARANCE) DESIGNATED EXISTING EXTERIOR BUILDING FACADE MATERIALS, TEXTURES, AND COLORS. THE CONTRACTOR SHALL FURTHERMORE ENSURE THE USE OF COUNTERSUNK FASTENERS IN ALL FRP CONSTRUCTION. WHEN PHOTOSIMULATIONS ARE PROVIDED, THE CONTRACTOR SHALL ENSURE THAT FINAL CONSTRUCTION REPRESENTS WHAT IS INDICATED IN PHOTOSIMULATION. SHOP DRAWINGS SHALL BE PROVIDED TO THE GENERAL CONTRACTOR, CONSTRUCTION COORDINATOR, AND ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION. 63. IN THE CASE OF ROOFTOP SOLUTIONS FOR EQUIPMENT AND/OR ANTENNA FRAMES WHERE ANCHORING TO A CONCRETE ROOF SLAB IS REQUIRED, CONTRACTORS SHALL CONFIRM (PRIOR TO SUBMITTING BID) WITH CONSULTING CONSTRUCTION COORDINATOR AND ARCHITECT THE PRESENCE OF POST TENSION TENDONS WITHIN THE ROOF SLAB - RESULTING FROM AN UNDOCUMENTED DESIGN CHANGE IN THE EXISTING BUILDING "AS -BUILT DRAWING SET" - HAVING INDICATED AN ORIGINAL DESIGN SOLUTION OF REINFORCED CONCRETE W/ EMBEDDED STEEL REBAR. IN THE EVENT POST TENSION SLAB SOLUTION IS PRESENT, CONTRACTOR SHALL INCLUDE PROVISIONS FOR X-RAY PROCEDURES (INCLUDED IN BID) FOR ALL PENETRATION AREAS WHERE ANCHORING OCCURS. 64. GENERAL & SUB CONTRACTORS SHALL USE STAINLESS STEEL METAL LOCKING TIES FOR ALL CABLE TRAY TIE DOWNS AND ALL OTHER GENERAL TIE DOWNS (WHERE APPLICABLE). PLASTIC ZIP TIES SHALL NOT BE PERMITTED FOR USE ON TOWER NETWORK CARRIER PROJECTS. RECOMMENDED MANUFACTURE SHALL BE: PANDUIT CORP. METAL LOCKING TIES MODEL NO. MLT4S-CP UNDER SERIES-304 (OR EQUAL). PANDUIT PRODUCT DISTRIBUTED BY TRIARC. 65. NOT USED. SYMBOLS: x GRID REFERENCE DETAIL REFERENCE ELEVATION REFERENCE -:------------..... -- SECTION REFERENCE _ ......................__.... CENTERLINE - PROPERTY/LEASE LINE - - MATCH LINE `.._.._._....__........._....______ WORK POINT Cll:Z�1�1�DZK�P►��I�I� • ------- - TELEPHONE CONDUIT -- ELECTRICAL CONDUIT ___.......... COAXIAL CABLE OVERHEAD SERVICE CONDUCTORS GROUT OR PLASTER -_ BRICK 'fflll0/OIf (E) MASONRY ... ................................. y ..... . CONCRETE EARTH Tt=Tr=r�n Sri 1 GRAVEL PLYWOOD ? .,2=2 SAND WOOD CONTINUOUS WOOD BLOCKING STEEL '::�T/�!'TllrTll ) NEW EXISTING - NEW ANTENNA EXISTING ANTENNA GROUND ROD GROUND BUS BAR MECHANICAL GRND. CONN. CADWELD GROUND ACCESS WELL ELECTRIC BOX TELEPHONE BOX LIGHT POLE FND. MONUMENT SPOT ELEVATION SET POINT REVISION at&t Your world. Delivered. PACIFIC TELECOM SERVICES, LLC 882 REGISTERED RC T CT j ICHARD B. HALL. STATE bF WASHINGTO,' EXPIRATION DATE OF THE LICENSE: 08/20/13 � N cf) LLl O 00 J� cn N < n O J Q W r� 0 W LL. REVISIONS NO. DATE DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE GENERAL NOTES & SYMBOLS SHEET NUMBER G-1 I Ht INI-UKMAI IUN UUIN IAINtU IN r11J �)t I Ur UUIVJ I KUL I IUIV UUUUIVILIV 1 3 IJ r r1\Ur'FCIL I/\m T Of I14H1 UFCL. NIV I UDC- UFC UIJULUJUFCL U I nLF\ n 11V I n/-11 VVnIUn FCLL-\I LJ I U Uh(\RILFR JCfCVII.CJ IJ 3 1 RIU I Li r'KUrlInI I LU. LEGEND NOTE: PROPOSED AT&T LTE ANTENNAS/MOUNT — — SUBJECT BOUNDARY LINE AND MOUNTING HARDWARE TO BE PAINTED i TO MATCH EXISTING SITE CONDITIONS. — RIGHT-OF-WAY CENTERLINE i RIGHT—OF—WAY LINE I I I — — — — — — — — — — — — — ADJACENT BOUNDARY LINE SECTIONAL BREAKDOWN LINE OHP OHP OVERHEAD POWER LINE UV;\ .............. BURIED POWER LINE BURIED GAS LINE OHT OHT OVERHEAD TELEPHONE LINE ...... J G 7 - -- BURIED TELEPHONE LINE W W W W BURIED WATER LINE SS —SS -SS— BURIED SANITARY SEWER SD —SD —SD- BURIED STORM DRAIN DITCH LINE/FLOW LINE AT&T PROPOSES TO MODIFY EXISTING UNSTAFFED TELECOMMUNICATIONS FACILITY BY REMOVING AN EXISTING ANTENNA ROCK RETAINING WALL MOUNT AND RELOCATING (3) EXISTING ANTENNAS TO A NEW ANTENNA ' MOUNT EXTENSION . . . . VEGETATION LINE WITH THE ADDITION OF (3) LTE PANEL ANTENNAS (3) TMA'S. PLUS THE ADDITION OF (6) RRH UNITS, (6) DIPLEXERS — x — x — x — x — x — CHAIN LINK FENCE r F�� MOUNTED TO A NEW H-FRAME ALONG WITH (1) LTE EQUIPMENT RACK j • MOUNTED WITHIN EXISTING AT&T EQUIPMENT ROOM LOCATED BETWEEN - -' - WOOD FENCE B, STORAGE DOORS #152 AND #149 — x — x — x — x — x — BARBED WIRE/WIRE FENCE i S S7. TRANSFORMER FIRE HYDRANT 0 LIGHT STANDARD N GATE VALVE POWER VAULT ® WATER METER \\ `• , ® UTILITY BOX � FIRE STAND PIPE \ UTILITY POLE ❑ CATCH BASIN, TYPE E POLE GUY WIRE@ CATCH BASIN, TYPE II Ka GAS VALVE SIGN EXISTING AT&T VEHICULAR ACCESS AND PARKING PARCEL NUMBER: ❑O GAS METER 0BOLLARD " ..s\. \ VIA EXISTING ASPHALT DRIVE (CALL AHEAD TO 1221039088, 1221039087 1 COORDINATE W/ STORAGE FACILITY OWNER) TELEPHONE VAULT MAIL BOX A-4 \ \ 2 ° TELEPHONE RISER 234.21 SPOT ELEVATION LEGAL DESCRIPTION: A 4 EXISTING BUILDING ACCESS DOOR _ \\ PARCEL A: EXISTING ° THAT PORTION OF THE ' WEST 135 FEET OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, STORAGE TOWNSHIP 21 NORTH, � RANGE 3 EAST, W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO 980 J.M. ERCHINGER ( ' UNITS � ROAD, AS CONVEYED BY DEED RECORDED UNDER RECORDING 1 1.� NO. 980310) AND NORTH OF THE FOLLOWING ". a a \, DESCRIBED LINE; TAX LOT N 0. 1221039088 TAX LOT NO. 1221039087 TY LINE N88'55'44"W 817.30' TAX LOT N0. 1221039025 BEGINNING AT A POINT ON THE EAST LINE OF SAID WEST 135 FEET WHICH IS 80 FEET SOUTH OF THE SOUTHWESTERLY MARGIN OF SAID COUNTY ROAD; THENCE WEST AT RIGHT ANGLES TO SAID EAST LINE 135 FEET TO THE EST LINE OF SAID SOUTHEAST QUARTER OF THE NORTHEAST QUARTER AND THE TERMINUS OF THE LINE HEREIN DESCRIBED. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. PARCEL B: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY: THE WEST 165 FEET OF THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST, W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO. 980 AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310; EXCEPT THAT PORTION LYING NORTH OF A LINE RUNNING WEST AT RIGHT ANGLES FROM A POINT ON THE EAST LINE OF THE WEST 135 FEET OF SAID SUBDIVISION WHICH IS 80 FEET SOUTH OF THE SOUTHWESTERLY MARGIN OF SAID COUNTY ROAD NO. 980, TO THE WEST LINE OF SAID SOUTHEAST QUARTER OF THE NORTHEAST QUARTER. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. PARCEL C: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIBED PROPERTY: THE EAST 135 FEET OF THE WEST 300 FEET OF THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST, W.M., LYING SOUTHEASTERLY OF COUNTY ROAD NO. 980 (ERCHINGER ROAD, 21 ST PLACE SOUTHWEST AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310). SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON.] PARCEL D: AN UNDIVIDED HALF INTEREST IN THE FOLLOWING DESCRIED PROPERTY: THAT PORTION OF THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 21 NORTH, RANGE 3 EAST W.M., LYING SOUTHWESTERLY OF COUNTY ROAD NO. 980 (21 ST AVENUE SOUTHWEST AS CONVEYED BY DEED RECORDED UNDER RECORDING NO. 980310;) EXCEPT THE WESTERLY 300 FEET THEREOF; SITUATED IN THE COUNTY OF KING, SATED OF WASHINGTON VICINITY MAP North to be determined by site survey (if possible). 24"x36" SCALE: 1 " = 40'-0" SITE PLAN 1 1 1 "x 17" SCALE: 1 " = 80'-0" 40 20 0 40' . rn1� nr n�11 �nnnlrn at&t Your world. Delivered. PACIFIC TELECOM SERVICES, LLC 8828- 'REGISTERED fARCHI CT i 1` 1 ICH : RID B. HA ATE OF WASHINGT� ' L EXPIRATION DATE OF THE LICENSE: 08/20/13 F� N (n WI O 00 Q N O J Q W � W W F� REVISIONS NO. DATE DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE SITE PLAN SHEET NUMBER A-1 I 11 IIVr VrCIVIHIIVIV i.vIVIHIIVCV IIV II-IIJ JLI _IF I.iVIVJII\VIiIIVIV VVVVIVILIVIJ IJ rl\Vrl\IL li11\I UI IVfII VI\L. /'"11V1 I YYI IIVII 1\LLfII LJ IV V 1\1\I LI\ JLI\VIVLJ IJ JII\IVILI I-f\1JF_lIDIICV. EXISTING AT&T (8) VERTICAL CONDUITS Al EXISTING UTILITY P' EXISTING AT&T PAD Mc EXISTING AT&T FIBER EXISTING AT&T EQUIPN EXISTING AT&T FIBER EXISTING AT&T BBU C EXISTING AT&T PPC C EXISTING AT&T A/C C EXISTING AT&T UMTS EXISTING 3'—O" WIDE HOLLOW METAL DOOR EXISTING AT&T TELCO EXISTING (2) AC UNIT' EXISTING AT&T DISTRIE ]STING OVERHEAD POWER LINE ISTING EDGE OF SIDEWALK (STING AT&T PANEL ANTENNA TOTAL, (1) PER SECTOR TO REMOVED AND RELOCATED ISTING 53'-6" HIGH LITY POLE ISTING AT&T ANTENNA MOUNT BE REMOVED ISTING OVERHEAD TELCO LINE STING OVERHEAD POWER LINE STING AT&T UNDERGROUND COAXIAL BLE CONDUITS TO ANTENNAS STING AT&T DOG HOUSE STING AT&T UTILITY RACK STING COAX CABLE RTS (3) TOTAL STING TREE STING AT&T GPS ANTENNA UNTED AT EXISTING H—FRAME STING BUILDING STING AT&T (2) GSM CABINETS DOORS REMOVED 24"x36" SCALE: 3/4" = 1'-0" 1 1 "x17" SCALE: 3/8" = 1'-0" 1' 6" 0" 1' EXISTING EQUIPMENT &ANTENNA PLAN 1 at&t Your world. Delivered. PACIFIC TELECOM SERVICES, LLC 8828 �2EGISTERED i ARCHITECT- ki RD B. HALL `STATE 0f WASHINGTON s EXPIRATION DATE OF THE LICENSE: 08/20/13 CN O 00 w 0-) U 07 < N J Q ry O LLl h� r� w LL REVISIONS NO. DATE DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE EXISTING EQUIPMENT & ANTENNA PLAN SHEET NUMBER A-2 FHE INFORMATION CONIAINtU IN I lt5 5LI Ur UUIN� NUUIlulu UUUUIVIIENIJ I� MNUI-'NILIANT bT IN/AIUNL. HINT U-)L UN UIJI.LUJUNl UInlr< Irl/-\IN inHi wrn'-,n mr-LfiIL3 1v l,/1FWME-F\ JGFCVII,CJ 13 JIFCIUILt r MUnIC711LU. 5 PROPOSED AT&T LTE ANTENNA F- (1 PER SECTOR, 3 TOTAL, EXISTING AT&T (8) VERTIC AT EXISTING UTILITY POLE EXISTING AT&T PAD MOUN EXISTING AT&T FIBER RACI EXISTING AT&T EQUIPMENT NOTE: PROPOSED AT&T LTE ANTENNAS/MOUNT AND MOUNTING HARDWARE TO BE PAIN] TO MATCH EXISTING SITE CONDITIONS. EXISTING AT&T FIBER PAN EXISTING AT&T BBU CABIN EXISTING AT&T PPC CABIN EXISTING AT&T A/C CONTI EXISTING AT&T UMTS CABI EXISTING 3'-0" WIDE HOLLOW METAL DOOR PROPOSED AT&T (6) 1-5 CABLES ROUTED ON EXIST INTERIOR CABLE TRAYS (F EXISTING (2) AC UNITS AE EXISTING AT&T TELCO BO/ 1 PROPOSED LTE EQUIPMEN' A-5 MOUNTED ON PROPOSED PROPOSED AT&T (2) DC I FIBER RUN ROUTED ON E: INTERIOR CABLE TRAYS (F EXISTING AT&T DISTRIBUTIC,IN I /1In- STING OVERHEAD POWER LINE STING EDGE OF SIDEWALK )POSED AT&T LTE ANTENNA 6 PER SECTOR, 3 TOTAL) F_ OCATED EXISTING AT&T PANEL 'ENNA (3) TOTAL, (1) PER SECTOR STING 53'-6" HIGH _ITY POLE )POSED AT&T ANTENNA MOUNT 4 -6 )POSED AT&T TMA'S 2 1NTED BELOW ANTENNA PER SECTOR, 3 TOTAL) STING OVERHEAD TELCO LINE IPOSED AT&T LTE ANTENNA 6 PER SECTOR, 3 TOTAL) F_ ;TING OVERHEAD POWER LINE 'POSED AT&T (6) 1-5/8" COAX CABLES ITED WITHIN EXISTING U.G. CONDUITS TING AT&T UNDERGROUND COAXIAL LE CONDUITS TO ANTENNAS TING AT&T DOG HOUSE TING AT&T UTILITY RACK POSED AT&T GPS ANTENNA INTED AT EXISTING H-FRAME F- TING TREE TING COAX CABLr TS (3) TOTAL POSED (3) PORT WAVEGUIDE NTED BELOW EXISTING TING AT&T GPS ANTENNA NTED AT EXISTING H-FRAME TING BUILDING TING AT&T (2) GSM CABINETS DOORS REMOVED POSED AT&T 70OMHZ RRH UNIT 3 4 ;KED MOUNTED AT PROPOSED RAME (1 PER SECTOR, 3 TOTAL) A-5 F- POSED AT&T DIPLEXERS STACKED 3 1 NTED AT PROPOSED H-FRAME 'ER SECTOR, 6 TOTAL) A-5 F- POSED AT&T AWS RRH UNIT r T"V 3 :KED MOUNTED AT PROPOSED RAME (1 PER SECTOR, 3 TOTAL) A-5 F- 24%36" SCALE: 3/4" = 1'-0" 1 1 %17" SCALE: 3/8" = V-0" 1, 6" 0" -,' PROPOSED EQUIPMENT & ANTENNA PLAN 1 x at&t Your world. Delivered. PACIFIC TELECOM SERVICES, LLC 8828 EGISTERED VA RCHIT T ICHARD B. HALL STATE OF WASHINGT* s EXPIRATION DATE OF THE LICENSE: 08/20/13 F� � N (n LIJ O O 00 0) U) N < O J Q W LLJ h� REVISIONS NO. DATE DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE PROPOSED EQUIPMENT & ANTENNA PLAN SHEET NUMBER A-3 I Ht IIVrUKMHI IUIN I UN ININLU ITV I r7IJ JL I Ur I.UIVJ I uk-, i IUIV VUL UIVICIV I J IJ r-mkJr'RIC IHrC I D I IV/"\I URL. /11V 1 UJL UI\ VIJI LVJVI\L U I I ILI\ 11V 11 YYI IIUI I I\LL I LJ V Vnl\I\ILI\ JLI\V IULJ IJ J I RIU I L I rf\UF-IIDI 1 LV. NOTE: PROPOSED AT&T LTE ANTENNAS/MOUNT AND MOUNTING HARDWARE TO BE PAINTED TO MATCH EXISTING SITE CONDITIONS. �� I JJ JJ 24"x36" SCALE: 1/8" = 1'-0" PROPOSED SOUTHEAST ELEVATION 2 24"x36" SCALE: 1/8" = 1'-0" EXISTING SOUTHEAST ELEVATION 1 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' 0" 8' 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' 0" 8' at&t Your world. Delivered.'. PACIFIC TELECOM SERVICES, LLC 8828 R GISTERED 4 RCHITECT C _ (CHARD B. HALL STATE7iPWASHINGTON EXPIRATION DATE OF THE LICENSE: 08/20/13 N (n LIJ O CO 0-) Q W � N O J Q cr- W n 0 W LL 1� REVISIONS NO. DATE DESCRIPTION INITIAL A 12/07/11 ISSUED FOR PCD REVIEW RC 0 04/04/12 ISSUED FOR FINAL CONSTRUCTION RLD NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET SHEET TITLE EXISTING & PROPOSED SOUTHEAST ELEVATION SHEET NUMBER A-4 FHE INFORMATION CUN IAINLU IN I H15 �)L I Uf UUINJ I KUI, I IUIN UUUUIVILN I t) IJ F NUI--'KIL IANT bT INAI UKL. HIV T UJL UK UIJULUJUML U I MLrC I I'li-HIV I r-Imi VVrMIrl fCCLHI LJ U JLrCVII.LJ IJ J 1 MK, 1 LT r-MUC7 UJ I LU.