Loading...
05-105180 (2)t 0 i RETAINING WALL PLAN V N SCALE: 1 "=20'-O" _ F- O Iq Z v_ —_—_—__—.—_—_ --- ----_—_—--- —__----_.__-- DISCLAIMER: BASE DRAWINGS CONTAINING SURVEY INFORMATION USED IN THE WALL LAYOUT WAS PROVIDED BY OTHERS. ANDERSON-PEYTON DOES NOT GUARANTEE OR ASSUME LIABILITY FOR THE ACCURACY OF SAID SURVEY INFORMATION. J J L d d J Z mI J aI J zQl J aI S of 310.00' i i I I 310.00' 305.00' 305.00' 300.00 _ _ _. —_ ._ _ EXPANSION JOINT TYP, -__ _ _ - .. SEE. DETAIL ON-S1.0. CONTROL JOINT_TYP, _._ . _.- _ _- 1 &4 _ _.- _ _._ _. _- _. _ _.. _ __ __.__ _ _ _ _ _ _ _ _ — _ _ _ _ _-_ CONTROL JOINT TYP 300.00 295.00' SEE DETAIL ON S1.0. S1.0 _.�_ NEW FINISH GRADE BEYOND _ _-__ _ ._ ___ _ . ___ _ ___ _ .__.._. SEE DETAIL ON S1.O. ._ _ . _ _ _ _ _ ._ _ _ _ __. - _ 295.00' 19'-5 - - 19 _z 1/2..-- 19•-2 1�2,"__ _ 18'-7;; _. _..18'-7"_ 18 �;; - 18'-7" 18'-7" 18'-7" 18'-7" 17 7" 1T-8" 1T-8" _ 1T-8" I�,-8;- 1T-8" 1T-8" 18'-3" 18'-3" 18'-3" 18'-3" _ 290.00' ___ _ _ - _.__ _ _._ - ._ _ 290.00' ------------- ------------ ----- 285.00 ----------------- FINISH GRADE ----------------------- --- ------------------------------------------ -------------- ------------- _- . ELEV. = VARIES 285.00 __ BOTTOM OF FTC_- 280.00' 10' KEY _ 280. 275.00' 1'-6 KEY _STEP FTG PER.,DETAIL _ _ _ . 1' 6" KEY EXPANSION JOINT TYP,10" _ _. _.._ _ _ _ _. _. _ SEE DETAIL ON__S1 0. _ KEY 275.00' 270.00' 2'-4" KEY--3'-2" KEY 18" MIN 2'-4" KEY 2/S1.0 TYP FINISH GRADE AT FACE OF WALL PER gVIL 270.00' 10' WALL HEIGHT, 67't 8' WALL HEIGHT, 31't 6' WALL HEIGHT, 258.5't 4' WALL HEIGHT, 7.5'tJ 6' WALL HEIGHT, 6'f L 8' WALL HEIGHT, 6't 4' WALL HEIGHT, 9't RETAINING WALL 2 - ELEVATION SCALE: 1"=20'-O" INSIDE LOOKING OUT J r d J QI wl mI QI NOTE: AT CONTRACTORS OPTION, SHORTER WALL HEIGHTS MAY BE BUILT TO TALLER WALL HEIGHT STANDARDS AS SHOWN IN THE "RETAINING WALL AND REINFORCEMENT SCHEDULE". STEPS NOT DIMENSIONED, VARY PER SITE CONDITIONS, WALL SHALL NOT BE TALLERTHAN y&4 SHOWN, TYP-, _.. _ _ _ _ .. _ __ _-...... _ _ --- _ — - - --- - — - — -- EXPANSION JOINT .2 — - - �- - — _ -._ _ ___ _. -_ I . ' - - -' 305.00' CONTROL JOINT TYP EXPANSION JOINT TYP, SEE DETAIL_ ON, S1.0. SEE DETAIL ON S1.0. NEW FINISH GRADE BEYOND .__ _ -_ _ -_ _ _ SEE DETAIL ON SIA _ _ _ _...___ - _ _ . ---_ _ _ _ _ .__._ _. _ _ __ _ __ -. --------- -- _ 19 -0 19 0 19 -0 19 -0 19 -0 18 -7 18 -7 18 -7 18 -7 18'-7" 18 -7 TW 18 -7 t fi =3 172" ' 16 -9 1 2" 16,_9 ..1/2» . 16 -91 /2" 16'=9 1 /2 300 00, _ — _ _ 300.00, 295.00' _ .. _ _ _. _.�_.. _ _ _ _ _ - - - --- STEP TOP OF T 1 INCREM ALL NT 295.00 290.00' ---- ------------ -- ---- -- � _j 18 MIN .... ._._ - _ _ � - ------ ;-- (TYP),ELEV. 290. oo, 288 QQ ' 285.00FINISH GRADE 286.50' 285.00' 280.00' 10' KEY 280.00' _._ -_- _ 275.00' _ � _ — _ _ — _ _ ._ �. _ ._- _ _._._ _ ---•- -- _-_ ._ KEY 3'-2"_KEY..:_ _ _ _ _. _ _ _ _ _ .__ - — _ -_ _ .. _ .. _ _ __..._ - _ 3'-9" KEY FlNiSH GRADE AT FACE OF WALL.. PER _CIVIL__- -- _ _F _ _ 3 . 2" KEY 1'-6" KEY 275.00' .._.___ _ 270.00' 2'-4" KEY 270.00' 10' WALL HEIGHT, 228't 12' WALL HEIGHT, 74't RETAINING WALL 1 - ELEVATION SCALE: 1"=20'-O" INSIDE LOOKING OUT rim eytc>000 10' WALL HEIGHT, 13't -1 8' WALL HEIGHT, 13't 4' WALL HEIGHT, 6.5't 6' WALL HEIGHT, 13.5'f structural Engineering Consultants 0 r. O gc, J o P� �° ) a 3 n Ha O Ln z _ �� let o 0 0 L40 I z 0 a z o W � � 3 �Q U w M � s— F-+ U W Z d q L7 W C7 CA W a Q Q C/1 41 a0 w w 0 w a z W A SUBMITTAL SET ONLY NOT FOR CONSTRUCTION S UCTION THESE DRAWINGS ARE SUBJECT TO REVISIONS PENDING LOCAL JURISDICTIONAL ..j REVIEW. NOV': 0 6 2007 CITY OF FEDERAL WAY BUILDING DEPT. S260 ON O Q z w LL FENCE/GUARDRAIL AS REQ'D PER CODE, BY CIVIL. HORIZ. WALL REINF THICKNESS REINF. 8" #5 @ 18" O.C. 10" #5 @ 15" O.C. O w J J Q HORIZ. FOOTING REINF THICKNESS REINF. 1'-2" #5 @ 10" O.C. 1'-0" #5 @ 12" O.C. 10" #5 @ 15" 0. C. TW = TOP OF WALL TF = TOP OF FOOTING #5 @ 15" U.C., MIN (2) HORIZ BARS IN KEY. C ' 1 TW TOP OF WALL MAY BE CHAMFERED PER OWNER 3:1 MAX/ FINISH GRADE NOTE: AT CONTRACTORS OPTION FULL HT. TYPE "A" BARS MAY BE USED AND #5 VERTS. MAY BE ELIMATED 1-1/2" CLR FULL HT. #5 BAR TO LAP W/ BAR "A". 0 THE 10' WALL THIS BAR MAY BE SPACED 0 10" O.C., @ THE 12' WALL THIS BAR MAY BE SPACED @ 6" O.C. D *BACKFILL & COMPACTION PER SOILS ENGINEER & GENERAL NOTES BAR "A„ CONSTRUCTION JT. W/ ROUGHENED SURFACE DRAIN ROCK 4"4 PERF PIPE, DRAIN TO DAYLIGHT �o FILTER FABRIC 2" CLR P 3" CLR HORIZ. FTG REINF. SEE TABLE BAR "B" x8"r- 2" CLR w �� NATIVE UNDISTURBED SOIL OR COMPACTED FILL, GEOTECHNICA ENGINEER TO VERIFY. TOE I STEM I HEEL TOTAL FOOTING DESIGN PARAMETERS CAMPUS CREST 1. SOIL BRG. = 3000 PSF 2. ACTIVE FLUID PRESSURE = 45.5 PCF 3. PASSIVE FLUID PRESSURE = 350 PCF 4. SOIL FRICTION COEF. = 0.45 5. SOIL UNIT WEIGHT = 120 PCF 6. SEISMIC = 39.5 PSF/FT @ 0.61H NOTES: 1. PROVIDE CORNER STEEL @ FTG. CORNERS & INTERSECTIONS. USE #5x24"x24" ELBOW STEEL TO LAP HORIZ. REINF. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND HEIGHTS PRIOR TO CONSTRUCTION. NOTIFY ENGR./ARCH OF ANY DISCREPANCIES. 3. RETAINING WALL FOOTINGS TO BE STEPPED AS SHOWN, SEE DETAIL 2/S1.0. 4. REINFORCEMENT SHALL BE GRADE 60 FOR ALL BARS. 5. CONCRETE STRENGTH SHALL BE A MIN. OF 3000 PSI @ 28 DAYS. XP E OSED CONCRETE SHALL HAVE 5% AIR ENTRAINMENT. 6. PROVIDE FREE DRAINING BACKFILL BEHIND WALL PER DIRECTION OF SOILS ENGINEER. 7. TENSION SPLICES TYPE "B" FOR ALL LAP CONNECTIONS ETWN. BAR "A" & FULL HT. BAR. WALL HEIGHT FOOTING DIMENSIONS KEY DEPTH BAR "A" BAR "B" BAR "D$$ TOE STEM HEEL TOTAL »T» THKNS "H" HORIZ. "V" VERT. SIZE & SPACING SIZE & SPACING "H" HORIZ. 'IV,. VERT. SIZE & SPACING 12'-0" 2'-0" 10" 7'-2" 10'-0" 1'-2" 3'-9" 2'-7" 4'-7" #5 @ 3" O.C. #5 @ 3" O.C. 6" 6'-8" #5 @ 15" O.C. 10'-0" 1'-6" 10" 4'-11" 7'-3" 1'-0" 3'-2" 2'-1" 4'-5" #5 @ 5" O.C. #5 @ 5" O.C. 4" 5-11" #5 @ 15" O.C. 8'-0" 1'-3" 8" 4'-1" 6'-0" 1'-0" 2'-4" 1'-8" 2'-10" #5 @ 8" O.C. #5 @ 8" O.C. 4" 5-1" #5 @ 16" O.C. 6'-0" 1'-3" 8" 2'-10" 4'-9" 1'-0" 1'-6" 1'-8" 2'-10" #5 @ 16" O.C. #5 @ 16" O.C. 4" 4'-3" #5 @ 16" O.C. 4'-0" 1'-3" 8" 1'-3" 3'-2" 10" 10" 1'-8" FULL HT #5 @ 18" O.C. #5 @ 18" O.C. 4" 3'-5" #5 @ 18" O.C. r ) 1 RETAINING WALL AND REINFORCEMENT SCHEDULE VERTICAL EXPANSION - JOINT (LOCATE AS SHOWN ON ELEVATION) a STOP REINF. @ JOINT EXPANSION JOINT CONTROL JOINT - (LOCATE AS SHOWN ON ELEVATION) 1/2" DEEP CHAMFER 90# FELT BETWEEN WIDTH OF WALL 1/2" DEEP CHAMFER STOP EVERY OTHER WIDTH OF WALL HORIZ BAR @ JOINT CONTROL JOINT CONTROL & EXPANSION JOINT STEMWALL W/ VERT REINF PER DETAILS (NOT SHOWN FOR CLARITY) 24* LAP TYP @ STEP 0 4'-0* MIN TOP OF FOOTING \r �- FIRM UNDISTURBED SOIL \� FOOTING 2 THICKNESS V�� 1 TYP LONGITUDINAL FTG REINFORCEMENT A 3" CLR Z REINFORCED STEPPED FOUNDATION TYPICAL NOTES: 1. PROJECT LOCATED IN FEDERAL WAY, WA. SOUTHWEST OF THE INTERSECTION OF 9TH AVE SW & SW CAMPUS DRIVE. 2. SEE PLANS BY JAEGER ENGINEERING FOR ADDITIONAL INFORMATION. RETAINING WALL NOTES 1.0 GENERAL THESE STRUCTURAL NOTES SUPPLEMENT THE SPECIFICATIONS, ANY DISCREPANCY FOUND AMONG THE DRAWINGS, SPECIFICATIONS, THESE NOTES, AND THE SITE CONDITIONS SHALL BE REPORTED TO THE ARCHITECT, WHO SHALL CORRECT SUCH DISCREPANCY IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE DONE AT THE CONTRACTOR'S RISK. THE CONTRACTOR SHALL VERIFY AND COORDINATE THE DIMENSIONS AMONG ALL DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE CONTRACTOR IS RESPONSIBLE FOR ALL BRACING AND SHORING DURING CONSTRUCTION. 1.1 CODES ALL METHODS, MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF FEDERAL WAY AND: THE 2003 INTERNATIONAL BUILDING CODE (IBC), AS AMENDED AND ADOPTED BY THE CITY OF FEDERAL WAY AND THE STATE OF WASHINGTON; A.C.I. 318-02; A.I.S.C. 13TH EDITION; AWS; A.I.T.C. 2ND EDITION; AND A.I.S.I 1996 EDITION. 1.2 SHOP DRAVANGS SUBMIT SUFFICIENT COPIES OF SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR THE FOLLOWING: 1. REINFORCING STEEL 2. CONCRETE MIX DESIGNS DO NOT FABRICATE PRIOR TO ARCHITECT'S/ENGINEER'S APPROVAL. ALL SHOP DRAWINGS SUBMITTED TO THE ENGINEER SHALL BEAR THE STAMPED APPROVAL OF THE CONTRACTOR. SHOP DRAWING APPROVAL BY ANDERSON-PEYTON STRUCTURAL ENGINEERS SHALL NOT IMPLY THAT THE PROJECT MAY BE BUILT FROM THE SHOP DRAWINGS. RATHER, THE PROJECT PLANS SHALL BE USED FOR CONSTRUCTION. ALL PERMANENT BRACING FOR TRUSSES SHALL BE DETAILED AND DESIGNED BY THE TRUSS SUPPLIER. CONTRACTOR SHALL REVIEW SHOP DRAWINGS AND STAMP INDICATING THIS PRIOR TO REVIEW BY ENGINEER OF RECORD. 2.0 SITE YU= 2.1 SOIL DATA (PER GEOTECHNICAL REPORT f200707 DATED 03/05/07 PREPARED BY BERGWIST ENGNEEROiG) FOR LOCATIONS SEE SOILS REPORT. SOIL BEARING @ CONT. SPREAD FOOTINGS = 3000 PSF. ACTIVE AND PASSIVE PRESSURES ARE (32.5-45.5) PSF AND 350 PSF RESPECTIVELY. Z2 EXCAVATION EXCAVATE FOR FOOTINGS DOWN TO DEPTH SHOWN ON DRAWINGS OR TO FIRM UNDISTURBED MATERIAL. AREAS OVER -EXCAVATED SHALL BE BACKFILLED WITH LEAN CONCRETE (f'c = 750 PSI), OR BE STRUCTURALLY FILLED PER SECTION 2.3 AND SHALL BE AT THE CONTRACTOR'S EXPENSE. 7-3 BACKFILL AND COMPACTION BACKFILL SHALL NOT BE PLACED UNTIL AFTER THE REMOVAL OF ALL FORMS, SCREEDS, OTHER WOOD DEBRIS AND MATERIAL SUBJECT TO ROT OR CORROSION. USE ONLY MATERIALS APPROVED FOR BACKFILL. IN AREAS UNDER SLABS OR FOOTINGS, MATERIAL SHOULD BE GRANULAR IN NATURE, PLACED IN 6-INCH LIFTS AND COMPACTED TO AT LEAST 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY AASHTO COMPACTION TEST, PROCEDURE T-180 (OR PER GEOTECHNICAL ENGINEER). THE FILL SHOULD BE LIMITED TO CLEAN, GRANULAR MATERIAL. &0 CONCRETE 3.1 GENERAL NORMAL WEIGHT CONCRETE MEETING THE REQUIREMENTS OF ACI 301-96 ESTABLISH PROPORTIONS OF CEMENT, COARSE AND FINE AGGREGATES, WATER, AND ADMIXTURES TO PRODUCE THE PROPERTIES SPECIFIED FOR EACH CONCRETE MIX TYPE PER ACI- 301 ON THE BASIS OF PREVIOUS FIELD EXPERIENCE OR TRIAL BATCHES. USE ADMIXTURES IN ACCORDANCE WITH THE MANUFACTURER'S DIRECTIONS. USE AMOUNTS OF WATER - REDUCING ADMIXTURE THAT WILL PERMIT PLACING WITHOUT SEGREGATION, HONEYCOMBING OR ROCK POCKETS. THE SLUMPS SPECIFIED ARE THE SLUMPS REQUIRED AT THE POINT OF PLACEMENT INTO THE STRUCTURE. USE INTERIOR MECHANICAL VIBRATORS WITH 7000 RPM MINIMUM FREQUENCY. DO NOT OVER - VIBRATE. DO NOT MOVE THE CONCRETE HORIZONTALLY USING THE VIBRATOR. CONCRETE SHALL BE POURED MONOLITHICALLY BETWEEN CONSTRUCTION OR CONTROL JOINTS. PROTECT ALL FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE HOT OR COLD TEMPERATURES FOR SEVEN DAYS AFTER POURING. PROVIDE ENGINEER WITH PROPOSED CONSTRUCTION OR CONTROL JOINT LOCATIONS FOR HIS APPROVAL, OR USE JOINTS AS SHOWN ON THE DRAWINGS. ALL REINFORCEMENT TIE WIRES AND FORM ANCHORS SHALL BE CUT OFF FLUSH WITH THE SURFACE; SURFACES WHERE EXPOSED SHALL BE SMOOTH AND FREE FROM IRREGULARITIES. 3.2 STRENGTH CONCRETE SHALL HAVE A MINIMUM STRENGTH OF 3000PSI @ 28 DAYS. PER SECTION 1904, CONCRETE EXPOSED TO WEATHER SHALL HAVE 5% AIR ENTRAINMENT. &3 MATERIAL - CEMENT, WATER & AGGREGATES PER ACI 301 A. CEMENT MUST CONFORM TO ASTM C-150, TYPE I OR TYPE II. ENGINEER'S APPROVAL IS REQUIRED FOR USE OF TYPE III CEMENT. B. WATER TO BE CLEAN AND POTABLE. C. COARSE AND FINE AGGREGATES TO CONFORM TO ASTM-C33. 3.4 MATERIALS A. WATER REDUCING ADMIXTURES: CONCRETE USING POZZOLITH ADMIXTURES TO PRODUCE FLOWABLE CONCRETE MAY BE USED WITH THE ENGINEER'S APPROVAL AND MUST CONFORM TO ASTM-C494, POZZOLITH POLYHEED, POZZOLITH 100XR, OR POZZUTECH 20. POZZOLITH SHALL BE INCORPORATED INTO ALL CONCRETE IN EXACT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ADMIXTURES AND DOSAGES WILL VARY DEPENDING ON CLIMATIC CONDITIONS AND THE CONTRACTOR'S JOBSITE REQUIREMENTS. MAXIMUM SLUMP FOR SUCH CONCRETE SHALL NOT EXCEED 8" WITH A MINIMUM OF 10 OUNCES OF POLYHEED PER 100 OUNCES OF CEMENT. USE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. B. AIR ENTRAINMENT: CONFORM TO ASTM-C260 AND ASTM- C494, MBVR OR MICRO -AIR BY MASTER BUILDER. ENTRAIN 5% +/- 1% AIR BY VOLUME IN ALL EXPOSED CONCRETE. C. OTHER ADMIXTURE: NO OTHER ADMIXTURES PERMITTED UNLESS PRIOR APPROVAL IS GIVEN BY THE ENGINEER. NO ADMIXTURES CONTAINING CHLORIDES ARE PEDY`7D. 15 REINFORCNG STEEL DETAIL, FABRICATE AND PLACE PER ACI-315 AND ACI-318. SUPPORT REINFORCEMENT WITH APPROVED CHAIRS, SPACERS, OR TIES. A. STEEL REINFORCEMENT SHALL BE NEW, DEFORMED BILLET STEEL, MEETING ASTM STANDARD A-615 GRADE 60 FOR #3 AND LARGER BARS UNLESS NOTED OTHERWISE ON THE PLANS. SHOP DRAWINGS SHALL BE MARKED ACCORDINGLY AND SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION. GRADE 60 REBAR SHALL NOT BE BENT IN FIELD AFTER CONCRETE PLACEMENT. ALL BENDS SHALL BE PER ACI. B. REINFORCEMENT IN ALL WALLS AND FOOTINGS SHALL BE CONTINUOUS AROUND CORNERS OR CORNER BARS PROVIDED, BOTH VERTICAL AND HORIZONTAL. C. LAPS: ALL TENSION SPLICES ARE ACCORDING TO ACI 318, CLASS B (50 DIAMETERS, U.N,O.) AND ALL COMPRESSION SPLICES ARE 30 DIAMETERS FOR f'c GREATER THAN 3000 PSI AND 40 DIAMETERS FOR f'c LESS THAN 3000 PSI. ALL OTHER LAPS SHALL BE 12" MIN, D. WELDING: TACK WELDING OF REBAR IS NOT PERMITTED UNLESS CALLED FOR AND APPROVED BY THE ENGINEER. E. MINIMUM REINFORCING: WHERE REINFORCEMENT IS NOT SHOWN ON THE DRAWINGS, THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318) SHALL BE REFERRED TO FOR PROPER REINFORCEMENT. F. REBAR COVER: PROVIDE CONCRETE PROTECTION FOR REINFORCEMENT AS FOLLOWS: COVER CONDITION AGAINST A 1-1/2" CONCRETE DEPOSITED AGAINST FORMS BUT EXPOSED TO EARTH 4,0 SPECIAL INSPEC7K* SPECIAL INSPECTIONS SHALL CONFORM TO SECTION 1702 AND 1704 OF THE 2003 IBC AND ARE REQUIRED DURING THE FOLLOWING: A. THE EXCAVATION OF FOOTINGS PRIOR TO CONCRETE PLACEMENT, B. THE TAKING OF CONCRETE TEST SPECIMENS, C. THE PLACEMENT OF REINFORCING STEEL OF ALL STRUCTURAL FOOTINGS, WALLS, AND APPENDAGES. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE A SCHEDULE OF REQUIRED INSPECTIONS AND SHALL SUBMIT THIS SCHEDULE TO THE ARCHITECT AND ENGINEER FOR APPROVAL. "INSPECTION" IS INSPECTION PERFORMED BY THE BUILDING OFFICIAL AT VARIOUS STAGES OF A PROJECT AS OUTLINED IN IBC SECTION 109 TO ENSURE COMPLIANCE TO THE BUILDING CODE. SPECIAL INSPECTION SHALL BE DONE BY THE OWNER'S INSPECTOR WHERE IBC CHAPTER 17 (REF SECTION 1704) REQUIRES SPECIAL EXPERTISE TO ENSURE COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. STRUCTURAL OBSERVATION SHALL BE PERFORMED BY A REGISTERED DESIGN PROFESSIONAL FOR GENERAL CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AS DEFINED IN IBC SECTION 1702. STRUCTURAL OBSERVATION DOES NOT INCLUDE OR WAIVE THE RESPONSIBILITY FOR INSPECTION AS REQUIRED BY IBC SECTIONS 109 OR 1704. 5.0 MISCELLANEOUS VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING. PROVIDE ERECTION BRACING AS NE SARY N I r 105 1 Q PERMANENT SUPPORT AND STIFFNESS ARE INS T ED. 6j RESUBMITTED N O V` 0 ,6 2007 CITY OF FEDERAL WAY BUILDING DEPT. rpv 0 33� o 00 N �Fa �z Icp 0 � � o H � � x � � 3 �Q w Aq l� 1 M � � O CD �-- O / m \ 1 °z Q W Q SUBMITTAL SET ONLY OT FOR CONSTRUCTION 11JESE DRAWINGS ARE SUBJECT TO VISIONS PENDING LOCAL JURISDICTIONAL S160 him A"clerSc.>ri - Pe tc:n 000 Structural Engineering Consul tan is