Loading...
11-100542 (2)4" TRIM 4" BEVE 4" MM (TYP) 4' BEVELED 510ING 6" TRIM AT ALL WINDOWS 8 DOORS LAMB'S GATE PRESBYTERIAN CHURCH OF SEATTLE PASTOR KWANG H, KIM 2a850 le th AVENUE SOUTH. FEDERAL WAY, WA5HINOTON c0005 REAR ELEVATION SCAM 1141- r COMP ROOFING OVER 15# BUILDING PAPER 12" RIGHT ELEVATION SCALE 1/4•-1' 1 6t --- r—comp ROOFING OVER 15# BUILDING PAPER 6 t-- 12 TRIM TRIM MIR) BEVELED SATING (r.(N COMP ROOFI1,16 OVER 15# BUILDING PAPER RESUBMITTE Permit Number Lc_ —� JUL 2 6 2011 ApWved BY4 , ,- CITY OF FEDERAL WAY Date' CDS Copr 0 N 0 a A 054 N � N VJ1�S 00 l.1155 LAMB'S GATE PRESBYTEPJAN GF9iRC 4 OF 5EA7TLE 29850 IBTH AVENIE SOUTH PE>aERAL WAY, WASHINGTON a8003 Ject LAMB'S &ATE PREwyTERIAN OHURrH 2ga50 l87N ftVENIfE SOUTH f•�EDERAL WAY, WASHINOTON Q8003 ELEVt ATIONS TIO,glptlon dras�rt � LEONARD 5. BERNHOFT cam"' L5B /BSMACV sGQ e d AS SHOM 0410612011 I dtsctplina I ,job num-err "'- 2011-1-1 5heet r 3 A-5 -j ROCKERY I 2-10" HEM I I o I 26 Fill I uJ a ;„� a y' 2 FIB \ e ° f _. EX. 10' DRAINAGE ESMT. Il —. ti..-.,24» FIR ° 4 V I\\ 6625 / (RFC NO 31) I I U ° — r li d °°i G S II ° 20 CED /( I L ° ° I ll...... i . .. .. / W • 18" IR I O II00 IlIl A=49'47'11"C....,:..:....... R=88.753 (C)(P)° a SIG SOY - 30' sE(TYP.� Nw . L=77.12'(C� �d W ......... - "."..:. . 3 651 S.F. W W EAW W W W O ' 24" FIR ' W W W / ll //00 MIN. 10' TYPE III LANDSCAPING (TYP.) _ X ❑ -- ❑ ❑ Nag- 7'`65�'W-4 X X X X 100'f (10' WIDE) TYPE II LANDSCAPING Il �/ EX. 10 SEWER ESMT. (AS SHOWN ON ll APPROVED LAKEHAVEN UTILITY DISTRICT LANDSCAPE AREAS: LAWN AREA CALCULATION: PROJECT REV. —14— 7 DATED 29-0 ) REV. 3-14-07, REV. 5-29-08) it li IC TYPE III BUFFER: 7,185 S.F. TOTAL LANDSCAPE AREA: 19,457 S.F. II III I LANDSCAPED SLOPE: 2,533 S.F. TOTAL LAWN AREA: 6,896 S.F. II PARKING LOTS: 2,943 S.F. LAWN AREA AS A % OF TOTAL: 35.44% II II III II LAWN AREAS: 6,896 S.F. PRESENCE OF EXISTING I Ill it SIGNIFICANT TREES: SEWER LINE MAY REQUIRE II I LANDSCAPE: MODIFICATION OF PLANT IIl f PARKING LOT LAN. I III I THE SITE CONTAINS 12 SIGNIFICANT TREES SELECTIONS lI III I REQUIRED: 20 S.F./STALL OR 800 S.F. MIN. WITH A CALIPER OF 12" OR GREATER. 9 TREES WE PLAN Apr&oval, I Il I PROVIDED: 2,943 S.F. ARE TO BE SAVED, 3 TREES ARE TO BE Ptx III d �► �y; - II I REMOVED, SAVING 75% OF SIGNIFICANT TREES. tom: II I� III I REPLACEMENT TREES ARE NOT REQUIRED.; GOP�IAPHIIC SCALE 10 20 ( IN FEET ) 1 inch = 20 ft. 25' SLOPE SETBACK TOE OF STEEP SLOPE 40 REV. NO. DATE DESCRIPTION APPROVED . - S DALEY-MOFIROW—POBLETE, INC. CLIENT LAMB'S GATE PRESBYTERIAN CHURCH �0 P� 726 AUBURN WAY N. WAsyAUBURN, `�NASHINGTON 98002 29850 18th AVE. S., FEDERAL WAY, WA. 98003 �F � �lF ti PHONE: 253-3.3_-2200, FAX: 253-333-2206 PHONE No. (253)632-9101 PROJECT LAMB'S GATE PRESBYTERIAN CHURCH PRELIMINARY LANDSCAPE PLAN l 28352 0 �� ENGINEERING — SURVEYING F' ' l S T Eyl G��`� Q D LAND PLANNING IONAL E� incorporataa DRAWN By LM SCALE 1" = 20' DRAWING 11105ENG 11 SHEET ------- aaPRovED ASP DATE JUL. 22, 2011 does 11105 of ----12 STAMP NOT VALID UNLESS SIGNED DATED ------ o. not ­1 1 1 _ 111 1 .— In— 17 -1— A Mis10 - A E PREP' CAI SW 114 OF SECTION 4, GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE FEDERAL WAY CITY CODE (FWCC), APPLICABLE ORDINANCES, AND THE CITY COUNCIL CONDITIONS OF PROJECT APPROVAL. THESE DOCUMENTS ARE SUPPLEMENTED BY THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION (WSDOT/APWA), THE KING COUNTY ROAD STANDARDS (KCRS), AND THE KING COUNTY SURFACE WATER DESIGN MANUAL (KCSWDM). IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL ENGINEER TO CORRECT ANY ERROR, OMISSION, OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THESE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST OR LIABILITY TO THE CITY OF FEDERAL WAY. 2. THE DESIGN ELEMENTS WITHIN THESE PLANS HAVE BEEN REVIEWED ACCORDING TO THE FEDERAL WAY ENGINEERING REVIEW CHECKLIST. SOME ELEMENTS MAY HAVE BEEN OVERLOOKED OR MISSED BY THE CITY ENGINEERING PLAN REVIEWER. ANY VARIANCE FROM ADOPTED STANDARDS IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF FEDERAL WAY, PRIOR TO CONSTRUCTION. 3. APPROVAL OF THIS ROAD, GRADING, AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (I.E. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICITY, ETC.) 4. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY, A PRECONSTRUCTION MEETING MUST BE HELD BETWEEN THE CITY OF FEDERAL WAY, THE APPLICANT, AND THE APPLICANT'S CONSTRUCTION REPRESENTATIVE, 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. CONSTRUCTION NOISE SHALL BE LIMITED AS PER FWCC (SECTION 22-1006); NORMALLY THIS IS 7 A.M. TO 8 P.M., MONDAY THROUGH FRIDAY AND 9 A.M. TO 8 P.M. ON SATURDAYS. 7. IT SHALL BE THE APPLICANT'S/CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK WITHIN THE ROAD RIGHTS OF WAY. 8. FRANCHISED UTILITIES OF OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL CITY REQUIREMENTS AND THE REQUIREMENTS OF KCRS CHAPTER 8 ARE SUBMITTED TO THE CITY OF FEDERAL WAY AT LEAST THREE DAYS PRI,:'K TO CONSTRUCTION. 9, VERTICAL DATUM SHALL BE KCAS OR NG"r_'--29. 10. GROUNDWATER SYSTEM CONSTRUCTION S-;ALL_ BE WITHIN A RIGHT OF WAY OR APPROPRIATE DRAINAGE EASEMENTS, BUT NOT JNDERNEATH THE ROADWAY SECTION. ALL GROUNDWATER SYSTEMS MUST BE CONSTRUCTED IN ACCORDANCE WITH THE WSDOT/APWA STANDARD SPECIFICATIONS. 11. ALL UTILITY TRkNCHES IN THE RIGHT OF �':AY SHALL BE BACKFILLED WITH 5/8 INCH CRUSHED ROCK AND COMPACTED TO 95% DENSITY. WHEN TRENCH WIDTH IS 18 INCHES OR LESS, AND IS WITHIN THE TRAVEL' D WAY TRENCH WILL BE BACKFILLED WITH CONTROL DENSITY FILL (SELF -COMPACTED FLOWABLE FILL AS DEFINED BY WASHINGTON AGGREGATES AND CONCRETE ASSOCIATION. THE AGGREGATE WILL BE 3/8-INCH MINUS. 12. ALL ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95% DENSITY IN ACCORDANCE WITH WSDOT 2=06.3. 13. OPEN CUTTING OF EXISTING ROADWAYS IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE PUBLIC WORKS DIRECTOR AND NOTED ON THESE APPROVED PLANS, ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH KCRS 8.03(B)3. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACTOR. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL. TRAFFIC FLOW SHALL REQUIRE AT LEAST ONE FLAGGER FOR EACH LANE OF TRAFFIC AFFECTED. ALL SECTIONS OF THE :WSDOT STANDARD SPECIFICATIONS 1-07.23-TRAFFIC CONTROL, SHALL APPLY. 15. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REGULATORY AND WARNING SIGNS PER THE LATEST EDITION OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. 16. ALL UTILITIES SHALL BE ADJUSTED TO FINAL GRADE AFTER PAVING ASPHALT WEARING COURSE. 17. ROCKERIES ARE CONSIDERED TO BE A METHOD OF BANK STABILIZATION AND EROSION ONLY. ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE AS RETAINING WALLS. ALL ROCKERIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH CFW DRAWING NUMBERS 3-22, 3-23. ROCKERIES MAY NOT EXCEED SIX FEET IN HEIGHT FOR CUT SECTIONS OR FOUR FEET IN HEIGHT FOR FILL SECTIONS UNLESS DESIGNED BY A GEOTECHNICAL OR STRUCTURAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. 18. IMMEDIATELY FOLLOWING FINAL INSPECTION OF THE STREET LIGHT SYSTEM, ALL STREET LIGHT SYSTEM J-BOXES SHALL BE SPOT WELDED SHUT USING A 1" WELD ON OPPOSITE CORNERS. OTHER PERMIT: 1. CONTRACTOR WILL GET THE BUILDING PERMIT PRIOR TO LOT GRADING. PERMIT SPECIALIST CAN BE REACHED AT (253) 835--2607 FOR MOR INFORMATION. 2. UTILITY COMPANIES MUST OBTAIN RIGHT-OF-WAY PERMITS FOR UTILITY WORK WITHIN THE PUBLIC RIGHT-OF-WAY: KATHLEEN MESSINGER CAN BE REACH AT (253) 835-2725 FOR MORE INFORMATION. TOWNSHIP 21N, RANGE :CALL: N IS Call before you DIg. 1— 800— 424- 5555 UNDERGROUND SERVICE (USA) AVOID CUTTING UNDERGROUND UTILITY LINES. IT'S COSTLY NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. CALL BEFORE YOU DIG: 1-800-424-5555. 4E, W.M. TABLE OF CONTENTS .5HEXT NO. TITLE 1 OF 12 COVER SHEET 2 OF 12 EXISTING CONDITION 3 OF 12 HO \i7ONTAL SITE PLAN 4 OF 12 T.E.S.C. AND DETAILED GRADING PLAN 5 OF 12 T.E.S.C. AND DETAILED GRADING NOTES AND DETAILS 6 OF 12 ROAD AND STORM PLAN 7 OF 12 ROAD AND STORM PROFILES 8 OF 12 NOTES AND DETAILS 9 OF 12 NOTES AND DETAILS 1: OF 12 DETENTION POND DETAILS NOT INCLUDED 11 OF 12 LANDSCAPI- PLAN AT THIS TIME 12 OF 12 LANDSCAPE LEGEND, NOTES AND DETAILS 1 OF 2 18TH AVENUE SOUTH IMPROVEMENTS 2 '_`E 2 STREET FRONTAGE DETAILS 1.% GAL DESCRIPTION LOTS 11 AND 12, BLOCK 2, JENNETTE SOUNDVIEW T-''ACTS, ACCORDING TO PLAT RECORDED IN VOLUME 44 OF PLATS, PAGE 68, RECORDS OF KING COUNTY, WASHINGTON DAT UM NGVD 29 BENCHMARK (CITY OF FEDERAL WAY BM 2172-34-1) NORTHEAST BOLT ON SIGNAL BASE AT THE SOUTHWEST QUADRANT OF SOUTH 304th STREET AND PACIFIC HIGHWAY SOUTH. AVENUE SE. ELEVATION 481.96 BASIS OF BEARING THE MONUMENTED CENTER LINE OF 20TH AVE. S. BEARING NOO`26'50"W h1ERIDIAN JEANETTE SOUNDVIEW TRACTS VOL. 44/68-69 SITE ADDRESS 29850 18TH AVE. S, FEDERAL WAY, WA 98003 FARCEL Nos. 3674400155 3674400160 FEDERAL WAY PUBLIC WORKS INSPECTION/ NOTIFICATION PHONE: 253-835-2700 PEFf A . UN cy APPROVED do DATE 8: \PROJECTS\ 11 - 105 LAMBS CATE CHURCH\DWG% 7 1 10' r r r L�J r r COMMERCIAL .. p . / p .... ..: ..... ..... ....... ..... .. .... ... .. .. ... .. .. ... .. ... - ... ...... ..... .. ........ _y' ... ...... ..... ... ........._......... .... ..... r� 1 e, ...}.e }.+-)-�,r '--c' }�:s :..': 3 {tr:� k�•Y,. _yr ..5..1:`..� x,.t. DRIVEWAY x ,.t..< .`. ? .y- _jur t s.z.t _ }.:.:.{... .... 1 . .... �s _. ..:-- ..................... - r .., .. ,. ?�: {,�nS-st? . F. �. . i. .: . ;. , t}'�. � . -. - 2��r �r'i, - Z.>`�r;'., r a` Yti'�5•z'-,:.t'��ri� .. .. _ �...... �-.. •- . ,��,.;-� LOT LIGHT- HAMPTON BAY"� (Q p. ..... o. .., .......�.1�-�-.:: �......:.. = ..� . >.. _ .h:� THREE —HEAD POST LANTERN OR ............ tl-... - - _ ..... �-`�: fir; S.r : ` ,� - cam. ' � s. . ,�.��` � ..��. I o p . '. ,, , /� : . o... ....... T{.<, =# - r<,.}, j. :.,- r..F, EQUAL. TYP. OF 8 z . ( ) N < f x= l r s� } r..r 1= . `-C^ r I .r�. ........... .. t .i a s ......... .. -k' ... L. ........ RELOCATE EX. ST. LGT. 1 p \\Q f_ l �..{ I 1 p ° .n Q .. ... � �T -5. h - "r r �I>. ?St },c ,1� .,i'<.< t} f'YS'Z k)T..( -.i S' x�" r.tr rJ'Z r.Crtr; Zg' l-e�7 TO PLANTER BY s 1\ , . • w {{' { yr ; t� } k ca z ;� sj t' t {k, / OTHERS ........ cr . ` . ^ L � .rc -...F .�1.�. 4). ..... d "C .. rfr'. >"5.... f ?S•c. ..T,y. ! Z. J -', ? a- t� s�_t;.f- . .�-tir,{.. rKi.�.s'�.4 .r`s:- - - - `Jr � 7•�_ L , � � P, x x .) r t:� r :�.[ ,i . y., -� ,r r.? ..t �S=> ; .,. �2'*> S. r . ,`� . . ........ N �• .... ` 7.. .A s. . ��} la', 'a., x. ?..3 °a r rt t .a' d o d I . ..... J ` V �'Z{. 4' - �ta .,4 ,'�Si.$">. 4 8 "MOUNTABLE" CURB � MOUNTABLE C l3 - �I > � �, ., �,, ?•: -- � •, `r___T I�«��� ,:�� r �. �,-� ,.,7,� : r, , s5 r . �;,�.�`�r e .... ..... M INTENANCE ACCESS ry� . - Y.AY7 '�`'4:1i:n'c.Z.. Ott.F}S `"r1.sr:'3; vfr. t r^>>-rr ER W.S.D.O.T. STD/ .....`.� -.. � ,�.,�sa���•.: �.=ti� -;-: �' � � .��`'-• ! � PLAN F-10.12-00 .......... ... n p 1 w-y,C�l' . . . . . . . . / - }C } v 7{'' •(� ?;IJS- ;.., S SJ_`.1 A; Crili.. �' -T''- v' d �[, - GARBAGE & RECYCLING . .. p .... c� w }-<,. �` �. !• 11�k�y . - - - -.-� -{ . r� �'s.:>^;1^'�S S-t.+w�'fJ+ � '• -. C.` � k11 : ��.`t-i,j• : r FSt. r .�} E �} _ > ENCLOSURE (�5 S.F.S F MIN.) Z x ., ,� fly_, t x .t : ,r r,{_, < N , ; . . . . . . . . . . . . . 'J-$S -o' i -< c r,:. tf at v s rY` l- �' e } i��f1} . . . . . . ... l.. - d -.' d ... .. . d 14 p p a C Q p d p d p d d d E DRAINAGE ESMT. (REC. NO.A6625431) . ----- -- - --- - - --- - f p d p d a p p �I ............. ; Lq ... a pd P ZA p d I ram'\ STORMWATER FACILI YCIV 0=49'47'11"(C) ..... :..�,.... ;, R=88.753' C P oc .... da L=77.12' C p _ st ISACK (rYP, v' ....... — — — — I p w d - d-p p N i d d p d e I (fl I-- — ----- ------ d p p . . . . . . .. . ---- J I o 11c ��- N8z3"�7'V5 W 4 9.27'(C) - X X x x - =- - EX. 10' SEWER ESMT. (AS SHOWN ON APPROVED LAKEHAVEN UTILITY DISTRICT PROJECT NO. 6106025, DATED 3-5-07, REV. 3-14-07, REV. 5-29-08) r I III I I IL II _ THREE -HEAD POST LANTERN III, �I _ III I Specifications IIi I Assembled Depth (in.) : 27.5 in Assembled Height (in.) 84 in III II !Assembled Width (in.}: 27.5 in Bulb Type: Incandescent IIII CSA Listed: No I Color/Finish : Black Depth (in)'* 14.53 in Dusk to Dawn: No ETL Listed : No Energy Star Compliant: No - Exterior Lighting Product Type : Post Light Fixture Finish: Black Fixture Material: Cast Aluminum, Steel, Glass Glass/Lens Type: Clear height (in} : 18.43 in REV. NO. DATE I DESCRIPTION APPROVED Item Package Type: Cardboard Container Item Weight: 20.86 lb Light Source: Incandescent M 25' SLOPE SETBACK TOE OF STEEP SLOPE 3 0 (n v / b/ O LL Ld D anufacturer Warranty . N!A - Maximum Bulb Wattage: 100.0 W 17$o Lur FH$ APPROVED DATE ER S . p� DALEY-MORROW-POBLETE, 726 INC. WEAR LAMB'S GATE PRESBYTERIAN CHURCH �Q �Q of WAS/�B� ti F AUBURN AUBURN, WASHINGTON PHONE: (253)333-2200 WAY NORTH 98002 FAX: (253)333-2206 29850 18TH AVE. S, FEDERAL `WAY, WA 98003 PHONE No. (253) 632-9101 1 - PROJECT GATE PRESBYTERIAN CHURCH 28352 / ENGINEERING - SURVEYINGLAMB'S HORIZONTAL SITE PLAN S 10, G���` LAND PLANNING AL �ncorpora to cl DRAWN BY ASP .SCALE 1„ = 20' DRAWING 11105ENG 3--- - SHEET __ STAMP NOT VALID UNLESS SIGNED & DATED APPROVED ASP DATE JUL. 22, 2011 JOB# 11-105 OF ___12_____ Br\PROJECTS\ 11-- 105 LAMBS GATE CHURCH\DWG\ 11105ENC.1 INTERCEPTOR | / | u- ROAD CROSSING WOOD FENCE f"'� m::: . (L 460 CLEARINU V. ' \ \ | \ \ \ � U ! ' U SEDI U U \ '/ | ` ` � || ^ U � || ' U | U U rc " | | U ( U U l0 ���-�' �z' -� O -�'u -7(�' " \ ' '` ^ x --=�— X -------�\ n U h VVO0O FENCE ' VN' U U 3 RE FENCE 5 WOOD FENCE 8 ' - SILT FENCE (TYP') ' N -REV NO- I DA TE DESCRIPTION APPROVED N ' S. DALEY-MORROW-POBLETE, INC. CLIENT LAMB'S GATE PRESBYTERIAN CHURCH 726 AUBURN WAY NORTH 29850 18TH AVE. S, FEDERAL WAY, WA 98003 PROJECT LAMBS GATE PRESBYTERIAN CHURCH SURVEYING R-\PPn.IrrT'Zl 11-7f)'; /AMPIZ =TFr==r"^"=`'`m""^ EROSION/SEDIMENTATION CONTROL NOTES: 1. Approval of this Erosion/Sedimentation Control (ESC) plan does not L UBLIC RIGHT-OF-WAY constitute an approval of permanent road or drainage design (i.e. size P and location of roads, .pipes, restrictors, channels, retention facilities, utilities; etc.). JOINTS IN FILTER FABRIC SHALL BE SPLICED 4.5' 4.5' AT POSTS. USE STAPLES, WIRE RINGS, OR 2"x2" BY 14 Ga. WIRE OR 2. The implementation of these ESC plans and the construction, - 12" MININIMUM EXIST. maintenance, replacement, and upgrading of these ESC facilities is the EQUIVALENT TO ATTACH FABRIC TO POSTS. EQUIVALENT, IF STANDARD PVM'T. 9 9 STRENGTH FABRIC USED responsibility of the applicant/contractor until all construction is approved. FI LTER R FA TE BRIG 3. The. boundaries of the clearing limits shown. on this Ian shall be ..... clearl flogged in the field prior t construction.' rin the - oDu P� U7 Y 999 construction .period, no disturbance beyond the flogged clearing limits 0 N 3-7 •- ., shall be ermitted The fla in shall be maintained b the 1 EXIST. GEOTEXTILE GROUND 1 u7 a licantpcontractor for the duration of y 0.5' MIN. : 100' W >- PP / va r-Q construction. o o KEY ROCK INTO SWALE 04 o Q 4. The ESC facilities: shown on this plan must be constructed in - F -III-III I I. lilt h I z MIN. 400 conjunction with all clearing and grading activities, and in such a IIII�I „ IIIIII�I�II�II�II�III-III III-11..1 III: III - „ Mmanner as. to insure that sediment laden water. does not enter the 14�11�11- drainage system or violate applicable water standards: If-� N m f6' MAX. MINIMUM 4"x4" TRENCH- INTERCEPTOR DITCH X-SECTION & ROCK CHECK DAM - EXIST °O5. e ESC acilities shown on this plan are the minimum requirements for °anticipated site conditions. During -'the construction period, these BACKFILL TRENCH WITH GROUND o 0NATIVE SOIL OR 3 4"-1.5" °o°° OESC facilities shall be upgraded (i.e additional sumps, relocation of POST SPACING MAY BE INCREASED / 0 O FRONT VIEW % % O000ditches and silt fences, etc.) as needed for unexpected storm events. TO 8' IF WIRE BACKING 15 USED WASHED GRAVEL ) %�\\\��\\\%\\\ i\\\ i\\\%\\\%\\\-\\\�i\\\!io °°oJ U^ O 335M000 ODO O00000000000 0 O 0 aDJWQ �\ 8000 0 00 00 $o o2 x4 WOOD POSTS, STEEL FENCE o°4>Q� 8 o a 80 00 6. The ESC facilities shall be inspected dail .b h a lican contractor D X W / 0 0 0 0 8 0 P daily.by the PP t/ POSTS, REBAR, OR EQUIVALENT W c� z % 0 0 006 � and maintained as necessaryto ensure their continued functioning. 1 z a - \ ° o F _ 9 NOTE. FILTER FABRIC FENCES SHALL BE W _ �. �\ 8 4 , TO 8 0 U) INSTALLED ALONG CONTOUR WHENEVERI - MIN. o a - / ° CO OU POSSIBLE QUARRY SPACES x 7. Any area stripped of vegetation, including roadway embankments, where FLOW 5O o w `� o0 0° o W a no further work .is anticipated or a period of 15 days, shall be-� o: a\� o o°o 0 0 0 0 ° P P Ys, 1, ii�, iIi a w o°o°° 000 °080D00000 °o 0 800 8°0 0 0 immediately stabilized with the approved ESC methods (i.e. seeding, - �- o o 0000 0000 0000cbo®o a000 wog0000000 8o0 oo 0 0 ° o8d� mulching, netting, erosion _blankets, etc:) FL -OW %\\\,i\\\ i\\\ i\\\ i\\\ i\\\ i\\\!i\\\!i\\\�i 00 o°° MAINTENANCE STANDARDS �- = SUMP BEHIND ROCK CHECK DAM o 000 0 _iii_ ill: >ri= $ o . - L i _ - SHALL BE INSPECTED DAILY 8c O o 8. Any .area needing ESC measures, not requiring immediate attention, 1. :ANY DAMAGE SHALL_ BE REPAIRED IMMEDIATELY. � -_ _ _ i i � _ / i l,, - > i l _ _ 9 ri I l i t I I= CLEANED WHEN COLLECTED DEBRIS S° pO hall be addressed within 15 days: _ .p ° o 2: IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND 0.5, 1' EXCEEDS 1/2 OF ITS DEPTH` 0CIC • • • KEY ROCK 0 9. The ESC facilities on inactive sites shall be inspected and maintained a CONVEYED TO A SEDIMENT TRAP OR POND. 5 minimum of once a month or within the 48 hours following a storm INTO SIN. . event: . IT I IMPORTANT 0.25' MIN: 3 STO CHECK THE UPHILL SIDE OF THE FENCE FOR. SIGNS OF THE FENCE CLOGGING AND NOTE: ACTING AS A BARRIER TO FLOW' AND THEN CAUSING. CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF K A 4" MIN 10. At no time shall more than one foot of .sediment be allowed to THIS OCCURS, REPLACE THE FENCE 'AND/OR REMOVE THE TRAPPED SEDIMENT ROC SHALL -BE LL BE US QUARRY ROCK accumulate within a catch basin. All catch basins and conveyance lines ' shall be cleaned prior to paving.' The cleaning operation shall not flush 4. SEDIMENT MUST BE REMOVED WHEN THE SEDIMENT IS 6" HIGH. sediment -laden water into the downstream system. ROCK CHECK DAM X-SECTION 5 IF THE FILTER FABRIC HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. 11. Stabilized construction entrances and wash pads shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures may be required to insure that all paved areas are kept clean for the duration of the project. y, 12. Wet season requirements as described in Appendix D, Section D.5.2"of SILT FENCE WI tIl LINEAR TRENCH the 1998 KCSWDM are in effect beginning October 1 through April 30. N . T. S. 13. Any permanent retention/detention facility used as a temporary settling basin shall be modified with the necessary erosion control measures and shalt provide adequate storage capacity. If the permanent facility is to function ultimately' as an infiltration or dispersion system, the facility shall not be used as a temporary settling basin. No underground detention tanks or vaults shall be used as a temporary settling basin. 14. Where ,seeding for temporary erosion control is required, fast germinating grosses shall be applied at an appropriate rate (i.e., annual ,or perennial rye applied at approximately 80 pounds per acre). 15 Where straw mulch for temporary erosion control is required, it shall be applied at a minimum thickness of two inches. 16. Management practices providing significant tree protection shall be provided per Section 22-1568 (C) (6) (A-G) of FWCC. CONSTRUCTION SEQUENCE: 1. Before any construction or development activity, a Preconstruction Meeting must be between the City of Federal Way, Ahe applicant and applicant's construction representative. 2. Flag clearing, limits. 3. Install stabilized construction entrance: 4. Install; filter fabric fence as indicated on plan. 5. Install catch basin protection to existing catch basins as shown on the plan. 6. Construct sediment trap: 7. Clear and grub areas of the site to be rough graded or filled. 8 Rough grade site and install storm conveyance system. Provide inlet ,protection where indicated. 9. Install remaining. utilities, dry wells and construct building. 10. Finish grade site and construct asphalt parking areas, access drives, sidewalks curbs and utters TEMPORARY EROSION CONTROL SEED MIX WEIGHT % PURITY % GERMINATION CHEWINGS OR RED FESCUE 40 98 90 FESTUCA RUBRA VAR. COMMUTATA OR FESTUCA RUBRA ANNUAL OR PERENNIAL RYE 40 98 90 LOLIUM MULTIFLORUM OR LOLIUM PERENNE REDTOP OR COLONIAL BENTGRASS 10 92 85 AGROSTIS ALBA OR AGROSTIS TENUIS WHITE DUTCH CLOVER 10 98 90 TRIFOLIUM REPENS APPLICATION RATE SHALL BE 120 LBS PER ACRE TEMPORARY EROSION CONTROL SEED MIX TABLE g WET SEASON PROVISIONS: 11. Complete site stabilization in accordance with landscape plans. All of the following provisions for wet season construction are detailed in the 12. Construct detention pond and install outlet pipes and storm filter. referenced sections. These requirements are listed here for the convenience of the designer and the 13. Clean storm drainage system, on and off site, of all sediment and ; reviewer. debris. 1. The allowed time that a disturbed area can remain unworked without 14. Remove temporary erosion control facilities when site is completely cover measures is reduced to two days, rather than seven (Section D.4.2): stabilized. 2. Stockpiles and steep cut and fill slopes are to be protected if unworked for more than 12 hours (Section D.4.2). 3. Cover materials sufficient to cover all disturbed areas shall be stockpiled. on site (Section. D.4.2). 4. All areas that .are to be unworked during the wet season shall be seeded within one week of the beginning of the wet season (Section 0). 5. Mulch is required to protect all seeded areas (Section 0). 6. Fifty linear feet of silt- fence (and the necessary stakes) per acre of disturbance must be stockpiled on site (Section D.4.3.1) 7. Construction road and parking lot stabilization are required for all sites unless the site is underlain by coarse -grained soil (Section D.4:4.2). 8. Sediment retention is required unless no offsite discharge is anticipated for the specified design flow (Section D.4.5). 9. Surface water controls are required unless no offsite discharge is anticipated for the specified design flow (Section 0). 10. Phasing and more conservative BMPs must be evaluated for construction activity near surface waters _(Section:D.5.3). 11. Any runoff generated by dewatering shall be treated through construction of a sediment trap (Section D.4.5.1) when there is sufficient space. or by releasing the water to a well -vegetated, gently sloping area. Since pumps are used for dewatering, it may be possible to pump the sediment -laden water well away from the surface water so that vegetation can be more effectively utilized for treatment. A straw bale filter shall be placed around the discharge from the dewatering, pump. if there is not space for a sediment trap or 25 feet of suitable vegetation, other filtration methods shall be required consistent" with KCC 9. 12. : 12. The frequency of maintenance review increases from monthly to weekly (Section D.5.4). 1998 King County Surface Water Design Manual, .Appendix D, page D-42 (SIDE VIEW) DITCH SLOPE CHECK DAM SPACING 0 - 5% 150' 5 - 10% 100' > - 10% 50' TYPICAL INTERCEPTOR DITCH W/ROCK CHECK DAM N.T.S. STABILIZED CONSTRUCTION ENTRANCE N.T.S. 4 1' MIN. OVERFLOW MIN. DISCHARGE TO STABILIZED 1' MIN. CONVEYANCE, OUTLET OR 3.5'- 1' MIN S ., ;ar. _..-:.. , ;v...- LEVEL SPREADER FLAT BOTTOM .1.5' MIN. RIPRAP 2"-4" ROCK NOTE: 3/4"-1 1 /2" WASH GRAVEL TRAP MAY BE FORMED BY BERM OR BY GEOTEXTILE ` PARTIAL OR COMPLETE EXCAVATION CROSS SECTION N.T.S. 6' MIN. 1' MIN. DEPTH OVERFLOW SPILLWAY 11, 1' MIN. DEPTH NATIVE SOIL OR 2" - 4 ROCK COMPACTED BACKFILL\\/// 1' MIN: DEPTH GEOTEXTILE 3/4" - 1.5" WASHED GRAVEL SEDIMENT TRAP OUTLET N.T.S. M'AftTENANCE STANDARDS 1. SEDIMENT SHALL BE REMOVED FROM TRAP. WHEN IT REACHES 1 FOOT IN DEPTH. 2. ANY DAMAGE TO THE TRAP EMBANKMENTS OR SLOPES SHALL BE REPAIRED. SEDIMENT TRAP N.T.S. 10> ROAD /GRADE j/5. - 4" MIN. DEPTH ROCK (4" MIN. FACE) 1 0" ROAD CROSSING SWALE N.T.S oR S p DALEY-MORROW- 726 AUBURN VI WASy O�IF AUBURN, WASHING •` 4- PHONE: (253)333-2200 Q 28352 �o ��� ® ENGINE 0�� S 1 E � L AL incorpora-�+ te I P IGNED & DATED APPROVED DATE -B:\PR0JEC7S\11-105 LAMBS. GATE CHURCH\DWG\11105ENG.OWG L0 0 r r T APPROVED DATE PERMrr No. J O 0 co L / O J J 181.7LF 12" CONC @ 17.167 REV NO. DATE DESCRIPTION APPROVED ER S. PO DALEY-MORROW-POBLETE, AUBURN INC. CLIENT LAMB'S GATE PRESBYTERIAN CHURCH �0 WAY NORTH 02 AUBURN, PHONE: (253)33-22001NGFAX: (2TON 530)333-2206 29850 18TH AVE. S, FEDERAL WAY, WA 98003 PHONE No. (253) 632-9101 Q Q PROJECT _ LAMB'S GATE PRESBYTERIAN CHURCH 8s ENGINEERING -SURVEYING CONSTRUCTION PLAN SIONA LAND PLANNING L F�G in cc, rpo ro tad DRAWN By ASP SCALE 1 = 20' DRAwiNc 11105ENG _ SHEET P IGNED k DATED - - _ APPROVED ASP DATE JUL. 22, 2011 Joey 11 —105 B:\PROJECTS\ 11- 105 LAMBS CATE CHURCH\DWC\ 1110.5FNG. r:= Lo O f f.l 450 d3�� 440 430 DATUM ELEV 425.00 460 450 DATUM ELEV 42500 O r d- i =uj 1 PVI ELEV = 454.�O N M EXISTING f A.D. _ -10.5 +Lo f GRADE f K=9.52 w 100, VIC i > GRADE f j ww i 1.507- PVI STA = 0+88.16 ii 00 LqLo PVI ELEV = 442. 5 ,�� + - A.D. - 9.00 � K=2.78 00 ' 6iw i 25' VC l Co r. ori v > m m p o +� f 1, CSI +� UU / 750 -- >> m W,? /00 / �2°°� ' +o 1 » m ® 4.55% FROM CB NO. 6 TO EX. CB f i oo U) z ROSSING I.E. = 439.41 17 N Lo L-- +I0 u ►- z I I 440 4.9 LF 12" SD i i 0.50% FROM CB f N 0RGMNG 0. 1 TO CB NO. 2 I E = 43 I � i .0 i d 000 NIA �I� �1� �16 i0 In �fvcid � 111.0 � �ito Lo �iL DRIVEWAY SCALE: 1 = 20' (H.), 1" = 5'(V.) / jG G CB - TYPE _ -- LF 12 CONC C3 011 RIM = 464.06 224.8 I.E. = 461.46(E) I.E. = 460.76(W) EXISTING / CB - TYPE GRADE RIM = 457 29 PROPOSED / o ��'�� - 1.E. = 454.09(W) GRADE G F 1 5 � - ii 12" SD CROSSING I.E. = 433.45 EX. CB - TYPE 1 EX. RIM = 4 8.78 I (ADJUST TOGRADE) I EX. I.E. = 43 .68(E) --- I.E. = 435.95 N} 430- I.E. - 435.68 S} I Ln Ln LC) u Lo O i � O C.0 N cD N (D O � cC r d- d- d d d d d �t PROFILE ALONG EXISTING STORM DRAIN PIPE SCALE: 1" = 20' (H.), 1,> = 5,(V.) :.• 450 DATUM ELEV 440.00 N PVI STA = 6+44.50 PVI ELEV = 455.63 I An = Ann PVI STA = 6+59.50 PVI ELEV = 456.83 A.D. = -6.00 w r [- K = 5.00 15' ou VC . Ve oo N N +In � EXISTING cow G ADE w riN a ¢- `t (nw PROPOSED -lyN 1 U)t;i A > ww I V) z m m / I f I f I �i cfl c Lo Ln 6+00 7+00 PARKING LOT 1 SCALE: 1" = 20' (H.), 1" = 5'(V.) PVI STA = 8+44.50 PM STA = 8+59.50 PVI ELEV = 451.16 1 15, PVI ELEV = 452.97 E PRO 450 440 DATUMELEV 435.00 Lo d- A.D. = 7.00 15, VC A.D. _ -7.00 460- VC �,�� lam= 2:14 1 1 N M W p +ro Lo +�F +� ISTING 00 0 �� GRAnE I �LiJ > U U > N z > wj Ld 0°m uj f 5•p0 - ROSED GRADE - 2.00% i 440 rfj 00 Lo Ln Ln `t Ln 8+ 00 9+00 PARKING LOT 2 SCALE: 1" = 20' (H.), 1" = 5'(V.) DALEY-MORROW-POBLETE, INC. ER S PO WASy 6� 726 AUBURN WAY NORTH AUBURN, �Q bF Q WASHINGTON 98002 �y F PHONE: (253)333-2200 FAX: (253)333-2206 BENCHMARK CITY OF FEDERAL _WAY BM NO 2166-37 SOUTHWEST CORNER PSPL VAULT 50 FEET± NORTH OF 28352 ENGINEERING - SURVEYING ® SOUTH 356TH STREET, 35 FEET± EAST OF FOURTH AVENUE. Fss/STEM LAND PLANNING ELEVATION=304.207 (NGVD-29) 'ONA G�� L �\v incorporated STAMP NOT VALID UNLESS SIGNED do DATED - APPROVED DATE MRMrr NO. im 450 8.\PR0JECTS\11-105 LAMBS GATE CHURCH\DWG\17105ENG.DW0 L0 O r- DRAINAGE NOTES: 1. Proof of liability insurance shall be submitted to the City prior to the Preconstruction Meeting. 2. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with WSDOT 7-02.3(1). This shall include leveling and compacting the trench bottom, the top of foundation material, and required pipe bedding, to a uniform grade so that the entire pipe is supported by a uniformly dense unyielding base. 3. Steel pipe shall be galvanized and have Asphalt Treatment #1 or better inside and outside. 4. All drainage structures, such as catch basins and manholes, not located within a traveled roadway or sidewalk, shall have solid locking lids. All drainage structures associated with a permanent retention/detention facility shall have solid locking lids. 5. All catch basin grates shall conform to CFW Drawing Numbers 4-1, 2, 3, 4 or 5. 6. All driveway culverts located within the right of way shall be of sufficient length to provide a minimum 3:1 slope from the edge of the driveway to the bottom of the ditch. Culverts shall have beveled end sections to match the side slopes. 7. Rock for erosion protection of ditches, channels and swales, where required, must be of sound quarry rock, placed to a depth of one foot and must meet the following specifications: 4"-8" rock/40%-70% passing; 2"-4" rock/30%-40% passing; and —2" rock/10%-20% passing. Installation shall be in accordance with KCRS Drawing Number 51 or as amended by the approved plans. Recycled asphalt or concrete rubble shall not be used. 8. Lots not approved for infiltration shall be provided with drainage outlets (stub —outs). Stub —outs shall conform to the following: A. Each outlet shall be suitably located at the lowest elevation on the lot, so as to service all future roof downspouts and footing drains, driveways, yard drains, and any other surface or sub —surface drains necessary to render the lots suitable for their intended use. Each outlet shall have free —flowing, positive drainage to on approved stormwater conveyance system or to an approved outfall location. B. Outlets on each lot shall be located with a five—foot high, 2 x 4 stake marked "Storm". The stub —out shall extend above surface level, be visible and be secured to the stake. C. Pipe material shall conform to underdrain specifications described in KCRS 7.04 and, if non—metallic, the pipe shall contain wire or other acceptable detection. D. Drainage easements are required for drainage systems designed to convey flows through individual lots. E. The applicant/contractor is responsible for coordinating the locations of all stub —out conveyance lines with respect to the utilities (i.e. power, gas, telephone, television). F. All individual stub —outs shall be privately owned and maintained by the lot homeowner. MAINTENANCE INSTRUCTIONS FOR FULL INFILTRATION MAINTENANCE INSTRUCTIONS FOR BASIC DISPERSION YOUR PROPERTY CONTAINS A STORMWATER MANAGEMENT FLOW CONTROL BMP (BEST YOUR PROPERTY CONTAINS A STORMWATER MANAGEMENT FLOW CONTROL BMP (BEST MANAGEMENT PRACTICE) CALLED "LIMITED INFILTRATION," WHICH WAS INSTALLED TO MITIGATE THE MANAGEMENT PRACTICE) CALLED "BASIC DISPERSION,- WHICH WAS INSTALLED TO MITIGATE THE STORMWATER QUANTITY AND QUALITY IMPACTS OF SOME OF THE IMPERVIOUS SURFACE ON THE STORMWATER QUANTITY AND QUALITY IMPACTS OF SOME OF THE IMPERVIOUS SURFACES ON YOUR PROPERTY. LIMITED INFILTRATION 1S A METHOD OF SOAKING RUNOFF FROM IMPERVIOUS AREA PROPERTY. BASIC DISPERSION IS A STRATEGY FOR UTILIZING ANY AVAILABLE CAPACITY OF (SUCH AS PAVED AREAS AND ROOFS) INTO THE GROUND. INFILTRATION DEVICES, SUCH AS ONSITE VEGETATED AREAS TO RETAIN, ABSORD, AND FILTER THE RUNOFF FROM DEVELOPED GRAVEL FILLED TRENCHES, DRYWELLS, AND GROUND SURFACE DEPRESSIONS, FACILITATE THIS SURFACES. THIS FLOW CONTROL BMP HAS TWO PRIMARY COMPONENTS THAT MUST BE PROCESS BY PUTTING RUNOFF IN DIRECT CONTACT WITH THE SOIL AND HOLDING THE RUNOFF MAINTAINED: (1) THE DEVICES THAT DISPERSE RUNOFF FROM THE DEVELOPED SURFACES AND (2) LONG ENOUGH TO SOAK MOST OF IT INTO THE GROUND. TO BE SUCCESSFUL, THE SOIL THE NATIVE VEGETATED AREA OVER WHICH RUNOFF IS DISPERSED. CONDITION AROUND THE INFILTRATION DEVICE MUST BE ABLE TO SOAK WATER INTO THE GROUND FOR A REASONABLE NUMBER OF YEARS. DISPERSION DEVICES THE INFILTRATION DEVICES USED ON YOUR PROPERTY AS INDICATED ON THE PLAN ARE THE DISPERSION DEVICE USED ON YOUR PROPERTY AS .INDICATED ON THE PLAN ARE SPASH DRYWELLS. THE SIZE, PLACEMENT, AND COMPOSITION OF THE DEVICES AS DEPICTED BY THE BLOCKS. THE SIZE, PLACEMENT, COMPOSITION, AND DOWNSTREAM FLOWPATHS OF THE DEVICE AS PLAN AND DESIGN DETAILS MUST BE MAINTAINED AND MAY NOT BE CHANGED WITHOUT WRITTEN DEPICTED ON PLAN AND DESIGN DETAILS MUST BE MAINTAINED AND MAY NOT BE CHANGED APPROVAL EITHER FROM THE CITY OF FEDERAL WAY OR THROUGH A FUTURE DEVELOPMENT WITHOUT WRITTEN APPROVAL EITHER FROM THE CITY OF FEDERAL WAY OR THROUGH A FUTURE PERMIT FROM THE CITY. DEVELOPMENT PERMIT FROM THE CITY. INFILTRATION DEVICES MUST BE INSPECTED ANNUALLY AND AFTER MAJOR STORM EVENTS TO THE DISPERSION DEVICE MUST BE INSPECTED ANNUALLY AND AFTER MAJOR STORM EVENTS TO IDENTIFY AND REPAIR ANY PHYSICAL DEFECTS. MAINTENANCE AND OPERATION OF THE SYSTEM IDENTIFY AND REPAIR ANY PHYSICAL DEFECTS. WHEN NATIVE SOIL IS EXPOSED OR EROSION SHOULD FOCUS ON ENSURING THE SYSTEM'S VIABILITY BY PREVENTING SEDIMENT -LADEN FLOWS CHANNELS ARE PRESENT, THE SOURCES OF THE EROSION OR CONCENTRATED FLOW NEED TO BE FROM ENTERING THE DEVICE. EXCESSIVE SEDIMENTATION WILL RESULT IN A PLUGGED OR IDENTIFIED AND MITIGATED. CONCENTRATED FLOW CAN BE MITIGATED BY LEVELING THE EDGE OF NON-FUNCTIONING FACILITY. IF THE INFILTRATION DEVICE HAS A CATCH BASIN, SEDIMENT THE PERVIOUS AREA AND/OR REALIGNING THE SPLASH PAD. ACCUMULATION MUST BE REMOVED ON A YEARLY BASIS OR MORE FREQUENTLY IF NECESSARY. PROLONGED PONDING AROUND OR ATOP A DEVICE MAY INDICATE A PLUGGED FACILITY. IF THE VEGETATED FLOWPATHS DEVICE BECOMES PLUGGED, IT MUST BE REPLACED. KEEPING THE AREAS THAT DRAIN TO INFILTRATION DEVICES SWEPT AND CLEAN WILL ENHANCE THE LONGEVITY OF THESE DEVICES. THE VEGETATED AREA OVER WHICH RUNOFF IS DISPERSED MUST BE MAINTAINED IN GOOD FOR ROOFS, FREQUENT CLEANING OF GUTTERS WILL REDUCE SEDIMENT LOADS TO THESE DEVICES. CONDITION FREE OF BARE SPOTS AND OBSTRUCTIONS THAT WOULD CONCENTRATE FLOWS. j j ROOF DOWNSPOUT: roof downspout SERVES UP TO 700 S.F. building OF ROOF AREA BUILDING 50' MIN. VEGETATED FLOW PATH SPLASH BLOCK a flow roof downspout PLAN VIEW NTS catch basin or yard drain (see plan) 12'X12' hole filled with 1 2" - 3" washed drain rock O DOWNSPOUT EXTENSION roof downspout mark center of hole with 1" capped PVC overflow or other means building flush with surface splash block topsoi -, ROOF DOWNSPOUT SPLASHBLOCK N.T.S.D 0 1' min. flow fine mesh scree min 4" dia. PVC pipe �o MAINTENANCE INSTRUCTIONS FOR NON —VEGETATED PERMEABLE catch basin LQ(��� min. 4.6g PAVEMENT (yard drain) � 12' X 12' � for new building sides of ho 0,C hole filled with�o min. 6.9 for existing building lined with 10o 1 Z" - 3" washed 0� YOUR PROPERTY CONTAINS A STORMWATER MANAGEMENT FLOW CONTROL BMP (BEST filter fabric 0 drain rol MANAGEMENT PRACTICE) CALLED "PERMEABLE PAVEMENT," WINCH WAS INSTALLED TO MINIMIZE 15' min. THE STORMWATER QUANTITY AND QUALITY IMPACTS OF SOME OF THE PAVED SURFACES ON YOUR PROPERTY. PERMEABLE PAVEMENTS REDUCE THE AMOUNT OF RAINFALL THAT BECOMES RUNOFF BY ALLOWING WATER TO SEEP THROUGH THE PAVEMENT INTO A FREE —DRAINING GRAVEL OR min. V above seasonal SAND BED, WHERE IT CAN BE INFILTRATED INTO THE GROUND. high groundwater table THE TYPE OF PERMEABLE PAVEMENT USED ON YOUR PROPERTY IS POROUS ASPHALTIC DRY WELL CONCRETE. SECTION THE AREA COVERED BY PERMEABLE PAVEMENT AS DEPICTED ON THE PLAN AND DESIGN DETAILS NTS MUST BE MAINTAINED AS PERMEABLE PAVEMENT AND MAY NOT BE CHANGED WITHOUT WRITTEN APPROVAL EITHER FROM THE CITY OF FEDERAL WAY OR THROUGH A FUTURE DEVELOPMENT PERMIT FROM THE CITY. DRYWELL INFILTRATION SYSTEM PERMEABLE PAVEMENTS MUST BE INSPECTED AFTER ONE MAJOR STORM EACH YEAR TO MAKE SURE IT IS WORKING PROPERLY. PROLONGED PONDING OR STANDING WATER ON THE PAVEMENT N. T. S. SURFACE IS A SIGN THAT THE SYSTEM IS DEFECTIVE AND MAY NEED TO BE REPLACED. IF THIS OCCURS, CONTACT THE PAVEMENT INSTALLER OR THE KING COUNTY WATER AND LAND RESOURCES DIVISION FOR FURTHER INSTRUCTIONS. A TYPICAL PERMEABLE PAVEMENT SYSTEM HAS A LIFE EXPECTANCY OF APPROXIMATELY 25—YEARS- TO HELP EXTEND THE USEFUL LIFE OF THE SYSTEM, THE SURFACE OF THE PERMEABLE PAVEMENT SHOULD BE KEPT CLEAN AND FREE OF LEAVES, DEBRIS, AND SEDIMENT THROUGH REGULAR SWEEPING OR VACUUM SWEEPING. THE OWNER IS RESPONSIBLE FOR THE REPAIR OF ALL RUTS, DEFORMATIONS, AND/OR BROKEN PAVING UNITS. DALEY-MORROW-POBLETE, INC. �O ER S. P� WASy B� 726 AUBURN WAY NORTH AUBURN, WASHINGTON 98002 PHONE: (253)333-2200 FAX: (253)333-2206 28352 Fss�oNA �o ��� ENGINEERING - SURVEYING 101 �� LAND PLANNING L incorporated STAMP NOT VALID UNLESS SIGNED & DATED PERMIT NO. APPROVED DATE B:\PROJECTS\11-. 105 LAMBS. GAr£ CH1JRCH\DW0\11105 Lo 0 r r T A Ftow INLET PLAN VIEW STANDARD OUTLET RISER FLOWKIT: 40A SECTION A A A JTLET D. MANHOLE 1CTURE O.D. �U w_ xa w� a IL > 2L z m U I- W O ox0 = v~ 5' DRAFT STORMFILTER DESIGN NOTES STORMFILTER TREATMENTCAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (3). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 3 CARTRIDGES. 045 MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.0 CFS. IF THE SITE CONDITIONS EXCEED 1.0 CFS AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 2.3' 1.8' SPECIFIC FLOW RATE (gpm/so 2 gpm I 1 gpmM2 2 gpm 1 gpMfftZ 2 gpm 1 gpm' CARTRIDGE FLOW RATE (gpm) 22.5 1 1125 15 7.5 10 5 FRAME AND COVER (DIAMETER VARIES) N.T.S. SITE SPECIFIC DATA REQUIREMENTS STRUCTURE ID CB #3 WATER QUALITY FLOW RATE (crs) 0.04 CFS PEAK FLOW RATE (crs) 0.50 CFS RETURN PERIOD OF PEAK FLOW (yrs) 100 YR. # OF CARTRIDGES REQUIRED 3 _ CARTRIDGE FLOW RATE 7.50 MEDIA TYPE (CSF, PERLITE, ZPG, GAC, PHS 2PG PIPE DATA: I.E. MATERIAL DIAMETER INLETPIPE#1 432.19 PVC 12" INLET PIPE #2 WA WA WA OUTLET PIPE 432.30 PVC 12" RIM ELEVATION 440.50 ANTI -FLOTATION BALLAST WIDTH HEIGHT N/A WA NOTES/SPECIAL REQUIREMENTS: " PER ENGINEER OF RECORD GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH () ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH CONSTRUCTION PRODUCTS REPRESENTATIVE. www.contechcpi.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. 5. STRUCTURE SHALL MEET AASHTO HS20 AND CASTINGS SHALL MEET AASHTO M306 LOAD RATING, ASSUMING GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION 6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 39 SECONDS. 7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq it). INSTALLATION NOTES 1. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. 2. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFTAND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES PROVIDED). 3. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. 4. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). 5. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB AND SAND COLLAR IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR- 6. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. A��V�uTCAv® ice.►0i' i r�r! SFMH48 CONSTRUCTION PRODUCTS INC. STORMFILTER www.contach-epi.can 9025 Centre Pointe Dr., Suite 400, West Chester, OH 45069 STANDARD DETAIL 800 338-1122 513-645-7000 513-645-7993 FAX -MO��I iii I(- -M -LEVELING PAD 1 /8" X 3/4" X 2 1 /4" L/2- FOR SLOT DETAIL SEE 23 3/4" DWG- N0. 2-013 PLAN m n NOTES: ELEVATION 1. SELF -LOCK VANED GRATE MANUFACTURER SUBJECT TO APPROVAL BY ENGINEER. 2. USE WITH TWO LOCKING BOLTS 5/8"-11 NC STAINLESS TYPE 304 STEEL SOCKET HEAD (ALLEN HEAD) CAP SCREWS 2" LONG. NOTE SLOT DETAIL 3. MATERIAL IS DUCTILE IRON ASTM A536 GRADE 80-55-06. 4. "OUTFALL TO STREAM DUMP NO POLLUTANTS" MAY BE LOCATED ON BORDER AREA. VANED GRATE DWG. NO. 4-10 N.T.S. APPROVED DATE 1 #3 BAR HOOP 2 #3 BAR HOOPS #3 BAR EACH CORNER #3 BAR EACH SIDE :tea 0 D FRAME AND GRATE C� 30" NOTES: Z s 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ASTM C478 (AASHTO M 199) & C890 UNLESS OTHERWISE SHOWN ON 5 PLANS OR NOTED IN THE WSDOT/APWA STANDARD SPECIFICATIONS. 6 6" RISER SECTION 2. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED WIRE } FABRIC HAVING A MIN. AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY TO ASTM A497 (AASHTO M 221). WIRE FABRIC SHALL NOT BE PLACED IN KNOCKOUTS. 3. ALL REINFORCED CAST -IN -PLACE CONCRETE SHALL BE s• so, CLASS 4000. 2c 5, 4, PRECAST BASES SHALL BE FURNISHED WITH CUTOUTS OR KNOCKOUTS. KNOCKOUTS SHALL HAVE A WALL THICKNESS 5 OF 2" MIN. ALL PIPE SHALL BE INSTALLED IN FACTORY �I PROVIDED KNOCKOUTS. UNUSED KNOCKOUTS NEED NOT BE GROUTED IF WALL IS LEFT INTACT. 12" 12" RISER SECTION S. KNOCKOUT OR CUTOUT HOLE SIZE IS EQUAL TO PIPE OUTER f DIAM. PLUS CATCH BASIN WALL THICKNESS. 6. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX. DIAM. OF 20 KNOCKOUTS MAY BE EITHER ROUND OR "D" SHAPE. &0 <1,4 Mi 7. THE MAX. DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5'-0". 8. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2"/FT. 9. CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE WITH STANDARD SPECIFICATIONS AND MEET THE STRENGTH REQUIREMENTS OF FEDERAL SPECIFICATION RR-F-621D. MATING SURFACES SHALL BE FINISHED TO ASSURE PRECAST BASE SECTION NON -ROCKING FIT WITH ANY COVER POSITION. OtF�THERBASE� AT THE TOP 10. FRAME AND GRATE MAY BE INSTALLED WITH FLANGE DOWN OR CAST INTO RISER, 11. FOR CATCH BASINS IN PARKING LOTS REFER TO WSDOT/APWA STANDARD DWG. B1-b. 12. EDGE OF RISER OR BRICK SHALL NOT BE MORE THAN 2" FROM VERTICAL EDGE OF CATCH BASIN WALL. #3 BAR EACH WAY CATCH BASIN TYPE 1 DWG. NO. 4-1 N.T.S. ER DALEY-MORROW-POBLETE, INC. S �O 726 AUBURN WAY NORTH WAS# AUBURN, WASHINGTON 98002 Q�� PHONE: (253)333-2200 FAX: (253)333-2206 Q- ,pF 28352 �p ��� ENGINEERING SURVEYING Fss�NA L T � LAND PLANNING / ncorporated STAMP NOT VALID UNLESS SIGNED do DATED Br\PROJECTS\I1-105 LAMBS GATE CHURCH\DWC\L110� L0 O r T 5/8" ORIFICE z VERTICAL GRATE EL. = 437.40 L g • 4.0' MIN. OPENING - 0 1-3/8" ORIFICE__ N EL. = 436.55 a 90' in o e `t to 54.4 LF - 12" SD SHEAR GATE 20.7LF - 12" SD p @ 0.50% (TYP,) @ 0.50% FROM POND PLAN OUT TO STORM FILTER N SCALE: 1" = 2' Z 12, I.E. = 432.30 PVC o ° I.E. = 432.19 NOTES: PIPE SUPPORT(S): Yx.090 GAUGE--"" AUGE RISER i BOLTED OR IMBEDDED 2" IN WALL `v 1. METAL PARTS: CORROSION RESISTANT. AT MAX. 3' SPACING. MIN. 1 SUPPORT 8 GALVANIZED PIPE PARTS TO HAVE ASPHALT ° z 2� (MAX.) 7 2" CLASS "B" ASPHALT CONCRETE 1 1/2" COMPACTED DEPTH CRUSHED SURFACING TOP COURSE 2 1/2" COMPACTED DEPTH CRUSHED SURFACING BASE COUSE GRAVEL MAY BE REQUIRED ACCESS SECTION N.T.S. 450 440 430 DATUM ELEV 4,20.00 In 6' CHAINLINK FENCE j 156.00 5' MAX. ROCKERY ALONG EAST SIDE 1 EXISTING 1"[ NCH = 51.00 GRADE i / 6' CHAINLINK FEINCE / / PROPOSED 0' GRADE rY BERM = 439.0 _ - _TO_P OF POND =439.00 - - - - - 5.7' CONC. Rd MAX. W.S. -�_ --- EL. = 438.00 --- ------ BY OTHERS. SI1 PLANS. TOP -( / l 2' BENCH EL. = 432.30 _ - CONTROL STRU TURE BOT. EL. = 431.80 CV SEED TAIL Lf 6" SEDIMENT I 43 STORAGE 1 1 f co co L-- -- I -- - ------1- - - - --1- - 22+00 V PLAN DETENTION STORAGE REQUIRED = 13,040 cu.ft. SCALE: 1' = 10' DETENTION STORAGE AVAILABLE 13,698 cu.ft. DETENTION STORAGE PROVIDED = cu.ft. REMOVEABLE STANDPIPE * RIP RAP SHALL BE IN ACCORDANCE WITH SECTION WATERTIGHT 9-13.1 OF THE WSDOT/APWA STANDARD SPECIFICATIONS. COUPLING RIP RAP TO BE REASONABLY WELL GRADED WITH ROCK GRADATIONS AS FOLLOWS: 6' „ MAXIMUM STONE SIZE 8" MEDIUM STONE SIZE 6" MINIMUM STONE SIZE 2" _ EMERGENCY OVERFLOW 6„ TOP OF BERM / MW.S. EL.=438.25 AX. ROUND SOLID LOCKING COVER EL.=439.00 xxx MARKED "DRAIN" RIM EL.=440.50 ///��///��/// ///� PLATE WITH ORIFICE (SIZE AS INDICATED) ROD (TO 3//\\ - 4 MIN o _.._tREACH BE WITHIN 1' //� E>' - I �' �� 16" MAX. OF RIM) z �� ///� ///� ///� /// 4 ELBOW DETAIL III N. T. S. 2'-6 MIN. ° 0 4' (MIN.) LONG VERT. GRATE SPACE BARS @ 4" O.C. DO I NOT OBSTRUCT OPENING 0.5' MIN. DEPTH ROCK (*) EL. = 438.00 ,o a 438.00 SEDIMENT POND SPILLWAY DETAIL N.T.S. EMBANKMENT NOTES: 1. POND BERM ENBANKMENTS MUST BE CONSTRUCTED ON NATIVE CONSOLIDATED SOIL FREE OF LOOSE SURFACE SOIL MATERIALS, ROOTS AND OTHER ORGANIC DEBRIS. 2. POND BERM EMBANKMENTS GREATER THAN 4 FEET IN HEIGHT MUST BE CONSTRUCTED BY EXCAVATING A KEY EQUAL TO 50% OF THE BERM EMBANKMENT CROSS -SECTIONAL HEIGHT AND WIDTH. 3. THE BERM EMBANKMENT SHALL BE CONSTRUCTED OF COMPACTED SOIL (95% MINIMUM DRY DENSITY, MODIFIED PROCTOR METHOD PER ASTM D1557), PLACED IN 6-INCH LIFTS, WITH THE FOLLOWING SOIL CHARACTERISTICS PER THE UNITED STATES DEPARTMENT OF AGRICULTURE'S TEXTURAL TRIANGLE: A MINIMUM OF 20% SILT AND CLAY, A MAXIMUM OF 60% SAND, A MAXIMUM OF 60% SILT, WITH NOMINAL GRAVEL AND COBBLE CONTENT. 23+00 SECTION A -A SCALE: 1" = 20' (H.), 1" = 5' (V.) J � 1' BENCH 450 440 EX. 8" SS - DATUM ELEV 430.00 S I 5 EX. BLDG. AINING WALL E STRUCTURAL 438.00 W W I I �- - - 6'I CHAINLINK FENCE / -- 6 MAX. �'.y�� ALONG ROCKERY - NORTH SIDE i EXISTING GRADE 5' MAX. MOCKERY ry' ALONG SOUTH SIDE pppEp G App'' 1' BENCH 1' BENCH i _ TOP OF POND = 439.00 VMAX. W. S EL. = 438.00 ROCK LINING 5 7' CONC. RETAINING WALL PROTECTION BY OTHERS. SEE STRUCTURAL S_E NOTE PANS. TOP = 438.00 2' BENCH EL. = 432.30 ------ 1 SD PIPE BOT.EL.=431.80 1..=432.30 6" SEDIMENT STORAGE rni Ln 06! Ln d- 26+00 SECTION B-B SCALE: 1" = 20' (H_), 1" = 5' (V.) PE%U NO. APPROVED DATE N OTES: TREATMENT 1. 5/8-0 - STAND. GALV. DALE I -MORROW-POBLr_ I E (NC. 2. FRAME &LADDER OR STEPS OFFSET SO ORIFICE 0 STEEL LADDER/STEPS (TYP.) 1. ROCK LINING SHALL BE 1' THICK WITH THE FOLLOWING GRADATION: ��ER S p� 726 AUBURN WAY NORTH A. CLEANOUT GATE IS VISIBLE FROM TOP. N PASSING 8-INCH SQUARE SIEVE: 100%P �� WAAUBURN, WASHINGTON 98002 B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND PASSING 3-INCH SQUARE SIEVE: 40 TO 60% MAXIMUM �� '„ PHONE: (253)333-2200 FAX: (253)333-2206 CLEANOUT GATE. a ° ° PASSING 3/4-INCH .SIEVE: 0 TO 10% MAXIMUM a 3. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE, OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1 /4". ELEVATION 28352 0 �� ENGINEERING -SURVEYING CONTRO%L_j STR UCT URE SCALE: 1 = 2 ��ss� c s T `` ® LAND PLANNING Tll E 11-�4 �NA� C incorporated SCALE: AS NOTED STAMP NOT VALID UNLESS SIGNED do DATED OR/ 11105 - o"" _ 12 . .,� ..,.,- sPPn.....U..�PPoa...mo. ...�......��— ii...i...P.47PPPL47P�lPP��PP UU.i►P.UU�i000UVP.uv, .� >�PPiaPi.PPS...P��>U�Pi�i�i=i�.4�P�Yi.iUUUViUU.PPi�.P� P P��7PiUPP.P� \ �i..�,_.�'�N�iZ4r�4 I I ►®7� ■�, ``�PPPiU�Pi.QP�UUO.�.�►�PPPi�iU.>�i�tlPPiUVPv!..PPP.� � ..imw►o.� ..... s ;_w = a� --—v�=�':. ..uma.�o..ic i�. OL' � -•— - �: � ��•-T�.�.......O.nO...PJUu.O�000UUUUU� -�� � �P�..T.ijT1.�.m.Pm�.U...P..P1.0 . P.U.P.V�PPP.�; � ����� ( �ri�DipmPiU..�o..iUrPPiiu�PPi000..U.iUUU���Pw� 1 ",VIVA, PiP�i�PP.�P�U.ni.P.�Pii...i�iU...PP��Pi- � �.UU��....U�i v�UU.>U.PPPiU�PPP►�P.000UUU.P�UUU.P�U.i.P.L�PP..P....PPPOP....IU�PPP..PPPi►.P��: UUU.PiM.U.Pa�� - - _ MA �,.�.i. �.i�'+_ uii7p.P.S�su�i�ari47��.TA ►UU.i►Pio..iS:Pii�o.� ( - • 1........1..U.PP11AVAl y*..rA" ....Od.U.bPn...�C woolm S �� �� i�t.i�% '� �� �• + -. I l�.P.� 0.7...U0`►P�P1U .� I .U.P..�O..UU.P....►.- .��a�l .lei..•��..iiii.i.iUU.�U.�.>.�..►q.�.iL�00L \ TYPE III BUFFER: 7,185 S.F. TOTAL LANDSCAPE AREA: 19,457 S.F. LANDSCAPED SLOPE: 2,533 S.F. TOTAL LAWN AREA: 6,896 S.F. PARKING LOTS: 2,943 S.F. LAWN AREA AS A % OF TOTAL. 35.44% LAWN AREAS: 6,896 S.F. PARKING LOT LANDSCAPE: SIGNIFICANT TREES: THE SITE CONTAINS 12 SIGNIFICANT TREES REQUIRED: 20 S.F./STALL OR 800 S.F. MIN. WITH A CALIPER OF 12" OR GREATER. 9 TREES II PROVIDED: 2,943 S.F. ARE TO BE SAVED, 3 TREES ARE TO BE REMOVED, SAVING 75% OF SIGNIFICANT TREES. REPLACEMENT TREES ARE NOT REQUIRED. I I II �PRESENCE OF EXISTING _SEWER LINE MAY REQUIRE MODIFICATION OF PLANT SELECTIONS STAMP NOT VALID UNLESS SIGNED & DATED 40 REV. NO. DATE DESCRIPTION APPROVED DALEY-MORROW-POBLETE, INC. CLIENT LAMB'S GATE PRESBYTERIAN CHURCH 726 AUBURN WAY N_ 29850 18th AVE. S., FEDERAL WAY, WA. 98003 AUBURN, WASHINGTON 98002 PHONE: 253-333-2200, FAX: 253-333-2206 PHONE No. (253)632-9101 PROJECT LAMB'S -GATE PRESBYTERIAN CHURCH ENGINEERING - SURVEYING PRELIMINARY LANDSCAPE PLAN Q D LAND PLANNING i rl Co rpo ro ted DRAWN RY LM SCALE 1„ c 20' DRAWING 11105ENG T 11 'VI SHEET --------- APPROVED ,ASP °ATE JUL. 22, 2011 1 JOBS` 11105 DE_ 12 Rr,PR0JEC7S\ 11- 105 1AMRS GATE CHURCH\DWG\ 11105ENG.OWG 450 STJ CB NO. RIP ..I 6 LF 12" SD CAD 1 C FROM CB IN 430 DATUM ELEV 420.00 — ----r — - a I.E. - 432.30 (OUT) TYPE 11 // 54. LF 1 PVC SD .50% 429.29 \ / —� X — — — — — —� .79(NE) / .79(SE) STA. 10+94.57, 35.05' RT. 3.99(N) / CB NO. 4 - TYPE II, 48" (STORM FILTER) 18TH AVENUES. - PLAN SCALE: 1 " = 20' GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. ` I STA. 12+50.37, 18.02' RTC CB NO. 6 TYPE I 450 W/SOLID LOCKING LID RIM = 443.00E 10+91.15, EDJUS440043 (CONNECT 0 j 27.10' RT. STA. 11 +51.94, 21.36' RT. � EXISTING SD PIPE) �- — _ 'c > --" ypE-l1 �8" W/SOLID EX. RIM = 438.78 w OCKING LID I (ADJUST TO GRADE) = 435.00, = 429.10 EX. I.E. = 435.68(E) I.E. = 435.95(N) EXISTING GRADE -� I 8B.5� F 12 CPEP @ 2.72% AT C/L I _ 43.5 5-�- 440 E. Sp ®4 � I 1 50.1 LF 12" SD 0 0.50% FROM CB NO. 8 TO CB NO. 2 CB - TYPE I PV 150% 6LF �0/0 S�Sp ®5' STA. 11+66.08, 14196' LCB N0. 8, TYPE I RT. 1(NO SUMP) RIM = 445.22 b. 4/ ` I.E. = 441.92(N) WITH THROUGH CURB INLET VANED GRATE _ �38.50 I I. E. = 441 .82(S) I.E. = 435.50 STA. 11 +08.35, 270 7' RT. CB NO. 7, TYPE GRATE = 435.75 I.E. = 432.75 23.3 LF 12" - - REPLACE b o XISTING 59.6 LF 12" CONCRETE I PIPE @ 11.71% WITH 66.0 LF 1 CONCRETEPIPE @ 6.53%. MAINTAIN EXISTING HORIZONTAL. MATCH EXISTING I.E. AT WEST ND._ N O ni Ln N Oto 11 +00 -12+00 18TH AVENUES. - PROFILE SCALE: 1" = 20' (H.), 1" = 5'(V.) 13+00 PERMIT NO. APPROVED DATE I I 1 V.ILIVV SHEET oaf/ 11105 OF --_ 2 __-- B: \PROJECiS\ 71 - 105. IAMBS GATE CHURCH\DWG1 11105ENC.OWG �- RIGHT—OF—WAY LINE 2' - �6, RESIDENTIAL 6" 10 —0 MIN. SIDEWALK \� 20'-0" MAX.\�\�� COMM./INDUSTR. 2'� \ �\ : 6 •. \, i \\! \%� �\ \ PLANTING STRIP, IF ANY. � 30' — 0" 2—LANE "•" \ 40' — 0" 3—LANE�\ \\\�\ 0' SEE CURB DETAIL DRAWING 3-4 EXPANSION JOINT RIGHT—OF—WAY LINE 6" VARIE 3' MIN VARIES NOTES: F o.oa / p 02 /� , 1. COMMERCIAL/INDUSTRIAL DRIVEWAYS WIDER THAN 40' MAY �/ =• / j� BE APPROVED BY THE ENGINEER CONSIDERING TRAFFIC •/�/�//,/ SAFETY AND NEEDS OF THE ACTIVITY SERVED. ALL COMMERCIAL/INDUSTRIAL DRIVEWAYS SHALL HAVE AN MATCH EXISTING EXPANSION JOINT LOCATED MID -WIDTH. SEE KCRS SEC. 3.04. 1 \ >,\/, ��������i��/��\// DRIVEWAY GRADE 2. SEE SEC. 3.2.13 AND CURB DETAIL DRAWING 3-4. 2" CSTC for RESIDENTIAL 3. CONCRETE SHALL BE CEMENT CONC. CLASS 3000 WITH 4% TO 6% CEMENT CONCRETE DRIVEWAY 6" THICK AIR ENTRAINMENT. 4" CSTC for COMMERCIAL 4. FULL DEPTH EXPANSION JOINT IF DRIVEWAY WIDTH IS 15' OR GREATER. SECTION A —A CURB & G UTTER SECTION DRIVEWAY N-T.S. 6' EXPANSION JOINT 5" * 0.021Ff./FT. - 0.05 FT./FT 2 CEMENT CONCRETE SIDEWALK V-6" * NOTE: TOP OF LIP AT DRIVEWAYS. CEMENT CONCRETE CURB & GUTTER NOTES: 1. SEE SEC. 3.04 K.C.R.S. FOR JOINT REQUIREMENTS. CURB DETAILS 60' R/W C /L�30' 30' ' NEW 32' EX. PVMT. $' af 4' 6, , L.S. ilVt�,ix � PVMT. SAWCUT 1' (TYP.) , 1, 6" 2� 2% EXIST. SIDEWALK 2" C.S.T.C: 0.25' COMPACTED DEPTH, H.M.A. (HOT MIX ASPHALT) 0.17' THICK CRUSHED SURFACING TOP COURSE (5/8" MINUS) COMPACTED 0.5' THICK CRUSHED SURFACING BASE COURSE (1-1/4" MINUS) SUBGRADE (TYP.) ADDITIONAL TREATMENT MAY BE REQUIRED CURB AND GUTTER PER CITY DEPENDING ON SOIL CONDITIONS STANDARD DTL. 6-6(a) NOTE: ALL SUBBASE MATERIALS SHALL BE COMPACTED TO 95% OF ASTM D-1557 TYPICAL STREET SECTION -18TH AVENUE S. SCALE: 1„ = 10' (H.), 1" = 5' (V ) VARIES SIDEWALK 2" CRUSHED SURFACING TOP COURSE VARIES PLANTER STRIP I SIDEWALK AS REQUIRED 318" EXPANSION VIIAIT - 1 /'I" OA11111C FOR CURB & GUTTER USE DETAIL 3-4 I � FOR CURB & GUTTER 2" CRUSHED SURFACING TOP COURSE USE DETAIL 3-4 CONSTRUCTED ONE PER RADIUS, AT MIDPOINT OF CURB NOTES: 1. FOR JOINTS AND SCORING, SEE FEDERAL WAY STANDARD FOR SIDEWALK SPACING, EXPANSION JOINTS, AND SCORE MARKS. 2. CONCRETE DRIVEWAYS REQUIRE A MINIMUM DEPTH OF 6". 3. WHEN CI : 'KED WITH A 10 FOOT STRAIGHTEDGE, GRADE SHALL NOT DEVIATE MORE THAN 1 /8 INCH AND ALIGNMENT SHALL NOT VARY MORE THAN 1/4 INCH. SIDEWALK D WG. NO. 3 -1 2 N.T.S. PERMIT NO. APPROVED DATE C:\YKUJt CI}\7l-IUS. LAMLYS GAlt UHUKCH\UWC,'\ll1U5LNG.VWG 460 450 440 430 DATUM ELEV 425.00 — — EXISTING GRADE PROPOSED— GRADE — — 460 3/4" W.M. OR 3/4" W.M. FOR ANEW CHURCH AND 3/4" 3/4" W.M. FOR DDCV IRRIGATION. �& STA. 2+70 .68, 2.00' LT. 459 INSTALL. 1 - 8"x6" TEE (FLxMJ) 00 N f- 1 - 8" ADAPTER 1 - 8" BLIND FLANGE I o 15 LF 6 [ 1, CL 50 N (MIN. 36 COVIJR) '' 50 x - „ 2 - CON61 THRUST BLOCK 00 V) z 23.0 LF 8 SEPARATE , WATER METER APPLICATION REQUIRED N f D.I., CL 50 TO ACTIVATE DDCVA (PER LUD STD.) + 1 o I (MIN. 36" 10' MIN. BTVHEEN THE DDCVA AND ANY TREE I1- � ��, %-nn' COVER) SD <F- INSTALL:44 0 I z 1 �- 8"X6„ TEE (MJxFL) EX. 12" WATER AIN 12 A SD 13[ 1 - 6 G.V. (FLxRJ) 5 LF 6" D.I., CL. 50 1 - 5-) /4" MVO F.H. ASSY. (FIELD- VERIFY) 8" SS INSTALL: 1 - 12"X8" T PING TEE (TAPxFL) , 1 - 8" G.V. ( - xMJ) I I ' 3-0-- i r� d N 00 � Cn - i 't Lo Ln Lo Lo 23.0 LF E AY 8" D.I. /02-102628 20041027900001 .. LOT 3 a \ —I Ljl STA. 2+ 0.68, 2.00' LT. INSTALL: ,\ 1- 8 x6 TEE (FLxMJ) 1 - 8" ADA�TER 1 8 BLIND FLANGE 15 LF 6" D.I.,\CL. 50 i 6" DDCVA, CON . VAULT 2 CONC. THR�IST BLOCK f SEPARATE WATER METER APPLICATION REQUIRED TO ACTIVATE DDCVA (PER LUD S*.) , 10' MIN. BETWEEN THE DDCVA AND, ANY TREE d 94 / ((� 460 d ' 1 m i 'D I `� �t cflCD 1 I EX. 10' DRAINAGE ESMT. (REC. 6625431)00 Lu �I I a N 460 ? 1 10 { I I REV. 3-14-07, REV. 5-29-08) BURIED UTILITIES IN AREA CALL BEFORE YOU DIG 1-800-424-5555 EXISTING UTILITIES SHOWN ARE FROM THE BEST AVAILABLE INFORMATION AND NO GUARANTEE IS MADE AS TO THE EXACT SIZE, TYPE, LOCATION OR DEPTH. APPROVED . DATE PEFUIT No. SCALE: 1" = 20' (H) 1" = 5'(V ) B-\PR0JECTS\11-105 LAMBS GATE CHURCH\DWG\ 11 105ENG.DWG