Loading...
10-101132 (2)VICINITY MAP 111AW SITE LOCATION.. tS u DRIVING DIRECTIONS STARTING FROM VERIZON BELLEVUE OFFICE: TAKE 1-90 W TOWARD SEATTLE, TAKE EXIT 10 TO MERGE ONTO 1-405 S TOWARD RENTON, TAKE THE EXIT ONTO 1-5 S TOWARD PORTLAND, TAKE EXIT 143 FOR S 320TH ST TOWARD FEDERAL WAY, TURN RIGHT AT S 320TH ST, TAKE THE 2ND LEFT ONTO 23RD AVE S, CONTINUE ONTO S 324TH ST, TURN LEFT TOWARD PEBBLE BEACH CIR, TURN RIGHT AT PEBBLE BEACH CIR, TAKE THE 2ND RIGHT ONTO MERION WAY, TURN RIGHT AT BURNING TREE BLVD, TURN RIGHT AT OAKLAND HILLS BLVD, ARRIVE AT SITE ON THE LEFT. APPROVAL / SIGN OFF APPROVED BY: DATE SIGNATURE SITE ACQUISITION ZONING R.F CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED x � ............... N.• C 1 'i..nf% FEDERAL WAY, WA KING COUNTY PROJECT INFORMATION APPLICANT / LESSEE: VERIZON WIRELESS 15900 SE EASTGATE WAY, SUITE 231 BELLEVUE, WA 98008 PROJECT ENGINEER: CORNERSTONE ENGINEERING, INC. 16928 WOODINVILLE REDMOND ROAD N.E. SUITE 210 WOODINVILLE, WA 98072 MARK W OLSON, P.E. PH: (425) 487-1732 FAX: (425) 487-1734 CODE INFORMATION: ZUNINC3 ULA66IF-IUA I IUN: BUILDING CODE: CODE INFORMATION: CONSTRUCTION TYPE: OCCUPANCY: JURISDICTION: PROPOSED BUILDING USE RM3600 2006 IBC 2005 NEC TELECOMMUNICATIONS UNOCCUPIED CITY OF FEDERAL WAY UNMANNED TELECOMM. SITE LOCATION: (BASED ON NAD 83 LATITUDE: 47018'18.8" N LONGITUDE: 122018'8.44" W TOP OF STRUCTURE: 120'-0" AGL BASE OF STRUCTURE: 394.00' AMSL PROJECT AREA: TOWER WORK GENERAL INFORMATION: 1. TRAFFIC IS UNAFFECTED. 2. NEW SIGNAGE IS PROPOSED. 3. ADDITIONAL IMPERVIOUS AREA IS PROPOSED. PROJECT CONSULTANTS: REALCOM ASSOCIATES 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007 PHONE: (425) 274-4444 FAX: (425) 274-4449 PROPERTY OWNER: BELMOR HOLDINGS LTD 1571 BELLEVUE AVE #210 W VANCOUVER BC CANADA V7V1A6 TOWER/POLE OWNER: AMERICAN TOWER CORPORATION 116 HUNTINGTON AVE, 11 FLOOR BOSTON, MA 02116 PH: (617) 375-7500 SITE NAME: CEEJAY SITE NUMBER: 82935 SITE ACQUISITION: OLIVIA BAZYLEWICZ (425) 274-4444 EXT. 118 obaz@realcomassoc.com LANDUSE / PERMITS: SARAH TELSCHOW (425) 274-4444 EXT. 114 steischow@realcomassoc.com PROJECT MANAGER: JULEI HINTY (425) 274-4444 EXT. 128 PARCEL N-WiTIBER"" 1621049037 AREA A OF 2,732,954 SQ. FT. (62.74± ACRES) NEW IMPERVIOUS AREA: 0 PREVIOUS PERMIT APPROVALS: SEP 95-0012 & UPR 95-0011 PROJECT DESCRIPTION: THIS PROPOSAL IS TO MODIFY AN EXISTING TELECOMMUNICATION FACILITY WHICH INCLUDES THE FOLLOWING: ADDITION OF A 2'0 MICROWAVE DISH WITH MOUNTING HARDWARE AT THE 110'-0" LEVEL TO AN EXISTING ±120-FOOT HIGH STEEL MONOPOLE. DRAWING INDEX DWG. DESCRIPTION NO. T-1 TITLE SHEET G-1 GENERAL NOTES A-1 SITE PLAN A-1.1 ENLARGED SITE PLAN A-2 EXISTING & PROPOSED SOUTH ELEVATIONS A-3 CONSTRUCTION DETAILS LEGAL DESCRIPTION SE 1/4 OF NW 1/4 & PORS OF SW 1/4 OF NE 1/4 & OF NW 1/4 OF SE 1/4 LY WLY OF PRIM ST HWY NO 1 LESS POR TO KING COUNTY SC 533169 SUBJ TO TRAN LN ESMT LESS CO RD APPWWF�1' PLAN City.Or` B UTILITY COMPANIES POWER PUGET SOUND ENERGY (800) 321-4123 TELEPHONE QWEST COMMUNICATIONS (800) 475-7526 Verl onwireless We never stop working for you. 3350161 st AVE SE / MS #221 BELLEVUE, WA 98008 R EAL C O M :PLANS PREPARED BY: 4 c* COi:qNeiRsirONE n, c _ 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@cornerstone-engr.com : PROJECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY r ISSUED FOR: � L REV:=DATE: =DESCRIPTION:=BY:=CK:J A02-09-10 FOR CONSTRUCTIONJRF MWO Qq 02-04-10 FOR REVIEW LJS MWO `DRAWN BY: CHK.:-APV.: LJS I JDG MWO CURRENT ISSUE DATE: 02-22-10 r LICENSURE: EXPIRES 02/15/12 DRAWING INFORMATION: DRAWING TITLE: LnPA\A/Wr- Kil IRARGR- ' T� . 1 0 CEI JOB NUMBER: 10-567 E I E FL MAR 18 z010 CITY OF FEDERAL WAY CDS GENERAL NOTES: CONCRETE NOTES: STRUCTURAL NOTES: 1. THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER 1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI-318. 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR OR SEWER SERVICE. REVIEW PRIOR TO FABRICATION. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC 2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION. (NO 2006 SECTION 1905 AND ACI 301. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. 2. STRUCTURAL STEEL DESIGN, FABRICATION, PAINTING AND ERECTION (INCLUDING FIELD WELDING, HANDICAP ACCESS IS REQUIRED). HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) TYPE OF CONSTRUCTION 28 DAY STRENGTHS SHALL BE BASED ON THE AISI "SPECIFICATIONS FOR THE DESIGN, FABRICATION, AND ERECTION OF 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES (fC) STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE PER MONTH, BY VERIZON WIRELESS TECHNICIANS. A. SLABS ON GRADE WITH IBC 2006 CHAPTER 17, BY A QUALIFIED TESTING AGENCY DESIGNED BY THE CONSULTANT. TOPPING SLABS THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST 4. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. CONCRETE PIERS 3000 psi RESULTS. 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. B. ALL STRUCTURAL CONCRETE 4000 psi 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 6. ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE C. CONCRETE FOUNDATIONS 3000 psi TYPE OF MEMBER LATEST VERSION. CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II UNLESS NOTED OTHERWISE. A. WIDE FLANGES ASTM A992, Fy = 50 ksi 7. THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE B. PLATES, SHAPES, ANGLES, AND RODS ASTM A36, Fy = 36 ksi SCOPE OF THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM 3. THE CONSTRUCTION MANAGER SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND C. SPECIAL SHAPES AND PLATES ASTM A572, Fy = 42 ksi WILL BE PAID FOR EXPENSES RESULTING FROM FAILURE TO DO SO. PROCEDURES OF CONCRETE PLACEMENT. D. PIPES ASTM A53, Fy = 35 ksi E. STRUCTURAL TUBING ASTM A500, Fy = 46 ksi 8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE 4. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN F. ANCHOR BOLTS ASTM A307 CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE AIR -ENTRAINED AGENT CONFORMING TO ASTM C260, C494, C618, C989 AND C1017. TOTAL AIR G. CONNECTION BOLTS ASTM A325 CONSTRUCTION MANAGER. CONTENT SHALL BE IN ACCORDANCE WITH TABLES 1904 OF THE IBC 2006. 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER ASTM A123 / A123M-00. 9. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE 5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy = TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES. 60,000 psi. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 5. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND VERIZON WIRELESS STANDARDS AND 40, fy = 40,000 psi. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PRE 10. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS, ETC. IS INDICATED AS PROPOSED CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF QUALIFIED WELDS (AS DEFINED BY VERIZON WIRELESS) SHALL BE USED. WELDING OF GRADE 60 LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON -SITE CONSTRUCTION MANAGER MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. PRIOR TO THE START OF WORK. SPECIFIED IN AWS D14 ARE SUBMITTED. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. 11. ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE 6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. PRE -CONSTRUCTION CONDITION OR BETTER. 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS 6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON 12. INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE A MINIMUM AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2-0". LAP ADJACENT MATS OF WELDED WIRE FABRIC THE PLANS. PROVIDED MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL OF 72 HOURS NOTICE TO CONSULTANT. A MINIMUM OF 8" AT SIDES AND ENDS. FRAMING SHALL CONFORM TO THE AISI "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS." 13. REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. OF THE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" 0) AND SHALL HAVE A THE CONSTRUCTION MANAGER. 8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy = 60,000 MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. ALL ASSEMBLIES ARE TO BE TIGHTENED IN psi. ACCORDANCE WITH "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490", JUNE 14. OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION 30, 2004. FOR BEARING -TYPE CONNECTIONS, AS A MINIMUM, THE BOLTS SHALL BE TIGHTENED TO OF WORK AND ACCEPTANCE. PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER 9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS A "SNUG; TIGHT" CONDITION. A "SNUG TIGHT" CONDITION IS DEFINED AS THE TIGHTNESS THAT VERIFYING THAT THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND SPECIFICALLY SO DETAILED OR APPROVED BY THE ENGINEER OF RECORD. EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW AUTHORITIES HAVING JURISDICTION. IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: WRENCH. 15. PROVIDE VERIZON WIRELESS WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER DATE OF ACCEPTANCE, FOR THE COMPLETE INSTALLATION. REPAIR OR REPLACE ANY DEFECTS A. FOOTINGS AND OTHER UNFORMED 3" 8. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8"0 ASTM A307 BOLTS UNLESS ARISING DURING THIS PERIOD AT NO EXTRA COST TO VERIZON WIRELESS. SURFACES, EARTH FACE NOTED OTHERWISE. 16. NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED, WITHOUT WRITTEN B. FORMED SURFACES EXPOSED (#6 BARS OR LARGER) 2" 9. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE. APPROVAL FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT IN TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1 112" CONTRACTOR CORRECTING THE INSTALLATION AT THEIR EXPENSE. 10. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR C. SLABS AND WALLS (INTERIOR FACE) 3/4" APPROVED EQUAL. ABBREVIATIONS: 11. 12. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. ANCHOR BOLTS TO CONFORM TO ASTM A307. AFF ABOVE FINISHED FLOOR JT JOINT SPECIAL INSPECTIONS: AFG ABOVE FINISHED GRADE LAM LAMINATED AFS ABOVE FINISHED SLAB LF LINEAL FOOT ALUM ALUMINUM MANUF MANUFACTURER 13. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2006 SECTION 1704. AB ANCHOR BOLT MAX MAXIMUM AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. L ANGLE MECH MECHANICAL GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3,000 psi SOILS/GEOTECHNICAL: ARCH ARCHITECTURAL MH MANHOLE MINIMUM). ❑SHORING INSTALLATION AND MONITORING BTS BASE TRANSMISSION SYSTEM MM MILLIMETER ❑ OBSERVE AND MONITOR EXCAVATION BLDG BUILDING MIN MINIMUM ❑ VERIFY SOIL BEARING psf BEARING BM BEAM MISC MISCELLANEOUS ❑SUBSURFACE DRAINAGE PLACEMENT LEGEND AND SYMBOLS: BOT BOTTOM MPH MILES PER HOUR B.O. BOTTOM OF MTL METAL ❑VERIFY FILL MATERIAL AND COMP ACTION BOC BOTTOM OF CONCRETE NIC NOT IN CONTRACT ❑VERIFY CONDITIONS AS ANTICIPATED CHAIN LINK FENCE BOS BOTTOM OF STEEL NOM NOMINAL ❑PILE PLACEMENT (AUGER CAST/DRIVEN PILE) CJ CONTROL JOINT NTS NOT TO SCALE ❑OTHER q CENTER LINE OC ON CENTER CEDAR FENCE 13 CLG CEILING OD OUTSIDE DIAMETER REINFORCED CONCRETE: CLR CLEAR OH OVERHEAD POWER P P P ❑REINFORCING STEEL AND CONCRETE PLACEMENT CMU CONCRETE MASONRY UNIT OPNG OPENING TELCO T T T ❑PRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION COL COLUMN OPP OPPOSITE ❑BATCH PLANT INSPECTION CONC CONCRETE PCs PERSONAL COMMUNICATION SYSTEM POWER/TELCO T/P T/P T/P - T/P ❑SHOT CRETE CONST CONSTRUCTION R PLATE ❑GROUTING CONT CONTINUOUS PR PAIR COAX COAX COAX coax ❑OTHER CTR CENTER PSI POUNDS PER SQUARE INCH DIA / 0 DIAMETER PSF POUNDS PER SQUARE FOOT OVERHEAD POWER off off off off - STRUCTURAL STEEL: DTL DETAIL PT PRESSURE TREATED CENTERLINE ❑FABRICATION AND SHOP WELDS (E) EXISTING RAD RADIUS MERECTION AND FIELD WELDS AND BOLTING EA EACH RD ROOF DRAIN ❑OTHER EJ EXPANSION JOINT REINF REINFORCED/REINFORCING REVISION BUG 1 ELEC ELECTRIC/ELECTRICAL REQ'D REQUIRED EL ELEVATION RM ROOM EQ EQUAL RNV RIGHT OF WAY DETAIL NUMBER STRUCTURAL ALUMINUM: �i- ❑FABRICATION AND SHOP WELDS EW EACH WAY SCHED SCHEDULE ELEVATION VIEW ❑ERECTION AND FIELD WELDS AND BOLTING EXP EXPANSION SECT SECTION BUG - ❑OTHER EXT EXTERIOR SF SQUARE FOOT FD FLOOR DRAIN SIM SIMILAR SHEET NUMBER FIN FINISH SQ FT SQUARE FOOT STRUCTURAL MASONRY: FIN FLR FINISH FLOOR SS STAINLESS STEEL TOP OF ❑CONTINUOUS FLR FLOOR STD STANDARD ... ELEVATION EL 0'-0" ❑PERIODIC FTG FOOTING STL STEEL GA GAUGE STRUC STRUCTURAL ❑ GALV GALVANIZED TEMP TEMPORARY DETAIL NUMBER GYP GYPSUM THK THICK DETAIL BUG -- I --- SHEET NUMBER OTHER: GB GYPSUM BOARD T.O. TOP OF HM HOLLOW METAL TOS TOP OF STEEL HOR HORIZONTAL TOC TOP OF CONCRETE ANCHORING TO CONCRETE: HR HOUR TYP TYPICAL ❑BOLTS INSTALLED IN CONCRETE HT HEIGHT UNO UNLESS NOTED OTHERWISE SECTION BUG _ ❑POST -INSTALLATION ADHESIVE ANCHORS HVAC HEATING VENTILATION AIR CONDITIONING VERT VERTICAL C -- DETAIL NUMBER ❑POST -INSTALLATION MECHANICAL ANCHORS INSUL INSULATION W/ WITH -� - - SHEET NUMBER INT INTERIOR WWM WELDED WIRE MESH Vert Oft wireless We never stop working for you. 3350 161 st AVE SE / MS #221 BELLEVUE, WA 98008 PLANS PREPARED BY: 4 -� COFRNEFR51 NONE INC. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@cornerstone-engr.com PROJECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY ISSUED FOR: r REV:=DATE: =DESCRIPTION:-BY:=CK:� A02-09-10 FOR CONSTRUCTIONJRF MWO A02-04-10 FOR REVIEW LJS MWO DRAWN BY: CHK.: APV.:- LJS JDG MWO CURRENT ISSUE DATE: 02-22-10 � LICENSURE: W. O< o 32 IS��`G���� o `SS�ONAL EN vll EXPIRES 02/15/12 DRAWING INFORMATION: DRAWING TITLE: LnQnXAnnir_ nn innRP:Q- CEI JOB NUMBER: 10-56005 ni r)TP THIS IS NOT A SITE SURVEY. ALL PROPERTY BOUNDARIES AND ORIENTATION OF TRUE NORTH HAVE BEEN OBTAINED FROM A PLOT MAP AND PREVIOUS DRAWINGS PROVIDED TO CEI AND ARE APPROXIMATE. SITE PLAN 22x34 SCALE: 1" = 150'-0" ADJACENT ZONING USE: VACANT LAND IZONE: - --- -----_ SITE ACCESS ADJACENT ZONING USE: VACANT LAND Wiz" _ _ _ _ N890 18' 09" W _ 1306.24'-- CITY CENTER (CC) WINGED FOOT WAY � W O i _SEMINOLE LANE ;0)/ Wl X is c N \ o co W=1 YVA Y LO I� TL# 1621049037 - 1,684,465 SQ FT - o ' 38.67 ACRES TL# 1621049023 - N790 23' 49" W 60.00' 11x17 SCALE: 1" = 300'-0" / N89° 20' 17" W / 457.05' co o / rn I � / j Z / L---- N74° 15' 30" W 25.00' j zQ O I lr' r n I 4,� COLONIAL BLVD Li N890 21' 22" W 1338.23' TL#1441700000 I I I WIco flo - I ;c! S 330TH ST _ I� M � ----------- - -- zl tu, ` �l --- o / A-1,1 (E) 120' HIGH STEEL MONOPOLE I / / (E) CHAINLINK FENCED EQUIPMENT COMPOUND -- m N89017' 18" W 71.86' R = 11710.00 A = 02' 26' 37" L = 499.39' ADJACENT ZONING USE: VACANT LAND ZONE: CORPORATE PARK (CP-1) TL#1621049056 i Verl Oil wireless fiammmoffam We never stop working for you. 3350161 st AVE SE / MS #221 BELLEVUE, WA 98008 REALCOM PLANS PREPARED BY: 4 cal CORNr=FRsi'ONE INC_ 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@comerstone-engr.com PROJECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY L ISSUED FOR: LREV:=DATE:=DESCRIPTION: BY:=CK:_j A02-09-10 FOR CONSTRUCTION JRF MWO Q02-04-10 FOR REVIEW LJS MWO DRAWN BY: CHK.:-APV.:� IF LJS I JDG MWO CURRENT ISSUE DATE: 02-22-10 r LICENSURE: W. 04 �P OF �Sti�Ls'Q2 "Fss/ONAL t� G�, EXPIRES 02/15/12 DRAWING INFORMATION: DRAWING TITLE: LnQAIAnnir_ K11 innQr-:Q- V' V A• V 11\ V ' llVIV I L L I\. A� 1 0 CEI JOB NUMBER: 10-56005 (E) POWER METERS V/ (1 • v 1.A� l/" oQOCt oQ p � QBQ ggm tP(E) CARRIER ICE BRIDGE V, °goo°'0 °, 11 W/ (12) 7/8 O COAX (E) b°/ % o° 9° a° Q (E) CARRIER 3 x3 CONCRETE EQUIPMENT SLAB ;I. V (E) CARRIER ICE BRIDGE W/ (2) 3" 0 CONDUIT (E) i g� dd 8 o 0 () ASPHALT ACCESS ROE AD � f- (E) 11' WIDE ACCESS GATE W/ BARBED WIRE (E) MOBILE GENERATOR (COW) NLARGED SITE PLAN --- (E) WOO CURB -- (E) CARRIER 8'x12' CONCRETE EQUIPMENT SLAB — PROPOSED VERIZON 2 WIRELESS MW ANTENNA A-3 PROPOSED VERIZON WIRELESS 1 MW ANTENNA MOUNT A-3 °Dom 0 9 mo. 8 ol (E) 120' HIGH STEEL MONOPOLE on o ° o°o pa imp �°p QQ e90 q� ° Ggode �°.go�Oo °o D°��°U , o. os / c o ° o°'o6 00°09 o B�QaQ �° & 4 o o °Qa A o 0 / r%��e�° ° a°°e° ° p ° °d °O2 9ooB�o ° p�°4°°s 90 O�oocDo 1%/ /l °one °o° o �a � o, o o o `yam oo°ao q ° o Q .8 °D 9008. �o 0V os e °eo ° °ov a III °o°orb �8 ° o (E) VERIZON WIRELESS 12'x24' EQUIPMENT SHELTER o a O Q V ° �PoQ8o gAQ'o 0 oQ 0 b ° °0Qb $� a (E) LANDSCAPING (E) CHAINLINK FENCE W/ BARBED WIRE (E) LANDSCAPE WALL °.e �°ooB0000 a ° 00-7�,,o °o o e°Q °� ° Da b ;sue` 110-0 o 9°0 V % o ao6°v , o°�0 00 a Odo�o ° � ° o o�aoofl �o 0�' o II / / / / / / / / (E) CARRIER ICE BRIDGE W/ (18) 7/8" 0 COAX (E) (E) VERIZON WIRELESS ICE BRIDGE W/ (12) 7/8" 0 COAX (E) (6) 1 5/8" 0 COAX (E) (E) CARRIER 6'x10'-8" CONCRETE EQUIPMENT SLAB �wQ8Q p �66�o�1n4 gw � d it �O i7 °OpOo QD v�ip & "a 0o a°� q� d�Jt' o ° J Is. O4�;}/9 = z o E / O a (E) HIGHWAY SOUND WALL (E) GENERATOR CFI No d°�IIaQ �° 9 cf 0g�gge� i� �t ° G° b 9 °° oc7cG� D 8 o � I VerI 0n wireless We never stop working for you. 3350161 st AVE SE / MS #221 BELLEVUE, WA 98008 REALCOM PLANS PREPARED BY: 4 —�� COFtNwRsi NONE N c . 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@comerstone-engr.com JECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY ItU f-UK: CONSTRUCTION L. REV:= DATE: =DESCRIPTION: BY:=CK:J A02-09-10 FOR CONSTRUCTIONJRF MWO qQ 02-04-10 FOR REVIEW LJS MWO `DRAWN BY: CHK.:-APV.: LJS I JDG MWO CURRENT ISSUE DATE: 02-22-10 r LICENSURE: C r0,q� 0Ch'i,� 0•L cSS�ON�AL ENG` 2� Z;Zji. Q EXPIRES 02/15/12 'DRAWING INFORMATION: DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. 'DRAWING TITLE: ENLARGED SITE PLAN Altar_ Kil IAAQGP- A�l ■ l 0 CEI JOB NUMBER: 10-56005 .i. T n (Fl .qTFFI MONJOID01 F (0'-0" ASSUMED) PROPOSED SOUTH ELEVATION 22x34 SCALE: 1 /8" = 1'-0" 11 x17 SCALE: 1 /16" = 1'-0" /C\ \/CD17nkl \A/I CI CCC AAITCnIKIA /C\ \A/I0CI CCC AAITCAIKIA AGL G�R_ADE REF _ EL 394'-0" AMSL (0'-0" ASSUMED) 2 EXISTING SOUTH ELEVATION 1 22x34 SCALE: 1 /8" = 1'-0" 11 x17 SCALE: 1 /16" = V-0" r Ve► I On wireless We never stop working for you. 3350 161 st AVE SE / MS #221 BELLEVUE, WA 98008 REALCOM PLANS PREPARED BY: 4 cal CORNERSirONE N 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@comerstone-engr.com PROJECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY r ISSUED FOR: r REVZ DATE: =DESCRIPTION:=BY:=CK:� A02-09-10 FOR CONSTRUCTION JRF MWO qQ 02-04-10 FOR REVIEW LJS MWO DRAWN BY: CHK.:-APV.:� LJS JDG MWO CURRENT ISSUE DATE: 02-22-10 LICENSURE: DRAWING INFORMATION: DRAWING TITLE: LnPA\A/IN(, nII IAAPP:P- A�2 0 rCTEI JOB NUMBER: 10-56005 NOT USED 22x34 SCALE: NTS 11 x17 SCALE: NTS NOT USED 5 22x34 SCALE: NTS HD CHAIN MOUNT (SITE PRO "1" P/N DCH8) ISOMETRIC VIEW HD CHAIN MOUNT (OR APPROVED EQUAL) 22x34 SCALE: 1 1/2" = 1'-0" 11 x17 SCALE: 3/4" = 1'-0" 11 x17 SCALE: NTS 22x34 SCALE: NTS 11x17 SCALE: NTS CHAIN MOUNT KIT 4 1/2" O.D. PIPE (P/N P463) 4 1/2" O.D. PIPE (P/N P463) CHAIN MOUNT KIT (TYP 28" 0 3 MICROWAVE ANTENNA DETAIL 22x34 SCALE: 1 1/2" = 1'-0"1 11 x17 SCALE: 3/4" = 1'-0" TOP VIEW SIDE VIEW FRONT VIEW 2 i verl onwireless MINNOW We never stop working for you. 3350 161 st AVE SE / MS #221 BELLEVUE, WA 98008 REALCOM PLANS PREPARED BY: 4 cal COFtNERSi NONE N C. 16928 WOODINVILLE-REDMOND RD NE, SUITE 210 WOODINVILLE, WA 98072 PHONE: (425) 487-1732 FAX: (425) 487-1734 EMAIL: cei@comerstone-engr.com PROJECT INFO: SEA CEEJAY 2101 SOUTH 324th ST FEDERAL WAY, WA 98199 KING COUNTY L. ISSUED FOR: r REV:=DATE: =DESCRIPTION:=BY:=CK:� A02-09-10 FOR CONSTRUCTIONRUCTION JRF MWO �q 02-04-10 FOR REVIEW LJS MWO L DRAWN BY: CHK.:-APV.:- 11 LJS I JDG MWO CURRENT ISSUE DATE: 02-22-10 LICENSURE: DRAWING INFORMATION: DRAWING TITLE: LnQAXAnnif'Z nil IKAQ�D- A�3 0 CEI JOB NUMBER: 10-56005