Loading...
23-102460City or Federal Way Community Development Dept- 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Building - Commercial Permit #:23-102460-00-CO Inspection Request Line: (253) 835-3050 - Project.Name: TRADER JOE'S Project Address: 1758 S 320TH ST Project Description: BLUEBEAM - Loading door overhead 20' x 24' canopy. Parcel Number: 092104 9208 Owner Applicant Contractor Lender SEATAC VILLAGE SHOPPING CTR JIM TRUEBLOODB & T DESIGN & J HUGHES CONSTRUCTION INC SEATAC VILLAGE SHOPPING LLC ENGINEERING INC 312173RD PL SW CTR LLC 1121 SW SALMON ST FLOOR 5 PO BOX 595 BOTHELL WA 98012 1121 SW SALMON ST FLOOR 5 PORTLAND OR 97205 ISSAQUAH WA 98027 PORTLAND OR 97205 Census Category: 437 - Commercial alt / add / conversion Includes: #1 #2 #3 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) 0.00 0.00 0.00 0.00 Additional Permit Information Mechanical to be Included? ..................................... No Mechanical Work Valuation?_.. .......................... _ Is.this an Online or O.T.C. application? .................. No Plumbing to be Included? ........................................ No Total Valuation: 52,500.00 Plumbing Work Valuation? ..................................... 0 Number of Stories ................................................... I Permit for Building Shell Only? .............................. No Zoning Designation ................................................. CC-C '.tea =7-, 4.ch _ - do 61�:hY-Jo °e'�i,e%i 02 - Li F7 CONDITIONS: FIRE APPROVAL CONDITIONS: 1. Demolition and construction shall conform to the requirements of International Fire Code (IFC) Chapter 33. 2. Before you start work, schedule a Pre -Construction meeting with the Deputy Fire Marshal by calling 253-946-7318. 3. Automatic fire sprinkler(s) shall be installed under the exterior projection exceeding 4 ft. in width, unless the requirements of NFPA 13 - 8.15.7.2 thru 8.15.7.4 are met. 4: Separate permits and approvals are required for review or inspection of new fire protection or detection systems, or existing systems where any additions, alterations, or revisions are made. Obtain permits through the City of Federal Way. 5. Call 253-946-7318 to schedule your inspections. Please schedule your inspection at least 2 business days in advance. The fire marshal's office will call you back and set up an agreed upon time. Preferred inspection days are Tuesday through Thursday with limited inspection availability on Monday's and Fridays. PERMIT EXPIRES Wednesday, 27 December, 2023 Permit Issued on Friday, June 30, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: FGate- - . THIS CARD IS TO REMAIN ON -SITE CITY OF Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 23 102460 00 Address: 1758 S 320TH ST Project: SEATAC VILLAGE SHOPPING CTP FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE: TIIIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. ❑ Footings/Setback (4110) ❑ Foundation Wall (4115) ❑ Drainage/Downspout (4040) Approved to place ennere Approved to place concrete Approved to backfill By Date By Date By Date Q Re -steel (4215) 0 Slab/Concrete Floor (4255) ❑ Underfloor Framing (4285) Approved to place concrete or grout Approved to place concrete Approved to sheath floor By Date By Date By Date Floor Sheathing (4105) ❑ Shear Walls (4245) ❑ Roof Sheathing (4220) Approved to install flooring Approved to install siding Approved to install roofing By Date By Date By Date 10 Fire/Draft Stops (4095) scheduling a Framing inspection; ` ❑ Framing (4120) Approved FElectrical,Plumbing & Mechanical Rough -in Approved to insulate raft Stop inspections must be signed- B y Date f and approved. IBC 109.3.4 - - ByAW Date 12 Insulation (4150) 1s Gypsum Wallboard Nailing (4130) 14 Suspended Ceiling Grid (4265) Approved to install wallboard Approved to install mud & tape Approved to drop tile By Date By Date By Date 1 Final - S K F & R (4060) 1s Final - Planning ❑ Final - Building (4050) Approved PP Approved By Approved Date By Date By Date ❑ Final Electrical ❑ Right of Way ❑ Rough Electrical Approved Approved Approved By Date By Date By Date CITY OF Building Division Federal Eighth Avenue South FederalWay Federal Way, Fax 98835-6325 2609 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: ('�-� PERMIT#: "' 33- t0 Z)I IF YOU HAVE QUESTIONS CALL (253) 835- WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 35 050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. (90 «-Z" DATE 710 INSPECTOR DO NOT REMOVE THIS NOTICE Page of Kra z an &ASSOCIATES INC. GEOTECHNICAL ENGINEERING - ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION September 8, 2023 J. Hughes Construction, Inc. 312 173`d PI SW Bothell, Washington RE: Final Letter Trader Joe's #134 Canopy 1758 S 320`h Street Federal Way, Washington Dear Mr. McLean, KA Project No. 066-23244 Permit No: 23-102460 In accordance with your request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Reinforcing Steel Reinforced Concrete Structural Masonry e Structural Wood To the best of our knowledge, all work which has been tested and/or inspected has been found to be in general accordance with the approved plans and specifications, engineering revisions, and Chapter 17 of the 2018 International Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939-2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC William B. Throne Operations Manager bilithrone@krazan.com cc: toddm@ihuphesconstructioninc.com With Offices Serving the Western United States 825 Center Street, Suite A ■ Tacoma, WA 98409 ■ (253) 939-2500 • Fax: (253) 939-2556 •www.krazan.com Page 1 of 1 �dwan&Associates, Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection Field Report NO.: 06623244DFR8162023AT DATE: 8/16/2023 Set Count: CONTRACTOR: J.Hu hes Construction. INC PROJECT #: 06623244 PERMIT #: 23-102460 PROJECT: Trader Joe's #134 Cano .. INSPECTOR: Anders Tvedt LOCATION: 1758 S 320" Street JURISDICTION: City of Federal Way KA P.M.: WBT WEATHER: Clear TEMP: 65' F The Krazan representative arrived onsite to perform roof sheeting nailing and blocking. The representative meet with the contractor to discuss the scope of work. Roof Nailing: The area where the roof sheathing nailing inspection was performed on the canopy roof and for the blocking with connections bellow the roof. The diaphragm sheeting is exposure class-1, the rating of the sheeting is 32/16, and the thickness is 15/32" which follows onsite specifications and onsite plans. The roof nailing inspected follow boundary, edge, and field spacing per plan and nails follow the nail type stated in the onsite plans, specifications. The blocking connections observed follow type, spacing and nailing per onsite plans. I Reviewed I / ASTM Test By: ���""" #: Asset Number(s): To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Suoerintendent(Reo resentative: Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 The iefa"mn prvAW oo th apart is prcpucd for the esAoive nse of the client this reportmay tw! be rcpn,duwd is any forsost vdfhou! thcvrtiam pam lesion of the cheat and K.taan d: Asaeditcs. Tbs rrpwr :rdipttt ovr inspepor. ohxrvafioo and eea:iryj rptylp hawi c� site condilioos end wnuaetix ae:ivitics Tbis iafannarion is subj cf to urr:rw ptioria fia�Fsuhmitttl. 8y sie¢ing thia.cpdrt. nun [mpaior doh ndt accept responsibility for validity ofresulta. Thesameinfomrationhasbeenprovidedbyothersmsite. The test resuItt apply oilylathe specific Focatimu, and it®s ins*wed or=cd. Templar datc 411a= �Krazm&Assoclates, Inc. Geotechnical Engineering • Environmental Engineering Construction Testing and Inspection DATE: 8/8/2023 PROJECT #: 06623244 PROJECT: Trader Joe's #134 Canopy LOCATION: 1758 S 320thStreet KA P.M.: Bill Throne ❑ HIGH STRENGTH BOLTS 0 ANCHORS F71 Visual Bolts were not torque tested. Anchors were not load tested. 0 A visual inspection was performed on: oof Ledger Anchors - 30ea, 3/4" Dia Threaded Rod w/ 4-1/2" Embedment. PROPRIETARY ANCHOR & BOLTING INSPECTION REPORT NO.: 06623244HSBO80823-AB CONTRACTOR: J. Hughes Construction PERMIT #: 23-102460 INSPECTOR: Andrew Broughton JURISDICTION: City of Federal Way' WEATHER: Partly Cloudy TEMP: 1-0 Proof Load 0 Torque Test 0 Epoxy used Simpson StrongTie SET-XP Lo1#1000351868 EXP. 4110125 r - I NOTES U DISCREPANCIES 100 % COMPLETE an Field Representative Andrew Broughton arrived on -site as requested to perform Epoxy Anchor Inspection for the Root ,er Anchors - 30ea, 3/4" Dia Threaded Rod w/ 4-1/2" Embedment. Contractor used Simpson StrongTie SET-XP 1000351868 EXP. 4/10/25. The field representative met with the contractor and reviewed the approved plans and fications pertaining to today's Epoxy Inspection. Holes were blown, brushed, and blown to insure proper cleanliness. Jeff J. Hughes Construction, was informed of all observations. To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and regulatory requirements. Superintendent/Representative: X 8ultlug htspec ion Report Technician: Offices Serving the Western United States Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 - Tacoma (253) 939-2500 EffeU4-.121152020 ThiargmmeyWhe,epOdad in euyrmM wiUmdike mpQmiuimEfdmelim-dK—&A...iel®. TbEmdnmeh.p idedmd&mpul is pmpcmdit ecxdmhr=orlhedimL Ibis nepmt aAinla au iusl»d>oentim mauemng resorts hosedm sil—dihme,ud Epeaaear ecuvius lhie infmmeum4eubjmmnview piutp fimleobmineL Byu®uieg due rtpuL oor faspeeaedoee ool.olepllarywihiliry0r w11diryafrtzdls. IDe>,meinRMimWb=povidedbyahv i1e Theta>>esulu.Wy-1yw espedr.1..b-, aad itz.mpdda laird.