Loading...
01-101110 (2) City of Federal Way Sign Permit#:01 - 101110 - 00 - SG Community Development Services 33530 1st Way S ,..F4s1PralWAy WA 980(13-621n Ph:253.661.4000 Fax:253.661.4129 Inspection request line: 253.835.3050 Project Name: TOSCO CANOPY Project Address: 28718 MILITARY RD S Parcel Number: 552900 0230 *, Project Description: SGN-Install(2)new internally illuminated wall signs on existing gas station canopy. Owner Applicant Contractor TOSCO CORPORATION*TOSCO CORPORA RHL DESIGN GROUP BESTWORTH ROMMEL INC 72 CUMMINGS POINT RD RHL DESIGN GROUP 19818 74TH AVE NE STAMFORD CT 1550 140TH AVE NE ARLINGTON WA 98223 06902-7919 BELLEVUE WA 98005 (253)481-2656 Comprehensive Plan Designation Neighborhood Business Zoning Designation BN SI J i v ✓ r 4 / /gk5 /� Wall Signs I Registration# Sign Type Illuminated Sign Face Sign Face #of Sign Faces Building I Width(Ft.) Height(Ft.) Elevation A 01-0062 Cabinet Yes 3 3 1 North B I 01-0063 I Cabinet I Yes I 3 I 3 I 1 North CONDITIONS: Window signs are all signs located inside and affixed to a window and intended to be viewed from the exterior of a structure. Window signs are used to advertise products,goods or services for sale on-site,business identification,hours of operation,address,and emergency information. The area of window signs shall not exceed 25%of the window area. Pursuant to Federal Way City Code Section 22-1603(F),no sign may contain or utilize the following: (1)Any exposed incandescent lamp with a wattage in excess of 25 watts;(2)Any exposed incandescent lamp with an internal or external reflector;(3)Any continuous or sequential flashing device or operation;(4)Except for electronic changeable message signs,any incandescent lamp inside an internally lighted sign;(5)External light sources directed towards or shining on vehicular or pedestrian traffic or on a street;(6)Internally lighted signs using 800-milliamp or larger ballasts if the lamps are spaced closer than 12 inches on center; and(7)Internally lighted signs using 425-milliamp or larger ballasts if the lamps are spaced closer than six inches on center. Signs should be constructed and installed so that angle irons,guywires,braces and other structural elements are not visible. This does NOT apply to structural elements that are an integral part of the overall design.(FWCC,22-1602(A)) No sign shall project above the roofline of the exposed building face to which it is attached.(FWCC,22-1601(B)(2)) A separate electrical permit is required for any sign requiring electrical work. The electrical work must be approved by one of the city electrical inspectors. FINAL SIGN INSPECTION IS REQUIRED IN ORDER TO RECEIVE SIGN REGISTRATION NUMBER. PLEASE CALL 253-661-4140 TO SCHEDULE THE INSPECTION. PERMIT EXPIRES July 1,2002,IF NO WORK IS STARTED. Permit issued on January 2,2002 I hereby certify that the above information is correct and that the construction on the above described property the occupancy and the use will be in accordance with the laws,rules and regulations of the State of Washingt. the City of Federa;_.411r /� IA...— hh '\ Owner or agent •��� Date: V I 6-2 V 2 RECEIVED MAR 2 2 2001 am* G SIGN PERMIT APPLICATION EciErzFit_. c I l Y OF FEDERALi0 CATION;NUMBER: O L -J 0 1 1 L 0- 4/42 -4-5' BUILDING DEPTT. **The following is required information—Please print(in ink)or type** SITE ADDRESS: 28718 ,I I L I TAIL 1 RDA) ASSESSOR'S TAX/PARCEL#: 5 E 2 9.0 o - LEGAL DESCRIPTION OF SUBJECT PROPERTY(ATTACH SEPARATE DESCRIPTION IF LENGTHY): t.CT 23 o f The PLAT M I LI TA12Y ARMS TYPE OF PROJECT(Check all that apply): i PERMANENT o TEMPORARY I4 EW o ALTERATION o REFACE ❑EXEMPT NUMBER OF SIGNS APPLIED FOR WITH THIS APPLICATION: 2" PROJECT DESCRIPTION(Provide detailed description): ItSTALL Nev./ 3' DIA ��?b LAC7o $V(, ,S I h NAME W I TK c oM Et 67RAPF#1 Cs• BUSINESS/TENANT NAME: / v4 -0 SIGN OWNER: NAME: DAYTIME PHONE: Tosco MARKeTINCI CO . (Z174)766 - 2103 • MAILING ADDRESS()STREET ADDRESS;CITY,STATE,ZIP): � �/J\r` W /500 ►-( Pglrs'. e. P Etit 507 CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: EXPIRATION DATE: / / CONTRACTOR: NAME: — DAYTIME PHONE: MAILING ADDRESS(STRE ADDRESS;CITY,STATE,ZIP): EVENING PHONE: ( ) CITY OF FEDERAL WAY BUSINESS LICENSE NUMBER: FAX NUMBER:` I 4 CONTRACTOR'S REGISTRATION NUMBER: PIRATIONh DATE: (Copy required) APPLICANT: NAME: L DE5 I C7 C R,0Up, DAYTIMEH PHONE: MAILING ADDRESS(STREET ADDRESS;CITY, ZIP): ' � EVENING PHONE: �b -yb�7 /5 O I 0Jt �v6 HE STIR: loo 13etieVue,WA980(s( )FAX NUMBER: CONTACT FOR THIS PROJECT: (1,2s) 7L16 -613S40 o PROPERTY OWNER arAPPLICANT o CONTRACTOR E•M L ADDRESS: rH I akeld rl Ides ji cw i TYPE/PURPOSE OF EVENT: DATE OF INSTALLATION: DATE OF REMOVAL: TEMPORARY SIGN TYPE: o BANNER ❑INFLATABLE ❑PORTABLE ❑SEARCH LIGHTS/BEACON NUMBER OF EACH TYPE: PROPOSED NUMBER OF WALL SIGNS: Z PROPOSED NUMBER OF FREE STANDING SIGNS: 0 TOTAL ESTIMATED PROJECT COST: •� NUMBER OF TENANTS BUSINESS SPACES ON PROPERTY: PERMANENT FREE STANDING: ❑MONUMENT ❑OTHER ❑ PEDESTAL ❑POLE ❑TENANT DIRECTORY NUMBER OF EACH TYPE: PERMANENT BUILDING MOUNTED:❑AWNING ❑CABINET VCANOPY ❑CENTER IDENTIFICATION(CID) ❑CHANNEL LETTERS NUMBER OF EACH TYPE: Z. ❑MARQUEE a OTHER ❑PROJECTING ❑TENANT DIRECTORY NUMBER OF EACH TYPE: FREE STANDING SIGN SIGN AREA(SQ.FT.) ILLUMINATED?: REFACE? PART OF CID TOTAL SIGN BASE TYPE WIDTH X HEIGHT X#OF FACES NO/INT/EXT YES/NO SIGN? HEIGHT(FT) HEIGHT(FT) A B, C STREET FRONTAGE(Fr): BUILDING MOUNTED ILLUMINATED? SIGN AREA(SQ.FT.) BUILDING EXPOSED BUILDING SIGN TYPE NO/INTERNAL/EXTERNAL WIDTH X HEIGHT X#OF FACES = 'ELEVATION(N,S,E,W) FACE(SQ.FT.) A / I NTERNP i, 7. 07 J-I 216, �tq'rOeNAl- 7. 07 5 2 f b D E I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge,and further,that I am authorized by the/ owner of the above premises to perform the work for which the permit application is made NAME/TITLE: it,o 2 . DATE: IZ I GNATURE / //oc) NAME(Print) AIt.17 T D. LAKE PRjNT -rGR9rriccusc ONl1y ---{ A ZONING DESIGNATION: e1��( COMP PLAN DESIGNATION: J3 BUILDING MOUNTED SIGN 1 FREE STANDING SIGN AREA PERMITTED: l AREA PERMITTED: AREA PROPOSED: 1.04 AREA PROPOSED: LARGEST BUILDING FACADE: (A4•A STREET FRONTAGE: NUMBER OF SIGNS ALLOWED: NUMBER OF SINS ALLOWED: LAND USE APPROVER INITIALS: +� DATE: 4Is/di STRUCTURAL APPROVER INITIALS: \/�' DATE: REGISTRATION NUMBER:, o/. j2 REGISTRATION NUMBER: REGISTRATION NUMBER: N. 4_Q-706 REGISTRATION NUMBER: REGISTRATION NUMBER: REGISTRATION NUMBER: COMMUNITY DEVELOPMENT SERVICES•33530 FIRST WAY SOUTH•P.O.BOX 9718•FEDERAL WAY,WA 98063-6221•253-661-4000• FAX:253- 661-4129 SIGN PERMIT APPLICATION CHECKLIST ALL INFORMATION MUST BE PROVIDED BEFORE THE APPLICATION WILL BE ACCEPTED. Plans shall be of sufficient clarity to indicate the locations, nature and extent of the work proposed and show that it will conform to the provisions of the adopted Land Use and Uniform Codes and ordinances. Plan sheets must be 24"x 36". Minimum scale as indicated is required. 2(two)COMPLETE SETS of plans must be submitted with each application. COMPLETE PERMIT APPLICATION ISITE PLAN ELEVATION PLAN se-Scale (1"= 20') ee Location of ALL proposed signs, including refaces Et North arrow of Alpha labeling of each sign consistent with application ''Property lines and building footprint arr Location of all existing signs to remain ❑ Location of suite, if multi-tenant d Location of all existing signs to be removed o OTHER ITEMS APPLICABLE TO NEW OR ALTERED FREE-STANDING SIGNS ONLY BUILDING-MOUNTED SIGNS(S Figures 2A,2B,3,and 4) se/Scale (1/8"= 1,details 1/4"= 1') ai Dimensions of proposed signs /Location of existing and proposed signs rd Sign materials,color and illumination type or/Location of existing signs to be removed r/Alpha labeling of sign consistent with application VDimensions of existing signs to remain on each facade ri"Cross-section showing scaled width of sign: if canopy or awning,show entire building / including awning/canopy and color scheme i Dimensions of each building face or suite façade r Actual weight of sign 17 Calculated total building face square footage rd Method of attachment, size/type of connector AND /Calculated total area of individual letter, number,etc., OR 1a"Site-specific installation details(what sign is attached calculated total sign face square footage to in field), placement and construction FREE-STANDING SIGNS (See Figure 5 and 6) o Scale (1/8"= 1',details 1/4"= 1') o Calculated total panel area square footage, reface only o Sign materials and color o Sign base dimensions and finished grade o Sign face dimensions o Alpha labeling of sign consistent with application o Panel dimensions, reface only o OTHER ITEMS APPLICABLE TO NEW OR ALTERED FREE-STANDING SIGNS ONLY ti 5 ti 5i 5Si ti S iI " y, Wj 5° 5, %1 S % h 5 5; S. 5 ,,.5� ,ti fl1 ,5, ti $i g% ;. y Ws 0.� 3 W'Ell o coo 5' % F f_N 1 v QOn 1 G y Z CQ • M T-1 5 i 5j W'`,.'".... z W Woo }I Ca • C.) - z. Z CI 5� _ W '� Zo '5 - m 4 Z --t ~' W a y Q cnO Hc4EW-5: Z5 '. C rC F�-t H A a 3 5I .? CI Wr[ " xHZ cn a Wp C4,121r- E-4Tr0 s 4414 P. r H • P H I p CD ''` E.- H � 1 � �H C7 Z `,011 cn co a `-r c. W0 uw WrnA; U: U UW Wig '' • 4 I H _ 4 i z ;r H v 5� 1 2 3 1 4 1 5 1 6 7 18 9 10 19 12 13 1 14 15 16 1 17 18 DRAWING INDEX A-0 COVER SHEET 1 A-1 SITE PLAN M A-2 EXISTING CANOPY ELEVATIONS A-2.1 NEW CANOPY ELEVATIONS AND SIGNS Lt EXISTING LANDSCAPE PLAN CS-1 FRAMING, FOUNDATION & ELEVATION CS-2 TYPICAL SECTIONS AND DETAILS C06273 TYPICAL 76 DOME LOGO SIGN L --.. K ------------------------ G R K ---------- m� 0 0 vMrmANY ..........J '. ------------- Q i G )E A YNA'y y OFFri, GENERAL NOTES GENERAL DESCRIPTION PROJECT DESCRIPTION CONSTRuc1nON REP. Lg7,gNRLITAp�,rRDSN so 01-1011I0-sG � SIGN 1, CONTINUALLY POLICE AREA TO KEEP PREMISES AS NEAT AS 1. IN THE EVENT OF DISCREPANCIES BETWEEN THE DRAWINGS OR SPECIFICATIONS, IN POSSIBLE DURING CONSTRUCTION. CANOPY: SANDY MATTHEWS 03;22J01 'g THIS PACKAGE, NOTIFY R.H.L. DESIGN GROUP, INC. IMMEDIATELY. 2. PRIOR TO THE FIRST DAY OF OPERATION, THE CONTRACTOR SHALL 3977 LEARY WAY NW pp5C0 -- ®I WIPE DOWN DISPENSERS AND PROVIDE CLEANING SERVICE TO CLEAN REMOVE EXISTING FASCIA ON EXISTING FUEL CANOPY, RAISE sad SEATTLE, WA. 98107 2. R.H.L. DESIGN GROUP, INC. SHALL NOT BE RESPONSIBLE OR HAVE CONTROL OR UP ALL AREAS AFFECTED. DUE TO CONSTRUCTION, INCLUDING BUT CANOPY TO 14'-6" CLEAR HEIGHT, AND REPLACE WITH 206) 706-2203 �RO�ND G CHARGE OVER ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, I ( UpJEAP= SEQUENCES OR PROCEDURES, OR FOR THE SAFETY PRECAUTIONS & PROGRAMS OF NOT LIMITED TO SWEEPING THE DRIVE SLAB AND WASHING OF THE NEW 4'-0" FASCIA WITH LIGHTWELL. (206) 706-2339 FAX 7gi:SUBM1TTED THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING WORK YARD AREA. ON THE PROJECT. 3. SAVE ALL WARRANTY CARDS AND CERTIFICATES. INSTALL NEW "76" SIGN BUGS (2) ON CANOPY AFTER NEW APPROVED BY s/6f E 4. COORDINATE CONSTRUCTION WORK WITH STATION PERSONNEL. FASCIA IS COMPLETE. 3. R.H.L. DESIGN GROUP, INC. HAS NOT BEEN RETAINED FOR REVIEW, SUPER- ARRANGE TO PAY STATION OPERATOR AN EQUITABLE AMOUNT FOR - 0 VISION OR ADMINISTRATION OF THE CONTRACT, NOR THE CERTIFICATION OF PAY- ALL UTILITIES USED DURING CONSTRUCTION. MENTS. CONSTRUCTION COORDINATOR SHALL BE OWNER'S REPRESENTATIVE DURING 5, CONTRACTOR TO FURNISH PORTABLE TOILET WITH CLEANING. INSTALL NEW BLUE ATED COMETS (2) ON CANOPY AFTER CONSTRUCTION & UNTIL FINAL PAYMENT IS MADE. THE OWNER'S REPRESENTATIVE 6. OBTAIN AND PAY ALL REQUIRED ELECTRICAL PERMITS. NEW FASCIA IS PLETE. WILL REVIEW THE PROJECT &RENDER NECESSARY DECISIONS FOR THE PROGRESS OF THE WORK, EXCEPT AS SPECIFIED OTHERWISE IN THE ADDENDA TO SPECIFICATIONS. 7. BELOW GROUND CONDUIT IN TRENCHES SHALL BE GALVANIZED AND WRAPPED, PVC COATED AND RIGID OR AN APPROVED PVC SCHEDULE 1 02/15/011 REVISIONS PER CITY COMMENTS DJW 4. CONTRACTOR IS RESPONSIBLE TO SEE THAT WORK IN FIELD IS DONE IN ACCOR- 40. DANCE WITH ALL CURRENT APPLICABLE NATIONAL, STATE & LOCAL CODES, ORDIN- 8. CONNECT POS EQUIPMENT AS REQUIRED. ESTABLISH LINK WITH ANCES & REQUIREMENTS BY GOVERNING AGENCIES, WHETHER OR NOT SAID CODES, POS SYSTEM THROUGH G-SITE AND COMMUNICATIONS SATELLITE. ORDINANCES, REQUIREMENTS, ETC. ARE SPECIFICALLY SHOWN ON DRAWINGS AND/OR 9. FURNISH QUALIFIED ELECTRICIAN TO CHECK OUT ELECTRONIC INFORMATION: CALLED FOR IN SPECIFICATIONS. EQUIPMENT OPERATION WITH THE GILBARCO REPRESENTATIVE. 5. CONTRACTOR SHALL PROTECT ALL EXISTING ITEMS & FACILITIES TO REMAIN THROUGH- 10. COMPLETE ALL ELECTRICAL INSTALLATIONS FOR NEW SITE AREA: 37,666 SQ. FT. OR 0.8647 ACRE OUT CONSTRUCTION. CONTRACTOR SHALL REPAIR AND/OR REPLACE, AT CONTRACTOR'S MODIFICATIONS AS SHOWN ON PLANS AND SPECIFICATIONS AND AS TYPE OF CONSTRUCTION: II PARKING: TO REMAIN UNCHANGED EXPENSE, ANY EXISTING ITEMS AND FACILITIES TO REMAIN THAT ARE DAMAGED BY PER GILBARCO'S SITE PREP/HARDWARE INSTALLATION MANUAL. THIS USES: ALL STRUCTURES ON THE SITE WILL —4 CONTRACTOR'S OPERATIONS, TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE. INCLUDES INSTALLATION OF A SUB -PANEL FOR THE DISPENSING RETAIN THE SAME USE z� VICINITY MAP EQUIPMENT WITH ONE S'vVTCHED NEUTRAL BREAKER AND ISOLATION 6. GENERAL CONTRACTOR SHALL COORDINATE THE DELIVERY OF ALL TOSCO MARK DATE REVISIONS INITIAL SUPPLIED EQUIPMENT. THE CONTRACTOR IS RESPONSIBLE FOR INSPECTION OF EQUIP- RELAY PER DISPENSER AND SUBMERGED TURBINE PUMP, AND ONE MENT AT TIME OF DELIVERY AND SHALL NOTIFY EQUIPMENT SUPPLIER OF ANY DE_ DEDICATED CIRCUIT OFF THE CONSOLE AND RELATED EQUIPMENT. - 91% �. r - Ip�20OM- FICIENCIES OR DAMAGED EQUIPMENT AND ARRANGE FOR REPLACEMENT. 11. START-UP OF THE AND THE GILBARCO EQUIPMENT WILL BE BY spf_� t 1� lillf4�t OTHERS. 1 �" 1. COVER SHEET 7. PRIOR TO EXCAVATION, DETERMINE AND VERIFY LOCATION OF UTILITY SERVICES IN 12, LOCATION OF ALL ELECTRICAL RISERS TO BE APPROVED BY TMC 528 ih ALL AREAS TO BE EXCAVATED. COMPANY ENGINEER. ALL RISERS WILL BE PVC COATED, RIGID 8. CONTRACTOR SHALL COMPLY WITH ALL PERTNENT LAWS, CODES, REGULATIONS, CONDUIT OR WRAPPED, GALVANIZED, ELECTRICAL CONDUIT EXTENDING GOVERNING AGENCIES & MANUFACTURER SPECIFICATIONS, UNLESS GREATER REQUIRE- A MINIMUM OF 24" BELOW GRADE. S282nd t -- SERVICE STATION NO. 2611068 MENTS ARE INDICATED, OR ARE NECESSARY FOR SAFE WORKING CONDITIONS.Bd I la 4 '1fij 28718 MILITARY ROAD 16282 9. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIF)ING JURISDICTIONS _ "t I'x ayd FEDERAL WAY, WASHINGTON AS REQUIRED FOR INSPECTIONS AND SHALL PAY INSPECTION FEES ASSOCIATED WITH ARCHITECT ABBREVIATIONS op� z= � M -��,2 L��r try s THE WORK. s t+ '' 7_'*"'�� 3 e5284tt P1 TOSCO 10. THE GENERAL CONTRACTOR SHALL APPLY, PAY FOR, AND OBTAIN ELECTRICAL HVAC I �' � MECHANICAL, AND PLUMBING PERMITS. RHL DESIGN GROUP, I N C N- NEW C REFINING AND MARKETING CO. 11. R.H.L. DESIGN GROUP, INC. SHALL APPLY FOR ALL PERMITS WHICH INVOLVE 1550 140th AVE.. N.E., SUITE 100 - E - EXISTING - `S 86i55 " S h PI ` A DMSION OF TOSCO CORPORATION DRAWING SUBMITTAL AND PROCESSING. INCLUDING PLANNING, BUILDING, FIRE, AND S1 (7th St ENVIRONMENTAL HEALTH PERMITS. CONTRACTOR SHALL PICK-UP AND PAY FOR ALL f3ELLEVUE, WASHINGTON ,98005 - f $ N.T.S. -NOT TO SCALE & LICENSEE OF SIP OIL - - c{i PERMIT FEES. CONTRACTOR IS AUTHORIZED A 10% CHARGE FOR PERMIT FEES. (425) 746-4677 V+_? ..-.. th St N.I.C. - NOT IN CONTRACT 12. THE GENERAL CONTRACTOR SHALL PROVIDE THE TOSCO ENGINEER WITH A CON- CONTACT: RICHARD DUGIE U118$[f� STRUCTION SCHEDULE PRIOR TO STARTING THE WORK, SHALL PROVIDE A QUALIFIED CONC. - CONCRETE ARCHITECTURE • ENGINEERING • ENVIRONMENTAL SEE o K JOB SUPERINTENDENT THROUGHOUT THE WORK, AND PROVIDE TOSCO tC13 WITH PHOTOS SHOWING PIPING AND ELECTRICAL TRENCHES PRIOR TO BACKFILL, AND U.G. - UNDERGROUND h4 $y 7550 140th AVENUE N.E., SUITE 100, BELLEWE, WA. 98005 SHALL PROVIDE A SET OF "AS BUILT" MARKUPS AT COMPLETION. r ( G�� INC TEL: (425) 746-4677 FAX: (425) 746 R� OWNER/DEVELOPER O.C. - ON CENTER -iil 13. THE GENERAL CONTRACTOR SHALL PROVIDE BARRICADES AND SAFETY SIGNS PER : (:t) x ,- RHL REVIEW INMAL DATE DATE: 10/1 OSHA REQUIREMENTS. EA. - EACH S2R3 ,St- Q� x�tr 1 PRELIMINARY TOSCO MARKETING C 0 - - PLANNING MDL Ot/17/01 DR. BY: MDI CIO c 14. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERALL CONSTRUCTION SITE CLEAN- , , a ,,, `, LINESS, INCLUDING PROVISION OF A DEBRIS BOX WITH REGULAR SERVICING, REMOVAL °S ' ' (j STEEL BID Z OF ALL CONTRACTOR/SUBCONTRACTOR REFUSE AND DEBRIS, AND SWEEPING OF THE 'S00 N. PRIEST DR. _ ¢_r�1 BLDG PERMIT MDL 03/19/07 APPR.. RTC c ENTIRE YARD AREA AT THE COMPLETION OF THE WORK. PHOENIX, AZ. 85072 v �+� I C `1 r - GENERAL BID 15. ALL PROCEDURES, TESTING, MATERIALS, LABOR &EQUIPMENT SHOWN ON THE PLANS CONTACT: JOHN PATTON - 4 nterbu 0 I � 1 " �3 h StPERMIT REVS SHALL BE FURNISHED & INSTALLED BY THE GENERAL CONTRACTOR. UNLESS NOTED 5 1A,, Y F 6 k-DL. L WAY CONSTRUCTION SHEET C OTHERWISE IN THESE PLANS. EQUIPMENT OR MATERIALS NOTED ONLY AS "FURNISHED +�i A + AL NI0 DEPTt Do not use drawing r O a BY TOSCO" SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. f ~ for construction A_ N ` unless initialed 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 o C 7 - a 7 sa 0 ,n 7 9 3 d 5 0% 7 8 9 1A Iv 1/ 18 KEY NOTES 1.1 REMOVE EXISTING FASCIA ON CANOPY 1.2 INSTALL NEW CANOPY FASCIA, SEE STRUCTURAL DRAWINGS 1.3 INSTALL NEW "76" BUG SIGN ON CANOPY (TYP. OF 2) 1.4 INSTALL NEW 76 BLUE GRADATED COMET GRAPHICS (TYP. 2 PLACES) I 1.5 INSTALL NEW PLANTER CURB A 1.6 RELOCATE PARKING STALLS 0C c f GENERAL NOTES LOT AREA: 37,666 SQ. FT. EXISTING GAS STATION AREA: 2,300 SQ. FT. EXISTING CANOPY AREA: 1.100 SQ. FT. PROPOSED CANOPY AREA: 1,150 SQ. FT. ZONE: BN TYPE OF CONSTRUCTION: II 1 EXISTING PARKING: 10 STALLS .>,xalm� F 20 10 0 20 40 60 E 1 "=20'-0" 1 02/15/01 REVISIONS PER CITY COMMENTS DJW C MAX-KI DATE I REVISIONS INITIAL SITE PLAN SERVICE STATION NO. 2611068 C 28718 MILITARY ROAD FEDERAL WAY, WASHINGTON TOSC( - - REFINING AND MARKETING CO. A DIVISION OF TOSCO CORPORA-1-ION T O S C® & LICENSEE OF BP OIL E ARCHITECTURE - ENGINEERING • ENVIRONMENTAL SERVICES 1550 140tb AVENUE N.E., SUITE 100, BELLEVUE, WA. 98005-4516 (3AODP dNC TEL: (425) 746-4677 FAX: (425) 746-6836 RHL REVIEW INMAL DATE DATE: 10/11/00 PRELIMINARY PLANNING MDL 61117/0, DR. BY: MDL s STEEL BID BLDG PERMIT MDL 03/19/01 APPR.: RTD GENERAL BID m95 PERMIT REVS RHL # 3978,10 �r 4 CONSTRUCTION SHEET '' d3Afy i'i'-,� s;.§�,�.-,r Do not use drawing A-1 BUi�-DlNG" r PT for construction unless initialed Ar FE r L i 7 A A c -f !s - c•� ... IV L mmi J 109i mWr:C F E 00 B 3 i 0 J1 ( EXISTING NORTH CANOPY ELEVATION 11 /4" = 1'-O" 47'-0" -------------------- 24'-5" J.J. ISERS (E) CANOPY COLUMN IG IV IMF la 10 I/ its KEY NOTES 1.1 EXISTING CANOPY FASCIA TO BE REMOVED. 1.2 INSTALL NEW 36" DIA. INTERNALLY ILLUMINATED 76 LOGO SIGNS. TYPICAL 2 PLACES, SEE SHEET C06273. 1.3 INSTALL NEW LSI "SQUIRE" CANOPY LIGHTWELL FIXTURES. SEE SHEET CS-1. 1.4 INSTALL NEW 76 ORANGE VINYL ACCENT AT BASE OF FASCIA. 1.5 INSTALL NEW 76 CANOPY FASCIA PER DETAILS ON SHEET CS-1. 1.6 INSTALL NEW 76 BLUE GRADATED COMET GRAPHICS (TYP. 2 PLACES). = l L IF E1 EXISTING EAST CANOPY ELEVATION Eg EXISTING WEST CANOPY ELEVATION 47'-0" C — — —•_ �� — — � MARK SATE FiEVISI0N3 INITIAL EXISTING CANOPY ELEVATIONS AND DETAILS SERVICE STATION NO. 2611068 28718 MILITARY ROAD FEDERAL WAY, WASHINGTON TOSCO REFINING AND MARKETING CO. O f A D & LICENSEE TIOOSCO CORPORATION T O SC O e OF BP OIL ARCHITECTURE • ENGINEERING • ENVIRONMENTAL SERVICES 1550 140th AVENUE N.E., SUITE 100, BELLEVUE, WA. 98005-4516 SUP U1C TEL: (425) 746-4677 FAX: (425) 746-6836 F*11- FIEVIEVV INITIAL C>ATE DATE: 10/11/00 PRELIMINARY -- PLANNING mp 0( l D DR. BY: MDL STEEL BID BLDG PERMIT APPR.: RTD A GENERAL BID Al EXISTING SOUTH CANOPY ELEVATION PERMIT REVS CONSTRUCTION SHEET ` a -' Do not use drawing for cnstructi/� oon -/ unless initialed AEG 9 3 A S fS 7 8 9 in11 •Io �� . a� — r L i 3 Ct. C=� 7 E? E7 10 12 13 14 15 16 KEY NOTES 17 L K J1 1/4" = 1'-0" F E N E1 E 1/4" = 1'-0" Ni M N O U V) H J 40 N a U N E 0 E c .5 0 Q. M M A z Al Q 1/4" L t] 1 NEW NORTH CANOPY ELEVATION WITH SIGN A NEW EAST CANOPY ELEVATION NEW SOUTH CANOPY ELEVATION WITH SIGN B ro A FORMS E8 1/4" = 1'-0" An NEW WEST CANOPY ELEVATION 9 10 24'-5" 12 13 FORMS YP. 1.1 EXISTING CANOPY FASCIA TO BE REMOVED. 1.2 INSTALL NEW 36" DIA. INTERNALLY ILLUMINATED 76 LOGO SIGNS. TYPICAL 2 PLACES. SEE SHEET C06273. 1.3 INSTALL NEW LSI "SQUIRE" CANOPY LIGHTWELL FIXTURES. SEE SHEET CS-1. 1.4 INSTALL NEW 76 ORANGE VINYL ACCENT AT BASE OF FASCIA. 1.5 INSTALL NEW 76 CANOPY FASCIA PER DETAILS ON SHEETS CS-1. 1.6 INSTALL NEW 76 BLUE GRADATED COMET GRAPHICS (TYP. 2 PLACES). COLOR KEY Ol SHERWIN WILLIAMS "TOSCO LIGHT GRAY" O2 SHERWIN WILLIAMS "TOSCO DARK GRAY" O3 SHERWIN WILLIAMS "TOSCO BRILLIANT WHITE" O4 SHERWIN WILLIAMS "76 ORANGE" O5 SHERWIN WILLIAMS "76 REFLEX BLUE" O6 SHERWIN WILLIAMS "BLACK" NOTE: SEE COLOR PALETTE FOR ACTUAL PAINT COLORS. AREA CALCULATIONS NORTH ELEVATION CALCULATIONS: SIGN AREA: 7.07 SF BUIDLING FACE AREA: 215.44 SF SOUTH ELEVATION CALCULATIONS: SIGN AREA: 7.07 SF BUIDLING FACE AREA: '215.44 SF t U4/12/01 GRAPHIC REVISIONS PER CITY COMMENTS MOIL k4AWj DATE I REVISIONS INt11AL NEW CANOPY ELEVATIONS AND DETAILS SERVICE STATION NO. 2611068 28718 MILITARY ROAD FEDERAL WAY, WASHINGTON TOSCO REFINING AND MARKETING CO. grip A DIVISION OF TOSCO CORPORATK)N & LICENSEE OF BP OIL "IrOSCO ARCHffEMJRE • ENGINEERING • ENVERONMENTAL SERVICES 1550 140th AVENUE N.E.. SUITE 100. BELLEVUE, WA. 98005-4516 GROUP 'We TEL: (425) 746-4677 FAX: (425) 746-6836 RHL REVIEW INFt1AL DATE DATE: 10/11/00 PRELIMINARY PLANNING MDL Oi/17/01 DR. BY: MDL STEEL BID BLDG PERMIT MDL 03119/O1 APPR.: RTD GENERAL BID e # 3 PERMIT REVS CONSTRUCTION SHEET Do not use drawing APR ' for construction 2"1 unless initialed 14 15 16 17 18 7 ..12 1 13 1 14 1 is is 17 NOR] M-1 j I MEIN "qr ; mmmutz C 6 A "1-44 5HRU55: Ar orvitine "D, A*, 1115 I2 &ROUNDCOVER sod F&I 511 FIP1 S8-,->I'C,4"E 2-,q-031 MF4& 240.',)0' R". all MAPLE CHAIN E CWAPA7 RAIL E❑I APZOR',/ITAE (TYP) F —,I D, FE] PROOPMTy LI�e W55TANTIAL SHRIM PLANTIN&S ( D REMOVE ALL EXISTIN& 5HRUM fi N"IN 7HESE BEM. (-14 JUNIPER, -6 HOLLYS) x 1,100 ----- --------- --- la EXIST1116 SOD MILITARY ROAD SOUTH Thujo ocrldentolls 'Emerald Cireen' N/A IMPORT PLANT MATERIAL LEGEND KEY SIZE COMMON NAME E30TANICAL NAME 11REES U. Red 5unset Maple Aaer rubra 1.51 CAL. @ 145 ABOOTBALL 5HP ,U135 Otto Luykem Laurel Frunus laurocarasus 'Otto Luyken' 24" MIN. HT. Holly Ilex cranoto 'Convexo' 24" MIN. HT. (SROUNDCOVER - KinnIkInniak Aratostophylus Uvo-Urso 151, O.C. �ml 1111111111111111M mll� M.114 F*-N- FMVU=-W INMAL DATE. 10/1 /00 PRELIMINARY DR. BY, MDL PLANNING STEEL BID APPR.: RTD BLDG PERMIT GENERAL BID RHL # 3978.10 PERMIT REYS SHEET or 36N�UCTION Do not use drawing Ll eui-"DINC, iEPT- for construction unless initialed T I 1 4 1 le 17 is 10 In 12 13 14 is 03 i PM N i #10 TEKS (TYPICAL) CONT. L2x2x16Ga: ACM FASCIA I o � 18 GA. BRACKET 4 @ 48" O.C. 00 DECAL t�l +14'-0" P.F. ORANGE SOFFIT / GUTTER GUTTERSEAL SEALANT 20 GA. GALV. FLASHING :d — L3x3x18Ga. FRAME ® 48"o.c. Rm 1/4" STIFFENERS SPOT wri r)N NS & FS TYP OR (3) PURLIN #10 SMS 311 0I LEADER w/ COVER 4'-0" NOTE! LSI SQUIRE LIGHT FIXTURES OR APPROVED EQUAL BY ELECTRICAL SUBCONTRACTOR. 20GA ASTM A653 SQ GR. 40 DECK W/3" RIBS ® 16" O/C PREFINISHED WHITE FASTEN RIBS W/#14 SMS ENDS, PURLINS & MIDSPANS NEW TS12x12x1/4 TO MATCH EXIST. COL (VERIFY) i SECTION SCALE: 1" = 1'—O" „ 6" 6,, „„ 'I II x w X N X N h 3' SQUARE (EXIST.) 1 /4" STIFFENERS NS & FS TYP —N PL 3/4x13 1/2"x1'-8" 16 4) 5/8"DIA A307'S `—(4) 5/8"OA307's PURLIN �L2 1 /2x2x3/16 3 16 2-6 �.,�P x4'-0" LLH 3 16 2-6 --------- — MFRS. DECK CLIP OR 1/4" DIA. STAINLESS STEEL BOLT EA. DECK 20CA COLLAR RIB, ALT. SIDES OF BEAM EXCEPT HEAVY MASTIC FASTEN TO BOTH SIDES OF BEAM 2"PC.4"DIA. SCH.40 PIPE AT LAST RIB 45' TOP OF ISLAND #10 TEKS (TYPICAL) CONT. L2x2x16Ga: d ACM FASCIA i o n 18 GA. BRACKET d. @ 48" O.C. NOTE: WELDING SHALL BE INSPECTED BY AN APPROVED TESTING AGENCY IN ACCORDANCE WITH THE 1997 UBC, SECTION 1701.5.1, TOP OF PAVEMENT 4#6's VERT. W/#3 TIES @12" FOOTING DECAL- 00 +14'-0" P.F. ORANGE SOFFIT / GUTTER SECTION SCALE: 1 " = 1'-0" PURLIN DECK D ETAI L SCALE: 1" = 1'-0" 20 GA. GALV. FLASHING d — L3x3x18Ga. FRAME @ 48"o.c. SPOT WEL OR (3) #10 SMS 20GA ASTM A653 SQ GRADE L2.1/2x2x3/16 (LLV) 40 DECK W/3" RIBS @ 16" O/C FASTEN RIBS W/#14 SMS PREFINISHED WHITE ® 48" O.C. FASTEN RIBS W/#14 SMS @ ENDS, PURLINS & MIDSPANS 2 "x 16GA FLAT STRAP FLG STAY — (2)#14 SMS ® DECK RIBS & PURLIN [vri"Ap2 2 �4 t BUILDIN9 DEFT. • 00 61 0 c �F PEYTON TOwpTA AND ASSOCIATES 954 Town & Country Rd Orange, CA 92668 Ph:(714) 245-4930 Fox:(714) 245-4933 0 0Lu 0 two z z p \ Z O U 6 Q N Z 1c J � Q O w Z 0 a U ad J O Z O O Q N 1— w `c a wX J Q J N U oo Of d' � >- � 00 w o N F- N w tL- HE NAME C �+rr�� S2 JOB NO. 3978.10 DRAWING N0, CS-2 DRAWING REVISION NO.2 8 - 8 3/8 - 8 10 1/8 5 a --- r `0 ' I6 si GROUNDI WIRE l � 1 l 36 11 /32 36 1 /8 I0 I 101 L 1 2 3 4 row , 1 00-00-002-0124 803827 MS 1/4-20 X 1 HX 2A SS PLN 3 2 00-00-002-0120 A01751 WSHR FLAT TYP-8 1/4 REG SS REG PLN 2 3 00-40-920-0220 A01772 WSHR LOCK SPRING 1/4 STD SS REG PLN 2 4 00-40-640-0740 A01773 NUT HX STD 1/4-20 304 SS PLN 5 5 00-00-007-6967 ----- RING TERMINAL #10 STUD 16-14 AWG 1 6 00-00-005-2329 818069 BACK .080 ALUM SHT 1 SPECIFICATIONS 1. AREA IN SQ FT: 7 SQ FT 2. LUMENS: 8040 3. LUMENS PER SQ FT: 1149 4. VOLTAGE: 110 VAC 5. TOTAL CONN. LOAD: 1.9A 6. CIRCUITS: 1-20 AMP 7. SIGN IS TO BE WIRED WITH 14 GAGE AWM 105C PER DIAGRAM ON BALLAST. ELECTRICAL LEADS TO BE 12 GAGE MTW WIRE. SIGN MUST BE GROUNDED WITH 14 GAGE GREEN WIRE. 8. MATERIAL SPECIFICATIONS: ALUMINUM SHAPES 6063-175 ALUMINUM SHEETS 3003-1-114 STEEL SHAPES ASTM A36 STEEL SHEET ASTM A591 STEEL TUBE ASTM A500B 9. MAXIMUM DESIGN WIND LOAD: 30 PSF 10. EST. WEIGHT OF CRATED SIGN: 72 LBS EST. WEIGHT OF UNCRATED SIGN: 50 LBS 11. CRATED VOLUME OF SIGN: 17.9 CU FT 12. OVERALL DIMENSIONS OF SIGN: HEIGHT: 36 IN. WIDTH: 36 IN. DEPTH WITH FACE: 10 IN. DEPTH WITHOUT FACE: 5 IN. 13. TOTAL LENGTH OF WELD REQUIRED 18 IN. 14. TOTAL LENGTH OF WIRE REQUIRED 648 IN. RC � p r,,.