Loading...
16-105827 (2)DRIVING DIRECTIONS 11 (FROM SEATTLE TACOMA INTERNATIONAL AIRPORT - SEATAC, WA): HEAD SOUTHEAST ON AIRPORT EXPRESSWAY TOWARD DEPARTURES DR. USE THE LEFT LANE TO KEEP LEFT. KEEP LEFT. SLIGHT LEFT ONTO AIRPORT EXPRESSWAY. KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR WASHINGTON 518 E/INTERSTATE 5/INTERSTATE 405 AND MERGE ONTO WA-518 E. MERGE ONTO WA-518 E. TAKE THE EXIT ONTO 1-5 S. TAKE EXIT 142B FOR WA-18 W TOWARD S 348TH ST. USE THE RIGHT LANE TO TURN RIGHT ONTO WA-18 W. TURN RIGHT ONTO 16TH AVE S. TURN RIGHT ONTO S 344TH ST. DESTINATION WILL BE ON THE RIGHT. JURISDICTION: ZONING CLASS: OCCUPANCY GROUP: PROPOSED USE TAX PARCEL ID: PROPOSED LEASE AREA: NODE 1 (NAD83): NODE 2 (NAD83): NODE 3 (NAD83): GROUND ELEVATION (NAVD88) STRUCTURE HEIGHT ,�CI�E WALMART SMALL LL - BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 PROJECT INFORMATION 1 CITY OF FEDERAL WAY CE (COMMERCIAL ENTERPRISE) M (RETAIL) TELECOM 2121049010 22.14 ACRES LATITUDE: 470 17' 34.9" LONGITUDE: 122' 18' 40.8" LATITUDE: 47' 17' 34.9" LONGITUDE: 122' 18' 40.7" LATITUDE: 47' 17' 31.6" LONGITUDE: 122' 18' 40.8" 330.6' ± 25'-2" ± (NODE 1) 23'-8" ± (NODE 2) 33'-0" ± (NODE 3) 35'-4" ± (TOP OF BUILDING PARAPET) CODE COMPLIANCE � ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT CONDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: WASHINGTON STATE AND LOCAL BUILDING CODES WITH THE FOLLOWING REFERENCE CODE: 2012 IBC, STANDARDS AND AMENDMENTS WAC 51-50 2012 IMC, STANDARDS AND AMENDMENTS WAC 51-52 2012 IFC, STANDARDS AND AMENDMENTS WAC 51-54 2012 WASHINGTON STATE ENERGY CODE WAC51-11C 2012 UPC, STANDARDS AND AMENDMENTS WAC 51-56 2014 WASHINGTON CITIES ELECTRICAL CODE WALMART OWNER CONTACT: DAVID HESS WALMART WIRELESS FIELD OPERATIONS PHONE: (479) 204-7148 david.w.hess@wal-mart.com WALMART STORE CONTACT: JEFFERY FITTINGER STORE MANAGER PHONE: (360) 386-4608 CONTACTS APPLICANT/CLIENT CONTACT: SOPHIA MEKKERS BLACK ROCK PHONE: (503) 380-1564 sophia@blk-rock.com APPLICANT: VERIZON WIRELESS MICHAEL CUNNINGHAM michael.cunningham2@verizonwireless.com A&E CONTACT: RICK MATTESON ACOM CONSULTING, INC 1125 SE CLATSOP ST PORTLAND, OR 97202 PHONE : (425) 209-6723 rick.matteson@acomconsultinginc.com VERIZON WIRELESS PROPOSES TO INSTALL NEW EXTERIOR V"JALL MOUNTED SMALL CELL PANEL ANTENNAS AND GPS UNIT WITH COAX ROUTING FROM THE VZW EQUIPMENT O THE ANTENNAS VIA SLEEPERS ON ROOF. ALL PROPOSED RF EQUIPMENT WILL BE INSTALLED IN THE (2) PR("POSED EQUIPMENT CABINETS LIST OF DRAWINGS 11 SHEET DESCRIPTION T-1 COVER SHEET T-2 GENERAL NOTES AND SYMBOLS A-1 PROPOSED SITE PLAN - A-2 PROPOSED ROOF & EQUIPMENT PLANS r`. _ low A-3 ENLARGED PLANS & ELEVATIONS A-4 ENLARGED PLANS &ELEVATIONS A-5 ELEVATIONS SITE PLAN, oV %. palidt Number, RF-1 PROPOSED ANTENNA CONFIGURATION App I foved'81y. Date: E-0 GENERAL ELECTRICAL NOTES CommemS;�SSs`, SSud.z� E-1 ELECTRICAL BUILDING PLAN E-2 GROUNDING DETAILS APPROVALS TITLE SIGNATURE DATE REPRESENTATIVE RE ENGINEER SITE OWNER DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. wi 0 • • y t, 496 lrk i \ I . y No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Client: verizonv Implementation Team: A& ­ET eam: CONSULTING I Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: 1 Project Number: Date: 09/131 Drafter: Designer: RM RM�..< Project Manager: &f4sW0I609e6ofdNAT AM R J CDS Revision No: Sheet No: 1 T-1 GENERAL NOTES 1. WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. ALL 16. VERIFY ALL EXISTING DIMENSIONS PRIOR TO PERFORMING WORK. NECESSARY LICENSES, CERTIFICATES, ETC., REQUIRED BY AUTHORITY HAVING JURISDICTION SHALL BE PROCURED AND PAID FOR BY THE CONTRACTOR. 17. VERIFY LOCATION OF ALL BURIED UTILITIES PRIOR TO ANY EXCAVATION. 2. ACOM HAS NOT CONDUCTED, NOR DOES IT INTEND TO CONDUCT ANY INVESTIGATION AS TO THE PRESENCE OF HAZARDOUS MATERIAL, INCLUDING, BUT NOT LIMITED TO, ASBESTOS WITHIN THE CONFINES OF THIS PROJECT. ACOM DOES NOT ACCEPT RESPONSIBILITY FOR THE INDEMNIFICATION, THE REMOVAL, OR ANY EFFECTS FROM THE PRESENCE OF THESE MATERIALS. IF EVIDENCE OF HAZARDOUS MATERIALS IS FOUND, WORK IS TO BE SUSPENDED AND THE OWNER NOTIFIED. THE CONTRACTOR IS NOT TO PROCEED WITH FURTHER WORK UNTIL INSTRUCTED BY THE OWNER IN WRITING. 3. ALL MATERIAL FURNISHED UNDER THIS CONTRACT SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE CONTRACTOR SHALL REPAIR OR REPLACE AT HIS EXPENSE ALL WORK THAT MAY DEVELOP DEFECTS IN MATERIALS OR WORKMANSHIP WITHIN SAID PERIOD OF TIME OR FOR ONE YEAR AFTER THE FINAL ACCEPTANCE OF THE ENTIRE PROJECT, WHICHEVER IS GREATER. 4. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND UTILITIES AT THE JOB SITE BEFORE WORK IS STARTED. NO CLAIMS FOR EXTRA COMPENSATION FOR WORK WHICH COULD HAVE BEEN FORESEEN BY AN INSPECTION, WHETHER SHOWN ON THE CONTRACT DOCUMENTS OR NOT, WILL BE ACCEPTED OR PAID. 5. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING DIMENSIONS AND CONDITIONS AT THE JOB SITE WHICH COULD AFFECT THE WORK UNDER THIS CONTRACT. ALL MANUFACTURERS RECOMMENDED SPECIFICATIONS, EXCEPT THOSE SPECIFICATIONS HEREIN, WHERE MOST STRINGENT SHALL BE COMPLIED WITH. 6. THE CONTRACTOR SHALL VERIFY AND COORDINATE SIZE AND LOCATION OF ALL OPENINGS FOR STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL, OR ARCHITECTURAL WORK. 7. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF ANY AND ALL MECHANICAL, ELECTRICAL, PLUMBING, OR STRUCTURAL ELEMENTS, AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE ARE MET. NOTIFY THE CONSULTANT OF ANY CONFLICTS. THE CONSULTANT HAS THE RIGHT TO MAKE MINOR MODIFICATIONS IN THE DESIGN OF THE CONTRACT WITHOUT THE CONTRACTOR GETTING ADDITIONAL COMPENSATION. 8. DO NOT SCALE THE DRAWINGS. DIMENSIONS ARE EITHER TO THE FACE OF FINISHED ELEMENTS OR TO THE CENTER LINE OF ELEMENTS, UNLESS NOTED OTHERWISE. CRITICAL DIMENSIONS SHALL BE VERIFIED AND NOTIFY THE CONSULTANT OF ANY DISCREPANCIES. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEAN UP OF ALL TRADES AND REMOVE ALL DEBRIS FROM THE CONSTRUCTION SITE. AT THE COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL THOROUGHLY CLEAN THE BUILDING, SITE, AND ANY OTHER SURROUNDING AREAS TO A BETTER THAN EXISTING CONDITION. 10. THE CONTRACTOR IS RESPONSIBLE FOR ADEQUATELY BRACING AND PROTECTING ALL WORK DURING CONSTRUCTION AGAINST DAMAGE, BREAKAGE, COLLAPSE, ETC. ACCORDING TO APPLICABLE CODES, STANDARDS, AND GOOD CONSTRUCTION PRACTICES. 11. THE CONTRACTOR SHALL MEET ALL OSHA REQUIREMENTS FOR ALL INSTALLATIONS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EXISTING CONSTRUCTION AND REPAIR ALL DAMAGES TO BETTER THAN NEW CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DAMAGE TO THE BUILDING SITE OR ANY ADJACENT STRUCTURES AROUND THE PROJECT. THE CONSULTANT SHALL BE SOLE AND FINAL JUDGE AS TO THE QUALITY OF THE REPAIRED CONSTRUCTION. ANY ADDITIONAL MODIFICATIONS WHICH MUST BE MADE SHALL BE MADE AT THE CONTRACTOR'S EXPENSE. 13. WHERE ONE DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS OR REFERRED TO IN THE SPECIFICATIONS, UNLESS NOTED OTHERWISE. 14. WHERE NEW PAVING, CONCRETE SIDEWALKS OR PATHS MEET EXISTING CONSTRUCTION, THE CONTRACTOR SHALL MATCH THE EXISTING PITCH, GRADE, AND ELEVATION SO THE ENTIRE STRUCTURE SHALL HAVE A SMOOTH TRANSITION. 15. THE CONTRACTOR SHALL MODIFY THE EXISTING FLOORS, WALL, CEILING, OR OTHER CONSTRUCTION AS REQUIRED TO GAIN ACCESS TO AREAS FOR ALL MECHANICAL, PLUMBING, ELECTRICAL, OR STRUCTURAL MODIFICATIONS. WHERE THE EXISTING CONSTRUCTION DOORS, PARTITIONS, CEILING, ETC., ARE TO BE REMOVED, MODIFIED, OR REARRANGED OR WHERE THE EXPOSED OR HIDDEN MECHANICAL, ELECTRICAL, SYSTEMS ARE ADDED OR MODIFIED, THE GENERAL CONTRACTOR SHALL REPAIR, PATCH AND MATCH ALL EXISTING CONSTRUCTION AND FINISHES OF ALL FLOORS WALLS AND CEILINGS. WHERE CONCRETE MASONRY CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL TOOTH IN ALL NEW CONSTRUCTION TO MATCH THE EXISTING BOND. WHERE CONCRETE CONSTRUCTION IS MODIFIED, THE CONTRACTOR SHALL VERIFY THE EXACT DETAILS TO BE USED FOR CONSTRUCTION. ALL WORK SHALL BE COVERED UNDER THE GENERAL CONTRACT. 18. IN RAWLAND CONDITIONS, TOWER FOUNDATION STRUCTURAL STEEL TO BE GROUNDED PRIOR TO CONCRETE POUR. TOWER FOUNDATION STRUCTURAL STEEL TO BE CONNECTED TO PERMANENT GROUND ROD PRIOR TO TOWER ERECTION. TOWER GROUND MUST BE MAINTAINED AT ALL TIMES. 19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FOR COMMERCIAL POWER IMMEDIATELY UPON AWARD OF CONTRACT. THE GENERAL CONTRACTOR IS REQUIRED TO KEEP ALL DOCUMENTATION RECEIVED FROM THE POWER COMPANY, ACKNOWLEDGING APPLICATION FOR POWER, WRITTEN AND VERBAL DISCUSSIONS WITH THE POWER COMPANY, ETC. 20. THE GENERAL CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION OF THE EXPECTED DATE OF COMPLETION OF THE POWER CONNECTION FROM THE POWER COMPANY. 21. IF THE POWER COMPANY IS UNABLE TO PROVIDE THE POWER CONNECTION BY OWNER'S REQUIRED DATE, THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN A TEMPORARY GENERATOR UNTIL THE POWER COMPANY CONNECTION IS COMPLETED. COSTS ASSOCIATED WITH THE TEMPORARY GENERATOR TO BE APPROVED BY THE OWNER. 22. IF THE GENERAL CONTRACTOR FAILS TO TAKE NECESSARY MEASURES AS DESCRIBED IN NOTES 19, 20 AND 21 ABOVE, THE GENERAL CONTRACTOR SHALL PROVIDE A TEMPORARY GENERATOR AT NO COST TO THE OWNER. 23. PLANS PART OF THIS SET ARE COMPLEMENTARY. INFORMATION IS NOT LIMITED TO ONE PLAN. DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT, WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSION TO THIS PROJECT EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. THESE PLANS WERE PREPARED TO BE SUBMITTED TO GOVERNMENTAL BUILDING AUTHORITIES FOR REVIEW FOR COMPLIANCE WITH APPLICABLE CODES AND IT IS THE SOLE RESPONSIBILITY OF THE OWNER AND/OR CONTRACTOR TO BUILD ACCORDING TO APPLICABLE BUILDING CODES. 24. IF CONTRACTOR OR SUB -CONTRACTOR FIND IT NECESSARY TO DEVIATE FROM ORIGINAL APPROVED PLANS, THEN IT IS THE CONTRACTOR'S AND THE SUB -CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE ARCHITECT WITH 4 COPIES OF THE PROPOSED CHANGES FOR HIS APPROVAL BEFORE PROCEEDING WITH THE WORK. IN ADDITION THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY APPROVALS FROM THE BUILDING AUTHORITIES FOR THE PROPOSED CHANGES BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR AND SUB -CONTRACTORS SHALL BE RESPONSIBLE FOR PROCURING ALL NECESSARY INSPECTIONS AND APPROVALS FROM BUILDING AUTHORITIES DURING THE EXECUTION OF THE WORK. 25. IN EVERY EVENT, THESE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS SHALL BE INTERPRETED TO BE A MINIMUM ACCEPTABLE MEANS OF CONSTRUCTION BUT THIS SHALL NOT RELIEVE THE CONTRACTOR, SUB -CONTRACTOR, AND/OR SUPPLIER/MANUFACTURER FROM PROVIDING A COMPLETE AND CORRECT JOB WHEN ADDITIONAL ITEMS ARE REQUIRED TO THE MINIMUM SPECIFICATION. IF ANY ITEMS NEED TO EXCEED THESE MINIMUM SPECIFICATIONS TO PROVIDE A COMPLETE, ADEQUATE AND SAFE WORKING CONDITION, THEN IT SHALL BE THE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE DRAWINGS. FOR EXAMPLE, IF AN ITEM AND/OR PIECE OF EQUIPMENT REQUIRES A LARGER WIRE SIZE (I.E. ELECTRICAL WIRE), STRONGER OR LARGER PIPING, INCREASED QUANTITY (I.E. STRUCTURAL ELEMENTS), REDUCED SPACING, AND/OR INCREASED LENGTH (I.E. BOLT LENGTHS, BAR LENGTHS) THEN IT SHALL BE DEEMED AND UNDERSTOOD TO BE INCLUDED IN THE BID/PROPOSAL. THESE DOCUMENTS ARE MEANT AS A GUIDE AND ALL ITEMS REASONABLY INFERRED SHALL BE DEEMED TO BE INCLUDED. 26. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS SHALL NOT BE CONSTRUED TO CREATE A CONTRACTUAL RELATIONSHIP OF ANY KIND BETWEEN THE ARCHITECT AND THE CONTRACTOR. BUILDING/WALL/DETAIL SECTION Detail Number A A-1 Sheet Number Where Detailed LINE/ANTENNA NOTES 1. ALL THREADED STRUCTURAL FASTENERS FOR ANTENNA SUPPORT ASSEMBLES SHALL CONFORM TO ASTM A307 OR ASTM A36. ALL STRUCTURAL FASTENERS FOR STRUCTURAL STEEL FRAMING SHALL CONFORM TO ASTM A325. FASTENERS SHALL BE 5/8" MIN. DIA. BEARING TYPE CONNECTIONS WITH THREADS EXCLUDED FROM THE PLANE. ALL EXPOSED FASTENERS, NUTS, AND WASHERS SHALL BE GALVANIZED OTHERWISE NOTED. CONCRETE EXPANSION ANCHORS SHALL BE HILTI KWIK BOLTS UNLESS OTHERWISE NOTED. -ALL ANCHORS INTO CONCRETE SHALL BE STAINLESS STEEL. 2. NORTH ARROW SHOWN ON PLANS REFERS TO TRUE NORTH. CONTRACTOR SHALL VERIFY MAGNETIC NORTH AND NOTIFY CONSULTANT OF ANY DISCREPANCY BEFORE STARTING CONSTRUCTION. 3. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE STAINLESS STEEL HARDWARE THROUGHOUT. 4. THOROUGHLY REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS. 5. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. ALL BENDS TO BE A MIN. OF 8" RADIUS. 6. FOR GROUNDING TO BUILDING FRAME AND HATCH PLATE GROUND BARS. USE A TWO -BOLT HOLE NEMA DRILLED CONNECTOR SUCH AS T&B 32007 OR APPROVED EQUAL. 7. FOR ALL EXTERNAL GROUND CONNECTIONS, CLAMPS AND CADWELDS, APPLY A LIBERAL PROTECTIVE COATING OR AN ANTI -OXIDE COMPOUND SUCH AS "NO -OXIDE A" BY DEARBORN CHEMICAL COMPANY. 8. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY THERMO-WELDING. USE ERICO T-319 GALVANIZING BAR/COLD GALVANIZING PAINT. 9. SEAL ALL CONDUIT PENETRATIONS INTO MODULAR BUILDING WITH A SILICONE SEALANT AND ALL CONDUIT OPENINGS. 10. ANTENNAS AND COAX TO BE PROVIDED BY VERIZON WIRELESS, CONTRACTOR TO COORDINATE DELIVERY. PROJECT INFORMATION 1. THIS IS AN MANNED FACILITY WITH RESTRICTED ACCESS EQUIPMENT AND WILL BE USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE. 2. VERIZON WIRELESS CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE SERVICED ONLY BY VERIZON WIRELESS EMPLOYEE SERVICE PERSONNEL FOR REPAIR PURPOSES ONLY. THIS FACILITY IS OCCUPIED AND IS DESIGNED FOR HUMAN OCCUPANCY. SITE PLAN APPROVAL Pernut Number: - GS B'a- Approved By: Date: „2 - C bts:i.�..R. to -Eo . -C'.'twQ. �}p .E- i SGto�t CQ LEGEND I IMPORTANT NOTICE REFERENCE C A-1 Referenced Drawing LARGE SCALE DETAIL ■ Detail Number B A-1 Sheet Number Where Detailed THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY OTHERS. ACOM CONSULTING CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB -CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION, No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Client: V U r i z 0 n,, Implementation Team: ■R. Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 T-2 AREA 22"x34" SCALE: 1" = 20'-0" 11"x17" SCALE: 1" = 40'-0" 20' 10, 0" 20' EXISTING WALMART PARKING AREA S344THST 'x SI) ; Yi-, ,I I k. r'iiV VAL Permit Number: lb " _ Approved `By: Date: CO-, - c — 1 ` cats: <7,��-� ya" 11�n 11r lire i -- %-,t> Gc G2 . EXISTING OPEN FIELD PROPOSED SITE PLAN i DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Client: Implementation Team: s K I A&E Team: Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: SITE PLAN Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 A-1 I I I I I I I I gNM MIN i.- - NODE 3 I I22"x34" SCALE: 1132" = 1'-0" 11"x17" SCALE: 1/64" = 1'-0" Ed. VERIZON WIRELESS WALL MOUNTED ANTENNA MOUNT L�J I -- I J 28'-8" ± r-- I, u .0f __. VERIZON WIRELESS WALL MOUNTED CONDUITS: • (2) 2" EMT FOR FIBER & POWER TO ANTENNAS ii 11 El 3 4'-0" x 4'-0" - A-3 CONCRETE PAD 2'-0" PAINT THE EQUIPMENT CABINETS, CONDUIT AND ALL HARDWARE TO MATCH EXISTING BUILDING COLOR LOAD CENTER (ON CABINET) VERIZON WIRELESS WALL MOUNTED CONDUITS: a 1 • (3) 2" EMT FOR FIBER CABLE • o ' z I. o • X A-3 TO ANTENNAS o _ _—___ ==J EDGE OF ROOF I VERIZON WIRELESS EQUIPMENT CABINET I i (PAD MOUNTED) II L------------------- j " 22"x34" SCALE: 1/4" = 1'-0" 11"x17" SCALE: 1/8" = T-0" L l ILA.......... ....... ...... — -- -- v 1 I © E E © E _ ..... Ell -- L `VERIZON WIRELESS WALL MOUNTED ANTENNA MOUNT Immense 0 1 0 ENLARGED EQUIPMENT PLAN 2 4' 3' 2 1 0 4' NOTE: CONTRACTOR SHALL NOT DISTURB OR DAMAGE THE EXISTING ROOFING SYSTEM IN ANY WAY, SHAPE OR FORM. IF ANY DAMAGES DO OCCUR, THE CONTRACTOR SHALL REPORT TO THE VZW CONSTRUCTION MANAGER IMMEDIATELY! IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN THE ROOFING SYSTEM IN ITS EXISTING CONDITION DURING CONSTRUCTION. WE PLAN APPRC?VAL Pemdt Number: Approved'By Date- -- ;:; Comments: _� , - ,Oe_ t- a M, f-1At DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. ' J<4 O� of wAsk CO No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Implementation Team: Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: PROPOSED • PL4,11 Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 A-2 VERIZON WIRELESS WALL MOUNTED ANTENNA MOUNT 22"x34" SCALE: 1/4" = l'-0" 11"x17" SCALE: 1/8" = l'-0" r 22"x34" SCALE: 1/4" = 1'-0" 11"xl7" SCALE: 1/8" = 1'-0" 4, 3' 2' 1' 0" 4' 20 O \------1----------------------------------------- ----=----------- ---------------------------- I I I VERIZON WIRELESS WALL I MOUNTED CONDUITS: (2) 2" EMT FOR FIBER & �• —®� — , POWER TO ANTENNAS I -EXISTING ROOF ENLARGED ROOF PLAN @ NODES 1 & 2 141 11"xl7"SCALE: 1/2 SCALE: 1 " "1'V-0" ENLARGED ROOF PLAN @ NODE 3 1 2 1 11"x17" SCALE: 3/32" AN on L i < L / A< 1< 44I - — , 4- I— _ I!< / { IL I I I <. .-.. IS t 1 kL L'I< I.< 44 L i{ € . . 1<4 f< ................ . . . ......... .............. . ......................... ........... 3" MIN - TYP 4'-0" SQUARE x 6" DEEP CONCRETE FOOTING W/ #5 @ 8" O.C. EW, CENTERED 1" CHAMFER EDGE - TYP. 5/8" 0 EXP. ANCHORS (MIN 4 PER CABINET) COORDINATE W/ CABINET MANUFACTURER SITE PLN APPROV, Permit Number: —1 rQ " I In G I APProved'By: Date: --��� p.Q 1 p ^- -- 3 VERIZON WIRELESS WALL MOUNTED CONDUITS: • (2) 2" EMT FOR FIBER & POWER TO ANTENNAS • (1) 2" EMT FOR POWER • (1) 2" EMT FOR FIBER PAINT CONDUITS AND ALL HARDWARE TO MATCH EXISTING BUILDING COLOR 4' 2'Si0" 4' ENLARGED EQUIPMENT AREA ELEVATION 11 DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Client: verizonv I Implementation Team: 1 I A&E Team: CONSULTING INC 11 Project Info: WALMART SMALL CELL I BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: ENLARGED PLANS • ELEVATIONS Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 A-3 4' 3, 2' 1' 0" 4' �7F FRP ANGLE 4x4x1/4 EA CORNER WITH 3/4" FRP ,„ FRP ANGLE 4x4x1/4 EA DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL 3_0 BOLT-TYP CORNER WITH 2 DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR ( ) 3/4" OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK FRP BOLTS - TYP SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION, I I 10'-0"Of 0 — — 1/4" FRP PANEL WAS�f FRP ANGLE 4x4x1/4 �z w z BOTTOM & TOP 6'-0" 3'-0" 496 yy ONAL E FRP SHROUD ANCHORED TO WALL W/ (6) ' — — = _ @ 3/8" 0 THREADED ROD, EMBED 2" WITH _ _ —_ —_ HILTI HY-70 ADHESIVE (USE SCREEN TUBE IF CELLS NOT GROUTED - ANCHORS TO FRP ANGLE 4x4x1/4 EA I ANTENNA I BE LOCATED IN CENTER OF CELL: 4" CORNER WITH 3/4" FRP OVP — — —_ I FROM TOP, BOTTOM & EDGE OF BLOCK) _ No. Date Revision BOLT-TYP 0 I RRUS32 RRUS32 LO o Ra ca A 03/30/16 90 /o CD REVIEW SET PSU AC 08 PSU AC 08 I I I o B 05/24/16 100% CD REVIEW SET 1-5/8" x 1-5/8" GALV UNISTRUT ANCHORED ® ® _ TO WALL W/ (3) 3/8" 0 THREADED ROD, I O O C 07/26/16 ANTENNA REVISION I EMBED 2" WITH HILTI HY-70 ADHESIVE (USE SCREEN TUBE IF CELLS NOT I I PROVIDE 6" STAND-OFF 0 08/09/16 ANTENNA SHROUD REVISION GROUTED) I FOR ANTENNAS I 1 09/13/16 100% SIGNED CD SET 2 I I I I - - — — — — — — — — — — — — — — — — — — @ PROVIDE 6" STAND-OFF Client: FOR ANTENNA @ NODE 2 — — FRP ANGLE 4x4x1/4 EA EXISTING C U­//"� CORNER WITH (2) 3/4" 9f-011 WALL I FRP BOLTS - TYP SHROUD OPEN @TOP FRP FINISH AND COLOR TO MATCH verizon AND BOTTOM EXISTING BUILDING 22"x34" SCALE: 3/4" = 1'_0" ANTENNA SHROUD - E L E V WITHOUT FRP PANEL 4 22"x34" SCALE: 1-1/2" = 1'-0" 11 "x17" SCALE: 3/8" = 1'-0" 1' 6" 0" 1' 11 "x17" SCALE: 3/4" = 1'-0" 1' 6" 0' 11 ANTENNA SHROUD — S E V T I O N Implementation Team: BLACK ROCK SITE P N APPROVAX Permit dumber• - Approved A&E Team: 10'-0" 100 PPro Y� Date: -- Comments: �, �_ i � , e1er a ((W) FRP SHROUD ANCHORED TO WALL W/ (6) +" 0 1 SScc•�iGC . THREADED ROD, EMBED 2" WITH HILTI HY-70 ADHESIVE (USE SCREEN TUBE IF CELLS NOT GROUTED - I _ _ _ _ _ _ _ _ _ _ _ ANCHORS TO BE LOCATED IN CENTER OF CELL: 4" /---EXISTING C U �— FROM TOP, BOTTOM & EDGE OF BLOCK) WALL CONSULTING _ I 3 FRP ANGLE 4x4x1 /4 EA CORNER WITH 3/4 FRP ...... _...... ..._............... BOLT-TYP I � _ Project Info: WALMART SMALL CELL I o BROOK LAKE I I01 34520 16TH AVE S FEDERAL WAY, WA 98003 FRP ANGLE 4x4x1/4 1 /4" FRP PANEL .............. I . . . . __._._.__.._._.. . I.._.__.._. FRP ANGLE 4x4x1/4 EA BOTTOM & TOP W/ 3/4" I _ — I CORNER WITH 3/4" FRP FRP BOLT a Drawing Title: - I BOLT-TYP SHROUD OPEN @ TOP AND BOTTOM co 1/4" FRP PANEL ENLARGED PLANS & ELEVATIONS FRP FINISH AND COLOR TO MATCH FRP ANGLE 4x4x1/4 EACORNER WITH (2) 3/4" FRP ANGLE 4x4x1/4 EA EXISTING BUILDING CORNER WITH (2) 3/4" FRP BOLTS -TYP Project Number: Date: FRP BOLTS -TYP FRP ANGLE 4x4x1/4 5-0"5'-0" 09/13/16 Drafter: Designer: BOTTOM & TOP W/ 1/4" RM RM FRP PANEL 10'-0" Project Manager: Professional of Record: AM RJ FRP FINISH AND COLOR TO MATCH Revision No: Sheet No: EXISTING BUILDING 22"x34" SCALE: 3/4" =1'-0" ANTENNA SHROUD - 22"x34" SCALE: 3/4" =1'-0" A-4 ANTENNA SHROUD - PLAN VIEW 1 11"x17" SCALE: 3/8" = 1'-0" 1' 6" 0" 1' E L E VAT I O N 2 11"x17" SCALE: 3/8" = 1'-0" 1' 6" 0" 1' Elm ................. TOP OF PARAPET 23'-10"± AGL ANTENNA TIP HEIGHT 23'-10"± AGL TOP OF PARAPET 25'-3"± AGL ANTENNA TIP HEIGHT 25'-3"± AGL AM PROPOSED VERIZON WIRELESS ANTENNA, RRU & OVP BEHIND 4 FRP SHROUD A-4 d. -__ _ _ _ —.` - - t a-'4 .. 4.! < /14 4 r .<. .. <a/y c / ......_tx.... .... _:.......................... .................:...._ ... .:.....< ....< .......-.............5 .<............... a ._ _... ............ .:.... ...... __.................... r 4 — __.. _— __—._..._ A............. _ �_ ..... ............ __,..__ ............... 41 41, 4 s 4.< 1 Y q 4 /.' / i r PARTIAL - ENLARGED ELEVATION (LEFT SIDE) TOP OF PARAPET 29'-0"± AGL ANTENNA TIP HEIGHT 29'-0"± AGL 22"x34" SCALE: 3/32" = 1'-0" 11"x17" SCALE: 3/64" = 1'-0" 8' 4' 0" 8' DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND 2 2 SPECIFICATIONS REMAIN THE PROPERTY OF ACOM A-4 ARF-1-7 CORPORATION. PROPOSED VERIZON WIRELESS ANTENNA, RRU & OVP BEHIND FRP SHROUD ..............__._....... _........ ._......_ _ _ _ ..._ W_..__._...._v.._....... _ ....... ..___.._....... -........-___................ _.__._..._.._ ..._...__.._._ - --- - __-\ l < 1 ; { F 4 4 / /:` 4 a / ' d { r ./� r PARTIAL - ENLARGED REAR ELEVATION NOTE: PROPOSED VERIZON WIRELESS ANTENNA SHROUD PAINTED TO MATCH BUILDING SUE PLAN ApppOVAL `Pel'ttdt Number:. Approved By: Date: PARTIAL - ENLARGED FRONT ELEVATION HJ� WASkI �� OF �v �z GM� Z 496 S ONAL E - No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - CIS lent: ve r i z U'Off6' nv'I Implementation Team: Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: NOT Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 A-5 GENERAL ELECTRICAL NOTES 1. GENERAL EXAMINE THE SITE CONDITIONS VERY CAREFULLY AND THE SCOPE OF PROPOSED WORK TOGETHER WITH THE WORK OF ALL OTHER TRADES AND INCLUDE IN THE BID PRICE ALL COSTS FOR WORK SUCH AS EQUIPMENT AND WIRING MADE NECESSARY TO ACCOMMODATE THE ELECTRICAL SYSTEMS SHOWN AND SYSTEMS OF OTHER TRADES. SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PERFORMED UNDER THIS CONTRACT. PERFORM DETAILED VERIFICATION OF WORK PRIOR TO ORDERING THE ELECTRICAL EQUIPMENT AND COMMENCING CONSTRUCTION. ISSUE A WRITTEN NOTICE TO THE CONSULTANT OF ANY DISCREPANCIES. OBTAIN ALL PERMITS, PAY ASSOCIATED FEES AND SCHEDULE INSPECTION. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, INSURANCE, AND SERVICES TO COMPLETE THIS PROJECT IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND PRESENT IT AS FULLY OPERATIONAL TO THE SATISFACTION OF THE OWNER. CARRY OUT WORK IN ACCORDANCE WITH ALL GOVERNING STATE, COUNTY AND LOCAL CODES AND O.S.H.A. PRIOR TO BEGINNING WORK COORDINATE ALL POWER AND TELCO WORK WITH THE LOCAL UTILITY COMPANY AS IT MAY APPLY TO THIS SITE. ALL WORK TO COMPLY WITH THE RULES AND REGULATIONS OF THE UTILITIES INVOLVED. FABRICATION AND INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEM SHALL BE DONE IN A FIRST CLASS WORKMANSHIP PER NECA STANDARD 1-2000 BY QUALIFIED PERSONNEL EXPERIENCED IN SUCH WORK AND SHALL SCHEDULE THE WORK IN AN ORDERLY MANNER SO AS NOT TO IMPEDE PROGRESS OF THE PROJECT. DURING PROGRESS OF THE WORK, MAINTAIN AN ACCURATE RECORD OF THE INSTALLATION OF THE ELECTRICAL SYSTEMS, LOCATING EACH CIRCUIT PRECISELY AND DIMENSIONING EQUIPMENT, CONDUIT AND CABLE LOCATIONS. UPON COMPLETION OF THE INSTALLATION, TRANSFER ALL RECORD DATA TO BLACK LINE PRINTS OF THE ORIGINAL DRAWINGS AND SUBMIT THESE DRAWINGS AS RECORD DRAWINGS TO THE CONSULTANT. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB ACCEPTANCE BY OWNER. ANY WORK, MATERIAL, OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE CONTRACTOR. GENERAL CONTRACTOR IS RESPONSIBLE FOR REQUESTING CONNECTION OF COMMERCIAL POWER FROM THE POWER COMPANY. ELECTRICAL CONTRACTOR SHALL COORDINATE THIS WORK WITH THE GENERAL CONTRACTOR. COORDINATE EXACT TELEPHONE REQUIREMENTS AND SERVICE ROUTING WITH LOCAL TELEPHONE COMPANY. APPLY FOR TELEPHONE SERVICE IMMEDIATELY UPON AWARD OF CONTRACT. 4. RACEWAYS AND BOXES SYMBOL DESCRIPTION CIRCUIT BREAKER Ep NON -FUSIBLE DISCONNECT SWITCH 1. ALL CONDUIT SHALL BE UL LABELED. OF FUSIBLE DISCONNECT SWITCH 2. ALL EMPTY CONDUITS INSTALLED FOR FUTURE USE SHALL HAVE A PULL CORD. - SURFACE MOUNTED PANEL BOARD 3. SHEET METAL BOXES SHALL CONFORM TO NEMA OS1; CAST -METAL BOXES SHALL CONFORM TO TR TRANSFORMER NEMA 81 AND SHALL BE SIZED IN ACCORDANCE WITH NEC UNLESS NOTED OTHERWISE. KILOWATT HOUR METER DENOTES CABLE OR CONDUIT —0 TURNING UP IN PLAN VIEW 5. GROUNDING DENOTES CABLE OR CONDUIT TURNING DOWN IN PLAN VIEW 1. ALL LIGHTNING PROTECTION AND SAFTEY GROUNDING OF' THE ELECTRICAL EQUIPMENT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE CURRENT NFPA STANDARDS AND JB JUNCTION BOX VERIZON WIRELESS STANDARDS PB PULL BOX TO NEC/TELCO STANDARDS 2. GROUND LUGS ARE SPECIFIED UNDER SECTION 3 "CONDUCTORS AND CONNECTORS". �H" oHU— OVERHEAD UTILITIES 3. ALL GROUND LUG AND COMPRESSION CONNECTIONS SHALL BE COATED WITH ANTI -OXIDANT AGENT, __Wr__UGr_ UNDERGROUND TELCO SUCH AS NO-OX, NOALOX, PENETROX OR KOPRSHIELD. --UV--UW— UNDERGROUND POWER 4. GROUND ALL EXPOSED METALLIC OBJECTS ON EQUIPMENT ROOM EXTERIOR. DENOTES REFERENCE NOTE 5. PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS. USE • EXOTHERMIC WELD CONNECTION STAINLESS STEEL HARDWARE THROUGHOUT. ■ MECHANICAL CONNECTION (eg LUG, C-TAP) 6. DO NOT INSTALL GROUND RING OUTSIDE OF LEASE AREA. GROUND ROD 7. REMOVE ALL PAINT AND CLEAN ALL DIRT FROM SURFACES REQUIRING GROUND CONNECTIONS, GROUND ROD WITH INSPECTION SLEEVES REPAINT TO MATCH AFTER CONNECTION IS MADE TO MAINTAIN CORROSION RESISTANCE. _F__T GROUND BAR PIN AND SLEEVE RECEPTACLE 8. ALL EXTERIOR GROUNDING CONDUCTORS INCLUDING EXTERIOR GROUND RING SHALL BE #2 AWG GROUND CONDUCTOR SOLID BARE TINNED COPPER UNLESS NOTED OTHERWISE. MAKE ALL GROUND CONNECTIONS AS SHORT AND DIRECT AS POSSIBLE. AVOID SHARP BENDS. THE RADIUS OF ANY BEND SHALL NOT BE HP MOTOZ W/ HORSEPOWER RATING LESS THAN 8" AND THE ANGLE OF ANY BEND SHALL NOT EXCEED 900. GROUNDING CONDUCTORS SHALL BE ROUTED DOWNWARD TOWARD THE BURIED GROUND RING. 9. BOND ALL EXTERIOR CONDUITS, PIPES AND CYLINDRICAL METALLIC OBJECTS WITH A PENN-UNION GT SERIES CLAMP, BLACKBURN GUV SERIES CLAMP OR A BURNDY GAR 3900BU SERIES CLAMP ONLY, NO SUBSTITUTES ACCEPTED. 10. ALL GROUND CONNECTIONS SHALL BE APPROVED FOR THE METALS BEING CONNECTED. DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. _10 H' i WA$�����'� NAL No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Client: verizonv Implementation Team: 2. BASIC MATERIALS AND METHODS 11. ALL EXTERNAL GROUND CONNECTIONS SHALL BE EXOTHERMICALLY WELDED. ALL EXOTHERMIC A ABBREVIATIONS ALL ELECTRIC AL WORK SHALL CONFORM TO THE EDITION OF THE NEC ACCEPTED BY THE LOCAL JURISDICTION AND TO THE APPLICABLE LOCAL CODES AND REGULATIONS. WELDS TO EXTERIOR GROUND RING SHALL BE THE PARALLEL TYPE, EXCEPT FOR THE GROUND RODS WHICH ARE TEE EXOTHERMIC WELDS. REPAIR ALL GALVANIZED SURFACES THAT HAVE BEEN DAMAGED BY EXOTHERMIC WELDING. USE SPRAY GALVANIZER SUCH AS HOLUB LECTROSOL 415-501. AFG ABOVE FINISHED GRADE ALL MATERIALS AND EQUIPMENT SHALL BE NEW. MATERIALS AND EQUIPMENT SHALL BE THE STANDARD AIC AMPERE INTERRUPTING CAPACITY PRODUCTS OF MANUFACTURER'S CURRENT DESIGN. ANY FIRST-CLASS PRODUCT MADE BY A REPUTABLE MANUFACTURER MAY BE USED PROVIDING IT CONFORMS TO THE CONTRACT REQUIREMENTS AND MEETS THE APPROVAL OF THE CONSULTANT AND THE OWNER. 12. CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER WHEN THE BURIED GROUND RING IS INSTALLED SO THE REPRESENTATIVE CAN INSPECT THE GROUND RING BEFORE IT IS BACKFILLED WITH SOIL. BFG C BELOW FINISHED GRADE CONDUIT BLACK ROCK CRGB CELL REFERENCE GROUND BAR ARRANGE CONDUIT, WIRING, EQUIPMENT, AND OTHER WORK GENERALLY AS SHOWN, PROVIDING PROPER CLEARANCES AND ACCESS. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS AND FIT THE WORK IN EACH LOCATION WITHOUT SUBSTANTIAL ALTERATION. WHERE DEPARTURES ARE PROPOSED BECAUSE OF FIELD 13. FOR METAL FENCE POST GROUNDING, USE A HEAVY DUTY TYPE GROUNDING CLAMP OR EXOTHERMIC WELD CONNECTION TO POST. GROUND ALL FENCE POSTS WITHIN 6' OF EQUIPMENT. CU C/W COPPER COMPLETE WITH A&E Team: CONDITIONS OR OTHER CAUSES, PREPARE AND SUBMIT DETAILED DRAWINGS FOR ACCEPTANCE. D.T.T. DRY TYPE TRANSFORMER 09)) THE CONTRACT DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ALL OFFSETS, BENDS, FITTINGS AND ACCESSORIES ARE NOT NECESSARILY SHOWN. PROVIDE ALL SUCH ITEMS AS MAY BE REQUIRED TO FIT THE WORK 14• WHERE MECHANICAL CONNECTORS (TWO -HOLE OR CLAMP) ARE USED, APPLY A LIBERAL PROTECTIVE COATING OF AN ANTI -OXIDE COMPOUND SUCH AS NO-OX, NOALOX, PENETROX OR KOPRSHIELD ON ALL CONNECTORS. EC G EMPTY CONDUIT GROUND &OM7 TO THE CONDITIONS. GE GROUNDING ELECTRODE CONSULTINGI MAINTAIN ALL CLEARANCES AS REQUIRED BY NEC. GEC GROUNDING ELECTRODE CONDUCTOR SEAL AROUND CONDUITS AND AROUND CONDUCTORS WITHIN CONDUITS ENTERING THE BUILDING WHERE 6. OVERCURRENT & SHORT-CIRCUIT/GND FAULT PROTECTION (IF APPLICABLE) GRC GALVANIZED RIGID CONDUIT PENETRATION OCCURS WITH A SILICONE SEALANT TO PREVENT MOISTURE PENETRATION INTO 1. CONTRACTOR SHALL RECORD LOAD READINGS WHEN SITE POWER ORIGINATES FROM A 30 SERVICE MTS MANUAL TRANSFER SWITCH BUILDING/SHELTER. SILICONE SEAL AROUND ALL BOLTS AND SCREWS USED TO SECURE EQUIPMENT TO EXTERIOR OF BUILDING. 3. CONDUCTORS AND CONNECTORS TO MONITOR & ASSURE A BALANCED LOAD AT THE PRIMARY SUPPLY. RECORDS SHALL BE PROVIDED TO THE SITE/FACILITY OWNER. CONTRACTOR SHALL CONSULT MANUFACTURER'S PLANS, SHOP DRAWINGS AND SPECS FOR INDOOR/OUTDOOR EQUIPMENT LOCATION & INSTALLATION. ELECTRIC SERVICE SHALL BE IN COMPLIANCE WITH ALL RULES & REGULATIONS OF THE UTILITY CO. ELECT. CONTRACTOR SHALL PROVIDE EQUIPMENT WITH HIGHER SHORT-CIRCUIT FAULT CURRENT RATINGS (kA.I.C.) AS REQUIRED TO MATCH & EXCEED UTILITY CO. AVAILABLE SYMMETRICAL & ASYMMETRICAL FAULT CURRENT LEVELS. FUSES IN SERVICE SWITCHES SHALL BE CLASS "RK1", CURRENT LIMITING NEC O/H RNC SD SE NATIONAL ELECTRICAL CODE OVERHEAD RIGID NON-METALLIC CONDUIT (SCHEDULE 80 PVC) SERVICE DISCONNECT SWITCH SERVICE ENTRANCE Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 UNLESS NOTED OTHERWISE, ALL CONDUCTORS SHALL BE COPPER, MINIMUM SIZE #12 AWG, WITH THERMOPLASTIC INSULATION CONFORMING TO NEMA WC5 OR CROSS -LINKED POLYETHYLENE INSULATION CONFORMING TO NEMA WC7. (TYPES THHN OR THWN-2). INSULATION SHALL BE RATED FOR 90°C CONDUCTORS TYPE, 200 kA.I.C., NON -TIME DELAY, DISCONNECT SWITCHES TO HAVE REJECTION CLIPS, UNLESS INDICATED OTHERWISE. ELECTRICAL EQUIPMENTS & PROTECTIONS SHALL BE STANDARD kAIC RATED HIGHER THAN INCOMING EQUIPMENT AND/OR UTILITY CO. kAIC RATE AND CONSIDERING SN TGB SOLID NEUTRAL TELCO GROUND BAR Drawing Title: GENERAL SHALL BE COLOR CODED IN ACCORDANCE WITH NEC. ELECTRIC MOTORS FAULT CONTRIBUTION. CONTRACTOR SHALL NOT BEGIN CONSTRUCTION UNTIL TEGB TOWER EXIT GROUND BAR ELECTRICAL ALL CONDUCTORS USED FOR GROUNDING SHALL BE COPPER AND SHALL HAVE GREEN INSULATION EXCEPT WHERE NOTED. THIS MANDATORY REQUIREMENT IS MET. IF NEW LOAD IS ADDED CONTRACTOR SHALL VERIFY & CONFIRM BEFORE CONSTRUCTION THAT TOTAL UTILITY SERVICE LOAD SHALL KEEP EQUAL TO (125% MAX. DEMAND+ NEW LOAD)< 80% SERVICE ENTRANCE CONDUCTORS/MAIN OVER CURRENT TR TVSS TRANSFORMER TRANSIENT VOLTAGE SURGE SUPPRESSOR NOTES FOR COPPER CONDUCTORS #6 AWG AND SMALLER USE 3M SCOTCH-LOK OR T&B STA-KON COMPRESSION TYPE PROTECTION CAPACITY, WHICHEVER RATING IS LOWER. LIGHTING SHALL MEET NEC, IESNA AND/OR TYP TYPICAL CONNECTORS WITH INTEGRAL OR SEPARATE INSULATION CAPS. FOR COPPER CONDUCTORS LARGER THAN #6 AWG USE SOLDERLESS, IDENT HEX SCREW OR BOLT TYPE PRESSURE CONNECTORS OR DOUBLE COMPRESSION C-CLAMP CONNECTORS, UNLESS SPECIFIED OTHERWISE ON DRAWINGS. FAA STANDARDS IF APPLICABLE. PHOTOMETRIC LEVELS SHALL COMPLY WITH LOCAL, STATE & FEDERAL RULES. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESSIBLE AREAS ONLY. THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND TELE- U/ U/G WEATHERPROOF - NEMA 3R UNDERGROUND Project Number: Date: 09/13/16 PHONE UTILITY COMPANIES. PPC POWER PROTECTION SHELTER Drafter: Designer: UNLESS NOTED OTHERWISE ALL LUGS SHALL BE TIN PLATED COPPER, TWO -HOLE, LONG BARREL, RM RM Project Manager: Professional of Record: COMPRESSION TYPE. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. SPLICES AM RJ Revision No: Sheet No: ARE NOT ACCEPTABLE. IF SPLICES ARE UNAVOIDABLE PRIOR APPROVAL FROM THE ENGINEER MUST BE OBTAINED. 1 E-0 I22"x34" SCALE. 1/32" = 1'-0" 11"x17" SCALE: 1/64" = 1'-0" :::::::: F 7 -i t----------------------- IIIII VERIZON WIRELESS CONDUITS MOUNTED ON SLEEPERS: N PROPOSED VERIZON WIRELESS EQUIPMENT CABINET AND LOAD CENTER MOUNTED ON CONCRETE PADS VERIZON WIRELESS CONDUITS ROUTED INSIDE BUILDING: (2) 2" EMT CONDUIT FOR POWER & FIBER (1) 2 EMT CONDUIT FOR ANTENNAS I,- ; T rill I _ I � E , �T � I i_ __J El I 1 I_ I ----, El _� niiG l !/ I ..._...................... El Il�t L L\ VERIZON WIRELESS CONDUITS MOUNTED ON SLEEPERS: © F7, F7 �,177 I (1) 2 EMT CONDUIT FOR ANTENNAS q F1 E ;,Ei Ell II lle I o EXISTING ELECTRICAL ROOM AND MPOP it 1 -T IL �y F77, �i L E i ® mi�;;l;; 1"I E SHE PLAN APPROVAL Pelt Number: — U S a7 — 00- k-0 Approved By: GA) Date: — o Comments: T� DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. K . J4 o� GF WASH NAL No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Implementation Team: BLACK ROCK Project Info: WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Drawing Title: PROPOSE® ELECTRICAL SITE PLAN Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No: Sheet No: 1 E®1 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE 22"x34" SCALE: NOT TO SCALE 11 "x17" SCALE: NOT TO SCALE 0.2273 DIA. MAX. 12" TO 24" ANTENNA CABLE WEATHERPROOFING KIT (SEE NOTE 3) CABLE GROUND KIT #6 AWG STRANDED CU WIRE WITH 600V, THWN INSULATION (GROUNDED TO GROUND BAR - SEE NOTE 1 & 2) NOTES: 1 DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR 2. GROUNDING KIT TO BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER 3. WEATHER PROOFING SHALL BE (TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER CONN OF GRID KIT TO ANTENNA CABLE 4 22"" SCALE: NOT TO SCALE 11"xl7"SCALE: NOT TOSCALE ANTENNA(S) COAXIAL GROUND KITS RADIOS IN MAIN CABINET :U I L cT LOAD CENTER �A RF #4 AWG CU. GROUND LEADS c \ DIRECTLY TO MAIN GROUND BAR \ \ c c c TAP #4 GROUND DIRECTLY TO ANTENNA 6" LONG GROUND BAR MAY BE INSTALLED IF 2 OR MORE ANTENNAS ARE UTILIZED #4 AWG STIR TO #2 AWG STIR COMPRESSION CONNECTOR #2 AWG CU, MAIN GROUND LEAD MOUNTED DIRECTLY TO POLE W/ C CLIPS EVERY 2'-0" 0 ,ONNECT TO SCL VERTICAL GROUND, IF 3ROUND IS NOT PRESENT PLACE NEW #2 AWG CU. GROUND WIRE 5/8" X 8' LONG COPPER CLAD STEEL GROUND ROD ERICSSON MRRU + - RF DISCONNECT SWITCH WITH SAFETY LOCKOUT MOUNTED TO SIDE OF LOAD CENTER 1" CONDUIT SCH 40 3#6 CU THHN/THWN TO SCL WALMART PROVIDED SERVICE DISCONNECT BRONZE GROUND CLAMP - - 518" DIA. X 8FT COPPER CLAD STEEL GROUND ROD ERICSSON CABINET MOUNTED RADIOS MRRU + - _ DC POWER CORD QTY. (2) #10-2 SOOW, 00.453"-0.606" f- PAD MOUNTED DUDLIK CABINET G NLDI LD2 GFCI DUPLEX RECEPTACLE 15A, 125V, 2P, Loa 0 3W NEMA 5-15R WEATHER RESISTANT TYPE WITH WEATHERPROOF WHILE -IN USE COVER 3/4" LIQUID TIGHT FLEXIBLE METAL CONDUIT 5#10 & 2#10 GRD CU THHN/THWN CABINET MOUNTED SERVICE DUTY LOAD CENTER 100A, FIXED a MAINS, 2P, 120/240V CIRCUIT BREAKERS WITH NEUTRAL & GROUND BUS NEMA 3R ENCLOSURE 3/4" LIQUID TIGHT FLEXIBLE METAL CONDUIT 3#4 CU THHN/THQN AWG CU. GROUND WIRE IN. GRADE ONE -LINE POWER DIAGRAM 13 NOTE: CONTRACTOR TO USE KOPR-SHIELD, PENETROX TYPE "E" AT THESE CONNECTIONS HEAT SHRINK ALL OUTSIDE NEW COAXIAL GROUND KITS W/ LONG LUG CONNECTIONS BARREL COMPRESSION LUGS (DOUBLE LUGS) TO BE INSTALLED BY ANTENNA [CONTRACTOR WITH HEAT SHRINK " SCALE: NOT TO SCALE GROUNDING SCHEMATIC 121 11"x1�" SCALE: NOT TO SCALE TO GROUND KIT NEW 4" x 24" x 1/4" thk COPPER GROUND BAR. CONSTRUCTION MANAGER TO VERIFY EXACT LOCATION AND INSTALLATION IN FIELD 01 10 00 o CO o O O O 0 0 00 0 000 00 0o000 O 00 O 0 0 00 O OOOQO O 0 0 0 O O O O O O O o O O O O O o TYPE HS CADWELD - o #410 CU LEAD TO GROUND LOOP 24" VERIFY IN FIELD NOTES: 1. ALL HARDWARE 8-88 STAINLESS STEEL INCLUDING BELLVILLES COAT MATING SURFACES WITH KOPR-SHIELD BEFORE ATTACHMENT 2. FOR GROUND BOND TO STEEL ONLY: INSERT A TOOTH WASHER BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH KOPR-SHIELD 3. ALL HOLES ARE COUNTERSUNK 1/16" 4. ALL LUGS ARE DOUBLE HOLED 5. HEAT SHRINK ALL OUTSIDE LUG CONNECTIONS MASTER GROUND BAR DETAIL 11 DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. '� � • ill', No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - Ciient: verizon, Implementation Team: A&E Team: CONSULTINGINC. Project Info. WALMART SMALL CELL BROOK LAKE 34520 16TH AVE S FEDERAL WAY, WA 98003 Project Number: Date: 09/13/16 Drafter: Designer: RM RM Project Manager: Professional of Record: AM RJ Revision No. Sheet No: 1 E-2 DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK 2-1/2 O GALVANIZED SCHEDULE 40 PIPE x 96" MECHANICAL DOWN TILT KIT BY ANTENNA MANUFACTURER M.-.O NIOTF- \A/AI I ATTAC.HI\AFNIT CHAI I PROPOSED ANTENNA AND COAX SCHEDULE ANTENNA AZIMUTH TIP HEIGHT NUMBER OF ANTENNAS VENDOR MODEL DIMENSIONS ELEC TILT MECH TILT NUMBER OF FEEDERS FEEDER TYPE FEEDER LENGTH ADDITIONAL EQUIPMENT DIM 1 TDIM 2 DIM 3 NODE 1 0° 25'-3" 1 AMPHENOL HTXCWW4513F000 24.1" 16.2" 7.3" 0° 0° 1 HYBRID 382' ± NODE 2 270° 23'-10" 1 AMPHENOL HTXCWW4513F000 24.1" 16.2" 7.3" 0° 0° 1 HYBRID 385' ± NODE 3 145° 29'-9" 1 AMPHENOL HTXCWW4513F000 24.1" 16.2" 7.3" 0° 01 1 HYBRID 1009' ± 2-1/2" O GALVANIZED SCHEDULE 40 I PIPE x 96" f Q i i ANTENNA MOUNT BRACKETS TOP VIEW P1000 UNISTRUST BY ANTENNA MANUFACTURER ANCHORED TO WALL (TYP) FRONT SIDE PANEL ANTENNA 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE PROPOSED ANTENNA MOUNTING DETAILS 3 TOP MANUFACTURER:RAYCAP SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CORPORATION. No. Date Revision A 03/30/16 90% CD REVIEW SET B 05/24/16 100% CD REVIEW SET C 07/26/16 ANTENNA REVISION 0 08/09/16 ANTENNA SHROUD REVISION 1 09/13/16 100% SIGNED CD SET 2 - - 3 - - MODEL: RRFDC-3315 10.5" HEIGHT: 13.58" Client: WIDTH: 10.5" 00 00 DEPTH:8.15" LID CY) C15 WEIGHT: 14.0 LBS (WITH MOUNT) Ra ca COLOR: DARK GRAY ® a. PROPOSED VERIZON WIRELESS PANEL . ANTENNA (TYP OF 3) ­ueriz 8.15 tV Q o 0 Implementation Team: 0 O 22"x34" SCALE: NOT TO SCALE z /� :_.. 11"x17"SCALE. NOT TOSCALE O \ / V P (RAYCAP) SPECIFICATIONS `T NODE 2 AZ: _____________ OR -------------�_ A 270° z `1 01 12 64�� 7 64 MANUFACTURER: ERICSSON i -I i MODEL: RRUS32 W/ PSU AC 08 HEIGHT: 27' 64 WIDTH: 12 i "I Ell z x z N z ® �v DEPTH:7�4" BLACK ROCK WEIGHT: 65 LBS z llI x z 0 z COLOR: OFF-WHITE 1` 0 z z z N C z i 12 64cvo .__._ ® z z A&E Team: CN N PSU AC 08 UNIT z N z z N z z L_ z rA&OM7 I , I1z N Ir :z� y; �� l� z CONSULTING INC. ry1v .. ... E M, z '[5 ® z 27 22"x34" SCALE: NOT TO SCALE R R U SPECIFICATION S � � .,�� — _- � � 'xl � �� XI 11"x17" SCALE: NOT TO SCALE I z z z X z z �Z NProject Info: z Ix 'A Mz WALMART SMALL CELL MANUFACTURER: CHARLES z zBROOK LAKE MODEL: PM63922RF - 34520 16TH AVE S 21-811 HEIGHT: 7'-5" z z z z X z '� z z z FEDERAL WAY, WA 9$003 WIDTH: 2'-8" 21-811 DEPTH: 2'-8" i z PROPOSED VERIZON WIRELESS PANEL z ® z z WEIGHT: 500 LBS ANTENNA (TYP OF 3) o COLOR: OFF-WHITE i _ Drawing Title: • � • VERIFY PROPER VOLTAGE I r PROPOSED PRIOR TO ORDERING �-..... �� -- �' ANTENNA • 2'-811 20 SrM p ,APPROVAL CONFIGURATION . _ s Permit Number: t 4 Approved By: Date: I 117 Project Number: Date: Comments: _^�� 09/13/16 iv � t 55"gC4 7 GC Drafter: Designer: . ... RM RM • Project Manager: Professional of Record: • AM RJ Revision No: Sheet No: PLAN VIEW FRONT VIEW SIDE VIEW NORIH 1 RF-1 1 "xl 7" SCALE: NOT TO SCALE CHARLES CABINET SPECIFICATIONS 2 11 "x34,' SCALE: NOT TO SCALE. PROPOSED ANTENNA CONFIGURATION 1 11 x17 SCALE: NOT TO SCALE 11 x17' SCALE: NOT TO SCALE