06-100790NOTES • HANDRAIL NOT REQUIRED W/ RISE LESS THAN OR EQUAL TO 6 INCHES, OR A RUN LESS THAN • HANDRAIL$ REQ AT SLOPES GREATER THAN 1: 20- HANDRAILS TO EXTEND MIN IV BEYOND TOP 4 BOTTOM SEGMENT • MAX RAIL OPENINGS NOT TO EXCEED 4' • RAIL ENDS SHALL BE RETURNED OR TERMINATE IN NEWEL POST OR SAFETY TERMINAL • GUARDRAIL t ATTACHMENTS SHALL BE CAPABLE OF RESISTING 20 plf WORM LOAD ■ TOP RAIL • MAX SLOPE SHALL BE 1 VERTICAL IN 12 HORIZONTAL • MIN WIDTH OF RAMP SHALL BE 44 ' FOR EXTERIOR RAMPS EDGE PROTECTION 2' MIN HIGH x 6' WIDE REQ. W/ SLOPES GREATER THAN 1: 20 OR MORE THAN 1/2 INCH ABOVE ADJACENT GRADE 48- MIN. v 1:12 l 1:8 SLOPE SLOPE Fire hydrants shall to and during the time dof serviceable prior construction. Fire apparatus access roads shall be installed and made serviceable prior to and during the time of construction. I.F.C. Section 501.4 Fire extinguishers shall be selected, installed and maintained in accordance with I.F.C. Section 906 and N.F.P.A. 10. APPROVED SOUTH KING FIRE ACCESSIBILITY SIGN SEE NOTE 10 PEDESTRIAN ROUTE . X and TYP. PAVEMENT-/ SYMBOL �2w 110 Handicapped Parking Only 0 WHEEL STOP tMIW 1:8 MAX. SIDE SLOPE PERMANENT STRIPING 9'—W 1, — MIN. V60MIN. AT TYP. ACCESSIBLE PARKING STALL. 8'-0' MIN. AT VAN ACCESSIBLE PARKING STALL s' ALUMINUM SIGN :E NOTE 10 SQ. STEEL SST FINISH AS =R SPECIFICATIONS DIA. CONC. FTG. e ACCESSIBLE PARK I NG 57,4LL/5I6N Ld Q SW EXIST IF SIDEWALK tP Dtf'' — — — ' PROPERTY— --- PR PO S E A-o- -- EDICATI ON — E PRE SSO i ' ° ° • 5'°LANDSCAPING °TYPE III • EXIST REQ 50 Fr SIDEWALK83 SQ.FT. �• 72.0, 0 / LOOR LE - 231.6 drive thru 114 - - i ATUM E 229.5 EXIST 1 w / SANDSC ATTURALSOIllSIDEWoL �/W/ LANDSCAPE w Sgt ' -CL m chC) / LAND CAPE =CY bel rode Q+ Nobi �7_ Z c° / /tJ SIGNS AND IDENTIFICATION NOTES I. ACCESSIBLE PARKING SPACES SERVING A PARTICULAR BUILDING SHALL BE LOCATED AS NEAR AS PRACTICAL TO A PRIMARY ENTRANCE AND ON THE SHORTEST ACCESS- 15LE ROUTE OF TRAVEL FROM PARKING TO A PRIMARY ENTRANCE. 2. WHERE SINGLE ACCESSIBLE PARKING SPACES ARE PROVIDED, THEY SHALL BE 14' WIDE AND OUTLINED TO PROVIDE A S' PARKING AREA AND A 5' LOADING AND UNLOADING ACCESS AISLE ON THE PASSENGER SIDE OF THE VEHICLE. IN ADDITION, SEE NOTE 5. 3. NOT USED 4. THE MINIMUM LENGTH OF AN ACCESSIBLE PARKING SPACE SHALL BE 16'. 5, ONE IN EVERY EIGHT ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, SHALL BE SERVED BY AN ACCESS AISLE 156' WIDE MINIMUM AND SHALL BE DESIGNATED VAN ACCESSIBLE. 6. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES SHALL BE THE MINIMUM POSSIBLE AND SHALL NOT EXCEED 1/4' PER FOOT IN ANY DIRECTION. SPOT GRADE ELEVATION. i. IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED AND LOCATED TO PREVENT ENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS. 6. RAMPS SHALL NOT ENCROACH INTO ANY PARKING SPACE, WITH THE EXCEPTION OF A TRANSITION RAMP FROM A LOADING/ INLOADING AREA TO AN ADJACENT SIDEWALK THE TRANSITION RAMP SHALL BE A MINIMUM OF 48' IN WIDTH, A MAXIMUM OF 60, IN LENGTH, WITH A MAXIMUM SLOPE OF 1.12. S. ACCESSIBLE PARKING SPACES SHALL BE SO LOCATED THAT PERSONS WITH DISABILITIES ARE NOT COMPELLED TO WHEEL OR WALK BEHIND PARKED CARS OTHER THAN THEIR OWN. 10. PARKING SPACE IDENTIFICATION: A. ADA: ACCESSIBLE PARKING SPACES SHALL BE DESIGNATED AS RESERVED BY A SIGN SHOWING THE SYMBOL OF ACCESSIBILITY (AND) SHALL HAVE AN ADDITIONAL SIGN 'VAN ACCESSIBLE' MOUNTED BELOW THE SYMBOL -(LOCATE SIGN SO THAT IT) CANNOT BE OBSCURED BY A VEHICLE PARKED IN THE SPACE. 11, THE SURFACE OF EACH ACCESSIBLE PARKING SPACE OR STALL SHALL HAVE A SURFACE IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWING SCHEMES: A. BY OUTLINING OR PAINTING THE STALL OR SPACE IN BLUE AND OUTLINING ON THE GROUND IN THE STALL OR SPACE IN WHITE OR SUITABLE CONTRASTING COLOR A PROFILE VIEW DEPICTING A WHEELCHAIR WITH OCCUPANTt OR B. BY OUTLINING A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON BLUE BACKGROUND. THE PROFILE VIEW SHALL BE LOCATED SO THAT IT IS VISIBLE TO A TRAFFIC ENFORCEMENT OFFICER WHEN A VEHICLE IS PROPERLY PARKED IN THE SPACE AND SHALL BE 36' HIGH BY 36' WIDE. (FIG. C 6 RIGHT) 320 th PEDESTRIAN ACCESS ST ry� EXIST — SIDEWALK 8!3423-- -- -- W- -5 — — — 5' ANDSCAPING • : 0 0 1 0 PEDEST IAN STAMS D CONIC1s'-0.: 0 0 ; i / _ 5'-0 x ry in g' 1111'-0' 9'-0" 3 C ' • L0 7 5 4 o/o z LA DSCAPE i ; LO lop 0), a �h�/�ej `ory o1 BENCH _ I / ELEa�nl�rir TURAL ASH �I 12'-0 '-0"/ W/ LANDSCAPE $ Q. 0 z 8 _ BSB �' W TA I . o 0 18'-2" 2 2 47 SQ. F Z I o / 01 F OOR LE EL- 232. �7° X 10 TRAC�fES ATUM LEV- 231 A C /G)S 7 YPE 1 • i � 0 � LANDS 11 BI o C > 91- ,� 0 m Oj a W � Z� TRASHY -� _ Q -01 Br -RECYCLE 13 01 I 20'-0" o '23" W 122.0 ° SEE SHT A-5 BSBL :ri 15'-0" M 27'-9" 49'-9" • � 48" FIR O V) Q° m z a 1 Jl_- N 88°34'23" 62.0 D�4TRIAN S— STAMPED CONIC LOCATED WITHIN LANDSC BUFFER TO PRESERVE SIGNIFICANT TREES— SEE LANDSCAPE PLAN TE PLAN CALE: 1 " = 20'-0" 20�,1'0" 0 i CV SW 320 TH ST DASH POINT PROJECT SITE STATE PARK Cn - Q SW 323rd PL VICINITY MAP N TS PROJECT DATA SITE AREA: 23,412 SQ.FT. ZONING: BN NEIGHBORHOOD BUSINESS — PARCEL #: 1421039095 SITE ADDRESS : 3200 47th Ave SW FEDERAL WAY, WA PROPOSED USE: RETAIL PERMITTED — BUILDING AREA: RETAIL 2547 SQ.FT. ESPRESSO 283 SQ.FT. PARKING REQUIRED: RETAIL 2547/ 300 = 8.5 ESPRESSO = 2 10.5 PROVIDED 13 % 7S MAX IMPERVIOUS COVERAGE: 80% ACTUAL +- 75% C) STREET SETBACK SIDE SETBACK REAR SETBACK LANDSCAPE — IBC CODE 2003/ WSBC 51-40 WA — CONSTRUCTION TYPE— V—B — OCCUPANCY M NOTE Zj SHEET INDEX MECHANICAL SCREEN 24" ABOVE TOP CIVIL �8 _ OF MECH UNITS W REMOVABLE METAL SCREEN SEE CIVIL ENGINEERING INDEX 2 ROOF TO COMPLE PLY SCREEN ALL MECH UNITS 0' 2 _ Authorization ® Ori final ReL ,,ri d'acen a� facet qgpA irrence Revision Qs Date Initials Date Zoning/Planning: � ' Public Works v Fire Departments King Co. Health Approval Verified Building/Structrual Issued By: 0 FROM ALL ADJOINING PROPERTIES N ARCHITECTURAL / STRUCTURAL SP-1 TITLE SHEET, PROJECT DATA, VICINITY MAP A-1 GENERAL / A-2 FLOOR PLAN TRASH ENCLOSU Nk. 1NSFU:Gfl0\ A-3 EXTERIOR ELEVATIONS 11176% �! :;(w— OWNER�&COMPANY DEVELOPER: A-4 RESTROOM PLAN- NOTES/ DOOR SCHEDULE IE JJIRED D. MOORE A-5 BUILDING SECTION/ STAIR SECTION/ DETAILS 9012 166th ST CT E AS-6 FOUNDATION PLAN PUYALLUP, WA 98375 AS-7 ROOF PLAN lFCN ON OF \AC (253) 219-1920 S-1 STRUCTURAL PLAN/ DETAILS/ NOTES MECHANICAL SEPARATE PERMIT DESIGNER: ELECTRICAL SEPARATE PERMIT 111M OF FE©EFM WAY GERRY SLICK DESIGN GROUP PLUMBING SEPARATE PERMIT now- it npuutlurry newel r%nam 1944 PACIFIC AVE- SUITE 307 TACOMA, WA 98402 Permit #0 6 - 10 0 7 9 0 - 0 0 � (253) 573-1562 Site address: 4615 SW 320th Street FAX 253) 573-1567 Project: New Retail Building K CONTACT: MARK PETERSON Name: MOORE RETAIL CENTER j Date:2/17/06 r FILE- "Ur'Sl7=-UU= f --�-�ArrKUVLU .. #39_-. .� VCL 8 U c� to L/ D h h f',RD-fl1 .i. r.Plf.,ARK r T E ,;rye i - �■r� V IMPORTANT This copyrighted plan may not be used or reproduces without the written permis lion of Gerry Slick Design Group. Gerry Slick Design Group does not assume liability for a home constructed from this plan. The pureh aser assumes all respons- ibility for following these instructions. 1. Contractor or builder must verify all dimensions before proceeding with construction. 2. This plan was designed tqr be marketed: throughout many municipalities. The purchaser must verify compli"i07 a with all local applicable building codes where the home is to be constructed. 3. Purchaser should have plans reviewed by a lic- ensed builder and struct- ural engineer for compli- ance to specific site con- ditions. 4. These plans shot be altered by other qualified designer, ; test, or structural e Plan No: OFF-400 Date: 02/10/2006 SP-1 REVIEWED•BY:•G