Loading...
23-103357s� Building - Commercial City of Federal Way Permit #:23-103357-00-CO - Community Development Dept y 33325 8th Ave S Federal Way, WA 98003 Inspection Request Line: (253) 835-3050 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name: BURLINGTON Project Address: 1751 S COMMONS Parcel Number: 762240 0015 Project Description: BLUEBEAM - Racking permit Owner Applicant Contractor Lender MERLONE GEIER PARTNERS KATHERINE AMAYA H J MARTIN & SON INC TENANT IS LENDER 457 SW 148TH ST SUITE 202 8370 WILSHIRE BLVD SUITE 330 320 S MILITARY AVE BURIEN WA 98166 BEVERLY HILLS CA 90211 GREEN BAY WI 54303-2202 Census Category: 437 - Commercial alt / add / conversion Includes: # 1 #2 43 #4 Occupancy Class: Construction Type: Occupancy Load: Floor Area (sq. ft.) Additional Permit Information Mechanical to be Included? ..................................... No Plumbing Work Valuation?..................................... 0 Mechanical Work Valuation? .................................. 0 Number of Stories................................................... 00 Is this an Online or O.T.C. application? .................. No Permit for Building Shell Only? .............................. No Plumbing to be Included? ........................................ No Comprehensive Plan Designation........................... City Center Core Zoning Designation ................................................. CC-C Total Valuation: 30,000.00 Me Fb&NM AMfttaftd VAM MOS PenUft h CONDITIONS: FIRE APPROVAL CONDITIONS: 1) Fire Inspection is not required. PERMIT EXPIRES Tuesday, 19 March, 2024 �t Permit Issued on Thursday, September 21, 2023 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of i Frt:F...: City of Federal Way. Owner or agent: Date: 1 AA THIS CARD IS TO REMAIN ON -SITE CITY OF "y Construction Inspection Record Federal Way INSPECTION REQUESTS: (253) 835-3050 PERMIT #: 23 103357 00 Address: 1751 S COMMONS Project: MERLONE GEIER PARTNERS FEDERAL WAY WA 98003-8548 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Q Footings/Setback (4110) 0 Re -steel (4215) Slab/Concrete Floor (4255) Approved to place concrete Approved to place concrete or grout Approved to place concrete By Date By Date By Date Q Underfloor Framing (4285) ❑ Floor Sheathing (4105) Q Fire/Draft Stops (4095) Approved to sheath floor Approved to install flooring Approved By Date By Date By Date Prior to scheduling a Framing inspection; ❑ Framing (4120) ❑ Insulation (4150) FElectrical, Plumbing & Mechanical Rough -in Approved to insulate Approved to install wallboard Fire/Draft Stop inspections must be signed - off and approved. IBC 109.3.4 By Date By Date 0 Gypsum Wallboard Nailing (4130) 30 Suspended Ceiling Grid (4265) El Final - S K F & R (4060) Approved to install mud & tape Approved to drop tile Approved By Date By Date By Date 12 Final - Planning 13 Final - Building (4050) Approved Approved By Date By Date ❑ Rough Electrical ❑ Final Electrical El Right of Way Approved Approved 1By Approved By Date By Date Date GEGTEST Inspection Report PROJECT: Federal Way Burlington Coat Factory ADDRESS: 17010 South Commons, Federal Way, WA PERMIT #: 23-103357-CO CLIENT: Merlone Geier Management, LLC CONTRACTOR: RCA 1888 2515276 Bellingham I Arlington Oak Harbor wv.nvgeotest-inc corn JOB #: 23-0030 REPORT #: I R001 DATE: 9/20/2023 PAGE #: 1 of 3 INSPECTOR: Tim Martin INSPECTION OF: Racking Support Fasteners. GeoTest was on site as requested to inspect the fasteners connecting the racking to the building's slab and the walls. The stand-alone racking at the stockroom, the racking at the sales floor's perimeter walls, the stockroom's interior walls and perimeter walls were inspected. The racking connections at the cold formed frame walls was found to conform with the project's drawings. The anchors used at the racking connections at the building's foundation slab were not the correct anchors (see image 4). The contractor rectified this by adding the correct anchors. Drawings referenced were A0.0, A1.5, R43, R57 and 171.0. Image #1: Perimeter racking at the sales floor was connected to a fire treated 2 x 4 furring stud at (3) elevations. COPIES: bgootee@merlonegeier com, dnordstrom@rca-inc corn, mbrown@rca-inc.com, mmitchell@rca-inc.com Reviewed by This report shall not be reproduced except in full, without the written approval of GeoTest Services, Inc. JOB #: REPORT #: PAGE #: 1.888.251.5276 Bellingham I Arlington I Oak Harbor www.geotest-inc.com 23-0030 IR001 2of3 n.iRMACos -Inspection Report PROJECT: Federal Way Burlington Coat Factory CLIENT: Merlone Geier Management, LLC CONTRACTOR: RCA Image #2: Fire treated 2 x 4 furring member with fasteners connecting it to the perimeter wall studs. GEOTEST Inspection Report PROJECT: Federal Way Burlington Coat Factory CLIENT: Merlone Geier Management, LLC CONTRACTOR: RCA Image #4: Regal MGF Co. stand alone and perimeter wall racking in the stockroom called for 1 /4" x 2-5/8" or 1 /4" x 3" anchors connecting the racking to the foundation slab. The anchors installed were only 1-1 /4" long. The contractor addressed this issue by removing them and installing the correct anchors at each post. 1,8ea251s276 Bellingham 1 Arlington I Oak Harbor JOB #: 23-00$0 REPORT #: IR001 PAGE #: 3 of 3