21-104366City of Federal Way
Community Development Dept
33325 8th Ave S
Federal Way, WA 98003
Ph: (253) 835-2607 Fax: (253) 835-2609
Building Single Family
Permit #:21-104366-00-SF
Inspection Request Line: (253) 835-3050
Project Name: MAGANA
Project Address: 34319 35TH AVE SW Parcel Number: 308900 0088
Project Description: BLUEBEAM - Construction of a new 2222 square foot 2-story single family residence with a
114 square foot covered entry and a 433 square foot attached garage. [eludes plumbing and
mechanical. *** 4 Bedrooms; $750000 Estimated Selling Price*** ,
Owner
Applicant
Contractor
Lender
DANIEL MAGANA
DANIEL MAGANA
OWNER IS CONTRACTOR
OWNER IS LENDER
2035 E 38TH ST
2035 E 38TH ST
TACOMA WA 98404
TACOMA WA 98404
Census Category: 101 - New Single Family House
Includes:
# 1
#2
#3
#4
Occupancy Class:
R-3
Construction Type:
Type V - B
Occupancy Load:
Floor Area (sq. ft.)
2,222.00
Additional Permit Information
New / Additional Sq. Feet - I st Floor .....................
980
New / Additional Sq. Feet - 2nd Floor....................
1242
New / Additional Sq. Feet - 3rd Floor .....................
0
Occupancy 41 - Area (Sq. Feet)..............................
2222
New / Additional Sq. Feet - Basement ....................
0
Basic Plan?,.............................:.:.:..::..:::...............
No
Occupancy #1 - Construction "type .........................
Type V - B
New / Additional Sq. Feet - Deck ...........................
0
New / Additional Sq. Feet - Garage ........................
433
Mechanical to be Included?.....................................
Yes
Plumbing Work Valuation?....................................I
3000
Mechanical Work Valuation?................:....I——.....,..
2000
Number of Stories ............................... :............. :.....
2
New / Additional Sq. Feet - Other...........................
114
Plumbing to be Included?_........ ........ . . .................
Yes
New / Additional Sq. Feet - Total...........................
2769
Will Certificate of Occupancy be Issued? ...............
Yes
Occupancy #1 - Use..:......:...:::.:.,;.........:.:.....,..
Residence (1 or 2
family)
Comprehensive Plan Designation ...........................
SF - High -Density
Zoning Designation .................................................
RS 7.2
Residential
Total Valuation: 298,160.33
Mechanical Fixtures
Ducting 1 Fans 5 Furnaces I
Plumbing Fixtures
Bathtubs 2 Dishwashers 1 Laundry Washer Outlets 1
Lavatories 4 Showers 1 Sinks 1
Water Closets 3 Water Heaters 1 Hose Bibbs 2
CONDITIONS:
Electric service & Electrical permits by TACOMA POWER.
PERMIT EXPIRES Sunday, 28 May, 2023
Permit Issued on Tuesday, November 29, 2022
I hereby certify that the above information is correct and that the construction on the above described property
and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of
Wash ing-tc d the City of Federal Way.
Owner or agent:
City of Federal Way
Certificate of occupancy
Date:
This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section
R110 of the International Residential Code is certifying that at the time of issuance, this structure was in
compliance with the various ordinances of the City regulating building construction or use. This certificate is valid
ONLY when endorsed by City staff.
Tenant Name: MAGANA
Address: 34319 35TH AVE SW
Includes: # 1 #2
Occupancy Class: R-3
Construction Type: Type V - B
Occupancy Load:
Floor Area (sq. ft.) 2,222.00
Owner Name: DANIEL MAGANA
Owner Address: 2035 E 38TH ST
TACOMA WA 98404
Building Official
Permit # 21-104366-00-SF
#3 #4
Date
The priority focus in the review and inspection made by the City prior to issuance of this Certificate was on those matters which
experience has shown most severely affect the health and safety of the general public. Although the City has made as complete
a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees
nor warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every
ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon
which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises.
As�
CITY OF
Federal llil'ay
- THIS CARD IS TO REMAIN ON -SITE .
Construction Inspection Record
INSPECTION REQUESTS: (253) 835-3050
PERMIT #: 21 104366 00 Address: 34319 35TH AVE SW
Project: DANIEL MAGANA FEDERAL WAY WA 98023
Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible
(read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if
you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card.
Q
SWM Precon Site Mtg (4400)
Efl
Site Assessment (Erosion) (4365)
Footings/Setback (4110)
Approved
To be done PRIOR to breaking ground
Approved to place concrete
By
Date
By
Date
By
AIJ Date 2L41-03—
® Foundation Wall (4115)
Drainage/Downspout (4040)
El Plumbing Groundwork (41190
Approved to place cone to
Approved to backfilI
Approved to cover V.iQs�
By n} Date 1
By Date 3 -7
By t! Date p
l
Slab/Concrete Floor (4255)
El
Underfloor Framing (4285)
Floor Sheathing (4105)
Approved to place concrete
Approved to sheath floor
Approved to install flooring
By
Date
By
Date .3 /0 113
By
J Q DateqAh 3
10 Shear Walls (4245)
El Roof Sheathing (4220)
Rough Plumbing (4230)
Approved to install siding
Approved to install rapl in
Approved
By t, o Date fi/�
By a Date
By �] Date i
13 Mechanical Rough -in (4165)
Approved
By Date
Interim Erosion Control (4370)
Approved
By Date
El Gas Piping (4125)
El
Fire/Draft Stops (4095)
Approved to release test
Approved
By Date
By
Date
Prior to scheduling a Framing inspection;
El
Framing (4120)
Electrical, Plumbing & Mechanical Rough -in
Approved to insulate
and Fire/Draft Stop inspections must be signed- offand approved. IBC 109.3.4
By
Date 51`a17j3
18
Insulation (4150)
19
Gypsum Wallboard Nailing (4130)
2a
Final Erosion Control (4375)
Approved to install wallboard
Approved to install mud tape
Approved
By
Date
By
/&
G Date
By
Date
Q Final - Mechanical (4065)
22 Final - Plumbing (4075)
23 Final - Building (4050)
Approved
By Date
Approved
By Date
Approved
By L)5► Date /0
�f�/zs -� — Wo3��err �,�na, eta r��.efie r k 5 � �0.vl PAC
Rough Electrical
❑
Final Electrical
Right of Way
Approved
Approved
Approved
By
Date
By
Date
By
Date
CITY OF . Building Division
33325 eighth Avenue South
Federal Wa Federal Way, Fax
98003-6325
y Phone 253-835-2607 Fax 253-35-609
CORRECTION NOTICE
ADDRESS: Sd:� I cl " �S�2 PERMIT#: ' JJ- 11'W%C
IF YOU HAVE QUESTIONS CALL (253) 835-
WHEN CORRECTIONS HAVE BEEN MADE, CALL'(253) -3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
c l 1,�L3
DATE
1
INSPECTOR
CEO NOT REMOVE THIS NOTICE
Page of
ciry bF
Federal Way
CORRECTI
' Building Division
33325 Eighth Avenue South
Federal Way, WA 98003-6325
Phone 253-835-2607 Fax 253-835-2609
N NOTICE
PERMIT#:�'
IF YOU HAVE QUESTIONS CALL (253) 835- Lc 71'T
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 83 -3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
DATE
SPECTOR
DO NOT REMOVE THIS NOTICE
Page of
CITY OF Building Division
33325 Eighth Avenue South
Federal
Wa Federal Way, 98003-6325
y Phone 253-835-2607 Faxx 253-835835-2609
CORRECTION NOTICE
ADDRESS: 3 PERMIT#: 2I- Oq t� 00
IF YOU HAVE QUESTIONS CALL Ke (253) 835- 2,
WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 83 -3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
E- 9 z _ ��
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of
CITY br Building Division
33325 Eighth Avenue South
Pederal Wa Federal Way, Fax
98003-6325
y Phone 253-835-2607 Fax 253 35-609
4:��Ak
CORRECTION NOTICE
ADDRESS: .;) ��01 kZ ��1.' PERMIT#: ����
IF YOU HAVE QUESTIONS CALL UU (253) 835- ' T
WHEN CORRECTIONS HAVE BEEN MADE, CALL (254 835-3050 FOR RE -INSPECTION. SEE BACK OF CARD
FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS.
11,5-ll 29
DATE INSPECTOR
DO NOT REMOVE THIS NOTICE
Page of