23-105061-SU- 1521049153 wtr swr- 11.15.2023CoA-2022.docx (Form Update 1/20/22) Page 1 of 4
WATER CERTIFICATE OF AVAILABILITY
Lakehaven Water & Sewer District – Development Engineering Section
31623 – 1st Ave S PO Box 4249 Federal Way, WA 98063-4249
Email: DE@Lakehaven.org Telephone: 253-945-1581 or 253-945-1580
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer Dist rict, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven’s or Other Purveyor’s system facilities.
Proposed Land Use: Building Permit-SFR () Building Permit-MFR () Building Permit-Other
Subdivision () Short Subdivision (3-5) Binding Site Plan
Boundary Line Adjustment Other (specify/describe)
Parcel Number(s): 1521049153 Site Address: 324XX – 39th Ave S LWSD GIS Grid: M-09
Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3,000-3,500 sf (ea.)
WATER SYSTEM INFORMATION
1. Water service can be provided by service connection to an existing 8” diameter water main that is approximately 55+/- feet
from the site.
2. If an additional fire hydrant is required/indicated, water service for the site will require an improvement to LWSD’s water
distribution system of:
a. 55+/- feet of 8” diameter water main to reach the site; and/or
b. The construction of a water distribution system on the site; and/or
c. A major portion of LWSD’s comprehensive water system plan would need to be implemented and/or
constructed; and/or
d. Other (describe): LWSD Developer Extension (DE) Agreement required.
3. a. The existing water system is in conformance with LWSD’s Comprehensive Water System Plan.
b. The existing water system is not in conformance with LWSD’s Comprehensive Water System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. a. The subject property is within the corporate limits of Lakehaven Water & Sewer District, or has been granted
Boundary Review Board approval for extension of water service outside of LWSD’s water service area.
b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Water service is subject to:
a. Payment of connection charges (to be determined by LWSD);
b. Proof or reservation of easement(s) as required by LWSD (if applicable under #2 above);
c. Other: LWSD Service Connection Applications required. If applicable, LWSD DE Agreement (#2 above) project
must be accepted by LWSD, prior to service connection activation. Reservation or proof of private easement(s) required for
water supply line(s).
Comments/special conditions: .
The nearest fire hydrant is approximately 145+/- feet from the Property (as marked on map on the back of this page).
System hydraulic model results (FF #317, copy attached), at no less than 20 psi, indicate that LWSD’s standard maximum allowable
liquid velocity of 10 ft/s is exceeded at a fire flow rate above 3,000 GPM. This flow figure depicts the theoretical performance of the
water distribution system under high demand conditions. Fire flow rates greater than this may be accommodated through water
distribution system improvements, contact LWSD for additional information.
578 Pressure Zone Est. Meter Elevation(s)-GIS: 415+/- Est. Pressure Range at Meter(s) (psi): 68-76
I hereby certify that the above water system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: Brian Asbury (e-signed) Date: 7/6/23
CoA-2022.docx (Form Update 1/20/22) Page 2 of 4
CoA-2022.docx (Form Update 1/20/22) Page 3 of 4
SEWER CERTIFICATE OF AVAILABILITY
Lakehaven Water & Sewer District – Development Engineering Section
31623 – 1st Ave S PO Box 4249 Federal Way, WA 98063-4249
Email: DE@Lakehaven.org Telephone: 253-945-1581 or 253-945-1580
This certificate is intended to provide the applicant, land use agencies &/or public health departments with
information necessary to evaluate development proposals. Lakehaven Water & Sewer District, at its sole
discretion, reserves the right to delay, or deny, sewer service based upon capacity &/or supply limitations
in Lakehaven’s or Other Purveyor’s system facilities.
Proposed Land Use: Building Permit-SFR () Building Permit-MFR () Building Permit-Other
Subdivision () Short Subdivision (3-5) Binding Site Plan
Boundary Line Adjustment Other (specify/describe)
Parcel Number(s): 1521049153 Site Address: 324XX – 39th Ave S LWSD GIS Grid: M-09
Ex. Bldg. Area to Remain: N/A sf New Bldg. Area Proposed: 3,000-3,500 sf (ea.)
SEWER SYSTEM INFORMATION
1. Sewer service can be provided by service connection to an existing ” diameter sewer main that is
approximately feet from the site and the sewer system has the capacity to serve the proposed land use.
2. Sewer service for the site will require an improvement to LWSD’s sanitary sewer system of:
a. 845+/- feet of 8” diameter sewer main to reach the site; and/or
b. The construction of a sanitary sewer collection system on the site (depending on the ultimate number & layout of
lots); and/or
c. A major portion of LWSD’s comprehensive wastewater system plan would need to be implemented and/or
constructed; and/or
d. Other (describe): LWSD Developer Extension (DE) Agreement required. Extend to far (SE) edge per LWSD policy.
3. a. The existing sewer system is in conformance with LWSD’s Comprehensive Wastewater System Plan.
b. The existing sewer system is not in conformance with LWSD’s Comprehensive Wastewater System Plan and an
Amendment to this Plan will be required. This may cause a delay in issuance of land use approvals or permits.
4. a. The proposed site land use is within the corporate limits of Lakehaven Water & Sewer District, or has been granted
Boundary Review Board approval for extension of sewer service outside of LWSD’s sewer service area.
b. Annexation or Boundary Review Board approval will be necessary to provide service.
5. Sewer service is subject to:
a. Payment of connection charges (to be determined by LWSD);
b. Proof or reservation of easement(s) as required by LWSD (if applicable under #2.b above);
c. Other: LWSD Service Connection Applications required. LWSD DE Agreement (#2 above) project must be accepted
by LWSD, prior to service connection activations. Reservation or proof of private easement(s) required for sewer
service lines.
Comments/special conditions: Some finish floor elevation(s) less than one-foot (1’) above nearest upstream manhole potentially
indicated, Backwater Check Valve potentially indicated, contact local building official for requirements &/or additional information.
I hereby certify that the above sewer system information is true. This certification shall be valid for one (1) year from the date of
signature.
Name: BRIAN ASBURY Title: DEVELOPMENT ENGINEERING SUPERVISOR
Signature: Brian Asbury (e-signed) Date: 7/6/23
CoA-2022.docx (Form Update 1/20/22) Page 4 of 4