Loading...
20-103268-PLAN-8.25.2020-V1PLAN THEFT PROTECTION This plan is copywrited and all rights are reserved including the right of reproduction in part or whole, except by A.R.BERGMAN DRAFTING & DESIGN LLC, this plan is not to be reproduced by anyone by any method including blueprinting, photocopying, photography, tracing, redrawing, or any other means. this plan may not be listed by anyone for repeat construction, on brochures, advertising, or any other purpose without written consent of A.R.BERGMAN DRAFTING & DESIGN LLC. This plan may not be knowingly furnished to others for such purposes. a. The right of building only one structure from the plan you have purchased is granted exclusively to the owner and their building contractor. Unlawful reproduction of this plan absolves A.R.BERGMAN DRAFTING & DESIGN LLC from all responsibility as to the accuracy of the drawings. And we may take suitable legal action against the copier under copyright laws. b. If any building is constructed from this plan other than the one for which the plan was purchased, we have the right according to copyright law to recover the value of the building less the cost of construction. CODES AND STANDARDS All workmanship is to be of a standard equal in all respects to good building practice. At the time of preparation, this plan was drawn in accordance with the current editors of the IRC 2015. It is the responsibility of the owner builder to insure that changes to the code are complied with and all amendments are incorporated in the construction of this plan. All work shall conform to local building codes and by laws that may take precedence. Prior to proceeding with construction, the builder must verify all information, dimensions, and specifications of this plan. Written dimensions always take precedence over scaled measurements. Any variances from the structural drawings or specifications or from conditions encountered at the job site shall be resolved by the owner builder and such solutions shall be their sole responsibility. The owner builder shall be responsible for the correct siting of the house on the property and for confirmation of all requirements for siting. A.R.BERGMAN DRAFTING & DESIGN LLC can accept no responsibility for plans not complying with the local side yards and setbacks of a specific piece of property. The owner builder to supply all mission missing dimensions on site plan, also elevations of lot, legal description, north direction, main streets and location of services. A.R.BERGMAN DRAFTING & DESIGN LLC shall not be responsible for conditions such as soil bearing capacity, depth of frost penetration, water table, buried structures, etc. A.R.BERGMAN DRAFTING & DESIGN LLC does not assume liability for any errors or omissions prior to commencement of construction. Any variances from the structural drawing and specifications are the sole responsibility of the owner builder. A.R.BERGMAN DRAFTING & DESIGN LLC shall not be responsible for any such variance made or advised by any official, builder, or other person and any such variance nullifies any responsibilities that A.R.BERGMAN DRAFTING & DESIGN LLC may have with respect to this plan or consequent construction. All requirements weather general or specific, shall be interpreted in conjunction with all other information appearing in the drawings and specifications. CONCRETE & FOUNDATIONS All concrete to have a minimum compressive strength of 3000 PSI at 28 days Concrete footings must be placed on undisturbed or compacted soil per IRC. Footings shown on these drawings have been designed for soil bearing capacity of 1500 PSF. Unless otherwise shown or noted, concrete coverage for reinforcing bars to face of bar shall be as follows: 1- concrete in contact with earth uniformed - 3 inches 2- Concrete in contact with earth formed - 3 inches 3- Wall, exterior face - 2 inches 4- Wall, interior face - 3/4 inches 5- Structural slabs 3/4 inches All reinforcements shall be positioned into concrete as per engineers details. Inserts shall be well secured in position prior to placing concrete. Refer to structural engineers notes for additional information. FRAMING Roof design load (Live and Dead) - 25 PSF Floor design load (Live and Dead) - 40 PSF Balcony deck design load (Live and Dead) - 60 PSF Stair (Live and Dead) - 200 psf Framing lumber shall be number two (2) Douglas Fir unless otherwise specified on plan. All beam and lintel sizes shown on the drawing are based on number two (2) Douglas Fir unless otherwise specified. Floor and roof sheathing to be laid continuous over two or more spans and face perpendicular to supports. Allow min. space 1 /16" between end joints and 1 /8" between edge joints for expiation and contraction of panels. Joists are to be doubled under parallel partitions. Joists shall be placed to accomodate heating and plumbing etc. All headers and trimmers to comply with IRC 2015. Refer to structural engineers notes for additional information. Owner builder to obtain certifigate from manufacturer of floor trusses, roof trusses, and glu-lam beams Wood in contact with concrete shall be pressure treated. New dimensions are from face of stud. ROOFING All roofing shall be applied according to the manufacturers recommendations. Trusses: Truss manufacturer shall furnish shop drawings showing calculations , all truss conditions connections and spacing. Design roof load as per truss manufacturers engineer. No truss shall be field modified without prior approval of building department. SHEET METAL Provide and install sheet metal ducts from all hoods and exhaust fans outside All required flashing to be 26 gauge galvanized metal unless otherwise specified. PLUMBING Provide and install plumbing and fixtures as indicated on plans according to local plumbing codes. ELECTRICAL/ HEATING Installation of entire heating system shall comply with manufacturers directions when applicable and conform with local building codes and regulations in all respects. Installation of all electrical items must comply with local electrical codes and regulations and with local electrical power supply regulations in all aspects. Outlet locations shown on plans comply with or exceed National Electrical Code requirements and are to be used as a guide only. Adjust according to owner and local authorities requirements. Approved heat smoke detectors to be installed as required per IRC 2015 GLASS Glass weights to comply with IRC 2015 If glass sliding patio doors are installed, they must be of tempered glass. Glass other than safety glass shall not be used for a shower or bathtub enclosure. All work shall comply with IRC 2015 Refer to drawing for specification CABINETS Field verify all cabinet dimensions prior to fabrication. Kitchen counter top should be 36" / 42" with 4" splash. Bath or counter top should be 30" with 4" splash and return. NAILING SCHEDULE (See IBC Table 2304.9.1) Joist to sill or girder 3-8d Bridging to joist, each end 2-8d Sill plate to joist or blocking 16d @ 16" ac Top laid stud 2.16d Doubled stud 16d @ 24" ac Doubled top plate 16d @ 16 ac Top plates, laps, and interx. 2.16d Ceiling joist to plate 3.8d Continuous header to stud 4-8d Ceiling joists, laps over partition 3-16d Built up corner studs 16d @ 24" ac SPECIFICATIONS Do not scale any drawings in this document All construction shall be in compliance with the IRC 2015 All dimensions shall take precedence over scale shown on plans, sections, and details Notes and details on drawings shall take precedence over general notes and typical structural details Material notes and specifications on the drawings shall take precedence over the specifications All edges of rescue windows from sleeping rooms have a minimum net opening of 5.7 sq. ft. and a minimum height of 24" minimum width shall be 20" egress and rescue from sleeping rooms shall have a sill height of not more than 44" MISCELLANEOUS Caulk over and around all exterior openings using non hardening caulk compound. Flash all changes of material on exterior walls. Flash over all exterior openings. All siding or stucco to be a minimum of 6" above finished grade. All balcony railings to be 36" in height. Maximum spacing between vertical members such that a 4" diameter sphere can not pass through Floor finishes, bathroom vanities, backsplash, and kitchen cabinets to meet specifications of owner builder. Coat closets should have at least one rod and shelf. Linen shelf shall have 5 adjustable shelves whenever possible. Ceramic and plastic tiles installed on walls around bathtubs or showers shall be applied over moisture resistant backing. All nails used in the exterior trims or sidings shall be galvanized or aluminum. Use cooler nails at 7" o.c. on all studs, plates, and blocking use 5d nails with 1/2" wallboard and 6d nails with 5/8" unless otherwise noted. Type and thickness of gypsum wall board as per drawings, all work to meet with manufacturers requirements. Ceiling insulation may be loose fill type or batt type, wall and floor insulation must be batt type. Walls and ceilings between residence and attached garage shall be insulated. Insulation requrrments may vary with heating system and local conditions. Please check with local authorities. All roof spaces shall be ventilated with soffit roof or gable vents or a combination of these equally distributed between the top or roof space and soffits. All ventilation of crawlspace and roof spaces to conform to IRC 2015 RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 0 A` x y O W I O Z O v E Im ~ Q 3 a N 1' Oa � y a ZWM M 3 H � Z LLI Z Ln W W H J -e W C> >L �� N IL O 0 J m Q W c Ua ` T o a2.4 a Q (n1ZaLna 3 Z W it o Ik Q m W co o W Q W m p m 0 caa�a � SCALE: DATE: 8/25/2020 SHEET #: 1 OF 6 SHEET: N100 I Q (n r a 0 N J O � 44 U) c La W r ch � W N L6 SITE PLAN 1 If = 1 0'-0" NORTH PARCEL#: 894500-0410 OWNER NAME: DEDEAUX STEVEN PROJECT ADDRESS: 2415 SW 331 ST ST FEDERAL WAY, WA 98023 PERMITTING JURISDICTION: CITY OF FEDERAL WAY LOT SIZE: 8,296 S.F FINISHED BUILDING AREA EXISTING: 1,040 S.F. PROPOSED FINISHED BUILDING AREA: 1725 S.F. SECT/TOWN/RANGE: SE-13-21-3 LEGAL DESCRIPTION: VILLAGE PARK DIV A LESS C & M RGTS PLat Block: Plat Lot: 41 EXISTING STRUCTURE — — PROPERTY LINE AREA OF WORK SETBACK EXISTING PATIO / 5' CONTOUR AREA OF WORK PAVED SURFACE PROJECT LOCATION ® O M1RPOR LAKE PDint Rd S-7mA s n Dash Po,nl 'ppsh Pomt Lak ola Middle Schad Slate Park a w 3Z., S!r TIrin 9 s.121, � L E D 0 N I A nz 2415 Southwest 331 st Streel �rx4 ut Mgrl Pavilion H Aoartm@rtt H6n1e5 T -WNS POINT SW 3361h5. xw c«n�,., a• Glen Park at wh Fred Meyer v 9 �i Campus � a atoPr or'`� m Eneote Apanment Homing //ma�yy U NPrepM Wry of .y P Qipxns Wn�/ RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT jot Z a W y 0 a� H 3 Wa 0 cill 0 y a Z ~I H Cc WZ N W v N L6 O v j m a W � c Ua ` T o a�a a a (a C4 2 3 Z W Cc o Cc Ili rrr� m W CO W oacLUCc0oc v C Q Q M Q H SCALE: DATE: 8/25/2020 SHEET #: 2 OF 6 SHEET: sl r Q � N O J Q La W r ch W N L16 is - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING PLAN 1 /4"= 1 '-0" NORTH DEMOLITION NOTES REMOVE EXISTING EXTERIOR SIDING FROM WALL REMOVE EXISTING FIXTURE/ APPLIANCE. SHUT OFF WATER & CAP WHERE APPLICABLE REMOVE CABINET �4 REMOVE DOOR AND SAVE FOR REUSE REMOVE WINDOW AND SAVE FOR REUSE Hard inter detectors requirted in all bedrooms DOOR SCHEDULE NUMBER QTY WIDTH HEIGHT DESCRIPTION COMMENTS D01 1 25 3/4 " 80 " POCKET -DOOR PO4 D04 2 30 " 80 " POCKET -DOOR PO4 D05 5 30 " 8011 HINGED -DOOR PO4 D06 1 15419 8011 4 DR. BIFOLD-LOUVERED D07 2 72 " 8011 4 DR. BIFOLD-LOUVERED D08 1 172 " 80 " EXT. SLIDER -GLASS PANEL REUSE EX. SLIDER WINDOW SCHEDULE NUMBER QTY WIDTH HEIGHT DESCRIPTION COMMENTS W01 1 32 " 42 " DOUBLE HUNG W02 1 32 " 42 " DOUBLE HUNG SAFETY GLASS W03 1 72 " 36 " LEFT SLIDING W04 2 72 " 3611 LEFT SLIDING IEGRESS W05 1 172 " 36 " JLEFTSI IDING IEGRESS, REUSE EXISTING WINDOW 2X 2X8 HDR. TYP. U.N.O. 11�'� `v r 0/"%1 � 1 /4 "= 1 '-0" NORTH WALL LEGEND EXISTING WALL TO REMAIN EXISTING WALL TO BE REMOVED SIDING TO MATCH, 1/2" GWB. FINISH NEW 2X4 INTERIOR STUD WALL 16" O.C., 1/2" GWB. BOTH SIDES RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT joO Z a a W 0 O 2 W 0 E LU � a 3 C4 ~ oar `� a Z W M cc ~O N. cc H ZZ d W Lu J W U) W 0 >L �� N L6 O 14 m R - T 0 a�a a a H N 3 Z W c c a 5 m W O W 2 a LL, C) C± caa °a � SCALE: DATE: 8/25/2020 SHEET #: 3 OF 6 SHEET: Al a r a C* C C N O J W W r 0 � W N IL 6' I AI(1Tr-:• ZV 2/A" Wr)l G 1 /Q" KAr-:CI-I RIRPI RI (1('6l M/GRV ()TWr-:D RAV I I nl(l `I - - - - - - 2116P -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7 52'-6" ROOF PL, 1 /4"= 1 '-0" NORTH FOUNDAI 1 /4"= 1 '-0" NORTH RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT jot Z a J z a oc 0 W O H 3 O 04 y a M ZW� J cc ~O N. cc H W Z+ N W _a Lu■- v hC N L6 O v m a W � c Ua ` T O a�a a a Z W cc O c a _ m W co W cc J cc O V C a a M a H SCALE: DATE: 8/25/2020 SHEET #: 4 OF 6 SHEET: Alml �Q �> r a � � N O J co N � O O W r � � W N SOUTH NEST SEGTION EAST NORTH RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT joO Z O - W N Z O Q W J W 0 W O H 3 O oa° y a occ M Z W ~O cc N. H ZZ d Ln W J W W V N L6 O v j m Q W � c Ua ` T O a�a Q aLo Z W c c Q O V J C Q Q M Q H SCALE: DATE: 8/25/2020 SHEET #: 5 OF 6 SHEET: A2 I=CIA �> r Q � � N O J Q co N � O O W r � � W N Qj ALTERNA 1 /4"= 1 '-0" NORTH RECEIVED Sep 03 2020 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT joO W a Z cc W J a 0 W O H 3 O oa° y a Z W � M cc ~O N. H cc ZZ d W Ln W J W V N L6 O v m a W c Ua ` T O IL a Q (a C4 3 Z W c c Q cc J cc O c V CQQMQ H SCALE: DATE: 8/25/2020 SHEET #: 6 OF 6 SHEET: A3 I=CIA �> r a � � N O J co N � O O W r � � W N