22-102874-permit set-6-23-22a t + +AJ Alp a 60� AN, r PROPOSE AREA SUIT #102 A 1 SITE PLAN y- N.T. (PROVIDED BY OWNER) Z PROJECT UENTIHICATION ZONING CODE CITY OF FEDERAL WAY MUNICIPAL CODE BUILDING CODE 2018 INTERNATIONAL BUILDING CODE W / STATE AMENDMENTS FIRE CODE 2018 INTERNATIONAL FIRE CODE ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE MECHANICAL CODE 2018 INTERNATIONAL MECHANICAL CODE PLUMBING CODE 2018 UNIFORM PLUMBING CODE ELECTRICAL CODE 2018 NATIONAL ELECTRICAL CODE ACCESSIBILITY CODE : 2018 INTERNATIONAL BUILDING CODE, ICC A117.1-2009 BUILDING ADDRESS 1805 S 316th St #102 Federal Way, WA 98003 PARCEL ID 092104-9304 ZONING CC—C NUMBER OF STORY 1 STORY — NO CHANGE BUILDING AREA BUILDING 1ST FLOOR — 9,738 SF — NO CHANGE TOTAL — 9,738 SF — NO CHANGE PROPOSE TITLE SEOUL CAFE PROPOSE AREA : 800 SF EXISTING OCCUPANCY GROUP : M (MASSAGE THERAPY) OCCUPANCY GROUP : A-2 (RESTAURANT) OCCUPANT LOAD CCULATIONS: TOTAL OF 28 OCCS DINING AREA : 392 SF / 15 = 26 OCC KITCHEN 173 SF/ 200 = 1 OCC STORAGE 131 SF/ 200 = 1 OCC RESTROOM, HALL WAY : (59+45) SF/ 0 = 0 OCC REQUIRED PLUMBING FIXTURE (TABLE 403.2-2) MEN, WOMEN : 1 WC, 1 LAV TYPE OF CONSTRUCTION : III—B, SPRINKLERED EGRESS CACULATIONS : OCCUPANCY A-2 NEEDS ONE MEANS OF EGRESS FOR LESS THAN 49 OCCUPANT LOSA EXITS PROVIDED : ONE DEAD END CORRIDOOR : 20 FEET EXIT SIGNS : REQUIRED AT ENTRY AND EXIT DOORS �# f LEGALDESCMPflON ELY 334.65 FT OF LOT 2 KCSP 281023R REC #8108050296 AS MEAS ALG S LN OF •* N 226 FT OF WLY 802 FT OF SW 1/4 OF SW 1/4 LESS RD AKA LOT B KC LLA 8810013 -: REC # 9005041240 4 SCOPE OF WORK TENANT IMPROVEMENT FOR SEOUL CAFE SCOPE OF WORK INCLUDES WALL FINISHES, MILL WORK, KITCHEN EQUIPMENT NO EXTERIOR WALL OR SITE MODIFICATIONS VCHTY VAP W V A d a Q Jasmine Mongolian Grill c rn 9Federal Way PAEC + on Mgolian BBQ "S _ QElephant Car Wash ® Palace Korean bar & grill® Reserve on OpenTable -'--- _ __ ___________ :E S 316th St S 316th St -_--__---= S 3161 QEl JnJMassageTherapy - min transit work m t Car Toys Palace SpaQ s n Ptr Car stereo store to tree Q + S 3161h PI Comfort Inn Feder I wn ss Way - Sean e Park 41 * (72 California Burrito a -star ho I I Modern, kid friendly activity space 1 Taco Shop © Mexican • S S 316th PI ns Centre II g mall Kum Kang San ®BBQ Grill Buffet Korean BBQ • SS I } Big 5 Sporting Goods I+ cken ® HomeGoodsV oepanmem Trader Joe's Sporting nggoods T.J. Maxx store ,en S score oe rtment store pa Bella Red Salon Total Vape & Smoke _ 0 Vaporize tore D S 318Ih PI Q to Center Plaza Q Grill ® I Grand P® eking Chinese aTac Village Shopping mall an $ I restaurant Sh ppn�nning inn Center sn,ei1 AREA SUIT 1102 GENERAL NOTES DO NOT SCALE THE DRAWING. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING OF ANY WORK, ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED, REPORT ANY DISCREPANCY TO THE ARCHITECT, ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM, FIRE SPRINKLER, HOOD, HOOD SUPPRESSION SYSTEM, WALK -IN -COOLER, AND SIGNAGE WORK ARE SEPERATE PERMIT. THE SUBCONTRACTOR SHALL SUPPLY THE ARCHITECT AND GENERAL CONTRACTOR DESIGN AND INSTALLATION DRAWINGS THE FIRST WEEK OF THE PROJECT AND SHALL UPDATE THEM AS CHANGES OCCUR. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND OTHER DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION. ALL QUESTIONS PERTAINING TO THE CONSTRUCTION AND MEANING OF DiR,4WING OR SPECIFICATIONS SHALL BE DECIDED UPON BY THE ARCHITECT OR IN THE CASE OF STRUCTURAL OR CIVIL DRAWING, THE ENGINEER. DOORS AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS OR DETAILS ARE TO BE LOCATED 4Y2` FROM THE ADJACENT WALL OR CENTERED BETWEEN WALLS AS GRAPHICALLY INDICATED ON THE DRAWINGS. The main water shut—off valve in the Premises shall remain in an accessible location at eye —level or below and before any distribution. (Existing on the rear wall.) A separate water flow meter in the Premises in an accessible location at eye —level or below after the main water shut—off and before any distribution. All demising walls between the Premises and adjacent spaces that Tenant constructs or modifies, if any, shall be full height to the underside of the roof deck, insulated and fire taped. Tenant shall be responsible for all odor control, sound transfer and related mitigation measures needed so as to not affect or be affected by adjacent tenants in the Center FIRE MONITORING SYSTEM: The Freeway X Building has a 24/7 fire monitoring system. Fire Protection, Inc. is the monitoring company at 1-800-429-0991. The fire monitor panel is located in the rear of Suite A (T—Mobile). EXCEPT IN THE CASE OF AN EMERGENCY, DO NOT TURN OFF THE CIRCUIT BREAKER TO THE HVAC UNITS) WITHOUT PRIOR NOTIFICATION TO STEVE OLSEN AND FIRE PROTECTION, INC. THIS WILL PUT THE FIRE MONITORING SYSTEM INTO AN ALERT MODE AND POLICE OR FIRE DEPARTMENTS MAY BE DISPATCHED LEGEND EXISTING TO REMAIN NEW WALLS PROJECT D RECTORY LANDLORD ADDRESS: WESTERN PALASIDE INC 3840 E MERCER WAY MERCER ISLAND, WA 998040 DRAMNIS INDEX A-1 SITE PLAN AND GENERAL INFORMATION A-2 FLOOR PLAN, EGRESS PLAN A-3 REFLECTED CEILING PLAN A-4 DETAILS P-1 PLUMBING PLAN OWNER ADDRESS : YEOH CORPORATION 1805 S 316TH ST #102 FEDERAL WAY, WA 98003 RECEIVED Jun 30 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT � N o W o 0 L� 00 U � � o Q o W � 00 0 W � LL_ FRONT EXIT DOORS SHOULD BE SHOWN WITH APPROVED SIGNS STATING THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED EXIST EXISTING TENANT SPACE Pupuseria y Taqueria La Princesa A2yFLOOR PLAN scare i/a'=i'-o" EXISTING TENANT SPACE Pupuseria y Taqueria La Princesa Ali EGRESS FLOOR PLAN SCALE: i/a'-i'-o" ixz 0 4 EXISTING TENANT SPACE LOTTE TRAVEL EXISTING TENANT SPACE LOTTE TRAVEL GENERAL FLOOR PLAN NOTES 1. GENERAL CONTRACTOR MUST VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTACT ARCHITECT IF ANY DISCREPANCIES ARE FOUND. ALL WORK SHALL BE IN COMPLIANCE WITH IBC 2009, NFPA, OSHA, AND ALL OTHER APPLICABLE GOVERNMENT AND REGULATORY AGENCIES, 2, VERIFY LOCATION AND PLACEMENT OF ELECTRICAL, PHONE, AND DATA LINES WITH OWNER BEFORE INSTALLATION OF ELECTRICAL BOXES AND DIRYWALL. 3_ FIRE EXTINGUISHERS AND MOUNTING BRACKETS TO BE UL LISTED. GG TO PROVIDE AND INSTALL, 4, MAINTAIN A MINIMUM OF 36" CLEAR, UNOBSTRUCTED EMERGENCY EXIT AISLE TOWARD DESIGNATED EXIT. 5, ALL GLASS IN HAZARDOUS LOCATIONS, AND WITHIN IS" OF THE FLOOR AND WITHIN 24' OF THE DOOR SHALL BE SAFETY GLASS, GENERAL CONTRACTOR TO VERIFY, G. ALL DOORWAY THRESHOLDS MUST COMPLY WITH CURRENT AND APPLICABLE CODE REQUIREMENTS. 1. ALL ROOMS OR AREAS HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE AT LEAST 2 EXITS TO EXTERIOR OR TO AN EXIT CORRIDOR (ONE=HOUR CONSTRUCTION) IBC TABLE 1015.1 EXITS SHALL HAVE A MINIMUM SEPARATION OF ONE HALF (Y3 IF SPRINKLERED) THE OVERALL MAXIMUM DIAGONAL OF THE BUILDING OR AREA SERVED, MEASURED IN A STRAIGHT LINE BETWEEN EXITS, IBC 1015.2.1. S. PROVIDE A FLOOR OR LANDING ON EACH SIDE OF DOORS NOT MORE THAN 1/4' LOWER THAN THE THRESHOLD OF THE DOORWAY (viz' IF BEVELED 1:2), LANDINGS SHALL HAVE WIDTH NOT LESS THAN THE WIDTH OF THE DOOR, DOORS IN FULLY OPENED POSITION SHALL NOT REDUCE A REQUIRED DIMENSION BY MORE THAN l INCHES. 9, ALL INTERIOR WALLS SHALL RECEIVE 20 GA. 3 1/2' MTL. STUD 6 16' O.C. W/ No' GWB ON ONE OR BOTH SIDES AS INDICATED ON FLOOR PLAN. USE 6' MTL. STUD a 16' Or -AS REQUIRED FOR PLUMBING WALLS OR AS INDICATED OTHERWISE NOTED ON THE PLANS, 10. MILLWORK TO BE BIDDER DESIGNED TO MEET REQUIREMENTS OF OWNER, ARCHITECT AND APPLICABLE CODES, FINISH SCHEDULE AREA FLOOR WALL CELLING BASE KITCHEN EXIST LATEX ENAMEL PAINT EXIST EXIST PORCELAIN TILE H-8' FRP BOARD DROP CEILING 4" VINYL COVE BASE EXIST EXIST EXIST EXIST HALL PORCELAIN TILE LATEX ENAMEL PAINT DROP CEILING 4" VINYL COVE BASE EQUIPMENT SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL 1 3 COMP SINK REGENCY 60S3151515GL 2 1 COMP SINK STEELTON 522CS11818RK 3 GREASE TRAP SCHIER GB1 4 HAND SINK REGENCY 600HS17 5 ICE MACHINE UNIFLOW KM-901 MAJ 6 GLASS WASHER EURODIB USA DSP3 7 ICE CREAM MACHINE STOELTING F231-1812-YG2ME 8 UNDERCOUNTER REFRIGERATOR DUKERS DUC60R 9 CAKE SHOWCASE HARMONY HM03936R 10 MOP SINK REGENCY 600SM16206 11 HOT WATER TANK RHEEM 50GAL ELECTRIC 12 13 FOOD MENU DRINKS ICE CREAM COFFEE, FRUIT TEAS, LEMONADE VANILLA, CHOCOLATE ICY BINGSU, FROZEN YOGURT RECEIVED Jun 30 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT O O L� � N O L�J O O L� 00 C� Q CD .. L0 Q C/-) O Q O LJJ 0 0 L� E)REFLECTED CEILING PLAN SCALE: 1/49=1'- SHEET SYMBOLS 2X4 FLUORESCENT WALL LIGHT FIXTURE NIGHT LIGHT FIXTURE C DOWNL IGHT WALL 2X4 FLUORESCENT WASHER FIXTURE LIGHT FIXTURE LIGHT TRACK 2X2 FLUORESCENT LIGHT FIXTURE PENDANT LIGHT FIXTURE IX4 FLUORESCENT O+ CEILING FIXTURE 0 LIGHT FIXTURE ® EXIT LIGHT FIXTURE STRIP FLUORESCENT CEILING DIFFUSER LIGHT FIXTURE STRIP FLUORESCENT LIGHT (� RETURN AIR GRILLE FIXTURE (HIDDEN IN COVE) J qO HEAT DETECTOR O DOWNLIGHT FIXTURE C SPRINKLER HEAD O ACCENT FIXTURE �P EMERGENCY 90 MINUTES BATTERY (E) EXISTING FIXTURE PACK LIGHT FIXTURE LIGHTING CONTROL ((R) RELOCATED EXISTING FIXTURE AUTOMATIC SHUT OFF CONTROL OS OCCUPANCY SENSOR DAYLIGHT ZONE CONTROL 0 FI RE ALARM EGRESS ILLUMINATION LIGHTING Z 7n1 R Caattla Fnorn\/ (nrla (mmnlinnpo Fnrmc fnr (nmmarrinI Ri iilrlinnc inrli irlinn R7 P1 Rd near I ctnriac and all P1 Ravicarl Ai in ?n?l rav q Project Title: Fill this line out on LTG -SUM Date 1/1/2018 Calculation Area NOTE 9 New Construction Addition - stand alone Spaces where < 20% of Spaces where >_ 20% of luminaires are replaced luminaires are replaced Addition + existing Spaces where the Use is changing (C505) For SDCI Use LPA Calculation Type Standard C406.3.1 Reduced LPA 10% C406.3.2 Reduced LPA To comply with C406.3.1 or C406.3.2, the Proposed LPD shall be 10% or 20% lower respectively than the Target LPA. Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting Wattage NOTE 1 Location (plan #, room #) Space Type Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Food preparation 173 0. 980 170 Dining area: family dining area 392 0.540 212 Corridor: all other 235 0.370 87 Art/Display/Exhibit/Ornamental Extra Lighting from LTG-INT-DISPLAY NOTE 8� Total Areal Retail Display 800 Allowance from LTG-INT-DISPLAY Allowed Watts 469 Proposed Lighting WattaLye NOTE 3 Location (plan #, room #) Fixture Description NOTE 4' 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Watts Proposed Kitchen can light 5 10 50 Dining can light 8 10 80 Restroom can light 1 10 10 Entries Exit light 1 10 10 Storage 2X4 Flourescent 1 10 10 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 160 Interior Lighting Power Allowance COMPLIES EMERGENCY D CHT NG DO MIN BATTERY OPERATED EMERGENCY _IGHTINC AND 1 ROOT CANDLE AT WALKING SURFACE LEVEL REFLECTED CEILING NOTES LIGHTING SYSTEM IS SHOWN SCHEMATICALLY AND IS TO BE BIDDER DESIGNED TO MEET REQUIREMENTS OF OWNER, MECHANICAL SYSTEM, AND APPLICABLE CODES AND REQUIREMENTS, MECHANICAL SYSTEM SHALL BE BIDDER DESIGN TO MEET REQUIREMENTS OF OWNER, APPLICABLE CODES AND REQUIREMENTS. VERIFY NUMBER AND LOCATION OF SUPPLY REGISTERS WITH OWNER BEFORE PROCEEDING WITH WORK, VERIFY NUMBER AND LOCATION OF RETURN REGISTERS WITH OWNER BEFORE PROCEEDING WITH WORK, PROVIDE SEISMIC BRACING FOR SUSPENDED CEILINGS PER DETAIL, LIGHTING NOTES LIGHT SWITCHES SHALL BE INSTALLED 48i' A.F.F.. MULTIPLE SWITCHES SHOULD BE GANGED TOGETHER UNLESS OTHERWISE SPECIFIED. CONTRACTOR TO VERIFY ALL SWITCH LOCATIONS WITH TENANT PRIOR TO INSTALLATION. NUMBER OF SWITCHES FOR OPEN AREA IS BIDDER DESIGN, CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING, STROBE LIGHTS, AUDIO VISUAL ALARMS, TO MEET ALL APPLICABLE CODES. PROVIDE FIRE DAMPER AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURE, WALLS, FLOORS, OR SURFACES, AND AS REQUIRED BY THE FIRE DEPARTMENT, IF APPLICABLE. ALL REQUIRED EXIT SIGN SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WITH ALL APPLICABLE CODES, CONTRACTOR SHALL PROVIDE SEISMIC BRACING AT ALL RELOCATED LIGHT FIXTURES. ELECTRICAL NOTES 1, EXTENSION OF EXISTING ELECTRICAL SYSTEM SHALL BE BIDDER DESIGN TO MEET THE REQUIREMENTS SHOWN, AND REQUIRED FOR LAWFUL AND PROPER INSTALLATION OF THE HIGHEST QUALITY. WORK SHALL CONFORM TO THE LATEST EDITION OF NATIONAL ELECTRIC CODE, STATE OF WASHINGTON ELECTRICAL CODE AND ALL OTHER CODES APPLICABLE TO THE WORK, DEVICES AND EQUIPMENT SHALL BE UNDERWRITER'S LABORATORIES, INC., LISTED AND LABELED, WHERE APPLICABLE, 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN CONTRACT INCLUDING APPROXIMATE LOCATION OF ALL NEW LIGHTING FIXTURES, OUTLETS, AND EQUIPMENT. 3, GUARANTEE EACH SYSTEM IN ITS ENTIRETY AND ALL PARTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 4. NEW SWITCH AND RECEPTACLES SHALL BE WHITE. 5. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15" ABOVE FLOOR UNLESS OTHERWISE NOTED OR REQUIRED. /o. ALL TELEPHONE AND COMPUTER WIRES SHALL BE PULLED BY TENANT CONTRACTOR UNLESS OTHERWISE NOTED. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL WIRES AND BOXES AT EACH LOCATION, 7. CONTRACTOR MAY USE EXISTING LIGHT FIXTURES IF IN PROPER WORKING CONDITION AND CODE COMPLIANT. AND G,4RRE����EQUIRCnTO 44INTAIN PLOOR I�C��ING, J. ELECTRICAL CONTRACTOR SHALL PROVIDE SEPERATE SWITCHING SYSTEM IN DAYLIGHT AREAS AS REQUIRED PER 2015 WASHINGTON STATE ENERGY CODE. RECEIVED Jun 30 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 12 JJ /V V J W W W U C� W Z L� W W CIL" U � N o w o 0 00 � � Q L0 Q CLn Q L_L O W 0 0 EXISTING CONCRETE DECK (POST -TENSION, VERIFY) 16 GA., METAL CLIP BY DIETRICH - E547 ATTACHED TO METAL DECK W/ (4) 08 x P4" SCREWS AND (3) 08 x I /v4" SCREW TO BRACE 2y" 20 GA METAL STUD BRACE, CUT FLANGE AND BEND WEB TO FORM A 2' MIN OV€RLAP, CONNECT TO TOP TRACK W/ (3) 08 METAL SCREWS OR USE CLIP ANGLE DIETRICH 5545, ALTERNATE BRACE S 9 40" O.C. MAX. 3 Y2", 20 GA TRACK W/ (2) 08 SCREWS PER STUD, I EACH SIDE SUSPENDED CEILING TILE. SEE REFLECTED CEILING PLAN. 5/8' GYPSUM BD, EACH SIDE 3 1/2', 20 GA TRACK W/ HILTI X-DNI (.145' DIA X 3/4" EMBED) POWDER ACTUATED FASTENERS PER I.C.B.O. REPORT NO. 2388 5PACED MAX. 24' O.C. AND 6" MAX. FROM ENDS EXISTING FINISHED FLOOR PARTITION WALL SEISMIC BRACING NOT TO SCALE ACCESSIBILITY NOTES L ALL WOIRKM,4N5HIP AND MATERIALS SHALL BE IN ACCORANCE WITH ICC/ANSI 4111.1, LATEST EDITION. 2_ MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, 3 ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE DOOR AT 90° TO THE CLOSER POSITION, MAXIMUM HEIGHT OF THRESHOLD TO BE i'/2" MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4" WITH A MAX BEVEL OF 45°, 5EI5MIC STRAP AT FROM TOP 4 BOTTOM PER LATEST UPC CODE 50 GAL. HOT WATER TANK 24"x24" DRAIN PAN SECTION WATER TANK NOT TO SCALE 5E15MIC P05T 5CHEDULE I. UP TO -7'-0" VERTICAL HEIGHT USE 1- 5 5/8" 25 OA METAL STUD AT 12'-0" OG MAX EACH WAY 2. 1'-0" TO 10'-0" VERTICAL HEIGHT USE 2- 1 5/8" 25 GA METAL STUDS AT 12'-0" OC FASTENED BACK TO BACK WITH 5CREW5 12" O.G. AT EACH SIDE OF MAIN RUNNER TYP 5. 10'-0" TO 15'-0" VERTICAL HEIGHT USE 2- 2 1/2" 25 GA METAL STUDS, FASTEN SAME AS NOTE #2 4. ALTERNATE: EMT CONDUIT - 1/2" EMT CONDUIT - UP TO 6-0" - 5/4" EMT CONDUIT - UP TO &'-6" - I" EMT CONDUIT - UP TO 10'-0" 450 RUNNER 5GREWS AFTER TILE PANEL 15 INSTALLED LATERAL 5UPPORT BRACE AT 12'-0" OG EACH WAY 12 GA. VERT. HANGER WIRE 4'-0" O.G. BOTH WAYS LATERAL FORGE BRAGINO 4 EA. 12 OA. WIRE 450 SECURED TO MAIN RUNNER WITHIN 2" OF GROSS TEE INTERSECTION $ SPLAYED cf0° FROM EA. OTHER @ I2'-0" O.G. IN BOTH DIRECTIONS W/ FIRST POINT WITHIN 4'-0" FROM EA. WALL. MAIN RUNNER TEE SEISMIC SUPPORT FOR SUSPENDED CEILING NO SCALE NOTFS: I. INSTALL SYSTEM IN ACCORDANCE W/ IBC SEC, 8051, ASCE-1, A5TM C 655 $ 656. 2. SUPPLY COMPRESSION STRUTS ADJACENT TO LATERAL BRACING POINTS 5. SUPPLY ADDITIONAL 12 6A, WIRES FOR LIGHT FIXTURES INDEPENDENT OF GRID SUSPENSION SYSTEM. 4. ONLY HEAVY DUTY ORID SYSTEM 15 ALLOWED 5. SUPPLY STABILIZER BARS TO PREVENT THE SPREAD OF MAIN BEAMS AND/ OR GROSS TEES AT THE PERIMETER WALL5. 6. SPRINKLER HEAD PENETRATION SHALL HAVE A 2" OVERSIZE RINO, SLEEVE OR ADAPTER. �A. VERT. WIRE (TYP.) .EADER BAR JRNS MIN. (TYP) N RUNNER OR �55 TEE )VIDE 5/4" SCE @ OFF. -L �U5TICAL CEILING TILE MALL MOLD 'AGH MEMBERS PERIMETER 8 TWO ADJ. HALLS ONLY. RECEIVED Jun 30 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT � N O w o 0 w 00 w +J Q 0 � � w 0 Q w L rr" O w • � 0 o w w EXIST C.0 XISTING ENANT PACE Pupuseria y Taqueria La Princesa LPD1PLUNGING PLAN SCALE: 1/4'=1-0" 1 1/2 JI)o VENT XISTING ENANT PACE LOTTE TRAVEL EXISTING 4" SEWER F 0 HYDOROMECHANICAL GREASE INTERCEPTOR (HGI) CALCULATIONS DFU CALCULATION : DFUs are calculated using Uniform WAC 51-56-1000 Chapter 10—Traps and interceptors. 9 DFU s NEED 25 GPM < 10 DFU s GREASE INTERCEPTOR SIZE TO INSTALL : 25 GPM DFU CACULATION FIXTURE QTY DFU# TOTAL DI 3 COMP SINK / FLOOR SINK 1 9 9 1 COMP PREP SINK/ FLOOR SINK(VEG) 1 — NOT CONNECTED ICE MACHINE / FLOOR SINK 1 — NOT CONNECTED HAND SINK 1 - NOT CONNECTED MOP SINK 1 NOT CONNECTED TOTAL VENT 1 1/ 1 1/2° 01 1/2" �VENT2 VENT (VENT � C.0 ?5 GPM 2 CREASE TRAP SEWER LINE DIAGRAM SCALE: NONE monk ICE MAKER 2„ (F�SISS WASHER EXISTING 4" SEWER 3/4" PEX PIPE EXISTING IHOT CTRIC H.W. 1/2 SPE I FICATIONS Haa@'t 1 4" FPT inlet/Outlet with 2' and 3" plain end fittings. 2. Unit weight - 39 lbs. (wet weight 123 lbs.) & Capacities - Liquid:10 gal. @20 GPM- Grease: 70 lbs. (9.6 gal.) @25 GPM- Grease: 64.9 Ibs. (8.9 gal) Solids:1.3 gal. 4a Bui t-in flow control. 9. For gravity drainage applications only. 0. Do not use for pressure applications. To Cover placement allows ffu00 access to tank for proper maintenance. £3a Vent not required unless per Docal code. fla Engineered inlet and outlet diffusers are removable to inspect/clean piping. W.Integral air relief / anti -siphon. [Eng8 �3o bn (Pmmo Schier Great Basin- grease interceptor model ## GB1 shall be lifetime guaranteed and made in USA of seamless, rotationally -molded polyethylene. Interceptor shall be furnished for above or below grade installation. Interceptor shall be certified to ASME A112.14.3 (type C) and CSA B481.1, with field cut riser system, bui t-in flow control and three o0et options. interceptor flow rate shall be 20 or 25 GPM. Interceptor grease capacity shall be 70 lbs. @ 20 GPM or 64.9 ft. @ 25 GPM. Cover shall provide water/gas-tight seal and have minimum 450 lbs. load capacity. ed P�I,101 rman�e Great Basin*"° hydromechanical grease Interceptors are third party performance -tested and listed by DAPM® to ASME A112.14.3 and CSA B481.1 grease interceptor standards and greatly exceed requirements for grease separation and storage. They are compliant to the Uniform Plumbing Code, the National Standard Plumbing Code, the National Plumbing Code of Canada, and the international Plumbing Code. SCHIER �� LIFETIME GUARANTEED ���. GREASE INTERCEPTORS 27' ®aut0®t'A' paw (Opt➢ona0) O 00 44O Outlet "S' (Standard) outlet foot O°O ® D 00 must face this direction in a00 o°O°O°O ao oe°e°e configurations ®utiet'c' (optional) (j of 4• EPT See Note ##10 inlnqloStatic t&tlt � o 21-1/2' C 15-1/4'° invert water line Engineered Inlet and outlet diffuser OOUTLC T ENDD VI W 23"� [n�0o DD CaL HU BIERa Got DEG 3[[?4[ a0[�o 20/25 GPM Polyethylene Grease Intercepter PART *: 4060-001-04 DWG BY: B. Karr®r DATE: 411012010 1 REV: ECO: 030000Mn7@@dwd4Rwd I EdvmvdvAs, K8 00111 I7@0:I .*@W➢@oprodU@k.@@M PEX PIPE HOT 3/4" COLD 3/4 PEX PIPE COLD 1/2 11 PEX PIPE MOP HOT ' 1/2 if HT 1 2" '1 /2" COLD COLD 1 /2" 1/2 1) 1COMP 3COMP OWATER LINE DIAGRAM 0 C@P"g a4 2010 B@hh@w, Al VR➢ M@ f oon'@d PE PIPE HT 1 2" COLD 1/2 11 H.S [?ado 4 04 4 COLD 1/2 P1 ICE MAKER RECEIVED Jun 30 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Q Q � Z W O O I� I n C� LLJ �-�r� W Cal O LLJ O (::D L� 00 Q 0--) U Q O c- � -4-- (0 < o Q Ln O W 0 o L� P-1