Loading...
22-102989-PERMIT SET-7-12-22INTERIOR ALTERATION 1122 S 322ND PL FEDERAL WAY. WA. 98003 SCOPE OF WORK: INTERIOR ALTERATION INVOLVES ALTERATION OF EXISTING CLASSROOMS AND SUPPORT SPACES. MINOR MODIFICATION TO EXISTING HVAC, NEW LIGHTING, PLUMBING AND POWER. SITE PLAN 1122 S 322nd PI bx'o 5 C �l KEYEDNOTES: INDICATED BYO SYMBOL 1. EXISTING T-0"W (MIN 32" CLEAR EXIT WIDTH) EXIT DOOR. DOOR ALLOWS MAXIMUM 160 OCCUPANT EGRESS BASED ON 0.2" PER OCCUPANT. 2. EXISTING 6'-0"W (MIN 68" CLEAR EXIT WIDTH) EXIT DOOR. DOOR ALLOWS MAXIMUM 360 OCCUPANT EGRESS BASED ON 0.2" PER OCCUPANT. GENERAL NOTE: GENERAL CONTRACTOR SHALL INSTALL ADDITIONAL FIRE EXTINGUISHERS IF DETERMINED NECESSARY BY THE FIRE MARSHAL. INDEX OF DRAWINGS A00 COVER SHEET I CODE INFORMATION I KEY/LIFE SAFETY PLAN A01 SITE PLAN & DETAILS A10 DEMOLITION I CONSTRUCTION PLAN A20 CEILING I FLOOR FINISH PLAN I FINISH & MATERIAL LIST A30 MILLWORK & RESTROOM DETAILS MP0.0 MECHANICAL & PLUMBING GENERAL NOTES, SCHEDULES & DETAILS MP1.0 MECHANICAL & PLUMBING DEMOLITION PLAN MP2.0 MECHANICAL & PLUMBING NEW WORK FLOOR PLAN E0.0 ELECTRICAL GENERAL NOTES & DETAILS E1.0 ELECTRICAL DEMOLITION FLOOR PLAN E2.0 ELECTRICAL NEW WORK FLOOR PLAN CONTACT INFORMATION EGRESS NOTE: NO CHANGE IN EXISTING EGRESS CAPACITY AND/OR REQUIREMENTS HWAI YANG ARCHITECTS HWAI YANG USE GROUP E - EDUCATIONAL (DAYCARE) SQUARE FEET: 10314 DONOHO PLACE ST. LOUIS . MO. 63131 MEANS OF EGRESS - CHAPTER 10: 314.853.8008 1. MAXIMUM OCCUPANT LOAD - TABLE 1004.5 TOTAL OCCUPANTS = 133 (SEE MATRIX BELOW) hwai@hwaiyangarchitects.com 2. MEANS OF EGRESS - SECTION 1006.2.2.4 DAY CARE FACILITIES, ROOMS OR SPACES WHERE CARE IS PROVIDED FOR MORE THAN GUIDEPOST MONTESSORI 10 CHILDREN THAT ARE 2 2" YEARS OF AGE OR LESS, SHALL HAVE ACCESS TO NOT LESS THAN TWO EXITS OR EXIT ACCESS DOORWAYS. JOHN STELLER 3. EGRESS WIDTH PER PERSON - SECTION 1005.3.2 EXCEPTION 1 10 ORCHARD RD, STE 200 OCCUPANT LOAD 133 X 0.2 PER OCCUPANT = 26.6" LAKE FOREST. CA. 92610 MINIMUM WIDTH PROVIDED: 32" 214.704.1146 # OF EXITS REQUIRED: 2 # OF EXITS PROVIDED: 6 jsteller@tohigherground.com ALLOWED PROPOSED EXIT ACCESS TRAVEL DISTANCE - TABLE 1017.2 250'-0" W/SPRINKLERS 140'-4" OK CODEINFORMATION COMMON PATH OF TRAVEL DISTANCE 75'-0" 53'-8" OK GC SHALL VERIFY EACH SIGN IS FUNCTIONING PROPERLY OR REPLACE WITH NEW. NEW EXIT APPLICABLE CODES & REGULATIONS SIGNS SHALL BE ADDED TO NEW CLASSROOM EXIT DOORS LEADING TO EXTERIOR. INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION, INCLUDING APPENDICES E AND J WASHINGTON STATE AMENDMENTS, WAC 51-50 AND RCW 19.27 & 70.92 ACCESSIBILITY CODE ICC/ANSI A117.1-2009 INTERNATIONAL RESIDENTIAL CODE (IRC), 2018 EDITION, INCLUDING APPENDICES H & J AND EXCLUDING CHAPTERS 11 AND 25 THROUGH 43 WASHINGTON STATE AMENDMENTS, WAC 51-11R, 51-56 AND 296-46B INTERNATIONAL MECHANICAL CODE (IMC), 2018 EDITION WASHINGTON STATE AMENDMENTS, WAC 51-52 AND RCW 19.27 INTERNATIONAL FIRE CODE (IFC), 2018 EDITION, INCLUDING APPENDICES B, C, E, F, AND I OCCUPANT LOAD CALCULATION FOR USE GROUP DESIGNATION: WASHINGTON STATE AMENDMENTS, WAC 51-54A AND RCW 19.27 INTERNATIONAL EXISTING BUILDING CODE (IEBC, 2018 EDITION INTERNATIONAL FUEL & GAS CODE (IFGC), 2018 EDITION GROUP AGE RANGE # OF CHILDREN INTERNATIONAL PROPERTY MAINTENANCE CODE (IPMC), 2018 EDITION NIDO 6 WKS - 18 MOS 24 INTERNATIONAL ENERGY CONSERVATION CODE (IECC), 2018 EDITION WASHINGTON STATE AMENDMENTS, WAC 51-11R & 51-11C AND RCW 19.27 TODDLERS 18 - 36 MONTHS 29 WASHINGTON STATE ENERGY CODE (WSEC), 2018 EDITION 2 2 YRS & UNDER - 3 18 - 30 MONTHS 20 NATIONAL ELECTRICAL CODE (NEC), 2020 EDITION WASHINGTON STATE AMENDMENTS, WAC 296-43, 296-45 & 296-46B AND RCW 19.28 30 - 36 MONTHS 9 UNIFORM PLUMBING CODE (UPC), 2018 EDITION, EXCLUDING CHAPTERS 12 AND 15 WASHINGTON STATE AMENDMENTS, WAC 51-56 AND RCW 19.27 CHILDREN'S HOUSE 3 - 6 YEARS 70 FEDERAL WAY REVISED CODE CODE CLASSIFICATION TOTAL CHILDREN UNDER 2 YEARS OF AGE 44 A. OCCUPANCY GROUP: E - EDUCATION - DAYCARE 2 B. CONSTRUCTION CLASSIFICATION: TYPE II B TOTAL CHILDREN OVER 2 1 YEARS OF AGE 79 C. BUILDING IS NOT SPRINKLERED; MODIFICATIONS WILL BE ENGINEERED AND SUBMITTED BY TOTAL CHILDREN 123 FIRE SPRINKLER CONTRACTOR FOR REVIEW AND PERMIT. D. EXISTING FIRE ALARM WILL BE UPGRADED IF REQUIRED TO COMPLY WITH CURRENT CODE. PER SECTION 308.5.1 A CHILD DAY CARE FACILITY THAT PROVIDES CARE BUILDING SQUARE FOOTAGE EXISTING AREA 6,000 SF FOR MORE THAN FIVE BUT NOT MORE THAN 100 CHILDREN 21 YEARS OR PROPOSED ALTERATION SPACE 6,000 SF LESS OF AGE, WHERE THE ROOMS IN WHICH THE CHILDREN ARE CARED FOR ARE LOCATED ON A LEVEL OF EXIT DISCHARGE SERVING SUCH ROOMS AND EACH OF THESE CHILD CARE ROOMS HAS AN EXIT DOOR DIRECTLY TO THE EXTERIOR, SHALL BE CLASSIFIED AS GROUP E. LIFE SAFETY PLAN LEGEND 2 A:20-B:C TYPE PORTABLE FIRE EXTINGUISHER IN A WHITE MTL BOX PARTIALLY RECESSED. (ROUND EDGES)(MTL DOOR NO GLASS) ® EXIT SIGN COMBINATION EMERGENCY EXIT SIGN & LIGHT PER 1010.1.5-6 MAINTAIN FLOOR/LANDING @ SAME ELEVATIONS ON BOTH SIDES OF DOOR FOR A DISTANCE OF NOT LESS THAN THE WIDTH OF THE WIDEST DOOR LEAF AT EACH DOOR & A MINIMUM LENGTH OF NOT LESS THAN 44" GENERAL NOTE: GENERAL CONTRACTOR SHALL INSTALL ADDITIONAL FIRE EXTINGUISHERS IF DETERMINED NECESSARY BY THE FIRE MARSHAL. PROVIDE EGRESS LIGHNTING PER IBC 1008.2 AND 1008.3.2 EGRESS PLAN SCALE: 1/8" = 1'-0" v IBC 52:8, 22-102989 1016.2 egress shall not 108 pass E CLASSROOM 3 through AG GROUP: TODDLERS OO� kitchen, OCCUPANCY:291�2 SF 173 SF/CHILD ENROLLMENT: STAFFF ROOM store rmS,Or E: 16-36 MONTHS sl 'lar rms 26'-8" OK > 2 MAX DIAGONAL OF ROOM �� rr o�Q COT Ste. 106 ^ti CLASSROOM 2 AGE GROUP: CHILDREN'S HOUSE 105 1 AREA: 1284 SF 149 SF/CHILD OCCUPANCY: 37 1 ENROLLMENT: 26 CORRIDOR AGE: 3-6 MONTHS exit �' 10 Ou WID sign 3 EX TO WH / 101B 108A O 111 PTA EX T ET V DW O� �opM 1 y 103 102 101A ON o EX PANTRY STAFF BREAK EX C �jq 104A EX EX OILETREF 101 exit EX RECEPTION sign 44'-1%" OK > i MAX DIAGONAL OF ROOM 1os O EX CLASSROOM 4 ti 104 U AGE GROUP: NIDO �\ AREA: 828 SF 173 SF/CHILD EX CLASSROOM 1 OCCUPANCY: 29 1 ENROLLMENT: 8 AGE GROUP: CHILDREN'S HOUSE AGE: 6 WEEKS -16 MONTHS AREA: 1122 SF 143 SF/CHILD OCCUPANCY: 32 1 ENROLLMENT: 26 AGE: 3-6 MONTHS EX LE F,10 EX OFFICE S3; OCCUPANT LOAD AND EXIT WIDTH SPACE AREA 100 EX VESTIBULE 51 101 EX RECEPTION 421 102 STAFF BREAK 84 103 EX PANTRY 174 104 EX CLASSROOM 1 CH 1,122 106 EX CLASSROOM 2 CH 1,284 107 STAFF PREP 191 108 EX CLASSROOM 3 TODDLER 1,012 109 EX CLASSROOM 4 NIDO 828 110 EX OFFICE 124 1 AREA PER CALCULATED EGRESS WIDTH PER ACTUAL WIDTH SHOWN REQUIRED EXIT WIDTH OCCUPANT OCCUPANT LOAD OCCUPANT (SEC 1005) ON PLANS STAIR LEVEL STAIR LEVEL STAIR LEVEL 150 1 NA 0.15 NA 0.13 32" MIN NA 1 X 32" 150 3 NA 0.15 NA 0.50 32" MIN NA 1 X 32" 150 1 NA 0.15 NA 0.16 32" MIN NA 1 X 32" 150 2 NA 0.15 NA 0.25 32" MIN NA 1 X 32" 35 33 NA 0.15 NA 4.88 32" MIN NA 2 X 32" 35 37 NA 0.15 NA 5.58 32" MIN NA 2 X 32" 150 2 NA 0.15 NA 0.27 32" MIN NA 2 X 32" 35 29 NA 0.15 NA 4.41 32" MIN NA 2 X 32" 35 24 NA 0.15 NA 3.62 32" MIN NA 2 X 32" 150 1 NA 0.15 NA 0.20 32" MIN NA 2 X 32" TOTAL 133 0.15 19.99 72" MIN 9611+ NUMBER AND ARRANGEMENT OF EXITS SPACE USE GROUP/AGES MINIMUM NUMBER OF EXITS TRAVEL DISTANCE ARRANGEMENT MEANS OF EGRESS ACTUAL TRAVEL SHOWN ON ALLOWABLE TRAVEL REQUIRED DISTANCE ACTUAL DISTANCE REQUIRED DISTANCE SHOWN ON PLANS DISTANCE BETWEEN EXIT DOORS SHOWN ON PLANS PLANS 104 EX CLASSROOM 1 CH E/3-6 YRS 1 2 250'-0" < 75'-0" 26'-8" 44'-1" 106 EX CLASSROOM 2 CH E/3-6 YRS 1 2 250'-0" < 75'-0" 25'-11" 44'-1" 108 EX CLASSROOM 3 TODDLER E/18-36 MOS 2 2 250'-0" < 75'-0" 26'-4" 26'-8" 109 EX CLASSROOM 4 NIDO E/0-18 MOS 2 2 250'-0" < 75'-0" 28'-8" 27'-3" HWAIYANG A R C H I T E C T S 10314 DONOHO PLACE ST. LOUIS I MISSOURI 1 63131 hwai@hwaiyangarchitects.com 10835I REGISTERED J�'AI L ANG OF WASHINGTON 0 O C/) O U) Q 86 CZ CZ N E M Cz QN r CZ T -- 7C3 RECEIVED 7/18/22 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT z w CD o N � N H � o 0 U_j Cn O CV z `1' wN CD � N z o o V Q Y o CD LPL PROJECT #: 22-917 FILE NAME: 22-917_CD DRAWN BY: HY CHECKED BY: HY SHEET #: AOO COVER SHEET I CODE INFORMATION KEY/DEMOLITION PLAN O I PARKING CALCULATION 19.195.090 Day care facilities, commercial 1 for each 300 sq. ft. of gross floor area Age Floor area GSF Spaces Reqd SITE LEGEND Required Off Street Provided we 20 19 + 1 HC OK SITE PLAN SCALE: 1" = 20'-0" S80 048' 13 " E 43,1 . 16 ' (C) /134 . 17 ' (P) (P) U LL GV (2) Ack-1 VC 'a —F D C SBB'48' 13"E 217.09' (C) 217.09' (P) 12.8 I 1 � LU z KETBALL a SH 55.4' ED BASHOpP } TETHERBALL U POLE 1 CHILQRENS HOUSE PLAYGROUND 5,850 SOFT REQUIRED Ln 13.791 SOFT SHOVL11V O _ � x_ CIL TOTAL GROSS BUILDING SOFT: 00 6.285SOFT Lli Q V U wo r; GAT' 2 1 • 4 ' �IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII SIGN ICBCJ8 � PLANTER°°�� TP VIP� Ali VC EC GATE I TODDLER PLAYGROUND 1,150 SOFT REQUIRED 3 FT SHOWN 7//1 z O I G -1 E !-.1. W V 64 . .. t n b' gC' ` EC S o • roJ �, P LE SSIGN 5` CYCLONE FFNCE O3 PLAY AREA 100.7' 5 ' CYCLONE ;- L-INEF O II } PLAY AREA LAY SET NVELOPE 'al z w z CD _J U U ' S CB LU r__ . v 1 1B 17 10 1.5 . I4 EXISTING PERIMETERIINTERMEDIATE FENCE TO REMAIN W EC TEMPORARY FENCING, REMOVE ONCE NIDO IS PHASED OUT w ILL TEMPORARY NID6 PLAYGROUND 6Ud SQFT REQUIRED W 646 SOFT SHOWN 0 J 3 4 5 6 7 S• 1i� 1.1 12 13 U CD X 9�fi d FH I 172.09' (C) 172.09' (P) LS H 45.00' (RADIUS) M .� W/ PUNCH, �SfiMH S88 48 13"E 217.09'� BDILDING BUILDING FACE IS 1.6' SOUTH OF LINE WV® VC (O A —a — — — LLL CV 2 d �w �o z 0 g z _ 0 M O 5 X 5 POSTS = 97" 8 6-0" PLAYGROUND VINYL/CEDAR FENCE SCALE: 3/8" = V-0" 1. EXIT DISCHARGE. 2. DESIGNATED EVACUATION ASSEMBLY AREA. 2 2 —10 2 9 8 9 3. FIRE DEPARTMENT AND EMERGENCY VEHICLE ACCESS. 4. PATH TO PUBLIC WAY 0 5. CHILDREN DROP OFF/PICK UP AREA KEYEDNOTES: INDICATED BYO SYMBOL ALL SITE COMPONENTS ARE EXISTING UNLESS NOTED OTHERWISE. 1. EXISTING W SIDEWALK. 2. TODDLERS' PLAYGROUND EQUIPMENT & CONCRETE TRIKE LOOP (GC TO PROVIDE AND INSTALL). 3. CHILDRENS HOUSE PLAYGROUND EQUIPMENT & CONCRETE TRIKE LOOP (GC TO PROVIDE AND INSTALL). 4. 4'-0"H FENCE. 5. 6-0"H PRIVACY FENCE WITH ACCESS GATES WHERE SHOWN. LOCK ON GATE S SHALL NOT REQUIRE ANY SPECIAL KNOWLEDGE TO OPEN DURING EGRESS EVENTS. 6. CLEAN EXISTING CONCRETE PARKING SURFACE WITH DEGREASER AND HIGH PRESSURE WASH. RE -STRIPE ENTIRE PARKING SURFACE. 4 4'-0" PLAYGROUND VINYL/CEDAR FENCE SCALE: 3/8" = V-0" HWAIYANG A R C H I T E C T S 10314 DONOHO PLACE ST. LOUIS I MISSOURI 1 63131 hwai@hwaiyangarchitects.com 10835 REGISTERED ITECT Lq_ �09=04111 . O co CD Cn Cn -a86 F c� co Cn cn M u QCV ^,70 T (� T .� 70 RECEIVED 7/18/22 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Z zUj CDo Cn cn a N U = W W � d 6 N Z zC-r CV LU N CD Z o o V a Y OC o� Q O o � � PROJECT #: 22-917 FILE NAME: 22-917 CD DRAWN BY: HY CHECKED BY: HY SHEET #: A01 SITE PLAN O 2022 PLUMBING FIXTURES CALCULATION ARCHITECTURAL GENERAL NOTES: Required Fixtures - Males Occupancy Occupant Load Water Closets Lavatories Drinking Fountain Rate Number Rate Number Rate Number E Classrooms 62 1 per 50 1.24 1 per 50 1.24 1 per 100 0.62 E Staff 5 1 per 50 0.10 1 per 50 0.1 1 per 100 0.05 1 Total Required 1 1 WCs Urinals Lavatories DFs Provided Fixtures - Male Classrooms 3 0 4 TOILET 101 0 0 Total Provided 3 0 4 1 Required Fixtures - Females Occupancy Occupant Load Water Closets Lavatories Drinking Fountain Rate Number Rate Number Rate Number E Classrooms 52 1 per 50 1.04 1 per 50 1.04 1 per 100 0.52 E Staff 5 1 per 50 0.10 1 per 50 0.1 1 per 100 0.05 Total Required 1 1 1 WCs Lavatories DFs Provided Fixtures - Female Classrooms 4 5 TOILET 105 1 1 Total Provided 5 6 1 ALL CLASSROOM RESTROOMS ARE HIC ACCESSIBLE DOOR & FRAME TYPES 1 MATCH EXSTG WD FRAME A WOOD DOOR STAIN GRADE MATCH EXST SIZE 2 MATCH EXSTG WD FRAME B SLIDING WOOD DOOR STAIN GRADE 34" X MATCH HT EA LEAF HARDWARE SCHEDULE A. TRIPLE BUTT HINGES (BY MANUF.), DOOR CLOSER (DORMA 7400 SERIES), MORTISE CLASS ROOM LOCK W/ SINGLE ACTION RELEASE DOOR PADDLE (BY MANUF.) , ADA DOOR THRESHOLD, DOOR SWEEP, ASTRAGAL AT DBL DOORS. B. HINGES (2 HAGER, HINGES BB1191), PASSAGE SET (SCHLAGE AL SERIES, ADA SATURN LEVER ), DOOR STOP (TREMCO 7280), 12" H DOOR PROTECTION PLATE AT EACH SIDE OF DOOR (HAGER 204S). C. HINGES (3 HAGER, HINGES BB1191), STORAGE ROOM SET (SCHLAGE AL SERIES, ADA SATURN LEVER), DOOR STOP (TREMCO 7280). D. HINGES (3 HAGER, HINGES BB1191), STORAGE ROOM SET (SCHLAGE AL SERIES, ADA SATURN LEVER) MANUAL FLUSH BOLT (TOP AND BOTTOM OF INACTIVE LEAF) (HAGER MANUAL FLUSH BOLT 283D) ASTRAGAL (HAGER ASTRAGAL 844S). E. HINGES (3 HAGAR, HINGES B131191),STORAGE ROOM SET (SCHLAGE AL SERIES, ADA SATURN LEVER) DOOR CLOSER (DORMA 7400 SERIES), DOOR STOP (TREMCO 7280). F. NOT USED. G. HINGES (3 HAGER, HINGES BB1191), PRIVACY SET (SCHLAGE AL SERIES, ADA SATURN LEVER ), DOOR STOP (TREMCO 7280). 12" H DOOR PROTECTION PLATE AT EACH SIDE OF DOOR (HAGER 204S), DOOR CLOSER (DORMA 7400 SERIES). H. HINGES (3 HAGER, HINGES BB1191), ENTRY/ OFFICE SET (SCHLAGE AL SERIES, ADA SATURN LEVER ), DOOR STOP (TREMCO 7280),12" H DOOR PROTECTION PLATE AT EACH SIDE OF DOOR (HAGER 204S). I. HINGES (3 HAGER, HINGES BB1191), CLASSROOM SET (SCHLAGE AL70PD, ADA SATURN LEVER ), DOOR STOP (TREMCO 7280), 12" H DOOR PROTECTION PLATE AT EACH SIDE OF DOOR (HAGER 204S), DOOR CLOSER (DORMA 7400 SERIES). J. SLIDING DOOR TRACK (SWISCO), FLUSH DOOR PULLS EACH LEAF (IVES FLUSH PULL IVE-222-1326D SATIN CHROME), SLIDING DOOR BUMPER EACH LEAF (SWISCO 80-057) DOOR SCHEDULE KEYEDNOTES: INDICATED BYO SYMBOL PATCH ALL WALLS, FLOORING AND CEILINGS AFFECTED BY WORK TO LIKE -NEW CONDITION. ALL GLAZING SHALL BE "'TEMPERED GLASS. REFERENCE SHEET A5 FOR ALL TOILET INFORMATION AND HC ACCESSIBILITY COMPLIANCE. 1. PROVIDE NEW MILLWORK IN LOCATION SHOWN. MILLWORK TO FIT WIDTH OF EXISTING NICHE IF APPLICABLE. SEE DETAIL 24/A50. TIE INTO EXISTING PLUMBING. 2. WIRE SHELVING 15" X 60" @ 66" A.F.F. 3. PANTRY (NO COOKING) EXISTING 3 COMP SINK INSTALL NEW CASEWORK AND COMMERCIAL DISHWASHER. NEW HANDSINK LOCATIONS. 4. ALIGN WALL W/FACE OF EXISTING CONSTRUCTION. NOTES: • RE -KEY ENTIRE BUILDING. REPAIR/REPLACE DOOR HARDWARE AS NECESSARY TO ENSURE PROPER FUNCTION. • REPLACE ALL WINDOW COVERINGS W/MANUAL, CHILD SAFE CORDLESS LIFT ROLLER SHADES. DOOR 4 DESCRIPTION SIZE MAIL FIRE RATING FRAME DOORTYPE HARDWARE COMMENTS 102 LAUNDRY PR T-0" X 6-8" X 1 3/4" WD 2 B C MATCH EXISTING 107 STAFF PREP T-0" X 6-8" X 1 3/4" WD 1 A J MATCH EXISTING DEMOLITION PLAN SCALE: 1/8" = 1'-0" EXISTING PARTITION NEW PARTITION 1. WE CERTIFY, TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF THAT THE DESIGN OF THE PROJECT COMPLIES WITH THE APPLICABLE PROVISIONS OF THE BUILDING CODE OF FEDERAL WAY, WA ALONG WITH ADOPTED LOCAL AMENDMENTS. 2. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONARY MEASURES TO PROTECT THE PUBLIC AND ADJACENT PROPERTIES FROM DAMAGE THROUGHOUT CONSTRUCTION. 22 IS���11� gg 3. ANY EXISTING UTILITIES TO BE ABANDONED SHALL BE PROPER L4`D'UN�EYE17, PLUGGED OR CAPPED, AS REQUIRED BY CODE OR SOUND CONSTRUCTION PRACTICE. 4. THESE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. ADDITIONAL DATA SHALL BE FROM THE ARCHITECT THROUGH WRITTEN CLARIFICATION ONLY. VERIFY ALL EXISTING CONDITIONS, ELEVATIONS, AND DIMENSIONS BEFORE PROCEEDING WITH ANY PORTION OF ANY WORK. 5. NO CHANGES, MODIFICATIONS OR DEVIATIONS SHALL BE MADE FROM THE DRAWINGS OR SPECIFICATIONS WITHOUT FIRST SECURING WRITTEN PERMISSION FROM THE ARCHITECT. 6. WHERE LACK OF INFORMATION, OR ANY DISCREPANCY SHOULD APPEAR IN THE DRAWINGS OR SPECIFICATIONS, REQUEST WRITTEN INTERPRETATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. 7. ALL WORK AS OUTLINED IN THESE DOCUMENTS, SHALL STRICTLY CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, IN THE EVENT OF A CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN AND BE MET. 8. THE CONTRACTOR SHALL PAY FOR ALL FEES, PERMITS, LICENSES, ETC., NECESSARY FOR PROPER COMPLETION OF THE WORK. 9. PROVIDE ADEQUATE CONCEALED BLOCKING AND ANCHORING FOR ALL CEILING AND WALL MOUNTED EQUIPMENT, HARDWARE AND ACCESSORIES. 10. WHEN A SYSTEM OR ASSEMBLY IS CALLED OUT FOR, ALL NECESSARY PARTS AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION/SYSTEM SHALL BE AND INSTALLED ACCORDING TO THE MANUFACTURERS INSTRUCTIONS. 11. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO DEFINE A COMPLETE FINISHED FACILITY. ANY MATERIAL, SYSTEM, EQUIPMENTS OR ASSEMBLY WHICH NORMALLY WOULD BE REQUIRED SHALL BE PROVIDED AS IF SPECIFICALLY NOTED. 12. DISRUPTED ELECTRICAL AND WATER LINES RE-ROUTED DURING PROJECT CONSTRUCTION ARE TO REMAIN IN CONTINUOUS SERVICE. 13. WHEN WORK IS NOT CALLED OUT AS REQUIRED TO COMPLETE THE PROJECT, IT SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER AND BE OF THE BEST MATERIALS AND WORKMANSHIP. 14. DIMENSIONS ARE SHOWN FROM FACE OF GYPSUM TO FACE OF GYPSUM AND EDGE OF ROUGH OPENING UNLESS NOTED OTHERWISE. 15. COORDINATION. CONTRACTOR SHALL FULLY COORDINATE ALL WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS INTO A SINGLE, UNIFORM PRODUCT. INDIVIDUAL COMPONENTS OF THE WORK, WHETHER WITHIN ONE DISCIPLINE OR OVERLAPPING MULTIPLE DISCIPLINES, AND WHETHER IDENTIFIED IN THE DRAWINGS OR SPECIFICATIONS ARE TO BE CONSTRUCTED AND/OR INSTALLED TO FORM A COHESIVE AND UNIFORM FINISHED PRODUCT. 16. FINISHES. NEW FINISHES ARE TO BE INSTALLED IN A MANNER THAT FULLY COMPLIES WITH THE SPECIFICATIONS AND MANUFACTURER'S RECOMMENDATIONS, OR IF NOT SPECIFICALLY IDENTIFIED, STANDARD INDUSTRY PRACTICE. PAINT, FLOORING, CEILINGS, AND OTHER FINISH MATERIALS ARE TO BE EXTENDED TO THE ROOM WALLS, CORNERS, AND OTHER NATURAL BREAK POINTS IF NOT OTHERWISE SPECIFICALLY IDENTIFIED IN THE DRAWINGS. ALL EXPOSED SURFACES ARE TO RECEIVE A FINISH MATERIAL UNLESS SPECIFICALLY OTHERWISE NOTED. ALL JOINTS BETWEEN ADJACENT FINISH MATERIALS ARE TO BE CLEANLY EXECUTED AND PROVIDED WITH APPROPRIATE TRANSITION MATERIALS. FINAL SELECTIONS SHALL BE MADE BY THE PNC REPRESENTATIVE. 17. MATERIALS. ALL BUILDING MATERIALS SHALL BE RATED AS "NON-COMBUSTIBLE". HWAIYANG A R C H I T E C T S 10314 DONOHO PLACE ST. LOUIS I MISSOURI 1 63131 hwai@hwaiyangarchitects.com 10835 REGISTERED _ABJZBITECT STAT,C-OF WAS+*N4Q-_P0N . Cy") THESE NOTES ARE INTENDED TO COMPLIMENT STANDARD COMMERCIAL CONSTRUCTION SPECIFICATIONS U) O AND DRAWINGS, AND ARE NOT INTENDED AS A COMPLETE DESCRIPTION OF ALL REQUIRED SCOPES OF -aWORK. 86 IN ADDITION TO CONCEPT FLOOR PLANS, FOLLOWING ARE NOTEWORTHY ITEMS TO INCLUDE � O WHILE ESTIMATING INTERIOR TENANT IMPROVEMENT COSTS. -C3 DIVISION 08 00 00 WOOD, PLASTICS 0 N Cz FOR QUALITY AND ESTIMATING PURPOSES, ASSUME THE FOLLOWING LAMINATE TYPES TO BE E M INSTALLED AT ALL NEW CABINETRY AND COUNTER TOPS (NO STONE TOPS): WILSONART, BEIGEWOOD, MATTE FINISH, 7850-60 (CABINETS, LIGHT) O 0 N WILSONART, BRONZE LEGACY, MATTE FINISH, 4656-60 (ENTRY COUNTERTOP, DARK) Q T C3 WILSONART, STUDIO TEAK, LINEARITY FINISH, 796OK-18 (ENTRY CABINETS, DARK) �_ T 70 RECEPTION DESK TO BE CUSTOM BUILT UTILIZING SIMILAR LAMINATES, WITH CAPACITY FOR TWO SCHOOL EMPLOYEES. DIVISION 08 00 00 OPENINGS 08 30 00 - DOORS AND FRAMES 'TIMELY' STYLE, PRE -FINISHED DOOR FRAMES STAIN -GRADE SOLID CORE DOORS WITH COMMERCIAL HARDWARE CLASSROOMS TYPICALLY HAVE AN EXIT DOOR DIRECTLY OUT TO THE PLAYGROUND (IF POSSIBLE), AND A DOOR INTO THE EXIT CORRIDOR 08 81 00 - GLASS GLAZING MINIMUM 4'X6' WINDOWS AND/OR SIDE LIGHTS ALLOWING VISIBILITY INTO EACH CLASSROOM FROM CORRIDORS. NOTE RATED CORRIDORS BELOW. DIVISION 09 00 00 FINISHES 09 21 16 - GYPSUM BOARD ASSEMBLIES JURISDICTIONS TYPICALLY REQUIRE RATED CORRIDORS FOR EXITING PURPOSES. INCLUDE IN INITIAL BUDGET (ARCHITECT TO VERIFY). THIS TRANSLATES TO RATED INTERIOR, DOORS AND FRAMES. 09 51 23 - ACOUSTICAL TILE CEILINGS STANDARD 2X4'SECOND LOOKGRID WITH BASIC ACOUSTICAL TILE nn an nn n nnmmrr, MOHAWK, LIVING LOCAL GLUE DOWN, SABLE 142 RUBBER BASE, BURKE BASIC BROWN NO SPECIAL SOUND OR ACOUSTIC TREATMENT REQUIRED 09 96 43 - FIRE -RATED EXITS EXIT CORRIDORS MAY REQUIRE A 1 HOUR RATING DIVISION 12 06 20 WINDOW TREATMENTS HAND OPERATED ROLL DOWN SHADES FABRIC: SELECTWEAVE S100 S1 OPENNESS FACTOR: 1% COMPOSITION: 25% POLYESTER/75% PVC VINYL ON POLYESTER S1003 NEUTRAUPEARL GRAY DIVISION 27 00 00 COMMUNICATIONS STANDARD CABLE STUBBED INTO SPACE IN ORDER FOR TENANT TO INSTALL WIRELESS INTERNET DIVISION 28 00 00 ELECTRONIC SAFETY AND SECURITY SECURITY KEY PADS AT ALL ENTRIES RECEIVED 7/18/22 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Z z w CD o N � N � `wa CC o 0 U_j Cn O N z N wN CD N Q Y o QC CD LPL PROJECT #: 22-917 FILE NAME: 22-917 CD DRAWN BY: HY CHECKED BY: HY SHEET #: Al 0 DEMO I CONSTRUCTION PLAN CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" SCHEDULED v 3-5/8" KICKERS ATTACHED CEILING @ 4' O.C. MAX. ALTERNATE DIRECTION (IF NEEDED) METAL TRIM - FLOAT AND TAPE; SOUND TAPE AT HEAD - 3-5/8" CHANNEL RUNNERS ATTACHED W/ FASTENERS @ 24" O.C. MAX. EACH SIDE: 5/8" QUIETROCK ES GYP. BD. ATTACHED W/ 1 4" TYPE 'S' SCREWS @ 12" O.C. ALONG EDGES, @ 12" O.C. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF ASSEMBLY. CHANNEL SHAPED 3-5/8" 20 GA. STEEL STUDS @ 16 in. O.C. MAX. z a VINYL, DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS TO JOINTS & SCREW HEADS; PAPER TAPE, 2" WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. 3 2" SOUND BATT INSULATION. FASTEN EA. BATT TO WALLBOARD BASE LAYER W/ MIN. 9/16" STAPLE. 5 STAPLES FOR EA. 4 FT. PIECE. 3-5/8" CHANNEL RUNNERS ATTACHED W/ FASTENERS @ 24" O.C. MAX. SCHEDULED BASE AND FLOORING 47 FINISHED FLOOR 8 @ SIM: 6" CHANNEL RUNNERS & MTL STUDS ATTACHED W/ FASTENERS @ 24" O.C. MAX. /rjn� PARTITION TYPE 2 - ALL PARTITIONS r G SCALE: N.T.S. 0'-A" WA STATE -CH TOILET PARTITION -CLOSED V = V-n" 01 All WA STATE -CH TOILET PARTITION -OPEN 1„=1,0„ LIGHT FIXTURE SCHEDULE A 1 X 4 LED MATCH MATCH EXISTING SURFACE 3500K D EXIT LIGHTS MATCH MATCH EXISTING CHANGE ALL LAMPS TO 3500K IN EXISTING LIGHT FIXTURES. EXISTING SUSPENDED LAY -IN ACCOUSTICAL BD. 5/8" GYPSUM BD. + - EXISTING FRAMING TO REMAIN; MODIFY AS REQUIRED CONTINUOUS REINFORCED FRAMING AT BOTTOM OF HEADER. - CORNER BEAD (TYP); BOTH SIDES .1 Q� WALL HEADER DETAIL ' v / SCALE: 1 1/2" = 1'-O" FA KEYEDNOTES: INDICATED BYO SYMBOL PATCH ALL WALLS, FLOORING AND CEILINGS AFFECTED BY WORK TO LIKE -NEW CONDITION. DEFERRED SUBMITTAL: MODIFY EXISTING FIRE SPRINKLER SYSTEM AS REQUIRED TO ADD NEW SPRINKLER HEADS. FIRE PROTECTION CONTRACTOR SHALL PROVIDE ENGINEERED DRAWINGS AND CALCULATIONS (IF REQUIRED) FOR FIRE SPRINKLER PERMIT SUBMITTAL. EXISTING CEILING AND LIGHTING TO REMAIN UNLESS NOTED OTHERWISE. ALL ROOMS/AREAS WITH EXPOSED CEILINGS SHALL RECEIVE CEILING WHITE PAINT ON ALL EXPOSED STRUCTURAL MEMBERS, DUCTWORK AND CONDUIT/PIPING. ROOF DECK IS APPROXIMATELY 15'-7" A.F.F. NEW CEILING SYSTEM @ 9'-0" IN OFFICE 102, LAUNDRY 104 AND ALL NEW RESTROOMS. REPLACE TILES ONLY IN STAFF 115. ARMSTRONG DUNE 16' TEGULAR SECOND LOOK 2712 W/PRELUDE XL 16' EXPOSED TEE SYSTEM NOTES: • SERVICE ALL HVAC EQUIPMENT AND CHANGE FILTERS. CLEAN ALL DEVICES. SEE MECHANICAL DRAWING FOR ADDITIONAL INFORMATION. 1. HEADER TO REMAIN; SEE DETAIL 18 THIS SHEET. 2. NO CHANGE TO EXISTING LIGHTING. FINISH SCHEDULE NEW LVT FLOORING AND BASE THROUGHOUT ENTIRE INTERIOR. NEW PAINT ON WALLS AND DRYWALL CEILINGS AND SOFFITS THROUGHOUT ENTIRE INTERIOR. FLOOR: MOHAWK LVT LIVING LOCAL GLUE DOWN PLANK; SABLE 142 * IN ALL TOILET ROOMS, USE SHEET VINYL W/INTEGRAL COVE BASE TO MATCH LVT, U.N.O. MOHAWK SHEET VINYL MEDELLA 727 OYSTER WALLS: TRIM SHERWIN WILLIAMS (SW7005- PURE WHITE) SEMI -GLOSS ACCENT #1 - (50% SW1015 - SKYLINE STEEL) LOW SHEEN EGG SHELL ACCENT #2 - (50% SWO066 CASCADE GREEN) LOW SHEEN EGG SHELL ACCENT #3 - (50% SW6242 BRACING BLUE) LOW SHEEN EGG SHELL COMMON AREAS, GENERAL ROOMS, RESTROOMS AND ALL AREAS NOT SPECIFICALLY MENTIONED - (SW7042 - SHOJI WHITE) LOW SHEEN EGG SHELL DOORS & FRAMES: DOORS: STAIN TO MATCH EXISTING FRAME: SW7042 - SHOJI WHITE - LATEX FINISH CEILING: HARD LID/DRYWALL CEILING (SW7005 - PURE WHITE) FLAT BASE: BURKE BASIC BROWN RESTROOMS: BASE SHALL BE CONTINUOUS SHEET VINYL COVE BASE PROVIDE CONTINUOUS JOHNSONITE LOW PROFILE TRANSITION STRIP WHERE VCT MEETS LVT FLOORING. COLOR TO MATCH LVT. ALL FINISHES IN RESTROOMS SHALL COMPLY WITH 2O18 IBC 1209. INTERIOR FINISHES SHALL HAVE A MINIMUM CLASS "C" INTERIOR FINISH RATING. 1" X 1" X 48" FIXED PLASTIC LAMINATE BOARD - MATERIAL TO MATCH CLASSROOM CABINETRY, REF. OUTLINE SPEC o JW WINCO -GN 437 HINGES -ZINC DIE CAST, WITH FRICTION ADJUSTMENT, OR EQUIVALENT FRICTION ADJUSTMENT HINGES 1'-11 1/2" X 1" X 48" PLASTIC LAMINATE PARTITION - MATERIAL TO MATCH CLASSROOM CABINETRY, 47+ REF. OUTLINE SPEC WA STATE -CH TOILET PARTITION DETAIL 1 314" =1'-0" AI A11 Al A A 1^11 WA STATE -CH TOILET PARTITION DETAIL 2 J TA" = r-N, 1" X 1" X 48" FIXED PLASTIC LAMINATE BOARD - MATERIAL TO MATCH CLASSROOM CABINETRY, REF. OUTLINE SPEC JW WINCO -GN 437 HINGES -ZINC DIE CAST, WITH FRICTION ADJUSTMENT, OR EQUIVALENT FRICTION ADJUSTMENT HINGES 1'-11 1/2" X 1" X 48" PLASTIC LAMINATE PARTITION - MATERIAL TO MATCH CLASSROOM CABINETRY, REF. OUTLINE SPEC WIRE SHELVING, REF. OUTLINE SPEC I -,S L- I I IIL 5-1U I1L I -0 _ 4" WA STATE -CH TOILET WA STATE -CH TOILET PARTITION -SIDE n PARTITION -FRONT ELEVATION -CLOSED n ELEVATION -CLOSED 112" =1'-0" U 112" =1'-0" WIRE SHELVING, REF. OUTLINE SPEC 4" WA STATE -CH TOILET WA STATE -CH TOILET PARTITION -SIDE n PARTITION -FRONT ELEVATION -OPEN n ELEVATION -OPEN U 1/2" =1'-0" L 112" =1'-0" WIRE SHELVING, REF. OUTLINE SPEC 1" X 2" SUPPORT COLUMN TO MATCH PARTITION MATERIAL. EXACT HEIGHT DEPENDANT ON CASTERS USED 2" HARD RUBBER THREADED STEM CASTER CEILING PLAN SCALE: 1/8" = 1'-0" O U 1 108 EX CLASSROOM 3 107 AG GROUP: TODDLERS AREA: 1012 SF 173 SF/CHILD STAFF ROOM OCCUPANCY: 29 1 ENROLLMENT: 14 E: 16-36 MONTHS 2 COT 106 0 CLASSROOM 2 AGE GROUP:HOUSE 105 N AREA: 1284 SF 1 9 SF/CHILD 1284S 14 OCCUPANCY: 37 1 ENROLLMENT: 26 CORRIDOR AGE: 3-6 MONTHS 10 EX TO u WH W'D 101B 10BA DW nu PT EX TOILET 2 � 2 O O 103 102 101A EX PANTRY STAFF BREAK EX C 1 104A EX TOILET EX OILET REF 101 EX RECEPTION O 1 os O EX CLASSROOM 4 104 U O AGE GROUP: NIDO EX CLASSROOM 1 AREA: 828 SF 173 SF/CHILD OCCUPANCY: 29 1 ENROLLMENT: 8 AGE GROUP: CHILDREN'S HOUSE AGE: 6 WEEKS -16 MONTHS AREA: 1122 SF 143 SF/CHILD OCCUPANCY: 32 1 ENROLLMENT: 26 ® 02 AGE: 3-6 MONTHS 100 EX VESTIBULE F,10 EX OFFICE f�.t►.IIi[17v.Lr-Dl HWAIYANG A R C H I T E C T S 10314 DONOHO PLACE ST. LOUIS I MISSOURI 1 63131 hwai@hwaiyangarchitects.com 10\835 REGISTERED �> _A2GkI.ITECT STA OF WAT�N .L O M p U) 0 U)Q oo -C3 cz0 cz 3: N E M cz T 0^, =3 W RECEIVED 7/18/22 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Z z "' CDC)N � N V `w w o n- cn y CD N Z z N wNCD CD.< CV z o OCD C� Q Y u_ PROJECT #: 22-917 FILE NAME: 22-917 CD DRAWN BY: HY CHECKED BY: HY SHEET #: A20 CEILING I FLOOR FINISH PLAN & DETAILS BREAK ROOM/MILLWORK NOTES: NOTES: KEYED NOTES: INDICATED BYO SYMBOL PROVIDE CABINET PULLS ON ALL CABINETS AND DRAWERS: TBD`U ELL 11L/\ I U I LL I DESIGNS BELOW BASED ON 2010 ADA GUIDELINES FOR CHILDREN'S TOILETS SECTION 604.9 AND PATCH ALL WALLS, FLOORING AND CEILINGS AFFECTED BY WORK TO LIKE -NEW CONDITION. j GRAB BARS UNDER SECTION 609.4. PLASTIC LAMINATE ON CABINET FRONTS AND COUNTERTOPS: WILSONART, BEIGEWOOD, P1. RELOCATE EXISTING HC TOILET. MATTE FINISH, 7850-60 (CABINETS, LIGHT) Water 604.9 Water Closets and Toilet Compartments for Children's Use. Wat ° P2. NEW ADULT HC TOILET. PROVIDE SELF, SOFT -CLOSING HARDWARE ON ALL DRAWERS AND DOORS. 1 3 closets and toilet compartments for children's use shall comply with 604.9. 1/2" PLYWOOD L P3. EXISTING TOILET. 2 2 —10 2 9 8 9 PROVIDE 2 BBF PEDESTALS; PLAM TO MATCH MILLWORK ZLiv BACK ON 1 X4 Advisory 604.9 Water Closets and Toilet Compartments for _ CLEATS Children's Use. The requirements in 604.9 are to be followed P4. SINK @ STD HEIGHT 34" A.F.F. GC IS RESPONSIBLE FOR PROVIDING POWER AND WATER (BUT NOT LIMITED) TO THE LL 101 A where the exception for children's water closets in 604.1 is KOHLER GREENWICH WALL MOUNT SINK K 2032 0 H W A I Y A N G FOLLOWING APPLIANCES: = =INd a used. The following table provides additional guidance in • REFRIGERATORS - '� EX J C 1 P5. SINK @CHILD HEIGHT 24" A.F.F. A R C H I T E C T S • COFFEE MACHINES = = r applying the specifications for water closets for children FAUCET • MICROWAVES = 3/4" SUBSTRATE according to the age group served and reflects the differences 1 0 3 1 4 D O N O H O PLACE • DISHWASHER = = CLAD IN PLASTIC X TOI ET in the sizestatureand reach ranges of children ages 3 P6. HALF DOOR. ST. LOUIS MISSOURI 63131 - - , , 3/4" LAMINATE (FRONT hwai@hwaiyangarchitects.com • GARBAGE DISPOSAL = = AND BACK) through 12. The specifications chosen should correspond to P7. 24" X 42" DIAPER CHANGING TABLE W/3" RADIUS EDGE; PROVIDE CONTINUOUS RUBBER - - 3/4" SUBSTRATE DOOR CLASSROOM SINKS: PROVIDE JUST MANUFACTURING SLN-ADA-17519-A-GR, SINGLE BOWL CLAD IN PLASTIC the age of the primary user group. The specifications of one EDGING ON EXPOSED EDGES. OF01. TOP MOUNT STAINLESS STEEL SINK OR APPROVED EQUAL. _ = LAMINATE (FRONT ® age group should be applied consistently in the installation of a AND BACK); CONCEALED SOFT water closet and related elements. P8. PARTIAL HEIGHT WALL 48" TALL. CLOSE HINGES 10835 3 COMPARTMENT SINK: ONE PIECE, STAINLESS STEEL, SEAMLESS DEEP DRAWN SINK BOWL = REGISTERED DESIGN. ELKAY LUSTERTONE CLASSIC STAINLESS STEEL 46" X 22" X 7 5/8" TRIPLE BOWL - Advisory Specifications for Water Closets Serving P9. ADA PAPER TOWEL DISPENSER. DROP -IN SINK MODEL(S) LTR4622 OR APPROVED EQUAL. MOUNTING CLIPS PROVIDED = = 3/4" ADJUSTABLE PLASTIC BOBRICK CLASSIC SERIES B-262 LAMINATE SHELF WITH II/2" = Children Ages 3 through 12 ACCOMMODATE ALL THICKNESSES OF COUNTER. - FRONT LIP ON STANDARDS INTERIOR 3/4" ADJUSTABLE AND BRACKETS (RECESSED OF SHELF CLAD IN Ages 5 throughAges 9 through P10. ADA SOAP DISPENSER. I L ANG INSIDE PANELS) ET PLASTIC LAMINATE Ages 3 and 4 S 12 BOBRICK CONTURA SERIES 818615 CL1AD WITH 1 1/2" FRONT g S E OF WASHINGTON I HITE LIP ON STANDARDS Water 12 inches 12 to 15 15 to 18 KUTOL UNIVERSAL SOAP DRIP TRAY 9908ZPL; WHITE MELAMINE AND BRACKETS (RECESSED INSIDE Closet (305 mm) inches (305 to inches (380 to P11. MOUNT PTO ON WALL PERPENDICULAR TO AND IN FRONT OF CABINETS IF POSSIBLE; LAMINATEPLA PANELS) Centerline 380 mm) 455 mm) OTHERWISE MOUNT AS SHOWN. LAMINATE SURFACE W/ `� IIIIIENLARGED N I DO EX TOILET, TYP. _ = BEVEL EDGE 1 O Toilet 11 to 12 12 to 15 15 to 17 SCALE: 1/4" = 1' o" Seat inches (280 to inches (305 to inches (380 to NOTES: PLASTIC LAMINATE o w Height 305 mm) 380 mm) 430 mm) • FAUCET @ ALL RESTROOM SINKS: ON UNDERSIDE Q w OF 3/4" PLYWOOD Grab Bar 16 to 20 20 to 25 25 to 27 AMERICAN STANDARD MONTERREY 7500.170 � � `�'- a w Height inches (455 to inches (510 to inches (635 to CENTERSET GOOSENECK, CHROME 2'-1 0 510 mm) 635 mm) 685 mm) Dispenser 14 inches 14 to 17 17 to 19 FAUCET @ ALL CLASSROOM SINKS: OUTLET LOCATION, TYP. 1 1/4" COUNTERTOP AMERICAN STANDARD MONTERREY 6540.178 PLASTIC LAMINATE Height (355 mm) inches (355 to inches (430 to GOOSENECK, CHROME M 4" PLAM TO O MATCH COUNTER 430 mm) 485 mm) • FAUCET @ PANTRY HAND SINK AMERICAN STANDARD MONTERREY 6409.170 ° GOOSENECK, CHROME 3/4" ADJUSTABLE SPLASTIC LAMINATE 1 ) HELF CLAD IN �\ 3/4" SUBSTRATE DOOR • SERVICE ALL PLUMBING FIXTURES. JET ALL SEWER LINES. WITH 1 1/2" FRONT CLAD IN PLASTIC ° ON STANDARDS AND LAMINATE (FRONT 101 B 108A • REPLACE ALL DAMAGED TOILET ACCESSORIES. 1/2" PLYWOOD BACK BRACKETS (RECESSED = y ON 1 X 4 CLEATS - INSIDE PANELS) _ AND BACK) INTERIOR OF 3/4" SUBSTRATE DOOR o CABINET CLAD EX TOILET ACCESSORIES SCHEDULE: IN WHITE CLAD IN PLASTIC 10 a MELAMINE NIDO LAMINATE (FRONT 1/2" PLYWOOD BACK _ PLEASE REFERENCE PLUMBING SHEET P-001 FOR FIXTURE SCHEDULE. AND BACK); CONCEALED SOFT ON 1 X 4 CLEATS CLOSE HINGES = o A. TOILET PAPER DISPENSER - BOBRICK SERIES B-6867 ADA COMPLIANT DOUBLE ROLL 0 DISPENSER w GAP BETWEEN BOTTOM BASE AS G O G B. 36" GRAB BAR - BOBRICK B-5806 X 361-1/4" DIAMETER STRAIGHT GRAB BAR q -2 8" C. 42" GRAB BAR - BOBRICK B-5806 X 42 1-1/4" DIAMETER STRAIGHT GRAB BAR t� OF DOOR PANEL AND FINISHED 'v SCHEDULED FLOOR 101 A 3" 2'-6" MIN. P9 D. 18" GRAB BAR - BOBRICK B-5806 X 18 1-1/4" DIAMETER STRAIGHT GRAB BAR NOTES: `� C E. MIRROR - BOBRICK B-165 2430 CHANNEL FRAME EASED EDGES 3MM PVC MATCHING FACE PLASTIC LAMINATE FACES. PLUS MINUS 1/16 TO 1/8 o k,—� INCH RADIUS FRONT, BACK AND CORNERS.F. MIRROR - BOBRICK B-165 2436 CHANNEL FRAME 0 �EDGEE DETAIL @ DOORS AND COUNTERTOPS COT STORAGE CABINET SECTION CABINET SECTION ENLARGED TODDLER HC TOILET, TYP. T T T G. 15"X FULL LENGTH WIRE SHELF@ 60" A.F.F. 3'-0" 22.T.S.SCALE: 1" = 1'-0" 14 ScALE: 1" = 1' 0" 0 SCALE: 1/4" = 1' 0" 9'-0" 1' 6" 1'-6" 1'-6" 1'-6" 11 1'-6" 11 1'-6" .� CM O CA I UIL YOUNG TODDLERS TODDLERS f� -a0000 N O7 �--� >, � 5'-0" / v / v / v CZ = CZ DW - / \ / \ / \ M 3: 1/2" PLYWOOD G 6„ G "' C- �� BACKON1X4 ° M N CLEATS \ / \ / \ / C/� CZ ° \\I 0// \\� �// \\0 0// O N LL CV ------------ o 70 r� P9 • — / 0 0 \ = 3/4" SUBSTRATE ° - \ - C A N J o / / \ \ CLAD IN PLASTIC EX PAN - A -1 o - CD `~ O N N N N = 3/4" LAMINATE (FRONT /I 0\ \ / \ = AND BACK) Fr*-rl j / 3' 0111 v 1-0 1-0 N v 0 EX OILET N M M v v 40 INTERIOR 3/4"ADJUSTABLE CHILDREN'S HOUSE 3'-0" T-0" 3'-0" • OF SHELF CLAD IN • CABINET PLASTIC LAMINATE CLAD WITH 1 1/2" FRONT IN WHITE LIP ON STANDARDS MELAMINE AND BRACKETS (RECESSED INSIDE 6 PANELS) E 4'-6" *��E: T�/8T=� GE MILLWORK ELEVATION ENLARGED CHILDREN'S HOUSE EX TOILET, TYP. 3_D STAFF ELEVATION ' 0" = SCALE: 1/4" = 1'-0" p SCALE: 3/8" = 1' 0" PLASTIC LAMINATE B 1 8,_0„ ON UNDERSIDE 2'-1 a ELKAY STAINLESS STEEL SINK C P9 B RECEIVED OF 3/411 PLYWOODELUHAD2115PD MODEL 55 C 51-011 2'-0" 2'-0" 2'-0" 2'-0" o - -N Cl? 7 / 18 / 2 2 M 4" PLAM BACK N ff I- N N o - SPLASH TO MATCH _ o _ N N _ A N CITY OF FEDERAL WAY COUNTER 1 1/4" COUNTERTOP 3'-0" COMMUNITY DEVELOPMENT PLASTIC LAMINATE w CD c� in LL / \ / \ O N ILL z ADULT v ' ` ' LU LU w w 1/2" PLYWOOD -A; 8" MIN. J o d 911 911 C K ON 11 X4 CLEATS 101 B 108A Z N o P9 GE GFC520V%HP GARBAGE DISPOSER o Z w N O `l' P11 P10 ;/ E EX TOILET F 3' 3" N Q co - J 3/4" SUBSTRATE DOOR � I CLAD IN PLASTIC / 8" 4' 6" P LAMINATE (FRONT L�11 AND BACK) 611 3_0 Pi N _ = CLEAR SPACE �R � P9 0 D o REQUIRED FOR o o / ACCESSIBLE C _ B c� A / \ / N b SINK SHOWN -iir= A \ \ / / \ \ / / PROJECT #: 22-917 - DASHED A o v o c? FILE NAME: 22-917_CD SIDEWALL CLEAT 101 A "' N N 'r' DRAWN BY: HY WITH ROLLER7 1SHEET #: ' 11" 2'-0" 5'-0" CHECKED BY: HY 4'-0" 4'-0" 6" MAX. CATCH, TYP. 11 -*-- I I I �l� I /Ei 1, �—�(+' 1'-5" MIN. K EX v i� 1'-6" 31-611 -Ir A30 ' RESTROOM PLANS & DETAILS MILLWORK HI � LO MILLWORK UTILITY SINK ELEVATION i CABINET SECTION @SINK i ENLARGED STAFF EX HC TOILET, TYP. Q HC TOILET ELEVATIONS, TYP. ^ PANTRY ELEVATION Get SCALE: 3/8" = 1'-0" v SCALE: 1" = 1' 0" G SCALE: 1/4" = 1' 0" V SCALE: 1/4" = 1'-0" SCALE: 3/8" = 1'-0" PLUMB NG LEGEND S SANITARY, WASTE BELOW FLOOR — S, W, SAN S SANITARY, WASTE ABOVE FLOOR — S, W, SAN ST STORM BELOW FLOOR — ST VENT PIPING — V COLD WATER PIPING — CW — — HOT WATER PIPING — HW CLEANOUTS — CO, WCO, FCO, GCO �i GATE VALVE — GV S BALL VALVE — BV x]O FLOOR DRAIN — FD, FD—* CONNECT TO EXISTING — CTE x> P—TRAP A/C ABOVE CEILING A/F ABOVE FLOOR B/F BELOW FLOOR B/G BELOW GRADE CD CONDENSATE DRAIN CO CLEAN OUT CW COLD WATER DN DOWN DSN DOWNSPOUT NOZZLE ERL EMERGENCY ROOF DRAIN/LEADER EX EXISTING FCO FLOOR CLEANOUT FD FLOOR DRAIN HW HOT WATER HWC HOT WATER CIRCULATING IWH-1 INSTANTANEOUS WATER HEATER NFWH NONFREEZE WALL HYDRANT P—* PLUMBING FIXTURE PD PUMPED DISCHARGE RD/OD ROOF DRAIN/OVERFLOW DRAIN RW/ORW ROOF DRAIN WATER PIPE/OVERFLOW ROOF DRAIN WATER PIPE SS SANITARY SEWER V VENT VTR VENT THROUGH ROOF W WASTE WCO WALL CLEANOUT PLUMBING NOTES 1. SCOPE OF WORK A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED. B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES GOVERNING WORK OF THIS NATURE. C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS. D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED EQUAL" BY ENGINEER OR ARCHITECT. 2. PERMITS A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES. 3. SHOP DRAWINGS A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT/FIXTURES TO THE ARCHITECT OR ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT AN ELECTRONIC SET OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED. 4. DOMESTIC WATER SUPPLY PIPING A. UNDERGROUND: PROVIDE TYPE 'Y' SOFT DRAWN COPPER TUBING WITH BRAZED CONNECTIONS. B. ABOVE GROUND: PROVIDE TYPE Ill HARD DRAWN COPPER TUBING WITH 125 PSI SOLDER JOINTS, COPPER OR BRASS FITTINGS. ALL SOLDER TO BE "NO LEAD" TYPE. C. ALL HOT WATER PIPING 1-1/2" OR LESS TO BE INSULATED WITH 1" FIBERGLASS INSULATION, OVER 1-1/2" INSULATE WITH 1-1/2" INSULATION. D. ALL COLD WATER PIPING 1-1/2' OR LESS TO BE INSULATED WITH 1/2" FOAM INSULATION, OVER 1-1/2" INSULATE WITH 1" INSULATION. 5. SANITARY/STORM DRAINAGE AND VENT PIPING A. ABOVE GRADE: —2" AND BELOW: SCH. 40 GALV. STL. PIPE WITH SCREWED ENDS OR SCH. 40 PVC WITH SOLVENT JOINTS OR DWV COPPER WITH SOLDER JOINTS. ALL SOLDER TO BE "NO LEAD" TYPE. —Y AND ABOVE: SERVICE WT. CAST IRON WITH NO —HUB OR BELL AND SPIGOT JOINTS; OR SCH. 40 PVC WITH SOLVENT JOINTS. B. BELOW GRADE: SERVICE WT. CAST IRON WITH BELL AND SPIGOT JOINTS OR SCH. 40 PVC WITH SOLVENT JOINTS. C. PVC PIPING SHALL NOT BE USED IN AIR PLENUM CEILINGS AND SHALL NOT CROSS FIRE RATED WALLS, CEILINGS, OR FLOORS. D. DRAINAGE PIPING SHALL BE RUN AS STRAIGHT AS POSSIBLE AND SHALL HAVE LONG TURN FITTINGS. E. DRAINAGE PIPING 3" SIZE AND SMALLER SHALL RUN AT A UNIFORM GRADE OF AT LEAST 1/4" PER FOOT, AND PIPING LARGER THAN 3" SHALL BE RUN AT A GRADE OF NO LESS THAN 1/8" PER FOOT. F. ALL VENT PIPING SHALL BE SLOPED TO DRAIN BACK TO FIXTURES. G. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FLASHING OF THE VENT PIPING RUN THROUGH THE ROOF. 6. PENETRATIONS A. ALL STUB —INS AND/OR SLAB OR WALL PENETRATION TO BE PER INTERNATIONAL PLUMBING CODE. ALL PIPING PENETRATIONS OF BUILDING FOUNDATIONS OR FOOTINGS SHALL BE SLEEVED. 7. GAS PIPING A. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUTOFF VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS. B. GAS PIPING SHALL BE PAINTED WITH RUST INHIBITING PAINT IN SAFETY YELLOW. 8. PIPE SUPPORTS A. ABOVE GRADE ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE AND PERFORMED METAL TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL BE AS SPECIFIED IN THE INTERNATIONAL PLUMBING CODE. B. BELOW GRADE EARTH SHALL BE EXCAVATED TO A MINIMUM DEPTH WITH AN EVEN SURFACE TO INSURE SOLID BEARING OF PIPE FOR ITS ENTIRE LENGTH. —INTERIOR: THE PIPE SHALL BE INSTALLED (UNLESS OTHER— WISE SPECIFIED) A MINIMUM OF 4 INCHES BELOW THE BOTTOM OF THE SLAB AND SHALL NOT BE IN ANY DIRECT CONTACT WITH THE CONCRETE AT ANY POINT. —EXTERIOR: THE WATER PIPE SHALL HAVE A MINIMUM OF 42" OF COVER AND THE SANITARY WASTE PIPE SHALL HAVE A MINIMUM OF 24" OF COVER. 9. MISCELLANEOUS A. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION. B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE. C. THE PLUMBING PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURER'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE SPACE. D. CONNECTION TO EXISTING PIPING SHALL CONNECT TO EXISTING PIPE OF EQUAL SIZE OR LARGER. 10. TESTING A. PLUMBING SYSTEMS SHALL BE FLOW AND PRESSURE TESTED IN ACCORDANCE WITH STANDARD PRACTICE AND THE INTERNATIONAL PLUMBING CODE. 11. GUARANTEE A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. AR D STR BUT ON DEVICES TAG DUTY SIZE MOUNTING MATERIAL TYPE DESIGN BASIS ACCESSORIES FACE SIZE/CEILING MODULE NECK TYPE A SUPPLY 2424 VARIES (SEE DRAWINGS) T—BAR/LAY—IN STEEL PLAQUE FACE CEILING SUPPLY DIFFUSER. TITUS OMNI 2-104E89 NOTES & ACCESSORIES: 1. CONFIRM MOUNTING REQUIREMENTS (E.G. CEILING TYPE) WITH ARCHITECTURAL DRAWINGS. 2. FINISH SHALL BE BAKED WHITE ENAMEL. FINAL COLOR SELECTION BY ARCHITECT. 3. INSULATE BACKSIDE OF AIR DISTRIBUTION DEVICE. ACCEPTABLE ALTERNATE MANUFACTURERS: PRICE, KRUEGER, NAILOR FANS MARK QUANTITY SERVICE CFM E.S.P. (IN. W.G.) MAX INPUT WATTS FAN RPM FAN DRIVE ELECTRICAL SERVICE (VOLTS/PHASE) DESIGN BASIS NOTES & ACCESSORIES EF—A 1 RESTROOM EXHAUST 156 0.375 23 1,400 DIRECT 115/1 GREENHECK SP—A190 ALL NOTES & ACCESSORIES: 1. GRAVITY BACKDRAFT DAMPER. 2. SWITCH WITH LIGHTS OF AREA SERVED. ACCEPTABLE ALTERNATE MANUFACTURERS: COOK, PENN—BARRY PLUMBING FIXTURE SCHEDULE FIXTURE DESCRIPTION MANUFACTURER PIPING CONNECTIONS S W VENT C. W. H.W. & CAT. NO. MOP SINK — FLOOR MOUNTED FIAT MSB-2424 3" 2" 3/4" 3/4" MOLDED STONE, FLOOR MOUNTED, MOP SERVICE BASIN WITH STAINLESS STEEL STRAINER. WALL MOUNTED MIXING FAUCET. 1/2" I.P.S. ANGLE P-1 FIAT #830—AA HOT AND COLD WATER SUPPLIES WITH LOOSE KEY STOP. FIAT #832—AA WALL —MOUNT, VITREOUS CHINA, WITH OVERFLOW, 21-1/4" X 18-1/8". PROVIDE WITH AMERICAN STANDARD MONTERREY 7500.170 CENTERSET P-2 LAVATORY WALL —MOUNT KOHLER GREEENWICH 1-1/2" 1-1/4" 1/2" 1/2" GOOSENECK, CHROME WITH 0.5 GPM AERATOR AND McGUIRE "PROWRAP" MODEL PW2125 OFFSET WASTE WITH P—TRAP, GUARD WASTE, AND K-2032-0 SUPPLIES ALL COATED WITH SEAMLESS ANTI—MICROBRIAL PIPE INSULATOR MADE OF PVC RESIN EQUAL TO TRUEBRO LAV GUARD UNDERCOUNTER PIPING. PROVIDE PROTECTIVE COVER OVER P—TRAP AND WATER SUPPLIES. TEMPERING VALVE, TACO 5120 OR EQUAL TO MAINTAIN 1107 OR LESS TO LAVATORY. P-3 WATER CLOSET — FLOOR MOUNT AMERICAN STANDARD 10" 3" 2" 1/2" N/A WHITE VITREOUS CHINA, ROUND FRONT SIPHON ACTION BOWL, 1.28 GPF FLUSH TANK —TYPE, PROVIDE WITH AN OPEN —FRONT SEAT, OLSONITE #95 BABY DEVORO OR EQUAL. JUST USN-1620—A P-4 KITCHEN SINK — UNDERMOUNT McGUIRE 2165 L/K UNDERMOUNTED MOUNTED SINGLE COMPARTMENT, 18 GAUGE STAINLESS STEEL SINK, 20" X 16" X 8" DEEP. PROVIDE GOOSENECK FAUCET WITH JUST J-35 2" 1-1 / 2" 1/2" 1/2" 10" REACH, PULL DOWN HAND SPRAY, BRASS SWING SPOUT, SINGLE LEVER HANDLE, 1.5 GPM SPRAY OUTLET. 1/2" ANGLE HOT AND COLD McGUIRE 8904 WATER SUPPLIES WITH LOOSE KEY STOP. STAINLESS STEEL CRUMB CUP STRAINER WITH REMOVABLE BASKET. 2" CHROME PLATED, 17 GAUGE, AMERICAN STANDARD — CAST BRASS P—TRAP W/ CLEANOUT & ESCUTCHEON. 7105.801 STUDIO S WIDESPREAD P-5 WASHER BOX GUY GRAY 2" 2" 1/2" 1/2" WASHING MACHINE OUTLET BOX SHALL BE FURNISHED WITH 1/2" MIP/SWEAT CONNECTION VALVES AND A 2" THREADED DRAIN FITTING B200 AND LOCKNUT. JUST SL—ADA-17519—A—GR SINGLE COMPARTMENT, 18 GAUGE STAINLESS STEEL SINK, 17-1/2" X 19" X 6-1/2" DEEP. TWO HOLE CENTER PUNCHED. AMERICAN STANDARD 7105.801 2" 1-1/2" 1/2" 1/2" DECK MOUNTED MIXING FAUCET WITH 4-7/8" REACH, BRASS SPOUT, 1.5 GMP OUTLET. WATERSENSE COMPLIANT 1/2" ANGLE HOT AND COLD P-6 SINK — CLASS ROOM STUDIO S WIDESPREAD, CHROME WATER SUPPLIES WITH LOOSE KEY STOP. STAINLESS STEEL CRUMB CUP STRAINER WITH REMOVABLE BASKET. 2" CHROME PLATED, 17 GAUGE, McGUIRE 2165 L/K CAST BRASS P—TRAP W/ CLEANOUT & ESCUTCHEON. TEMPERING VALVE, TACO 5120 OR EQUAL TO MAINTAIN 110°F OR LESS TO LAVATORY. JUST J-35 P-7 TOILET —FLOOR MOUNTED 3" 2" 1" N/A FLOOR MOUNTED, 1.28 GPF FLUSH TANK —TYPE, PRESSURE ASSISTED ELONGATED VITREOUS CHINA, CLOSED FRONT, ADA COMPLIANT. FLUSH AMERICAN STANDARD HANDLE TO BE ON WIDE SIDE OF ROOM/STALL. WATER SENSE COMPLIANT. TOWN SQUARE S NOTES 1. PROVIDE FIXTURES AS SPECIFIED BY ARCHITECT/ENGINEER OR APPROVED EQUAL BY ARCHITECT/ENGINEER AND OWNER. 2. CONTRACTOR SHALL COORDINATE INSTALLATION REQUIREMENTS. 3. PROVIDE SIZE —A WATER HAMMER ARRESTOR AT EACH FLUSH VALVE PLUMBING FIXTURE. IE. URINALS, AND WATER CLOSETS. HWAIYANG A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS I MISSOURI 1 63131 hwai®hwaiyangarchitects.com TLCENGINEERING SOLUTION S 4360 Chamblee Dunwoody Rd ©Copyright 2021 Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 a O U cz O E czcn Z� L U .i `- CL) (3.) 70 .=3 0) RECEIVED 7/18/2 Z CITY OF FEDI1MhL WAY COMMUNITY DEI4&ELOPMENT � z o C4 ~_ a Z CD U w V 0 w 0 0C) LPL z w G cD z o W Q V+ o � y PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: ZP CHECKED BY: LF SHEET #: mp000 MECHANICAL & PLUMBING GENERAL NOTES, 9 22-102989 KEY NOTES: APPLY THIS SHEET ONLY O EXISTING EXHAUST FAN TO BE REPLACED. SEE FAN SCHEDULE ON MP/O.O. 0 EXISTING WATER HEATER TO REMAIN. O3 REMOVE FIXTURE. CUT AND PREPARE EXISTING COLD WATER, HOT WATER, SANITARY, AND VENT FOR SIMILAR FIXTURE IN SIMILAR LOCATION. ® REMOVE FIXTURE. CUT AND PREPARE EXISTING COLD WATER, SANITARY, AND VENT FOR SIMILAR FIXTURE IN SIMILAR LOCATION. O REMOVE FIXTURE. CUT AND CAP EXISTING COLD WATER, HOT WATER, SANITARY, AND VENT. © REMOVE FIXTURE. CUT AND CAP EXISTING COLD WATER, SANITARY, AND VENT. FLOOR PLAN -MECHANICAL &PLUMBING DEMO SCALE: 1 /4" = 1 '-0" v v NORTH HWAIYANG A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS 1 MISSOURI 1 63131 hwai®hwaiyangarchitects.com ENGINEERING ,&jTLC SOLUTIONS. ©Copyright 2021 4360 Chamblee Dunwoody Rd Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 O U a C/) G.) }, C- x O a. E C90 Z� }, U) CU � "> C O 7C:3 4— Q� (2) RECEIVED 7/18/2 Z CITY OF FEDRM1L WAY COMMUNITY DFALOPMENT z 0 r E U CIO cn Uj LU Q 0 Y Q H C4 Z C) / V 0 U_ Ifl W C4 C r PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: ZIP CHECKED BY: LF SHEET #: mpi 0 ■ MECHANICAL & PLUMBING DEMO PLAN FLOOR PLAN - MECHANICAL & PLUMBING NEW WORK SCALE:1/4" = 1'-0" X-oiv 22-102989 'JENERAL NOTES: kPPLY TO THIS SHEET ONLY CONTRACTOR TO ADJUST EXISTING DIFFUSER LOCATIONS AS REQUIRED TO ACCOMMODATE UPDATED FLOOR PLAN AND CEILING GRID. KEY NOTES: APPLY THIS SHEET ONLY D1 INSTALL NEW EXHAUST FAN ABOVE CEILING. CONNECT TO EXISTING EXHAUST DUCT. D ROUTE SUPPLY DUCT FOR NEW SUPPLY DIFFUSER TO NEAREST TRUNK DUCT. COORDINATE EXACT LOCATION WITH UPDATED LIGHTING PLAN. EXISTING WATER HEATER TO REMAIN. NEW FIXTURE. CONNECT TO EXISTING COLD WATER, HOT WATER, SANITARY, AND VENT IN WALL. D NEW FIXTURE. CONNECT TO EXISTING COLD WATER, SANITARY, AND VENT IN WALL AND BELOW FLOOR. 0 ROUTE 2" SANITARY PIPE TO EXISTING SANITARY PIPE OF EQUAL SIZE OR O LARGER. 7 ROUTE 1-1/2" VENT PIPE TO EXISTING VENT PIPE OF EQUAL SIZE OR LARGER. ® ROUTE 2" VENT PIPE TO EXISTING VENT PIPE OF EQUAL SIZE OR LARGER. 0 ROUTE 1/2" COLD WATER PIPE TO EXISTING COLD WATER PIPE OF EQUAL SIZE OR LARGER. 10 ROUTE 3/4" COLD WATER PIPE TO EXISTING COLD WATER PIPE OF EQUAL SIZE OR LARGER. 11 ROUTE 1/2" HOT WATER PIPE TO EXISTING HOT WATER PIPE OF EQUAL SIZE OR LARGER. 12 ROUTE 3/4' HOT WATER PIPE TO EXISTING HOT WATER PIPE OF EQUAL SIZE OR LARGER. 13 3/4" COLD WATER PIPE DOWN. ROUTE 1/2" COLD WATER TO EACH SINK. 14 3/4" HOT WATER PIPE DOWN. ROUTE 1/2" HOT WATER PIPE TO EACH SINK. HWAIYANG A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS 1 MISSOURI 1 63131 hwai®hwaiyangarchitects.com ENGINEERING ,&jTLC SOLUTIONS. ©Copyright 2021 4360 Chamblee Dunwoody Rd Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 O U a G.) }, cz Cz x Cz C90 CD }, U) CU � "> C O = 7 (2) 7C:3 s= RECEIVED 7/18/2 Z CITY OF FEDRM1L WAY COMMUNITY DFALOPMENT � z o C4 Z C)L U V 0 w Q CD O LL. z w 11= cD LJJ z o QY C/) � C4 o � PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: ZP CHECKED BY: LF SHEET #: MP200 MECHANICAL & PLUMBING NEW WORK FLOOR PLANS ELECTRICAL SYMBOLS LEGEND �X DUPLEX RECEPTACLE, 20A, 125V, 2 POLE, 3 WIRE, GROUNDING (X DENOTES TYPE BELOW) c - COUNTER TOP HEIGHT OR 44" ABOVE FINISHED FLOOR GFCI - GROUND FAULT CIRCUIT INTERRUPT WP - WEATHERPROOF (WHILE IN USE) TR - TAMPER RESISTANT 5/GFCI - GFCI MOUNTED ABOVE COUNTER w%FcI - GFCI WEATHERPROOF #X QUAD RECEPTACLE, 20A, 125V, 2 POLE, 3 WIRE, GROUNDING (X DENOTES TYPE BELOW) c - COUNTER TOP HEIGHT OR 44" ABOVE FINISHED FLOOR ® DUPLEX RECEPTACLE, 20A, 125V, 2 POLE, 3 WIRE, GROUNDING, FLOOR MOUNTED, UNO. ® DUPLEX RECEPTACLE, 20A, 125V, 2 POLE, 3 WIRE, GROUNDING, CEILING MOUNTED, UNO. ONEMA SPECIAL PURPOSE RECEPTACLE, WALL MOUNTED, UNO. NEMA CONFIGURATION AS NOTED ON THE THE DRAWINGS. JUNCTION/PULL BOX, WALL MOUNTED, UNO. PROVIDE SIZE AS REQUIRED PER 4 NEC REQUIREMENTS. O JUNCTION/PULL BOX, CEILING MOUNTED, UNO. PROVIDE SIZE AS REQUIRED PER NEC REQUIREMENTS. JUNCTION/PULL BOX, FLOOR MOUNTED, UNO. PROVIDE SIZE AS REQUIRED PER NEC REQUIREMENTS. DISCONNECT SWITCH. SEE MECHANICAL EQUIPMENT SCHEDULE FOR SWITCH RATING AND FUSE SIZES (IF REQUIRED). ,rli,rrli SINGLE-PHASE MOTOR. "M" INDICATES MOTOR HORSEPOWER OR AS NOTED. "F" INDICATES FRACTIONAL HORSEPOWER. THREE-PHASE MOTOR. "M" INDICATES MOTOR HORSEPOWER OR AS NOTED. "F" INDICATES FRACTIONAL HORSEPOWER. ® DUAL CHANNEL POWER/COMMUNICATIONS SERVICE POLE. WALL MOUNTED COMBINATION VOICE/DATA OUTLET, 18" ABOVE FINISHED FLOOR, 'c' INDICATES COUNTER TOP HEIGHT OR 44" ABOVE FINISHED FLOOR. PROVIDE 1" CONDUIT WITH PULLSTRING TO ABOVE ACCESSIBLE CEILING OR TO TELEPHONE TERMINAL BACKBOARD. WALL MOUNTED COMBINATION TELEPHONE OUTLET, 18" ABOVE FINISHED I FLOOR, 'c' INDICATES COUNTER TOP HEIGHT OR 44" ABOVE FINISHED FLOOR. PROVIDE 1" CONDUIT WITH PULLSTRING TO ABOVE ACCESSIBLE CEILING OR TO TELEPHONE TERMINAL BACKBOARD. WALL MOUNTED COMBINATION DATA OUTLET, 18" ABOVE FINISHED FLOOR, 'c' p INDICATES COUNTER TOP HEIGHT OR 44" ABOVE FINISHED FLOOR. PROVIDE 1" i CONDUIT WITH PULLSTRING TO ABOVE ACCESSIBLE CEILING OR TO TELEPHONE TERMINAL BACKBOARD. VOICE/DATA, IN FLUSH FLOOR BOX, PROVIDE 1" CONDUIT MINIMUM UNO IN ' SLAB OR UNDERSLAB TO NEAREST POINT OF ACCESS, AS SHOWN ON DRAWINGS. COMBINATION POWER, VOICE, DATA, IN FLUSH FLOOR BOX, PROVIDE 1" V CONDUIT MINIMUM (UNO) FOR VOICE AND DATA. PROVIDE 3/4" CONDUIT P MINIMUM (UNO) FOR POWER. ROUTE CONDUITS IN SLAB OR UNDERSLAB TO NEAREST POINT OF ACCESS. "P" INDICATES POKE -THROUGH TYPE BOX. TTB TELEPHONE/COMMUNICATIONS TERMINAL BACK BOARD (TTB). ® 4' X 8' X 3/4" FIRE RATED PLYWOOD. I-J-3 COMMUNICATIONS CABLE/LADDER TRAY. SIZE AS INDICATED ON THE DRAWINGS. ® CEILING MOUNTED WIRELESS ACCESS POINT. $X WALL SWITCH, 48" ABOVE FINISHED FLOOR, UNO. (X DENOTES TYPE BELOW) 3 - THREE WAY TOGGLE 4 - FOUR WAY TOGGLE d - DIMMER os - OCCUPANCY SENSOR °% - DIMMING OCCUPANCY SENSOR m - MOTOR RATED k - KEYED t - TIMER OS / OS WALL/CEILING-MOUNTED OCCUPANCY SENSOR, DUAL TECHNOLOGY. WHERE WALL MOUNTED, WALL MOUNT AT 6" BELOW CEILING SURFACE, UNO. PC /© WALL/CEILING-MOUNTED PHOTOELECTRIC CONTROL SENSOR. WHERE WALL MOUNTED, WALL MOUNT AS NOTED ON THE DRAWINGS. EXIT SIGN, ARROWS AS REQUIRED. (PROVIDE UN -SWITCHED HOT WIRE) COMBINATION EXIT SIGN AND EMERGENCY LIGHT, ARROWS AS REQUIRED. (PROVIDE UN -SWITCHED HOT WIRE) 5�=g BATTERY POWER EMERGENCY LIGHT (PROVIDE UN -SWITCHED HOT WIRE) 4 OUTDOOR EMERGENCY EGRESS LIGHT GENERAL ELECTRICAL NOTES: 1. ALL WORK SHALL COMPLY WITH ALL LOCAL BUILDING CODES, LAWS, REGULATIONS, ORDINANCES AND NATIONAL ELECTRICAL CODE. 2. THE ELECTRICAL WORK SHALL CONSIST OF ALL LABOR AND MATERIAL TO COMPLETELY INSTALL ALL ELECTRICAL WORKS AS SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL CONFIRM EXISTING CONDITIONS PRIOR TO PROCEEDING WITH WORK. ANY DISCREPANCIES (PANEL BRANCH CIRCUITS, EQUIPMENT RATINGS, ETC.) SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. COORDINATE LOCATION OF LIGHT FIXTURES IN AREAS OF MECHANICAL DUCTWORK AND PIPING WITH MECHANICAL CONTRACTOR. RELOCATE LIGHT FIXTURES, WIRING AND CONDUIT IF NECESSARY AS DIRECTED BY THE ARCHITECT/ENGINEER. 4. ALL WORK ASSOCIATED WITH THE SCOPE OF THIS PROJECT INCLUDING EQUIPMENT, ACCESSORIES, DEVICES, SYSTEMS, ETC. SHALL BE COVERED BY A ONE YEAR GUARANTEE WHICH SHALL START AT THE TIME OF FINAL ACCEPTANCE BY THE OWNER. ANY DEFECTS IN PRODUCTS, INSTALLATION, WORKMANSHIP SHALL BE CORRECTED AT NO ADDITIONAL CHARGE AND SHALL INCLUDE ANY NECESSARY REPAIRS TO WALLS, FLOORS, MILLWORK, ETC. WHICH SHALL BE REPAIRED BACK TO NEW AND FINISHED CONDITION. 5. THE CONTRACTOR SHALL KEEP A RECORD OF THE CHANGES WHICH ARE IN CONFLICT WITH THESE DRAWINGS AND SPECIFICATIONS. AT THE COMPLETION OF THIS WORK THE CONTRACTOR SHALL SUBMIT "RECORD" PRINTS TO THE OWNER. 6. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY SHOW THE EXACT ROUTING OR DETAILED FITTINGS. ALL WORK SHALL BE INSTALLED AS A COMPLETE SYSTEM WITH NECESSARY COMPONENTS, FITTINGS, STRAPS, ETC. ALL JUNCTION BOXES AND COMPONENTS SHALL BE INSTALLED SO THAT THEY ARE ACCESSIBLE. 7. REFER TO THE ENTIRE CONTRACTED DRAWING SET AND SPECIFICATIONS FOR GUIDANCE ON DIMENSIONS, CEILING HEIGHTS, DOOR SWINGS, ROOM FINISHES, STRUCTURAL DETAILS, LOCATIONS OF DUCTWORK, PIPING AND STRUCTURAL MEMBERS. INSTALL THE ELECTRICAL SYSTEMS SO AS NOT TO INTERFERE WITH THE INSTALLATION OR FUNCTION OF ANOTHER DISCIPLINES WORK. 8. PROVIDE PROPER DIMENSIONS NOT SHOWN PRIOR TO EQUIPMENT FABRICATION. ALL COST FOR MODIFICATIONS OF NEW CONSTRUCTION DUE TO LACK OF CONFIRMATION OF DIMENSIONS BY FIELD MEASUREMENT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 9. ALL CONDUIT MUST BE CONCEALED ABOVE THE CEILING OR IN THE WALLS UNLESS OTHERWISE NOTED. 10. COORDINATE RECEPTACLE NEMA TYPE AND VOLTAGE WITH ALL EQUIPMENT. 11. THE CONTRACTOR SHALL INSTALL ALL WORK IN A NEAT AND WORKMANLIKE MANNER AND ACCORDING TO GENERALLY ACCEPTED PRACTICES OF FIRST CLASS WORKMANSHIP. 12. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL ELECTRICAL EQUIPMENT FROM FOREIGN MATERIAL DURING CONSTRUCTION (PAINT, SPACKLE, ETC...) 13. PROVIDE A NEW TYPED DIRECTORY FOR ALL PANELBOARDS CLEARLY DESCRIBING THE LOCATION OF AND TYPE OF LOAD BEING SERVICED FOR ALL CIRCUITS. CORRECTLY LABEL ALL CIRCUITS, SPACES AND SPARES. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOARDS AND DISCONNECT SWITCHES, WHITE LETTERS ON BLACK BACKGROUND. 14. ALL RECESSED LIGHTING FIXTURES SHALL BE FASTENED TO STRUCTURE OR GRID PER N.E.C. 410. 15. ANY CONDUIT, BUSWAY, CABLE TRAY, SLEEVES, ETC. THAT PENETRATE RATED WALLS, CEILINGS AND FLOORS SHALL BE FIRE STOPPED PER CODE. 16. MOUNTING HEIGHTS FOR DEVICES ARE TO BE MEASURED TO THE DEVICE CENTERLINE. 17. ALL BRANCH CIRCUITS SHALL BE WIRED 2-#12, 1-#12G MINIMUM, UNLESS OTHERWISE NOTED ON THE PLANS. ALL HOMERUNS SHALL BE A MINIMUM 3/4" CONDUIT. 18. PROVIDE A SEPARATE GREEN, INSULATED, #12AWG EQUIPMENT GROUNDING CONDUCTOR ROUTED WITH THE BRANCH CIRCUIT HOMERUN CONDUCTORS. PROVIDE GROUND THROUGH ENTIRE CONDUIT RUN TO THE LAST DEVICE. ALL EQUIPMENT SHALL BE GROUNDED AT THE PANEL WHICH FEEDS THE EQUIPMENT. PROVIDE GROUNDING PER NEC 250. 19. ALL SWITCHES FOR LIGHTS, FANS, ETC., WHICH ARE SHOWN TO BE MOUNTED IN THE SAME GENERAL AREA, SHALL SHARE A MULTI -GANG COVER PLATE AS REQUIRED. 20. ARMORED CABLE MAY BE USED IN WALLS AND MILLWORK ONLY AND MUST BE MC TYPE (WITH GROUND). ALL CONDUIT TO AND ABOVE THE PLENUM SHALL BE EMT. ALL HOMERUNS SHALL BE IN CONDUIT RUN FROM THE FIRST DEVICE OR LIGHT FIXTURE TO THE PANEL. ALL WIRING SHALL BE INSTALLED IN GALVANIZED RIGID CONDUIT, INTERMEDIATE METAL CONDUIT, OR EMT. EMT SHALL NOT BE USED IN OR UNDER CONCRETE SLABS, OR IN MASONRY WALLS. USE SCHEDULE 40 PVC OUTDOORS WHERE NOT SUBJECT TO PHYSICAL DAMAGE OR BELOW FLOOR SLAB. TYPE MC AND AC CABLE MAY BE USED WHERE PERMISSIBLE BY NEC. TYPE NM CABLE MAY BE USED IN TYPE III, IV, V CONSTRUCTION AS ALLOWED BY THE NEC. 21. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF OUTLETS, LIGHT FIXTURES, AND PARTITIONS. FINISHES FOR DEVICES AND COVERPLATES SHALL BE AS SELECTED BY ARCHITECT. 22. PROVIDE A 2-GANG OUTLET BOX AND 1" CONDUIT WITH PULL STRING TO ABOVE ACCESSIBLE CEILING FOR ALL NEW DATA, TELEPHONE AND CABLE OUTLETS. COORDINATE PLASTER RING SIZE WITH TENANT AND CABLE VENDOR. 23. ROUTE (1) 1" CONDUIT WITH PULL STRING FROM EACH FLOOR COMMUNICATION OUTLET TO NEAREST FULL HEIGHT WALL AND STUB -UP TO NEAREST ACCESSIBLE CEILING. COORDINATE WITH CABLE VENDOR. 24. LIGHT FIXTURES SHALL BE AS SCHEDULED, WITH ONLY PRE -APPROVED EQUAL FIXTURES ACCEPTABLE. 25. ALL CONDUCTORS SHALL BE COPPER. CONDUCTORS FOR SIZES NO. 10 AND SMALLER SHALL BE TYPE "THWN" OR "THHN/THWN". CONDUCTORS FOR SIZES NO. 8 AND LARGER SHALL BE TYPE "XHHW". SOLID CONDUCTORS TERMINATING IN A BREAKER OR DEVICE SHALL BE WIRE SIZE NO. 12 AWG, MINIMUM AND WIRE SIZE SHALL BE NO. 10 AWG MAXIMUM. WIRE SIZES NO. 8 AWG AND LARGER ARE TO STRANDED. 26. ALL BOXES SHALL BE PRESSED STEEL, SINGLE PIECE (NON-GANGABLE) TYPE. 27. ALL COVER PLATE AND DEVICE FINISHES SHALL BE SELECTED BY ARCHITECT. 28. ALL COVER PLATES FOR DEVICES AND JUNCTION BOXES SHALL HAVE CIRCUIT NUMBERS LABELED WITH INDELIBLE INK MARKER. DEVICE COVERS SHALL BE LABELED ON THE BACK, JUNCTION BOX COVERS SHALL BE LABELED ON THE FRONT. 29. RECEPTACLES SHALL BE 120 VOLT, 20A, WITH PARTS NUMBERS AS LISTED BY HUBBELL OR EQUAL BY ARROWHART, P&S, OR LEVITON. COLOR SHALL BE AS SELECTED BY THE ARCHITECT. SINGLE RECEPTACLE #HBL5361X DUPLEX RECEPTACLE #HBL5352X GFCI RECEPTACLE #GF5352X 30. SWITCHES SHALL BE 120/277V. 20A, WITH PARTS NUMBERS AS LISTED BY HUBBELL OR EQUAL BY ARROWHART, P&S, OR EAGLE. COLOR SHALL BE AS SELECTED BY THE ARCHITECT. SINGLE POLE #HBL1221 THREE WAY #HBL1223 FOUR WAY #HBL1224 (ADD "L" SUFFIX FOR KEYED LOCKING TYPE) 31. PANELBOARDS, MOTOR STARTERS, SAFETY SWITCHES (HEAVY DUTY), ETC. SHALL BE AS MANUFACTURED BY GENERAL ELECTRIC, SQUARE D, SIEMENS, OR CUTLER HAMMER. ALL BREAKERS SHALL BE "BOLT -ON" TYPE. 32. FOR EQUIPMENT THAT IS TO BE WIRED BY ELECTRICAL CONTRACTOR AND FURNISHED BY OTHERS. ELECTRICAL CONTRACTOR SHALL REVIEW ALL SPECIFICATION SECTIONS, EQUIPMENT SCHEDULES, OR/OR DETAILS THROUGHOUT DOCUMENTS THAT PERTAIN TO THIS EQUIPMENT AND INCLUDE ALL WIRING AND DEVICES REFERENCED IN THEIR BIDS. ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION OF THIS EQUIPMENT WITH RESPECTIVE CONTRACTOR PRIOR TO ROUGH -IN. 33. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A GYPBOARD BOX AROUND ANY RECESSED FIXTURE THAT PENETRATES THE MEMBRANE OF A RATED ASSEMBLY IN ORDER TO MAINTAIN THE RATING. 34. PROVIDE A PULLSTRING IN ALL EMPTY CONDUITS. 35. ALL MATERIAL, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE NEW AND SHALL CONFORM TO THE STANDARDS OF THE UNDERWRITER'S LABORATORIES, INC., AND THE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA). 36. ELECTRICAL CONTRACTOR SHALL MAKE ALL ELECTRICAL POWER CONNECTIONS TO HVAC, PLUMBING AND OTHER EQUIPMENT AS REQUIRED. 37. A COMPLETE GROUNDING SYSTEM SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF THE NEC, AND AS SHOWN ON THE DRAWINGS. 38. ALL CUTTING AND PATCHING OF WALLS AND FLOORS FOR ELECTRICAL EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 39. FUSES 0-600 AMPS SHALL BE UL CLASS "RK-1" LOW PEAK DUAL ELEMENT TIME DELAY WITH 200,000 AMPERE INTERRUPTING RATING AS MANUFACTURED BY BUSSMAN, UNLESS OTHERWISE NOTED. 40. ALL TERMINALS/LUGS SHALL BE 75' RATED. ALL TERMINALS, SPLICING CONNECTORS, LUGS, ETC SHALL BE IDENTIFIED FOR USE WITH THE MATERIALS (CU/AL) OF THE CONDUCTOR AND SHALL BE PROPERLY INSTALLED. 41. VERIFY ALL REQUIREMENTS AND COORDINATE EXACT LOCATION OF INCOMING ELECTRICAL SERVICE WITH LOCAL UTILITY COMPANY PRIOR TO PROJECT START-UP. NOTIFY ENGINEER OF ANY CHANGES AS MAY BE REQUIRED. 42. PENETRATIONS OF REQUIRED SMOKE PARTITIONS SHALL BE SEALED USING METHODS APPROVED UNDER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THIS SMOKE STOPPING IS ACCOMPLISHED. 43. WHERE PENETRATIONS ARE MADE THROUGH A REQUIRED FIRE -RESISTIVE WALL, FLOOR, OR PARTITION FOR THE PURPOSE OF RUNNING RACEWAY CARRYING ELECTRICAL, TELEPHONE, TELEVISION, OR LOCAL COMMUNICATION AND/OR SIGNALING CIRCUITS, THE OPENING AROUND THE RACEWAY SHALL BE FIRE STOPPED PER THE STATE BUILDING CODE. COORDINATION WITH THE GENERAL CONTRACTOR SHALL BE MAINTAINED TO INSURE THAT THIS FIRE STOPPING IS ACCOMPLISHED. USE APPROVED U.L. OR EQUIVALENT ASSEMBLIES. 44. IN REQUIRED FIRE RATED WALL AND PARTITIONS, OPENINGS FOR INSTALLATION OF BOXES THAT ARE GREATER THAN 16 SQUARE INCHES SHALL BE PROTECTED AS REQUIRED BY UL. COORDINATE CLOSELY WITH THE GENERAL CONTRACTOR TO INSURE THAT THE INTEGRITY OF THE UL RATING IS MAINTAINED. 45. COORDINATE WITH THE CABLE TV AND TELEPHONE UTILITIES AS REQUIRED FOR SERVICE ENTRANCE REQUIREMENTS. INSTALLATION MUST COMPLY WITH THEIR RESPECTIVE REGULATIONS AND REQUIREMENTS. 46. ALL EXTERIOR FIXTURES AND DEVICES SHALL BE RATED FOR OPERATION AT 0° F AND SHALL BE DAMP OR WET LISTED AS REQUIRED. 47. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL ELECTRICAL EQUIPMENT, DEVICES, ETC. IN ACCORDANCE WITH LOCAL SEISMIC CODE REQUIREMENTS. PROVIDE SEISMIC RESTRAINTS, ACCESSORIES AND INSTALLATION DETAIL DETAIL AS REQUIRED. 48. VERIFY THAT ALL CONDUIT PENETRATIONS OF THE WALK-IN REFRIGERATOR AND FREEZER ARE SEALED PER 300.7(A). 49. WHERE A HOME RUN IS SHOWN THE CIRCUIT SHALL BE INSTALLED IN A DEDICATED CONDUIT, DO NOT COMBINE WITH OTHER CIRCUITS. WHERE A CIRCUIT HOMERUN IS NOT SHOWN, THE CONTRACTOR SHALL COMBINE CIRCUITS AS FOLLOWS: A MAXIMUM OF THREE 20A BRANCH CIRCUITS MAY BE COMBINED IN A COMMON HOMERUN SHARING A COMMON NEUTRAL OR WITH SEPARATE NEUTRALS FOR A MAXIMUM TOTAL OF SIX CURRENT CARRYING CONDUCTORS. ALL BRANCH CIRCUITS LARGER THAN 20A SHALL BE SEPARATELY HOMERUN TO THE PANEL. SEPARATE PERMIT REQUIRED FOR ELELCTRICAL f►.t►AWIl►&OP- '7 HWAIYANG A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS 1 MISSOURI 1 63131 hwai@hwaiyangarchitects.com TLCENGINEERING SOLUTIONS® 4360 Chamblee Dunwoody Rd ©Copyright 2021 Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 'Fy nr THOMAS G. WHITE ,s ._ 119671• O � � U Cz c,0 O Cz cz � }' G� CD >t �> O C3CD L 7 RECEIVED 7/18/2 Z CITY OF FEDRMhL WAY COMMUNITY DEPtiCLOPMENT o y Z O U N w O w 0 CD 0 L L cD W z o CIO y o PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: NM CHECKED BY: TW SHEET #: EOOO ELECTRICAL GENERAL NOTES �PLAN - 1 /4" = V-0" ELECTRICAL f►. AMIlIl►.i'Z.3'l UNFR& NOTFS: APPLY TO THIS SHEET ONLY DASHED LINES REPRESENT WALLS/EQUIPMENT THAT ARE TO BE DEMOLISHED. SOLID, SHADED LINES ARE EXISTING TO REMAIN. COORDINATE WITH ARCHITECTURAL PLANS FOR DEMOLITION WORK. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS TO BE DEMOLISHED SHALL BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY OTHER CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER TRADES FOR EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING, AND SPECIAL SYSTEMS. REFER ALL QUESTIONS OF APPLICABILITY TO THE ARCHITECT PRIOR TO BID FOR CLARIFICATION. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE SCOPE OF THE DEMOLITION WORK AND THAT NOT ALL ITEMS OF ELECTRICAL DEMOLITION ARE NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY AND FIELD DETERMINE THE SCOPE OF THE DEMOLITION WORK PRIOR TO BID. REFER ALL QUESTIONS TO THE PROJECT MANAGER PRIOR TO BID FOR CLARIFICATION. 4. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF OTHER TRADES. COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION ACTIVITIES. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO OTHER AREAS OF THE FACILITY THAT ARE TO REMAIN IN OPERATION, THEN RACEWAY AND WIRING SHALL BE INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY CONNECTIONS AS REQUIRED. ELECTRICAL CIRCUITS THAT ARE TO BE DEMOLISHED SHALL BE REMOVED FROM THE AREA OF WORK. CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE OVERCURRENT PROTECTIVE DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND ALL SHALL BE CUT OF CHISELED AT LEAST 2" INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. EXISTING DEVICE OR JUNCTION BOXES THAT MUST REMAIN IN EXISTING WALLS OR CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS,) SHALL BE FITTED WITH BLANK COVER PLATES. ■LYM Kim, , 1!' A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS 1 MISSOURI 1 63131 hwai@hwaiyangarchitects.com TLCENGINEERING SOLUTIONS® 4360 Chamblee Dunwoody Rd ©Copyright 2021 Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 THOMAS G. WHITE A.:. 119671• O M a M CZ co F- O cz CZ C3i }' cn CD >''> OCD L U) RECEIVED 7/18/2 Z CITY OF FEDAML WAY COMMUNITY DERLOPMENT z 0 i= U N w 0 w a 0 Y Q H Z 'O V O U- W C4 C4 PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: NM CHECKED BY: TW SHEET #: El 0 ■ EXISTING PANEL DIRECTORIES SHALL BE UPDATED TO ACCURATELY REFLECT CONDITIONS AFTER WORK IS COMPLETE. UNUSED CIRCUIT BREAKERS SHALL BE LABELED IN PENCIL AS "SPARE." ELECTRICAL DEMOLITION PLAN PHASE 1 FLOOR PLAN - ELECTRICAL NEW WORK SCALE:1/4" = 1'-0" LIGHT FIXTURE SCHEDULE: A 1' X 4' LED SURFACE: LITHONIA LIGHTING LB432 (WITH EMERGENCY BATTERY BACK—UP, AE) GENERAL NOTES: APPLY TO THIS SHEET ONLY 1. ALL RECEPTACLES SHALL BE TAMPER —RESISTANT (TRR) TYPE. 2. RECEPTACLES SHALL BE FED FROM EXISTING BRANCH CIRCUITS. BRANCH CIRCUITS SHALL BE AS SHOWN BUT FINAL BRANCH CIRCUITS SHALL BE AT THE DISCRETION OF THE INSTALLING CONTRACTOR TO UTILIZE EXISTING WIRING AND CONDUIT. NO MORE THAN SIX (6) RECEPTACLES PER BRANCH CIRCUIT, 3. LIGHTS SHALL BE CIRCUITED FROM EXISTING LIGHTING BRANCH CIRCUITS. HALL ALLY PER 2 KEY NOTES: APPLY THIS SHEET ONLY O1 RESTROOM TO HAVE NEW EXHAUST FAN EF—A. PROVIDE RATED SNAP SWITCH ADJACENT TO FAN AND PROVIDE ON/OFF CONTROL AT WALL ADJACENT TO LIGHT FIXTURE SWITCH. FAN TO BE CONNECTED TO BRANCH CIRCUIT FEEDING LIGHTS. O2 NEW W/D. PROVIDE 30A/2P BREAKER FOR DRYER. O3 REINSTALL THE EXISTING LIGHT FIXTURES IN THE RENOVATED CEILING AND CONNECT AS SHOWN. 22-102989 HWAIYANG A R C H IT E C T S 2711 COVINGTON PLACE ESTATES ST. LOUIS 1 MISSOURI 1 63131 hwai@hwaiyangarchitects.com ATLOENGINEERING SOLUTIONS® 4360 Chamblee Dunwoody Rd ©Copyright 2021 Suite 210 Atlanta, GA 30341 P 770.451.6757 www.tic-engineers.com TLC NO: 822142 O c �= 0 F— cz Cz c3) �+ .> CCD i RECEIVED 7/18/2 Z CITY OF FEDRMhL WAY COMMUNITY DFRLOPMENT o y ~ Z U o N w o C/j w o CD 0 � cD z o W o< CIO y PROJECT #: 21-916 FILE NAME: 21-916CD DRAWN BY: NM CHECKED BY: TW SHEET #: E200 ELECTRICAL NEW WORK FLOOR PLANS