Loading...
22-103398-Plan Set-7-30-2222-103398 BARNES RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 PLAN SET 27 July 2022 RECEIVED Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Bureau Braun LLC 100 Ward Street, Ste. 203, Seattle, Washington 98109 GENERAL NOTES PROJECT TEAM DRAWING INDEX 22-10 398 BARNES ARCHITECTURAL 1. CONTRACTOR TO PHYSICALLY INSPECT SITE PRIOR TO COMMENCING ANY WORK. REPORT ANY OWNER DISCREPANCY TO ARCHITECT. CONTRACTOR TO REVIEW CONSTRUCTION DOCUMENTS PRIOR TO RESIDENCE A0.01 DRW INDEX & PROJECT INFO CONSTRUCTION. ANY QUESTIONS SHOULD BE DIRECTED TO OWNER AND/OR ARCHITECT RONALD & MARY BARNES CONTRACTOR TO CROSS-REFERENCE WITH AHJ-APPROVED PLANS FOR ANY CHANGES AND/OR ANY 1298 SW 301 ST STREET REMODEL A0.02 LEGENDS ADDITIONAL REQUIREMENTS BY AHJ. FEDERAL WAY, WA 98023 A0.05 ENERGY FORMS 2. ALL INFORMATION CONTAINED IN THESE DOCUMENTS REPRESENTS A "BASIC LIMITED CONTACT: RON BARNES EMAIL: RON.BARN ES@FASTWALLS.COM AO. 10 SITE PLAN 1298 SW 301 ST STREET A0.90 EX FOUNDATION PLAN ARCHITECTURAL SERVICE" THAT REQUIRES THE CONTRACTOR TO BE KNOWLEDGEABLE AND EXPERIENCE WITH ALL ASPECTS OF CONSTRUCTION INCLUDING ALL BUILDING CODES AND TEL: 206.688.6698 FEDERAL WAY, WA 98023 A1.00 EX PLAN - BASEMENT REGULATIONS. A1.01 PPSD PLAN - BASEMENT ARCHITECT A1.10 EX PLAN - MAIN FLOOR Architect: 3. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL ORDINANCES, AND SHALL BE DONE TO THE BUREAU BRAUN LLC A1.11 EX FRAMING PLAN -MAIN FLOOR HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMEN OF THE RESPECTIVE TRADES. 100 WARD STREET, STE. 203 SEATTLE, WA 98109 A1.12 PPSD PLAN -MAIN FLOOR B U R E A U 4. THE CONTRACTOR SHALL CARRY ALL INSURANCE REQUIRED BY LAW. A1.23 EX CEILING FRAMING PLAN 5. SAFETY, CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION COMPLIANCE WITH LOCAL CONTACT: BEN WATERS A5.00 BUILDING SECTIONL: B R A U N BE L: BE EMAIN_WATERS@BUREAUBRAUN.COM STATE, FEDERAL REGULATIONS REGARDING SAFETY ON SITE SHALL BE THE CONTRACTORS TEL: 5.0108 RESPONSIBILITY. BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 6. NO DEVIATIONS FROM THESE DOCUMENTS SHALL BE MADE WITHOUT WRITTEN APPROVAL FROM ARCHITECT. ANY CHANGES CAN AFFECT THE STRUCTURAL INTEGRITY AND CODE -RELATED ISSUES Consultants: OF STRUCTURE. 7. ALL INFORMATION CONTAINED IN THESE DOCUMENTS IS FOR THE PURPOSE OF CONSTRUCTION PERMIT ACQUISITION AND CONSTRUCTION ONLY. THE INFORMATION PROVIDED IS NOT INTENDED FOR ANY OTHER PURPOSE AND NO OTHER USE IS INTENDED OR IMPLIED, E.G. PLAN INFORMATION IS NOT INTENDED TO BE USED AS A BASE FOR SALE OR TRANSFER OF REAL ESTATE. 8. "BASIC LIMITED SERVICE" PROVIDES THE LOWEST LEVEL OF ARCHITECTURAL SERVICE WITH NO DRAWINGS AND SPECIFICATIONS PROVIDED OTHER THAN REQUIRED FOR PERMITS. Issued For: No.: Description: Date: 9. UNLESS OTHERWISE SPECIFIED, ELECTRICAL MECHANICAL, ETC. IS BIDDER DESIGN OWNER AND/OR AGENT (CONTRACTOR) IS RESPONSIBLE FOR ALL WORK DONE SITE (FIELD) AS TO PROPER PLAN SET 2022-07-27 INSTALLATION, ETC. 10. THE ARCHITECT MAY ASSIST IN COORDINATION WITH CONSULTANTS, ETC. (SUCH AS SOILS, STRUCTURAL, CIVIL ENGINEERS, ETC.) BUT UNDER THE TERMS OF BASIC LIMITED SERVICE RECEIVES NO COMPENSATION FOR AND ASSUMES NO RESPONSIBILITY OR LIABILITY FOR THE AREA OF THEIR (CONSULTANTS) WORK AND EXPERTISE. ACCEPTANCE OF THESE PLANS FOR CONSTRUCTION CONSTITUTES AN UNDERSTANDING OF ABOVE MENTIONED ITEMS AND BASIC LIMITED ARCHITECTURAL SERVICE AS DESCRIBED HEREIN AND IN AGREEMENT BETWEEN OWNER/ARCHITECT. VINCINITY MAP PROJECT CODE SUMMARY APPLICABLE CODES: BUILDING: 2018 WASHINGTON STATE RESIDENTIAL CODE (IRC) SW30 0thp1 PLUMBING: 2018 UNIFORM PLUMBING CODE (UPC) SW300thSn MECHANICAL: 2018 WASHINGTON STATE MECHANICAL CODE (INC) s� N ELECTRICAL: 2017 WA CITIES ELECTRICAL CODE (2017 WCEC W/ 2020 NEC UPDATES) FIRE: 2018 WASHINGTON STATE FIRE CODE (IFC) t 1298 SW 301ST ST ENERGY: 2018 WASHINGTON STATE ENERGY CODE - RESIDENTIAL (WSEC-R) SW 301st St EXISTING BUILDING INFORMATION: n `m PARCEL: 515320-0260 5 N ADDRESS: 1298 SW 301 ST ST, FEDERAL WAY, WA 98023 N EX TYPE OF CONSTRUCTION: TYPE V-B Seal &Signature: BUILDING HEIGHT ABOVE GRADE: 1 STORY 1 V 3 v ZONING: RS 15.0 22008388 REGISTERED ¢' N SW3°4ihSt SW304thS[ SW304thSt swso4thst LEGAL DESCRIPTION: MARINE VIEW ESTATES ADD PLAT BLOCK 3 PLAT LOT 12 ARCHITECT N s OCCUPANCIES AND USES: R-3 "SINGLE FAMILY RESIDENCE" BENJAMIN WATERS SQUARE FOOTAGE: EX SFR (AGLA): 1,879 SF STATE OF WASHINGTON NORTH EX FIN BSMT: 1,172 SF EX ATT GARAGE: 707 SF AREA OF WORK: PARTIAL INTERIOR REMODEL OF BASEMENT & MAIN LEVEL Sheet Name: AHJ: FEDERAL WAY DRW INDEX & PROJECT INFO SCOPE OF WORK INTERIOR REMODEL (NO STRUCTURAL SCOPE) AT EXISTING SINGLE FAMILY RESIDENCE LOCATED 1298 SW 301 ST ST, FEDERAL WAY, WA 98023 PER DRAWINGS. Project No.: Sheet No.: 21.01.38 Drawn By: Author Checked By: Checker AO . O 1 Scale: Plan Review Stamp: Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT a 0 m Lo v v N N O N f` N ABBREVIATIONS SYMBOL LEGEND 22-10 398 A E i P T BARNES AC Architectural Concrete EA Each IC Intercom PA Public Address T Tread DRAWING TITLE AV Audio Visual EC Exposed Construction ID Inside Diameter PAR Parallel T&G Tongue and Groove TITLE DRAWING NAME EARTH / COMPACT FILL RESIDENCE ACST Acoustical EEWS Emergency Eye Wash Shower INCL Include(d) / Inclusive / Including PART Partial TO Top of DRAWING NUMBER ACT Acoustical Ceiling Tile EFTR Existing Finish to Remain INFO Information PAV Pavers TA Toilet Accessory(ies) SCALE: 1/4" 1'-0"ocy—t DRAWING SCALE REMODEL AD Area Drain EIFS Exterior Insulated Finish System INS Insulation / Insulate(d) PB Particle Board TB Tie Back POROUS FILL / GRAVEL - COARSE ADDL Additional EJ Expansion Joint INT Interior PC Precast Concrete TBD To Be Determined ADJ Adjacent EL Elevation (Grade) INV Invert PD Planter Drain TC Traffic Coating ROOM TAG 1298 SW 301 ST STREET ADR Access Door ELAST Elastomeric PERF Perforated TD Trench Drain ROOM NAME ROOM NAME INDICATOR POROUS FILL / GRAVEL - FINE AF Access Floor ELEC Iectric(al) J PERP Perpendicular TEL Telephone 101 ROOM NUMBER FEDERAL WAY, WA 98023 AFF Above Finished Floor ELEC CL Electric Closet JC Janitor Closet PLA Plaster TEMP Temperature 150 SF AREA AGGR Aggregate ELEV Elevator JF Joint Filler PLAM Plastic Laminate TER Terrazzo CONCRETE / PRECAST CONCRETE AHU Air Handling Unit ELEV Elevation (Bldg) JG Joint Gasket PLBG Plumbing THK Thick(ness) Architect: ALT Alternate EM Entrance Mat JT Joint PLYWD Plywood THRES Threshold ROOM TAG ALUM Aluminum EMER Emergency PNEU Pneumatic TOC Top of Curb ROOM NAME ROOM NAME INDICATOR -_ _ - - _ = SAND / MORTAR / PLASTER / CUT STONE I I R E A ANOD Anodized ENCL Enclosure / Enclose(d) K POL Polished TOPO Topography Ma 101 ROOM NUMBER U p B U APPROX Approximate(ly) ENTR Entrance KID Knockdown PR Pair TRANS Transom B R A U N APT Apartment EOS Edge of Slab KIT Kitchen PREFAB Prefabricate(d) TV Television CONCRETE MASONRY UNIT ARCH Architect(ural) EQ Equal KO Knockout PROJ Project(s) TYP Typical SIM DETAIL INDICATOR AUTO Automatic EQUIP Equipment KPL Kickplate PROP Property 01 DETAIL IDENTIFICATION BUREAU BRAUN, LLC AUX Auxiliary ESCAL Escalator PSF Pounds per Square Foot U A3 01 DRAWING NUMBER ALUMINUM 100 WARD ST APT 203, SEATTLE, WA 98109 AVG Average ETR Existing to Remain L PSI Pounds per Square Inch UC Undercut EW Each Way L Angle PT Paint(ed) UNFIN Unfinished Consultants: B EWC Electric Water Cooler LAB Laboratory PTN Partition UON Unless Otherwise Noted SECTION INDICATOR STEEL OTHER METALS BO Bottom of EXH Exhaust LAM Laminate(d) PVC Polyvinyl Chloride UPS Uninterrupted Power Supply 01 SECTION IDENTIFICATION BD Board EXIST Existing LAV Lavatory PVG Paving A3 01 DRAWING NUMBER BEV Beveled EXP Exposed LBS Pound(s) PWR Power V PLYWOOD - LARGE SCALE BG Bumper Guard EXPN Expansion LIDLinear Diffuser VAC Vacuum LEVEL NAME BLDG Building EXT Exterior LEED Leadership in Energy and Q VERT Vertical EL: ELEVATION ELEVATION DATUM; REFERENCE BLKG Block(ing) Environmental Design QT Quarry Tile VEST Vestibule POINT; WORK POINT; DIMENSION FINISH WOOD FOR ARCH WOODWORK BM Beam F LH Left Hand QTY Quantity VIF Verify in Field POINT; START POINT BMK Benchmark F Fahrenheit LIN Linear VNR Veneer BOC Bottom of Curb FA Fire Alarm LONG Longitudinal R VOL Volume COLUMN LINE INDICATOR BATT / LOOSE FILL INSULATION Issued For: BR Bedroom FAAP Fire Alarm Annunciator Panel LP Low Point R Riser No.: Description: Date: BRK Brick FAB Fabric LR Living Room RA Return Air W TT77 i PLAN SET 2022-07-27 BRZ Bronze FD Floor Drain LTG Lighting RAID Radius W/ With 101 DOOR NUMBER RIGID PLASTIC INSULATION BSMT Basement FDTN Foundation LVR Louver(ed) RB Resilient Base W/0 Without BS Brass FE Fire Extinguisher RC Reinforced Concrete WB Wood Base BTU British Thermal Unit(s) FEC Fire Extinguisher Cabinet M RD Roof Drain WCV Wall Coverings REVISION TAG NON FOAM INSULATION BOARD FF Finish Floor MACH Machine RECPT Receptacle WD Wood C FG Finish Grade MAINT Maintain / Maintenance RECT Rectangle WDF Wood Door and Frame CAP Capacity FH Fire Hydrant MATL Material RE Refer to WH Wall Hydrant NORTH SYMBOL SEMI -RIGID MINERAL FIBER INSULATION CB Catch Basin FHC Fire Hose Cabinet MAX Maximum REF Reference WI Wrought Iron CCTV Closed Circuit Television FHR Fire Hose Rack (Reel) MB Metal Base REFR Refrigerator WL Wall CFMF Cold Formed Metal Framing FIN Finish(ed) MECH Mechanical REG Register WP Work Point 01 / A101 VIEW / REFERENCE LATH AND PLASTER CFM Cubic Feet Per Minute FIN FL Finish Floor MED Medium REINF Reinforce(d, -ing, -ment) WPM Waterproofing Membrane CG Corner Guard(s) FIN GR Finish Grade MEZZ Mezzanine REQD Required WPS Waterproofing System Cl Cast Iron FLEX Flexible MFR Manufacturer REV Revised / Revision WR Weather Resistant ELEVATION INDICATOR - -- GYPSUM BOARD CJ Control Joint FL Flashing MH Manhole RF Resilient Flooring WRB Wardrobe 12 ELEVATION IDENTIFICATION CL Center Line FLMT Flush Mounted MIN Minimum RFA Roofing Accessories WS Weatherstrip(ping) CLG Ceiling FLR Floor(s) MISC Miscellaneous RH Right Hand WT Weight 12 12 ACOUSTICAL CEILING BOARD CLG HT Ceiling Height FLS Floor Sealer ML Metal Lath RM Room WTR Window Treatment A� DRAWING NUMBER CLO Closet FLUOR Fluorescent ML WK Millwork RMX Resin Matrix WV Wood Veneer 12 CLR OPNG Clear Opening FO Face Of MLDG Molding RND Round(ed) WWF Welded Wire Fabric RESILIENT FLOORING CMU Concrete Masonry Unit(s) FP Fireproofing MO Masonry Opening RO Rough Opening CO Cleanout FPM Feet per Minute MP Metal Panel ROT Rotated X, Y, Z Not Used E12 PARTITION TYPE - _ _ _ _ _ _ - COL Column FIR Fire Retardant / Rating / Resist. MTD Mounted ROW Right of Way 1 JASEE PARTITION SCHEDULE WATERPROOFING CONC Concrete MTL Metal RPM Revolutions per Minute CONF Conference G MUL Mullion RR Railroad ACOUSTIC RATING CONN Connect(ion) G Gas RS Roofing System FIRE RATING (WHERE STONE CONSTR Construction GA Gauge N INDICATED) CONT Continuous / Continue GAL Gallon(s) N North S (WHERE CONY Convector GALV Galvanized NA Not Applicable SA Supply Air INDICATED) CORR Corridor GFRC Glass Fiber Reinforced Concrete NC Noise Criteria SAN Sanitary XX MATERIAL TAG CPT Carpet(ed) GFRG Glass Fiber Reinforced Gypsum NIC Not in Contract SB Splash Block CSK Countersink / Countersunk GI Galvanized Iron NO Number SCHED Schedule(d) CSWK Casework GL Glass NOM Nominal SE Sealant CEILING TAG CT Ceramic Tile GL BILK Glass Block NRC Noise Reduction Coefficient SECT Section 9' - 0" CEILING HEIGHT (AFF) Seal & Signature: CTR Center(ed) GBMC Green Building Material Certification NTS Not to Scale SHR Shower ACT-1 CEILING FINISH CU Cubic GND Ground SHT Sheet CW Cold Water GPH Gallons per Hour 0 SHTHG Sheathing 22008388 1 REGISTERED GPM Gallons per Minute CA Outside Air SIM Similar ARCHITECT GRID Grade OC On Center SLDG Slide / Sliding WALL JOINTS SHOW CHANGE IN Z6 GR Grille OD Outside Diameter SMR Sheet Metal Roofing PARTITION TYPE BENJAMIN WATERS GWB Gypsum Wallboard OF Outside Face SPC Synthetic Polymer Countertop STATE OF WASHINGTON OFD Overflow Drain SPD See Plumbing Drawings ALIGN H OFF Office SPEC Specification(s) HB Hose Bib OH DR Overhead Coiling Door SQ Square HD Head OH Opposite Hand SQ FT Square Foot / Feet HDW Hardware OPNG Opening SSD See Structural Drawings Sheet Name: HEX Hexagon(al) OPP Opposite SST Stainless Steel HM Hollow Metal OPR Operating / Operable ST Stone LEGENDS HNDRL Handrail ORD Overflow Roof Drain STC Sound Transmission Class HO Hold Open OZ Ounce STD Standard HORIZ Horizontal STL Steel HP High Point STOR Storage HR Hour(s) (Fire Resistance Rating) STRUCT Structure / Structural HT Height SURF MTD Surface Mounted HVAC Heating, Ventilating, Air Conditioning SUSP Suspend(ed) / Suspension HWY Highway SWBD Switchboard SYMM Symmetrical Project No.: Sheet No.: 21.01.38 Drawn By: Author Checked By: Checker AO . 02 Scale: 12" = 1'-0" Plan Review Stamp: Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT a 0 m Lo v v N N O N f` N LEGEND 22-14398 BARNES R503.1.1 suildlna eww+e oM suiidingenveI-ope mremhlles that are part -of the allerartlon shall cormplV Wirth 5eciaon R402.1.1 or R402.1.4, 5ectlons RW2.2-1 through R402-2.11, R4012.3-1 W2.1-2, R402-4.1 and 11402.4.4. Exaeptlan, the follawingafteratlons need not compiyrwith the requirementsf-or new constructyDn provided the energy use of the building Is not increased 1- Stcwm wirkIIows ifWalled *wet eAsting feneSirstidn, 2- Existing Wilms, wall -0r goor cavities exposed durir, or. try, #I pr*v4ed i114t theme* cpitles acre tilled with it suhotion. ZK4 franwa w$II# shall bqy Insulawd to a minimwrn of R-15 and ZEE framed wall$ awll �e Insulated to a minimum orf R-21- 3. Construction where the existing roof, wall orflum cav" is not exposed. 4. RDuF re -cower. 5. Wffs without imuiation in the cavity and where the sheathing or insulation is exposed during mrciaAn3 shall be insulated either above or below the sheathing. R. Surface agolled window film instal led *@% eKisting slmglq� pane fenestratlon asf-wblles t<3 reduce solar Peal CIA pr*vi d the c #l0e$ t4t requi re IM Rlarino fenestratiofi to be r*piaeed- R5+03.1.1-1 Replacement funastraliun. Where some or all of an existing fenestration unit is replaced with a new fcncalrakion product, including sash ;arid glaring, the mplaccmcntfrncskration unit shall me" t1we applicable rcquir*m*rr#s f& J) -faOor i§nd SHGC in TikW 114OL2,11. Whom more khan -bnt r*platijment ftnestr-Atiorl unit is btirlg in5tNiledp on area-w00ted ewer *f Sht U-facwrae+d EKC*f III replaceime t fenesteMion sh*ll be permitm-d so be used to ftmonstrate complianw. R5(113.L3 Rating and cooling systems- Mew heatieC coaling and duct syrswma that ire part of the slieeatlgi shall comply with 5ecWn R403. Ewmpl]rm! 1- Where ducts frorn an awlsting heating -end coolingswstem areexterlded, ductsVslerns with less than AEG linear feel In ummnditloned spates shall not be required to be tested In accordance with Section R403.2-2. 2- Existing duct systems constructed, Insulated or sealed with asbestos. fl .LI.Z Heating and cooling systems New heating, cooling and duet systemsthart are part flfthe addition shall tom ply with Section f Escep+tinn: The following need notcomply with the besting requirements of Section R403-3.3; 1- Additions of lei than ?SO square feet. 2. Duct systems; that are documented 4v have been pFeviouslyr sealed as cmfirmedthRough field tirerifsation and diagna5ticte5ting in accordance with pri3cedure5 in W5U RS-33. 3. Ducts with lessthan 40 linear feet in uncxnditioned spaces. 4. Existing duck systems constructed, immli ted or sealed with asbestos. R5+03.1.3 Serwks but wata svFNms. New service hm water syabems that are part4�l the alteration shall ceampiy with Section W3.5. R-W3.7 4 Uah Ufig- New ligh1I irlg sytgtms that -bgt pert of the ;)IMeMion shall comA with 5c!t#ior5 R404.1. Emepbioo, Alterations that replace less than 50 percent of the luminaires in a space, prcfvid:•d that such aiteiratio ns d4 not increase the installed inberior I Win@ power. R503.2 Change In space €onditiioning. AM nonconditioned or low -energy space that is aftere+d to became condkknied sp= shall he required to be brought into full compliance with this oude. Alterations Worksheet - 20 18 Washington State Energy Cede Pff; r:r•1 rrrliQ.rrH*fk0 -Gobfaef M¢ wfMftr- Borth$ RoidemW 129RW 301 nI $IreM FedeGA Why. VVA 9BD�3 5weP w Braun LLC Bran wqt"-m �n ,�rr,�er�.�r�ti�hrr�,urr.r,�m; 21F•��S•�1pg The VVSEC requiFemerrts for alterations are located in Chapter 5 of the cone text. Alterations (remodels) do not need to obtain energy cred its from T,9 ble R406.3 Additions mur5l meek the requirements for new construction. This inc as riancvnditioned space being allered to trecome auditioned sgmce. WIII tho wall cavifim he expmed? r Yes { Nc If yes; Exposed wall uavilies mull be insulaied - 2 X 4 wall studs req u ire R-1 S insu Iation 2 X 6 wall studs req u ire R-Z1 inskl Iatiorl WIII the ,oaf tiling framing cavities or attic be exposed? r Yes r No If yes; Exposed roofireiling ac$ernt3lies, must be in ulDto - Vaulted aeilin9a: Insulale to the full depth of the Framing member while allowing for the minimum 1" ventilated space Flaf ceilings; Install R-49 insulalion or what the attio space can accommodale cased art the roof pitch WIII the floorframing cavitlas be exposed? FYes F No If yes; Exposed floor mwitie!q must be insulated to R-30 Are the windows andfor doom balnq r-oplacad? r- Yes fw No (indkolm bosh window or dux and frarnea) If yes: New windows and doom must have an area w6ghted average U-faotar of �0.30 Wi I I the heating or Title syrstern be repkwA4? r Yes F Nk) If yes: New equipment must most current requirements and ducts need to be tested Wi l l the hat war SyStertl be altered? f-j- Y 0 & r No If yes: New water heating equipmanl must meet current code requirements Are more titian 50% of the light fiiobtures being ehanW? F ye5 r- No If y8s: 91YYo of all larnps rmUst be hlgh efficacy (LED or C FL) SHEET NOTES GENERAL NOTES RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: B U REA U B R A U N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: No.: Description: Date: 77 PLAN SET 2022-07-27 Seal & Signature: 22008388 REGISTERED ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: ENERGY FORMS Project No.: I Sheet No.: 21.01.38 Drawn By: Author Checked By: Checker Scale: 12" = 1'-0" Plan Review Stamp: A0.05 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT REMODEL WORKSHEET 0 1 SCALE: 12" = V-0" II I 1287 SW 300TH PL _ I 515320-0255 I I — S 81-120-29- I I ' I I , I� �I I I , I� �I I I �� °T-1� / 0 T-2` I � �T-2 o T-2 , I -2 / T i 0 T-3 I o o T-3 I n I UM?r-T-4 M , M M \ of cn z T-2 0 0 T-2 I I I I I I EX CONC PATIO ON GRADE 810 SF I ,—� EX DECK T-5 T-5 rQ FP: 344 SF lz' / o T-5 - - y T-5 0 FF: 325.30' PO co T-21 T-5 T -5x, I � ' T-5 � T-5 t12 0 32.0 18,9 30.0 O. 0 ROW U) / w I EX SFR W I I I w Q M ch =M I� I 0 �- Z t0 I r I EX DRWY 301 SF I L — — I FP: 1879 SF FF: 325.30' of T-6 I EX WKWY o / 220 SF S 89-24-36 E 119.48' i o o M � S 301ST ST N 89-24-36 E o M ry I I 1281 SW 300TH PL 515320-0250 1296 SW 301 ST ST 515320-0265 LEGEND 0 (D 0 22-10398 PROPERTY LINE BUILDING FOOTPRINT. RE: DWG FOR DIMS. CONTOUR LINE. RE: DWG FOR ELEV. CONIFEROUS TREE. RE: DWG FOR SPECIE, DIAM, & PHASE DECIDIOUS TREE. RE: DWG FOR SPECIE, DIAM, & PHASE TREE DRIPLINE SHEET NOTES PROPERTY DETAILS (CONT...) TREE UNIT CALCULATION: ZONING: RS 15.0 TREE UNITS PER ACRE: 25 LOT AREA: 0.88 ACRES TREE UNITS REQ'D: (25)(0.88) = 22.0 BARNES RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: B U REA U B R A U N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: No.: Description: Date: PLAN SET 2022-07-27 TREE SPECIE DBH CREDIT QTY TOTAL GENERAL NOTES T-1 MAPLE 36 3.0 1 3.0 T-2 MAPLE 12" 1.5 8 12.0 T-3 SPL MAPLE 24" 2.5 2 5.0 T-4 MAPLE CLUST 14" 2.0 1 2.0 1. SITE BOUNDARY LINES AND DIMENSIONS PROVIDED IN T-5 MAPLE 8" 1.5 8 12.0 SURVEY 22095, "BOUNDARY & TOPOGRAPHIC SURVEY OF Seal & Signature: T-6 CEDAR 48" 3.0 1 3.0 1298 SW 301 ST ST," BY 4SITE SURVEYING & CONSULTING, TOTAL 37.0 COMPLETED 1 JULY 2022. PROPERTY DETAILS 1298 SW 301 ST ST FEDERAL WAY, WA 98023 PARCEL: OWNER: LOT AREA: ZONING: MAX HEIGHT: REQ'D PARKING SPACES: 515320-0260 RONALD & MARY BARNES 38,536 SF (0.88 AC) RS 15.0 30'-0" ABOVE ABE 2/DU LEGAL DESCRIPTION: MARINE VIEW ESTATES ADD PLAT BLOCK: 3 PLAT LOT: 12 LOT COVERAGE CALCULATIONS: LOT AREA: 38,536 SF ALLOW. LOT COVERAGE: (38,536)(0.60) = 23,122 SF EX SFR FP AREA (EXCL EAVES): 1,879 SF EX DRWY: 301 SF EX WKWY: 220 SF EX CONC PATIO (LESS DECK): 614 SF EX ATT GARAGE: 707 SF EX DECK: 344 SF TOTAL: 4,065 SF TOTAL LOT COVERAGE: 4,065 < 23,122 OK 37.0 > 22.0 OK NORTH 2. NO TREE REMOVAL IS PROPOSED. ALL EXISTING TREES TO REMAIN. 3. FRONT YARD SETBACKS PER FEDERAL WAY REVISED CODE 19.200.010.3. 4. VERIFY EXISTING UNDERGROUND UTILITY LOCATIONS PRIOR TO THE COMMENCEMENT OF WORK. 22008388 REGISTERED ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: SITE PLAN Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: As indicated Plan Review Stamp Sheet No.: A0.10 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT SITE PLAN 0 1 SCALE: V = 20'-0" LEGEND 22-10 398 I I I I I I I I I I I I I I I I I I I I I I I I II I I I I I I I I I I I I I I I I I I I I I EX FURNACE CHIMNEY EX CONC SLAB EX FIREPLACE FOUND & FTG, VIF VIF CHIMNEY FOUND & L J FTG, VIF I I I I IL I I I J I I I I I ---J I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I J I I I I I I I I EX PERIM FOUND & FTG, VIF I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I EX CONC SLAB I I VIF I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I L J L------------------------------------------------ -J AO 1 A5.00 NORTH 23 NOT IN CONTRACT EXISTING PARTITION TO REMAIN NEW DRYWALL PARTITION EXISTING PARTITION TO BE DEMOLISHED COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED BARNES RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: ExHFUsTFAN B U R E A U B R A U N SHEET NOTES GENERAL NOTES 1. VERIFY EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND NOTIFY ARCH OF ANY DISCREPANCIES. BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: No.: Description: Date: PLAN SET 2022-07-27 Seal & Signature: 22008388 REGISTERED V--) ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: EX FOUNDATION PLAN Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 114" = 1'-01, Plan Review Stamp Sheet No.: A0.90 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT EX FOUNDATION PLAN 0 1 SCALE: 1/4" = V-0" LEGEND 22-11398 NOT IN CONTRACT BARNES EXISTING PARTITION TO REMAIN RESIDENCE REMODEL NEW DRYWALL PARTITION 1298 SW 301 ST STREET EXISTING PARTITION TO BE DEMOLISHED FEDERAL WAY, WA 98023 SD COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED Architect: EF EXHAUST FAN B U R E A U B R A U N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: SHEET NOTES No.: Description: Date: PLAN SET 2022-07-27 GENERAL NOTES NORTH Seal & Signature: 22008388 REGISTERED ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: EX PLAN - BASEMENT Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/4" = 1'-01, Plan Review Stamp Sheet No.: A1.00 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT EXISTING PLAN - BASEMENT 0 1 SCALE: 1 /4" = 1'-0" LEGEND 22-10b398 NOT IN CONTRACT BARNES EX NG RINNAI 2532 TANKLESS DHW (180K BTUH; UEF: 80), FLUE DIRECT TO EXTERIOR PPSD NG DWH TO COMPLY W/ WSEC R403.5. EX NG LENNOX EL280UH FURN (11OK BTUH; AFUE: 80), FLUE TO CHIMNEY PPSD 2X4 @ 16" OC INTERIOR WALL (NON LOAD -BEARING) EX ELEC PANEL 01 A5.00 BATH REMODEL: CIVTI MCC 0 CIAIIQLJCQ NORTH EXISTING PARTITION TO REMAIN NEW DRYWALL PARTITION EXISTING PARTITION TO BE DEMOLISHED COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED EXHAUSTFAN SHEET NOTES GENERAL NOTES 1. PROVIDE EXHAUST FANS AT EACH BATHROOM: 50CFM MIN INTERMITTENT. 2. PROPOSED STAIR AT PPSD UTILITY ROOM: COMPLY WITH WSRC R311.7. RISE AND RUN PER R311.7.5.1 & 2: A. MAX RISE 7-3/4" - RISER HEGHT DIFFERENCE WITHIN FLIGHT OF STAIRS SHALL NOT EXCEED 3/8" B. MIN RUN (TREAD DEPTH) SHALL BE 10" C. HANDRAILS PER WSRC R311.7.8, NOT LESS THAN 34" OR MORE THAN 48" ABOVE STAIR D. NOSING, ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. E. HANDGRIP PER WSRC R311.6.63: NOT LESS THAN 1-1/4" OR MORE THAN 2" DIA., PROJECT MIN. 1-1/2" FROM WALL. HEADROOM PER WSRC R311.8.2 6'-8" MIN. 3. TUB / SHOWER NOTES: COMPLY WITH WSRC R307 NON ABSORBENT SURFACE. GWB, NO VAPOR BARRIER BEHIND WATER RESISTANT GWB SPECIFIED AS BASE FOR TILE ON SHOWER ENCLOSURES, WATER RESISTANT GWB NOT INSTALLED ON CEILING IF FRAMING EXCEEDS 12" OC. A. WALLS AND SHOWERS: WATERPROOF TO 72" ABOVE DRAIN INLET. SHOWER DOORS PER WSRC R308 COMPLY WITH SAFETY GLAZING REQUIREMENTS. B. SHOWER FLOOR TO 2.5 GPM. 4. ATTIC ACCESS PER WSRC R807, 22" X 30" MIN OPENING, 30" MIN CLEAR. 5. GUARD RAILS PER WSRC R312 MIN 36" HEIGHT PER WSRC R312.1, ,4" MAX SPACE BETWEEN RAILS - WSRC R312.3 TRIANGULAR OPENINGS AT RISER, TREAD, BOTTOM ELEMENT OF RAIL, 6" MAX. 6. EMERGECY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN BASEMENT, HABITABLE ATTICS, AND IN SLEEPING ROOMS; OPENABLE W/O USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE PER IRC 310: A. MIN 5.7 SF NET CLR OPENABLE AREA; B. MIN 24" NET CLR OPENABLE AREA; C. MIN 20" NET CLR OPENABLE WIDTH; AND D. MAX 44" FINISHED SILL HEIGHT. 7. PROVIDE APPROVED COMBO SMOKE & CARBON MONOXIDE ALARMS WHERE INDICATED ON PLANS. ALL ALARMS SHALL BE HARDWIRED AND INTERCONNECTED AND COMPLY WITH WSRC R314 & R315. RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: B U REA U B R A U N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: No.: Description: Date: PLAN SET 2022-07-27 Seal & Signature: 22008388 REGISTERED ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: PPSD PLAN - BASEMENT Project No.: Sheet No.: 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/4" = 1'-01, Q I Plan Review Stamp A1.01 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT PROPOSED PLAN - BASEMENT 0 1 SCALE: 1/4" = V-0" LEGEND 22-11398 NOT IN CONTRACT BARNES RESIDENCE EXISTING PARTITION TO REMAIN REMODEL NEW DRYWALL PARTITION 1298 SW 301 ST STREET EXISTING PARTITION TO BE DEMOLISHED FEDERAL WAY, WA 98023 SD COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED Architect: fo E°„A°sT°FN B U R E A U B RAU N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: SHEET NOTES No.: Description: Date: PLAN SET 2022-07-27 GENERAL NOTES NORTH Seal & Signature: 22008388 REGISTERED ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: EX PLAN - MAIN FLOOR Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/4" = 1'-01, Plan Review Stamp Sheet No.: A1.10 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT EXISTING PLAN - MAIN FLOOR n SCALE: 1/4" = V-0" V LEGEND 22-11398 01 A5.00 NOT IN CONTRACT EXISTING PARTITION TO REMAIN BARNES RESIDENCE REMODEL NEW DRYWALL PARTITION 1298 SW 301 ST STREET EXISTING PARTITION TO BE DEMOLISHED FEDERAL WAY, WA 98023 COMBO SMOKE & CARBON MONOXIDE SD DETECTOR; HARDWIRED & INTERCONNECTED Architect: EF EXHAUST FAN B U R E A U \\ B R A U N BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 NORTH SHEET NOTES GENERAL NOTES 1. VERIFY EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND NOTIFY ARCH OF ANY DISCREPANCIES. Consultants: Issued For: No.: Description: Date: PLAN SET 2022-07-27 Seal & Signature: 22008388 REGISTERED V--) ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: EX FRAMING PLAN - MAIN FLOOR Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/4" = 1'-01, Plan Review Stamp Sheet No.: A1.11 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT EXISTING FLOOR FRAMING PLAN SCALE: 1/4" = V-0" 0 1 LEGEND 22-10b398 NOT IN CONTRACT BARNES FURR OUT EX � FOR PLUMB AC EXISTING PARTITION TO REMAIN NEW DRYWALL PARTITION EXISTING PARTITION TO BE DEMOLISHED COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: to ExHA°s'F°N B U R E A U B R A U N SHEET NOTES GENERAL NOTES BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: Issued For: No.: Description: Date:11 PLAN SET 2022-07-27 104C vv 1. PROVIDE EXHAUST FANS AT EACH BATHROOM: 50CFM MIN INTERMITTENT. 2. PROPOSED STAIR AT PPSD UTILITY ROOM: COMPLY WITH Seal & Signature: WSRC R311.7. RISE AND RUN PER R311.7.5.1 & 2: so so A. MAX RISE 7-3/4" - RISER HEGHT DIFFERENCE WITHIN 22008388 FLIGHT OF STAIRS SHALL NOT EXCEED 3/8" REGISTERED BED CL BED B. MIN RUN (TREAD DEPTH) SHALL BE 10" C. HANDRAILS PER WSRC R311.7.8, NOT LESS THAN 34" OR ARCHITECT 107 104D o MORE THAN 48" ABOVE STAIR BENJAMIN WATERS C:) 108 D. NOSING, ENDS SHALL BE RETURNED OR SHALL STATE OF WASHINGTON TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. E. HANDGRIP PER WSRC R311.6.63: NOT LESS THAN 1-1/4" OR MORE THAN 2" DIA., PROJECT MIN. 1-1/2" FROM WALL. HEADROOM PER WSRC R311.8.2 6'-8" MIN. EGRESS E RESS 3. TUB / SHOWER NOTES: COMPLY WITH WSRC R307 NON Sheet Name: ABSORBENT SURFACE. GWB, NO VAPOR BARRIER BEHIND WATER RESISTANT GWB SPECIFIED AS BASE FOR TILE ON P PS D PLAN - EX 5040 HSOX CL CL EX 5040 HSOX SHOWER ENCLOSURES, WATER RESISTANT GWB NOT 107A 108A 01 INSTALLED ON CEILING IF FRAMING EXCEEDS 12" OC. MAIN FLOOR A. WALLS AND SHOWERS: WATERPROOF TO 72" ABOVE A5.00 DRAIN INLET. SHOWER DOORS PER WSRC R308 COMPLY WITH SAFETY GLAZING REQUIREMENTS. B. SHOWER FLOOR TO 2.5 GPM. 4. ATTIC ACCESS PER WSRC R807, 22" X 30" MIN OPENING, 30" MIN CLEAR. 5. GUARD RAILS PER WSRC R312 MIN 36" HEIGHT PER WSRC R312.1, ,4" MAX SPACE BETWEEN RAILS - WSRC R312.3 Project No.: Sheet No.: TRIANGULAR OPENINGS AT RISER, TREAD, BOTTOM 21.01.38 ELEMENT OF RAIL, 6" MAX. Drawn By: Author Checked By: Checker Al 12 6. EMERGECY ESCAPE AND RESCUE OPENINGS SHALL BE INSTALLED IN BASEMENT, HABITABLE ATTICS, AND IN Scale: SLEEPING ROOMS; OPENABLE W/O USE OF KEYS, TOOLS, Plan Review Stamp: OR SPECIAL KNOWLEDGE PER IRC 310: A. MIN 5.7 SF NET CLR OPENABLE AREA; Aug 10 2022 B. MIN 24" NET CLR OPENABLE AREA; C. MIN 20" NET CLR OPENABLE WIDTH; AND NORTH D. MAX 44" FINISHED SILL HEIGHT. CITY of FEDERAL WAY 7. PROVIDE APPROVED COMBO SMOKE & CARBON MONOXIDE COMMUNITY DEVELOPMENT ALARMS WHERE INDICATED ON PLANS. ALL ALARMS SHALL BE HARDWIRED AND INTERCONNECTED AND COMPLY WITH WSRC R314 & R315. PROPOSED PLAN - MAIN FLOOR n SCALE: 1/4" = V-0" V LEGEND 22-11398 EX 2X6 CLNG JOISTS AT 16" OC VIF NORTH 21 NOT IN CONTRACT EXISTING PARTITION TO REMAIN NEW DRYWALL PARTITION EXISTING PARTITION TO BE DEMOLISHED COMBO SMOKE & CARBON MONOXIDE DETECTOR; HARDWIRED & INTERCONNECTED BARNES RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: ExH°°sT°AN B U R E A U B RAU N SHEET NOTES GENERAL NOTES 1. VERIFY EXISTING CONDITIONS PRIOR TO THE COMMENCEMENT OF WORK AND NOTIFY ARCH OF ANY DISCREPANCIES. BUREAU BRAUN, LLC 100 WARD ST APT 203, SEATTLE, WA 98109 Consultants: B2 ENGINEERS, PLLC 10600 WOODINVILLE DR, BOTHELL, WA 98011 Issued For: No.: Description: Date: PLAN SET 2022-07-27 Seal & Signature: 22008388 REGISTERED V--) ARCHITECT BENJAMIN WATERS STATE OF WASHINGTON Sheet Name: EX CEILING FRAMING PLAN Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/4" = 1'-01, Plan Review Stamp Sheet No.: A1.23 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT LO M Lo N N O N N EXISTING CEILING FRAMING PLAN 0 1 SCALE: 1/4" = V-0" 22-11398 BARNES EX FURNACE CHII REMAIN. UL1777 F MMr%rI e1\/ MIMI I IA/AI I nnnn n\/n IAIT IAIAI I . nAnl Ir-rl I Mir- IAIrNinATr-!l ry EX CHIMNEY FOUNDATIONS BEYOND RESIDENCE REMODEL 1298 SW 301 ST STREET FEDERAL WAY, WA 98023 Architect: BUREAU EX TYP 2X FLOOR: SUBFLOOR B N U �A I I • • 2X JOIST • R-30 INSUL (WHERE BUREAU BRAUN, LLC OCCURS) 100 WARD ST APT 203, SEATTLE, WA 98109 • 1/2" GWB Consultants: EX TYP 2X CEILING: • 2X JOIST • R-491NSUL • 1/2" GWB B2 ENGINEERS, PLLC 10600 WOODINVILLE DR, BOTHELL, WA 98011 EX RIDGE 21'-0" Issued For: No.: Description: Date: PLAN SET 2022-07-27 EX MAIN FIN CLNG 15'-8 1/2" 1:*01 VA W4A►1T/11I= • SHEATHING • 2X STUD • R-21 INT INSUL • 1/2" GWB EX MAIN FIN FL 8'-0 1/2" EX GAR FIN CLNG 71-011 Seal &Signature: EX TYPE'X' GWB AT 22008388 REGISTERED GARAGE WALLS AND CLNGV--) ARCHITECT E WAT MIN WATERS EX CONC SLAB ON STATE BENJAA IN WAT RS GRADE EX CONC PERIM FOUND & FOOTING Sheet Name: BUILDING EX BSMT 4L SECTION 0'-0" EX GARAGE -1'-3 1/2" Project No 21.01.38 Drawn By: Author Checked By: Checker Scale: 1/2" = 1'-01, Plan Review Stamp Sheet No.: A5.00 Aug 10 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT LO M Lo N N O N f` N BUILDING SECTION 0 1 SCALE: 1/2" = 1'-0"