Loading...
22-104507MechanicalPlanSet 10.03.2022GENERAL INFORMATION PROPERTY TAX NO.: 873190-2740 LEGAL DESCRIPTION: TWIN LAKES #2 ALL OF TRACTS B, C, D & E OF TWIN LAKES DIV NO 2 TGW UNPLATTED POR IN S 1/2 OF E 1/2 OF NW 1/4 OF SEC 13-21-04 LY NLY OF SW 327TH ST LESS PARCEL 1 OF FAIRWAY TERRACE CONDO LESS E 520 FT TGW ALL TRACT A & B TRACT C LESS POR LY ELY OF A LN RNG N 00-51-31 E 64,15 FT FR SW CDR OF LOT 75 OF TWIN LAKES DIV NO 5 TH N 51-41-20 E 41 FT TO MOST NLY CDR OF LOT 75 TGW ALL TRACTS D & E OF TWIN LAKES DIV NO 5 TGW UNPLATTED POR OF SW 1/4 OF NE 1/4 OF SEC 11-21-03 LY SLY & ELY OF SW DASH PT RD & ELY OF LOT 9 OF TWIN LAKES DIV NO 6 TGW UNPLATTED POR IN NW 1/4 OF NW 1/4 OF SEC 13-21-03 LY NLY OF SW 320TH ST & WLY OF A LN - BEG NW CDR OF NW 1/4 OF NW 1/4 TH E ALG N LN 410,67 FT TH S 00-55-53 W 75 FT TH S 08-32-13 W 167,92 FT TH S 27-10-26 W 306,18 FT TH S 26-20-42 E 168 FT TO NLY MGN OF SW 320TH ST & TERM OF SD LN LESS POR - BEG INTSN OF WLY MGN OF NW 1/4 OF NW 1/4 WITH NLY MGN OF SW 320TH ST TH N 01-45-46 E ALG SD WLY MGN 60 FT TH S 88-14-44 E 165 FT TH S 01-45-46 W TO SD NLY MGN TH WLY ALG SD MGN TO TPOB LESS POR LY NELY OF LN DAF - BEG MOST NLY CDR LOT 8 TWIN LAKES #6 ADD TH S 62-56-07 E 14,86 FT TH N 62-07-34 E 39,26 FT TO TPOB OF SD LN TH S 21-10-25 E TO NELY BDRY OF SD LOT 8 & TERMINUS OF SD LN TGW POR SD LOT 8 LY SWLY OF LD DAF - BEG MOST NLY CDR SD LOT 8 TWIN LAKES #6 ADD TH S 62-57-06 E 14,86 FT TH CONT S 56-43-09 E 67,07 FT TO TPOB OF SD LN TH S 21 -10-25 E 18,61 FT TO TERMINUS OF SD LN PER FW BLA 91-0004 REC # 9108219001 - & LESS PORS OF TR C OF PLAT OF TWIN LAKES #2 LY ADJ TO LOTS 166 THRU 168 & 170 & 176 & 266 OF SD PLAT AS LESSER OUT FROM DESCRIPTION OF PARCEL 1 OF FEDERAL WAY LLA #BLA99-0012 REC #20000121900004 LESS POR TR "E" OF SD ADD DAF - COMM AT NE CDR LOT 1 TWIN LAKES DIVISION #5, SD PT BEING TPOB; TH S 18-37-15E 64,68 FT; TH ALG CRV RT THRU DELTA ANG 90-00-00, RAID 35 FT ALG ARC LENGTH 54,98 FT TO A PT; TH S71-22-45W 72,95 FT TO SLY CDR LOT 1 OF SD ADD; TH ALG CUR TO LF WHOSE BACK TAN BRS N75- 56-19E, THRU DELTA ANG 94-33-33, A RAD OF 100 FT ALG ARC LENGTH OF 165,04 FT TO POB PROJECT LOCATION: 3583 SW 320TH STREET FEDERAL WAY, WA 98023 PROJECT DESCRIPTION: EXISTING BUILDING TENANT IMPROVEMENT, SCOPE ONLY APPLIES TO THE ADDITION OF TWO COOLING SYSTEMS USING SPLIT SYSTEM HEAT PUMPS, EACH SERVING ONE ZONE HVAC CONTRACTOR: EMERALD AIRE INC 5108 D STREET AUBURN, WA 98001 PROJECT MANAGER: CONTACT: EMERALD A I RE, INC, VO I CEI (253) 872-5665 FAX: (253) 872-5797 INDEX: TWIN SAKES COUNTRY CHUB T GENERAL MECHANICAL: STANDARDS: EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL, ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, MFPA, OTHER APPLICABLE AGENCIES AND AHJ AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY CODES: ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE MOST STRICT STANDARD (IN THE OPINION OF THE ENGINEER) SHALL APPLY, THE MECHANICAL CONTRACTOR SHAL SATISFY CODE REQUIREMENTS & REQUIREMENTS OF THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD, APPLICABLE CODES: 2018 IMC W/WASHINGTON STATE AMENDMENTS. 2018 IBC W/WASHINGTON STATE AMENDMENTS 2017 NATIONAL 2018 WASHINGTON STATE ENERGY CODE GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS, VICINITY MAP: ement a NOT TO SCALE HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Twin Lakes Date 9/22/2022 System Name Fitness Room Floor Area 1,000 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM Total Room Loads 879 Return Vented Lighting Return Air Ducts Return Fan Ventilation 15 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 18,965 7,692 63 2,847 Total Output (Btuh) 0 Output (Btuh/sgft) 0 0 Cooling System 0 0 Output per System 137 218 15 795 Total Output (Btuh) 0 7,474 0 Total Output (Tons) 0 0 Total Output (Btuh/sgft) Total Output (sqft/Ton) 19,102 3,642 Air System CFM per System HVAC EQUIPMENT SELECTION Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Jan 1 AM Outside Air (cfm/sqft) Note: values above given at ARI conditions Sep 2 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 19 IF Outside Air 15 cfm 68 OF 67 OF 110 OF F_ -:T Heating Coil 1 10°F ROOM 68 OF I COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 83/65IF Outside Air 15 cfm 75/66OF 55/54OF Cooling Coil 63.9 % 55 / 54 OF ROOM ff 75 / 66 IF EnergyPro 5.1 by EnergySoft User Number: 7487 RunCode: 2022-09-22T14:12:08 ID: Page 2 of 10 rq :,din Golf and Cc Tr Club --I Meyer 9 BJ's Bingo & Ga �J, IK Fede:al way I,1 it Rhcdeclend-on species Botaniral Gar n Wild Waves.Theme71, and Water Park a Fife Heights f ��hnla WSEC & COMMISSIONING NOTES: THERMOSTATS SHALL BE INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING PER WSEC 403, 2, 4, 1, 1 ECONOMIZERS SHALL MODULATE OUTSIDE AIR FROM MINIMUM TO 100% ECONOMIZER CONTROLS SHALL BE CAPABLE OF EVALUATING OUTDOOR AIR COOLING CAPACITY PER WSEC C403, 3, 1, 1 INSULATE REFRIGERANT PIPING PER WSEC TABLE C403,2,8 SEAL DUCTWORK PER WSEC C403, 2, 7, 3 INSULATE DUCTWORK PER WSEC C403, 2, 7, 1 AND C403, 2, 7, 2 COMMISSIONING PER WSEC C408 INCLUDING COMMISSIONING PLAN, SYSTEMS Lakeland BALANCING, FUNCTIONAL TESTING, CONTROLS TESTING, OPERATION AND South MAINTENANCE MANUALS, AND RECORD DRAWINGS, SHALL BE SUBMITTED TO OWNER ON PROJECT COMPLETION, Milton Edgewood INSTALL ALL THERMOSTATS AT 48' AFF HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Twin Lakes Date 9/22/2022 System Name Main Shop Floor Area 1,800 ENGINEERING CHECKS SYSTEM LOAD Number of Systems COIL CFM Total Room Loads 808 Return Vented Lighting Return Air Ducts Return Fan Ventilation 104 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 16,557 2,769 114 4,918 Total Output (Btuh) 0 Output (Btuh/sgft) 0 0 Cooling System 0 0 Output per System 1,232 245 104 5,729 Total Output (Btuh) 0 3,014 0 Total Output (Tons) 0 0 Total Output (Btuh/sgft) Total Output (sqft/Ton) 17,789 10,647 Air System CFM per System HVAC EOUIPMENT SELECTION Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK Jan 1 AM Outside Air (cfm/sgft) Note: values above given at ARI conditions Jun 3 PM HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 19 IF Outside Air 104 cfm AL 70 OF 64 OF 110 °F Heating Coil 110 OF ROOM ]n 70 OF COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 85/66OF 110 A Outside Air 104 cfm AL 75/62OF 55/54OF Cooling Coil -� 55 / 54 OF 50.7 % ROOM 74 / 62 IF I EnergyPro 5.1 by EnergySoft User Number: 7487 RunCode: 2022-09-22T14:12:08 ID: Page 1 of 10 RECEIVED Oct 18 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 22-104507 HVAC LEGEND & ABBREVIATIONS: N CK S E "ME E GRD IDENTIFIER CFM n U SIDE WALL GRILL ® SUPPLY GRILLE ® THERMAFUSER ® RETURN AIR GRILLE 0 EXHAUST GRILLE ® EXHAUST FAN aEll EQUIPMENT TAG O T-STAT t;As CO/NO 2 SENSOR occ OCCUPANCY SENSOR - L/V WIRE ® DUCT RUN ELBOW ® REDUCER SIDE TAPS 90 ELBOW W/ TURNING VANES /im\\8\ nmo\\ FLEXIBLE DUCT --+ C�3 MANUAL DAMPER F E FIRE DAMPER sD ID SMOKE DAMPER SFD SFD EP SMOKE/FIRE DAMPER E73 MOTORIZED DAMPER _T_ ETD BACKDRAFT DAMPER v v VARIABLE VOLUME/TEMPERATURE HP HEAT PUMP HP HORSEPOWER HTG HEATING HTR HEATER ID INSIDE DIAMETER IN INCHES KW KILOWATT LAT LEAVING AIR TEMPERATURE LBS. POUNDS LWT LEAVING WATER TEMPERATURE MA MIXED AIR MAX MAXIMUM MBH THOUSAND BTU'S PER HOUR MIN MINIMUM MS MOTOR STARTER NC NOISE CRITERIA NTS NOT TO SCALE OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIAMETER PH PHASE PSI POUNDS PER SQUARE INCH QTY QUANTITY R/A RETURN AIR REF REFRIGERANT RET RETURN RH RELATIVE HUMIDITY RLD RELIEF DAMPER RPM REVOLUTIONS PER MINUTE S/A SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATING SH SENSIBLE HEAT SOV SHUT OFF VALVE SP STATIC PRESSURE TEMP TEMPERATURE UC UNDERCUT DOOR V VOLT VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (HAND OPERATOR) VEL VELOCITY W WATT W/ WITH WB WET BULB W/0 WITHOUT SEATTLE DPD STAMP z 0 U F- to z 0 U 0 LL_ I- 0 z to 11 Y Of Q 0 z U) X Lv LL_ 0 z 0 w J 0 U Of 0 LL_ 0 Lv w z 0 H U N W (n z 0 in of Lv 0 Li w PLOT DATE 9/22/2022 z w Lv m 0 z U) Q C� z_ Q 0f 0 H DESIGN DEVELOPMENT ❑ DRAWING DATE -- ❑ COORDINATION DATE ® PERMIT DATE ❑ CONSTRUCTION DATE ❑ AS BUILT DATE m J U lco N O Q 0 "r, U �J a � iY 00 0 W Ld �w >z_ m z J F IJ J Q F U Q1 J �r-m 3�-tDNLACD Z� L0.-.NQ I �Q c~it3�000^Of w 00 of r j L�J N w o� Lr, wv LO D Lli X �-: J LL. 0 o Q a � L) w L� e 0 a CL c QO U � N nnn 1=J X w nnn HVAC COVER SHEET SCALE: AS -NOTED M0.00 9/22/2022 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\MO.00 HVAC COVER SHEET.dwg xxx-xxxx Job Name: System Reference: Indoor Unit: MSZ-GL24NA FC-1 Date: Outdoor Unit: ❑ MUZ-GL24NA-U1 HP1 Wireless Remote Controller ❑ MUZ-GL24NA-U2 644 GENERAL FEATURES Slim wall -mounted indoor units provide zone comfort control The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance Multiple fan speed options: Quiet, Low, Medium, High, Super -high, Auto Multiple control options available: Hand-held Remote Controller (provided with unit) kumo cloud® smart device app for remote access Third -party interface options Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life Specifications are subject to change without notice. Maximum Capacity BTU/H 31,400 Rated Capacity BTU/H 22,400 Minimum Capacity BTU/H 8,200 Cooling' Maximum Power Input W 3,522 Rated Power Input W Pints/h 1,800 5.1 Moisture Removal Sensible Heat Factor 0.75 Power Factor % 99 / 99 Maximum Capacity BTU/H 36,900 Rated Capacity BTU/H 27,600 Heating 47°F2 Minimum Capacity BTU/H 7,500 at Maximum Power Input W 3,592 Rated Power Input W 2,340 Power Factor % 99 / 99 Maximum Capacity BTU/H 24,600 Heating 17°F3 Rated Capacity BTU/H 16,000 at Maximum Power Input W 3,232 Rated Power Input W 1,712 Heating 5°F4 Maximum Capacity BTU/H 19,320 at Maximum Power Input W 2,990 Heating at-4°F5 Maximum Capacity BTU/H 15,450 ■ 12.5 EER7 HSPF (IV) 10.0 Efficiency COP at 47°F2 3.46 COP at 17°F in Maximum Capacity3 2.23 COP at 5°F in Maximum Capacity4 1.89 ENERGY STAR® certified units (ENERGY STAR products are third -party certified by an EPA -recognized Certification Body.) YES Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor -Outdoor, S1-S2 VAC 208 / 230 Electrical Voltage: Indoor -Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size (Outdoor) A 20 Recommended Wire Size (Indoor - Outdoor) AWG 14 MCA A 1 MOCP A 20 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 56 Airflow Rate at Cooling, Dry CFM 738-628-544-469-388 Airflow Rate at Cooling, Wet CFM 661-562-487-420-347 Airflow Rate at Heating, Dry CFM 738-628-544-469-388 Indoor Unit Sound Pressure Level (Cooling) dB(A) 53-49-45-41-34 Sound Pressure Level (Heating) dB(A) 52-49-45-41-32 Drain Pipe Size In. (mm) 5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm) 43-5/16 (1,100) D: In. (mm) 9-3/8 (238) H: In. (mm) 12-13/16 (325) © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. Job Name: System Reference: Date: FC-2J 0 I��I����IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII� •'unllllllllllul'" Indoor Unit Outdoor Unit, INDOOR UNIT FEATURES • Dual Barrier Coating • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Low, Medium, High, Super High • Multiple control options available: o Hand-held Remote Controller (provided with unit) o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers • Hot -Start Technology: no cold air rush at equipment startup or when restarting after defrost cycle • Powerful Operation: quickly cools or heats the room by automatically adjusting fan speed and set temperature for 15 minutes • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Wide Vane mode provides 150° of airflow 'Auto and Powerful modes available in addition to the four fan speeds OUTDOOR UNIT FEATURES • Dual Barrier Coating • Slim wall -mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Low, Medium, High, Super High • Multiple control options available: o Hand-held Remote Controller (provided with unit) o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers • Hot -Start Technology: no cold air rush at equipment startup or when restarting after defrost cycle • Powerful Operation: quickly cools or heats the room by automatically adjusting fan speed and set temperature for 15 minutes • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Wide Vane mode provides 150° of airflow *Auto and Powerful modes available in addition to the four fan speeds Specifications are subject to change without notice. MSZ-GS30NA MUZ-GS30NA Package Dimensions W: In. (mm) 45-1/2 (1,160) D: In. (mm) 12-3/4 (320) H: In. (mm) 15-1/2 (390) Unit Weight Lbs. (kg) 37 (17) Package Weight Lbs. (kg) 42(19) Indoor Unit Operating Cooling Intake Air Temp (Maximum / Minimum)* °F 90 DB, 73 WB / 67 DB, 57 WB Temperature Range Heating Intake Air Temp (Maximum / Minimum) °F 80 DB / 70 DB MCA A 17.1 MOCP A 20 Fan Motor Full Load Amperage A 0.93 Fan Motor Output W 77 Airflow Rate CFM 1,769 / 1,701 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling' dB(A) 55 Sound Pressure Level, Heatingz dB(A) 55 Compressor Type DC INVERTER -driven Compressor Model SNB172FQKMT Outdoor Unit Compressor Rated Load Amps A 12.9 Compressor Locked Rotor Amps A 16.1 Compressor Oil Type // Charge oz. FV50S // 13.5 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm) 33-1/16 (840) D: In. (mm) 13 (330) H: In. (mm) 34-5/8 [880] Package Dimensions W: In. (mm) 38-9/16 (980) D: In. (mm) 16-9/16 (420) H: In. (mm) 39 (990) Unit Weight Lbs. (kg) 119 [54] Package Weight Lbs. (kg) 138(63) Cooling Air Temp (Maximum / Minimum)* °F 115 / 14 Outdoor Unit Operating Cooling Thermal Lock -out / Re -start Temperatures** °F -4/0 Temperature Range Heating Air Temp (Maximum / Minimum) °F 75/4 Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 4,3 Gas Pipe Size O.D. (Flared) In. (mm) 5/8 (15.88) Liquid Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52) Piping Maximum Piping Length Ft. (m) 100 (30) Maximum Height Difference Ft. (m) 50 (15) Maximum Number of Bends 10 © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Specifications are subject to change without notice. Cooling at 95°F' Maximum Capacity BTU/H 30,700 Rated Capacity Minimum Capacity BTU/H 30,600 10,300 BTU/H Maximum Power Input Rated Power Input W 3,320 W 3,320 Moisture Removal Pints/h 7.8 Sensible Heat Factor 0.72 Power Factor % 98.0/98.0 Heating at 47*F2 Maximum Capacity BTU/H 34,000 Rated Capacity BTU/H 32,600 Minimum Capacity BTU/H 9,800 Maximum Power Input W 3,580 Rated Power Input W 3,340 Power Factor % 98.0/98.0 Heating at 17°F3 Maximum Capacity BTU/H 2O,800 Rated Capacity BTU/H 21,000 Maximum Power Input W 2,600 Rated Power Input W 2,500 Heating at 5°F4 Maximum Capacity BTU/H 18,800 Maximum Power Input W 2,230 Heating at-4°F' .n,.,,... r,.. ;,1. Efficiency EER' 9.25 HSPF [IV] 9.6 COP at 47°F' 2.86 COP at 17°Fat Maximum Capacity3 2.34 COP at 5°F at Maximum Capacity' 2.47 COP at -4°F at Maximum Capacity' 2.17 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 2081230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 20 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 1.0 Fan Motor Full Load Amperage A 0.76 Fan Motor Output W 56 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 374-602-699-915 Airflow Rate at Cooling, Wet CFM 374-602-699-915 Airflow Rate at Heating, Dry CFM 374-602-699-803 Sound Pressure Level [Cooling] dB[A] 32-42-49-53 Sound Pressure Level [Heating] dB[A] 34--42-49-50 Drain Pipe Size In. [mm] 5/8 [15.881 Coating on Heat Exchanger Dual Barrier Coating External Finish Color Munsell 1.0Y 9.2/0.2 White Unit Dimensions W x D x H: In. [mm] 46-1/16 x 11-5/8 x 14-3/8 [1170 x 295 x 365] Package Dimensions W x D x H: In. [mm] 51 x 18-1/2 x 14-1/4 [1300 x 470 x 360] Unit Weight Lbs. [kg] 45 [20] Package Weight Lbs. [kg] 51 [22.9] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights resSpe]cations are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA A 19.0 MOCP A 20 Fan Motor Full Load Amperage A 0.93 Airflow Rate CFM 1974/1950 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 55 Sound Pressure Level, Heating2 dB(A) 57 Compressor Type Twin Rotary Compressor Model SNB220FQAMlT Compressor Rated Load Amps A 13.8 Compressor Locked RotorAmps A 17.3 External Finish Color Munsell 3Y 7.8/1/1 Unit Dimensions W x D x H: In. [mm] 33-1/16 x 13 x 34-5/8 [840 x 330 x 880] Package Dimensions W x D x H: In. [mm] 38-3/4 x 16-3/4 x 39 [980 x 420 x 9901 Unit Weight Lbs. [kg] 121 [55.0] Package Weight Lbs. [kg] 138 [62.51 Outdoor Unit Operating Temperature range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 14 DB Cooling Thermal Lock -out / Re -start Temperatures** °F -4/0 Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -4 DB, -5 WB Heating Thermal Lock -out / Re -start Temperatures** °F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 4, 16.0 Chargeless Piping Length Ft. [m] 25.0 [7.5] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 1.08 [20] Piping Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 1/4 [6.35] Maximum Piping Length Ft. [m] 100 [30] Maximum Height Difference Ft. [m] 50 [15] Maximum Number of Bends 10 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 'Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB H 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB 'Heating at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB H -4 DB, -5 WB 'Heating at -5°F (Indoor // Outdoor) °F 70 DB, 60 WB H -5 DB, -6 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rightsS0mft1Qdions are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. GENERAL NOTES: 22-104507 - WALL MOUNT OUTDOOR UNIT USING BUYOUT BRACKETS - SPEEDICHANNEL TO CONCEAL REFER PIPING - EC TO WIRE SYSTEMS USING WIRE GAGE REQUIRED IN INSTALLATION MANUAL ECONOMIZER EXCEPTION: - NO ECONOMIZER PER 2018 WSEC C503.4.2, EXCEPTION 1, ECONOMIZERS NOT REQUIRED FOR SPLIT SYSTEMS SERVING ONE ZONE WITH CAPACITY LESS THAN 33MBH, SEER AND EER VALUES ARE GREATER THAN 15% HIGHER THAN MINIMUM EFFICIENCIES LISTED IN TABLES C403.3.2, TOTAL CAPACITY OF ALL EQUIPMENT WITHOUT ECONOMIZERS DO NOT EXCEED THE 72MBH LIMIT MINIMUM REQUIRED EFFICIENCY TO COMPLY WITH C503.4.2 - MUST BE 15% GREATER THAN 13.0 SEER LISTED FOR AIR COOLED AIR CONDITIONERS WITH CAPACITY UNDER 65,000 MBH. EFFICIENCY MUST MEET OR EXCEED 14.3 SEER. HP-1 - 20.5 SEER (COMPLIES) - THIS UNIT ALSO COMPLIES WITH ECONOMIZER EXCEPTION TABLE C403.5. THIS UNIT HAS AN EFFICIENCY HIGHER THAN 64% GREATER THAN MINIMUM REQUIRED. REQUIRED EFFICIENCY FOR TABLE C403.5 COMPLIANCE IS 20.3 SEER. HP-2 - 18.1 SEER (COMPLIES) RECEIVED SEATTLE DPD STAMP Oct 18 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT Z O U Ln Z O U 0f O l.� H O Z Ln d D Y 0_ Q Z Ln X W l.� O Z O J (l O U 0f O L1_ 0 W >_W W Of Z W W m 0 Z Q Z_ Q Of (n 2 H I � I �SS/�NAL ti��1 0r4r 16' SCALE: 1/8" = 1'-0" PROJECT 9/ 2 2/ 2 0 2 2 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\MO.02 HVAC SCHEDULES.dwg Z O W W' U (n W 0 N Z zuz O (>n LLI W Q 0 PLOT DATE 9/22/2022 DESIGN DEVELOPMENT ❑ DRAWING DATE -- 13 COORDINATION DATE ® PERMIT DATE ❑ CONSTRUCTION DATE 13 AS BUILT DATE M U W N Of 00 0 O Q 0 U �� a V J [If 00 0 W LLj � ILL. Q J z_ m W � Z z � LLJ J Q IY U r- fT] o� I r� 3�0tpNLoO Zp) LCyQ �I^r- QNOwr0Q' oZ ,Mw C) LO w v�k ln�vL�i jXH Q J LL. O O Q Q i LJ ~ W °CS O o a W CL N 0 U Q N m � W g � HVAC SCHEDULES SCALE: AS -NOTED M0.01 XXX-XXXX f rs i* mob.-�'. f a P.M � �f�a� yr • i i mastercr, I I I/ A /-\ rl I A K SCALE: NTS 22-104507 Z O U H N Z O U D' O LL_ H O Z N 0_ Y Cif CD Z H N X W LL_ O Z O_ J d O U Cif LL_ 0 W _W Z O I- D_ 0f U N W 0 N z ZUZ O >in LL1 W Q 0 z PLOT DATE 9/22/2022 w RECEIVED �uST//v SEATTLE DPD STAMP Oct 18 2022 ��o of WAS tiy� a�7 om CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT o 4 e4s �wx 2' 8' �� :GISTE�� �SI�NAL of 4t 16 'aD SCALE: 1/8" = 1'-0" PNOJ CT 9/ 2 2/ 2 0 2 2 C:\Users\davisc\Desktop\General TI CAD Setup\ENGINEERING\CAD\KCFD20\Sheets\M2.01 HVAC PLAN.dwg DESIGN DEVELOPMENT ❑ DRAWING DATE -- 13 COORDINATION DATE ® PERMIT DATE ❑ CONSTRUCTION DATE 13 AS BUILT DATE m J U W N 00 IY CY) D O O >Q> U U)� a 00o W Ln� Q J z_ m Z J Ld J Q IY � U � rn J O I r, Lo Lo ��toNU0O Z p) ^ CI Q I r Q N�roOp�w 0 Z � `'r7 m Lo W ps wv�k CLo ln�vLL. jXH Q J LL. O F- Q Q � y LJ W L� O 0 o a w CL to o U C � U�m� w HVAC PLAN SCALE: AS -NOTED M2.01 XXX-XXXX 9/22/22, 2:40 PM https://waenergycodes.com/print project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW1 IY1 9odmFjX3N5c1 96b25pbmdfc2luZ2xlJTdDcGRfY2hnX3NwYWNIX2NvbmRpdGlvbmluZ... MECHANICAL COMPLIANCE SUMMARY 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2022 NEEA, All rights reserved Project & Applicant Information Project Title Twin Lakes Country Club - TI - 2018 WSEC For Building Department Use: Date: Sep 22, 2022 Project Address 3583 SW 320th Street Federal Way, WA 98023 Applicant Name Davis Cavanagh Applicant Phone 253-289-5102 Applicant Email davisc@emeraldaire.com For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Services General Building Cond. Floor 3,800 Type Area New Building Project Cond. Floor Area 3,800 General Project Types Change in Space Conditioning (Semi -heated converted to Fully or Addition Alteration Mechanical Single Zone Systems & Floors Above Grade I Conditioned) Mechanical Scope Equipment Scope p Compliance Method Not Selected Mechanical Project Description EXISTING BUILDING TENANT IMPROVEMENT, SCOPE ONLY APPLIES TO THE ADDITION OF TWO COOLING SYSTEMS USING SPLIT SYSTEM HEAT PUMPS, EACH SERVING ONE ZONE Economizer Equipment Project Type Mechanical Scope Exception(s) DOAS Ventilation Higher Equipment Efficiency Mechanical Compliance ? Applied. Provided? Efficiency Option Applied? Compliance Scope and Method Verification Change in Space Single Zone Systems & Yes No NA COMPLIES Conditioning Equipment Additional Efficiency Credits Included (AEC) Does building include occupancy classifications requiring No Does project include DOAS equipment? No DOAS? Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an No exception to TSPR? Scope & Space Conditioning CHANGE IN SPACE CONDITIONING - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category - Heat pump, unitary, thru-wall, SDHV Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) HP-2 Constant volume ASHRAE Standard 62.1 Other System Not provided, not required HP-1 Constant volume ASHRAE Standard 62.1 Other System Not provided, not required Air Systems & Equipment - Cooling System/ Equip ID q P Cooling System/Equip Type Specific Type Cooling Capacity per item Btu/h P ( ) AEC Efficiency Multiplier P Econo Exception Multiplier FL & PL P( ) Combined Efficiency Multiplier AEC & Econo P( ) Proposed Cooling Efficiency y CE Units Proposed Part Load Efficiency Y PL Units Efficiency Compliance Verification HP-1 Heat pump, air cooled Split system 22 1 0 1 20.5 SEER IEER COMPLIES HP-2 Heat pump, air cooled Split system 31 1 0 1 18.1 SEER IEER COMPLIES Air Systems & Equipment - Heating System /Equip ID Heating System/Equip Type Specific Type Heat Pump Heating Capacity (Btu/h) Cooling Capacity (Btu/h) AEC Efficiency Multiplier Proposed Heat Pump Heating Efficiency HPH Units Proposed Low OSA Temp Efficiency LTH Units Efficiency Compliance Verification HP-1 Heat pump, air cooled, heating Split system 28 21 1 10.0 HSPF COP COMPLIES HP-2 Heat pump, air cooled, heating Split system 33 18 1 9.6 HSPF COP COMPLIES https:Hwaenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW1 IY1 9odmFjX3N5c1 96b25pbmdfc2luZ2xlJTdDcGRfY2hnX3NwYWNIX2NvbmRpdGlvbmluZyZOZnY9bWVjX2h2... 1 /2 22-104507 9/22/22, 2:40 PM https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW11Y19odmFjX3N5c196b25pbmdfc2luZ2xlJTdDcGRfY2hnX3NwYWNIX2NvbmRpdGlvbmluZ... Air Systems & Equipment Details System/Equip ID Area(s) Served Location In Project Documents - Plan/Detail # HP-2 FITNESS M2.01 System/Equip ID for a single or multiple items?: Heating Section/Auxiliary Heating Type: Other source Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps HP-1 MAIN SHOP I M2.01 System/Equip ID for a single or multiple items?: Heating Section/Auxiliary Heating Type: Other source Economizer Compliance Method: Economizer not required WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(2) - Unitary and Applied Heat Pumps Proposed Low OSA Temp Efficiency: LTH Units: COP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(2) - Unitary and Applied Heat Pumps https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPW1 IY1 9odmFjX3N5c1 96b25pbmdfc2luZ2xlJTdDcGRfY2hnX3NwYWNIX2NvbmRpdGlvbmluZyZOZnY9bWVjX2h2... RECEIVED Oct 18 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT 2' 8' 0' 4' 1 SCALE: 1 /8" = 1'-0" 2/2 S EATTLE DPD STAMP Q 1) 6' PROJECT 9/22/2022 Setup\ENGINEERING\CAD\KCFD20\Sheets\M2.02 WSEC COMPLIANCE Z O U o' m Z O U Of 0 w I- O Z c� z U) X W w 0 Z 0 CL 0 U Cif O w 0 w 3 w Cif w w m O Z m 2 c� Z 3 Of 0 Z 0 U N w 0 N Z 0 W Of w Q 0 PLOT DATE 9/22/2022 ❑ DESIGN DEVELOPMENT DRAWING DATE -- 11 COORDINATION DATE ® PERMIT DATE ❑ CONSTRUCTION DATE 11 AS BUILT DATE m D J U W CV 0� 00 (10 °' ova "' O U �J a 00o W L0� Q J z_ m 6i z Z LLI J Q Of U C) rn Lfi I� mJ o I r u') � 30CDNLno zrn �..^a I �Q O Z M � W OOLOW04 � C14LL Q J W OU 0 ¢ Q � y i IWJ H Lw O o a Of 0- Q) o U C p� N LJ w g WSEC COMPLIANCE FORMS SCALE: AS —NOTED M2.02 C:\Users\davisc\Desktop\General TI CAD FORMS.dwg XXX—XXXX