Loading...
22-104677-MechanicalDrawing-10-12-2222-104677 1" schedule 40 metallic piping to new 199,900 btu exterior mounted water heater per UPC Table 1216.2(1) provide sediment trap at appliance IFGC 408 All new water piping shall be by separate permit Gas piping shall be WH protected from corrosion 15' `cns—cns—cas—cns—cns—cns—cns—c45' —cns—cns—cns—cns—cns—cns—cns— ^ Meier Existing 25 psi gas meter, install Support 1" gas piping I FGC 415 support 2 psi regulator at this location every 8' per UPC Table 1210.2.4.1 every 8' 415 Gas pipe shall be on pressure test at time of inspection , gage shall be in good working order. GAS PIPING PLAN RECEIVED Oct 25 2022 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT PERMIT SET W W � o = o PC o Z � y Ww O Q Q O � � 0 cM W W 0 O RADIANT Plumbing & Heating, Inc 4516S8'"St Tacoma, WA 98404 253-548-6723 License# RADIAPH874OF Sheet M-1 GAS PIPING Permit Drawings Date: 10/ 11 /2022 MNavieN THE LEADER IN CONDENSING TECHNOLOGY NPE-2 Series Tankless Water Heaters Premium Condensing Tankless Gas Water Heater • Certified design according to ANSI Z21.10.3 - CSA 4.3 latest standards for both indoor or outdoor installations (with optional Outdoor Vent Kit) • Compatible with 1/2" gas pipe up to a length of 24 ft* (*see Installation Manual for additional information) • Compatible with 2" PVC vent up to 75 ft** and 150 ft** using 3" PVC vent (**with no elbows) • Designed for use in Residential and Commercial applications (see below for available models and warranty terms) • Gas Input Ranges NPE-18OA2/S2 - 150,000 to 10,000 BTU/h NPE-210A2/S2 - 180,000 to 12,000 BTU/h NPE-240A2/S2 - 199,900 to 13,300 BTU/h NPE-150S2 120,000 to 18,000 BTU/h • Hot Water Flow Rate Capacity (*based on 350F temperature rise) NPE-18OA2/S2 8.4 GPM NPE-21OA2/S2 10.1 GPM NPE-240A2/S2 11.2 GPM NPE-150 S2 6.8 GPM TDR (Turn Down Ratio) up to15:1 • Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability • Buit-In - Advanced Multi -Lines Control Panel with setup wizard allows adjustment of temperature settings and displays of operating status} and error codes • CGOO fhil)(}OO If'i Flout -Technology- %2" models come included with built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide maximum comfort • INTELLIGENT Preheating - recognizes hot water usage patterns to intelligently provide hot water when needed (optional for "s" models) • Temperature Options - available temperature settings for Residential applications range from97°F up to 140*F with high temperature Commercial mode capable of up to 185°F • Ready -Link Cascade Compatible for up to 32 units for increased hot water production Common Vent Compatible - allows for cascade systems to use a single exhaust and/or intake pipe for up to 12 units with the use of the Common Vent Backflow Damper Collar Kit (n30014367A) • Compatible with Navifin (. Wi-Fi Control (nPBCM-As-001) • Freeze Protection - maintains normal operation during freezing ambient temperatures down to -5°F (standard on all models) • Uniform Energy Factor Ratings for NG and LP units NPE-18OA2/21OA2/24OA2 - 0.95 UEF NPE-180S2/21OS2/24OS2 - 0.96 UEF NPE-15OS2 - 0.93 UEF *** • Compatible with Natural Gas (NG) and Propane (LPG) (*** requires installation of included Field Conversion Kit by a qualified gas servicer) • Approved for Installations on Manufactured Homes • Optional NaviCirc Crossover Valve Compatible • Certified by CSA, NSF 5, AHRI, AB1953 CA Low Lead, SCAQMD (Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3% 02) • 15-Year Heat Exchanger and 5-Year Parts Warranty (Residential)**** 8-Year Heat Exchanger and 5-Year Parts Warranty (Commercial)**** (**** see Navien Limited Warranty) • Optional accessories are available (see below) Specification Sheet ll�. 6 Sleek Design Compatible with 2" PVC and 1/2"Gas Pipe r•avrer• Gas Type Recirclation/ Main/Sub Space Heating Flow Rate/Status Temperature Setting Combustion/Error Menu Button Up Button Back Button Down Button OK Button Power On/Off Button Built -In Control Panel with Diagnostics Indoor and Outdoor 'Intake Cap Venting Options "Coupling Li 2" Pipe Outdoor Vent Capes g Non -Di rect Vent (I rid oor) Non -Direct Vent (Outdoor) EENERGYSTNSFAR a Job Name: Location: Engineer: Wholesaler: Contractor: Model No.: Submitted to: ®o 0 Q° CondensateNeutralaer Remote Controller Plumb 009323 -Lad (3/4") Ready -Link 3"VettTermilatan (GXXX001 322 - Single Unit) OutdoorVent lGt External Pump Wire (30009323A-Lead Free) (GXXX001 324 - Up to Units) CommumcationCable (30025801A) (GXXX001319) Caps and Wall Flanges (30022717B) (30025812A - for Pipe Cover) (GXXX001 325 - Up to 16 Units) (GXXX000546) (GXXX3873B) 1-NPE2-SS-001-1.0 MNavieN THE LEADER IN CONDENSING TECHNOLOGY Premium Condensing Tankless Gas Water Heater NPE-180A2/ 210A2/240A2 SupplyConnections DescriptionAL Diameter A Airintake tin B Exhaust Gas Vent tin C Hot Water Outlet '/.in D Gas Inlet '/.In E Recirculation Inlet '/.In F Condensate Outlet 4,in G C°Id Waterinlet '/.in SupplyConnections SupplyConnections NPE-15092/ 180S2/210 S2/240S2 0�® 0�® 0�® 0�® 0�® SupplyConnections NPE-2 Series Tankless Water Heaters Specification Sheet Item NPE-150S2 NPE-180A2 NPE-180S2 NPE-210A2 NPE-210S2 NPE-240A2 NPE-240S2 Heat Capacity Natural Gas, 18,000-120,000 10,000-150,000 BTU/H 12,000-180,000 BTU/H 13,300-199,900 BTU/H (Input) Propane Gas BTU/H Uniform UEF (for NG & LP) 0.93 0.95 0.95 0.95 0.96 0.95 0.96 Energy Factor 35 T (19 °C) 6.8 GPM 8.4 GPM (32 Um) 10.1 GPM (38 Um) 11.2 GPM (42 Um) Temp Rise (25.8 Um) Flow Rate 45 T (25'C) 5.3 GPM 6.5 GPM (25 Um) 7.8 GPM (30 Um) 8.7 GPM (33 Um) (DHW) Temp Rise (20 Um) 67T(36°Q 3AGPM 4.3GPM 4.4GPM 5.1GPM 5.3GPM 5.6GPM 5.8GPM Temp Rise (13 Um) (16 Um) (17 Um) (19 Um) (20 Um) (21 Um) (22 Um) Dimensions 17.3 in (W) x 27A in (H) x 13.2 in (D) Weight 62lbs 73lbs 68lbs 77lbs 73lbs 77lbs 73lbs (28 kg) (33 kg) (31 kg) (35 kg) (33 kg) (35 kg) (33 kg) Installation Type Indoor or Outdoor Wall -Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure 3.5 in WC-10.5 in WC (from source) Propane Gas Supply Pressure 8 in WC-13in WC (from source) Natural Gas Manifold Pressure -0.04inWC -003inWC--0.55inWC -0.03 in WC - -0.76 in WC -0.03 in WC - -0.96 in WC (min-max) -0.40inWC Propane Gas Manifold Pressure -0.03inWC- _0.02inWC--0.55inWC -0.02 in WC - -0.76 in WC -0.02inWC--0.96inWC (min-max) -0.40inWC Minimum Flow Rate 0.5 GPM (1.9 Um), < 0.01 GPM (0.04 Um) option for"A2"models* Cold Water Inlet 3/4 in NPT Connection Hot Water 3/4 in NPT Sizes Outlet Gas Inlet 3/4 in NPT Main Supply 120VAC, 60Hz Power Supply Maximum Power 200 W (max 2 A), 350 W (max 4 A) with external pump connected Consumption Casing Cold Rolled Carbon Steel Materials Heat Primary Heat Exchanger: Stainless Steel Exchangers Secondary Heat Exchanger: Stainless Steel Exhaust 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel 2 in or 3 in Special Gas Vent Type BH (Class II, A/B/C) Venting Intake 2 in or 3 in PVC, CPVC, Approved Polypropylene and stainless steel 2 in or 3 in Special GasVentType BH (Class ll, A/B/C) Vent Clearances 0 in to combustibles High Elevation 10,100feetforbothNGorLPgas.PleaserefertoInstallationManualforadditionaldetailsandinstructions. Safety Devices FlameRod, APS, Ignition Operation Detedor,WaterTemperatureHigh Limit Switch, Exhaust Temperature HighLimitSensor, Power Surge Fuse, Burner High Limit Fuse, Vent Installation Detector (VID) *Available for"A2"models configured in an optional ComfortFlow recirculation mode. Energy consumption will increase when the system is configured for recirculation. Gas -fired, tankless, condensing, wall -mounted water heater(s) shall be direct vent NPE-2 Series models as manufactured by Navien, Inc. and are certified by CSA International to the latest edition ofANSI standard Z21.10.3/CSA 4.3. Water heater(s) shall have a 15(5) year limited Heat Exchanger warranty and 5(3) year limited Parts warranty (8(5) year Heat Exchanger and 5(3) year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed. (qty) NPE water heater(s) shall have a nominal flow rate capacity of GPM/GPH at °Frise with rated input of BTU/hr. Water heater(s) shall be vented with 2" Schedule 40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance not to exceed 75' (or equivalent) with each elbow equal to 8' of pipe length or 3" Schedule 40/80 PVC/CPVC, approved polypropylene and stainless steel vent pipe at a distance of 150' (or equivalent) with each elbow equal to 5' of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5" WC for natural gas and 8.0" to 13.0" WCfor propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4" inlet gas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallon for the NPE-150S2, 1. 0 gallon for the NPE-180A2 model (0. 7gallonsfor NPE-180S2 model),1.2 gallons for the NPE-21OA2/NPE-24OA2 models (0.7 and 0.9 gallons for NPE-21OS2 and NPE-240S2 models respectively), and a condensate collector. The NPE-180A2 model weighs 73 lbs (NPE-I80S2 weighs 68lbs), and the NPE-21OA2/NPE-24OA2 models weigh 771bs (NPE- 210S2 and NPE-240S2 weigh 731bs) and The NPE-150S2 weigh 62lbs. Unit(s) shall include features such as an adjustment for installations at high elevation, temperature lockout, and temperature options from 97-120°Fin 1 °F intervals and 120-140°F in 1 °F intervals. The unit(s) shall include additional temperature options of 140-185°F in 1 °Fintervals, for high temperature commercial applications. All NPE "A2"models shall include an internal circulation pump and 0.5-gallon buffer tank. The water heater(s) shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safety featuressuch as flame sensor system, high limitsensors, overheat prevention device, freeze protection mode, and fan motor rotation detector. Multi -system (cascade) applications that require 2 to 32 units shall be installed by connecting the units using cable only connections (Ready Link). The water heater(s) exceeds the energy efficiency requirements of ASHRAE 90.1-2010 and is listed by SCAQMD rule 1146.2 (Type 1) for Low NOx that complies with 14 ng/) or 20 ppm NOx requirements @ 3% 02. *Navien reserves the right to change specifications at any time without prior notice Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navienlnc.com 1-NPE2-SS-001-1.0