Loading...
18-101978-SFCITY OF 4s,. Federal Way Centererd c.n Opportun3#y June 13, 2018 Mark Barrett 2529 S 304th PI Federal Way, WA 98003 RE: Permit #18-101978-00-SF; BARRETT,1836 S 308th St, Federal Way Dear Mr. Barrett: CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com Economic Development The Public Works Department has reviewed the storm drainage and street frontage associated with your proposed single-family home and will continue review when the following items have been addressed: Please review the 2016 King County Surface Water Design Manual, Appendix C, and provide a summary of how each BMP relates to this site. While Mr. Poblete's letter discusses some of the BMP's, others are not addressed. If the home were located further back on the lot, could limited dispersion be provided in the front yard? Could C.2.10 Native Growth Protection Credit be applied? Could the applicant use a wheel strip driveway? Even if a BUT will not work for the entire lot, please provide BMP's for any amount of impervious area that can be handled onsite. A right-of-way permit will be required for any work within the public right-of-way on S 308t` Street, including driveway demolition, driveway construction, and utility connections. Please contact the permit desk at 253-835-2725 for further information. Please submit three revised site plans for further review. If calculations are required for the BMP's that are used, please include those as well. You may contact me at 253-835-2732 or at ann.dower@ci!yoffederalLALay.com if you have any questions. Sincerely, Ann Dower Senior Engineering Plans Reviewer AD:mt cc: Cole Elliott, P.E.; Development Services Manager pflad df 18-101978-00-SF \\CFWFILE I W pplications\CSDC\PROD\docs\save\ 151485_77881 _ 13110829.DOC ; 4k cIrr OF � M��V PERMIT _ PPLICATICN �E MAY 0 8 201 PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 Federal Way 253-835-2607 + FAX 253-835-2609 + permitcentelta�cityoffederalway.com MYOFF DERALDEVELOWAY A(�[T PUBLIC WORKS PERMIT NUMBER COMMU— . 1 () J Z ly— 5 F TARGET DATE SITE ADDRESS i � 2 (- 300 r �� 0 A,\-/ L? SUITE/UNIT # PROJECT VALUATION $ ZONING ASSESSOR'S TAX/PARCEL # '7 `, _5- 3 _ o ® f TYPE OF PERMIT BUILDING PLUMBING MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT PROJECT DESCRIPTION Detailed description of work to be included on this permit only NAME PRIMARY PHONE PROPERTY OWNER �y2 MAILING ADD$ESS� c� -n� K1l E-MAIL CI `a L-j �yIni8 ZIP O � � 19 I � NAME i� PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE FEDERAL WAY BUSINESS LICENSE # PRIMARY PH� A7-7, — NAME NfAnnib ADDRESS MAIL IT APPLICANT CI'�'Jt �� ci �_ S� Z , d� � _. [Uf FAX PROJECT CONTACT �- NAME ,/� ",,� A/ 4 IC 7-% PRIMARY PHONE MAI G ADD t7 -- 417 E L (The individual to receive and respond to all correspondence - CIT r.A VA e ^ AX concerning this application) PROJECT FINANCING NAME CYOWNER-FINANCED When value is $5, 000 or more (RCW 19.27.095) MAILING ADDRESS, CITY, STATE, ZIP PHONE I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental Iaws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city _a of this application. } SIGNATURE.--';�F DATE PRINT NAME: IMAAle N Bulletin #100 — January 29, 2016 Page 1 of 2 k:\Ilandouts\Perinit Application VALUE OF MECHANICAL WORK �T Cj Indicate how ma a each type of re to be instaIIed.or relgctlted as part of this ro* et, Do not include existin res to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETIS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (Commercial) BOILERS FURNACES �_ HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATI6N SYST DUCTING GAS PIPING WOODSTOVES PLUMBING MBING PERMIT Indicate how M"y of each Ulpe of re to be installed or relocated as part or this kn2hEt Do not include exzsU res to remain. BATHTUBS (­Tub/Shower Combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS �_ SINKS (Kitchen/Utility) WATER HEATERS (Electz'c) HOSE BIBBS SUMPS I WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ONPeROPERTY? PURVEYOR SEW/E`R PURVEYOR VALUE OF EXISTING IMPROVEMENTS / ' 0 WATT"ERR 0-��}1-�" `r/ `liter / / I l � 6 � ( / / IC. � i7 ,4 V F / „ EXISTING/PREVIOUS USE l r lte , � LOT SIZE )In Squaze Feet) ,y�, EXISTING FIRE SPRINKLER SYSTEM? ❑ Yes O No PROPOSED FIRE SUPPRESSION SYSTEM? ❑ Yes erNo RESIDENTIAL -NEW OR ADDITION AIRS -A DESCRIPTION (in Szuare feet) EXISTING PROPOSED 1 TOTAL FOR OFFICE USE cS -BASEMENT FIRST FLOOR (or Mobile Home) Yi-�� 2 3 2 Si'.CO-ND FLOO_ R 1 .3-7. . COVERED ENTRY DECK GARAGE 12' CARPORT ❑ OrTlil,,k (desrribo) Area Totals �^ EXISTING ESTIMATED SELLING PRICE $ �d li# OF BEDROOMS COMMERCIAL - NEW/ADDITION AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet q,--e Stories NEw-BUILDING ADDITION COMMERCIAL - REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Occupancy Group(s) Construction # of Additional Information Square Feet jXpe Stories TtiYVAL SU3 DING TENANT AREA ONLY PROJECT AREA ONLY Bulletin #100 - January 29, 2016 Page 2 of 2 k:\Handouts\Permit Application RESUBMITTED DRAINAGE ASSESSMENT JUN 21 2018 10C BARRETT SHORT PLAT CRY o� FEDERAL'Ngy COMMUNffy DEl/ELQ°MEET r Applicant: Mark Barrett Property Address: 1836 S 308t` St. Parcel Number: 7853600008 The property is located approximately 50 feet west of the intersection of S 308t` Street 0 and 19'5 Place S. The site address is 1836 S 308t' Street, Federal Way, WA 98003. The site is within the northwest quarter of Section 9, Township 24 N, Range 4 East, Willamette Meridian, King County, Washington. The rectangular -shaped property is approximately 0.21 acre (9,000 sq.ft.) in size and is zoned RM. There was an existing house on the property that was recently removed. Most of the remaining areas are landscaped with some mature trees. The ground is relatively flat, with a slight slope to the northeast corner of the property. Site soil is Alderwood gravelly sandy loam (AgB) as classified by the USDA Natural Resources Conservation Service. It is proposed to build a single-family residence on the lot. No frontage improvements are required. The combined total impervious surfaces will be 3,020 sq.ft., which will allow this site to fall under the Simplified Drainage Review requirement. Per Item 5 of Section C.1.3 of the 2016 KCSWDM, this project falls under the Small Lot BW Requirements. The following BMPs were considered in order as they are listed in Section C.1.3.1 of the manual: Full Dispersion — Due to the size of the lot, the required native vegetated flowpath is not available. This BMP is therefore infeasible. Full Infiltration — The septic designer has stated that the site soils are not acceptable for infiltration. This BMP is therefore not feasible. Limited Infiltration — As previously mentioned, the septic designer has indicated that the site soils are not acceptable for infiltration, therefore this BUT is not feasible. Bioretention — Bioretention is an infiltration device, therefore, this BUT is not feasible. Furthermore due to site soils, a bioretention cell will take up too much space and will necessitate removal of trees. The standing water in the bioretention cell may also cause down gradient flooding. Permeable Pavement — Permeable pavement is an infiltration device, therefore, due to site soils, this BUT is not feasible. a �.s O tCa V co A ,,a Basic Dispersion — Basic dispersion is used for the proposed driveway and concrete entry way. Basic Dispersion was also considered for the roof area, but is deemed infeasible for the following reasons: 1. Splash block will require a flowpath of 50 feet, which is not available. 2. Trenches will require 25 feet of vegetated flow path. We considered moving the house further south, however, this will create a longer driveway (therefore more impervious surface), which will also require a BMP, which in turn will eat up more flowpath area. In addition, the house cannot be moved too far south because the tree protection zone will be disturbed. Due to lack of available space, this BMP is not feasible. 3. Sheet flow will not be feasible since together with the driveway dispersion, required separation of flowpath and flowpath width, there will simply not be enough space to provide this BMP. Per Item 5 of Section C.1.3.1 BMPs must be implemented to at least 10% of the sitellot. The driveway/concrete entry way area being dispersed is equal to 903 sq.ft., which is greater than 10% of the lot area. This project has therefore met the Small Site BMP requirements. However, the following BMP were also considered: Reduced Impervious Surface Credit — There are several ways of applying this BMP. The wheel strip driveway was suggested, however, this application is more suitable for long one -lane driveways. This application is not practical for this project since the driveway is short, and since it is a 20-foot driveway meant for two cars, four wheel strips will be required. This may cause maintenance issues since cars will end up driving on the vegetated portion of the driveway, and also from an aesthetics standpoint, a wheel strip driveway for this lot will not be very pleasing. We have therefore chosen to use the restricted footprint option. This project is zoned RM, which does not have coverage limitations, therefore we used 4,000 sq.ft. as the limit. The total impervious surface proposed is 3,020 sq.ft., therefore 980 sq.ft can be credited. Native Growth Retention Credit — It is proposed to retain vegetation within an area of 3,218 sq.ft. Per Section C.2.10, for every 3.5 sq.ft. of retention area, 1 sq.ft. of targeted area may be credited. An area of 919 sq.ft. may therefore be credited. As previously mentioned, under the Small Lot BMP requirements, only 10 percent of the lot need be provided with a BMP. By dispersing the driveway/concrete entry way alone, the requirement has already been meet. If the Reduced Impervious Surface Credit and Native Growth Retafton Credit are also applied, the total percentage of the lot being mitigated is equal to 31% ((903 + 980 + 919)/9,000). Since the Reduced Impervious Surface and Native Growth Retention Credits are above the requirements, we believe they should not be required to be recorded, and was only considered to show that the requirement will be exceeded. Perforated pipe connection will be provided for the roof drain. Construction will be limited to only those associated with the home building. Erosion and sediment control measure will include stabilized construction entrances, ground cover and silt fencing. CIT Federal Way DRAINAGE AND EROSION CONTROL PLAN RECOMMENDED CONSTRUCTION SEQUENCE L Hold the pre -construction meeting, if required 2. Post sign with name and phone number of TESC supervisor (may be consolidated with the required notice of construction sign). 3. Flag or fence clearing limits. 4. Grade and install construction entrance. 5. Install perimeter protection. 6. Grade and stabilize construction roads. 7. Construct surface water controls simultaneously with clearing and grading for project development. Do not allow sediment -laden water to enter the perforated pipe connection. 8. Maintain erosion control measures in accordance with the City of Federal Way standards and manufacturer's recommendations. 9. Relocate erosion control measures, or install new measures so that as site conditions chance, the erosion and sediment control is always in accordance with the City of Federal Way Erosion and Sedimentation Control Standards. 10. Cover all areas that will be unworked for more than seven days during the dry season or two days during the wet season with straw, wood fiber mulch, compost. plastic sheeting, or equivalent. 11. Stabilize all areas within seven days of reaching Final grade. 12. Seed, sod, stabilize, or cover any areas to remain unworked for more than 30 days- 13. Upon completion of the project; connect roof drain to perforated pipe connection, stabilize all disturbed areas and remove BMPs if appropriate. 2�20.1LF�t+3"r�CONC L@� 1-84% —SSMH r S 308TH ST. RIM = 179.00� �') ROCK CONSTRUCTION I_E. = 164.4,4 ENTRANCE 15_, 8" CONC,-E,W IMPERVIOUS AREA LIST: EXISTING IMPERVIOUS (T❑ BE REMOVED CONCRETE PADS 174 S.F. .NEW IMPERVIOUS AREA HOUSE FOOT PRINT 2,116 S.F, DRIVEWAY 876 S.F, CONCRETE PAD 28 S.F. EX_ HOUSE 24" NCE CORNER J 6' s- � -\ EX- SSS TO BE,- REUSED 34.8LF 12 ,,'[`o CONIC @ 0.19% rEX. W.M. n _ WIN. • . GATE L TO BE 20" 8SBL REMOVED �° o ] T a LIMITS ` EX, CONC- I Td BE REMOVED I -JLn I W/; IN PROPERTY I 6' CHAIN LO NEW HOUSE ° I LINK �� F.F.E.=180.5± I O O CIO o — — o ` o Z n0) I I TREE TO BE REMOVED 03 I, FENCE CORNER 1.3' W. BY 0.5' N. } 1w - i 17". ��w * } 2' X: 10' / LEVEL TR NH 1. W/,PE`F ATED WIPE .(SEE DTL.) 10 VEGETATED FLO PATH - 1 C SSMH —RIM = 174.01! " I.E. = 160.4 I.E. = 16 0. 74 CB — TYPE' I \�:I, CONIC E, RIM � 174.31�Q'r,I.E. = 172. 9 .E. = 17�.5 r 1 FULL OF DIRT FULL OF DI CLEARING LIMITS A ` SILT FENCE TREE PROTECTION ZONE. NO DISTURBANCE I SOUTH OF THIS LINE 2.5' HIGH MAX. R TIE WALL ,? 0„ 4 CPO /I 5.5' CHAIN LINK J �' _ �`V, 1 inch = 20 ft. `5' BSBL 60.',8' y' y. CP' N89°50'17"W 106,13= FIN. D, 3/4' NOTE: 1. EXISTING MAILBOX AND NEWSPAPER BOX SERVES THE HOUSE ACROSS THE STREET. NEW MAILBOX TO BE ADDED TO SERVE THIS PROPERTY. 2. NO NEW TREE UNITS REQUIRED. SEE TREE RETENTION PLAN. STAMP NOT VALID UNLESS SIGNED & DATED DATUM: NGVD 29 SITE BENCHMARK: EX. WATER METER LID EL.= 177.39 APPLICANT: MARK BARRETT AND KELLY BARRETT 2529 S 304TH ST., FEDERAL WAY, WA D D ;a 0 m 253 988-3482 ��K m PROJECT PARCEL NUMBER: 785360-0008 n M PROJECT ADDRESS: 1836 S 308TH ST. FEDERAL WAY, LEGAL DESCRIPTION: THE WEST 60 FEET OF THE NORTH OF LOTS 1 AND 2, SOLANO H Cct Oa Z -a ACCORDING TO PLAT RECORD( OD DkN W 00 VOLUME 30 OF PLATS, PAGE KING COUNTY, WASHINGTON mid-y(p O OD 00 SECTION/TOWNSHIP/RANGE: NW 9-21N-04ERECE TOTAL SITE AREA: 9,000 S.F. 30 CUT: 0 CU.YD. CITY OFFE[ COMMUNITY Di FILL: 15 CU.YD 785360-0008 MARK AND KELLY BARRETT 1836 S 308TH ST. FEDERAL WAY, WA 98003 I Engineering 20' Sheet 2 of Permit Number: Parcel Number: Applicant Name: Site Address: Scale: 1" _ CITY OF =a , Federal Wa v_ y SITE PLAN RANDOM FILL a a" MIN. 18° MIN. a >�• ' I �— 24" MIN. --+� TRENCH X-SECTION NTS 2.20. , L.r- 8" CCNC L� 1.84% SSM H S 308TH ST. -.RIM 179.OQ NEW 20 WIDE I.E. - 164.4 k ` CONC. ,DRIVEWAY_ 8,,..00NC�E,W . ......1.5". 24� l FILTER FABRIC 6" PERFORATED PIPE 1 z'" -' WASHED ROCK SLOPE 6'S CORNER . ENCE GATE- 4 TO BE REMOVED °4 ---� TO ROAD DRAINAGE SYSTEM 2' x 10' LEVEL TRENCH w!PERFORATED PIPE PLAN VIEW OF ROOF NTS PERFORATED PIPE CONNECTION NTS IMPERVIOUS AREA LIST: EXISTING IMPERVIOUS (TO BE REMOV CONCRETE PADS 174 S.F. NEW IMPERVIOUS AREA HOUSE FOOT PRINT 2,116 S.F. DRIVEWAY 876 S.F. CONCRETE PAD 28 S.F. o d II EX. SSS TO BE,, -REUSED I"EX.i W-1M: ROOF LINE I 4 I m I 6' CHAIN �ml LINK o I� 0 G EX. HOUSE { I w TREE TO BE, REMOVEDI Co FENCE CORNER____ 1 .3' W. B Y 0.5' N . v rs M r-L �I d �f SEE 6'TE 11 N 89'50 17"W ACP{ LLLFFF r--' 14 20" 36"' I 'EX. CONC.- TO BE REMOVED W/IIN PROPERTY i INEW HOUSE F'IF. E. =180. 5± a I d 34.8L:F 12 CONC @ .0:19% 0 \ ROOF DR INY i TYP. I. 2-' x 1 G' / LEVEL TR tyCH l: W/,PETRF ATED -PIPE :(:SEE DTL.) 10VEGETATED FLO PATH i 00.00 _ I / r70G� Pow 00 a of 1 0- G� z l \ I (D 124 F I78_ TREE PROTECTION 2.5' HIGH MAX. ZONE R TIE WALL . 20 F � 34 o 5.5' CHAIN LINK I 20" F 20 ft~ `5' BSBL 60, 1�8" F T N89'50'177 10"0' 3 /4" 1] waill C8 TYPE C SSMH RIM = 174.01' I.E. 160.40� I.E. = 160.74 8" CONIC E, W, RIM = 174.31 10 »1 I.E. = 172.59 I.E. 172.5- FULL OF DIRT FULL OF DIR ! NOTE: 1. EXISTING MAILBOX AND NEWSPAPER BOX SERVES THE HOUSE ACROSS THE STREET, NEW MAILBOX TO BE ADDED TO SERVE THIS PROPERTY. 2. NO TREE NEW TREE UNITS REQUIRED. SEE DATUM: NGVD 29 *A SITE BENCHMARK: EX. WATER METER LID p -0 D EL.= 177.39 D ;U p m mC_� APPLICANT: MARK BARRETT AND KELLY BARRETT K _ 2529 S 304TH ST., FEDERAL WAY, WA n U) —I (253) 988-3482 -i (n PROJECT PARCEL NUMBER: 785360-0008 PROJECT ADDRESS: 1836 S 308TH ST. FEDERAL WAY 00,> Z 1 —' �;�cD aa ao C4 LEGAL DESCRIPTION: THE WEST 60 FEET OF THE NORTF CO Uj O OF LOTS 1 AND 2, SOLANO F m M ACCORDING TO PLAT RECORD O -I VOLUME 30 OF PLATS, PAGE co 00 KING COUNTY, WAqIp660N �1 E 3 Q. SECTION/TOWNSHIP/RANGE: NW 9-21N-04E TOTAL SITE AREA: 9,000 S.F. MAY 0 8 CD Permit Number: Parcel Number: 785360— 0008 Applicant Name: MARK AND KELLY BARRETT En ineerin CITY OF FEDEI Site Address:1836 S 308TH ST. FEDERAL WAY, WA 98003 Scale: l" =g 20' SheTMWNrr v EV