Loading...
16-101157CITY OF 1. Federal Way CITY HALL 33325 8th Avenue South Federal Way, WA 98003-6325 (253) 835-7000 wwwcityoffederalway. com Jim Ferrell, Mayor Mr. Joe Borrelli April 5, 2016 4326 SW 307th Street FILE Federal Way, WA 98023 Re: Files 16-101157-00-AU and 16-101146-00-SF; PLANNING DIVISION TECHNICAL REVIEW Borrelli Accessory Dwelling Unit; 4326 SW 307th Street, Federal Way Dear Mr. Borrelli: The Department of Community Development has completed review of the Accessory Dwelling Unit (ADU) application submitted to the city on March 7, 2016. The ADU application cannot be approved as it does not meet applicable zoning regulations. FINDINGS OF FACT ON ADU The ADU cannot be approved as discussed in findings 1 - 3 below. The following findings are based on site, floor, and elevation plans by Grimit Architecture received with the ADU application on March 7, 2016. Proposal— The applicant proposes to construct a detached two-story garage, which contains an ADU on the second floor, above the first floor garage. The detached structure is proposed at 4326 SW 307th Street, Federal Way. The subject property is currently developed with a single-family residence. 2. Zoning— The subject property is a 1.7-acre (73,418 square foot) lot located within a single-family low - density residential comprehensive plan designation and Suburban Estate (SE) zoning designation. 3. Minimum Lot Si.Ze — The subject property is approximately 1.7-acres in size. The minimum lot size for an accessory dwelling unit use within the SE zone is five -acres. As the subject property does not meet the five -acre minimum lot size requirement, the ADU cannot be approved. Specifically, the ADU zone use chart, Federal Way Revised Code (FWRC) 19.195.180 note 1 states in part, "minimum lot size forADU's is based upon the minimum lot side for the existing primary dwelling unit as set forth in FWRC 19.195.010." The zone use chart FWRC 19.195.010 for a detached dwelling unit requires a five -acre minimum lot size. The existing single-family residence on the subject property is considered a permitted use as it meets the buildable lot standard of FWRC 19.105.010, which code section permits as an exception (a detached dwelling unit on a lot or parcel regardless of the size of the lot), subject to other requirements of this section. However, the buildable lot standard does not apply for an ADU. In light of the fact that the city cannot authorize an ADU at the subject property, you may be able to construct a two-story detached accessory structure that does not meeting the definition of an ADU; provided, the Planning Division comments below are adequately addressed prior to issuance of the building permit. The lot coverage standard discussed below is a major issue that needs to be resolved. Mr. Joe Borrelli Page 2 April 5, 2016 4. The owner would need to provide the city with a notarized and recorded affidavit, certifying that the detached structure will not be used or occupied as an ADU. The form and content of the affidavit would need to be reviewed and approved by the'city prior to recording this document at King County. 5. The detached building cannot contain all of the,elements of an ADU, which by FWRC definition include: permanent provisions for living, sleeping, cooking, and sanitation. The building as proposed does not show a kitchen on the floor plan, so technically it is not an ADU as proposed. Detached Bmildrnrg Sibs — Pursuant to FWRC 19,265.010, both the total gross floor area and footprint of an accessory building must be less than the total gross floor area and footprint of the principal building on the subject property, respectively. The primary residence on the property is 3,120 square feet in size as noted on the site plan. The proposed size/Eloor area of the two-story detached structure is identified as 3,094 square feet on the submitted plans. However, further information and clarification of plans, and clarification of proposed floor area of the two-story detached structure is needed to verify the actual size of the proposed detached structure. Please advise how the square footages of the two floors are different sizes on the submitted (square footage), so we can confirm the total gross floor area is smaller than the primary residence. 6. Required Yards & Height —As depicted on the site plan, the proposed new two-story detached structure and associated improvements, including the stairway, meet the required 30-foot front yard, and 10-foot side and rear yard setbacks. The applicant would need to provide additional information and details regarding the proposed building height in order to determine compliance with the maximum 30-foot building height standard. The building height calculation would need to be depicted on plans in accordance with FWRC definitions of Height of St wafire and Average Building Elevation. The building height is not correctly depicted or calculated on the submitted plans. 7. Lot Coverage —The site plan as proposed exceeds the maximum 10 percent allowable lot coverage standards of the zone use chart FWRC 19.195.010 and cannot be approved. The calculation shown on the site plan does not meet applicable code requirements and needs to be revised to meet the lot coverage standards in the FWRC. It appears that required revisions to the lot coverage calculations that reflect proposed site improvements will result in the site plan exceeding the 10 percent maximum coverage. Specifically, pervious pavement as proposed is counted at a rate of 50 percent coverage, similar to grass grid pavers as allowed in FWRC 19.110.020(2). Therefore, the 2,175 square feet of pervious pavement would count as 1,088 square feet of impervious area. The addition of 1,088 square feet of impervious surface would result in the site exceeding the 10 percent maximum lot coverage. In addition, we need to see a more detailed site plan, specifying all the sizes of all impervious areas, including gravel, driveways, decks, structures, etc. in order to further verify the lot coverage. In order to approve a lot coverage exceeding 10 percent as allowed in FWRC 19.195.010, a variance land use application would be required. There are two different potential applicable variance processes as summarized below. In summary, a Process III administrative variance could be requested to permit up to 12.5 percent lot coverage (25 percent of the measurable standard) rather than the code required 10 percent maximum coverage. This process III variance application requires an application fee, public notice, and.a decision Doc. I.D. 72899 FL #1G-101157-00-AU Mr. Joe Borrelli Page 3 April 5, 2016 by the Community Development Director based on the criteria of FWRC 19.45.030. The burden of proof for meeting the variance criteria is on the applicant. In summary, a Process IV variance application could be requested to permit more than 12.5 percent lot coverage. A process IV application requires an application fee, public notice, public hearing, and decision by the Hearing Examiner. The Hearing Examiner is required to review any process IV variance application based on the criteria of FWRC 19,45.030. The burden of proof for meeting the variance criteria is on the applicant. Under this process IV scenario only, the applicant could also request a variance to the minimum lot size for an ADU. If you would like further information on the Process III or Process IV variance, I would be glad to discuss this with you and provide you with further information. If you will be pursuing one of these options, you will need further information from city staff as the information above is only a summary of the variance process and requirements. 8. Water & Sewer— Water and sewer connections would require approval by Lakehaven or Tacoma Utility District. 9. Other Department and Agency Review —The proposal will need to meet all applicable requirements of the Building Division and other agencies including, but not limited to, the South King County Fire & Rescue. BUILDING PERMIT REQUIRED This correspondence does not constitute building permit approval. Comments numbers 4 —10 above must be adequately addressed in order for the Planning Division approval of the building permit application #16- 101146-00-SF. Additional building code regulations apply to the proposal, and will be identified by the Building Division. CLOSING All code references above can be found in the FWRC at www.codepublishing.com/WA/FederalWay/. If you have any questions regarding this correspondence, please contact me at 253-835-2652, or jirn.harris@cityoffederalway.com. Sincerely, J2" v -"1 -:s- City Planner Enc: Variance and Process IV Handouts C Isaac Conlen, Planning Manager Peter Lawrence, Building Plans Examiner Kevin Peterson, Engineering Plans Reviewer, Public Works Development Services Michael Grimit, 516 Wana Wana Place NE, Tacoma, WA 98422-1732 File #16-101157-00-AU Doc. I.D. 72899 r'• �r N 00'00'00' E 6OZ78' I TOP OF WALL EL-125.24' GARAGE I Ila GftX4'- GRAVEL POf9Eit c NX FOR Z aox Msrrt l-f tt- f'PM KvcfZ 112 1 I WA L40QWAY Jll a' _ I JOB 4 SITE•TOPOGRAPHY AND BUILDING PLAN, TREE REMOVAL AND RETENSION PLAN STORM DRAINAGE PLAN r I� F Borrelli Garage, Storage & ADU ZONING/ SITE DATA Federal Way CODE REF. i CLASSIFICATION SIZE-w iSIZE-d SF AREA ALLOWED Parcel Number- King County 112103-9059 120 fe,l 615-86 feet 73,418 mg k.7 Auas') Pre-exiOng condition Zoning per the City of Federal Way (SE) Suburban Estate 120 feel 61518 feet 73,4la sf ' 1.7 Acresi 5 Acres minimum (SE) Suburban Estate Lot Coverage-10% 73,418sf 'x.10 .7.342si Existing Home Size Footprint 42 Feel 35 fail 15124W 1608 sf I1608 Proposed Garage Footprint 45 feel '35 reel 1575 � sf ALLOWED Existing Home Size total Basement+ Mein Floor 16H +1512= 3,120 sf Existing garage Site total Sasemedt Garage + IL,derground 240 +720= 960 sl �Propo3adGaragcoGlal Garaga +SWragP.lADLI 1575+1509- 3.084sf Existing plus proposed total Ex,sling 4.005 sf f PropasNJ 3.084 sf 3,0B4 sf < 4008 sf ALLOWED 9*vng Imperviolrs building area 1,608 house 080 garge 2.568 sf Existing frn"Ious gravel L paver area 3.021 sf PropC frnNrvlaus area Garage Only d6jaway Pervious Carr, (Pervious = 2.175 sq 1.575 sf 7.164 sf t$E! 7o ung Lot Coverage-10°/i I 7.342 sf, 7164 sf ALLOWED f1687omilm Height Calculation 30 feel max. F.ErA Ekemtion' 103.75l0 111.13 7.382=3.69+ 103-75= 107.44 North Ele6,aVan' 111.13 to 115.07 3.942=1.97+ 111.13= 113.1 South Elevation 103.75 to 105.78 2.032=1.015+ 103.75= 104.765 West Elevation 105.78 to,115.07 •9_292=4.645+ 105.78= 11 OA25. Total 435.7514 Average Grade Assume 109.00 for drawing 10893 BuildingHeighFFF113.5+12fL+8fL+58 138A- ;109= 29.6feet <30feet ALLOWED y {xl I N� I L 1 AWN r. 7 OVERALL SITE PLAN SCALE 1"= 20 FEET 1 NW LL U W t— F- 0,_ 1 Urn (U/�// Q 0 LL FJN Q �Qm FXZm F- c73a CT <H Z: rn UfOQ J z W �W W >� r1► z [n M Fw- 1-- 0 <r aorn ( CO V J co Qw } J �_ JOQ W D coW OO/�MW ITLL RECEIV MAR 0 7 201 DESIGn M ' OFrFEDi=RAL c 1 : _CD AY 4'-sN 6'-0" N s'•o- N 6'-0„ N 5,,¢., N 3,-0. N r 6014 6014 3040 IU I m i =� Ncn 0 m I m 1 I P, T v DORMER PLAN oil 0 N N ' I Z fe o O 1i N I --i li ' y i II r N 80 m O ti A i o ;o ?� o j Z 6-a 7!s" 2'-7 11z 7'-2 1 I ► �o o t �• D I z ; 0 c (V � i m M I:1 co co30i0 Z ro O N 0 r x O m ;m �6'-11112" 9-7' - - �4014 �'-• 4014 3040 I r "a11 4'-0" N 5'-9` N a'-o Nz'-0 ► 3'•(r H YiCr ►1 4'•411 - Vr- N 10'-4. STORAGE & ADU FLOOR PLAN SCALE 1/8"=V-0" R c om 9 z z � O I UP 1 i l 'm 3010 GARAGE FLOOR PLAN 2 J J Z W W LIJ / I L Z VJ `M a 1- 0 M (A Q JW� LL J � J wOW 113�(D Occ)ww mew tECEIVED IAR 07 Z016 9: No BY' OF FFDE AL Wt C-PIS I N N r VI i CD —/}.h , \V m IT 00 U N N >tJ.I AD U FLOOR 2N D FLOOR SCALE 1 /4"=1'-0" u I 1 ,, CD r l 16-11 1 \r. 4014 4014 PLAN— '-8H 4'-0" 51-911 --- 4'-0" — '-011 19 17'-511 lV 0 N F _ 6 n _ o O4 x co c� QO C2 m 6'-4 7/8" C-7 00 C) V0cv) M NO T r` 0 M 35'-0'1 ~6'-11 1 /2" 7'-2 1 cn D O z I 3040 3'-011 3'-0" - 4'-411 7'-311 k _ 10'-411 I. O 1 3 J L) r W ai w > rW V Z M a�00 o� M U J } /Q//WW I..L L Lij LL J0Q w�W O off° m m q- LL R CEIVED, MAR 07 2016 CITE O FED �"NA,Y CDs 30816 IF 1 i _��. _ ._� - -1 _. ��. .._ 'L ~ -.. � - yl �-� •��f =_ - tit,---� }-I NORTH ELEVATION i L _ EAST EI EVATii7N- SOUTH ELEVATION 0 r � L N W w zm — c) ~� Lu QLUuj W J J J0Q W� � W O O cci W i m m'TW ECEIV 07 2016 OF FE—,QFVL W Orbs 20216 v8 36'-0" 6056 4036 •�{ 3270 —-.----•�7. . , •... µ: �l - I � I I smo solo UP � 111 p z $ n 2670 > go x� i I I 2666 -- 3630 3040 2018 I li �If EXISTING MAIN FLOOR PLAN SCALE 1 /8"=1'0" 36'-0" 8036 :Wo '263A 3066 '1 .x 0266 a268 D ❑ I I 1 4 v r 3036 3666 3668 2366 ❑ 36.-0,, EXISTING DAYLIGHT BASEMENT FLOOR PLAN SCALE 1 /8"=1'-0" 47 J J Z CwC co co w W Z VJ — M Q M co Q w } J OwC=� -� O Q �coQ 0 Occ)w m m"Tw RECEIVED MAR 07 2U16 OTT Of FEDERAL WAY CD5 DESIGN BY: mpg 30B 4E RECEIVED 41kMAR 0 7 2016 DEPARTMENT OF COMMUNITY DEVELOPMENT Federal W Avenue South Federal Way, WA 98003 CITY OF40'::tt=;P CITY OF FEDERAL NAY 253-835-2607; Fax 253-835-2609 CDS ►vryvw,citvoffederalway.c rn Federal Way FILE # ACCESSORY DWELLING UNIT (ADU) FEE: Contact the Permit Center at 253-835-2607, or ermitcente ci offederalway.corn sF RELATED FILE #s: r �� Address: 0 Daytime Phone: (EZ2�2) I�o?2 ?;4QS Tax Parcel#: rr4 Zoning: �J Lot Size in Square Feet: ST Type of ADU: ❑ Attached V16etached Is this a: VNew ADU ❑ Existing ADU Existing ADU was: ❑ Approved by King County (Provide a copy of the permit.) ❑ Other Construction of existing ADU completed in 19__/20 Construction of existing residence completed in 19^/20_ Which is the owner occupied unit: L>1rimary Dwelling Unit or ❑ ADU Number of square feet: Sf Primary Dwelling Unit 9 r!; �wo ADU Provide the following information: W-'Lakehaven Utility District Water & Sewer Certificates of Approval for the New ADU p�IM g County ❑ Kin Coun Public Health Department Approval (if septic) V-4A 61 IT *#Veating Type: "lectric ❑ Gas ❑ Other ❑ Electrical Capacity: Primary Dwelling Unit ADU ❑ Letter of Application & Deed Restriction (attach) ADU FLOOR PLAN DRAWINGS (Provide the following; refer to page 3 for an example.) P'Floor plan of the primary dwelling unit and the ADU fi'Plumbing (existing & proposed) P'Mechanical — HeatingNentilation/Air Conditioning (existing & proposed) ff—Entrances of primary dwelling unit and ADU (existing & proposed) 20'Ceiling Heights/Room Sizes for ADU 2-Elevation of the proposed ADU with the primary dwelling unit Bulletin #049 — December 21, 2015 Page 1 of 3 k:\I-Iandouts\ADU Application ADU SITE PLAN DRAWINGS (Provide the following; refer to page 3 for an example.) cale/north arrow ?"'Lot dimensions �r_Street/driveway location C'Primary dwelling unit ff ADU footprint (if detached) O'Building setbacks from property line H" Location of utilities & easements N Show location of three on -site parking stalls P"'Locate the entrance of the primary dwelling unit and the ADU a"'Calculate the total impervious surfaces coverage for the site (Include the existing and proposed roof area, driveway, patios, and walkways.) ❑ Other Al - DISCLAIMER: I certify under penalty of perjury that the information furnished by me is true and correct to the best of my knowledge and further, that I am authorized by the owner of the above premises to perform the work for which the permit application is made. rl ,,signature of Applicant Date WAIVER: Approval of the ADU Land Use Application does not constitute approval of the building permit. Application and approval of the building permit is a separate process. OFFICE USE ONLY ❑ ADU Status: ❑ Legal Nonconforming per FWRC 19.30.140 ❑ New ADU ❑ Assigned Address of ADU ❑ Deed Restriction/Letter of Application Rec'd ❑ Recording Number ❑ Other Approved by Date ❑ Conditions of Approval Bulletin #049 — December 21, 2015 Page 2 of 3 k:\Handouts\ADU Application