Loading...
07-101627FILE CITY OF L Federal Way May 2, 2007 Shane Smith Sprint/Nextel 2465 8th Avenue North Seattle, WA 98109 CITY HALL 33325 8th Avenue South Mailing Address: PO Box 9718 Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com Re: File #07-101627-00-PC, PREAPPLICATION CONFERENCE SUMMARY Sprint/Nextel Cabinet @ 21st Avenue SW & SW 325`h Place, Federal Way Dear Mr. Smith: Thank you for participating in the preapplication conference with the City of Federal Way's Development Review Committee (DRC) held April 26, 2007. We hope that the information discussed at that meeting was helpful in understanding the general requirements for your project as submitted. This letter summarizes comments given to you at the meeting by the members of the DRC. The members who reviewed your project and provided comments include staff from the City's Planning and Building Divisions and Public Works Department, and representatives from Lakehaven Utility District and South King Fire and Rescue. Some sections of the Federal Way City Code (FWCC) and relevant information handouts are enclosed with this letter. Please be advised, this letter does not represent all applicable codes. In preparing your formal application, please refer to the complete FWCC and other relevant codes for all additional requirements that may apply to your project. The key contact for your project is Laura Kim, 253-835-2641, laura.kim@cityoffederalway.com. For specific technical questions about your project, please contact the appropriate DRC representative as listed below. Otherwise, any general questions about the pre -application and permitting process can be referred to your key contact. PROJECT DESCRIPTION Remove existing cabinets and replace them with new larger cabinets and replace existing antennas. MAJOR ISSUES Outlined below is a summary of the major issues of your project based on the plans and information submitted for preapplication review. These issues can change due to modifications and revisions in the plans. These major issues only represent comments that the DRC consider most significant.to your project and do not include the majority of the comments provided. The major issues section is only provided as a means to highlight critical requirements or issues. Please be sure to read the entire department comments made in the next section of this letter. • Planning Division All equipment cabinets must not be greater than 48 square feet total. Public Works Development Services Division Structures of this size (over 119 square feet) are not permitted within the public right-of-way. Mr. Smith Page 2 May 2, 2007 DEPARTMENT COMMENTS Outlined below are the comments made by the representatives of each department present at the pre - application conference. Each section should be read thoroughly. If you have questions, please contact the representative listed for that section. PLANNING DIVISION (Laura Kim, 253-835-2641, laura.kim@cityoffederalway.com) Review Process The project would qualify for a Land Use Process III including an environmental review. A State Environmental Policy Act (SEPA) Checklist will be required at the time of submittal of formal application. The City will then issue an environmental threshold determination. All property owners and occupants within 300 feet of the site must be notified of that decision. The notification includes a 14-day comment and 14 day appeal period. Project Siting In proposing a PWSF in a particular location, the applicant shall analyze the feasibility of locating the PWSF in each higher priority location and/or zone that is not being proposed. The orders of preferences are as follows: 1. BPA trail 2. Existing broadcast, relay and transmission towers 3. Publicly used structures 4. Appropriate business, commercial and city center zoned sites 5. Appropriate public rights -of -way The applicant must explain why the applicant can't co -locate on an existing tower, regardless of the existing site, if within a one mile radius. Proposal indicates that the PWSF will be in an appropriate right-of-way, 325`h and 21" Avenue, which are principal arterial streets. Development Standards ■ The PWSF shall be either a micro cell or a minor facility. • Maximum size of antennas to be located on existing structures in a public right-of-way shall be two feet in diameter for parabolic antennas, eight feet in height for panel antennas, and 15 feet in height for whip antennas. • The combined antennas may not exceed 15 feet above the existing structure, plus the height of the proposed antennas. • The antennas shall be mounted on the structure so that they are located and designed to minimize adverse visual and aesthetic impacts to surrounding land uses and structures. ■ Screening standards: PWSF's shall be screened or camouflaged through employing the best available technology and design, as determined by the city. Equipment Enclosure • Document why higher priority locations are not being proposed. o Equipment enclosures shall be placed underground. o Equipment enclosures shall be placed in an existing, completely enclosed building. o Equipment enclosures shall be placed above ground in an enclosed cabinet that shall not exceed six feet in height and occupy more than 48 square feet of floor area, including areas for maintenance or future expansion. File #07-101627-00-PC Doc ID 40563 Mr. Smith Page 3 . May 2, 2007 Above ground equipment enclosures shall be screened with one or a combination of fencing, walls, landscaping, structures, building or topography which will block the view of the equipment enclosure. Additional Standards for Equipment Enclosures in ROWs • Equipment enclosures shall be designed, located, and screened to minimize adverse visual impacts from the public right-of-way and adjacent properties. • Fencing around equipment enclosures shall not exceed six feet in height. PUBLIC WORKS DEVELOPMENT SERVICES DIVISION (Ann Dower, 253-835-2732, ann.dower@cityoffederalway.com) A franchise agreement and right-of-way permit is required for any work within the public right-of-way. Please contact Kathleen Messinger at 253-835-2725 for more information. Structures of this size are not permitted within the public right-of-way. Smaller structures may be approved on a case -by -case basis. Facilities should be placed underground whenever possible. CLOSING This letter reflects the information provided at the preapplication meeting and is intended to assist you in preparing plans and materials for formal application. We hope you found the comments useful to your project. We have made every effort to identify major issues to eliminate surprises during the City's review of the formal application. The completion of the preapplication process in the content of this letter does not vest any future project application. Comments in this letter are only valid for one year as per FWCC Section 22-1657. As you know, this is a preliminary review only and does not take the place of the full review that will follow submission of a formal application. Comments provided in this letter are based on preapplication materials submitted. Modifications and revisions to the project as presented for this preapplication may influence and modify information regarding development requirements outlined above. In addition to this preapplication letter, please examine the complete FWCC and other relevant codes carefully. Requirements that are found in the codes that are not addressed in this letter are still required for your project. If you have questions about an individual comment, please contact the appropriate department representative noted above. Any general questions can be directed towards the key project contact, Laura Kim, 253-835-2641. We look forward to working with you. Sincerely, aura Kim Associate Planner enc: Use Process III Handout Land Use Application c: Ann Dower, Public Works File #07-101627-00-PC Doc ID 40563 CITY OF FEDERAL WAY COMMUNITY DEVELOPMENT REVIEW COMMITTEE Pre -application Conference Sign In Sheet Project Name: 6 prifel Address: ILI D T (- File #: 0 5 63 -U Date: YlI IO 9-001' NAME 1. A Hm 2. 4,__Jnv3.0 v_ __D_ wvl� 3. REPRESENTING GD/Plann TELEPHONE NUMBER Z5 - e35 -1b4 7 17.Z7- SS -7 2s 3 r -�s - 2732- 4. t 1 IL 1/3 5. 0 .11 0 10. 11. 12. -------- 1 ---A _ (El SIDEWA.I1 21ST AVENUE SW [E] SIDEWALK C-n I3j ETnF�7 Q� �q'e7 w� - u nOAUiV �){ C� 1 7�� a 0m-' �� 0 mT tv : o p 6❑ b x q £ o - �00090= d 9 m b 4 4 h o F Y gX =sg�§ FAA€gm`g=� =gym m Im rri Rif x, i! � Y Sprint' z P A,All g 8 I_ 3-�>w4ppp€ y r Together with Ncxte[. m Y m 1 10545 WfttWS 1 � r 0100 kin tl T per, WA pW SQp a g J*tNC: (425) 276-7-15 o U Li u L FAX! (425] VO-7404 \A/ [E] SIDEWALK V . to 0 OB 0 0 00 0 0000 Q �rAll N F8A gg R u� F o So D ; n m S t7 R ? a m b.2 OZ m o Ae Dr 71 4 �� b � m x� a� >z n Sprint° Together with Nextel. ' y 147a5 WI'LDWS ROAD NE 0100 N s T RLDUOR0 WA 49052Z7B-7415 Z aL-J PHONE: {4]5) FM- 02]} 278-7404 I x!2 Sprint z a N `a y& y Together with Nextel. 8 c gu 9 b n�� WIDOWS BOAR NE 0100 bil m r REDMOND,pY26052 78- u r PHONE: (i16) 5] 278-7415 PlU FAX: (4I5) 270-7404 11 07 '! 22NE fl0.:e 3 i .ry �s -i4-Q3 i � -EN. ESMT. 25 _ NO 2 } S4 ---------------- — r�a.�r'{p:7f N 89-00-48 35 - 40-- —;a f; 3T 62ji °° o x CA a i ley ry � 39,62 71 LN Qo-s9 a3 E -Y� o o", �"cS✓, 29 N 64-SS 0 29 9?.. " +4 6D-59- S E i 1a5 4 �l FILE CITY OF CITY HALL �. 33325 8th Avenue South Mailing Address: PO Box 9718Fedara1Way Federal Way, WA 98063-9718 (253) 835-7000 www.cityoffederalway.com April 2, 2007 Shane Smith Sprint/Nextel 2465 8`h Avenue North Seattle, WA 98109 RE: File #07-101627-00-PC; SPRINT/NEXTEL CABINET @ 21" Avenue SW & SW 325`h Place Dear. Mr. Smith: The above -referenced proposal has been assigned to me as project planner. At this time, the application has been routed to the members of the Development Review Committee. A meeting with the project applicant and Development Review Committee has been scheduled as follows: 10:00 AM, Thursday, April 26, 2007 Hylebos Conference Room City Hall, 2"d Floor 33325 Bch Avenue South Federal Way, WA 98003 We look forward to meeting with you. Let me know if you will have more than five people attending the preapplication meeting so we can make arrangements for a larger room. This is the only notice sent out, so please coordinate directly with anyone else you would like to attend the meeting. Please call me at 253-835-2641 or email me at laura.kim@cityoffederalway.com if you have any questions. Sincerely, *V41 Laura Kim Associate Planner Doc. I.D. 40357 A�k RECEIVEID CITY OF MAR 2 9 �goF Federal WayITY OF FEDERAL WAY BUILDING DEn, MASTER LAND USE APPLICATION APPLICATION NO(S) 0 f 0 1 (a (�, 1 IT S DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8`h Avenue South PO Box 9718 " Federal Way WA 98063-9718 253-835-2607;Fax 253-835-2609 - www.cii offederalwa .com Date- (i - v -7 , q 5} SLJ Project Name 7 ^ : • �- 1 a Z� s Property Address/Location Parcel Number(s) ! a Project Description—Q» A' tda PI NAW PRINT Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Director--s Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information K W Zoning Designation b W Comprehensive Plan Designation (, U, OW Value of Existing Improvements �pC7F(?=Value of Proposed Improvements II]ternatimial Building Code (IBC): Occupancy Type Construction Type Applicant Name: Srv`%Ak-'�ie � Adds: 2, ill�� s3�" Are ! City/State: ,e.W, iw A 1610 Zip: Phone:C7(��'t-'I-� `71,• Fax: 12-6/ Z.V-7y+a`�, -�- Emat•1:�w►aeej Signature i J Agent (if different than Applicant) Name: yy�' Address: City/State: Zip: Phone: Fax: Email: Signature: Owner Name: Se, Address: City/State: Zip: Phone: Fax: Email: Signature: Bulletin #003 - August 18, 2004 Page 1 of 1 k:\Handouts\Master Land Use Application