Loading...
12-105017CITY OF Federal November 20, 2012 CITY HALL' y �. � i 33325 8th Avenue South Feder y Federal Way, WA 98003-6325 (253) 835-7000 www.cityoffederalway.com Tom Spaulding 1910 2nd Street Kirkland, WA 98033 RE: File #12-105017-00-UP; `PROCESS I `MxCTOR's APPROVAL' Sprint SE63X1311- Guinness, Right -of -Way at 32535 21" Avenue SW, Federal Way Dear Mr. Spaulding: The City of Federal Way's Community and Economic Development Department has completed an administrative land use review of the proposed upgrades to an existing Personal Wireless Service Facility (PWSF) on a 100-foot Puget Sound Energy (PSE) monopole located within the right-of-way adjacent to 32535 21" Avenue SW. Additional modifications to existing ancillary equipment located within a fenced area are also proposed. The modification is part of a technology upgrade being performed on Sprint Spectrum's network, in order to improve service to its customers in the area. The Process I application was submitted and determined to be complete on November 2, 2012. Your proposal is found to be consistent with provisions of Federal Way Revised Code (FWRC) Chapter 19.55, `Process I — Director's Approval', and Chapter 19.255, `Personal Wireless Service Facilities'. Your Process I proposal is hereby conditionally approved. The Process I land use approval is supported by the following statements of fact: 1. Zoning & Land Use —The zoning designation for the subject property is Single Family Residential (RS5.0). PWSFs are permitted in the RS zone pursuant to the zoning chart found in FWRC 19.220.120. 2. Review Process — According to submitted materials, the applicant proposes to remove/replace three existing antennas with three new antennas and add three Remote Radio Units. No height increase is proposed. One equipment cabinet will be removed and replaced with two new cabinets and ancillary equipment within an existing fenced equipment area. The replacement of antennas on an existing PWSF is subject to Process I Director's Approval pursuant to FWRC 19.15.030 `Review processes for improvements and additions to developed sites'. 3. Prioritized Locations — Applicant proposes PWSF improvements in "existing broadcast, relay, and transmission towers" or the second prioritized location set forth in FWRC 19.255.010(4). The highest prioritized location is not feasible as this proposal is an upgrade to an existing facility. Staff finds the applicant has met the burden to utilize the second prioritized location. 4. Cumulative Effects — The City must consider the cumulative visual effects of PWSFs mounted on existing structures and/or located on a given permitted site in determining whether additional permits may be granted so as to not adversely affect the visual character of the City. As shown on the site C.... . Spaulding, November 20, 2012 Page 2 plan, elevations, and photos, the replacement of three antennas with three new antennas and cabinet equipment are not a substantial increase to the existing site. The PWSF will not adversely affect the visual character of the City and there is no proposed height increase. 5. Facility — The existing and proposed facility exceeds microcell and minor facility thresholds defined in FWRC 19.05.130. Facilities exceeding such thresholds may be permitted if: (1) adverse visual impacts are not created; (2) equipment cabinets meet adopted development standards; and (3) the number of antennas and their size are appropriate for the location. All three criteria have been met as further analyzed in this document's findings. 6. Exempt Activity — Applicant proposes tb remove one cabinet and add two cabinets within the equipment enclosure. Proposed upgrades will occur within the enclosure and within the existing fenced area resulting in no exterior alteration. Therefore, these changes are exempt from PWSF standards set forth in FWRC Chapter 19.255 and are permitted outright with no further zoning compliance required pursuant to FWRC 19.255.010(3)(g). 7. State Environmental Policy Act (SEPA) — The proposed improvements are exempt from State Environmental Policy Act (SEPA) review per WAC197-11-800(3), as it is a minor repair/maintenance activity of an existing facility, no additional antennas are to be added. 8. Process I Thresholds —The proposed improvements meet Process I purpose criteria set forth in FVv1RC 19.55.020 including compliance with applicable provisions of FWRC Title 19 `Zoning and Development' and health, safety, and welfare standards. CONDITIONS OF APPROVAL The following conditions of approval are a component of this land use decision: 1. Prior to any site work, the applicant shall obtain a right-of-way permit from the city's Public Works Department. Please contact Kathy Messinger, Engineering Technician, at 253-835-2725 if you have any questions regarding the right-of-way permit. 2. Prior to any site work, the applicant shall obtain an electrical permit from the city's Department of Community and Economic Development. For further information regarding electrical permits, please contact the department's permit center at 253-835-2607. CLOSING This decision shall not waive compliance with future City of Federal Way codes, policies, and standards relating to this site. This Process I approval does not constitute approval of an electrical permit. The effective date of this decision is November 23, 2012, or three days from the date of this letter. Pursuant to FWRC 19.55.050, any person who received notice of this administrative decision may appeal the decision to the Federal Way Hearing Examiner by December 7, 2012. Any appeal must be in the form of a letter delivered to the Department of Community and Economic Development with the established fee. The appeal letter must contain a clear reference to the matter being appealed and a statement of the alleged errors in the Director's decision. No work on the proposal can commence until the end of the appeal period. 12-105017 Doc. I.D 62604 Mr. Spaulding November 20, 2012 Page 3 In that you are the only party of record, you may waive your right to appeal by submitting a letter to this effect to the City of Federal Way, Department of Community and Economic Development Services. Work on the site may not commence until you have been issued the appropriate electrical permit. This Process I approval is valid for one year from the effective date of this decision. If no further action is taken within one year, this decision will expire. A one-time, 180-day extension may be granted only if a written request is submitted to the City's Department of Community and Economic Development at least 30 days prior to the expiration of the decision. If you have any questions regarding this decision, please contact Becky Chapin, Assistant Planner, at 253- 835-2641 or rebecca.chapin@cityoffederalway.com. Sincerely, Isaac Conlen Planning Division Manager for Patrick Doherty, Director enc: Approved Site Plan c: Kathy Messinger, Engineering Technician Becky Chapin, Assistant Planner 12-105017 Doc. I.D. 62604 11/02/12 City of Federal Way Department of Development Services 33325 8t' Ave South Federal Way, WA 98003-6325 RECEIVED NOV 0 2 2012 CITY OF FEDERAL WAY CDS RE: Sprint Spectrum Network Vision in public ROW at 32535 215` Ave SW, Federal Way, WA City of Federal Way Staff Thank you for your review of the proposed Sprint Spectrum modification of an existing PWSF located in the public right of way adjacent to 32535 215t Ave SW. Sprint is in the process of modernizing their network in the City of Federal Way and are proposing the following modifications: The removal and replacement of the (3) three existing antennas on the existing PSE utility pole and the addition of (3) three Remote Radio Units. Within the existing equipment shelter Sprint is proposing to remove (1) one equipment cabinet and replace with (2) new equipment cabinets. No increase in height or increase in the equipment footprint is being requested. The antennas will be flush mounted to the existing pole and painted to match the utility pole. Please contact me with any questions you may have Tom Spaulding 1910 2"d Street Kirkland, WA 98033 Tom.spaufdingE iexcomcorta.com 650.380.3140 North Existing South Existing East Existing West Existing RECEIVE® NOV 0 2 2012 CITY OF FEDERAL WAY CDS e6 415dU 04 1�rr 1 JC �!LUIJ��1 J�VJ r cign --"r. o 10 (1Ff3CJ�i-1:i� t-GOAL Lli G i-,-1 �' o Q1v'o 1 'M \- It . - MOi-oLI *t'O:O G N¢ 40 d 8 D C J e• z-'r,tlr y u I cc a WWI T d M= N' N M z- Mir N LJ F M ti QG E O �+ .� N �^ i [M 11 N _•, �y +76!-Jkw. Poo' 0 O� rl� ifl `Y 'h J r �- 1 F U1(i I —le 17au4;,OW .01 %o QI OR !fig t e"Ict o t? , D vki-o 6 01, t wt-L) "j)a8�D3Ei �1e QI ti 0606`ki 0 U ,p N C! +E !i tf! [ r �N LM J `. M In Iz M r NNp� N' l�M M. Gt .. .. 7t'ry�lf%'/ki..J ljltl 11 li �`.,�1�)I',n RECEIVED NOV 0 2 2012 CITY OF FEDERAL WAY CDS i Proposed Sprint Spectrum Network Vision Modification Proposed Sprint Modification ��H w dal Ik[� M �w.c •• water w�YM.�[e.•� qI unw. a i Existing Sprint Facility NOV 02 2012 CITY OF FEDERAL, WAY CDS RECEIVED MASTER LAND USE APPLICATION DEPARTMENT OF COMMUNITY DEVELOPMENT SERVICES 33325 8`h Avenue South CITY OF _ =`f NOV 0 2r 20�2 Federal Way, WA 98003-6325 09 Federal Waya-ry 253-835-26.ci Fax www.ciMffederalway.com OF FEDERAL WAY www.ci offecieratway.cam CDS APPLICATION NO(S) I r Date- M - I 1 Z- project Name „f>�,r:t0- Nzt'"'ar� Property Address/Location \° „k-- 3�5 5 3 2 I s+ Jr- 5 �,3 Parcel Number(s) 1v Si i S oc N �� `� k G \ o `{' '5 3 T? CT Project Description a� Del PLEASE PRINT Type of Permit Required Annexation Binding Site Plan Boundary Line Adjustment Comp Plan/Rezone Land Surface Modification Lot Line Elimination Preapplication Conference Process I (Director's Approval) Process II (Site Plan Review) Process III (Project Approval) Process IV (Hearing Examiner's Decision) Process V (Quasi -Judicial Rezone) Process VI SEPA w/Project SEPA Only Shoreline: Variance/Conditional Use Short Subdivision Subdivision Variance: Commercial/Residential Required Information S — LS5 Zoning Designation Comprehensive Plan Designation 5c),ota Value of Existing Improvements _% j coca. � _ Value of Proposed Improvements International Building Code (IBC): Occupancy Type V 3 Construction Type c,&L � �Q�3'S -�' PSE 7zit FFCity/State: icant : ss: C, z u a o,, ar` S Y lrt� 2�' i Zip: lo(o ZS 1 Phone: Fax: Email: Signature: Agent (if different than 1Aipplicant) Name: �bM �pn„`a:n0 Address: c- S* City/State: IC,-,- t\ Q.-.L\ �A k Zip: 9 0 a 3 Phone: C05z . -5 3 (,-k C." Fax: Email: Tr, In.S(7Slik.^ �12„c�o...C6cP.(�M 4 Signature: Owner Name: Address: City/State: / Zip: Phone: Fax: Email: Signature: Bulletin #003 — January 1, 2011 Page 1 of 1 k:\Handouts\Master Land Use Application Call Before you Dig 1-800-424-5555 Northwest Utility Notification Center www.washington8il.com WASHINGTON STATE CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT WORK NOT CONFORMING TO THESE CODES. • 2009 IBC, STANDARDS AND AMENDMENTS—WAC 51-50; • 2009 IMC, STANDARDS AND AMENDMENTS—WAC 51-52; • 2009 IFC, STANDARDS AND AMENDMENTS—WAC 51-54; • 2009 IPC, STANDARDS AND AMENDMENTS—WAC 51-56; 51-57 ACCESSIBILITY REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS REQUIREMENTS ARE NOT REQUIRED IN ACCORDANCE WITH THE 2009 IBC BUILDING CODE. CODE BLOCK _ SPRINT PROPOSES TO MODIFY AN EXISTING UNMANNED TELECOMMUNICATIONS FACILITY --TEMP TO PERM • REMOVE (3) EXISTING PANEL ANTENNAS (1 PER SECTOR) • INSTALL (3) NEW PANEL ANTENNAS (1 PER SECTOR) • REMOVE (1) MODCELL (OUTDOOR EQUIPMENT • REMOVE (1) BBU OUTDOOR CABINET • INSTALL (1) NEW OUTDOOR MMBS CABINET • INSTALL (1) NEW OUTDOOR BBU CABINET • REMOVE ALL EXISTING SPRINT ANTENNA COAXIAL CABLES • INSTALL (3) NEW HYBRID CABLES USING EXISTING COAX ROUTE (1 PER SECTOR) • INSTALL (3) NEW RRU'S PROJECT DESCRIPTION APPROVAL SIGNATURE DATE SITE ACQUISITION MANAGER CONSTRUCTION MANAGER A&E MANAGER PLANNING CONSULTANT RF MANAGER RF ENGINEER PROPERTY OWNER SPRINT REPRESENTATIVE AAV MANAGER SIGNATU E .BLOC ■ THIS IS AN EXISTING SPRINT WIRELESS TELECOMMUNICATION FACILITY NETWORK VISION EQUIPMENT UPGRADE EIR&Tkyw-lim '� � � I! � � � 1� 1uzwo GUINNEASS 32535 21 ST AVE SW FEDERAL WAY. WA 9 032 INC COUNTY LATITUDE, 47.310317 47® 189 37.1799 N (NAD 3) (CPS READING) LONGITUDE: -1 22.36076 / 1 22' 2109 38.74 99 W (NAD 83) (GPS READING) TRANSMISSION POLE Si 1 u SITEP �* F.3 �3 G, h- t SY1 33Tt�f�3t_ . :. a .. s t St a� x b; t� Imo, \�'■I�_��� SW 320th St W 322nd St o 325ths v SITE s3zs'o P I z svi 326th St T VICINITY MAP FROM GENERAL DYNAMICS (BELLEVUE, WA) OFFICE: TAKE 1-405 SOUTH TOWARD RENTON. TAKE 1-5 RAMP SOUTH TOWARD PORTLAND, EXIT 143 TAKE RAMP RIGHT ONTO S 320TH ST, TURN LEFT OFF OF SW320TH ST ONTO 21 ST AVE SW. SITE IS ON NE CORNER OF 21 ST AVE SW AND SW 25TH PLACE. SEATTLE N"R-KET SHEET DESCRIPTION TITLE SHEET GENERAL NOTES T-1 N-1 N-2 GENERAL NOTES A-1 OVERALL SITE PLAN A-2 ENLARGED SITE PLAN A-3 ENLARGED EQUIPMENT PLANS A-4 ANTENNA PLANS AND SCHEDULES A-5 NEW NORTH & WEST ELEVATIONS A-6 EQUIPMENT DETAILS A-7 EQUIPMENT DETAILS (OUTDOOR SPECIFICATIONS) A-8 EQUIPMENT DETAILS A-9 EQUIPMEIT DETAILS RF-1 ANTENNA AND CABLE COLOR CODING DETAILS E-1 ONE -LINE DIAGRAM & POWER PANEL SCHEDULE E-2 DC POWER ONE —LINE DIAGRAM E-3 ELECTRICAL DETAILS (OUTDOOR SPECIFICATIONS) E-4 CONDUIT ROUTING E-5 GROUNDING PLAN E-6 GROUNDING DETAILS E-7 GROUNDING DETAILS SHEET IN EX APPLICANT: SPRINT SPECTRUM LLC 6200 OVERLAND PARK WAY KANSAS CITY, MO 66251 PROPERTY INFORMATION: SITE ADDRESS: 32535 21ST AVE SW FEDERAL WAY 98023 PROPERTY OWNER: CITY OF FEDERAL WAY 33530 1ST WAY S., PO BOX 9718 FEDERAL WAY, WA 98063 TOWER OWNER: PUGET SOUND ENERGY (PSE) COMMUNICATION SITINGS & SERVICES PO BOX 97034—EST06E BELLEVUE, WA 98009 CONTACT: TIM GASSER PH: (425) 456-2773 EMAIL: tim.gasser@pse.com TOWER ID: 31 1695-162137 ZONING CLASSIFICATION: SR-6 CONSTRUCTION TYPE: VB OCCUPANCY: U JURISDICTION: CITY OF FEDERAL WAY CURRENT USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY NEW USE: UNMANNED WIRELESS TELECOMMUNICATIONS FACILITY PARCEL NUMBER( LEASE AREA: ROW ADJ. TO 010453TRCT 300± SF — NO ADDITIONAL LEASE SPACE REQUIRED PROJECT SUMMARY ARCHITECT: PB TELECOM, INC 303 BATTERY ST SEATTLE, WA 98121 CONTACT: SHAWN VAN GIESEN PH: (206) 838-9275 EMAIL: shawn.vangiesen@pbtelecom.net STRUCTURAL ENGINEER: ADAPT ENGINEERING 615 8TH AVE S SEATTLE, WA 98104 CONTACT: KV LEW PH: (206) 227-7255 EMAIL: kvlew@adaptengr.com SITE ACQ./LEASING: LEXCOM DEVELOPMENT 615 8TH AVE S SEATTLE, WA 98104 CONTACT: TOM JOHNSON PH: (206) 351-0893 EMAIL: tom.johnson@lexcomcorp.com ZONING/PERMITTING: LEXCOM DEVELOPMENT 615 8TH AVE S SEATTLE, WA 98104 CONTACT: TOM SPAULDING PH: (650) 380-3140 EMAIL: tom. spaulding@lexcomcorp.com CONSTRUCTION MANAGER: GENERAL DYNAMICS WIRELESS SERVICES 1000 124TH AVE NE, SUITE 200 BELLEVUE, WA 98005 CONTACT: ED MARQUEZ, SR CONSTRUCTION MANAGER PH: (425) 736-4991 EMAIL: edward.marquez1@gdit.com PROJECT MANAGER: GENERAL DYNAMICS WIRELESS SERVICES 1000 124TH AVE NE, SUITE 200. BELLEVUE, WA 98005 CONTACT: DAVID SIMARD PH: (425) 201-3747 EMAIL: david.simard@gdit.com BUILDING DEPARTMENT: CITY OF FEDERAL WAY 33325 8TH AVE S FEDERAL WAY, WA 98003 CONTACT: — PH: (253) 835-2607 EMAIL: — AAV MANAGER: GENERAL DYNAMICS WIRELESS SERVICES 1000 124TH AVE NE, SUITE 200 BELLEVUE, WA 98005 CONTACT: STEVE LEUPOLD PH: (425) 623-5782 EMAIL: steven.leupoid@gdit.com RE ENGINEER: STA NETWORK SERVICES 1000 124TH AVE NE, SUITE 200 BELLEVUE, WA 98005 CONTACT: MIKE LEE PH: (425) 201-3751 EMAIL: mike2.lee@sta.samsung.com PROJECT TEAM Sprint!)o --- �_l P-p-p-pp"p-p- A PSAMSUNG 'A GENERAL DYNAMICS WIRELESS SERVICES PB TELECOM 303 BATTERY STREET SEATTLE, WA 98121 �j ph 206.838.9275 Q 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SEC3XC311 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8 - 21 12 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE . DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA f NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: ST F T), �'v __01PROVAL Perh_:: mitNt_ ;r:_Ll.5dr'?-V-P Approve&By: Date: :..�.. RECEIVED NOV 0 2 2012 CM OF FEDERAL WAY CDS SHEET TITLE: TITLE SHEET SHEET NUMBER: REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CONSIKUGIIUN UUUUML.NIS 15 F'KUFKItIAKY by NAIUKt. AINY UJt UN UIJI.LUJUML UIP1r_N (MAIN Ir-tAl tlVtlIUM KLLAILD IV I,HRrRICrC Z>r_MVII..CJ IJ JIRIUILT rMUr7InJILU. S p r i n -, rir 'o ----7 S A IM S jUN AG GENERAL® DYNAMICS WIRELESS SERVICES U PB TELECOM 303 BATTERY STREET l SEATTLE, WA 98121 i ah 206.838.9275 tQ 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE- 0 8 21 -1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: OVERALL SITE PLAN SHEET NUMBER: 1 REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CONSIRUCIIUN UUUUMtIVI� 15 I-NUI-'KILIANT UT IVHIVtCC. HIV[ UIDL- -111. 11-1-- - -- --- - - - - - EXISTING CURB EXISTING OVERHEAD UTILITIES EDGE OF SIDEWALK I I a I � C EXISTING SPRINT - IANTENNAS LOCATED ON 100'f PSE WOOD I DISTRIBUTION POLE I I f I I m I ' I m I Iw z Uj w ri O II� � z A 5 I cn I x m EXISTING SPRINT WOOD FENCE w REPLACE AND REPAIR AS NEEDED WITH SIMILAR MATERIALS I I I m I f I m I I I m I I EXISTING SPRINT OUTDOOR EQUIPMENT ON CONIC PAD m ' I I EXISTING ' SPRINT EXISTING SPRINT MODCELL UNDERGROUND COAX IN ' CABINET 4"0 CONDUIT EXISTING SPRINT GPS m (1' 0V t, ERIFY ROUTE) ANTENNA LOCATED ON ' C EXISTING UTILITY FRAME �,O � E T ' I OE[m O I i ' EX. CONDUIT ON STANDOFFS, TYP m EXISTING EX. ICE BRIDGE -� EQUIPMENT EXISTING SPRINT CABINET UTILITY H-FRAME mEl IEl' r m / I I ' -' EXISTING ACCESS GATE I ( I I w Z m J FF- w 0- 0 af OL m ( O Z I ~ I � I x w m I I I m Call Before you Dig 1-800-424-5555 Northwest Utility Notification Center www.washington811.com 22"x34" SCALE: 1 /2" = 1 '-0" ENLARGED SITE PLAN 11"x17" SCALE: 1/4" = 1'-0" 2' 1' 0" 2' ri In-r un nnl I nrl n-rTOI!`TLIItJ ITCiI Spnnt!)o FSPA"IM S U N G 07 6bm,__ j!d A GENERAL DYNAMICS WIRELESS SERVICES PB TELECOM 303 BATTERY STREET SEATTLE, WA 98121 (pD 206.838.9275 %G 0 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH T-%, T ESS GUIN 'x 1 SE63XC311 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8— 2 1— 1 2 ISSUED FOR.: PREL 100% CD SUBMITTAL_ REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21/12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSUR E: SHEET TITLE: ENLARGED SITE PLAIN SHEET NUMBER: A�2 REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CUNSIKUCIIUIV UUUUMtNIJ 15 FNUr-NltiHr�T nT N/Alumr- /1141 VJF- Vr\ VIJVLVJVI\L VIIILI 11, - - .— - 11'-1.of0"± op 2"± 3"± 2'-0"± 3'-0"± 2"± 4-0 EXISTING UNDERGROUND POWER TELCO CONDUITS -H 41 -H (VERIFY ROUTE) 00 +I / II EXISTING SPRINT EXISTING SPRINT I GPS ANTENNA N EQUIPMENT PAD " N II —H _ _ _ _ _ NEW SPRINT OUTDOOR GPS EXISTING I I ON NEW MMBS CABINET +I EXISTING EXISTING BBU EXISTING 3 4 o T SPRINT ( I I MODCELL SPRINT TO I r Mitt i I BE A-8 A-8 N BBU MODCELL �" REMOVED)' I (TO BE I WOOD FENCE - - - I REMOVED) REPAIR AS f, I REQUIRED WITH o co L _ _ _ _ _ it co SIMILAR MATERIAL � k C 7C��'�- NEW SPRINT OUTDOOR �q�. E T MMBS CABINET ON TEMP PRECAST CONC PAD EXISTING SPRINT 0E[ EQUIPMENT PAD O E[ EXISTING SPRINT UTILITY H-FRAME 4 7 A-7 A-9 EXISTING SPRINT UNDERGROUND COAX ROUTE (VERIFY ROUTE) EX. 4" CONDUIT EXISTING SPRINT GPS ANTENNA ON STANDOFFS (TO BE REMOVED) EXISTING SPRINT EXISTING UNDERGROUND COAX ROUTE EXISTING EX. 4" ICE BRIDGE TO EQUIPMENT EQUIPMENT REMAIN (VERIFY ROUTE) CONDUIT ONEXISTING TO REMAIN (TO REMAIN) STANDOFFS UTILITY H SPRINT FRAME El 16.5° ICE BRIDGE (TO REMAIN) NEW SPRINT UNDERGROUND 16.5° -a-� HYBRID CABLE ROUTE TO EXISTING 4" CONDUITS TRUE MAGNETIC TRUE MAGNETIC NORTH NORTH NORTH 2 NORTH- F EXISTING SPRINT WOOD FENCE ACCESS GATE REPAIR AS REQUIRED WITH SIMILAR MATERIAL I N'' l�l 22"x34" SCALE: 3/8" = 1 '-O" NEW TEMP. . EQUIPMENT PLAN (INTERIM) 2 22"x34 11"x17" SCALE: 3/16" 1'-0" 2' 1 SCALE: 3/8" = 1'—o EXISTING EQUIPMENT PLAN 1 0" 2' �- 11"x17" SCALE: 3/16" = 1'-0" 2' 1' 0" 2' = ' NOTES: o' 2'-4"± 2'-4"± 6"± 1. EXISTING EQUIPMENT LAYOUT BASED ON DRAWINGS BY KDC ARCHITECTS -ENGINEERS, DATED 05/21 /12. 5„± f{ --H i NEW SPRINT OUTDOOR GPS ON NEW MMBS CABINET -H / 3 4 j' +I EXISTING ITEMS TO BE REMOVED CDMA ANTENNA (3 TOTAL, 1 PER SECTOR) CDMA CABINET 1 BBU CABINET 1 MICROWAVE CABINET N/A COAX CABLE (6 TOTAL, 4 PER SECTOR) sprin IPSPA M S U N G GENERAL DYNAMICS WIRELESS SERVICES \ PB TELECOM \ 303 BATTERY STREET SEATTLE, WA 98121 j Ph 206.838.9275 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH T ESS G Uy I NIN C1 32535 21 ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8— 2 1— 1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: ENLARGED EQUIPMENT PLANS SHEET NUMBER: A- 0 3 REVISION: B 120049 1 6 NEW SPRINT 1900 MHZ A I D j/ j �/ j QUAD ANTENNA _ Q 0 IN �/ ryI= Flo L/� co40 O I EXISTING RELOCATED SPRINT CDMA , �I�' �~�- U I ANTENNA AND MOUNTING PIPE WIN (TO BE REMOVED) { / NEW SPRINT 1900 MHZ RRU cf)I Q (TYP OF 3) EXISTING SPRINT CDMA ANTENNA j { 4 NEW SPRINT ANTENNA STANDOFF 5 6 6 (TO BE RELOCATED, TEMPORARY); -9 (TEMPORARY, TO BE REMOVED) A-6 A-6 A-8 REUSE EXISTING MOUNTING PIPE EXISTING SPRINT CONDUITS x EXISTING SPRINT CONDUITS r' EXISTING SPRINT ANTENNA MOUNT NEW SPRINT ANTENNA MOUNT (TO BE REMOVED) EXISTING PSE CONDUITS 18" 0 EXISTING SPRINT CDMA ANTENNA EXISTING PSE CONDUITS EXISTING RELOCATED SPRINT CDMA (TO BE RELOCATED, TEMPORARY); ANTENNA AND MOUNTING PIPE REUSE EXISTING MOUNTING PIPE (TO BE REMOVED) \ 0 2 6 NEW SPRINT 1900 MHZ J QUAD ANTENNA )5 E lb 3d r y r7 J sF / ACT EXISTING 100'± PSE WOOD TRANSMISSION POLE \� EXISTING �7�/ TRANSMISSION `�0\� WOOD ,,G / POLE ��) sC'16 16.5° ° I'% \ � TO �I��y� \ .5 � EXISTING SPRINT CDMA ANTENNA ��G (TO BE RELOCATED, TEMPORARY); TRUE MAGNETIC / Q� NEW SPRINT ANTENNA STANDOFF /y TRUE MAGNETIC REUSE EXISTING MOUNTING PIPE NORTH NORTH �/ (TEMPORARY, TO BE REMOVED J� NORTH NORTH NOTE EXISTING RELOCATED SPRINT CDMA REMOVE EXISTING WOOD POLE ANTENNA AND MOUNTING PIPE 3 SECTOR MOUNT AND (TO BE REMOVED) REPLACE WITH NEW MOUNT. RELOCATE EXISTING ANTENNA N MOUNT PIPES TO NEW SIDE MOUNT ARM PER PLAN. 22"x34" SCALE: 1" EXISTING ANTENNA PLAN 1 2211"xl7" SCALE: 1/2" 1 10-0" 6.. 0"NEW TEMP. ANTENNA PLAN (INTERIM) 2 1 1 "x 1 7" SCALE: 1 /2" = 1 ' -0" 1 ' 6" 0" J� NOTES: 1. ANTENNA MOUNT DRAWINGS & CALCULATIONS BY ANTENNA MOUNT MFR. / 1 6 NEW SPRINT 1900 MHZ O /� 2. EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE. A-8 A-8 QUAD ANTENNA ` / Q 3. NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRU'S WHICH SHALL BE MOUNTED TO THAT SHOWN ON DETAIL 6, SHEET A-8. to 4. FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS. NEW SPRINT 1900 MHZ RRU 5. ALL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAID CENTER AND ORIENTATIONS WITH SPRINT (TYP OF 3) PCS PRIOR TO INSTALLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. CONTRACTOR SHALL REFER TO 5 6 6 TOWER STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. A-6 A-6 A-8 6. PAINT NEW ANTENNAS AND ASSOCIATED HARDWARE TO MATCH THE PAINTED CONDITIONS OF THE EXISTING ANTENNAS, OR AS REQUIRED BY JURISDICTION. NEW SPRINT ANTENNA MOUNT TYPICAL OF 3 EXISTING SPRINT CONDUITS 7. PAINT NEW CONDUIT TO MATCH EXISTING. EXISTING PSE CONDUITS 2 6 NEW SPRINT 1900 MHZ 0 A-8 A-8 QUAD ANTENNA O O 1900 EQUIPMENT (7200 -'CT" RRU / HYBRID CABLE SCHEDULE SECTOR RRU MODEL RRU FREQUENCY HYBRID CABLE LENGTH HYBRID CABLE DIAMETER JUMPER SIZE JUMPER LENGTH RET LENGTH RET CABLE MANUFACTURER RET CABLE MODEL NUMBER ALPHA RRH-P4 190OMHz 150'± 1.06" 1/2" 4' 9.8' COMMSCOPE iRET AISGv2.0 BETA RRH-P4 1900MHz 1 150'± 1.06" 1 /2" 4 9.8' COMMSCOPE iRET AISGv2.o GAMMA RRH-P4 190OMHz 150'± 1.06 1/2" 4' 9.8' COMMSCOPE iRET AISGv2.0 ANTENNA SCHEDULE SECTOR ANTENNA FREQUENCY ANTENNA MFR. ANTENNA MODEL ANTENNA QUANTITY AZIMUTH RAID CENTER ANT. SIZE ELECT TILT MECH TILT ALPHA 1900 MHz RFS APXVRR13-C-A20 1 (PER SECTOR) 15° 96'-0" 54.8" -3° 0° BETA 1900 MHz COMMSCOPE HBXX-9014DS-A2M 1 (PER SECTOR) 120° 96'-0" 50.9" -3° 0° GAMMA 1 1900 MHz t COMMSCOPE HBXX-9014DS-A2M 1 (PER SECTOR) 225° 96'-0" 50.9" -4° 0° EXISTING 100'± PSE WOOD TRANSMISSION POLE 16.5° (3 / § ��Go J TRUE MAGNETIC NORTH NORTH IG� NOTE; REMOVE EXISTING CDMAt..� ANTENNAS AND SIDE ARMS PER PLAN 22"x34" SCALE: 1" = 1'-0" NEW ANTENNA PLAN (FINAL) 13, NOTES & ANTENNA SCHEDULE 4 1 1 "x 17" SCALE: 1 /2" = 1 ' -0" 1' 6" 0" 1 ' THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sproint!)o rS A IMSU N G GENERAL DYNAMICS WIRELESS SERVICES PB TELECOM 303 BATTERY STREET SEATTLE, WA 98121 / . Ph 206.838.9275 ® 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21 ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8 - 21 -12 ISSUED FOR: PREL 100% CD SUBMITTAL_ REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: ANTENNA PANS 8c SCHEDULES SHEET NUMBER: A— REVISION: B 120049 OILT.O. EXISTING POLE 100'-0"± (PSE TO VERIFY) C.L. OF NEW SPRINT ANTENNAS 96'-0" C.L. OF EXISTING SPRINT UPPER ANTENNAS REMOVED 96'-0"± EX. NEW CAE NEW SF CAB I NEW SPRINT OU ON NEW MMfI t EXISTING SPRIT` WO( REPAIR AS WITH SIMILAR GRADE ASSUMED 0'-0" TER QUAD ANTENNA 3 -OR) A-4 RRU 3 OR) A-4 iom NOTE: MATCH NV TOP OF ANTENNA HEIGHTS WITH CDMAs T.O. EXISTING POLE 100'-0"± (PSE TO VERIFY) C.L. OF NEW SPRINT ANTENNAS 96'-0' C.L. OF EXISTING SPRINT UPPER ANTENNAS (REMOVED) ; 96'-0"± %1 GRADE ASSUMED 0'-0" NEW SPRINT HYBRID CABLE ROUTED IN EXISTING CONDUIT 6 2 A-8 RF-1 NOTE: STRUCTURAL ANALYSIS PROVIDED BY OTHERS FOR PRIMARY STRUCTURE. ANTENNA MOUNT DRAWINGS & CALCULATIONS BY ANTENNA MOUNT MFR. EXISTING OMNI ANTENNA EXISTING WHIP ANTENNAS EXISTING ANTENNA CANISTER NEW SPRINT 1900 MHZ QUAD ANTENNA 3 (TYP OF 3, 1 PER SECTOR) A-4 NEW SPRINT 1900 MHZ RRU 3 (TYP OF 3, 1 PER SECTOR) A-4 EXISTING 100'± PSE WOOD TRANSMISSION POLE EXISTING HIGH VOLTAGE INSULATOR, TYP EX. CONDUIT ON STANDOFFS, TYP t EXISTING CROSSARM—� !,,—EXISTING CROSSARM NEW SPRINT OUTDOOR GPS— ON NEW MMBS CABINET 3 4 A-8 A-8 NEW SPRINT OUTDOOR BBU CABINET ON EXISTING PAD 5 7 A-7 A-9 WOOD FENCE REPAIR AS REQUIRED WITH SIMILAR MATERIAL 22"x34" SCALE: 1 /8" = 1 '-0" Ilywi. 1NEW NORTH ELEVATION 22"x34" SCALE: "x17" 1 /8" = 1 '—O" NEW i v L VIM l �l WEST ELEVATION LE J A TIO T21 1 1 "x17" SCALE: 1 /16" = 1'—O" 8' 6' 4' 2' 0" 8' i 1 1 SCALE: 1 /1 6" _ —0" 8' 6 4' 2' 0" 8' Sprint!)P�> r'o — __­q7 SA IMSU N G 61b.__ __ ! A GENERAL DYNAMICS WIRELESS SERVICES PB TELECOM Q 303 BATTERY STREET SEATTLE, WA 98121 Ph 206.838.9275 Q 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNLSS C.1 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8 - 21 — 1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL ALA B 08/21/12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: NEW NORTH & WEST ELEVATIONS SHEET NUMBER: A-5 REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CONSIRUCIIUN UUUUMLNIJ 15 NKUHNILIANY by NAIUKt. ANT UJt UM UIJILUJUf-,C vines inr\iN inHi vvn11,n 1v av\iLi\ JLI\YIVLJ w JIIVVILI r �w iuiiLv. MOUNTING PIPE NEW 1900 MHZ RRU NEW SAMSUNG NEW HYBRID FREQUENCY //,NEW ANTENNA PIPE MOUNT CABLE HYBRID BREAK-OUT NEW SAMSUNG RRU CYLINDER AND ENCLOSURE. MOUNTING HARDWARE CONTRACTOR SHALL MOUNT WITH ADEQUATE HARDWARE TO NEW PIPE MOUNT EXISTING FRAME, HARDWARE. CONTRACTOR SHALL USE ADEQUATE HARDWARE THAT FITS WITH AN EXISTING FRAME. NEW HYBRID CABLE FROM NEW RF CABINET NEW PANEL ANTENNA WITH MOUNTING EXISTING ANTENNA HARDWARE FRAME NEW JUMPER (TYP. ) REFER TO 6/A-8 22"x34" SCALE: NOT TO SCALE ANTENNA &HYBRID CABLE 1 22"x34" SCALE: NOT TO SCALE NOT USED "x17" 2 22"x34" SCALE: NOT TO SCALE NOT USED "x1 3 22"x34" SCALE: NOT TO SCALE NOT USED "x17" 4 1 1 "x17" SCALE: NOT TO SCALE 1 1 SCALE: NOT TO SCALE 1 1 7" SCALE: NOT TO SCALE 1 1 SCALE: NOT TO SCALE 1 '-1 3/4" PER RRU — — OPTIC PORT ANTENNA PORTS — — — — — — - TECHNOLOGY REQUIREMENTS �r I I I I O NEW SAMSUNG MOUNTING 00 00 BRACKET AND " o o 0 0 o I HARDWARE NEW I . . El ED ( SAMSUNG 0 0 0 0 0 3 1/2" O.D. MOUNTING ANT 0 ANT 1 ANT 2 ANT 3 I o 0 00 MOUNTINGPIPE p BRACKET AND U e HARDWARE ow � z �� yw Lu I o I L cif cr 0 DIMENSIONS � w Li 'cr i �----- -------------- HxWxD: 350x6O5x228mm �0 a i�GROUND POWER RET (13.8"x23.8"x9) i PORT PORT WEIGHT: 65LBS w i -48 B i VOLTS MOUNTING TABS, TYP. i e FGND @O ( 0 0 3 1/2" O.D. 3 1/2" O.D. I MOUNTING PIPE MOUNTING PIPE IE O O 1 TOP VIEW LEFT SIDE VEW FRONT VIEW o 0 I o 0 o 22"x34" SCALE: NOT TO SCALE 1900 MHZ RRH-P4 MECHANICAL SPECIFICATIONS 5 22"x34" SCALE: NOT TO SCALE RRI_I POLE INSTALLATION DETAIL11%17" SCALE: NOT TO SCALE 11"xl7" SCALE: NOT TO SCALE 6 RECTIFIER RF—ANTENNA NI UADU 5) CPRI CABLE 6) RET CABLE 4) POWER CABLE O O O G O O O Y 0 1 2 3 ®� 7) RF CABLE 3) RRH-P4 GROUND CABLE FEEDER LINE GROUND CABLE � (GROUND KIT/7/8 IN. FEEDER ' LINE OR MORE) MGB TGB I rl) GROUND CABLE 2) TGB GROUND CABLE ® TGB AND GROUND KIT ARE USED IN CASE 1 ® OF THE 7/8 IN. FEEDER LINE OR MORE 22"x34" SCALE: NOT TO SCALE SAMSUNG MMBS WIRING DIAGRAM 7 22"x34" SCALE: NOT TO SCALE NOT USED g 1 1 "x17" SCALE: NOT TO SCALE 1 1 "x1 7" SCALE: NOT TO SCALE S p r i nsy rS A'OM7,S. U N G ENER.AL DYNAMICS WIRELESS SERVICES PB TELECOM �303 BATTERY STREET \l Q SEATTLE, WA 98121 ph 206.838.9275 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8— 2 1— 1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: A-6 REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIERVI IS STRICTLY PROHIBITED �v' 2'-4" 36" MAX 2'-4" w C) zo Q Q o' J � O N � to N ro NEW NEW `n I i BBU MMBS N CABINET CABINET v z Q I w I ITEM SPECIFICATIONS CAPACITY MAX. 4 BATTERY STRINGS AIR-CONDITIONER/COOLING COOLING WITH FAN FOR EMERGENCY MODE (MCLEAN T20 HVAC) SOUND LEVEL 65BA ®1.5m 71(H) x 41.25(D) x SIZE 27.6(W) INCH 1800(H) x 1048(D) x 700(W) mm CABINET WEIGHT 370 LBS PER BATTERY 529 LBS STRING WEIGHT NARADA 190AH BATTERY (12NDT190) AGM TYPE (VRLA) AC POWER 220VAC, 3.5AMP TYP. 14.4AMP STARTING DC POWER 1OA MAX @48DVC FRONT VIEW AC INPUT CIRCUIT BREAKER BATTERY BREAKER #4 4TH BATTERY BATTERY BREAKER #3 3RD BATTERY BATTERY BREAKER #2 BATTERY BREAKER #1 2ND BATTERY BATTERY CABLE TERMINAL d GROUND BAR i ,-� z CABLE ENTRANCE 1ST BATTERY p i0co � i � I _ — 22"x34" SCALE: NOT TO SCALE OUTDOOR. MMBS & BBU TYPICAL PICAL LAYOUT OI.,tT 1 22"x34" SCALE: NOT TO SCALE OUTDOOR. MMBS CABINET 2 3' —5" 2'-3" 3'-0» 2' —7„ N 0 0 0 �w o 2'-8„ 3'-4" TOP VIEW O I Lo Lo 0 0 0 O O O O 0 a 000 0 101 8 O 888 O O O 8 O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 8 8 8 0 0 0 0 0 0 0 0 0 0 8 0 0 0 8 0 0 8 0 8 o ° ° cm Ld cm 0 cm cn :D o " cy o CD w 0 o ry 8 0 0 0 o 0 0 g 0 g 0 NoM Mori ° au w o w 0 0 ° I ° � m MoN� MoM � O w 0 T 2'-3» HEX HEAD STOPPING PLUGS 2" 1'-10" 2" 2'-5" 2'-3" — 2" 2'-3" BACK VIEW SIDE VIEW FRONT VIEW 0 1 1 » TOP WITH 465.1 19" MOUNTING jli ° LIFTING LUGS 00 CAp I r: 0 0 0 �T 2'-1" 2'-2" I SECTION B BOTTOM VIEW TOP VIEW �- 2'-5„ BOTTOM MMBS EQUIPMENT WEIGHT & DIMENSIONS BBU EQUIPMENT WEIGHT & DIMENSIONS MMBS CABINET l800x7OOx1018(820)mm/70.8in x 29.5in x 40.1(37.0)in BBU CABINET l800x7OOx1018(820)mm/70.8in x 29.5in x 40.1(37.0)in MMBS CABINET 251kg (553lbs) W/O DU SHELF 300kg W/4 DU SHELF BBU CABINET 168kg (370lbs) W/O BATTERY 1136kg WITH BATTERY 22"x34" SCALE: NOT TO SCALE 1 1 "x17" SCALE: NOT TO SCALE OUTDOOR MMBS MECI iANCIAL SPECIFICATIONS 4 2211x34" SCALE: NOT TO SCALE 11 »x17" SCALE: NOT TO SCALE OUTDOOR BBU MECHANCIAL SPECIFICATIONS 5 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. Sprint rS A IMSU N G 13ENERAL DYNAMICS WIRELESS SERVICES PB TELECOM O }� 303 BATTERY STREET y SEATTLE, WA 98121 Ph 206.838.9275 u Q 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21 ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8 - 21 -1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: EQUIPMENT DETAILS OUTDOOR SPECIFICATIONS SHEET NUMBER: A 7 REVISION: B 1 120049 MANUFACTURER: RFS MANUFACTURER: COMMSCOPE GPS-TMR-HR-26NCM MODEL: APXVRRI3-C-A20 MODEL: HBXX-9014DS-A2M UNIT WEIGHT: 32.0 LBS WEIGHT: 29.8 LBS DIMENSIONS: 54.8" X 13.8" X 4.3" DIMENSIONS: 50.9" X 12.0" X 6.5" FREQUENCY: REFER TO RF DATA SHEET FREQUENCY: REFER TO RF DATA SHEET 13.8 4" 4.3" " MAX 12.0" 46.5 " 12.0" �� MAX 13.8" GPS-TMG-LMNT ANTENNA MOUNT ATTACHED TO 1 "b PIPE 1 " DIA SCH. 40 STAINLESS ISTEEL OF GALV.PPE MINIMUM OF 75% OR GPS OBSTRUCTIONS 270` IN ANY DIRECTION MUST BE BELOW d 15° TOP TOP GPS cq c� _ o 0 Ln NOTES: 1. THE GPS ANTENNA MOUNT IS DESIGNED TO FASTEN TO A STANDARD 1"0, SCH. 40, GALVANIZED STEEL OF STAINLESS STEEL PIPE. THE PIPE MUST NOT ® o 0 0 ® C° ®®®o• BE THREADED AT THE ANTENNA MOUNT END. THE PIPE SHALL BE CUT TO THE REQUIRED LENGTH (MIN. OF 18", 8'-0" IF MOUNTING TO NEW RF CONNECTOR, TYP O RF CONNECTOR, TYP o MMBS-BBU) USING A HAND OR ROTARY PIPE CUTTER TO ASSURE A SMOOTH AND PERPENDICULAR CUT. A HACK SAW SHALL NOT BE USED. THE CUT PIPE BOTTOM BOTTOM END SHALL BE DEBURRED. 2. IT IS CRITICAL THAT THE GPS ANTENNA IS MOUNTED SUCH THAT IT IS WITHIN RF CONNECTOR, TYP RF CONNECTOR, TYP 2 DEGREES OF VERTICAL AND THE BASE OF THE ANTENNA IS WITHIN 2° OF T!1- LEVEL. REMOTE ELECTRICAL FRONT SIDE REMOTE ELECTRICAL DOWNTILT ACTUATOR, TYP DOWNTILT ACTUATOR, TYP FRONT SIDE 3. DO NOT SWEEP TEST GPS ANTENNA 4. ATTACH GPS MOUNTING PIPE TO NEW MMBS-BBU USING (4) 8MMx15MM SS ANTENNA INFORMATION ANTENNA INFORMATION BOLTS AND (4) 1" PIPE STRAPS. GPS TO BE MOUNTED A MIN. OF 2'-0" PULLED FROM PRELIMINARY PULLED FROM PRELIMINARY ABOVE MMBS-BBU CABINET. PRODUCT DATA SHEET PRODUCT DATA SHEET 22"x34" SCALE: NOT TO SCALE j 22"x34" SCALE: NOT TO SCALE 1900 ANTENNA DETAIL 22;'x34;' SCALE: NOT TO SCALE BPS UNIT PIPE MOUNT 3 22"x34" SCALE: NOT TO SCALE GPS REQUIREMENTS 4 1900 ANTENNA DETAIL 1 1 1 "x17" SCALE: NOT TO SCALE 1 1 x17 SCALE: NOT TO SCALE 1 1 "x17' SCALE: NOT TO SCALE 1 1 x1 i SCALE. NOT TO SCALE S66M BLOCK FOR UDA z— GPS SURGE ARRESTOR DROOM COMSEAL -MARKER:ROXTEC POLE NEW 1900 ANTENNA, MOUNTING BRACKET BY MFR; ORIENT PER PLAN J3� BATTERY #1 BATTERY #0 RRH GAMMA AC/GROUND RRH BETA RRH ALPHA PORT LAYOUT DETAIL UDA OR BH CABLE ENLARGED TO SHOW NOTES NEW ANTENNA MOUNT 8 A-9 -P/N:COMSEAL 16/16 — GPS CABLE O` MUDR-OOM DETAIL ENLARGED TO SHOW NOTES 0 I O O O NEW MMBS-BBU NEW MMBS-BBU CABINET CABINET NEW 1900 RRU, MOUNTING BRACKET BY MFR; ORIENT PER PLAN ® 2" LB HOUSING INTO r — T MUDROOM O I ANTENNA NEW SST TOWER I SEE MUDROOM MOUNTING STANDOFF ANDREW DETAIL O 2" SEAL TIGHT O I PIPE TYPE SST-34 MUDROOM 2" LB HOUSING INTO CONDUIT FOR HYBRID MUDROOM I SUPPORT TO CABLEW P/N #8436 ANTENNA MOUNT 2" HEAVY WALL I COAX PIPE OR MOUNT / JUMPER, TYP SEE PORT LAYOUT ❑ COUPLING DETAIL 2" HEAVY WALL BLOCKS WITH BLOCKS COUPLING 2" SEAL TITE FLEXIBLE I NEW RET I / O I CABLE I y2" SS BAND O CONDUIT TO NEW 2" SEAL TITE EQUIPMENT I ] STRAIGHT CONNECTOR / NEW BREAKOUT UNIT, 2" SEAL TITE STRAIGHT I NEW JUMPER I / TYP OF (1) PER SECTOR 2" HEAVY WALL CONNECTOR I CABLE I / CONDUIT COUPLING I I // COLOR CODE BAND SEE PORT O O I------------------- NEW HYBRID FANOUT CABLE LAYOUT DETAIL 2 SEAL TITE FLEXIBLE CONDUIT NEW UNIVERSAL EQUIPMENT PLATFORM EQUIPMENT PLATFORM COAX STRAIN RELIEF ANGLE ADAPTER A-9 NEW BUTTERFLY SEAL TIGHT STRAIGHT 6"0 CONDUIT CONDUIT HANGERS CODUPLING P/N #88412 2" SCH 80 PVC FROM TELCO BOX 2" HEAVY INTO MUDROOM WALL CONDUIT MICROFLECT PIPE KIT P/N #B2127 MICROFLECT ANGLE REAR VIEW ADAPTOR P/N *8-157 W/ %" SIDE VIEW GALV. ALL THREAD 22"x34" SCALE: NOT TO SCALE g� AND TELCO LINE SUPPORT DETAIL 5 22"x34" SCALE: NOT TO SALE TYPICAL 1900 ANTENNA/ RRU MOUNTING DETAIL HYBRID 1 1 "x1 7" SCALE: NOT TO SCALE 11 "x17" SCALE: NOT TO SCALE THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO CARRIER SERVICES IS STRICTLY PROHIBITED. �r I Sproint } rS A Im s u GENERAL DYNAMICS WIRELESS SERVICES PB TELECOM 303 BATTERY STREET A SEATTLE, WA 98121 ph 206.838.9275 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21 ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8- 2 1- 1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: A-8 REVISION: B 120049 24" ± NOTES: 1. EXCAVATE TO REQUIRED DEPTH 2. VERIFY ALL TRENCHING REQUIREMENTS WITH PROJECT MANAGER. 3 CALL BEFORE YOU DIG!! CONTACT LOCAL UTILITY COMPANY ANCHOR SCHEDULE BOLT DIA. HOLE DIA. "E" EMBEDMENT 3/8" 3/8" 2" 1 /2" 1 /2" 3" 5/8" 5/8" 3 1 /8" 3/4" 3/4" 3 3/4" EXISTING CONC. 1 BOLT-TZ CB-TZ FOR APPLICATION NOTES: 1. THE CONTRACTOR SHALL ACCURATELY LOCATE ALL EXISTING REINFORCING BY X-RAY OR EQUIVALENT METHODS. NO REBAR OR TENDONS SHALL BE CUT. ALL EXPENSES RELATED TO REPAIR OR CUT REBAR OR TENDONS SHALL BE ENTIRELY AT THE EXPENSE OF THE CONTRACTOR. 2. SPECIAL INSPECTION IS REQUIRED FOR (HILTI KWIK BOLT-TZ PER ESR-1917) CONCRETE EXPANSION ANCHORS AGAINST SEISMIC. 3. INSTALLATION OF WEDGE ANCHORS IN MASONRY IS NOT ALLOWED. 4. VERIFY WITH CABINET MANUFACTURER FOR MOUNTING HOLE LOCATIONS. m RIGID STEEL CONDUIT RIGID STEEL CONDUIT PLUG GID STEEL CONDUIT COUPLING FINISH GRADE RIGID STEEL TO PVC ADAPTER PVC CONDUIT PER PLAN ANTENNA MOUNT 6 NEW ANTENNA A-g PIPE MOUNT NEW L1 x2.5 NEW 3/8" 0 GALV U-BOLT, TYP OF 2, TOP & BOT NEW L1 x2:5 2'-0" NEW L1 x2.5 (TEMPORARY STANDOFF) TO BE REMOVED WHEN COMA ANTENNAS ARE REMOVED EXISTING CDMA ANTENNA PIPE MOUNT (2"0) NEW 3/8" 0 GALV U-BOLT, TYP OF 2, TOP & BOT 22"x34" SCALE: NOT TO SCALE CONDUIT TRENCH 1 22"x34" SCALE: NOT TO SCALE CABINET ANCHOR DETAIL � 22"x34" SCALE: NOT TO SCALE CONDUIT STUB -LIP 3 22"x34" SCALE: NOT TO SCALE TEMP. ANTENNA MOUNT 4 1 1 %17" SCALE: NOT TO SCALE 1 1 %17" SCALE: NOT TO SCALE 1 1 "x17" SCALE: NOT TO SCALE 1 1 "x1 7" SCALE: NOT TO SCALE NOTES 1. MULTIPLE CONDUITS CAN BE PLACED IN THE SAME TRENCH AS LONG AS A MINIMUM SEPARATICN PER THE LOCAL UTILITY COMPANIES IS MAINTAINED. IN ALL CASES THE MINIMUM CENTER TO CENTER SPACING BETWEEN CONDUITS IS 1'-0" (NOT REQUIRED FOR COAX). 2. CONTRACTOR SHALL RESTORE THE TRENCH TO ITS ORIGINAL CONDITIONS BY EITHER SEEDING OR SODDING GRASS AREAS. OR REPLACING ASPHALT OR CONCRETE AREAS TO ITS ORIGINAL CROSS SECTION. 3. IF SAW CUT IS NEEDED, OVER CUT BOTH SIDES OF TRENCH BY MINIMUM OF 6" TO AVOID DEPRESSION IN THE FUTURE FINISHED GRADE OR AC 2'-6"f PAVING MATCH SLOPE & THICKNESS OF EXISTING �— COMPACTED BACKFILL— TO MIN 95% MODIFIED MAX. DENSITY PER ASTM D1557 METHOD D UNDISTURBED EARTH--- TELCO/LOW VOLTAGE CONDUITS �t- 7� NOTE: SEE STRUCTURAL DETAILS AND CALCULATIONS FROM MOUNT MFR "" ^'_L-THRE,gDI TYP POLE BENT PLATE WITH 23/8" OD GALV PIPE WELDED TO STANDOFF HYBRID CABLE,— 1 PER SECTOR /j -H w m z SLIP-ON HOISTING GRIP J 5"CLR UTILITY o WARNING z_ w TAPE :2 CONDUIT �o \--POWER CONDUITS 1'-0" MIN. CLEARANCE SAND BEDDING Fi UTILITY TRENCH "x34" SCALE: NOT TO SCALE 22"x34' SCALE NOT TO SCALE CO/ 1/� H/1NER "x17" SCALE: NOT TO SCALE 5 1 1 "x17" SCALE: NOT TO SCALE SEAL PERIMETER BASE OF CABINE' CONTINUOUS BEAD OF WATERPROOF SE 2 CABINET A A-9 4" #57 WASHED STONE MATERIAL ON LANDSCAPE WEED BARRIER OVER WELL COMPACTED FILL ED CONC PAD (3,500 PSI) :A WAY, 3" MIN CLR D EDGE DENSITY CLEAN ,TED FILL cD z w 0 0 w O O 0 w c ANTENNA (REFERENCE) R R U (REFERENCE) /-TRIM TRIM PIPE MOUNT (AS REQ'D) TO MAINTAIN SEPARATION FROM TRANSMISSION LINES AND/OR REDUCE VISUAL IMPACT 22"x34" SCALE: NOT TO SCALE EQUIPMENT CONCRETE PAD i 22"x34" 1 "x17" SCALE: SCALE: NOT NOT TO TO SCALE SCALE ANTENNA MOUNT DETAIL 8 1 1 "x17" SCALE: NOT TO SCALE 1 Sprint"10 rSWA M S!U N g AG GENERAL DYNAMICS WIRELESS SERVICES Q ; PB TELECOM 303 BATTERY STREET (cl P SEATTLE, WA 98121 Ph 206.838.9275 206.838.5021 PROJECT INFORMATION: NETWORK VISION MMBS LAUNCH GUINNESS SE63XC311 32535 21ST AVE SW FEDERAL WAY, WA 98032 KING COUNTY ISSUE DATE: 0 8— 2 1— 1 2 ISSUED FOR: PREL 100% CD SUBMITTAL REVISIONS REV. DATE DESCRIPTION INITIALS A 08/10/12 ISSUED FOR 90% CD SUBMITTAL JLA B 08/21 /12 ISSUED FOR PREL 100% CD SUBMITTAL JLA NOT FOR CONSTRUCTION UNLESS LABELED AS CONSTRUCTION SET LICENSURE: SHEET TITLE - EQUIPMENT DETAILS SHEET NUMBER: A-9 REVISION: B 120049 THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION UUGUMLNI5 IS- PRUPRIEIAKY BY NAIUKL. ANY UJL UK UIJI.LUJUKL UINLK lnHiv inHi vvr-M n fCCLH LJ IU l,l-W NILJ\ JLI\VIULJ IJ JI1\Il L rI\VIit ]1 L1.