03-102156-ADCITY OF CITY HALL 33530 1 st Way South PO Box 9718 June 12, 2003 Ms. Jennifer Dowrey JPC Architects 355 110th Avenue NE, Suite 100 Bellevue, WA 98004 a�V - (253) 661-4000 Federal Way, WA 98063-9718 Re: File #03-102156-00-AD; RESPONSE TO INQUIRY Evergreen Bank; 1300 South 320"' Street, Federal Way, WA Dear Ms. Dowrey: This letter is in response to your May 27, 2003, inquiry about the review process for proposed site and fagade changes at the future Evergreen Bank at the above referenced address. Your letter proposes the removal of parking stalls and landscaping along the east side of the building in order to install a drive -through linked to an ATM and night deposit slot. Parking stalls would be relocated throughout the site. The building is located within the City Center Frame (CC-F) zoning district. Pursuant to Federal Way City Code (FWCC) Section 22-32.2, improvements to an existing developed site shall be processed using Use Process I, Directors Approval, provided that the improvements and or additions do not exceed any of the thresholds of FWCC Section 22- 32.2(1)(a-fl (enclosed). If any one of the thresholds is exceeded, Process 11 Site Plan Review would be required. Process I is hourly land use review procedure, with fees of $57.50 due. Process II is a flat fee land use review procedure with a one-time fee of $1,716.50. The drawing provide-0 depicts removal of interior parking lot landscape areas associated with eliminated parking stalls. This interior parking lot landscaping is required,under the FWCC in quantities of 20 square feet of interior parking lot landscaping per parking stall. In addition, the drawing depicts changes to material changes to the parking stalls as the 60-degree parking stalls are moved and replaced with parallel parking stalls set against the property line. These changes exceed the thresholds of Process I, and must therefore be reviewed under Process II, Site Plan Review. I have enclosed a Development Checklist marked for the Process II application and a Master Land Use Application that must be submitted for the project. Ms. Jennifer Dowrey Page 2 June 12, 2003 In submitting the Process II application, please be aware of the following standards of the FWCC. Copies of referenced sections are enclosed. • Relocated parking stalls must be screened from the 320`h Street right-of-way in conformance with FWCC Section 22-1567(e)(1). e Perimeter landscaping five feet in width may be required around the project bite in conformance with FWCC Section 22-1564. • The minimum number of parking stalls for the project is 25, per FWCC Section 22- 804, "Retail Uses" (one parking stall for each 300 square feet of gross floor area). • Interior parking lot landscaping is required at the ends of relocated parking stalls and throughout the site to meet the intent of FWCC Section 22-1567(b). • Drive -through facilities shall meet the standards of FWCC Section 22-1634(g)(2)(a) and (b), and shall be physically separated from the parking lot, sidewalk, and pedestrian areas by Type III landscaping and/or an architectural element. Painted lanes are not sufficient. • The Federal Way Public Works Department will review the proposed drive -through to ensure conformance with FWCC Section 22-804, note 5. I can be reached at 253-661-4103 if you have any questions about this letter. We look forward to working with you. Sincerely, Deb Barker Associate Planner enclosures File H03-102156-00-AD Doc. I.D. 23471 eJPC ARCHITECTS TRANSMITTAL aC� J To: Greg Fewins Company: City of Federal Way Address: 33530 15 Way South City/State: Zip: Phone: Federal Way 98003 253-661-4000 ext. 0 We are sending you the following. Prints Dear Mr. Fewins, -*03-I40gl5� ';�o-.40 FILE VqfW 130Q S• 3 Zd 73 JT Date: 05-27-03 Project Name: Evergreenl3ank Project No: 03-100-0158 Regarding: Site plan and Elevation Attached RECEIVED For Your: Information and Use MAY 2 8 2003 Action Required: As Indicated Delivery: Courier Ci et°ti�ING DEPTERAL NAY Attached is a site plan and elevation showing proposed demolition of parking curbs and plantings, as well as a new drive -up ATM and Night drop installed as shown on plan. We would like to determine if a full site plan review is necessary and/or what steps are needed to obtain a permit for this work. Please provide us with as much information as you can that would help us complete the process of application. Sincerely, Jennifer Dowrey JPC ARCHITECTS, PLLC Cc: Dennis Dieni, JPC Architects Judith Moratti, Pemco Insurance 355 110th Ave NE - Suite 100 Bellevue, WA 98004 tel [425] 641-9200 fax [425] 637-8200 www.jpcarchitects.com Transmit T U Z t FIN. FLO �E 0 0 (N) CONC. CURB SEE DWG. IA1.1 — EAST ELEVATION Scale: 1 /4"=1 '-0" JPC ARCHITECTS 355 110th Ave NE - Suite 100 Bellevue, WA 98004 to I [425] 641-9200, , fax [425] 637-8200 NIGHTI ATM DRC�P� w r r NEW WINDOW AND MULLION TO MATCH EXISTING REMOVE STORE —FRONT GLASS AND MULLIONS LOCATION OF DRIVE —UP ATM AND NIGHT DROP WITH 84"X84" ENCLOSURE BY OTHERS. EVERGREENBANK JPC PROJ MGR: DD JPC PROJ NO.: 03-100-0158 REVISION: SP — 05-27-03 BUILDING: © 2003, JPC ARCHITECTS PLLC 05-27-03 A-1