Loading...
21-105126City of Federal Way Community Development Dept 33325 8th Ave S Federal Way, WA 98003 Ph: (253) 835-2607 Fax: (253) 835-2609 Project Name Project Address Project Description Building - Multi Family Permit #:21-105126-00-MF Inspection Request Line: (253) 835-3050 FEDERAL WAY MIXED USE @ 348TH - BUILDING D 34816 1ST AVE S Parcel Number: 912940 0010 BLUEBEAM - New construction of a 13,392 square foot three-story walk-up apartment building containing 12 for -rent apartment units. Includes plumbing and mechanical. Owner Applicant Contractor Lender X MARKS THE SPOT LLC BRETT JACOBSENX MARKS THE F N W INC KATHLEEN BROWN '1 I WEST VALLEY HWY SUITE 21 SPOT LLC 711 WEST VALLEY HWY SUITE 20 SANDERSUMPQUA BANK AUBURN WA 98001 711 WEST VALLEY HWY SUITE 2( AUBURN WA 98001 1111 3RD AVE SUITE 2900 AUBURN WA 98001 SEATTLE WA 98101 Census Category: 105 - New 5- or More Family Building Includes: # 1 92 #3 94 Occupancy Class: R-2 Construction Tv e: Type V - B Occupancy Load: Floor Area (sq. ft.) 13,392.00. Additional Permit Information New / Additional Sq. Feet - 1 st Floor ..................... 13392 Occupancy # 1 - Area (Sq. Feet).............................. 13392 Occupancy #1 -Construction Type ......................... Type V - B Mechanical to be Included?..................................... Yes Plumbing Work Valuation? ..................................... 82000 Mechanical Work Valuation?.,.............. 200000 Number of Stories........... .................................,....., 3 is this an Online or O.T.C. application?.................. No Permit for Building Shell Only?........... ................... No Plumbing to be Included?........................................ Yes New / Additional Sq. Feet - Total ........................... 13392 Will Certificate of Occupancy be Issued?............... Yes Occupancy #1 - Use ............................................. Apartment House Comprehensive Plan Designation ....... a................... Community Business Zoning Designation ................................................. BC Total Valuation: 1,449,581.00 Mechanical Fixtures Air Handling Units 2 Air Conditioners - Stand Alont 30 Ducting 1 Fans 42 Furnaces 12 Plumbing Fixtures t�=r77 r� Bathtubs 18 Dishwashers 12 Laundry Washer Outlets 12 Lavatories 18 Sinks 12 Water Closets 18 Water Heaters 12 Hose Bibbs 2 CONDITIONS: Fire conditions: A separate permit is required for the following: Fire underground Fire alarm Fire sprinkler Swing check for FDC (if not wall mounted) shall be in a vault. FDC shall be a 5" Storz connection with Knox locking cap A recessed Knox box is required in an approved location. An Opticom sensor is required on all driveway access gates for emergency personnel. Fire lanes shall be marked in accordance with required standards. Fire extinguishers are required at 75' travel distance. Before issuance of any Certificate of Occupancy, critical area fencing, and signage shall be installed per FWRC 19.145.180(2) and (3)(a)(iv). Site wayfinding signage shall be installed prior to the first building permit final inspection requested for the site. Prior to issuance of a Certificate of Occupancy for the first residential building, an agreement in a form approved by the city requiring affordable dwelling units to remain as affordable housing for the life of the project must be recorded with the King County Recorder's Office by the applicant. PERMIT EXPIRES Monday, 27 March, 2023 Permit Issued on Wednesday, September 28, 2022 I hereby certify that the above information is correct and that the construction on the above described property and the occupancy and the use will be in accordance with the laws, rules and regulations of the State of Washington and the City of Federal Way. Owner or agent: = Date City of Federal Way Certificate of occupancy This Certificate issued pursuant to the requirements of Section 111 of the International Building Code or Section R110 of the International Residential Code is certifying that at the time of issuance, this structure was in compliance with the various ordinances of the City regulating building construction or use. This certificate is valid ONLY when endorsed by City staff. Tenant Name: FEDERAL WAY MIXED USE @ 348TH - BUILDI Address: 34816 1ST AVE S Bldg D Includes: #1 92 #3 Occupancy Class: R-2 Construction Type: Type V - B Occupancy Load: Floor Area (sq. ft.) 13,392.00 Owner Name: X MARKS THE SPOT LLC Owner Address: 2711 WEST VALLEY HWY SUITE 20C 01 Permit # 21-105126-00-MF #4 l h'5 Date The priority focus in Ke review and inspection made by the City prior to issuance of this Certificate was on those matters which experience has shown most severely affect the health and safety of the general public. Although the City has made as complete a review and inspection as is reasonably possible (within budgetary time and personnel limitations), the City neither guarantees nor warrants to the owner/ occupant or to any other person that this Certificate evidences strict compliance with each and every ordinance or regulation of the City or the State of Washington affecting the construction or use of said structure or the land upon which it is situated. Such compliance is the responsibility of the owner and / or occupant of the premises. 4&:r CITY OF Federal Way PERMIT #: Project: THIS CARD IS TO REMAIN ON -SITE Construction Inspection Record INSPECTION REQUESTS: (253) 835-3050 21 105126-00 Address: 34816 1ST AVE S Bldg D X MARKS THE SPOT LLC FEDERAL WAY WA 98003 Scheduled inspections may be failed if this card is not on -site. DO NOT LOSE THIS CARD. Inspections are listed as close to sequential order as possible (read left to right, top to bottom). Please schedule inspections as appropriate. Work must not be covered until it is approved. Check with your inspector if you are unsure about any of the inspections or the inspection sequence. On -going inspections are logged on the back of this card. Q Footings/Setback (4110) '�- Foundation Wall (4115) Drainage/Downspout (4040) Approved to place concrete Approved to place concrete Approved to backfill By Date By Date By Date El Re -steel (4215) 5❑ Plumbing Groundwork (4190) Slab/Concrete Floor (4255) Approved to place concrete or grout Approved to cover Approved to place concrete By Date By Date By Date 0 Underfloor Framing (4285) ® Floor Sheathing (4105) Shear Walls (4245) Approved to sheath floor Approved to install flooring Approved to install sidin By Date By Date By 0 Date 90 Roof Sheathing (4220) 11 Rough Plumbing (4230) 12 Mechanical Rough -in (4165)�� Approved to install roofing Approved Approved By Date By Date 3 2ai z By Date L110/ � 13 Gas Piping (4125) Approved to release test By Date Q Fire/Draft Stops (4095) Approved By \3 Date L r to scheduling a Framing inspection; ical, Plumbing &Mechanical Rough -in e/Draft Stop inspections must be signed - off and approved. IBC 109.3.4 5 Framing (4120) 16 Insulation (4150) Gypsum Wallboard Nailing (4130) Approved to insulate Approved to install wallboard Approved to install mud K tape 'Ff% By J� Date G By Date 1/ By 7 (3 Date ti I t g Suspended Ceiling Grid (4265) El Final - S K F & R (4060) 2fl Final -Planning Approved to drop tile Approved Approved By Date By Date By Date EJ Final - Public Works (4080) 22 Final - Mechanical (4065) '-3 Final - Plumbing (4075) Approved Approved Approved �l� By Date By 1J.C) Date 1 LL ^ f By Date I ?/� 24 Final - Building (4050) �i fa�?/ j �r 1 ek '' Vf�_%/k P - Q V— Approved '� i�� Q �� �Cr ty- l' I!1 By G Date (� 7i( 1 �C�� 7i`1 1 0" �1 10/n -30 -- �w3 ��� Rough Electrical Final Electrical Right of Way Approved Approved Approved By Date By Date By Date CITY OF Building Division Federal 1lVa decal Eighth Avenue South Federal Way, WA 98003-6325 Phone 253-835-2607 Fax 253-835-2609 CORRECTION NOTICE ADDRESS: �`��{ ��f AVC�� P RMIT#: _7 IF YOU HAVE QUESTIONS CALL (253) 835 zca - WHEN CORRECTIONS HAVE BEEN MADE, CALL (253) 83 3050 FOR RE -INSPECTION. SEE BACK OF CARD FOR DETAILS. NOTE: ELECTRICAL CORRECTIONS ARE REQUIRED TO BE MADE WITHIN 15 DAYS. Jo DATE INSPECTOR DO NOT REMOVE THIS NOTICE Page of