21-104203 (2)41k
CITY OF
Federal Way
PERMIT NUMBER _
PERMIT APPLICATION
PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325
253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com
TARGET DATE
SITE ADDRESS
SUITE/UNIT #
2211 S. Star Lake Road, Federal Way, WA 98003
PROJECT VALUATION
ZONING
ASSESSOR'S TAX/PARCEL #
$ 15,000
7204800095 -
TYPE OF PERMIT
ER BUILDING ❑ PLUMBING ❑ MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION
NAME OF PROJECT
AVANA -STAR LAKE APARMTMENTS- LIMITED AMENITIES REMODEL
PROJECT DESCRIPTION
Detailed description of work to
Existing Interior Pool building, remove non bearing interior wall to expand bike storage.
be included on this permit only
NAME
PRIMARY PHONE
Avana Star Lake Apartments -C/O Greystar
408-209-9616
PROPERTY OWNER
MAILING ADDRESS
450 Sansome Street
E-MAIL
bgiffin@greystar.com
CITY
San Francisco
STATE
Ca
ZIP
94111
NAME TBD
PHONE
MAILING ADDRESS
E-MAIL
CONTRACTOR
CITY
STATE
ZIP
FAX
WA STATE CONTRACTOR'S LICENSE #
EXPIRATION DATE
UBI #
NAME Charles Pick, Architect
PRIMARY PHONE
415-233-3778
APPLICANT
MAILING ADDRESS
2130 Fourth Street, Suite B
E-MAIL
cpick@basisarch.com
CITY
San Rafael
STATE
Ca
ZIP
94901
FAX
PROJECT CONTACT
NAME
Robert Mackey -Project Manager
PRIMARY PHONE
415-302-2914
MAILING ADDRESS 2130 fourth Street, Suite B
E-MAIL
rmackey@basisarch.com
(The individual to receive and
respond to all correspondence
CITY San Rafael
STATE
ZIP
FAX
concerning this application)
Ca
94901
PROJECT FINANCING
NAME
Brian Giffin- Greystar
❑x OWNER -FINANCED
When value is $5,000 or more
(RCW 19.27.095)
MAILING ADDRESS, CITY STATE, ZIP
450 Sansome St, fan Francisco, Ca 94111
ONE
408-209-9M
I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best
of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with
all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the
issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating
construction or environmental laws.
I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in
the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city,
but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the
information supplied to the city as apart of this application.
SIGNATURE: DATE 10-4-2021
PRINT NAME: Charles Pick
Bulletin #100 - February 19, 2020 Page 1 of 2 k:AHandouts\Permit Application
MECHANICAL PERMIT
Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existiggfixtures to remain.
AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe)
AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial)
BOILERS FURNACES HOT WATER TANKS (Gas)
COMPRESSORS GAS LOG SETS REFRIGERATION SYST
DUCTING GAS PIPING WOODSTOVES
PLUMBING PERMIT
Indicate how many of each type offixture
to be installed or relocated as
part of this project. Do not include existing fixtures to remain.
BATHTUBS (or Tub/shower combo)
LAVS (Hand Sinks)
TOILETS WATER PIPING
DISHWASHERS
RAINWATER SYSTEMS
URINALS OTHER (Describe)
DRAINS
SHOWERS
VACUUM BREAKERS
DRINKING FOUNTAINS
SINKS (Kitchen/Utility)
WATER HEATERS (Electric)
HOSE BIBBS
SUMPS
WASHING MACHINES TOTAL FIXTURES
GENERAL INFORMATION
CRITICAL AREAS ON PROPERTY?
WATER PURVEYOR
SEWER PURVEYOR
VALUE OF EXISTING IMPROVEMENTS
EXISTING/PREVIOUS USE
LOT SIZE (In Square Feet(
EXISTING FIRE SPRINKLER SYSTEM?
PROPOSED FIRE SUPPRESSION SYSTEM?
36.9 Acres
❑ Yes ® No
❑ Yes X No
RESIDENTIAL - NEW OR ADDITION
AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE
...............................................................................................................................
BASEMENT
...............................................................................................................................
FIRST FLOOR (or Mobile Home)
...............................................................................................................................
SECOND FLOOR
...............................................................................................................................
COVERED ENTRY
...............................................................................................................................
DECK
...............................................................................................................................
GARAGE ❑ CARPORT ❑
...............................................................................................................................
OTHER (describe)
...............................................................................................................................
Area Totals EXISTING PROPOSED TOTAL
**NEW HOMES ONLY"
LESTIMATED SELLING PRICE $ # OF BEDROOMS
COMMERCIAL - NEW/ADDITION
AREA DESCRIPTION
Area in
Square Feet
Occupancy Group(s)
Construction
Type
# of
Stories
Additional Information
NEW BUILDING
ADDITION
COMMERCIAL - REMODEL/TENANT IMPROVEMENTS
AREA DESCRIPTION
Area in
Square Feet
Occupancy Group(s)
Construction
Type
# of
Stories
Additional Information
TOTAL BUILDING
TENANT AREA ONLY
PROJECT AREA ONLY
195 SF
B-2
V-A
Bulletin #100 — February 19, 2020 Page 2 of 2 k:\Handouts\Permit Application
AVANA�STAR LAKIE
OWNER/CLIENT
MECH/ELEC/PLUMBING ENGINEER
AVANA STAR LAKE APARTMENTS
ACIES ENGINEERING
C/O GREYSTAR
400 N. McCRATHY BLVD
450 SANSOME STREET
SUITE 250
LIMITED AMENITIES RLMODLL
SANFRANC16 CA94111
Brian Giffin
95035
Milan Pesakovic,PE
A.C.
AIR CONDITIONING
LAM.
LAMINATE
408
408-209-9616
PH:408-5 2-
PH: 408-522-5255 x123
ACOUS.
ACOUSTICAL
LAV.
LAVATORY
bgiffinCgreystar.com
email: milanCacies.net
A. F.
A.F.F.
ADJUSTABLE
ABOVE FINISH FLOOR
MAT.
MATERIAL
INDOOR POOL BUILDING
ARCHITECT
MAX.
MAXIMUM
BASIS ARCHITECTURE Et CONSULTING INC
ALUM.
ALUMINIUM
M.B.
MACHINE BOLT
2130 4TH STREET, STE. B
ANOD.
B
ANODIZED
BOARD
M.C.
(M)
MEDICINE CABINET
MODIFIED
2211 S STAR LAKL ROAD
SAN RAFAEL, CA 94915
Architect: Charles Pick
BLDG.
DG.
BUILDING
MIN.
MINIMUM
. '
415-233-3778
cpick@basisarch.com
BLKG.
BLOCKING
MIR.
MIRROR
B
BOTTOM
M
MISCELLANEOUS
FLDLRAL WAY NG COUNTY WA 98003
BM.M.
BEAM
L.
MTL.
METAL
CAB.
CABINET
CEM.
CEM.
CEMENT
CERAMIC
MTD.
(N)
N.I.C.
MOUNTED
NEW
NOT INCONTRACT
PARCLL #7204800095
TEAM INDEX
C.G.
CORNER GUARD
N0.
NUMBER
C.L.
CENTER LINE
CLG. CEILING NTE NOT TO EXCEED
CLR.
CLEARANCE
N.T.S.
NOT TO SCALE
CMU.
CONCRETE MASONRY UNIT
O.C.
ON CENTER
1. ALL WORK SHALL CONFORM TO THE FOLLOWING BUILDING CODES AND WASHINGTON
COL.
COLUMN
O.D.
OUTSIDE DIAMETER
STATE BUILDING CODE AMENDMENTS AND FEDERAL WAY MUNICIPAL CODES - BUILDING
AT INDOOR POOL BUILDING:
ARCHITECTURAL
CONC.
CONCRETE
O.H.
OVER HEAD
AND CONSTRUCTION, ADDITIONAL FEDERAL WAY REGULATIONS, AND NFPA STANDARDS.
CONST.
CONTR.
CONSTRUCTION
CONTRACTOR
PL.
PLAM.
PLATE
PLASTIC LAMINATE
2018 INTERNATIONAL BUILDING CODE
1. REMOVE EXISTING NON BEARING, NON RATED PARTITION IN (E)STORAGE AND DOOR TO EXPAND BIKE STORAGE.
AO COVER SHEET
2018 INTERNATIONAL FIRE CODE
A2.3 EXISTING/DEMOLITION INDOOR POOL BUILDING
PLAN
C.T.
CERAMIC TILE
PLYWD.
PLYWOOD
2018 INTERNATIONAL MECHANICAL CODE
CTSK.
COUNTERSINK
PSI
POUNDS/SQ. INCH
2O18 INTERNATIONAL FUEL GAS CODE
SCOPE NOTE:
A2.4 INDOOR POOL BUILDING PLAN
CTR.
CENTER
PT
PRESSURE TREATED
2018 UNIFORM PLUMBING CODE
DA
DISABLED ACCESSIBLE
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI 117.1)
A6.0 DETAILS
DBL.
DOUBLE
Q.T.
QUARRY TILE
2018 INTERNATIONAL EXISTING BUILDING CODE
. NO CHANGE TO EXISTING OCCUPANCIES, OCCUPANT LOAD, EXITS, OR RATED ASSEMBLIES.
D.F.
DOUGLAS FIR
R
RISER
WASHINGTON STATE AMENDMENTS
DET.
DETAIL
R)
( R)
REPLACE
DET.
DIAGONAL
REINFORCING
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS Et SHALL NOTIFY THE
INTERIOR DESIGN Et FINISH SHEETS
DIA.
DIAMETER
REQ'D
REQUIRED
ARCHITECT OF ANY DIMENSIONS Et CONDITIONS, WHICH DIFFER FROM THOSE SHOWN,
(SHOW DESIGN INTENT Et FINISH/FIXTURE SELECTIONS ONLY)
BEFORE STARTING WORK. DIMENSIONS GIVEN AS (CLR.) ARE CODE REQUIRED Et SHALL BE
DIM.
DIMENSION
REV.
REVISED
MAINTAINED.
2.1 FLOOR FINISHES
DN.
DOWN
RM.
ROOM
DR.
DOOR
RO.
ROUGH OPENING
3. ALL DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD. ALL DIMENSIONS
DWG.
DRAWING
RWL
RAIN WATER LEADER
FROM EXISTING CONSTRUCTION ARE FROM FACE TO FINISH, UNLESS OTHER WISE NOTED
(U.0.N.).
D.S.
DOWNSPOUT
SAD
SUPPLY AIR DUCT
(E)
EXISTING
SCHED.
SCHEDULE
4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED
EA.
EACH
SEC.
SECTION
DIMENSIONS. DIMENSIONS FOR EXISTING CONDITIONS Et ELEVATIONS MAY BE
ELEC.
ELECTRICAL
SHT.
SHEET
APPROXIMATE.
E.P.
ELECTRICAL PANEL
S&P
SHELF AND POLE
5. ALL INSTALLATIONS TO BE IN ACCORDANCE WITH BEST INDUSTRY STANDARDS Et
ELEV.
BUILDING ELEVATION
SL
SKYLIGHT
MANUFACTURER'S REQUIREMENTS, SEE ATTACHED SPECIFICATIONS.
EQ.
EQUAL
SIM.
SIMILAR
EXP.
EXPOSED
SPEC.
SPECIFICATION
6. ALL THE DRAWINGS SHOW REPRESENTATIVE Et TYPICAL ATTACHMENTS, CONNECTIONS,
EXT.
EXTERIOR
SQ.
SQUARE
FASTENINGS Et ETC. SHALL BE PROPERLY SECURED IN CONFORMANCE WITH BEST
F.FLR.
FINISH FLOOR
S.S.
STAINLESS STEEL
PRACTICE.
SCOPE OF WORK SUMMARY
FLASH
FLASHING
S.S.D.
SEE STRUCT. DRAWINGS
7. THE PLANS MAY OR MAY NOT BE BASED ON A SURVEY Et ARE INTENDED ONLY TO SHOW
F.O.F.
FACE OF FINISH
S.M.D.
SEE MECH. DRAWINGS
GENERAL LAYOUT OF PROPERTY Et WORK LOCATIONS. CONDITIONS SHOWN
F.0.5.
FACE OF STUD
STD.
STANDARD
APPROXIMATE.
FR.C.
FRENCH CASEMENT
STL.
STEEL
8• ALL WORK TO BE PAINTED TO MATCH (E), UNLESS OTHERWISE NOTED.
EXISTING APARTMENT BUILDINGS = 72 (2-STORY Et 3-STORY) - NO CHANGE
FTG.
FOOTING
STOR.
STORAGE
FX.
FIXED
STRUCT.
STRUCTURAL
9. ALL WORK SUBJECT TO ASSOCIATED PROJECT MANUAL SPECIFICATIONS AND
CONSTRUCTED: 1987 (PHASE 1), 1989 (PHASE II)
GA.
GAUGE
SUSP.
SUSPENDED
INSTRUCTIONS BY ARCHITECT.
LOT SIZE: 36.9 ACRES
GALV.
GALVANIZED
T.B.
TOWEL BAR
OCCUPANCY: B-2
GL.
GLASS
T.O.S.
TOP OF SLAB
10. ALL CONDITIONS ARE EXISTING UNLESS OTHERWISE NOTED.
CONSTRUCTION TYPE: TYPE V-A (NOWSPRINKLERED)
GR.
GRADE
TGL.
TEMPERED GLASS
HAZARDOUS MATERIALS IN EXISTING CONSTRUCTION
GWB.
GYPSUM WALL BOARD
TEtG
TONGUE AND GROOVE
BASIS ARCHITECTURE Et CONSULTING ASSUMES NO RESPONSIBILITY FOR THE MANAGEMENT OF
TOTAL UNITS = 750 UNITS (616,740 SF - NO CHANGE)
GYP.
GYPSUM
TYP.
TYPICAL
HAZARDOUS MATERIALS THAT MAY BE ON SITE. THE CONTRACTOR SHALL BE RESPONSIBLE
H.A.R.
HOT AIR REGISTER
U.B.C.
UNIFORM BUILDING CODE
FOR INSURING THAT PERSONNEL WITHIN THE WORK AREA ARE PROTECTED FROM EXPOSURE
TYPE 1: 1 BED/1 BATH = 584 SF (122 UNITS)
HDR.
HEADER
TO HAZARDOUS MATERIALS. IF MATERIALS ARE DISCOVERED THAT MAY BE HAZARDOUS, THE
TYPE 2: 1 BED/1 BATH = 640 SF (188 UNITS)
U.O.N.
UNLESS OTHERWISE NOTED
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND CEASE WORK UNTIL CONDITIONS
TYPE 3: 2 BED/1 BATH = 788 SF (64 UNITS)
HGR.
HANGER
V.G.
VERTICAL GRAIN
CAN BE MAINTAINED IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS.
TYPE 4: 2 BED/1 BATH = 866 SF (48 UNITS)
HDWD.
HARDWOOD
VERT.
VERTICAL
TYPE 5: 2 BED/1 BATH = 912 SF (84 UNITS)
HORZ.
HORIZONTAL
TYPE 6: 2 BED/2 BATH = 970 SF (112 UNITS)
HT.
HEIGHT
V.I.F.
VERIFY IN FIELD
TYPE 7: 3 BED/2 BATH = 1,037 SF (72 UNITS)
HVAC.
HEATING, VENTILATING
W/
WITH
TYPE 8: 3 BED/2 BATH = 1,221 SF (60 UNITS)
INT.
INTERIOR
WC
WATER CLOSET
INST.
INSTALLATION
WD.
WOOD
LEASE OFFICE/COMMUNITY BUILDING = 6,143 SF (1-STORY) - NO CHANGE
INSUL.
INSULATION
W•P.
WATERPROOF
GENERALNOTES, CODE INFO
INDOOR POOL BUILDING = 3,759 SF (1-STORY) - NO CHANGE
Olv
CABANA BUILDING = 1,954 SF (1-STORY) - NO CHANGE
PARKING = 1,262 PARKING SPACES (INC. 21 ADA SPACES) - NO CHANGE
EXTERIOR PARKING LOT = 950 - OPEN SPACES
176 - CARPORT SPACES
136 - DETACHED GARAGE SPACES
ABBREVIATIONS
DEFERRED SUBMITTALS
PROJECT DATA
SHEET INDEX
Safeway
..
'.'
a Murphy's I Take`
'N
J'
.
Bake ... Little Caesars, Pi=a
y
S 272nd St S 272nd St
S 272nd-St S 272nd St
^'
S 273r�d^S-
,.
:; •. _'
,,�,,,.. v ; " i •
Ar..
dRd EmeCu�ireha
C'. ub Palisades`I,—J
Avana r Lake
sfa.
�a,��, � k-Twain
Rd Elementary School e_,J
r.
4
`
I
76th Si
.r
6 -
MIR
T
UnEarthetl skin care studio i,,�
500 feet
PROJECT LOCATION
O
PHOTO - EXISTING
CONDITIONS
VICINITY MAP
NORTH
BASISArchitecture
&Consulting
2130 FOURTH ST
SAN RAFAEL, CA 94901
PHONE (415) 457-6035
CHARLES PICK, ARCHITECT
�252 FEGISTERED
RCHITECT
IHAR �ICK
STATE OF WASHINGTON
■�■�■�■�■�■
DESIGNATED PATH OF TRAVEL
PAVING IMPROVEMENTS
a a
(N) CONCRETE (V.I.F.)
i
(N) GRADING
(E) WALL TO REMAIN
(E) WALL TO BE REMOVED
(N) INTERIOR PARTITION
(N) 1 HOUR RATED WALL
PERMIT #21-104203
DRAWING REVISION LOG
FOR ISSUE 19-22-2021
/16/2 1
:TTOF FEDE
MUNITY DEVELOPMENT
PROJECT NAME:
AVANA STAR LAKE
LIMITED AMENITIES
REMODEL
PROJECT LOCATION:
2211 S. STAR LAKE RD.,
FEDERAL WAY,
KING COUNTY, WA
98003
SHEET TITLE:
COVER SHEET
Copyright 2021 by Charles Pick, Architect and Basis Architecture Et Consulting Inc.