Loading...
21-104204 (2)41k CITY OF Federal Way PERMIT NUMBER _ PERMIT APPLICATION PERMIT CENTER + 33325 81h Avenue South + Federal Way, WA 98003-6325 253-835-2607 + FAX 253-835-2609 + permitcenter@cityoffederalway.com TARGET DATE SITE ADDRESS SUITE/UNIT # 2211 S. Star Lake Road, Federal Way, WA 98003 PROJECT VALUATION ZONING ASSESSOR'S TAX/PARCEL # $ 149,000 7204800095 - TYPE OF PERMIT CK BUILDING 19 PLUMBING ® MECHANICAL ❑ DEMOLITION ❑ ENGINEERING ❑ FIRE PREVENTION NAME OF PROJECT AVANA -STAR LAKE APARMTMENTS- LIMITED AMENITIES REMODEL PROJECT DESCRIPTION Detailed description of work to Lease offire/rommunit17 building limited interior (nnl3;) remodeling Remodel exterior pool gate and BBQ be included on this permit only NAME PRIMARY PHONE Avana Star Lake Apartments -C/O Greystar 408-209-9616 PROPERTY OWNER MAILING ADDRESS 450 Sansome Street E-MAIL bgiffin@greystar.com CITY San Francisco STATE Ca ZIP 94111 NAME TBD PHONE MAILING ADDRESS E-MAIL CONTRACTOR CITY STATE ZIP FAX WA STATE CONTRACTOR'S LICENSE # EXPIRATION DATE UBI # NAME Charles Pick, Architect PRIMARY PHONE 415-233-3778 APPLICANT MAILING ADDRESS 2130 Fourth Street, Suite B E-MAIL cpick@basisarch.com CITY San Rafael STATE Ca ZIP 94901 FAX PROJECT CONTACT NAME Robert Mackey -Project Manager PRIMARY PHONE 415-302-2914 MAILING ADDRESS 2130 fourth Street, Suite B E-MAIL rmackey@basisarch.com (The individual to receive and respond to all correspondence CITY San Rafael STATE ZIP FAX concerning this application) Ca 94901 PROJECT FINANCING NAME Brian Giffin- Greystar ❑x OWNER -FINANCED When value is $5,000 or more (RCW 19.27.095) MAILING ADDRESS, CITY STATE, ZIP 450 Sansome St, fan Francisco, Ca 94111 ONE 408-209-9M I certify under penalty of perjury that I am the property owner or authorized agent of the property owner. I certify that to the best of my knowledge, the information submitted in support of this permit application is true and correct. I certify that I will comply with all applicable City of Federal Way regulations pertaining to the work authorized by the issuance of a permit. I understand that the issuance of this permit does not remove the owner's responsibility for compliance with local, state, or federal laws regulating construction or environmental laws. I further agree to hold harmless the City of Federal Way as to any claim (including costs, expenses, and attorneys' fees incurred in the investigation and defense of such claim), which may be made by any person, including the undersigned, and filed against the city, but only where such claim arises out of the reliance of the city, including its officers and employees, upon the accuracy of the information supplied to the city as apart of this application. SIGNATURE: DATE 10-4-2021 PRINT NAME: Charles Pick Bulletin #100 - February 19, 2020 Page 1 of 2 k:AHandouts\Permit Application MECHANICAL PERMIT Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existiggfixtures to remain. AIR HANDLING UNITS FANS GAS PIPE OUTLETS OTHER (Describe) AIR CONDITIONER FIREPLACE INSERTS HOODS (commercial) BOILERS FURNACES HOT WATER TANKS (Gas) COMPRESSORS GAS LOG SETS REFRIGERATION SYST DUCTING GAS PIPING WOODSTOVES PLUMBING PERMIT Indicate how many of each type offixture to be installed or relocated as part of this project. Do not include existing fixtures to remain. BATHTUBS (or Tub/shower combo) LAVS (Hand Sinks) TOILETS WATER PIPING DISHWASHERS RAINWATER SYSTEMS URINALS OTHER (Describe) DRAINS SHOWERS VACUUM BREAKERS DRINKING FOUNTAINS SINKS (Kitchen/Utility) WATER HEATERS (Electric) HOSE BIBBS SUMPS WASHING MACHINES TOTAL FIXTURES GENERAL INFORMATION CRITICAL AREAS ON PROPERTY? WATER PURVEYOR SEWER PURVEYOR VALUE OF EXISTING IMPROVEMENTS EXISTING/PREVIOUS USE LOT SIZE (In Square Feet( EXISTING FIRE SPRINKLER SYSTEM? PROPOSED FIRE SUPPRESSION SYSTEM? 36.9 Acres ❑ Yes ® No ❑ Yes X No RESIDENTIAL - NEW OR ADDITION AREA DESCRIPTION (in square feet) EXISTING PROPOSED TOTAL FOR OFFICE USE ............................................................................................................................... BASEMENT ............................................................................................................................... FIRST FLOOR (or Mobile Home) ............................................................................................................................... SECOND FLOOR ............................................................................................................................... COVERED ENTRY ............................................................................................................................... DECK ............................................................................................................................... GARAGE ❑ CARPORT ❑ ............................................................................................................................... OTHER (describe) ............................................................................................................................... Area Totals EXISTING PROPOSED TOTAL **NEW HOMES ONLY" LESTIMATED SELLING PRICE $ # OF BEDROOMS COMMERCIAL - NEW/ADDITION AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information NEW BUILDING ADDITION COMMERCIAL - REMODEL/TENANT IMPROVEMENTS AREA DESCRIPTION Area in Square Feet Occupancy Group(s) Construction Type # of Stories Additional Information TOTAL BUILDING TENANT AREA ONLY PROJECT AREA ONLY 6,143 SF B-2 V-A Bulletin #100 — February 19, 2020 Page 2 of 2 k:\Handouts\Permit Application AVANA�STAR LAKIE OWNER/CLIENT MECH/ELEC/PLUMBING ENGINEER AVANA STAR LAKE APARTMENTS ACIES ENGINEERING C/O GREYSTAR 400 N. McCRATHY BLVD 450 SANSOME STREET SUITE 250 LIMITED AMENITIES RLMODLL SANFRANC16 CA94111 95035 Brian Giffin Milan Pesakovic,PE A.C. AIR CONDITIONING LAM. LAMINATE 408 408-209-9616 PH: 408-522-5255 x123 PH:408-5 2- ACOUS. ACOUSTICAL LAV. LAVATORY bgiffinCgreystar.com email: milanCacies.net A. F. A.F.F. ADJUSTABLE ABOVE FINISH FLOOR MAT. MATERIAL COMMON BUILDING ARCHITECT MAX. MAXIMUM BASIS ARCHITECTURE Et CONSULTING INC ALUM. ALUMINIUM M.B. MACHINE BOLT 2130 4TH STREET, STE. B ANOD. B ANODIZED BOARD M.C. (M) MEDICINE CABINET MODIFIED 2211 S STAR LAKL ROAD SAN RAFAEL, CA 94915 Architect: Charles Pick BLDG. BUILDING MIN. MINIMUM . ' 415-233-3778 cpick@basisarch.com BLKG. BLOCKING MIR. MIRROR B BOTTOM M MISCELLANEOUS FLDLRAL WAY NG COUNTY WA 98003 BM.M. BEAM L. MTL. METAL CAB. CABINET CEM. CEM. CEMENT CERAMIC MTD. (N) N.I.C. MOUNTED NEW NOT CONTRACT PARCLL #7204800095 TEAM INDEX C.G. CORNER GUARDN0. NUMBEE R C.L. CENTER LINE CLG. CEILING NTE NOT TO EXCEED CLR. CLEARANCE N.T.S. NOT TO SCALE AT LEASE OFFICE/COMMUNITY BUILDING LIMITED INTERIOR (ONLY) REMODELING: CMU. CONCRETE MASONRY UNIT O.C. ON CENTER 1. ALL WORK SHALL CONFORM TO THE FOLLOWING BUILDING CODES AND WASHINGTON COL. COLUMN O.D. OUTSIDE DIAMETER STATE BUILDING CODE AMENDMENTS AND FEDERAL WAY MUNICIPAL CODES - BUILDING 1. REPLACE MILLWORK IN SOME LOCATIONS. ARCHITECTURAL CONC. CONCRETE O.H. OVER HEAD AND CONSTRUCTION, ADDITIONAL FEDERAL WAY REGULATIONS, AND NFPA STANDARDS. CONST. CONSTRUCTION PL. PLATE 2. REMOVE DECORATIVE PILASTERS. AO COVER SHEET CONTR. CONTRACTOR PLAM. PLASTIC LAMINATE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL FIRE CODE AO.1 SITE REFERENCE DIAGRAM AND LEASE OFFICE ACCESS PLAN REMOVE NON -BEARING PARTITIONS, DOORS, FINISHES AND REPLACE TO REMODEL SOME EXISTING OFFICES AS SHOWN. A2.0 EXISTING/DEMOLITION COMMON BUILDING PLAN C.T. C.T. CERAMIC TILE PLYWD. PLYWOOD 2018 INTERNATIONAL MECHANICAL CODE A2.OA EXISTING/DEMOLITION COMMON BUILDING POOL PLAN CTSK. COUNTERSINK PSI POUNDS/SQ. INCH 2O18 INTERNATIONAL FUEL GAS CODE 4. RELATED HVAC AND PLUMBING REVISIONS AS SHOWN. A2.1 COMMON BUILDING PLAN CTR. CENTER PT PRESSURE TREATED 2018 UNIFORM PLUMBING CODE A2.1A COMMON BUILDING POOL PLAN DA DISABLED ACCESSIBLE Q.T. QUARRY TILE 2020 NATIONAL ELECTRICAL CODE (NFPA 70) 5. REMODEL POOL GATE AND ADD OUTDOOR BBQ. A2.2 COMMON BUILDING RCP PLAN DBL. DOUBLE ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI 117.1) A5.0 DOOR Et WINDOW SCHEDULE D.F. DOUGLAS FIR R RISER 2018 INTERNATIONAL EXISTING BUILDING CODE A6.0 DETAILS DET. DETAIL (R) REPLACE WASHINGTON STATE AMENDMENTS SCOPE NOTE: A6.1 DETAILS -ACCESSIBILITY DIAG. DIAGONAL REINF. REINFORCING A6.2 DETAILS -ACCESSIBILITY DIA. DIAMETER REQ'D REQUIRED 2• THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS Et SHALL NOTIFY THE a ALL WORK IS INTERIOR REMODEL, EXCEPT POOL GATE, BBQ , DOORS AND WINDOW WORK. A6.3 DETAILS -PAVING ARCHITECT OF ANY DIMENSIONS Et CONDITIONS, WHICH DIFFER FROM THOSE SHOWN, DIM. DIMENSION REV. REVISED BEFORE STARTING WORK. DIMENSIONS GIVEN AS (CLR.) ARE CODE REQUIRED Et SHALL BE 0 NO CHANGE TO EXISTING OCCUPANCIES, OCCUPANT LOAD, EXITS, OR RATED ASSEMBLIES. MECHANICAL DN. DOWN RM. ROOM MAINTAINED. MO.1 MECHANICAL LEGEND, GENERAL NOTES Et EQUIPMENT SCHEDULE DR. DOOR RO. ROUGH OPENING NO STRUCTURAL ALTERATIONS EXCEPT (N) SECTIONAL DOOR Et OPENING. MO.2 MECHANICAL SPECIFICATIONS DWG. DRAWING RWL RAIN WATER LEADER 3. ALL DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD. ALL DIMENSIONS MO.3 MECHANICAL WSEC FORMS Et LOAD CALCS D.S. DOWNSPOUT FROM EXISTING CONSTRUCTION ARE FROM FACE TO FINISH, UNLESS OTHER WISE NOTED M1.1A MECHANICAL DEMO FLOOR PLAN COMMON BLDG- PART A SAD SUPPLY AIR DUCT (U.O.N.). M1.113 MECHANICAL DEMO FLOOR PLAN COMMON BLDG- PART B (E) EXISTING SCHED. SCHEDULE M2.1A MECHANICAL NEW FLOOR PLAN COMMON BLDG- PART A EA. EACH SEC. SECTION 4. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED M2.1 B MECHANICAL NEW FLOOR PLAN COMMON BLDG- PART B ELEC. ELECTRICAL SHT. SHEET DIMENSIONS. DIMENSIONS FOR EXISTING CONDITIONS Et ELEVATIONS MAY BE M6.1 MECHANICAL DETAILS APPROXIMATE. E.P. ELECTRICAL PANEL S&P SHELF AND POLE ELEV. BUILDING ELEVATION SL SKYLIGHT 5. ALL INSTALLATIONS TO BE IN ACCORDANCE WITH BEST INDUSTRY STANDARDS Et PLUMBING EQ. EQUAL SIM. SIMILAR MANUFACTURER'S REQUIREMENTS, SEE ATTACHED SPECIFICATIONS. POA PLUMBING LEGEND, GENERAL NOTES, CALCS Et SCHEDULES EXP. EXPOSED SPEC. SPECIFICATION P2.0 COMMON BUILDING - DEMO PLUMBING PLAN EXT. EXTERIOR SQ. SQUARE 6. ALL THE DRAWINGS SHOW REPRESENTATIVE Et TYPICAL ATTACHMENTS, CONNECTIONS, P2.OA COMMON BUILDING POOL AREA -DEMO PLUMBING PLAN F.FLR. FINISH FLOOR S.S.. TAINLESS STEEL FASTENINGS Et ETC. SHALL BE PROPERLY SECURED IN CONFORMANCE WITH BEST SCOPE 0 F WORK SUMMARY P2.1 COMMON BUILDING - PROPOSED PLUMBING PLAN PRACTICE. FLASH FLASHING S.S.D. SEE STRUCT. DRAWINGS P2.1A COMMON BUILDING POOL AREA- PROPOSED PLUMBING PLAN P6.1 PLUMBING DETAILS F.O.F. FACE OF FINISH S.M.D. SEE MECH. DRAWINGS 7. THE PLANS MAY OR MAY NOT BE BASED ON A SURVEY Et ARE INTENDED ONLY TO SHOW F.O.S. FACE OF STUD STD. STANDARD GENERAL LAYOUT OF PROPERTY Et WORK LOCATIONS. CONDITIONS SHOWN INTERIOR DESIGN Et FINISH SHEETS (SHOW DESIGN INTENT Et FINISH/FIXTURE FR.C. FRENCH CASEMENT STL. STEEL APPROXIMATE. SELECTIONS ONLY - IN CASE OF CONFLICT, DEFER TO A,M,E,P SHEETS) EXISTING APARTMENT BUILDINGS = 72 (2-STORY Et 3-STORY) - NO CHANGE FTG. FOOTING STOR. STORAGE 8. ALL WORK TO BE PAINTED TO MATCH (E), UNLESS OTHERWISE NOTED. 2.0 FLOOR FINISHES FX. FIXED STRUCT. STRUCTURAL CONSTRUCTED: 1987 (PHASE 1), 1989 (PHASE II) 3.0 WALL FINISHES GA. GAUGE SUSP. SUSPENDED 9. ALL WORK SUBJECT TO ASSOCIATED PROJECT MANUAL SPECIFICATIONS AND LOT SIZE: 36.9 ACRES 3.2 INTERIOR ELEVATIONS GALV. GALVANIZED T.B. TOWEL BAR INSTRUCTIONS BY ARCHITECT. OCCUPANCY: B-2 3.3 INTERIOR ELEVATIONS GL. GLASS T.O.S. TOP OF SLAB CONSTRUCTION TYPE: TYPE V-A (NOWSPRINKLERED) 6.0 FINISH SPECIFICATIONS 10. ALL CONDITIONS ARE EXISTING UNLESS OTHERWISE NOTED. GR. GRADE TGL. TEMPERED GLASS GWB. GYPSUM WALL BOARD TEtG TONGUE AND GROOVE HAZARDOUS MATERIALS IN EXISTING CONSTRUCTION TOTAL UNITS = 750 UNITS (616,740 SF - NO CHANGE) GYP. GYPSUM TYP. TYPICAL BASIS ARCHITECTURE Et CONSULTING ASSUMES NO RESPONSIBILITY FOR THE MANAGEMENT OF H.A.R. HOT AIR REGISTER U.B.C. UNIFORM BUILDING CODE HAZARDOUS MATERIALS THAT MAY BE ON SITE. THE CONTRACTOR SHALL BE RESPONSIBLE TYPE 1: 1 BED/1 BATH = 584 SF (122 UNITS) FOR INSURING THAT PERSONNEL WITHIN THE WORK AREA ARE PROTECTED FROM EXPOSURE TYPE 2: 1 BED/1 BATH = 640 SF (188 UNITS) HDR. HEADER U.O.N. UNLESS OTHERWISE NOTED TO HAZARDOUS MATERIALS. IF MATERIALS ARE DISCOVERED THAT MAY BE HAZARDOUS, THE TYPE 3: 2 BED/1 BATH = 788 SF (64 UNITS) HGR. HANGER V.G. VERTICAL GRAIN CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND CEASE WORK UNTIL CONDITIONS TYPE 4: 2 BED/1 BATH = 866 SF (48 UNITS) HDWD. HARDWOOD VERT. VERTICAL CAN BE MAINTAINED IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS. TYPE 5: 2 BED/1 BATH = 912 SF (84 UNITS) HORZ. HORIZONTAL TYPE 6: 2 BED/2 BATH = 970 SF (112 UNITS) HT. HEIGHT V.I.F. VERIFY IN FIELD TYPE 7: 3 BED/2 BATH = 1,037 SF (72 UNITS) HVAC. HEATING, VENTILATING W/ WITH TYPE 8: 3 BED/2 BATH = 1,221 SF (60 UNITS) INT. INTERIOR WC WATER CLOSET INST. INSTALLATION WD. WOOD LEASE OFFICE/COMMUNITY BUILDING = 6,143 SF (1-STORY) - NO CHANGE INSUL. INSULATION W•P. WATERPROOF GENERALNOTES, CODE INFO INDOOR POOL BUILDING - 3,759 SF (1-STORY) - NO CHANGE CABANA BUILDING = 1,954 SF (1-STORY) - NO CHANGE 1. BANQUETTE SEATING PARKING = 1,262 PARKING SPACES (INC. 21 ADA SPACES) - NO CHANGE 2. SIGNAGE AND GRAPHICS PACKAGE EXTERIOR PARKING LOT = 950 - OPEN SPACES 176 - CARPORT SPACES 136 - DETACHED GARAGE SPACES ABBREVIATIONS DEFERRED SUBMITTALS PROJECT DATA SHEET INDEX Safeway .. '.' a Murphy's I Take` 'N J' . Bake... Little Caesars, Pi=a y S 272nd St S 272nd St S 272nd-St S 272nd St ^' S 273r�d^S- ,. :; •. _' dRd EmeCu�ireha sfa. �a,��, k-Twain C'. ub Palisadzs`I,-J Rol Elementary School`�� .. t I.. .. Ar - Avana r Lake r. 4 Ias ...� -� s 276th Si r 6 T UnEarthetl skin care studio i,,� 500 feet PROJECT LOCATION O PHOTO - EXISTING CONDITIONS VICINITY MAP NORTH BASISArchitecture &Consulting 0 2130 FOURTH ST SAN RAFAEL, CA 94901 PHONE (415) 457-6035 CHARLES PICK, ARCHITECT �252 FEGISTERED RCHITECT IHAR �ICK STATE OF WASHINGTON ■�■�■�■�■�■ DESIGNATED PATH OF TRAVEL PAVING IMPROVEMENTS a a (N) CONCRETE (V.I.F.) i (N) GRADING (E) WALL TO REMAIN (E) WALL TO BE REMOVED (N) INTERIOR PARTITION (N) 1 HOUR RATED WALL PERMIT #21-104204 DRAWING REVISION LOG FOR ISSUE 9-22-2021 RESUBMITTE 11 16 2 21 ITY OF FEDERAL WAY MMUNITY DEVELOPMENT PROJECT NAME: AVANA STAR LAKE LIMITED AMENITIES REMODEL PROJECT LOCATION: 2211 S. STAR LAKE RD., FEDERAL WAY, KING COUNTY, WA 98003 SHEET TITLE: COVER SHEET Copyright 2021 by Charles Pick, Architect and Basis Architecture Et Consulting Inc. SITE KEYED NOTES O ACCESSIBLE PARKING: PROVIDE CONFORMING ACCESSIBLE VAN PARKING STALL WITH LEVEL ASPHALT SURFACE NTE 1.9% SLOPE IN ANY DIRECTION, WITH CONFORMING STRIPPING, SYMBOL Et SIGNAGE. kCCESSIBLE CURB CUT RAMP: PROVIDE CONFORMING ACCESSIBLE CURB CUT RAMP W/ ►ETECTABLE DOMES. kCCESSIBLE PATH OF TRAVEL: PROVIDE FROM COMMON BUILDING TO ACCESSIBLE VAN 'ARKING SPACES Et PUBLIC RIGHT OF WAY.REPLACE WALKWAYS AS REQUIRED TO 'ROVIDE CONFORMING PATH OF TRAVEL NOT TO EXCEED 4.9% SLOPE IN DIRECTION OF -RAVEL AND CROSS SLOPE NOT TO EXCEED 1.9% AND PROVIDE LEVEL NTE 1.9% SLOPE ANY DIRECTION AT WALK INTERSECTIONS. NOTE: REMOVE ALL NON -CONFORMING ;AMPS. :OMMON BUILDING ENTRY LANDING: PROVIDE LEVEL LANDING FLUSH W/FINISH FLOOR IT, NTE 1.9% SLOPE IN ANY DIRECTION, 60" MINIMUM FROM ENTRY DOOR SURFACE. VHEEL STOPS -ACCESSIBILITY: PROVIDE NEW DOWEL -SET CONCRETE WHEEL STOPS AT kLL PARKING SPACES ALONG ACCESSIBLE PATH OF TRAVEL. 'EDESTRIAN GATE -ACCESSIBLE: PROVIDE ACCESSIBLE PEDESTRIAN GATE WITH 10" TOE JCK PANEL, LEVEL HARDWARE W/RETURNS AND LEVEL LANDING NTE 1.9% SLOPE IN kNY DIRECTION. SEE DETAIL#1 THIS SHEET. kCCESS - SIGNAGE DIRECTIONAL: PROVIDE NEW DIRECTIONAL SIGNAGE. (DEFERRED ,UBMITTAL - WORK BY OTHERS) ;EMOVE FLATWORK IN CIRCULAR AREA AT PLANTER, REPLACE W/(N) CURB. 'INE GRADE (E) OR (N) LANDSCAPE FLUSH TO TOP OF PAVING. ,EE SHEET A6.1 FOR ACCESSIBLE DETAILS (E)FENCE SHWON APPRO) (N)MTL PEDESTRIAN GA_ LEVER HARDWARE b RETU RI 10" MTL KICK PAN 60" MIN oe (N)LEVEL LDG NTE 1.9% SLOPE IN ANY DIRECTION PEDESTRIAN GATE SCALE:a' = V-0" SITE REFERENCE DIAGRAM Et LEASE OFFICE ACCESS PLAN (MAY BE SHOWN APPROX., SEE DIMENSIONS FOR CODE) SCALE: NTS NORTH BASIS Architecture &Consulting Ci 2130 FOURTH ST SAN RAFAEL, CA 94901 PHONE (415) 457-6035 CHARLES PICK, ARCHITECT 9252IREGISTERED ARCHITECT HAR �ICK STATE OF WASHINGTON ����������■ DESIGNATED PATH OF TRAVEL PAVING IMPROVEMENTS a a (N) CONCRETE (V.I.F.) (N) GRADING (E) WALL TO REMAIN (E) WALL TO BE REMOVED ,777777 (N) INTERIOR PARTITION (N) 1 HOUR RATED WALL DRAWING REVISION LOG FOR ISSUE 9-22-2021 RESUBMITTE 11 16 2 21 ITY OF FEDERAL WAY MMUNITY DEVELOPMENT PROJECT NAME: AVANA STAR LAKE LIMITED AMENITIES REMODEL PROJECT LOCATION: 2211 S. STAR LAKE RD., FEDERAL WAY, KING COUNTY, WA 98003 SHEET TITLE: SITE REFERENCE DIAGRAM Copyright 2021 by Charles Pick, Architect and Basis Architecture Et Consulting Inc. AO* 1